0
Transcript of US Nuclear Regulatory Commission
.__. --- ,.._;r--·--, _, ~
' ,, Commonwea~dison . .;__.
\ .,
One First Nationa~. Chicago, Illinois Address Reply to: Post Office Box 767 Chicago, Illinois 60690
May 19, 1983
Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washinton, D.C .. 20555
Subject: Dresden Station, Units 2 and-3 . Quad Cities Station, Units 1 and 2 Ninety Day Response to Final Rule 10CFR50.49 on Environmental Qualification uf Electrical N RC · Docket - No s ~ · 5 0- 2 3 7 I 2 4 9 and·· ·5 0 - 2 5 4 I 2 6 5 - · ·
Equipment
R e f e re n c e : ( a ) B • Ry b a k Let t e r t o H • R • De n t o n· d at e d A p r i 1 4 , 1 9 8 3 • ( b ) D . B • Va s s a 1 1 o Lett e r t o D .. · L . , Ear r a r d ate d A p r i 1 8 , 1 9 8 3 •
Dear Mr. Denton: J
. Enclosed for your review a~e ten (10) copies of the revised environme~tal qualification report in ~upport of Dresden and Quad Cities Station response to I.E. Bulletin 79-0lB.'. In accorda~ce with 10CFR50.49, the report contai~s the following:.
I) Identification of all equipment included in the Qualification Program located in harsh environments •.
II) Equipment characteristics and the environmental conditions to which ft is subjected.
III) MethodologJ an~ guidelin~s used t-0 evaluate and qualify the equipment. . '
IV) Present qualification status.
As requested in Reference (b), all items in NRC Categories I.b, II.a, and IV have been addressed. The justification for continued operat1on of these items has been reviewed and are current for these categories as well as all other outstanding items. It should be noted that one item exists in Categdry IV (Dresden 2 only). This item, FRC number 102, are valve position switches. The position switches have no part in the control function or circuitry of the isolation valves. The switches only provide supplemental .indication and operator action is not required. Therefore, the position switches have been deleted from the environmental qualifi~ation program. ·
.·,
This revised Environment.al Qualification Report is the latest updated report. The report is current as of ·May 20, 1983 and supercedes the original environmental qualification report dated November 1, 1980. It provides compliance with 10CFR50.49 paragraphs (a) and (b). As a clarification to paragraph (b) 2, attachment 1 contains a description of ~ethodology used to address non-safety related electrical equipment for ' th0nvi_r:onm:nta 1 Qua 1 if icat_ion:. Program. AO"f ·r 8305250377 B305T9-- . · ~ J O I PDR ADOCK 05000237 ( . • 0 f:)\~'j I I I G PDR ' «i-•""lf«- '
- --- -· --------L..
·,
- 2 -
As a summary for each unit, three lists of equipment have been included for your use. The lists are divided as follows:
I) Equipment required to be qualified persuant to 10CFR50.49. II) Equipment that is currently qualified.
III) Equipment that is not presently qualified and its schedule for qualification or replacement.
Dresden Unit 3 is tentatively scheduled for an outage in Spring, 1985. The outage coincides with the second refueling outage , beginning after March 31, 1982. The qualification dates for the Dresden 3 outstanding items reflect the scheduled end date of the unit outage.
Reference (a) has responded to all outstanding issues of the technical evaluation report. In addition, ten (10) copies of the Qualification Documentation for the electrical penetrations is submitted for your review.
This response outlines existing plant equipment presently requ1r1ng qualification. B~sed on the final resolution with the Commission on Regulatory Guide 1.97, NUREG 0737 and other regulatory guidance, additional equipment may be identified requiring review. If this additional equipment requires upgrading, a supplement to this response will be provided.
To the best of my knowledge and belief the statements contained herein and in the attachment are true and correct. In some respects these statements are not based on my persoanl knowledge but upon information furnished by other Commonwealth Edison employees and \ contractor employees or consultants. Such information has been reviewed in accordance with Company practice and I believe it to be reliable.
If you have any questions, please contact this office. One signed original and sixty copies of this letter and this attachment are provided for your use. Due to the size of the reports only ten copies are enclosed.
BMV/bmb/3097D Attachments cc: NRC Resident Inspector - Dresden
NRC Resident Inspector - Quad Cities R. Gilbert - NRR R. Bevan - NRR
Very truly yours,
B • Nuclear Licensing Administrator
\ ,
- ... _ ,. "\. .
~ ' ~ .
ATTACHMENT l
DESCRIPTION OF METHODOLOGY USED TO ADDRESS NON-SAFETY RELATED
ELECTRICAL EQUIPMENT FOR THE ENVIRONMENTAL QUALIFICATION PROGRAM
AT DRESDEN AND QUAD CITIES STATIONS
.... '
1.0 INTRODUCTION
10 CFR 50.49 includes in its scope nonsafety-related electrical equipment whose failure under postulated harsh environment conditions could prevent satisfactory accomplishment of a safety function. The possibility of failure of nonsafety-related equipment in a manner detrimental to safety has been evaluated by a combination of the following methods.
a. Review for system-specific failure effects undertaken during development of the CECo response to NRC Bulletin 79-0lB (and subsequent environmental qualification-related submittals)
b. Review of plant design criteria which.otherwise prev~hts (or limits) undesirable nonsafety-related equipment failure effects · ··-
The methodology for review for system-specific failure effects is described in section 2.0, the relevant plant design criteria are described in Section ,J.O, and the results of including or excluding equipment from environmental qualification . requirements based on Items a and b above are summarized in. Section 4.0.
2.0 REVIEW AND DEVELOPMENT OF THE LIST OF EQUIPMENT (SYSTEM COMPONENTS REQUIRING ENVIRONMENTAL QUALIFICATION)
The review conducted to identify equipment requiring environmental qualification was not limited to safety-related system components. Components required to operate, or whose potential failure would affect plant safety, were identified for review using the following methodology.
2.1 In order to identify equipment important to safety, essential safety functions were determined based on Section 3 of the DOR Guidelines. These functions are a~ follows.
a. Achieve reactor shutdown b. Achieve containment isolation c. Ensure reactor core cooling d. Provide containment heat removal e. Prevent the release of radioactive material in excess
of the guidelines of 10 CFR 100
-1-
.. ~ -· ' . .. ,,
-~lant systems we.reviewed to identify tho.essential for (or potential for a failure affecting) any of the safety functions in Section 2.1.
- ·• '
2.3 Piping and instrumentation diagrams for each of the systems identified in Section 2.2 were reviewed to identify system components essential to the performance of the system's safety function or whose failure would affect performance of the system's safety function.
2.4 The entire instrument loop associated with each instrument identified in Section 2.3 was reviewed to identify any other components whose functions were essential or whose failures could adversely affect operation of the instrument loop.
2.5 The resultant component list was compared with the NSSS vendor (General Electric) reports for completeness.
2.6 The environme~tal qualification equipment list submitted with the origirial CECo response to NRC Bulletin 9-0lB has been revised and ripdated on a continuing basi~t~ reflect plant design changes and hew information.··
3.0 RELEVANT CECO PLANT DESIGN CRITERIA
Plant design criteria preventing or limiting failure eff~cts in nonsafety-related electric equipment are summarized below.
3.1 The CECo plant design is in compliance with IEEE Standard 279-1971. Therefore. nonsafety-related equipment connected to protection systems (as defined in IEEE Standard 279-1971) are separated by approved isolation devices. No credible failure at the output of an isolation device will prevent the associated protection system channel from meeting the minimum performance requirements specified in the plant's design bases.
3.2 If a LOCA mitigation initiation signal occurs. nonessential electrical loads are deenergized or transferred to the startup transformer (offsite power supply system). Therefore. failure of nonsafety-related electrical equipment is prevented from affecting safety-related electrical equipment.
3.3 Coordinated electrical fault protection (in the form of circuit breaker~ and fuses) is included in the plant design for low voltage power cables in the cont~ol room. Therefore. harsh environment induced failures producing high current in nonsafety-related equipment will be
-2-
• - \.1::·....-..· ~ • ··.',,; 4 ••
• !: -~·· /? '·
4.0
prevented from a8ecting other electrical l.s supplied by the same electrical bus.
CONCLUSIONS
As described in Section 2.0. the scope of the system review effort has included nonsafety-related equipment. Potential failures affecting performance'of system safety functions were investigated on a system and instrument loop basis. Although the nonsafety-related equipment within the scope of Paragraph b(2) of 10 CFR 50.49 has not been uniquely identified in the IE Bulletin 79-0lB response. nonsafety-related equipment with potential for a failure (in a manner detrimental to safety) has been included in the CECo environmental qualification program.
-3-
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT
TO 10 CFR PART 50.49
-------------
- NOTICE~ THE ATTACHED FILES ARE OFFICIAL RECORDS OF THE DIVISION OF DOCUMENT CONTROL. THEY HAVE BEEN CHARGED TO YOU FOR A LIMITED TIME PERIOD AND c
MUST BE RETURNED TO THE RECORDS FACILITY BRANCH 016. PLEASE DO NOT SEND DOCUMENTS CHARGED OUT THROUGH THE MAIL. REMOVAL OF ANY PAGE(S) FROM DOCUMENT FOR REPRODUCTION MUST BE REFERRED TO FILE PERSONNEL.
DEADLINE RETURN DATE
RECORDS FACILITY BRANCH
REGWA IDRV DOCKET flLE COPY
PAGE 001.
COMMONWEALTH EDISON COMPANY
QUAD CITIES UNIT 1
LIST OF EQUIPHENT··REQUIRED· TO ·BE; QUAl.:IFIED PURSUAN~ TO 10 CFR PART· 50.49 FOR QUAD CITIES 1
DATE OF ISSUE 05-18-1983
REGULATORY DOCKET FILE COPY
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 002.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES
SYSTEM : REACTOR PROTECTION
PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------TE-1-1291-60A TE-1-1291-60B TE-1-1291-60C TE-1-1291-60D TE-1-1291-60E TE-1-1291-60F TE-1-1291-60G TE-1-1291-60H
TEMPERATURE ELEMENT TEMPERA~URE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 003.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 1
SYSTEM : CORE SPRAY
PLANT IDENTIFICATION NUMBER
FS-1-1464A FS-1-14648 FT-1-1461A FT-1-14618 M0-1-1402-24A M0-1-1402-248 M0-1-1402-25A M0-1-1402-258 M0-1-1402-38A H0-1-1402-388 M0-1-1402-4A H0-1-1402-48 PT-1-1460A PT~-1460B
1-1401A 1-14018
GENERIC NAME
FLOW SWITCH FLOW SWITCH FLOW TRANSMITTER FLOW TRANSMITTER MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GLOBE VALVE MOTOR OPERATED GLOBE VALVE PRESSURE TRANSMITTER PRESSURE TRANSMITTER PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN
e
COHHONWEALTH EDISON COHPANY 05-18-1983 PAGE 004.
LIST OF EQUIPHENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 1
SYSTEH : HIGH PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUMBER GENERIC NAHE
DPIS-1-2352 DIFFERENTIAL PRESSURE INDICATING SWITCH DPIS-1-2353 DIFFERENTIAL PRESSURE INDICATING SWITCH LS-1-2351A LEVEL SWITCH LS-1-2351B LEVEL SWITCH H0-1-2301-35 MOTOR-OPERATED GATE VALVE M0-1-2301-36 HOTOR-OPERATED GATE VALVE M0-1-2301-4 MOTOR-OPERATED GATE VALVE H0-1-2301-5 MOTOR-OPERATED GATE VALVE M0-1-2301-8 HOTOR OPERATED GATE VALVE PS-1-23B9A PRESSURE SWITCH (LOW> PS-1-23B9B PRESSURE SWITCH (LOW> PS-1-2389C PRESSURE SWITCH (LOW> PS-1-2389D PRESSURE SWITCH (LOW> TS-1-2370A TEMPERATURE SWITCH TS-1-2370B TEHPERATURE SWITCH )S-1-2370C TEHPERATURE SWITCH TS-1-2370D TEHPERATURE SWITCH TS~-2371A TEMPERATURE SWITCH TS-1-2371B TEMPERATURE SWITCH TS-1-2371C TEMPERATURE SWITCH TS-1-2371D TEHPERATURE SWITCH TS-1-2372A TEMPERATURE SWITCH TS-1-2372B TEMPERATURE SWITCH TS-1-2372C TEHPERATURE SWITCH TS-1-2372D TEMPERATURE SWITCH TS-1-2373A TEHPERATURE SWITCH TS-1-2373B TEHPERATURE SWITCH TS-1-2373C TEMPERATURE SWITCH TS-1-2373D TEHPERATURE SWITCH
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR
SYSTEM : AUTO DEPRESSURIZATION/ HAIN STEAM
PLANT IDENTIFICATION NUMBER
1-203-3A 1-203-3B 1-203-3C 1-203-3D 1-203-3E 1-261-60A 1-261-60B 1-261-60C 1-261-60D 1-261-60E 1-262-61A 1-262-618 1-262-61C 1-262-61D 1-~2-61E
GENERIC NAME
SAFETY RELIEF VALVE AND SOLENOID ELECTROMATIC RELIEF VALVE AND SOLENOID ELECTROMATIC RELIEF VALVE AND SOLENOID ELECTROMATIC RELIEF VALVE AND SOLENOID ELECTROHATIC RELIEF VALVE AND SOLENOID SENSOR- ACOUSTIC MONITOR SENSOR- ACOUSTIC MONITOR SENSOR- ACOUSTIC MONITOR SENSOR- ACOUSTIC MONITOR SENSOR- ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR
PAGE 005.
QUAD CITIES 1
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 006.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES
SYSTEM : RESIDUAL HEAT REMOVAL
PLANT IDENTIFICATION NUMBER
DPIS-1-1001-81A DPIS-1001-BlB DPS-1-1001-78A DPS-1-1001-78B FT-1-1042A FT-1-10428 FT-1-1049A FT-1-10498 FT-1-1051A FT-1-1051B LS-1-4941-2A LS-1-4941-2B LS-1-4941-2C M0-1-1001-16A M0~-1001-16B
M0-1-1001-18A M0-1-1001-188 M0-1-1001-185A M0-1-1001-185B M0:-1-1001-19A M0-1-1001-19B M0-1-1001-21 M0-1-1001-23A M0-1-1001-23B M0-1-1001-26A M0-1-1001-26B H0-1-1001-28A M0-1-1001-28B M0-1-1001-29A M0-1-1001-29B M0-1-1001-34A M0-1-1001-34B M0-1-1001-36A M0-1-1001-368 H0-1-1001-37A M0-1-1001-37B M0-1-1001-4A M0-1-1001-4B M0-1-1001-47 H0-1-1001-5A M0-1-1001-5B M0-1-1001-50 M0-1-1001-60 M0-1-1001-63 M0-1-1001-7A M0-1-1001-7B M0-1-1001-7C M0-1-1001-7D PT-1-1043A PT-1-1043B PT-1-1044A PT-1-1044B 1-1001-65A 1-1001-65[1 1-1001-65C 1-1001-65D 1-1002A 1-1002B 1-1002C 1-1002D 1-5745A 1-57458 1-5745C 1-5745D
GENERIC NAME
DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE SWITCH DIFFERENTIAL PRESSURE SWITCH FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER LEVEL SWITCH (HIGH) LEVEL SWITCH (HIGH> LEVEL SWITCH (HIGH> MOTOR-OPERATED GLOBE VALVE MOTOR-OPERATED GLOBE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GLOBE VALVE MOTOR-OPERATED GLOBE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GLOBE VALVE MOTOR-OPERATED GLOBE VALVE MOTOR-OPERATED GLOBE VALVE MOTOR-OPERATED GLOBE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GLOBE VALVE MOTOR-OPERATED GLOBE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE-VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE PRESSURE TRANSMITTER PRESSURE TRANSMITTER PRESSURE TRANSMITTER PRESSURE TRANSMITTER RHR SERVICE WATER PUMP MOTOR-DRIVEN RHR SERVICE WATER PUMP MOTOR-DRIVEN RHR SERVICE WATER PUMP MOTOR-DRIVEN RHR SERVICE WATER PUMP MOTOR-DRIVEN PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN ROOM COOLER (FAN MOTOR> ROOM COOLER <FAN MOTOR) ROOM COOLER <FAN MOTOR> ROOM COOLER (FAN MOTOR>
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 007.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES
SYSTEM : PRESSURE SUPPRESSION --------------------------------------------------
PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------LT-1-1641-5A LT-1-1641-5B PS-1-1622A PS-1-16228 PT-1-1625 PT-1-1641-6A PT-1-1641-6B S0-1-1601-50A S0-1-1601-508
LEVEL TRANSMITTER LEVEL TRANSMITTER PRESSURE SWITCH PRESSURE SWITCH PRESSURE TRANSMITTER PRESSURE TRANSMITTER PRESSURE TRANSMITTER SOLENOID VALVE SOLENOID VALVE
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 008.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 1
SYSTEM : STANDBY GAS TREATMENT
PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------FSL-1/2-7541-33A FSL-1/2-7541-338 FSL-112-7541-8A FSL-112-7541-88 M0-1/2-7504A M0-112-7504B H0-1/2-7505A M0-1/2-7505B M0-1/2-7507A M0-1/2-7507B TSH-1/2-7541-llA TSH-1/2-7541-llB 112-7503A 112-75038 1/~-7506A
112-7506B 2212-29A 2212-29B
FLOW SWITCH LOIJ FLOW SWITCH LOW FLOW SWITCH LOW FLOW SWITCH LOIJ HOTOR OPERATED DAMPER MOTOR OPERATED DAMPER HOTOR OPERATED DAMPER MOTOR OPERATED DAMPER MOTOR OPERATED DAMPER MOTOR OPERATED DAMPER TEM~ERATURE SWITCH HIGH TEMPERATURE SWITCH HIGH ELECTRIC AIR HEATER ELECTRIC AIR HEATER MOTOR-EXHAUST FAN MOTOR-EXHAUST FAN LOCAL CONTROL PANEL LOCAL CONTROL PANEL
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 009.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 1
SYSTEM : SERVICE WATER -------------------------~----------------------
PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------1-5746A 1-5746B 1-5748A 1-5748B
ROOM COOLER FAN MOTOR ROOM COOLER FAN MOTOR ROOM COOLER FAN MOTOR ROOM COOLER FAN MOTOR
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 010.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 1
SYSTEM : CONTAINMENT ISOLATION --------------------------------------------------
.PLANT IDENTIFICATION NUM8ER GENERIC NAME ----------------------~------------------------------------------------------------------------~--HCl-1-1201-2 H0-1-1201-5 M0-1-220-1 M0-1-220-2 H0-1-3702 M0-1-3703 H0-1-3706 S0-1-203-18 S0-1-203-lC S0-1-203-lD S0-1-203-2A S0-1-203-28 S0-1-203-2C S0-1-203-2D S0-1-203-lA TS-1-261-15A TS-11-261-158 TS-1-261-15C TS-1-261-15D TS-1-261-16A TS-1-261-16B TS-1-261-16C TS-1-261-16D TS-i-261-17A TS-1-261-17B TS-1-261-17C TS-1-261-17D TS-1-261-18A TS-1-261-188 TS-1-261-18C TS-1-261-18D
MOTOR OPERATED GATE VALVE HOTOR OPERATED GATE VALVE HOTOR OPERATED GLOBE VALVE HOTOR OPERATED GLOBE VALVE MOTOR OPERATED VALVE HOTOR OPERATED GATE VALVE HOTOR-OPERATED GATE VALVE KSIV AND SOLENOI0--FOR AIR OPERATOR KSIV AND SOLENOID FOR AIR OPERATOR HSIU AND SOLENOID FOR AIR OPERATOR HSIV AND SOLENOID FOR AIR OPERATOR HSIV AND SOLENOID FOR AIR OPERATOR HSIU AND SOLENOID FOR AIR OPERATOR HSIU AND SOLENOID FOR AIR OPERATOR HSIV AND SOLENOID FOR AIR OPERATOR TEMPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEMPERATURE SWITCH TEHPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH
•
COMHOHWEALTH EDISON COHPANY 05-18-1983 PAGE 011.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES
SYSTEM : REACTOR RECIRCULATION
PLANT IDENTIFICATION HUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------A0-1-220-44 LIS-1-263-58A LIS-1-263-58B LITS-1-263-73A LITS-1-263-73B M0-1-202-5-A H0-1-202-5-B POS-1-220-44 PT-1-662
SOLENOID VALVE LEVEL INDICATOR SWITCH LEVEL INDICATOR SWITCH LEVEL INDICATING TRANSHITTER SWITCH LEVEL INDICATING TRANSMITTER SWITCH HOTOR OPERATED GATE VALVE&BRAKE MOTOR OPERATED GATE VALVE&BRAKE POSITION SWITCH PRESSURE TRANSMITTER
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR
SYSTEM : PROCESS RADIATION MONITORING
PLANT IDENTIFICATION NUMBER
RE-1-1735A RE-1-17358
GENERIC NAME
RADIATION ELEMENT GM TUBE RADIATION ELEMENT GM TUBE
PAGE 012.
