Statement of Environmental Effects
No. 52 Drummond Rd Oyster Bay NSW 2225 Page 1 of 10
Statement of Environmental Effects
Proposal: Proposed alterations and additions to existing
dwelling and new pool Address: Lot 376 DP 14716, No. 52 Drummond Rd Oyster Bay
NSW 2225
Prepared by: Paperseed Design
Version/Date: Revision 01, 10 September 2018
Applicant: Grace Leung, Paperseed Design
Statement of Environmental Effects
No. 52 Drummond Rd Oyster Bay NSW 2225 Page 2 of 10
Contents1 Introduction ......................................................................................................................................... 3
2 Site suitability ....................................................................................................................................... 4
3 Present and previous uses of the land ................................................................................................. 4
4 Compliance with development standards ........................................................................................... 5
5 Access and traffic ................................................................................................................................. 5
6 Privacy, views and overshadowing ...................................................................................................... 5
7 Drainage ............................................................................................................................................... 7
8 Erosion and sediment control .............................................................................................................. 7
9 Energy efficiency .................................................................................................................................. 7
10 Site management ............................................................................................................................... 8
11 Finishes Schedule ............................................................................................................................... 8
12 Variation Justification Statement ....................................................................................................... 8
13 Conclusion ........................................................................................................................................ 10
14 Appendix .......................................................................................................................................... 10
Statement of Environmental Effects
No. 52 Drummond Rd Oyster Bay NSW 2225 Page 3 of 10
1IntroductionThe proposal consists of the following works at Lot 376 DP 14716, No. 52 Drummond Rd Oyster Bay
NSW 2225
Proposed alterations and additions to existing dwelling and new pool
The statement accompanies plans prepared by:
Architectural Plans by: Paperseed Design
Basix Plans by: Paperseed Design
In this document, the scheme is presented and appraised having regard to the relevant planning
controls of Sutherland Shire Development Control Plan 2015 and Sutherland Shire LEP 2015.
Statement of Environmental Effects
No. 52 Drummond Rd Oyster Bay NSW 2225 Page 4 of 10
2SitesuitabilityThe subject site is located at No. 52 Drummond Rd Oyster Bay NSW 2225. The site is 659m2 in size,
single frontage rectangular block, with frontage to Drummond Road facing North. The site steeply
slopes from the North side of the property to the South side of the property. The site is located
700m walking distance to a Bus Stop and 1.2km distance to Como Station.
The site is zoned ‘R2’, which permits dwelling houses in the LEP requirements. Adjoining
development surrounding the property include a mixture of single and two storey dwellings, varying
in age and styles.
The proposed property meets the local planning objectives being compatible with the established
character and streetscape. The proposed property is of a scale and density that is compatible with
the predominantly single dwelling character of the locality.
Figure 1 ‐ Location of house
3PresentandprevioususesofthelandThe present use of the site is a single storey weatherboard clad dwelling. The present uses of
adjoining land are residential dwellings.
There are no potentially contaminating activity on the property or nearby the property that we are
aware of. No testing of the site for land contamination has been done.
Statement of Environmental Effects
No. 52 Drummond Rd Oyster Bay NSW 2225 Page 5 of 10
4CompliancewithdevelopmentstandardsThe following planning instruments impact on the proposed development:
The Sutherland Shire Development Control Plan 2015
The Sutherland Shire Local Environment Plan 2015
The proposed development complies with the requirements of each code that is set out by
Sutherland Shire Council. Refer to the compliance table below:
Site Area 659m2
FSR 0.55:1 231m2 0.35:1 (COMPLIES)
Height 8.5m2 8.5m (COMPLIES)
Landscape area 35% 272m2 41.2% (COMPLIES)
Native Trees (4 minimum) 3 existing native trees at front setback, 2 new native trees planted at rear
5AccessandtrafficThe proposal includes 2 car lock up garage parking for its residence. Vehicle access is proposed via
Drummond Road
The site is located 700m walking distance to a Bus Stop and 1.2km distance to Como Station.
6Privacy,viewsandovershadowingVisualPrivacyWindows placed relative to adjacent dwellings and common areas have been designed to prevent
overlooking by minimizing side windows and facing windows to the front and rear.
There are no views between living rooms and the private yards of other dwellings. The outlook from
the balcony to the rear neighbour is obscured by trees, hence there is no overlooking into rear
neighbours. Refer to Figure 2.
The pool cannot be seen from the street as the site slopes steeply from the street to the rear. The
view from the street to the front of the house is also obscured by trees. Refer to Figure 4.
