I HEN-70_H.264 Encoder USER’S MANUAL V5.6
Contents
Chapter 1: Introduction This first chapter provides a general description of the High Definition HEN-70 encoder.
Chapter 2: Technical features
This second part offers a detailed description of the HEN-70 encoder’s physical and environmental characteristics.
Chapter 3: Encoder operation and Menus This third part provides the user all the necessary information to control and operate the equipment properly. It is detailed the function of each button on
the keyboard. It is also explained how the information is shown on the display, encoder menus, etc.
Chapter 4: GPS Application In this chapter, the use of the GPS incorporated system and some of its
applications are shown.
Chapter 5: Web Server
This chapter provides a detailed description of the Web Server tool. This
feature allows controlling the HEN-70 encoder through a website.
Chapter 6: Equipment Installation
This chapter indicates the available connections of the encoder, their characteristics and the installation of the encoder.
II HEN-70_H.264 Encoder USER’S MANUAL V5.6
Dear customer,
We would like to thank you for selecting this equipment and welcome you to the SVP’s growing family of products.
We are sure that the addition of this equipment will cause you a complete satisfaction in your existing installation.
Please read these instructions carefully, and keep them in hand in case you have to refer to them.
III HEN-70_H.264 Encoder USER’S MANUAL V5.6
About this manual
This user’s guide provides indications and explanations about how to set up the HEN-70 encoder easily for the most common use cases.
This document is intended to help first time users:
- To find their way around the GUI.
- To understand the different possibilities of the HEN-70 encoder.
- To configure the HEN-70 for their specific configurations.
Symbols
The symbols that appear in this manual are:
An information message which indicates explanations for the
proper operation of the equipment.
It advises users that if they do not take, avoid or make specific
actions, several damages could appear in the device.
In the places where this symbol appears it means that by
pressing the Down button of the equipment the user can
access to the next screen.
This symbol means that pressing the OK button in the options
where this symbol appear, the user can access to the submenu
related to that option or can change the value of the
parameter.
<> These symbols mean that the parameter can be modified in the same screen with the right and left keys.
IV HEN-70_H.264 Encoder USER’S MANUAL V5.6
Important Notes
1. The HEN-70 encoder applies an MPEG-4 compression to either HDMI,
composite video, SD-SDI or HD-SDI input signals. An MPEG-1 layer 2
compression is applied to the corresponding 2 analogue audio channels, the 2 stereo SDI embedded, the HDMI embedded and the AES digital
audio signals. 2. Special care should be taken with SDI cables, quality and length, these
are very important, especially when HD-SDI or 3G-SDI signals are transmitted.
3. This device has the ASI and IP output available when the input is ASI.
Besides, it also has the ASI output available when the input is IP.
4. In 1080p Video Format, it can only be performed the Standard Delay,
not the Low Delay, the Super Low Delay or the Ultra Low Delay.
5. In case it is selected SDI input with 1080p format, the delay will be automatically Standard.
6. If any audio or data channel are not used in a transmission, they should be disabled, in order to assign that bitrate to the video and achieve a
higher quality transmitted video signal. 7. Only authorized personnel should open the product and any repair or
warranty will be invalidated if the seals are broken.
V HEN-70_H.264 Encoder USER’S MANUAL V5.6
First Aid in Case of Electric Shock
DO NOT TOUCH THE VICTIM WITH YOUR BARE HANDS until the circuit is broken. SWITCH OFF. If this is not possible, PROTECT YOURSELF with DRY
insulating material and pull the victim clear of the conductor.
If breathing has stopped, indicated by unconsciousness, lack of respiratory movements and a ‘blue’ look to cheeks, lips, ears and nails, START RESUSCITATION AT ONCE.
EMERGENCY RESUSCITATION – THE EXPIRED AIR METHOD
(Approved by the Royal Life Saving Society)
1. If possible, lie the victim on his back with his head slightly higher
than his feet. Clear the mouth and throat of any obvious obstruction.
2. Kneel on one side of the victim, level with his head. LIFT THE JAW AND TILT THE HEAD BACK AS FAR AS POSSIBLE (Figs. 1a and 1b)
3. One of the following may happen: a) Breathing may begin and consciousness return.
b) Breathing may begin but consciousness NOT return. Turn the victim on his side and ensure
that the airway is kept clear. c) Breathing may return but be NOISY which
means that the airway is not fully clear. Try to
clear the airway.
4. IF THERE NO SIGN OF BREATHING: a) Check that the head is still tilted back. b) Take a deep breath.
c) Pinch the victim’s nose and blow firmly into his mouth (Fig. 2). As you do, the chest will RISE.
d) Turn your head away and take another breath, watching for the chest to FALL (Fig. 3).
5. Start with four quick breaths and then continue with one breath every five seconds (i.e. 12 times a
minute). This should be continued until the victim revives or a doctor certifies death.
6. As consciousness returns the victim will start to breathe on his own, and a ‘pink’ color replaces the
‘blue’ look: this is the time to stop resuscitation. Continue to hold his chin up and so keep the airway clear.
7. In the case of injuries to the mouth, it may be necessary to use
mouth-to-nose resuscitation. Seal the victim’s mouth with your cheek and blow firmly into his nose, proceeding as above.
VI HEN-70_H.264 Encoder USER’S MANUAL V5.6
8. In the case of severe facial injuries it may be necessary to do a manual method of artificial respiration (Silvester-Brosch or Holger
Nielsen). Briefly, these methods apply compression to ribcage with the victim lying on his back (S-B) or face down (H.N.) with associated movement of his arms up and out. The cycle of movement should
take about five seconds, i.e. the normal breathing phase.
9. Whatever the method, it is ESSENTIAL to commence resuscitation WITHOUT DELAY and to send for medical assistance immediately.
TREATMENT FOR BURNS
If the victim is also suffering from burns, then, without hindrance to resuscitation, observe the following:
a) DO NOT ATTEMP TO REMOVE CLOTHING ADHERING TO THE BURN.
b) If possible alleviate the pain from the burnt part by immersing in cold water.
c) If help as available or as soon as resuscitation is no longer required
the wound should be covered with a DRY clean dressing.
d) Oil or grease in any form should not be applied.
e) If severely burnt, get the victim to hospital immediately.
