pctvvn2002a.pdf - Daikin

114
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the user's manual carefully before using this product. The user's manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. About harmonics, since this product is equipped with an inverter, harmonics will be generated. If local laws require the suppression of harmonics on the building, please take harmonic suppression measures on the electrical equipment side. Please contact your local sales company for details. If you have any enquiries, please contact your local importer, distributor and/or retailer. General Catalogue Cooling Only / Heat Pump 50 Hz VRV is a trademark of Daikin Industries, Ltd. VRV Air Conditioning System is the world’s first individual air conditioning system with variable refrigerant flow control and was commercialised by Daikin in 1982. VRV is the trademark of Daikin Industries, Ltd., which is derived from the technology we call “variable refrigerant volume.” ©All rights reserved 10/20 AK Specifications, designs and other content appearing in this brochure are current as of October 2020 but subject to change without notice. Cautions on product corrosion 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. Cooling Only / Heat Pump 50 Hz Số 74 Lê Lợi, P. Hưng Bình, TP. Vinh PCTVVN2002A

Transcript of pctvvn2002a.pdf - Daikin

• Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

• Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.

• Read the user's manual carefully before using this product. The user's manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.

• About harmonics, since this product is equipped with an inverter, harmonics will be generated. If local laws require the suppression of harmonics on the building, please take harmonic suppression measures on the electrical equipment side. Please contact your local sales company for details.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Gen

eral Catalo

gu

eC

oo

ling

On

ly / Heat Pu

mp

50 Hz

VRV is a trademark of Daikin Industries, Ltd.VRV Air Conditioning System is the world’s first individual air conditioning system with variable refrigerant flow control and was commercialised by Daikin in 1982.VRV is the trademark of Daikin Industries, Ltd., which is derived from the technology we call “variable refrigerant volume.”

©All rights reserved 10/20 AK

Specifications, designs and other content appearing in this brochure are current as of October 2020 but subject to change without notice.

Cautions on product corrosion1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to

install the outdoor unit close to the sea shore, contact your local distributor.

Cooling Only / Heat Pump 50 Hz

Số 74 Lê Lợi, P. Hưng Bình, TP. Vinh

PCTVVN2002A

1 2

First launched in Japan in 1982, the Daikin VRV system has been embraced by world markets for over 35 years. Daikin proudly introduces the advanced VRV system. By combining the technologies of VRV, VRT and VAV, we have attained both energy savings and comfortable air conditioning.

VRVX series / A series

movie

Energy savings & comfort• Uniting VRV, VRT and VAV technologies• Quiet operation

Design flexibility & easy installation• Automatic refrigerant charge function• Varied lineup of models

High reliability• Refrigerant cooled PCB• Double backup operation• Heavy anti-corrosion model

Exceeding Boundaries with Innovative Energy Savings New Products Information

VRV Development History

VRV User Benefits

VRV Overview

VRV X Series

VRV A Series

VRV H Series

VRV S High Efficiency Series

VRV IV S Series

VRV IV Q Series

VRV IV W Series

VRV IV Heat Recovery Hot Water System

Indoor Unit Overview

VRV Indoor Units

Residential Indoor Units

Air Handling Unit

Air Treatment Equipment

Control Systems

Precision Piping Method

Option List

Daikin Engineering Supports

3

5

7

9

13

31

49

67

81

89

105

119

133

135

141

145

147

149

151

153

154

155

157

159

161

162

163

165

166

167

168

169

171

172

173

174

175

176

193

207

211

225

C o n t e n t s

*VRV is a trademark of Daikin Industries, Ltd.

FXFSQ-A

FXFQ-A

FXZQ-A

FXCQ-A

FXEQ-A

FXDSQ-A

FXDQ-PD/ND

FXDQ-SP

FXSQ-PA

FXMQ-PA

FXMQ-P

FXUQ-A

FXHQ-MA/A

FXAQ-A

FXLQ-MA

FXNQ-MA

FXVQ-N

FXPQ-A

FXB(P)Q-P

FDXS-EA/C(A), CDXS-EA, FDXS-C

FTKJ-N, FTXJ-N

FTKS-D/B/F, FTXS-D/E/F

BPMKS-A

Type

Round Flow Cassette with Sensing

Round Flow Cassette

Compact Multi Flow Cassette

Double Flow Cassette

Single Flow Cassette

3D Airflow Duct with Sensing

Slim Duct (Standard)

Slim Duct (Compact)

Middle Static Pressure Duct

Middle-High Static Pressure Duct

High Static Pressure Duct

4-Way Flow Ceiling Suspended

Ceiling Suspended

Wall Mounted

Floor Standing

Concealed Floor Standing

Floor Standing Duct

Spot Air Conditioner

Clean Room Air Conditioner

Type

Slim Ceiling Concealed Duct

Wall Mounted

Wall Mounted

BP Units

3 4

New Products Information

A revolution in piping works for VRV system!Quiet, compact, designed for user comfort

Precision Piping MethodCompact Multi Flow Cassette

Personal air comfort delivered to large spaces

Spot Air Conditioner

The ideal air conditioning system for residential houses, small offices and shops

Higher energy efficiencyVRT Smart Control Quiet operation

Non-brazing workSave installation time without special skills

A complete redesigned controller focused to enhance user experience

Stylish Remote Controller

Two attractive colors to match any interiorCompact, measures only 85 x 85 mmEasy setting via Bluetooth App with smartphone (for Installer/Facility manager)Improved setback function to keep hotel room comfortable

Extended operation range up to 52°CHigh voltage shield PCBAutomatic refrigerant charge function

Compact & Elegant DesignFully-flat integration in standard architectural ceiling tilesEfficiency & ComfortTwo optional intelligent sensors improve energy efficiency and comfort.

The high external static pressure of 40 Pa enables installation in small installation spaces where the airflow direction needs to be diverted to avoid short circuits.Low height casing designIncreased actual piping length up to 120 m

FXZQ-A

FXPQ-ANo ducts required!

Header Pack(Packaged Refnet Headers)

Daikin Gas Tight Joint(Fire free connection for piping)

Save time using quick flare nut connection

Hot work permit is not necessary

Energy savings& comfort

High performance& reliability

Designflexibility ofinstallation

RSU(Y)Q-A

67Page

207Page

145Page

168Page

193Page

BRC1H61W (White) BRC1H61K (Black)

PresentationMovie

BHF-RHP6Z

BDGTA

5 6

The 1st Generation

2008

VRV-WIII series

2011

VRV IIIConnection to residential

indoor unit series

VRV IIIConnection to residential

indoor unit series

VRV Multi function seriesCooling/heating, hot water supply

2014

VRV IV S seriesVRV IV S series

VRV IVHeat recovery

2010

VRV III Q seriesReplacement use

1984

VRV D seriesCooling only

1990

VRV G seriesHeat pump

1995

VRV H seriesMade possible to connect to BMS using the DIII-NET

1999

VRV K Plus series

2002

VRV L seriesAdopted the new R-407C

refrigerant

2006

2007

VRV III-C seriesLow outdoor temp.

area use

VRV II MA series

2005

1992

VRV G seriesHeat recovery

1996

VRV K series

2000

VRV KA series

1988

VRV F seriesCooling only

VRV II M seriesAdopted the new R-410A

refrigerant

2004

VRV II-S series

2012

VRV IVCooling only / Heat pump

2015

VRV IV Heat Recovery Hot Water System

2016

2017

2018 2020

2019

1982

To meet the needs of the times, we've been continuously developing technologies as the leading air conditioning manufacturer in the world.

VRV Development History

Expansion of the country of sale

Sales companies well established in more than 70 countries

BrazilArgentinaChileColombiaPanamaPeru

South America

USAMexicoCanadaPuerto Rico

North America

UAESaudi ArabiaBahrainJordanOmanQatar

Middle East

AustraliaFijiNew CaledoniaNew ZealandTahiti

OceaniaIndiaVietnamThailandIndonesiaMalaysiaSingaporePhilippine

CambodiaMyanmarMaldivesNepalSeychellesPakistanSri Lanka

Asia

JapanChinaKoreaTaiwan

NetherlandsPolandPortugalFinlandGreeceHungary IrelandRomania SerbiaSlovakiaSwedenSwitzerlandTurkeyUkraine

ItalyFranceGermanySpainRussiaUKAustriaBelgiumBulgariaCroatiaCyprusCzechLithuaniaMacedonia

Europe

South AfricaAlgeriaBurkina FasoEgyptIvory CoastSenegalSudan

Africa

VRV series released in 1982

• 2.5-year development term • Completion of development in May, 1982• Technical award of Japan Society of Refrigerating & Air-conditioning Engineers in 1983

*VRV is a trademark of Daikin Industries, Ltd.

The birth of innovative products that changed the history of air conditioning technology

VRV IV W seriesWater cooled system

VRV IV W seriesWater cooled system

VRV IV Q seriesReplacement use

VRV A seriesCooling only

VRV X seriesCooling only

VRV X seriesCooling only

VRV H seriesHeat pump

VRV A MAXHeavy anti-corrosion

VRV X MAXHeavy anti-corrosion

VRV S High Efficiency SeriesVRV C seriesCooling only

VRV-WIIseries

VRV III-S series

VRV III series

7 8

VRVCooling tower

Garage

Malfunction MalfunctionEmergencyoperation

Emergencyoperation

BP unit

Min. sound level 19 dB(A)

VRV User Benefits

For property OWNERS

Varied lineup of models• With various types of indoor units available, comfortable airflow is ensured in every space.

Long piping provides more flexible system design• Maximum equivalent piping length between indoor and outdoor unit is 190 m.• Maximum height difference is 90 m.

Compatible with engineering software• Daikin provide the software, the simulation results, and drawing materials to support the building

information modeling (BIM) currently entering the mainstream in construction industries.

Energy efficient• Achieves your green building solution by Daikin’s innovative

energy-saving technology.

Automatic refrigerant charge function• Automates the charging of proper refrigerant amount to contribute to optimised operation efficiency,

higher quality and easier installation.

Lightweight and compact large-capacity single units• Easy to install and can be transported in elevators.

Simple piping, easy wiring• The REFNET piping system and DIII-NET system simplify refrigerant piping and control wiring installation.

For INSTALLERS

For CONSULTANT and DESIGN OFFICES

Comfortable environment• VRT Smart operation maintains the indoor temperature

and ensures a comfortable environment.

Residential indoor units• Residential indoor units can be connected and it is possible

to realise quiet operation.

• By remotely installing an BP unit, the noise of refrigerant passing though the piping can be reduced.

For USERS

High reliability• Refrigerant cooled PCB

Daikin’s unique refrigerant cooling helps maintain high cooling capacity even during high outdoor temperatures.

• Double backup operationUnit backup & Compressor backup ensure continuous operation. • Heavy anti-corrosion model

The heavy anti-corrosion models can provide durable operation at humid and seaside areas.Also, outdoor unit can be installed from 0 m from coastline.

Energy saving & comfortable environment• VRT Smart greatly reduces the energy by

optimising the capacity according to heat load, especially during low-load operation.

• Comfortable indoor environment is maintained at the time.

Efficient space utilisation• When construct a large-scale air conditioning

system on a single refrigerant system, space for air conditioning is drastically reduced.

• Even with a 20-storey building all of the outdoor units can be installed on the rooftop.

Refrigerant piping

Print circuit board

CADXpress

CADXpress

R-410A

9 10

Wide Variety of Series Models to Supply Total Air Solutions

From residential houses to large buildings, and from newly constructed to renovated buildings, VRV system meets a wide range of air conditioning needs and supplies total air solutions.

81Page

89Page

105Page

119Page

13Page

31Page

49Page

67Page

New heights in energy efficiencyduring actual operationThe VRV X series features new models specially developed for higher efficiency. All compressors used in outdoor units are new scroll compressors designed to enhance energy efficiency.

60HP 5856545250484644424038363432302826242220181614121086Single outdoor units

Double outdoor units

Triple outdoor units

Lineup

Especially designed for residential houses, small offices and shopsVRV IV S series aims to provide sufficient capacity, along with the compact size required by residential houses, small offices and shops. Outdoor units are designed to be slim and space saving, and offer 5 models to suit your needs.

HP 98654Cooling Only

Heat Pump

Lineup

Achieves space saving & excellent performance to meet the needs in various buildingsThe VRV H series achieves high efficiency in a design that is more compact and lightweight. It also offers comfort, easy installation, and high reliability to meet the needs in various buildings.

60HP 5856545250484644424038363432302826242220181614121086High-COP Type

Standard Type

Lineup

Saves space and delivers excellent performanceThe VRV A series achieves high efficiency in a design that is more compact and lightweight. It also offers comfort, easy installation, and high reliability to meet the needs in various buildings.

60HP 5856545250484644424038363432302826242220181614121086Single outdoor units

Double outdoor units

Triple outdoor units

Lineup

Especially designed for residential houses, small office and shopsNew VRV S High Efficiency Series achieves higher energy efficiency with a variety of function for comfort and high performance. A wide range of options for installation location and application are easily achieved by the low height casing, long piping length and other features.

HP 7654Cooling Only

Heat Pump

Lineup

RXUQ-AW

Heavy anti-corrosion model

Heat Pump Heat Pump

Cooling Only / Heat Pump

Cooling Only

Comfortable air conditioning and energy-efficient hot water heatingThis energy-efficient, multifunction system recovers waste heat generated by air conditioning, as energy to heat water. It is suitable for different business applications and provides flexible combination of VRV IV indoor units achieving comfort and aesthetic.

60HP 5856545250484644424038363432302826242220181614121086High-COP Type

Standard Type

Space Saving Type

Lineup

Cooling Only

Cooling Only

RXQ-AW

Heavy anti-corrosion model

For quick & high quality replacement use

VRV IV Q series, a replacement VRV unit, can be installed using existing refrigerant piping, so renovation of the air conditioning system can be carried out quickly and smoothly. This minimises inconveniences to activities and users in the building.

HP 484644424038363432302826242220181614121086Standard Type

Space Saving Type

Lineup

Water cooled system suitable for tall multi-storied buildings

Water cooled VRV IV W series utilises water as a heat source. The temperature of heat source water can be from 10°C to 45°C, and outdoor air temperature does not affect cooling capacity. The outside unit is compact and saves space in the machine room.

HP 363432302826242220181614121086Heat Pump

LineupRXYQ-A3-phase 4-wire system,

380-415 V/380 V, 50/60 Hz

RSU(Y)Q-A4-6 HP

7 HP: 1-phase, 220-240 V/220-230 V, 50/60 Hz : 3-phase, 380-415 V/380 V, 50/60 Hz

4 HP: 1-phase, 220-230 V/220 V, 50/60 Hz5-6 HP: 1-phase, 220-240 V/220-230 V, 50/60 Hz8-9 HP: 3-phase, 380-415 V, 50 Hz

RXQ-A3-phase 4-wire system,

380-415 V/380 V, 50/60 Hz

RWEYQ-T3-phase 4-wire system,

380-415 V/380 V, 50/60 Hz

RWHQ-T / HWHQ30A3-phase 4-wire system,

380-415 V/380 V, 50/60 Hz

RXUQ-A3-phase 4-wire system,

380-415 V/380 V, 50/60 Hz

RX(Y)MQ-A/B

RQ(Y)Q-T3-phase 4-wire system,

380-415 V/380 V, 50/60 Hz

Cooling Only / Heat Pump

Cooling Only / Heat Pump

11 12

Floo

r St

andi

ngCe

iling

Susp

ende

dC

ateg

ory

Cei

ling

Mou

nted

Cas

sett

eC

eilin

g C

once

aled

Duc

t

Wide Range Indoor Unit Lineup Create Comfortable Airflow

Note: For indoor units connectability, please refer to the indoor unit product lineups under individual outdoor unit series.

20

20

2.0

25 35

25 35

2.5 3.5

50 60 71

50 60 71

5.0 6.0 7.1Rated Capacity (kW)Type Model Name

Capacity Index

Slim CeilingConcealed Duct

Wall Mounted

Cooling Only

Heat Pump

FTKJ-NVMVW

FTXJ-NVMVW

Cooling Only

Heat Pump

FTKJ-NVMVS

FTXJ-NVMVS

Cooling Only

Heat Pump

FTKS-FVM

FTXS-FVMA

Cooling Only

Heat Pump

FDKS-EAVMB

CDXS-EAVMA

Cooling Only

Heat Pump

FDKS-C(A)VMB

FDXS-CVMA

Cooling OnlyHeat PumpHeat Pump

FTKS-DVMFTXS-DVMAFTXS-EVMA

Cooling Only FTKS-BVMA

(700 mm width type)

(900/1,100 mm width type)

VRV indoor units Residential indoor units with connection to BP units

FXDSQ-AVM3D Airflow Duct with Sensing

FXSQ-PAVEMiddle Static Pressure Duct

Capacity Range

Capacity Index 20

0.8 HP

20

1.6 HP

40

2.5 HP

63

3.2 HP

80

3 HP

71

4 HP

100

5 HP

125

6 HP

140

8 HP

200

10 HP

250

2 HP1.25 HP

32

62.531.25

1 HP

25Type Model Name

FXFSQ-AVMRound Flow Cassette with Sensing

Round Flow Cassette

Compact Multi Flow Cassette

Double Flow Cassette

Single Flow Cassette

Slim Duct (Standard)

Middle-High Static Pressure Duct

High Static Pressure Duct

Ceiling Suspended

Wall Mounted

Floor Standing

Concealed Floor Standing

4-Way Flow Ceiling Suspended

Outdoor-Air Processing Unit

FXVQ-NY1

FXVQ-NY16(high static pressure type)

Floor Standing Duct

Spot Air Conditioner

FXDQ-SPV1Slim Duct (Compact)

400

16 HP

500

20 HP

FXMQ-MFV1

Heat Reclaim Ventilator

Air Handling Unit

Heat Reclaim Ventilator with DX-Coil and Humidifier

VKM-GA(M)V1

VAM-GJVE

AHUR

Airflow rate 500-1000 m3/h

Airflow rate 150-2000 m3/h

Clean Room Air ConditionerFXBQ-PVE

FXBPQ-PVE

FXEQ-AV36

FXFQ-AVM

FXZQ-AVM

FXPQ-AVN

FXCQ-AVM

FXMQ-PAVE

FXMQ-PVM

FXHQ-AVM

FXUQ-AVEB

FXHQ-MAVE

FXAQ-AVM

FXLQ-MAVE

FXNQ-MAVE

FXDQ-PDVE(with drain pump)

FXDQ-PDVET(without drain pump)

FXDQ-NDVE(with drain pump)

FXDQ-NDVET(without drain pump)

(700 mm width type)

(900/1,100 mm width type)

6–120 HP

50

40 8071 100 125 140 200 25025 400 50050

New lineup

13 14

VRV X Series

VR

V X

Ser

ies

* Simulation conditions:• Location: Bangkok, Thailand

• System: Outdoor unit (10 HP) x 1

Indoor unit (2 HP, Round Flow with Sensing type) x 5

• Operation time: 8:00-20:00 5 days/week

• Outdoor units: New model: RXUQ10A (VRV X series)

Conventional model: RXQ10T (VRV IV)

* Cooling operation conditions: • Indoor temperature of 27ºCDB, 19ºCWB, and outdoor temperature of 35ºCDB.

Daikin’s VRV X series raised the standard of energy efficiency.

Greater energy savings during low-load operation

Higher Energy Efficiency Ratio (EER) for 10 HP

* Data source• Number of properties connected to the Air

Conditioning Network Service System: 42 projects

• Number of outdoor unit systems: 535 systems

• Data collection period: 8:00-18:00, weekdays

(excluding public holidays), from July 2015 to June

2016 in office buildings in Singapore.

10% 20% 30% 40% 50% 60% 70% 80% 90% 100%0

Load factor for the rated capacity

Op

erat

ion

per

iod

0

3

4

5

6

7

8

9

30% 40% 90% 100%50% 60% 70% 80% Load

Co

olin

g O

per

atio

n E

ER

8.84 8.42 8.197.37

6.435.69

5.084.45

Increased efficiencyduring low-load operation.

The key to innovativeenergy savings

Load factor of 50% or less

accounts for 80% of annual

operation period.

Conventional model New model

20%Lower

Annual powerconsumption

Single outdoor units

RXUQ6-20AYM(W)

Double outdoor units

RXUQ12-40AMYM(W)

Triple outdoor units

RXUQ18-20AM1YM(W)RXUQ42-60AMYM(W)

*(W): Heavy anti-corrosion model

6HP–60HP

Cooling Only

(16 kW) (168 kW)

New Heights in Energy Efficiency During Actual Operation

15 16

VRV X Series

VR

V X

Ser

ies

New intermediate pressure mechanism

Advanced Technologies

Back pressure control mechanism

Refrigerant leakage is minimized during low-load operationOptimally supply only for the needed capacity of indoor units

Advanced technologies for greater energy savings

• Reduces compressor load and minimizes operation loss so it is energy saving• Controls capacity according to load to ensure a constant room temperature for greater comfort.

By uniting advanced software and hardware technologies for greater energy savings during actual operation and combining the technologies of VRV, VRT and VAV, we have attained both energy savings and comfortable air conditioning.

Co

mp

ress

or

effi

cien

cy

New compressor

Conventional compressor

Load factor* Graph shown above is for illustration purposes only.

The back pressure control mecha-nism increases the efficiency during low-load operation.

Intermediate pressure adjustment port

The pressure on the orbiting scroll is optimised according to operating conditions. As a result, the orbiting scroll has been stabilised to increase efficiency during low-load operation.* For the classification of indoor units (VRT smart control and VRT control), refer to the indoor unit lineup.

• Refrigerant leakage is minimized by a back pressure control mechanism that increases the efficiency during low-load operation.

Fully Automatic Energy-saving Refrigerant Control

VRT Smart Control VRT Smart Control Function movie

New ScrollCompressormovie

Software technology New Scroll CompressorHardware technology

Calculate• Indoor airflow rate• Target refrigerant temperature

Determine the target refrigerant temperature

Room temperature and set temperature

Compressor speed control

Coordinated control

17 18

VRV X Series

VR

V X

Ser

ies

I-demand functionPeak power cut-off can be accomplished according to each user situation.

* Set on the PCB of the outdoor unit.

Standby power needed for preheating refrigerator oil was reduced up to 65.4% to save energy when the air conditioner is stopped.

Advanced Technologies

Advanced oil temperature control

High external static pressureVRV X series outdoor unit has been achieved high external static pressure up to 78.4 Pa.

Higher efficiency is provided during rated operation

VRV IV VRV X SERIES

Cooling operation conditions : Indoor temperature of 27°CDB 19°CWB, and outdoor temperature of 35°CDB.

4.32

4.65

4.07

4.45

3.80

4.29

3.74

4.23

3.46

3.95

3.25

3.91

3.11

3.78

Co

olin

g o

per

atio

n E

ER

8 HP6 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP0

3

4

5

4.41

4.95

EER at 100% operation load

* Operation calculation conditions: VRV X series 14 HP Location: Singapore Operation time: 08:00–18:00 on weekdays

Extended operation range up to 49°C

49°C20 30 4010

VRV X Series

Cooling Outdoor temperature (°CDB)

Contribute to optimised operation efficiency, higher quality and easier installation.

This function prevents a capacity shortage or energy loss due to excessive or insufficient refrigerant.

The automatic refrigerant charge function automates the charging of the proper refrigerant amount and the closing of shut-off valves by simply pressing a switch after pre-charging.

• Automatic completion by proper refrigerant amount• Monitoring refrigerant charging is unnecessary• No recalculation of charge amounts due to minor design changes locally

Automatic refrigerant charge function

Optimised operation efficiency

Higher quality and easier installation

Calculation of necessary refrigerant amount from design drawing

1 Pre-charge of refrigerant2 Start of automatic refrigerant charge operation

3

Optimised Operation

Efficiency Cooling capacity

Optimal refrigerantamount

Refrigerant charge amount

Insufficientrefrigerant charge

Excessiverefrigerant charge

Automatic Refrigerant Charge

R-410A

Can be set in

5% increments

Total of 11 levels

Pow

er c

onsu

mpt

ion

Less

Mor

e

* There are conditions in the range of ambient temperature in which the automatic refrigerant charge can be used. Refer to the installation manual for details. * The refrigerant amount that can be automatically charged may differ from the additional refrigerant amount that is provided from calculations, but there are no problems in performance and quality.

Automatic RefrigerantCharge Functionmovie

Note: When outdoor temperature falls below 10°C, the thermostat shuts OFF, the outdoor unit stops, and operation switches from cooling to fan operation.

* When set to 70% demand

100%

70%

50%40%

0%Time

65.4%Reduction

19 20

VRV X Series

VR

V X

Ser

ies

Comfort & ReliabilityComfort

Reliable and stable technology

Nighttime quiet operation function

High reliability at high ambient temperature

PCB

Power Module

RefrigerantRefrigerant JacketHeat

Refrigerant

Using refrigerant to cool the inverter power module helps minimise the size of the electronic components, and this results in reduction of airflow resistance and high efficiency of the heat exchanger.

*1. Initial setting is 8 hours. Can be selected from 6, 8 and 10 hours.*2. Initial setting is 9 hours. Can be selected from 8, 9 and 10 hours.*3. In case of 10 HP outdoor unit.

This enables

Control board failure ratio at stable operation is reduced.

• Suitability for high ambient temperatures

• Miniaturization of electronic components

Peak in the outdoortemperature

8 hrs*1 10 hrs*2

8:00 12:00 16:00 20:00 0:00 4:00 8:00

50%

100%

Night mode ENDSNight mode STARTS

Night quiet mode

Min. 40 dB(A)*3

40 dB(A)

56 dB(A)

Load %

Operating sound dB(A)The nighttime quiet operation function automatically suppresses the nighttime operating sound by reducing operation capacity to maintain the quiet environ-ment of the neighborhood. Three selectable modes are available depending on the required level.

Notes: • This function is available in setting at site.• The operating sound in quiet operation mode is the actual

value measured by our company. • The relationship of outdoor temperature (load) and time

shown above is just an example.

Outer rotor DC motor (ODM)

Only Daikin has adapted an ODM with the feature of stable rotation and volumetric efficiency.

Ease of maintenance

Can provide maintenance feature* without shutting down the whole VRV system.

Double backup operation functions

UNIQUEODM(Outer Type)Conventional Motor(Inner Type)

F

Rotor

F

Rotor

Function of information display by luminous digital tube

VRV X series utilises a bright 7-segment digital display to convey operational status and facilitate simple installation and after-sales service.

7-segment digital display

Displays system operation information directly

SMT* packaging technology

• Improves the anti-clutter performance.• Protects your computer boards from the adverse

effects of sandy climates and humid weather.

*SMT: Surface mounted technology

SMT packaging material

Computer control board

Computer control board surface adopting SMT packaging technology

* For single outdoor unit system RXUQ14-20AYM models. On-site settings are required using the PCB of the outdoor unit.

Malfunction

Malfunction

Emergencyoperation

Emergencyoperation

Automatic sequencing operation

Stage 3

Priority

Automaticsequencing

132

Stage 2

Priority

Automaticsequencing

HIGH TORQUEwith low energy

MORE efficient

213

Stage 1

Priority 321

* Field setting is required. This feature does not apply to residential indoor unit connection. For more information, please contact Daikin sales office.

Unit backup operation function Compressor backup operation function

Area CArea BArea A

21 22

VRV X Series

VR

V X

Ser

ies

The long piping length provides more design flexibility, which can match even large-sized buildings.

Flexible System Design

Long piping length

Connection capacity at maximum is 200%.

Connection ratio

More options for installation location

Installation for VRV indoor units only

Max. 90 m

Between the first indoor branch and the farthest indoor unit

Max. level difference between the indoor units

90 m

Max. level difference between the outdoor units and the indoor units

30 m

Note: The above is just a schematic diagram.

Max. equivalent piping length

190 m

165 m

Max. actual piping length

Max. 13 m1000 mMax. total piping length

Conditions of VRV indoor unit connection capacity

Single outdoor units

Double outdoor units

Triple outdoor units

Applicable VRV indoor units

FXB(P)Q

200%

Other VRV indoorunit models*1

200%160%130%

Connection ratio =Total capacity index of the indoor units

Capacity index of the outdoor units

*1. No special requirements up to 40 m. The maximum actual piping length can be 90 m, depending on conditions. The VRV X series is easy to extend to 90 m by lessening the conditions from conventional VRV IV models. Be sure to refer to the Engineering Data Book for details of these conditions and requirements.

*2. When level differences are 50 m or more, the diameter of the main liquid piping size must be increased. If the outdoor unit is above the indoor unit, a dedicated setting on the outdoor unit is required. Refer to the Engineering Data Book and contact your local dealer for more information.

Maximum allowable level difference

Maximum allowable piping length

Between the outdoor units and the indoor units

Between the indoor units

Between the outdoor units (Multiple use)

Between the first indoor branch and the farthest indoor unit

Between the outdoor branch and the last outdoor unit (Equivalent)

Total piping length

Actual piping length (Equivalent)

30 m

5 m

165 m (190 m)

1000 m

10 m (13 m)

90 m*2

90 m*1

*1 For the FXF(S)Q25, FXPQ and FXVQ models, maximum connection ratio is 130% for the entire range of outdoor units.

Note: If the operational capacity of indoor units is more than 130%, low airflow operation is enforced in all the indoor units.

*Refer to page 25 for outdoor unit combination details.

50%–200%

Connection ratio

Between the outdoor branchand the last outdoor unit

*2

*1

Max. 5 m

Between the outdoor units

FXDQ

FXSQ

FXMQ-PA

FXAQ

Installation for mixed combination of VRV and residential indoor units

Max. total piping length 250 m

Max. equivalent piping length

120 m

Max. actual piping length

100 m

Between the first indoor branch and the farthest VRV indoor unit

Max. level difference between the indoor units

15 m

15 m Max. level difference between the outdoor unit and the indoor unit

50 m

5 m

Note: The above is just a schematic diagram.

BP unit

RA

RA

RA

RA

VRV

BP unit

Max. 15 m

Between BP unit and indoor unitMax. level difference between the

outdoor unit and the BP units

40 m

Max. level difference between BP unit

Max. level difference between the BP unit and the indoor unit

VRV: VRV indoor unit RA: Residential indoor unit

Max. 50 m

Maximum allowablepiping length

Minimum allowable piping length

Maximum allowablelevel difference

Between the outdoor unitand the indoor unit

Between BP unit and indoor unit

Between the indoor units

Between BP units

Between the first indoor branch and the farthest BP unit or between the first indoor branch and the farthest VRV indoor unit

Total piping length

Actual piping length (Equivalent)

Between outdoor unit and the first indoor branch

15 m

15 m

100 m (120 m)

250 m

2 m–15 m

2 m–8 m

50 m*1

5 m

50 mIf the outdoor unit is above.

If the outdoor unit is below.

If indoor unit capacity index < 60.

If indoor unit capacity index is 60 and 71.

40 m

40 m

*1. If the piping length between the first indoor branch and BP unit or VRV indoor unit is over 20 m, it is necessary to increase the gas and liquid piping size between the first indoor branch and BP unit or VRV indoor unit. If the piping diameter of the sized up piping exceeds the diameter of the piping before the first indoor branch kit, then the latter also requires a liquid piping and gas piping size up. Please refer to Engineering Data Book for details.

*When a mixed combination of VRV and residential indoor units is connected or when only residential indoor units are connected, connection ratio must be 50% to 130%. Refer to page 25 for outdoor unit combination details. Between the outdoor unit and the BP unit

5 mBetween the BP unit and the indoor unit

*1

When a mixed combination of VRV and residential indoor units is connected

23 24

VRV X Series

VR

V X

Ser

ies

Achieves both anti-corrosion and high efficiency

High performance technology

New aluminum fins are 21% thicker to maintain performance.

Automated fin coating line

To prevent differences in coating thickness caused by manual application, the additional fin coatings are performed on the latest automated assembly line, maintaining high precision and quality.

Anti-corrosion Technology

Outer casing

Heat exchanger (Fin)

Maximize anti-corrosion and performance

Heavy anti-corrosion model

Multi coating for extreme durability

The hot-dip Zinc-Aluminum-Magnesium alloy coated sheet is optimised for even greater durability with an additional four-layer coating combination.

Anti-corrosion verification by accelerated test

Although the previous anti-corrosion model is rusted, the VRV X MAX outer casing shows no signs of corrosion in either test.

* The cross cut was made in order to simulate a severe case of coating damage and corrosion (not from regular usage).

Anti-corrosion technology

The aluminum fins on VRV X MAX are manufactured with thicker anti-corrosion layer including an additional two-layer coating.

Previous model Previous model

CASS TestSalt Spray Test CASS Test

CASS Test

: Corrosion : Corrosion: No corrosion : No corrosion

Hot-dip zinc-aluminum-magnesium alloy coated steel sheet

Primer base coating

Powder middle coating

Top coat metallic special coating

Top clear special coating

Aluminium fin High corrosion resistance aluminium fin

Primer base coating*

Corrosion resistance coating*

4-layer coating

: Corrosion : No corrosion

* outside area only

VRV X MAX

VRV X MAX

VRV X MAX

Standard model

RXUQ6-20AYMWRXUQ12-60AM(1)YMW

Built for

Seaside

Maximize lifespan

Specifications of anti-corrosion model

The new model resists corrosion by salt, maintains performance, and greatly reduces life cycle costs.

Hot-dip zinc-aluminum-magnesium alloy-coated steel sheet + Primer base coating + Powder middle coating + Top coat metallic special coating (metallic brown) + Top clear special coating

Item

1

Aluminum fin + High corrosion resistance aluminum fin + Primer base coating (outside area only) + Corrosion resistance coating (outside area only)

5

6

Fan motor stand • Electric box • Inner casing sheet metal 7

Hot rolled sheet steel + Double rust inhibitor coating with additional touch-up paint9

Low Density Polyethylene (LDPE) coatingDischarge grille • Protection net2

Resin fan + resin casing motor Fan • Fan motor8

SWCH + zinc-nickel plating SUS410 + zinc-nickel platingFasteners3

Copper tube + Standard aluminum fin Copper tube + Anti-corrosion aluminum finHeat exchanger4

Both side resin coating Expanded both side resin coatingPrinted circuit board10

Parts Standard model

Built for seaside

Must be installed at least 300 m away from the sea in a location not in direct contact with sea wind.

Must be installed where the unit does not get into contact with seawater.

Previous model: Anti-corrosion

300 - 1,000 m 0 – 1,000 m

outdoor unit

Building

outdoor unit

Sea

Sea windSea wind

Building

Sea

•Total life cycle cost

Time

Standard model

Replacement

Corrosio

n

period

Corrosion

period

Initial cost

0 – 1000m

: Heavy Anti-corrosion

Can be installed right by the sea

Sheet metal casing Outer casing Hot dip zinc coated sheet + powder coating

Aluminum fin Aluminum fin + Hydrophilic anti-corrosion

Heat exchanger end plate Hot-dip zinc-aluminum-magnesium alloy-coated steel sheet without coating

Pressure vessel (oil separator) Hot rolled sheet steel + painting

Hot dip zinc coated sheet + corrosion resistance polyurethane coating

Hot dip zinc coated sheet + corrosion resistance polyurethane coatingGalvanized iron sheet

A third party tested the corrosion resistance (ISO 9227: salt spray tests) of the reinforced fins and casing for ISO 12944: 2018 Category C5 and confirmed them to be at very high (VH) levels.ISO 12944-6:2018 : Paints and varnishes – Corrosion protection

of steel structures by protective paint systemsCategory C5 : Industrial areas with high humidity and

aggressive atmosphere and coastal areas with high salinity

Level VH : Very high (equivalent to an expected life of 25 years *)

ISO 9227

* This number of years is not the warranty period of the product.Product life depends on installation location and operating conditions.

: Corrosion test in artificial atmospheres-Salt spray tests

25 26

VRV X Series

VR

V X

Ser

ies

Outdoor unit combinations

The outdoor unit capacity is up to 60 HP (168 kW) in increments of 2 HP.

Outdoor Unit Lineup

For connection of VRV indoor units only

VRV X Series

Notes: *1. For multiple connection, the outdoor unit multi connection piping kit (separately sold) is required.*2. Values inside brackets are based on connection of indoor units rated at maximum capacity, 200% for single outdoor units, 160% for double outdoor units, and 130%

for triple outdoor units. Refer to page 21 for notes on connection capacity of indoor units.

HP Combination

RXUQ8A

RXUQ10A

RXUQ12A

RXUQ14A

RXUQ16A

RXUQ18A

RXUQ20A

RXUQ10A + RXUQ12A

RXUQ12A × 2

RXUQ12A + RXUQ14A

RXUQ12A + RXUQ16A

RXUQ12A + RXUQ18A

RXUQ12A + RXUQ20A

RXUQ14A + RXUQ20A

100 to 260 (400)

125 to 325 (500)

150 to 390 (600)

175 to 455 (700)

200 to 520 (800)

225 to 585 (900)

250 to 650 (1,000)

275 to 715 (880)

300 to 780 (960)

325 to 845 (1,040)

350 to 910 (1,120)

375 to 975 (1,200)

400 to 1,040 (1,280)

425 to 1,105 (1,360)

Model name

RXUQ8A

RXUQ10A

RXUQ12A

RXUQ14A

RXUQ16A

RXUQ18A

RXUQ20A

RXUQ22AM

RXUQ24AM

RXUQ26AM

RXUQ28AM

RXUQ30AM

RXUQ32AM

RXUQ34AM

8

10

12

14

16

18

20

22

24

26

28

30

32

34

13 (20)

16 (25)

19 (30)

22 (35)

26 (40)

29 (45)

32 (50)

35 (44)

39 (48)

42 (52)

45 (56)

48 (60)

52 (64)

55 (64)

58 (64)

61 (64)

64 (64)

64 (64)

BHFP22P100

BHFP22P151

RXUQ16A + RXUQ20A 450 to 1,170 (1,440)RXUQ36AM36

Maximum number ofconnectable indoor units*2

Total capacity index of connectable indoor units*2

Outdoor unit multi connection piping kit*1

Capacityindex

200

250

300

350

400

450

500

550

600

650

700

750

800

850

900

22.4

RXUQ6A 75 to 195 (300)RXUQ6A6 9 (15)–15016.0

28.0

33.5

40.0

45.0

50.0

56.0

RXUQ6A × 3 225 to 585 (585)RXUQ18AM118 29 (29)45048.0

RXUQ6A × 2 + RXUQ8A 250 to 650 (650)RXUQ20AM120 32 (32)50054.4

RXUQ6A + RXUQ6A 150 to 390 (480)RXUQ12AM12 19 (24)30032.0

RXUQ6A + RXUQ8A 175 to 455 (560)RXUQ14AM14 22 (28)35038.4

RXUQ8A + RXUQ8A 200 to 520 (640)RXUQ16AM16 26 (32)40044.8

61.5

67.0

73.5

78.5

83.5

89.5

101

RXUQ18A + RXUQ20A 475 to 1,235 (1,520)RXUQ38AM38 950106

RXUQ20A × 2 500 to 1,300 (1,600)RXUQ40AM40 1,000112

RXUQ12A × 2 + RXUQ18A 525 to 1,365 (1,365)RXUQ42AM42 1,050117

RXUQ12A × 2 + RXUQ20A 550 to 1,430 (1,430)RXUQ44AM44 1,100123

RXUQ12A + RXUQ14A + RXUQ20A 575 to 1,495 (1,495)RXUQ46AM46 1,150130

RXUQ12A + RXUQ16A+ RXUQ20A 600 to 1,560 (1,560)RXUQ48AM48 1,200135

RXUQ12A + RXUQ18A + RXUQ20A 625 to 1,625 (1,625)RXUQ50AM50 1,250140

RXUQ12A + RXUQ20A × 2 650 to 1,690 (1,690)RXUQ52AM52 1,300146

RXUQ14A + RXUQ20A × 2 675 to 1,755 (1,755)RXUQ54AM54 1,350152

RXUQ16A + RXUQ20A × 2 700 to 1,820 (1,820)RXUQ56AM56 1,400157

RXUQ18A + RXUQ20A × 2 725 to 1,885 (1,885)RXUQ58AM58 1,450162

RXUQ20A × 3 750 to 1,950 (1,950)RXUQ60AM60 1,500168

kW

96.0

For mixed combination of VRV and residential indoor units

RXUQ8AYM(W)

RXUQ10AYM(W)

RXUQ12AYM(W)

RXUQ14AYM(W)

RXUQ16AYM(W)

RXUQ18AYM(W)

RXUQ20AYM(W)

22.4

28.0

33.5

40.0

45.0

50.0

56.0

8

10

12

14

16

18

20

200

250

300

350

400

450

500

200

250

300

350

400

450

500

100% 130%

Combination (%)*2

Total capacity index of connectable indoor units*2

260

325

390

455

520

585

650

13

16

19

22

26

29

32

Model name*1 kW HPCapacity

indexMaximum number of

connectable indoor units

100

RXUQ6AYM(W) 16.0 6 150 150 195 975

125

150

175

200

225

250

50%

BHFP22P151

BHFP22P100

RXUQ8A + RXUQ10A

RXUQ8A + RXUQ12A

225 to 585 (720)

250 to 650 (800)

RXUQ18AM

RXUQ20AM

18

20

29 (36)

32 (40)

450

500

50.4

55.9

Lineup

8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60HP 6

VRV XSERIES

Single outdoor units

Double outdoor units

Triple outdoor units

Notes: *1. Only single outdoor unit (RXUQ6-20AYM(W)) can be connected.*2. Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor unit.

27 28

VRV X Series

VR

V X

Ser

ies

Floo

r St

andi

ngCe

iling

Susp

ende

dC

ateg

ory

Cei

ling

Mou

nted

Cas

sett

eC

eilin

g C

once

aled

Duc

t

3D Airflow Duct with Sensing

Round Flow Cassette with Sensing

Round Flow Cassette

Compact Multi Flow Cassette

Double Flow Cassette

Single Flow Cassette

Indoor Unit Lineup

Note: BP units are necessary for residential indoor units. Only single outdoor unit (RXUQ6-20AYM(W)) can be connected.

25 35

25 35

2.5 3.5

50 60 71

50 60 71

5.0 6.0 7.1Rated Capacity (kW)Type Model Name

Capacity Index

Slim Ceiling Concealed Duct

Wall Mounted

FDKS-EAVMB(700 mm width type)

(900/1,100 mm width type)

Enhanced range of choices

Spot Air Conditioner

FXZQ-AVM

FXPQ-AVN

VRT

FDKS-C(A)VMB VRT

FTKJ-NVMVW VRT

FTKJ-NVMVS VRT

FTKS-DVM VRT

FTKS-BVMA VRT

FTKS-FVM VRT

Residential indoor units with connection to BP unitsVRV indoor units VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

Indoor units subject to VRT smart control

Indoor units subject to VRT control

FXDSQ-AVM

FXSQ-PAVE

Capacity Range

Capacity Index 20

0.8 HP

20

1.6 HP

40

2.5 HP

63

3.2 HP

80

3 HP

71

4 HP

100

5 HP

125

6 HP

140

8 HP

200

10 HP

250

2 HP1.25 HP

32

62.531.25

1 HP

25

Type Model Name

FXFSQ-AVM

Ceiling Suspended

Wall Mounted

Floor Standing

Concealed Floor Standing

4-Way Flow Ceiling Suspended

Outdoor-Air Processing Unit

FXVQ-NY1

FXVQ-NY16(high static pressure type)

Floor Standing Duct

FXDQ-SPV1

400

16 HP

500

20 HP

FXMQ-MFV1

Heat Reclaim Ventilator

Air Handling Unit

Heat Reclaim Ventilator with DX-Coil and Humidifier

VKM-GA(M)V1

VAM-GJVE

AHUR

Airflow rate 500-1000 m3/h

Airflow rate 150-2000 m3/h

Clean Room Air ConditionerFXBQ-PVE

FXBPQ-PVE

FXEQ-AV36

FXFQ-AVM

FXCQ-AVM

FXMQ-PAVE

FXMQ-PVM

FXHQ-AVM

FXUQ-AVEB

FXHQ-MAVE

FXAQ-AVM

FXLQ-MAVE

FXNQ-MAVE

FXDQ-PDVE(with drain pump)

FXDQ-PDVET(without drain pump)

FXDQ-NDVE(with drain pump)

FXDQ-NDVET(without drain pump)

(700 mm width type)

( )900/1,100 mmwidth type

6–120 HP

50

40 8071 100 125 140 200 25025 400 50050

VRV indoor units combine with residential indoor units, all in one system.

VRV indoor units only

VRV indoor units

BP unit

Residential indoor units

BP unit

Residential indoor units only

BP unit

VRV indoor unit only system

Residential indoor unit only system

Residential indoor unit and VRV indoor unit mix system

64Max.

indoor units

• If a system has indoor units subject to both VRT smart and VRT control, the system is operated under VRT control.• If a system has both outdoor-air processing air conditioners and outdoor-air processing type indoor units, VRT smart control and VRT control are disabled.

32Max.

indoor units

• BP units are necessary for residential indoor units. Only single outdoor unit (RXUQ6-20AYM(W)) can be connected.• If a system has only residential indoor units, the system is operated under VRT control.

32Max.

indoor units

• BP units are necessary for residential indoor units. Only single outdoor unit (RXUQ6-20AYM(W)) can be connected.• If a system has both residential indoor units and VRV indoor units, the system is operated under VRT control.

New lineup

Slim Duct (Standard)

Slim Duct (Compact)

Middle Static Pressure Duct

Middle-High Static Pressure Duct

High Static Pressure Duct

29 30

VRV X Series

VR

V X

Ser

ies

Outdoor Units

Specifications

268+297 297+297

11.7+11.7

MODEL RXUQ8AYM(W) RXUQ10AYM(W) RXUQ12AYM(W) RXUQ14AYM(W) RXUQ16AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ22AMYM(W) RXUQ24AMYM(W) RXUQ26AMYM(W)

Combination units

RXUQ10AYM(W) RXUQ12AYM(W) RXUQ12AYM(W)

RXUQ12AYM(W) RXUQ12AYM(W) RXUQ14AYM(W)

Power supply 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

Cooling capacityBtu/h 76,400 95,500 114,000 136,000 154,000 171,000 191,000 210,000 229,000 251,000

kW

kW

22.4 28.0 33.5 40.0 45.0 50.0 56.0 61.5 67.0 73.5

4.82 6.29 7.81 9.46 11.4 12.8 14.8 14.1 15.6 17.3

Hermetically sealed scroll type Hermetically sealed scroll type

Casing colour

Compressor

%

m3/min

kW

kW

kW

178 191 268 297 178+191178+191 191+191 191+218

Dimensions (H×W×D) mm 1,657×1,240×7651,657×930×765 (1,657×1,240×765)+(1,657×1,240×765)

Machine weight kg

Sound level dB(A) 56 58 59 6562 61 62

Operation range °CDB 10 to 49 10 to 49

RefrigerantType R-410A R-410A

Charge kg 6.6 8.3 8.5 9.7 11.79.8

RXUQ16AMYM(W)

RXUQ8AYM(W)

RXUQ8AYM(W)

153,000

44.8

9.64

6.6+6.6 6.4+6.4+6.4 6.4+6.4+6.6

59 5960 60

RXUQ14AMYM(W)

RXUQ6AYM(W)

RXUQ8AYM(W)

131,000

38.4

8.05

119+178

6.4+6.6

RXUQ12AMYM(W)

RXUQ6AYM(W)

RXUQ6AYM(W)

109,000

32.0

6.46

119+119

57 58

6.4+6.4

RXUQ18AM1YM(W) RXUQ20AM1YM(W)

RXUQ6AYM(W) RXUQ6AYM(W)

RXUQ6AYM(W) RXUQ6AYM(W)

164,000 186,000

48.0 54.4

9.69 11.3

(1,657×930×765)+(1,657×930×765)+(1,657×930×765)

RXUQ18AMYM(W) RXUQ20AMYM(W)

RXUQ8AYM(W) RXUQ8AYM(W)

RXUQ10AYM(W) RXUQ12AYM(W)

172,000 191,000

50.4 55.9

11.1 12.6

(1,657×930×765)+(1,657×1,240×765)

6.6+8.3

178+178

6.6+8.5

8-100 7-100

119+119+119 119+119+178

RXUQ6AYM(W) RXUQ8AYM(W)

8.3+8.5 8.5+8.5 8.5+9.7

Pipingconnections

Liquid mm 9.5 (Brazing) 12.7 (Brazing) 15.9 (Brazing) 19.1 (Brazing)

Gas mm

RXUQ6AYM(W)

— — — — — — —

— — — — — — — —

54,600

16.0

3.23

119

54

6.4

19.1 (Brazing) 22.2 (Brazing) 28.6 (Brazing) 34.9 (Brazing)

MODEL RXUQ32AMYM(W) RXUQ34AMYM(W) RXUQ36AMYM(W) RXUQ38AMYM(W) RXUQ40AMYM(W) RXUQ50AMYM(W) RXUQ52AMYM(W) RXUQ54AMYM(W) RXUQ56AMYM(W) RXUQ58AMYM(W) RXUQ60AMYM(W)

Combination units

RXUQ12AYM(W) RXUQ14AYM(W) RXUQ16AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ12AYM(W) RXUQ12AYM(W) RXUQ14AYM(W) RXUQ16AYM(W) RXUQ18AYM(W) RXUQ20AYM(W)

RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ18AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W)

RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W) RXUQ20AYM(W)

Power supply 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

Cooling capacityBtu/h 305,000 328,000 345,000 362,000 382,000 478,000 498,000 519,000 536,000 553,000 573,000

kW 89.5 96.0 101 106 112 140 146 152 157 162 168

%

22.6 24.3 26.2 27.6 29.6 35.4 37.4 39.1 41.0 42.4 44.4

Hermetically sealed scroll type Hermetically sealed scroll type

RXUQ48AMYM(W)

RXUQ12AYM(W)

RXUQ16AYM(W)

RXUQ20AYM(W)

461,000

135

34.0

RXUQ46AMYM(W)

RXUQ12AYM(W)

RXUQ14AYM(W)

RXUQ20AYM(W)

444,000

130

32.1

RXUQ44AMYM(W)

RXUQ12AYM(W)

RXUQ12AYM(W)

RXUQ20AYM(W)

420,000

123

30.4

RXUQ42AMYM(W)

RXUQ12AYM(W)

RXUQ12AYM(W)

RXUQ18AYM(W)

399,000

117

28.4

Casing colour

Power consumption

Capacity control

191+268 191+297 218+297

Dimensions (H×W×D) mm (1,657×1,240×765)+(1,657×1,240×765) (1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765)

Machine weight kg

191+268+297 191+297+297191+191+268 191+191+297 191+218+297 268+297+297 297+297+297218+297+297

Sound level dB(A) 66 6867 65 66 67 68 7069

Operation range °CDB 10 to 49 10 to 49

RefrigerantR-410A R-410A

Charge kg 8.5+11.7 9.7+11.7 9.8+11.7 8.5+8.5+11.7 8.5+9.7+11.7 8.5+9.8+11.7 9.8+11.7+11.79.7+11.7+11.78.5+11.7+11.7 11.7+11.7+11.7

Pipingconnections

Liquid mm 19.1 (Brazing) 19.1 (Brazing)

Gas mm 41.3 (Brazing) 34.9 (Brazing)

RXUQ28AMYM(W) RXUQ30AMYM(W)

RXUQ12AYM(W) RXUQ12AYM(W)

RXUQ16AYM(W) RXUQ18AYM(W)

268,000 285,000

78.5 83.5

19.2 20.6

191+218

6362

8.5+9.8

41.3 (Brazing)

Type

m3/min

Airflow rate

Airflow rate

Type

Motor output

Compressor

Type

Motor output

218

Power consumption

Capacity control

(1,657×930×765)+(1,657×930×765)

12.7 (Brazing) 15.9 (Brazing)

28.6 (Brazing)

23-100 19-100 13-100 12-100 11-100 9-100 7-100 11-100 10-100 9-100 8-100 7-100 6-100

2-1003-1004-1004-1005-100

(3.4×1)+(2.9×1) (3.4×1)+(3.9×1) (3.7×1)+(4.3×1) (4.9×1)+(4.2×1) (2.4×1)+(2.4×1) (2.4×1)+(3.4×1) (3.4×1)+(3.4×1) (3.4×1)+(4.2×1) (3.4×1)+(5.2×1) (4.2×1)+(5.2×1) (5.2×1)+(5.2×1)(2.4×1)+(2.4×1)+(2.4×1) (2.4×1)+(2.4×1)+(3.4×1) (5.2×1)+(3.4×1)+(2.9×1)2.4×1 3.4×1 4.2×1 5.2×1

(5.2×1)+(3.4×1)+(3.9×1) (5.2×1)+(3.7×1)+(4.3×1) (5.2×1)+(4.9×1)+(4.2×1) (3.4×1)+(2.9×1)+(4.9×1)+(4.2×1)

(3.4×1)+(3.9×1)+(4.9×1)+(4.2×1)

(3.7×1)+(4.3×1)+(4.9×1)+(4.2×1)

(4.9×1)+(4.2×1)+(4.9×1)+(4.2×1)

(5.2×1)+(5.2×1)+(3.7×1)+(4.3×1)

(5.2×1)+(5.2×1)+(4.9×1)+(4.2×1)

(5.2×1)+(3.4×1)+(2.9×1)+(4.9×1)+(4.2×1)

(5.2×1)+(3.4×1)+(3.9×1)+(4.9×1)+(4.2×1)

(5.2×1)+(3.7×1)+(4.3×1)+(4.9×1)+(4.2×1)

(5.2×1)+(4.9×1)+(4.2×1)+(4.9×1)+(4.2×1)

(3.4×1)+(2.9×1)+(4.9×1)+(4.2×1)+(4.9×1)+(4.2×1)

(3.4×1)+(3.9×1)+(4.9×1)+(4.2×1)+(4.9×1)+(4.2×1)

(3.7×1)+(4.3×1)+(4.9×1)+(4.2×1)+(4.9×1)+(4.2×1)

(4.9×1)+(4.2×1)+(4.9×1)+(4.2×1)+(4.9×1)+(4.2×1)

Ivory white (5Y7.5/1) (Metallic brown )

Ivory white (5Y7.5/1) (Metallic brown ) Ivory white (5Y7.5/1) (Metallic brown )

185 (195 )

215+275 (235+295 ) 215+291 (235+316 ) 275+291 (295+316 ) 291+291 (316+316 ) 215+215+291 (235+235+316 ) 215+275+291 (235+295+316 ) 215+291+291 (235+316+316 ) 275+291+291 (295+316+316 ) 291+291+291 (316+316+316 )

215 (235 ) 275 (295 ) 291 (316 ) 185+185 (195+195 ) 185+215 (195+235 ) 185+185+185 (195+195+195 ) 215+215 (235+235 ) 215+275 (235+295 )

Ivory white (5Y7.5/1) (Metallic brown )

1

1 1 1 1 1

1 1 1

1

1 1

1

1 1 1 1

1

1 1 1 1

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.When there is concern for noise to the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

Note: 1. Models with (W) are the outdoor units with anti-corrosion specifications. For details, refer to pages 23 - 24 for more information.

VRV X Series

Cooling Only

VR

V A

Ser

ies

VRV A Series

31 32

Daikin’s VRV A series raised the standard of energy efficiency.

Greater energy savings during low-load operation

Higher Energy Efficiency Ratio (EER) for 10 HP

The key to innovativeenergy savings

14%Lower

Annual powerconsumption

10% 20% 30% 40% 50% 60% 70% 80% 90% 100%0

Load factor for the rated capacity

Op

erat

ion

per

iod Load factor of 50% or less

accounts for 80% of annual

operation period.

* Simulation conditions:• Location: Bangkok, Thailand

• System: Outdoor unit (10 HP) x 1

Indoor unit (2 HP, Round Flow with Sensing type) x 5

• Operation time: 8:00-20:00 5 days/week

• Outdoor units: New model: RXQ10A (VRV A series)

Conventional model: RXQ10T (VRV IV)

* Cooling operation conditions: • Indoor temperature of 27ºCDB, 19ºCWB, and outdoor temperature of 35ºCDB.

0

3

4

5

6

7

8

9

30% 40% 90% 100%50% 60% 70% 80% Load

Co

olin

g O

per

atio

n E

ER 8.167.78 7.57

6.775.92

5.234.68

4.09

Conventional model New model

Increased efficiencyduring low-load operation.

* Data source• Number of properties connected to the Air

Conditioning Network Service System: 42 projects

• Number of outdoor unit systems: 535 systems

• Data collection period: 8:00-18:00, weekdays

(excluding public holidays), from July 2015 to June

2016 in office buildings in Singapore.

Saves Space and Delivers Excellent Performance

Single Outdoor units

RXQ6-20AYM(W)

Double Outdoor units

RXQ18-40AMYM(W)

Triple Outdoor units

RXQ42-60AMYM(W)

*(W): Heavy anti-corrosion model

6HP–60HP

Cooling Only

(16 kW) (168 kW)

33 34

VR

V A

Ser

ies

VRV A Series

Advanced Technologies

Back pressure control mechanism

Advanced technologies for greater energy savings

* For the classification of indoor units (VRT smart control and VRT control), refer to the indoor unit lineup.

Calculate• Indoor airflow rate• Target refrigerant temperature

Determine the target refrigerant temperature

Room temperature and set temperature

Compressor speed control

Optimally supply only for the needed capacity of indoor units

• Reduces compressor load and minimizes operation loss so it is energy saving• Controls capacity according to load to ensure a constant room temperature for greater comfort.

Coordinated control

New intermediate pressure mechanism

The pressure on the orbiting scroll is optimised according to operating conditions. As a result, the orbiting scroll has been stabilised to increase efficiency during low-load operation.

Intermediate pressure adjustment port

Refrigerant leakage is minimized during low-load operation

By uniting advanced software and hardware technologies for greater energy savings during actual operation and combining the technologies of VRV, VRT and VAV, we have attained both energy savings and comfortable air conditioning.

Co

mp

ress

or

effi

cien

cy

New compressor

Conventional compressor

Load factor* Graph shown above is for illustration purposes only.

The back pressure control mecha-nism increases the efficiency during low-load operation.

• Refrigerant leakage is minimized by a back pressure control mechanism that increases the efficiency during low-load operation.

Fully Automatic Energy-saving Refrigerant Control

VRT Smart Control VRT Smart Control Function movie

New ScrollCompressormovie

Software technology New Scroll CompressorHardware technology

* The new mechanism is used in RXQ10, 12, 14 and 20A models.

35 36

VR

V A

Ser

ies

VRV A Series

I-demand functionPeak power cut-off can be accomplished according to each user situation.

* Set on the PCB of the outdoor unit.

Standby power needed for preheating refrigerator oil was reduced up to 82.7% to save energy when the air conditioner is stopped.

Advanced Technologies

Advanced oil temperature control

* Operation calculation conditions: VRV A series 14 HP Location: Singapore Operation time: 08:00–18:00 on weekdays

Extended operation range up to 49°C

Contribute to optimised operation efficiency, higher quality and easier installation.

This function prevents a capacity shortage or energy loss due to excessive or insufficient refrigerant.

The automatic refrigerant charge function automates the charging of the proper refrigerant amount and the closing of shut-off valves by simply pressing a switch after pre-charging.

• Automatic completion by proper refrigerant amount• Monitoring refrigerant charging is unnecessary• No recalculation of charge amounts due to minor design changes locally

Automatic refrigerant charge function

Optimised operation efficiency

Higher quality and easier installation

Calculation of necessary refrigerant amount from design drawing

1 Pre-charge of refrigerant2 Start of automatic refrigerant charge operation

3

Automatic Refrigerant Charge

R-410A

* There are conditions in the range of ambient temperature in which the automatic refrigerant charge can be used. Refer to the installation manual for details. * The refrigerant amount that can be automatically charged may differ from the additional refrigerant amount that is provided from calculations, but there are no problems in performance and quality.

Automatic RefrigerantCharge Functionmovie

49°C20 30 4010

VRV A Series

Cooling Outdoor temperature (°CDB)

Can be set in

5% increments

Total of 11 levels

Pow

er c

onsu

mpt

ion

Less

Mor

e

* When set to 70% demand

100%

70%

50%40%

0%Time

Optimised Operation

Efficiency Cooling capacity

Optimal refrigerantamount

Refrigerant charge amount

Insufficientrefrigerant charge

Excessiverefrigerant charge

82.7%Reduction

Note: When outdoor temperature falls below 10°C, the thermostat shuts OFF, the outdoor unit stops, and operation switches from cooling to fan operation.

High external static pressureVRV A series outdoor unit has been achieved high external static pressure up to 78.4 Pa.

37 38

VR

V A

Ser

ies

VRV A Series

Comfort & ReliabilityComfort

Reliable and stable technologyHigh reliability at high ambient temperature

PCB

Power Module

RefrigerantRefrigerant JacketHeat

Refrigerant

Using refrigerant to cool the inverter power module helps minimise the size of the electronic components, and this results in reduction of airflow resistance and high efficiency of the heat exchanger.

Control board failure ratio at stable operation is reduced.

Nighttime quiet operation function

*1. Initial setting is 8 hours. Can be selected from 6, 8 and 10 hours.*2. Initial setting is 9 hours. Can be selected from 8, 9 and 10 hours.*3. In case of 10 HP outdoor unit.

Peak in the outdoortemperature

8 hrs*1 10 hrs*2

8:00 12:00 16:00 20:00 0:00 4:00 8:00

50%

100%

Night mode ENDSNight mode STARTS

Night quiet mode

Min. 40 dB(A)*3

40 dB(A)

57 dB(A)

Load %

Operating sound dB(A)The nighttime quiet operation function automatically suppresses the nighttime operating sound by reducing operation capacity to maintain the quiet environ-ment of the neighborhood. Three selectable modes are available depending on the required level.

