Split System Rating

13
2425 South Yukon Ave - Tulsa, Oklahoma 74107-2728 - Ph. (918) 583-2266 Fax (918) 583-6094 AAONEcat32 Ver. 4.282 (SN: 6092064-) 1A 1B 1C 1D 2 3 4 5A 5B 5C 6A 6B 6C 7 8 9 10 11 12 13 14A 14B 15 16 17 18 19 20 21 22 23 V3-BRB-8-0-161C-3B2:ADFE-HEH-000-0A0-00A00F0-00-B00000000 Air Handling Unit Tag: Split AHU # 1 CFA-007-A-A-8-DC00H:A-D0-E0-00-000-L-FE00-00E0G00-0A000DB Condensing Unit Tag: Split CU # 1 Job Information Unit Information Job Name: Approx. Weights AHU/CU: Job Number: Supply CFM/ESP: Site Altitude: Refrigerant Ambient Temperature: Return Temperature: BCH Life Guard 659 / 474 lbs. (±5%) H-19 900 / 0.5 in. wg. 0 ft R-410A 93 ºF DB / 79 ºF WB 80 ºF DB / 67 ºF WB Static Pressure External: Economizer: Evaporator: Heating: Filters Clean: Cabinet: Dirt Allowance Total: 0.50 in. wg. 0.00 in. wg. 0.29 in. wg. 0.03 in. wg. 0.04 in. wg. 0.00 in. wg. 0.15 in. wg. 1.01 in. wg. Cooling Section Heating Section Gross Net Total Capacity: Sensible Capacity: Latent Capacity: Mixed Air Temp: Entering Air Temp: Lv Air Temp (Coil): Lv Air Temp (Unit) Evap Suction Temp: Supply Air Fan: SA Fan RPM / Width: Evaporator Coil: Evaporator Face Velocity: 68.27 67.43 MBH 33.82 32.98 MBH 34.45 MBH 93.00 ºF DB 79.00 ºF WB 93.00 ºF DB 79.00 ºF WB 56.50 ºF DB 56.44 ºF WB 57.33 ºF DB 56.76 ºF WB 46.58 ºF 1 x 250AY @ 0.28 BHP 2237 / 3.150" 3.7 ft² / 6 Rows / 12 FPI 245.5 fpm PreHeat Type: Std (No Preheat) Auxiliary Heating Type*: Heating CFM: Total Capacity: OA Temp: RA Temp: Entering Air Temp: Leaving Air Temp: Input: Heater Qty (Hi/Low): Electric Heat FLA: Electric Heat 900 35.8 MBH 40.0 DB / 33.0ºF WB 75.0 ºF DB / 65.0 ºF WB 40.0 ºF DB / 33.0 ºF WB 76.9 ºF DB / 51.5 ºF WB 10.5 kW 2 29.1 Re-Heat Coil: Capacity: 18 MBH LA DB / WB: 75.00 ºF / 63.21 ºF RH: 52% EER - ARI Listing Information Application EER @ Op. Conditions: Condensing Unit EER @ Op. Conditions: 11.9 12.7 AH Electrical Data Rating: Minimum Circuit Amp: Unit FLA: Maximum Overcurrent: 208/3/60 40 31.9 40 CU Electrical Data Rating: Minimum Circuit Amp: Unit FLA: Maximum Overcurrent: 208/3/60 28 23 45 Qty HP VAC Phase RPM FLA RLA Compressor 1: 1 208 3 20.4 Condenser Fans: 1 0.33 208 1 1075 2.8 Supply Fan: 1 1.10 208 3 3450 2.8 *Motor heat is not included. Connection Sizes System Suction Line Liquid Line Hot Gas Reheat 1 1.13" 0.5" 0.88" Split System Rating Date Created/Modified: 5/1/2019 1:00:50 PM Using Ver 4.282 (OSN# 0123456) Date Printed: 5/1/2019 1:06:25 PM

Transcript of Split System Rating

2425 South Yukon Ave - Tulsa, Oklahoma 74107-2728 - Ph. (918) 583-2266 Fax (918) 583-6094AAONEcat32 Ver. 4.282 (SN: 6092064-)

1A

1B

1C

1D

2

3

4

5A

5B

5C 6A

6B

6C

7

8

9

10

11

12

13

14A

14B

15

16

17

18

19

20

21

22

23

V 3- BRB-8- 0-16 1C -3B2 :ADFE- HE H-00 0- 0A0- 00 A00F 0- 00-B00 00 0000 Air Handling Unit Tag: Split AHU # 1