7 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Main Index
Chapter 1: Introduction ....................................................................... 9
Chapter 2: Technical Features ............................................................. 10
Chapter 3: Encoder Operation and Menus ............................................. 13
3.1 Display .................................................................................. 13
3.2 LEDs ..................................................................................... 16
3.3 Front panel ............................................................................ 17
3.3.1 ON/OFF Button ................................................................. 17 3.3.2 OK Button ........................................................................ 18 3.3.3 Cross Button .................................................................... 18 3.3.4 Left and Right Button ........................................................ 19 3.3.5 Up and Down Button ......................................................... 19
3.4 Menus ................................................................................... 20
3.4.1 Menu Navigation ............................................................... 25 3.4.2 Menu Structure ................................................................. 26
3.4.2.1 Encoder Menu ............................................................. 27 3.4.2.1.1 SDI Input .............................................................. 29 3.4.2.1.2 HDMI Input ........................................................... 31 3.4.2.1.3 CVBS Input ........................................................... 33 3.4.2.1.4 ASI Input .............................................................. 35 3.4.2.1.5 IP Input ................................................................ 36 3.4.2.1.6 Generator Input ..................................................... 40 3.4.2.1.7 Audio1 Embedded .................................................. 41 3.4.2.1.8 Audio1 Analogue .................................................... 42 3.4.2.1.9 Audio1 AES-EBU .................................................... 43 3.4.2.1.10 Audio1 Tone.Gen ................................................. 44 3.4.2.1.11 Audio2 Embedded ................................................ 45 3.4.2.1.12 Audio2 Analogue .................................................. 46 3.4.2.1.13 Audio2 AES-EBU .................................................. 47 3.4.2.1.14 Audio2 Tone.Gen ................................................. 48 3.4.2.1.15 Data ................................................................... 49 3.4.2.1.16 Encoder Output ................................................... 52 3.4.2.1.17 TS Parameters ..................................................... 53
3.4.2.2 CA-BISS Menu ............................................................ 56 3.4.2.3 IP Out ........................................................................ 58 3.4.2.4 Unit Menu ................................................................... 60
3.4.2.4.1 Alarms .................................................................. 60 3.4.2.4.2 Monitor ................................................................. 61 3.4.2.4.3 Webserver & SNMP ................................................ 62 3.4.2.4.4 Miscellaneous ........................................................ 64 3.4.2.4.5 Firmware .............................................................. 66 3.4.2.4.6 BUC S/S2 Unit ....................................................... 70
Chapter 4: GPS Application ................................................................. 71
8 HEN-70_H.264 Encoder USER’S MANUAL V5.6
4.1 Introduction ........................................................................... 71
4.2 Main Screen ........................................................................... 71
4.3 GPS encoder screen ................................................................ 72
4.4 Application example ................................................................ 73
Chapter 5: Web Server ....................................................................... 75
5.1 Introduction ........................................................................... 75
5.2 Web Page Overview ................................................................ 77
5.2.1 ENCODER ......................................................................... 78 5.2.1.1 Video ......................................................................... 78 5.2.1.2 Audio ......................................................................... 79 5.2.1.3 Data .......................................................................... 80
5.2.1.3.1 RS-232 ................................................................. 80 5.2.1.3.2 GPS...................................................................... 81
5.2.1.4 TS Parameters ............................................................ 82 5.2.1.5 Output ....................................................................... 83
5.2.2 TSoIP .............................................................................. 84 5.2.2.1 IP Output ................................................................... 85 5.2.2.2 IP Input ..................................................................... 86 5.2.2.3 IP Input ..................................................................... 87
5.2.3 CA-BISS .......................................................................... 89 5.2.4 UNIT ............................................................................... 90
5.2.4.1 LEDs Status (reading parameters) ................................. 90 5.2.4.2 Alarms (reading parameter) .......................................... 91 5.2.4.3 Configuration .............................................................. 91 5.2.4.4 Monitor ...................................................................... 92
5.3 Web Page Setup Notes ............................................................ 94
5.4 SNMP .................................................................................... 94
5.4.1 SNMP commands .............................................................. 95 Chapter 6: Equipment Installation ....................................................... 96
6.1 Introduction ........................................................................... 96
6.2 Connections ........................................................................... 96
6.2.1 Power supply .................................................................... 98 AC Power supply ....................................................................... 98 DC Power supply ....................................................................... 99
6.2.2 ASI ............................................................................... 101 ASI input ................................................................................ 101 ASI output .............................................................................. 101
6.2.3 CVBS/ SDI/ HDMI ........................................................... 102 6.2.4 Transport Stream over IP ................................................. 103
Transport Stream over IP Input and Output ................................ 103 6.2.5 Audio inputs ................................................................... 104 6.2.6 Data/GPS input ............................................................... 106 6.2.7 USB connection .............................................................. 107 6.2.8 Ethernet ........................................................................ 107
9 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Chapter 1: Introduction
The HEN-70 is the new encoder developed by SVP Broadcast Microwave. SVP has reached the state of the art with this encoder, so it is ideal for
portable use when the highest quality available on the market is required. This device is a H.264 encoder, which can work with SD and HD input
signals, being able to detect automatically the video input format. For added security, the signal can be encrypted using the BISS encryption technology.
This encoder has several analogue and digital video interfaces (3G-SDI, HD-
SDI, SD-SDI, HDMI and CVBS) as well as several audio interfaces (SDI embedded, AES digital, HDMI embedded and Analogue).
The HEN-70 also provides a network interface for Transport Stream over IP based networks as well as ASI output. It allows sending the signals over IP
based networks. It allows the remote control of block up-converters for satellite applications.
The small size and lightweight make the HEN-70 encoder the suitable
equipment to be used in broadcast and professional applications, such as satellite uplinks, point-to-point radio links and many other uses.
10 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Chapter 2: Technical Features
Encoder
Video compression: H.264/MPEG-4 Part 10
Profile: High 422, High, Main
Level: 3.0/3.1/3.2/4.0/4.1
Latency: Ultra Low delay: 33 ms Audio compression: MPEG-1 Layer II
Audio bit rate: 128, 192, 256 or 384 Kbps
Output bit rate: 1 Mbps – 100 Mbps
Encryption
BISS: BISS-1 and BISS-E
AES: AES-128 and AES-256 (Optional)
Video: Inputs: 3G-SDI SMPTE-425M-A(299M)
HD-SDI SMPTE-292M(299M) SD-SDI SMPTE-259M(272M)
HDMI (1.4a) Composite video (PAL/NTSC)
Formats: 1080p (1920x1080) – 23.98/24/25/ 29.97/30/50/59.94/60 Hz
1080i (1920x1080) – 50/59.94/60 Hz 720p (1280x720) – 23.98/24/25/29.97/ 30/50/59.94/60 Hz
576i (720x576) – 50 Hz 480i (720x480) – 59.94 Hz
11 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Audio:
Input: SDI embedded / HDMI embedded
AES Digital / Analogue Analogue: 2 Stereo / 4 Mono
Line, Micro Dynamic and Micro with Phantom
SDI embedded: 1 Group (4 audio channels)
AES/EBU: 2 Stereo channels
Data Channels
Data channel: User data or GPS
Data rate: 1.200 to 57.600 bps
Test Signals
Video: Bars with moving icon
Audio: 4 Audio tones
ASI and IP
Input and Output: ASI Transport Stream (EN50083-9) Transport Stream over IP (SMPTE2022/CoP3) - FEC
188/204 byte-packets Max. TS packets / IP packet: 7
Control & Monitorization
Control Interfaces: Front panel & display
Web Server SNMP RTC-01 via cable
Monitoring: Encoding parameters
Status Alarms and warnings.
12 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Power Supply
AC input: 100 to 240V
DC input: 8 to 36 V
Consumption: <20W
Mechanical
Size: 1/2 RU, 210 x 44 x 240 mm (WxHxD)
Weight: 1,8 Kg
Environmental
Temperature range: -10 to 45 ºC
Height: 4.500 m Humidity: 95%
13 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Chapter 3: Encoder Operation and Menus This third chapter provides the user all the necessary information to control,
configure and operate the equipment properly.
3.1 Display
To switch the equipment on and off, press the ON/OFF button. When the equipment is turned on, the display will show the start-up message (model
and version of the equipment) for two seconds. When a video, audio or data input has been selected, a character connected
to this input is displayed in the main screen.
Next, the main screen of the HEN-70 encoder is shown.
Figure 3.1 HEN-70 front panel/ Main screen explanation
ENCODER HEN-70 Bitrate: 30.0 Mbps
239.192.000.001:5678 GAEX 576/50i 420S XXX/XX
Video Input Selection
Audio Input Selection
Data Input Selection
FEC
Input Video Signal Format
Bitrate
Latency
Encoder Video Profile
IP Port
14 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Once an option has been selected, the main screen appears and these parameters are displayed:
Transmitted bitrate (Mbps). IP address.
Port number. Video input selection
- Possibilities: CVBS, HDMI, SDI, DVB-ASI Transport Stream or Generator.
- Behaviour of the corresponding character: If the character is
static then it means presence of that signal. If the character is blinking then it means absence of that signal.
Audio status indication: If audio 1 or 2 is not darkened then it is
enabled. On the other hand, if audio 1 or 2 is darkened then it is disabled.
Data status indication: If this field is not darkened then it means that
data is enabled. On the other hand, if this value is darkened it means that data is disabled. Moreover, in case this field is static, its meaning is
presence of the data whereas if this field is blinking, it means absence of the data.
Input video signal format.
Encoder Video Profile (4.2.0 or 4.2.2). Latency (Standard delay, Low delay, Super Low Delay or Ultra Low
Delay) - Standard Delay (Lipsync < 10 ms) - Low delay (Lipsync < 10 ms) 3 frame
- Super Low Delay (Lipsync < 10 ms) 2 frame - Ultra Low Delay (Lipsync = 20 ms) 1 frame
15 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Next, the linkages between the input and the character displayed in the principal screen are shown:
Video
CVBS
C
HDMI
H
SDI
S
ASI
ASI
IP
I
Test Pattern
G
Audio
Embedded
E
AES/EBU
U
Analogue
A
Test Tone
G
Data
RS232
D
GPS
G
Table 3.1 Linkages between the input and the character displayed
16 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.2 LEDs
The HEN-70 encoder has 4 Leds on its front panel that show the information detailed below.
The ON/OFF provides the following information:
If the Led is off, the equipment is not being fed. If the Led flickers in red, there is power into the equipment but it is
turned off. The Led lights up in green when the equipment is turned on.