Statement of Environmental Effects
No. 52 Drummond Rd Oyster Bay NSW 2225 Page 6 of 10
Figure 2 – View to rear neighbour – showing privacy of trees obscuring view
AcousticPrivacyBedrooms have been separated from outdoor areas and parking areas, where they are placed on the
second storey.
Living rooms have been directed to face the rear yard, away from adjoining properties.
The external air‐conditioning unit and swimming pool pump equipment will be acoustically screened
to ensure equipment will not exceed an LAeq (15min) of 5dB (A) above background noise at the
property boundary.
ViewsNo view will be affected by the proposed development.
OvershadowingThe proposed development has been orientated to maximise natural light penetration to indoor
areas, with northern windows that allow penetrate to the rear living areas.
The rumpus room in the proposed development has 9 hours of direct sunlight between 9am and
3pm in midwinter.
The private open space at the rear South has at least 3 hours of direct sunlight at 9am and 3pm.
Additionally, the private open space at the North corner has 3 hours of direct sunlight between 9am
and 12am. These private open areas equate over 10m2 of area that has 3 hours of direct sunlight.
Neighbouring dwellings have not been affected by the proposed development, allowing minimum 3
hours of solar access to living and private open spaces, between 9am and 3pm during midwinter.
Statement of Environmental Effects
No. 52 Drummond Rd Oyster Bay NSW 2225 Page 7 of 10
7DrainageRefer to stormwater engineer’s drawings.
8ErosionandsedimentcontrolThe proposed development takes into consideration prevention of erosion and control sediment on
the site, with use of:
Sediment barrier fencing
Kerb inlet sediment traps
Stabilized access across driveway
Covering of stockpile storage and building materials
Refer to Erosion and Sediment Control Plan
9EnergyefficiencyThe proposed development has been orientated to maximise living areas to face the north, with the
rumpus room facing north.
A combination of setback of balconies, shading and blinds have been provided to the windows to
maximise summer shade and minimise winter shade.
Insulation proposed for the development meets the requirements for Basix.
Windows have good natural cross ventilation.
All heating, cooling and lighting systems meet the requirements for Basix.
The clothes drying space is located at the South with solar access from 12am‐3pm.
Statement of Environmental Effects
No. 52 Drummond Rd Oyster Bay NSW 2225 Page 8 of 10
10SitemanagementThe proposed development takes into consideration the site management to ensure public safety
and minimise public inconvenience:
Perimeter fencing to restrict public access to the construction site. Storage of building materials and equipment, bin containers and material stockpiles located at
the flat area of the site. Any loose materials will be covered. Signs will be placed at the front fence to direct pedestrians for site contacts prior to entry. The access point for vehicles will be via the existing driveway. Refer to Erosion and Sediment Control Plan.
11FinishesScheduleLocation Material
Basement & Ground Floor External Walls Lightweight ‘Harditex’ rendered cladding in Quarter Lexicon – James Hardie
First Floor External Walls ‘Snaplock’ Metal cladding in ‘Monument’
Windows & Louvers Aluminium powdercoated in ‘black’ and ‘natural white’
Roofing ‘Snaplock’ Metal cladding in ‘Monument’
Refer to product specifications in the Appendix.
12VariationJustificationStatementThe proposal does not meet the numerical controls for the garage setbacks, which requires the
garage to be setback 1m behind the building line. The proposed setback for the garage is zero
setback on the front boundary. The justification for the zero setback is due to the pre‐existing
location of the house and the steep slope of the site. The characteristics of the streetscape show
that garages are located on the front boundary, hence the zero setback would be justified. See
Figure 3.
The proposal does not meet the numerical controls for the setbacks for the site, which require
maximum 60% depth being 28.41m. The proposed depth of the dwelling is 33.162m. The
justification for the non‐compliance is due to the pre‐existing location of the site being significantly
set back towards the rear of the property. The noncompliance does not affect any amenities to the
neighbours, where there are no issues with overlooking into the rear with trees obscuring views and
there is minimal impact on overshadowing. Refer to Figure 2.
Additionally, the proposal does not meet the numerical controls for the deep soil landscaping
requirements at the front of the building line, which require 50% deep soil landscaping within the
street frontage, being 101m2. The proposed deep soil landscaping within the street frontage is
87m2. The justification for the noncompliance is due to the pre‐existing location of the existing
dwelling being significantly set back towards the rear of the property. Being setback significantly
means that there would be significantly more deep soil landscaping that the DCP standard. There is
Statement of Environmental Effects
No. 52 Drummond Rd Oyster Bay NSW 2225 Page 9 of 10
also more overall deep soil landscaping than the minimum DCP requirements of 35%, with the
proposal providing 41.2% of overall deep soil landscaping. Moreover, with the set location of the
garage, this also affects the deep soil requirement, hence the noncompliance would be justified.