Notes: • This function is available in setting at site.• The operating sound in quiet operation mode is the actual

value measured by our company. • The relationship of outdoor temperature (load) and time

shown above is just an example.

This enables

• Suitability for high ambient temperatures

• Miniaturization of electronic components

Area CArea BArea A

Ease of maintenance

Can provide maintenance feature* without shutting down the whole VRV system.

Function of information display by luminous digital tube

VRV A series utilises a bright 7-segment digital display to convey operational status and facilitate simple installation and after-sales service.

SMT* packaging technology

•Improves the anti-clutter performance.•Protects your computer boards from the adverse effects of sandy climates and humid weather.

* SMT: Surface mounted technology

Computer control board surface adopting SMT packaging technology

* For single outdoor unit system RXQ16-20AYM models. On-site settings are required using the PCB of the outdoor unit.

Malfunction

Malfunction

Emergencyoperation

Emergencyoperation

Automatic sequencing operation

Stage 3

Priority

Automaticsequencing

132

Stage 2

Priority

Automaticsequencing

213

Stage 1

Priority 321

* Field setting is required. This feature does not apply to residential indoor unit connection. For more information, please contact Daikin sales office.

Outer rotor DC motor (ODM)

Only Daikin has adapted an ODM with the feature of stable rotation and volumetric efficiency.

UNIQUEODM(Outer Type)Conventional Motor(Inner Type)

F

Rotor

F

RotorHIGH TORQUE

with low energy

MORE efficient

7-segment digital display

Displays system operation information directly

Double backup operation functions

SMT packaging material

Computer control board

Unit backup operation function Compressor backup operation function

39 40

VR

V A

Ser

ies

VRV A Series

The long piping length provides more design flexibility, which can match even large-sized buildings.

Flexible System Design

Long piping length

Connection capacity at maximum is 200%.

Connection ratio

Installation for mixed combination of VRV and residential indoor units

More options for installation location

Installation for VRV indoor units only

Max. 90 m

Between the first indoor branch and the farthest indoor unit

90 m

Max. level difference between the outdoor units and the indoor units

Note: The above is just a schematic diagram.

Max. equivalent piping length

190 m

165 m

Max. actual piping length

1000 mMax. total piping length

Conditions of VRV indoor unit connection capacity

Single outdoor units

Double outdoor units

Triple outdoor units

Applicable VRV indoor units

200%

Other VRV indoorunit models*1

200%160%130%

Connection ratio =Total capacity index of the indoor units

Capacity index of the outdoor units

* 1. No special requirements up to 40 m. The maximum actual piping length can be 90 m, depending on conditions. The VRV A series is easy to extend to 90 m by lessening the conditions from conventional VRV IV models. Be sure to refer to the Engineering Data Book for details of these conditions and requirements.

* 2. When level differences are 50 m or more, the diameter of the main liquid piping size must be increased. If the outdoor unit is above the indoor unit, a dedicated setting on the outdoor unit is required. Refer to the Engineering Data Book and contact your local dealer for more information.

Maximum allowable level difference

Maximum allowable piping length

Between the outdoor units and the indoor units

Between the indoor units

Between the outdoor units (Multiple use)

Between the first indoor branch and the farthest indoor unit

Between the outdoor branch and the last outdoor unit (Equivalent)

Total piping length

Actual piping length (Equivalent)

30 m

5 m

165 m (190 m)

1000 m

10 m (13 m)

90 m*2

90 m*1

*1 For the FXF(S)Q25, FXPQ and FXVQ models, maximum connection ratio is 130% for the entire range of outdoor units.

Note: If the operational capacity of indoor units is more than 130%, low airflow operation is enforced in all the indoor units.

*Refer to page 43 for outdoor unit combination details.

50%–200%

Connection ratio

*2

*1

Max. 5 m

Between the outdoor unitsMax. 13 m

Between the outdoor branchand the last outdoor unit

Max. level difference between the indoor units

30 m

FXB(P)QFXDQ

FXSQ

FXMQ-PA

FXAQ

Max. total piping length 250 m

Max. equivalent piping length

120 m

Max. actual piping length

100 m

Between the first indoor branch and the farthest VRV indoor unit

Max. level difference between the indoor units

15 m

15 m Max. level difference between the outdoor unit and the indoor unit

50 m

5 m

Note: The above is just a schematic diagram.

BP unit

RA

RA

RA

RA

VRV

BP unit

Max. 15 m

Between BP unit and indoor unitMax. level difference between the

outdoor unit and the BP units

40 m

Max. level difference between BP unit

Max. level difference between the BP unit and the indoor unit

VRV: VRV indoor unit RA: Residential indoor unit

Max. 50 m

Maximum allowablepiping length

Minimum allowable piping length

Maximum allowablelevel difference

Between the outdoor unitand the indoor unit

Between BP unit and indoor unit

Between the indoor units

Between BP units

Between the first indoor branch and the farthest BP unit or between the first indoor branch and the farthest VRV indoor unit

Total piping length

Actual piping length (Equivalent)

Between outdoor unit and the first indoor branch

15 m

15 m

100 m (120 m)

250 m

2 m–15 m

2 m–8 m

50 m*1

5 m

50 mIf the outdoor unit is above.

If the outdoor unit is below.

If indoor unit capacity index < 60.

If indoor unit capacity index is 60 and 71.

40 m

40 m

*1. If the piping length between the first indoor branch and BP unit or VRV indoor unit is over 20 m, it is necessary to increase the gas and liquid piping size between the first indoor branch and BP unit or VRV indoor unit. If the piping diameter of the sized up piping exceeds the diameter of the piping before the first indoor branch kit, then the latter also requires a liquid piping and gas piping size up. Please refer to Engineering Data Book for details.

*When a mixed combination of VRV and residential indoor units is connected or when only residential indoor units are connected, connection ratio must be 50% to 130%. Refer to page 43 for outdoor unit combination details. Between the outdoor unit and the BP unit

5 mBetween the BP unit and the indoor unit

*1

When a mixed combination of VRV and residential indoor units is connected

41 42

VR

V A

Ser

ies

VRV A Series

Achieves both anti-corrosion and high efficiency

High performance technology

New aluminum fins are 21% thicker to maintain performance.

Automated fin coating line

To prevent differences in coating thickness caused by manual application, the additional fin coatings are performed on the latest automated assembly line, maintaining high precision and quality.

Anti-corrosion Technology

Outer casing

Heat exchanger (Fin)

Maximize anti-corrosion and performance

Heavy anti-corrosion model

Multi coating for extreme durability

The hot-dip Zinc-Aluminum-Magnesium alloy coated sheet is optimised for even greater durability with an additional four-layer coating combination.

Anti-corrosion verification by accelerated test

Although the previous anti-corrosion model is rusted, the VRV A MAX outer casing shows no signs of corrosion in either test.

* The cross cut was made in order to simulate a severe case of coating damage and corrosion (not from regular usage).

Anti-corrosion technology

The aluminum fins on VRV A MAX are manufactured with thicker anti-corrosion layer including an additional two-layer coating.

Previous model Previous model

CASS TestSalt Spray Test CASS Test

CASS Test

: Corrosion : Corrosion: No corrosion : No corrosion

Hot-dip zinc-aluminum-magnesium alloy coated steel sheet

Primer base coating

Powder middle coating

Top coat metallic special coating

Top clear special coating

Aluminium fin High corrosion resistance aluminium fin

Primer base coating*

Corrosion resistance coating*

4-layer coating

: Corrosion : No corrosion

* outside area only

VRV A MAX

VRV A MAX

VRV A MAX

Standard model

RXQ6-20AYMWRXQ18-60AMYMW

Built for

Seaside

Maximize lifespan

Specifications of anti-corrosion model

The new model resists corrosion by salt, maintains performance, and greatly reduces life cycle costs.

Hot-dip zinc-aluminum-magnesium alloy-coated steel sheet + Primer base coating + Powder middle coating + Top coat metallic special coating (metallic brown) + Top clear special coating

Item

1

Aluminum fin + High corrosion resistance aluminum fin + Primer base coating (outside area only) + Corrosion resistance coating (outside area only)

5

6

Fan motor stand • Electric box • Inner casing sheet metal 7

Hot rolled sheet steel + Double rust inhibitor coating with additional touch-up paint9

Low Density Polyethylene (LDPE) coatingDischarge grille • Protection net2

Resin fan + resin casing motor Fan • Fan motor8

SWCH + zinc-nickel plating SUS410 + zinc-nickel platingFasteners3

Copper tube + Standard aluminum fin Copper tube + Anti-corrosion aluminum finHeat exchanger4

Both side resin coating Expanded both side resin coatingPrinted circuit board10

Parts Standard model

•Total life cycle cost

Time

Standard model

Replacement

Corrosio

n

period

Corrosion

period

Initial cost

Built for seaside

Must be installed at least 300 m away from the sea in a location not in direct contact with sea wind.

Must be installed where the unit does not get into contact with seawater.

300 - 1,000 m 0 – 1,000 m

outdoor unit

Building

outdoor unit

Sea

Sea windSea wind

Building

Sea0 – 1000m

Can be installed right by the sea

Previous model: Anti-corrosion : Heavy Anti-corrosion

Sheet metal casing Outer casing Hot dip zinc coated sheet + powder coating

Aluminum fin Aluminum fin + Hydrophilic anti-corrosion

Heat exchanger end plate Hot-dip zinc-aluminum-magnesium alloy-coated steel sheet without coating

Pressure vessel (oil separator) Hot rolled sheet steel + painting

Hot dip zinc coated sheet + corrosion resistance polyurethane coating

Hot dip zinc coated sheet + corrosion resistance polyurethane coatingGalvanized iron sheet

A third party tested the corrosion resistance (ISO 9227: salt spray tests) of the reinforced fins and casing for ISO 12944: 2018 Category C5 and confirmed them to be at very high (VH) levels.ISO 12944-6:2018 : Paints and varnishes – Corrosion protection

of steel structures by protective paint systemsCategory C5 : Industrial areas with high humidity and

aggressive atmosphere and coastal areas with high salinity

Level VH : Very high (equivalent to an expected life of 25 years *)

ISO 9227

* This number of years is not the warranty period of the product.Product life depends on installation location and operating conditions.

: Corrosion test in artificial atmospheres-Salt spray tests

43 44

VR

V A

Ser

ies

VRV A Series

Outdoor Unit Combinations

The outdoor unit capacity is up to 60 HP (168 kW) in increments of 2 HP.

Outdoor Unit Lineup

For connection of VRV indoor units only

VRV A Series

Notes: *1. For multiple connection, the outdoor unit multi connection piping kit (separately sold) is required.*2. Values inside brackets are based on connection of indoor units rated at maximum capacity, 200% for single outdoor units, 160% for double outdoor units,

and 130% for triple outdoor units. Refer to page 39 for notes on connection capacity of indoor units.

For mixed combination of VRV and residential indoor unitsLineup

8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60HP 6

VRV ASERIES

Single outdoor units

Double outdoor units

Triple outdoor units

Notes: *1. Only single outdoor unit (RXQ6-20AYM(W)) can be connected.*2. Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor unit.

RXQ6AYM(W)

RXQ8AYM(W)

RXQ10AYM(W)

RXQ12AYM(W)

RXQ14AYM(W)

RXQ16AYM(W)

RXQ18AYM(W)

RXQ20AYM(W)

16.0

22.4

28.0

33.5

40.0

45.0

50.0

56.0

6

8

10

12

14

16

18

20

150

200

250

300

350

400

450

500

150

200

250

300

350

400

450

500

195

260

325

390

455

520

585

650

100% 130%

Combination (%)*2

Total capacity index of connectable indoor units*2

9

13

16

19

22

26

29

32

Model name*1 kW HPCapacity

indexMaximum number of

connectable indoor units

75

100

125

150

175

200

225

250

50%

HP Combination

RXQ8A

RXQ10A

RXQ12A

RXQ14A

RXQ16A

RXQ18A

RXQ20A

RXQ8A + RXQ10A

RXQ8A + RXQ12A

RXQ10A + RXQ12A

RXQ12A × 2

RXQ12A + RXQ14A

RXQ12A + RXQ16A

RXQ12A + RXQ18A

RXQ14A + RXQ18A

RXQ16A + RXQ18A

100 to 260 (400)

125 to 325 (500)

150 to 390 (600)

175 to 455 (700)

200 to 520 (800)

225 to 585 (900)

250 to 650 (1,000)

225 to 585 (720)

250 to 650 (800)

275 to 715 (880)

300 to 780 (960)

325 to 845 (1,040)

350 to 910 (1,120)

375 to 975 (1,200)

400 to 1,040 (1,280)

425 to 1,105 (1,360)

Model name

RXQ8A

RXQ10A

RXQ12A

RXQ14A

RXQ16A

RXQ18A

RXQ20A

RXQ18AM

RXQ20AM

RXQ22AM

RXQ24AM

RXQ26AM

RXQ28AM

RXQ30AM

RXQ32AM

RXQ34AM

8

10

12

14

16

18

20

18

20

22

24

26

28

30

32

34

13 (20)

16 (25)

19 (30)

22 (35)

26 (40)

29 (45)

32 (50)

29 (36)

32 (40)

35 (44)

39 (48)

42 (52)

45 (56)

48 (60)

52 (64)

55 (64)

58 (64)

61 (64)

64 (64)

BHFP22P100

BHFP22P151

RXQ18A × 2 450 to 1,170 (1,440)RXQ36AM36

Maximum number ofconnectable indoor units*2

Total capacity index of connectable indoor units*2

Outdoor unit multi connection piping kit*1

Capacityindex

200

250

300

350

400

450

500

450

500

550

600

650

700

750

800

850

900

22.4

RXQ6A 75 to 195 (300)RXQ6A6 9 (15)–15016.0

28.0

33.5

40.0

45.0

50.0

56.0

50.4

55.9

61.5

67.0

73.5

78.5

83.5

90.0

100

RXQ18A + RXQ20A 475 to 1,235 (1,520)RXQ38AM38 950106

RXQ20A × 2 500 to 1,300 (1,600)RXQ40AM40 1,000112

RXQ12A × 2 + RXQ18A 525 to 1,365 (1,365)RXQ42AM42 1,050117

RXQ12A × 2 + RXQ20A 550 to 1,430 (1,430)RXQ44AM44 1,100123

RXQ14A × 2 + RXQ18A 575 to 1,495 (1,495)RXQ46AM46 1,150130

RXQ14A + RXQ16A + RXQ18A 600 to 1,560 (1,560)RXQ48AM48 1,200135

RXQ14A + RXQ18A × 2 625 to 1,625 (1,625)RXQ50AM50 1,250140

RXQ16A + RXQ18A × 2 650 to 1,690 (1,690)RXQ52AM52 1,300145

RXQ18A × 3 675 to 1,755 (1,755)RXQ54AM54 1,350150

RXQ18A × 2 + RXQ20A 700 to 1,820 (1,820)RXQ56AM56 1,400156

RXQ18A + RXQ20A × 2 725 to 1,885 (1,885)RXQ58AM58 1,450162

RXQ20A × 3 750 to 1,950 (1,950)RXQ60AM60 1,500168

kW

95.0

45 46

VR

V A

Ser

ies

VRV A SeriesFl

oor

Stan

ding

Ceilin

g Su

spen

ded

Cat

egor

yC

eilin

g M

ount

ed C

asse

tte

Cei

ling

Con

ceal

ed D

uct

Indoor Unit Lineup

Note: BP units are necessary for residential indoor units. Only single outdoor unit (RXQ6-20AYM(W)) can be connected.

25 35

25 35

2.5 3.5

50 60 71

50 60 71

5.0 6.0 7.1Rated Capacity (kW)Type Model Name

Capacity Index

Slim CeilingConcealed Duct

Wall Mounted

FDKS-EAVMB(700 mm width type)

(900/1,100 mm width type)

Enhanced range of choices

Spot Air Conditioner

FXZQ-AVM

FXPQ-AVN

VRT

FDKS-C(A)VMB VRT

FTKJ-NVMVW VRT

FTKJ-NVMVS VRT

FTKS-DVM VRT

FTKS-BVMA VRT

FTKS-FVM VRT

Residential indoor units with connection to BP unitsVRV indoor units VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

Indoor units subject to VRT smart control

Indoor units subject to VRT control

FXDSQ-AVM

FXSQ-PAVE

Capacity Range

Capacity Index 20

0.8 HP

20

1.6 HP

40

2.5 HP

63

3.2 HP

80

3 HP

71

4 HP

100

5 HP

125

6 HP

140

8 HP

200

10 HP

250

2 HP1.25 HP

32

62.531.25

1 HP

25

Type Model Name

FXFSQ-AVM

Ceiling Suspended

Wall Mounted

Floor Standing

Concealed Floor Standing

4-Way Flow Ceiling Suspended

Outdoor-Air Processing Unit

FXVQ-NY1

FXVQ-NY16(high static pressure type)

Floor Standing Duct

FXDQ-SPV1

400

16 HP

500

20 HP

FXMQ-MFV1

Heat Reclaim Ventilator

Air Handling Unit

Heat Reclaim Ventilator with DX-Coil and Humidifier

VKM-GA(M)V1

VAM-GJVE

AHUR

Airflow rate 500-1000 m3/h

Airflow rate 150-2000 m3/h

Clean Room Air ConditionerFXBQ-PVE

FXBPQ-PVE

FXEQ-AV36

FXFQ-AVM

FXCQ-AVM

FXMQ-PAVE

FXMQ-PVM

FXHQ-AVM

FXUQ-AVEB

FXHQ-MAVE

FXAQ-AVM

FXLQ-MAVE

FXNQ-MAVE

FXDQ-PDVE(with drain pump)

FXDQ-PDVET(without drain pump)

FXDQ-NDVE(with drain pump)

FXDQ-NDVET(without drain pump)

(700 mm width type)

( )900/1,100 mmwidth type

6–120 HP

50

40 8071 100 125 140 200 25025 400 50050

VRV indoor units combine with residential indoor units, all in one system.

VRV indoor units only

VRV indoor units

BP unit

Residential indoor units

BP unit

Residential indoor units only

BP unit

VRV indoor unit only system

Residential indoor unit only system

Residential indoor unit and VRV indoor unit mix system

64Max.

indoor units

• If a system has indoor units subject to both VRT smart and VRT control, the system is operated under VRT control.• If a system has both outdoor-air processing air conditioners and outdoor-air processing type indoor units, VRT smart control and VRT control are disabled.

32Max.

indoor units

• BP units are necessary for residential indoor units. Only single outdoor unit (RXQ6-20AYM(W)) can be connected.• If a system has only residential indoor units, the system is operated under VRT control.

32Max.

indoor units

• BP units are necessary for residential indoor units. Only single outdoor unit (RXQ6-20AYM(W)) can be connected.• If a system has both residential indoor units and VRV indoor units, the system is operated under VRT control.

New lineup

3D Airflow Duct with Sensing

Middle Static Pressure Duct

Round Flow Cassette with Sensing

Round Flow Cassette

Compact Multi Flow Cassette

Double Flow Cassette

Single Flow Cassette

Slim Duct (Standard)

Middle-High Static Pressure Duct

High Static Pressure Duct

Slim Duct (Compact)

47 48

VR

V A

Ser

ies

VRV A Series

Outdoor Units

Specifications

Airflow rate

MODEL RXQ6AYM(W) RXQ8AYM(W) RXQ10AYM(W) RXQ12AYM(W) RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ18AMYM(W) RXQ20AMYM(W) RXQ22AMYM(W) RXQ24AMYM(W) RXQ26AMYM(W) RXQ28AMYM(W) RXQ30AMYM(W)

Combination units— — — — — — — — RXQ8AYM(W) RXQ8AYM(W) RXQ10AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ12AYM(W)

— — — — — — — — RXQ10AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W)

Power supply 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

Cooling capacityBtu/h 54,600 76,400 95,500 114,000 136,000 154,000 171,000 191,000 172,000 191,000 210,000 229,000 251,000 268,000 285,000

kW 16.0 22.4 28.0 33.5 40.0 45.0 50.0 56.0 50.4 55.9 61.5 67.0 73.5 78.5 83.5

kW

%

kW

3.38 5.17 6.84 8.70 10.7 12.9 15.3

25-100

2.3×1

20-100 13-100 12-100 11-100 10-100 10-100

3.4×1 4.5×1 5.6×1 6.4×1 (3.5×1)+(3.5×1) (4.0×1)+(4.0×1)

17.7 12.0 13.9 15.5 17.4 19.4 21.6 24.0

7-100 7-100 7-100 6-100 6-100 6-100 5-100 5-100

(3.8×1)+(6.3×1) (3.4×1)+(4.5×1) (3.4×1)+(5.6×1) (4.5×1)+(5.6×1) (5.6×1)+(5.6×1) (5.6×1)+(6.4×1)(5.6×1)+(3.5×1)+(3.5×1)

(5.6×1)+(4.0×1)+(4.0×1)

Casing colour

Compressor

Power consumption

Capacity control

m3/min 119 191 257 297 178+178 178+191 191+191 191+257

Dimensions (H×W×D ) mm 1,657×930×765 1,657×1,240×765 1,657×1,240×765 (1,657×930×765)+(1,657×930×765) (1,657×930×765)+(1,657×1,240×765)

Machine weight kg 175 (180 ) 185 (195 ) 215 (235 ) 260 (280 ) 285 (310 ) 175+185 (180+195 ) 185+185 (195+195 ) 185+215 (195+235 ) 185+260 (195+280 )

Sound level dB(A) 56 57 59 60 61 65 60 61 62 63

Operation range °CDB 10 to 49 10 to 49

RefrigerantType

Type

Motor output

R-410A R-410A

Charge kg 5.9 6.7 6.8 7.4 8.2 8.4 11.8 5.9+6.7 5.9+6.8 6.7+6.8 6.8+6.8 6.8+7.4 6.8+8.2 6.8+8.4

Piping connections

Liquid mm 9.5 (Brazing) 12.7 (Brazing) 15.9 (Brazing) 15.9 (Brazing) 19.1 (Brazing)

Gas mm 19.1 (Brazing) 22.2 (Brazing) 28.6 (Brazing) 28.6 (Brazing) 34.9 (Brazing)

Ivory white (5Y7.5/1) (Metallic brown )

Hermetically sealed scroll type

Ivory white (5Y7.5/1) (Metallic brown )

Hermetically sealed scroll type

178

MODEL RXQ32AMYM(W) RXQ34AMYM(W) RXQ36AMYM(W) RXQ38AMYM(W) RXQ40AMYM(W) RXQ42AMYM(W) RXQ44AMYM(W) RXQ46AMYM(W) RXQ48AMYM(W) RXQ50AMYM(W) RXQ52AMYM(W) RXQ54AMYM(W) RXQ56AMYM(W) RXQ58AMYM(W) RXQ60AMYM(W)

Combination units

RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ14AYM(W) RXQ14AYM(W) RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W)

RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ20AYM(W) RXQ12AYM(W) RXQ12AYM(W) RXQ14AYM(W) RXQ16AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ20AYM(W)

— — — — — RXQ18AYM(W) RXQ20AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ18AYM(W) RXQ20AYM(W) RXQ20AYM(W) RXQ20AYM(W)

Power supply 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

Cooling capacityBtu/h 307,000 324,000 341,000 362,000 382,000 399,000 420,000 444,000 461,000 478,000 495,000 512,000 532,000 553,000 573,000

kW 90.0 95.0 100 106 112 117 123 130 135 140 145 150 156 162 168

kW

%

26.0 28.2 30.6 33.0 35.4 32.7 35.1

5-100 5-100 5-100 4-100 3-100 4-100 3-100

36.7 38.9 41.3

3-100 3-100 3-100

43.5 45.9 48.3 50.7 53.1

3-100 3-100 3-100 2-100 2-100

Casing colour

Power consumption

Capacity control

257+257 297+297257+297 191+191+257 191+191+297 257+257+257 257+257+297 257+297+297 297+297+297

Dimensions (H×W×D) mm (1,657×1,240×765)+(1,657×1,240×765)(1,657×930×765)+(1,657×930×765)+

(1,657×1,240×765)(1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765)

Machine weight kg 215+260 (235+280 ) 260+260 (280+280 ) 260+285 (280+310 ) 285+285 (310+310 ) 185+185+260 (195+195+280 ) 185+185+285 (195+195+310 ) 215+215+260 (235+235+280 ) 215+260+260 (235+280+280 ) 260+260+260 (280+280+280 ) 260+260+285 (280+280+310 ) 260+285+285 (280+310+310 ) 285+285+285 (310+310+310 )

Sound level dB(A) 64 66 68 65 67 65 66 68 69 70

Operation range °CDB 10 to 49 10 to 49

RefrigerantType R-410A R-410A

Charge kg 7.4+8.4 8.2+8.4 8.4+8.4 8.4+11.8 11.8+11.8 6.8+6.8+8.4 6.8+6.8+11.8 7.4+7.4+8.4 7.4+8.2+8.4 7.4+8.4+8.4 8.2+8.4+8.4 8.4+8.4+8.4 8.4+8.4+11.8 8.4+11.8+11.8 11.8+11.8+11.8

Piping connections

Liquid mm 19.1 (Brazing) 19.1 (Brazing)

Gas mm 34.9 (Brazing) 41.3 (Brazing) 41.3 (Brazing)

m3/minAirflow rate

Ivory white (5Y7.5/1) (Metallic brown )

Hermetically sealed scroll type

Ivory white (5Y7.5/1) (Metallic brown )

Hermetically sealed scroll type

kWCompressor

Type

Motor output(6.4×1)+(4.0×1)+(4.0×1)

(3.5×1)+(3.5×1)+(4.0×1)+(4.0×1)

(4.0×1)+(4.0×1)+(4.0×1)+(4.0×1)

(4.0×1)+(4.0×1)+(3.8×1)+(6.3×1)

(3.8×1)+(6.3×1)+(3.8×1)+(6.3×1)

(5.6×1)+(5.6×1)+(4.0×1)+(4.0×1)

(5.6×1)+(5.6×1)+(3.8×1)+(6.3×1)

(6.4×1)+(6.4×1)+(4.0×1)+(4.0×1)

(6.4×1)+(3.5×1)+(3.5×1)+(4.0×1)+(4.0×1)

(6.4×1)+(4.0×1)+(4.0×1)+(4.0×1)+(4.0×1)

(3.5×1)+(3.5×1)+(4.0×1)+(4.0×1)+(4.0×1)+(4.0×1)

(4.0×1)+(4.0×1)+(4.0×1)+(4.0×1)+(4.0×1)+(4.0×1)(4.0×1)+(4.0×1)+(4.0×1)+(4.0×1)+(4.0×1)+(4.0×1)

(4.0×1)+(4.0×1)+(4.0×1)+(4.0×1)+(3.8×1)+(6.3×1)

(4.0×1)+(4.0×1)+(3.8×1)+(6.3×1)+(3.8×1)+(6.3×1)

(3.8×1)+(6.3×1)+(3.8×1)+(6.3×1)+(3.8×1)+(6.3×1)

1

1 1 1 1 1 1 1 1 1

1

1 1

1 1 1 1 1 1 1 1 1 1 1 1

Notes: Specifications are based on the following conditions;•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.When there is concern for noise to the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

Note: 1. Models with (W) are the outdoor units with anti-corrosion specifications. For details, refer to pages 41 - 42 for more information.

Cooling Only

VRV A Series

VR

V H

Ser

ies

VRV H Series

49 50

Daikin’s VRV H series raised the standard of energy efficiency.

Greater energy savings during low-load operation

Higher Energy Efficiency Ratio (EER) for 10 HP

The key to innovativeenergy savings

14%Lower

Annual powerconsumption

10% 20% 30% 40% 50% 60% 70% 80% 90% 100%0

Load factor for the rated capacity

Op

erat

ion

per

iod Load factor of 50% or less

accounts for 80% of annual

operation period.

* Simulation conditions:• Location: Bangkok, Thailand

• System: Outdoor unit (10 HP) x 1

Indoor unit (2 HP, Round Flow with Sensing type) x 5

• Operation time: 8:00-20:00 5 days/week

• Outdoor units: New model: RXYQ10A (VRV H series)

Conventional model: RXYQ10T (VRV IV)

* Cooling operation conditions: • Indoor temperature of 27ºCDB, 19ºCWB, and outdoor temperature of 35ºCDB.

0

3

4

5

6

7

8

9

30% 40% 90% 100%50% 60% 70% 80% Load

Co

olin

g O

per

atio

n E

ER 8.167.78 7.57

6.775.92

5.234.68

4.09

Conventional model New model

Increased efficiencyduring low-load operation.

* Data source• Number of properties connected to the Air

Conditioning Network Service System: 42 projects

• Number of outdoor unit systems: 535 systems

• Data collection period: 8:00-18:00, weekdays

(excluding public holidays), from July 2015 to June

2016 in office buildings in Singapore.

Provides Highly-Efficient, Comfortable Cooling and Heating

Double outdoor units

RXYQ12-16AHYMV

Triple outdoor units

RXYQ18-44AHYMV

Single outdoor units

RXYQ6-20AYM

Double outdoor units

RXYQ22-40AYMV

Triple outdoor units

RXYQ42-60AYMV

High-COP Type Standard Type

6HP–60HP

Heat Pump

(16 kW) (168 kW)

51 52

VR

V H

Ser

ies

VRV H Series

* For the classification of indoor units (VRT smart control and VRT control), refer to the indoor unit lineup.

* The new mechanism is used in RXYQ10, 12 and 20A models.

Calculate• Indoor airflow rate• Target refrigerant temperature

Determine the target refrigerant temperature

Room temperature and set temperature

Compressor speed control

Coordinated control

New intermediate pressure mechanism

Back pressure control mechanism

Intermediate pressure adjustment port

The pressure on the orbiting scroll is optimised according to operating conditions. As a result, the orbiting scroll has been stabilised to increase efficiency during low-load operation.

Advanced TechnologiesAdvanced technologies for greater energy savings

Refrigerant leakage is minimized during low-load operationOptimally supply only for the needed capacity of indoor units• Reduces compressor load and minimizes operation loss so it is energy saving• Controls capacity according to load to ensure a constant room temperature for greater comfort.

By uniting advanced software and hardware technologies for greater energy savings during actual operation and combining the technologies of VRV, VRT and VAV, we have attained both energy savings and comfortable air conditioning.

Co

mp

ress

or

effi

cien

cy

New compressor

Conventional compressor

Load factor* Graph shown above is for illustration purposes only.

The back pressure control mecha-nism increases the efficiency during low-load operation.

• Refrigerant leakage is minimized by a back pressure control mechanism that increases the efficiency during low-load operation.

Fully Automatic Energy-saving Refrigerant Control

VRT Smart Control VRT Smart Control Function movie

New ScrollCompressormovie

Software technology New Scroll CompressorHardware technology

53 54

VR

V H

Ser

ies

VRV H Series

I-demand functionPeak power cut-off can be accomplished according to each user situation.

*Set on the PCB of the outdoor unit.

Standby power needed for preheating refrigerator oil was reduced up to 82.7% to save energy when the air conditioner is stopped.

Advanced Technologies

Advanced oil temperature control

*Operation calculation conditions: VRV H series 14 HP Location: SingaporeOperation time: 08:00–18:00 on weekdays

Extended operation range up to 49°C

Contribute to optimised operation efficiency, higher quality and easier installation.

This function prevents a capacity shortage or energy loss due to excessive or insufficient refrigerant.

The automatic refrigerant charge function automates the charging of the proper refrigerant amount and the closing of shut-off valves by simply pressing a switch after pre-charging.

• Automatic completion by proper refrigerant amount• Monitoring refrigerant charging is unnecessary• No recalculation of charge amounts due to minor design changes locally

Automatic refrigerant charge function

Optimised operation efficiency

Higher quality and easier installation

Calculation of necessary refrigerant amount from design drawing

1 Pre-charge of refrigerant2 Start of automatic refrigerant charge operation

3

Automatic Refrigerant Charge

R-410A

*There are conditions in the range of ambient temperature in which the automatic refrigerant charge can be used. Refer to the installation manual for details. *The refrigerant amount that can be automatically charged may differ from the additional refrigerant amount that is provided from calculations, but there are no problems in performance and quality.

Automatic RefrigerantCharge Functionmovie

Can be set in

5% increments

Total of 11 levels

Pow

er c

onsu

mpt

ion

Less

Mor

e

* When set to 70% demand

100%

70%

50%40%

0%Time

82.7%Reduction

High external static pressureVRV H series outdoor unit has been achieved high external static pressure up to 78.4 Pa.

Optimised Operation

Efficiency Cooling capacity

Optimal refrigerantamount

Refrigerant charge amount

Insufficientrefrigerant charge

Excessiverefrigerant charge

49°CDB0 10 20-20 -10 30 40

-5°CDB-5°CDB

-20°CWB 15.5°CWB15.5°CWB

Cooling

Heating

Outdoor temperature (°CDB)

55 56

VR

V H

Ser

ies

VRV H Series

Comfort & ReliabilityComfort

UNIQUE

F

Rotor

Function of information display by luminous digital tube

VRV H series utilises a bright 7-segment digital display to convey operational status and facilitate simple installation and after-sales service.

7-segment digital display

Displays system operation information directly

*SMT: Surface mounted technology

Computer control board surface adopting SMT packaging technology

*For single outdoor unit system RXYQ14-20AYM models. On-site settings are required using the PCB of the outdoor unit.

Malfunction

Malfunction

Emergencyoperation

Emergencyoperation

Stage 3

Priority

Automaticsequencing

132

Stage 2

Priority

Automaticsequencing

213

Stage 1

Priority 321

Peak in the outdoortemperature

8 hrs*1 10 hrs*2

8:00 12:00 16:00 20:00 0:00 4:00 8:00

50%

100%

Night mode ENDSNight mode STARTS

Night quiet mode

Min. 40 dB(A)*3

40 dB(A)

57 dB(A)

Load %

Operating sound dB(A)

Nighttime quiet operation function

The nighttime quiet operation function automatically suppresses the nighttime operating sound by reducing operation capacity to maintain the quiet environ-ment of the neighborhood. Three selectable modes are available depending on the required level.

Notes: • This function is available in setting at site.• The operating sound in quiet operation mode is the actual

value measured by our company. • The relationship of outdoor temperature (load) and time

shown above is just an example.

*1. Initial setting is 8 hours. Can be selected from 6, 8 and 10 hours.*2. Initial setting is 9 hours. Can be selected from 8, 9 and 10 hours.*3. In case of 10 HP outdoor unit.

Reliable and stable technologyHigh reliability at high ambient temperature

PCB

Power Module

RefrigerantRefrigerant JacketHeat

Refrigerant

Using refrigerant to cool the inverter power module helps minimise the size of the electronic components, and this results in reduction of airflow resistance and high efficiency of the heat exchanger.

Control board failure ratio at stable operation is reduced.

Outer rotor DC motor (ODM)

Only Daikin has adapted an ODM with the feature of stable rotation and volumetric efficiency.

Double backup operation functions

ODM(Outer Type)Conventional Motor(Inner Type)

F

Rotor

SMT* packaging technology

• Improves the anti-clutter performance.• Protects your computer boards from the adverse

effects of sandy climates and humid weather.

*SMT: Surface mounted technology

SMT packaging material

Computer control board

Automatic sequencing operation

HIGH TORQUEwith low energy

MORE efficient

Unit backup operation function Compressor backup operation function

This enables

• Suitability for high ambient temperatures

• Miniaturization of electronic components

Ease of maintenance

Can provide maintenance feature* without shutting down the whole VRV system.

*Field setting is required. This feature does not apply to residential indoor unit connection. For more information, please contact Daikin sales office. Area CArea BArea A

57 58

VR

V H

Ser

ies

VRV H Series

The long piping length provides more design flexibility, which can match even large-sized buildings.

Flexible System Design

Long piping length

Connection capacity at maximum is 200%.

Connection ratio

More options for installation location

Installation for VRV indoor units only

Max. 90 m

Between the first indoor branch and the farthest indoor unit

90 m

Max. level difference between the outdoor units and the indoor units

Note: The above is just a schematic diagram.

1000 mMax. total piping length

Conditions of VRV indoor unit connection capacity

Single outdoor units

Double outdoor units

Triple outdoor units

Applicable VRV indoor units

200%

Other VRV indoorunit models*1

200%160%130%

Connection ratio =Total capacity index of the indoor units

Capacity index of the outdoor units

* 1. No special requirements up to 40 m. The maximum actual piping length can be 90 m, depending on conditions. The VRV H series is easy to extend to 90 m by lessening the conditions from conventional VRV IV models. Be sure to refer to the Engineering Data Book for details of these conditions and requirements.

* 2. When level differences are 50 m or more, the diameter of the main liquid piping size must be increased. If the outdoor unit is above the indoor unit, a dedicated setting on the outdoor unit is required. Refer to the Engineering Data Book and contact your local dealer for more information.

Maximum allowable level difference

Maximum allowable piping length

Between the outdoor units and the indoor units

Between the indoor units

Between the outdoor units (Multiple use)

Between the first indoor branch and the farthest indoor unit

Between the outdoor branch and the last outdoor unit (Equivalent)

Total piping length

Actual piping length (Equivalent)

30 m

5 m

165 m (190 m)

1000 m

10 m (13 m)

90 m*2

90 m*1

*1 For the FXF(S)Q25, FXPQ and FXVQ models, maximum connection ratio is 130% for the entire range of outdoor units.

Note: If the operational capacity of indoor units is more than 130%, low airflow operation is enforced in all the indoor units.

*Refer to page 59 for outdoor unit combination details.

50%–200%

Connection ratio

*2

*1

Max. 5 m

Between the outdoor unitsMax. 13 m

Between the outdoor branchand the last outdoor unit

Max. level difference between the indoor units

30 m

FXB(P)QFXDQ

FXSQ

FXMQ-PA

FXAQ

Max. equivalent piping length

190 m

165 m

Max. actual piping length

Installation for mixed combination of VRV and residential indoor units

Max. total piping length 250 m

Max. equivalent piping length

120 m

Between the first indoor branch and the farthest VRV indoor unit

Max. level difference between the indoor units

15 m

15 m Max. level difference between the outdoor unit and the indoor unit

50 m

5 m

Note: The above is just a schematic diagram.

BP unit

RA

RA

RA

RA

VRV

BP unit

Max. 15 m

Between BP unit and indoor unitMax. level difference between the

outdoor unit and the BP units

40 m

Max. level difference between BP unit

Max. level difference between the BP unit and the indoor unit

VRV: VRV indoor unit RA: Residential indoor unit

Max. 50 m

Maximum allowablepiping length

Minimum allowable piping length

Maximum allowablelevel difference

Between the outdoor unitand the indoor unit

Between BP unit and indoor unit

Between the indoor units

Between BP units

Between the first indoor branch and the farthest BP unit or between the first indoor branch and the farthest VRV indoor unit

Total piping length

Actual piping length (Equivalent)

Between outdoor unit and the first indoor branch

15 m

15 m

100 m (120 m)

250 m

2 m–15 m

2 m–8 m

50 m*1

5 m

50 mIf the outdoor unit is above.

If the outdoor unit is below.

If indoor unit capacity index < 60.

If indoor unit capacity index is 71.

2 m–12 mIf indoor unit capacity index is 60.

40 m

40 m

*1. If the piping length between the first indoor branch and BP unit or VRV indoor unit is over 20 m, it is necessary to increase the gas and liquid piping size between the first indoor branch and BP unit or VRV indoor unit. If the piping diameter of the sized up piping exceeds the diameter of the piping before the first indoor branch kit, then the latter also requires a liquid piping and gas piping size up. Please refer to Engineering Data Book for details.

*When a mixed combination of VRV and residential indoor units is connected or when only residential indoor units are connected, connection ratio must be 80% to 130%. Refer to page 59 for outdoor unit combination details.

Between the outdoor unit and the BP unit

5 mBetween the BP unit and the indoor unit

*1

When a mixed combination of VRV and residential indoor units is connected

59 60

VR

V H

Ser

ies

VRV H Series

Outdoor unit combinations

The outdoor unit capacity is up to 60 HP (168 kW) in increments of 2 HP.

Outdoor Unit Lineup

For connection of VRV indoor units only

VRV H Series

Lineup

8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60HP 6

VRV HSERIES

High-COP Type

Standard Type

For mixed combination of VRV and residential indoor units

Notes: *1. Only single outdoor unit (RXYQ6-20AYM) can be connected.*2. Total capacity index of connectable indoor units must be 80%–130% of the capacity index of the outdoor unit.

16.0

22.4

28.0

33.5

40.0

45.0

50.0

56.0

6

8

10

12

14

16

18

20

150

200

250

300

350

400

450

500

150

200

250

300

350

400

450

500

195

260

325

390

455

520

585

650

130%

9

13

16

19

22

26

29

32

Model name*1 kW HP Capacityindex

Maximum number ofconnectable indoor units

120

160

200

240

280

320

360

400

80% 100%

Combination (%)

Total capacity index of connectable indoor units*2

RXYQ6AYM

RXYQ8AYM

RXYQ10AYM

RXYQ12AYM

RXYQ14AYM

RXYQ16AYM

RXYQ18AYM

RXYQ20AYM

Notes: *1. For multiple connection, the outdoor unit multi connection piping kit (separately sold) is required.*2. Values inside brackets are based on connection of indoor units rated at maximum capacity, 200% for single outdoor units, 160% for double outdoor units, and 130%

for triple outdoor units. Refer to page 57 for notes on connection capacity of indoor units.

HP Combination

RXYQ8A

RXYQ10A

RXYQ12A

RXYQ14A

RXYQ16A

RXYQ18A

RXYQ20A

RXYQ10A + RXYQ12A

RXYQ12A × 2

RXYQ12A + RXYQ14A

RXYQ12A + RXYQ16A

RXYQ12A + RXYQ18A

RXYQ16A × 2

RXYQ16A + RXYQ18A

Model name

RXYQ8A

RXYQ10A

RXYQ12A

RXYQ14A

RXYQ16A

RXYQ18A

RXYQ20A

RXYQ22A

RXYQ24A

RXYQ26A

RXYQ28A

RXYQ30A

RXYQ32A

RXYQ34A

8

10

12

14

16

18

20

22

24

26

28

30

32

34

RXYQ16A + RXYQ20ARXYQ36A36

Maximum number ofconnectable indoor units*2

Total capacity index of connectable indoor units*2

Outdoor unit multi connection piping kit*1

Capacityindex

22.4

RXYQ6ARXYQ6A6 16.0

28.0

33.5

40.0

45.0

50.0

56.0

61.5

67.0

73.5

78.5

83.5

90.0

101

RXYQ18A + RXYQ20ARXYQ38A38 106

RXYQ20A × 2RXYQ40A40 112

RXYQ12A × 2 + RXYQ18ARXYQ42A42 117

RXYQ12A × 2 + RXYQ20ARXYQ44A44 123

RXYQ14A + RXYQ16A × 2RXYQ46A46 130

RXYQ16A × 3RXYQ48A48 135

RXYQ16A × 2 + RXYQ18ARXYQ50A50 140

RXYQ16A + RXYQ18A × 2

100 to 260 (400)

125 to 325 (500)

150 to 390 (600)

175 to 455 (700)

200 to 520 (800)

225 to 585 (900)

250 to 650 (1,000)

275 to 715 (880)

300 to 780 (960)

325 to 845 (1,040)

350 to 910 (1,120)

375 to 975 (1,200)

400 to 1,040 (1,280)

425 to 1,105 (1,360)

13 (20)

16 (25)

19 (30)

22 (35)

26 (40)

29 (45)

32 (50)

35 (44)

39 (48)

42 (52)

45 (56)

48 (60)

52 (64)

55 (64)

58 (64)

61 (64)

64 (64)

BHFP22P100

BHFP22P151

450 to 1,170 (1,440)

75 to 195 (300) 9 (15)–

475 to 1,235 (1,520)

500 to 1,300 (1,600)

525 to 1,365 (1,365)

550 to 1,430 (1,430)

575 to 1,495 (1,495)

600 to 1,560 (1,560)

625 to 1,625 (1,625)

650 to 1,690 (1,690)

675 to 1,755 (1,755)

700 to 1,820 (1,820)

725 to 1,885 (1,885)

750 to 1,950 (1,950)

RXYQ52A52

200

250

300

350

400

450

500

550

600

650

700

750

800

850

900

150

950

1,000

1,050

1,100

1,150

1,200

1,250

1,300

1,350

1,400

1,450

1,500

145

kW

95.0

Standard Type

RXYQ18A × 3RXYQ54A54 150

RXYQ18A × 2 + RXYQ20ARXYQ56A56 156

RXYQ18A + RXYQ20A × 2RXYQ58A58 162

RXYQ20A × 3RXYQ60A60 168

HP Combination

RXYQ6A × 2

RXYQ6A + RXYQ8A

RXYQ8A × 2

RXYQ6A × 3

RXYQ6A × 2 + RXYQ8A

RXYQ6A + RXYQ8A × 2

RXYQ8A × 3

RXYQ8A × 2 + RXYQ10A

RXYQ8A × 2 + RXYQ12A

RXYQ8A + RXYQ10A + RXYQ12A

RXYQ8A + RXYQ12A × 2

RXYQ10A + RXYQ12A × 2

Model name

RXYQ12AH

RXYQ14AH

RXYQ16AH

RXYQ18AH

RXYQ20AH

RXYQ22AH

RXYQ24AH

RXYQ26AH

RXYQ28AH

RXYQ30AH

RXYQ32AH

RXYQ34AH

12

14

16

18

20

22

24

26

28

30

32

34

Maximum number ofconnectable indoor units*2

Total capacity index of connectable indoor units*2

Outdoor unit multi connection piping kit*1

Capacityindex

32.0

38.4

44.8

48.0

54.4

60.8

67.2

72.8

78.3

83.9

89.4

kW

95.0

150 to 390 (480)

175 to 455 (560)

200 to 520 (640)

225 to 585 (585)

250 to 650 (650)

275 to 715 (715)

300 to 780 (780)

325 to 845 (845)

350 to 910 (910)

375 to 975 (975)

400 to 1,040 (1,040)

425 to 1,105 (1,105)

19 (24)

22 (28)

26 (32)

29 (29)

32 (32)

35 (35)

39 (39)

42 (42)

45 (45)

48 (48)

52 (52)

55 (55)

450 to 1,170 (1,170)

475 to 1,235 (1,235)

500 to 1,300 (1,300)

525 to 1,365 (1,365)

550 to 1,430 (1,430)

58 (58)

61 (61)

64 (64)

BHFP22P151

BHFP22P100

300

350

400

450

500

550

600

650

700

750

800

850

900

950

1,000

1,050

1,100

High-COP Type

RXYQ12A × 3RXYQ36AH36 101

RXYQ12A × 2 + RXYQ14ARXYQ38AH38 107

RXYQ12A × 2 + RXYQ16ARXYQ40AH40 112

RXYQ10A + RXYQ16A × 2RXYQ42AH42 118

RXYQ12A + RXYQ16A × 2RXYQ44AH44 124

61 62

VR

V H

Ser

ies

VRV H SeriesFl

oor

Stan

ding

Ceilin

g Su

spen

ded

Cat

egor

yC

eilin

g M

ount

ed C

asse

tte

Cei

ling

Con

ceal

ed D

uct

Indoor Unit Lineup

Note: BP units are necessary for residential indoor units. Only single outdoor unit (RXYQ6-20AYM) can be connected.

20

20

2.0

25 35

25 35

2.5 3.5

50 60 71

50 60 71

5.0 6.0 7.1Rated Capacity (kW)Type Model Name

Capacity Index

Slim CeilingConcealed Duct

Wall Mounted

CDXS-EAVMA(700 mm width type)

(900/1,100 mm width type)

Enhanced range of choices

Spot Air Conditioner

FXZQ-AVM

FXPQ-AVN

VRT

FDXS-CVMA VRT

FTXJ-NVMVW VRT

FTXJ-NVMVS VRT

FTXS-DVMA

FTXS-EVMAVRT

FTXS-FVMA VRT

Residential indoor units with connection to BP unitsVRV indoor units VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

Indoor units subject to VRT smart control

Indoor units subject to VRT control

FXDSQ-AVM

FXSQ-PAVE

Capacity Range

Capacity Index 20

0.8 HP

20

1.6 HP

40

2.5 HP

63

3.2 HP

80

3 HP

71

4 HP

100

5 HP

125

6 HP

140

8 HP

200

10 HP

250

2 HP1.25 HP

32

62.531.25

1 HP

25

Type Model Name

FXFSQ-AVM

Ceiling Suspended

Wall Mounted

Floor Standing

Concealed Floor Standing

4-Way Flow Ceiling Suspended

Outdoor-Air Processing Unit

FXVQ-NY1

FXVQ-NY16(high static pressure type)

Floor Standing Duct

FXDQ-SPV1

400

16 HP

500

20 HP

FXMQ-MFV1

Heat Reclaim Ventilator

Air Handling Unit

Heat Reclaim Ventilator with DX-Coil and Humidifier

VKM-GA(M)V1

VAM-GJVE

AHUR

Airflow rate 500-1000 m3/h

Airflow rate 150-2000 m3/h

Clean Room Air ConditionerFXBQ-PVE

FXBPQ-PVE

FXEQ-AV36

FXFQ-AVM

FXCQ-AVM

FXMQ-PAVE

FXMQ-PVM

FXHQ-AVM

FXUQ-AVEB

FXHQ-MAVE

FXAQ-AVM

FXLQ-MAVE

FXNQ-MAVE

FXDQ-PDVE(with drain pump)

FXDQ-PDVET(without drain pump)

FXDQ-NDVE(with drain pump)

FXDQ-NDVET(without drain pump)

(700 mm width type)

( )900/1,100 mmwidth type

6–120 HP

50

40 8071 100 125 140 200 25025 400 50050

VRV indoor units combine with residential indoor units, all in one system.

VRV indoor units only

VRV indoor units

BP unit

Residential indoor units

BP unit

Residential indoor units only

BP unit

VRV indoor unit only system

Residential indoor unit only system

Residential indoor unit and VRV indoor unit mix system

64Max.

indoor units

• If a system has indoor units subject to both VRT smart and VRT control, the system is operated under VRT control.• If a system has both outdoor-air processing air conditioners and outdoor-air processing type indoor units, VRT smart control and VRT control are disabled.

32Max.

indoor units

• BP units are necessary for residential indoor units. Only single outdoor unit (RXYQ6-20AYM) can be connected.• If a system has only residential indoor units, the system is operated under VRT control.

32Max.

indoor units

• BP units are necessary for residential indoor units. Only single outdoor unit (RXYQ6-20AYM) can be connected.• If a system has both residential indoor units and VRV indoor units, the system is operated under VRT control.

New lineup

3D Airflow Duct with Sensing

Middle Static Pressure Duct

Round Flow Cassette with Sensing

Round Flow Cassette

Compact Multi Flow Cassette

Double Flow Cassette

Single Flow Cassette

Slim Duct (Standard)

Middle-High Static Pressure Duct

High Static Pressure Duct

Slim Duct (Compact)

63 64

VR

V H

Ser

ies

VRV H Series

Outdoor Units

Specifications

High-COP Type

Model

Combination units

Power supply

Cooling capacity

Heating capacity

Power consumption

Casing colour

Airflow rate

Dimensions (H×W×D)

Machine weight

Sound level

Operation range

RefrigerantType

Cooling

Cooling

Heating

Heating

Charge

Piping connections

Liquid

Gas

Btu/h

Btu/h

kW

kW

kW

kW

m3/min

mm

kg

dB(A)

°CWB

°CDB

kg

mm

mm

Model

Combination units

Power supply

Cooling capacity

Heating capacity

Power consumption

Casing colour

Airflow rate

Dimensions (H×W×D)

Machine weight

Sound level

Operation range

RefrigerantType

Cooling

Heating

Cooling

Heating

Charge

Piping connections

Liquid

Gas

Btu/h

Btu/h

kW

kW

kW

kW

m3/min

mm

kg

dB(A)

°CDB

°CWB

kg

mm

mm

RXYQ12AHYMV

RXYQ6AYM

RXYQ6AYM

109,000

32.0

123,000

36.0

6.76

7.46

131,000

38.4

147,000

43.0

8.55

9.40

153,000

44.8

171,000

50.0

10.3

11.3

Ivory white (5Y7.5/1)

178+178

-20 to 15.5

R-410A

-20 to 15.5

-5 to 49 -5 to 49

R-410A

28.6 (Brazing)

119+119+178119+119+119 119+178+178 178+178+178 178+178+191

(1,657×930×765)+(1,657×930×765)+(1,657×930×765)

119+178

185+185

6.9+7.06.9+6.9 7.0+7.0

12.7 (Brazing)

185+185+185

61

185+200+200185+185+200185+185+185

61

7.0+7.0+7.06.9+7.0+7.0

15.9 (Brazing)

7.0+7.0+7.4 7.0+7.0+7.6

19.1 (Brazing)

28.6 (Brazing) 34.9 (Brazing)

7.0+7.4+7.6

62

6.9+6.9+6.9 6.9+6.9+7.0

15.9 (Brazing)

(1,657×930×765)+(1,657×930×765) (1,657×930×765)+(1,657×930×765)+(1,657×930×765)

119+119

59

Ivory white (5Y7.5/1)

164,000

48.0

184,000

54.0

10.1

11.2

186,000

54.4

208,000

61.0

11.9

13.1

RXYQ14AHYMV

RXYQ6AYM

RXYQ8AYM

RXYQ16AHYMV

RXYQ8AYM

RXYQ8AYM

RXYQ18AHYMV

RXYQ6AYM

RXYQ6AYM

RXYQ6AYM

RXYQ20AHYMV

RXYQ6AYM

RXYQ6AYM

RXYQ8AYM

RXYQ22AHYMV

RXYQ6AYM

RXYQ8AYM

RXYQ8AYM

RXYQ24AHYMV

RXYQ8AYM

RXYQ8AYM

RXYQ8AYM

RXYQ26AHYMV

RXYQ8AYM

RXYQ8AYM

RXYQ10AYM

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

RXYQ32AHYMV

RXYQ8AYM

RXYQ12AYM

RXYQ12AYM

RXYQ34AHYMV

RXYQ10AYM

RXYQ12AYM

RXYQ12AYM

RXYQ36AHYMV

RXYQ12AYM

RXYQ12AYM

RXYQ12AYM

RXYQ38AHYMV

RXYQ12AYM

RXYQ12AYM

RXYQ14AYM

RXYQ40AHYMV

RXYQ12AYM

RXYQ12AYM

RXYQ16AYM

RXYQ42AHYMV

RXYQ10AYM

RXYQ16AYM

RXYQ16AYM

RXYQ44AHYMV

RXYQ12AYM

RXYQ16AYM

RXYQ16AYM

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

Ivory white (5Y7.5/1)

178+257+257 191+257+257191+191+257191+191+191

(1,657×930×765)+(1,657×930×765)+(1,657×930×765) (1,657×930×765)+(1,657×930×765)+(1,657×1,240×765)

178+191+191

200+200+200 200+200+285185+200+200

6463

(1,657×930×765)+(1,657×1,240×765)+(1,657×1,240×765)

200+285+285

64

-5 to 49

R-410A

-5 to 49

-20 to 15.5 -20 to 15.5

R-410A

19.1 (Brazing) 19.1 (Brazing)

Ivory white (5Y7.5/1)

Hermetically sealed scroll type Hermetically sealed scroll type

Hermetically sealed scroll typeHermetically sealed scroll type

RXYQ28AHYMV

RXYQ8AYM

RXYQ8AYM

RXYQ12AYM

RXYQ30AHYMV

RXYQ8AYM

RXYQ10AYM

RXYQ12AYM

207,000 229,000 248,000 267,000 286,000

60.8 67.2 72.8 78.3 83.9

232,000 256,000 278,000 299,000 321,000

68.0 75.0 81.5 87.5 94.0

13.7 15.5 17.2 19.0 20.7

15.1 17.0

403,000 423,000

118 124

450,000 471,000

132 138

32.6 34.5

32.4

382,000

112

427,000

125

30.3

30.4

365,000

107

409,000

120

28.1

28.8

345,000

101

386,000

113

26.1

26.7

324,000

95.0

365,000

107

24.2

25.1

305,000

89.4

341,000

100

22.6

23.5 34.1

7.4+9.3+9.37.6+7.6+9.37.6+7.6+9.17.6+7.6+7.67.4+7.6+7.67.0+7.6+7.6 7.6+9.3+9.3

34.9 (Brazing) 41.3 (Brazing) 41.3 (Brazing)

18.6 20.3 21.8

12-100 11-100 10-100 8-100 7-100

3-1004-1005-100

(4.5×1)+(3.6×1)+(3.7×1)(3.6×1)+(3.7×1)

(5.5×1)+(5.5×1)+(3.6×1)+(3.7×1)

(5.5×1)+(5.5×1)+(2.9×1)+(3.3×1)

(5.5×1)+(5.5×1)+(5.5×1)(4.5×1)+(5.5×1)+(5.5×1)(3.4×1)+(5.5×1)+(5.5×1) (5.5×1)+(3.6×1)+(3.7×1)(3.6×1)+(3.7×1)

5-100

(2.4×1)+(2.4×1) (2.4×1)+(3.4×1) (3.4×1)+(3.4×1) (2.4×1)+(2.4×1)+(2.4×1) (2.4×1)+(2.4×1)+(3.4×1) (2.4×1)+(3.4×1)+(3.4×1) (3.4×1)+(3.4×1)+(3.4×1) (3.4×1)+(3.4×1)+(4.5×1) (3.4×1)+(3.4×1)+(5.5×1) (3.4×1)+(4.5×1)+(5.5×1)kW

%

CompressorType

Motor output

Capacity control

Capacity control

kW

%

Compressor

Type

Motor output

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5

m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m,

Level difference: 0 m.• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit

at a height of 1.5 m.During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

VRV H Series

Heat Pump

65 66

VR

V H

Ser

ies

VRV H Series

Outdoor Units

Specifications

Standard Type

Model

Combination units

Power supply

Cooling capacity

Heating capacity

Power consumption

Casing colour

Airflow rate

Dimensions (H×W×D)

Machine weight

Sound level

Operation range

RefrigerantType

Cooling

Cooling

Heating

Heating

Charge

Piping connections

Liquid

Gas

Btu/h

Btu/h

kW

kW

kW

kW

m3/min

mm

kg

dB(A)

°CDB

°CWB

kg

mm

mm

Model

Combination units

Power supply

Cooling capacity

Heating capacity

Power consumption

Casing colour

Airflow rate

Dimensions (H×W×D)

Machine weight

Sound level

Operation range

RefrigerantType

Cooling

Cooling

Heating

Heating

Charge

Piping connections

Liquid

Gas

Btu/h

Btu/h

kW

kW

kW

kW

m3/min

mm

dB(A)

°CWB

°CDB

kg

kg

mm

mm

RXYQ6AYM

— — — —

RXYQ8AYM RXYQ10AYM RXYQ12AYM RXYQ14AYM RXYQ16AYM RXYQ20AYM RXYQ22AYMV RXYQ24AYMV RXYQ26AYMV RXYQ28AYMV RXYQ30AYMV

RXYQ10AYM RXYQ12AYM RXYQ12AYM RXYQ12AYM RXYQ12AYM

RXYQ12AYM RXYQ12AYM RXYQ14AYM RXYQ16AYM RXYQ18AYM

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

Ivory white (5Y7.5/1) Ivory white (5Y7.5/1)

25-100 20-100 13-100 12-100 11-100 10-100 10-100

Hermetically sealed scroll type

2.4×1 3.4×1 4.5×1 5.5×1 (2.9×1)+(3.3×1) (3.6×1)+(3.7×1)

Hermetically sealed scroll type

54,600 76,400 95,500 114,000 136,000 154,000 191,000 210,000 229,000 251,000 268,000 285,000

16.0 22.4 28.0 33.5 40.0 45.0

215,000 235,000 256,000 281,000 299,000 319,000

63.0 69.0 75.0 82.5 87.5 93.5

17.7 15.5 17.4 19.4 21.6 24.0

17.1 16.1 17.8 19.9 21.5 23.8

61,400 85,300 107,000 128,000 154,000 171,000

18.0 25.0 31.5 37.5 45.0 50.0

3.38 5.17 6.84 8.70 10.7 12.9

3.73 5.67 7.23 8.91 11.0 12.6

56.0 61.5 67.0 73.5 78.5 83.5

324,000 345,000 362,000 382,000 399,000 420,000 444,000 461,000 478,000 495,000 512,000 532,000 553,000 573,000

95.0 101 106 112 117 123 130 135 140 145 150 156 162 168

495,000 512,000 532,000 553,000 573,000 597,000 621,000 645,000

145 150 156 162 168 175 182 189

36.5 38.7 41.1 43.5 45.9 48.3 50.7 53.1

36.2 37.8 40.1 42.4 44.7 46.9 49.1 51.3

362,000 386,000 406,000 430,000 447,000 471,000

106 113 119 126 131 138

28.2 30.6 33.0 35.4 32.7 35.1

27.5 29.7 32.0 34.2 32.7 34.9

119 191 257 297252 178+191 191+191 191+257 191+252 257+257178

1,657×930×765 1,657×1,240×765 1,657×1,240×765 (1,657×930×765)+(1,657×930×765) (1,657×930×765)+(1,657×1,240×765)(1,657×1,240×765)+(1,657×1,240×765)

185 200 285 325 200+200 200+285 200+305 285+285

-5 to 49

-20 to 15.5 -20 to 15.5

-5 to 49

R-410A R-410A

56 57 59 60 65 61 62 63

6.9 7.0 7.4 7.6 9.1 9.3 11.8 7.4+7.6 7.6+7.6 7.6+9.1 7.6+9.3 7.6+11.8

9.5 (Brazing) 12.7 (Brazing)

RXYQ18AYM

171,000

50.0

191,000

56.0

15.3

14.9

305

61

15.9 (Brazing) 19.1 (Brazing)

19.1 (Brazing) 22.2 (Brazing) 28.6 (Brazing) 28.6 (Brazing) 34.9 (Brazing)

RXYQ34AYMV RXYQ36AYMV RXYQ38AYMV RXYQ40AYMV RXYQ42AYMV RXYQ44AYMV

RXYQ16AYM RXYQ16AYM RXYQ18AYM RXYQ20AYM RXYQ12AYM RXYQ12AYM

RXYQ18AYM RXYQ20AYM RXYQ20AYM RXYQ20AYM RXYQ12AYM RXYQ12AYM

RXYQ18AYM RXYQ20AYM

RXYQ46AYMV RXYQ48AYMV RXYQ50AYMV RXYQ52AYMV RXYQ54AYMV RXYQ56AYMV RXYQ58AYMV RXYQ60AYMV

RXYQ14AYM RXYQ16AYM RXYQ16AYM RXYQ16AYM RXYQ18AYM RXYQ18AYM RXYQ18AYM RXYQ20AYM

RXYQ16AYM RXYQ16AYM RXYQ16AYM RXYQ18AYM RXYQ18AYM RXYQ18AYM RXYQ20AYM RXYQ20AYM

RXYQ16AYM RXYQ16AYM RXYQ18AYM RXYQ18AYM RXYQ18AYM RXYQ20AYM RXYQ20AYM RXYQ20AYM

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz 3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

Ivory white (5Y7.5/1)Ivory white (5Y7.5/1)

Hermetically sealed scroll typeHermetically sealed scroll type

(4.1×1)+(4.0×1)+(4.1×1)+(4.0×1)+(4.1×1)+(4.0×1)

(4.1×1)+(4.0×1)+(4.1×1)+(4.0×1)+(3.7×1)+(6.3×1)

(4.1×1)+(4.0×1)+(3.7×1)+(6.3×1)+(3.7×1)+(6.3×1)

(3.7×1)+(6.3×1)+(3.7×1)+(6.3×1)+(3.7×1)+(6.3×1)

257+252 297+297252+297257+297 191+191+252 191+191+297 257+257+257 257+257+252 257+252+252 252+252+252 252+252+297 252+297+297 297+297+297

(1,657×1,240×765)+(1,657×1,240×765) (1,657×930×765)+(1,657×930×765)+(1,657×1,240×765) (1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765)

285+285+285 285+305+305285+285+305 305+305+305 305+305+325 305+325+325 325+325+325

65 66 68 69 70

-20 to 15.5

-5 to 49

R-410A

9.1+9.3+9.3 9.3+9.3+9.3 9.3+9.3+11.8 9.3+11.8+11.8 11.8+11.8+11.8

19.1 (Brazing)

41.3 (Brazing)

285+305 285+325 305+325 325+325 200+200+305 200+200+325

64 66 68 65 67

-20 to 15.5

-5 to 49

R-410A

307,000

90.0

341,000

100

25.8

25.2

RXYQ32AYMV

RXYQ16AYM

RXYQ16AYM

9.3+9.3

9.3+11.8 11.8+11.8 7.6+7.6+11.8

19.1 (Brazing)

34.9 (Brazing) 41.3 (Brazing)

Capacity control

kW

%

CompressorType

Motor output

Capacity control

kW

%

Compressor

Type

Motor output

7-100 6-100 5-100

(4.1×1)+(4.0×1) (3.7×1)+(6.3×1) (4.5×1)+(5.5×1) (5.5×1)+(5.5×1) (5.5×1)+(2.9×1)+(3.3×1) (5.5×1)+(3.6×1)+(3.7×1) (5.5×1)+(4.1×1)+(4.0×1) (3.6×1)+(3.7×1)+(3.6×1)+(3.7×1)

5-100 4-100 4-100 3-100 2-1003-1003-100

(3.6×1)+(3.7×1)+(4.1×1)+(4.0×1)

(3.6×1)+(3.7×1)+(3.7×1)+(6.3×1)

(4.1×1)+(4.0×1)+(3.7×1)+(6.3×1)

(3.7×1)+(6.3×1)+(3.7×1)+(6.3×1)

(5.5×1)+(5.5×1)+(4.1×1)+(4.0×1)

(5.5×1)+(5.5×1)+(3.7×1)+(6.3×1)

(2.9×1)+(3.3×1)+(3.6×1)+(3.7×1)+(3.6×1)+(3.7×1)

(3.6×1)+(3.7×1)+(3.6×1)+(3.7×1)+(3.6×1)+(3.7×1)

(3.6×1)+(3.7×1)+(3.6×1)+(3.7×1)+(4.1×1)+(4.0×1)

(3.6×1)+(3.7×1)+(4.1×1)+(4.0×1)+(4.1×1)+(4.0×1)

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.

• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

VRV H Series

Heat Pump

67 68

VR

V S

Hig

h E

ffici

ency

Ser

ies

VRV S High Efficiency Series

Energy savings & comfort

High performance & reliability

Design flexibility of installation

Energy savings& comfort

High performance& reliability

Designflexibility ofinstallation

Higher energy efficiencyVRT Smart Control Quiet operation

Extended operation range up to 52°CHigh voltage shield PCBAutomatic refrigerant charge function

The high external static pressure of 40 Pa enables installation in small installation spaces where the airflow direction needs to be diverted to avoid short circuits.Low height casing designIncreased actual piping length up to 120 m

New VRV S High Efficiency Series achieves higher energy efficiency with a variety of function for comfort and high performance. A wide range of options for installation location and application are easily achieved by the low height casing, long piping length and other features.

The VRV S High Efficiency Series concept

The Ideal Air Conditioning System for Residential Houses, Small Offices and Shops

Cooling Only

RSUQ4-6AVMRSUQ7AYM

Heat Pump

RSUYQ4-6AVMRSUYQ7AYM

4HP–7HP

Cooling OnlyHeat Pump

(11.2 kW) (20 kW)

PresentationMovie

69 70

VRT Smart ControlVRT Smart function is available in the VRV S High Efficiency Series for the first time. Coordination between indoor and outdoor units minimizes energy consumption by optimising capacity to meet actual operation load.

The large heat exchanger and highly efficient new swing compressor reduces power consumption and realizes higher energy efficiency. Low operation sound

New fan and bell mouth help enable low operation sound.

V-cut & irregular pitch propeller fan

The fan's V-cut enables streamlined and effective airflow.

Air streams collide and generate loss

Air streams are smoothed around V-cut and reduces airflow loss

Irregular blade pitch also contributes to reduced airflow noise.

Nighttime quiet operation functionThe nighttime quiet operation function automatically suppresses the nighttime operating sound by reducing operation capacity to maintain the quiet environment of the neighborhood. Three selectable modes are available depending on the required level. This function is suitable for use in residential areas.

Energy Savings & Comfort

Higher energy efficiency Quiet operation

Energy savings Comfort

6-7 HP 4-7 HP

Cooling 4 HP 5 HP 6 HP 7 HP

New 51 51 52 58

dB(A)

Cooling Night Quiet Mode

RSU(Y)Q4/5/6A Min. 40 dB(A)

RSU(Y)Q7A Min. 45 dB(A)

Co

olin

g O

per

atio

n E

ER

VRV IV S VRV S High Efficiency Series

EER

4 HP2.0

3.0

4.0

5.0

5 HP 6 HP 7 HP

4.50

4.073.90 3.83

A˚< B˚< C˚

Old New

SeparateCollision

4-7 HP models maintain high EER in the new compact single fan design.

Notes: • For the classification of indoor units (VRT smart control and VRT control), refer to pages 77 - 78.• If a system has indoor units subject to both VRT smart and VRT control, the system is operated under VRT control.• If a system has both outdoor-air processing air conditioners and outdoor-air processing type indoor units, VRT smart control and VRT control are disabled.

Calculate• Indoor airflow rate• Target refrigerant temperature

Determine the target refrigerant temperature

Room temperature and set temperature

Compressor speed control

Peak in the outdoortemperature

8 hrs 10 hrs

8:00 12:00 16:00 20:00 0:00 4:00 8:00

50%

100%

Night mode ENDSNight mode STARTS

Night quiet mode

Min. 40 dB(A)40 dB(A)

52 dB(A)

VR

V S

Hig

h E

ffici

ency

Ser

ies

VRV S High Efficiency Series

Coordinated control

Notes: • This function is available in setting at site.• The operating sound in quiet operation mode is the actual value

measured by our company. • The relationship of outdoor temperature (load) and time shown

above is just an example.• In case of 4-6 HP outdoor unit

Load %

Operating sound dB(A)

71 72

The large heat exchanger ensures sufficient cooling capacity even in high ambient temperatures.

The outdoor operation temperature range is now extended to 52ºC.This enables reliable operation even under high temperature conditions and a wider choice of installation locations.

New heat exchanger

High Performance & ReliabilityHigh temperature operationExtended operation range up to 52°C

Rated cooling capacity can be maintained even when outdoor temperature is up to 43°C.

Keep rated cooling capacity in high outdoor temperature up to 43°C

Refrigerant cooled PCBDaikin’s unique refrigerant cooling helps maintain high cooling capacity even during high outdoor temperatures.

• 2-sided 3-row• Heat exchanger area 68%UP

(4,5 HP model only)

Cooling capacity

Outdoor temperature (°CDB)

52°C0 10 20 30 40 46-5

New VRV S High Efficiency Series

The refrigerant-cooled PCB and large 3-row heat exchanger raise the maximum cooling outdoor operation temperature from 46°C to 52°C.

Cooling

Previous VRV IV S Series

100%

43 523510 39

New VRV S High Efficiency Series

Previous VRV IV S Series

Outdoor temperature (°CDB)

VR

V S

Hig

h E

ffici

ency

Ser

ies

VRV S High Efficiency Series

The high voltage shield PCB protects the electrical parts and prevents malfunctions at the highest voltage of 440 V.

* Continuous operation range is 198 to 264 V.

Contribute to optimised operation efficiency, higher quality and easier installation.

This function prevents a capacity shortage or energy loss due to excessive or insufficient refrigerant.

High voltage shield PCB (4-6 HP model only)

Automatic refrigerant charge function

Optimised operation efficiency

Higher quality and easier installation

Optimised Operation

Efficiency Cooling capacity

Optimal refrigerantamount

Refrigerant charge amount

Insufficientrefrigerant charge

Excessiverefrigerant charge

Max.440 V

* Must use automatic refrigerant charge function. Refer to installation manual for details.

・Automatic completion by proper refrigerant amount・Monitoring refrigerant charging is unnecessary・No recalculation of charge amounts due to minor design changes locally

Automatic Refrigerant Charge

R-410A

The automatic refrigerant charge function automates the charging of the proper refrigerant amount and easy start by pressing one button.

Calculation of necessary refrigerant amount from design drawing

1 Start of automatic refrigerant charge operation

2

Improved performanceThe new DC motor designed with small-diameter bearing and improved efficiency during low-speed operation has improved seasonal efficiency.

High-capacity

swing structure

New DC motor

(high wire-efficiency winding/

high-efficiency magnet)

The new compressors offer higher performance compared to that of conventional scroll compressors.

New swing compressor

High efficiency, high capacity DC inverter swing compressor

73 74

The new VRV S High Efficiency Series outdoor unit has been achieved high external static pressure up to 40 Pa, realizing stable operation in small installation sites where the air direction adjustment grille or duct is used to avoid short circuits.

When discharged air is blocked by some obstacle, the optional air direction adjustment grille can divert the airflow to one of 4 directions (up, down, left or right) to avoid the obstacle.

The external static pressure automatic adjustment function maintains rated airflow and capacity by automatically adjusting the external static pressure during the test operation to suit the resistance of the installation site.

The new design has been optimised for the VRV S High Efficiency Series with the height of all models reduced to only 870 mm. This low height casing design provides occupants with a clear, unobstructed view of the scenery.

Previous VRV IV S series

Design Flexibility of InstallationNo short circuits Low height casing designHigh external static pressure up to 40 Pa and automatic adjustment of external static pressure

Optimum airflow direction with the optional air direction adjustment grille

Air direction adjustment grille (option)

When the obstacle is not avoidable by the air direction adjustment grille, installing a field-supplied duct can bypass the obstacle. In this way, installation of the outdoor unit is possible in places like behind an advertising board.

Airflow (m3/min)

Wind is diverted upwards.

Wind is diverted sideways.

4,5 HP 6 HP

990

mm

1,34

5 m

m

870mm

4-7 HP

1

2

3

Airflow decreases.

Airflow (rated)Airflow (rated)

Resistance increases when duct is installed in the site.

External static pressure (Pa)

Rated airflow is maintainedRated airflow is maintained.

Duct(Field supply)

Flange(Field supply)Duct installation to stabilize the system

VR

V S

Hig

h E

ffici

ency

Ser

ies

VRV S High Efficiency Series

The low height casing design allows for compact double-stacking of outdoor units to maximize utilization of installation space.

・Ideal solution that minimises both visual and sound impact・Can be installed in a wide variety of locations and applications・No space required for multiple outdoor units

Window

Outdoorunit

View from outside View from inside

Double-stacking installation possible

75 76

Actual piping length increased by 20% allows for various installation!

Installation for VRV indoor units only

Design Flexibility of Installation

100 m

Increased actual piping length up to 120 m*

120 m*

Installation on the rooftop of residential apartments

Previous VRV IV S series

Max. 40 m

Between the first indoor branch and the farthest indoor unit

Max. level difference between the indoor units

50 m

Max. level difference between the outdoor units and the indoor units

15 m

Note: The above is just a schematic diagram.

Max. equivalent piping length

150 m

120 m*

5-7 HP

Maximum allowable level difference

Maximum allowable piping length

Between the outdoor units and the indoor units

Between the indoor units

Between the first indoor branch and the farthest indoor unit

Total piping length

Actual piping length (Equivalent)

15 m

120 m* (150 m)

300 m

50 m

40 m

40 m

4 HP

10 m

120 m* (150 m)

300 m

50 m

40 m

40 m

If the outdoor unit is above.

If the outdoor unit is below.

Max. actual piping length

300 mMax. total piping length

VR

V S

Hig

h E

ffici

ency

Ser

ies

VRV S High Efficiency Series

* Must use automatic refrigerant charge function.Refer to installation manual for details.

Installation for mixed combination of VRV and residential indoor units

Installation on balconies of residential apartments

One outdoor unit can provide comfort for the whole house

Max. total piping length 300 m

Max. equivalent piping length

Max. actual piping length

Between the first indoor branch and the farthest VRV indoor unit

Max. level difference between the indoor units

15 m

15 m Max. level difference between the outdoor unit and the indoor unit

50 m

5 m

Note: The above is just a schematic diagram.

BP unit

RA

RA

RA

RA

VRV

BP unit

Max. 15 m

Between BP unit and indoor unitMax. level difference between the

outdoor unit and the BP units

40 m

Max. level difference between BP unit

Max. level difference between the BP unit and the indoor unit

VRV: VRV indoor unit RA: Residential indoor unit

Max. 40 m

Maximum allowablepiping length

Minimum allowable piping length

Maximum allowablelevel difference

Between the outdoor unitand the indoor unit

Between BP unit and indoor unit

Between the indoor units

Between BP units

Between the first indoor branch and the farthest BP unit or between the first indoor branch and the farthest VRV indoor unit

Total piping length

Actual piping length (Equivalent)

Between outdoor unit and the first indoor branch

If the outdoor unit is above.

If the outdoor unit is below.

If indoor unit capacity index < 60.

If indoor unit capacity index is 60.

If indoor unit capacity index is 71.

Between the outdoor unit and the BP unit

Between the BP unit and the indoor unit

120 m*

145 m

* Must use automatic refrigerant charge function.Refer to installation manual for details.

15 m

15 m

120 m* (145 m)

300 m

2 m–15 m

2 m–12 m

2 m–8 m

40 m

5 m

50 m

40 m

40 m

10 m

10 m

120 m* (145 m)

300 m

2 m–15 m

2 m–12 m

2 m–8 m

40 m

5 m

50 m

40 m

40 m

4 HP

5 m 5 m

5-7 HP

Cei

ling

Con

ceal

ed D

uct

Floo

r St

andi

ngCe

iling

Susp

ende

dC

ateg

ory

Cei

ling

Mou

nted

Cas

sett

e

Indoor Unit Lineup

77 78

Indoor units can be selected from 2 lineups, both VRV and residential indoor units, to match rooms and preferences.

Wide variety of indoor units

VRV indoor units VRT smart VRT

Indoor units subject to VRT smart control

Indoor units subject to VRT control

FXDSQ-AVM

FXSQ-PAVE

Capacity Range

Capacity Index 20

0.8 HP

20

1.6 HP

40

2.5 HP

63

3.2 HP

80

3 HP

71

4 HP

100

5 HP

125

6 HP

140

2 HP1.25 HP

32

62.531.25

1 HP

25

Type Model Name

FXFSQ-AVM

Ceiling Suspended

Wall Mounted

Floor Standing

Concealed Floor Standing

Outdoor-Air Processing Unit

FXVQ-NY1Floor Standing Duct

FXDQ-SPV1

FXMQ-MFV1

Heat Reclaim Ventilator VAM-GJVE Airflow rate 150-2000 m3/h

Clean Room Air ConditionerFXBQ-PVE

FXBPQ-PVE

FXEQ-AV36

FXFQ-AVM

FXZQ-AVM

FXCQ-AVM

FXMQ-PAVE

FXHQ-AVM

FXHQ-MAVE

FXAQ-AVM

FXLQ-MAVE

FXNQ-MAVE

FXDQ-PDVE(with drain pump)

FXDQ-PDVET(without drain pump)

FXDQ-NDVE(with drain pump)

FXDQ-NDVET(without drain pump)

(700 mm width type)

(900 / 1,100 mm width type)

50

40 8071 100 125 140

8 HP

200

20025 50

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

VRT smart

4-Way Flow Ceiling Suspended

FXUQ-AVEB VRT

VRT

VRT

VRT

VRT

VRT

VRT

VRT

Spot Air Conditioner VRT

VRT

VRT

VRT

Residential indoor units only

BP unit BP unit

VRV indoor units only

11Max.

indoor units

• If a system has indoor units subject to both VRT smart and VRT control, the system is operated under VRT control.• If a system has both outdoor-air processing air conditioners and outdoor-air processing type indoor units, VRT smart control and VRT control are disabled.

11Max.

indoor units

• BP units are necessary for residential indoor units.• If a system has only residential indoor units, the system is operated under VRT control.

3D Airflow Duct with Sensing

Middle Static Pressure Duct

Round Flow Cassette with Sensing

Round Flow Cassette

Compact Multi Flow Cassette

Double Flow Cassette

Single Flow Cassette

Slim Duct (Standard)

Middle-High Static Pressure Duct

FXMQ-PVM VRT smartHigh Static Pressure Duct

Slim Duct (Compact)

Residential indoor units with connection to BP units

Note: BP units are necessary for residential indoor units.

20

20

2.0

25 35

25 35

2.5 3.5

50 60 71

50 60 71

5.0 6.0 7.1Rated Capacity (kW)Type Model Name

Capacity Index

Slim CeilingConcealed Duct

Wall Mounted

(700 mm width type)

(900/1,100 mm width type)

Cooling Only

Heat Pump

FDKS-EAVMB

CDXS-EAVMA

Cooling Only

Heat Pump

FDKS-C(A)VMB

FDXS-CVMA

Cooling OnlyHeat PumpHeat Pump

FTKS-DVMFTXS-DVMAFTXS-EVMA

Cooling Only FTKS-BVMA

Cooling OnlyHeat Pump

FTKS-FVMFTXS-FVMA

VRT

VRT

VRT

VRT

VRTVRTVRT

VRT

VRT

VRT

FXPQ-AVN

New lineup

Cooling Only

Cooling Only

FTKJ-NVMVW

FTKJ-NVMVS

VRT

VRT

VR

V S

Hig

h E

ffici

ency

Ser

ies

VRV S High Efficiency Series

79 80

Heat PumpCooling Only

Outdoor Units

Note: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

• Refrigerant charge is required.

Note: Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor unit.

Specifications

Outdoor unit combinations

Specifications

Outdoor unit combinations

MODEL RSUQ4AVM RSUQ5AVM RSUQ6AVM RSUQ7AYM

kW 11.2 14.0 16.0 20.0

HP 4 5 6 7

Capacity index 100 125 150 175

Combination (%)

50% 50 62.5 75 87.5

100% 100 125 150 175

130% 130 162.5 195 227.5

Maximum number of connectable indoor units 6 8 9 11

Note: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

• Refrigerant charge is required.

MODEL RSUYQ4AVM RSUYQ5AVM RSUYQ6AVM RSUYQ7AYM

kW 11.2 14.0 16.0 20.0

HP 4 5 6 7

6 8 9 11

Capacity index 100 125 150 175

Combination (%) 80%*2 80 100 120 140

50%*1 50 62.5 75 87.5

100% 100 125 150 175

130% 130 162.5 195 227.5

Maximum number of connectable indoor units

MODEL RSUQ4AVM RSUQ5AVM RSUQ6AVM RSUQ7AYM

Power supply 1-phase, 220-240 V/220-230 V, 50/60 Hz 3-phase, 380-415 V/380 V, 50/60 Hz

Cooling capacity Btu/h 38,200 47,800 54,600 68,200

kW 11.2 14.0 16.0 20.0

Power consumption kW 2.49 3.44 4.10 5.46

Capacity control % 23 to 100 16 to 100 9 to 100

Casing colour

Compressor Type

Motor output kW 2.0 3.1 3.5

Airflow rate m3/min 87 84 87

mm 870×1,100×460

Machine weight kg 95 98 115

58Sound level dB(A) 51 52

Operation range °CDB -5 to 52

4.24.0Refrigerant

Type R-410A

Charge kg 5.4

Piping connections Liquid mm

Gas mm 15.9 (Flare)

MODEL RSUYQ4AVM RSUYQ5AVM RSUYQ6AVM RSUYQ7AYM

Power supply 1-phase, 220-240 V/220-230 V, 50/60 Hz 3-phase, 380-415 V/380 V, 50/60 Hz

Cooling capacity Btu/h 38,200 47,800 54,600 68,200

42,700 54,600 61,400 76,400

kW 11.2 14.0 16.0 20.0

12.5 16.0 18.0 22.4Heating capacity

Btu/h

kW

Cooling kW 2.49 3.44 4.10 5.46

Heating kW 2.54 3.37 3.98 5.10

Capacity control % 23 to 100 15 to 100 9 to 100

Casing colour

Compressor Type

Motor output(Cooling / Heating) kW 2.0/2.4 3.1/3.6 3.5/4.0

Airflow rate Cooling m3/min

m3/min

87 84 87

Dimensions (H×W×D) mm 870×1,100×460

Machine weight kg 95 98 120

Sound level (Cooling/Heating) dB(A) 51/52 52/54 58/61

Operation range Cooling °CDB -5 to 52

Heating °CWB -20 to 15.5

Refrigerant Type R-410A

Charge kg 4.0 4.2 5.4

Piping connections Liquid mm

Gas mm 15.9 (Flare)

Ivory white (5Y7.5/1)

Hermetically sealed swing type

1.9

123 Ivory white (5Y7.5/1)

Hermetically sealed swing type

1.9/2.3

123

Heating 90 84 94 137

Dimensions (H×W×D)

9.5 (Flare)

9.5 (Flare)

19.1 (Brazing)

19.1 (Brazing)

Power consumption

Total capacity index of connectable indoor units

Notes: 1. When only VRV indoor units are connected, total capacity index of connectable indoor units must be 50%-130% of the capacity index of the outdoor unit.2. When a mixed combination of VRV and residential indoor units is connected or when only residential indoor units are connected, total capacity index

of connectable indoor units must be 80%-130% of the capacity index of the outdoor unit.

Total capacity index of connectable indoor units

VR

V S

Hig

h E

ffici

ency

Ser

ies

VRV S High Efficiency Series

VRV S High Efficiency Series

VR

V IV

S S

erie

s

81 82

VRV IV S Series

Compact & lightweight design

The VRV IV S series is slim and compact, with outdoor units that require minimal installation space.

940 mm

990 mm

320 mm 940 mm

1,430 mm

320 mm

4 HP 5 HP 6 HP 8 HP / 9 HP

71 kgProduct Weight 76 kg* 78 kg* 131 kg*990 mmHeight 990 mm 990 mm 1,430 mm

0.30 m2Footprint 0.30 m2 0.30 m2 0.30 m2

8HP / 9HP4HP — 6HP

The Ideal Air Conditioning System for Residential Houses, Small Offices and Shops 4HP–9HP

(11.2 kW) (24 kW)

Cooling OnlyHeat Pump

Co

olin

g O

per

atio

n E

ER

VRV III S VRV IV S Series

High Energy Efficiency Ratio (EER)

VRV IV S series provides greater energy saving as compared to VRV III S series.

Energy saving

0

3.2

3.4

3.6

3.8

4

4 HP(11.2 kW)

5 HP(14.0 kW)

6 HP(16.0 kW)

8 HP(22.4 kW)

9 HP(24.0 kW)

*Cooling operation conditions: Indoor temp. of 27º CDB,19º CWB, and outdoor temp. of 35º CDB.

*For cooling only models

3.89

3.55

3.77

3.49

3.66

Cooling Only

RXMQ4AVERXMQ5-6BVMRXMQ8-9AY1

Heat Pump

RXYMQ4AVERXYMQ5-6BVMRXYMQ8-9AY1

83 84

VR

V IV

S S

erie

s

VRV IV S Series

Technologies for efficient and quiet operation

Swing compressor (4-6 HP model only)

Comfort and Simplified Installation

Quiet operation

Nighttime quiet operation function

The nighttime quiet operation function automatically suppresses the nighttime operating sound by reducing operation capacity to maintain the quiet environment of the neighborhood. Three selectable modes are available depending on the required level. This function is suitable for use in residential areas.

Daikin swing compressor has integrated the rotor with the blade, completely solving the refrigerant leakage and the wear problem caused by the mechanical friction between the rotor and the blade, which enhances the compressor efficiency and makes the compressor more quiet and durable.

DC fan motor

Efficiency improved in all areas compared to conventional AC motors, especially at low speeds.

Smooth air inlet bell mouth and aero spiral fan

The smooth air inlet bell mouth and the aero spiral fan work to minimize turbulence in the airflow and reduce sound.

The structural scroll (8-9 HP model only)

Sucked gas is compressed in the scrolling part before the heated motor, so that the machine compress the non-expanded gas, resulting in high efficiency compression.

Swing compressor

Peak in the outdoortemperature

8 hrs 10 hrs

8:00 12:00 16:00 20:00 0:00 4:00 8:00

50%

100%

Night mode ENDSNight mode STARTS

Night quiet mode

Min. 43 dB(A)43 dB(A)

52 dB(A)

Load %

Operating sound dB(A)

Scroll section

Suction

DischargeMotorsection

Notes: • This function is available in setting at site.• The operating sound in quiet operation mode is the actual value measured by our

company. • The relationship of outdoor temperature (load) and time shown above is just an

example.• In case of 4 HP outdoor unit

8, 9 HP

4-6 HP

Scroll compressor

When only VRV indoor units are connected

Long piping length offers flexibility in the choice of installation positions, and simplifies system planning.

When a mixed combination of VRV and residential indoor units is connected

Makes the long piping design possible

Max. allowable level difference

Max. allowable piping length

Between the outdoor unitand the indoor unit

Between the indoor units

Between the first indoor branch and the farthest indoor unit

Total piping length

Refrigerant piping length (Equivalent)

j

a+b+c+d+e+f+g+h+i

a+b+c+d+i

b+c+d+i

50 m (65 m)

250 m

40 m

4 HP

100 m (130 m)

300 m

40 m

5,6 HP

kIf the outdoor unit is aboveIf the outdoor unit is below k

10 m

30 m

30 m

15 m

30 m

30 m

70 m (90 m)

300 m

40 m

8,9 HP

15 m

50 m

40 m

Max. allowable piping length

Max. & min. allowable piping length

Min. allowable piping length

Max. allowable level difference Outdoor unit -

the indoor unit

BP unit - indoor unit

Between the indoor units

Between BP units

The first indoor branch - the farthest BP or VRV indoor unit

Total piping length

Refrigerant piping length (Equivalent)

Outdoor unit - the first indoor branch

10 m

10 m

l

m

n

n

o

a+b+c+d+e+f+g+h+i+j+k

b+c+g, b+c+d

a+b+c+g+k, a+b+c+d

h, i, j, k

a

50 m (65 m)

250 m

40 m

2 m–15 m

2 m–12 m

2 m–8 m

5 m

30 mIf the outdoor unit is aboveIf the outdoor unit is below

If indoor unit capacity index < 60

If indoor unit capacity index is 60

If indoor unit capacity index is 71

30 m

30 mOutdoor unit - the BP unit

4 HP

15 m

15 m

70 m (90 m)

250 m

40 m

2 m–15 m

2 m–12 m

2 m–8 m

5 m

30 m

30 m

30 m

5,6 HP

15 m

15 m

100 m (125 m)

250 m

40 m

2 m–15 m

2 m–12 m

2 m–8 m

5 m

50 m

40 m

40 m

8,9 HP

Max. 100 m

Actual piping length

Max. 300 m

Total piping length

Max. 130 m

Equivalent piping length

Max. 100 m

Actual piping length

Max. 250 m

Total piping length

Max. 125 m

Equivalent piping length

Max.

50 m

Max.

15 m

a

i

j

k

dcbhgfe

First indoor branch

Max.

50 m

Max.

40 mMax.

15 m

Max.

15 m

a

o

l

n

dcbgfe

First indoor branch

mh ij

k

BP

RA RA

RA

VRV

VRV

BP

RA

85 86

VR

V IV

S S

erie

s

VRV IV S SeriesFl

oor

Stan

ding

Ceilin

g Su

spen

ded

Cat

egor

yC

eilin

g M

ount

ed C

asse

tte

Cei

ling

Con

ceal

ed D

uct

3D Airflow Duct with Sensing

Middle Static Pressure Duct

Round Flow Cassette with Sensing

Round Flow Cassette

Compact Multi Flow Cassette

Double Flow Cassette

Single Flow Cassette

Slim Duct (Standard)

Middle-High Static Pressure Duct

High Static Pressure Duct

Slim Duct (Compact)

A mixed combination of VRV indoor units and residential indoor units can be combined into one system, opening the door to stylish and quiet indoor units.

Indoor Unit Lineup

Enhanced range of choices

VRV indoor units

FXDSQ-AVM

FXSQ-PAVE

Capacity Range

Capacity Index 20

0.8 HP

20

1.6 HP

40

2.5 HP

63

3.2 HP

80

3 HP

71

4 HP

100

5 HP

125

6 HP

140

2 HP1.25 HP

32

62.531.25

1 HP

25

Type Model Name

FXFSQ-AVM

Ceiling Suspended

Wall Mounted

Floor Standing

Concealed Floor Standing

Outdoor-Air Processing Unit

FXVQ-NY1Floor Standing Duct

FXDQ-SPV1

FXMQ-MFV1

Heat Reclaim Ventilator VAM-GJVE Airflow rate 150-2000 m3/h

Clean Room Air ConditionerFXBQ-PVE

FXBPQ-PVE

Spot Air Conditioner

FXEQ-AV36

FXFQ-AVM

FXZQ-AVM

FXCQ-AVM

FXMQ-PAVE

FXHQ-AVM

FXHQ-MAVE

FXAQ-AVM

FXLQ-MAVE

FXNQ-MAVE

FXDQ-PDVE(with drain pump)

FXDQ-PDVET(without drain pump)

FXDQ-NDVE(with drain pump)

FXDQ-NDVET(without drain pump)

(700 mm width type)

(900/1,100 mm width type)

50

40 8071 100 125 140

8 HP

200

10 HP

250

200 25025 50

VRV indoor units combine with residential indoor units, all in one system.

* Refer to page 87 - 88 for the maximum number of connectable indoor units.

VRV indoor units

BP unit

Residential indoor units

VRV indoor units only

20

20

2.0

25 35

25 35

2.5 3.5

50 60 71

50 60 71

5.0 6.0 7.1Rated Capacity (kW)Type Model Name

Capacity Index

Slim CeilingConcealed Duct

Wall Mounted

(700 mm width type)

(900/1,100 mm width type)

Note: BP units are necessary for residential indoor units.

Cooling Only

Heat Pump

FDKS-EAVMB

CDXS-EAVMA

Cooling Only

Heat Pump

FDKS-C(A)VMB

FDXS-CVMA

Cooling Only

Heat Pump

FTKS-FVM

FTXS-FVMA

Cooling OnlyHeat PumpHeat Pump

FTKS-DVMFTXS-DVMAFTXS-EVMA

Cooling Only FTKS-BVMA

Cooling Only

Heat Pump

FTKJ-NVMVW

FTXJ-NVMVW

Cooling Only

Heat Pump

FTKJ-NVMVS

FTXJ-NVMVS

Residential indoor units with connection to BP units

FXPQ-AVN

4-Way Flow Ceiling Suspended FXUQ-AVEB

14Max.

indoor units

14Max.

indoor units

New lineup

FXMQ-PVM

VR

V IV

S S

erie

s

87 88

VRV IV S Series

38,200

11.2

2.88

24 to 100

47,800

14.0

3.83

54,600

16.0

4.51

Ivory white (5Y7.5/1)

RXMQ4AVE RXMQ5BVM RXMQ6BVM RXMQ8AY1 RXMQ9AY1

15 to 100

Btu/h

kW

kW

%

kW

m3/min

mm

kg

dB(A)

°CDB

kg

mm

Casing colour

Compressor

Airflow rate

Machine weight

Sound level

Operation range

Refrigerant

Piping connections

Power supply

Cooling capacity

MODEL

Dimensions (H×W×D)

Type

Motor output

Type

Charge

Liquid

Gas

Power consumption

Capacity control

Hermetically sealed swing type

3.7

-5 to 46

R-410A

3.21.92

76 81

71 76

53

80

78

5552

3.4 4.02.9

9.5 (Flare)

15.9 (Flare)

1-phase, 220-240 V/220-230 V, 50/60 Hz 1-phase, 220-230 V/220 V, 50/60 Hz

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27° CDB, 19° CWB, Outdoor temp.: 35° CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

• Refrigerant charge is required.

Outdoor Units

Specifications

VRV IV S Series

76,400

22.4

5.94

81,900

24.0

6.88

20 to 100

Hermetically sealed scroll type

4.83.8

140

1,430×940×320

131

5.8

57 58

9.5 (Brazing)

19.1 (Brazing) 22.2 (Brazing)

3-phase, 380–415 V, 50 Hz

RXMQ4AVE RXMQ5BVM RXMQ6BVM

11.2

4

100

50

100

130

6

14.0

5

125

62.5

125

162.5

8

16.0

6

150

75

150

195

9

50%

100%

130%

kW

HP

Capacity index

Total capacity index of connectable indoor units

Maximum number of connectable indoor units

MODEL

Outdoor unit combinationsRXMQ8AY1

22.4

8

200

100

200

260

13

RXMQ9AY1

24.0

9

215

107.5

215

280

14

Note: Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor unit.

Combination (%)

990×940×320

38,200

11.2

42,700

12.5

2.88

2.60

47,800

14.0

47,800

14.0

3.83

3.04

54,600

16.0

54,600

16.0

4.51

3.59

Ivory white (5Y7.5/1)

RXYMQ4AVE RXYMQ5BVM RXYMQ6BVM

24 to 100

Hermetically sealed swing type

15 to 100

3.7

80

80

55/56

-5 to 46

-20 to 15.5

R-410A

3.2/3.5

81

1.92

76

990×940×320

71 78

53/5452/54

3.4 4.02.9

Btu/h

kW

Btu/h

kW

kW

%

kW

m3/min

mm

kg

dB(A)

°CDB

°CWB

kg

mm

Casing colour

Compressor

Airflow rate

Machine weight

Sound level (Cooling/Heating)

Operation range

Refrigerant

Piping connections

Power supply

Heating capacity

Cooling capacity

MODEL

Cooling

Heating

Cooling

Heating

Type

Charge

Liquid

Gas

Dimensions (H×W×D)

Type

Motor output(Cooling/Heating)

Power consumption

Capacity control

9.5 (Flare)

15.9 (Flare)

1-phase, 220-230 V/220 V, 50/60 Hz 1-phase, 220-240 V/220-230 V, 50/60 Hz

RXYMQ4AVE RXYMQ5BVM RXYMQ6BVM

11.2

4

100

50

80

100

130

6

14.0

5

125

62.5

100

125

162.5

8

16.0

6

150

75

120

150

195

9

50%*1

80%*2

100%

130%

kW

HP

Capacity index

Total capacity index of connectable indoor units

Maximum number of connectable indoor units

MODEL

Combination (%)

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp. : 27° CDB, 19° CWB, Outdoor temp. : 35° CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20° CDB, Outdoor temp.: 7° CDB, 6° CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.When there is concern for noise the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

• Refrigerant charge is required.

Notes: *1 : When only VRV indoor units are connected, total capacity index of connectable indoor units must be 50%-130% of the capacity index of the outdoor unit.*2 : When a mixed combination of VRV and residential indoor units is connected or when only residential indoor units are connected, total capacity index of connectable

indoor units must be 80%-130% of the capacity index of the outdoor unit.

Specifications

Outdoor unit combinations

Heat Pump

RXYMQ8AY1

22.4

8

200

100

160

200

260

13

RXYMQ9AY1

24.0

9

215

107.5

172

215

280

14

76,400

22.4

85,300

25.0

5.94

6.25

81,900

24.0

88,700

26.0

6.88

6.82

RXYMQ8AY1 RXYMQ9AY1

20 to 100

Hermetically sealed scroll type

4.83.8

140

1,430×940×320

138

5.8

57/58 58/59

9.5 (Brazing)

19.1 (Brazing) 22.2 (Brazing)

3-phase, 380–415 V, 50 Hz

Cooling Only

89 90

VR

V IV

Q S

erie

s

VRV IV Q Series

Special equipment and work is no longer required to clean pipes. A new function automatically deals with contamination inside piping during refrigerant charging, eliminating the work involved in cleaning.

The VRV IV Q Series concept

Quick, quality and economical replacement

Reuse

Simple use of existing refrigerant piping

Even applicable for non-DAIKIN systems! The Daikin low-cost upgrade solution

Reuse drain pipes

Reuse refrigerant branch pipesThere are no restrictions when upgrading from a Daikin VRV system. Other VRF systems require branch pipes withstand pressure up to 3.3 MPa.

Reuse refrigerant pipesPipes used for R-22 will also work with VRV IV Q series.

Replace indoor units

Reuse remote control and indoor-outdoor wiringReuse wiring when upgrading from a Daikin VRV system.In other cases, this will depend on the cable type.

Replace outdoor units

Reusing existing refrigerant piping

minimizes installation time and cost

Improvement in capacity

and greater number of indoor units

An automatic refrigerant charge function enables

high quality installation

For Quick & High Quality Replacement Use

6HP–48HP

Cooling OnlyHeat Pump

(16 kW) (135 kW)

Single outdoor units

RQ(Y)Q6-16TYM(1)(E)

Double outdoor units

RQ(Y)Q18-32TNYM(1)(E)

Triple outdoor units

RQ(Y)Q34-48TNYM(1)(E)

Single outdoor units

RQ(Y)Q18-20TYM(1)(E)

Double outdoor units

RQ(Y)Q30-40TSYM(1)(E)

Triple outdoor units

RQ(Y)Q42-48TSYM(1)(E)

* (E) : anti-corrosion model

Standard Type Space Saving Type

91 92

VR

V IV

Q S

erie

s

VRV IV Q Series

Time savingEnables smooth replacement of air conditioning with less effect on operations and users in the building.

Significantly more compact outdoor unit enables the effective use of limited space!Refrigerant charging, cleaning and test operation done with just a single switch.

More indoor units can be connected in a single system, enabling consolidation of existing piping!

Compact design enables the effective use of space taken up by existing machinery

An increased number of connectable indoor units in a single system

Automatic Design flexibility

High external static pressure 78.4 Pa

System flexibility

Cost savingBy the reuse of existing piping, 35% of cost down can be realized compared to installing new pipes.

The automatic refrigerant charge function automates the charging of the proper refrigerant amount and the closing of shut-off valves by simply pressing a switch after pre-charging.Furthermore, there is no need to clean inside piping as this is handled automatically by the VRV IV Q unit.

* There are conditions in the range (ambient temperature, connection ratio) in which the automatic refrigerant charge can be used. Refer to the installation manual for details. The refrigerant amount that can be automatically charged may differ from the additional refrigerant amount that is provided from calculations, but there are no problems in performance and quality.

Cost details (10 HP example)

Piping

Duct

CuringOverheads

Equipment installation

Removal work

Refrigerant charge

40%

10%

10%

10%

8%4%

20%

20%

10%

10%

10%

4%

6%

New pipe installation VRV IV Q series

Approx.

–35%

Great reduction of work cost

Conventional solution

Refrigerant recovery and units removal

Carry-in and installation of units

Airtightness test

Vacuum drying

Quicker and higher qualityinstallation

Removal of existing piping

Installation of new piping and wiring

Refrigerant charging and volume measurement

Test operation

1

4

5

6

2

3

7

8

Refrigerant recovery and units removal

Airtightness test

Vacuum drying

Automatic

Reuse of existing refrigerant piping

Carry-in and installation of units

1

4

5

6

2

3

Quicker

Quicker

VRV IV Q seriesfor Replacement use

3,005 mm 750 mm

ConventionalVRV K PLUS series: RX(Y)20K20 HP outdoor unit

Installation space

Installation space

2.25m2

0.95m2

20 HP outdoor unitVRV IV Q : RQ(Y)Q20T

1,240 mm 765 mm

Conventional VRV K PLUS series: RX(Y)24–30K

49.0Pa

VRV IV QConventionalVRV K series

58%less space

indoor unitsconnectableUp to 30

VRV IV Q : RQ(Y)Q40–48T

indoor unitsconnectableUp to 64

Benefits of System Replacement

78.4 Pa

3%

Refrigerant charge, refrigerant pipe cleaning, test operation

93 94

VR

V IV

Q S

erie

s

VRV IV Q Series

Outer Rotor DC Motor (ODM)

Only Daikin has adapted an ODM with the feature of stable rotation and volumetric efficiency.

Benefits of System Replacement

New tested contamination collection methodA new method collects contamination from existing piping, eliminating compressors and electric valves malfunction.

Enables increased capacity

Energy saving

Higher Energy Efficiency Ratio (EER)

VRT Control for optimal annual efficiency

Reliable and stable technology

New technology that enables use of existing piping

High reliability at high ambient temperatures

PCB

Power Module

RefrigerantRefrigerant JacketHeat

Refrigerant

Using refrigerant to cool the inverter power module helps minimise the size of the electronic components, and this results in reduction of airflow resistance and high efficiency of the heat exchanger.

This enables

UNIQUE

F

Rotor

SMT* packaging technology

• Improves the anti-clutter performance.• Protects your computer boards from the adverse effects of sandy climates and humid weather.

*SMT: Surface mounted technology

SMT packaging material

Computer control board

Computer control board surface adopting SMT packaging technology

Control board failure ratio at stable operation is reduced.

• Suitability for high ambient temperatures• Miniaturization of electronic components

VRV IV Q series only VRV IV Q series for replacement use enables the system capacity to be increased without changing the refrigerant piping. For example, it is possible to install a 16 HP VRV IV Q series using the refrigerant piping of an 10 HP R-22 system.

Acid Impurities Iron powderAn acid neutraliser agent is added to disable acids (chlorine ions), which cause corrosion.

A generously sized filter is provided inside the refrigerant circuit which traps impurities.

A magnet is installed inside the accumulator where liquid refrigerant accumulates. The magnet attracts iron powder to keep the system clean.

Acid (chlorine ion)

Refrigerant pipe

Acid neutraliser

AccumulatorIron powder

To compressor

Refrigerant flow

Filter

Iron powder, etc

Impurities

Magnet

Reuse of existing piping

Pipe size: 28.6, 12.7

Pipe size: 28.6, 12.7

* Cooling operation conditions: Indoor temp. of 27º CDB, 19º CWB, and outdoor temp. of 35º CDB.

VRV IV Q series delivers highly efficient performance, contributing to high energy savings.

VRT automatically adjusts refrigerant temperature to individual building and climate requirement, thus further improving annual energy efficiency and maintaining comfort.

VRV K(A): RSX-K(A) VRV II: RX-M VRV IV Q Series

4.0

3.0

5.0

2.0

1.0

0

Co

olin

g O

per

atio

n E

ER

8 HP6 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP

81% increase(Compared with 8 HP model of VRV K(A) )

4.324.414.07

3.80 3.743.46 3.25 3.11

2.5HP×4 units

4.0HP×4 units

Before replacement

10HP

After replacement

16HP

VRV IV Q Series

Replace Replace

ODM (Outer Type)Conventional Motor(Inner Type)

F

Rotor HIGH TORQUEwith low energy

MORE efficient

95 96

VR

V IV

Q S

erie

s

VRV IV Q Series

p

q

k

First outdoor branch

fab

Firstindoor branch

*The rest of indoor units are the same as for single use.

First indoor branch

Single use

Multiple use

Colours in the diagram above are merely for identifying pipes referenced with symbols such as a .

Maximumallowablelevel difference

Maximumallowablepiping length

Between the outdoor unitsand the indoor units

Between the indoor units

Between the outdoor units (Multiple use)

Between the first indoor branch and the farthest indoor unit

Between the outdoor branch and the last outdoor unit (Equivalent)

Total piping length

Actual refrigerant piping length (Equivalent)

15 m

5 m q

s

a+b+c+d+e+f+g+h+i

a+f+g+h+i

f+g+h+i

k+p

150 m (175 m)

300 m

40 m

10 m (13 m)

Piping length Example

Level Difference Example

50 m rIf the outdoor unit is above.

If the outdoor unit is below. 40 m r

6 HP 8 HP10 HP12 HP14 HP16 HP18 HP20 HP22 HP24 HP26 HP28 HP30 HP32 HP34 HP36 HP38 HP40 HP42 HP44 HP46 HP48 HP

< 100100 ≤ X < 150150 ≤ X < 160160 ≤ X < 200200 ≤ X < 290290 ≤ X < 330330 ≤ X < 420420 ≤ X < 480480 ≤ X < 640640 ≤ X < 900900 ≤ X < 920

920 ≤ 20–40 class

50 class63-80 class

100–125 class140 class200 class250 class400 class500 class

: Piping size of conventional R-22 model: Piping size of conventional R-410A model: Standard piping size of VRV IV Q series: Possible: Standard piping size of VRV IV Q series. However, when equivalent piping length between outdoor unit and indoor unit is 90 m or more, size of main piping must be increased.: Not possible

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXXXXXX

XXXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXX

XXXX

XXXXXXXXXXXXXXXXXXXX

XXXXXXXXXX

XXX

XXXXXXXXXXXXXXXXXXXXX

XXXXXXXXXX

XXXXXXXXXXXXXXXXXXXXX

XXXXXXXXX

XXXXXXXXXXXXXXXXX

XXXXXXXX

XXX

XXXXXXXXXXXX

XXXXXXXX

XXXXXXXXX

XXXXXXXXX

XXXXXXXXX

XXXXXXXXXXXXXXX

XXXXXXXXX

XXXXXXXXX

XXXXXXXXXXXXXXXXXXX

XXXXXXX

XXXXXX

XXXXXXX

XXXXXXXX

XXXXXXXXXX

XXXXXXXXX

XXXXXXXXX

XXXXXXXXXXXXXXXX

XXXXXXX

XXXXXXXXXXXXXXXX

XXXXXXXXXX

X

6.4 9.5 12.7 15.9

Liquid

Piping size

Gas

19.1 22.2 12.7 15.9 19.1 22.2 25.4 28.6 34.9 41.3 54.1

Type of piping

Main piping

From REFNETto REFNET *1

From REFNETto indoor unit*2

Capacity

Reusability of existing piping for VRV IV Q seriesPiping limits for reuse of existing piping

XX

XX

XX

SSS

SSS

SSSS

S

SS

SSSSSSSSSSS

SSSSSSS

SSSSSS

SSSSSSS

SS

SS

SS

SS

S

SSS

SSSSS

SS

SS

SSS

SS

SS

SS

SS

SSSSS

SS

SS

S

S

a

i

s

r

hgf

edcb

*1 Piping between REFNETs depends on total capacity index of indoor units connected below each REFNET. It cannot exceed piping size of upstream side.*2 Piping from REFNET to indoor unit depends on the capacity of the connected indoor unit. It cannot exceed piping size of upstream side.

Max. 150 m

Actual piping length

Max. 175 m

Equivalent piping length

Max. 300 m

Total piping length

Guidelines for Reuse of Existing Refrigerant Piping

97 98

VR

V IV

Q S

erie

s

VRV IV Q Series

Floo

r St

andi

ngCe

iling

Susp

ende

dC

ateg

ory

Cei

ling

Mou

nted

Cas

sett

eC

eilin

g C

once

aled

Duc

t

Outdoor unit combinations

Outdoor Unit Lineup Indoor Unit Lineup

Enhanced lineup to 2 types Wide variety of indoor units

FXDSQ-AVM

FXSQ-PAVE

Capacity Range

Capacity Index 20

0.8 HP

20

1.6 HP

40

2.5 HP

63

3.2 HP

80

3 HP

71

4 HP

100

5 HP

125

6 HP

140

8 HP

200

10 HP

250

2 HP1.25 HP

32

62.531.25

1 HP

25

Type Model Name

FXFSQ-AVM

Ceiling Suspended

Wall Mounted

Floor Standing

Concealed Floor Standing

4-Way Flow Ceiling Suspended

Outdoor-Air Processing Unit

FXVQ-NY1

FXVQ-NY16(high static pressure type)

Floor Standing Duct

FXDQ-SPV1

400

16 HP

500

20 HP

FXMQ-MFV1

Heat Reclaim Ventilator

Heat Reclaim Ventilator with DX-Coil and Humidifier VKM-GA(M)V1

VAM-GJVE

Airflow rate 500-1000 m3/h

Airflow rate 150-2000 m3/h

FXEQ-AV36

FXFQ-AVM

FXCQ-AVM

FXMQ-PAVE

FXMQ-PVM

FXHQ-AVM

FXUQ-AVEB

FXHQ-MAVE

FXAQ-AVM

FXLQ-MAVE

FXNQ-MAVE

FXDQ-PDVE(with drain pump)

FXDQ-PDVET(without drain pump)

FXDQ-NDVE(with drain pump)

FXDQ-NDVET(without drain pump)

(700 mm width type)

(900/1,100 mm width type)

50

40 8071 100 125 140 200 25025 400 50050

Maximum number ofconnectable indoor units*2

Total capacity index of connectable indoor units*3

HP Combination

RQ(Y)Q18T

RQ(Y)Q20T

RQ(Y)Q12T + RQ(Y)Q18T

RQ(Y)Q12T + RQ(Y)Q20T

RQ(Y)Q16T + RQ(Y)Q18T

RQ(Y)Q18T x 2

RQ(Y)Q18T + RQ(Y)Q20T

RQ(Y)Q20T x 2

RQ(Y)Q12T x 2 + RQ(Y)Q18T

RQ(Y)Q12T x 2 + RQ(Y)Q20T

RQ(Y)Q12T + RQ(Y)Q16T + RQ(Y)Q18T

RQ(Y)Q12T + RQ(Y)Q18T x 2

225 to 585

250 to 650

375 to 975

400 to 1,040

425 to 1,105

450 to 1,170

475 to 1,235

500 to 1,300

525 to 1,365

550 to 1,430

575 to 1,495

600 to 1,560

Model name

RQ(Y)Q18T

RQ(Y)Q20T

RQ(Y)Q30TS

RQ(Y)Q32TS

RQ(Y)Q34TS

RQ(Y)Q36TS

RQ(Y)Q38TS

RQ(Y)Q40TS

RQ(Y)Q42TS

RQ(Y)Q44TS

RQ(Y)Q46TS

RQ(Y)Q48TS

18

20

30

32

34

36

38

40

42

44

46

48

29

32

48

52

55

58

61

64

Outdoor unit multi connection piping kit*1

BHFP22P151

BHFP22P100

Capacityindex

450

500

750

800

850

900

950

1,000

1,050

1,100

1,150

1,200Notes: *1. For multiple connection of 30 HP and above the outdoor unit multi connection piping kit (separately sold) is required.

*2. Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor units.*3. When outdoor-air processing units and standard indoor units are connected, the total connection capacity index of the outdoor-air processing units

must not exceed 30% of the capacity index of the outdoor units. And the connection ratio must not exceed 100%.

kW

50.0

56.0

83.5

89.5

95.0

100

106

112

117

123

129

134

Standard Type

Space Saving Type

200

150 —

100 to 260

75 to 195

13

9

250 — 125 to 325 16

300 — 150 to 390 19

350 — 175 to 455 22

400 — 200 to 520 26

450 225 to 585 29

500 250 to 650 32

550 275 to 715 35

600 BHFP22P100

300 to 780 39

650 325 to 845 42

700 350 to 910 45

750 375 to 975 48

800 400 to 1,040 52

850 425 to 1,105 55

900 450 to 1,170 58

950 475 to 1,235 61

64

1,000 500 to 1,300

1,050 525 to 1,365

1,100 550 to 1,430

1,150

BHFP22P151

575 to 1,495

1,200 600 to 1,560

Notes: *1. For multiple connection of 18 HP systems and above, the outdoor unit multi connection piping kit (separately sold) is required.*2. Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outdoor units.*3. When outdoor-air processing units and standard indoor units are connected, the total connection capacity index of the outdoor-air processing units

must not exceed 30% of the capacity index of the outdoor units. And the connection ratio must not exceed 100%.