The ALARM LED provides the following information:
The LED lights up in red when any alarm occurs. The different alarms that can appear in the transmitter are:
- Voltage High or Low.
- Temperature High. - ASI Overflow: This alarm means that the input bitrate is higher than
the one that can be modulated due to the parameters configured
(constellation, FEC, GI...).
The different warnings that can appear in the transmitter are:
- No Video Input.
- No GPS.
The HPA ALARM LED provides the following information: The LED lights up in green when a BUC is connected to the HDT-70. It is
used in satellite transmission standards.
The STATUS LED: The LED lights up when a change in the configuration of the device is
being processed.
MOD LED and CARRIER LED: These LEDs light up when DVB-S2 transmission standard is being used.
Figure 3.2 HEN-70 LEDs
ON/OFF LED
ALARM LED
ALARM LED
STATUS LED
MOD LED
CARRIER LED
17 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.3 Front panel The HEN-70 encoder is configured following a menus structure on the display. The front panel has 8 buttons to enter and exit the equipment’s
control menus and submenus and to navigate through them. The function of each button is detailed in the following sections.
Figure 3.3 HEN-70 front panel
3.3.1 ON/OFF Button
To switch the equipment on and off, press this button. When the equipment
is turned on, the display will show the start-up message (model and version of the equipment), and then it will display the main screen.
If the power fails while the equipment is operating, it will restart
automatically when the power returns, not being necessary to press the on/off button again.
Figure 3.4 ON/OFF button
Fan Display
Left Button
UP Button
Right Button
OK Button
Down Button
Cross Button
ON/OFF Button LEDs
TX Button
18 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.3.2 OK Button
This button is used to: Enter to submenus and change parameters. So as to access to a
submenu, OK button must be pressed. Moreover, in the fields where the enter symbol appears, by pressing the OK button the user can
change the values of the parameter selected. Besides, so as to save the introduced value, the OK button must be pressed.
In case of being in the main screen, pressing the OK button allows the user to access to the alarms screen where there are the different alarms
that are taking place. So as to return to the main screen, the cross button must be pressed.
Figure 3.5 OK button
3.3.3 Cross Button
This button is used to:
Enter from the equipment’s monitor menu to the setup menu and vice
versa.
Exit equipment’s submenus.
This button allows the user to access to the main screen from the alarms
screen.
Figure 3.6 Cross button
OK
X
19 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.3.4 Left and Right Button
These buttons are used to: Once the parameter to change has been selected, they are used to move
the cursor towards the digit immediately on the left or right and to select a parameter from different options.
Figure 3.7 Left and Right buttons
3.3.5 Up and Down Button
The up and down arrow buttons allow navigation in the main menu and
the rest of submenus. Using this buttons the user can enter to a submenu or change a parameter. Once selected, the OK button must be
pressed.
These buttons are also used to change some parameter’s values.
Pressing up and down arrows the value of those parameters can be changed, increased or decreased respectively, for example, in the BISS
encryption, the values of the introduced characters.
Figure 3.8 Up and Down buttons
20 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4 Menus There is one menu in this encoder which allows the user to change the encoder’s parameters and configure them.
To enter the menu of this equipment the cross button should be pressed.
In case it is wanted to return again to the main screen from the menu, the cross button must be pressed. Furthermore, in case of being in the submenus area, returning to the mainly screens is achieved by pressing the
cross button as much times as it is needed.
In the next page, a scheme that specifies the different menu options available is shown.
21 HEN-70_H.264 Encoder USER’S MANUAL V5.6
HEN-70 MENU STRUCTURE
continued
Format
Encoder
Video
MAIN SCREEN
Latency, output bitrate, audio and video status, profile.
SDI HDMI CVBS ASI IP
L Type
Format Status Format
Delay
Profile
Delay
Profile Profile
Delay
Format
Bitrate
Profile
Delay
Analogue Embedded AES-EBU Tone.Gen None
Audio 1
Bitrate Bitrate Bitrate Bitrate
Frequency
Level
continued
Format
GOP GOP GOP GOP
R Type
Gp
DID
GEN
Local IP
IP.Adr
Fec
Port
Out.Delay
TP per IP
Status
Protocol
Packet
Size
BitRate
PCR
22 HEN-70_H.264 Encoder USER’S MANUAL V5.6
continued
continued
continued
continued
Audio 2
Data
Analogue Embedded AES-EBU Tone.Gen None None GPS RS232
Bitrate
L Type
Bitrate Bitrate Bitrate
Frequency
Level
BaudRate
Parity
Stop Bits
Encoder
Output
Bitrate
Encoder
R Type
Gp
DID
23 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Local IP
DestinationIP&Port
Fec
TP per IP
Protocol
TTL
IP Out
TS
Parameters
Video PID
Audio1 PID
PMT PID
PCR PID
Data PID
Program Nº
Network
Name Audio2 PID
TS id
Network id
Service Name
CA-BISS
Mode
SW
User
None
BISS-1
BISS-E
Encoder
24 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Unit
Alarms
Monitor
Webserver
& SNMP
Miscellaneous
BUC S/S2
Unit
Self Check
Temp
Voltage
Local
Mask
Gateway
MAC
Admin Pass
Restore Admin Pass
User Pass
Restore User Pass
Keyboard Beep
Keyboard Lock
Night Mode
Dist Units
S/N
Firmware
Update Firmware
Restore Default
Rv
Alarms
Temp
Typ
MAC
25 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.1 Menu Navigation
This section contains a detailed description of each parameter that can be
configured in the HEN-70 encoder via the MENU.
To enter the MENU, press the cross button in case of being in the main screen or in any submenu.
To select a parameter or a submenu use Up, Down arrows. Once selected, press the OK button to access to a submenu or to edit a parameter. To exit
a submenu or a parameter, press the cross button.
Figure means that to have access to the right image that button
must be pushed. Symbols <> mean that the parameter can be modified in the same screen
with the right and left keys.
Symbol means that pushing the OK button allows entering the options of the submenu.
Different types of parameters are available:
- Eligible: When the user can choose between predetermined
states. (They usually have the symbol <> near to them)
- Editable: When the user must enter a value in that option. (They
usually have the symbol near them). So as to save the introduced value, the OK button must be pressed.
- Reading: When the value of that parameter is a monitored
parameter that can’t be changed.
To change any parameter, press the OK button in the desired option and
then with the Up, Down buttons choose the value. Once the parameter is set, press OK so as to changes are done.
Next, the different menus and submenus with the options and eligible parameters are shown. Furthermore, in each figure, example parameters
are shown.
26 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2 Menu Structure
The following menu screen can be accessed by pressing the cross key from the monitoring menu.
Figure 3.9 Menu
Encoder – All the parameters related to the video, audio and data inputs are configured here. Besides, all video, audio, data encoding and multiplexing parameters are accessed here.
CA-BISS – The encryption of signals can be configured in this option.
IP Out – All the parameters related to the IP output are configured in this section.
Unit – Parameters related to the Web Server and other internal options of
the HEN-70 are configured here, as well as other characteristics of the device.
MAIN MENU Encoder IP Out
CA-BISS Unit
27 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1 Encoder Menu
By using the Up, Down arrow keys, select the Encoder option and press the OK key.
Figure 3.10 Encoder Menu
Line nº Function
1
Video:
In this field, the video input must be chosen with the Right and Left
buttons. Once the video input has been selected, press the OK
button so as to configure the parameters related to it.
The available options are:
SDI
HDMI
CVBS
ASI
IP
GEN
2
Audio 1:
In this field, the sort of audio signal introduced in the audio 1 input
can be chosen with right and left buttons. Once the audio 1 input
has been selected, press the OK button so as to configure the
parameters related to it.
The available options are:
Embedded
Analogue
AES-EBU
Tone.Gen
None
3
Audio 2:
In this field, the sort of audio signal introduced in the audio 2 input
can be chosen with right and left buttons. Once the audio 2 input
has been selected, press the OK button so as to configure the
parameters related to it.
ENCODER Video: SDI <> Audio1: Tone.Gen <>
Audio2: AES-EBU <>
ENCODER Data: GPS <> Encoder Output
TS Parameters
28 HEN-70_H.264 Encoder USER’S MANUAL V5.6
The available options are:
Embedded
Analogue
AES-EBU
Tone.Gen
None
4
Data:
In this field, the sort of data input can be selected.