Refer to Figure 4 showing landscaping at front setback.
Figure 3 – Garage and carport on front boundary line along Drummond Road
Statement of Environmental Effects
No. 52 Drummond Rd Oyster Bay NSW 2225Page 10 of 10
Figure 4 – View to front of house showing steep slope to rear & landscaping at front setback
13ConclusionIn conclusion, the proposal compliant and consistent with the relevant controls:
Compliments the existing streetscape of the area
Complies with the development standards
Complies with traffic and access requirements
Complies with Privacy, Acoustic and overshadowing
Complies with energy requirements
Complies with sediment and erosion control requirements
The proposal is consistent with complying with the Sutherland Shire Control Plan 2015 and therefore
recommended that Council give supportive consideration to the proposed development application.
14AppendixProduct specifications attached.
22
CLA
DD
ING
James Hardie Product Catalogue
HardieTex™ systemHardieTex™ system is a strong, pre-primed base
sheet that is finished on-site with a specialised
texture coat system*, which includes joint
reinforcement. HardieTex™ system is the original
way to create a decorative, monolithic rendered
look without the need for masonry.
HardieTex™ system is suitable for use as
an external cladding in residential homes,
including alterations and additions, where a
lightweight system with a monolithic rendered
look is required. Ideal for full wrap or composite
construction designs on either timber or light
gauge steel framed homes.
HardieTex™
sheet
Product Code
Length (mm)
Width (mm)
Thickness (mm)
Mass (kg/m2)
Coverage per Panel (m2)
400293 2,440 900 7.5 11.33 2.20
401651 2,440 1,200 7.5 11.33 2.93
400295 2,725 900 7.5 11.33 2.45
400294 2,725 1,200 7.5 11.33 3.27
400296 3,000 900 7.5 11.33 2.70
400291 3,000 1,200 7.5 11.33 3.60
Selling units per pack: 30 sheets or each
23
CLA
DD
ING
James Hardie Product Catalogue
James Hardie™ 7.5mm PVC Starter StripA perforated PVC extrusion, used with HardieTex™ base sheet to provide a straight edge to finish the texture coating or used with PrimeLine™ Newport or Summit weatherboard to kick out the bottom row to the correct angle.Length: 3,000mmSelling Unit: 25 per pack
HardieTex™ 7.5mm PVC Z FlashingA PVC extrusion for use with HardieTex™ system to provide an alternative detail option at horizontal control joints.Length: 3,000mmSelling Unit: 25 per pack
305568 305569
HardieDrive™ Screws 32mm long A class 3 finish self-tapping wing-tipped screw for fastening to 0.8mm to 1.6mm BMT steel frames.Selling Unit: 500 per box
HardieDrive™ Screws 40mm long A class 3 finish self-tapping wing-tipped screw for fastening to 0.8mm to 1.6mm BMT steel frames.Selling Unit: 500 per box
305532 305533
James Hardie™ Fibreshears Electric tool for cutting fibre cement sheets.Selling Unit: 1 each
Villaboard™ Knife A score and snap knife designed to efficiently cut through James Hardie™ external cladding and internal lining products ≤9mm thick. Selling Unit: 12 per pack
300653 305915
HardieBlade™ Saw Blade 185mm A poly-diamond blade for fast and clean cutting of James Hardie™ fibre cement.Diameter: 185mmSelling Unit: 1 each
HardieBlade™ Saw Blade 254mm A poly-diamond blade for fast and clean cutting of James Hardie™ fibre cement.Diameter: 254mmSelling Unit: 1 each
300660 303375
James Hardie™ Joint Sealant^ 300mL cartridge A general purpose, paintable, exterior grade polyurethane joint sealant.300mL cartridgeSelling Unit: 20 per box
James Hardie™ Joint Sealant^ 600mL sausage A general purpose, paintable, exterior grade polyurethane joint sealant.600mL sausageSelling Unit: 20 per box
305534 305672
Accessories & Tools Supplied by James Hardie
Notes: All dimensions and masses provided are approximate only and subject to manufacturing tolerances. Masses are based on equilibrium content of product. Products are to be installed in accordance with the relevant and current Product Installation Guide and Technical Documentation. For information relating to installation, best practices, warnings and warranties visit www.jameshardie.com.au or phone us on 13 11 03. Refer to the relevant and current Product Installation Guide for accessories and/or tools not supplied by James Hardie.