CFA-007-A-A-8-DC00H:A-D0-E0-00-000-L-FE00-00E0G00-0A000DB Condensing Unit Tag: Split CU # 1

Job Information Unit Information

Job Name: Approx. Weights AHU/CU: Job Number: Supply CFM/ESP: Site Altitude: Refrigerant

Ambient Temperature: Return Temperature:

BCH Life Guard 659 / 474 lbs. (±5%)H-19 900 / 0.5 in. wg.0 ftR-410A

93 ºF DB / 79 ºF WB80 ºF DB / 67 ºF WB

Static Pressure

External: Economizer: Evaporator: Heating: Filters Clean: Cabinet: Dirt Allowance Total:

0.50 in. wg. 0.00 in. wg.0.29 in. wg. 0.03 in. wg.0.04 in. wg. 0.00 in. wg.0.15 in. wg. 1.01 in. wg.

Cooling Section Heating Section

Gross Net Total Capacity: Sensible Capacity: Latent Capacity: Mixed Air Temp: Entering Air Temp: Lv Air Temp (Coil): Lv Air Temp (Unit) Evap Suction Temp: Supply Air Fan: SA Fan RPM / Width:

Evaporator Coil: Evaporator Face Velocity:

68.27 67.43 MBH33.82 32.98 MBH34.45 MBH93.00 ºF DB 79.00 ºF WB93.00 ºF DB 79.00 ºF WB56.50 ºF DB 56.44 ºF WB57.33 ºF DB 56.76 ºF WB46.58 ºF1 x 250AY @ 0.28 BHP2237 / 3.150"

3.7 ft² / 6 Rows / 12 FPI245.5 fpm

PreHeat Type: Std (No Preheat)

Auxiliary Heating Type*: Heating CFM: Total Capacity: OA Temp: RA Temp: Entering Air Temp: Leaving Air Temp: Input: Heater Qty (Hi/Low): Electric Heat FLA:

Electric Heat90035.8 MBH40.0 DB / 33.0ºF WB75.0 ºF DB / 65.0 ºF WB40.0 ºF DB / 33.0 ºF WB76.9 ºF DB / 51.5 ºF WB10.5 kW229.1

Re-Heat Coil: Capacity: 18 MBH LA DB / WB: 75.00 ºF / 63.21 ºF RH: 52%

EER - ARI Listing Information

Application EER @ Op. Conditions: Condensing Unit EER @ Op. Conditions:11.9 12.7

AH Electrical Data

Rating: Minimum Circuit Amp: Unit FLA: Maximum Overcurrent:

208/3/60 4031.9 40

CU Electrical Data

Rating: Minimum Circuit Amp: Unit FLA: Maximum Overcurrent:

208/3/60 2823 45

Qty HP VAC Phase RPM FLA RLA Compressor 1: 1 208 3 20.4 Condenser Fans: 1 0.33 208 1 1075 2.8 Supply Fan: 1 1.10 208 3 3450 2.8

*Motor heat is not included.

Connection Sizes

System Suction Line Liquid Line Hot Gas Reheat1 1.13" 0.5" 0.88"

Split System Rating

Date Created/Modified: 5/1/2019 1:00:50 PM Using Ver 4.282 (OSN# 0123456) Date Printed: 5/1/2019 1:06:25 PM

2425 South Yukon Ave - Tulsa, Oklahoma 74107-2728 - Ph. (918) 583-2266 Fax (918) 583-6094AAONEcat32 Ver. 4.282 (SN: 6092064-)

1A

1B

1C

1D

2

3

4

5A

5B

5C 6A

6B

6C

7

8

9

10

11

12

13

14A

14B

15

16

17

18

19

20

21

22

23

V 3- BRB-8- 0-16 1C -3B2 :ADFE- HE H-00 0- 0A0- 00 A00F 0- 00-B00 00 0000 Air Handling Unit Tag: Split AHU # 1

CFA-007-A-A-8-DC00H:A-D0-E0-00-000-L-FE00-00E0G00-0A000DB Condensing Unit Tag: Split CU # 1

Job Information

Job Name: BCH Life Guard Job Number: H-19

Reheat Line Data

Elbow Qty: 4 Line Length: 30'

Oil return to be installed at the lowest point of the system.