The available options are:
None
GPS
RS-232
5
Encoder Output:
In this field, the encoder output can be selected. Pressing the OK
button, the output bitrate can be configured.
6
TS Parameters:
This file consists on the configuration of the parameters of the
Transport Stream. In this option, the different program identifiers
are configured.
Table 3.2 Encoder Menu
29 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.1 SDI Input
Figure 3.11 SDI Input Menu
Line nº Function
1
Format (SDI):
In this field, the format of the SDI input signal is displayed. (reading
parameter)
The available options are:
1080p (1920x1080) – 23.98/24/25/29.97/30/50/59.94/60 Hz
1080i (1920x1080) – 50/59.94/60 Hz
720p (1280x720) – 23.98/24/25/29.97/30/50/59.94/60 Hz
576i (720x576) – 50 Hz
480i (720x480) – 59.94 Hz
2
Delay:
In this field, the delay of the coding process is configured. So as to
select the desired delay, press Right, Left arrows buttons. (eligible
parameter)
The available options are:
Standard
Low Delay (3 frames of delay)
Super Low Delay (2 frames of delay)
Ultra Low Delay (1 frame of delay)
3
Profile:
In this field, the codification profile can be configured. So as to
select the desired profile, press Right, Left arrows buttons. (eligible
parameter)
The available options are:
4.2.0
4.2.2
ENCODER VIDEO SDI
Format: 1080/50i Delay: SuperLD 2F <> Profile: 4.2.0 >
ENCODER VIDEO SDI
GOP: Auto 12 >
30 HEN-70_H.264 Encoder USER’S MANUAL V5.6
4
GOP:
In this field, the group of figures parameter is displayed. It specifies
the order in which intra- and inter-frames are arranged. (eligible
parameter)
The available options are:
Auto
Manual (editable parameter)
Table 3.3 SDI Input menu options
In case HDMI video input is selected, it is necessary to specify the format
(1080p, 1080i, 720p). If any other video input (SDI, CVBS or ASI) is selected, then the encoder automatically captures its format and the frame rate. If the video format is changed, the time detection of this new format is
less than 15 seconds.
31 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.2 HDMI Input
Figure 3.12 HDMI Input Menu
Line nº Function
1
Format:
In this field, the format of the HDMI input signal must be selected.
So as to select a format first, press the OK button so as to enter to
the submenus where different formats available appear. Then,
choose the desired one with the UP, Down keys. (editable
parameter)
The available options are:
1080p (Only Standard Delay)
1080i
720p
2
Delay:
In this field, the delay of the coding process is configured. So as to
select the desired delay, press Right, Left arrows buttons. (eligible
parameter)
The available options are:
Standard
Low Delay (3 frames of delay)
Super Low Delay (2 frames of delay)
Ultra Low Delay (1 frame of delay)
3
Profile:
In this field, the codification profile can be configured. So as to
select the desired profile, press Right, Left arrows buttons. (editable
parameter)
The available options are:
4.2.0
4.2.2
ENCODER VIDEO HDMI
Format: 1080p Delay: Standard > Profile: 4.2.0 >
ENCODER VIDEO HDMI
GOP: Auto 12 >
32 HEN-70_H.264 Encoder USER’S MANUAL V5.6
4
GOP:
In this field, the group of figures parameter is displayed. It specifies
the order in which intra- and inter-frames are arranged. (eligible
parameter)
The available options are:
Auto
Manual (editable parameter)
Table 3.4 HDMI Input menu options
33 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.3 CVBS Input
Figure 3.13 CVBS Input Menu
Line nº Function
1
Format (CVBS):
In this field, the format of the CVBS input signal is displayed.
(reading parameter)
The available options are:
480i
576i
2
Delay:
In this field, the delay of the coding process is configured. So as to
select the desired delay, press Right, Left arrows buttons. (eligible
parameter)
The available options are:
Standard
Low Delay (3 frames of delay)
Super Low Delay (2 frames of delay)
Ultra Low Delay (1 frame of delay)
3
Profile:
In this field, the codification profile can be configured. So as to
select the desired profile, press Right, Left arrows buttons. (eligible
parameter)
The available options are:
4.2.0
4.2.2
ENCODER VIDEO CVBS
Format: 480i Delay: SuperLD 2F <> Profile: 4.2.0 >
ENCODER VIDEO CVBS
GOP: Auto 12 >
34 HEN-70_H.264 Encoder USER’S MANUAL V5.6
4
GOP:
In this field, the group of figures parameter is displayed. It specifies
the order in which intra- and inter-frames are arranged. (eligible
parameter)
The available options are:
Auto
Manual (editable parameter)
Table 3.5 CVBS Input menu options
35 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.4 ASI Input
Figure 3.14 ASI Input Menu
Line nº Function
1
Status:
In this field it is indicated if there is any ASI signal in the ASI input.
In case there is an ASI signal, this field will display the word
present. If there is no ASI signal then, no present will be displayed.
(reading parameter)
The available options are:
Present
No Present
2
Bitrate:
Here, the bitrate of the ASI input signal is shown. (reading
parameter)
3
Format:
In this field, the format of the ASI input signal is shown. (reading
parameter)
The available options are:
188 bytes
204 bytes
Table 3.6 ASI Input menu options
ASI INPUT
Status: Present Bitrate: 18.0Mb Format: 188
36 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.5 IP Input
Figure 3.15 IP Input Menu
IP INPUT
Local IP IP.Adr: Unicast >
Fec: Disable >
IP INPUT Port: 5600
Out. Delay: 128 ms TP per IP: 1
IP INPUT
Status: ENABLE Protocol: UDP
Packet Size: 188
IP INPUT BitRate: 0.00Mb
PCR: No Present
37 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Line nº Function
1
Local IP:
So as to configure the network parameters, press the OK button.
(editable parameters)
The available options are:
Local IP:
So as to establish the Local IP address, press the OK button and
then, with the UP, Down buttons change the value. If the user
wants to change from one character to another, press the Right,
Left buttons. So as to save the introduced value, press the OK
button. If this IP is the same as the IP for remote control
(Webserver / SNMP), the device shows a warning message.
Mask:
In this field the Subnet Mask address must be specified. So as to
establish the Subnet Mask address, press the OK button and
then, with the UP, Down buttons change the value. If the user
wants to change from one character to another, press the Right,
Left buttons. So as to save the introduced value, press the OK
button.
Gateway:
In this field the Gateway address must be specified. So as to
establish the Gateway address, press the OK button and then,
with the UP, Down buttons change the value. If the user wants
to change from one character to another, press the Right, Left
buttons. So as to save the introduced value, press the OK
button.
MAC Address:
The MAC address of the device is shown in the screen. (reading
parameter)
2
IP.Adr:
So as to select the short of address from which IP information is
received, press Right, Left buttons. (eligible parameters)
The available options are:
Unicast:
In case it is wanted to receive the signal from any single IP
address to this device, unicast option must be chosen.
Multicast:
In case the signal is received from a multicast address, that
multicast address must be configured in this field. So as to enter
the multicast address, press the OK button so as to be able to
configure the multicast address. (editable parameter)
38 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3
Fec:
So as to select if FEC is enabled or disabled in the received signal
press Right, Left buttons. (eligible parameter)
The available options are:
Enable Col: Row: (The IP Forward Error Correction is
composed by a number of FEC columns and rows. In this field it
is shown the number of FEC columns and rows of the received
signal) (reading parameter)
Disable
4
Port:
This field must be filled in with the port number of the decoder
device through which is going to receive the signal. So as to edit this
parameter, press the OK button and then, select the desired port
with the Up, Down, or Right, Left buttons. So as to save the
introduced value, press the OK button. (editable parameter)
5
Output Delay [1..9942]ms:
This delay means the time passed between the Transport Stream is
obtained in the decoder and the signal is taken out from the
decoder. So as to edit this parameter, press the OK button and then,
select the desired port with the Up, Down and Right, Left buttons.
So as to save the introduced value, press the OK button. (editable
parameter)
6
TP per IP:
This field displays the number of TS packets per IP packet. (reading
parameter)
7
Status:
This field displays the status of the IP input. (reading parameter)
8
Protocol:
This field displays the protocol used for the communication. (reading
parameter)
The possible options are:
UDP
RTP
39 HEN-70_H.264 Encoder USER’S MANUAL V5.6
9
Packet Size:
This field shows the size in bytes of the IP received packets.
