Statement of Environmental Effects

15
Statement of Environmental Effects No. 52 Drummond Rd Oyster Bay NSW 2225 Page 1 of 10 Statement of Environmental Effects Proposal: Proposed alterations and additions to existing dwelling and new pool Address: Lot 376 DP 14716, No. 52 Drummond Rd Oyster Bay NSW 2225 Prepared by: Paperseed Design Version/Date: Revision 01, 10 September 2018 Applicant: Grace Leung, Paperseed Design

Transcript of Statement of Environmental Effects

 Statement of Environmental Effects    

No. 52 Drummond Rd Oyster Bay NSW 2225 Page 1 of 10 

 

 

 

 

Statement of Environmental Effects  

 Proposal:  Proposed alterations and additions to existing 

dwelling and new pool  Address:   Lot 376 DP 14716, No. 52 Drummond Rd Oyster Bay 

NSW 2225 

Prepared by:  Paperseed Design   

Version/Date:     Revision 01, 10 September 2018 

Applicant:     Grace Leung, Paperseed Design 

 Statement of Environmental Effects    

No. 52 Drummond Rd Oyster Bay NSW 2225 Page 2 of 10 

Contents1 Introduction ......................................................................................................................................... 3 

2 Site suitability ....................................................................................................................................... 4 

3 Present and previous uses of the land ................................................................................................. 4 

4 Compliance with development standards ........................................................................................... 5 

5 Access and traffic ................................................................................................................................. 5 

6 Privacy, views and overshadowing ...................................................................................................... 5 

7 Drainage ............................................................................................................................................... 7 

8 Erosion and sediment control .............................................................................................................. 7 

9 Energy efficiency .................................................................................................................................. 7 

10 Site management ............................................................................................................................... 8 

11 Finishes Schedule ............................................................................................................................... 8 

12 Variation Justification Statement ....................................................................................................... 8 

13 Conclusion ........................................................................................................................................ 10 

14 Appendix .......................................................................................................................................... 10 

 

 

 

 Statement of Environmental Effects    

No. 52 Drummond Rd Oyster Bay NSW 2225 Page 3 of 10 

1IntroductionThe proposal consists of the following works at Lot 376 DP 14716, No. 52 Drummond Rd Oyster Bay 

NSW 2225 

Proposed alterations and additions to existing dwelling and new pool 

The statement accompanies plans prepared by: 

Architectural Plans by:   Paperseed Design 

Basix Plans by:     Paperseed Design 

In this document, the scheme is presented and appraised having regard to the relevant planning 

controls of Sutherland Shire Development Control Plan 2015 and Sutherland Shire LEP 2015.  

 

 

 

 

 Statement of Environmental Effects    

No. 52 Drummond Rd Oyster Bay NSW 2225 Page 4 of 10 

2SitesuitabilityThe subject site is located at No. 52 Drummond Rd Oyster Bay NSW 2225. The site is 659m2 in size, 

single frontage rectangular block, with frontage to Drummond Road facing North. The site steeply 

slopes from the North side of the property to the South side of the property. The site is located 

700m walking distance to a Bus Stop and 1.2km distance to Como Station. 

The site is zoned ‘R2’, which permits dwelling houses in the LEP requirements. Adjoining 

development surrounding the property include a mixture of single and two storey dwellings, varying 

in age and styles.  

The proposed property meets the local planning objectives being compatible with the established 

character and streetscape. The proposed property is of a scale and density that is compatible with 

the predominantly single dwelling character of the locality. 

 

 

Figure 1 ‐ Location of house 

3PresentandprevioususesofthelandThe present use of the site is a single storey weatherboard clad dwelling. The present uses of 

adjoining land are residential dwellings. 

There are no potentially contaminating activity on the property or nearby the property that we are 

aware of. No testing of the site for land contamination has been done. 