QUAD CITIES 1
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 013.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 1
SYSTEM : STANDBY AC POWER
PLANT IDENTIFICATION NUMBER
HCC 18-lA HCC 18-lB HCC 18-3 HCC 18/19-5 i'!CC 19-1 HCC 19-3 HCC 19-6
GENERIC NAME
480 V MCC 480 V HCC 480 V HCC 480 V HCC 480 V HCC 480 V HCC '180 V HCC
1''
COHHONWEALTH EDISON COHPANY 05-18-1983 PAGE 014. i •'
LIST OF EQUIPHENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 1
SYSTEM : STANDBY DC POWER
PLANT IDENTIFICATION NUHBER GENERIC NAHE
125 V DCDP 1 125 V DC REACTOR BLDG DISTRIBUTION PANEL
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR
SYSTEM : REACTOR CORE ISOLATION COOLING
PLANT IDENTIFICATION NUMBER
M0-1-1301-16 M0-1-1301-17 TS-1-1360 15D TS-1-1360-14A TS-1-1360-14B TS-1-1360-14C TS-1-1360-14D TS-1-1360-15A TS-1-1360-15B TS-1-1360-15C TS-1-1360-16A TS-1-1360-168 TS-1-1360-16C TS-1-1360-16D TS-1-1360-17A TS-1-1360-178 TS-1-1360-17C TS-1-1360-17D
GENERIC NAME
MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH
PAGE 015.
QUAD CITIES 1
COHMONWEALTH EDISON COMPANY 05-18-1983 PAGE 016.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES
SYSTEM : GENERAL USE ELECTRICAL EQUIPHENT
PLANT IDENTIFICATION NUMBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE <SHIELDED> lX-lOOA 1X-100B 1X-100C lX-lOOD 1X-100E 1X-100F 1X-100G 1X-101A 1X-101B 1X-101D 1X-102A lX-103 1X-104B 1X-104C 1X-104F 1X-105A 1X-105B 1X-105C 1X-105D 1X-107A 79-01B-1 79-0lB-2 79-01B-3 79-01B-4 79-0lB-5 79-0lB-6 79-0lB-7 79-01B-8
GENERIC NAME
ANHYDREX XX PLASTEX INSU & JKT ANHYDREX XX PLASTEX INSU & JKT BUTYL RBR INSU POLYVN CHLORIDE JKT BUTYL RBR INSU POLYVN CHLORIDE JKT BUTYL RBR INSU POLYVN CHLORIDE JKT CROSSLINKED POLYOLEFIN W-16 AWG DRN & JKT CSPE INSUL.,POLYEST ALUMINUM SHLD. EPDM I INSUL. W/HAPAL COND. JKT EPDM I INSUL. W/HAPAL COND. JKT EPDM II INSUL. W/HAPA COND. JKT EPDM INSUL. W/HAPALON JKT DRN. AND SHLD. W/OVERALL EPR INSUL. CSPE JKT. EPR W/CSPE JKT., FR SHLD, DRN WIRE AND OVERALL CSPE JKT. EPR W/CSPE JKT., FR SHLD, DRN WIRE AND OVERALL CSPE JKT. EPR W/NEOPRENE INSUL. AND JKT. FR-EPDM AND 16 AWG AND HYPALON JKT. MULTI PAIR WITH OVERALL SH CU CON OKONITE EPR INSUL. WITH OKO COVER AND OVERALL OKO JKT POLY NYLON INSU SHLD & PLASTEX INSTR RBR INSU POLYV CHLORIDE JACKET SINGLE/MULTIPAIR CABLE WITH OVERALL SH SR INSUL. WITH GLASSBRAID AND SIL. SAT. ASBESTOS BRAIDED SWITCHBOARD-TYPE SIS tSI 57275 VULKENE XLPE INSUL. WITH NEOPRENE JKT. 3 TW WITH OVERALL SH EPR INSUL. EXTRUDED SEMI. COND. CSPE INSUL. SHLD, CSPE JK ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION TERMINAL BLOCKS <TYPICAL 2 UNITS) TERMINAL BLOCKS <TYPICAL 2 UNITS> TERMINAL BLOCKS <TYPICAL 2 UNITS> TERMINAL BLOCKS <TYPICAL 2 UNITS> TERMINAL BLOCKS <TYPICAL 2 UNITS) TERMINAL BLOCKS <TYPICAL 2 UNITS> TERMINAL BLOCKS <TYPICAL 2 UNITS) TERMINAL BLOCKS <TYPICAL 2 UNITS>
COMMONWEALTH EDISON COMPANY OS-18-1983
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR
SYSTEM. : CAM
PLANT IDENTIFICATION NUMBER
PT-1-2421-A PT-1-2421-B RE-1-2418-C RE-1-2418-D RE-1-2419-A RE-1-2419-B S0-1-2499-1A S0-1-2499-18 S0-1-2499-2A S0-1-2499-28
GENERIC NAME
PRESSURE TRANSMITTER PRESSURE TRANSMITTER RADIATION DETECTOR RADIATION DETECTOR RADIATION DETECTOR RADIATION DETECTOR SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE
PAGE 017. I QUAD CITIES
\
PAGE 001.
COHHONWEALTH EDISON COMPANY
QUAD CITIES UNIT 2
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 2
DATE OF ISSUE 05-18-1983
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 002.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 2
SYSTEM : REACTOR PROTECTION
PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------TE-2-1291-60A TE-2-1291-608 TE-2-1291-60C TE-2-1291-60D TE-2-1291-60E TE-2-1291-60F TE-2-1291-:60G TE-2-1291-60H
0
TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT
COMMONIJEALTM EDISON COMPANY 05-18-1983 PAGE 003.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 2
SYSTEM : CORE SPRAY
PLANT IDENTIFICATION NUMBER
FS-2-1464A FS-2-1464B FT.,-2-1461A FT-2-1461B M0-2-1402-24A M0-2-1402-24B M0-2-1402-25A M0-2-1402-25B M0-2-1402-3BA M0-2-1402-3BB M0-2-1402-4A M0-2-1402-4B PT-2-1460A PT-2-J..:160B 2-14oi'A 2-1401B
GENERIC NAME
FLOW SWITCH FLOW SWITCH FLOW TRANSMITTER FLOW TRANSMITTER MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GLOBE VALVE MOTOR OPERATED GLOBE VALVE PRESSURE TRANSMITTER PRESSURE TRANSMITTER PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 004.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 2
SYSTEM : HIGH PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUMBER GENERIC NAME
DPIS-2-2352 DIFFERENTIAL PRESSURE INDICATING SWITCH DPIS-2-2353 DIFFERENTIAL PRESSURE INDICATING SWITCH LS-2-2351A LEVEL SWITCH LS-2-2351B LEVEL SWITCH M0-2-2301-35 MOTOR-OPERATED GATE VALVE MD-2-2301-36 MOTOR-OPERATED GATE VALVE M0-2-2301-4 MOTOR-OPERATED GATE VALVE M0-2-2301-5 MOTOR-OPERATED GATE VALVE M0-2-2301-8 MOTOR OPERATED GATE VALVE PS-2-2389A PRESSURE SWITCH (LOlJ) PS-2-2389B PRESSURE SWITCH <LOlJl PS-2-2389C PRESSURE SWITCH <LOW> PS-2-2389D PRESSURE SWITCH <LOW> TS-2-2370A TEMPERATURE SWITCH TS-2-2370B TEMPERATURE SWITCH TS-2-2370C TEMPERATURE SWITCH TS-2-2370D TEMPERATURE SWITCH TS-2-2371A TEMPERATURE SWITCH TS-2-2371B TEMPERATURE SWITCH TS-2-2371C TEMPERATURE SWITCH TS-2-2371D TEMPERATURE SWITCH TS-2-2372A TEMPERATURE SWITCH TS-2-2372B TEMPERATURE SWITCH e TS-2-2372C TEMPERATURE SWITCH TS-2-2372D TEMPERATURE SWITCH TS-2-2373A TEMPERATURE SWITCH TS-2-2373B TEMPERATURE SWITCH TS-2-2373C TEMPERATURE SWITCH TS-2-2373D TEMPERATURE SWITCH
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 005.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 2
SYSTEM : AUTO DEPRESSURIZATION/ HAIN STEAH
PLANT IDENTIFICATION NUMBER
2-203-3B 2-203-3C 2-203-3D 2-203-3E 2-261-60A 2-261-60B 2-261-60C 2-261-60D 2-261-60E 2-262-61A 2-262-61B 2-262-61C 2-262-61D 2-26~61E
GENERIC NAME
ELECTROMATIC RELIEF VALVE AND SOLENOID ELECTROMATIC RELIEF VALVE AND SOLENOID ELECTROMATIC RELIEF VALVE AND SOLENOID ELECTROMATIC RELIEF VALVE AND SOLENOID SENSOR- ACOUSTIC MONITOR SENSOR- ACOUSTIC MONITOR SENSOR- ACOUSTIC MONITOR SENSOR- ACOUSTIC MONITOR SENSOR- ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR
e
COHHONWEALTH EDISON COHPANY 05-19-1993 PAGE 006.
LIST OF EQUIPHENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 2
SYSTEH : RESIDUAL HEAT REHOVAL
PLANT IDENTIFICATION NUMBER GENERIC NAHE
DPIS-2-1001-91A DIFFERENTIAL PRESSURE INDICATING SWITCH DPIS-2-1001-91B DIFFERENTIAL PRESSURE INDICATING SWITCH DPS-2-1001-79A DIFFERENTIAL PRESSURE SWITCH DPS-2-1001-78B DIFFERENTIAL PRESSURE SWITCH FT-2-1042A FLOW TRANSMITTER FT-2-1042B FLOW TRANSHITTER FT-2-1049A FLOW TRANSHITTER FT-2-1049B FLOW TRANSMITTER FT-2-1051A FLOW TRANSHITTER FT-2-1051B FLOW TRANSMITfER LS-2-4941-2A LEVEL SWITCH <HIGH> LS-2-4941-2B LEVEL SWITCH <HIGH> LS-2-41'41-2C LEVEL SWITCH <HIGH> H0-2-1001-16A HOTOR-OPERATED GLOBE VAL~E H0-2-1001-16B ---MOTOR-OPERATED GLOBE VALVE M0-2-1001-19A MOTOR-OPERATED GATE VALVE M0-2-1001-19B HOTOR-OPERATED GATE VALVE H0-2-1001-185A MOTOR OPERATED GATE VALVE M0-2-1001-185B HOTOR OPERATED GATE VALVE H0-2-1001-19A MOTOR-OPERATED GATE VALVE M0-2-1001-19B MOTOR-OPERATED GATE VALVE M0-2-1001-21 MOTOR-OPERATED GATE VALVE M0-2-1001-23A MOTOR-OPERATED GATE VALVE M0-2-1001-23B MOTOR-OPERATED GATE VALVE M0-2-1001-26A MOTOR-OPERATED GATE VALVE M0-2-1001-26B MOTOR-OPERATED GATE VALVE H0-2-1001-29A MOTOR-OPERATED GLOBE VALVE M0-2-1001-28B MOTOR-OPERATED GLOBE VALVE H0-2-1001-29A MOTOR-OPERATED GATE VALVE H0-2-1001-29B MOTOR-OPERATED GATE VALVE H0-2-1001-34A HOTOR-OPERATED GATE VALVE H0-2-1001-34B l~OTOR-OPERATED GATE VALVE M0-2-1001-36A MOTOR-OPERATED GLOBE VALVE M0-2-1001-36B HOTOR-OPERATED GLOBE VALVE M0-2-1001-37A MOTOR-OPERATED GLOBE VALVE M0-2-1001-37B MOTOR-OPERATED GLOBE VALVE M0-2-1001-4A HOTOR OPERATED GATE VALVE M0-2-1001-4B MOTOR OPERATED GATE VALVE H0-2-1001-47 HOTOR-OPERATED GATE VALVE M0-2-1001-SA MOTOR-OPERATED GLOBE VALVE M0-2-1001-SB HOTOR-OPERATED GLOBE VALVE H0-2-1001-50 MOTOR-OPERATED -GATE VALVE H0-2-1001-60 HOTOR-OPERATED GATE VALVE H0-2-1001-63 HOTOR-OPERATED GATE-VALVE M0-2-1001-7A MOTOR-OPERATED GATE VALVE M0-2-1001-7B MOTOR-OPERATED GATE VALVE , M0-2-1001-7C MOTOR-OPERATED GATE VALVE M0-2-1001-7D HOTOR-OPERATED GATE VALVE PT-2-1043A PRESSURE TRANSHITTER PT-2-1043B PRESSURE TRANSHITTER PT-2-1044A PRESSURE TRANSHITTER PT-2-1044B · PRESSURE TRANSMITTER
COHHONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR
SYSTEH : RESIDUAL HEAT REHOVAL
PLANT IDENTIFICATION NUMBER
2-1001-65A 2·-1001-65B 2-1001-65C 2-1001-65D 2-1002A 2-1002Et 2-1002C 2-10020
GENERIC NAME
RHR SERVICE WATER PUHP MOTOR-DRIVEN RHR SERVICE WATER PUHP HOTOR-DRIVEN l~HR SERVICE WATER PUHP HOTOR-DRIVEN RHR SERVICE WATER PUHP HOTOR-DRIVEN PUHP-HOTOR DRIVEN PUMP-HOTOR DRIVEN PUMP-HOTOR DRIVEN PUHP-HOTOR DRIVEN
PAGE 007'.
QUAD CITIES 2
COHHONWEALTH EDISON COHPANY 05-18-1983 PAGE 00~.
LIST OF EQUIPHENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 2
SYSTEH : PRESSURE SUPPRESSION
PLANT IDENTIFICATION NUHBER
LT-2-1641-SA LT-2-1641-SB PS-2-1622A PS-2-1622B PT-2-1641-6A PT-2-1641-6B S0-2-1601-SOA S0-2-1601-SOB TE-2-1630A TE-2-1630B TE-2-1631A TE-2-1631B
GENERIC NAHE
l_EVEL TRANSHITTER LEVEL TRANSHITTER PRESSURE SWITCH PRESSURE SWITCH PRESSURE TRANSMITTER PRESSURE TRANSMITTER SOLENOID VALVE SOLENOID VALVE TEHPERATURE ELEMENT <THERMOCOUPLE) TEHPERATURE ELEMENT <THERHOCOUPLE) TEHPERATURE ELEMENT <THERMOCOUPLE> TEMPERATURE ELEMENT <THERMOCOUPLE)
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 009;
LIST OF EQUIPHENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 2
SYSTEM : SERVICE WATER
PLANT IDENTIFICATION NUMBER
2-5746A 2-5746B 2-5748A 2-5748B
GENERIC NAME
ROOM COOLER FAN HOTOR l~OOM COOLER FAN HOTOR ROOM COOLER FAN HOTOR ROOM COOLER FAN MOTOR
COHHONWEALTH EDISON COHPANY 05-18-1983 PAGE olQJ.
LIST OF EQUIPHENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR . QUAD CITIES 2
SYSTEM : CONTAINHENT ISOLATION
PLANT IDENTIFICATION NUHBER
A0-2-203-lA A0-2-203-lB A0-2-203-lC A0-2-203-lD A0-2-203-2A A0-2-203-28 A0-2-203-2C A0-2-203-2D HD-2-1201-2 t11-2-1201-s
GENERIC NAHE
HSIV AND SOLENOID FOR AIR OPERATOR HSIV AND SOLENOID FOR AIR OPERATOR HSIV AND SOLENOID FOR AIR OPERATOR HSIV AND SOLENOID FOR AIR OPERATOR HSIV AND SOLENOID FDR AIR OPERATOR HSIV AND SOLENOID FOR AIR OPERATOR HSIV AND SOLENOID FOR AIR OPERATOR . HSIV AND SOLENOID FOR AIR OPERATOR HOTOR OPERATED GATE VALVE HDTOR OPERATED GATE VALVE HOTOR OPERATED GLOBE VALVE "OTOR OPERATED GLOBE UALVE HOTOR OPERATED VALVE HOTOR OPERATED GATE VALVE llOTOR-DPERllTED GATE UALVE
. H0-2-220-1 H0-2-220-2 H0-2-3702 H0-2-3'°3 HD-2-3706 TS-2-261-lSA TS-2-261-lSB TS-2-261-lSC TS-2-261-lSD TS-2-261-16A TS-2-261-16B TS-2-261-16C TS-2-261-16D TS-2-261-17A TS-2-261-17B TS-2-261-17C TS-2-261-17D TS-2-261-18A TS-2-261-18B TS-2-261-18C TS-2-261-18D 2-203-311
.. --TEHPERATURE SWITCH . . - .. ·-- -TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH SAFETY RELIEF VALVE 11ND SOLENOID
COHHONWEALTH EDISON COHPANY 05-18-1983 PAGE 01U.
LIST OF EQUIPHENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 2
SYSTEM : REACTOR RECIRCULATION
PLANT IDENTIFICATION NUHBER
A0-2-220-44 LIS-2-263-58A LIS-2-263-58B LITS-2-263-73A LITS-2-263-73:8 H0-2-202-5-A M0-2-202-5-B POS-2-220-44 POS-2-220-45 PT-2-647A PT-2-647B PT-2-662
GENERIC NAME
SOLENOID VALVE LEVEL INDICATOR SWITCH LEVEL INDICATOR SWITCH LEVEL INDICATING TRANSHITTER SWITCH LEVEL INDICATING TRANSHITTER SWITCH
MOTOR OPERATED GATE VALVE & BRAKE MOTOR OPERATED GATE VALVE & BRAKE
POSITION SWITCH POSITION SWITCH PRESSURE TRANSHITTER PRESSURE TRANSHITTER PRESSURE TRANSMITTER
/
COMHONWEALTH EDISON COHPANY 05-18-1983 PAGE O~~.
LIST OF EQUIPHENT REQUIRED TD BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FDR QUAD CITIES 2
SYSTEM : PROCESS RADIATION HDNITORING
PLANT IDENTIFICATION NUMBER
RE-2-1735A RE-2-1735B
GENERIC NAME
RADIATION ELEMENT GM TUBE RADIATION ELEMENT GH TUBE
COHHONWEALTH EDISON COHPANY <>5-18-1983 PAGE 013.
LIST OF EQUI~HENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 2
SYSTEH : STANDBY AC POWER
PLANT IDENTIFICATION NUHBER
HCC 28-1A HCC 28-lB HCC 28-3 HCC 28/29-5 HCC 29-1 HCC 29-3 HCC 29-6
GENERIC NAME
-480 V HCC 480 V HCC -480 V HCC -480 V HCC 480 V HCC -480 V HCC -480 V HCC
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 014.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 2
SYSTEM : STANDBY DC POWER
PLANT IDENTIFICATION NUMBER GENERIC NAME
125 V DCDP 1 125 V DC REACTOR BLDG DISTRIBUTION PANEL
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR
SYSTEM : REACTOR CORE ISOLATION COOLING
PLANT IDENTIFICATION NUMBER
M0-2-1301-16 M0-2-1301-17 TS-2-1360-14A TS-2-1360-14B TS-2-1360-14C TS-2-1360-14D TS-2-1360-15A TS-2-1360-15B TS-2-1360-15C TS-2-1360-150 TS-2-1360-16A TS-2-1360-16B TS-2-1360-16C TS-2-1360-160 TS-2~360-17A
TS-2-1360-17B TS-2-1360-17C TS-2-1360-170
GENERIC NAME
MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH
PAGE 015.
QUAD CITIES 2
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 016.
~ LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 2
SYSTEH : GENERAL USE ELECTRICAL EQUIPMENT
PLANT IDENTIFICATION NUHBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE'S CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE <SHIELDED> CABLE <SHIELDED> 2X-100B 2X-100C 2X-100E 2X-100F 2X-100G 2X-101A 2X-101B 2X-101D 2X-102B 2X-103 2X-104A 2X-104B 2X-104C: 2X-104D 2X-104F 2X-105C 2X-106A 2X-106B 2X-107A 2X-107B
GENERIC NAME
ANHYDREX XX PLASTEX INSU & JKT ANHYDREX XX PLASTEX INSU & JKT BUTYL RBR INSU POLYVN CHLORIDE JKT BUTYL RBR INSU POLYVN CHLORIDE JKT BUTYL RBR INSU POLYVN CHLORIDE JKT CROSSLINKED POLYFIN W-16 AWG DRN & JKT ~SPE INSUL., POLYESTER ALUMINUH SHLD. AND CSPE JKT. EPDM I INSUL. W/HAPALON COND. JKT AND OVERALL H I JKT EPDM I INSUL. W/HAPALON COND. JKT AND OVERALL H I JKT EPDH II INSUL. W/HAPALON COND. JKT. AND OVERALL H II JKT. EPDM INSUL. W/HAPALON JKT DRN. AND SHLD. W/OVERALL EPR INSUL. CSPE JKT. EPR W/CSPE JKT., FR SHLD, DRN WIRE AND OVERALL CSPE JKT. EPR W/CSPE JKT., FR SHLD, DRN WIRE AND OVERALL CSPE JKT. EPR W/NEOPRENE INSUL. AND JKT. FR-EPDM AND 16 AWG AND HYPALON JKT. HULT! PAIR WITH OVERALL SH CO-CON OKONITE EPR INSUL. WITH OKO COVER AND OVERALL OKO JKT POLY NYLON INSU SHLD & PLASTEX INSTR POLYETH INSU POLYV CHLORIDE JKT RBR INSU POLYV CHLORIDE JACKET SINGLE/HULTIPAIR CABLE WITH OVERALL SH SR INSUL. WITH GLASSBRAID AND SIL. SAT. ASBESTOS BRAIDED SWITCHBOARD-TYPE SIS tSI 57275 VULKENE XLPE INSUL. WITH NEOPRENE JKT. 3 TW WITH OVERALL SH EPR INSUL. COPPER DRN WIRES CHLORINATED POLYETHYLENE JKT EPR INSUL. EXTRUDED SEHI COND. CSPE INSUL. SHIELD, CSPE J ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 017.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR QUAD CITIES 2
SYSTEM : CAM
PLANT IDENTIFICATION NUMBEF: GENERIC NAME ---------------------------------------------------------------------------------------------------HS-2-2402-C HS-2-2402-D PT-2-2421-A PT-2-2421-B RE-2-2418-A RE-2-2418-B RE-2-2418-C RE-2-2418-D RE-2-2419-A RE-2-2419-B
HYDROGEN SENSOR HYDROGEN SENSOR PRESSURE TRANSMITTER PRESSURE TRANSMITTER RADIATION DETECTOR RADIATION DETECTOR RADIATION DETECTOR RADIATION DETECTOR l~ADIATION DETECTOR RADIATION DETECTOR
PAGE 001.