Key: * Not supplied by James Hardie. To be applied in accordance with the texture coat manufacturer’s guidelines. ^ Not to be used in fire applications.
54
Altra Shutters | Interior | ExteriorDurable | Lockable | Sliding | Folding | Hinged | Fixed | Increased View
1 Altra Sliding Shutters. Wide Louvers, minimum frame, maximum view. 2 Altra Hinged shutters 3 Altra Exterior Multi-fold and fixed panels above, custom colour 4 Altra Fixed panels raked at top 5 and 6 Altra Exterior Multi-fold and fixed panels below, custom colour 7 Altra wall mount fixed U Chanel 100mm angle 8 Multi-fold with Flush Bolt. and recessed P94 track 9 Flush Bolt. 10 Key Lock Double Shoot Bolt 11 BRS (Bottom Roll Sliding) Tracks 12 Altra P94 Bottom track for top hang sliding and Bi-fold shutters 13 Recessed P94 track.
Options: Flush Bolts | Key Locks | Colours: Silver Anodised, Standard Powder Coat or Custom Colours.
3
1 Maximise the view with Sliding Altra 2 Altra Multifold hinged
Multifold Altra 4 Raked top - Altra Fixed U Channels 7 Altra fixed panel with 100mm angle 8 Altra Multifold
5 Altra Multifold and fixed panel 6 Altra Multifold and fixed panel
9 10 12 1311
Snaplock:: Modern take on traditional systems :: Suitable for roof and wall cladding :: Multiple laying pattern options :: Concealed fixing with no joint crimping :: Contemporary, linear aesthetic
Overview
Snaplock is ideal for modern architectural developments. Providing a similar
aesthetic to Standing Seam, Snaplock doesn’t require seam closing tools, as the profile is designed to “snap”
together.
Product Specs:: 25 mm or 38 mm rib heights (from base to rib top)
:: 165 mm to 500 mm pan widths, rib to rib (material dependant)
:: Up to 9000 mm long panels (material dependant)
:: Concealed fixing with countersunk screws and approved clips
:: Panels can be laid horizontally, vertically and diagonally
:: Custom curved systems available
:: 15 mm construction grade substructure for wall cladding
:: 17 mm construction grade substructure for roof cladding
:: For fire rated/BAL applications, consult Metal Cladding Systems; a
fireproof substrate will be required.
Advantages:: Suitable for commercial and residential projects
:: Low fuss alternative to Standing Seam, suitable for
installers and/or builders missing appropriate seam closing
tools
:: Attractive vertical fin, unique to Snaplock and Nailstrip
systems
:: Standard pan widths of 180 mm, 280 mm and 480 mm
(for all materials, excluding zinc)
:: Standard zinc pan widths of 233 mm and 400 mm
:: Custom pan widths available for design individuality
:: Combine fixed panel widths or random patterns within
the same facade
:: Minimal maintenance compared to other cladding
materials, such as rendered brick and timber
MaterialsBrands | Aurubis | COLORBOND® | elZinc
GALVABOND® | Rheinzink® | Vestis | VMZINC ZINCALUME® | zintek®
Metals | Aluminium | Brass | Copper Galvanised Steel | Stainless Steel | Steel | Titanium Zinc
Metal Cladding Systems Pty Ltd. www.metalcsystems.com.au / [email protected]
Phone 03 9587 4554 / Fax 03 9587 4559 13-19 Malcolm Road, Braeside, Victoria, 3195
Installation Metal Cladding Systems recommend all profiles be installed by a qualified and experienced cladding installer. All complimentary flashings
and cappings are available from Metal Cladding Systems, via sister company, Bayside Flashing & Ventilations Pty Ltd.
All Snaplock applications must use a construction grade substrate. When working with zinc, on wall cladding applications a 20 mm
continuous ventilation gap beneath the substrate, and a 40 mm gap on roof installations, must be allocated (note, this is for zinc only). The
substrate should be wrapped in a moisture proof membrane before cladding panels are laid. Approved stainless steel clips must be used to
fix each panel over the membraned substrate, in conjunction with countersunk screws For detailed installation instructions and expert advice, please contact Metal Cladding Systems directly.
Limitations
:: Different materials allow for different panel widths and lengths. Speak with Metal Cladding Systems to confirm your material’s capability
and recommended pan widths for minimal wastage.
:: If your project requires material sizes outside the dimensions noted in this document, enquire about Metal Cladding Systems’ on-site
fabrication.
:: If you’re thinking of using Snaplock in a non-standard application, confirm your design with Metal Cladding Systems, to ensure all
elements are feasible.
NOT TO SCALE