Capacity indexHP Model name Combination Outdoor unit multi

connection piping kit*1Total capacity index of

connectable indoor units*3Maximum number of

connectable indoor units*2

8

6

10

12

14

16

18

20

22

24

26

28

30

32

34

36

38

40

42

44

46

48

22.4

16.0

28.0

33.5

40.0

45.0

50.4

55.9

61.5

67.0

73.5

78.5

85.0

90.0

95.0

101

106

112

119

124

130

135

kW

RQ(Y)Q6T

RQ(Y)Q8T

RQ(Y)Q10T

RQ(Y)Q12T

RQ(Y)Q14T

RQ(Y)Q16T

RQ(Y)Q18TN

RQ(Y)Q20TN

RQ(Y)Q22TN

RQ(Y)Q24TN

RQ(Y)Q26TN

RQ(Y)Q28TN

RQ(Y)Q30TN

RQ(Y)Q32TN

RQ(Y)Q34TN

RQ(Y)Q36TN

RQ(Y)Q38TN

RQ(Y)Q40TN

RQ(Y)Q42TN

RQ(Y)Q44TN

RQ(Y)Q46TN

RQ(Y)Q48TN

RQ(Y)Q6T

RQ(Y)Q8T

RQ(Y)Q10T

RQ(Y)Q12T

RQ(Y)Q14T

RQ(Y)Q16T

RQ(Y)Q8T + RQ(Y)Q10T

RQ(Y)Q8T + RQ(Y)Q12T

RQ(Y)Q10T + RQ(Y)Q12T

RQ(Y)Q12T × 2

RQ(Y)Q12T + RQ(Y)Q14T

RQ(Y)Q12T + RQ(Y)Q16T

RQ(Y)Q14T + RQ(Y)Q16T

RQ(Y)Q14T + RQ(Y)Q18T

RQ(Y)Q10T + RQ(Y)Q12T × 2

RQ(Y)Q12T × 3

RQ(Y)Q8T + RQ(Y)Q12T + RQ(Y)Q18T

RQ(Y)Q12T × 2 + RQ(Y)Q16T

RQ(Y)Q12T + RQ(Y)Q14T + RQ(Y)Q16T

RQ(Y)Q12T + RQ(Y)Q16T × 2

RQ(Y)Q14T × 2 + RQ(Y)Q18T

RQ(Y)Q14T + RQ(Y)Q16T + RQ(Y)Q18T

Lineup

FXZQ-AVM

VRV IV Q Series

New lineup

3D Airflow Duct with Sensing

Middle Static Pressure Duct

Round Flow Cassette with Sensing

Round Flow Cassette

Compact Multi Flow Cassette

Double Flow Cassette

Single Flow Cassette

Slim Duct (Standard)

Middle-High Static Pressure Duct

High Static Pressure Duct

Slim Duct (Compact)

HP

Standard TypeVRV IV Q Series Space Saving Type

6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48

99 100

VR

V IV

Q S

erie

s

VRV IV Q Series

Outdoor Units

Specifications

Standard Type

172,000

50.4

12.1

191,000

55.9

14.0

210,000

61.5

15.7

229,000

67.0

17.6

251,000

73.5

19.5

268,000

78.5

21.8

290,000

85.0

23.7

RQQ10TYM(E)

RQQ12TYM(E)

RQQ8TYM(E)

RQQ12TYM(E)

RQQ8TYM(E)

RQQ10TYM(E)

RQQ22TNYM(E) RQQ24TNYM(E) RQQ26TNYM(E) RQQ28TNYM(E) RQQ30TNYM(E)RQQ18TNYM(E) RQQ20TNYM(E)

(3.4X1)+(4.1X1)

(3.4X1)+(5.2X1)

(1,657X930X765)+(1,657X930X765) (1,657X930X765)+(1,657X1,240X765) (1,657X1,240X765)+(1,657X1,240X765)

60

5.9+6.0 5.9+6.3 6.0+6.3

62

6.3+6.3 6.3+10.3 6.3+10.4 10.3+10.4

RQQ12TYM(E)

RQQ12TYM(E)

RQQ12TYM(E)

RQQ14TYM(E)

RQQ12TYM(E)

RQQ16TYM(E)

RQQ14TYM(E)

RQQ16TYM(E)

(5.2X1)+(5.2X1)

(4.1X1)+(5.2X1)

(5.2X1)+(2.9X1)+(3.3X1)

157+165 157+178 165+178 178+178 178+233 233+233

(5.2X1)+(3.6X1)+(3.7X1)

(2.9X1)+(3.3X1)+(3.6X1)+(3.7X1)

15.9(Brazing)

19.1(Brazing)

Hermetically Sealed Scroll Type

— — — —— — —

Ivory white (5Y7.5/1)

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

-5 to 49

R-410A

RQQ14TYM(E)

RQQ18TYM(E)

RQQ32TNYM(E)

307,000

90.0

26.1

285+285

64

(2.9X1)+(3.3X1)+(4.4X1)+(4.0X1)

RQQ6TYM(E) RQQ8TYM(E) RQQ10TYM(E) RQQ12TYM(E) RQQ14TYM(E) RQQ16TYM(E)

54,600

16.0

3.63

76,400

22.4

5.18

95,500

28.0

6.88

16-100

114,000

33.5

8.82

15-100

136,000

40.0

10.7

11-100

154,000

45.0

13.0

10-100

55 56 57

6.0

59

6.3

60

10.3

61

10.4

2.4X1 3.4X1 4.1X1 5.2X1

119 157 165 178 233 233

(2.9X1)+(3.3X1) (3.6X1)+(3.7X1)

1,657X930X765 1,657X1,240X765

Hermetically Sealed Scroll Type

12.7(Brazing) 19.1(Brazing)

9.5(Brazing)

22.2(Brazing)

-5 to 49

R-410A

— — — — — —

Ivory white (5Y7.5/1)

MODEL

Power supply

Power consumption

Capacity control

Compressor

Dimensions (H×W×D)

Machine weight

Sound level

Refrigerant

Pipingconnections

Btu/h

kW

kW

%

kg

dB(A)

ºCDB

kg

kW

m³/min

mm

Charge

Type

Type

Liquid

Gas

mm

mm

Combination units

Cooling capacity

Motor output

Airflow rate

Operation range

Casing colour

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

28.6(Brazing) 28.6(Brazing) 34.9(Brazing)

Hermetically Sealed Scroll Type

Ivory white (5Y7.5/1)

RQQ14TYM(E)

RQQ14TYM(E)

RQQ18TYM(E)

RQQ46TNYM(E)

(2.9X1)+(3.3X1)+(2.9X1)+(3.3X1)+(4.4X1)+(4.0X1)

444,000

130

36.8

(1,657X1,240X765)+(1,657X1,240X765)+(1,657X1,240X765)

10.3+10.3+10.5

233+233+233

19.1(Brazing)

-5 to 49

R-410A

461,000

135

39.1

RQQ14TYM(E)

RQQ16TYM(E)

RQQ18TYM(E)

RQQ48TNYM(E)

10.3+10.4+10.5

(2.9X1)+(3.3X1)+(3.6X1)+(3.7X1)+(4.4X1)+(4.0X1)

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

RQQ10TYM(E)

RQQ12TYM(E)

RQQ12TYM(E)

RQQ12TYM(E)

RQQ12TYM(E)

RQQ12TYM(E)

RQQ8TYM(E)

RQQ12TYM(E)

RQQ18TYM(E)

RQQ12TYM(E)

RQQ12TYM(E)

RQQ16TYM(E)

RQQ12TYM(E)

RQQ14TYM(E)

RQQ16TYM(E)

RQQ12TYM(E)

RQQ16TYM(E)

RQQ16TYM(E)

RQQ34TNYM(E) RQQ36TNYM(E) RQQ38TNYM(E) RQQ40TNYM(E) RQQ42TNYM(E) RQQ44TNYM(E)

324,000

95.0

24.5

(1,657X930X765)+(1,657X930X765)+(1,657X930X765)

195+195+195

63

6.0+6.3+6.3

165+178+178

345,000

101

26.5

195+195+195

6.3+6.3+6.3

178+178+178

362,000

106

29.4

(1,657X930X765)+(1,657X930X765)+(1,657X1,240X765)

185+195+285

5.9+6.3+10.5

157+178+233

382,000

112

30.6

195+195+285

6.3+6.3+10.4

(5.2X1)+(5.2X1)+(3.6X1)+(3.7X1)

(3.4X1)+(5.2X1)+(4.4X1)+(4.0X1)

(4.1X1)+(5.2X1)+(5.2X1)

(5.2X1)+(5.2X1)+(5.2X1)

(5.2X1)+(3.6X1)+(3.7X1)+(3.6X1)+

(3.7X1)

(5.2X1)+(2.9X1)+(3.3X1)+(3.6X1)+

(3.7X1)

178+178+233

406,000

119

32.5

(1,657X930X765)+(1,657X1,240X765)+(1,657X1,240X765)

6.3+10.3+10.4

423,000

124

34.8

6.3+10.4+10.4

178+233+233

19.1(Brazing)

Hermetically Sealed Scroll Type

Ivory white (5Y7.5/1)

MODEL

Power supply

Power consumption

Capacity control

Compressor

Dimensions (H×W×D)

Machine weight

Sound level

Refrigerant

Pipingconnections

Btu/h

kW

kW

%

kg

dB(A)

ºCDB

kg

kW

m³/min

mm

Charge

Type

Type

Liquid

Gas

mm

mm

Combination units

Cooling capacity

Motor output

Airflow rate

Operation range

Casing colour

-5 to 49

R-410A

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

34.9(Brazing) 41.3(Brazing) 41.3(Brazing)

RQQ18TYM(E) RQQ20TYM(E)

233

171,000

50.0

15.4

10-100

1,657X1,240X765

285

62

10.5

191,000

56.0

18.0

8-100

320

65

11.8

268

(4.6X1)+(5.5X1)(4.4X1)+(4.0X1)

15.9(Brazing)

Hermetically Sealed Scroll Type

— —

MODEL

Power supply

Power consumption

Capacity control

Compressor

Dimensions (H×W×D)

Machine weight

Sound level

Refrigerant

Pipingconnections

Btu/h

kW

kW

%

kg

dB(A)

ºCDB

kg

kW

m³/min

mm

Charge

Type

Type

Liquid

Gas

mm

mm

Combination units

Cooling capacity

Motor output

Airflow rate

Operation range

Ivory white (5Y7.5/1)Casing colour

-5 to 49

R-410A

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

28.6(Brazing)

20-100

185 195 285

5.9

8-100 6-100 5-100

10.3+10.5

61 63

185+195 195+195 195+285

5-100 4-100 3-100

6564

195+285+285 285+285+285

66

Space Saving Type

Notes: 1. Models with (E) are the outdoor units with anti-corrosion specifications. Please refer to Engineering Data Book for details. 2. Specifications are based on the following conditions;

• Cooling: Indoor temp.: 27° CDB, 19° CWB, Outdoor temp.: 35° CDB, E quivalent piping length: 7.5 m, Level difference: 0 m.• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. When there is concern for noise to the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

Cooling Only

VRV IV Q Series

101 102

VR

V IV

Q S

erie

s

VRV IV Q Series

Outdoor Units

Specifications

VRV IV Q Series

233+268

362,000

106

33.4

(1,657×1,240×765)+(1,657×1,240×765)

285+320

67

10.5+11.8

382,000

112

36.0

320+320

68

11.8+11.8

268+268

399,000

117

33.0

(1,657×930×765)+(1,657×930×765)+(1,657×1,240×765)

195+195+285

65

6.3+6.3+10.5

178+178+233

420,000

123

35.6

195+195+320

67

6.3+6.3+11.8

(5.2×1)+(5.2×1)+(4.6×1)+(5.5×1)

(5.2×1)+(5.2×1)+(4.4×1)+(4.0×1)

(4.6×1)+(5.5×1)+(4.6×1)+(5.5×1)

(4.4×1)+(4.0×1)+(4.6×1)+(5.5×1)

(5.2×1)+(4.4×1)+(4.0×1)+(4.4×1)+(4.0×1)

(5.2×1)+(3.6×1)+(3.7×1)+(4.4X1)+(4.0×1)

178+178+268

440,000

129

37.2

(1,657×930×765)+(1,657×1,240×765)+(1,657×1,240×765)

6.3+10.4+10.5

457,000

134

39.6

6.3+10.5+10.5

178+233+233

19.1(Brazing)

41.3(Brazing)

Hermetically Sealed Scroll Type

-5 to 49

R-410A

— —

Ivory white (5Y7.5/1)

RQQ20TYM(E)

RQQ20TYM(E)

RQQ12TYM(E)

RQQ12TYM(E)

RQQ18TYM(E)

RQQ12TYM(E)

RQQ12TYM(E)

RQQ20TYM(E)

RQQ12TYM(E)

RQQ16TYM(E)

RQQ18TYM(E)

RQQ12TYM(E)

RQQ18TYM(E)

RQQ18TYM(E)

RQQ18TYM(E)

RQQ20TYM(E)

RQQ38TSYM(E) RQQ40TSYM(E) RQQ42TSYM(E) RQQ44TSYM(E) RQQ46TSYM(E) RQQ48TSYM(E)

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

285,000

83.5

24.2

6-100

305,000

89.5

26.8

324,000

95.0

28.4

5-100

341,000

100

30.8

(1,657×930X765)+(1,657×1,240X765) (1,657×1,240×765)+(1,657×1,240×765)

195+285

64

6.3+10.5

195+320

66

6.3+11.8 10.4+10.5 10.5+10.5

178+233 178+268 233+233

(3.6×1)+(3.7×1)+(4.4×1)+(4.0×1)

(5.2×1)+(4.6×1)+(5.5×1)

(5.2×1)+(4.4×1)+(4.0×1)

(4.4×1)+(4.0×1)+(4.4×1)+(4.0×1)

34.9(Brazing)

41.3(Brazing)

Hermetically Sealed Scroll Type

-5 to 49

R-410A

— — — —

Ivory white (5Y7.5/1)

MODEL

Power supply

Power consumption

Capacity control

Compressor

Dimensions (H×W×D)

Machine weight

Sound level

Refrigerant

Pipingconnections

Btu/h

kW

kW

%

kg

dB(A)

ºCDB

kg

kW

m³/min

mm

Charge

Type

Type

Liquid

Gas

mm

mm

Combination units

Cooling capacity

Motor output

Airflow rate

Operation range

Casing colour

RQQ30TSYM(E) RQQ32TSYM(E) RQQ34TSYM(E) RQQ36TSYM(E)

RQQ12TYM(E)

RQQ18TYM(E)

RQQ12TYM(E)

RQQ20TYM(E)

RQQ16TYM(E)

RQQ18TYM(E)

RQQ18TYM(E)

RQQ18TYM(E)

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

RQYQ6TY1(E) RQYQ8TY1(E) RQYQ10TY1(E) RQYQ12TY1(E) RQYQ14TY1(E) RQYQ16TY1(E)

54,60016.0

61,40018.03.633.99

76,40022.4

85,30025.05.185.69

95,50028.0

107,00031.56.887.29

16-100

114,00033.5

128,00037.58.829.06

15-100

136,00040.0

154,00045.010.711.1

11-100

154,00045.0

171,00050.013.012.8

10-100

55 56 57

6.0

59

6.3

60

10.3

61

10.4

2.4×1 3.4×1 4.1×1 5.2×1

119 157 165 178 233

(2.9×1)+(3.3×1) (3.6×1)+(3.7×1)

1,657X930X765 1,657X1,240X765

3-phase 4-wire system, 380-415 V, 50 Hz

Hermetically Sealed Scroll Type

12.7(Brazing) 19.1(Brazing)

9.5(Brazing) 22.2(Brazing) 28.6(Brazing)

-5 to 49-20 to 15.5

R-410A

Ivory white (5Y7.5/1)

MODEL

Power supply

Powerconsumption

Capacity control

Compressor

Dimensions (H×W×D)

Machine weight

Sound level

Refrigerant

Pipingconnections

Btu/h

kW

Btu/h

kW

kW

kW

%

kg

dB(A)

ºCDB

ºCWB

kg

kW

m³/min

mm

Charge

Type

Type

Liquid

Gas

mm

mm

Combination units

Cooling capacity

Heating capacity

Motor output

Airflow rate

Operationrange

Cooling

Heating

Cooling

Heating

Casing colour

— — — — — —RQYQ8TY1(E)

RQYQ12TY1(E)

RQYQ10TY1(E)

RQYQ12TY1(E)

RQYQ12TY1(E)

RQYQ12TY1(E)

RQYQ12TY1(E)

RQYQ14TY1(E)

RQYQ12TY1(E)

RQYQ16TY1(E)

RQYQ14TY1(E)

RQYQ16TY1(E)

RQYQ14TY1(E)

RQYQ18TY1(E)

RQYQ8TY1(E)

RQYQ10TY1(E)

RQYQ18TNY1(E) RQYQ20TNY1(E) RQYQ22TNY1(E) RQYQ24TNY1(E) RQYQ26TNY1(E) RQYQ28TNY1(E) RQYQ30TNY1(E) RQYQ32TNY1(E)

3-phase 4-wire system, 380-415 V, 50 Hz

Hermetically Sealed Scroll Type

-5 to 49-20 to 15.5

R-410A

— — — — — — — —

Ivory white (5Y7.5/1)

172,00050.4

193,00056.512.113.0

191,00055.9

213,00062.514.014.8

(3.4×1)+(4.1×1)

(3.4×1)+(5.2×1)

(1,657×930×765)+(1,657×930×765)

60

5.9+6.0 5.9+6.3

157+165 157+178

15.9(Brazing) 28.6(Brazing)

210,00061.5

235,00069.015.716.4

6.0+6.3

165+178

229,00067.0

256,00075.017.618.1

62

6.3+6.3

178+178

(5.2×1)+(5.2×1)

(4.1×1)+(5.2×1)

251,00073.5

281,00082.519.520.2

6.3+10.3

(5.2×1)+(2.9×1)+(3.3×1)

268,00078.5

299,00087.521.821.9

(1,657×930×765)+(1,657×1,240×765)

6.3+10.4

178+233

(5.2×1)+(3.6×1)+(3.7×1)

34.9(Brazing)

290,00085.0

324,00095.023.723.9

(1,657×1,240×765)+(1,657×1,240×765)285+285

10.3+10.4

(2.9×1)+(3.3×1)+(3.6×1)+(3.7×1)

19.1(Brazing)

233+233

307,00090.0

345,00010126.126.2

285+300

10.3+11.7

(2.9×1)+(3.3×1)+(4.4×1)+(4.0×1)

Space Saving Type

285+285

65

19.1(Brazing)

4-100

20-100

285185 195

5.9

5-1006-1008-100

185+19561

195+195 195+28563 64

• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. When there is concern for noise to the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

195+285+285

66

Standard Type

Notes: 1. Models with (E) are the outdoor units with anti-corrosion specifications. Please refer to Engineering Data Book for details. 2. Specifications are based on the following conditions;

• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.

Heat Pump

Cooling Only

103 104

VR

V IV

Q S

erie

s

VRV IV Q Series

Outdoor Units

Specifications

VRV IV Q Series

• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. When there is concern for noise to the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

RQYQ10TY1(E)RQYQ12TY1(E)RQYQ12TY1(E)

RQYQ12TY1(E)RQYQ12TY1(E)RQYQ12TY1(E)

RQYQ8TY1(E)RQYQ12TY1(E)RQYQ18TY1(E)

RQYQ12TY1(E)RQYQ12TY1(E)RQYQ16TY1(E)

RQYQ12TY1(E)RQYQ14TY1(E)RQYQ16TY1(E)

RQYQ12TY1(E)RQYQ16TY1(E)RQYQ16TY1(E)

RQYQ34TNY1(E) RQYQ36TNY1(E) RQYQ38TNY1(E) RQYQ40TNY1(E) RQYQ42TNY1(E) RQYQ44TNY1(E)MODEL

Power supply

Powerconsumption

Capacity control

Compressor

Dimensions (H×W×D)

Machine weight

Sound level

Refrigerant

Pipingconnections

Btu/h

kW

Btu/h

kW

kW

kW

%

kg

dB(A)

ºCDB

ºCWB

kg

kW

m³/min

mm

Charge

Type

Type

Liquid

Gas

mm

mm

Combination units

Cooling capacity

Heating capacity

Motor output

Airflow rate

Operationrange

Cooling

Heating

Cooling

Heating

Casing colour

RQYQ14TY1(E)RQYQ14TY1(E)RQYQ18TY1(E)

RQYQ46TNY1(E)RQYQ14TY1(E)RQYQ16TY1(E)RQYQ18TY1(E)

RQYQ48TNY1(E)

324,00095.0

365,00010724.525.4

(1,657×930×765)+(1,657×930×765)+(1,657×930×765)

63

165+178+178

345,000101

386,00011326.527.2

178+178+178

362,000106

406,00011929.429.9

185+195+300

5.9+6.3+11.7

157+178+233

382,000112

427,00012530.630.9

(1,657×930×765)+(1,657×930×765)+(1,657×1,240×765)

195+195+285

6.3+6.3+10.4

(5.2×1)+(5.2×1)+(3.6×1)+(3.7×1)

(3.4×1)+(5.2×1)+(4.4×1)+(4.0×1)

(4.1×1)+(5.2×1)+(5.2×1)

(5.2×1)+(5.2×1)+(5.2×1)

(2.9×1)+(3.3×1)+(2.9×1)+(3.3×1)+(4.4×1)+(4.0×1)

(5.2×1)+(3.6×1)+(3.7×1)+(3.6×1)+

(3.7×1)

(5.2×1)+(2.9×1)+(3.3×1)+(3.6×1)+

(3.7×1)

178+178+233

406,000119

454,00013332.533.0

6.3+10.3+10.4

178+233+233

423,000124

471,00013834.834.7

(1,657×930×765)+(1,657×1,240×765)+(1,657×1,240×765)

6.3+10.4+10.4

444,000130

498,00014636.837.3

(1,657×1,240×765)+(1,657×1,240×765)+(1,657×1,240×765)

10.3+10.3+11.7

233+233+233

34.9(Brazing) 19.1(Brazing)

3-phase 4-wire system, 380-415 V, 50 Hz 3-phase 4-wire system, 380-415 V, 50 Hz

Hermetically Sealed Scroll Type

-5 to 49-20 to 15.5

R-410A

Ivory white (5Y7.5/1)Hermetically Sealed Scroll Type

-5 to 49-20 to 15.5

R-410A

Ivory white (5Y7.5/1)

461,000135

515,00015139.139.0

10.3+10.4+11.7

(2.9×1)+(3.3×1)+(3.6×1)+(3.7×1)+(4.4×1)+(4.0×1)

Standard Type

— — — — — —

RQYQ20TY1(E)RQYQ20TY1(E)

RQYQ12TY1(E)RQYQ12TY1(E)RQYQ18TY1(E)

RQYQ12TY1(E)RQYQ12TY1(E)RQYQ20TY1(E)

RQYQ12TY1(E)RQYQ16TY1(E)RQYQ18TY1(E)

RQYQ12TY1(E)RQYQ18TY1(E)RQYQ18TY1(E)

RQYQ30TSY1(E) RQYQ32TSY1(E) RQYQ34TSY1(E) RQYQ36TSY1(E)RQYQ12TY1(E)RQYQ18TY1(E)

RQYQ12TY1(E)RQYQ20TY1(E)

RQYQ16TY1(E)RQYQ18TY1(E)

RQYQ18TY1(E)RQYQ18TY1(E)

RQYQ18TY1(E)RQYQ20TY1(E)

RQYQ38TSY1(E) RQYQ40TSY1(E) RQYQ42TSY1(E) RQYQ44TSY1(E) RQYQ46TSY1(E) RQYQ48TSY1(E)MODEL

Power supply

Powerconsumption

Capacity control

Compressor

Dimensions (H×W×D)

Machine weight

Sound level

Refrigerant

Pipingconnections

Btu/h

kW

Btu/h

kW

kW

kW

%

kg

dB(A)

ºCDB

ºCWB

kg

kW

m³/min

mm

Charge

Type

Type

Liquid

Gas

mm

mm

Combination units

Cooling capacity

Heating capacity

Motor output

Airflow rate

Operationrange

Cooling

Heating

Cooling

Heating

Casing colour

285,00083.5

319,00093.524.224.2

6-100

305,00089.5

345,00010126.826.6

324,00095.0

362,00010628.427.9

5-100

341,000100

382,00011230.830.2

(1,657×930×765)+(1,657×1,240×765) (1,657×1,240×765)+(1,657×1,240×765)

195+32066

6.3+11.8

285+300

10.4+11.7

300+300

11.7+11.7

178+233 178+268 233+233 233+268

362,000106

406,00011933.432.6

(1,657×1,240×765)+(1,657×1,240×765)

300+32067

11.7+11.8

382,000

112430,000

12636.035.0

320+32068

11.8+11.8

268+268

399,000117

447,00013133.033.2

(1,657×930×765)+(1,657×930×765)+(1,657×1,240×765)

195+195+30065

6.3+6.3+11.7

178+178+233

420,000123

471,00013835.635.6

195+195+32067

6.3+6.3+11.8

(5.2×1)+(5.2×1)+(4.6×1)+(5.5×1)

(5.2×1)+(5.2×1)+(4.4×1)+(4.0×1)

(4.6×1)+(5.5×1)+(4.6×1)+(5.5×1)

(4.4×1)+(4.0×1)+(4.6×1)+(5.5×1)

(5.2×1)+(4.4×1)+(4.0×1)+(4.4×1)+(4.0×1)

(5.2×1)+(3.6×1)+(3.7×1)+(4.4×1)+(4.0×1)

178+178+268

440,000

129491,000

14437.237.0

(1,657×930×765)+(1,657×1,240×765)+(1,657×1,240×765)

195+285+300

6.3+10.4+11.7

178+233+233

457,000134

512,00015039.639.3

195+300+300

6.3+11.7+11.7

(3.6×1)+(3.7×1)+(4.4×1)+(4.0×1)

(5.2×1)+(4.6×1)+(5.5×1)

(5.2×1)+(4.4×1)+(4.0×1)

(4.4×1)+(4.0×1)+(4.4×1)+(4.0×1)

19.1(Brazing) 41.3(Brazing)

19.1(Brazing) 34.9(Brazing) 41.3(Brazing)

3-phase 4-wire system, 380-415 V, 50 Hz

Hermetically Sealed Scroll Type

-5 to 49-20 to 15.5

R-410A

3-phase 4-wire system, 380-415 V, 50 Hz

Hermetically Sealed Scroll Type

-5 to 49-20 to 15.5

R-410A

Ivory white (5Y7.5/1) Ivory white (5Y7.5/1)

195+30064

6.3+11.7

Space Saving Type

MODEL

Power supply

Powerconsumption

Capacity control

Compressor

Dimensions (H×W×D)

Machine weight

Sound level

Refrigerant

Pipingconnections

Btu/h

kW

Btu/h

kW

kW

kW

%

kg

dB(A)

ºCDB

ºCWB

kg

kW

m³/min

mm

Charge

Type

Type

LiquidGas

mmmm

Combination units

Cooling capacity

Heating capacity

Motor output

Airflow rate

Operationrange

Cooling

Heating

Cooling

Heating

Casing colour

RQYQ18TY1(E) RQYQ20TY1(E)

––

233

171,00050.0

191,00056.015.415.1

10-100

1,657×1,240×765

30062

11.7

191,00056.0

215,00063.018.017.5

8-100

32065

11.8

268

(4.6×1)+(5.5×1)(4.4×1)+(4.0×1)

15.9(Brazing) 28.6(Brazing)

3-phase 4-wire system, 380-415 V, 50 Hz

-5 to 49-20 to 15.5

R-410A

Ivory white (5Y7.5/1)

41.3(Brazing)

3-1004-1005-100

64195+195+195 285+285+300

66195+285+285

65

6.0+6.3+6.3

65

4-100

66

Hermetically Sealed Scroll Type

Notes: 1. Models with (E) are the outdoor units with anti-corrosion specifications. Please refer to Engineering Data Book for details. 2. Specifications are based on the following conditions;

• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.

Heat Pump

105 106

VR

V IV

W S

erie

s

VRV IV W Series

Cooling tower (closed type)

Outside unit

Indoor unitRefrigerant piping

Water piping

Boiler (for heating)

High-rise buildings Condominiums and detached houses

Underground shopping malls and subway

• Water cooled system does not require to exchange heat with outdoor air

Design flexibility

Design flexibilityHigh installation

flexibility

Compact outside units can be easily installed in the machine rooms on each floor. It is adaptable to high-rise buildings.

We offer an extensive lineup of small capacity outside units as well as connectable residential indoor units.

As heat exchanging with outdoor air is not required, individual air conditioning can be easily provided.

• Individual air conditioning is achieved via on-demand operation in each room.

• The length of the refrigerant piping can be minimized by installing outside units in proximity to indoor units.

• As refrigerant piping is connected to indoor units, it reduces the risks of indoor water leakage.

• Outside units can be installed indoors.• The air conditioning operation is stable even

when the outdoor air temperature is high

Water Cooled System Suitable for Tall Multi-Storied Buildings

Single outdoor units

RWEYQ6-12TYM

Double outdoor units

RWEYQ14-24TYM

Triple outdoor units

RWEYQ26-36TYM

6HP–36HP

Heat Pump

(16 kW) (101 kW)

No balcony required

Drain pipe

Water pipeWater pipe

(300-400 mm)

* Only for the purpose of illustration.

Min. 300 mm

(100-300 mm)

Refrigerant liquid pipeRefrigerant gas pipe

Water in�owWater out�ow

Celling heightMin. 3,200 mm

107 108

VR

V IV

W S

erie

s

VRV IV W Series

Based on cooling condition

OfficeMeeting room

Large meeting room: OFF

General manager office: 27°C, low air volume

Office: 26°C, high air volume

Phase 1

Phase 2

Phase 3

*System diagram

Water cooled VRV IV W series

Renovation in phases is possible.

Easy Installation

It is possible to place the outside unit inside the building, it makes easier to adapt to different type of buildings and open to various kinds of creative building exteriors.

Indoor installation solves the puzzle of proper placement of outdoor units

The water cooled VRV IV W series can retain the cooling tower and boiler of the old system during renovation, effectively keeping costs down.

Part of the old system can be retained

• The outside units are conveniently compact so transport by elevator is possible. It also effectively simplifies installation. This also saves a great deal of time and labor.

• The modular design enables a free and flexible configuration of the outside units. Also can save space for other purposes.

The compact outside units facilitate the renovation process

Because equipment can be replaced in phases, installation adapts to the renovation plans of the customers and ensures that work performed on some floors and zones will not affect other tenants.

Floor by floor renovation without disturbing other tenants

During actual operation, the load of an air conditioning system changes according to variations in weather conditions outside and indoor unit operation rates. Daikin’s advanced DC inverter technology and advanced refrigerant control technology boasts a higher efficiency under partial load than in the rated operating conditions.

Higher efficiency with partial load

Each indoor unit can be independently controlled and adjusted according to each tenant’s individual needs for temperature and air volume.

Independent control provides greater comfort and convenience.

Each indoor unit can be independently controlled and adjusted according to each tenant’s individual needs for temperature and air volume.

• Inconvenient transportation procedures are eliminated.• Operation for each indoor unit can be precisely and individually set.

Flexibly satisfies conditions for working overtime and times of insufficient load

Water Cooled VRV IV as a Retrofit Solution

Problems with existing water systems can be solved with minimal construction work.

Individual air conditioning comfort can be realized when and where it is actually required.

A flexible system convenient for expansion/renovation

Actual conditions of the floor

Air conditioning of the meetingroom is normally switched off

Example of air conditioning control for different rooms of the same floor

Cost Saving

Space Saving

Flexible Renovation

Saving morespace for

other purposes

Outside units take up a disproportionately large amount of

space for installation.Can save space

Retained coolingtower

Retained boiler

Before renovation After renovation*System diagram

Cooling tower

Garage

Cooling tower

Cold sourceback-flow

Cold sourcesupply

Heat source supply

Heat source back-flow

Cooling tower

Pump

Pump

BoilerPlate heat exchanger

During normal work hours, the building's central air conditioner is usedDuring normal work hours, the building's central air conditioner is used

At weekends, the water cooled VRV IV W series operatesAt weekends, the water cooled VRV IV W series operates

The water cooled VRV IV W series is utilised to meet overtime work needsThe water cooled VRV IV W series is utilised to meet overtime work needs

The water cooled VRV IV W series is utilised to meet weekend work needsThe water cooled VRV IV W series is utilised to meet weekend work needs

When a large number of people are present, the water cooled VRV IV W series can work to supplement insufficient capacity of the building's central air conditioner

When a large number of people are present, the water cooled VRV IV W series can work to supplement insufficient capacity of the building's central air conditioner

Both the building's central air conditionerand the water cooled VRV IV W series operate

Both the building's central air conditionerand the water cooled VRV IV W series operate

During overtime hours, the water cooled

VRV IV W series operates

During overtime hours, the water cooled

VRV IV W series operates

Meeting Room

WorkdaysOffice

WeekendsGeneral manager's office

8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 19:0018:00 20:00 21:00

109 110

VR

V IV

W S

erie

s

VRV IV W Series

Centralised interlocking function

Centralised interlocking input operate by using an external control adaptor (DTA104A62).

Easy Installation & Energy Saving

Compact and lightweight

Enhanced usability

Enhanced lineup

VRT control for optimal annual efficiency

VRT automatically adjusts refrigerant temperature to individual building and climate requirement, thus further improving annual energy efficiency and maintaining comfort.

Energy saving

*Cooling : Indoor temp.: 27ºCDB, 19ºCWB/inlet water temp.: 30ºC, Equivalent piping length: 7.5 m, Level difference: 0 m.

Cooling Operation EER

6.20

8 HP 10 HP 12 HP6 HP

5.805.16

4.57

6.00

5.00

4.00

3.00

2.00

1.00

0

6 HP, 8 HP, 10 HP, 12 HP

RWEYQ6TYMRWEYQ8TYM

RWEYQ14TYMRWEYQ16TYMRWEYQ18TYM

RWEYQ26TYMRWEYQ28TYMRWEYQ30TYM

RWEYQ20TYMRWEYQ22TYMRWEYQ24TYM

RWEYQ32TYMRWEYQ34TYMRWEYQ36TYM

RWEYQ10TYMRWEYQ12TYM

DTA104A62

CompactDesign

VRV III W series

VRV IV W Series

Higher Energy Efficiency Ratio (EER)

16%Increase

18%Increase

6, 8, 10, 12 HP 14, 16, 18, 20, 22, 24 HP 26, 28, 30, 32, 34, 36 HP

1,000 mm

780 mm

550 mm

Footprint : 0.43 m2

Product Weight :(*For 6 HP, 8 HP)146 kg

Wider capacity range from 6 to 36 HP

Interlocking

Control wiring(external-to-external transmission wiring)

Using one external control adaptor circuit board makes centralised interlocking input to multiple units within the same water system possible.

111 112

VR

V IV

W S

erie

s

VRV IV W Series

Installation for VRV indoor units only

Flexible System Design

Long piping length

Installation for residential indoor units only

*1 No special requirements up to 40 m. The maximum actual piping length can be 90 m, depending on conditions. The VRV IV W series is easy to extend to 90 m bylessening the conditions from conventional VRV III W models. Be sure to refer to the Engineering Data Book for details of these conditions and requirements.

p

q

k

fa

b

Firstindoor branch

Multiple use

Max.allowablelevel difference

Max.allowablepiping length

Between the outside units and the indoor units

Between the indoor units

Between the outside units (multiple use)

Between the first indoor branch and the farthest indoor unit

Between the first outside branch and the last outside unit

Total piping length

Refrigerant piping length

15 m

50 m

2 m

——

q

s

rIf the outside unit is above.If the outside unit is below. 40 m —r

a+b+c+d+e+f+g+h+i

a+f+g+h+i

f+g+h+i

k+p

120 m 140 m

300 m90 m*1

10 m 13 m

Actualpiping length

Equivalentpiping length Example

*1. When the piping length exceeds 20 m, the size of the main pipes (the gas side and the liquid side) must be increased. Please refer to Engineering Data Book for details.

Max.allowablelevel difference

Max.allowablepiping length

Max. and min.allowablepiping length

If indoor unit capacity index < 60

If indoor unit capacity index is 60

If indoor unit capacity index is 71

If the outside unit is above.

If the outside unit is below.

a+b+k

a+b+e+h+j+k

b+k

h,i,j,k

h,i,j,k

h,i,j,k

n

n

l

o

m

p

100 m

200 m

50 m*1

2 m - 15 m

2 m - 12 m

2 m - 8 m

50 m

40 m

15 m

40 m

15 m

5 m

120 m

Refrigerant piping length

Total piping length

Between the first indoor branch and the farthest indoor unit

Between the outside unit

and the indoor unit

Between the indoor units

Between the outside unit and the BP unit

Between BP units

Between the BP unit and the indoor unit

Actualpiping length

EquivalentExample piping lengthExample

Max. 50 m

Max. 40 m

Max. 15 m

Max. 15 m

ao

l

n

be

Max.5 mP

mh i

k

BP unit

BP unit

RA RA

RA

RA

Single use only

*Colours in the diagram following are merely for identifying pipes referenced with symbols such as a .

RA: Residential indoor unit

Between BP unit and

indoor unit

First outdoor branch

*The rest of indoor units are the same as for single use.

First indoor branch First indoor branch

*Colours in the diagram above are merely for identifying pipes referenced with symbols such as a .

Max. 120 m

Actual piping length

Max. 140 m

Equivalent piping length

Max. 300 m

Total piping length

Max. 100 m

Actual piping length

Max. 120 m

Equivalent piping length

Max. 200 m

Total piping length

a

i

s

r

hgf

edcb

Single use

113 114

VR

V IV

W S

erie

s

VRV IV W Series

The reluctance DC motor uses 2 different types of torque, neodymium magnet and reluctance torque. It generates more power with a smaller electric power and saves energy.

Advanced Technologies

High efficiency compressor to achieve a high performance

Surplus oil is stored in the receiver and automatically controls the amount of refrigeration oil in the refrigerant cycle.This prevents a reduction in performance for heat exchanger.

Minimize performance degradation from refrigeration oil in all stages of operation

Auto-restart technology

Refrigerant pressure detection technology

• Utilizes temperature sensors to detect the system’s operating status.

• Employs high and low pressure sensors to carry out quick, comprehensive and accurate detection of the refrigerant status.

Outside unit combinations

Lineup

Outside Unit LineupVRV IV W Series

HP Model Combination

6

8

10

12

14

16

18

20

22

24

26

28

30

32

34

36

16.0

22.4

28.0

33.5

38.4

44.8

50.4

56.0

61.5

67.0

72.8

78.4

84.0

89.5

95.0

101

RWEYQ6T

RWEYQ8T

RWEYQ10T

RWEYQ12T

RWEYQ14T*1

RWEYQ16T*1

RWEYQ18T*1

RWEYQ20T*1

RWEYQ22T*1

RWEYQ24T*1

RWEYQ26T*1

RWEYQ28T*1

RWEYQ30T*1

RWEYQ32T*1

RWEYQ34T*1

RWEYQ36T*1

RWEYQ6T × 1

RWEYQ8T × 1

RWEYQ10T × 1

RWEYQ12T × 1

RWEYQ6T + RWEYQ8T

RWEYQ8T × 2

RWEYQ8T + RWEYQ10T

RWEYQ10T × 2

RWEYQ10T + RWEYQ12T

RWEYQ12T × 2

RWEYQ8T × 2 + RWEYQ10T

RWEYQ8T + RWEYQ10T × 2

RWEYQ10T × 3

RWEYQ10T × 2 + RWEYQ12T

RWEYQ10T + RWEYQ12T × 2

RWEYQ12T × 3

75 to 195

100 to 260

125 to 325

150 to 390

175 to 455

200 to 520

225 to 585

250 to 650

275 to 715

300 to 780

325 to 845

350 to 910

375 to 975

400 to 1,040

425 to 1,105

450 to 1,170

9

13

16

19

22

26

29

32

35

39

42

45

48

52

55

58

kW

150

200

250

300

350

400

450

500

550

600

650

700

750

800

850

900

Capacity index

Total capacity index of connectable indoor units*2

Maximum number ofconnectable indoor units

RWEYQ6TRWEYQ8TRWEYQ10TRWEYQ12T

16.022.4

28.033.5

68

1012

150200

250300

120160

200240

80%*2

Combination (%)*2

Total capacity index of connectable indoor units*2

913

1619

Model name*1 kW HPCapacity

indexMaximum number of

connectable indoor units

150200

250300

100%

195130%

260

325390

For connection of only VRV indoor units

For connection of only residential indoor units

*1. An outside unit multi connection piping kit (option) is necessary for multiple connections of 14 HP systems and above.*2. Total capacity index of connectable indoor units must be 50%–130% of the capacity index of the outside units.

*1. Only single outside unit (RWEYQ6-12T) can be connected.*2. Total capacity index of connectable indoor units must be 80%–130% of the capacity index of the outside unit.

6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36

16.0 22.4 28.0 33.5 38.4 44.8 50.4 56.0 61.5 67.0 72.8 78.4 84.0 89.5 95.0 101

HP

kW

CapacityRange

VRV IV W SERIES

Reluctance DC motor

New oil receiver

Oil separator

Compressor

Power interruption during normal operation

Keep a record of the operating mode adopted

Restore itself back into the recorded operating status

power supplyrecovers

SMT* packaging technology

• Improves the anti-clutter performance.• Protects your computer boards from the

adverse effects of sandy climates and humid weather.

*SMT: Surface mounted technology

SMT packaging material

Computer control board

Computer control board surface adopting SMT packaging technology

Function of information display by luminous digital tube

VRV IV W series utilises a bright 7-segment digital display to convey operational status and facilitate simple installation and after-sales service.

7-segment digital display

Displays system operation information directly

Automatic sequencing operation

Stage 3

Priority

Automaticsequencing

132

Stage 2

Priority

Automaticsequencing

213

Stage 1

Priority 321

115 116

VR

V IV

W S

erie

s

VRV IV W SeriesFl

oor

Stan

ding

Ceilin

g Su

spen

ded

Cat

egor

yC

eilin

g M

ount

ed C

asse

tte

Cei

ling

Con

ceal

ed D

uct

Indoor Unit Lineup

20

20

2.0

25 35

25 35

2.5 3.5

50 60 71

50 60 71

5.0 6.0 7.1Rated Capacity (kW)Type Model Name

Capacity Index

Slim CeilingConcealed Duct

Wall Mounted

(700 mm width type)

(900/1,100 mm width type)

Note: BP units are necessary for residential indoor units. Only single outside unit (RWEYQ6-12T) can be connected.

CDXS-EAVMA

FDXS-CVMA

FTXS-FVMA

FTXS-DVMA

FTXS-EVMA

FTXJ-NVMVW

FTXJ-NVMVS

Residential indoor units with connection to BP units

*Refer to page 114 for the maximum number of connectable indoor units.

BP unit BP unit

VRV indoor units only

Residential indoor units only

58Max.

indoor units

19Max.

indoor units

VRV indoor units

FXDSQ-AVM

FXSQ-PAVE

Capacity Range

Capacity Index 20

0.8 HP

20

1.6 HP

40

2.5 HP

63

3.2 HP

80

3 HP

71

4 HP

100

5 HP

125

6 HP

140

8 HP

200

10 HP

250

2 HP1.25 HP

32

62.531.25

1 HP

25

Type Model Name

FXFSQ-AVM

Ceiling Suspended

Wall Mounted

Floor Standing

Concealed Floor Standing

4-Way Flow Ceiling Suspended

Outdoor-Air Processing Unit

FXVQ-NY1

FXVQ-NY16(high static pressure type)

Floor Standing Duct

FXDQ-SPV1

400

16 HP

500

20 HP

FXMQ-MFV1

Heat Reclaim Ventilator

Air Handling Unit

Heat Reclaim Ventilator with DX-Coil and Humidifier

VKM-GA(M)V1

VAM-GJVE

AHUR

Airflow rate 500-1000 m3/h

Airflow rate 150-2000 m3/h

FXEQ-AV36

FXFQ-AVM

FXZQ-AVM

FXCQ-AVM

FXMQ-PAVE

FXMQ-PVM

FXHQ-AVM

FXUQ-AVEB

FXHQ-MAVE

FXAQ-AVM

FXLQ-MAVE

FXNQ-MAVE

FXDQ-PDVE(with drain pump)

FXDQ-PDVET(without drain pump)

FXDQ-NDVE(with drain pump)

FXDQ-NDVET(without drain pump)

6–120 HP

50

40 8071 100 125 140 200 25025 400 50050

(700 mm width type)

( )900/1,100 mmwidth type

New lineup

3D Airflow Duct with Sensing

Middle Static Pressure Duct

Round Flow Cassette with Sensing

Round Flow Cassette

Compact Multi Flow Cassette

Double Flow Cassette

Single Flow Cassette

Slim Duct (Standard)

Middle-High Static Pressure Duct

High Static Pressure Duct

Slim Duct (Compact)

Enhanced range of choices

117 118

VR

V IV

W S

erie

s

VRV IV W Series

Outside Units

Specifications

RWEYQ6TYM––

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

lvory white (5Y7.5/1)1,000 × 780 × 550

Hermetically sealed scroll type

PT1 1/4B intenal threadPT1 1/4B intenal threadPS1/2B intenal thread

10 to 45

R-410A

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

lvory white (5Y7.5/1)(1,000 × 780 × 550) × 2

Hermetically sealed scroll type

15.9 (Flare) 28.6 (Brazing)

22.2*2, 28.6*3 (Brazing) (PT1 1/4B) × 2 intenal thread(PT1 1/4B) × 2 intenal thread(PS1/2B) × 2 intenal thread

5410 to 45

R-410A

54,60016.0

61,40018.02.582.69

1.9

49146 (148)

23-100

3.5

147 (149)

19-100

4.2

19.1 (Brazing) 15.9*2, 19.1*3 (Brazing)

22.2 (Brazing) 19.1*2, 22.2*3 (Brazing)

RWEYQ8TYM––

76,40022.4

85,30025.03.863.98

2.8 9.5 (Flare)

50

RWEYQ10TYM––

95,50028.0

107,00031.55.435.60

3.7

51

RWEYQ12TYM––

114,00033.5

128,00037.57.337.87

4.7 12.7 (Flare)

53

RWEYQ14TYMRWEYQ6TYMRWEYQ8TYM

131,00038.4

147,00043.06.446.67

1.9 + 2.8

146 × 2 (148 × 2)53

23-100

3.5 + 3.5

12.7 (Flare) 19.1 (Flare)

153,00044.8

171,00050.07.727.96

2.8 × 2

172,00050.4

193,00056.59.299.58

2.8 + 3.7

146 + 147 (148 + 149)

20-100

3.5 + 4.2

191,00056.0

215,00063.010.911.2

3.7 × 2

210,00061.5

235,00069.012.813.5

3.7 + 4.7

147 × 2 (149 × 2)55

19-100

4.2 + 4.2

229,00067.0

256,00075.014.715.7

4.7 × 2

56

RWEYQ16TYMRWEYQ8TYMRWEYQ8TYM

RWEYQ18TYMRWEYQ8TYMRWEYQ10TYM

RWEYQ20TYMRWEYQ10TYMRWEYQ10TYM

RWEYQ22TYMRWEYQ10TYMRWEYQ12TYM

RWEYQ24TYMRWEYQ12TYMRWEYQ12TYM

Btu/h

kW

Btu/h

kW

kW

kW

mm

kW

mm

kg

dB(A)

°C

%

kg

Type

Motor output

Liquid

Suction gas *1

High and low pressure gas

Water inlet

Water outlet

Drain outlet

Type

Charge

Cooling

Heating

MODEL

Power supply

Cooling capacity

Heating capacity

Casing colour

Dimensions (H × W × D)

Machine weight (Operating weight)

Sound level

Operation range (Inlet water temp.)

Capacity control

Refrigerant

RWEYQ26TYMRWEYQ8TYMRWEYQ8TYMRWEYQ10TYM

RWEYQ28TYMRWEYQ8TYM

RWEYQ10TYMRWEYQ10TYM

RWEYQ30TYMRWEYQ10TYMRWEYQ10TYMRWEYQ10TYM

287,00084.0

322,00094.516.316.8

3.7 × 3

147 × 3 (149 × 3)

19-100

4.2 + 4.2 + 4.2

Btu/h

kW

Btu/h

kW

kW

kW

mm

kW

mm

kg

dB(A)

°C

%

kg

Type

Motor output

Liquid

Suction gas *1

High and low pressure gas

Water inlet

Water outlet

Drain outlet

Type

Charge

Cooling

Heating

MODEL

Combination units

Power supply

Cooling capacity

Heating capacity

Casing colour

Dimensions (H × W × D)

Machine weight (Operating weight)

Sound level

Operation range (Inlet water temp.)

Capacity control

Refrigerant

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz268,000

78.4300,000

88.014.715.2

lvory white (5Y7.5/1)(1,000 × 780 × 550) × 3

Hermetically sealed scroll type2.8 + 3.7 × 2 19.1 (Flare)

34.9 (Brazing) 28.6*2, 34.9*3 (Brazing) (PT1 1/4B) × 3 intenal thread(PT1 1/4B) × 3 intenal thread(PS1/2B) × 3 intenal thread

146 + 147 × 2 (148 + 149 × 2)

10 to 4520-100R-410A

3.5 + 4.2 + 4.2

56

RWEYQ32TYMRWEYQ10TYMRWEYQ10TYMRWEYQ12TYM

305,00089.5

345,00010118.219.1

3.7 × 2 + 4.7

57

RWEYQ34TYMRWEYQ10TYMRWEYQ12TYMRWEYQ12TYM

RWEYQ36TYMRWEYQ12TYMRWEYQ12TYMRWEYQ12TYM

345,000101

386,000 113 22.0 23.6

4.7 × 3

58

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz324,000

95.0365,000

10720.121.3

lvory white (5Y7.5/1)(1,000 × 780 × 550) × 3

Hermetically sealed scroll type3.7 + 4.7 × 2 19.1 (Flare)

34.9 (Brazing) 28.6*2, 34.9*3 (Brazing)

(PT1 1/4B) × 3 intenal thread(PT1 1/4B) × 3 intenal thread(PS1/2B) × 3 intenal thread

147 × 3 (149 × 3)

10 to 4519-100R-410A

4.2 + 4.2 + 4.2

248,00072.8

278,00081.513.213.6

2.8 × 2 + 3.7

146 × 2 + 147 (148 × 2 + 149)55

21-100

3.5 + 3.5 + 4.2

Notes:1. Specifications are based on the following

conditions:• Cooling: Indoor temp.: 27ºCDB, 19ºCWB / inlet

water temp.:30ºC, Equivalent piping length: 7.5 m, Level difference: 0 m.

• Heating: Indoor temp.: 20ºCDB / inlet water temp.: 20ºC, Equivalent piping length: 7.5 m, Level difference: 0 m.

• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode.When there is concern for noise to the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

2. This unit cannot be installed in the outdoors. Install indoors (Machine room, etc).

3. Hold ambient temperature at 0 – 40ºC and humidity at 80%RH or less. Heat rejection from the casing: 0.51 kW / 6 - 8 HP / hour, 0.58 kW / 10 - 12 HP / hour.

4. Connectable to closed type cooling tower only.*1: In the case of heat pump system, suction gas

pipe is not used.*2: In the case of heat recovery system.*3: In the case of heat pump system.

• Be sure to refer to the Engineering Data Book for facility design.

Compressor

Refrigerant piping connections

Water piping connections

Compressor

Refrigerant piping connections

Water piping connections

Combination units

Power consumption

Power consumption

VRV IV W Series

Heat Pump

119 120

VR

V IV

Hea

t R

eco

very

Ho

t W

ater

Sys

tem

VRV IV Heat Recovery Hot Water System

Flexible combination of VRV IV indoor units achieves comfort and aesthetic

Air conditioning combined with hot water supply – Compact system

Extremely energy-efficient energy source

Outdoor unit

Air conditioning indoor unit

Hot water storage tank

Serpentine heat exchanger unit

The system can be used in combination with other water heaters depending on the required amount and temperature of hot water.

Energy to supply hot water – Cost-effective

Hot water temperature – Up to 65 °C

Can be used in combination with other water heaters depending on the required amount and temperature of hot water.

AIR CONDITIONING

HOT WATER SUPPLY

Comfortable Air Conditioning and Energy-efficient Hot Water Heating

6HP–60HP

Cooling Only

(16 kW) (168 kW)

Double outdoor units

RWHQ12-16THYM

Triple outdoor units

RWHQ18-50THYM

High-COP Type

Single outdoor units

RWHQ6-16TYM

Double outdoor units

RWHQ18-32TNYM

Triple outdoor units

RWHQ34-60TNYM

Standard Type

Single outdoor units

RWHQ18-20TYM

Double outdoor units

RWHQ22-40TSYM

Triple outdoor units

RWHQ42-50TSYM

Space Saving Type

121 122

VR

V IV

Hea

t R

eco

very

Ho

t W

ater

Sys

tem

VRV IV Heat Recovery Hot Water System

BRCS82

The serpentine heat exchanger unit recovers heat

In a conventional system, waste heat from air conditioning is released into the ambience.

This system recovers waste heat from airconditioning to heat water.

Innovative and Reliable System

Waste heat from air conditioning (which usually released into the ambience) is recovered to heat water

Example on usage of VRV IV Heat Recovery Hot Water System for residence

The energy-ef f icient system recovers waste heat as energy to heat water

Hot air discharge

Ambient air

CirculatingPump

Compact, lightweight design

Refrigerant pipe(Outlet)Water pipe

(Inlet)

Water in

Refrigerant out

Refrigerant in

Water out

Refrigerant pipe(Inlet)

Water pipe(Outlet)

The waste heat from air conditioning is transferred to heat water. This mechanism reduces the amount of heat processed by the outdoor unit, resulting in better operation efficiency. The EER for VRV IV Heat Recovery Hot Water has increased from 4.41 to 4.50, compared with the conventional VRV IV.

Increased energy efficiency of the outdoor unit

The temperature of exhaust heat from the outdoor unit is lower, minimising in ambient temperature increase. In the event of a short circuit, capacity reduction is minimised.

Reducing short circuits

Air conditioner load conditions / Operation time: 16 hours/dayWater-heating load Tank capacity: 200 L Boiling temperature: 25˚C to 60˚C (tap water) Amount of hot water per person per time (standard): 50 L/shower (39˚C) (water dispensed: 10 L/min.; shower time: 5 min./shower) Amount of water required in tank to dispense 39˚C hot water

Comparison between VRV IV Heat Recovery Hot Water System and electric heater

No electric heater consumption(Water heating by the use of waste heat)

Electric heater VRV IV Heat Recovery Hot Water System + water pump

94%reduction

1000

An

nu

al p

ow

er c

on

sum

pti

on

[kW

h]

2000

3000

4000

0

Family composition

3 adults50 L 50 L

X

= 12 showers (600 L (39˚C))3 children

2 showers / person / day

5 6 7 8 9 10 11 12 13 14 15 16 17

Time

VRV Heat load

70%

50%

30%

OFF

150L

60˚C

25˚C

0L

Hot water supply pattern

Water Temp.

18 19 20 21 22 23 24 1 2 3

40˚C

ON ONOFF

4

Because waste heat is used to heat water, annual electricity consumption can be reduced approximately 94% compared with consumption for separate operation of air conditioning and an electric water heater.

In a sample family model of 3 adults and 3 children, the waste heat generated by air conditioning is sufficient to supply hot water for everybody’s showers.

VRV IV Heat Recovery Hot Water controllerConvertible Remote Controller Main Remote Control & Sub Remote Controller are both convertible and interchangeable.

Anti-BacteriaBy default, this would be activated every Monday morning at 2am, heating storage water up to 60°C for 10 minutes.

Vacation ModeThis disables all other functions, except for anti-bacterial mode.

Auto RestartWhen power supply is restored after a failure, the system would revert to the last operational function.

Safety-Error CodeIf thermistors or communication line are faulty, as a safety precaution, operation of the electric heater is disabled.

234 kWh

Ambient air

Lower hot air discharge

The proprietary Serpentine Heat Exchanger achieves excellent heat exchange efficiency.

The high-temperature, high-pressure refrigerant pipe is coiled around the water pipe.

Refrigerant leakage does not contaminate water.

HotWater

StorageTank

Generally, all air conditioners are not in operation during the day because parents are working.

Generally, all air conditioners are not in operation during the day because parents are working.

3,986 kWh

When cooling, if the temperature drops in the storage water heater, the unit starts water heating operations by using the waste heat.When cooling, if the temperature drops in the storage water heater, the unit starts water heating operations by using the waste heat.

123 124

VR

V IV

Hea

t R

eco

very

Ho

t W

ater

Sys

tem

VRV IV Heat Recovery Hot Water SystemC

eilin

g M

ount

ed C

asse

tte

Cat

egor

yC

eilin

g C

once

aled

Duc

tCe

iling

Susp

ende

dFl

oor

Stan

ding

Note: BP units (BPMKS967A2/3) are necessary for residential indoor units.

A mixed of stylish and quiet VRV type indoor units and residential type indoor units can be combined into one system.

Indoor Unit Lineup

Enhanced range of choices

FXFSQ-AVMRound Flow Cassette with Sensing

Air Handling Unit AHUR

Heat Reclaim Ventilator

Heat Reclaim Ventilator with DX-Coil and Humidifier

VKM-GA(M)V1

VAM-GJVE

Airflow rate 500-1000 m3/h

Airflow rate 150-2000 m3/h

Clean Room Air ConditionerFXBQ-PVE

FXBPQ-PVE

FXVQ-NY1

FXVQ-NY16(high static pressure type)

Floor Standing Duct

Wall Mounted

Floor Standing

Concealed Floor Standing

FXAQ-AVM

FXLQ-MAVE

FXNQ-MAVE

Ceiling SuspendedFXHQ-AVM

FXHQ-MAVE

Outdoor-Air Processing Unit FXMQ-MFV1

FXMQ-PAVE

FXMQ-PVM

FXSQ-PAVEMiddle Static Pressure Duct

Middle-High Static Pressure Duct

High Static Pressure Duct

FXDQ-SPV1Slim Duct (Compact)

Slim Duct (Standard)

FXDQ-PDVE(with drain pump)

FXDQ-PDVET(without drain pump)

FXDQ-NDVE(with drain pump)

FXDQ-NDVET(without drain pump)

FXDSQ-AVM3D Airflow Duct with Sensing

Round Flow Cassette

Compact Multi Flow Cassette

Double Flow Cassette

Single Flow Cassette

4-Way Flow Ceiling Suspended

FXEQ-AV36

FXFQ-AVM

FXZQ-AVM

FXCQ-AVM

FXUQ-AVEB

VRV indoor units

Capacity Range

Capacity Index 20

0.8 HP

20

1.6 HP

40

2.5 HP

63

3.2 HP

80

3 HP

71

4 HP

100

5 HP

125

6 HP

140

8 HP

200

10 HP

250

2 HP1.25 HP

32

62.531.25

1 HP

25

Type Model Name

400

16 HP

500

20 HP

50

40 8071 100 125 140 200 25025 400 50050

FDKS-EAVMB

Slim CeilingConcealed Duct

FTKS-FVM

Wall Mounted

FTKS-BVMA

FDKS-C(A)VMB

FTKJ-NVMVW

FTKS-DVM

FTKJ-NVMVS

Residential indoor units with connection to BP units

Rated Capacity (kW)

Capacity Index

5.0

50

6.0

60

3.52.5

25

Type Model Name

71

7.1

35

50 6025 7135

6–120 HP

(700 mm width type)

(900/1,100 mm width type)

New lineup

(700 mm width type)

(900/1,100 mm width type)

125 126

VR

V IV

Hea

t R

eco

very

Ho

t W

ater

Sys

tem

VRV IV Heat Recovery Hot Water System

Outdoor Units

Specifications

RWHQ8TYM

RWHQ8TYM

RWHQ6TYM

RWHQ8TYM

RWHQ6TYM

RWHQ6TYM

RWHQ16THYM RWHQ18THYM RWHQ20THYM RWHQ22THYM RWHQ24THYMRWHQ12THYM RWHQ14THYM

RWHQ6TYM

RWHQ6TYM

RWHQ6TYM

RWHQ6TYM

RWHQ6TYM

RWHQ8TYM

RWHQ6TYM

RWHQ8TYM

RWHQ8TYM

RWHQ8TYM

RWHQ8TYM

RWHQ8TYM— — —

19.1(Brazing x 3)

19.1(Brazing x 3)

19.1(Brazing x 2)

19.1(Brazing x 2)

7.10 8.68 10.3 10.7 12.2 13.8 15.4

15 to 49

R-410A

185+185

6.4+6.4

60 61

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

RWHQ8TYM

RWHQ8TYM

RWHQ12TYM

RWHQ8TYM

RWHQ10TYM

RWHQ12TYM

RWHQ8TYM

RWHQ12TYM

RWHQ12TYM

RWHQ8TYM

RWHQ12TYM

RWHQ14TYM

RWHQ8TYM

RWHQ14TYM

RWHQ14TYM

RWHQ12TYM

RWHQ12TYM

RWHQ14TYM

RWHQ12TYM

RWHQ14TYM

RWHQ14TYM

RWHQ8TYM

RWHQ8TYM

RWHQ10TYM

RWHQ26THYM RWHQ28THYM RWHQ30THYM RWHQ32THYM RWHQ34THYM RWHQ36THYM RWHQ38THYM RWHQ40THYM

19.1(Brazing x 3)

19.1(Brazing x 3)

15 to 49

R-410A

17.5 19.2 21.3 23.0 24.9 26.7 28.7 30.5

185+185+200 185+200+200 185+200+285 185+285+285 200+200+285 200+285+285

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

MODEL

Combination units

Power supply

Btu/h

kW

kW

kW

m3/min

mm

kg

kg

dB(A)

°CDB

%

Cooling capacity

Power consumption

Capacity control

Casing colour

Type

Type

Charge

Compressor

Airflow rate

Dimensions (HxWxD)

Machine weight

Sound level

Operation range

Refrigerant

Motor output

109,000 131,000 153,000 164,000 186,000 207,000 229,000

32.0 38.4 44.8 48.0 54.4 60.8 67.2

10-100 7-100

Ivory white(5Y7.5/1)

Hermetically Sealed Scroll Type

248,000 267,000 286,000 305,000

Ivory white (5Y7.5/1)

Hermetically Sealed Scroll Type

327,000 348,000 365,000 389,000

72.8 78.3 83.9 89.4 95.9 102 107 114

6-100 5-100 4-100

119+119

34.9(Brazing) 41.3(Brazing)

12.7(Brazing) 15.9(Brazing)

28.6(Brazing) 34.9(Brazing)

119+157 157+157 119+119+119 119+119+157 119+157+157 157+157+157

(2.4x1)+(2.4x1)

(2.4x1)+(3.4x1)

(3.4x1)+(3.4x1)

(2.4x1)+(2.4x1)+(2.4x1)

(2.4x1)+(2.4x1)+(3.4x1)

(2.4x1)+(3.4x1)+(3.4x1)

(3.4x1)+(3.4x1)+(3.4x1)

(1,657x930x765)+(1,657x930x765) (1,657x930x765)+(1,657x930x765)+(1,657x930x765)

157+157+165

(3.4x1)+(3.4x1)+(4.1x1)

(1,657x930x765)+(1,657x930x765)+(1,657x930x765)

157+157+178

(3.4x1)+(3.4x1)+(5.2x1)

157+165+178

(3.4x1)+(4.1x1)+(5.2x1)

157+178+178

(3.4x1)+(5.2x1)+(5.2x1)

157+178+233 178+178+233 178+233+233157+233+233

(3.4x1)+(5.2x1)+(2.9x1)+(3.3x1)

(5.2x1)+(5.2x1)+(2.9x1)+(3.3x1)

(3.4x1)+(2.9x1)+(3.3x1)+(2.9x1)+(3.3x1)

(5.2x1)+(2.9x1)+(3.3x1)+(2.9x1)+(3.3x1)

(1,657x930x765)+(1,657x930x765)+(1,657x1,240x765)

(1,657x930x765)+(1,657x1,240x765)+(1,657x1,240x765)

(1,657x930x765)+(1,657x930x765)+(1,657x1,240x765)

(1,657x930x765)+(1,657x1,240x765)+(1,657x1,240x765)

High-COP Type

Standard Type

RWHQ6TYM RWHQ8TYM RWHQ10TYM RWHQ12TYM RWHQ14TYM RWHQ16TYM

54,600

16.0

3.55

76,400

22.4

5.13

95,500

28.0

7.22

16-100

114,000

33.5

8.93

15-100

136,000

40.0

10.8

11-100

154,000

45.0

12.9

10-100

57

6.5

59

6.8

60

10.3

61

10.4

2.4x1 3.4x1 4.1x1 5.2x1

119 157 165 178 233

(2.9x1)+(3.3x1) (3.6x1)+(3.7x1)

1,657x930x765 1,657x1,240x765

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

Hermetically Sealed Scroll Type

12.7(Brazing) 19.1(Brazing) 22.2(Brazing)

15 to 49

R-410A

— — — — — —

Ivory white (5Y7.5/1)

MODEL

Power supply

Power consumption

Capacity control

Compressor

Dimensions (H×W×D)

Machine weight

Sound level

Refrigerant

Btu/h

kW

kW

%

kg

dB(A)

ºCDB

kg

kW

m3/min

mm

Charge

Type

Type

Liquid

Gas

mm

mm

mm

mm

Combination units

Cooling capacity

Motor output

Airflow rate

Operation range

Casing colour

19.1(Brazing)

19.1(Brazing)

Inlet pipe

Outlet pipe

Pipingconnections(Heat exchanger unit)

Pipingconnections(Indoor unit)

409,000

120

32.4

427,000

125

34.5

444,000

130

36.6

461,000

135

38.7

478,000

140

41.1

RWHQ14TYM

RWHQ14TYM

RWHQ14TYM

RWHQ14TYM

RWHQ14TYM

RWHQ16TYM

RWHQ14TYM

RWHQ16TYM

RWHQ16TYM

RWHQ16TYM

RWHQ16TYM

RWHQ16TYM

RWHQ16TYM

RWHQ16TYM

RWHQ18TYM

RWHQ42THYM RWHQ44THYM RWHQ46THYM RWHQ48THYM RWHQ50THYM

(1,657x1,240x765)+(1,657x1,240x765)+(1,657x1,240x765)

233+233+233

10.4+10.4+10.4

(2.9x1)+(3.3x1)+(2.9x1)+(3.3x1)+(2.9x1)+(3.3x1)

(2.9x1)+(3.3x1)+(2.9x1)+(3.3x1)+(3.6x1)+(3.7x1)

(2.9x1)+(3.3x1)+(3.6x1)+(3.7x1)+(3.6x1)+(3.7x1)

(3.6x1)+(3.7x1)+(3.6x1)+(3.7x1)+(3.6x1)+(3.7x1)

(3.6x1)+(3.7x1)+(3.6x1)+(3.7x1)+(4.4x1)+(4.0x1)

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

Hermetically Sealed Scroll Type

15 to 49

R-410A

Ivory white (5Y7.5/1)

MODEL

Power supply

Power consumption

Capacity control

Compressor

Dimensions (H×W×D)

Machine weight

Sound level

Refrigerant

Btu/h

kW

kW

%

kg

dB(A)

ºCDB

kg

kW

m3/min

mm

Type

Combination units

Cooling capacity

Motor output

Airflow rate

Operation range

Casing colour

19.1(Brazing x 3) 19.1(Brazing x 3)

5958

185+185+185

6.4+6.4+6.4

28.6(Brazing)

61

6.4+6.4+6.5 6.4+6.4+6.8

62

6.4+6.5+6.8 6.4+6.8+6.8

63

6.4+6.8+10.3 6.4+10.3+10.3

64

6.8+6.8+10.3 6.8+10.3+10.3

19.1(Brazing)

3-1004-100

10.3+10.3+10.3 10.3+10.3+10.4

65

285+285+285

10.3+10.4+10.4

66

10.4+10.4+10.5

19.1(Brazing) 41.3(Brazing)

20-100

55

185

6.4

56

9.5(Brazing)

Pipingconnections(Heat exchanger unit)

Pipingconnections(Indoor unit)

Charge

Liquid

Gas

mm

mm

mm

mm

Inlet pipe

Outlet pipe

Type

Pipingconnections(Heat exchanger unit)

Pipingconnections(Indoor unit)

Liquid

Gas

mm

mm

mm

mm

Inlet pipe

Outlet pipe

285200

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. When there is concern for noise to the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

VRV IV Heat Recovery Hot Water System

127 128

VR

V IV

Hea

t R

eco

very

Ho

t W

ater

Sys

tem

VRV IV Heat Recovery Hot Water System

Outdoor Units

Specifications

RWHQ8TYM

RWHQ14TYM

RWHQ8TYM

RWHQ12TYM

RWHQ8TYM

RWHQ10TYM

RWHQ22TNYM RWHQ24TNYM RWHQ26TNYM RWHQ28TNYM RWHQ30TNYMRWHQ18TNYM RWHQ20TNYM

RWHQ10TYM

RWHQ14TYM

RWHQ12TYM

RWHQ14TYM

RWHQ14TYM

RWHQ14TYM

RWHQ14TYM

RWHQ16TYM

— — — — — — — —

19.1(Brazing x 2)