COMMONWEALTH EDISON COMPANY
DRESDEN UNIT 2
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 2
DATI:: OF ISSUE 05-18-1983
.e COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 002.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 2
SYSTEM : REACTOR PROTECTION
PLANT IDENTIFICATION NUMBER
TE-2-1291-60A TE-2-1291-60B TE-2-1291-60C TE-2-1291-60D TE-2-1291-60E TE-2-1291-60F TE-2-1291-60G TE-2-1291-60H
GENERIC NAME
TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT
COMMONWEALTH EDISON COMPANY 05-18-1983
~ST OF EQUIPHENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR
SYSTEM : CORE SPRAY
PLANT IDENTIFICATION NUMBER
FS-2-1464A FS-2-14648 FT-2-1461A FT-2-14618 M0-2-1402-24A H0-2-1402-24B M0-2-1402-25A H0-2-1402-258 H0-2-1402-38A M0-2-1402-388 PT-2-1460A PT-2-1460B 2-140H1 2-1401B
GENERIC NAHE
FLOW SWITCH FLOW SWITCH FLOW TRANSMITTER FLOW TRANSMITTER HOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE HOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE PRESSURE TRANSMITTER PRESSURE TRANSMITTER PUHP-MOTOR DRIVEN PUMP-MOTOR DRIVEN
PAGE 003.
DRESDEN 2
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 004.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 2
SYSTEM : HIGH PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUMBER
DPIS-2-2352 DPIS-2-2353 LS-2-2351A LS-2-2351B M0-2-2301-35 M0-2-2301-4 M0-2-2301-5 M0-2-2301-8 PS-2-2389A PS-2-2389B PS-2-2389C PS-2-2389D TS-2-2370A TS-2-2370B TS-2-2370C TS-2-2370D TS-2-2371A TS-2-2371B TS-2-2371C TS-2-2371D TS-2-2372A TS-2-2372B TS-2-2372C TS-2-2372D
A-2-2373A ·-2-2373B
TS-2-2373C TS-2·-2373D
GENERIC NAME
DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH LEVEL SWITCH LEVEL SWITCH MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE PRESSURE SWITCH PRESSURE SWITCH PRESSURE SWITCH PRESSURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 005.
LIST OF EQUIPHENT REQUIRED TO BE QUALtFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 2
SYSTEM : AUTO DEPRESSURIZATION/ HAIN STEAH
PLANT IDENTIFICATION NUMBER
TS-2-261-15A TS-2-261-15£! TS-2-261-15C TS-2-261-15D TS-2-261-16A TS-2-261-16B TS-2-261-16C TS-2-261-16D TS-2-261-17A TS-2-261-17£1 TS-2-261-17C TS-2-261-17D TS-2-261-18A TS-2-261-18B TS-2-261-18C TS-2-261-18D 2-203-3A 2-203-3B 2-203-3C 2-203-3D 2-203-3E 2-261-60A 2·-261-60B
-61-60C ~1-60D 2·-261-60E 2-262-61A 2-262-61B 2·-262-61C 2-262-61D 2·-262-61E
GENERIC NAME
TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEHPERATURE SWITCH TEHPERATURE SWITCH TEMPERATURE SWITCH SAFETY RELIEF VALVE AND SOLENOID ELECTROHATIC RELIEF VALVE AND SOLENOID ELECTROMATIC RELIEF VALVE AND SOLENOID ELECTROMATIC RELIEF VALVE AND SOLENOID ELECTROMATIC RELIEF VALVE AND SOLENOID SENSOR- ACOUSTIC MONITOR SENSOR- ACOUSTIC HONITOR SENSOR- ACOUSTIC HONITOR SENSOR- ACOUSTIC HONITOR SENSOR- ACOUSTIC HONITOR PREAMPLIFIER ACOUSTIC MONITOR PREAHPLIFIER ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC HONITOR PREAHPLIFIER ACOUSTIC HONITOR PREAHPLIFIER ACOUSTIC MONITOR
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 006.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 2
SYSTEM : LOW PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUMBER
DPS-2-1501-55A DPS-2-1501-558 DPT-2-1543A DPT-2-15438 FS-2-1501-58A FS-2-1501-58B FT-2-1542A FT-2-15428 FT-2-1549A FT-2-1549B FT-2-1551A FT-2-1551B M0-2-1501-UA M0-2-1501-118 M0-2-1501-21A M0-2-1501-21B M0-2-1501-27A M0-2-1501-278 M0-2-1501-28A M0-2-1501-28B M0-2-1501-3A M0-2-1501-38 M0-2-1501-32A
~2-1501-32B
WJ502A 2-15028 2-1502C 2-1502D
GENERIC NAME
DIFFERENTIAL PRESSURE SWITCH DIFFERENTIAL PRESSURE SWITCH DIFFERENTIAL PRESSURE TRANSMITTER DIFFERENTIAL PRESSURE TRANSMITTER FLOW SWITCH FLOW SWITCH FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED STOP CHECK VALVE MOTOR OPERATED STOP CHECK VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GLOBE VALVE MOTOR OPERATED GLOBE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 007.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 2
SYSTEM : PRESSURE SUPPRESSION
PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------DPIS-2-1622A DPIS-2-1622B LT-2-1641-1 LT-2-1641-5A LT-2-1641-5B PT-2-1625 PT-2-1641-6A PT-2-1641-6B S0-2-1601-50A S0-2-1601-50B S0-2-9203A S0-2-9203B S0-2-9204A S0-2-9204B
DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH LEVEL TRANSMITTER LEVEL TRANSMITTER LEVEL TRANSMITTER PRESSURE TRANSMITTER PRESSURE TRANSMITTER PRESSURE TRANSMITTER SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 008.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 2
SYSTEM : STANDBY GAS TREATMENT
PLANT IDENTIFICATION NUMBER GENERIC NAME
FSL-2/3-7541-41A FLOW SWITCH LOW FSL-2/3-7541-41B FLOW SWITCH LOW FS-2/3-7541-45A FLOW SWITCH FS-2/3-7541-45B FLOW SWITCH M0-2/3 7505A MOTOR OPERATED DAMPER M0-2/3-7504A MOTOR OPERATED DAMPER M0-2/3-7504B MOTOR OPERATED DAMPER M0-2/3-7505B MOTOR OPERATED DAMPER M0-2/3-7507A MOTOR OPERATED DAMPER M0-2/3-7507B MOTOR OPERATED DAMPER TSH-2/3-7541-11A TEMPERATURE SWITCH HIGH TSH-2/3-7541-llB TEMPERATURE SWITCH HIGH 2223-28A LOCAL PANEL 2223-28B LOCAL PANEL 2223-29A LOCAL PANEL 2223-29B LOCAL PANEL 2/3-7503A ELECTRIC AIR HEATER 2/3-7503B ELECTRIC AIR HEATER 2/3-7506A MOTOR EXHAUST FAN 2/3-7506B MOTOR EXHAUST FAN
/
COMMONWEALTH EDISON COMPANY 05-18-1983
~T OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.~9 FOR
SYSTEM : SERVICE WATER
PLANT IDENTIFICATION NUMBER
2-5746A 2-5746B
GENERIC NAME
REACTOR BLDG EMERGENCY AIR COOLER REACTOR BLDG EMERGENCY AIR COOLER
PAGE 009.
DRESDEN 2
'
COMMONWEALTH EDISON COMPANY 05-18-1983
~T OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 fOR
SYSTEM : CONTAINMENT ISOLATION
PLANT IDENTIFICATION NUMBER
M0-2-1001-lA M0-2-1001-HI M0-2-1201-1 M0-2-1201-2 M0-2-1201-3 M0-2-220-1 M0-2-220-2 i~0-2-3706
S0-2-203-lA S0-2-203-lB S0-2-203-lC S0-2-203-lD '.30-2-203-2A S0-2-203-2B S0-2-203-2C S0-2-203-2D
GENERIC NAME
MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GLOBE VALVE MOTOR OPERATED GLOBE VALVE MOTOR OPERATED GATE VALVE SOLENOID FOR MSIV AIR OPERATOR SOLENOID FOR HSIV AIR OPERATOR SOLENOID FOR HSIV AIR OP~RATOR SOLENOID FOR MSIV AIR OPERATOR SOLENOID FOR MSIV AIR OPERATOR SOLENOID FOR HSIV AIR OPERATOR SOLENOID FOR HSIV AIR OPERATOR SOLENOID FOR HSIV AIR OPERATOR
PAGE 010.
DRESDEN 2
COHHONWEALTH EDISON COMPANY 05-18-1983 PAGE 011.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 2
SYSTEM : REACTOR RECIRCULATION
PLANT IDENTIFICATION NUMBER
LIS-2-263-58A LIS-2-263-58B LITS-2-263-73A L ITS-2-263-738 M0-2-202-5A M0-2-202-58 M0-2-202-7A M0-2-202-78 M0-2-205-2-4 POS-2-220-44 POS-2-220-45 l"OS-2-220-51 l"OS-2-220-52 S0-2-220-44
GENERIC NAME
LEVEL INDICATING SWITCH LEVEL INDICATING SWITCH LEVEL INDICATING TRANSMITTING SWITCH LEVEL INDICATING TRANSMITTING SWITCH MOTOR OPERATED GATE VALVE & BRAKE MOTOR OPERATED GATE VALVE & BRAKE HOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE POSITION SWITCH POSITION SWITCH POSITION SWITCH POSITION SWITCH SOLENOID VALVE
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 012.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 2
SYSTEM : STANDBY AC POWER
PLANT IDENTIFICATION NUMBER
HCC 28-1 MCC 28-7 MCC 29-1 MCC 29-3 MCC 29-4 MCC 29-7 SWGR 23-1 SWGR 24-1
GENERIC NAME
480 V HCC 480 V HCC 480 V HCC 480 V HCC 480 V MCC 480 V HCC 4.16 KV SWITCHGEAR 4.16 KV SWITCHGEAR
/
~ COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN
SYSTEM : ISOLATION CONDENSER
PLANT IDENTIFICATION NUMBER
M0-2-1301-1 H0-2-1301-2 M0-2-1301-3 M0-2-1301-4
GENERIC NAME
MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE
PAGE 013.
2
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 014.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 2
SYSTEM : GENERAL USE ELECTRICAL EQUIPMENT
PLANT IDENTIFICATION NUMBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
.. LE LE LE
CABLE <SHIELDED> 2X-200A 2X-200B 2X-202B 2X-202BB 2X-202D 2X-202F 2X-202J 2X-202N 2X-202Q 2X-202S 2X-202W 2X-203A 2X-203B 2X-204E 2X-204H 2X-204P 2X-204Q 2X-204S 2X-204T 2X-205E 79-0lB-14 79-0lB-15 79-01IH6 79-0lB-17 79-01B-18 79-01B-19 79-01B-20 79-01B-21
GENERIC NAME
ANHYDREX XX PLASTEX INSU & JKT ANHYDREX XX PLASTEX INSU & JKT BUTYL RBR INSU POLYVN CHLORIDE JKT BUTYL RBR INSU POLYVN CHLORIDE JKT BUTYL RBR INSU POLYVN CHLORIDE JKT CROSSLINKED POLYFIN W-16 AWG DRN & JKT CSPE INSUL., POLYESTER ALUMINUM SHLD. AND CSPE JKT. EPDM I INSUL. W/HAPALON COND. JKT AND OVERALL H I JKT EPDM I INSUL. W/HAPALON COND. JKT AND OVERALL H I JKT EPDM II INSUL. W/HAPALON COND. JKT. AND OVERALL H II JKT. EPDM INSUL. W/HAPALON JKT DRN. AND SHLD. W/OVERALL EPR INSUL. COPPER DRAIN WIRES CHLORINATED POLYETHYLENE JK EPR INSUL. CSPE JKT. EPR W/CSPE JKT., FR SHLD, DRN WIRE AND OVERALL CSPE JKT. EPR W/CSPE JKT .-, FR SHLD, DRN WIRE AND OVERALL CSPE JKT. EPR W/NEOPRENE INSUL. AND JKT. FR-EPDM AND 16 AWG AND HYPALON JKT. MULTI PAIR WITH OVERALL SH CU-CON OKONITE EPR INSUL. WITH OKO COVER AND OVERALL OKO JKT POLY NYLON INSU SHLD & PLASTEX INSTR POLYETH INSU POLYV CHLORIDE JKT RBR INSU POLYV CHLORIDE JACKET SINGLE/MULTIPAIR CABLE WITH OVERALL SH SR INSUL. WITH GLASSBRAID AND SIL. SAT. ASBESTOS BRAIDED SWITCHBOARD-TYPE SIS tSI 57275 VULKENE XLPE INSUL. WITH NEOPRENE JKT. 3 TW WITH OVERALL SH EPR INSUL. EXTRUDED SEMI. COND. CSPE INSUL. SHLD, CSPE JK ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK
COHHONWEALTH EDISON COMPANY 05-18-1983 PAGE 015.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 2
SYSTEM : CAM
PLANT IDENTIFICATION NUHBER GENERIC NAME ---------------------------------------------------------------------------------------------------HS-2-2402-A HS-2-2402-B HS-2-2402-C HS-2-2402-D PT-2-2421-A PT-2-2421-B RE-2-2418-A RE-2-2418-B RE-2419-A RE-2419-B S0-2-2499-lA S0-2-2499-lB S0-2-2499·-2A S0-2-2499-2B S0-2-2499-3A S0-2-2499-3B S0-2-2499-4A S0-2-2499-4B
HYDROGEN SENSOR HYDROGEN SENSOR HYDROGEN SENSOR HYDROGEN SENSOR PRESSURE TRANSMITTER PRESSURE TRANSMITTER RADIATION DETECTOR RADIATION DETECTOR RADIATION DETECTOR RADIATION DETECTOR SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE
PAGE 001.
COHHONWEALTH EDISON COHPANY
DRESDEN UNIT 3
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 3
DATE OF ISSUE 05-18-1983
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 002.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 3
SYSTEM : REACTOR PROTECTION
PLANT IDENTIFICATION NUMBER
TE-3-1291-60A TE-3-1291-60B TE-3-1291-60C TE-3-1291-60D TE-3-1291-60E TE-3-1291-60F TE-3-1291-60G TE-3-1291-60H
GENERIC NAME
TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT TEMPERATURE ELEMENT
COMMONWEALTH EDISON COMPANY 05-18-1983
~ST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR
SYSTEM : CORE SPRAY
PLANT IDENTIFICATION NUMBER
FS-3-1464A FS-3-1464B FT-3-1461A FT-3-1461B M0-3-1402-24A M0-3-1402-24B M0-3-1402-25A M0-3-1402-25B M0-3-1402-38A M0-3-1402-388 PT-3-1460A PT-3-1460B 3-1401A 3-1401B
GENERIC NAME
FLOIJ SWITCH FLOW SWITCH FLOW TRANSMITTER FLOW TRANSMITTER MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE PRESSURE TRANSMITTER PRESSURE TRANSMITTER PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN
PAGE 003.
DRESDEN 3
' I
COMMONWEALTH EDISON COMPANY 05-18-1983
~ST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR
SYSTEM : HIGH PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUMBER
DPIS-3-2352 DPIS-3-2353 LS-3-2351A LS-3-2351B M0-3-2301-35 M0-3-2301-36 M0-3-2301-4 M0-3-2301-5 M0-3-2301-B PS-3-2389A PS-3-2389B PS-3-2389C PS-3-2389D TS-3-2370A TS-3-2370B TS-3-2370C TS-3-2370D TS-3-2371A TS-3-2371B TS-3-2371C TS-3-2371D TS-3-2372A TS-3-2372B TS-3-2372C TS-3-2372D
--3-2373A --3-2373B
TS-3-2373C TS-3-2373D
GENERIC NAME
DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH LEVEL SWITCH LEVEL SWITCH MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE PRESSURE SWITCH PRESSURE SWITCH PRESSURE SWITCH PRESSURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWiTCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH
PAGE 004.
DRESDEN 3
COMMONWEALTH EDISON COMPANY 05-18-1983
-ST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR
SYSTEM : AUTO DEPRESSURIZATION/ MAIN STEAM
PLANT IDENTIFICATION NUMBER
TS-3-261-15A TS-3-261-15B TS-3-261-15C TS-3-261-1'5D TS-3-261-16A TS-3-261-168 TS-3-261-16C TS-3-261-16D TS-3-261-17A TS-3-261-17B TS-3-261-17C TS-3-261-17D TS-3-261-18A TS-3-261-18B TS-3-261-18C TS-3-261-18D 3-203-3A 3-203-3B 3-203-3C 3-203-3D :3--203-3E 3-261-60A 3-261-60B 3-261-60C 3-261-60D
Ai261-60E -262-61A
3-262-61B 3-262-61C 3-262-61D 3-262-61E
GENERIC NAME
TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH BAFETY RELIEF VALVE AND SOLENOID ELECTROMATIC RELIEF VALVE AND SOLENOID ELECTROMATIC RELIEF VALVE AND SOLENOID ELECTROMATIC RELIEF VALVE AND SOLENOID ELECTROMATIC RELIEF VALVE AND SOLENOID BENSOR-ACOUSTIC MONITOR SENSOR-ACOUSTIC MONITOR SENSOR-ACOUSTIC MONITOR SENSOR-ACOUSTIC MONITOR SENSOR-ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR PREAMPLIFIER ACOUSTIC MONITOR
PAGE 00'5.
DRESDEN 3
COHHONWEALTH EDISON COHPANY 05-18-1983
~ST OF EQUIPHENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR
SYSTEM : LOW PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUHBER
DPS-3-1501-55A DPS-3-1501-55B DPT-3-1543A DPT-3-1543B FS-3-1501-58A FS-3-1501-58B FT-3-1542A FT-3-1542B FT-3-1549A FT-3-1549B FT-3-1551A FT-3-1551B i'I0-3-1501-llA H0-3-1501-llB M0-3-1501-21A M0-3-1501-21B H0-3-1501-27A M0-3-1501-27B H0-3-1501-28A H0-3-1501-288 M0-3-1501-3A M0-3-1501-3B M0-3-1501-32A M0-3-1501-32B 3-1502A
A.1502B •1502c
3-1502D
GENERIC MAHE
DIFFERENTIAL PRESSURE SWITCH DIFFERENTIAL PRESSURE SWITCH DIFFERENTIAL PRESSURE TRANSMITTER DIFFERENTIAL PRESSURE TRANSMITTER FLOW SWITCH FLOW SWITCH FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED-STOP CHECK VALVE MOTOR OPERATED STOP CHECK VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GLOBE VALVE & BRAKE MOTOR OPERATED GLOBE VALVE & BRAKE MOTOR OPERATED GATE VALVE: MOTOR OPERATED GATE VALVE PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN -PUMP-MOTOR DRIVEN
PAGE 006.
DRESDEN 3
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 007.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 3
SYSTEM : PRESSURE SUPPRESSION
PLANT IDENTIFICATION NUMBER
DPIS-3"-1622A DPIS-3-1622B LT-3-1626 · LT-3-1641-1 LT-3-1641-5A LT-3-1641-5B PT-3-1641-6A PT-3-1641-6B S0-3-1601-50A S0-3-1601-50B S0-3-9203A S0-3-92038 S0-3-9204A S0-3-92048
GENERIC NAME
DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH LEVEL TRANSMITTER LEVEL TRANSMITTER LEVEL TRANSMITTER LEVEL TRANSMITTER PRESSURE TRANSMITTER PRESSURE TRANSMITTER SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE
~ COMMONWEALTH EDISON COMPANY 05-18-1983
~ST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN
SYSTEM : SERVICE WATER
PLANT IDENTIFICATION NUMBER
3·-5746A 3-5746B
GENERIC NAME
REACTOR BLDG EMERGENCY AIR COOLER REACTOR BLDG EMERGENCY AIR COOLER
PAGE 008.
3
COHHONWEALTH EDISON COMPANY 05-18-1983
~IST ·OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR
SYSTEM : CONTAINMENT ISOLATION
PLANT IDENTIFICATION NUMBER
M0-3-1001-lA M0-3-1001-lB M0-3-1201-1 M0-3-1201-2 M0-3-1201-3. M0-3-220-1
.M0-3-220-2 M0-3-3702 H0-3-3706 S0-3-203-lA S0-3-203-lB S0-3-203-lC S0-3-203-lD S0-3-203-2A S0-3-203-2B S0-3-203-2C S0-3-203-2D
GENERIC NAME
HOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GLOBE VALVE MOTOR OPERATED GLOBE VALVE MOTOR OPERATED VALVE MOTOR OPERATED GATE VALVE SOLENOID FOR MSIV AIR OPERATOR SOLENOID FOR MSIV AIR OPERATOR SOLENOID FOR HSIV AIR OPERATOR SOLENOID FOR HSIV AIR OPERATOR SOLENOID FOR MSIV AIR OPERATOR SOLENOID FOR HSIV AIR OPERATOR SOLENOID FOR HSIV AIR OPERATOR SOLENOID FOR HSIV AIR OPERATOR
PAGE 009.