(reading parameter)
10
BitRate:
This field displays the bitrate of the received signal. (reading
parameter)
11
PCR:
Program Clock Reference. To enable a decoder to present
synchronized content, such as audio tracks matching the associated
video, at least once each 100 ms a Program Clock Reference, or PCR
is transmitted in the adaptation field of an MPEG-2 transport stream
packet. The parameters displayed can be present or no present.
(reading parameter)
Table 3.7 IP Input Select menu option
If the IP input is selected then, the IP output option blinks due to it cannot
be used because it is already configured as IP input.
40 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.6 Generator Input
Figure 3.16 Generator Input Menu
Line nº Function
1
Format:
In this field the format of the video signal generated is displayed.
The only option available is 576/50i. (reading parameter)
2
Delay:
In this field, the delay of the coding process is configured. So as to
select the desired delay, press Right, Left arrows buttons. (eligible
parameter)
The available options are:
Standard
Low Delay (3 frames of delay)
Super Low Delay (2 frames of delay)
Ultra Low Delay (1 frame of delay)
3
Profile:
In this field, the codification profile can be configured. So as to
select the desired profile, press Right, Left arrows buttons. (eligible
parameter)
The available options are:
4.2.0
4.2.2
4
GOP:
In this field, the group of figures parameter is displayed. It specifies
the order in which intra- and inter-frames are arranged. (eligible
parameter)
The available options are:
Auto
Manual (editable parameter)
Table 3.8 Generator Input menu
ENCODER VIDEO GEN
Format: 576/50i Delay: SuperLD 2F <> Profile: 4.2.0 >
ENCODER VIDEO GEN
GOP: Auto 12 >
41 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.7 Audio1 Embedded
Figure 3.17 Audio Embedded Input Menu
Line nº Function
1
Bitrate:
In this option, the bitrate for the codification of the audio signal 1
can be selected. So as to select the desired bitrate, press Right, Left
arrows buttons. (eligible parameter)
The available options are:
128K
192K
256K
384K
2
Group:
In this field the different numbers of input groups are displayed. In
case one group is not present then, a line appears. (reading
parameter)
DID:
In this field, the desired group can be selected. So as to select the
group, press Right, Left buttons. (eligible parameter)
The available options are:
G0
G1
G2
G3
Table 3.9 Audio Embedded Input menu options
If the video option selected is CVBS, ASI, IP or Test Pattern Generator then, the option of audio embedded will be blinking because that configuration is
not possible.
ENCODER AUDIO1 Bitrate: 256K <>
Gp: (1234) DID:G0 <>
42 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.8 Audio1 Analogue
Figure 3.18 Audio Analogue Input Menu
Line nº Function
1
Bitrate:
In this option, the bitrate for the codification of the audio signal 1
can be selected. So as to select the desired bitrate, press Right, Left
arrows buttons. (eligible parameter)
The available options are:
128K
192K
256K
384K
2
L Type:
In this field, the sort of signal of the audio 1 left channel introduced
in the device is selected. So as to choose the type of audio1, press
Right, Left buttons. (eligible parameter)
The available options are:
Line
Mic Dynamic
Mic Phantom
3
R Type:
In this field, the sort of signal of the audio 1 right channel
introduced in the device is selected. So as to choose the type of
audio1, press Right, Left buttons. (eligible parameter)
The available options are:
Line
Mic Dynamic
Mic Phantom
Table 3.10 Audio Analogue Input menu options
ENCODER AUDIO1 Bitrate: 256K <>
L Type: Line > R Type: Line >
43 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.9 Audio1 AES-EBU
Figure 3.19 Audio AES-EBU Input Menu
Line nº Function
1
Bitrate:
In this option, the bitrate for the codification of the audio signal 1
can be selected. So as to select the desired bitrate, press Right, Left
arrows buttons. (eligible parameter)
The available options are:
128K
192K
256K
384K
Table 3.11 Audio AES-EBU Input menu options
ENCODER AUDIO1 Bitrate: 384K <
44 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.10 Audio1 Tone.Gen
Figure 3.20 Audio Generator Input Menu
Line nº Function
1
Bitrate:
In this option, the bitrate for the codification of the audio signal 1
can be selected. So as to select the desired bitrate, press Right, Left
arrows buttons. (eligible parameter)
The available options are:
128K
192K
256K
384K
2
Frequency (Hz):
In this field, the frequency of the generated tone is displayed.
(reading parameter)
3
Level (dBFs):
In this field, the level in dBF of the generated tone is displayed.
(reading parameter)
Table 3.12 Audio Generator Input menu options
ENCODER AUDIO1
Bitrate: 384K < Frequency: 1000Hz
Level: 18dBFs
45 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.11 Audio2 Embedded
Figure 3.21 Audio Embedded Input Menu
Line nº Function
1
Bitrate:
In this option, the bitrate for the codification of the audio signal 2
can be selected. So as to select the desired bitrate, press Right, Left
arrows buttons. (eligible parameter)
The available options are:
128K
192K
256K
384K
2
Group:
In this field the different numbers of input groups are displayed. In
case one group is not present then, a line appears. (reading
parameter)
DID:
In this field, the desired group can be selected. So as to select the
group, press Right, Left buttons. (eligible parameter)
The available options are:
G0
G1
G2
G3
Table 3.13 Audio Embedded Input menu options
If the video option selected is CVBS, ASI, IP or Test Pattern Generator then,
the option of audio embedded will be blinking because that configuration is not possible.
ENCODER AUDIO2 Bitrate:256K <>
Gp: (1234) DID:G0 <>
46 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.12 Audio2 Analogue
Figure 3.22 Audio Analogue Input Menu
Line nº Function
1
Bitrate:
In this option, the bitrate for the codification of the audio signal 2
can be selected. So as to select the desired bitrate, press Right, Left
arrows buttons. (eligible parameter)
The available options are:
128K
192K
256K
384K
2
L Type:
In this field, the sort of signal of the audio 2 left channel introduced
in the device is selected. So as to choose the type of audio2, press
Right, Left buttons. (eligible parameter)
The available options are:
Line
Mic Dynamic
Mic Phantom
3
R Type:
In this field, the sort of signal of the audio 2 right channel
introduced in the device is selected. So as to choose the type of
audio2, press Right, Left buttons. (eligible parameter)
The available options are:
Line
Mic Dynamic
Mic Phantom
Table 3.14 Audio Input menu options
ENCODER AUDIO2 Bitrate: 256K <>
L Type: Line > R Type: Line >
47 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.13 Audio2 AES-EBU
Figure 3.23 Audio AES-EBU Input Menu
Line nº Function
1
Bitrate:
In this option, the bitrate for the codification of the audio signal 2
can be selected. So as to select the desired bitrate, press Right, Left
arrows buttons. (eligible parameter)
The available options are:
128K
192K
256K
384K
Table 3.15 Audio AES-EBU Input menu options
ENCODER AUDIO2 Bitrate: 384K <
48 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.14 Audio2 Tone.Gen
Figure 3.24 Audio Generator Input Menu
Line nº Function
1
Bitrate:
In this option, the bitrate for the codification of the audio signal 2
can be selected. So as to select the desired bitrate, press Right, Left
arrows buttons. (eligible parameter)
The available options are:
128K
192K
256K
384K
2
Frequency (Hz):
In this field, the frequency of the generated tone is displayed.
(reading parameter)
3
Level (dBFs):
In this field, the level in dBF of the generated tone is displayed.
(reading parameter)
Table 3.16 Audio Generator Input menu options
ENCODER AUDIO2 Bitrate: 384K <>
Frequency: 1000Hz Level: 18dBFs
49 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.15 Data
So as to select the desired sort of data, press Right, Left buttons. (eligible parameter)
The available options are: None, GPS and RS232.
None This option is selected in case no data is sent to the device.
Figure 3.25 None screen
GPS Screen
If this option is selected and the GPS antenna is connected to the GPS input of the device, then, by pressing the OK button, the user can access to the
different parameters sent by the GPS.
So as to access to the GPS screen first, go to the encoder option in the menu. Then, go to the Data option and select GPS with the Right, Left keys. Next, press the OK button so as to access to the GPS screen. Below, there
are shown the different parameters which appear in the GPS screen.