19.1(Brazing x 2)

12.4 14.1 15.9 18.0 19.7 21.6 23.7

15 to 49

R-410A

185+200 185+285 200+285 285+285

63 64

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

RWHQ10TYM

RWHQ12TYM

RWHQ12TYM

RWHQ12TYM

RWHQ12TYM

RWHQ12TYM

RWHQ8TYM

RWHQ12TYM

RWHQ18TYM

RWHQ12TYM

RWHQ12TYM

RWHQ16TYM

RWHQ12TYM

RWHQ14TYM

RWHQ16TYM

RWHQ12TYM

RWHQ16TYM

RWHQ16TYM

RWHQ14TYM

RWHQ14TYM

RWHQ18TYM

RWHQ14TYM

RWHQ18TYM

RWHQ32TNYM RWHQ34TNYM RWHQ36TNYM RWHQ38TNYM RWHQ40TNYM RWHQ42TNYM RWHQ44TNYM RWHQ46TNYM

19.1(Brazing x 3)

19.1(Brazing x 3)

15 to 49

R-410A

26.1 25.1 26.8 29.4 30.8 32.6 34.7 36.9

285+285 200+200+200 185+200+285 200+200+285 200+285+285 285+285+285

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

MODEL

Combination units

Power supply

Btu/h

kW

kW

kW

m3/min

mm

kg

kg

dB(A)

°CDB

%

Cooling capacity

Power consumption

Capacity control

Casing colour

Type

Type

Charge

Compressor

Airflow rate

Dimensions (HxWxD)

Machine weight

Sound level

Operation range

Refrigerant

Motor output

172,000 191,000 213,000 232,000 251,000 273,000 290,000

50.4 55.9 62.4 68.0 73.5 80.0 85.0

8-100 7-100 6-100 5-100

Ivory white (5Y7.5/1)

Hermetically Sealed Scroll Type

307,000 324,000 345,000 362,000

Ivory white (5Y7.5/1)

Hermetically Sealed Scroll Type

382,000 406,000 423,000 444,000

90.0 95.0 101 106 112 119 124 130

5-100 4-100 3-100

157+165

34.9(Brazing) 41.3(Brazing)

19.1(Brazing)15.9(Brazing)

28.6(Brazing) 34.9(Brazing)

157+178 157+233 165+233 178+233 233+233

(3.4x1)+(4.1x1)

(3.4x1)+(5.2x1)

(3.4x1)+(2.9x1)+(3.3x1)

(4.1x1)+(2.9x1)+(3.3x1)

(5.2x1)+(2.9x1)+(3.3x1)

(2.9x1)+(3.3x1)+(2.9x1)+(3.3x1)

(2.9x1)+(3.3x1)+(3.6x1)+(3.7x1)

(1,657x930x765)+(1,657x930x765)

(1,657x1,240x765)+(1,657x1,240x765)

(1,657x1,240x765)+(1,657x1,240x765)(1,657x930x765)+(1,657x1,240x765)

233+233

(2.9x1)+(3.3x1)+(4.4x1)+(4.0x1)

(1,657x930x765)+(1,657x930x765)+(1,657x930x765)

(1,657x930x765)+(1,657x930x765)+(1,657x1,240x765)

(1,657x930x765)+(1,657x1,240x765)+(1,657x1,240x765)

165+178+178

(4.1x1)+(5.2x1)+(5.2x1)

178+178+178

(5.2x1)+(5.2x1)+(5.2x1)

157+178+233

(3.4x1)+(5.2x1)+(4.4x1)+(4.0x1)

178+178+233 233+233+233178+233+233

(5.2x1)+(5.2x1)+(3.6x1)+(3.7x1)

(5.2x1)+(3.6x1)+(3.7x1)+(3.6x1)+(3.7x1)

(5.2x1)+(2.9x1)+(3.3x1)+(3.6x1)+(3.7x1)

(2.9x1)+(3.3x1)+(2.9x1)+(3.3x1)+(4.4x1)+(4.0x1)

(1,657x1,240x765)+(1,657x1,240x765)+(1,657x1,240x765)

Standard Type

Space Saving TypeStandard Type

RWHQ18TYM RWHQ20TYM RWHQ22TSYM RWHQ24TSYM

171,000

50.0

15.3

10-100

191,000

56.0

17.9

210,000

61.5

16.2

8-100

229,000

67.0

17.9

(4.4x1)+(4.0x1) (4.6x1)+(5.5x1) (4.1x1)+(5.2x1) (5.2x1)+(5.2x1)

233 268 165+178 178+178

1,657x1,240x765 (1,657x930x765)+(1,657x930x765)

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

Hermetically Sealed Scroll Type

28.6(Brazing) 34.9(Brazing)

15 to 49

R-410A

— —

Ivory white (5Y7.5/1)

RWHQ10TYM RWHQ12TYM

RWHQ12TYM RWHQ12TYM

— —

MODEL

Power supply

Power consumption

Capacity control

Compressor

Dimensions (H×W×D)

Machine weight

Sound level

Refrigerant

Btu/h

kW

kW

%

kg

dB(A)

ºCDB

kg

kW

m3/min

mm

Charge

Type

Type

Liquid

Gas

mm

mm

mm

mm

Combination units

Cooling capacity

Motor output

Airflow rate

Operation range

Casing colour

19.1(Brazing)

19.1(Brazing)

Inlet pipe

Outlet pipe

Pipingconnections(Heat exchanger unit)

Pipingconnections(Indoor unit)

461,000

135

39.0

478,000

140

41.4

495,000

145

43.5

512,000

150

45.9

532,000

156

48.5

RWHQ14TYM

RWHQ16TYM

RWHQ18TYM

RWHQ14TYM

RWHQ18TYM

RWHQ18TYM

RWHQ16TYM

RWHQ18TYM

RWHQ18TYM

RWHQ18TYM

RWHQ18TYM

RWHQ18TYM

RWHQ18TYM

RWHQ18TYM

RWHQ20TYM

RWHQ48TNYM RWHQ50TNYM RWHQ52TNYM RWHQ54TNYM RWHQ56TNYM

(1,657x1,240x765)+(1,657X1,240x765)+(1,657x1,240x765)

10.5+10.5+10.5

(2.9x1)+(3.3x1)+(3.6x1)+(3.7x1)+(4.4x1)+(4.0x1)

(2.9x1)+(3.3x1)+(4.4x1)+(4.0x1)+(4.4x1)+(4.0x1)

(3.6x1)+(3.7x1)+(4.4x1)+(4.0x1)+(4.4x1)+(4.0x1)

(4.4x1)+(4.0x1)+(4.4x1)+(4.0x1)+(4.4x1)+(4.0x1)

(4.4x1)+(4.0x1)+(4.4x1)+(4.0x1)+(4.6x1)+(5.5x1)

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

Hermetically Sealed Scroll Type

15 to 49

R-410A

Ivory white (5Y7.5/1)

MODEL

Power supply

Power consumption

Capacity control

Compressor

Dimensions (H×W×D)

Machine weight

Sound level

Refrigerant

Btu/h

kW

kW

%

kg

dB(A)

ºCDB

kg

553,000

162

51.1

573,000

168

53.7

(4.4x1)+(4.0x1)+(4.6x1)+(5.5x1)+(4.6x1)+(5.5x1)

(4.6x1)+(5.5x1)+(4.6x1)+(5.5x1)+(4.6x1)+(5.5x1)

RWHQ18TYM

RWHQ20TYM

RWHQ20TYM

RWHQ58TNYM

RWHQ20TYM

RWHQ20TYM

RWHQ20TYM

RWHQ60TNYM

kW

m3/min

mm

Type

Combination units

Cooling capacity

Motor output

Airflow rate

Operation range

Casing colour

19.1(Brazing x 3) 19.1(Brazing x 3)

61 6260

10.3+10.410.3+10.36.8+10.36.5+10.36.4+10.36.4+6.5 6.4+6.8

64 63

10.3+10.5 6.5+6.8+6.8

64

6.8+6.8+6.8 6.4+6.8+10.5 6.8+6.8+10.4 6.8+10.3+10.4

65 66

6.8+10.4+10.4 10.3+10.3+10.5

19.1(Brazing)

3-100

10.3+10.4+10.5 10.3+10.5+10.5

66

320+320+320285+320+320285+285+320285+285+285

268+268+268233+268+268233+233+268233+233+233

10.4+10.5+10.5

67 68 69 70

10.5+10.5+11.8 10.5+11.8+11.8 11.8+11.8+11.8

19.1(Brazing) 41.3(Brazing)

62

285 320

10.5 11.8 6.8+6.86.5+6.8

65 61 62

15.9(Brazing)

Pipingconnections(Heat exchanger unit)

Pipingconnections(Indoor unit)

Charge

Liquid

Gas

mm

mm

mm

mm

Inlet pipe

Outlet pipe

Type

Pipingconnections(Heat exchanger unit)

Pipingconnections(Indoor unit)

Liquid

Gas

mm

mm

mm

mm

Inlet pipe

Outlet pipe

200+200

19.1(Brazing x 2)

19.1(Brazing x 2)

19.1(Brazing x 2)

19.1(Brazing x 2)

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. When there is concern for noise to the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

VRV IV Heat Recovery Hot Water System

129 130

VR

V IV

Hea

t R

eco

very

Ho

t W

ater

Sys

tem

VRV IV Heat Recovery Hot Water System

Outdoor Units

Specifications

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

During actual operation, these values are normally somewhat higher as a result of ambient conditions and oil recovery mode. When there is concern for noise to the surrounding area such as residences, we recommend investigating the installation location and taking soundproofing measures.

RWHQ12TYM

RWHQ18TYM

RWHQ12TYM

RWHQ16TYM

RWHQ8TYM

RWHQ18TYM

RWHQ30TSYM RWHQ32TSYM RWHQ34TSYM RWHQ36TSYMRWHQ26TSYM RWHQ28TSYM

RWHQ12TYM

RWHQ20TYM

RWHQ16TYM

RWHQ18TYM

RWHQ18TYM

RWHQ18TYM— — — — — — — —

19.1(Brazing x 2)

19.1(Brazing x 2)

19.1(Brazing x 2)

19.1(Brazing x 2)

20.4 21.8 24.2 26.8 28.2 30.6

15 to 49

R-410A

185+285 200+285 200+320 285+285

65

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

RWHQ20TYM

RWHQ20TYM

RWHQ12TYM

RWHQ12TYM

RWHQ18TYM

RWHQ12TYM

RWHQ12TYM

RWHQ20TYM

RWHQ12TYM

RWHQ16TYM

RWHQ18TYM

RWHQ12TYM

RWHQ18TYM

RWHQ18TYM

RWHQ12TYM

RWHQ18TYM

RWHQ20TYM

RWHQ18TYM

RWHQ20TYM

RWHQ38TSYM RWHQ40TSYM RWHQ42TSYM RWHQ44TSYM RWHQ46TSYM RWHQ48TSYM RWHQ50TSYM

19.1(Brazing x 3)

19.1(Brazing x 3)

15 to 49

R-410A

33.2 35.8 33.2 35.8 37.1 39.5 42.1

285+320 200+200+285320+320 200+200+320 200+285+285 200+285+320

3-phase 4-wire system, 380-415 V/380 V, 50/60 Hz

MODEL

Combination units

Power supply

Btu/h

kW

kW

kW

m3/min

mm

kg

kg

dB(A)

°CDB

%

Cooling capacity

Power consumption

Capacity control

Casing colour

Type

Type

Charge

Compressor

Airflow rate

Dimensions (HxWxD)

Machine weight

Sound level

Operation range

Refrigerant

Motor output

247,000 268,000 285,000 305,000 324,000 341,000

72.4 78.5 83.5 89.5 95.0 100

7-100 6-100 5-100

Ivory white (5Y7.5/1)

Hermetically Sealed Scroll Type

362,000 382,000 399,000 420,000

123

Ivory white (5Y7.5/1)

Hermetically Sealed Scroll Type

440,000 457,000 478,000

106 112 117 129 134 140

4-100 3-100

157+233

41.3(Brazing)

19.1(Brazing)

34.9(Brazing) 41.3(Brazing)

178+233 178+268 233+233

(3.4x1)+(4.4x1)+(4.0x1)

(5.2x1)+(3.6x1)+(3.7x1)

(5.2x1)+(4.4x1)+(4.0x1)

(5.2x1)+(4.6x1)+(5.5x1)

(3.6x1)+(3.7x1)+(4.4x1)+(4.0x1)

(4.4x1)+(4.0x1)+(4.4x1)+(4.0x1)

(1,657x1,240x765)+(1,657x1,240x765)(1,657x1,240x765)+(1,657x1,240x765)(1,657x930x765)+(1,657x1,240x765)

233+268

(4.4x1)+(4.0x1)+(4.6x1)+(5.5x1)

(1,657x930x765)+(1,657x930x765)+(1,657x1,240x765)

(1,657x930x765)+(1,657x1,240x765)+(1,657x1,240x765)

268+268

(4.6x1)+(5.5x1)+(4.6x1)+(5.5x1)

178+178+233

(5.2x1)+(5.2x1)+(4.4x1)+(4.0x1)

178+178+268

(5.2x1)+(5.2x1)+(4.6x1)+(5.5x1)

178+233+233 178+233+268

(5.2x1)+(3.6x1)+(3.7x1)+(4.4x1)+(4.0x1)

(5.2x1)+(4.4x1)+(4.0x1)+(4.6x1)+(5.5x1)

(5.2x1)+(4.4x1)+(4.0x1)+(4.4x1)+(4.0x1)

Space Saving Type

6663 64

10.5+10.510.4+10.56.8+11.86.8+10.56.4+10.5 6.8+10.4

67 68

10.5+11.8 11.8+11.8

65 67

6.8+6.8+10.5 6.8+6.8+11.8 6.8+10.4+10.5 6.8+10.5+10.5

66 67

6.8+10.5+11.8

19.1(Brazing)

Pipingconnections(Heat exchanger unit)

Pipingconnections(Indoor unit)

Liquid

Gas

mm

mm

mm

mm

Inlet pipe

Outlet pipe

VRV IV Heat Recovery Hot Water System

131 132

VR

V IV

Hea

t R

eco

very

Ho

t W

ater

Sys

tem

VRV IV Heat Recovery Hot Water System

Outdoor Units

Serpentine heat exchanger unit (HWHQ30A)

°C

L/min

°C

L/min

kW

kg

mm

mm

mm

mm

m

MPa

m

mm

RWHQ6TYM+HWHQ30A

RWHQ8TYM+HWHQ30A

RWHQ10TYM+HWHQ30A

RWHQ12TYM+HWHQ30A

RWHQ14TYM+HWHQ30A

RWHQ16TYM+HWHQ30A

RWHQ18TYM+HWHQ30A

RWHQ20TYM+HWHQ30A

40

10

20-65

5-20

27

19.1 (Braze)

19.1 (Braze)

25.4 (Screw)

25.4 (Screw)

2 (5)

0.5

0.2

Ivory white (5Y7.5/1)

446 × 306 × 765

Model Name( RWHQ-TYM, HWHQ30A )

Single Heat Exchanger Unit

Rated inlet temperature

Rated water flow

Range of inlet temperature

Range of water flow

Rated Hot-water capacity *1

Machine weight

Diameter of Refrigerant pipe (Gas)

Diameter of Refrigerant pipe (Liquid)

Diameter of water pipe (Inlet)

Diameter of water pipe (Outlet)

Piping length (max)

Design pressure (Water side)

Loss of Head *2

Casing colour

Dimensions (H×W×D)

3.2 3.3 3.3 3.5 3.7 4.0 4.2 4.4

RWHQ6TYM+HWHQ30Ax2

RWHQ8TYM+HWHQ30Ax2

RWHQ10TYM+HWHQ30Ax2

RWHQ12TYM+HWHQ30Ax2

RWHQ14TYM+HWHQ30Ax2

RWHQ16TYM+HWHQ30Ax2

RWHQ18TYM+HWHQ30Ax2

RWHQ20TYM+HWHQ30Ax2

°C

L/min

°C

L/min

kW

kg

mm

mm

mm

mm

m

MPa

m

mm

40

20 (10 × 2)

20-65

10-40 (5-20 × 2)

54 (27 × 2)

19.1 (Braze) × 2

19.1 (Braze) × 2

25.4 (Screw) × 2

25.4 (Screw) × 2

2 (5)

0.5

0.2

Ivory white (5Y7.5/1)

(446 × 306 × 765) + (446 × 306 × 765)

Model Name( RWHQ-TYM, HWHQ30A )

Double Heat Exchanger Unit

Rated inlet temperature

Rated water flow

Range of inlet temperature

Range of water flow

Rated Hot-water capacity *1

Machine weight

Diameter of Refrigerant pipe (Gas)

Diameter of Refrigerant pipe (Liquid)

Diameter of water pipe (Inlet)

Diameter of water pipe (Outlet)

Piping length (max)

Design pressure (Water side)

Loss of Head *2

Casing colour

Dimensions (H×W×D)

5.4 5.6 5.6 5.9 6.2 6.8 7.1 7.4

Pipe length restriction of VRV IV Heat Recovery Hot Water SystemPipe length restriction of VRV IV Heat Recovery Hot Water System

Notes: It is necessary to satisfy the water standard of Daikin for the water that is used. In the case that the water standard is not satisfied, special measures are required. Please contact your local sales office for details. *1: [ Cooling ] Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Inlet water temperature 40°C, Water flow 10L/min, Indoor load 100%, Outdoor-Heat Exchanger Unit 2m.*2: Water flow 10L/min.

Notes: It is necessary to satisfy the water standard of Daikin for the water that is used. In the case that the water standard is not satisfied, special measures are required. Please contact your local sales office for details. *1: [ Cooling ] Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Inlet water temperature 40°C, Water flow 10L/min,Indoor load 100%, Outdoor-Heat Exchanger Unit 2m.*2: Water flow 10L/min.

3 mMax. allowable level difference B Between outdoor unit and heat exchanger unit level

5 mMax. allowable piping length A Between outdoor unit and heat exchanger unit length

3 mMax. allowable level difference B Between outdoor unit and heat exchanger unit level

3 mMax. allowable level difference C Between heat exchanger units

5 mMax. allowable piping length A Between outdoor unit and heat exchanger unit length

Serpentine heat exchanger unit

Serpentine heat exchanger unit

Piping

Outdoor unitOutdoor unit

Piping

Indoor side(as with VRV IV)

B

C

A

A

Serpentine heat exchanger unit

Serpentine heat exchanger unit

Piping

Outdoor unitOutdoor unit

Piping

Indoor side(as with VRV IV)

B

A

A

VRV IV Heat Recovery Hot Water System

133 134

INDOOR UNIT LINEUPDaikin offers a wide range of indoor units including both VRV and residential models responding to variety of needs of our customers that require air-conditioning solutions.

FXAQ-AVM

Wall Mounted Type

Stylish flat panel design harmonised with your interior décor.

163Page

FXVQ-NY1FXVQ-NY16

(high static pressure type)

Floor Standing Duct Type

Large airflow type for large spaces.

167Page

VAM-GJVE

185Page

Cooling OnlyFTKS-DVMFTKS-BVMAFTKS-FVM

Heat PumpFTXS-DVMAFTXS-EVMAFTXS-FVMA

Wall Mounted Type

Stylish flat panel harmonises with your interior décor

173Page Heat Reclaim Ventilator

181Page

Heat Reclaim Ventilator with DX-Coil and Humidifier

FXHQ-AVM

FXHQ-MAVE

Ceiling Suspended Type

Slim body with quiet and wide airflow.

162Page

FXPQ-AVN

Spot Air Conditioner

Personal air comfort delivered to large spaces

168Page

AHUR

Air Handling Unit

Integrate your air handling unit in a total solution for large size spaces such as factories and large stores.

175Page

VKM-GA(M)V1

Cooling OnlyFTKJ-NVMVWHeat PumpFTXJ-NVMVW

Cooling OnlyFTKJ-NVMVSHeat PumpFTXJ-NVMVS

Wall Mounted Type

Elegant appearance with European style

172Page

FXUQ-AVEB

4-Way Flow Ceiling Suspended Type

Slim and stylish design, optimum air distribution, installation without ceiling cavity

161Page

FXNQ-MAVE

Concealed Floor Standing Type

Suitable for perimeter zone air conditioning

166Page

FXLQ-MAVE

Floor Standing Type

Suitable for perimeter zone air conditioning

165Page

FXBQ-PVEFXBPQ-PVE

Clean Room Air Conditioner

Suitable for hospitals and other clean spaces

169Page

Heat PumpCDXS-EAVMAFDXS-CVMA

Cooling OnlyFDKS-EAVMBFDKS-C(A)VMB

Slim Ceiling Concealed Duct Type

Slim and smooth design suitsyour shallow ceiling

171Page

FXZQ-AVM

Compact Multi Flow Cassette Type

Quiet, compact, and designed for user comfort

145Page

FXDSQ-AVM

3D Airflow Duct with Sensing Type

3D airflow with sensing function for comfort and energy savings

151Page

FXSQ-PAVE

Middle Static Pressure Duct Type

Middle static pressure and slim design allow flexible installations.

155Page

FXMQ-MFV1

Outdoor-Air Processing Unit

Combine fresh air treatment and air conditioning, supplied from a single system.

177Page

FXFQ-AVM

Round Flow Cassette Type

360° airflow for improved comfort

141Page

FXEQ-AV36

Single Flow Cassette Type

Slim design for flexible installation

149Page

FXDQ-SPV1

Slim Duct (Compact) Type

Slim and compact design for easy andflexible installation

154Page

FXMQ-PVM

High Static Pressure Duct Type

High static pressure allowsfor flexible duct design.

159Page

FXFSQ-AVM

Round Flow Cassette with Sensing Type

Comfort and energy savings by sensing functions

135Page

FXCQ-AVM

Double Flow Cassette Type

Thin, lightweight, and easy to install in narrow ceiling spaces

147Page

FXDQ-NDVE(T)

FXDQ-PDVE(T)

Slim Duct (Standard) Type

Slim design, quietness and ideal for drop-ceilings

153Page

FXMQ-PAVE

Middle-High Static Pressure Duct Type

Middle and high static pressureallows for flexible duct design.

157Page

Residential indoor units with connection to BP units

Air treatment equipment

VRV indoor units

135 136

Ind

oo

r U

nit

s

VRV Indoor Units

Comfort and energy saving by sensing functions

Sensing sensor stop mode (default: OFF)

Based on preset user conditions, the system automatically stops operation if the room is unoccupied.

*Adjustment is possible for shift time and set temperature by local setting.

Round Flow Cassette with Sensing Type

Auto airflow function

Sensing sensor modeSensors detecting human presence and temperatures near the floor provide comfortable spaces without uneven temperatures.

Comfort and energy saving preventing over cooling/heating

Sensing sensor low mode (default: OFF)

When there are no people in a room, the set temperature is shifted automatically.

Daikin advanced sensing technology

A

CB D

Detecting the average temperature of indoor floor

Detecting the presence of people in 4 areas

Without sensing function With sensing function

Even when room temperature is detected at 30°C, the floor temperature may be as low as 20°C, causing the feet area to be cold.

To prevent an excessive drop in temperature, room temperature is calculated at 27°C when people are in the vicinity.

The sensing function controls airflow to reduce drafts and ensure the feet area is warm.

Uneven temperatures enable minimal drafts, but the feet area becomes cold.

When you try to eliminate uneven temperatures, drafts become strong.

24°C near floor

20°C near floor

20°C near floor

• Cooling setpoint: 26°C

• Shift temperature: 1.0°C

• Shift time: 30 min.

• Limit cooling temperature: 30°C

282726

Occupied UnoccupiedAutomatically reverts when people return.

Setp

oin

t (°

C)

Time

26°C26°C 26°C26°C27°C27°C

28°C28°C

Optimal air direction by “Auto”

When human presence not detected.

Optimal air direction by “Auto”

Swing (narrow)

When human presence detected.Deliver cool air to users

Blown downward

When human presence not detected.

Blown downward Blownhorizontally

When human presence detected.Prevent cold drafts

After30 min

Afteranother 30 min

*When human is not detected for 5 minutes, the unit automatically returns to controlling the flaps for an unoccupied room.

Direct Airflow (default: OFF) Cooling Dry

Draft prevention function (default: OFF)

Heating

Infrared presence sensor

Infrared floor sensor

Example

20°C near floor

30°C near ceiling

17°C near floor

30°C near ceiling

Comfort and energy saving by sensing functions

FXFSQ-A

dual sensors

Energy saving

Comfort

Comfort

toocoldtoocold

feet are coldfeet are cold

CoolingCooling

strong draftstrong draft

HeatingHeating

137 138

Ind

oo

r U

nit

s

VRV Indoor Units

Cooloutdoor

air

Hot outdoor

air

Easy setting is possible with a wired remote controller

Airflow direction can be individually adjusted for each air discharge outlet to deliver optimal air distribution.

Comfort is provided to the entire room by individual setting corresponding to 4-way flow conditions.

Round Flow Cassette with Sensing Type

Configurations of circulation airflowComfortable air conditioning for all room layouts and conditions

Circulation airflow* Individual airflow direction control

During 2-way horizontal flow

Cools by airflow blocking outhot air near windows and walls.

Cool air moves down along thewalls and to every corner of the room.

Comfort without cold air pockets at floor level.

Airflow effectively avoids blowing air directly on people.

30.029.028.027.026.025.024.023.022.021.020.0

30.029.028.027.026.025.024.023.022.021.020.0

Comparison ConditionsRoom size: Width 7.5m x depth 7.5m x height 2.6m

Indoor unit capacity: 71 classOutdoor air temperature: 35°C

Airflow rate and air direction: high / swing

Circulation Airflow (2-way horizontal + 4-way swing)

4-way cassette (Swing)

Performs repeatedlyOperation (at start)

When the target temperature is reached, normal operation (all-round flow) begins.

Circulation airflow cools the entire room to deliver comfort that never feels cold.

Approx. 5%energy savings*

Approx. 15%energy savings*

Cooling

During 2-way horizontal flow

Circulation Airflow (2-way horizontal + 4-way swing)

4-way cassette (Down blow)

Circulation airflow warms the entire room starting from your feet.

Heating

Warms areas around walls using

2-way horizontal flow

Warms the middle of the room using4-way down flow

Warms areas around walls using

2-way horizontal flow

Warms the middle of the room using4-way down flow

Airflow direction changes

Comparison ConditionsRoom size: Width 7.5m x depth 7.5m x height 2.6m

Indoor unit capacity: 71 classOutdoor air temperature: 5°C

Airflow rate and air direction: high / Down blow

30.028.026.024.022.020.018.016.014.012.010.0

30.028.026.024.022.020.018.016.014.012.010.0

* Calculated under the following comparison conditions:When the average temperature at a height of 0.6m

above the floor reaches set temperature. (22°C)

* Calculated under the following comparison conditions:When the average temperature at a height of 0.6m

above the floor reaches set temperature. (26°C)

Cools areas around walls using

2-way horizontal flow

Cools entire room using 4-way swing flow

Cools areas around walls using

2-way horizontal flow

Cools entire room using 4-way swing flow

Performs repeatedlyOperation (at start)

Airflow direction changes

When the target temperature is reached, normal operation (all-round flow) begins.

Warms by airflow blocking outcool air near windows and walls.

Airflow quickly makes the entire room warm and comfortable.

Warmth reliably reaches feet.

Airflow effectively avoids blowing air directly on people.

Individual airflow settings

No individual setting (Auto airflow)Position 0 (Highest point)Position 1Position 2Position 3Position 4 (Lowest point)Swing

Individual settings are possible as stated above.

No individual setting (Auto airflow)

Swing (Up/down)

Position 0(Fixed airflow to highest position)

Position 4(Fixed airflow to the lowest position)

SwingSwing is set for meetings near the windows.

Position 0The airflow is at the highest setting (Position 0) for people who dislike air blowing directly on them.

Blow reduced for areas with few people.

Large blow is provided to meeting areas near windows.

* Applicable when wired remote controller BRC1E63 is used.

No individual setting(Auto airflow)

No individual setting(Auto airflow)

reduce uneven temperatures

reduce uneven temperatures

* Conditions apply for the circulation airflow function. Please contact your local sales office for details.

139 140

Ind

oo

r U

nit

s

VRV Indoor Units

From All-round flow to 2-way flow, various airflow patterns available.

Suitable for high ceilings

Round Flow Cassette with Sensing Type

Comfort Panel (Option)

Installable in tight ceiling spaces

Min. of 261 mm* ceiling space when using standard panel.* For FXFSQ25-80A models.

Drain pump is equipped as standard accessory with 850 mm lift.

Quick and easy installation

Drain pan and drain water check

The condition of the drain pan and drain water can be checked by removing the suction grille and drain plug.

Easy maintenance

Silver ion anti-bacterial drain pan

Filter has anti-mould and antibacterial treatment

Prevents the growth of slime, bacteria, and mould that cause odours and clogging.* Drain pan should be changed once every two to three years.

Cleanliness

Other functions

Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level.

3-way flow L-shaped 2-way flow Opposite 2-way flow

(E.g., installed in a corner) (E.g., installed in a long room)(E.g., installed near a wall)(E.g., installed in middle of ceiling)4-way flow also possible.

All-round flow

Drain outlet(with rubber plug)

Standard panel with sensingBYCQ125EEF (Fresh White)

Standard panel with sensingBYCQ125EEK (Black)

Specifications

0.061

2.8

9,600

3.6

12,300

4.5

15,400

5.6

19,100

kW

Btu/h

Power supply

Cooling capacity

1-phase, 220-240 V/220-230 V, 50/60 Hz

7.1

24,200

11.2

38,200

9.0

30,700

14.0

47,800

16.0

54,600

3.2

10,900

4.0

13,600

5.0

17,100

6.3

21,500

kW

Btu/hHeating capacity

8.0

27,300

12.5

42,700

10.0

34,100

16.0

54,600

FXFSQ25AVM FXFSQ32AVM FXFSQ40AVM FXFSQ50AVMMODEL FXFSQ63AVM FXFSQ100AVMFXFSQ80AVM FXFSQ125AVM FXFSQ140AVM

6.4

12.7 15.9

9.5

0.028 0.035 0.056kWPower consumption

0.194

19

459/441/406/388/353

30/29.5/28.5/28/27

13/12.5/11.5/11/10

600/477/441/424/388

35/29.5/29/28/27

17/13.5/12.5/12/11

812/724/671/512/388

38/35/34.5/29.5/27

23/20.5/19/14.5/11

VP25 (External Dia. 32/Internal Dia. 25)

mm

kg

mm

dB(A)

cfm

m3/min

Drain

Gas (Flare)

Liquid (Flare)

Casing

Sound level (H/HM/M/ML/L)

Airflow rate (H/HM/M/ML/L)

Dimensions (H×W×D)

Machine weight

Piping connections

256×840×840 298×840×840

Galvanised steel plate

830/741/706/565/477

38/36/35.5/31.5/28

23.5/21/20/16/13.5

1,183/1,077/953/830/741

44/41/38/35/33

33.5/30.5/27/23.5/21

865/777/724/706/530

39/37/36/35.5/31

24.5/22/20.5/20/15

1,218/1,112/1,006/900/812

45/42.5/39.5/37/35

34.5/31.5/28.5/25.5/23

1,253/1,147/1,041/935/812

46/43.5/40.5/38/35

35.5/32.5/29.5/26.5/23

0.164 0.1700.092

0.0600.026 0.034 0.056 0.1830.144 0.1590.092

22 2524 26

Panel (Option)

kg

mm

Weight

Dimensions(H×W×D)

Model

50×950×950

5.5

BYCQ125EEF (Fresh White)

Standardpanelwith sensing

kg

mm

Weight

Dimensions(H×W×D)

Model

50×950×950

5.5

BYCQ125EEK (Black)

Cooling

Heating

*1. Applicable when sensing panel is installed.

Wired Wireless

BRC1E63 BRC7M635F(K) / BRC7M634F(K)Remote controller

Function List

High ceiling application

Swing pattern selection

Auto swing

Auto airflow rate

Switchable 5 step fan speed

Individual airflow direction control

Circulation airflow

Sensing sensor stop mode *1

Sensing sensor low mode *1

Direct airflow *1

Dual sensors *1

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Just open the suction grille!

Note: For inquiries concerning auto grille panel installations, please contact your local dealer or Daikin representative.

850 mm

175 mm

141 142

Ind

oo

r U

nit

s

VRV Indoor Units

Comparison ConditionsRoom size: Width 7.5m x depth 7.5m x height 2.6m

Indoor unit capacity: 71 classOutdoor air temperature: 35°C

Airflow rate and air direction: high / swing4-way cassette (Swing)

30.029.028.027.026.025.024.023.022.021.020.0

30.029.028.027.026.025.024.023.022.021.020.0

Circulation Airflow (2-way horizontal + 4-way swing)

4-way cassette (Down blow)

Comparison ConditionsRoom size: Width 7.5m x depth 7.5m x height 2.6m

Indoor unit capacity: 71 classOutdoor air temperature: 5°C

Airflow rate and air direction: high / Down blow

30.028.026.024.022.020.018.016.014.012.010.0

30.028.026.024.022.020.018.016.014.012.010.0

Easy setting is possible with a wired remote controller

Airflow direction can be individually adjusted for each air discharge outlet to deliver optimal air distribution.

Comfort is provided to the entire room by individual setting corresponding to 4-way flow conditions.

Round Flow Cassette Type

Configurations of circulation airflow

Comfortable air conditioning for all room layouts and conditions

Individual airflow direction control

During 2-way horizontal flow

Comfort without cold air pockets at floor level.

When the target temperature is reached, normal operation (all-round flow) begins.

Circulation airflow cools the entire room to deliver comfort that never feels cold.

Approx. 5%energy savings*

Approx. 15%energy savings*

Cooling

During 2-way horizontal flow

Circulation airflow warms the entire room starting from your feet.

Heating

* Calculated under the following comparison conditions:When the average temperature at a height of 0.6m

above the floor reaches set temperature. (26°C)

When the target temperature is reached, normal operation (all-round flow) begins.

Warmth reliably reaches feet.

Individual airflow settings

No individual setting (Auto airflow)Position 0 (Highest point)Position 1Position 2Position 3Position 4 (Lowest point)Swing

Individual settings are possible as stated above.

No individual setting (Auto airflow)

Swing (Up/down)

Position 0(Fixed airflow to highest position)

Position 4(Fixed airflow to the lowest position)

SwingSwing is set for meetings near the windows.

Blow reduced for areas with few people.

Large blow is provided to meeting areas near windows.

* Applicable when wired remote controller BRC1E63 is used.

No individual setting(Auto airflow)

reduce uneven temperatures

reduce uneven temperatures

Performs repeatedlyOperation (at start)

Warms areas around walls using

2-way horizontal flow

Warms the middle of the room using4-way down flow

Warms areas around walls using

2-way horizontal flow

Warms the middle of the room using4-way down flow

Airflow direction changes

* Calculated under the following comparison conditions:When the average temperature at a height of 0.6m

above the floor reaches set temperature. (22°C)

Cools areas around walls using

2-way horizontal flow

Cools entire room using 4-way swing flow

Cools areas around walls using

2-way horizontal flow

Cools entire room using 4-way swing flow

Performs repeatedlyOperation (at start) Airflow

direction changes

Circulation airflow*

360° airflow for improved comfort

FXFQ-A

Circulation Airflow (2-way horizontal + 4-way swing)

Position 0The airflow is at the highest setting (Position 0) for people who dislike air blowing directly on them.

No individual setting(Auto airflow)

Cooloutdoor

air

Hot outdoor

air

Cools by airflow blocking outhot air near windows and walls.

Cool air moves down along thewalls and to every corner of the room.

Airflow effectively avoids blowing air directly on people.

Warms by airflow blocking outcool air near windows and walls.

Airflow quickly makes the entire room warm and comfortable.

Airflow effectively avoids blowing air directly on people.

* Conditions apply for the circulation airflow function. Please contact your local sales office for details.

143 144

Ind

oo

r U

nit

s

VRV Indoor Units

From All-round flow to 2-way flow, various airflow patterns available.

Suitable for high ceilings

Round Flow Cassette Type

Comfort Decoration Panel (Option)

Other functions

Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level.

3-way flow L-shaped 2-way flow Opposite 2-way flow

(E.g., installed in a corner) (E.g., installed in a long room)(E.g., installed near a wall)(E.g., installed in middle of ceiling)4-way flow also possible.

All-round flow

Specifications

Decoration Panel (Option) Function List

Auto grille panel (option)

New designer panel

Grille panel can be lowered to a maximum of 3.9 m.BYCQ125EASF (Fresh White)

Standard panelBYCQ125EAF (Fresh White)

Standard panelBYCQ125EAK (Black)

Designer panelBYCQ125EAPF (Fresh White)

Close to ideal stylingNew designer panel

FLATFlatter styling:

Suction panel grid texture smoothed.

CLEANClean-cut form:

Soiling is hard to seeon smart-looking panel.

ROUNDSubtle distinction:

around suction inletssilvering is a tasteful touch.

kg

mm

Weight

Dimensions(H×W×D)

ModelStandardpanel

5.5

50×950×950

BYCQ125EAF (Fresh White ) / BYCQ125EAK (Black)

kg

mm

Weight

Dimensions(H×W×D)

ModelDesignerpanel

6.5

97×950×950

BYCQ125EAPF (Fresh White)

kg

mm

Weight

Dimensions(H×W×D)

ModelAutogrillepanel

8

105×950×950

BYCQ125EASF (Fresh White)

Wired Wireless

BRC1E63 BRC7M635F(K) / BRC7M634F(K)Remote controller

High ceiling application

Swing pattern selection

Auto swing

Auto airflow rate

Switchable 5 step fan speed

Individual airflow direction control

Circulation airflow

459/441/406/388/353

30/29.5/28.5/28/27

13/12.5/11.5/11/10

600/477/459/424/388

35/29.5/29/28/27

17/13.5/13/12/11

kW

Btu/h

Power supply

Cooling capacity

1-phase, 220-240 V/220-230 V, 50/60 Hz

2.8

9,600

3.6

12,300

4.5

15,400

5.6

19,100 24,200 30,700 38,200 47,800

7.1 9.0 11.2 14.0

54,600

16.0

kW

Btu/hHeating capacity

3.2

10,900

4.0

13,600

5.0

17,100

6.3

21,500 27,300 34,100 42,700 47,800

8.0 10.0 12.5 14.0

54,600

16.0

19 22 25 26

15.9

9.5

12.7

6.4

mm

kg

mm

dB(A)

cfm

m3/min

Drain

Gas (Flare)

Liquid (Flare)

Casing

Sound level (H/HM/M/ML/L)

Airflow rate (H/HM/M/ML/L)

Dimensions (H×W×D)

Machine weight

Piping connections

0.029 0.036 0.040kW

0.158 0.178 0.2030.063 0.096

0.027 0.036 0.040 0.150 0.166 0.1910.063 0.096

18/17/13.5/12.5/11

635/600/477/441/388

35/33.5/29.5/28.5/27

Galvanised steel plate

21/20/16/15/13.5

741/706/565/530/477

36/35.5/31.5/31/28

32/29/26/23/21

1,130/1,024/918/812/741

43/40.5/37.5/35/33

33/30.5/28/25.5/21

1,165/1,077/988/900/741

44/41.5/39/36.5/33

22.5/21.5/21/20/15

794/759/741/706/530

37/36.5/36/35.5/29.5

35.5/32.5/29.5/26.5/23

1,253/1,147/1,041/935/812

46/43.5/40.5/38/35

VP25 (External Dia. 32/Internal Dia. 25)

256×840×840 298×840×840

MODEL FXFQ25AVM FXFQ32AVM FXFQ40AVM FXFQ50AVM FXFQ63AVM FXFQ80AVM FXFQ100AVM FXFQ125AVM FXFQ140AVM

Power consumptionCooling

Heating

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Designer choice has been given a boost with the increase in number of new types of decoration panels.

Grille and air filter cleaning can be performed without need for a stepladder by lowering the grille.

A dedicated remote controller for the auto grille panel (BRC16A2) is included. Operation is not possible using BRC1E63.

Standard panel

Installable in tight ceiling spaces

Min. of 261 mm* ceiling space when using standard panel.* For FXFQ25-80A models.

Drain pump is equipped as standard accessory with 850 mm lift.

Quick and easy installation

Drain pan and drain water check

The condition of the drain pan and drain water can be checked by removing the suction grille and drain plug.

Easy maintenance

Silver ion anti-bacterial drain pan

Filter has anti-mould and antibacterial treatment

Prevents the growth of slime, bacteria, and mould that cause odours and clogging.* Drain pan should be changed once every two to three years.

Cleanliness

Drain outlet(with rubber plug)

Just open the suction grille!

Note: For inquiries concerning auto grille panel installations, please contact your local dealer or Daikin representative.

850 mm

175 mm

145 146

Ind

oo

r U

nit

s

VRV Indoor Units

Compact Multi Flow Cassette Type

Quiet, compact, and designed for user comfort

FXZQ-A

SpecificationsMODEL FXZQ20AVM FXZQ25AVM FXZQ32AVM FXZQ40AVM FXZQ50AVM

Power supply 1-phase, 220-240 V/220 V, 50/60 Hz

Cooling capacityBtu/h 7,500 9,600 12,300 15,400 19,100

kW 2.2 2.8 3.6 4.5 5.6

Heating capacityBtu/h 8,500 10,900 13,600 17,100 21,500

kW 2.5 3.2 4.0 5.0 6.3

Power consumption

Cooling kW 0.043 0.045 0.059 0.092

Heating kW 0.036 0.038 0.053 0.086

Casing Galvanised steel plate

Airflow rate (H/M/L)m³/min 8.7/7.5/6.5 9.0/8.0/6.5 10.0/8.5/7.0 11.5/9.5/8.0 14.5/12.5/10.0

cfm 307/265/229 318/282/229 353/300/247 406/335/282 512/441/353

Sound level (H/M/L) dB(A) 32.0/29.5/25.5 33.0/30.0/25.5 33.5/30.0/26.0 37.0/32.0/28.0 43.0/40.0/33.0

Sound power (H) dB(A) 49 50 51 54 60

Dimensions (H×W×D) mm 260×575×575 (For depth add 63 mm for electrical box)

Machine weight kg 15.5 16.5 18.5

Piping connections

Liquid (Flare)

mm

6.4

Gas (Flare) 12.7

Drain VP20 (External Dia. 26/Internal Dia. 20)

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Compact & elegant design• Fully-flat integration in standard architectural ceiling tiles, leaving

only 8 mm

• Remarkable blend of iconic design and engineering excellence with an elegant finish in white

• The newly designed panel integrates fully within one ceiling tile enabling lights, speakers and sprinklers to be installed in the adjoining ceiling tiles.

Dual sensors (Option)

Efficiency & comfort

Cleanliness

• Two optional intelligent sensors improve energy efficiency and comfort.

• An optional presence and floor sensor kit can be fitted to the cassette for draught prevention, energy-saving operation and to provide optimal control of airflow.

Individual airflow direction control *1

• Airflow direction can be individually adjusted for each air discharge outlet to deliver optimal air distribution.

*1. This function can only be set via wired remote controller BRC1E63.

Auto swing (up/down)Possibility to select automatic vertical moving of the air discharge flaps for efficient air and temperature distribution throughout the room.

Ceiling soiling preventionPrevents air from blowing against the ceiling to prevent ceiling stains.

8 mm

Panel (Option)Panel type Grid ceiling panel Decoration panel

Appearance

Model

Colour

BYFQ60CAW BYFQ60B3W1

Dimensions (H×W×D) mm 46×620×620 55×700×700

White (N9.5) White (6.5Y9.5/0.5)

Weight kg 2.8 2.7

147 148

Ind

oo

r U

nit

s

VRV Indoor Units

No individual setting (Auto airflow)

Position Position 0 (Highest point)Position 1Position 2Position 3Position 4 (Lowest point)

Swing

• Power consumption is significantly reduced by specially developed small tube heat exchanger and DC fan motor.

Energy saving

Stylish design

Comfort

Easy maintenance

Flexible installation

5-step & auto airflow control

• Control of airflow rate has been improved from 3-step to 5-step. Auto airflow rate is newly available.

Individual airflow direction control*1

Suitable for high ceilings

• Even in spaces with high ceilings maximum 3.5 m, a comfortable airflow is carried down to the floor level.

FXCQ-A

Thin, lightweight, and easy to install in narrow ceiling spaces

Specifications

Adjuster Pocket

• The flap parts are easy to clean because it is hard to condensate and get dirty.

• Check contamination in drain pan by simply removing suction grille and panel.

• Adjuster pockets mount at four corners of the unit enable to adjust the main unit without removing the panel.

• Drain pump is equipped as standard accessory with 850 mm lift.

020

95

25/32 40 50 63 80 125

Pow

er c

on

sum

pti

on

(W

)

Model class

200

100

300

132 132157

216

278

31 39 4159 63

90

149

Power consumption comparison (Cooling)

MODEL FXCQ20AVM

Power supply

Cooling capacity

CoolingHeating

Heating capacity

Btu/h

kW

Btu/h

kW

kW

m3/min

cfm

dB(A)

mm

kg

mm

kg

mm

Power consumption

Liquid (Flare)Gas (Flare)

Drain

ModelColour

Dimensions (H×W×D)

Weight

Casing

Airflow rate (H/HM/M/ML/L)

Sound level (H/HM/M/ML/L)

Dimensions (H × W × D)

Machine weight

Piping connections

Panel(Option)

1-phase, 220-240 V/220-230 V, 50/60 Hz7,500

2.2

0.031

Galvanised steel plate

VP25 (External Dia. 32/Internal Dia. 25)

Fresh white (6.5Y 9.5/0.5)

10.5/9.5/9/8/7.5371/335/318/282/26532/31/30/29/28

12/11/10.5/9.5/8.5424/388/371/335/30036/35/33/32/31

15/14/13/11.5/10.5530/494/459/406/37137/36/35/33/31

16/15/14/12.5/11.5565/530/494/441/40639/38/37/35/32

26/24/22.5/20.5/18.5918/847/794/724/65342/40/38/36/33

32/29.5/27.5/25/22.51,130/1,041/971/883/79446/44/42/40/38

11.5/10.5/9.5/8.5/8406/371/335/300/282

34/33/31/30/29 34/33/32/31/30305×775×620

19

BYBCQ40CF

55×1,070×70010

6.412.7

9.515.9

FXCQ25AVM

9,6002.8

0.039

FXCQ32AVM

12,3003.6

FXCQ40AVM

15,4004.5

0.041

FXCQ50AVM

19,1005.6

0.059

22

55×1,285×70011

55×1,740×70013

BYBCQ63CF BYBCQ125CF

305×990×620 305×1,445×620

FXCQ63AVM

24,2007.1

0.063

25

FXCQ80AVM

30,7009.0

0.090

33

FXCQ125AVM

47,80014.0

8,500 10,900 13,600 17,100 21,500 27,300 34,100 54,6002.5 3.2 4.0 5.0 6.3 8.0 10.0 16.0

0.1490.028 0.035 0.037 0.056 0.060 0.086 0.146

38

81

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Conventional model: FXCQ-M New model: FXCQ-A

Silver ion anti-bacterial drain pan

Filter has anti-mould and antibacterial treatment

• Prevents the growth of slime, bacteria, and mould that cause odours and clogging.* Drain pan should be changed once every two to three years.

Cleanliness

Drain socket part

Swing(Up / Down)

Individual settings are possible as stated above.

Individual airflow settings

• Stylish unit blends easily with any interior.

• The flat flaps close entirely when the unit is not operating and there are no air intake grilles visible.

• Depth of all units is 620 mm, ideal for narrow spaces

*1. The function can only be set via BRC1E63.

Position 0(Fixed airflow to highest position)

• Airflow direction can be individually adjusted for each air discharge outlet to deliver optimal air distribution.

Double Flow Cassette Type

149 150

Ind

oo

r U

nit

s

VRV Indoor Units

FXEQ-A

Slim design for flexible installation

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.

• The body features a compact design with a height of just 200 mm and depth 470 mm, making the installation possible in tight ceiling spaces.

• Drain pump is equipped as standard accessory with 850 mm lift.

Specifications

1-phase, 220-240 V, 50 Hz

PVC26 (External Dia. 26/Internal Dia. 20)

19,100 24,2007,500 9,600 12,300 15,400

21,500 27,3008,500 10,900 13,600 17,100

5.6 7.12.2 2.8 3.6 4.5

MODEL

Powerconsumption

Power supply

Heating capacity

Cooling capacity

FXEQ20AV36 FXEQ25AV36 FXEQ32AV36 FXEQ40AV36 FXEQ50AV36 FXEQ63AV36

Airflow rate(H/HM/M/ML/L)

Btu/h

kW

Btu/h

kW 6.3 8.02.5 3.2 4.0 5.0

0.048 0.0670.034 0.046

0.044 0.0630.030 0.042

12.5/11.4/10.4/9.5/8.7 15.0/13.6/12.2/11.0/9.88.0/7.5/7.0/6.3/5.5 9.8/8.8/7.8/7.0/6.2

441/402/367/335/307 530/480/431/388/346282/265/247/222/194 346/311/275/247/219

kW

Dimensions (H×W×D) mm

m3/min

cfm

Cooling

Heating

Piping connections mm

Liquid (Flare)

Gas (Flare)

Drain

Panel (Option)

Model

Colour

Dimensions(H×W×D)

Weight

Galvanised steel plateCasing

Machine weight kg

mm

kg

18 2317

BYEP63AW1BYEP40AW1

Fresh white

80×1,350×55080×950×550

10.08.0

200×1,240×470200×840×470

6.4

12.7

9.5

15.9

0.026 0.027

0.022 0.023

6.0/5.4/4.9/4.4/4.0 6.9/6.4/5.8/5.3/4.8

212/191/173/155/141 244/226/205/187/169

14.0/12.8/11.6/10.7/9.8 16.9/15.3/13.6/12.3/11.08.6/8.0/7.4/6.7/6.0 10.2/9.3/8.4/7.6/6.8

494/452/409/378/346 597/540/480/434/388304/282/261/237/212 360/328/297/268/240

m3/min

cfm

6.0/5.6/5.1/4.7/4.2 7.2/6.7/6.1/5.6/5.0

212/198/180/166/148 254/237/215/198/177

Sound level (H/HM/M/ML/L)

38/37/35/33/31 43/41/39/37/3535/34/33/32/30 38/37/35/33/31

41/39/37/36/34 46/44/42/40/3838/36/34/33/31 41/39/37/35/33dB(A)

Cooling

Heating

Cooling

Heating

30/29/28/27/26 32/31/30/29/28

33/31/29/28/26 35/33/31/30/28

255 mm255 mm

840 mm840 mm470 mm470 mm

Indoor unit 255 mm200 mm

80 mm

• The swinging of horizontal and vertical swing flaps can be adjusted freely with the remote controller, providing 3D airflow to every corner of the room.

• Control of airflow rate can be selected from 5-step control, Automatic and quiet operation mode, which provides comfortable airflow.

• DC motor is adopted both in the fan and drain pump of the indoor unit, not only enhancing the energy saving performance, but also reducing the operating sound and the vibration incurred to the unit.

• While creating a cozy indoor environment, the unit can prevent the suspended ceiling from being soiled by adjusting its louvre angle.

• Maintenance operations can be performed by removing the front panel.

Front view Side view

Vertical swing flaps, swinging to left or right within

Horizontal swing flaps, swinging between

Trave

• The novel smooth panel design makes dust difficult to accumulate, thus causing the cleaning more conveniently.

45° 20° to 70°

Single Flow Cassette Type

Slim design

Comfort

Easy maintenance

151 152

Ind

oo

r U

nit

s

VRV Indoor Units

3D airflow

FXDSQ-A

3D airflow with sensing function for comfort and energy savings

Notes: Specifications are based on the following conditions;•Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 5 m, Level difference: 0 m.•Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 5 m, Level difference: 0 m.•Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)•Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

*1: Values are based on external static pressure of 10 Pa.*2: External static pressure is changeable to set by the remote controller. This pressure means “High static pressure - Standard”. (Factory setting is 10 Pa )*3: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).

Daikin advanced sensing technology

Comfort

Installation flexibility

• Horizontal & Vertical direction can be adjusted freely by the remote controller settings as to provide 3D airflow to every corner of the room.

• Can freely select 5 positions and swing mode for each up/ down and left/right direction with remote controller.

• Slim and compact design with a height of only 200 mm and the depth of only 450 mm which is suitable to install in limited spaces.

1-phase, 220-240/220-230 V, 50/60 Hz19,100 24,2007,500 9,600 12,300 15,400

5.6 7.12.2 2.8 3.6 4.521,500 27,3008,500 10,900 13,600 17,100

6.3 8.02.5 3.2 4.0 5.00.032 0.0540.049

15.0/14.0/13.0/11.5/10.5 19.0/17.0/15.0/13.0/11.59.0/8.5/8.0/7.5/7.0 10.0/9.3/8.6/7.9/7.2

31/29/27/26/24 34/32/30/29/27

12.0/11.2/10.5/9.7/9.0Galvanized steel plate

200×900×450 200×1,100×450200×700×450

12.7 (flare) 6.4 (flare)

15.9 (flare) 9.5 (flare)

0.028 0.0290.028 0.0500.0450.024 0.025

8.7/8.1/7.6/7.0/6.5

39/37/35/33/31 39/37/35/33/3031/29/27/26/24

MODEL

Btu/hkW

kW

m3/min

dB(A)mmkg

mm

kg

mmLiquid (Flare)Gas (Flare)Drain

ColourDimensions (H×W×D)

Weight

Pa

Power supply

Cooling capacity

Btu/hkW

Heating capacity

Power consumption *1

CasingAirflow rate (H/HM/M/ML/L)

Sound level (H/HM/M/ML/L)*1 *3

External static pressure

Dimensions (H×W×D)Machine weight

Piping connections

3D Autoswing panel

Specifications

PVC26 (External Dia. 26 / Internal Dia. 20)

Fresh white

10-0 *2

180×922×70 180×1,122×70180×722×70

1.5 2.01.0

20 2317

CoolingHeating

FXDSQ20AVM FXDSQ25AVM FXDSQ32AVM FXDSQ40AVM FXDSQ50AVM FXDSQ63AVM

Sensing sensor stop mode (default: OFF)

• Based on preset user conditions, the system automatically stops operation if the room is unoccupied.*Adjustment is possible for shift time and set temperature by local setting.

Sensing sensor low mode (default: OFF)

Sensing sensor mode

Comfort and energy saving preventing over cooling / heating

• Cooling setpoint: 26°C• Shift temperature: 1.0°C • Shift time: 30 min.• Limit cooling temperature: 30°C

282726

Occupied UnoccupiedAutomatically reverts when people return.

Setp

oin

t (°

C)

Time

26°C26°C 26°C26°C27°C27°C

28°C28°C

After30 min

Afteranother 30 min

Example

• When there are no people in a room, the set temperature is shifted automatically.

24°C near floor

30°C near ceiling

20°C near floor20°C near floor

Room temperature is calculated as 27°C in the area which is in the vicinity of the person.

The wide coverage of the airflow angle creates a comfortable 3D airflow.

5-step & auto airflow control

Dual sensors

Slim design

* Panel dimensions are not included.

Only 450 mm

200 mm

Infrared presence sensorThe presence sensor detects where people are and adjusts the airflow direction accordingly.

Infrared floor sensorThe sensor detects the floor temperature and automatically adjusts operation of the indoor unit to reduce the temperature difference between the ceiling and the floor.

45° 45°

Horizontal flaps

Vertical flaps

• Control of airflow rate can be selected from 5-step and Auto to provide comfortable airflow.

60° 50°

Cooling range of swing

Heating range of swing

Cooling Heating

Absence Presence

3D Airflow Duct with Sensing Type

153 154

Ind

oo

r U

nit

s

VRV Indoor Units

Comfort

FXDQ-PD / ND

Slim design, quietness and ideal for drop-ceilings

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

During actual operation, these values are normally somewhat higher as a result of ambient conditions. *1: Values are based on the following conditions: FXDQ-PD: external static pressure of 10 Pa; FXDQ-ND: external static pressure of 15 Pa. *2: External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is 10 Pa for FXDQ-PD models and 15 Pa for FXDQ-ND models.) *3: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).

• Control of the airflow rate can be selected from 3-step control and Auto. Auto airflow rate control can be selected with wired remote controller.

• Low operation sound level: down to 23 dB(A)

Installation flexibility• Only 200 mm in height, this model can be

installed in rooms with as little as 240 mm in height for the ceiling space between the drop-ceiling and ceiling slab.

• FXDQ-PD and FXDQ-ND models are available in two types to suit different installation conditions.

Installation flexibility

FXDQ-SP

Slim and compact design for easy and flexible installation

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 5.0 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 5.0 m, Level difference: 0 m.• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.*1: Values are based on the following conditions: FXDQ20-32SP: external static pressure of 10 Pa; FXDQ40-63SP: external static pressure of 20 Pa.*2: External static pressure is changeable to set by the remote controller. This pressure means “High static pressure - Standard”.

(Factory setting is 10 Pa for FXDQ20-32SP models and 20 Pa for FXDQ40-63SP models.)*3: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).

• Slim and compact design with a height of only 200 mm and the depth of only 450 mm which is suitable to install in limited spaces.

SpecificationsMODEL

1-phase, 220-240 V, 50 Hz

Galvanised steel plate

VP20 (External Dia. 26/Internal Dia. 20)

Gas (Flare)

Drain

Liquid (Flare)

FXDQ20SPV1 FXDQ25SPV1 FXDQ32SPV1 FXDQ40SPV1 FXDQ50SPV1 FXDQ63SPV1Power supply

Casing

Cooling capacity

Heating capacity

Airflow rate (HH/H/L)

External static pressure

Machine weight

Dimensions (H×W×D)

Piping connections

Power consumption 1

Sound level (HH/H/L) 1 3

Btu/h

kW

Btu/h

kW

kW

kW

Heating

Cooling

m3/min

dB(A)

Pa

cfm

kg

mm

mm

307/268/229

8.7/7.6/6.5

7,500

2.2

0.056

15,400

4.5

0.152

19,100

5.6

318/282/247

200×700×450

17

9.0/8.0/7.0

30-10

9,600

2.8

0.059

530/459/371

35/33/31

200×900×450

20

15.0/13.0/10.5

50-20353/318/282

34/32/30

10.0/9.0/8.0

12,300

3.6

0.062

6.4

12.7

33/31/29

706/565/441

37/35/33

200×1,100×450

23

20.0/16.0/12.5

24,200

7.1

8,500

2.5

17,100

5.0

21,500

6.3

10,900

3.2

13,600

4.0

27,300

8.0

0.1960.072 0.1800.075 0.078

0.168

9.5

15.9

40-20

Specifications

MODELFXDQ20PDVE FXDQ25PDVE FXDQ32PDVE FXDQ40NDVE FXDQ50NDVE FXDQ63NDVE

FXDQ20PDVET FXDQ25PDVET FXDQ32PDVET FXDQ40NDVET FXDQ50NDVET FXDQ63NDVET

Power supply

with drain pump

without drain pump

Casing

Cooling capacity

Power consumption

Power consumption

Airflow rate (HH/H/L)

Sound level (HH/H/L) 1 3

(FXDQ-PD/NDVET) 1

(FXDQ-PD/NDVE) 1

External static pressure

Machine weight

Dimensions (H×W×D)

Piping connections

Gas (Flare)

Drain

Liquid (Flare)

Btu/h

kW

Heating capacityBtu/h

kW

kW

kW

m3/min

dB(A)

Pa

kg

mm

mm

cfm

1-phase, 220-240 V/220 V, 50/60 Hz

7,500 9,600 12,300 15,400 19,100 24,200

2.2

8,500

2.5

2.8

10,900

3.2

3.6

13,600

4.0

4.5

17,100

5.0

5.6

21,500

6.3

7.1

27,300

8.00.086 0.089 0.160 0.165 0.181

0.067 0.070 0.147 0.152 0.168

0.067 0.070 0.147 0.152 0.168

Galvanised steel plate8.0/7.2/6.4 10.5/9.5/8.5 12.5/11.0/10.0 16.5/14.5/13.0

28/26/2428/26/23 30/28/26 33/30/27 33/31/2930-10 44-15

23 27 28 31

6.4 9.5

12.7 15.9

VP20 (External Dia. 26/Internal Dia. 20)

200×700×620 200×1,100×620200×900×620

282/254/226 371/335/300 441/388/353 583/512/459

Cooling

0.067 0.070 0.147 0.152 0.168

Cooling

Heating

Cooling

Heating

Only 450 mm

700 mm**For FXDQ20-32SP models

FXDQ-PD/NDVE: with a drain pump (750 mm lift) as a standard accessoryFXDQ-PD/NDVET: without a drain pump

*1,100 mm in width for the FXDQ63ND model.

FXDQ40/50ND

200 mm200 mm

900 mm

200 mm

Only 700 mm

FXDQ20-32PD

Great forhotel use!

Great for residential use

Slim Duct (Standard) Type Slim Duct (Compact) Type

Side view Top view

240 mmandabove

Ceiling

700 mm

600

mm

200 mm 450 mm

• Drain pump is equipped as standard accessory with 750 mm lift.

2 2

2 2 2

155 156

Ind

oo

r U

nit

s

VRV Indoor Units

Air suction

JoistAir conditioner

ceiling

Middle Static Pressure Duct Type

Installation flexibility

Slim design

• With a height of only 245 mm, installation is possibleeven in buildings with narrow ceiling spaces.