DRESDEN 3
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 010.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 3 .
SYSTEM : REACTOR RECIRCULATION
PLANT IDENTIFICATION NUMBER
DPIS-3-261-35A DPIS-3-261-35B DPIS-3-261-35C DPIS-3-261-35D DPIS-3-261-35E DPIS-3-261-35F DPIS-3-261-35G DPIS-3-261-35H LIS-3-263-58A LIS-3-263-58B LITS-3-263-73A LITS-3-263-73B M0-3-202-5A H0-3-202-5B M0-3-202-7A M0-3-202-7B M0-3-205-2-4 POS-3-220-44 POS-3-220-45 POS-3-220-51 POS-3-220-52 S0-3-220-44
GENERIC NAME
DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH LEVEL INDICATING SWITCH LEVEL INDICATING SWITCH LEVEL INDICATING TRANSMITTING SWITCH LEVEL INDICATING TRANSMITTING SWITCH MOTOR OPERATED GATE VALVE & BRAKE MOTOR OPERATED GATE VALVE & BRAKE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE POSITION SIJITCH POSITION SWITCH POSITION SWITCH POSITION SWITCH SOLENOID VALVE
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 011.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 3
SYSTEM : STANDBY AC POWER
PLANT IDENTIFICATION NUMBER
HCC 38-1 HCC 38-2 HCC 38-3 HCC 38-4 HCC 38-7 HCC 39-1 MCC 39-2 HCC 39-3 HCC 39-7 SWGR 33-1 SWGR 34-1
GENERIC NAME
480 V HCC 480 V HCC 480 V HCC 480 V HCC 480 V HCC 480 V HCC 480 V HCC 480 V HCC 480 V HCC 4.16 KV SWITCHGEAR 4.16 KV SWITCHGEAR
COHMONWEALTH EDISON COMPANY 05-18-1983 PAGE 012.
LIST OF EQUIPHENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 3
SYSTEH : ISOLATION CONDENSER
PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------H0-3-1301-1 M0-3-1301-2 M0-3-1301-3 M0-3-1301-4
MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE
COHHONWEALTH EDISON COHPANY 05-18-1983 PAGE 013.
_.IST OF EQUIPHENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR
SYSTEM : GENERAL USE ELECTRICAL EQUIPHENT
DRESDEN
PLANT IDENTIFICATION NUHBER
CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE
~ABLE (SHIELDED> ~ABLE <SHIELDED>
3X-200C 3X-201B 3X-202B 3X-202BB 3X-202D 3X-202F 3X-202J 3X-202N 3X-202S 3X-2021J 3X-203El 3X-204A 3X-204E 3X-204H 3X-204L 3X-204H 3X-204N 3X-204Q 3X-204S 3X-205B 79-01B-14 79-0lB-15 79-0lB-16 79-0lB-17 79-0lB-18 79-0lB-19 79-01B-20 79-01B-21
GENERIC NAHE
ANHYDREX XX PLASTEX INSU & JKT ANHYDREX XX PLASTEX INSU & JKT BUTYL RBR INSU POLYVN CHLORIDE JKT BUTYL l~BR INSU POL YVN CHLORIDE JKT BUTYL RBR INSU POLYVN CHLORIDE JKT CROSSLINKED POLYFIN IJ-16 Al.JG DRN & JKT
. CSPE INSUL., POLYESTER ALUHINUH SHLD. AND CSPE JKT. EPDH I INSUL. W/HAPALON COND. JKT AND OVERALL H I JKT EPDH I INSUL. W/HAPALON COND. JKT AND OVERALL H I JKT EPDH II INSUL. W/HAPALON COND. JKT. AND OVERALL H II JKT. EPDH INSUL. W/HAPALON JKT DRN. AND SHLD. W/OVERALL EPR INSUL. CSPE JKT. EPR W/CSPE JKT., FR SHLD, DRN WIRE AND OVERALL CSPE JKT. EPR W/CSPE JKT., FR SHLD, DRN WIRE AND OVERALL CSPE JKT. EPR W/NEOPRENE INSUL. AND JKT. FR-EPDM AND 16 Al.JG AND HYPALON JKT. MULTI PAIR IJITH OVERALL SH CU CON OKONITE EPR INSUL. WITH OKO COVER AND OVERALL OKO JKT POLY NYLON INSU SHLD & PLASTEX INSTR POLYETH INSU POLYV CHLORIDE JKT RBR INSU POLYV CHLORIDE JACKET SINGLE/MULTIPAIR CABLE WITH OVERALL SH SR INSUL. WITH GLASSBRAID AND SIL. SAT. ASBESTOS BRAIDED SWITCHBOARD-TYPE SIS tSI 57275 VULKENE XLPE INSUL. WITH NEOPRENE JKT. 3 TW WITH OVERALL SH EPR INSUL. COPPER DRN WIRES CHLORINATED POLYETHYLENE JKT EPR INSUL. EXTRUDED SEHI COND. CSPE INSUL. SHIELD, CSPE J ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION TERHINAL BLOCK TERMINAL BLOCK TERHINAL BLOCK TERHINAL BLOCK TERHINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK TERMINAL BLOCK
3
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 014.
LIST OF EQUIPMENT REQUIRED TO BE QUALIFIED PURSUANT TO 10 CFR PART 50.49 FOR DRESDEN 3
~YSTEM : CAM ~ --------------------------------------------------
PLANT IDENTIFICATION NUMBER
HS-3-2402-A HS-3-2402-B HS-3-2402-C HS-3-2402-D PT-3-2421-A PT-3-2421-B . RE-3-2419-A RE-3-2419-B S0-3-2499-lA S0-3-2499-1B S0-3-2499-2A S0-3-2499-2B S0-3-2499-3A S0-3-2499-3B S0-3-2499-4A S0-3-2499-48
GENERIC NAME
HYDROGEN SENSOR HYDROGEN SENSOR HYDROGEN SENSOR HYDROGEN SENSOR PRESSURE TRANSMITTER PRESSURE TRANSMITTER RADIATION DETECTOR RADIATION DE1ECTOR SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE
·'I
PAGE 001.
COi'IMONWEALTH EDISON COMPANY
QUAD CITIES UNIT 1
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 1
DATE OF ISSUE 05-18-1983
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 1
SYSTEM : CORE SPRAY
PLANT IDENTIFICATION NUMBER
FT-1-1461A FT-1-1461B M0-1-1402-'IA M0-1-1402-4B PT-1-1460A PT-1-1460B 1-1401A 1-1401B
GENERIC NAME
FLOW TRANSMITTER FLOW TRANSMITTER MOTOR OPERATED GLOBE VALVE MOTOR OPERATED GLOBE VALVE PRESSURE TRANSMITTER PRESSURE TRANSMITTER PUMP-MOTOR DRIVEN PUMP-MOTOI~ DRIVEN
PAGE 002.
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 003.
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES
SYSTEM : HIGH PRESSURE COOLANT INJECTION ---~--------------------------------------------
PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------LS-1-2351A LS-1-2351B M0-1-2301-35 M0-1-2301-36
LEVEL SWITCH LEVEL SWITCH MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 004.
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 1
SYSTEM : AUTO DEPRESSURIZATION/ HAIN STEAM
PLANT IDENTIFICATION NUMBER GENERIC NAME
1-203-3A SAFETY RELIEF VALVE AND SOLENOID
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 005.
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES
SYSTEM : RESIDUAL HEAT REMOVAL
PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------FT-1-1042A FLOW TRANSMITTER FT-1-1042B FLOW TRANSMITTER FT-1-1049A FLOW TRANSMITTER FT-1-1049B FLOW TRANSMITTER FT-1-1051A FLOW TRANSMITTER FT-1-1051B FLOW TRANSMITTER LS-1-4941-2A LEVEL SWITCH <HIGH> LS-1-4941-2B LEVEL SWITCH CHIGH> LS-1-4941-2C LEVEL SWITCH CHIGH> M0-1-1001-16A MOTOR-OPERATED GLOBE VALVE M0-1-1001-16B MOTOR-OPERATED GLOBE VALVE H0-1-1001-18A MOTOR-OPERATED GATE VALVE M0-1-1001-lBB MOTOR-OPERATED GATE VALVE M0-1-1001-185A MOTOR OPERATED GATE VALVE M0-1-1001-185B MOTOR OPERATED GATE VALVE M0-1-1001-19A MOTOR-OPERATED GATE VALVE M0-1-1001-19B MOTOR-OPERATED GATE VALVE M0-1-1001-21 MOTOR-OPERATED GATE VALVE M0-1-1001-36A MOTOR-OPERATED GLOBE VALVE M0-1-1001-36B MOTOR-OPERATED GLOBE VALVE M0-1-1001-37A MOTOR-OPERATED GLOBE VALVE M0-1-1001-37B MOTOR-OPERATED GLOBE VALVE M0-1-1001-'IA MOTOR OPERATED GATE VALVE M0-1-1001-'IB MOTOR OPERATED GATE VALVE M0-1-1001-47 MOTOR-OPERATED GATE VALVE
e M0-1-1001-7A MOTOR-OPERATED GATE VALVE M0-1-1001-7B MOTOR-OPERATED GATE VALVE M0-1-1001-7C MOTOR-OPERATED GATE VALVE M0-1-1001-7D MOTOR-OPERATED GATE VALVE PT-1-1043A PRESSURE TRANSMITTER PT-1-1043B PRESSURE TRANSMITTER PT-1-1044A PRESSURE TRANSMITTER PT-1-1044B PRESSURE TRANSMITTER 1-1001-65A RHR SERVICE WATER PUMP MOTOR-DRIVEN 1-1001-65B RHR SERVICE WATER PUMP MOTOR-DRIVEN 1-1001-65C RHR SERVICE WATER PUMP MOTOR-DRIVEN 1-1001-65D RHR SERVICE WATER PUHP MOTOR-DRIVEN 1-1002A PUMP-MOTOR DRIVEN 1-1002Et PUMP-MOTOR DRIVEN 1-1002C PUMP-MOTOR DRIVEN 1-1002D PUMP-MOTOR DRIVEN 1-5745A ROOM COOLER CFAN MOTOR> 1-5745B ROOM COOLER CFAN MOTOR> 1-5745C ROOM COOLER CFAN MOTOR> 1-5745D ROOM COOLER _CFAN MOTOR)
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 006.
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 1
SYSTEM : PRESSURE SUPPRESSION
PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------LT-1-1641-SA LT-1-1641-SB PT-1-1625 PT-1-1641-6A PT-1-1641-6B
LEVEL TRANSMITTER LEVEL TRANSMITTER PRESSURE TRANSMITTER PRESSURE TRANSMITTER PRESSURE TRANSMITTER
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 1
SYSTEM : CONTAINMENT ISOLATION
PLANT IDENTIFICATION NUMBER
M0-1-1201-5 110-1-220-2 H0-1-3702 H0-1-3703
GENERIC NAME
MOTOR OPERATED GATE VALVE HOTOR OPERATED GLOBE VALVE MOTOR OPERATED VALVE MOTOR OPERATED GATE VALVE
PAGE 007.
COHHONWEALTH EDISON COMPANY
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES
SYSTEM : REACTOR RECIRCULATION
PLANT IDENTIFICATION NUMBER
A0-1-220--44 PT-1-662
GENERIC NAME
SOLENOID VALVE PRESSURE TRANSMITTER
05-18-1983 PAGE 008.
COHHONWEALTH EDISON COHPANY 05-18-1983
LIST OF EQUIPHENT THAT IS ENVIRONHENTALLY QUALIFIED FOR QUAD CITIES 1
SYSTEM : PROCESS RADIATION MONITORING
PLANT IDENTIFICATION NUMBER
RE-1-1735A RE-1-1735B
GENERIC NAME
RADIATION ELEHENT GM TUBE RADIATION ELEMENT GH TUBE
PAGE 009.
......
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 1
SYSTEM : GENERAL USE ELECTRICAL EQUIPMENT
PLANT IDENTIFICATION NUMBER
1X-100A lX-100£! 1X-100C 1X-100D 1X-100E 1X-100F 1X-100G 1X-101A 1X-101B 1X-101D 1X-102A 1X-103 1X-104B 1X-104C 1X-104F 1X-105A 1X-105B 1X-105C 1X-105D 1X-107A
GENERIC NAME
ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION ELECTRICAL PENETRATION
PAGE 010.
COMMONWEALTH EDISON COMPANY ()5-18-1983 PAGE 011.
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 1
SYSTEM : CAM --------------------------------------------------
.PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------RE-1-2419-A RE-1-2419-B S0-1-2499-lA S0-1-2499-lB S0-1-2499-2A S0-1-2499-28
RADIATION DETECTOR RADIATION DETECTOR SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE
COHHONWEALTH EDISON COHPANY
QUAD CITIES UNIT 2
LIST OF EQUIPHENT THAT IS ENVIRONHENTALLY QUALIFIED FOR QUAD CITIES 2
DATE OF ISSUE 05-18-1983
PAGE 001.
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 2
SYSTEM : CORE SPRAY
PLANT IDENTIFICATION NUMBER
FT-2-1461A FT-2-1461B M0-2-1402-4A M0-2-1402-4B PT-2-1460A PT-2-1460B 2-1401A 2-1401B
GENERIC NAME
FLOW TRANSMITTER FLOW TRANSMITTER MOTOR OPERATED GLOBE VALVE MOTOR OPERATED GLOBE VALVE PRESSURE TRANSMITTER PRESSURE TRANSMITTER PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN
PAGE 002.
COMMONWEALTH EDISON COMPANY . . . _()5-18-1983
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 2
SYSTEM : HIGH PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUMBER
LS-2-2351A LS-2-23518 M0-2-2301-35 M0-2-2301-36
GENERIC NAME
LEVEL SIJITCH LEVEL SWITCH MOTOR-OPERATED GATE VALVE MOTOR-OPERATED GATE VALVE
PAGE 003.
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 004.
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 2
SYSTEM : RESIDUAL HEAT REMOVAL
PLANT IDENTIFICATION NUMBER GENERIC NAME
FT-2-1042A FLOW TRANSMITTER FT-2-1042B FLOW TRANSMITTER FT-2-1049A FLOW TRANSMITTER FT-2-1049B FLOW TRANSMITTER FT-2-1051A FLOW TRANSMITTER FT-2-1051B FLOW TRANSMITTER LS-2-4941-2A LEVEL SWITCH <HIGH) LS-2-4941-2B LEVEL SWITCH <HIGH> LS-2-4941-2C LEVEL SWITCH <HIGH> M0-2-1001-16A MOTOR-OPERATED GLOBE VALVE M0-2-1001-16B NOTOR-OPERATED GLOBE VALVE M0-2-1001-18A MOTOR-OPERATED GATE VALVE M0-2-1001-18B MOTOR-OPERATED GATE VALVE M0-2-1001-185A MOTOR OPERATED GATE VALVE M0-2-1001-185B MOTOR .OPERATED bATE VALVE H0-2-1001-19A MOTOR-OPERATED GATE VALVE H0-2-1001-19£1 MOTOR-OPERATED GATE VALVE H0-2-1001-21 MOTOR-OPERATED GATE VALVE M0-2-1001-36A MOTOR-OPERATED GLOBE VALVE H0-2-1001-36B HOTOR-OPERATCD GLODE VALVE M0-2-1001-37A MOTOR-OPERATED GLODE VALVE M0-2-1001-37B MOTOR-OPERATED GLOBE VALVE M0-2-1001-4A MOTOR OPERATED GATE VALVE M0-2-1001-4B MOTOR OPERATED GATE VALVE e M0-2-1001-47 MOTOR-OPERATED GATE VALVE M0-2-1001-7A MOTOR-OPERATED GATE VALVE H0-2-1001-7B MOTOR-OPERATED GATE VALVE M0-2-1001-7C MOTOR-OPERATED GATE VALVE M0-2-1001-7D MOTOR-OPERATED GATE VALVE PT-2-1043A PRESSURE TRANSMITTER PT-2-1043B PRESSURE TRANSMITTER PT-2-1044A PRESSURE TRANSMITTER PT-2-1044B PRESSURE TRANSMITTER 2-1001-65A RHR SERVICE WATER PUMP MOTOR-DRIVEN 2-1001-65£1 RHR SERVICE WATER PUMP MOTOR-DRIVEN 2-1001-65C RHR SERVICE WATER PUMP MOTOR-DRIVEN 2-1001-65D RHR SERVICE WATER PUMP MOTOR-DRIVEN 2-1002A PUMP-MOTOR DRIVEN 2-1002B PUMP-MOTOR DRIVEN 2-1002c PUMP-MOTOR DRIVEN 2-1002D PUHP-HOTOR DRIVEN
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 2
SYSTEM : PRESSURE SUPPRESSION
PLANT IDENTIFICATION NUMBER
LT-2-1641-SA LT-2-1641-SB PT-2-1641-6A PT-2-1641-6B TE-2-1630A TE-2-1630B TE-2-1631A TE-2-1631B
GENERIC NAME
LEVEL TRANSMITTER LEVEL TRANSMITTER PRESSURE TRANSMITTER PRESSURE TRANSMITTER TEMPERATURE ELEMENT <THERMOCOUPLE> TEMPERATURE ELEMENT <THERMOCOUPLE) TEMPERATURE ELEMENT <THERMOCOUPLE> TEMPERATURE ELEMENT <THERMOCOUPLE>
·. c::,
PAGE 005.
COHHONWEALTH EDISON COMPANY 05-18-1983 PAGE 006.
LIST OF EQUIPHENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 2
SYSTEM : CONTAINMENT ISOLATION
PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------. . H0-2-1201-5 H0-2-220-2 H0-2-3702 H0-2-3703 2-203-3A
HOTOR OPERATED GATE VALVE HOTOR OPERATED GLOBE VALVE HOTOR OPERATED VALVE MOTOR OPERATED GATE VALVE S"AFETY RELIEF VALVE AND SOLENOID
COHHONWEALTH EDISON COHPANY 05-18-1983
LIST OF EQUIPHENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 2
SYSTEH : REACTOR RECIRCULATION
PLANT IDENTIFICATION NUMBER
A0-2-220-44 PT-2-647A PT-2-647£1 PT-2-662
GENERIC NAHE
SOLENOID VALVE PRESSURE TRANSHITTER PRESSURE TRANSHITTER PRESSURE TRANSHITTER
PAGE 007.
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 2
SYSTEM : PROCESS RADIATION MONITORING
PLANT IDENTIFICATION NUMBER
RE-2-1735A RE-2-1735B
GENERIC NAME
RADIATION ELEMENT GH TUBE RADIATION ELEMENT GH TUBE
PAGE 008.
COMMONWEALTH EDISON COMPANY ~5-18-1983 PAGE 009.
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 2
SYSTEM : GENERAL USE ELECTRICAL EQUIPMENT
PLANT IDENTIFICATION NUMBER GENERIC NAME
2X-100B ELECTRICAL PENETRATION 2X-100C ELECTRICAL PENETRATION 2X-100E ELECTRICAL PENETRATION 2X-100F ELECTRICAL PENETRATION 2X-100G ELECTRICAL PENETRATION 2X-101A ELECTRICAL PENETRATION 2X-101B ELECTRICAL PENETRATION 2X-101D ELECTRICAL PENETRATION 2X-102B ELECTRICAL PENETRATION 2X-103 ELECTRICAL PENETRATION 2X-104A ELECTRICAL PENETRATION 2X-104B ELECTRICAL PENETRATION 2X-104C ELECTRICAL PENETRATION 2X-104D ELECTRICAL PENETRATION 2X-104F ELECTRICAL PENETRATION 2X-105C ELECTRICAL PENETRATION 2X-106A ELECTRICAL PENETRATION 2X-106B ELECTRICAL PENETRATION 2X-107A ELECTRICAL PENETRATION 2X-107B ELECTRICAL PENETRATION
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR QUAD CITIES 2
SYSTEM i CAM
PLANT IDENTIFICATION NUMBER
RE-2-2419-A RE-2-2419-B
GENERIC NAHE
RADIATION DETECTOR RADIATION DETECTOR
PAGE 010.
PAGE 001.
COHHONWEALTH EDISON COHPANY
DRESDEN UNIT 2
LIST OF EQUIPHENT THAT IS ENVIRONHENTALLY QUALIFIED FOR DRESDEN 2
DATE OF ISSUE 05-18-1983
e COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN
SYSTEM : CORE SPRAY
PLANT IDENTIFICATION HUMBER
FT-2-1461A FT-2-1461B PT-2-1460A PT-2-14608 2-1401A 2-1401B
GENERIC NAME
FLOW TRANSMITTER FLOW TRANSMITTER PRESSURE TRANSMITTER PRESSURE TRANSMITTER PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN
05-18-1983 PAGE 002.
2
COHHONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN 2
SYSTEM : HIGH PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUHBER
LS-2-2351A LS-2-23518 M0-2-2301-35
GENERIC NAME
LEVEL SWITCH LEVEL SWITCH HOTOR OPERATED GATE VALVE
PAGE 003.
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 004.