PipeOD

Equiv.Length

Temp.Loss (ºF)

Velocity(fpm)

Min TonsFor Oil Return

" '

Suction Line Data

Elbow Qty: 4 Line Length: 30' Flow Direction of Suction Line: Down

PipeOD

Equiv.Length

Temp.Loss (ºF)

Velocity(fpm)

Min TonsFor Oil Return

Qty. ofReq. Traps

" '

Liquid Line Data

Elbow Qty: 4 Line Length: 30' Vertical Lift: 10'

PipeOD

Equiv.Length

Temp.Loss (ºF)

Velocity(fpm)

Min SubcoolingFor Vertical Lift

" '

Line Sizing Information

Date Created/Modified: 5/1/2019 1:00:50 PM Using Ver 4.282 (OSN# 0123456) Date Printed: 5/1/2019 1:06:25 PM

2425 South Yukon Ave - Tulsa, Oklahoma 74107-2728 - Ph. (918) 583-2266 Fax (918) 583-6094AAONEcat32 Ver. 4.282 (SN: 6092064-)

1A

1B

1C

1D

2

3

4

5A

5B

5C 6A

6B

6C

7

8

9

10

11

12

13

14A

14B

15

16

17

18

19

20

21

22

23

V 3- BRB-8- 0-16 1C -3B2 :ADFE- HE H-00 0- 0A0- 00 A00F 0- 00-B00 00 0000 Air Handling Unit Tag: Split AHU # 1

CFA-007-A-A-8-DC00H:A-D0-E0-00-000-L-FE00-00E0G00-0A000DB Condensing Unit Tag: Split CU # 1

Job Information

Job Name: BCH Life Guard Job Number: H-19

Factory Supplied / Factory Installed

Quantity Description Part #: Location

Factory Supplied / Field Installed

Quantity Description Part #: Location- N/A - -

Field Supplied / Field Installed

Quantity Description Part #: Location- P-Trap(s) AHU

Refrigeration Accessories

Date Created/Modified: 5/1/2019 1:00:50 PM Using Ver 4.282 (OSN# 0123456) Date Printed: 5/1/2019 1:06:25 PM

Circuit #: 1

Date Created/Modified: 5/1/2019 1:00:50 PM Using Ver 4.282 (OSN# 0123456) Date Printed: 5/1/2019 1:06:25 PM

203 Gum Springs Road - Longview, TX 75602 - Ph. (903) 236-4403 Fax (903) 236-4463AAONEcat32 Ver. 4.282 (SN: 6092064-)

1A

1B

1C

1D

2

3

4

5A

5B

5C 6A

6B

6C

7

8

9

10

11

12

13

14A

14B

15

16

17

18

19

20

21

22

23

V 3- BRB-8- 0-16 1C -3B2 :ADFE- HE H-00 0- 0A0- 00 A00F 0- 00-B00 00 0000 Tag: Split AHU # 1

Job Name: BCH Life Guard Unit Submittal For: Job Number: H-19 Unit Submittal Date: May 01, 2019

Base Option Description

V Series Vertical Unit

3 Generation Third Generation

B Unit Size Up to 2,000 cfm

R Unit Orientation Right Hand Connections - Top Discharge, Back Intake (Vertical)

B Revision Second Revision

8 Voltage 208V/3Ø/60Hz

0 Corrosion Protection None

1 Cooling Type R-410A DX Cooling

6 Cooling Rows 6 Row Coil

1 Cooling Stages Single Circuit

C Cooling FPI 12 fpi

3 Heating Type Electric Heat

B Heating Designation 14 kW (10.5 kW @ 208V)

2 Heating Stages 2 Stage

Feature Option Description

A 1A. SA Blower Configuration 1 Blower + 1 High Efficiency EC Motor

D 1B. SA Blower Model 250 mm Backward Curved Plenum

F 1C. SA Blower Motor 800 W

E 1D. SA Blower Control/Contol Vendor VCC-X Orion Controls System

H 2. Refrigeration Options Modulating Hot Gas Reheat (MHGR)

E 3. Special Controls Make Up Air Controller - CV Cool + CV Heat

H 4. Additional Controls Remote Safety Shutdown Terminals

0 5A. Mixing Box - RA Damper Position Standard - None

0 5B. Mixing Box - OA Damper Position Standard - None

0 5C. Mixing Box - Damper Control Standard - None

0 6A. Filter Box - Pre Filter Box Standard - None

A 6B. Filter Box - Unit Filter 2" Pleated - 30% Eff.