Figure 3.26 GPS screen
#--º--.---´ ---k ---º #---º--.---´ -----mt Satellite Level --/--/--
--:--:--
Level of the satellite signals Time
Date
Height (meters)
Speed(knot)/
Direction(degrees)
Longitude of the encoder
Latitude of the encoder
ENCODER Data: None <
Encoder Output TS Parameters
ENCODER
Data: GPS <> Encoder Output TS Parameters
OK
50 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Next, the different meanings of each field are shown:
Latitude of the encoder: It specifies the latitude position of the
encoder.
Speed of the encoder: It shows the speed of the encoder in knot.
Direction of the encoder: The direction of the encoder is shown in this
field.
Longitude of the encoder: It specifies the longitude position of the
encoder.
Height of the encoder: The height of the encoder from ground is
specified in this value.
Satellite Level: The level of each satellite signal received is shown in
this field.
Date: The updated date is shown.
RS232
If it is wanted to send data to the device through a RS232 connection, this option must be selected. It is also needed to configure the next parameters
so as to achieve a successful communication.
Figure 3.27 RS232 screen
ENCODER Data: RS232 < Encoder Output
TS Parameters
OK
DATA INPUT RS232 BaudRate: 57600 <
Parity: None > Stop Bits: 1 >
51 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Data option Parameters
1
BaudRate:
Select the baudrate at which data user is received. (Baudrate
options are: 1200, 2400, 4800, 9600, 19200, 38400, 57600)
(eligible parameters)
2
Parity:
Select the same parity as the parity of the received data user signal.
(Parity options are None, Even, Odd) (eligible parameters)
3
Stop Bits:
Select the same number of stop bits as the received data user signal
has. (Stop bit options are 1 or 2) (eligible parameter)
Table 3.17 RS232 Parameters
52 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.16 Encoder Output
Figure 3.28 Encoder Output Menu
Line nº Function
1
BitRate:
In this field, the output bitrate is shown. It case it is wanted to
select between an automatic bitrate or configure manually the
bitrate, press Right, Left buttons. If manual configuration is selected
then, press the OK button so as to select the desired bitrate with the
UP, Down keys. Press the OK button so as to save the introduced
value. (eligible parameter)
The available options are:
Auto
Manual (editable parameter)
Table 3.18 Encoder Output menu options
In case the user selects the manual option, if the output bitrate is higher
than the one that is achievable with the selected configuration (modulation
scheme, FEC) then, in the main screen the line (third line) in which these parameters (modulation scheme, FEC, bitrate) appear blinks.
ENCODER OUTPUT
BitRate: 10.0Mb
53 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.1.17 TS Parameters
Figure 3.29 Encoder TS Menu
Line nº Function
1
Service Name:
Here the Service name must be entered. So as to change its value,
first, press the OK button and then, with the UP, Down arrows select
the desired letter. With the Right, Left keys, the user can select the
character of the word. Press the OK button so as to save the
introduced value. (editable parameter)
2
Program Nº:
Here the program number must be entered. So as to change its
value first, press the OK button and then, with the UP, Down arrows
select the desired number. Press the OK button so as to save the
introduced value. (editable parameter)
3
Video PID:
Here the video packet identifier must be entered. So as to change its
value first, press the OK button and then, with the UP, Down arrows
select the desired number. Press the OK button so as to save the
introduced value. (editable parameter)
ENCODER TS
Service Name Program Nº: 1
Video PID: 273
ENCODER TS
Audio 1 PID: 512 Audio 2 PID: 513
Data PID: 2100
ENCODER TS PMT PID: 291 PCR PID: 256
TS id: 7
ENCODER TS Network id: 7
Network Name
54 HEN-70_H.264 Encoder USER’S MANUAL V5.6
4
Audio1 PID:
Here the audio1 packet identifier must be entered. So as to change
its value first, press the OK button and then, with the UP, Down
arrows select the desired number. Press the OK button so as to save
the introduced value. (editable parameter)
5
Audio2 PID:
Here the audio2 packet identifier must be entered. So as to change
its value first, press the OK button and then, with the UP, Down
arrows select the desired number. Press the OK button so as to save
the introduced value. (editable parameter)
6
Data PID:
Here the data packet identifier must be entered. So as to change its
value first, press the OK button and then, with the UP, Down arrows
select the desired number. Press the OK button so as to save the
introduced value. (editable parameter)
7
PMT PID:
Here the program map tables packet identifier must be entered. So
as to change its value first, press the OK button and then, with the
UP, Down arrows select the desired number. Press the OK button so
as to save the introduced value. (editable parameter)
8
PCR PID:
Here the program clock reference packet identifier must be entered.
So as to change its value first, press the OK button and then, with
the UP, Down arrows select the desired number. Press the OK
button so as to save the introduced value. (editable parameter)
9
TS id:
Here the Transport Stream identifier must be entered. So as to
change its value first, press the OK button and then, with the UP,
Down arrows select the desired number. Press the OK button so as
to save the introduced value. (editable parameter)
10
Network id:
Here the Network identifier must be entered. So as to change its
value first, press the OK button and then, with the UP, Down arrows
select the desired number. Press the OK button so as to save the
introduced value. (editable parameter)
55 HEN-70_H.264 Encoder USER’S MANUAL V5.6
11
Network Name:
Here the Network name must be entered. So as to change its value
first, press the OK button and then, with the UP, Down arrows select
the desired letter. With the Right, Left keys, the user can select the
character of the word. Press the OK button so as to save the
introduced value. (editable parameter)
Table 3.19 Encoder TS menu options
56 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.2 CA-BISS Menu
By using the Up, Down arrow keys, select the CA-BISS option and press the OK key.
Figure 3.30 CA-BISS Menu
Line nº Function
1
Mode:
So as to choose the desired encryption, press the Right, Left keys.
(eligible parameter)
The available options are:
None
BISS-1 (Uses an unencrypted key for the BISS key)
BISS-E (Uses an encrypted key)
2
SW:
In this field, the SW password must be introduced, which is valid for
BISS-1 and BISS-E encryption. (editable parameter)
3
User:
In this field, the User password must be introduced, which is valid
only for BISS-E encryption. (editable parameter)
Table 3.20 CA-BISS menu options
CONDITIONAL ACCESS
Mode: BISS-E < SW: *****************
User: ****************
57 HEN-70_H.264 Encoder USER’S MANUAL V5.6
So as to introduce the key in the BISS-1 option, follow these steps:
1. Choose the BISS-1 option in the Mode field. 2. Go one field down (SW) and press the OK button so as to be allowed
to introduce the key. 3. With Left and Right buttons select one field and with UP, Down
buttons choose one value from 0 to 9 or A to F. 4. Press the OK button to set the key.
So as to introduce the key in the BISS-E option, follow these steps:
1. Choose the BISS-E option in the Mode field. 2. Go one field down (SW) and press the OK button so as to be allowed
to introduce the key. 3. With Left and Right buttons select one field and with UP, Down
buttons choose one value from 0 to 9 or A to F.
4. Press the OK button to set the key. 5. Go another field down (User) and press the OK button so as to be
allowed to introduce the User. 6. With Left, Right buttons select one field and with UP and Down
buttons choose one value from 0 to 9 or A to F.
7. Press the OK button to set the User.
BISS encryption is activated in the ASI output.
58 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.3 IP Out
By using the Up, Down arrow keys, select the IP Out option and press the OK key.
Figure 3.31 IP Out Menu
Line nº Function
1
Local IP:
In this option it can be set the IP address, Mask, Gateway and MAC
of the device in case it is wanted to control the device remotely. So
as to change those parameters, press the OK button and then, with
the Up and Down keys select the desired option.
- LOC:
IP address of the device which is going to send the
information. So as to change the IP address first press OK
button and then, with the Up, Down keys select the desired
number. So as to change from one character to another,
press Right, Left keys. So as to save the value, press the OK
button. (editable parameter)
- MSK:
Subnet address of the device which is going to send the
information. So as to change the Subnet Mask address first
press the OK button and then, with the Up, Down keys select
the desired number. So as to change from one character to
another, press Right, Left keys. So as to save the value,
press the OK button. (editable parameter)
- GAT:
Gateway address of the device which is going to send the
information. So as to change the Gateway address first press
the OK button and then, with the Up, Down keys select the
desired number. So as to change from one character to
another, press Right, Left keys. So as to save the value,
press the OK button. (editable parameter)
- MAC ADDRESS
The MAC Address of the transmitter is shown. (reading
parameter)
IP OUT Local IP DestinationIP&Port
Fec: Disable >
IP OUT TP per IP: 7 (1..7) < Protocol: UDP >
TTL: 80 (1...255)
59 HEN-70_H.264 Encoder USER’S MANUAL V5.6
2
Destination IP & Port:
In this option, the IP address and the port number of the device to
which data is sent must be configured. In case it is wanted to send
data to a multicast address just enter the desired multicast address.