Design flexibility

Adjustable external static pressure

• Using a DC fan motor, the external static pressure can be controlled within a range of 30 Pa* to 150 Pa.

Easy installation

“Airflow rate auto adjustment function” at field setting (local setting by remote controller)

Comfort• Control of the airflow rate can be selected from 3-step control. Auto airflow rate control can be

selected with wired remote controller.

• Lower sound level: down to 28 dB(A)

Standard DC drain pump

• DC drain pump is equipped as standard accessory with 850 mm lift.

Bottom suction possible

FXSQ-PA

Middle static pressure and slim design allow flexible installations

SpecificationsMODEL FXSQ20PAVE FXSQ25PAVE FXSQ32PAVE FXSQ40PAVE FXSQ50PAVE

FXSQ63PAVE FXSQ80PAVE FXSQ100PAVE FXSQ125PAVE FXSQ140PAVE

Power supply

Btu/h

kW

kW

m3/min

Pa

cfm

mm

mm

kg

dB(A)

Cooling capacity

Btu/h

kWHeating capacity

Power consumption

Casing

Airflow rate (H/M/L)

External static pressure

Sound level (H/M/L)

Dimensions (H×W×D)

Machine weight

Machine weight

Piping connections

Liquid (Flare)

Gas (Flare)

Drain

MODEL

Power supply

Btu/h

kW

kW

m3/min

Pa

cfm

mm

mm

kg

dB(A)

Cooling capacity

Btu/h

kWHeating capacity

Power consumption

Casing

Airflow rate (H/M/L)

External static pressure

Sound level (H/M/L)

Dimensions (H×W×D)

Piping connections

Liquid (Flare)

Gas (Flare)

Drain

1-phase, 220-240 V/220 V, 50/60 Hz

1-phase, 220-240 V/220 V, 50/60 Hz

19,100 7,500 9,600 12,300 15,400 5.62.2

8,5002.5

2.810,900

3.2

3.613,600

4.0

4.521,50017,100

6.35.00.075*10.066*1 0.101*10.058*1

kW 0.070*10.061*1 0.096*10.053*1

Galvanised steel plate

Galvanised steel plate

17/14.5/11.59/7.5/6.5 9.5/8/7 15/12.5/10.5

34/32/30

6.4

12.7

36/33/30 34/32/2933/30/28

335/282/247 530/441/371 600/512/406318/265/230

741/618/512 812/688/565 1,130/953/794 1,306/1,112/918 1,377/1,183/988

30-150 (50) *2 50-150 (50) *2

27 35

35

25245×700×800 245×1,000×800

245×1,000×800

245×550×800

VP25 (External Dia. 32/Internal Dia. 25)

VP25 (External Dia. 32/Internal Dia. 25)

24,200 30,700 38,200 47,800 54,600

7.1 9.027,300 34,100

8.0 10.0

11.2

12.5

14.042,700 54,600

16.0

16.061,400

18.00.106*1 0.126*1 0.151*1 0.206*1 0.222*1

kW 0.101*1 0.121*1 0.146*1 0.201*1 0.217*1

21/17.5/14.5 23/19.5/16 32/27/22.5 37/31.5/26 39/33.5/28

37.5/34/3036/32/29 39/35/32 42/38.5/35 43/40/36

50-140 (50) *250-150 (50) *2

245×1,400×800 245×1,550×80037 46 47 52

9.515.9

Cooling

Heating

Cooling

Heating

245 mm

Adjustable external static pressure

* 30 Pa–150 Pa for FXSQ20-40PAVE50 Pa–150 Pa for FXSQ50-125PAVE50 Pa–140 Pa for FXSQ140PAVE

Easy maintenance• Inspection and cleaning is facilitated by separating the drain pipe

and inspection opening and by the drain pan maintenance check hole.

Drain pan maintenance check hole

Separate drain pipe and inspection opening

Rated airflow

Exte

rnal

sta

tic

pre

ssu

re (

ESP)

Airflow

*This function can only be set via wired remote controller.

Silver ion anti-bacterial drain pan

Filter has anti-mould and antibacterial treatment

• Prevents the growth of slime, bacteria, and mould that cause odours and clogging.* Drain pan should be changed once every two to three years.

Cleanliness

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB,

Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.

• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)

• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.During actual operation, these values are normally somewhat higher as a result of ambient conditions.

*1: Power consumption values are based on conditions of rated external static pressure.

*2: External static pressure can be modified using a remote controller that offers thirteen (FXSQ20-40PA), eleven (FXSQ50-125PA) or ten (FXSQ140PA) levels of control. These values indicate the lowest and highest possible static pressures. The rated static pressure is 50 Pa.

<Mechanism>1. During field setting, power input of DC fan is detected. 2. External static pressure is estimated from power input of DC fan because PCB

of FXSQ-PA has table of external static pressure vs. power input of DC fan.3. Actual duct resistance is calculated according to 1 and 2.4. Fan speed is automatically adjusted to produce rated airflow.

• Bottom suction is possible which facilitates installation and maintenance. Wiring connections and maintenance of control box can be done from under the unit with an optional shield plate for side plate.

30Pa* 150Pa

Duct resistance at designing system

Actual duct resistance

rpm 1

rpm 2

rpm 8

rpm 7

Notes: ”Airflow rate auto adjustment function” can be adjusted within ±10% of rated airflow. (Refer to Engineering Data Book for details)

”Airflow rate auto adjustment function” should be used at field setting only.

Systemoperation

Installation

Installation

Design

Design

Field setting without “airflow rate auto adjustment function”

Field setting with “airflow rate auto adjustment function” by remote controller

Various adjustments are required (Due to excess or deficiency of airflow) e.g. Duct re-construction, Motor replacement, Damper replacement, etc.

InnovatingFunction!

157 158

Ind

oo

r U

nit

s

VRV Indoor Units

mm

Middle-High Static Pressure Duct Type

Design flexibility

FXMQ-PA

Middle and high static pressure allows for flexible duct design

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation,

these values are normally somewhat higher as a result of ambient conditions.*1: Power consumption values are based on conditions of rated external static pressure.*2: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32PA), thirteen (FXMQ40PA), fourteen (FXMQ50-125PA) or

ten (FXMQ140PA) levels of control. These values indicate the lowest and highest possible static pressures. The rated static pressure is 50 Pa for FXMQ20-32PA and 100 Pa for FXMQ40-140PA.

SpecificationsMODEL FXMQ20PAVE FXMQ25PAVE FXMQ32PAVE FXMQ40PAVE FXMQ50PAVE

Power supply 1-phase, 220-240 V/220 V, 50/60 Hz

Cooling capacity

Heating capacity

Btu/h

kW

Btu/h

kW

kW

kW

7,500 9,600 12,300 15,400 19,100

2.2 2.8

8,500 10,900

2.5 3.2

3.6 4.5

13,600 17,100

4.0 5.0

5.6

21,500

6.3

Power consumption0.056 *1 0.060 *1 0.151 *1 0.128 *1

0.044 *1 0.048 *1 0.139 *1 0.116 *1

Galvanised steel plateCasing

Airflow rate (HH/H/L)m3/min 9.5/8/79/7.5/6.5 16/13/11 18/16.5/15

318/265/230cfm 635/582/530565/459/388335/282/247

External static pressure Pa 30-100 (50) *2 30-160 (100) *2 50-200 (100) *2

dB(A)

kg

mm

Sound level (HH/H/L)

Machine weight

Dimensions (H×W×D)

34/32/3033/31/29 39/37/35 41/39/37

300x700x700 300x1,000x700300x550x700

27 3525

Piping connections

Gas (Flare)

Drain

Liquid (Flare)

kWPower consumption

Casing

Airflow rate (HH/H/L)m3/min

cfm

External static pressure Pa

dB(A)

kg

mm

mm

Sound level (HH/H/L)

Machine weight

Dimensions (H×W×D)

Piping connections

Gas (Flare)

Drain

Liquid (Flare)

6.4

12.7

VP25 (External Dia. 32/Internal Dia. 25)

MODEL FXMQ63PAVE FXMQ80PAVE FXMQ100PAVE FXMQ125PAVE FXMQ140PAVE1-phase, 220-240 V/220 V, 50/60 HzPower supply

Cooling capacity

Heating capacity

Btu/h

kW

Btu/h

kW

24,200 30,700 38,200 47,800 54,600

7.1

27,300

8.0

9.0

34,100

10.0

11.2

42,70012.5

14.0

54,600

16.0

16.0

61,40018.0

0.138 *1 0.185 *1 0.215 *1 0.284 *1 0.405 *1

kW 0.127 *1 0.173 *1 0.203 *1 0.272 *1 0.380 *1

Galvanised steel plate

19.5/17.5/16 25/22.5/20 32/27/23 39/33/28 46/39/32

883/794/706 1,130/953/812 1,377/1,165/988 1,624/1,377/1,130688/618/56550-140 (100) *2 50-200 (100) *2

42/40/38 43/41/39 44/42/40 46/45/43

300×1,400×700300×1,000×700

4535 46

9.5

15.9

VP25 (External Dia. 32/Internal Dia. 25)

Cooling

Heating

Cooling

Heating

Using a DC fan motor, the external static pressure canbe controlled within a range of 30 Pa* to 200 Pa*.

Easy maintenanceInspection and cleaning is facilitated by separating the drain pipe and inspection opening and by the drain pan maintenance check hole.

• All models are only 300 mm in height and the weight of the FXMQ40-140PA has been reduced.• Drain pump is equipped as standard accessory with 700 mm lift.

Comfort• Control of the airflow rate can be selected from 3-step control and Auto. Auto airflow rate control can

be selected with wired remote controller.

• Low operation sound level: down to 29 dB(A)

Energy saving• DC fan motor is used to realise energy-saving operation.

Adjustable external static pressure

*30 Pa – 100 Pa for FXMQ20PA-32PA*30 Pa – 160 Pa for FXMQ40PA*50 Pa – 200 Pa for FXMQ50PA-125PA*50 Pa – 140 Pa for FXMQ140PA

30Pa* 200Pa

Easy installation“Airflow rate auto adjustment function” at field setting (local setting by remote controller)

Rated airflow

Exte

rnal

sta

tic

pre

ssu

re (

ESP)

Airflow

*This function is not available with FXMQ140PAVE.*This function can only be set via wired remote controller.

<Mechanism>1. During field setting, power input of DC fan is detected. 2. External static pressure is estimated from power input of DC fan because PCB of

FXMQ-PA has table of external static pressure vs. power input of DC fan.3. Actual duct resistance is calculated according to 1 and 2.4. Fan speed is automatically adjusted to produce rated airflow.

Duct resistance at designing system

Actual duct resistance

rpm 1

rpm 2

rpm 8

rpm 7 Systemoperation

Installation

Installation

Design

Design

Field setting without “airflow rate auto adjustment function”

Field setting with “airflow rate auto adjustment function” by remote controller

Various adjustments are required (Due to excess or deficiency of airflow) e.g. Duct re-construction, Motor replacement, Damper replacement, etc.

InnovatingFunction!

Drain pan maintenance check hole

Separate drain pipe and inspection opening

Silver ion anti-bacterial drain pan

Filter has anti-mould and antibacterial treatment

Prevents the growth of slime, bacteria, and mould that cause odours and clogging.*Drain pan should be changed once every two to three years.

Cleanliness

Notes: ”Airflow rate auto adjustment function” can be adjusted within ±10% of rated airflow. (Refer to Engineering Data Book for details)”Airflow rate auto adjustment function” should be used at field setting only.

159 160

Ind

oo

r U

nit

s

VRV Indoor Units

High Static Pressure Duct TypeEasy maintenance

Adjustable external static pressure

• Using a DC fan motor, the external static pressure can be controlled within a range of 50 Pa to 250 Pa.

Built-in pre-filter slot

• To cater for easy installation of filter at site, a filter rail is available at the return flange.

FXMQ-P

High static pressure allows for flexible duct design.• Inspection and cleaning is facilitated by separating

the inspection opening and the drain pan maintenance check hole.

• Heat exchanger, drain pan and fan deck can be easilyaccessed and removed from bottom for maintenance.

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)• Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.*1: Power consumption values are based on conditions of rated external static pressure.*2: External static pressure can be modified using a remote controller that offers fifteen levels of control.

These values indicate the lowest and highest possible static pressures. The standard static pressure is 150 Pa.

Design flexibility

Easy installation

Adjustable external static pressure

50Pa 250Pa

SpecificationsMODEL FXMQ200PVM FXMQ250PVM

1-phase, 220-240 V/220-230 V, 50/60 Hz

76,400 95,500

22.4 28.0

0.55 *1 0.67 *1

Galvanised steel plate

74/61/50 84/71/58

2,612/2,153/1,765 2,965/2,506/2,047

50-250 (150) *2 50-250 (150) *2

42/38/35 44/40/37

470×1,490×1,100 470×1,490×1,100

95 105

BSP1”

Power supply

Cooling capacityBtu/h

kW

85,300 107,500

25.0 31.5Heating capacity

Btu/h

kW

kW

m3/min

cfm

dB(A)

mm

kg

mm

Power consumption

Casing

Liquid (Flare)

Gas (Flange)

Drain

Cooling

Heating

Airflow rate (HH/H/L)

Sound level (HH/H/L)

PaExternal static pressure

Dimensions (H × W × D)

Machine weight

Piping connections

9.5

22.219.1

0.54 *1 0.65 *1

Drain pan maintenance check hole

Separate inspection opening

“Airflow rate auto adjustment function” at field setting (local setting by remote controller)

Rated airflow

Exte

rnal

sta

tic

pre

ssu

re (

ESP)

Airflow

*This function can only be set via wired remote controller.

<Mechanism>1. During field setting, power input of DC fan is detected. 2. External static pressure is estimated from power input of DC fan because PCB

of FXMQ-P has table of external static pressure vs. power input of DC fan.3. Actual duct resistance is calculated according to 1 and 2.4. Fan speed is automatically adjusted to produce rated airflow.

Duct resistance at designing system

Actual duct resistance

rpm 1

rpm 2

rpm 8

rpm 7 Systemoperation

Installation

Installation

Design

Design

Field setting without “airflow rate auto adjustment function”

Field setting with “airflow rate auto adjustment function” by remote controller

Various adjustments are required (Due to excess or deficiency of airflow) e.g. Duct re-construction, Motor replacement, Damper replacement, etc.

InnovatingFunction!

Notes: ”Airflow rate auto adjustment function” can be adjusted within ±10% of rated airflow. (Refer to Engineering Data Book for details)”Airflow rate auto adjustment function” should be used at field setting only.

161 162

Ind

oo

r U

nit

s

VRV Indoor Units

4-way flow 3-way flow L-shaped 2-way flow

4-way Flow Ceiling Suspended Type Ceiling Suspended TypeFXUQ-A

Slim and stylish design, optimum air distribution, installation without ceiling cavity

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.

• Unit body and suction panel have round shapes that form a slim design, that fits various locations such as the ceilings without cavity.

• Flaps close automatically when the unit stops, which gives a simple appearance.

• All models have a unified slim height of 198 mm that gives a similar impression even when models with different capacities are installed in the same area.

ComfortSlim and stylish design

• Airflow direction adjustment can be individually adjusted for each air discharge outlet to deliver optimal air distribution. 5 directions of airflow and auto-swing can be selected with wired remote controller BRC1E63.

• Control of the airflow rate can be selected from 3-step control. Auto airflow rate control can be selected with wired remote controller.

Comfort

• Drain pump is equipped as a standard accessory with 600 mm lift.

• Depending on installation site requirements or room conditions, 2-way, 3-way and 4-way discharge patterns are available.

Flexible installation

FXHQ-MA / A

Slim body with quiet and wide airflow

FXHQ32MAVE FXHQ63MAVE FXHQ100MAVE FXHQ125AVM FXHQ140AVM

6.4

12.7

12,300

3.6

13,600

4.0

12/-/10

36/-/31

424/-/353

195×960×680

24

0.111

1-phase, 220-240 V/220 V, 50/60 Hz

White (10Y9/0.5)

24,200

7.1

27,300

8.0

0.115

17.5/-/14

39/-/34

618/-/494

195×1,160×680

28

9.5

15.9

VP20 (External Dia. 26/Internal Dia. 20)

38,200

11.2

48,000

14.1

42,700

12.5

54,600

16.0

0.135

0.111 0.115 0.135

25/-/19.5

45/-/37

883/-/688

195×1,400×680

33

Specifications

1-phase, 220-240 V/220-230 V, 50/60 Hz

52,900

15.5

58,000

17.0

0.168

0.168

0.181

0.181

Sheet Metal / White

34/26/20

1,200/918/706

46/41/37

36/27/20

1,271/953/706

48/42/37

235×1,590×690

41

MODEL

Power supply

Cooling capacityBtu/h

kW

Heating capacityBtu/h

kW

kW

m3/min

cfm

dB(A)

mm

kg

mm

Power consumption

Casing

Liquid (Flare)

Gas (Flange)

Drain

Cooling

Heating

Airflow rate (H/M/L)

Sound level (H/M/L)

Dimensions (H × W × D)

Machine weight

Piping connections

FXHQ32 / 63 / 100MA FXHQ125 / 140A

• Auto swing (up and down) and louvers (left and right by hand) bring comfort to the room.

• Louver manually adjusts for straight or wide angle airflow.

Installation flexibility• Flexible installation

The unit fits more snugly into tight spaces.

• Drain pump kit (option) can be easily incorporated.Drain pipe connection can be done inside the unit. Refrigerant and drain pipe outlets are at the same opening.

• All wiring and internal servicing can be done from under the unit.

• The technology of the DC fan motor, wide sirocco fan, and large heat exchanger combine for greater airflow and quiet operation.

• Sophisticated design: Flap neatly closes when not in use.

• Suitable for high ceilings: maximum 4.3 m

• Control of airflow rate has been improved from 2-step to 3-step.

• Drain pump kit (option) includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging.

• The rear side removable frame allows ease of access for piping work.

New 125 / 140 models provide greater capacity for large spaces

30 or more 30 or moreRequired installation space (mm)

* Water used in the test-run can be drained from the air discharge opening rather than from the side as was formerly the case.

SpecificationsMODEL FXUQ71AVEB FXUQ100AVEB

Power supply

Casing

Cooling capacity

Heating capacity

Btu/h

kW

Btu/h

kW

kW

kWPower consumption

cfmAirflow rate (H/M/L)

m3/min

Sound level (H/M/L) dB(A)

Machine weight kg

Dimensions (H×W×D) mm

Piping connections

mmGas (Flare)

Drain

Liquid (Flare)

1-phase, 220-240 V/220-230 V, 50/60 Hz

27,300

8.0

0.090

22.5/19.5/16

794/688/565

40/38/36

26

9.5

15.9

38,200

11.2

30,700

9.0

42,700

12.50.200

0.073 0.179

31/26/21

Fresh white

1,094/918/741

47/44/40

27

198×950×950

VP20 (External Dia. 26/Internal Dia. 20)

Cooling

Heating

Silver ion anti-bacterial drain pan

Filter has anti-mould and antibacterial treatment

• Prevents the growth of slime, bacteria, and mould that cause odours and clogging.* Drain pan should be changed once every two to three years.

Cleanliness

Drain pump kit (built inside the unit)

600 mm

Easier piping work

Notes:Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB,

Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.

• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)

• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. During actual operation, these values are normally somewhat higher as a result of ambient conditions

163 164

Ind

oo

r U

nit

s

VRV Indoor Units

Wall Mounted Type

Higher airflow

Lower sound level

• An invisible air intake at the top of the unit

• Vertical auto-swing enables efficient air and temperature distribution throughout the room.

• The louver closes automatically when the unit stops.

• Enhanced comfort is achieved.

• 5 step discharge angles can be set by remote controller.

• Discharge angle is automatically set at the same angle as previous operation when restart.

Whisper quiet in operation, with sound levels as low as 28.5 dB(A)**Sound level for FXAQ20-32A

An ideal solution for a wide range of commercial spaces, including individual office spaces.

FXAQ-A

Stylish flat panel design harmonised with your interior décor

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)• Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.

External EV kit (for heating operation) (Option)

Specifications

1-phase, 220-240 V/220-230 V, 50/60 Hz

FXAQ20AVM

Resin / White N9.5

FXAQ25AVM FXAQ32AVM FXAQ40AVM FXAQ50AVM FXAQ63AVMMODEL

Power supply

Cooling capacityBtu/h

kW

Heating capacityBtu/h

kW

kW

m3/min

cfm

dB(A)

mm

kg

mm

Power consumption

Casing

Liquid (Flare)

Gas (Flange)

Drain

Cooling

Heating

Cooling

Heating

Airflow rate (H/L)

Sound level (H/L)

Dimensions (H × W × D)

Machine weight

Piping connections

7,500

2.2

0.040

9.1/7.0

34.0/28.5

9,600

2.8

0.040

12,300

3.6

0.050

332/247321/247

9.4/7.0

36.0/28.5

290×795×266

12

346/247

9.8/7.0

38.5/28.5

6.4

VP13 (External Dia. 18/Internal Dia. 15)

12.7

15,400

4.5

0.050

431/342

12.2/9.7

38.0/33.5

19,100

5.6

0.070

530/424

15.0/12.0

42.0/35.5

290×1,050×269

15

24,200

8,500 10,900 13,600 17,100 21,500 27,300

2.5 3.2 4.0 5.0 6.3 8.0

7.1

0.110

0.040 0.040 0.040 0.050 0.060 0.100

671/494

19.0/14.0

47.0/38.5

33.0/28.5 35.0/28.5 37.5/28.5 37.0/33.5 41.0/35.5 46.5/38.5

9.5

15.9

Drain pump kit

1,000mm

Height of drain-up

Indoor unit

This product, which is concealed in ceilings or corridors for quieter heating operation, is used to connect indoor units in places where quiet environment is required such as residential living rooms.

* This option is only effective for reducing operation sound during heating operation. Therefore it is ineffective when connected to cooling only outdoor units.

Gas pipe

Liquid pipe

Max 4 m

External EV kit(for heating operation)BEV15/30D

5 m - 10 m

An invisible air intake at the top of the unit

Comfort

Stylish design and cleanliness• Stylish flat panel design creates a graceful harmony that enhances any interior space.

• Flat panel can be cleaned with only the single pass of a cloth across their smooth surface.Flat panel can also be easily removed and washed for more thorough cleaning.

• Drain pan and air filter can be kept clean by mould-proof polystyrene.

Flexible installation• Drain pipe can be fitted to from either left or right sides.

• Drain pump kit is available as optional accessory, which lifts the drain 1,000 mm from the bottom of the unit.

165 166

Ind

oo

r U

nit

s

VRV Indoor Units

Floor Standing TypeFXLQ-MA

Suitable for perimeter zone air conditioning

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.

During actual operation, these values are normally somewhat higher as a result of ambient conditions.

• Floor Standing types can be hung on the wall for easier cleaning. Running the piping from the back allows the unit to be hung on walls. Cleaning under the unit, where dust tends to accumulate, is considerably easier.

• The adoption of a fibre-less discharge grille featuring an original design to prevent condensation also helps prevent staining and makes cleaning easier.

• A long-life filter (maintenance free up to one year*) is equipped as standard accessory.*8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

FXNQ-MA

Designed to be concealed in the perimeter skirting-wall

• The unit is concealed in skirting-wall of perimeter, that enables to create high class interior design.

• The connecting port faces downward, greatly facilitating on-site piping work.

• A long-life filter (maintenance free up to one year*) is equipped as standard accessory.*8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3

MODEL

Specifications

Power supply

Cooling capacity

Heating capacity

Btu/h

kW

Btu/h

kW

kW

Power consumption

220 V

240 V

m3/min

Casing

Airflow rate (H/L)

Sound level (H/L)

Machine weight

Dimensions (H × W × D)

Piping connections

kg

mm

mmGas (Flare)

Drain

Liquid (Flare)

dB(A)

cfm

FXLQ20MAVE

7,500

2.2

FXLQ25MAVE

9,600

2.8

8,500

2.5

10,900

3.2

0.049

7/6

35/32

37/34

25

600×1,000×222

247/212

FXLQ32MAVE

12,300

3.6

8/6

282/212

6.4

12.7

FXLQ40MAVE

15,400

4.5

0.090

11/8.5

38/33

40/35

30

600×1,140×222

388/300

FXLQ50MAVE

19,100

5.6

14/11

39/34

41/36

494/388

FXLQ63MAVE

24,200

7.1

13,600

4.0

17,100

5.0

21,500

6.3

27,300

8.0

0.110

kW 0.049 0.090 0.110

16/12

40/35

42/37

36

600×1,420×222

565/424

9.5

15.9

1-phase, 220-240 V/220 V, 50/60 Hz

Ivory white (5Y7.5/1)

21O.D.

Cooling

Heating

SpecificationsMODEL FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE

Power supply

Cooling capacity

Heating capacity

Btu/h

kW

Btu/h

kW

kW

kW

Cooling

Heating

Power consumption

220 V

240 V

m3/min

Casing

Airflow rate (H/L)

Sound level (H/L)

Machine weight

Dimensions (H × W × D)

Piping connections

kg

mm

mmGas (Flare)

Drain

Liquid (Flare)

dB(A)

cfm

7,500

2.2

8,500

2.5

7/6

19.0

247/212

9,600

2.8

10,900

3.2

0.049

0.049

7/6

35/32

37/34

610×930×220

247/212

12,300

3.6

13,600

4.0

8/6

610×1,070×220

282/212

6.4

12.7

15,400

4.5

17,100

5.0

0.090

0.090

11/8.5

38/33

40/35

23.0

388/300

19,100

5.6

21,500

6.3

14/11

39/34

41/36

610×1,350×220

494/388

24,200

7.1

27,300

8.0

0.110

0.110

16/12

40/35

42/37

27.0

565/424

9.5

15.9

1-phase, 220-240 V/220 V, 50/60 Hz

21O.D.

Galvanised steel plate

Concealed Floor Standing Type

167 168

Ind

oo

r U

nit

s

VRV Indoor Units

Duct connection airflow type Direct airflow type

All-fresh (using outdoor air only) system Return + Outdoor air mixed system

Outside Air conditioning

Outdoor air introduction

Air conditioning

Circu

lated air

Outdoor air introduction

Outside

* Air introduced from the outside and circulated air must be mixed in the air conditioner primary side before introduction into the air conditioner.

Floor Standing Duct Type Spot Air ConditionerFXVQ-N

Large airflow type for large spaces

FXPQ-A

Personal air comfort delivered to large spaces

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)*1: Sound level : measured when the air discharge outlet duct (2 m) is attached (anechoic chamber conversion value).

It increases by approximately 5 dB(A) when the plenum chamber is installed to deliver direct airflow.*2: The value is the external static pressure with standard pulley.

Large airflow rate

• Full-scale duct connection airflow allows for air conditioning evenly in spacious areas.

• Adding the plenum chamber (option) allows for simple operation with direct airflow.*Note that the operation sound increases by approximately 5dB(A).

• The belt drive system allows for use of air discharge outlets in various shapes as well as long ducts.

• A long-life filter (maintenance free up to one year*) is equipped as a standard accessory. *8 hr/day, 26 day/month. For dust concentration of 0.15 mg/m3

• A wide range of optional accessories are available such as high-efficiency filters.

• Outdoor air intake mode is useable as an outdoor-air processing air conditioner.*When using the unit as an outdoor-air processing unit, there are some restrictions. Strictly follow the restrictions specified in the Engineering Data Book.

Rp1 (PS 1B internal thread)

Long-life filter (anti-mould resin net)

Belt drive system

3-phase 4-wire system, 380–415 V, 50 Hz

Ivory white (5Y7.5/1)

FXVQ125NY1

15.9 (Brazing)

52

118

1,670×750×510

FXVQ250NY1 FXVQ400NY1 FXVQ500NY16

62

281

65

236

1,900×1,170×720

12.7 (Brazing)

FXVQ200NY1

0.53

14.0

47,800

22.4

76,400

16.0

54,600

25.0

85,300

28.0

95,500

31.5

107,500

45.0

50.0

154,000

171,000

1.61 3.97 2.62

390

6,072

172

5.5

66

306

4.701.33

22.2 (Brazing)

60

169

1,670×1,170×510

19.1 (Brazing)

9.5 (Brazing)

56

144

1,670×950×510

FXVQ500NY1

191,000

56.0

215,000

63.0

1,900×1,470×720

15.9 (Brazing)

0.75

43

1,518

152

1.5

69

2,436

217

86

3,036

281

3.7

134

4,730

420

165

5,825

142

mm

kg

dB(A)

mm

mm

mm

kW

m3/min

cfm

Pa

kW

0.53 1.61 3.97 2.62 4.701.33kW

kW

Btu/h

kW

Btu/h

Liquid

Gas

Drain

Type

Motor output

Airflow rate

External static pressure *2

Drive system

Casing colour

Sound level *1

Dimensions (H × W × D)

Machine weight

Piping connections

Power supply

Cooling capacity

Heating capacity

MODEL

Air filter

Fan

28.6 (Brazing)

Power consumption

Specifications

Heating

Coolingkcal/h

Btu/h

kW

kcal/h

Btu/h

kW

kW

kW

m3/min

cfm

Pa

dB(A)

mm

kg

mm

mm

mm

L/h

Liquid (Flare)

Gas (Flare)

Drain

Drain water

Casing

External static pressure (H)

Sound level (H)

Dimensions (H × W × D)

Machine weight

Airflow rate (H-L)

Power supply

Cooling capacity

Heating capacity

MODEL

Piping connections

Power consumption

Specifications

Heating

Cooling

1 phase, 220 V, 50/60 Hz

2,400

9,600

2.8

2,800

10,900

3.2

0.120/0.132

0.120/0.132

Fresh White (N9.3)

15-12/15-11

530-424/530-388

5/20

55

455 x 555 x 470

32

6.4

12.7

SGP20A (External Dia. 27.2/Internal Dia. 21.6)

8

FXPQ25AVN

* 1 In-house comparison testing

New type indoor units distribute large volumes of air even further. Depend-ing on use, extension ducts can also be connected and used.

Withstands oil mistsFor the heat exchanger cooling pipe, a material with 3 to 6 times*1 the durability of standard materials has been selected.

Condensation suppressionTo minimize condensation, the air duct and blowout tubes are double insulated. This enables use in kitchens and other highly humid environments.

Leakage failsafeAn emergency reservoir is fitted in the underframe beneath the drain pan. This provides reassuring backup against drain pan overflow.

Extended operating periodFor durability over the long term, the units are fitted with fan motors that can operate for about 40,000 hours.

Simple maintenanceEasy maintenance design includes front access for fan motor replacement.

Large propeller fan ensures a gentle, pleasant airflow.

Uses propeller fan

*Performance of this indoor unit is certified when used within 1 m from the outlet.

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor

temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.

• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.(See Engineering Data Book for details.)

• Sound level: Anechoic chamber conversion value, measured at a point 1.0 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

• Power consumption values are based on conditions of rated external static pressure.

Flexible installation corresponds to site conditions. With temperature control available for each unit, air conditioning adjusts to individual preferences for personal air comfort.

169 170

Ind

oo

r U

nit

s

VRV Indoor Units

Clean Room Air ConditionerFXB(P)Q-P

Suitable for hospitals and other clean spaces

Notes: Specifications are based on the following conditions;• Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.• Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.)*1: An intake air filter is only attached to the ceiling intake type. *2: HEPA filter sold separately. The dust collection efficiency of HEPA filter is 99.97%. However, air may slightly leak around the filter when installing.*3: Weight including HEPA filter and panel. *4: Anechoic chamber conversion value under JIS B 8616 test conditions. Value usually increases slightly in practice due to surrounding conditions. *5: The clean room air conditioner does not support DOP testing (leak test) based on GMP standards

(Standards for Manufacturing Control and Quality Control for Medical Devices ) due to slight leakage at time of product installation. *6: Weight including panel. *In the case of an installation in an operating theatre etc. where an air conditioner malfunction may have serious consequences, please build in redundancy with two or more outdoor units.

Class 10,000 clean room condition achieved with a HEPA filter (sold separately)Filtration

Easily provides the high cleanliness environment required by various industries

Daikin’s clean room air conditioners are specially designed to achieve an environment cleanliness class 10,000. These air conditioners easily realize a cleanliness-class environment and help create a proper environment of hospitals, food and beverage factories, electronics factories, and other spaces that require clean air.

Select the air flow system and installation method to match the layout and purpose of the room

Two types of clean room air conditioners are available – an integrated unit model and a separate outlet unit model.It is also possible to configure the air flow system to ceiling intake or floor-level intake according to the panel selected.This flexible design enables the air conditioner to easily adopt to any room layout or use.

The low pressure-loss HEPA filter (sold separately) demonstrates superior dust filtering performance and easily accomplishes an air cleanliness of class 10,000.

Prevents uncomfortable drafts with a low flow speed of approximately 0.5 m/sThe floor-level intake system has a low flow speed of approximately 0.5 m/s.

Suppresses the propagation of bacteria in the duct with a proprietary antibacterial coating Antibacterial

The filter implements an antibacterial treatment with a new coating combining a silver-based inorganic antibacterial material (an organic antibacterial material that is effective against germs) that prevents mould. This enhances the antibacterial properties of the duct.An antibacterial treatment using a silver-based organic substance reduces mould.

Antibacterial fiber used in the intake filterWith a long-life filter employing anti-mould antibacterial fiber near the intake, cleaning performance is further enhanced.

Separate outlet unit model

FXBPQ63PVE

BAF82A63

24,200

7.1

26/22.5

918/794

BAFH82A63

120 *6

65 *3

492×1,078×1,300

BYB82A63WPBYB82A63CP

9.515.9

Integrated outlet unit model

Integrated with the indoor unitFXBQ40PVE FXBQ50PVE FXBQ63PVE

cfm

dB(A)

mm

kg

mm

kW

kWBtu/h

kWBtu/h

Model

Liquid (Flare)

Gas (Flare)

DrainHEPA filter

Ceiling intake type

Floor-level intake type

Power consumption

Intake filter efficiency *1

Indoor unit weight

Outlet HEPA filter efficiency *2

Casing

Dimensions (H×W×D)

Outlet unit weight

Piping connections

Filter(Option)

Panel(Option)

Power supply

Type

Cooling capacity

Heating capacity

MODEL

m3/min

kg

Indoor unit

Outlet unit

Sound level (H/L) *4

Airflow rate (H/L)

15,400 19,100

4.5 5.617,100 21,500

5.0 6.327,300

8.0

0.31

70% by gravimetric method

Galvanised steel plate

99.97% by DOP method *5

44/42

PT1B

140 *3

19.5/17.5

688/618

185 *3

492×1,788×1,000

BAFH82A50

BYB82A50C

BYB82A50W

492×1,788×1,300

BYB82A63WBYB82A63C

0.45

kW

Cooling

Heating 0.31 0.45

1-phase, 220-240 V/220 V, 50/60 Hz

6.412.7

Specifications

• Sufficient heating may not be achieved near the floor or at locations far from the outlet. • In the case of utilization in a hospital, some patients may be susceptible to cool drafts, so please ensure that they do not come directly under the outlet.• Install multiple units using two or more outdoor unit systems for installations to rooms such as operating rooms where the failure of the air

conditioner may have serious consequences.• In order to maintain static pressure in a room, the indoor fan continues to operate even when an abnormality occurs due to the thermostat shutting

off, defrost operation, protection device operation, or similar issue.• When incorporating outdoor air from the fresh air intake, install a damper or similar device to the duct routing and have it interlocked with the

indoor fan so that the outdoor air is shut out when the fan stops. The air that incorporates the suction filter may flow backward and allow dust trapped in the filter to return to the room.• When using gas to disinfect hospital operating rooms where this unit is installed, stop operation and cover the air inlet and outlet with plastic sheets

to prevent the gas from reaching and damaging the air conditioner.

• Locations in which heating of the lower part or the entire room is important.

• Locations necessitating a particularly high cleanliness factor and in which there are many people.

Warning

Because the ceiling intake type provides concentrated air conditioning that blows directly under the outlet. Accordingly, please be aware of the following.

Use the floor-level intake type in the following kind of locations.

* Please be aware that antibacterial products suppress the propagation of bacteria but do not have a sterilizing effect. Also, mould may grow in places where dust or soot accumulates.

* A material for which the registered safety was verified by Japanese chemicals and dangerous substances regulation law (Act on the Evaluation of Chemical Substances and Regulation of Their Manufacture, etc) is used for the antibacterial material.

* Periodic maintenance is required (such as cleaning the air filter and washing the inside to the unit).

Fan

Intake panel (punching metal)

Sheet steel drain pan

(antibacterial treated)

HEPA filter Outlet panel (punching metal)

Intake filter

Instances of installation by type (for a hospital)

* 1. Cleanliness class. A scale expressing the cleanliness of air established by NASA (National Aeronautics and Space Administration). Class 10,000 represents a state of less than 10,000 minute particles of diameter under 0.5 μm per cubic foot. For comparison, the cleanliness of a typical office is around class 1,000,000.

* 2. CCU (Cardiac Care Unit). A ward dedicated to the admission of patients with myocardial infarctions and other heart diseases. * 3. ICU (Intensive Care Unit). A ward for the careful treatment and nursing of patients with serious illnesses, injuries, or recovering from operations.

Ceiling intake type(high speed contracted flow/high ceiling model)

Floor-level intake type(gentle wind distribution/high cleanness class model)

Construction work is simple and a ceiling installation is possible. Dust filtering and air-conditioning can be started immediately.

Easy to increase the cleanness and air-conditioning effect. A low flow speed prevents drying of the affected part and the experience of drafts.

100,000 to 10,000

Type

Features

Cleanness class*1

Wind speed

Blow method

Integrated outlet unit

model

Separate outlet unit

model

10,000

1.0 m/s or higher Approximately 0.5 m/s

Outlet unit

Air conditioner Intake

(sourced locally)

Applications: Surgery prep rooms, recovery rooms, nurse stations, etc.

Applications: CCU*2, sterile rooms, etc.

Applications: Operating theatres, delivery rooms, etc.

Applications: Premature nurseries, newborn nurseries, ICU*3, etc.

Intake (sourced locally)

• Concentrated air conditioning centered directly under the unit• Easy installation

• Somewhat concentrated air conditioning centered directly under the outlet

• Can provide air conditioning in rooms with irregular shapes

• Total air conditioning with an emphasis on cleanliness

• Total air conditioning with an emphasis on cleanliness • Maintenance possible from a different room

* It may not be possible to maintain cleanliness in rooms with low air tightness.

171 172

Ind

oo

r U

nit

s

Residential Indoor Units

Slim Ceiling Concealed Duct Type Wall Mounted Type

Installation flexibility

Comfort

Efficiency & comfort

Stylish design

FDKS-EA/C(A), CDXS-EA, FDXS-C

Note: *The operation sound level values represent those for rear-suction operation and an external static pressure of 30 Pa for FDKS/CDXS-EA and 40 Pa for FDXS/FDKS/CDXS-C(A). Sound level values for bottom-suction operation can be obtained by adding 6 dB(A) for FDKS/CDXS-EA and 5 dB(A) for FDXS/FDKS/CDXS-C(A).

Elegant appearance with curved panel

FTKJ-N, FTXJ-N

• The sleek design of the FTKJ-N indoor unit features a uniquely European style. This elegant body houses state-of-the-art technology which delivers superior performance. The FTKJ-N series offers a versatile choice for home-owners, designers and architects alike.

Two-area intelligent eyeA combination of Comfort Airflow Mode and Intelligent Eye directs airflow away from people to avoid impacts. If there is no movement in a room for 20 minutes, Intelligent Eye automatically adjusts the set temperature by approximately 2°C to save energy.

Comfort Airflow ModeComfort Airflow Mode prevents uncomfortable impacts from blowing directly to a person’s body. During cooling operation, the flap moves upwards to prevent cold impacts.

3D Airflow3D Airflow combines Vertical and Horizontal Auto-Swing to reduce indoor temperature fluctuation. This function circulates air to every part of a room for uniform cooling, even for large spaces. To start 3D Airflow, push both the Vertical and Horizontal Auto-Swing buttons. The flaps and louvers swing in turn.

12.79.5

47/35/3245/29/2041/28/1946/35/3245/26/2038/25/19

12.4 (438)11.9 (420)10.4 (367)10.8 (381)10.6 (374)

12.79.5

8.3 (293)

46/35/2945/26/2038/25/1910.9 (385)8.9 (313)

1-phase, 220-240 V/220-230 V, 50/60 Hz

Standard accessoryStandard accessory

Note: Remote controllers other than the standard accessory wireless remote controller cannot be used.

Only 200 mm in height, this model can be installed in rooms with as little as 240 mm in height for the ceiling space between the drop-ceiling and ceiling slab.

• Home Leave Operation prevents large increase or decrease in the indoor temperature by continuing operation* while someone is sleeping or left the house. This means that an air-conditioned welcome awaits when someone wakes up or returns. It also means that the indoor temperature can quickly return to the preferred comfort setting.

200 mm

Only 700 mm

FDKS-EA, CDXS-EA

8.7 (307)

200X700X620 200X900X620 200X1,100X6203027

40

25

VP20 (External Dia. 26/Internal Dia. 20)Both liquid and gas pipes

21

30

9.5 (335) 10.0 (353) 12.0 (424)

37/33/3135/31/29

16.0 (565)

38/34/32

1-phase, 220-240 V/220-230 V, 50/60 Hz

5 steps, quiet and automaticMicrocomputer control

Power supply

Airflow rates (H) m3/min(cfm)

Sound levels (H/L/SL)* dB(A)

Fan speed

Temperature control

Dimensions (H × W × D) mm

kg

mm

Pa

Machine weight

Liquid (Flare)

Gas (Flare)

Drain

Pipingconnections

Heat insulation

External static pressure

9.5 6.4

12.7

CDXS25EAVMA CDXS35EAVMA FDXS25CVMA FDXS35CVMA FDXS50CVMA FDXS60CVMAMODEL

Cooling Only

Heat Pump

FDKS25EAVMB FDKS35EAVMB FDKS25CAVMB FDKS35CAVMB FDKS50CVMB FDKS60CVMB

Specifications

*Home Leave Operation can be selected for any temperature from 18 to 32˚C for cooling operation and 10 to 30˚C for heating operation.*Home Leave Operation function must be set using the remote controller when going to sleep or leaving the house, and after waking up or returning home.

240 mm

Notes: 1. To prevent an increase of the operation noise, avoid installing the air suction grille directly below the suction chamber.

2. Grilles, piping connections, ducts, and installation parts should be obtained locally. Slim Ceiling Mounted Duct type models do not have drain-up pumps.

3. The signal receiver unit must be located near the air suction inlet, because the unit includes a sensor that detects room temperature.

* Locally obtained partsAIR

AIR

Air suction grille*

Suction duct*

Signal receiver

Air discharge duct*

Suspension bolt*

Air discharge grille*

Signal receiver wireLength = 1,900 mm

Chamber

Air filter

Signals from the wireless remote controller aretransmitted to the signal receiver.

240 mm

FTXJ50NVMVSFTXJ50NVMVWFTXJ35NVMVSFTXJ35NVMVWFTXJ25NVMVSFTXJ25NVMVW

SilverWhiteSilverWhiteSilverWhite

SilverWhiteSilverWhiteSilverWhite

kgMachine weight

mmDimensions (H × W × D)

dB(A)Sound level (H/L/SL) Heating

Cooling

m3/min(cfm)Airflowrate (H) Heating

Cooling

mmPipingconnections

Drain

Gas

Liquid

Front panel colour

Power supply

Both liquid and gas pipes

12303x998x212

Microcomputer control5 steps, quiet and automatic

18.0

6.4

Heat insulation

Temperature control

Fan speed

Heat PumpMODEL

SpecificationsFTKJ50NVMVSFTKJ50NVMVWFTKJ35NVMVSFTKJ35NVMVWFTKJ25NVMVSFTKJ25NVMVWCooling Only

kgMachine weight

mmPipingconnections

Drain

Both liquid and gas pipes18.0

5 steps, quiet and automaticMicrocomputer control

303x998x212126.4

1-phase, 220-240 V/220-230 V, 50/60 Hz

Heat insulation

MODEL

Gas (Flare)

Liquid (Flare)

mmDimensions (H × W × D)

dB(A)Sound levels (H/L/SL)

m3/min(cfm)Airflow rates (H)

Temperature control

Fan speed

Front panel colour

Power supply

• Low operation sound level: down to 29 dB(A)

Slim and smooth design suits your shallow ceiling Elegant appearance with European style

Great forhotel use!

Residential Indoor Units

173 174

Ind

oo

r U

nit

s

BPMKS967A2BPMKS967A3

BP unit

Wall Mounted Type BP UnitsBP units for connection to residential indoor units

Efficiency & comfort

Cleanliness

FTKS-D/B/F, FTXS-D/E/F

Stylish flat panel harmonises with your interior décor

Note: *For Heat Pump type only.

Connectable to residential indoor units

• Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement, it adjusts the temperature by 2˚C for energy savings.

• Low sound level: down to 22 dB(A)

BP units allow VRV systems to be connected to Daikin’s stylish and quiet residential indoor units.

Quiet operating sound

Expansion valves tend to create refrigerant passing noise. However, this noise can be reduced by installing the valves in BP units. The units can be fitted inside the ceiling or roof-space far from an indoor unit.Some Daikin residential indoor units also provide minimum sound levels of just 19 dB(A).

Titanium Apatite Deodorising FilterWhile the filter’s micron-level fibres trap dust, titanium apatite effectively adsorbs odours and allergens, as well as deodorises odours.*This filter is not a medical device. Benefits such as the adsorption of odours and allergens and deodorisation of odours are only effective for substances which are directly attached to the Titanium Apatite Deodorising Filter.

• 3-D Airflow combines Vertical and Horizontal Auto-Swing to circulate air to every part of a room for uniform cooling of even large spaces.* This function is available for FTK(X)S50/60/71F.

Specifications

283×800×195 290×795×2389

8.7 (307) 8.9 (314) 14.7 (519) 16.2 (572) 17.4 (614)9.4 (332) 9.7 (342) 16.2 (572) 17.4 (614) 21.5 (759)

37/25/22 FTKS: 39/26/23FTXS: 38/26/23

FTKS: 43/34/31FTXS: 44/35/32

45/36/33 46/37/34

37/28/25 38/29/26

11.4 (402)–

44/35/32

– 42/33/30 44/35/32 46/37/34

1-phase, 220-240 V/220-230 V, 50/60 Hz

5 steps, quiet and automaticMicrocomputer control

Both liquid and gas pipes

White

6.4

18.0 9.5 12.7 15.9

290×1,050×23812

FTXS20DVMA FTXS25EVMA FTXS35EVMA FTXS50FVMA FTXS60FVMA FTXS71FVMAPower supply

Front panel colour

Airflow rates (H)

Cooling m3/min(cfm)

dB(A)

mm

kg

mm

Heating*

Cooling

Heating*

Sound levels (H/L/SL)

Fan speed

Temperature control

Dimensions (H × W × D)

Machine weight

Liquid (Flare)

Gas (Flare)

Drain

Pipingconnections

Heat insulation

MODELCooling Only

Heat Pump

FTKS25DVM FTKS35DVM FTKS50BVMA FTKS50FVM FTKS60FVM FTKS71FVM––

When you are in the room When you go out

A uniform temperature is achieved throughout the entire room.

Standardaccessory*

*Remote controllers other than the standard accessory wireless remote controller cannot be used.

Cooling Only

Heat Pump

FTKS25D / FTKS35D

FTXS20D / FTXS25E / FTXS35E

Cooling Only

FTKS50B

Cooling Only

Heat Pump

FTKS50F / FTKS60F / FTKS71F

FTXS50F / FTXS60F / FTXS71F

The BP units can be installed inside the ceiling.

Specifications

Note: *Total auxiliary piping length.

14.220.8

2 for power supply (including earth wiring), 2 for interunit wiring (outdoor unit-BP, BP-BP),

3 for interunit wiring (BP-indoor unit)

3 for power supply (including earth wiring), 2 for interunit wiring (outdoor unit-BP, BP-BP),

4 for interunit wiring (BP-indoor unit)

kWMax. rated capacity of connectable indoor

2.0

180X294 (+356*)X3500.0510

15.9X215.9X319.1X1

6.4X26.4X3

7.58

9.5X1

2 (connectable to 1-2 indoor units)3 (connectable to 1-3 indoor units)1-phase, 220-240 V/220-230 V, 50/60 Hz

kWMin. rated capacity of connectable indoor

kgMachine weight

mmDimensions (HXWXD)

ARunning current

WPower consumption

2.0 kW class to 7.1 kW classConnectable indoor units

Both liquid and gas pipesHeat insulation

kW

kW

Branch

MainGas

Branch

MainLiquid

Piping connections(Brazing)

Number of wiring connections

MODEL

Power supply

Number of ports

Min. sound level 19 dB(A)

175 176

Air

Han

dlin

g U

nit

/ A

ir T

reat

men

t Eq

uip

men

t

Air Treatment Equipment

Air Handling Unit Air Treatment Equipment

Integrate your air handling unit in a total solution for large sizespaces such as factories and large stores.

Daikin air handling units can be connected to VRV systems. This combination can be built to order as a system. Outdoor air series is also possible. Please contact your local sales office for details.

Liquid pipeGas pipeDaikin communication wire (F1, F2 communication)Other communication wire

System overview

Air handling unit

AHURCapacity range : 6 – 120 HP

Outdoor-AirProcessing Unit VKM-GAM Type VKM-GA Type VAM-GJ Type

Refrigerant Piping Connectable Not connectable

Wiring Connectable Connectable

After-cool &After-heat Control

Available Not available

— — —

Energy savings obtained

Fitted

Option Option

Air supply only Air supply & air exhaust

220-240 V, 50 Hz 220-240 V/220 V, 50 Hz/60 Hz

Heat Reclaim Ventilator

Connectionswith VRV systems

Connectable

Connectable

Available

Heat Exchange Element Energy savings obtained

Humidifier

High Efficiency Filter Option

Ventilation System Air supply & air exhaust

Power Supply 220-240 V, 50 Hz

Airflow Rate

150 m3/h250 m3/h350 m3/h500 m3/h650 m3/h800 m3/h

1080 m3/h 1000 m3/h

500 m3/h

800 m3/h1000 m3/h

1680 m3/h1500 m3/h

2100 m3/h2000 m3/h

*Refers to bringing outdoor air to near indoor temperature and delivering to a room.

*1 For models: VAM150/250/350/650/800/1000/2000GJVE*2 For models: VAM150/350/500GJVE

A recent trend rapidly gaining popularity is for air treatment to be required as well as air

conditioning. Daikin’s Outdoor-Air Processing Unit can combine fresh air treatment and air

conditioning, supplied from a single system. It adjusts the temperature of air from outdoors

using a fixed discharge temperature control. Along with Outdoor-Air Processing Units, we also

offer Heat Reclaim Ventilator systems. The Heat Reclaim Ventilator VAM-GJ series units in

particular have been praised for their compactness, energy conservation and extensive

operation range of outdoor temperatures. This series provides higher enthalpy efficiency*1, due

to the greatly enhanced performance of the thin film element. Furthermore, improved external

static pressure*2 offers more flexibility for installation. The Heat Reclaim Ventilator VKM-GAM

series units, equipped with a DX-coil and a humidifier, provide further advanced features, such

as temperature adjustment to suit conditions indoors and to prevent cold air from blowing on

people directly during heating operation. The series also realises significant energy savings by

exercising heat recovery.

Daikin’s air treatment systemscreating a higherair quality environment

Componentsof Indoor Air Quality

*Refers to bringing outdoor air to near indoor temperature and delivering to a room.

Ventilation Humidification

Air Processing*

Ventilation Humidification

Air Processing*

Ventilation Humidification

Air Processing*

Ventilation Humidification

Air Processing*

• Easy design and installationThe system is easy to design and install since no addi-tional water systems such as boilers, tanks and gas connections etc are required.

• Inverter controlled units

• Control of air temperature via standard Daikin wired remote control for standard series

177 178

Air

Tre

atm

ent

Equ

ipm

ent

Air Treatment Equipment

LineupFXMQ125MFV1Model Name

Capacity Index

FXMQ200MFV1 FXMQ250MFV1

125 200 250

Navigation Remote Controller(Wired remote controller) (option)

BRC1E63

Air Treatment Equipment

Combine fresh air treatment and air conditioning, supplied from a single system.

Air conditioning and outdoor air processing can be accomplished using a single system.

Fresh air treatment and air conditioning can be achieved with a single system by using heat pump technology — without the usual troublesome air supply and air discharge balance design. Fan coil units for air conditioning and an outdoor-air processing unit can be connected to the same refrigerant line. This results in enhanced design flexibility and significant reduction in total system costs.

The following restrictions must be observed in order to maintain the indoor units connected to the same system.

• When outdoor-air processing units are connected, the total connection capacity index must be 50% to 100% of the capacity index of the outdoor units.

• When outdoor-air processing units and standard indoor units are connected, the total connection capacity index of the outdoor-air processing units must not exceed 30% of the capacity index of the outdoor units.Because connection is possible depending on conditions ever when the capacity index of outdoor-air processing units exceeds 30% of the capacity index of the outdoor units, contact your local distributor.

• Outdoor-air processing units can be used without indoor units.

• The unit introduces outdoor air and adjusts the outdoor air temperature via fixed discharge temperature control, thereby reducing the air conditioning load.

• High-performance filters with dust collection efficiencies (JIS calorimetry) of 90% and 65% are also available as options.

• For the VRV system, a variety of control systems can be deployed, including remote control from distances of up to 500 m.

• The “self-diagnosis function” indicates the occurrence and nature of abnormalities in the system by displaying codes on the remote controller.

• A central control system compatible with the VRV system can be installed.

• With the VRV system, the equipment employs the “super wiring system” so that the wiring linking the indoor and outdoor units can also be utilised for central control.

• Ceiling mounted duct units with three different capacities are available. These can be connected to VRV series outdoor units to meet a variety of different requirements.

• Optional equipment includes long-life filters.

• Compatible with outdoor temperatures from -5°C to 43°C.

Combination with VRV system

* The system can operate with outdoor-air temperatures ranging from -5 to 43°C. Heating performance is somewhat adversely affected when the outdoor-air temperature is 0°C or below.

* When shipped from the factory, the thermostat is set at 18°C for cooling. The set temperature can be varied within the range of 13–25°C during cooling operation, in the local setting mode using the wired remote controller. The temperature, however, is not displayed on the remote controller.

* While in machine protection mode and depending on outdoor air conditions, discharge air temperature may not be at the set temperature.

* The fan stops when operating in defrosting, oil returning and hot start operations. The fan may stop due to mechanical protection control.

* It is not possible to change the discharge air temperature settings from the central control system.

* Do not associate this equipment in areas which standard indoor units are installed, as central control cannot be used with them.

* Group control is not possible between this unit and standard type indoor units. Remote controllers connect to each unit separately.

Notes: 1. The data shown in the graph illustrates the supported operation ranges under the following conditions.

Indoor and Outdoor UnitEffective piping length: 7.5 mHeight differential: 0 m

2. The discharge temperature can be set using the remote controller. However, the actual temperature may not match the temperature setting under some circumstances due to the outdoor-air processing load or mechanical protection controls.

3. The system will not operate in fan mode when the outdoor air temperature is 5°C or below.

Notes: * Linked control of the product and the Heat Reclaim Ventilator is not supported.

* This equipment is intended for the treatment of outdoor air only. It is not to be used for maintaining indoor air temperature, Installing or use with standard indoor units. Be sure to position the air discharge openings of the product in positions where the airflow will not blow on people directly. When outdoor-air processing is in excess, the unit switches to thermo-off mode, and outdoor air flows into the room directly.

* For outdoor ducts, be sure to provide heat insulation to prevent condensation.

* Group control of the product and standard indoor units is not supported. A separate remote controller should be connected to individual unit.

* The system will not operate in fan mode when the outdoor air temperature is 5°C or below.

* If the product is utilised to operate 24 hours a day, maintenance (part replacement, etc.) must be performed periodically.

* Temperature setting and Power Proportional Distribution (PPD) are not possible even if the intelligent Touch Controller or the intelligent Touch Manager is installed.

* The remote controller wired to the outdoor-air processing unit must not be set as the master remote controller. Otherwise, when set to “Auto,” the operation mode will switch according to the outdoor air conditions, regardless of the indoor temperature.

Airflow rate

2,100 m3/h

1,680 m3/h

1,080 m3/h

FXMQ250MFV1

FXMQ200MFV1

FXMQ125MFV1

–5 15 19 (33.5) 43

32

Usage Limitations

Supported Heating

Operation Range

FanOperation

Supported CoolingOperation Range

Outdoor Air T

empera

ture

(°CW

B)

100%

Rela

tive

Hum

idity

90%

Rela

tive

Hum

idity

20% Relative

Humidity

30% Relative Humidity

Central remote controller (option)DCS302CA61

Connection Conditions

Outdoor-air processing unit

Outdoor-Air Processing Unit

Indoor Unit Indoor Unit

AirConditioning

OutdoorAir Supply

VRV Outdoor Units

179 180

Air

Tre

atm

ent

Equ

ipm

ent

Air Treatment Equipment

Air Treatment Equipment

Standard specifications Dimensions

Options

Indoor unit

MODEL

Operation remote controller

FXMQ125MFV1 FXMQ200MFV1 FXMQ250MFV1

BRC1H61W(K) / BRC1E63 / BRC2E61

DCS302CA61

DCS301BA61

DST301BA61

KRP2A61

KRP4AA51

KAFJ371L140 KAF371M280

KAFJ372L140 KAF372M280

KAFJ373L140 KAF373M280

KDJ3705L140 KDJ3705L280

Ope

ratio

n/co

ntro

lFi

lters

Central remote controller

Long-life replacement filter

Colourimetric method 65%

Colourimetric method 90%High-efficiency filter

Filter chamber *1

KRP1B61Adaptor for wiring

KDU30L250VEDrain pump kit

Unified ON/OFF controller

Schedule timer

Wiring adaptor for electrical appendices (1)

Wiring adaptor for electrical appendices (2)

BAF429A20ACPM2.5 with activated carbon filtration unit *2

BAF429A20APM2.5 filtration unit *2

Ceiling Mounted Duct Type

MODEL

Type

Power supply

Cooling capacity *1

Machine weight

Sound level *3

FXMQ125MFV1 FXMQ200MFV1 FXMQ250MFV1

1-phase 220-240 V (also required for indoor units), 50 Hz

0.380

18 28 35

185/225 225/275 205/255

9.5 (flare)

15.9 (flare) 19.1 (brazing) 22.2 (brazing)

PS1B female thread

86 123

42/43 47/48

8 HP and above6 HP and above 10 HP and above

Dimensions (H × W × D) 470 × 744 × 1,100 470 × 1,380 × 1,100

Btu/h 47,800 76,400 95,500

kW 14.0 22.4 28.0

Heating capacity *1Btu/h 30,400 47,400 59,400

kW 8.9 13.9 17.4

mm

Casing Galvanised steel plate

kW

m3/min

Pa

Drain

mm

mm

mm

kg

dB(A)

Motor output

Airflow rate635 988 1,236cfm

Fan

Refrigerantpiping

External static pressure

Liquid

Gas

Connectable outdoor units *4

-5 to 15°C

19 to 43°CCooling

Heating

Cooling

Heating Range of the discharge temperature *5

Operation range (Fan mode operation between 15 and 19°C)

13 to 25°C

18 to 30°C

Power consumption 0.359 0.6380.548kW

220 V/240 V

220 V/240 V

Air filter *2

Indoor unit

Notes: *1. Specifications are based on the following conditions:• Cooling: Outdoor temp. of 33°CDB, 28°CWB (68% RH), and discharge temp. of 18°CDB.• Heating: Outdoor temp. 0°CDB, -2.9°CWB (50% RH), and discharge temp. of 25°CDB.• Equivalent reference piping length: 7.5 m (0 m horizontal)

*2. An intake filter is not supplied, so be sure to install the optional long-life filter or high-efficiency filter. Please mount it in the duct system of the suction side. Select a dust collection efficiency (gravity method) of 50% or more.

*3. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. These values are normally somewhat higher during actual operation as a result of ambient conditions.

*4. It is possible to connect to the outdoor unit if the total capacity of the indoor units is 50% to 100% of the capacity index of the outdoor unit.*5. Local setting mode is not displayed on the remote controller.• This equipment cannot be incorporated into the remote group control of the VRV system.

Inspection hole 600 or more

(All around)

650

or m

ore

(Ser

vice

spa

ce)

1148

1100 or more(Service space)

App

rox.

150

910

C

AB

D

A View

3X10

0=30

0

50

470

Suction side (Note.2)

760

1100

613

2 51 4611Discharge side

30

3

B View

*These diagrams are based on FXMQ200 and FXMQ250MFV1.

Local connection piping size

FXMQ200MFV1

FXMQ125MFV1

Model Gas piping diameter 15.9

19.1 attached piping

Liquid piping diameter 9.5 9.5

FXMQ250MFV1 22.2 attached piping 9.5

Table of dimensions

FXMQ200MFV1

FXMQ125MFV1

Model A B C744 685 5X100=500

1380 1296 11X100=1100

D20- 4.7 hole32- 4.7 hole

FXMQ250MFV1 1380 1296 11X100=1100 32- 4.7 hole

2

1 Liquid pipe connection2 Gas pipe connection3 Drain piping connection4 Electric parts box5 Ground terminal6 Name plate

7 Power supply wiring connection8 Transmission wiring connection9 Hanger bracket

10 Discharge companion flange11 Water supply port12 Attached piping (Note. 1)

360

250

3X10

0=30

033

0

B View

390

30

296

25

630

5X100=500600

20- 7 hole(All around)

8

360

200

250

346

10-M5 hole(All around)

2X200=400

580

630

7

61

A View A View1230

11X100=11001200

245

390

30

60

296

25

360

250

3X10

0=30

033

0

32- 7 hole(All around)

12

8

1004

5X200=1000

123016-M5 hole(All around)

360

200

250

330

B View (For FXMQ250MFV1)

7

5X200=1000

1230

580

360

200

250

330

16-M5 hole(All around)

B View (For FXMQ200MFV1)

7

FXMQ125/200/250MFV1

FXMQ200/250MFV1 FXMQ125MFV1

Notes: 1. The attached piping in the diagram is for FXMQ200MFV1 and FXMQ250MFV1 only. The gas piping connection port ( in the diagram) has a different bore form with FXMQ125MFV1.