 Statement of Environmental Effects    

No. 52 Drummond Rd Oyster Bay NSW 2225 Page 5 of 10 

4CompliancewithdevelopmentstandardsThe following planning instruments impact on the proposed development: 

The Sutherland Shire Development Control Plan 2015 

The Sutherland Shire Local Environment Plan 2015 

The proposed development complies with the requirements of each code that is set out by 

Sutherland Shire Council. Refer to the compliance table below: 

Site Area  659m2  

FSR 0.55:1   231m2 0.35:1 (COMPLIES) 

Height 8.5m2  8.5m (COMPLIES) 

Landscape area 35%   272m2 41.2% (COMPLIES) 

Native Trees (4 minimum)  3 existing native trees at front setback, 2 new native trees planted at rear 

5AccessandtrafficThe proposal includes 2 car lock up garage parking for its residence. Vehicle access is proposed via 

Drummond Road 

The site is located 700m walking distance to a Bus Stop and 1.2km distance to Como Station. 

6Privacy,viewsandovershadowingVisualPrivacyWindows placed relative to adjacent dwellings and common areas have been designed to prevent 

overlooking by minimizing side windows and facing windows to the front and rear.  

There are no views between living rooms and the private yards of other dwellings. The outlook from 

the balcony to the rear neighbour is obscured by trees, hence there is no overlooking into rear 

neighbours. Refer to Figure 2. 

The pool cannot be seen from the street as the site slopes steeply from the street to the rear. The 

view from the street to the front of the house is also obscured by trees. Refer to Figure 4. 

 Statement of Environmental Effects    

No. 52 Drummond Rd Oyster Bay NSW 2225 Page 6 of 10 

 

 

 

 

 

Figure 2 – View to rear neighbour – showing privacy of trees obscuring view 

AcousticPrivacyBedrooms have been separated from outdoor areas and parking areas, where they are placed on the 

second storey. 

Living rooms have been directed to face the rear yard, away from adjoining properties. 

The external air‐conditioning unit and swimming pool pump equipment will be acoustically screened 

to ensure equipment will not exceed an LAeq (15min) of 5dB (A) above background noise at the 

property boundary.  

ViewsNo view will be affected by the proposed development. 

OvershadowingThe proposed development has been orientated to maximise natural light penetration to indoor 

areas, with northern windows that allow penetrate to the rear living areas.  

The rumpus room in the proposed development has 9 hours of direct sunlight between 9am and 

3pm in midwinter.  

The private open space at the rear South has at least 3 hours of direct sunlight at 9am and 3pm. 

Additionally, the private open space at the North corner has 3 hours of direct sunlight between 9am 

and 12am. These private open areas equate over 10m2 of area that has 3 hours of direct sunlight. 

Neighbouring dwellings have not been affected by the proposed development, allowing minimum 3 

hours of solar access to living and private open spaces, between 9am and 3pm during midwinter. 

 Statement of Environmental Effects    

No. 52 Drummond Rd Oyster Bay NSW 2225 Page 7 of 10 

7DrainageRefer to stormwater engineer’s drawings. 

8ErosionandsedimentcontrolThe proposed development takes into consideration prevention of erosion and control sediment on 

the site, with use of: 

Sediment barrier fencing 

Kerb inlet sediment traps  

Stabilized access across driveway 

Covering of stockpile storage and building materials 

Refer to Erosion and Sediment Control Plan 

9EnergyefficiencyThe proposed development has been orientated to maximise living areas to face the north, with the 

rumpus room facing north. 

A combination of setback of balconies, shading and blinds have been provided to the windows to 

maximise summer shade and minimise winter shade. 

Insulation proposed for the development meets the requirements for Basix. 

Windows have good natural cross ventilation. 

All heating, cooling and lighting systems meet the requirements for Basix. 

The clothes drying space is located at the South with solar access from 12am‐3pm. 