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN 2
SYSTEM : AUTO DEPRESSURIZATION/ HAIN STEAM
PLANT IDENTIFICATION NUMBER GENERIC NAHE
2-203-3A SAFETY RELIEF VALVE AND SOLENOID
COHHONWEALTH EDISON COHPANY 05-18-1983
LIST OF EQUIPHENT THAT IS ENVIRONHENTALLY QUALIFIED FOR DRESDEN 2
SYSTEM : LOW PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUMBER
FT-2-1542A FT-2-1542B FT-2-1549A FT-2-1549B FT-2-1551A Ff-2-1551B M0-2-1501-llA M0-2-1501-llB M0-2-1501-21A M0-2-1501-21B M0-2-1501-27A M0-2-1501-27B M0-2-1501-28A M0-2-1501-28B M0-2-1501-3A M0-2-1501-3B M0-2-1501-32A M0-2-1501-32B 2-1502A 2-1502B 2-1502C 2-15020
GENERIC NAME
FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER MOTOR OPERATED GATE VALVE HOTOR OPERATED GATE VALVE MOTOR OPERATED STOP CHECK VALVE MOTOR OPERATED STOP CHECK VALVE MOTOR OPERATED GATE VALVE HOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE HOTOR OPERATED GLOBE VALVE MOTOR OPERATED GLOBE VALVE HOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE PUMP-HOTOR DRIVEN PUHP-MOTOR DRIVEN PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN
PAGE 005.
.. COMMONWEALTH EDISON COMPANY
~IST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN
SYSTEM : PRESSURE SUPPRESSION
PLANT IDENTIFICATION NUMBER GENERIC NAME
05-18-1983 PAGE 006.
2
---------------------------------------------------------------------------------------------------LT-2-1641-5A LT-2-1641-5B PT-2-1625 PT-2-1641-6A PT-2-1641-6B
LEVEL TRANSMITTER LEIJEL TRANSMITTER PRESSURE TRANSMITTER PRESSURE TRANSMITTER PRESSURE TRANSMITTER
COHHONWEALTH EDISON COHPANY 05-18-1983
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN 2
SYSTEM : STANDBY GAS TREATMENT
PLANT IDENTIFICATION NUMBER
M0-2/3 7505A M0-2/3-7504A M0-2/3-7504B M0-2/3-7505B M0-2/3-7507A M0-2/3-750711
GENERIC NAME
HOTOR OPERATED DAMPER MOTOR OPERATED DAMPER MOTOR OPERATED DAMPER MOTOR Ol~oRATED DAMPER MOTOR OPERATED DAMPER MOTOR OPERATED DAHPER
PAGE 007.
COHHOHWEALTH EDISON COHPAHY 05-18-1983 PAGE 008.
LIST OF EQUIPHEHT THAT IS EHVIROHHEHTALLY QUALIFIED FOR DRESDEN 2
SYSTEH : COHTAIHHEHT ISOLATION --------------------------------------------------
GENERIC HAHE PLANT IDENTIFICATION NUHBER ---------------------------------------------------------------------------------------------------M0-2-1201-1 i'I0-2-1201-2 M0-2-1201-3 M0-2-220-1 M0-2-220-2 M0-2-3706
MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE HOTOR OPERATED GLOBE VALVE MOTOR OPERATED GLOBE VALVE HOTOR OPERATED GATE VALVE
COHMONWEALTH EDISON COHPANY 05-18-1983 PAGE 009.
'LIST OF EQUIPHENT THAT IS ENVIRONHENTALLY QUALIFIED FOR DRESDEN 2
SYSTEM : REACTOR RECIRCULATION --------------------------------------------------
PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------M0-2-202-7A M0-2-202-7B
• S0-2-220-44
HOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE SOLENOID VALVE
COHHONWEALTH EDISON COMPANY 05-18-1983 PAGE 010.
_LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN 2
SYSTEM : ISOLATION CONDENSER --------------------------------------------------
PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------M0-2-1301-2 M0-2-1301-3
MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 011.
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN 2
SYSTEM : GENERAL USE ELECTRICAL EQUIPMENT
PLANT IDENTIFICATION NUMBER GENERIC NAME
2X-200A ELECTRICAL PENETRATION 2X-200B ELECTRICAL PENETRATION 2X-202B ELECTRICAL PENETRATION 2X-202BB ELECTRICAL PENETRATION 2X-202D ELECTRICAL PENETRATION 2X-202F ELECTRICAL PENETRATION 2X-202J ELECTRICAL PENETRATION 2X-202N ELECTRICAL PENETRATION 2X-202Q ELECTRICAL PENETRATION 2X-202S ELECTRICAL PENETRATION 2X-202lJ ELECTRICAL PENETRATION 2X-203A ELECTRICAL PENETRATION 2X-203B ELECTRICAL PENETRATION 2X-204E ELECTRICAL PENETRATION 2X-204H ELECTRICAL PENETRATION 2X-204P ELECTRICAL PENETRATION 2X-204Q ELECTRICAL PENETRATION 2X-204S ELECTRICAL PENETRATION 2X-204T ELECTRICAL PENETRATION 2X-205E ELECTRICAL PENETRATION
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN 2
SYSTEM : CAM
PLANT IDENTIFICATION NUMBER
RE-2419-A RE-2419-B S0-2-2499-lA S0-2-2499-lB S0-2-2499-2A S0-2-2499-28
GENERIC NAME
RADIATION DETECTOR RADIATION DETECTOR SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE
PAGE 012.
COMMONWEALTH EDISON COMPANY
DRESDEN UNIT 3
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN 3
DATE OF ISSUE 05-18-1983
PAGE 001.
~·~-··:~
COHMONWEALTH EDISON COMPANY 05-18-1983 PAGE 002.
LIST OF EQUIPHENT THAT IS ENVIRONHENTALLY QUALIFIED FOR DRESDEN 3
SYSTEM : CORE SPRAY --------------------------------------------------
PLANT IDENTIFICATION NUMBER GENERIC NAHE ---------------------------------------------------------------------------------------------------FT-3-1461A FT-3-1461B H0-3-1402-24A H0-3-1402-248 H0-3-1402-25A M0-3-1402-258 PT-3-1460A PT-3-1460B 3-1401A 3-14018
FLOW TRANSMITTER FLOW TRANSMITTER MOTOR OPERATED GATE VALVE HOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE HOTOR OPERATED GATE VALVE PRESSURE TRANSMITTER PRESSURE TRANSMITTER PUHP-HOTOR DRIVEN PUMP-MOTOR DRIVEN
COHMONWEALTH EDISON COHPANY 05-18-1983
LIST OF EQUIPHENT THAT IS ENVIRONHENTALLY QUALIFIED FOR DRESDEN 3
SYSTEM : HIGH PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUHBER
LS-3-2351A LS-3-2351B H0-3-2301-35
GENERIC NAHE
LEVEL SWITCH LEVEL SWITCH MOTOR OPERATED GATE VALVE
PAGE 003.
COHHONWEALTH EDISON COMPANY 05-18-1983 PAGE 004.
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOH DRESDEN 3
SYSTEM : AUTO DEPRESSURIZATION/ HAIN STEAH
PLANT IDENTIFICATION NUMBER GENERIC NAHE
3-203-3A SAFETY RELIEF VALVE AND SOLENOID
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN
SYSTEM : LOW PRESSURE COOLANT INJECTiON
PLANT IDENTIFICATION NUMBER
DPT-3-1543A DPT-3-1543B FT-3-1542A FT-3-1542£1 FT-3-1549A FT-3-1549B FT-3-1551A FT-3-1551B M0-3-1501-llA M0-3-1501-11B M0-3-1501-21A M0-3-1501-21B M0-3-1501-27A M0-3-1501-27B M0-3-1501-28A M0-3-1501-28B M0-3-1501-32A M0-3-1501-32B 3-1502A 3-1502B 3-1502C 3-1502D
GENERIC NAME
DIFFERENTIAL PRESSURE TRANSMITTER DIFFERENTIAL PRESSURE TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER FLOW TRANSMITTER MOTOR OPERATED GATE VALVE HOTOR OPERATED GATE VALVE HOTOR OPERATED STOP CHECK VALVE MOTOR OPERATED STOP CHECK VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE HOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN PUMP-MOTOR DRIVEN
05-18-1983 PAGE 005.
3
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 006.
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN 3
SYSTEM : PRESSURE SUPPRESSION
PLANT IDENTIFICATION NUMBER GENERIC NAME ---------------------------------------------------------------------------------------------------LT-3-1626 LT-3-1641-5A LT-3-1641-58 PT-3-1641-6A PT-3-1641-6B
LEVEL TRANSMITTER LEVEL TRANSMITTER LEVEL TRANSMITTER PRESSURE TRANSMITTER PRESSURE TRANSMITTER
J
COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 007.
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN 3
SYSTEM : CONTAINMENT ISOLATION
PLANT IDENTIFICATION NUHBER GENERIC NAME -----------------------------------------------~-------------------------------------------------M0-3-1201-1 M0-3-220-2 M0-3-3702
MOTOR OPERATED GATE VALVE MOTOR OPERATED GLOBE VALVE MOTOR OPERATED VALVE
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN 3
SYSTEM : REACTOR RECIRCULATION
PLANT IDENTIFICATION !>lJHBER
DPIS-3-261-35A DPIS-3-261-358 DPIS-3-261-35C DPIS-3-261-35D DPIS-3-261-35E DPIS-3-261-35F DPIS-3-261-35G DPIS-3-261-35H S0-3-220-44
GENERIC NAME
DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH DIFFERENTIAL PRESSURE INDICATING SWITCH SOLENOID VALVE
PAGE 008.
~ COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN
SYSTEM : ISOLATION CONDENSER
PLANT IDENTIFICATION NUMBER
M0-3-1301-2 M0-3-1301-3
GENERIC NAME
HOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE
05-18-1983 PAGE 009.
3
COHHONWEALTH EDISON COMPANY 05-18-1983 PAGE 010.
LIST OF EQUIPHENT THAT IS ENVIRONHENTALLY QUALIFIED FOR DRESDEN 3
SYSTEH : GENERAL USE ELECTRICAL EQUIPMENT
PLANT IDENTIFICATION NUMBER GENERIC NAME
3X-200C ELECTRICAL PENETRATION 3X-201B ELECTRICAL PENETRATION 3X-202B ELECTRICAL PENETRATION 3X-202BB ELECTRICAL PENETRATION 3X-202D ELECTRICAL PENETRATION 3X-202F ELECTRICAL PENETRATION 3X-202J ELECTRICAL PENETRATION 3X-202N ELECTRICAL PENETRATION 3X-202S ELECTRICAL PENETRATION 3X-202W ELECTRICAL PENETRATION 3X-203B ELECTRICAL PENETRATION 3X-204A ELECTRICAL PENETRATION 3X-204E ELECTRICAL PENETRATION 3X-204H ELECTRICAL PENETRATION 3X-204L ELECTRICAL PENETRATION 3X-204M ELECTRICAL PENETRATION 3X-204N ELECTRICAL PENETRATION 3X-204Q ELECTRICAL PENETRATION 3X-204S ELECTRICAL PENETRATION 3X-205B ELECTRICAL PENETRATION
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT THAT IS ENVIRONMENTALLY QUALIFIED FOR DRESDEN 3
SYSTEM : CAM
PLANT IDENTIFICATION NUMBER
RE-3-2419-A RE-3-2419-B S0-3-2499-lA S0-3-2499-lB S0-3-2499-2A S0-3-2499-28
GENERIC NAME
RADIATION DETECTOR RADIATION DETECTOR SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE SOLENOID VALVE
PAGE 011.
COMMONWEALTH EDISON COMPANY
QUAD CITIES UNIT 1
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED.
DATE OF ISSUE 05-18-1983
THE FOLLOWING REMARKS APPLY TO THIS LIST-
A. COMPONENT REPLACEMENT
B. COMPONENT ENGINEERING ANALYSIS AND/OR TESTING OR EVALUATION
C. ADDITIONAL VENDOR INFORMATION REQUIRED FOR COMPONENT QUALIFICATION
D. CECO COHHITTHENT TO TNSTALL QUALIFl~D ~UMPUN~NI
E. RELOCATION AND/OR SHIEDLING OF COMPONENT <NO QUALIFIED COMPONENT AVAILABLE IN THE HARKET FOR THE REQUIRED RADIATION DOSE>
PAGE 001.
COHHONWEALTH EDISON COHPANY
LIST OF EQUIPHENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 1
SYSTEH: REACTOR PROTECTION
PLANT IDENTIFICATION NUHBER COHPONENT
05-18-1983
QUALIFICATION COHPLETION DATE
PAGE 002.
RE HARKS ---------------------------------------------------------------------------------------------------TE-1-1291-60A TEHPERATURE ELEHENT 05-30-84 A
TE-1-1291-60B TEHPERATURE ELEHENT 05-30-84 A
TE-1-1291-60C TEMPERATURE ELEMENT 05-30-84 A TE-1-1291·-60D TEHPERATURE ELEHENT 05-30-84 A
TE-1-1291-60E TEHPERATURE ELEHENT 05-30-84 A
TE-1-1291-60F TEMPERATURE ELEHENT 05-30-84 A
TE-1-1291-bOG TEHPERATURE ELEHENT 05-30-84 A
TE-1-1291-60H "TEHPERATURE ELEMENT 05-30-84 A
COMHONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 1
SYSTEH: CORE SPRAY
PLANT IDENTIFICATION NUMBER COMPONENT
FS-1-1464A FLOW SWITCH FS-1-14648 FLOW SWITCH M0-1-1402-24A MOTOR OPERATED GATE VALVE H0-1-1402-24B MOTOR OPERATED GATE VALVE M0-1-1402-25A MOTOR OPERATED GATE VALVE M0-1-1402-25B MOTOR OPERATED GATE VALVE H0-1-1402-38A MOTOR OPERATED GATE VALVE i'I0-1-1402-38B HOTOR OPERATED GATE VALVE
05-18-1983
QUALIFICATION COMPLETION DATE
05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84
PAGE 003.
REMARKS
A A A A A A A A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 1
SYSTEM: HIGH PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUMBER COMPONENT
DPIS-1-2352 DIFFERENTIAL PRESSURE INDICATING SWITCH DPIS-1-2353 DIFFERENTIAL PRESSURE INDICATING SWITCH M0-1-2301-4 MOTOR-OPERATED GATE VALVE M0-1-2301-5 MOTOR-OPERATED GATE VALVE M0-1-2301-8 MOTOR OPERATED GATE VALVE PS-1-2389A PRESSURE SWITCH CLOW> PS-1-2389B PRESSURE SWITCH CLOW) PS-1-2389C PRESSURE SWITCH CLOW) PS-1-2389D PRESSURE SWITCH CLOW) TS-1-2370A TEMPERATURE SWITCH TS-1-2370B TEMPERATURE SWITCH TS-1-2370C TEMPERATURE SWITCH TS-1-2370D TEMPERATURE SWITCH TS-1-2371A TEMPERATURE SWITCH TS-1-2371B TEMPERATURE SWITCH TS-1-2371C TEMPERATURE SWITCH TS-1-2371D TEMPERATURE SWITCH TS-1-2372A TEMPERATURE SWITCH TS-1-2372B TEMPERATURE SWITCH TS-1-2372C TEMPERATURE SWITCH TS-1-2372D TEMPERATURE SWITC~ TS-1-2373A TEMPERATURE SWITCH TS-1-2373B TEMPERATURE SWITCH TS-1-2373C TEMPERATURE SWITCH TS-1-2373D TEMPERATURE SWITCH
()5-18-1983
QUALIFICATION COMPLETION DATE
05-30-84 05-30-84 ()5-30-84 ()9-30-83 09-30-83 05-30-84 05-30-84 05-30-84 05-30-84 01-01-84 01-01-84 01-01-84 01-01-84 01-01-84 01-01-84 01-01-84 01-01-84 01-01-84 01-01-84 01-01-84 01-01-84 01-01-84 01-01-84 01-01-84 01-01-84
PAGE 004,
REMARKS
A A A B B A A A A B B B B B B B B B B B B B B B B
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 1
SYSTEM: AUTO DEPRESSURIZATION/ MAIN STEAM
PLANT IDENTIFICATION NUMBER COMPONENT
05-18-1983
QUALIFICATION COMPLETION DATE
PAGE 005.
REMARKS ---------------------------------------------------------------------------------------------------1-203-3B ELECTROMATIC RELIEF VALVE AND SOLENOID 12-30-83 B
1-203-3C ELECTROMATIC RELIEF VALVE AND SOLENOID 12-30-83 B 1-203-3D ELECTROMATIC RELIEF VALVE AND SOLENOID 12-30-83 B
1-203-3E ELECTROMATIC RELIEF VALVE AND SOLENOID 12-30-83 B 1-261-60A SENSOR- ACOUSTIC MONITOR 05-30-84 B 1-261-60B SENSOR- ACOUSTIC MONITOR 05-30-84 B 1-261-60C SENSOR- ACOUSTIC MONITOR 05-30-84 B
1-261-60D SENSOR- ACOUSTIC MONITOR 05-30-84 B 1-261-60E SENSOR- ACOUSTIC HONITOR 05-30-84 B 1-262-61A PREAMPLIFIER ACOUSTIC MONITOR 05-30-84 E 1-262-61B PREAMPLIFIER ACOUSTIC MONITOR 05-30-84 E 1-262-6lC PREAMPLIFIER ACOUSTIC MONITOR 05-30-84 E 1-262-61D PREAMPLIFIER ACOUSTIC MONITOR 05-30-84 E 1-262-61E PREAMPLIFIER ACOUSTIC MONITOR 05-30-84 E
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES
SYSTEM: RESIDUAL HEAT REMOVAL
PLANT IDENTIFICATION NUMBER COMPONENT
DPIS-1-1001-81A DIFFERENTIAL PRESSURE INDICATING SWITCH DPIS-1001-81B DIFFERENTIAL PRESSURE INDICATING SWITCH DPS-1-1001-78A DIFFERENTIAL PRESSURE SWITCH DPS-1-1001-78B DIFFERENTIAL PRESSURE SWITCH M0-1-1001-23A MOTOR-OPERATED GATE VALVE M0-1-1001-23B MOTOR-OPERATED GATE VALVE M0-1-1001-26A MOTOR-OPERATED GATE VALVE M0-1-1001-26B MOTOR-OPERATED GATE VALVE H0-1-1001-28A MOTOR-OPERATED GLOBE VALVE M0-1-1001-28B MOTOR-OPERATED GLOBE VALVE M0-1-1001-29A MOTOR-OPERATED GATE VALVE M0-1-1001-29B MOTOR-OPERATED GATE VALVE M0-1-1001-34A MOTOR-OPERATED GATE VALVE M0-1-1001-34B MOTOR-OPERATED GATE VALVE H0-1-1001-5A MOTOR-OPERATED GLOBE VALVE H0-1-1001-5B MOTOR-OPERATED GLOBE VALVE H0-1-1001-50 MOTOR-OPERATED GATE VALVE M0-1-1001-60 MOTOR-OPERATED GATE VALVE M0-1-1001-63 MOTOR-OPERATED GATE-VALVE
05-18-1983
QUALIFICATION COMPLETION DATE
05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 09-30-83 09-30-83 05-30-84
PAGE 006.
REMARKS
A A A A A A A A A A A A A A A A B B A
COHHONWEALTH EDISON COHPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 1
SYSTEH: PRESSURE SUPPRESSION ··--------------------------------------------
PLANT IDENTIFICATION NUHBER COHPOHEHT
05-18-1983
QUALIFICATION COMPLETION DATE
PAGE 007.
REHARKS
---------------------------------------------------------------------------------------------------PS-1-1622A PS-1-16228 S0-1-1601-50A S0-1-1601-508
PRESSURE SWITCH PRESSURE SWITCH SOLENOID VALVE SOLENOID VALVE
05-30-84 05-30-84 05-30-84 05-30-84
A A A A
COHHONWEALTH EDISON COHPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 1
SYSTEH: STANDBY GAS TREATHENT
PLANT IDENTIFICATION NUHBER COHPONENT
FSL-l/2-7541-33A FLOW SWITCH LOIJ FSL-l/2-7541-33B FLOW SWITCH LOIJ FSL·-l/2-7541-8A FLOW SWITCH LOIJ FSL-l/2-7541-8B FLOW SWITCH LOW HO-l/2-7504A HOTOR OPERATED DAMPER HO-l/2-7504B HOTOR OPERATED DAMPER MO-l/2-7505A HOTOR OPERATED DAMPER MO-l/2-7505B MOTOR OPERATED DAHPER H0-1/2-7507A MOTOR OPERATED DAHPER HO-l/2-7507B MOTOR OPERATED DAMPER TSH-1/2-7541-llA TEMPERATURE SWITCH HIGH TSH-1/2-7541-llB TEMPERATURE SWITCH HIGH l/2-7503A ELECTRIC AIR HEATER l/2-7503B ELECTRIC AIR HEATER l/2-7506A MOTOR-EXHAUST FAN l/2-7506B MOTOR-EXHAUST FAN 2212-29A LOCAL CONTROL PANEL 2212-29B LOCAL CONTROL PANEL
05-18-1983
QUALIFICATION COHPLETION DATE
05-30-84 05-30-84 05-30-84 05-30-84 03-31-85 03-31-85 03-31-85 03-31-85 03-31-05 03-15-05 05-30-04 05-30-04 00-01-03 00-01-03 05-30-04 05-30-04 05-30-04 05-30-04
PAGE 008.