2. An air filter is not supplied with this unit. Be sure to mount an air filter in the suction side. [Use a filter with dust collection efficiency of at least 50% (gravimetric method). This is available as an option.]

3. For outdoor ducts, be sure to provide heat insulation to prevent condensation.

Notes: *1. Filter chamber has a suction-type flange. (Main unit does not.)• Dimensions and weight of the equipment may vary depending on the options used.• Some options may not be usable due to the equipment installation conditions, so please confirm prior to ordering.• Some options may not be used in combination.• Operating sound may increase somewhat depending on the options used.

*2. Refer to pages 191 - 192 for details.

181 182

Air

Tre

atm

ent

Equ

ipm

ent

Air Treatment Equipment

Heating and cooling+

+

Heat Recovery

Humidifying

–5 0 5 10 15 20

Dry bulb temperature (°CDB)

25 30 35 40

Rel

ativ

e h

um

idit

y (%

)

20

40

6080100

Effect of full heat exchangeEffect of full heat exchange

Effect of full heat exchangeEffect of cooling

Outdoor air temperature in summer

Indoor temperature during heating

Indoor temperature during cooling

Outdoor air temperature in winter Effect of heatingEffect of heating

Effect of humidificationEffect of humidification

Indoor Unit Indoor Unit

VRV Outdoor Units

Air-Conditioning AirAir

Supply

ReturnAir

Heat Reclaim Ventilator with DX Coil & Humidifier

Outdoor Air

Exhaust Air

Air Treatment Equipment

The heat reclaim ventilator lineup features the DX-coil in response to recently diversifying outdoor air introduction requirements.

A compact unit packed with Daikin’s cutting-edge technologies.

Efficient outdoor air introduction with heat exchanger and cooling/heating operation.

Air conditioning and outdoor air processing can be accomplished using a single system.

Model Name

LineupWith DX Coil & Humidifier Type

Capacity Index 62.5

VKM100GAMV1

50

VKM80GAMV1

31.25

VKM50GAMV1

Model Name

With DX Coil Type

Capacity Index 62.5

VKM100GAV1

50

VKM80GAV1

31.25

VKM50GAV1

The Heat Reclaim Ventilator (VKM series) series introduces fresh outdoor air with minimum heat losses, with a wide variety of features to cater to customer requirements.

Efficient outdoor air introduction is possible

The lineup includes models with a humidifier, in response to diverse customer requirements. (VKM50/80/100GAMV1 only)

Humidifier

Using outdoor air, the temperature can be brought near room temperature with minimal cooling capacity through the use of outdoor air.

Indoor unit with outdoor air treatment

• Integrated system includes ventilation and humidifying operations.

• Ventilation, cooling/heating and humidifying are possible with one remote controller.

Other features

The Heat Reclaim Ventilator features DX-coil that contributes to the prevention of cold airflow colliding people directly during heating operation, due to the after-cool, after-heat operations done beforehand.

DX-coil

High external static pressure means enhanced design flexibility.

High static pressure

HEP Element(Anti-mould)

OA(Fresh air from outdoors)

SA(Supply air to room)

EA(Exhaust air to outdoors)

RA(Return air from room)

Air Supply Fan

Electronics Box(Control box)

Exhaust FanHeat Exchanger Elements

Damper

Damper Motor

Humidifier element30.6°C62% RH

27.4°C63% RH

26°C50% RH

Integrally-formed liner

Indoor

SA

RA

Outdoor

32°C70% RH

Operation of the heat exchanger element

DX-coil (Direct expansion coil)

Heatingby DX-Coil

Heat exchange

To the Outdoor 10.4°C

Outdoor AirFrom the Outdoor 7°C

From the Indoor 20°CReturn Air

To the Indoor 24.5°CSupply Air

HumidificationNatural Evaporating Pan Type Humidifier

Exhaust Air36.5°C16.6°C

Outdoor Indoor

Structure of VKM series

Heating and humidification process

Humidification:5.4kg/h (VKM100GAMV1)

The Outdoor air is heated from 16.6°C to 36.5°C with DX-coil, Natural Evaporating Pan Type Humidifier is passed and humidification capacity is improved.

DX-Coil: Heat Exchanger which heating or cooling the air by VRV outdoor unit’s refrigerant.

The following restrictions must be observed in order to maintain the indoor units connected to the same system.

• When the Heat Reclaim Ventilator VKM series units are connected, the total connection capacity index must be 50% to 130% of the capacity index of the outdoor units.

Connection Conditions

Integrally-formed liner

Temperatureand humidity

RA

SA

Heat Reclaim Ventilator with DX-coil and Humidifier(VKM Series)

183 184

Air

Tre

atm

ent

Equ

ipm

ent

Air Treatment Equipment

200

Air Treatment Equipment

Specifications Dimensions

Options

kg/h

%

%

%

kW

mm

Net

Gross *8kg

Around Unit

OA *9

RA *9

mm

MODEL

Power Supply

Airflow rate

Static pressure Pa

Airflow rate

Static pressure Pa

Heat exchange mode

Bypass mode

Airflow rate

Static pressure Pa

kW

Ultra-high

High dB(A)

Low

Ultra-high

High dB(A)

Low

Ultra-high

High W

Low

Ultra-high

High W

Low

Airflow Rate & Static Pressure *7

Ultra-high

High

Low

Heat exchange mode

Bypass mode

Fan Type

Motor Output

Sound Level *5

(220/230/240 V)

Humidification Capacity *4

Temp. Exchange Efficiency

Ultra-high

High

Low

Enthalpy Exchange Efficiency (Cooling)

Ultra-high

High

Low

Efficiency (Heating)

Ultra-high

High

Low

Casing

Insulating Material

Heat Exchanging System

Heat Exchanger Element

Air Filter

DX-coilCapacity

Cooling *2

Heating *3

Height

Width

Depth

Dimensions

Machine Weight

Unit Ambient Condition

Connection Duct Diameter

Power Consumption

VKM50GAV1 VKM80GAV1 VKM100GAV1R-410A

1-phase, 220–240 V, 50 Hz500160500120440100

750 950140 110750 95090 70640 82070 60

560490420560490420

620560470620560470

670570480670570480

Sirocco Fan0.280 x 2 0.280 x 2 0.280 x 2

37/37.5/3835/35.5/3632/33/34

37/37.5/3835/35.5/3632/33/34

38.5/39/4036/37/37.533/34/35.538.5/39/4036/37/37.533/34/35.5

39/39.5/4037/37.5/38

34/34.5/35.539/39.5/4037/37.5/38

34/34.5/35.52.7 4.0 5.476 78 7476 78 74

77.5 79 76.564 66 626467

6668

6266

67 71 656769

71 6573 69

Galvanised Steel PlateSelf-Extinguishable Urethane Foam

0°C–40°CDB, 80%RH or less-15°C–40°CDB, 80%RH or less0°C–40°CDB, 80%RH or less

387 387 3871,764 1,764 1,764832 1,214 1,214

500180500150440110560490420560490420

0.280 x 238/38.5/3936/36.5/37

33.5/34.5/35.538/38.5/3936/36.5/37

33.5/34.5/35.5

7676

77.5646467676769

75017075012064080

620560470620560470

0.280 x 240/41/41.537.5/38/3934.5/36/3740/41/41.537.5/38/3934.5/36/37

—787879666668717173

95015095010082070670570480670570480

0.280 x 240/40.5/4138/38.5/3935/36/36.540/40.5/4138/38.5/3935/36/36.5

7474

76.5626266656569

2.83.2387

1,764832

20096

2.83.2

4.55.0

5.66.3

4.55.0387

1,7641,214

109—

5.66.3387

1,7641,214

114102107

120129

125134

250 250

Multidirectional Fibrous FleecesSpecially Processed Nonflammable Paper

Air to Air Cross Flow Total Heat (Sensible + Latent Heat) Exchange

m³/h

m³/h

m³/h

Refrigerant

Enthalpy Exchange

VKM50GAMV1 VKM80GAMV1 VKM100GAMV1

Central remote controller

Remote controller

Wiring adaptor for electrical appendices

Unified ON/OFF controllerSchedule timer

For humidifier running ON signal output

Installation box for adaptor PCB

For wiring

Type (VRV indoor unit)

For heater control kit

Silencer

PCB

Ada

ptor

Add

ition

al fu

nctio

nC

ontr

ollin

g de

vice

BRC1H61W(K) / BRC1E63 *1

DCS302CA61

Residential central remote controller DCS303A51 *2

DCS301BA61

DST301BA61

KRP2A61

KRP50-2

BRP4A50

FXFSQ-A

KRP1H98A*2, 3

FXDQ-PDFXDQ-ND

FXLQ-MAFXNQ-MA

FXBQ-P FXBPQ-P

FXZQ-A

KRP1BB101*4

FXFQ-A FXEQ-A

— —

KRP1B61

FXCQ-A

KRP1C67

FXPQ-A

KRP1C96*2, 3

KRP4A98*2, 3

KRP4A97*2, 3

KRP4B93*2, 3

KRP4A987*2, 3, 5

FXDSQ-A FXDQ-SP FXSQ-PA FXMQ-PA

KRP1CA93*3

KRP1D93A*3

— KRP1BA97 ——

FXMQ-P FXUQ-A FXHQ-MA FXHQ-A FXAQ-A FXVQ-N

— KRP1C67KRP1C13A ——

KRP1BB101*4

Centralised controlling device

VKM50/80/100GA(M)V1ItemType

High efficiency filter

Flexible duct (1 m)Flexible duct (2 m)

KDDM24B100

250

K-DGL200C

K-DGL250C

200 250

KAF242J80M KAF242J100MAir filter for replacement KAF241G80M KAF241G100M

K-FDS201E K-FDS251EK-FDS202D K-FDS252E

White

ItemType

Nominal pipe diameter

mm

Nominal pipe diameter

mm

VKM50GA(M)V1 VKM80GA(M)V1 VKM100GA(M)V1

Notes: 1. Cooling and heating capacities are based on the following conditions. Fan is based on High and Ultra-high. When calculating the capacity as indoor units, use the following figures: VKM50GAMV1/GAV1: 3.5 kW, VKM80GAMV1/GAV1: 5.6 kW, VKM100GAMV1/GAV1: 7.0 kW

2. Indoor temperature: 27°CDB, 19°CWB, Outdoor temperature: 35°CDB3. Indoor temperature: 20°CDB, Outdoor temperature: 7°CDB, 6°CWB4. Humidifying capacity is based on the following conditions:

Indoor temperature: 20°CDB, 15°CWB, Outdoor temperature: 7°CDB, 6°CWB5. The operating sound measured at the point 1.5 m below the centre of the unit is

converted to that measured in an anechoic chamber built in accordance with the JIS C 1502 conditions. The actual operating sound varies depending on the surrounding conditions (near running unit’s sound, reflected sound and so on) and is normally higher than this value. For operation in a quiet room, it is required to take measures to lower the sound. For details, refer to the Engineering Data.

6. The noise level at the air discharge port is about 8–11 dB(A) or higher than the unit’s operating sound. For operation in a quiet room, it is required to take measures to lower the sound.

7. Airflow rate can be changed over to Low mode or High mode.8. In case of holding full water in humidifier.9. OA: fresh air from outdoor. RA: return air from room.

10. Specifications, design and information here are subject to change without notice.11. Power consumption and efficiency depend on the above value of airflow rate.

12. Temperature exchange efficiency is the mean value for Cooling and Heating. Efficiency is measured under the following condition: Ratio of rated external static pressure outdoor to indoor is kept constant at 7 to 1.

13. In heating operation, freezing of the outdoor unit’s coil increases. Heating capability decreases and the system goes into defrost operation. During defrost operation, the fans of the unit continues driving (factory setting). The purpose of this is to maintain the amount of ventilation and humidifying.

14. When connecting with a VRV system heat recovery outdoor unit and bringing the RA (exhaust gas intake) of this unit directly in from the ceiling, connect to a BS unit identical to the VRV indoor unit (master unit), and use group-linked operation. (See the Engineering Data for details.)

15. When connecting the indoor unit directly to the duct, always use the same system on the indoor unit as with the outdoor unit, perform group-linked operation, and make the direct duct connection settings from the remote controller. (Mode No. “17 (27)” – First code No. “5” – Second code No. “6”.) Also, do not connect to the outlet side of the indoor unit. Depending on the fan strength and static pressure, the unit might back up.

Feed clean water (city water, tap water or equivalent). Dirty water may clog the valve or cause dirt deposits in the water container, resulting in poor humidifier performance. (Never use any cooling tower water and heating-purpose water.) Also, if the supply water is hard water, use a water softener because of short life.* Life of humidifying element is about 3 years (4,000 hours) under the supply water

conditions of hardness: 150 mg/l. (Life of humidifying element is about 1 year (1,500 hours) under the supply water conditions of hardness: 400 mg/l.)

Annual operating hours: 10 hours/day x 26 days/month x 5 months = 1,300 hours

VKM50/80/100GA(M)V1

4-14 x 40 oval holeHanger bracket

Supply air to room

SA

Return air from room

RA

(For humidifier) *1Maintenance cover

(Natural evaporative type) *1Humidifier

Solenoid valve *1

EA

(Outdoor air)Fresh air from outdoors

Exhaust air to outdoors

OA

Control box

Maintenance Cover

Mo

re t

han

600

hatchInspection

hatchInspection

the air filters, fans (and humidifier)Maintenance space for the heat exchanger elements

140 (In case of 600 inspection hatch)360 (In case of 450 inspection hatch)

High efficiency filter (option)

Liquid pipe connectionAir filters

(PT3/4 male screw)

(ø12.7)

(ø6.4)

connectionGas pipe

Heat exchanger elements

Drain outlet

(ø6.4C1220T)Feed water connection port *1

of the heat exchanger elements.Note *1. VKM50/80/100GAMV1 only.

The high efficiency filter (option) can be attached to the SA surface*( 450 or 600) at the service side of filters and elements.Be sure to provide two inspection hatches.*The specifications are subject to change without notice.*

210

B

42

Supply air fan

160

250

150–

153

C

Damper plate

210

G

K

1688387

235

60

10I

20

153 F

Feed water tank *1

D

130

E

160

144

A

28

102

Direct expansion coil

34

H

J

322

20

1764515

Exhaust air fan

94

Notes: 1. Installation box is necessary for each adaptor marked . 2. Up to 2 adaptors can be fixed for each installation box.3. Only one installation box can be installed for each indoor unit.4. Up to 2 installation boxes can be installed for each indoor unit.5. It is order production.

*1 Necessary when operating a Heat Reclaim Ventilator (VKM) independently. When operating interlocked with other air conditioners, use the remote controllers of the air conditioners.

*2 For residential use only. When connected with a Heat Reclaim Ventilator (VKM), you can only switch the power ON/OFF, it cannot be used with other central control equipment.

VKM50GA(M)V1 VKM80/100GA(M)V1832A 1,214248B 439431C 622164D 183420E 592248F 439878G 1,262137H 89137I 89

196J 246 250K 263

Air suction/Discharge grille

185 186

Air

Tre

atm

ent

Equ

ipm

ent

Air Treatment Equipment

Air Treatment Equipment

The heat reclaim ventilator creates a high-quality environment by interlocking with the air conditioner

Air conditioning load reduced by approximately 31%!

Nighttime free cooling operation*1

Compact Equipment

With a height of only 306 mm, the unit easily fits into limited spaces, such as above ceilings.

Total heat exchange ventilation

This unit recovers heat energy lost through ventilation and curbs room temperature changes caused by ventilation, thereby conserving energy and reducing the load on the air conditioning system.

Auto-ventilation ModeChangeover Switching

Automatically switches the ventilation mode (Total Heat Exchange Mode/Bypass Mode) according to the operating status of the air conditioner.

Pre-cool, Pre-heat Control

Reduces air conditioning load by not operating the Heat Reclaim Ventilator while air is still clean soon after the air conditioner is turned ON.

Enthalpy efficiency drastically improved by employing thin film element! (VAM-GJ model)

• Moisture resistance of the partition sheets is decreased drastically.• There is more space for extra layers in the element, result in increasing of

effective area that supply and exhaust air can be exposed to.

Energy Conservation

Air conditioning load reduced by approximately 31%!

Cold Climate Compatible

Standard operation at temperatures down to -15°C.

This VAM series provides higher enthalpy efficiency *1, due to the greatly enhanced performance of the thin film element. Furthermore, improved external static pressure *2 offers more flexibility for installation. Along with these three outstanding improvements, the nighttime free cooling operation contributes to energy conservation and more comfortable environment.

Nighttime free cooling operation is an energy-conserving function that works at night when air conditioners are off. By ventilating rooms containing office equipment that raises the room temperature, nighttime free cooling operation reduces the cooling load when air conditioners are turned on in the morning. It also alleviates feelings of discomfort in the morning caused by heat accumulated during the night.

Model Names

VAM150GJVEVAM500GJVEVAM1000GJVE

VAM250GJVEVAM650GJVEVAM1500GJVE

VAM350GJVEVAM800GJVEVAM2000GJVE

Daikin air conditionerIndoor unit

LCD remote controllerfor indoor unit

• Operating mode signal • Filter cleaning signal • Failure detection signal

• ON/OFF signal• Cooling/Heating mode signal• Set temperature signal• Ventilation signal

Heat Reclaim Ventilator

OA(Fresh air fromoutdoors)

SA(Supply air to room)

EA(Exhaust air to outdoors) RA

(Return airfrom room)

InterlockingInterlocking

306 mm* For VAM500GJVE -20 -10 0 10 20 30 40 50

50˚CDB-15˚CDB 50˚CDB-15˚CDB

Moisture absorption increased by approx. 10%!

With the thinner film...

23%

Molecule of waterMiscellaneous gas, CO2 molecule, etc.

Sheet structureOutdoor

Exhaust air

SA

Indoor

RA(uncleanindoor air)

Outdoor air (fresh air)

Moisture exchange efficiency is greatly improved by using optimised thinner films and moisture-absorption materials in the element. Furthermore, miscellaneous gas barrier properties are maintained by decreasing the porosity in the moisture-absorption materials.

High-humidity air

Low-humidity air

Precise, thin-filmmaterial

Exhaust air

Supply air

6%

2%

VAM-GJIndividual operation

Normalventilation fan

VAM-GJInterlocked operationwith air conditioner

20%

0%

Air Conditioning Load31%

Exhaustheat

Exhaustheat

The indoor accumulated heat is discharged at night.This reduces the air conditioning load the next day thereby increasing efficiency.

Indoorunit

Indoorunit

Cold air

Generatedheat

Heat is discharged. The load is small so the temperature is rapidly reducedto a comfortable level.*Interlocked operation with an air conditioner

Comfortable!Comfortable!

40 m

Heat Reclaim Ventilator remote controller*BRC301B61 (Option)

* This remote controller is used in case of independent operation of Heat Reclaim Ventilator.

*1 For models: VAM150/250/350/650/800/1000/2000GJVE*2 For models: VAM150/350/500GJVE

Improved Enthalpy Efficiency *1

Higher External Static Pressure *2

Enhanced Energy Saving Functions

40 µm

Thickness ofthe partition sheet

5%*2!

Air conditioning sensibleheat load reduced by

approx.

• The air conditioning load reduction values may vary according to weather and other environmental conditions at the location of the machine's installation.

• The air conditioning load reduction values are based on the following conditions:

Application: Tokyo office buildingBuilding form: 6 floors above ground, 2 floors underground, floor area 2,100 m2

Personnel density: 0.25 person/m2

Ventilation volume: 25 m3/hIndoor air conditioning level: summer 25°C 50% RH, intermediate seasons 24°C

50% RH, winter 22°C 40% RHOperating time: 2745 hours (9 hours per day, approx. 25 days per month)Calculation method: simulation based on "MICRO-HASP/1982" of the Japan

Building Mechanical and Electrical Engineers Association.

• Nighttime free cooling operation only works to cool and if connected to Building Multi or VRV systems.

• Nighttime free cooling operation is set to “off” in the factory settings, so if there is a need to turn on, please contact Daikin dealer.

*1 This function can be operated only when interlocked with air conditioners.

*2 Value is based on the following conditions:• Cooling operation performed from April to October.• Calculated for air conditioning sensible heat load only (latent heat load

not included).

Air conditioning load reduction (%)

Heat Reclaim Ventilator (VAM Series)

Reduced by Approximately

187 188

Air

Tre

atm

ent

Equ

ipm

ent

Air Treatment Equipment

Air Treatment Equipment

CO2 sensor optional kit connection Specifications

The CO2 sensor controls airflow so that it best matches the changes in CO2 level.This prevents energy losses from over-ventilation while maintaining indoor air quality with optional CO2 sensor.

9 10 11 12 13 14 15 16 17 18 19 20 21 Hours

Heat Reclaim Ventilator

Air conditioner

Airflow for ventilation

Energy wastage for ventilation is reduced.Air conditioning load for ventilation is reduced.

CO2 level

Referencevalue

CO

2 le

vel

Airfl

ow f

or v

entil

atio

n

If airflow were constant

Airflow up

Airflow up

Airflow up

7- stage control with different airflow levels

indicates energy savings!

Many people increase CO2 level:

Airflow down

Fewer people decrease CO2 level:

Overtimework

Morningmeetings

Salespersonnel leave

office

Salespersonnel

return

Lunchtime

Airflow down

Airflow down

Example of CO2 sensor operation in an office room:

VAM150GJVE VAM250GJVE VAM350GJVE VAM500GJVE

84/85 79/79

79/79 75/75

79/79 75/75

79/79 74/74

79/79 74/74

75/75 72/72

75/75 72/72

78/78 72/72

78/78 72/72

77/77

77/77

82/82 80/80.5

1-phase, 220-240 V/ 220 V, 50/60 Hz

VAM650GJVE VAM800GJVE VAM1000GJVE VAM1500GJVE

77/77.5 74/74.5 80.5/81 75.5/76

VAM2000GJVE

79/81

MODEL

Temp. Exchange Efficiency(50/60 Hz)

Ultra-High

High

Enthalpy ExchangeEfficiency(50/60 Hz)

Low

%

For Cooling

Ultra-High

High

Low

%

Power Supply

27-28.5/28.5 27-29/29 31.5-33/33 33-35.5/34

26-27.5/27.5 26-27.5/28 30-31.5/30 31.5-34/32

20.5-21.5/21 21-22/21 23-25/23 25-28.5/24

28.5-29.5/29.5 28.5-30.5/30.5 33-34.5/34.5 34.5-36/35.5

27.5-28.5/28.5 27.5-29/29.5 31.5-33/31.5 33-34.5/33.5

22.5-23.5/22

Galvanised steel plate

22.5-23/22.5 24.5-26.5/24.5 25.5-28.5/25.5

150/150 250/250 350/350 500/500

150/150 250/250 350/350 500/500

100/95 155/155 230/230 320/295

278 × 810 × 551 306 × 879 × 800

24 32

Self-extinguishable polyurethane foam

Air to air cross flow total heat (Sensible heat+latent heat) exchange

Specially processed nonflammable paper

Multidirectional fibrous fleeces

Sirocco fan

0.030 × 2 0.090 × 2

100 150 200

-15°C–50°CDB, 80%RH or less

120/154 70/96 169/222 105/150

106/131 54/65 141/145 66/52

56/60 24/20 67/30 32/18

34-36/36 39-40.5/39.5 39.5-41.5/39.5 39.5-41.5/41.5

33-34.5/34 37-39.5/37.5 37.5-39.5/37.5 37.5-39.5/39.5

27.5-29.5/28 35-37.5/34 35-37.5/34.5 35-37.5/36

35-37.5/37.5 40.5-42/41 40.5-42.5/40.5 41-43/42.5

33-35.5/35.5 38.5-40/39 38.5-40.5/38.5 39.5-41/41.5

27.5-30.5/29.5 36-38.5/35.5 36-38.5/35.5 36.5-38/37.5

650/650 800/800 1,000/1,000 1,500/1,500

650/650 800/800 1,000/1,000 1,500/1,500

500/470 700/670 860/840 1,320/1,260

387×1,111×1,214387×1,111×832338×973×832

45 55 67

785×1,619×832 785×1,619×1,214

129

0.140 × 2 0.280 × 2 0.280 × 4

250 350

85/125 133/170 168/192 112/150

53/67 92/85 110/86 73/72

35/38 72/61 85/60 56/50

41.5-43.5/42

39-43/40

36-39/39

43-45.5/44

40.5-45/42

37.5-39.5/41

2,000/2,000

2,000/2,000

1,720/1,580

157

116/140

58/32

45/45

Fan

HeatExchangeMode

Sound Level(50/60 Hz)

BypassMode

Ultra-High

High

Low

Ultra-High

High

Low

dB(A)

dB(A)

Ultra-High

High

Low

mm

kg

Casing

Insulation Material

Heat Exchange System

Heat Exchange Element Material

Air Filter

Type

Dimensions (H × W × D)

Machine Weight

kW

mm

Unit ambient condition

Motor Output

Connection Duct Diameter

Airflow Rate(50/60 Hz)

Ultra-High

High

Low

m3/h

PaExternal Static Pressure(50/60 Hz)

125/134 137/141 200/226 248/270

111/117 120/125 182/211 225/217

57/58 60/59 122/120 128/136

125/134 137/141 200/226 248/270

111/117 120/125 182/211 225/217

57/58 60/59 122/120 128/136

342/398 599/680 635/760 1,145/1,300

300/332 517/597 567/648 991/1,144

196/207 435/483 476/512 835/927

342/398 599/680 635/760 1,145/1,300

300/332 517/597 567/648 991/1,144

196/207 435/483 476/512 835/927

1,289/1,542

1,151/1,315

966/1,039

1,289/1,542

1,151/1,315

966/1,039

HeatExchangeModePower

Consumption (50/60 Hz)

BypassMode

Ultra-High

High

Low

Ultra-High

High

Low

W

W

For Heating

Ultra-High

High

Low

%

Notes: 1. Sound level is measured at 1.5m below the centre of the body. 2. Airflow rate can be changed over to Low mode or High mode.3. Sound level is measured in an anechoic chamber.

Sound level generally becomes greater than this value depending on the operating conditions, reflected sound, and peripheral noise.

4. The sound level at the air discharge port is about 8 dB(A) higher than the unit's sound level.

5. The specifications, designs and information given here are subject to change without notice.

6. Temperature Exchange Efficiency is the mean value between cooling and heating.

7. Efficiency is measured under the following conditions: Ratio of rated external static pressure has been maintained as follows; outdoor side to indoor side = 7 to 1.

8. In conformance with JIS standards (JIS B 8628), operating sound level is based on the value when one unit is operated, with the value converted for an anechoic chamber. This is transmission sound from the main unit, and does not include sound from the discharge grille. Thus it is normal for the sound to be louder than the indicated value when the unit is actually installed.

9. Sound level from the discharge port causes the value to be approximately 8 dB(A) (models with the airflow rate of less than 150 to 500m³/h) to approximately 11 dB(A) (models with the airflow rate of 650m³/h or more) greater than the indicated value. Furthermore, fan rotation and noise from the discharge grille may increase depending on the on-site duct resistance conditions. Please consider noise countermeasures when installing the unit.

10. With large models in particular (1500 and 2000m³/h models), if the supply air (SA) grille is installed near the main unit, the noise of the main unit may be heard from the discharge grille via the duct, and this will result in a marked increase in noise. In such cases, if peripheral effects are included (such as reverberation of the floor and walls, combination with other equipment, and background noise), sound level may be as much as 15 dB(A) higher than the indicated value. When installing a large model, please provide as much separation as possible between the main unit and the discharge grille. If the equipment and discharge grille are near each other, please consider countermeasures such as the following:• Use a sound-muffling box, flexible duct and sound-muffling air supply/discharge

grilles• Decentralised installation of discharge grilles

11. When installing in a location with particularly low background noise such as a classroom, please consider the following measures to avoid transmission sound from the main unit:• Use of ceiling materials with high sound insulating properties (high transmission

loss)• Methods of blocking sound transmission, for example, by adding sound insulating

materials around the bottom of the sound source. Alternatively, consider supplementary methods such as installing the equipment in adifferent location (corridor, etc.)

66/66 63/63 66/66 55/55

66/66 63/63 66/66 55/55

70/70.5 66/66 70/70 59/59.5

61/61 61/61 64/64 61/61

61/61 61/61 64/64 61/61

64/64.5 64/64.5 68.5/69 64/64.5

62/62

62/62

66/67

72/72 71/71 70/70 67/67

72/72 71/71 70/70 67/67

76/76.5 74/74 77/77 74/74.5

67.5/67.5 65/65 70/70 65/65

67.5/67.5 65/65 70/70 65/65

71.5/72 67.5/68 72.5/73 67/67.5

72/72

72/72

76/76

Heat Reclaim Ventilator (VAM Series)

189 190

Air

Tre

atm

ent

Equ

ipm

ent

Air Treatment Equipment

Front FilterHighly Efficient Filter

Air Treatment Equipment

Options PM2.5 filtration unit (Option) for VAM / FXMQ-MF series

Rapid urbanization has increased industrial and automobile emissions, resulting in higher PM2.5 levels. This has become the source of respiratory diseases and poses a serious threat to a long term health issue. As the air quality has worsened, research has shown the harmful effects of PM2.5 on the health of the general public.

Air suction/discharge grille (Obtain locally)

Branch duct(Obtain locally)

SA

SA

RA

EAOA

Duct(Obtain locally)

Flexible duct(Option)

Silencer (Option)

Round hood(Obtain locally)

Thermal insulation material (Obtain locally)

High efficient filter(Option)

BRC301B61

DCS302CA61

DCS303A51*1

DCS301BA61

DST301BA61

KRP2A61

KRP50-2

BRP4A50

KRP50-2A90 (Mounted electric component assy of Heat Reclaim Ventilator)

VAM150 · 250 · 350 · 500 · 650 · 800 · 1000 · 1500 · 2000GJVE

EA

OA

RA

SA

Power supply (Obtain locally)Relay box

Thermostat (Obtain locally)(ON when the temperature is at or below -10°C)

Heat Reclaim Ventilator

Heater(Obtain locally)

BRP4A50

Thermostat (Obtain locally)(OFF when the temperature is at or more than 5°C)

Indoor Outdoor Notes when installing :•Examine fully an installation place and specification for using the electric heater based on the standard and regulation of each country.

•Supply the electric heater and safety production devices such as a relay and a thermostat, etc of which qualities satisfy the standard and regulation of each country at site.

•Use a non-inflammable connecting duct to the electric heater. Be sure to use 2 m or more between the electric heater and the Heat Reclaim Ventilator for safety.

•For the Heat Reclaim Ventilator, use a different power supply from that of the electric heater and install a circuit breaker for each.

VAM150GJVE VAM250GJVE VAM350GJVE VAM500GJVE VAM650GJVE VAM800GJVE VAM1000GJVE VAM1500GJVE VAM2000GJVE

——

KDDM24B50 KDDM24B100 KDDM24B100×2 200 250

KAF242J25M KAF242J50M KAF242J65M KAF242J80MKAF241J65M KAF241J80M

KAF242J100M KAF242J80M×2 KAF242J100M×2KAF241J25M KAF241J50M KAF241J100M KAF241J80M×2 KAF241J100M×2

K-FDS101D K-FDS151E K-FDS201E K-FDS251EK-FDS102D

BAF249A150

BAF249A150C

BAF249A300

BAF249A300C

BAF249A350

BAF249A350C

BAF249A500

BAF249A500C BAF429A20AC

K-FDS152D K-FDS202D K-FDS252E——

YDFA25A1 250

BRYMA65 BRYMA65 BRYMA100BRYMA100

*Refer to pages 191 - 192 for details.

BAF429A20A

Double-layered efficient filtration

Schematic diagram of filter surface

With the capturing effect of static electricity, particles are adsorbed on the filter fabric.

The filter is not blocked and therefore continuous Supply Air is guaranteed.

Long-lasting highly efficient dust collection capacity

The filter mesh is blocked by particles and thus ventilation effect is reduced.

Dust collection capacity decreases remarkably after use for a period of time.

Daikin Electrostatic Dust Collecting Filtration

Dust and particles covering the filter surface

PM2.5 filters are double-layered.1. The front filter effectively removes large particles.2. The PM2.5 filter layer contains a large amount of static electricity to capture particulate matter efficiently.

Electrostatic dust collection filter: more efficient and longer lasting effect

The PM2.5 filter layer contains a large amount of static electricity to capture particulate matter efficiently, including those smaller than the grid mesh.The filter is difficult to be blocked by particles and has good ventilation and long life span.

PCB adaptor for heater control kit (BRP4A50)When the installation of an electric heater is required in a cold region, this adaptor with an internal timer function eliminates the complicated timer connecting work that was necessary with conventional heaters.

Schematic diagram of filter cross-section

Option List

Notes: 1. Installation box is necessary for each adaptor marked . 2. Up to 2 adaptors can be fixed for each installation box.3. Only one installation box can be installed for each indoor unit.4. Up to 2 installation boxes can be installed for each indoor unit.5. It is order production.

*1 For residential use only. When connect with a Heat Reclaim Ventilator (VAM), you can only switch the power ON/OFF. It cannot be used with other central control equipment.

Normal Filtration

Central remote controller

Wiring adaptor for electrical appendices

Unified ON/OFF controllerSchedule timer

For humidifier

Installation box for adaptor PCB

For wiring

Type (VRV indoor unit)

For heater control kit

PCB

Ada

ptorC

ontr

ollin

g de

vice

Residential central remote controller

Heat Reclaim Ventilator remote controller

Installation box for adaptor PCB

Centralised controlling device

ItemType

Silencer

Add

ition

alfu

nctio

n

High efficiency filter

Flexible duct (1 m)

CO2 sensorPM2.5 filtration unit*PM2.5 with activated carbon filtration unit*

Flexible duct (2 m)

Air filter for replacement

ItemType

Silencer Nominal pipe mm

Nominal pipe mm

FXFSQ-A

KRP1H98A*2, 3

FXDQ-PDFXDQ-ND

FXLQ-MAFXNQ-MA

FXBQ-P FXBPQ-P

FXZQ-A

KRP1BB101*4

FXFQ-A FXEQ-A

— —

KRP1B61

FXCQ-A

KRP1C67

FXPQ-A

KRP1C96*2, 3

KRP4A98*2, 3

KRP4A97*2, 3

KRP4B93*2, 3

KRP4A987*2, 3, 5

FXDSQ-A FXDQ-SP FXSQ-PA FXMQ-PA

KRP1CA93*3

KRP1D93A*3

— KRP1BA97 ——

FXMQ-P FXUQ-A FXHQ-MA FXHQ-A FXAQ-A FXVQ-N

— KRP1C67KRP1C13A ——

KRP1BB101*4

191 192

Air

Tre

atm

ent

Equ

ipm

ent

Air Treatment Equipment

Air Treatment Equipment

PM2.5 filtration unit (Option) for VAM / FXMQ-MF series PM2.5 filtration unit

PM2.5 with activated carbon filtration unit

Filtering PM2.5 efficiently for healthier and more comfortable environments

Extra-high performance filter against sulfur oxides and nitrogen oxides

The PM2.5 filtering series heat reclaim ventilator is equipped with an electrostatic dust collection filter for PM2.5 removal. This filter removes 99% or more of 2.5 μm.

Effective Use of Active Carbon Material to Enlarge the Adsorption Area

As an expert in the research and development of filters, DAIKIN has specifically selected active carbon material as the main substance to constitute the filter against sulfur oxides and nitrogen oxides. The material’s usable pore surface is fully exploited, thus extending the filter’s durability.

Notes: Surface area of active carbon: 700 m2/gGiven a newspaper page of 40.6 cm wide by 54.6 cm long, each gram of active carbon has a surface area of 3,000 newspaper pages.

Intelligent Identification, Super-effective Adhesion

The special substance added in the pores of active carbon can exclusively target sulfur oxide and nitrogen oxide gases and stick to them without blocking other unidentified gases. This ensures long durability of the filter.

Note: The figures are based on in-house tests under the following lab conditions: temperature 22 to 25°CDB, humidity 35 to 40% RH, air flow rate 0.2 m/s.

Unidentified Gases

Removal RateRemoval Rate

PM2.5 electrostatic dust collection filter

*Test results by the Heating, Ventilation and Air Conditioning Lab at Tongji University Test environment: temperature 25-26°CDB, humidity 58-60%RH

Dimensions (H × W × D)

Connection Duct Diameter

BAF249A300C BAF249A350C BAF249A500C

220×603×366220×603×366 300×623×366300×623×366

BAF244A300 BAF244A500

BAF244A300C BAF244A500C

150 250 350 500

3 5 5 9

37 35 36 51

34 30 31 42

1 year

1 year

99% or higher

MODEL

Airflow Rate

PM2.5 Filter

ActivatedCarbon Filter

BAF249A150C

Initial Pressure Drop

Filter Lifetime *1

Filtration Efficiency *2

Filter Material No. *3

Initial Pressure Drop

Filter Lifetime

Filter Material No. 3

Total Initial Pressure Drop for PM2.5 with Activated Carbon Filtration Unit

Notes: 1. Annual usage: 400 hrs / month × 12 months = 4,800 hrs.2. 99% or higher removal rate of ultra-fine particles with diameters of 2.5 µm or more.3. Filters come with applicable filtration units with a one-year life. They can be purchased and replaced according to their model numbers.

Initial Pressure Drop

Filter Lifetime *1

Filtration Efficiency *2

Filter Material No. *3

m3/h

mm

mm

Pa

m3/h

mm

mm

Pa

Pa

Pa

Dimensions (H × W × D)

Connection Duct Diameter

Airflow Rate

1 year

99% or higherPM2.5 Filter

MODEL

220×603×366220×603×366 300×623×366300×623×366

BAF244A300 BAF244A500 BAF424A20A

BAF424A20A

BAF424A20AC

150 250 350 500

34 30 31 42

BAF249A300 BAF249A350 BAF249A500BAF249A150

100 150 150 200

470×971×370

2,100

less than 40

BAF429A20A

580×348

470×971×370

2,100

less than 40

580×348 100 150 150 200

BAF429A20AC

less than 10

less than 50

Adhesives

Notes: 1. Annual usage: 400 hrs/month x 12 months = 4,800 hrs2. 99% or higher removal rate of ultra-fine particles with diameters of 2.5 μm or more.3. Filters come with applicable filtration units with a one-year life. They can be purchased and replaced according to their model numbers.

193 194

Co

ntr

ol S

yste

ms

Control Systems

Control Systems

Energy savingSleek and stylish design

• Combines refinement and simplicity• Echoes the distinct blue circle and simplicity of

design • Two attractive colours to match any interior• Compact, measures only 85 x 85 mm

User-friendly interface

• Just three buttons and a large-figure display• Customisable display• Direct access to basic functions (ON/OFF,

Operation mode, Temperature setting, Airflow rate, Airflow direction)

Easy setting via Bluetooth App with smartphone (for Installer / Facility manager)

• Improved setback function by setting the lower temperature limit in cooling and higher temperature in heating mode.

Setpoint range set

• Avoids excessive cooling or heating by limiting the min. and max. set temperature.• Convenient for use at a place where any number of people may operate it.

Setpoint auto reset

• Even if the set temperature is changed, the new set temperature returns to the previous preset value after a preset duration of time.

• Period selectable from 30, 60, 90, or 120 min.

Off timer

• Period can be preset from 30 to 180 minutes in 10-minute increments.

BRC1E63 BRC1F61(Only for FXEQ and FXDSQ series)

Individual control systems for VRV systems

Keep hotel room comfortable

• Easy to create multiple remote control and field settings via App• Prepare a setting in advance at the office and immediately send it to the on-site remote controller• Save and reuse settings

Shorter installation time

Stylish remote controller (Option) Navigation remote controller (Wired remote controller) (Option)

A series of user friendly functions that can be individually selected

BRC1H61W (White)

<App screen image>

BRC1H61K (Black)

A complete redesigned controller focused to enhance user experience

Easy and direct accessto main functions

ON/OFF

Customisable example SIMPLE VIEW

Fan speed Louvre settingMode selection

(cooling, heating, fan only, etc.)

Convenience

Setback (default: OFF)

• Maintains the room temperature in a specific range during unoccupied period by temporarily starting air conditioner that was turned OFF.

Weekly schedule

• 5 actions per day can be scheduled for each day of the week.• The holiday function will disable schedule timer for the days that have been set

as holiday.• 3 independent schedules can be set. (e.g. summer, winter, mid-season)

Auto display off

• Period can be preset from 10, 30, 60 minutes, and OFF. Initial setting is 30 minutes.

Comfort

Individual airflow direction

• Airflow direction can be individually adjusted for each air discharge outlet.

5-step airflow control

• Airflow rate can be selected from 5-step control.

Auto airflow rate

• Airflow rate is automatically controlled.

195 196

Co

ntr

ol S

yste

ms

Control Systems

BRC2E61

Control Systems

Wide variation of remote controllers for VRV indoor units

• A compact signal receiver unit (separate type) to be mounted into a wall or ceiling is included.

• The wireless remote controller is supplied in a set with a signal receiver.

• Signal receiver unit of installed type is contained inside decoration panel or indoor unit.

• Shape of signal receiver unit differs according to the indoor unit.Note: The signal receiver unit shown in the photograph is for mounting inside the decoration panel of

FXF(S)Q series.

• Backlight LCD of new wireless remote controller

Compact size• Measuring only 85 x 85 mm, the new remote controller is

extremely compact and complements any interior design.

Intuitive design• By using pictograms, the user-friendly interface enables convenient

and easy operation.

Simple operationUsing only six buttons, users have direct access to basic functions. This enables them to easily set comfort to their preference.• ON/OFF • Operation mode• Temperature setting • Airflow rate (5-step & Auto)*• Up and down airflow direction (5-step & Swing)*• ON/OFF timer

The wired remote controller supports a wide range of control functions

The indoor unit can be connected by the two remote controllers, for example one in the room and the other one in the control room, which can control the operation of indoor unit freely. (The last command has a priority.) Of course, the group control by two remote controllers is also possible.

The wiring of remote controller can be extended to max. 500 m and it is possible to install the remote controllers for different indoor units in one place.

The operation of Heat Reclaim Ventilator can be controlled by the remote controller of the indoor unit. Of course, the remote controller can display the time to clean the filter.

The system can be expanded to add several controllers, such as BMS, Forced OFF input and etc.

Control by two remote controllers

•Control of Cool/Heat changeover

In all the series of VRV, Cool/Heat changeover in the same refrigerant circuit can be changed by the remote controller of the indoor unit.

Outdoor unit

Equipment related to the central control

One remote controller can control the operation of max.16 indoor units at the same time.

Indoor unit

Remote controller

Remote controller

Remote controller

Remote controller

Forced OFF input

Remote controllerRemote controller Remote

controller

Remote controller

Heat Reclaim Ventilator

•Group control

Signal receiver unit(Separate type)

BRC-C, E series* Wireless remote controller and signal receiver unit are sold as a set. * Refer to page 223 for the name of each model.

* The number of airflow steps and availability of auto airflow rate and swing mode depend on the type of indoor unit.

Navigation remote controller(BRC1E63)

Navigation remote controller(BRC1F61)

Simplified remote controller(BRC2E61)

Wireless remote controller*(Separate type signal receiver unit)

Wireless remote controller*(Installed type signal receiver unit)

*Refer to page 223 for the name of each model.

FXFQFXFSQMODEL FXZQ FXCQ FXHQFXEQ FXDQFXDSQ FXSQ FXUQFXMQ FXAQ FXL(N)Q FXVQ FXPQ FXB(P)Q

Signal receiver unit (Installed type)

BRC-M series

Easy operation with new intuitive design

1 Remote control2 Control for the combined operation3 Expansion of

system control4Pressing the backlight button helps operating in dark rooms.

Individual control systems for VRV systemsSimplified remote controller (Option)

Wireless remote controller (Option)

Stylish remote controller (BRC1H61W / BRC1H61K)

197 198

Co

ntr

ol S

yste

ms

Control Systems

Control Systems

The DIII-NET system provides for:• Close control and monitoring by integrating a wide variety of

air-conditioners in the entire building.• Saves the in-building cabling using non-polar, two-wire cables. Easier wiring

work with tremendously fewer wiring errors.• Additional setups readily up and running. An extendable cabling up to 2 km

in total.• Different control equipment flexibly joined in the system for hierarchical

risk diversification.• Daikin's total heat exchangers and other devices under integral control.

The high speed transmission of DIII-NET enables more advanced control of the VRV system, providing you with enhanced comfort.

Building Control System

(DCM601A51)

ACC Centre

Via internet

Via internet

Air Conditioning Network Service System(There are restrictions in applicable areas and release times, therefore please consult us separately for details.)(Optional Maintenance Service)

BMS(Obtain locally)

Home AutomationMaster Controller

Controllers for Centralised Control

(DCS601C51)

Residential central remote controller

(DCS303A51)

Wiring adaptorfor electrical appendices(KRP2A61/62/51/53)

Unification adaptorfor computerised control(DCS302A52)

Interface for use in BACnet®

(DMS502B51)

Interface for use in LONWORKS®

(DMS504B51)

Home AutomationInterface Adaptor(DTA116A51)

DIII-NET Line

BACnet®/Ethernet or LONWORKS®

Network Communication Line

Contact Signal Line

RS485 Modbus® Line

D -NET(High Speed Multiple

Transmission)

DIII-NET, Daikin’s unique high speed multiple transmission system, links air conditioners and various other building equipment — in accordance with applications, scale and conditions — and transmits vast amounts of information between them.

Interface Adaptor for SkyAir Series(DTA112BA51)

Central Control Adaptor Kit(DTA107A55)

Interface Adaptor for DIII-NET use(KRP928BB2S)

Di unit (DEC101A51)Dio unit (DEC102A51) Building services equipment

• Electrical equipment• Supply water and drainage equipment• Automatic fire alarm• Parking equipment• Lift• Ventilation equipment• Lighting• Crime and fire prevention equipment

VRV

Heat Reclaim Ventilator

SkyAir

Packaged Air-conditioner

Residential Air-conditioner

* No adaptor is required for some indoor units.

Control /Connection Interface

Caution: Limitation may apply to some models and functions. Please contact your local sales office for details. Consultation is necessary before employing this control system. Please contact your local sales office before making a purchase.

Note: BACnet® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). LONWORKS® is a trademark of Echelon Corporation registered in the United States and other countries. Modbus® is a registered trademark of Schneider Electric S.A.

Integrated building monitoring system

VRV

199 200

Co

ntr

ol S

yste

ms

Control Systems

DemandController

(field supply)

Control Systems

One touch selection enables flexible control of equipment in a building.

For energy saving & comfort

intelligent Touch Manager maximises the advantages of VRV features

Building equipment controlVarious types of equipment other than air conditioners, including ventilators, fans, and pumps, can also be controlled.

Lighting controlDALI-compatible LED lighting systems can be controlled and monitored. Lighting control is enhanced through an interlock function with air conditioners and other functions.

Individual air-conditioning controlThe flexible control achieved by the VRV system precisely meets different air conditioning needs in each room (e.g. offices, conference rooms, hotel rooms).

Air-conditioning control for large spacesAir handling units can also be controlled. Large spaces, such as entrance halls and shopping malls, can be easily controlled to ensure comfort.

With Remote controller

With Control System

This heat is killing me.

Turn ON again by remote controller, forgot to turn OFF, and left.

Power consumption saved by control system

8:00 17:00 18:30 8:00 8:00 10:00 18:00

Stop Start

8:00

Working hours(Scheduled)

Turn off as scheduled

Automatically turn OFF to cut wasteful operation Set at 24°C Reset to 24°C

Change to 20°C

Manager room:8:00-20:00

Machine room:24 hours

Admin:8:30-17:00

Common area:9:00-17:00Meeting room:

No schedule

Office:8:00-18:00

Reception:9:00-17:00

16°C

22°C

Very cold.

Oh! Cool.

Set point range 22°C - 28°C

Why?It can not be set below this

Power consumption saved by control system

24ºC

20ºC

Pump Fan

DALI-compatibleDALI-compatible

intelligent Touch Manager is an advanced multi-zone controller that provides the most cost-effective way to control and monitor the Daikin VRV system.The 10.4" LCD touch screen is easy to use with three different screen views to include the floor plan layout view, icon view and list view and menus for system configurations. It is also easy to use with standardized remote Web Access from your PC. It can manage a total of 650 management points consisting of up to 512 Daikin indoor unit groups (up to 1024 indoor units) along with building equipment control / monitoring with Digital Inputs / Output (Di/Dio), Analog Inputs / Output (Ai/Ao) and Pulse input (Pi) optional devices.

DCM601A51

Advanced control systems for VRV systems

Various types of equipment in a building can be controlled by a single controller.

Schedule the operation time for each application. Define the setpoint range that users can change.

Turn the unit OFF if a user didn’t.

External contact demand control function

This function automatically controls outdoor and indoor unit capacity based on contact signals sent from demand controller (field supply) etc. to save power consumption during peak hours.

Reset setpoint regularly.

• You may set 3 levels that can be switched by ON/OFF signal of 3 contacts

• Control settings are pre-set for each level• Outdoor unit: I-demand function for peak power cut-off

Indoor unit: Set temperature shift, Forced thermostat OFF

3 contacts

DCM601A51

D -NET Line

Setting the I-demand function and nighttime quiet operation function is also possible.

201 202

Co

ntr

ol S

yste

ms

Control Systems

Control Systems

Simple wiring (daisy chain) enables management of LED lighting by the intelligent Touch Manager. Various air conditioning and lighting control is enabled through the interlock with occupancy sensors and illuminance sensors.

Switch-on / switch-off and illuminance are controlled based on a schedule to cut wasteful power consumption.

• Up to 5 DALI modules can be connected to a single BACnet® controller.• Up to 64 DALI LED drivers (64 addresses) can be connected to a single DALI module.• 64 DALI addresses can be freely assigned to up to 16 groups using a single DALI module.

(Each group corresponds to a management point of the intelligent Touch Manager.)• Up to 16 scenes can be set to a single DALI module.• Up to 12 sensors (occupancy, illuminance) can be connected to a single DALI module.• DALI BUS simplifies wiring and setting work by daisy chain wiring and automatic address setting.

Air conditioning and lighting for which power consumption is high can be efficiently controlled to promote energy conservation and cost reduction!

DALI BUS

LED light

DALI LED driver

LAN

Sensor(occupancy / illuminance)

DCM009A51(BACnet® Client option)

BACnet®

controller750-831

DALI module753-647

WAGO I/O system

Please contact your local sales office for details.

• Failing to switch off lights is prevented.

• Optimal illuminance reduces energy.

Lighting control achieved by the intelligent Touch Manager

[Operation]• Switch-on/switch-off operation• Illuminance (1–100%) control• Various illuminance patterns can be registered• Registered pattern can be selected from

intelligent Touch Manager

[Monitoring]• Switch-on/switch-off status monitoring• Lighting abnormality monitoring• Illuminance monitoring• DALI occupancy sensor monitoring• DALI illuminance sensor monitoring

Overview of control

OFF OFF

System

Operation durationRoom temperatureExpansion valve opening ratio

Operational informationof individual indoor units

DCM601A51 + DCM002A51*Automatic calculation oftotal power consumption ofindividual indoor units

DCM601A51 + DCM002A51*

DCM601A51

Total power consumption

Pulse

sign

al fro

m

the

kWh

met

er

Tenant A

Tenant A

Tenant B

Tenant BTenant C

Tenant C

kWh meter

HIGH

LOW

MEDIUM

The energy consumption is proportionally calculated for each indoor unit. The data can be used for energy management and calculation of air conditioning usage fees for respective tenants.

Operational information of individual indoor units are monitored, based on distribution of power consumption of outdoor units.

Daikin’s PPD keeps track of powerdistribution for each indoor unit. It performs air conditioning billing calculations quickly and automatically.

Reporting the power consumption of VRV system for each tenant (PPD* Option)

It is easy to output PPD data.PPD data is output in CSV format to a PC or USB memory device and can be freely processed and managed.

Main functions• Register tenants• Set the electricity unit price for 5 time zones• Calculate power consumption and electricity charge

for each tenant• Show aggregation results in the specified period for

each tenant• Output the results (Printout and CSV file)

SVMPC1

Internet / Ethernet

User’s PC

Tenant registration screen VRV electricity bill screen

Invoice Invoice

InvoiceHUB

Setup screen

Users can operate and check the status of VRV system from their smartphones via WiFi.It is not necessary to move where a remote controller is located with this feature.VRV system in other rooms can be operated, and their status can be checked. It is also possible to check if air conditioners in other rooms remain switched on etc., helping achieve energy saving.

The power consumption of VRV controlled by the intelligent Touch Manager can be easily managed for each tenant using a PC. The electricity bill settings facilitate billing work through easy calculation and issuance of VRV electricity bills.

VRV Indoor unit

You can control VRV system fromanywhere through WiFi

LAN cable

SVMPC2

WiFi router Smartphone

VRV Outdoor unit

Just add SVMPC2 to this system

VRV Smartphone Remote ControllerFor buildings

Up to 1024 indoor units can be controlled.

Case 1

Occupancy sensors are used to eliminate both wasteful lighting and air conditioning.When a room is unoccupied, the air conditioning stops and the lighting is switched off.

Case 2

Lighting abnormalities (e.g. burned-out bulbs) can be checked on the intelligent Touch Manager screen.

Case 3

Lighting maintenance becomes easier and quicker.

The layout screen enables quickidentification of specific locations.

With the PPD function, power consumption can be calculated for each indoor unit (Option)

Connection to DALI-compatible lighting control system

Effective service functions offered to tenantsSmartphone will be a remote controller of VRV system (Option)

Air conditioning bills can be issued by one click (PPD* Option)Electricity bills can be easily calculated for each tenant (Option)

*PPD (Power Proportional Distribution) is Daikin’s proprietary calculation method.

*PPD (Power Proportional Distribution) is Daikin’s proprietary calculation method.

Lighting control (Option)In addition to switching lights on and off, advanced lighting control, such as illuminance adjustment, can be achieved

Tenant management

Easy maintenance and energy saving by lighting control

DALI-compatibleDALI-compatible

203 204

Co

ntr

ol S

yste

ms

Control Systems

Control Systems

Connect VRV system to your BMS via BACnet® or LONWORKS®

Compatible with BACnet® and LONWORKS®, the two leading open network communication protocols, Daikin offers interfaces that provide a seamless connection between VRV system and your BMS.

Preventive maintenance

The intelligent Touch Manager can be connected to Daikin’s own Air Conditioning Network Service System for remote monitoring and verification of operation status for VRV system. By its ability to predict malfunctions, this service provides customers with additional peace of mind.

Enhanced convenience with link to the Air Conditioning Network Service System

The intelligent Touch Manager connects seamlessly to Daikin’s 24-hour Air Conditioning Network Service System.

Ease of use and expanded control functions

The user-friendly controller features colours, multilingual function, and icons in the display for ease of understanding. A wide variety of control methods can be accommodated, permitting administrators to monitor and operate the system even when they are away from the controller.

Air Conditioning Network Service System*

ACC centrePersonnel at the centre monitor the occurrence of malfunctions and track their cause via the Internet.Advance malfunction warnings help prevent the sudden occurrence of problems later.

Enable prompt repairs as service engineers know the cause of the problem beforehand.

Trouble

Even malfunctions difficult to identify can be monitored remotely.

Seamless connection between VRV system and BACnet® open network protocol.

Facilitating the network integration of VRV systemand LONWORKS®

BACnet® LONWORKS®

Convenient controllers that offer more freedom to administrators

DCS601C51

RepairAllows dispatching of service engineers without a call from customers.

*Because of restrictions in applicable areas and release times, please consult a Daikin representative separately for details.

Dedicated interfaces make Daikin air conditioners freely compatible with open networks

Monitor Control

VRV Indoor unit

You can control VRV system from anywhere in your house through WiFi

LAN cable

SVMPR2

WiFi router Smartphone

Just add SVMPR2 to this system

For house

Up to 64 indoor units can be controlled.

VRV Smartphone Control System

VRVOutdoor unit

Pump Fan Sensor Keycard switch

Web Access via Internet

Web Access via LAN

Web Access via LAN

100Mbps Ethernet

Fire alarm

Di/Pi port

kWh meter WAGO I/O up to 30 nodes

Up to 512 groups (1024 indoor units)

Max. 64 indoor unit groups

One D -NET systemMax. 64 indoor unit groups (128 indoor units)

Max. 64 indoor unit groups

Max. 64 indoor unit groups

DALI BUS

USB Flash drive

iTM Plus Adaptor

Up to 7 Adaptors

Up to 650 management points

Di/Pi Line

BACnet® / IP

3rd party BACnet® controller

DALI module753-647

Air Handling Unit

Air Conditioning Network Service System

KRP928BB2S

Residential A/C

WAGO I/O system

BACnet® controller750-831

LED light

DALI LED driverSensor(occupancy / illuminance)

DALI BUS

LED light

DALI LED driver

DALI BUS

LED light

DALI LED driverSVMPC1

or

SVMPR2: for controlling 64 units orSVMPC2: for controlling 1024 units

Smartphone

WiFi router

Operation from a smartphone

Tenant billing

Sensor(occupancy / illuminance)

Sensor(occupancy / illuminance)

Smartphone will be a remote controller of VRV system (Option)

Daikin offers a variety of control s ystems

Air conditioning network service system

Notes: 1. BACnet® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).

2. LONWORKS® is a trademark of Echelon Corporation registered in the United States and other countries.

DMS504B51 (Interface for use in LONWORKS®)DMS502B51 (Interface for use in BACnet®)

intelligent Touch Manager system overview

205 206

Co

ntr

ol S

yste

ms

Control Systems

Function

Monitoring

Operation

All site information show on a MSM screen.Connection status, A/C operation status, Error status, Energy consumption etc.

All SVMPC1 function can use on MSM screen.

Control Systems

The VRV system can be operated from the home automation system. VRV tablet and smartphone controller: SVMPC1

Multi site management system by using SVMPC1: MSMPN1

• SVMPC1 is easy to install. Just add DTA116A51 to outdoor unit and connect it to controller.

• Thanks to user-friendly screen, anyone can operate easily.

• Set point range limitation and setback function achieve energy saving and comfortable air-conditioning.

• Daily air-conditioning operation is automatically done by schedule function with annual calendar.

• Quick notification of malfunction by e-mail to support quick maintenance.

The SVMPC1 is easy to install, and enables monitoring and operation of VRV systems via tablets and smartphones. It is optimal for centralized management of VRV systems in small buildings or on individual floors of a building.

VRV Smartphone Control System can be realized by SVMPR1 which is a new product to utilize DTA116A51.

VRV Smartphone Control System

DTA116A51*One adaptor requires for a house

Home AutomationMaster Controller

MonitorOn/Off

Operation mode

Setpoint

Room temperature

Fan direction

Fan volume

Forced off status

Error

Filter sign

Communication status

On/Off status of indoor unitsCooling, Heating, Fan, Dry, Auto (depend on indoor unit capability)Setpoint of indoor units Suction temperature of indoor unitsSwing, Flap direction (depend on indoor unit capability)L, M, H (depend on indoor unit capability)Forced off status of indoor unitsMalfunction, Warning with Error codeFilter sign of indoor unitsCommunication normal/error of indoor units

Control

Retrieve system information

Connected indoor units

Indoor unit capabilities

D -NET address of connected indoor units can be retrieved.Indoor unit capabilities such as operation mode, fan control, setpoint HV can be retrieved.

Up to 16 indoor units can be individually controlled.

VRV Outdoor unit

Up to 2 units can be connected

VRV Indoor unit

Television

Lighting equipment

Electric curtains

Other Home Appliances

Simple installation

RS485 Modbus® Protocol

Wire length is up to 500 m

The VRV outdoor unit and home automation system can be connected simply by using this dedicated adaptor.

Compatible with an existing unit.

Use of Modbus® protocol

On/Off

Operation mode

Setpoint

Fan direction

Fan volume

Filter sign reset

On/Off control of indoor unitsCooling, Heating, Fan, Dry, Auto (depend on indoor unit capability)Cooling/Heating setpointSwing, Stop, Flap direction (depend on indoor unit capability)L, M, H (depend on indoor unit capability)Reset filter sign of indoor units

* Modbus® is a registered trademark of Schneider Electric S.A.

Just addSVMPR1

VRV Outdoor unit

VRV Indoor unit

DTA116A51

Smartphone Monitor ControlWiFi router

LAN cable

SVMPR1

Functions Functions

Specifications

VRV Outdoor unit

VRV Indoor unit

VRV Indoor unit

Up to 64 indoor units can be controlled.

DTA116A51WiFi router

SVMPC1

Internet

VRV Outdoor unit

You can control VRV system from anywhere through WiFi

It is easy to check if units have not been switched off, etc.

* Only admin user can set.