 

 Statement of Environmental Effects    

No. 52 Drummond Rd Oyster Bay NSW 2225 Page 8 of 10 

10SitemanagementThe proposed development takes into consideration the site management to ensure public safety 

and minimise public inconvenience: 

Perimeter fencing to restrict public access to the construction site. Storage of building materials and equipment, bin containers and material stockpiles located at 

the flat area of the site. Any loose materials will be covered. Signs will be placed at the front fence to direct pedestrians for site contacts prior to entry. The access point for vehicles will be via the existing driveway. Refer to Erosion and Sediment Control Plan. 

11FinishesScheduleLocation  Material 

Basement & Ground Floor External Walls  Lightweight ‘Harditex’ rendered cladding in Quarter Lexicon – James Hardie 

First Floor External Walls  ‘Snaplock’ Metal cladding in ‘Monument’ 

Windows & Louvers  Aluminium powdercoated in ‘black’ and ‘natural white’ 

Roofing  ‘Snaplock’ Metal cladding in ‘Monument’ 

 

Refer to product specifications in the Appendix. 

12VariationJustificationStatementThe proposal does not meet the numerical controls for the garage setbacks, which requires the 

garage to be setback 1m behind the building line. The proposed setback for the garage is zero 

setback on the front boundary. The justification for the zero setback is due to the pre‐existing 

location of the house and the steep slope of the site. The characteristics of the streetscape show 

that garages are located on the front boundary, hence the zero setback would be justified. See 

Figure 3. 

The proposal does not meet the numerical controls for the setbacks for the site, which require 

maximum 60% depth being 28.41m. The proposed depth of the dwelling is 33.162m. The 

justification for the non‐compliance is due to the pre‐existing location of the site being significantly 

set back towards the rear of the property. The noncompliance does not affect any amenities to the 

neighbours, where there are no issues with overlooking into the rear with trees obscuring views and 

there is minimal impact on overshadowing. Refer to Figure 2.  

Additionally, the proposal does not meet the numerical controls for the deep soil landscaping 

requirements at the front of the building line, which require 50% deep soil landscaping within the 

street frontage, being 101m2. The proposed deep soil landscaping within the street frontage is 

87m2. The justification for the noncompliance is due to the pre‐existing location of the existing 

dwelling being significantly set back towards the rear of the property. Being setback significantly 

means that there would be significantly more deep soil landscaping that the DCP standard. There is 

 Statement of Environmental Effects    

No. 52 Drummond Rd Oyster Bay NSW 2225 Page 9 of 10 

also more overall deep soil landscaping than the minimum DCP requirements of 35%, with the 

proposal providing 41.2% of overall deep soil landscaping. Moreover, with the set location of the 

garage, this also affects the deep soil requirement, hence the noncompliance would be justified. 

Refer to Figure 4 showing landscaping at front setback. 

    

Figure 3 – Garage and carport on front boundary line along Drummond Road 

 Statement of Environmental Effects    

No. 52 Drummond Rd Oyster Bay NSW 2225Page 10 of 10 

 

Figure 4 – View to front of house showing steep slope to rear & landscaping at front setback 

13ConclusionIn conclusion, the proposal compliant and consistent with the relevant controls: 

Compliments the existing streetscape of the area 

Complies with the development standards 

Complies with traffic and access requirements 

Complies with Privacy, Acoustic and overshadowing 

Complies with energy requirements 

Complies with sediment and erosion control requirements 

The proposal is consistent with complying with the Sutherland Shire Control Plan 2015 and therefore 

recommended that Council give supportive consideration to the proposed development application. 

14AppendixProduct specifications attached. 

 

22

CLA

DD

ING

James Hardie Product Catalogue

HardieTex™ systemHardieTex™ system is a strong, pre-primed base

sheet that is finished on-site with a specialised

texture coat system*, which includes joint

reinforcement. HardieTex™ system is the original

way to create a decorative, monolithic rendered

look without the need for masonry.