REHARKS
A A A A A A A A A A A A B B A A E E
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES
SYSTEM: SERVICE WATER
PLANT IDENTIFICATION NUMBER COMPONENT
1-5746A 1-5746B 1-5748A 1-5748B
ROOM COOLER FAN MOTOR ROOM COOLER FAN MOTOR ROOM COOLER FAN MOTOR ROOM COOLER FAN MOTOR
()5-18-1983
QUALIFICATION COMPLETION DATE
05-30-84 ()5-30-84 ()5-30-84 ()5-30-84
PAGE 009.
REMARKS
A A A A
- COHHONWEALTH EDISON COMPANY 05-18-1983 PAGE 010.
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 1
SYSTEM: CONTAINMENT ISOLATION ---------------------------------------------
QUALIFICATION PLANT IDENTIFICATION NUHBER COHPONENT COMPLETION DATE REHARl<S ---------------------------------------------------------------------------------------------------110-1-1201-2 HOTOR OPERATED GATE VALVE 09-30-83 B H0-1-3706 MOTOR-OPERATED GATE VALVE 09-30-83 B H0-1-220-1 HOTOR OPERATED GLOBE VALVE 09-30-83 B S0-1-203-18 HSIV AND SOLENOID FDR AIR OPERATOR 06-30-84 B S0-1-203-lC HSIV AND SOLENOID FOR AIR OPERATOR 06-30-84 B S0-1-203-lD HSIV AND SOLENOID FDR AIR OPERATOR 06-30-84 B S0-1-203-2A HSIV AND SOLENOID FOR AIR OPERATOR 06-30-84 B S0-1-203-2B HSIV AND SOLENOID FOR AIR OPERATOR 06-30-84 B S0-1-203-2C HSIV AND SOLENOID FOR AIR OPERATOR 06-30-84 8 S0-1-203-2D HSIV AND SOLENOID FOR AIR OPERATOR 06-30-84 B S0-1-203-lA HSIV AND SOLENOID FOR AIR OPERATOR 06-30-84 B I
TS-1-261-15A TEHPERATURE SWITCH 05-30-84 8 TS-1-261-158 TEHPERATURE SWITCH 05-30-84 8 TS-1-261-lSC TEHPERATURE SWITCH 05-30-84 8 TS-1-261-15D TEHPERATURE SWITCH 05-30-84 B TS-1-261-16A TEMPERATURE SWITCH 05-30-84 B TS-1-261-168 TEHPERATURE SWITCH 05-30-84 8 TS-1-261-16C TEMPERATURE SWITCH 05-30-84 B TS-1-261-16D TEHPERATURE SWITCH 05-30-84 B TS-1-261-17A TEHPERATURE SWITCH 05-30-84 8 TS-1-261-178 TEHPERATURE SWITCH 05-30-84 B TS-1-261-17C TEMPERATURE SWITCH 05-30-84 8 TS-1-261-17D TEHPERATURE SWITCH 05-30-84 8 TS-1-261-18A TEMPERATURE SWITCH 05-30-84 B
e TS-1-261-188 TEHPERATURE SWITCH 05-30-84 B TS-1-261-18C TEHPERATURE SWITCH 05-30-84 B TS-1-261-18D TEHPERATURE SWITCH 05-30-84 8
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 1
SYSTEH: REACTOR RECIRCULATION
PLANT IDENTIFICATION NUMBER COMPONENT
LIS-1-263-58A LEVEL INDICATOR SWITCH LIS-1-263-588 LEVEL INDICATOR SWITCH LI"TS-1-263-73A LEVEL INDICATING TRANSMITTER SWITCH LITS-1-263-738 LEVEL INDICATING TRANSMITTER SWITCH M0-1-202-5-A MOTOR OPERATED GATE VALVE&BRAKE H0-1-202-5-B i'IOTOR OPERATED GATE VALVE&BRAKE POS-1-220-44 POSITION SWITCH
05-18-1983
QUALIFICATION COMPLETION DATE
05-30-84 05-30-84 05-30-84 •:>5-30-84 05-30-84 05-30-84 05-30-84
PAGE 011.
REMARKS
A A A A A A A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES
SYSTEM: STANDBY AC POWER
PLANT IDENTIFICATION NUMBER COMPONENT
HCC 18-1A 480 V HCC HCC 18-1B 480 V HCC HCC 18-3 480 V HCC MCC 18/19-5 480 V HCC HCC 19-1 480 V HCC MCC 19-3 480 V HCC HCC 19-6 480 V HCC
05-18-1983
QUALIFICATION COMPLETION DATE
12-31-83 12-31-83 12-31-83 12-31-83 12-31-83 12-31-83 12-31-83
PAGE 012.
REMARKS
B B B B B B B
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPHEHT NIH PRESENTLY QUALIFIED FOR QUAD CITIES
SYSTEM: STANDBY l)f: <'iflrJER.
PLANT IDENTIFICATION NUMBER COMPONENT
05-18-1983
Q~tAC.J'.f lC.itiHl7N cm<.l?\.ETI~ {)ATli:
125 V DCDP 1 125 V DC REACTOR BLDG DISTRIBUTION PAf-!EL 09-30-83
PAGE 013.
REHARKS
.B
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 1
SYSTEM: REACTOR CORE ISOLATI~~ COOLING
PLANT IDENTIFICATION NUMBER COMPONENT
M0-1-1301-16 MOTOR OPERATED GATE VALVE M0-1-1301-17 MOTOR OPERATED GATE VALVE TS-1-1360 15D TEMPERATURE SWITCH TS-1-1360-14A TEMPERATURE SWITCH TS-1-1360-14B TEMPERATURE SWITCH TS-1-1360-14C TEMPERATURE SWITCH TS-1-1360-14D TEMPERATURE SWITCH TS-1-1360-15A TEMPERATURE SWITCH TS-1-1360-15B TEMPERATURE SWITCH TS-1-1360-15C TEMPERATURE SWITCH TS-1-1360-16A TEMPERATURE SWITCH TS-1-1360-16B TEMPERATURE SWITCH TS-1-1360-16C TEMPERATURE SWITCH TS-1-1360-16D TEMPERATURE SWITCH TS-1-1360-17A TEMPERATURE SWITCH TS-1-1360-17B TEMPERATURE SWITCH TS-1-1360-17C TEMPERATURE SWITCH TS-1-1360-17D TEMPERATURE SWITCH
05-18-1983
QUALIFICATION COMPLETION DATE
09-30-83 09-30-83 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84 05-30-84
PAGE Jl4. ! . I
REMARKS
B B B B B B B B B B B B B B B B B B
e
---- ----- ----------
COHHONWEALTH EDISON COHPANY 05-18-1983
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 1
SYSTEM: GENERAL USE ELECTRICAL EQUIPHENT
PLANT IDENTIFICATION NUMBER .COMPONENT QUALIFICATION COMPLETION DATE
CABLE ANHYDREX XX PLASTEX INSU & JKT 05-30-84 CABLE ANHYDREX XX PLASTEX INSU & JKT 05-30-84 CABLE BUTYL RBR INSU POLYVN CHLORIDE JKT 05-30-84 CABLE BUTYL RBR INSU POLYVN CHLORIDE JKT 05-30-84 CABLE BUTYL RBR INSU POLYVN CHLORIDE JKT 05-30-84 CABLE CROSSLINKED POLYOLEFIN W-16 AWG DRN & JKT 09-30-83 CABLE CSPE INSUL.,POLYEST ALUHINUH SHLD. 09-30-83 CABLE EPDH I INSUL. W/HAPAL COND. JKT 09-30-83 CABLE EPDH I INSUL. W/HAPAL COND. JKT 09-30-83 CABLE EPDM II INSUL. W/HAPA COND. JKT 09-30-83 CABLE EPDH INSUL. W/HAPALON JKT DRN. AND SHLD. 09-30-83 CABLE EPR INSUL. CSPE JKT. 09-30-83 CABLE EPR W/CSPE JKT., FR SHLD, DRN WIRE AND OV 09-30-83 CABLE EPR W/CSPE JKT., FR SHLD, DRN WIRE AND OV 09-30-83 CABLE EPR W/NEOPRENE INSUL. AND JKT. 09-30-83 CABLE FR-EPDM AND 16 AWG AND HYPALON JKT. 09-30-83 CABLE MULTI PAIR WITH OVERALL SH CU CON 09-30-83 CABLE OKONITE EPR INSUL. WITH OKO COVER AND OVE 09-30-83 CABLE POLY NYLON INSU SHLD & PLASTEX INSTR 05-30-84 CABLE RBR INSU POLYV CHLORIDE JACKET 05-30-84 CABLE SINGLE/MULTIPAIR CABLE WITH OVERALL SH 05-30-84 CABLE SR INSUL. WITH GLASSBRAID AND SIL. SAT. A 09-30-83 CABLE SWITCHBOARD-TYPE SIS tSI 57275 VULKENE 05-30-84 CABLE XLPE INSUL. WITH NEOPRENE JKT. 09-30-83 CABLE 3 TW WITH OVERALL SH 05-30-84 CABLE <SHIELDED> EPR INSUL. EXTRUDED SEHI. COND. CSPE INSU 09-30-83 79-0lB-1 TERMINAL BLOCKS <TYPICAL 2 UNITS> 05-30-84 79-0lB-2 TERHINAL BLOCKS <TYPICAL 2 UNITS> 05-30-84 79-0lB-3 TERMINAL BLOCKS <TYPICAL 2 UNITS> 05-30-84 79-0lB-4 TERHINAL BLOCKS <TYPICAL 2 UNITS> 05-30-84 79-0lB-5 TERMINAL BLOCKS <TYPIC~L 2 UNITS> 05-30-84 79-0lB-6 TERHINAL BLOCKS <TYPICAL 2 UNITS> 05-30-84 79-01R-7 TERMINAL BLOCKS <TYPICAL 2 UNITS> 05-30-84 79-0!B-8 TERMWAL BLOCl<S <TYPICAL 2 Utl!T6) 05-30-84
PAGE 015.
REMARKS
B B B B B B B B B B B B B B B B B B B B B B B B B B A A B B B B A A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES
SYSTEM: CAM
PLANT IDENTIFICATION NUMBER COMPONENT
PT-1-2421-A PT-1-2421-B RE-1-2418-C RE-1-2418-D
PRESSURE TRANSMITTER PRESSURE TRANSMITTER RADIATION DETECTOR RADIATION DETECTOR
05-18-1983
QUALIFICATION COMPLETION DATE
06-30-84 06-30-84 05-30-84 05-30-84
PAGE 016.
REMARKS
B B c c
COMMONWEALTH EDISON COMPANY
QUAD CITIES UNIT 2
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED
DATE OF ISSUE 05-18-1983
THE FOLLOWING REMARKS APPLY TO THIS LIST-
A. COMPONENT REPLACEMENT
B. COMPONENT ENGINEERING ANALYSIS AND/OR TESTING OR EVALUATION
C. ADDITIONAL VENDOR INFORMATION REQUIRED FOR COMPONENT QUALIFICATION
D. CECO COMMITTMENT TO INSTALL QUALIFIED COMPONENT
E. RELOCATION AND/OR SHIEDLING OF COMPONENT <NO QUALIFIED COMPONENT AVAILABLE IN THE MARKET FOR THE REQUIRED RADIATION DOSE>
PAGE 001.
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 2
SYSTEM: REACTOR PROTECTION
PLANT IDENTIFICATION NUHFER COMPONENT
05-18-1983
QUALIFICATION COMPLETION DATE
PAGE 002.
REMARKS ---------------------------------------------------------------------------------------------------TE-2-1291-60A TEMPERATURE ELEMENT 03-15-85 A
TE-2-1291-60F TEMPERATURE ELEMENT 03-15-85 A
TE-2-1291-60C TEMPERATURE ELEMENT 03-15-85 A
TE-2-1291-60D TEMPERATURE ELEMENT 03-15-85 A
TE-2-1291-60E TEMPERATURE ELEMENT 03-15-85 A
TE-2-1291-60F TEMPERATURE ELEMENT 03-15-85 A
TE-2-1291-60G TEMPERATURE ELEMENT 03-15-85 A
TE-2-1291-60H TEMPERATURE ELEMENT 03-15-85 A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 2
SYSTEM: CORE SPRAY
PLANT IDENTIFICATION NUMBER COMPONENT
FS-2-1464A FLOW SWITCH FS-2-14648 FLOW SWITCH H0-2-1402-24A MOTOR OPERATED GATE VALVE M0-2-1402-248 MOTOR OPERATED GATE VALVE M0-2-1402-25A MOTOR OPERATED GATE VALVE M0-2-1402-25B MOTOR OPERATED GATE VALVE H0-2-1402-38A MOTOR OPERATED GATE VALVE M0-2-1402-38B i"IOTOR OPERATED GATE VALVE
05-18-1983
QUALIFICATION COMPLETION DATE
03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85
PAGE 003.
REMARKS
A A A A A A A A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 2
SYSTEM: HIGH PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUMBER COMPONENT
DPIS-2-2352 DIFFERENTIAL PRESSURE INDICATING SWITCH DPIS-2-2353 DIFFERENTIAL PRESSURE INDICATING SWITCH M0-2-2301-4 MOTOR-OPERATED GATE VALVE M0-2-2301-5 MOTOR-OPERATED GATE VALVE M0-2-2301-8 MOTOR OPERATED GATE VALVE PS-2-2389A PRESSURE SWITCH CLOW) PS-2-2389B PRESSURE SWITCH CLOW> PS-2-2389C PRESSURE SWITCH (LOW> PS-2-2389D PRESSURE SWITCH <LOW> TS-2-2370A TEMPERATURE SWITCH TS-2-2370B TEMPERATURE SWITCH TS-2-237E>C TEMPERATURE SWITCH TS-2-2370D TEMPERATURE SWITCH TS-2-2371A TEMPERATURE SWITCH TS-2-2371B TEMPERATURE SWITCH TS-2-2371C TEMPERATURE SWITCH TS-2-2371D TEMPERATURE SWITCH TS-2-2372A TEMPERATURE SWITCH TS-2-2372B TEMPERATURE SWITCH TG ~ ~Q7:!C TEi:MPF.l?ATlll?F !ilHTr.H TS-2-2372D TEMPERATURE SWITCH TS-2-2373A TEMPERATURE SWITCH TS-2-2373B TEMPERATURE SWITCH TS-2-2373C TEMPERATURE SWITCH
e TS-2-2373D TEMPERATURE SWITCH
05-18-1983
QUALIFICATION COMPLETION DATE
03-15-85 03-15-85 03-15-85 09-30-83 09-30-83 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 •:>3-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 Q3-i5-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85
PAGE 004.
REMARl<S
A A A B B A A A A B B B B B B B B B B B B B B B B
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 2
SYSTEM: AUTO DEPRESSURIZATION/ HAIN STEAM
PLANT IDENTIFICATION NUMBER COMPONENT
2-203-3B ELECTROMATIC RELIEF VALVE AND SOLENOID 2-203-3C ELECTROMATIC RELIEF VALVE AND SOLENOID 2-203-3D ELECTROMATIC RELIEF VALVE AND SOLENOID 2-203-3E ELECTROMATIC RELIEF VALVE AND SOLENOID 2-261-60A SENSOR- ACOUSTIC MONITOR 2-261-60B SENSOR- ACOUSTIC MONITOR 2-261-60C SENSOR- ACOUSTIC MONITOR 2-261-60D SENSOR- ACOUSTIC MONITOR 2-261-60E SENSOR- ACOUSTIC MONITOR 2-262-61A PREAMPLIFIER ACOUSTIC MONITOR 2-262-61B PREAMPLIFIER ACOUSTIC MONITOR 2-262-61C PREAMPLIFIER ACOUSTIC MONITOR 2-262-61D PREAMPLIFIER ACOUSTIC MONITOR 2-262-61E PREAMPLIFIER ACOUSTIC MONITOR
05-18-1983
QUALIFICATION COMPLETION DATE
12-30-83 12-30-83 12-30-83 12-30-83 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85
PAGE 005.
REMARKS
B B B B B B B B B
B
B B B B
COHHONWEALTH EDISON COHPANY
LIST OF EQUIPHENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 2
SYSTEH: RESIDUAL HEAT REMOVAL
PLANT IDENTIFICATION NUHBER COHPONENT
05-18-1983
QUALIFICATION COHPLETION DATE
PAGE 006.
REHARl<S
---------------------------------------------------------------------------------------------------DPIS-2-1001-81A DIFFERENTIAL PRESSURE INDICATING SWITCH 03-15-85 A
DPIS-2-1001-81B DIFFERENTIAL PRESSURE INDICATING SWITCH 03-15-85 A DPS-2-1001-78A DIFFERENTIAL PRESSURE SWITCH 03-15-85 A DPS-2-1001-788 DIFFERENTIAL PRESSURE SWITCH 03-15-85 A
H0-2-1001-23A MOTOR-OPERATED GATE VALVE 03-15-85 A
H0-2-1001-23B MOTOR-OPERATED GATE VALVE 03-15-85 A H0-2-1001-26A MOTOR-OPERATED GATE VALVE 03-15-85 A
H0-2-1001-26B MOTOR-OPERATED GATE VALVE 03-15-85 A
H0-2-1001-28A HOTOR-OPERATED GLOBE VALVE 03-15-85 A H0-2-1001-28B MOTOR-OPERATED GLOBE VALVE 03-15-85 A H0-2-100-1-29A MOTOR-OPERATED GATE VALVE 03-15-85 A
H0-2-1001-29B MOTOR-OPERATED GATE VALVE 03-15-85 A H0-2-1001-34A MOTOR-OPERATED GATE VALVE 03-15-85 A
H0-2-1001-348 HOTOR-OPERATED GATE VALVE 03-15-85 A
H0-2-1001-5A MOTOR-OPERATED GLOBE VALVE 03-15-85 A H0-2-1001-5B MOTOR-OPERATED GLOBE VALVE 03-15-85 A H0-2-1001-50 MOTOR-OPERATED GATE VALVE 09-30-84 B
H0-2-1001-60 HOTOR-OPERATED GATE VALVE 09-30-84 B
H0-2-1001-f.::l MOTOR-OPERATED GATE-VALVE 03-15-85 A
COHHONWEALTH EDISON COHPANY
LIST OF EQUIPHENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 2
SYSTEH: PRESSURE SUPPRESSION
PLANT IDENTIFICATION NUMBER COMPONENT
PS-2-1622A PS-2-1622B S0-2-1601-50A S0-2-1601-509
PRESSURE SWITCH PRESSURE SWITCH SOLENOID VALVE SOLENOID VALVE
05-18-1983
QUALIFICATION COHPLETION DATE
03-15-85 03-15-85 03-15-85 03-15-85
PAGE 007.
REHARl<S
A A A A
COHHONWEALTH EDISON COHPANY
LIST OF EQUIPHENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 2
SYSTEM: SERVICE WATER
PLANT IDENTIFICATION NUHBER COMPONENT
05-18-1983
QUALIFICATION COHPLETION DATE
PAGE 008.
REHARKS ---------------------------------------------------------------------------------------------------2-5746A 2-5746B 2-5748A 2-5748B
ROOM COOLER FAN HOTOR ROOH COOLER FAN MOTOR ROOM COOLER FAN HOTOR ROOM COOLER FAN MOTOR
03-15-85 03-15-85 03-15-85 03-15-85
A A A A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 2
SYSTEM: CONTAINMENT ISOLATION
PLANT IDENTIFICATION NUHBER COMPONENT
A0-2-203-lA A0-2-203-lB A0-2-203-lC A0-2-203-lD A0-2-203-2A A0-2-203-2B A0-2-203-2C A0-2-203-2D H0-2-1201-2 "0-2-220-1 "0-2-3706 TS-2-261-15A TS-2-261-15B TS-2-261-15C TS-2-261-15D TS-2-261-16A TS-2-261-16B TS-2-261-16C TS-2-261-16D TS-2-261-17A TS-2-261-17B TS-2-261-17C TS-2-261-17D TS-2-261-18A TS-2-261-18B TS-2-261-18C TS-2-261-180
HSIV AND SOLENOID FOR AIR OPERATOR HSIV AND SOLENOID FOR AIR OPERATOR HSIV AND SOLENOID FOR AIR OPERATOR HSIV AND SOLENOID FOR AIR OPERATOR MSIV AND SOLENOID FOR AIR OPERATOR HSIV AND SOLENOID FOR AIR OPERATOR HSIV AND SOLENOID FOR AIR OPERATOR HSIV AND SOLENOID FOR AIR OPERATOR MOTOR OPERATED GATE VALVE MOTOR OPERATED .. GLOBE VALVE MOTnR-OPERATED.GATE VALVE TE"PERATURE.SWITCH TEMPERATURE SWITCH TE"PERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH TEMPERATURE SWITCH
05-18-1983
QUALIFICATION COMPLETION DATE
06-30-84 06-30-84 06-30-84 06-30-84 06-30-8-4 06-30-84 06-30-84 06-30-84 09-30-83 09-30-83 09-30-83 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85
PAGE 009.
