T - Beam (USD-Ultimate Strength Design)

22
OF SCIENCE & TECHNOLOGY DEPARTMENT OF CIVIL ENGINEERING CE-416 PRE-STRESSED CONCRETE LAB SESSIONAL PRESENTED BY: S. M. RAHAT RAHMAN ID NO:10.01.03.044 COURSE TEACHERS: MUNSHI GALIB MUKTADIR SABREENA NASRIN 10/17/2022 1

Transcript of T - Beam (USD-Ultimate Strength Design)

AHSANULLAH UNIVERSITY OF

SCIENCE & TECHNOLOGY

DEPARTMENT OF CIVIL ENGINEERING

CE-416PRE-STRESSED CONCRETE LAB

SESSIONALPRESENTED BY:

S. M. RAHAT RAHMANID NO:10.01.03.044

COURSE TEACHERS:MUNSHI GALIB MUKTADIR

SABREENA NASRIN10/17/2022 1

T BEAM DESIGN : SINGLY & DOUBLY : USD

10/17/2022 2

USD (ULTIMATE STRENGTH DESIGN METHOD) T-BEAM T - BEAM ACTS LIKE SINGLY REINFORCED BEAM CONTINUOUS T – BEAM EFFECTIVE FLANGE WIDTH OF T-BEAM STRENGTH ANALYSIS ANALYSIS OF T - BEAM T BEAM MOMENT CALCULATION

CONTENTS

10/17/2022 3

ULTIMATE STRENGTH DESIGN(USD)

Assuming tensile failure condition

Additional strength of steel after yielding

ACI code emphasizes this method.

10/17/2022 4

T-BEAM

Concrete beams are often casted integrally with the slab and formed a “T” – shaped beam.

These beams are very efficient .

Here slab portion carries the compressive load and web portion carries the tension .

10/17/2022 5

T-BEAMOccurrence and Configuration of T-Beams

• Common construction type• The slab forms the beam flange, while the part of the beam projecting below the slab forms is what is called web or stem.

10/17/2022 6

SINGLY REINFORCED BEAM

10/17/2022 7

Tension Zone

Compression Zone

Figure : Singly Reinforced Beam for positive moment condition

DOUBLY REINFORCED BEAM10/17/2022 8

Figure : Doubly Reinforced Beam for positive moment condition

Compression Zone

Tension Zone

T BEAM BEHAVES AS SINGLY REINFORCED BEAM

10/17/2022 9

CONTINUOUS T-BEAM

T-Action

Rectangular

10/17/2022 10

CONTINUOUS T-BEAM T Versus Rectangular Sections

When T-shaped sections are subjected to negative bending moments, the flange is located in the tension zone.

On the other hand, when sections are subjected to positive bending moments, the flange is located in the compression zone and the section is treated as a T-section.

10/17/2022 11

EFFECTIVE FLANGE WIDTHFrom ACI 318, Section 8.10.2

Effective Flange Width : Condition 1

For symmetrical T-Beam or having slab on both sides a) 16 hf + bw

b) Span/4 c) c/c distance

10/17/2022 12

EFFECTIVE FLANGE WIDTHFrom ACI 318, Section 8.10.2

Effective Flange Width : Condition 2 Beams having slabs on one side only a) bw + span/12 b) bw + 6hf

c) bw + 1/2 * beam clear distance

10/17/2022 13

EFFECTIVE FLANGE WIDTH

From ACI 318, Section 8.10.2

Effective Flange Width :Condition 3

Isolated T Beam

a) beff 4 b≤ w

b) hf b≥ w/2

10/17/2022 14

T - SECTION (STRENGTH ANALYSIS)

Strength Analysis :

1st case : (N.A. is with in the flange)

Analysis as a rectangular beam of width

=

10/17/2022 15

T-SECTION (STRENGTH ANALYSIS)

Case 1 : (N. A. is with in Flange)

10/17/2022 16

hf

Strain Diagram

Stress Diagram

T-SECTION (STRENGTH ANALYSIS)

Case 2 : (N. A. is with in Web)

10/17/2022 17

ANALYSIS OF T-BEAM

1810/17/2022

Analysis of T-Beams - ( a > hf)

Consider the total section in two parts:

1) Flange overhangs and corresponding steel;2) Stem and corresponding steel;

N.A. N.A.

b - bw

bw

ANALYSIS OF T BEAM

Case-1

0.85 fc’ (b-bw) hf = As2 fy

Case-2 0.85 fc’ bw a = As1 fy

0.85 fc’ bw a + 0.85 fc’ (b-bw) hf = As fy

Where,

As1 = As – Asf As2 = Asf

10/17/2022 19

εc=0.003

d

c

0.85fc’ a/

2

d-a/2

C

T

Strain Diagram

Stress Diagram

As

hf

T BEAM MOMENT CALCULATION

For :

10/17/2022 20

b

bw

n n1 n2

n1 s sf y

fn2 sf y

2

2

M M MaM A A f d

hM A f d

fha

THANK YOU

10/17/2022 21

10/17/2022 22ANY QUESTION ?