So as to change the IP address and the port number, first press the
OK button and then, with the Up, Down keys select the desired
number. So as to change from one character to another, press
Right, Left keys. So as to save the value, press the OK button.
(editable parameter)
3
FEC:
In this field, the Forward Error Correction can be enabled or
disabled. In case it is enabled, the number of columns and rows can
be configured pushing firstly the OK button and then, with the Up,
Down arrows, the number of columns and rows wanted can be
selected. If FEC option is enabled then, the only protocol which can
be used is RTP. (eligible parameter)
4
TP per IP:
In this field, the number of Transport Stream packets per IP (from 1
to 7) can be configured. So as to select the desired value, press the
Right, Left buttons. (eligible parameter)
5
Protocol:
The type of protocol used for the communication can be RTP or UDP.
So as to select the desired protocol for the communication, use
Right, Left buttons. (eligible parameter)
6
TTL:
This field limits the lifetime of data. The Time to Live value (from 1
to 255) means the number of routers that a packet can reach until
that packet is discarded. So as to configure this value, first press the
OK button and then, with the Up, Down, and Right, Left buttons
select the desired value. So as to save the value, press the OK
button. (editable parameter)
Table 3.21 IP OUT menu options
60 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.4 Unit Menu
By using the Up, Down arrow keys, select the Unit option and press the OK key.
Figure 3.32 Unit Menu
3.4.2.4.1 Alarms
In this option, different alarms which are present in the device are shown.
The alarm screen can be accessed by pressing the OK button from the main screen as well. So as to return to the main screen from the alarm screen, cross button must be pressed.
The different alarms that can appear in the transmitter are:
Voltage High. Voltage Low.
Temperature High. ASI Overflow: this alarm means that the input bitrate is higher than
the one that can be modulated due to the parameters configured (constellation, FEC, GI...).
The different warnings that can appear in the transmitter are:
No Video Input. No GPS.
UNIT
Alarms (02) Monitor
Webserver & SNMP
UNIT
Miscellaneous Firmware
BUC S/S2 Unit
61 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.4.2 Monitor
Figure 3.33 Unit Monitor Menu
Temperature:
In this field, the internal temperature of the device is displayed. With
the Right, Left keys, the user can select if the temperature is shown in ºC or in ºF. Also, the value which is between square brackets means the speed of the fans (values from 0 to 3) where 0 means that
the fans are stopped and value 3 is the maximum speed. (Reading parameter)
Voltage:
In this field, the voltage of the device is shown. (Reading parameter)
UNIT MONITOR
Self Check: OK Temp: +37,1ºC (0) >
Voltage: +11.6V
62 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.4.3 Webserver & SNMP
Figure 3.34 Webserver & SNMP Menu
Line nº Function
1
Local IP:
In this option it can be set the IP address of the device in case it is
wanted to control the device remotely. So as to change the IP
address first press the OK button and then, with the Up and Down
keys select the desired number. So as to change from one character
to another, press Right and Left keys. Press the OK button so as to
save the introduced value. (editable parameter)
2
Subnet Mask:
Here, the Subnet Mask address of the device can be written. So as
to change the Subnet Mask address first press the OK button and
then, with the Up and Down keys select the desired number. So as
to change from one character to another, press Right and Left keys.
Press the OK button so as to save the introduced value. (editable
parameter)
3
Gateway:
In this option, the address of the Gateway must be written. So as to
change the Gateway address first, press the OK button and then,
with the Up and Down keys select the desired number. So as to
change from one character to another, press Right and Left keys.
Press the OK button so as to save the introduced value. (editable
parameter)
4
MAC ADDRESS
In this field, the MAC address of the device is shown. (reading
parameter)
UNIT ETHERNET
LOC 192.168.001.010 MSK 255.255.000.000 GAT 192.168.001.001
UNIT ETHERNET
70-B3-D5-1A-C0-00 Admin Pass: ********
Restore Admin Pas
UNIT ETHERNET
User Pass: ******** Restores User Pas
63 HEN-70_H.264 Encoder USER’S MANUAL V5.6
5
Admin Pass:
The administrator’s password is introduced. It can be set an own
password which is a list of 8 digits.
To set the password, press the OK button and the use the Up and
Down button to establish the desired value, the press Right and Left
buttons to change other digits. Finally press the OK button to save
the introduced values.
6
Restore Admin Pass:
This option enables to restore the default administrator password
(00000000).
7
User Pass:
The user’s password is introduced. It can be set an own password
which is a list of 8 digits.
To set the password, press the OK button and then use the Up and
Down button to establish the desired value, the press Right and Left
buttons to change other digits. Finally press the OK button to save
the introduced values.
8
Restore User Pass:
This option enables to restore the default user password
(00000000).
Table 3.22 Unit Ethernet menu options
64 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.4.4 Miscellaneous
Figure 3.35 Miscellaneous Menu
Line nº Function
1
Keyboard Beep:
If the option On is selected then, each time a key is pressed a beep
sound will appear. If the option Off is selected, then, there will not
be sound when a key is pressed. (eligible parameter)
The available options are:
On
Off
2
Keyboard Lock:
If the On option is selected and then, the buttons of the equipment
remain for 5 minutes without being pressed, a message will appear
in the screen saying that the keyboard is locked. Pressing the cross
button, the keyboard can be unlocked. If the Off option is selected
there will be no messages in the screen.
The available options are:
On
Off
3
Night Mode:
There are four possible states for the night mode. If night mode is in
state 0, then the light in the screen will shine more than if it is in
state 1. If the state is three then, the light in the screen will be the
lowest of the four possible states. (eligible parameter)
The available options are:
0
1
2
3
UNIT MISCELLANEOUS
Keyboard Beep: Off < Keyboard Lock: Off < Night Mode: 0 >
UNIT MISCELLANEOUS
Dist Units: Km > S/N: 660010911 70-B3-D5-1A-C0-00
65 HEN-70_H.264 Encoder USER’S MANUAL V5.6
4
Dist Units:
If miles is selected then, all the distances will be in miles and the
same occurs if kilometers is selected. (eligible parameter)
The available options are:
Kilometers
Miles
5
S/N:
In this field the serial number of the device is shown (reading
parameter).
6
MAC Address:
The MAC Address of the transmitter is shown. (reading parameter)
Table 3.23 Unit Miscellaneous menu options
66 HEN-70_H.264 Encoder USER’S MANUAL V5.6
3.4.2.4.5 Firmware
Figure 3.36 Firmware Menu
Line nº Function
1
Update Firmware:
This field is the one for updating the version of the device. So as to
update the equipment properly, follow the instructions below.
2
Restore Default:
In this option, the equipment is restored to the first factory version.
So as to restore the equipment to the initial set up, press the OK
button.
3
Rev:
In this field it is shown the number of the version installed in the
device. The characters which describe the number of the version are
the one inside the red box shown in the figure above. The rest of the
characters are important for the manufacturer but are not important
for the user.
Table 3.24 Unit Firmware menu options
Update Firmware
Restore Default Rev: V5.3901391917-18
Number of the version of the device
67 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Next, the necessary steps so as to make a successful update are explained.
1) The latest firmware is allocated in the webpage of SVP Broadcast Microwave. So as to access to the firmware file, first enter www.svpbm.com in your web browser.
2) Click on the Support tab.
Figure 3.37 Updating firmware step 2
3) Click on Firmware.
68 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Figure 3.38 Updating firmware step 3
4) Go to TX_Firmware.
Figure 3.39 Updating firmware step 4
5) Press the Download button so as to download the file.
69 HEN-70_H.264 Encoder USER’S MANUAL V5.6
To verify the version of the device, go to firmware field and then look
at the Rv option to check the number of the version installed in the device (the first two digits).
Figure 3.40 Updating firmware step 5
6) Once the firmware file has been downloaded, save it in a USB device.
In the USB device, the only file that can be allocated inside it is the
firmware file of the device to be updated.
7) With the equipment completely power off (with no power
supply), insert the USB device in the USB connector, situated in the rear panel.
Before introducing the USB device, remove the power supply of the
equipment.