REMARKS
B B B B B B B B B B B A A A A A A A A fl A A A A A A A
------------~~-~ -----
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 2
SYSTEM: REACTOR RECIRCULATION
PLANT IDENTIFICATION NUMBER COMPONENT
LIS-2-263-58A LEVEL INDICATOR SWITCH LIS-2-263-58B LEVEL INDICATOR SWITCH LITS-2-263-73A LEVEL INDICATING TRANSMITTER SWITCH LITS-2-263-73B LEVEL INDICATING TRANSMITTER SWITCH M0-2-202-5-A MOTOR OPERATED GATE VALVE & BRAKE M0-2-202-5-B MOTOR OPERATED GATE VALVE & BRAKE POS-2-220-44 POSITION SWITCH POS-2-220-45 POSITION SWITCH
()5-18-1983
QUALIFICATION COMPLETION DATE
()3-15-85 ()3-15-85 ()3-15-85 ()3-15-85 03-15-84 ()3-15-84 03-15-85 ()3-15-85
PAGE 010.
REMARKS
A A A A A A A A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 2
SYSTEM: STANDBY AC POWER
PLANT IDENTIFICATION NUMBER COMPONENT
MCC 28-lA 480 V HCC HCC 28-lB 480 V HCC HCC 28-3 480 V HCC HCC 28129-5 480 V HCC HCC 29-1 480 V HCC HCC 29-3 480 V HCC MCC 29-6 480 V HCC
05-18-1983
QUALIFICATION COMPLETION DATE
07-08-83 07-08-83 07-08-83 07-08-83 07-08-83 07-08-83 07-08-83
PAGE 011.
RE HARKS
B B B B B B B
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 2
SYSTEM: STANDBY DC POWER
PLANT IDENTIFICATION NUMBER COMPONENT
05-18-1983
QUALIFICATION COMPLETION DATE
PAGE 012.
REMARKS ---------------------------------------------------------------------------------------------------125 V DCDP 1 125 V DC REACTOR BLDG DISTRIBUTION PANEL 09-30-83 B
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 2
SYSTEM: REACTOR CORE ISOLATION COOLING
PLANT IDENTIFICATION NUMBER COMPONENT
M0-2-1301-16 MOTOR OPERATED GATE VALVE M0-2-1301-17 MOTOR OPERATED GATE VALVE TS-2-1360-14A TEMPERATURE SWITCH TS-2-1360-14B TEMPERATURE SWITCH TS-2-1360-14C TEMPERATURE SWITCH TS-2-1360-140 TEMPERATURE SWITCH TS-2-1360-15A TEMPERATURE SWITCH TS-2-1360-15B TEMPERATURE SWITCH TS-2-1360-15C TEMPERATURE SWITCH TS-2-1360-150 TEMPERATURE SWITCH TS-2-1360-16A TEMPERATURE SWITCH TS-2-1360-16B TEMPERATURE SWITCH TS-2-1360-16C TEMPERATURE SWITCH TS-2-1360-160 TEMPERATURE SWITCH TS-2-1360-17A TEMPERATURE SWITCH TS-2-1360-17B TEMPERATURE SWITCH TS-2-1360-17C TEMPERATURE SWITCH TS-2-1360-17D TEMPERATURE SWITCH
()5-18-1983
QUALIFICATION COMPLETION DATE
()9-30-83 ()9-30-83 ()3-15-85 ()3-15-85 03-15-85 ()3-15-85 ()3-15-85 ()3-15-85 ()3-15-85 03-15-85 03-15-85 ()3-15-85 ()3-15-85 ()3-15-85 03-15-85 ()3-15-85 03-15-85 ()3-15-85
PAGE 013.
REMARKS
B B B B B B B B B B B B B B B B B B
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 2
SYSTEM: GENERAL USE ELECTRICAL EQUIPMENT
PLANT IDENTIFICATION NUMBER COMPONENT
05-18-1983
QUALIFICATION COMPLETION DATE
PAGE 014.
REMARKS ---------------------------------------------------------------------------------------------------CABLE ANHYDREX XX PLASTEX INSU & JKT 03-15-85 B
CABLE ANHYDREX XX PLASTEX INSU & JKT 03-15-85 B
CABLE BUTYL RBR INSU POLYVN CHLORIDE JKT 03-15-85 B CABLE BUTYL RBR INSU POLYVN CHLORIDE JKT 03-15-85 B
CABLE BUTYL RBR INSU POLYVN CHLORIDE JKT 03-15-85 B CABLE CROSSLINKED POLYFIN W-16 AWG DRN & JKT 09-30-83 B
CABLE CSPE INSUL., POLYESTER ALUMINUM SHLD. AND 09-30-83 B CABLE EPDM I INSUL. W/HAPALON COND. JKT AND OVE 09-30-83 B CABLE EPDM I INSUL. W/HAPALON COND. JKT AND OVE 09-30-83 B CABLE EPDM II INSUL. W/HAPALON COND. JKT. AND 0 09-30-83 B
CABLE EPDM INSUL. W/HAPALON JKT DRN. AND SHLD. 09-30-83 B
CABLE EPR INSUL. CSPE JKT. 09-30-83 B CABLE EPR W/CSPE JKT., FR SHLD, DRN WIRE AND OV 09-30-83 B
CABLE EPR IJ/CSPE JKT., FR SHLD, DRN WIRE AND av 09-30-83 B CABLE EPR W/NEOPRENE INSUL. AND JKT. 09-30-83 B
CABLE FR-EPDM AND 16 AWG AND HYPALON JKT. 09-30-83 B
CABLE MULTI PAIR WITH OVERALL SH CO-CON 03-15-85 B
CABLE OKONITE EPR INSUL. WITH OKO COVER AND OVE 09-30-83 B CABLE POLY NYLON INSU SHLD & PLASTEX INSTR 03-15-85 B CABLE POLYETH INSU POLYV CHLORIDE JKI OJ-l::i-8::i B CABLE RBR INSU POLYV CHLORIDE JACKET 03-15-85 B CABLE SINGLE/MULTIPAIR CABLE WITH OVERALL SH 03-15-85 B
CABLE SR INSUL. WITH GLASSBRAID AND SIL. SAT. A 09-30-83 B CABLE SWITCHBOARD-TYPE SIS tSI 57275 VULKENE 03-15-85 B CABLE XLPE INSUL. WITH NEOPRENE JKT. 09-30-83 B CABLE 3 TW WITH OVERALL SH 03-15-85 B CABLE <SHIELDED> EPR INSUL. COPPER DRN WIRES CHLORINATED P 09-30-83 B
CABLE <SHIELDED> EPR INSUL. EXTRUDED SEMI COND. CSPE INSUL 09-30-83 B
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR QUAD CITIES 2
SYSTEM: CAM
PLANT IDENTIFICATION NUMBER COMPONENT
HS-2-2402-C HYDROGEN SENSOR HS-2-2402-D HYDROGEN SENSOR PT-2-2421-A PRESSURE TRANSMITTER PT-2-2421-B PRESSURE TRANSMITTER RE-2-2418-A RADIATION DETECTOR RE-2-2418-B RADIATION DETECTOR RE-2-2418-C RADIATION DETECTOR RE-2-2418-D RADIATION DETECTOR
05-18-1983
QUALIFICATION COMPLETION DATE
01-01-84 01-01-84 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85 03-15-85
PAGE 015.
REMARKS
D D c c c c c c
COMMONWEALTH EDISON COMPANY
DRESDEN UNIT 2
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED
DATE OF ISSUE 05-18-1983
THE FOLLOWING REMARKS APPLY TO THIS LIST-
A. COMPONENT REPLACEMENT
B. COMPONENT ENGINEERING ANALYSIS AND/OR TESTING OR EVALUATION
C. ADDITIONAL VENDOR INFORMATION REQUIRED FOR COMPONENT QUALIFICATION
D. CECO COMMITTMENT TO INSTALL QUALIFIED COMPONENT
E. RELOCATION AND/OR SHIEDLING OF COMPONENT <NO OUALIFIED COMPONENT AVAILABLE IN THE MARKET FOR THE REQUIRED RADIATION DOSE>
PAGE 001.
COMMONWEALTH EDISON .COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 2
SYSTEM: REACTOR PROTECTION
PLANT IDENTIFICATION NUMBER COMPONENT
TE-2-1291-60A TEMPERATURE ELEMENT TE-2-1291-608 TEMPERATURE ELEMENT TE-2-1291-60C TEMPERATURE ELEMENT TE-2-1291-60D TEMPERATURE ELEMENT TE-2-1291-60E TEMPERATURE ELEMENT TE-2-1291-60F TEMPERATURE ELEMENT TE-2-1291-60G TEMPERATURE ELEMENT TE-2-1291-60H TEMPERATURE ELEMENT
05-18-1983
QUALIFICATION COMPLETION DATE
12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84
PAGE 002.
REMARKS
A A A A A A A A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 2
SYSTEM: CORE SPRAY
PLANT IDENTIFICATION NUMBER COMPONENT
()5-18-1983
QUALIFICATION COMPLETION DATE
PAGE 003.
REMARKS ---------------------------------------------------------------------------------------------------FS-2·-1464A FLOW SWITCH 12-01-84 A FS-2-1464B FLOW SWITCH 12-01-84 A M0-2-1402-24A MOTOR OPERATED GATE VALVE 12-01-84 A M0-2-1402-24B MOTOR OPERATED GATE VALVE 12-01-84 A M0-2-1402-25A MOTOR OPERATED GATE VALVE 12-01-84 A M0-2-1402-259 MOTOR OPERATED GATE VALVE 12-01-84 A M0-2-1402-3BA MOTOR OPERATED GATE VALVE 12-01-84 A M0-2-1402-3BB MOTOR OPERATED GATE VALVE 12-01-84 A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 2
SYSTEM: HIGH PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUMBER COMPONENT
DPIS-2-2352 DIFFERENTIAL PRESSURE INDICATING SWITCH DPIS-2-2353 DIFFERENTIAL PRESSURE INDICATING SWITCH M0-2-2301-4 MOTOR OPERATED GATE VALVE M0-2-2301-5 MOTOR OPERATED GATE VALVE M0-2-2301-8 MOTOR OPERATED GATE VALVE PS-2-2389A PRESSURE SWITCH PS-2-2389B PRESSURE SWITCH PS-2-2389C PRESSURE SWITCH PS-2-2389D PRESSURE SWITCH TS-2-2370A TEMPERATURE SWITCH TS-2-237<;\B TEMPERATURE SWITCH TS-2-2370C TEMPERATURE SWITCH TS-2-2370D TEMPERATURE SWITCH TS-2-2371A TEMPERATURE SWITCH TS-2-2371B TEMPERATURE SWITCH TS-2-2371C "TEMPERATURE SWITCH TS-2-2371D TEMPERATURE SWITCH TS-2-2372A TEMPERATURE SWITCH TS-2-2372B "Tl!HPER,t,TURC BWITCH TS-2-2372C TEMPERATURE SWITCH TS-2-2372D TEMPERATURE SWITCH TS-2-2373A TEMPERATURE SWITCH TS-2-2373B TEMPERATURE SWITCH TS-2·-2373C TEMPERATURE SWITCH
e TS-2-2373D TEMPERATURE SWITCH
•:>5-18-1983
QUALIFICATION COMPLETION DATE
12-01-84 12-01-84 12-01-84 09-30-83 09-30-83 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84
PAGE 004.
REMARKS
A A A B B A A A A It B B B B B B B It B :B B B B B B
- COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 005.
LIST.OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 2
SYSTEM: AUTO DEPRESSURIZATION/ HAIN STEAM ---------------------------------------------
QUALIFICATION PLANT IDENTIFICATION NUMBER COMPONENT COMPLETION DATE REHARl<S ---------------------------------------------------------------------------------------------------TS-2-261-15A TEMPERATURE SWITCH 12-01-84 B TS-2-261-15B TEMPERATURE SWITCH 12-01-84 B TS-2-261-15C TEMPERATURE SWITCH 12-01-84 B TS-2-261-15D TEMPERATURE SWITCH 12-01-84 B
TS-2-261-16A TEMPERATURE SWITCH 12-01-84 B TS-2-261-16B TEMPERATURE SWITCH 12-01-84 B TS-2-261-16C TEMPERATURE SWITCH 12-01-84 B TS-2-261-16D TEMPERATURE SWITCH 12-01-84 B
TS-2-261-17A TEMPERATURE SWITCH 12-01-84 B TS-2-261-17B TEMPERATURE SWITCH 12-01-84 B
TS-2-261-l?C TEMPERATURE SWITCH 12-01-84 B TS-2-261--1 ?D TEMPERATURE SWITCH 12-01-84 B TS-2-261-18A TEMPERATURE SWITCH 12-01-84 B
TS-2-261-18B TEMPERATURE SWITCH "12-01-84 B TS-2-261-18C TEMPERATURE SWITCH 12-01-84 B TS-2-261-18D TEMPERATURE SWITCH 12-01-84 B 2-203-3B ELECTROHATIC RELIEF VALVE AND SOLENOID 12-30-83 B 2-203-3C ELECTROMATIC RELIEF VALVE AND SOLENOID 12-30-83 B 2-203-3D ELECTROHATIC RELIEF VALVE AND SOLENOID 12-30-83 B 2-203-3E ELECTROHATIC RELIEF VALVE AND SOLENOID 12-30-83 B 2-261-60A SENSOR- ACOUSTIC MONITOR 12-01-84 D 2-261-60B SENSOR- ACOUSTIC MONITOR 12-01-84 D 2-261-60C SENSOR- ACOUSTIC MONITOR 12-01-84 D 2-261-60D SENSOR- ACOUSTIC MONITOR 12-01-84 D
- 2-261-60E SENSOR- ACOUSTIC MONITOR 12-01-84 D 2-262-61A PREAMPLIFIER ACOUSTIC MONITOR 12-01-84 D 2-262-61B PREAMPLIFIER ACOUSTIC MONITOR 12-01-84 D 2-262-61C PREAMPLIFIER ACOUSTIC MONITOR 12-01-84 D 2-262-61D PREAMPLIFIER ACOUSTIC MONITOR 12-01-84 D 2-262-61E PREAMPLIFIER ACOUSTIC MONITOR 12-01-84 D
COHHONWEALTH EDISON COHPANY
LIST OF EQUIPHENT NOT PRESENTLY QUALIFIED FOR DRESDEN 2
SYSTEH: LOW PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUHBER COHPONENT
DPS-2-1501-55A DIFFERENTIAL PRESSURE SWITCH DPS-2-1501-55B DIFFERENTIAL PRESSURE SWITCH DPT-2-1543A DIFFERENTIAL PRESSURE TRANSHITTER DPT-2-1543B DIFFERENTIAL PRESSURE TRANSHITTER FS-2-1501-58A FLOW SWITCH FS-2-1501-58B FLOW SWITCH
()5-18-1983
QUALIFICATION COHPLETION DATE
12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84
PAGE 006.
REHARKS
A A A A A A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 2
SYSTEM: PRESSURE SUPPRESSION
PLANT IDENTIFICATION NUMBER COMPONENT
05-18-1983
QUALIFICATION COMPLETION DATE
PAGE 007.
REMARKS ---------------------------------------------------------------------------------------------------DPIS-2-1622A DIFFERENTIAL PRESSURE INDICATING SWITCH 12-01-84 A
DPIS-2-1622B DIFFERENTIAL PRESSURE INDICATING SWITCH 12-01-84 A
LT-2-1641-1 LEVEL TRANSMITTER 12-01-84 A
S0-2-1601-50A SOLENOID VALVE 12-01-84 A S0-2-1601-50B SOLENOID VALVE 12-01-84 A S0-2-9203A SOLENOID VALVE 12-01-84 A S0-2-9203B SOLENOID VALVE 12-01-84 A S0-2-9204A SOLENOID VALVE 12-01-84 A S0-2-9204B SOLENOID VALVE 12-01-84 A
COHHONWEALTH EDISON COHPANY
LIST OF EQUIPHENT NOT PRESENTLY QUALIFIED FOR DRESDEN 2
SYSTEM: STANDBY GAS TREATMENT
PLANT IDENTIFICATION NUHBER COHPOHENT
FSL-2/3-7541-41A FLOW SWITCH LOW FSL-2/3-7541-41B FLOW SWITCH LOW FS-2/3-7541-45A FLOW SWITCH FS-2/3-7541-45B FLOW SWITCH TSH-2/3-7541-11A TEHPERATURE SWITCH HIGH TSH~2/3-7541-11B TEHPERATURE SWITCH HIGH 2223-28A LOCAL PANEL 2223-288 LOCAL PANEL 2223-29A LOCAL PANEL 2223-29B LOCAL PANEL 2/3-7503A ELECTRIC AIR HEATER 2/3-7503B ELECTRIC AIR HEATER 2/3-7506A MOTOR EXHAUST FAN 2/3-7506B HOTOR EXHAUST FAM
05-18-1983
QUALIFICATION COHPLETIOH DATE
03-30-85 03-30-85 03-30-85 03-30-85 03-30-85 03-30-85 '()3-30-85 03-30-85 03-30-85 03-30-85 03-30-85 03-30-85 03-30-85 03-30-85
PAGE 008.
REHARKS
A A A A A A E E E E' B B A A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 2
SYSTEM: SERVICE WATER
PLANT IDENTIFICATION NUMBER COMPONENT
2-5746A 2-5746[1
REACTOR BLDG EMERGENCY AIR COOLER REACTOR BLDG EHERGENCY AIR COOLER
()5-18-1983
QUALIFICATION COMPLETION DATE
12-01-84 12-01-84
PAGE 009.
REMARKS
A A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 2
SYSTEM: CONTAINMENT ISOLATION
PLAN"T IDENTIFICATION NUMBER COMPONENT
M0-2-1001-lA MOTOR OPERATED GATE VALVE M0-2-1001-lB MOTOR OPERATED GATE VALVE S0-2-203-lA SOLENOID FOR MSIV AIR OPERATOR S0-2-203-lB SOLENOID FOR MSIV AIR OPERATOR S0-2-203-lC SOLENOID FOR MSIV AIR OPERATOR S0-2-203-lD SOLENOID FOR MSIV AIR OPERATOR S0-2-203-2A SOLENOID FOR MSIV AIR OPERATOR S0-2-203-2B SOLENOID FOR MSIV AIR OPERATOR S0-2-203-2C: SOLENOID FOR MSIV AIR OPERATOR S0-2-203-2D SOLENOID FOR MSIV AIR OPERATOR
05-18-1983
QUALIFICATION COMPLETION DATE
09-30-83 09-30-83 01-30-84 01-30-84 01-30-84 01-30-84 01-30-84 01-30-84 01-30-84 01-30-84
PAGE 010.
REMARKS
B B B B B B B B B B
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 2
SYSTEM: REACTOR RECIRCULATION
PLANT IDENTIFICATION NUMBER COMPONENT
LIS-2-263-58A LEVEL INDICATING SWITCH LIS-2-263-58B LEVEL INDICATING SWITCH LITS-2-263-73A LEVEL INDICATING TRANSMITTING SWITCH LITS-2-263-73B LEVEL INDICATING TRANSMITTING SWITCH M0-2-202-5A MOTOR OPERATED GATE VALVE & BRAKE M0-2-202-5B MOTOR OPERATED GATE VALVE & BRAKE H0-2-205-2-4 HOTOR OPERATED GATE VALVE POS-2-220-44 POSITION SWITCH POS-2-220-45 POSITION SWITCH POS-2-220-51 POSITION SWITCH POS-2-220-52 POSITION SWITCH
05-18-1983
QUALIFICATION COMPLETION DATE
12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 12-01-84 09-30-83 12-01-84 12-01-84 12-01-84 12-01-84
PAGE 011.
REMARKS
A A A A A A B A A A A
COMMONWEALTH EDISON COHPANY
LIST.OF EQUIPHENT NOT PRESENTLY QUALIFIED FOR DRESDEN 2
SYSTEH: STANDBY AC POWER
PLANT IDENTIFICATION NUMBER COMPONENT
05-18-1983
QUALIFICATION COMPLETION DATE
PAGE 012.
REMARKS ---------------------------------------------------------------------------------------------------HCC 28-1 480 V HCC 09-30-83 B
HCC 28-7 480 V HCC 09-30-83 B
HCC 29-1 480 V HCC 09-30-83 B
HCC 29-3 480 V HCC 09-30-83 B
HCC 29-4 480 V HCC 09-30-83 B HCC 29-7 480 V HCC 09-30-83 B SWGR 23-1 4.16 l<V SWITCHGEAR 09-30-83 B
SIRGR 24-1 4.16 l<V SWITCHGEAR 09-30-83 B
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 2
SYSTEM: ISOLATION CONDENSER
PLANT IDENTIFICATION NUMBER COMPONENT
05-18-1983
QUALIFICATION COMPLETION DATE
PAGE 013.