0 6C. Filter Box - Final Filter Box Standard - None

0 7. Filter Options Standard - None

0 8. Coil Coating Standard - None

A 9. Expansion Valve Thermal Expansion Valves

0 10. Expansion Valve Controls None

0 11. External Paint Standard - None

F 12. Tonnage 7 ton Capacity

0 13. Energy Recovery Type Standard - None

0 14A. GPM Cooling Coil Standard

0 14B. GPM Heating Coil Standard

B 15. Control Panel Medium Control Panel - 25" x 22"

0 16. Shipping Splits Standard (No Shipping Split)

0 17. Energy Recovery Cabinet Standard - None

0 18. Preheat Standard - None

0 19. Exhaust Fan Standard - None

0 20. Crating Standard

0 21. Pulley Combination Standard - None

0 22. Warranty Standard - 1 Year Parts

0 23. Type Standard

Unit Submittal

Date Created/Modified: 5/1/2019 1:00:50 PM Using Ver 4.282 (OSN# 0123456) Date Printed: 5/1/2019 1:06:27 PM

2425 South Yukon Ave - Tulsa, Oklahoma 74107-2728 - Ph. (918) 583-2266 Fax (918) 583-6094AAONEcat32 Ver. 4.282 (SN: 6092064-)

1A

1B

1C

1D

2

3

4

5A

5B

5C 6A

6B

6C

7

8

9

10

11

12

13

14A

14B

15

16

17

18

19

20

21

22

23

V 3- BRB-8- 0-16 1C -3B2 :ADFE- HE H-00 0- 0A0- 00 A00F 0- 00-B00 00 0000 Tag: Split AHU # 1 Job Name: BCH Life Guard VCCX For: Job Number: H-19 VCCX Date: May 01, 2019

Hardware Included For VCCX Controller

Part # Included Parts Assigned Channel BACnet PointV87900 VCCX CONTROLLERV13050 OSA Temp/Hum Sensor EBUS2 communicating sensor AI:16,AI:17,AI:18,AI:19R82890 Supply Temp Sensor - Field Installed VCCX control point AI 3 AI:9V17180 EBUS DIST HUB EBUS5 distribution hub N/A

Supply Fan Control Signal 0-10VDC VCCX control point AO 1 AI:22R62330 Proof of Air Flow VCCX control point BI 1 BI:6

Safety Shut Down VCCX control point BI 8 BI:26Supply Fan Configured Relay point BI:63Heat 1 Configured Relay Point BI:64Heat 2 Configured Relay Point BI:65

VCCX Components

Date Created/Modified: 5/1/2019 1:00:50 PM Using Ver 4.282 (OSN# 0123456) Date Printed: 5/1/2019 1:06:27 PM

2425 South Yukon Ave - Tulsa, Oklahoma 74107-2728 - Ph. (918) 583-2266 Fax (918) 583-6094AAONEcat32 Ver. 4.282 (SN: 6092064-)

JOB INFORMATION: WHEEL SPECIFICATION: Job Name: Max RPM: Job Tag: Diameter x Qty: Rep Firm: CFM: Date: Tip Speed:

Inertia:

BCH Life Guard 3,450Split AHU # 1 11.2 in. x 1

90005/01/2019 6,548 FPM

3 WR²

OPERATING CONDITIONS: MOTOR SELECTION: Air Flow: Rated HP / Bypass: Static Pressure: Frame Size: Relief Dampers DP: Nominal RPM:

VAC/PH/HZ: TSP: Efficiency Site Altitude: Enclosure Type: TSP @ Sea Level: Max Inertial Load:

900 CFM 1.1 / No1.01 in. Wg. ECM0.00 in. Wg. 1760

208/3/601.01 in. Wg. Premium / 0.8550.00 Ft ODP1.01 in. Wg. 27 WR²

FAN PERFORMANCE: FAN SOUND POWER (Inlet/Outlet): RPM: Octave Band: (Re 10^-12 watts) BHP: 1 2 3 4 5 6 7 8 Efficiency: In/Out Velocity: Plenum Out Velocity: SOUND POWER A-Weighted: 69 / 73 dB

Max Duct SP with Blocked Airway: 1.9 in. Wg. @ 2237 rpm

22370.2851.1% 64 62 66 66 63 60 60 613913/1169 FPM 64 64 68 70 71 68 65 6310 FPM

RPM

BHP

SYSTEM

Efficiency

SP Surge

CFM Min

Supply Fan Model: 250AY @ 2237 RPM and 100% WidthDesign Conditions: 900 CFM @ 1.01" SP

CFM x 100010

SP1

0

BH

P

1

0

40%

20%

0%

RPM: 2237

BHP: 0.28

EFFICIENCY: 51.06

25.0" STAR Plenum

Date Created/Modified: 5/1/2019 1:00:50 PM Using Ver 4.282 (OSN# 0123456) Date Printed: 5/1/2019 1:06:28 PM