HardieTex™ system is suitable for use as

an external cladding in residential homes,

including alterations and additions, where a

lightweight system with a monolithic rendered

look is required. Ideal for full wrap or composite

construction designs on either timber or light

gauge steel framed homes.

HardieTex™

sheet

Product Code

Length (mm)

Width (mm)

Thickness (mm)

Mass (kg/m2)

Coverage per Panel (m2)

400293 2,440 900 7.5 11.33 2.20

401651 2,440 1,200 7.5 11.33 2.93

400295 2,725 900 7.5 11.33 2.45

400294 2,725 1,200 7.5 11.33 3.27

400296 3,000 900 7.5 11.33 2.70

400291 3,000 1,200 7.5 11.33 3.60

Selling units per pack: 30 sheets or each

23

CLA

DD

ING

James Hardie Product Catalogue

James Hardie™ 7.5mm PVC Starter StripA perforated PVC extrusion, used with HardieTex™ base sheet to provide a straight edge to finish the texture coating or used with PrimeLine™ Newport or Summit weatherboard to kick out the bottom row to the correct angle.Length: 3,000mmSelling Unit: 25 per pack

HardieTex™ 7.5mm PVC Z FlashingA PVC extrusion for use with HardieTex™ system to provide an alternative detail option at horizontal control joints.Length: 3,000mmSelling Unit: 25 per pack

305568 305569

HardieDrive™ Screws 32mm long A class 3 finish self-tapping wing-tipped screw for fastening to 0.8mm to 1.6mm BMT steel frames.Selling Unit: 500 per box

HardieDrive™ Screws 40mm long A class 3 finish self-tapping wing-tipped screw for fastening to 0.8mm to 1.6mm BMT steel frames.Selling Unit: 500 per box

305532 305533

James Hardie™ Fibreshears Electric tool for cutting fibre cement sheets.Selling Unit: 1 each

Villaboard™ Knife A score and snap knife designed to efficiently cut through James Hardie™ external cladding and internal lining products ≤9mm thick. Selling Unit: 12 per pack

300653 305915

HardieBlade™ Saw Blade 185mm A poly-diamond blade for fast and clean cutting of James Hardie™ fibre cement.Diameter: 185mmSelling Unit: 1 each

HardieBlade™ Saw Blade 254mm A poly-diamond blade for fast and clean cutting of James Hardie™ fibre cement.Diameter: 254mmSelling Unit: 1 each

300660 303375

James Hardie™ Joint Sealant^ 300mL cartridge A general purpose, paintable, exterior grade polyurethane joint sealant.300mL cartridgeSelling Unit: 20 per box

James Hardie™ Joint Sealant^ 600mL sausage A general purpose, paintable, exterior grade polyurethane joint sealant.600mL sausageSelling Unit: 20 per box

305534 305672

Accessories & Tools Supplied by James Hardie

Notes: All dimensions and masses provided are approximate only and subject to manufacturing tolerances. Masses are based on equilibrium content of product. Products are to be installed in accordance with the relevant and current Product Installation Guide and Technical Documentation. For information relating to installation, best practices, warnings and warranties visit www.jameshardie.com.au or phone us on 13 11 03. Refer to the relevant and current Product Installation Guide for accessories and/or tools not supplied by James Hardie.

Key: * Not supplied by James Hardie. To be applied in accordance with the texture coat manufacturer’s guidelines. ^ Not to be used in fire applications.

54

Altra Shutters | Interior | ExteriorDurable | Lockable | Sliding | Folding | Hinged | Fixed | Increased View

1 Altra Sliding Shutters. Wide Louvers, minimum frame, maximum view. 2 Altra Hinged shutters 3 Altra Exterior Multi-fold and fixed panels above, custom colour 4 Altra Fixed panels raked at top 5 and 6 Altra Exterior Multi-fold and fixed panels below, custom colour 7 Altra wall mount fixed U Chanel 100mm angle 8 Multi-fold with Flush Bolt. and recessed P94 track 9 Flush Bolt. 10 Key Lock Double Shoot Bolt 11 BRS (Bottom Roll Sliding) Tracks 12 Altra P94 Bottom track for top hang sliding and Bi-fold shutters 13 Recessed P94 track.