REMARKS ---------------------------------------------------------------------------------------------------M0-2-1301-1 M0-2-1301-4
MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE
09-30-83 09-30-83
B B
e
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 2
SYSTEM: GENERAL USE ELECTRICAL EQUIPMENT
PLANT IDENTIFICATION NUMBER COMPONENT QUALIFICATION COMPLETION DATE
CABLE ANHYDREX XX PLASTEX INSU & JKT 12-30-84 CABLE ANHYDREX XX PLASTEX INSU & JKT 12-30-84 CABLE BUTYL RBR INSU POLYVN CHLORIDE JKT 12-30-84 CABLE BUTYL RBR INSU POLYVN CHLORIDE JKT 12-30-84 CABLE BUTYL RBR INSU POLYVN CHLORIDE JKT 12-30-84 CABLE CROSSLINKED POLYFIN W-16 AWG DRN & JKT 12-30-84 CABLE CSPE INSUL., POLYESTER ALUMINUM SHLD. AND 12-30-84 CABLE EPDM I INSUL. W/HAPALON COND. JKT AND OVE 12-30-84 CABLE EPDM I INSUL. W/HAPALON COND. JKT AND OVE 12-30-84 CABLE EPDM II INSUL. W/HAPALON COND. JKT. AND 0 12-30-84 CABLE EPDM INSUL. W/HAPALON JKT DRN. AND SHLD. 12-30-84 CABLE EPR INSUL. COPPER DRAIN WIRES CHLORINATED 12-30-84 CABLE EPR INSUL. CSPE JKT. 12-30-84 CABLE EPR W/CSPE JKT., FR SHLD, DRN WIRE AND OV 12-30-84 CABLE EPR W/CSPE JKT., FR SHLD, DRN WIRE AND OV 12-30-84 CABLE EPR W/NEOPRENE INSUL. AND JKT. 12-30-84 CABLE FR-EPDM AND 16 AWG AND HYPALON JKT. 12-30-84 CABLE HULT! PAIR WITH OVERALL SH CU-CON 12-30-84 CABLE OKONITE EPR INSUL. WITH OKO COVER AND OVE 12-30-84 CABLE POLY NYLON INSU SHLD & PLASTEX INSTR 12-30-84 CABLE POLYETH INSU POLYV CHLORIDE JKT 12-30-84 CABLE RBR INSU POLYV CHLORIDE JACKET 12-30-84 CABLE SINGLE/MULTIPAIR CABLE WITH OVERALL SH 12-30-84 CABLE SR IHSUL. WITH GLASSBRAID AND SIL. SAT. A 12-30-84 CABLE SWITCHBOARD-TYPE SIS tSI 57275 VULKENE 12-30-84 CABLE XLPE INSUL. WITH NEOPRENE JKT. 12-30-84 CABLE 3 TW WITH OVERALL SH 12-30-84 CABLE <SHIELDED> EPR INSUL. EXTRUDED SEMI. COND. CSPE INSU 12-30-84 79-01B-14 TERMINAL BLOCK 12-01-84 79-01B-15 TERMINAL BLOCK 12-01-84 79-01B-16 TERMINAL BLOCK 12-01-84 7?-0iB-17 TERMINAL BLOCK 12-01-84 79-01B-1H TERMINAL ItLOr.K 12-01-1:14 79-01B-19 TERMINAL BLOCK 12-01-1:14 79-01B-20 TERMINAL BLOCK 12-01-84 79-01B-21 TERMINAL BLOCK 12-01-84
PAGE 014.
REMARKS
B B B B B B B B B B B B B B B B B B B B B B B B B B B B A A A A A A A A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 2
SYSTEM: CAM
PLANT IDENTIFICATION NUMBER COMPONENT
HS-2-2402-A HYDROGEN SENSOR HS-2-2402-B HYDROGEN SENSOR HS-2-2402-C HYDROGEN SENSOR HS-2-2402-D HYDROGEN SENSOR PT-2-2421-A PRESSURE TRANSMITTER PT-2-2421-B PRESSURE TRANSMITTER RE-2-2418-A l~ADIATION DETECTOR RE-2-2418-B RADIATION DETECTOR S0-2-2499-3A SOLENOID VALVE S0-2-2499-3B SOLENOID VALVE S0-2-249'1-4A SOLENOID VALVE S0-2-2499-4B SOLENOID VALVE
'
05-18-1983
QUALIFICATION COMPLETION DATE
01-01-84 01-01-84 01-01-84 01-01-84 06-30-84 06-30-84 01-01-84 01-01-84 12-01-84 12-01-84 12-01-84 12-01-84
PAGE 015.
REMARKS
D ii D D B B D D c c c c
COHMONWEALTH EDISON COMPANY
DRESDEN UNIT 3
LIST OF EQUIPHENT NOT PRESENTLY QUALIFIED
DATE OF ISSUE 05-18-1983
THE FOLLOWING REMARKS APPLY TO THIS LIST-
A. COHPONENT REPLACEMENT
B. COMPONENT ENGINEERING ANALYSIS AND/OR TESTING OR EVALUATION
C. ADDITIONAL VENDOR INFORHATION REQUIRED FOR COHPONENT QUALIFICATION
D. CECO COHHITTHENT TO INSTALL QUALIFIED COHPONENT
E. RELOCATION AND/OR SHIEDLING OF COHPONENT <NO QUALIFIED COMPONENT AVAILABLE IN THE HARKET FOR THE REQUIRED RADIATION DOSE>
PAGE 001.
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 3
SYSTEM: REACTOR PROTECTION
PLANT IDENTIFICATION NUMBER COMPONENT
TE-3-1291-60A TEMPERATURE ELEMENT TE-3-1291-60B TEMPERATURE ELEMENT TE-3-1291-60C TEMPERATURE ELEMENT TE-3-1291-60D TEMPERATURE ELEMENT TE-3-1291-60E TEMPERATURE ELEMENT TE-3-1291-60F TEMPERATURE ELEMENT TE-3-1291-60G TEMPERATURE ELEHENT TE-3-1291-60H TEMPERATURE ELEMENT
\
05-18-1983
QUALIFICATION COMPLETION DATE
05-30-85 05-30-85 05-30-85 05-30-85 05-30-85 05-30-85 05-30-85 05-30-85
PAGE 002.
REMARKS
A A A A A A A A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 3
SYSTEM: CORE SPRAY
PLANT IDENTIFICATION NUMBER COMPONENT
FS-3-1464A FS-3-1464B M0-3-1402-38A M0-3-1402-38Et
/
FLOW SWITCH FLOW SWITCH MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE
05-18-1983
QUALIFICATION COMPLETION DATE
05-30-85 05-30-85 05-30-85 05-30-85
-PAGE 003.
REMARKS
A A A A
- COMMONWEALTH EDISON COMPANY 05-18-1983 PAGE 004.
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 3
SYSTEM: HIGH PRESSURE COOLANT INJECTION ---------------------------------------------
QUALIFICATION PLANT IDENTIFICATION NUMBER COMPONENT COMPLETION DATE REMARKS ---------------------------------------------------------------------------------------------------DPIS-3-2352 DIFFERENTIAL PRESSURE INDICATING SWITCH 05-30-85 A DPIS-3-2353 DIFFERENTIAL PRESSURE INDICATING SWITCH 05-30-85 A H0-3-2301-36 MOTOR OPERATED GATE VALVE 05-30-85 A H0-3-2301-4 MOTOR OPERATED GATE VALVE 05-30-85 A M0-3-2301-5 MOTOR OPERATED GATE VALVE 09-30-83 B M0-3-2301-8 MOTOR OPERATED GATE VALVE 09-30-83 B PS-3-2389A PRESSURE SWITCH 05-30-85 A PS-3-2389B PRESSURE SWITCH 05-30-85 A PS-3-2389C PRESSURE SWITCH 05-30-85 A PS-3-2389D PRESSURE SWITCH 05-30-85 A TS-3-2370A TEMPERATURE SWITCH 05-30-85 A TS-3-2370B TEMPERATURE SWITCH 05-30-85 A !
TS-3-2370C TEMPERATURE SWITCH 05-30-85 A TS-3-2370D TEMPERATURE SWITCH 05-30-85 A TS-3-2371A TEMPERATURE SWITCH 05-30-85 A TS-3-2371B TEMPERATURE SWITCH 05-30-85 A TS-3-2371C TEMPERATURE SWITCH 05-30-85 A TS-3-2371D TEMPERATURE SWITCH 05-30-85 A TS-3-<?372A TEMPERATURE SWITCH 05-30-85 A TS-3-2372B 11:.HPERATURE 9WITCI I 05-30-85 A TS-3-2372C TEMPERATURE SWITCH 05-30-85 A TS-3-2372D TEMPERATURE SWITCH 05-30-85 A TS-3-2373A TEMPERATURE SWITCH 05-30-85 A TS-3-2373B TEMPERATURE SWITCH 05-30-85 A
e TS-3-2373C TEHP8~ATURE SWITCH 05-30-85 A TS-3-2373D TEMPERATURE SWITCH 05-30-85 A
/
e
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 3
SYSTEM: AUTO DEPRESSURIZATION/ HAIN STEAM
PLANT IDENTIFICATION NUMBER COMPONENT
05-18-1983
QUALIFICATION COMPLETION DATE
PAGE 005.
REHARl<S ---------------------------------------------------------------------------------------------------TS-3-261-15A TEMPERATURE SWITCH 05-30-85 B TS-3-261-15B TEMPERATURE SWITCH 05-30-85 B TS-3-261-15C TEMPERATURE SWITCH 05-30-85 B TS-3-261-15D TEMPERATURE SWITCH 05-30-85 B TS-3-261-16A TEMPERATURE SWITCH 05-30-85 B TS-3-261-16B TEMPERATURE SWITCH 05-30-85 B TS-3-261-16C TEMPERATURE SWITCH 05-30-85 B TS-3-261-160 TEMPERATURE SWITCH 05-30-85 B TS-3-261-17A TEMPERATURE SWITCH 05-30-85 B TS-3-261-17B TEMPERATURE SWITCH 05-30-85 B TS-3-261-17C TEMPERATURE SWITCH 05-30-85 B TS-3-261-170 TEMPERATURE SWITCH 05-30-85 B TS-3-261-lBA TEMPERATURE SWITCH 05-30-85 B TS-3-261-188 TEMPERATURE SWITCH 05-30-85 B TS-3-261-18C TEMPERATURE SWITCH 05-30-85 B TS-3-261-18D TEMPERATURE SWITCH 05-30-85 B 3-203-3B ELECTROHATIC RELIEF VALVE AND SOLENOID 12-30-83 B 3-?0::l-3C ELE~TROMATIC RELIEF VALVE AND SOLENOTD 12-30-83 B 3-203-3D ELECTRUl'\AIIC RELIEF VALVC AND SOLENOID 12-30-83 B 3-203-3E ELECTROMATIC RELIEF VALVE AND SOLENOID 12-30-83 B 3-261-60A SENSOR-ACOUSTIC MONITOR 05-30-85 A 3-261-60B SENSOR-ACOUSTIC MONITOR
_, 05-30-85 A
3-261-60C SENSOR-ACOUSTIC MONITOR 05-30-85 A 3-261-600 SENSOR-ACOUSTIC MONITOR 05-30-85 A 3-261-60E SENSOR-ACOUSTIC MONITOR 05-30-85 A 3-262-61A PREAMPLIFIER ACOUSTIC MONITOR 05-30-85 A 3-262-61B PREAMPLIFIER ACOUSTIC MONITOR 05-30-85 A 3-262-61C PREAMPLIFIER ACOUSTIC MONITOR 05-30-85 A 3-262-61D PREAMPLIFIER ACOUSTIC MONITOR 05-30-85 A 3-262-61E PREAMPLIFIER ACOUSTIC MONITOR 05-30-85 A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 3
SYSTEM: LOW PRESSURE COOLANT INJECTION
PLANT IDENTIFICATION NUHBER COMPONENT
DPS-3-1501-55A DIFFERENTIAL PRESSURE SWITCH DPS-3-1501-55[1 DIFFERENTIAL PRESSURE SWITCH FS-3-1501-58A FLOW SWITCH FS-3-1501-58B FLOW SWITCH H0-3-1501-3A MOTOR OPERATED GLOBE VALVE & BRAKE H0-3-1501-3B HOTOR OPERATED GLOBE VALVE & BRAKE
05-18-1983
QUALIFICATION COMPLETION DATE
05-30-85 05-30-85 05-30-85 05-30-85 05-30-85 05-30-85
PAGE 006.
REMARKS
A A A A A A
COHHONWEALTH EDISON COHPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 3
SYSTEM: PRESSURE SUPPRESSION
PLANT IDENTIFICATION NUMBER COMPONENT
DPIS-3-1622A DIFFERENTIAL PRESSURE INDICATING SWITCH DPIS-3-1622B DIFFERENTIAL PRESSURE INDICATING SWITCH LT-3-1641-1 LEVEL TRANSMITTER S0-3-1601-50A SOLENOID VALVE S0-3-1601-SOB SOLENOID VALVE S0-3-9203A SOLENOID VALVE S0-3-9203B SOLENOID VALVE S0-3-9204A SOLENOID VALVE S0-3-9204B SOLENOID VALVE
05-18-1983
QUALIFICATION COMPLETION DATE
05-30-85 05-30-85 05-30-85 05-30-85 05-30-85 05-30-85 05-30-85 05-30-85 05-30-85
PAGE 007.
RE HARKS
A A A A A A A A A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 3
SYSTEM: SERVICE WATER
PLANT IDENTIFICATION NUMBER COMPONENT
3-5746A 3-5746[1
REACTOR BLDG EMERGENCY AIR COOLER REACTOR BLDG EMERGENCY AIR COOLER
05-18-1983
QUALIFICATION COMPLETION DATE
05-30-85 05-30-85
PAGE 008.
REMARKS
A A
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 3
SYSTEM: CONTAINMENT ISOLATION
PLANT IDENTIFICATION NUMBER COMPONENT
M0-3-1001-lA MOTOR OPERATED GATE VALVE H0-3-1001-18 HOTOR OPERATED GATE VALVE M0-3-1201-2 MOTOR OPERATED GATE VALVE H0-3-1201-3 MOTOR OPERATED GATE VALVE H0-3-220-1 MOTOR OPERATED GLOBE VALVE H0-3-3706 MOTOR OPERATED GATE VALVE S0-3-203-lA SOLENOID FOR HSIV AIR OPERATOR S0-3-203-lB SOLENOID FOR HSIV AIR OPERATOR S0-3-203-lC SOLENOID FOR MSIV AIR OPERATOR S0-3-203-1D SOLENOID FOR HSIV AIR OPERATOR S0-3-203-2A SOLENOID FOR MSIV AIR OPERATOR S0-3-203-28 SOLENOID FOR MSIV AIR OPERATOR S0-3-203-2C SOLENOID FOR HSIV AIR OPERATOR S0-3-203-2D SOLENOID FOR HSIV AIR OPERATOR
05-18-1983
QUALIFICATION COMPLETION DATE
05-30-85 05-30-85 05-30-85 05-30-85 05-30-85 05-30-85 01-30-84 01-30-84 01-30-84 01-30-84 01-30-84 01-30-84 01-30-84 01-30-84
PAGE 009.
REMARKS
A A A A A A B B B B B B B B
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 3
SYSTEM: REACTOR RECIRCULATION
PLANT IDENTIFICATION NUMBER COMPONENT
LIS-3-263-58A LEVEL INDICATING SWITCH LIS-3-263-580 LEVEL INDICATING SWITCH LITS-3-263-73A LEVEL INDICATING TRANSMITTING SWITCH LITS-3-263-73B LEVEL INDICATING TRANSMITTING SWITCH M0-3-202-5A MOTOR OPERATED GATE VALVE & BRAKE M0-3-202-50 MOTOR OPERATED GATE VALVE & BRAKE H0-3-202-7A MOTOR OPERATED GATE VALVE M0-3-202-7B MOTOR OPERATED GATE VALVE M0-3-205-2-4 MOTOR OPERATED GATE VALVE POS-3-220-44 POSITION SWITCH POS-3-220-45 POSITION SWITCH POS-3-220-51 POSITION SWITCH POS-3-220-52 POSITION SWITCH
05-18-1983
QUALIFICATION COMPLETION DATE
05-30-85 05-30-85 05-30-85 05-30-85 05-30-85 05-30-85 09-30-83 09-30-83 09-30-83 05-30-85 05-30-85 05-30-85 05-30-85
PAGE 010.
REMARKS
A A A A A A B B B A A A A
COHHONWEALTH EDISON COHPANY
LIST OF EQUIPHENT NOT PRESENTLY QUALIFIED FOR DRESDEN 3
SYSTEM: STANDBY AC POWER
PLANT IDENTIFICATION NUHBER COHPONENT
HCC 38-1 480 V HCC HCC 38-2 480 V HCC HCC 38-3 480 V HCC MCC 38-4 480 V HCC MCC 38-7 480 V HCC HCC 39-1 480 V HCC HCC 39-2 480 V HCC HCC 39-3 480 V HCC HCC 39-7 480 V HCC SWGR 33-1 4.16 KV SWITCHGEAR SWGR 34-1 4.16 KV SWITCHGEAR
05-18-1983
QUALIFICATION COHPLETION DATE
09-30-83 09-30-83 09-30-83 09-30-83 09-30-83 09-30-83 09-30-83 09-30-83 09-30-83 09-30-83 09-30-83
PAGE 011.
RE HARKS
B B B B B B B B B B B
COMMONWEALTH EDISON COMPANY
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 3
SYSTEM: ISOLATION CONDENSER
PLANT IDENTIFICATION NUMBER COMPONENT
H0-3-1301-1 110-3-1301'-4
MOTOR OPERATED GATE VALVE MOTOR OPERATED GATE VALVE
05-18-1983
QUALIFICATION COMPLETION DATE
09-30-83 09-30-83
PAGE 012.
REMARKS
B B
e
COMMONWEALTH EDISON COMPANY 05-18-1983
LIST OF EQUIPMENT NOT PRESENTLY QUALIFIED FOR DRESDEN 3
SYSTEM: GENERAL USE ELECTRICAL EQUIPMENT
PLANT IDENTIFICATION HUMBER COMPONENT QUALIFICATION COMPLETION DATE
CABLE AHHYDREX XX PLASTEX INSU & JKT 05-30-85 CABLE ANHYDREX XX PLASTEX INSU & JKT 05-30-85 CABLE BUTYL RBR INSU POLYVN CHLORIDE JKT 05-30-85 CABLE BUTYL RBR INSU POLYVN CHLORIDE JKT 05-30-85 CABLE BUTYL RBR INSU POLYVN CHLORIDE JKT 05-30-85 CABLE CROSSLINKED POLYFIN W-16 AWG DRH & JKT 05-30-85 CABLE CSPE INSUL., POLYESTER ALUMINUM SHLD. AND 05-30-85 CABLE EPDM I INSUL. W/HAPALON COND. JKT AND OVE 05-30-85 CABLE EPDH I INSUL. W/HAPALON COND. JKT AND OVE 05-30-85 CABLE EPDM II IHSUL. W/HAPALOH COND. JKT. AND 0 05-30-85 CABLE EPDH INSUL. W/HAPALON JKT DRN. AND SHLD. 05-30-85 CABLE EPR INSUL. CSPE JKT. 05-30-85 CABLE EPR W/CSPE JKT., FR SHLD, DRN WIRE AND OV 05-30-85 CABLE EPR W/CSPE JKT., FR SHLD, DRH WIRE AND OV 05-30-85 CABLE EPR W/HEOPRENE INSUL. AND JKT. 05-30-85 CABLE FR-EPDM AND 16 AWG AND HYPALON JKT. 05-30-85 CABLE HUI.TI PAIR WITH OVERALL SH CU CON 05-30-85 CABLE OKOHITE EPR INSUL. WITH OKO COVER AND OVE 05-30-85 CABLE POLY NYl.ON !HSU SHLD & PLASTEX INSTR 05-30-85 CABLE POLYETH INSU POLYV CHLU~IDE JKT 05-30-85 CABLE RBR INSU POLYV CHLORIDE JACKET 05-30-85 CABLE SINGLE/HULTIPAIR CABLE WITH OVERALL SH 05-30-85 CABLE SR INSUL. WITH GLASSBRAID AND SIL. SAT. A 05-30-85 CABLE SWITCHBOARD-TYPE SIS tSI 57275 VULKENE 05-30-85 CABLE XLPE INSUL. WITH NEOPRENE JKT. 05-30-85 CABLE 3 TW WITH OVERALL SH 05-30-85 CABLE <SHIELDED> EPR INSUL. COPPER DRN WIRES CHLORINATED P 05-30-85 CABLE <SHIELDED> EPR INSUL. EXTRUDED SEMI COND. CSPE IHSUL 05-30-85 79-0lB-14 TERMINAL BLOCK 05-30-85 79-0lB-15 TERMINAL BLOCK 05-30-85 79-018-16 TERMINAL BLOCK 05-30-85 79-01B-17 TERMINAL BLOCK 05-30-85 79-018-18 TERHINAL l!LOCK 05-30-AS 79-018-19 TERMlNAL BLOCK 05-30-85 79-01B-20 TERMINAL BLOCK 05-30-85 79-01B-21 TERMINAL BLOCK 05-30-85
PAGE 013.
RE HARKS
B B B B B B B B B B B B B B B B B B B D B B B B B B B B A A A A A A A A
COHHONWEALTH EDISON COHPANY
LIST OF EQUIPHENT NOT PRESENTLY QUALIFIED FOR DRESDEN 3
SYSTEH: CAM
PLANT IDENTIFICATION NUHBER COHPONENT
HS-3-2402-A HYDROGEN SENSOR HS-3-2402-B HYDROGEN SENSOR HS-3-2402-C HYDROGEN SENSOR HS-3-2402-D HYDROGEN SENSOR PT-3-2421-A PRESSURE TRANSHITTER PT-3-2421-8 PRESSURE TRANSHITTER S0-3-2499-3A SOLENOID VALVE S0-3-2499-38 SOLENOID VALVE S0-3-2499-4A SOLENOID VALVE S0-3-2499-48 SOLENOID VALVE
•
05-18-1983
QUALIFICATION COHPLETION DATE
01-01-84 01-01-84 01-01-84 01-01-84 05-30-85 05-30-85 05-30-85 05-30-85 05-30-85 05-30-85
PAGE 014.
RE HARKS
D D ])
D B B B 8 B B