2425 South Yukon Ave - Tulsa, Oklahoma 74107-2728 - Ph. (918) 583-2266 Fax (918) 583-6094AAONEcat32 Ver. 4.282 (SN: 6092064-)

A1

A2

A3

A4

A5

1

2A

2B 3A

3B

4

5

6A

6B

6C

7

8A

8B

8C

8D

9

10

11

12

13

14

15

16

17

18

19

20

21

22

C FA -007-A -A-8 -D C00H :A-D0- E0 -00- 00 0-L- FE 00-0 0E 0G00-0 A0 00DB Tag: Split CU # 1

Job Name: BCH Life Guard Unit Submittal For: Job Number: H-19 Unit Submittal Date: May 01, 2019

Base Option Description

CF Generation CF - Condensing Unit

A Major Rev Major Revision

007 Unit Size Seven

A Series A Cabinet

A Revision Minor Revision

8 Voltage 208V/3Ø/60Hz

D Compressor Style R-410A Variable Capacity Scroll Comp

C Condenser Style Air-Cooled Condenser (Fin and Tube)

0 Configuration Standard

0 Coating Standard

H Staging 1 Variable Refrig System

Feature Option Description

A 1. Unit Orientation Horizontal Condenser Discharge Standard Access

D 2A. Refrigeration Control Adjustable Compressor Lockout

0 2B. Blank Standard

E 3A. Refrigeration Options Modulating Hot Gas Reheat [MHGR]

0 3B. Blank Standard

0 4. Refrigeration Accessories Standard

0 5. Blank Standard

0 6A. Unit Disconnect Type Standard Single Point Power Block

0 6B. Disconnect Size None

0 6C. Blank Standard

L 7. Accessories Phase & Brown Out Protection + Suction Pressure Transducer on Each Refrigeration System

F 8A. Control Sequence Makeup Air Unit Controller - CAV Cool + CAV Heat

E 8B. Control suppliers VCC-X (Main Controller in Air Handling Unit)

0 8C. Control Supplier Options Standard

0 8D. BMS Connection and Diagnostics Standard

0 9. Blank Standard

0 10. Blank Standard

E 11. Maintenance Accessories Remote Unit Start/Stop Terminals

0 12. Code Options Standard ETL U.S.A. Listing

G 13.Air Cooled Condenser Accessories Condenser Coil Guard + ECM Cond Fan / Head Pressure Control

0 14. Blank Standard

0 15. Blank Standard

0 16. Electrical Options Standard

A 17. Shipping Options Crating

0 18. Blank Standard

0 19. Blank Standard

0 20. Cabinet Material Standard - Galvanized Steel Cabinet

D 21. Warranty Extended Compressor Warranty - Years 2-5

B 22. Paint and SPAs Premium AAON Gray Paint Exterior

Unit Submittal

Date Created/Modified: 5/1/2019 1:00:50 PM Using Ver 4.282 (OSN# 0123456) Date Printed: 5/1/2019 1:06:51 PM

2425 South Yukon Ave - Tulsa, Oklahoma 74107-2728 - Ph. (918) 583-2266 Fax (918) 583-6094AAONEcat32 Ver. 4.282 (SN: 6092064-)

A1

A2

A3

A4

A5

1

2A

2B 3A

3B

4

5

6A

6B

6C

7

8A

8B

8C

8D

9

10

11

12

13

14

15

16

17

18

19

20

21

22

C FA -007-A -A-8 -D C00H :A-D0- E0 -00- 00 0-L- FE 00-0 0E 0G00-0 A0 00DB

Tag: Split CU # 1 Job Name: BCH Life Guard VCCX For: Job Number: H-19 VCCX Date: May 01, 2019

Hardware Included For VCCX Controller

Part # Included Parts Assigned Channel BACnet PointV61520 DIGITAL REFRIGERATION MODULER42680 Comp Discharge Temp A RSMD point TEMP1 AI:56V38391 Suction Pressure Sensor A RSMD point AI1 AI:48V38410 Discharge Pressure Sensor A RSMD point HP-1 AI:50R63950 Modulated Condenser Signal A RSMD point AO1 BI:

Comp Status Input A RSMD point BIN1Emergency Shutdown RSMD point BIN4 BI:81,82Condenser Enable AB RSMD Fixed Relay point BI:78,BI:85Comp Enable A RSMD Fixed Relay point AI:46

V12100 MODULATING HOT GAS REHEAT MODULEReheat HGR Valve MHGRV-X AI:42

VCCX Components

Date Created/Modified: 5/1/2019 1:00:50 PM Using Ver 4.282 (OSN# 0123456) Date Printed: 5/1/2019 1:06:51 PM