Options: Flush Bolts | Key Locks | Colours: Silver Anodised, Standard Powder Coat or Custom Colours.

3

1 Maximise the view with Sliding Altra 2 Altra Multifold hinged

Multifold Altra 4 Raked top - Altra Fixed U Channels 7 Altra fixed panel with 100mm angle 8 Altra Multifold

5 Altra Multifold and fixed panel 6 Altra Multifold and fixed panel

9 10 12 1311

Snaplock:: Modern take on traditional systems :: Suitable for roof and wall cladding :: Multiple laying pattern options :: Concealed fixing with no joint crimping :: Contemporary, linear aesthetic

Overview

Snaplock is ideal for modern architectural developments. Providing a similar

aesthetic to Standing Seam, Snaplock doesn’t require seam closing tools, as the profile is designed to “snap”

together.

Product Specs:: 25 mm or 38 mm rib heights (from base to rib top)

:: 165 mm to 500 mm pan widths, rib to rib (material dependant)

:: Up to 9000 mm long panels (material dependant)

:: Concealed fixing with countersunk screws and approved clips

:: Panels can be laid horizontally, vertically and diagonally

:: Custom curved systems available

:: 15 mm construction grade substructure for wall cladding

:: 17 mm construction grade substructure for roof cladding

:: For fire rated/BAL applications, consult Metal Cladding Systems; a

fireproof substrate will be required.

Advantages:: Suitable for commercial and residential projects

:: Low fuss alternative to Standing Seam, suitable for

installers and/or builders missing appropriate seam closing

tools

:: Attractive vertical fin, unique to Snaplock and Nailstrip

systems

:: Standard pan widths of 180 mm, 280 mm and 480 mm

(for all materials, excluding zinc)

:: Standard zinc pan widths of 233 mm and 400 mm

:: Custom pan widths available for design individuality

:: Combine fixed panel widths or random patterns within

the same facade

:: Minimal maintenance compared to other cladding

materials, such as rendered brick and timber

MaterialsBrands | Aurubis | COLORBOND® | elZinc

GALVABOND® | Rheinzink® | Vestis | VMZINC ZINCALUME® | zintek®

Metals | Aluminium | Brass | Copper Galvanised Steel | Stainless Steel | Steel | Titanium Zinc

Metal Cladding Systems Pty Ltd. www.metalcsystems.com.au / [email protected]

Phone 03 9587 4554 / Fax 03 9587 4559 13-19 Malcolm Road, Braeside, Victoria, 3195

Installation Metal Cladding Systems recommend all profiles be installed by a qualified and experienced cladding installer. All complimentary flashings

and cappings are available from Metal Cladding Systems, via sister company, Bayside Flashing & Ventilations Pty Ltd.

All Snaplock applications must use a construction grade substrate. When working with zinc, on wall cladding applications a 20 mm

continuous ventilation gap beneath the substrate, and a 40 mm gap on roof installations, must be allocated (note, this is for zinc only). The

substrate should be wrapped in a moisture proof membrane before cladding panels are laid. Approved stainless steel clips must be used to

fix each panel over the membraned substrate, in conjunction with countersunk screws For detailed installation instructions and expert advice, please contact Metal Cladding Systems directly.

Limitations

:: Different materials allow for different panel widths and lengths. Speak with Metal Cladding Systems to confirm your material’s capability

and recommended pan widths for minimal wastage.

:: If your project requires material sizes outside the dimensions noted in this document, enquire about Metal Cladding Systems’ on-site

fabrication.

:: If you’re thinking of using Snaplock in a non-standard application, confirm your design with Metal Cladding Systems, to ensure all

elements are feasible.

NOT TO SCALE