Category Function Detail

Main screen Status monitoring On/Off, Setpoint, Operation mode, Fan step, Flap, Error, Error code, Room TemperatureManual operation On/Off, Setpoint, Operation mode, Fan step, Flap, Scene Control

Automatic control

Setpoint range limitation* Cool setpoint min/max, Heat setpoint min/maxOff timer* Off timer on/off, Off timer duration (5min – 12h, every 5min)Setback operation* Setback setpoint range (Cool: 24-35°C, Heat: 10-20°C)

Schedule* Action registration: Time, On/Off, Setpoint, Operation mode, Fan step, Flap, Off timer on/off, Setback setpointCalendar setting: set by date or day of the week

Language, Password setting, User administration*, Point setting* System setting

Interlock operation depend on equipment statusInterlock

Category Detail

Connectable units

Number of indoor units

Specification

Max 64Number of DTA116A51 1

Connectable device

Max 20Device type iPad, iPhone, Android tablet, Android Phone, Windows Tablet, Windows Phone, Windows PC, MacWeb browser Firefox, Chrome, Safari

SiteHeadquarters

WiFi router

MSMPN1

Internet

VRV Outdoor unit

VRV Indoor unit

DTA116A51

WiFi router

SVMPC1

Site

The MSMPN1 enables monitoring and operation of all VRV system connected via SVMPC1 on each site.

Home automation interface adaptor

Image to use home automation interface adaptor DTA116A51

Simple and easy smart control

*A separate power supply for Home Automation Interface Adaptor is necessary. It may not be installed inside some outdoor unit models.

You can control VRV from anywhere in your house through WiFi

Number of Tablet/Smartphone

207 208

Prec

isio

n P

ipin

g M

eth

od

Precision Piping Method

Pipes can be joined easily & quickly without brazing and any special tools.

Innovative problem solving for VRV refrigerant piping installation

Precision Piping Method

Non-brazing / Save installation time A smarter way to connect refrigerant piping

Easy piping installation that anyone

can do

Reliabilityimprovement

Faster work with simplified installation

using basic tools

Installationimprovement

Flameless installationwithout welding for safe,

worry-free work

Safetyimprovement

Packaged Refnet Headers

HEADER PACK

Fire free connection for piping

Daikin Gas Tight JointSafe connection without a flame (in brazing work)

Time saver with easy fitting installation

Less labour intensive

Daikin Gas Tight Joint

Time Saver using Quick Flare Nut Connection

Space Saving with Compact Design

Connects up to 4 and 6 indoor units

HEADER PACK

209 210

Prec

isio

n P

ipin

g M

eth

od

Precision Piping Method

Easy piping connection / Easy installation

Easy installation

No need for brazing tools or installation skills Quick piping anyone can do with two spanners

Excellent sealing mechanism

Precision Piping Method

Suitable luxions residence Evolutionally advanced feature

580Suspension bolt Pitch

W

D

BHF6ARHP6Z,BHF8/10/16RHP6Z

Connect by Daikin Gas Tight Joint or flare

Quick flare nut connection

Easy installation

517

W

D

Suspension bolt Pitch

• Installation time saving 1/3 of conventional• Easy to install No brazing work• Safety No fire in the building• Space saving Low silhouette only 14 cm height

HEADER PACK Lineup

Refnet joint ×5

HEADER PACK

DAIKIN Gas Tight Joint HEADER PACK

1 2 3 4 5 6Brazing

IDU

1 2 3 4 5IDU6

Flare

4 port type 6 port type

Dimensions (Top view)BHF6RHP6Z

HP(VRV System)

Indoor unit totalcapacity indexModel name

Outdoor unit side

Liquid / Gas (mm)

9.5 / 15.9

(Flare)

9.5 / 15.9

(Flare)

9.5 / 19.1

(Daikin Gas Tight Joint)

9.5 / 22.2

(Daikin Gas Tight Joint)

12.7 / 28.6

(Daikin Gas Tight Joint)

Indoor unit side (Flare)

Port

Dimension (mm)

H D WLiquid / Gas (mm)

Large ×1

Small ×3

Large ×2

Small ×4

Large ×3

Small ×3

Large ×3

Small ×3

Large ×3

Small ×3

9.5 / 15.9

6.4 / 12.7

9.5 / 15.9

6.4 / 12.7

9.5 / 15.9

6.4 / 12.7

9.5 / 15.9

6.4 / 12.7

9.5 / 15.9

6.4 / 12.7

150

150

200

290

420

135

135

135

135

135

4

6

6

6

6

143

143

143

143

143

559

623

623

623

623

BHF6RHP6Z

BHF6ARHP6Z

BHF8RHP6Z

BHF10RHP6Z

BHF16RHP6Z

Reduction of connection points by elimination of refnet joints

6

6

6 · 8

10

12 · 14 · 16

• Connectable up to 4 & 6 IDU

Susp

ensi

on

bo

lt P

itch

178

Susp

ensi

on

bo

lt P

itch

178

Matching for various piping sizes

Asymmetry joints (Connecting different size pipes)

Standard joints (Connecting the same pipes)

6.4

9.5

19.0

22.0

46.2

51.4

106

139

L

AF1

ND

1

ND

2

AF2

Weight / PC(g)

Dimension(mm)

ND AF LFigure

Figure MODEL

BDGTA1209

BDGTA1512

BDGTA2219

BDGTA2825

Weight / PC(g)

Dimension(mm)

ND1 ND2 AF1 L

BDGTA06

BDGTA09

MODEL

BDGTA12

BDGTA15

BDGTA19

BDGTA22

BDGTA28

BDGTA34

BDGTA41

12.7

15.9

19.1

22.2

28.6

34.9

41.3

23.8

29.7

35.0

38.0

45.0

51.1

58.3

82.3

82.8

85.5

93.5

99.5

101.5

103.5

170

236

327

401

546

686

881

12.7

15.9

22.2

28.6

24.0

29.7

38.0

45.0

AF2

22.0

23.8

35.0

41.8

62.4

83.2

87.4

94.4

158

220

362

510

Double sealingProof pressure 4.3 MPa (-45°C through +130°C)

Leverage methodThe pull-out resistance is more than 4 times (17.2 MPa)

Authorised standards

ISO 14903

Certification of international standards Proof of safety and reliability

SGBP (Singapore Green Building Council)

• Certificate Number SGBP 2019-2405• Green Mark compatible products

9.5

12.7

19.1

25.4

L

AF

ND

L

AF

ND

HEADER PACK Daikin Gas Tight JointSimple & Quick!

211 212

Op

tio

n L

ist

Option List

Option List

Outdoor units

Distributivepiping

REFNET joint

REFNET headerKHRP26M22H, KHRP26M33H

(Max. 4 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T

RXQ18AM(W)RXQ20AM(W)RXQ22AM(W)

RXQ18A(W)RXQ20A(W)

RXQ6A(W)RXQ8A(W)RXQ10A(W)

Type

Item

No.

1

Outdoor unit multi connection piping kit2

KHRP26M22H, KHRP26M33H, KHRP26M72H(Max. 4 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72T— BHFP22P100

Distributivepiping

REFNET joint

REFNET headerKHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H

(Max. 4 branch) (Max. 8 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73T

Type

Item

No.

1

BHFP22P100 BHFP22P151Outdoor unit multi connection piping kit3

KHRP26M73TP, KHRP26M73HPPipe size reducer2

RXQ12A(W)RXQ14A(W)RXQ16A(W)

RXQ26AM(W)RXQ28AM(W)RXQ30AM(W)

RXQ18AM(W)RXQ20AM(W)RXQ22AM(W)RXQ24AM(W)

RXQ6A(W)RXQ8A(W)RXQ10A(W)RXQ12A(W)

Type

Item

No.

DIII-NET expander adaptor1 DTA109A51External control adaptor2 DTA104A61Home Automation Interface Adaptor3 DTA116A51Option plate for control adaptor4 BKS26A*1— BKS26A*1—

DIII-NET expander adaptor1 DTA109A51External control adaptor2 DTA104A61Home Automation Interface Adaptor3 DTA116A51Option plate for control adaptor4 BKS26A *1

Type

Item

No.

RXQ14A(W)RXQ16A(W)RXQ18A(W)RXQ20A(W)

Option PCB

RXQ24AM(W)RXQ26AM(W)RXQ28AM(W)RXQ30AM(W)RXQ32AM(W)

RXQ34AM(W)RXQ36AM(W)RXQ38AM(W)RXQ40AM(W)

RXQ42AM(W)RXQ44AM(W)RXQ46AM(W)RXQ48AM(W)RXQ50AM(W)

RXQ52AM(W)RXQ54AM(W)RXQ56AM(W)RXQ58AM(W)RXQ60AM(W)

RXQ32AM(W)RXQ34AM(W)RXQ36AM(W)RXQ38AM(W)

RXQ40AM(W)RXQ42AM(W)RXQ44AM(W)RXQ46AM(W)

RXQ48AM(W)RXQ50AM(W)RXQ52AM(W)RXQ54AM(W)

RXQ56AM(W)RXQ58AM(W)RXQ60AM(W)

Note: *1. This plate is necessary for each adaptor marked .

RXUQ22AM(W)RXUQ24AM(W)RXUQ26AM(W)RXUQ28AM(W)RXUQ30AM(W)

RXUQ18AM(W)RXUQ20AM(W)

RXUQ6A(W)RXUQ8A(W)

Type

Item

No.

DIII-NET expander adaptor1 DTA109A51External control adaptor2 DTA104A61Home Automation Interface Adaptor3 DTA116A51Option plate for control adaptor4 BKS26A*1— BKS26A*1—

DIII-NET expander adaptor1 DTA109A51External control adaptor2 DTA104A61Home Automation Interface Adaptor3 DTA116A51Option plate for control adaptor4 BKS26A*1

Type

Item

No.

RXUQ10A(W)RXUQ12A(W)RXUQ14A(W)RXUQ16A(W)RXUQ18A(W)RXUQ20A(W)

Option PCB

RXUQ32AM(W)RXUQ34AM(W)RXUQ36AM(W)RXUQ38AM(W)RXUQ40AM(W)

RXUQ42AM(W)RXUQ44AM(W)RXUQ46AM(W)RXUQ48AM(W)RXUQ50AM(W)

RXUQ52AM(W)RXUQ54AM(W)RXUQ56AM(W)RXUQ58AM(W)RXUQ60AM(W)

Note: *1. This plate is necessary for each adaptor marked .

Distributivepiping

REFNET joint

REFNET headerKHRP26M22H, KHRP26M33H

(Max. 4 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T

RXUQ12AM(W)RXUQ14AM(W)RXUQ16AM(W)RXUQ18AM(W)RXUQ20AM(W)

RXUQ18AM1(W)RXUQ20AM1(W)RXUQ22AM(W)

RXUQ12A(W)RXUQ14A(W)RXUQ16A(W)RXUQ18A(W)RXUQ20A(W)

RXUQ6A(W)RXUQ8A(W)RXUQ10A(W)

Type

Item

No.

1

Outdoor unit multi connection piping kit2

KHRP26M22H, KHRP26M33H, KHRP26M72H(Max. 4 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72T— BHFP22P100

Distributivepiping

REFNET joint

REFNET headerKHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H

(Max. 4 branch) (Max. 8 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73T

Type

Item

No.

1

BHFP22P100 BHFP22P151Outdoor unit multi connection piping kit3

KHRP26M73TP, KHRP26M73HPPipe size reducer2

RXUQ24AM(W)RXUQ26AM(W)RXUQ28AM(W)RXUQ30AM(W)RXUQ32AM(W)

RXUQ34AM(W)RXUQ36AM(W)RXUQ38AM(W)RXUQ40AM(W)

RXUQ42AM(W)RXUQ44AM(W)RXUQ46AM(W)RXUQ48AM(W)RXUQ50AM(W)

RXUQ52AM(W)RXUQ54AM(W)RXUQ56AM(W)RXUQ58AM(W)RXUQ60AM(W)

RXUQ12AM(W)RXUQ14AM(W)RXUQ16AM(W)RXUQ18AM1(W)RXUQ20AM1(W)

REFNET joint(KHRP26A22/33/72/73T)

REFNET joint(KHRP26A22/33/72/73T)

213 214

Op

tio

n L

ist

Option List

Note: *1. This plate is necessary for each adaptor marked .

Option List

Outdoor units

KHRP26M22H, KHRP26M33H, KHRP26M72H(Max. 4 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72T—

RXYQ12AHRXYQ14AHRXYQ16AH

RXYQ18AHRXYQ20AHRXYQ22AH

KHRP26M73TP, KHRP26M73HP

RXYQ24AH

KHRP26M22H, KHRP26M33H,(Max. 4 branch) (Max. 8 branch)KHRP26M72H, KHRP26M73H

(Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73T

RXYQ26AHRXYQ28AHRXYQ30AHRXYQ32AHRXYQ34AH

RXYQ36AHRXYQ38AHRXYQ40AHRXYQ42AHRXYQ44AH

Distributivepiping

REFNET joint

REFNET header

Type

Item

No.

1

Pipe size reducer2

BHFP22P100 BHFP22P151KRC19-26ACool/Heat selector4

Outdoor unit multi connection piping kit3

RXYQ38AHRXYQ40AHRXYQ42AHRXYQ44AH

Type

Item

No.

DIII-NET expander adaptor1 DTA109A51External control adaptor2 DTA104A61Home Automation Interface Adaptor3 DTA116A51Option plate for control adaptor4 — BKS26A*1

DIII-NET expand adaptor1 DTA109A51External control adaptor2 DTA104A61

3 DTA116A51Option plate for control adaptor4 BKS26A*1BKS26A*1 ——

Type

Item

No.

RXYQ36AHRXYQ28AHRXYQ30AHRXYQ32AHRXYQ34AH

RXYQ12AHRXYQ14AHRXYQ16AHRXYQ18AH

RXYQ20AHRXYQ22AHRXYQ24AHRXYQ26AH

Option PCB

Option PCB

Distributivepiping

REFNET joint

REFNET headerKHRP26M22H, KHRP26M33H

(Max. 4 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T

RXYQ22ARXYQ6ARXYQ8ARXYQ10A

Type

ItemNo.

1

KRC19-26A

KHRP26M22H, KHRP26M33H, KHRP26M72H(Max. 4 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72TOutdoor unit multi connection piping kit2 — BHFP22P100

RXYQ16ARXYQ18A

RXYQ20ARXYQ12ARXYQ14A

Cool/Heat selector3

KHRP26M73TP, KHRP26M73HPKHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73T

KHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H(Max. 4 branch) (Max. 8 branch) (Max. 8 branch) (Max. 8 branch)Distributive

piping

REFNET joint

REFNET header

Type

Item

No.

1

Pipe size reducer2

BHFP22P100 BHFP22P151Outdoor unit multi connection piping kit3

KRC19-26ACool/Heat selector4

RXYQ24A

RXYQ26ARXYQ28ARXYQ30ARXYQ32A

RXYQ34ARXYQ36ARXYQ38ARXYQ40A

RXYQ42ARXYQ44ARXYQ46ARXYQ48A

RXYQ50ARXYQ52ARXYQ54ARXYQ56A

RXYQ58ARXYQ60A

RXYQ14ARXYQ16ARXYQ18ARXYQ20A

RXYQ6ARXYQ8ARXYQ10ARXYQ12A

RXYQ22ARXYQ24A

KHRP26M22H, KHRP26M33H,(Max. 4 branch) (Max. 8 branch)

KHRP26M72H (Max. 8 branch)

Home Automation Interface Adaptor

RXYQ26ARXYQ28ARXYQ30ARXYQ32ARXYQ34ARXYQ36A

RXYQ38ARXYQ40ARXYQ42ARXYQ44ARXYQ46ARXYQ48A

RXYQ50ARXYQ52ARXYQ54ARXYQ56ARXYQ58ARXYQ60A

Note: *1. This plate is necessary for each adaptor marked .

Option PCB

No.Item

Type

DIII-NET expander adaptor 1 DTA109A51

External control adaptor 2 DTA104A61

Home Automation Interface Adaptor 3 DTA116A51

BKS26B BKS26COption plate for control adaptor 4

RSU(Y)Q4A RSU(Y)Q5A RSU(Y)Q6A RSU(Y)Q7A

Air direction adjustment grille

ItemNo.

5

Type

REFNET joint 3 KHRP26A22T KHRP26A22T, KHRP26A33T

Drain plug 4 BKP082A41

Header pack1 BHF6RHP6Z, BHF6ARHP6Z, BHF8RHP6Z

REFNET header 2 KHRP26M22H (Max. 4 branch), KHRP26M33H (Max. 8 branch)

KPW082A41

RSU(Y)Q4A RSU(Y)Q5A RSU(Y)Q6A RSU(Y)Q7A

2 KRC19-26ACool/Heat selector

1 Header pack

No. TypeItem

2-1 Fixing box

3

4

5 Central drain plug

6 Fixture for preventing overturning

7 Wire fixture for preventing overturning

BHF6RHP6Z, BHF6ARHP6Z, BHF8RHP6Z

REFNET header

K-KYZP15C

KJB111A —

KKPJ5G280

KKTP5B112

KHRP26A22T, KHRP26A33T

KHRP26M22H (Max. 4 branch), KHRP26M33H (Max. 8 branch)

KHRP26A22T

K-KYZP15C

KKPJ5G280

KKTP5B112

KHRP26A22T, KHRP26A33T

KHRP26M22H (Max. 4 branch), KHRP26M33H (Max. 8 branch)

KHRP26A22T

REFNET joint

RXYMQ4A RXYMQ5B RXYMQ6B RXYMQ8A RXYMQ9A

Heat Pump

1 Header pack

No. TypeItem

4 Central drain plug

5 Fixture for preventing overturning

6 Wire fixture for preventing overturning

BHF6RHP6Z, BHF6ARHP6Z, BHF8RHP6Z

2 REFNET header

3 REFNET joint

RXMQ4A RXMQ5B RXMQ6B RXMQ8A RXMQ9A

Cooling Only

215 216

Op

tio

n L

ist

Option List

Option List

Outdoor units

Distributive piping

REFNET joint

REFNET header

RQ(Y)Q6T(E)RQ(Y)Q8T(E)RQ(Y)Q10T(E)

RQ(Y)Q12T(E)RQ(Y)Q14T(E)RQ(Y)Q16T(E)

KHRP26M22H, KHRP26M33H (Max. 4 branch), (Max. 8 branch)

KHRP26M22H, KHRP26M33H, KHRP26M72H(Max. 4 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72TKHRP26A22T, KHRP26A33T

KHRP26M22H, KHRP26M33H (Max. 4 branch) (Max. 8 branch),

KHRP26M72H (Max. 8 branch)

KHRP26M22H, KHRP26M33H, (Max. 4 branch) (Max. 8 branch)KHRP26M72H, KHRP26M73H

(Max. 8 branch) (Max. 8 branch)Distributive piping

REFNET joint

REFNET header

RQ(Y)Q18TN(E)RQ(Y)Q20TN(E)RQ(Y)Q22TN(E)

RQ(Y)Q24TN(E)RQ(Y)Q26TN(E)RQ(Y)Q28TN(E)

RQ(Y)Q30TN(E)RQ(Y)Q32TN(E)

Outdoor unit multi connection piping kit

Pipe size reducer

KHRP26A22T, KHRP26A33T, KHRP26A72T KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73T

— KHRP26M73TP, KHRP26M73HP

BHFP22P100

KHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H(Max. 4 branch) (Max. 8 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73TKHRP26M73TP, KHRP26M73HP

BHFP22P151

Distributive piping

REFNET joint

REFNET header

RQ(Y)Q34TN(E)RQ(Y)Q36TN(E)

RQ(Y)Q38TN(E)RQ(Y)Q40TN(E)

RQ(Y)Q42TN(E)RQ(Y)Q44TN(E)

RQ(Y)Q46TN(E)RQ(Y)Q48TN(E)

Outdoor unit multi connection piping kit

Pipe size reducer

Distributive piping REFNET header

REFNET joint

RQ(Y)Q18T(E)RQ(Y)Q20T(E)

KHRP26M22H, KHRP26M33H, KHRP26M72H(Max.4 branch) (Max.8 branch) (Max.8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72T

Distributive piping

RQ(Y)Q30TS(E)RQ(Y)Q32TS(E)RQ(Y)Q34TS(E)

RQ(Y)Q36TS(E)RQ(Y)Q38TS(E)RQ(Y)Q40TS(E)

RQ(Y)Q42TS(E)RQ(Y)Q44TS(E)

RQ(Y)Q46TS(E)RQ(Y)Q48TS(E)

KHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H(Max.4 branch) (Max.8 branch) (Max.8 branch) (Max.8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73TKHRP26M73TP, KHRP26M73HP

BHFP22P100 BHFP22P151Pipe size reducer

Outdoor unit connection piping kit

REFNET header

REFNET joint

Type

Item

No.

1

Type

Item

No.

Type

ItemNo.

1

Type

Item

No.

1

Type

ItemNo.

1

2

1

3

2

3

2

3

RWEYQ6TRWEYQ8TRWEYQ10TRWEYQ12T

RWEYQ14TRWEYQ16TRWEYQ18TRWEYQ20TRWEYQ22TRWEYQ24T

RWEYQ26TRWEYQ28TRWEYQ30TRWEYQ32TRWEYQ34TRWEYQ36T

Distributive piping

KHRP25M33H (Max. 8 branch), KHRP26M22H (Max. 4 branch), KHRP26M33H (Max. 8 branch)

KHRP25M33H (Max. 8 branch),KHRP25M72H (Max. 8 branch),KHRP26M22H (Max. 4 branch),KHRP26M33H (Max. 8 branch),KHRP26M72H (Max. 8 branch)

KHRP25M33H (Max. 8 branch), KHRP25M72H (Max. 8 branch), KHRP25M73H (Max. 8 branch), KHRP26M22H (Max. 4 branch), KHRP26M33H (Max. 8 branch), KHRP26M72H (Max. 8 branch), KHRP26M73H (Max. 8 branch)

KHRP25A22T, KHRP25A33T, KHRP26A22T, KHRP26A33T

KHRP25A22T, KHRP25A33T, KHRP25A72T, KHRP26A22T, KHRP26A33T, KHRP26A72T

KHRP25A22T,KHRP25A33T, KHRP25A72T, KHRP25A73T, KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73T

Strainer kit BWU26A15, BWU26A20DTA104A62External control adaptor

Outside unit multi connection piping kit — BHFP22MA84

Item

Type

BHFP22MA563

4

2

1

No.

REFNET joint

REFNET header

KRC19-26A (Applies to RQYQ only)2 Cool / Heat selector

KRC19-26A (Applies to RQYQ only)2 Cool / Heat selector

KRC19-26A (Applies to RQYQ only)4 Cool / Heat selector

KRC19-26A (Applies to RQYQ only)4 Cool / Heat selector

KRC19-26A (Applies to RQYQ only)4 Cool / Heat selector

Distributive piping REFNET header

REFNET joint

RWHQ12THRWHQ14THRWHQ16TH

KHRP26M22H, KHRP26M33H, KHRP26M72H (Max. 4 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72TBHFP22P100

BRCM82BRCS82

Outdoor unit multi connection piping kit

Hot water controller box

Hot water remote controller

Distributive piping REFNET header

REFNET joint

KHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H(Max. 4 branch) (Max. 8 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73TKHRP26M73TP, KHRP26M73HP

BHFP22P151BRCM82BRCS82

Pipe size reducer

Outdoor unit multi connection piping kit

Hot water controller box

Hot water remote controller

Distributive piping REFNET header

REFNET joint

RWHQ24THRWHQ26THRWHQ28TH

RWHQ30THRWHQ32THRWHQ34TH

RWHQ18THRWHQ20THRWHQ22TH

KHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H(Max. 4 branch) (Max. 8 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73TKHRP26A22T,KHRP26A33T, KHRP26A72T

KHRP26M73TP, KHRP26M73HP—BHFP22P151

BRCM82BRCS82

Pipe size reducer

Outdoor unit multi connection piping kit

Hot water controller box

Hot water remote controller

KHRP26M22H, KHRP26M33H,(Max. 4 branch) (Max. 8 branch)

KHRP26M72H(Max. 8 branch)

Type

Item

No.

1

2

3

4

Type

Item

No.

1

2

3

4

5

Type

ItemNo.

1

2

3

4

5

RWHQ48THRWHQ50TH

RWHQ36THRWHQ38TH

RWHQ44THRWHQ46TH

RWHQ40THRWHQ42TH

217 218

Op

tio

n L

ist

Option List

Option List

Outdoor units

Distributivepiping

REFNET header

REFNET joint

RWHQ18TRWHQ20T

KHRP26M22H, KHRP26M33H, KHRP26M72H(Max. 4 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72TBRCM82BRCS82

Hot water controller boxHot water remote controller

Distributivepiping

REFNET header

REFNET joint

KHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H(Max. 4 branch) (Max. 8 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73TKHRP26M73TP, KHRP26M73HP

BHFP22P151BRCM82BRCS82

Pipe size reducerOutdoor unit multi connection piping kitHot water controller boxHot water remote controller

RWHQ42TSRWHQ44TSRWHQ46TS

RWHQ48TSRWHQ50TS

RWHQ36TSRWHQ38TSRWHQ40TS

RWHQ22TSRWHQ30TSRWHQ32TSRWHQ34TS

RWHQ24TSRWHQ26TSRWHQ28TS

Distributivepiping

REFNET header

REFNET joint KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73T

KHRP26M73TP, KHRP26M73HP—BHFP22P100

BRCM82BRCS82

Pipe size reducerOutdoor unit multi connection piping kitHot water controller boxHot water remote controller

KHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H(Max. 4 branch) (Max. 8 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T,KHRP26A72T

KHRP26M22H, KHRP26M33H,(Max. 4 branch) (Max. 8 branch)

KHRP26M72H(Max. 8 branch)

Distributivepiping

REFNET header

REFNET joint

RWHQ58TNRWHQ60TN

RWHQ34TNRWHQ36TNRWHQ38TNRWHQ40TN

RWHQ50TNRWHQ52TNRWHQ54TNRWHQ56TN

RWHQ42TNRWHQ44TNRWHQ46TNRWHQ48TN

KHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H(Max. 4 branch) (Max. 8 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73TKHRP26M73TP, KHRP26M73HP

BHFP22P151BRCM82BRCS82

Pipe size reducerOutdoor unit multi connection piping kitHot water controller boxHot water remote controller

RWHQ30TNRWHQ32TN

RWHQ24TNRWHQ26TNRWHQ28TN

RWHQ18TNRWHQ20TNRWHQ22TN

KHRP26A22T, KHRP26A33T,KHRP26A72T, KHRP26A73T

Distributivepiping

REFNET header

REFNET joint

KHRP26M73TP, KHRP26M73HP

KHRP26A22T, KHRP26A33T, KHRP26A72T

BHFP22P100BRCM82BRCS82

Pipe size reducerOutdoor unit multi connection piping kitHot water controller boxHot water remote controller

Distributivepiping

REFNET header

REFNET joint

RWHQ12TRWHQ14TRWHQ16T

RWHQ6TRWHQ8TRWHQ10T

KHRP26A22T, KHRP26A33T, KHRP26A72TKHRP26A22T, KHRP26A33T

KHRP26M22H, KHRP26M33H,(Max. 4 branch) (Max. 8 branch)KHRP26M72H, KHRP26M73H

(Max. 8 branch) (Max. 8 branch)

KHRP26M22H, KHRP26M33H,(Max. 4 branch) (Max. 8 branch)

KHRP26M72H(Max. 8 branch)

BRCM82BRCS82

Hot water controller boxHot water remote controller

KHRP26M22H, KHRP26M33H, KHRP26M72H(Max. 4 branch) (Max. 8 branch) (Max. 8 branch)

KHRP26M22H, KHRP26M33H(Max. 4 branch) (Max. 8 branch)

Type

ItemNo.

1

23

TypeItem

No.

1

23

Type

ItemNo.

1

2345

Type

ItemNo.

1

2345

Type

ItemNo.

1

2345

Type

Item

No.

1

2345

Standard Type

Space Saving Type

VRV indoor units

Round Flow Cassette with Sensing Type

Round Flow Cassette Type

Decoration panel

Panel spacer

Filter chamber

Replacement long-life filter

Replacement long-life filter (Auto grille panel)

Ultra long-life filter unit (Including filter chamber) 9

Replacement ultra long-life filter 9, 10

Branch duct chamber 4

Insulation kit for high humidity 9, 11

Sealing material of air discharge outlet 4

Fresh air intake kit

For usage of 3-, 4-way flow

For usage of 2-way flow

High-efficiency filter unit 9

(Including filter chamber)

(Colorimetric method 65%)

(Colorimetric method 90%)

Replacement high-efficiency filter 9, 10(Colorimetric method 65%)

(Colorimetric method 90%)

Direct installation type 7

Without T-duct jointChambertype 5,6 With T-duct joint

Fresh white

Designer panel 1 Fresh white

Auto grille panel 2, 3 Fresh white

Black1

3

7

8

9

10

11

12

13

2

4

5

6

KDBH551C160KDBH552C160

KDDP55C160 (Components: KDDP55C160-1, KDDP55C160-2) 8

KDDP55C160K (Components: KDDP55C160-1, KDDP55C160K2) 8

KDDP55X160A

KDB55J160F

KDDFP55C160KAF5511D160KAF5512D160KAF555D160KAF550D160

KAF556D80 KAF556D160KAF557D80 KAF557D160KAF552D80 KAF552D160KAF553D80 KAF553D160

KDJP55C80 KDJP55C160KDTP55K80A KDTP55K160A

FXFQ50AFXFQ63AFXFQ80A

FXFQ25AFXFQ32AFXFQ40A

FXFQ100AFXFQ125AFXFQ140A

BYCQ125EAPF *BYCQ125EASF *

BYCQ125EAF *BYCQ125EAK *

Standard panel

No.Type

Item

Fresh white

Black

Decoration panel

Panel spacer

Filter chamber

Replacement long-life filter

Replacement long-life filter (Auto grille panel)

Ultra long-life filter unit (Including filter chamber) 9

Replacement ultra long-life filter 9, 10

Branch duct chamber 4

Insulation kit for high humidity 9, 11

Sealing material of air discharge outlet 4

Fresh air intake kit

For usage of 3-, 4-way flow

For usage of 2-way flow

High-efficiency filter unit 9

(Including filter chamber)

(Colorimetric method 65%)

(Colorimetric method 90%)

Replacement high-efficiency filter 9, 10(Colorimetric method 65%)

(Colorimetric method 90%)

Direct installation type 7

Without T-duct jointChambertype 5,6 With T-duct joint

KDBH551C160KDBH552C160

KDDP55C160 (Components: KDDP55C160-1, KDDP55C160-2) 8

KDDP55C160K (Components: KDDP55C160-1, KDDP55C160K2) 8

KDDP55X160A

BYCQ125EEFBYCQ125EEK

KDB55J160F

KDDFP55C160KAF5511D160KAF5512D160KAF555D160KAF550D160

KAF556D80 KAF556D160KAF557D80 KAF557D160KAF552D80 KAF552D160KAF553D80 KAF553D160

KDJP55C80 KDJP55C160KDTP55K80A KDTP55K160A

FXFSQ50AFXFSQ63AFXFSQ80A

FXFSQ25AFXFSQ32AFXFSQ40A

FXFSQ100AFXFSQ125AFXFSQ140A

Standard panel with sensing

Fresh white

Designer panel 1 Fresh white

Auto grille panel 2, 3 Fresh white

Black

BYCQ125EAPF *BYCQ125EASF *

1

3

7

8

9

10

11

12

13

2

4

5

6

BYCQ125EAF *BYCQ125EAK *

Standard panel

No.Type

Item

Notes: 1. When installing designer panel, body height (ceiling required dimension) is 42 mm higher than standard panel. Designer panel cannot operate 2 and 3 way flow.2. A dedicated wireless remote controller (BRC16A2) for the auto grille panel is included for lowering and raising the suction grille.3. When installing auto grille panel, body height (ceiling required dimension) is 55 mm higher than standard panel.4. Circulation airflow is not available with this option.5. When installing a fresh air intake kit (chamber type), two air outlet corners are closed.6. It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating sound and may also influence temperature sensing.7. The volume of fresh air for direct installation type is approximately 1% of the indoor unit airflow. The chamber type is recommended when more fresh air is necessary.8. Please order using the names of both components instead of set name.9. This option cannot be installed to designer panel and auto grille panel.

10. Filter chamber is required.11. Please use in case temperature/humidity inside ceiling may get over 30˚C, 80% RH.*These panels do not contain the sensing function.

219 220

Op

tio

n L

ist

Option List

Ultra long-life filter

Filter chamber(Can be used with high-efficiency filter)

High-efficiency filter

Filter chamber(Can be used with ultra long-life filter)

Top panel insulation(1)

Top panel insulation(2)

Top panel insulation(3)

•Insulation for decoration panel•Side panel insulation •Suspension bracket insulation

Outside

Option List

VRV indoor unitsOptions of Round Flow Cassette with Sensing & Round Flow Cassette

Ultra long-life filter unit

Even in dusty environments where the air conditioning is constantly operating, the ultra long-life filter only has to be cleaned once a year.

Branch duct chamber

This chamber lets you connect a round flexible duct to the air discharge opening at any time after the original installation.

Sealing material of air discharge outlet

By using this option, 2-way, 3-way, or 4-way flow can be selected.

Panel spacer

Use when only minimal space is available between drop ceilings and ceiling slabs.

High-efficiency filter unit

Available in two types: 65% and 90% colorimetry.

Insulation kit for high humidity

Please use if you think the temperature and humidity inside the ceiling exceeds 30°C and RH 80%, respectively.

Fresh air intake kit 1, 2

Using this kit, a duct can be connected to take in outdoor air. There are two chamber types that have intake in two places: with T-duct joint and without T-duct joint.

The units can be installed in the following different ways:

Note: Some ceiling constructions may hinder installation. Contact your Daikin Dealer before installing your unit.

40mm

Panel spacer

Dusty area: annual filter change*For dust concentration of 0.3 mg/m3 (Requires separately sold Air purifier.)1 year (Approx. 5,000 hr): About 15 hr/day x 28 day/month x 12 month/year

Ordinary store or office: filter change every 4 years*For dust concentration of 0.15 mg/m3 4 years (Approx. 10,000 hr): About 8 hr/day x 25 day/month x 12 month/years x 4 years

Direct installation type 6

Notes: 1. Use of options will increase operating sound.2. Connecting ducts, fan, insect nets, fire dampers, air filters, and other

parts should, as required, be obtained locally. 3. When a local-obtained fan is used, an interlock with air conditioner is

necessary. Optional PCB (BRP11B62) is required for interlocking.4. When installing a fresh air intake kit (chamber type), two air outlet

corners are closed.5. It is recommended that the volume of outdoor air introduced through

the kit is limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating sound and may also influence temperature sensing.

6. The volume of fresh air for direct installation type is approximately 1% of the indoor unit airflow.The chamber type is recommended when more fresh air is necessary.

Options required for specific operating environments

Single Flow Cassette Type

Decoration panel

FXEQ20AFXEQ25A

FXEQ32AFXEQ40AItem

Type FXEQ50AFXEQ63A

BYEP40AW1 BYEP63AW1

No.

1

Slim Duct (Standard) TypeFXDQ25PD FXDQ32PDFXDQ20PD

KDT25N32 KDT25N50 KDT25N63Insulation kit for high humidity

TypeItem FXDQ63NDFXDQ50NDFXDQ40NDNo.

1

Middle Static Pressure Duct Type

FXSQ40PAFXSQ50PAFXSQ63PAFXSQ80PA

FXSQ20PAFXSQ25PAFXSQ32PA

FXSQ100PAFXSQ125PA FXSQ140PA

KAF633C80 KAF633C160KDDF63B160B KDDFP63B80 KDDFP63B160

KAF631C80 KAF631C160KTBJ25K80F

KAF633C56 KDDFP63B56KAF631C56KTBJ25K56F

KAF633C36KAF632C80 KAF632C160KAF632C56KAF632C36

KDDFP63B36KAF631C36KTBJ25K36F KTBJ25K160F

KDAP25A71A KDAP25A140A KDAP25A56A KDAP25A36A KDBD63A160

KDAP25A160A *2

Item

Type

KAF632B160BKAF633B160B

KAF631B160B

No.

1

2

3456

Notes: *1. If installing high efficiency filter and long-life filter to the unit, filter chamber is required.*2. This option is a set of KDAP25A140A and KDBHP37A160.

High efficiency filter *1

Filter chamber (for rear suction) *1

Long-life filter *1

Service panel (Fresh white)

Air discharge adaptorShield plate for side plate

65%90%

Flexible duct BFD37B40 BFD37B50 BFD37B631

3D Airflow Duct with Sensing TypeTypeItemNo. FXDSQ20A FXDSQ25A FXDSQ32A FXDSQ40A FXDSQ50A FXDSQ63A

Double Flow Cassette Type

Compact Multi Flow Cassette Type

Note: *1. If installing high efficiency filter, filter chamber is required.

Note: 1. Option relay wire harness adaptor (BER01A1) is necessary when installing decoration panel (BYFQ60B3W1).

FXCQ20A FXCQ25A FXCQ32A FXCQ40A FXCQ50A FXCQ63A FXCQ80A FXCQ125ADecoration panel

High efficiency filter *1

Filter chamber for bottom suction

BYBCQ40CFKAF532C50KAF533C50KDDFP53B50

Long life replacement filter KAF531C50

BYBCQ63CFKAF532C80KAF533C80

KDDFP53B80KAF531C80

BYBCQ125CFKAF532C160KAF533C160

KDDFP53B160KAF531C160

TypeItemNo.

1

2

34

90 %65 %

KDDP55X160A

Chamber type (with T-duct joint) 3, 4, 5

KDDP55C160K

Chamber type (without T-duct joint) 3, 4, 5

KDDP55C160 Flexible duct(obtained locally)

T-duct joint(obtained locally)

Intake duct(obtained locally)(duct length: 4 m max.)

Connection chamberSuction chamber

Flexible duct

T-duct joint

Intake duct(obtained locally)(duct length: 4 m max.)

Connection chamber

Duct flange (with insulation material)

Suction chamber

Intake duct(obtained locally)

FXMQ100PAFXMQ125PAFXMQ140PA

Middle-High Static Pressure Duct Type

FXMQ40PAFXMQ50PAFXMQ63PAFXMQ80PA

FXMQ20PAFXMQ25PAFXMQ32PA

KAF372B80 KAF372B160KAF373B80 KAF373B160

KDDF37AA80 KDDF37AA160KAF371B80 KAF371B160KAF375B80

KAF372B56KAF373B56

KDDF37AA56KAF371B56KAF375B56

KAF372AA36–––– KAF375B160

KTBJ25K80F KTBJ25K160FKTBJ25K56FKTBJ25K36FKDAJ25K71AKDAJ25K56AKDAJ25K36A KDAJ25K140A

Item

65%90%

TypeNo.

2

345

6

7

High efficiency filter

Filter chamberLong life replacement filterLong life filter chamber kit

Service panel (Fresh white)

Air discharge adaptor

1 Drain pump kit –

TypeItem

BYFQ60CAWBRYQ60AAWBYFQ60B3W1

BER01A1KDBH44BA60KAF441C60

KDDQ44XA60

Grid ceiling panelSensor kit for grid ceiling panelDecoration panel *1

Relay wire harness adaptor for decoration panel *1

Sealing material of air discharge outlet for decoration panelReplacement long life filterFresh air intake kit

1-11-22-12-22-334

No. FXZQ20A FXZQ25A FXZQ32A FXZQ40A FXZQ50A

221 222

Op

tio

n L

ist

Option List

Option ListVRV indoor units

TypeItemNo.

BDU510A250VMBDT520A250

BAFM503A250BAFH504A250

BAFL501A250BAFL502A250

BDD500A250

FXMQ200P FXMQ250P

FXUQ71A FXUQ100A

High Static Pressure Duct Type

65%90%

5

3

Drain pump kit

6 Insulation kit for high humidity

High efficiency filter

4 Filter chamber (long life filter, high efficiency filter)

1 8mm pre-filter2 30mm long life replacement filter

Ceiling Suspended Type

FXHQ32MA1 Drain pump kit2 Replacement long-life filter

KDU50N60VEKAFJ501D56

3 L-type piping kit (for upward direction) KHFP5M63

FXHQ125A

KDUP50P160KAF501B160KHFP5N160

FXHQ140AFXHQ63MA

KDU50N125VEKAFJ501D80

KHFP5M160

FXHQ100MA

KAFJ501D112

No. TypeItem

Wall Mounted Type

FXAQ25AFXAQ20A

K-KDU572EVE

FXAQ32A FXAQ40A FXAQ50A FXAQ63ANo. TypeItem1 Drain pump kit

BEV15D BEV30D2 External EV kit (for heating operation)*1

Concealed Floor Standing Type

FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA

KAF361L28 KAF361L45 KAF361L71

No. TypeItem1 Long life replacement filter

Floor Standing Type

FXLQ20MA FXLQ25MA FXLQ32MA FXLQ40MA FXLQ50MA FXLQ63MA

KAF361L28 KAF361L45 KAF361L71

No. TypeItem1 Long life replacement filter

FXVQ125N FXVQ200N FXVQ250N FXVQ500NFXVQ400NTypeItem

TypeItem

Replacement long life filterUltra long-life filter

Front suction filter chamber for highefficiency filter

Plenum chamber *4

Pulley for plenum chamber *4

Fresh air intake kitRear suction kitDischarge grille for plenum side

Wood baseVibration isolating frame

KAF261M140

KD-9A140KDGF-9A140KAF-91B140KAF-92B140KAF-93B140KDDF-9A140

KPCJ140AKPP8JA

KDFJ905B140

KKWJ9A140K-ABSG1406A

KAF261M224—

KD-9A200KDGF-9A200KAF-91B200KAF-92B200KAF-93B200KDDF-9A200

KPC5JKPP9JA

KAF261M280

KD-9A280KDGF-9A280KAF-91B280KAF-92B280KAF-93B280KDDF-9A280

KPC8JKPP10JA

KAF261N450KAFSJ9A400KD-9A400

KDGF-9A400KAF-91B400KAF-92B400KAF-93B400KDDF-9A400

KPCJ400A

KAF261N560KAFSJ9A560KD-9A560

KDGF-9A560KAF-91B560KAF-92B560KAF-93B560KDDF-9A560

KPC15JA

KDFJ905B200

KWF1G5PK-ABSG1407A

KDFJ905B280

KWF1G8PK-ABSG1408A

KDFJ905B400

KKWJ9A400K-ABSG1409A

KDFJ905B560

KWF1G15K-ABSG1410A

Front suction base flange

Suction grille

Filter chamber *1, 2

Replacement long-life filter *1, 2, 3

Dis

char

ge a

nd S

uctio

n

No.

KDFJ906A560KD106D10

KD101A10

KD101A20

Notes: *1. When ordering a filter chamber for high efficiency filter (65%), please order with all the respective parts.*2. When ordering a filter chamber for high efficiency filter (90%), please order with all the respective parts.*3. When replacing with a new filter, please order the replacement filters with the corresponding filter model name.*4. Use the plenum chamber and pulley for plenum chamber in combination.

FXBQ40P FXBQ50P FXBQ63P FXBPQ63PTypeItem

Outlet unitFilter

Panel

Outside air intake duct flange

BAFH82A50BYB82A50CBYB82A50W

—BAFH82A63

BYB82A63CBYB82A63W

KDFJ82A80

BAF82A63

BYB82A63CPBYB82A63WP

HEPA filterCeiling intake typeFloor-level intake type

Clean Room Air Conditioner

Floor Standing Duct Type

Spot Air Conditioner

KCD-250D1 *1, 2

KCD-250D2 *1, 2

KCD-350D1 *1

KCD-350D2 *1

CHC250 *1, 2

CHC350 *1

CHH250CHH350 *1

KDF87A28KDG87A28 + KPW87A28

KAF87A28GKAF87A28

KKSH87B28 *4 (KKSH87B28-1 + KKSH87B28-2)KKSS87B28

KWM87A28 *1, 3

Extension duct

Duct fixing band

Duct suspending band

Air discharge adaptorAirflow direction adjustment grille (Manual adjustment)Oil-mist filterLong life replacement filterInstallation standLifting lugAuxiliary drain pan

FXPQ25A

250

250

350

350250350

Notes: *1. It is order production.*2. Air discharge adaptor (KDF87A28) is used.*3. Lifting lug (KKSS87B28) is available in combination.*4. Wired remote controller is available.

123456789101112131415

No.

1

2

3

456789

10

No.

12345

Filter chamber for high efficiency filter *1, 2

Replacement high efficiency filter

65% *1, 3

90% *2, 3

4-Way Flow Ceiling Suspended Type

Sealing material of air discharge outletDecoration panel for air dischargeReplacement long-life filter

KDBHP49B140KDBTP49B140KAF5511D160

TypeItemNo.

123

Note :*1. This option is only effective for reducing operation sound during heating operation. Therefore it is ineffective when connected to cooling only outdoor units.

Residential indoor units with connection to BP units

BP Units for Connection to Residential Indoor UnitsBPMKS967A2

1 REFNET joint KHRP26A22T

BPMKS967A3No. TypeItem

Wall Mounted Type

Slim Ceiling Concealed Type

FDKS35EACDXS35EA

FDKS25EACDXS25EA

1 Insulation kit for high humidity KDT25N32

FDKS25CAFDXS25C

FDKS35CAFDXS35C

FDKS50CFDXS50C

FDKS60CFDXS60C

No.Type

ItemKDT25N50 KDT25N63

FTKS25DFTXS25E

FTKS35DFTXS35E

FTXS20D FTKS50FFTXS50F

FTKS60FFTXS60F

FTKS71FFTXS71F

FTKS50B

1 Titanium apatite deodorising filter*1 KAF970A46 KAF971B422 Dust collection filter (PM 2.5) with frame BAFP046A42 –3 Dust collection filter (PM 2.5) without frame BAFP046A41 –

No.Type

Item

FTKJ35NFTXJ35N

FTKJ25NFTXJ25N

FTKJ50NFTXJ50N

Note: *1. Filter is a standard accessory. It should be replaced approximately 3 years.

Note: A single BP unit does not require a REFNET joint. 2 BP units require only 1 REFNET joint, and 3 BP units require only 2 REFNET joints.

4 Fresh air intake kit KDDQ50A140—

Precision Piping MethodHEADER PACK

Daikin Gas Tight Joint1

No.

1

No.

6

HEADER PACK BHF6RHP6Z

6

BHF6ARHP6Z

6–8

BHF8RHP6Z

10

BHF10RHP6Z

12–16

BHF16RHP6Z

HPItem

Connecting the same pipes

Daikin Gas Tight JointBDGTA06, BDGTA09, BDGTA12BDGTA15, BDGTA19, BDGTA22BDGTA28, BDGTA34, BDGTA41

Connecting different size pipes

BDGTA1209, BDGTA1512BDGTA2219, BDGTA2825

TypeItem

223 224

Op

tio

n L

ist

Option List

Example:

Interlocking operation of the indoor unit and ventilation fan that takes in fresh air.

VRV outdoor unit

Ventilation Fan Adaptor

IndoorUnit

Air Conditioning + Ventilation

Notes: 1. Installation box for adaptor must be obtained locally. 2. For residential use only. Cannot be used with other

centralised control equipment.

3. No adaptor is required for some indoor units.4. Because the maximum transmission length varies according to actual installation conditions and

diameter of wiring used, please confirm by a dedicated simulator.5. Installation box is necessary for adaptor BRP114A61. Please refer to option list for each indoor unit.

Option List

Control systems

Operation control system optional accessories

No. Item Model No. Function

1

intelligent TouchController

Basic Hardware intelligent TouchController DCS601C51 • Air-Conditioning management system that can be controlled by a

compact all-in-one unit. 1-1 Hardware

OptionSoftware

DIII-NET plus adaptor

Web software

DCS601A52

DCS004A51

• Additional 64 groups (10 outdoor units) is possible.

1-3

1-2

Electrical box with earth terminal (4 blocks) KJB411A • Wall embedded switch box.2

intelligent TouchManager

Basic Hardware intelligent Touch Manager DCM601A51 • Air-conditioning management system that can be controlled by touch screen.

2-1

Option

Hardware iTM plus adaptor DCM601A52 • Additional 64 groups (10 outdoor units) is possible.Max. 7 iTM plus adaptors can be connected to intelligent Touch Manager.

• VRV system that is connected to intelligent Touch Controller can be operated from the user's PC via a web page.

2-2

2-3 Software

Hardware

iTM powerproportionaldistribution

DCM002A51• Power consumption of indoor units are calculated based on operation

status of the indoor unit and outdoor unit power consumption measured by kWh metre.

2-42-52-62-72-82-9

iTM energynavigator DCM008A51 • Building energy consumption is visualised.

Wasted air-conditioning energy can be found out.• BACnet® equipment can be managed by intelligent Touch Manager.• Interface for intelligent Touch Manager by HTTP• VRV Smartphone Control System for residence• VRV Smartphone Remote Controller for building• Tenant Billing System with PPD• VRV Smartphone Control System for residence with DTA116A51.

BACnet® client DCM009A51DCM007A51

SVMPR2SVMPC2

SVMPS1 *5

SVMPR1

SVMPC12-10

2-112-122-13

VRV Tablet and Smartphone Controller

VRV Smartphone Control System

3

Communicationinterface

Interface for use in BACnet® *2 DMS502B51• Interface unit to allow communications between VRV and BMS.

Operation and monitoring of air-conditioning systems through BACnet® communication.

3-1 Optional DIII board DAM411B51• Expansion kit, installed on DMS502B51, to provide 2 more DIII-NET

communication ports. Not usable independently.

3-2 Optional Di board DAM412B51 • Expansion kit, installed on DMS502B51, to provide 16 more wattmeterpulse input points. Not usable independently.

4 Interface for use in LONWORKS® *3

5 Home Automation Interface Adaptor

DMS504B51• Interface unit to allow communications between VRV and BMS.

Operation and monitoring of air-conditioning systems through LONWORKS®

communication.

DTA116A51 • Use of the Modbus® protocol enables the connection of the VRV system with a variety of home automation systems from other manufacturers. *6

6Contact/analogue signal

Unification adaptor for computerisedcontrol DCS302A52 • Interface between the central monitoring board and central control units.

HTTP Interface

SVM series *1

Notes: *1. HTTP interface (DCM007A51) is also required.*2. BACnet® is a registered trademark of American Society of Heating, Refrigerating and

Air-Conditioning Engineers (ASHRAE).*3. LonWorks® is a trademark of Echelon Corporation registered in the United States and

other countries.

*4. Installation box for adaptor must be obtained locally.*5. PPD option (DCM002A51) for iTM is also required.*6. Modbus® is a registered trademark of Schneider Electric S.A.

System configurationNo. Item Model No. Function

1 Residential central remote controller DCS303A51 *2• Up to 16 groups of indoor units (128 units) can be easily controlled using the

large LCD panel. ON/OFF, temperature settings and scheduling can be controlled individually for indoor units.

2345

Interface adaptor for residential indoor unitsInterface adaptor for SkyAir-seriesCentral control adaptor kit For UAT(Y)-K(A),FD-KWiring adaptor for other air-conditioner

7-1 Multi tenant unit for Indoor (24 V free type)

7-2 Multi tenant unit for Outdoor (24 V free type)

7-3 Multi tenant unit Booster (24 V free type)

KRP928BB2S • Adaptors required to connect products other than those of the VRV System to the high-speed DIII-NET communication system adopted for the VRV System.* To use any of the above optional controllers, an appropriate adaptor must be

installed on the product unit to be controlled.DTA103A51DTA107A55

DTA112BA51 *3

6 DIII-NET expander adaptor DTA109A51• Up to 1024 units can be centrally controlled in 64 different groups.• Wiring restrictions (max. length: 1,000m, total wiring length: 2,000m, max.

number of branches: 16) apply to each adaptor.

Building management system

6-1 External control adaptor DTA104A61 • Demand control of individual or multiple systems.• Low noise option for individual or multiple systems.

• Use in multi tenant buildings where one tenant shuts off the breaker of the indoor unit.• Max. length from outdoor unit to last indoor unit per 1 outdoor adaptor is 200 m.• 8 indoor units can be connected per 1 outdoor adaptor.

• Use when extending transmission length with the multi tenant option.• Can add Max. 3 booster units to 1 system.• Total transmission length is Max. 800 m.• Total connectable indoor units is Max. 32 units.

6-2 Mounting plate BKS26A

BRP114A61 *4, 5

BRP114A62 *4

BRP114A63 *4

• When installing DTA109A51, DTA104A61 into outdoor units of 10 HP (VRV X) / 14 HP (VRV A/H) or larger.

MSMPN1DEC101A51DEC102A51

• MSM can control all VRV units via SVM system on multi site.• 8 pairs based on a pair of ON/OFF input and abnormality input.• 4 pairs based on a pair of ON/OFF input and abnormality input.

Multi Site Management System by using SVMPC1Di unitDio unit

• VRV Tablet and Smartphone Controller for small size building or residence with DTA116A51.

5-1 Mounting plate BKS26A • When installing DTA116A51 into outdoor units of 10 HP (VRV X) / 14 HP (VRV A/H) or larger.

For VRV indoor unit use

For residential indoor unit useType

Item

No.

KRP413BB1S

Wireless typeRemote controller

Remote controller loss prevention chain

Wiring adaptor for time clock/remote controller *2

(Normal open pulse contact/normal open contact)

1

2

3

— *1

KRP928BB2SInterface adaptor for DIII-NET use4

FDKS-EA, C(A)CDXS-EAFDXS-C

FTKJ-NFTXJ-N

FTKS-D, B, FFTXS-D, E, F

Remote sensorBRCS01A-1(4)(5)(6)

New Design

BRP11B61 BRP11B62

Adaptor for wiring (operation status output)By installing it in the indoor unit with a simple wire connection, this adaptor takes out the operating signals for the indoor unit fan and the compressor and enables the interlocking of equipment such as the ventilation fan.

Notes: 1. A wireless remote controller is a standard accessory.2. Time clock and other devices should be obtained locally.

Stylish remote controller

No.

1

2

3

4

5-1

5-2

6-1

6-2

7

8

9

10

No.

1

2

3

4

5-1

5-2

6-1

6-2

7

8

9

10

11

12

KKF917A4 KKF910A4 KKF917A4

Notes: 1. Installation box is necessary for each adaptor marked .2. Up to 2 adaptors can be fixed for each installation box.3. Only one installation box can be installed for each indoor unit.4. Up to 2 installation boxes can be installed for each indoor unit.5. Some functions can be set only via the wired remote controller

BRC1E63 or BRC1F61. They cannot be set via other remote controllers. Please refer to each indoor unit and remote controller page for function details.

6. Since the control panel is equipped as standard, use the option of BRC1E63 for 2 remote control system.

7. When using BRC1H61W(K), BRC1E63 or BRC2E61, be sure to remove the control panel and since BRC1H61W(K), BRC1E63 and BRC2E61 cannot be stored inside the indoor unit, please place it separately.

8. Remove the group control adaptor which is a standard equipment before mounting KRP2A62, KRP2A61 and DTA104A62. KRP2A62, KRP2A61 and DTA104A62 cannot be mounted to the same indoor unit at the same time.

9. When KRP4AA51 is used, operation by two remote controllers is not available.10. It is order production.

Navigation remote controller

Simplified remote controller

C/O

H/P

Adaptor for wiring (operation status output)

Adaptor for wiring

Wiring adaptor for electrical appendices (1)Wiring adaptor for electrical appendices (2)Remote sensor (for indoor temperature)Installation box for adaptor PCBExternal control adaptor for outdoor unitMulti tenant unit for Indoor (24 V free type)

FXFSQ-A

BRC1E63 *5

BRC2E61

BRC7M635F (Fresh White) BRC7M635K (Black)

BRC7M531W (for grid ceiling panel)BRC7E531W (for decoration panel) BRC7M66 BRC4M63 BRC4M66 BRC4C66

BRC7M634F (Fresh White)BRC7M634K (Black)

BRC7M530W (for grid ceiling panel)BRC7E530W (for decoration panel) BRC7M65 BRC4M61 BRC4M65 BRC4C65

— BRP11B62 BRP11B61— BRP11B62

BRC1E63

— KRP1C14A

KRP2A51 — — KRP2A53 KRP2A61 KRP2A62—

KRP4AA53 KRP4AA51 — KRP4A54 — KRP4AA51

BRCS01A-5 BRCS01A-6 BRCS01A-4 BRCS01A-1 BRCS01A-4

KRP1C96 *2, 3 — KRP1BB101 *4 — KRP4A98 *2, 3KRP1BB101 *4KRP1H98A *2, 3

DTA104A61 — DTA104A53 — DTA104A61 DTA104A62

BRC1F61 BRC1F61 *5 BRC1E63

BRC2E61

FXFQ-A

Stylish remote controller

Navigation remote controller

Simplified remote controller

C/O

H/P

Wireless remote controller

Wireless remote controller

Adaptor for wiring (operation status output)

Adaptor for wiring

Wiring adaptor for electrical appendices (1)Wiring adaptor for electrical appendices (2)Remote sensor (for indoor temperature)Installation box for adaptor PCBExternal control adaptor for outdoor unitMulti tenant unit for Indoor (24 V free type)

FXMQ-PA FXMQ-P FXUQ-A FXHQ-MA

BRC1H61W (White) / BRC1H61K (Black)

BRC1E63 BRC1E63 *6 BRC1E63BRC1E63 *5BRC1E63

BRC2E61

BRC7EA66 BRC7M56 BRC7M676 BRC4C64 — BRC4C64BRC4C66 BRC7CB59

BRC4C65 BRC7CB58 BRC7EA63W BRC7M53 BRC7M675 BRC4C62 — BRC4C62

BRP11B61 — BRP11B62 — BRP11B62 BRP11B62 —

KRP1C13A — KRP1C67 KRP1C67 ——

KRP2A62 — KRP2A61 KRP2A61 KRP2A62 *8 KRP2A61 KRP2A61 KRP2A61 KRP2A61 —

KRP4AA51 KRP4AA51 KRP4AA53 KRP4AA52 KRP4AA51 KRP4AA51 — KRP4AA51

BRCS01A-4 BRCS01A-6 BRCS01A-4 BRCS01A-1 BRCS01A-4 BRCS01A-6 BRCS01A-1 — BRCS01A-1

KRP1CA93 *3 KRP1D93A *3 KRP4B93 *2, 3 — KRP4A987*2, 3, 10 —KRP1BA97—KRP4A97 *2, 3

DTA104A61 BRCS01A-6 — DTA104A62 DTA104A61 DTA104A61 DTA104A62*8 — DTA104A61

— —

KRP6A1*8

KRCB37-1

FXHQ-A FXAQ-A FXLQ-MAFXNQ-MA FXVQ-N *7 FXPQ-A FXBQ-P

FXBPQ-P

FXZQ-A

BRC1H61W (White) / BRC1H61K (Black)

FXCQ-A FXEQ-A FXDSQ-A FXDQ-SP

BRC1H61W (White) / BRC1H61K (Black)

FXSQ-PAFXDQ-PDFXDQ-ND

External control adaptor for cooling / heating

Remote controller with key

BRP114A61

BRP114A61 BRP114A61

BRP114A61

KRP4AA51*9

TypeItem

TypeItem

225 226

Daikin Engineering SupportsVRV design and sales proposal assistance

Daikin provides engineering supports for VRV systems. It consists of design supports that can assist consultants and architects, as well as sales proposal supports for air conditioning engineers and dealers. We at Daikin provide the software, the simulation results, and drawing materials to support the building information modeling (BIM) currently entering the mainstream in construction industries.

CADXpress is a flexible design software that optimises equipment selection and CAD drawing. It can empower consultants and air conditioning engineers so they can fully enhance their equipment selections to design the most effective, optimum systems possible. The software also allows the choice of outdoor units based on peak loads rather than the sum of required capacities for each indoor unit. This fine-tuning feature reduces VRV system sizes and increases efficiency.Additionally, the CAD function enables automatic calculation of piping diameter and length without any need for CAD software.

Model selection softwareCADXpress

DT FLOW 2 is a simulation software that uses computational fluid dynamics (CFD), aiming to optimise outdoor unit layouts right at the design stage. When discharged air from the outdoor unit is drawn back into the suction vent, it can short circuit the system and lead to: decrease in efficiency of cooling operations, capacity shortages, operation cut-offs, and shorter lifetime for the outdoor unit. To avoid the need for expensive layout modifications once construction is complete, Daikin uses the CFD method at the early design stage. This can help consultants and architects optimise their outdoor unit arrangement.

New software for indoor airflow simulation will be coming soon.Indoor airflow simulation is a method for predicting temperature distribution and velocity distribution of indoor environment.

CFD simulation to optimise outdoor unit layouts DT FLOW 2

CADXpress

DS-HL2 uses ASHRAE’s Radiant Time Series method to compute heat load for a 24-hour period on summer and winter days. The Radiant Time Series considers the delay in heat load coming into the room through outer walls and the roof in the form of conduction and radiation. Airflow calculation for rooms can be performed. Detailed reports are available for different breakdown requirements. Additional monthly calculation is also available with an advanced license tier.24-hour weather data for all major cities is based on data recorded from past years.

Heat load calculation DS-HL2

Users download CAD symbol drawing materials, including 2D CAD symbols and 3D Revit data, for VRV systems designing. The 3D Revit data contains specifications for Daikin products, including things like capacities and electric characteristics to support Building Information Modeling (BIM).

Drawing supportsCAD Symbols

CADXpress

Outdoor unit Indoor unit

Design assistance

Combines energy efficiency and comfort

CFD simulation to optimiseoutdoor unit layouts Heat load calculation

Design flexibility

For consultants and architects

Sales proposalsFor air conditioning engineers and dealers

Drawing materials supportModel selectionHeat load calculation

Model selectionHeat load calculation