8) Now, switch on the device.
9) Go to Unit menu. In case of being in the main screen, press cross
button so as to access to the menu. There, with the Up, Down buttons, select the Unit option.
10) Select Firmware by pressing the OK button.
11) Select Check USB Memory with the OK button.
70 HEN-70_H.264 Encoder USER’S MANUAL V5.6
12) Now, automatically the device updates the firmware. The screens
which are shown below display the different steps that the device is making while the updating process.
Don’t power off the device during the updating process.
3.4.2.4.6 BUC S/S2 Unit
Figure 3.41 BUC S/S2 Unit Menu
When a BUC is connected to the device, the followings options of the BUC
are available.
Line nº Function
1
Alarms:
The alarms of the connected BUC are shown.
2
Temperature:
In this option, the temperature of the BUC is shown in the screen.
3
Type:
In this option, the type and the model of the BUC is shown in the
screen.
The available options are:
IRT
WAVE
Table 3.25 BUC S/S2 Unit menu options
Alarms (None) Temp: +40,8 ºC
Typ: IRT (KXB0470) >
71 HEN-70_H.264 Encoder USER’S MANUAL V5.6
69.200
HAUG -------- 420S XXX/XX
Chapter 4: GPS Application
4.1 Introduction The HEN-70 encoder has a GPS antenna input in order to give information
to the device about the positioning data. Connecting the GPS antenna to this input, allows the transference of the information given.
Once the information is kept inside the device, it can be sent from the ASI
or TS over IP output to the MOD-70 modulator and then to the IRD-70. If the signal arrives correctly to the receiver system, then the IRD-70 will have all the GPS data available and this receiver device will be able to
calculate the direction, distance, positioning... of the transmitter.
The IRD-70 also includes another feature that consists on an output RS232 connection which allows watching throughout Google Maps application the position of the transmitter in real time.
Figure 4.1 GPS antenna
4.2 Main Screen
Next it is explained the value of the data field which appears in the main screen of the HEN-70 encoder.
Figure 4.2 Main screen
The data status field indicates with a darkened X that it is disabled. When
this parameter is enabled and blinkers, this means that there is nothing connected to the data input. When this field alternates the value between
‘g’ and ‘G’, it means that it is trying to get the GPS satellites. If the ‘G’ does not vary, then it is connected to the satellites.
72 HEN-70_H.264 Encoder USER’S MANUAL V5.6
4.3 GPS encoder screen So as to access to the GPS screen, go to the encoder option in the menu.
Once inside this option, go to the Data field and choose GPS. Press the OK
button and then the GPS screen appears.
Next, the different field’s meanings are shown.
Figure 4.3 GPS encoder screen
Longitude of the encoder: It specifies the longitude position of the
encoder.
Speed of the encoder: It shows the speed of the encoder in knot.
Direction of the encoder: The direction of the encoder is shown in this
field.
Latitude of the encoder: It specifies the latitude position of the
encoder.
Height of the encoder: The height of the encoder from ground is
specified in this value.
Satellite Level: The level of each satellite signal received is shown in
this field.
Date: The updated date is shown.
#--º--.---´ ---k ---º
#---º--.---´ -----mt Satellite Level --/--/--
--:--:--
Level of the satellite signals Time
Date
Height (meters)
Speed(knot)/ Direction(degrees)
Longitude of the encoder
Latitude of the encoder
73 HEN-70_H.264 Encoder USER’S MANUAL V5.6
4.4 Application example Suppose it is wanted to know the constant positioning of the transmitter device. This is achievable with the next items:
- MOD-70 modulator
- HEN-70 encoder - GPS antenna - IRD-70 decoder
With the GPS antenna connected to the HEN-70, positioning of the device is
achieved once the GPS system is connected to the necessary satellites. Data obtained in the transmitter is the positioning of the device.
Next, this GPS data is sent to the MOD-70 through the ASI or TS over IP output and then, the modulator sends this data through the RF output until
it reaches the receiver system.
In the next page, a picture of this system is shown:
74 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Figure 4.4 GPS system example picture
MOD-70 modulator
IRD-70 GPS screen
IRD-70 Demodulator & Decoder
E20º45.512´ 10k47º1mt 04/10/13
N60º73.984´ S3 100km 100º 09:45:34
RS232 connection
PC with Google Earth
Video GPS
- Power Aplifier
- Up Converter
- Parabolic Antenna
Transmitter System
Receiver System
TS over IP
or ASI
HEN-70 encoder
75 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Chapter 5: Web Server
5.1 Introduction This equipment can be controlled by the use of a PC connected at the rear
panel Ethernet connector.
To enable the browser interface correctly, the IP address, Subnet Mask, Gateway, User Password and Administrator Password need to be set
correctly on this unit. Next, the steps so as to setup network parameters are shown:
1. Go to Unit -> Webserver & SNMP
Figure 5.1 Web Server screen
2. Select LOC option and set an IP address. So as to change the IP
address first press the OK button and then, with the Up, Down keys select the desired number. So as to change from one character to another, press Right, Left keys. Press the OK button so as to save the
introduced value.
Figure 5.2 Local IP
3. Select MSK option and set the Subnet Mask address. So as to change the Subnet Mask address first press the OK button and then, with the
Up, Down keys select the desired number. So as to change from one character to another, press Right, Left keys. Press the OK button so as to save the introduced value.
Figure 5.3 Subnet Mask
UNIT ETHERNET LOC 192.168.001.010
MSK 255.255.000.000 GAT 192.168.001.001
MAIN MENU Encoder IP Out
CA-BISS Unit
UNIT ETHERNET LOC 192.168.001.010
MSK 255.255.000.000 GAT 192.168.001.001
UNIT ETHERNET LOC 192.168.001.010
MSK 255.255.000.000 GAT 192.168.001.001
76 HEN-70_H.264 Encoder USER’S MANUAL V5.6
4. Select GAT option and set the Gateway address. So as to change the Gateway address first press the OK button and then, with the Up,
Down keys select the desired number. So as to change from one character to another, press Right, Left keys. Press the OK button so as to save the introduced value.
Figure 5.4 Gateway
5. Select Admin Pass option and set the administrator’s password. If it is
wanted to access to the Webserver directly without setting any
password, the Admin Pass must be set to 0 (00000000). However, if it is wanted to set an administrator’s password, it is necessary to
introduce 8 digits. In this way, with this password, the administrator can access to the Webserver and make any configuration, modification or monitoring.
Figure 5.5 Admin Pass
6. Select Restore Admin Pass option to restore de default value of the
administrator’s password.
Figure 5.6 Restore Admin Pass
7. Select User Pass option and set the user’s password. If it is wanted to access to the Webserver directly without setting any password, the User Pass must be set to 0 (00000000). However, if it is wanted to
set a user’s password, it is necessary to introduce 8 digits. In this way, with this password, the user can access to the Webserver and
make any monitoring.
UNIT ETHERNET
LOC 192.168.001.010 MSK 255.255.000.000
GAT 192.168.001.001
UNIT ETHERNET
70-B3-D5-1A-C0-00 Admin Pass: ********
Restore Admin Pas
UNIT ETHERNET
70-B3-D5-1A-C0-00 Admin Pass: ******** Restore Admin Pas
77 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Figure 5.7 User Pass
8. Select Restore User Pass option to restore de default value of the
administrator’s password.
Figure 5.8 Restore User Pass
Once the IP, Subnet Mask, Gateway, User Password and Admin Password are set and the laptop or PC is connected to the HEN-70, open the web browser and tip the IP given to the device.
Press enter button in your computer and then the main screen will appear.
5.2 Web Page Overview
The main menu is set in the upper position of the screen. Once an option is chosen, it is possible to change any parameter allowed or to see the values of some options.
In order to modify any parameter, introduce or select the new one and
press enter button. Then the change will be set in the encoder device. Next, several screens of the web server and their features are shown.
UNIT ETHERNET
User Pass: ******** Restore User Pas
UNIT ETHERNET User Pass: ********
Restore User Pas
78 HEN-70_H.264 Encoder USER’S MANUAL V5.6
5.2.1 ENCODER
Figure 5.9 Web Server Encoder screen
5.2.1.1 Video
- Input:
Select the type of the video input. The video input options available are SDI, HDMI, CVBS, ASI, IP and Test Pattern. (eligible parameter)
In case IP input is selected, the parameters related to this input can
be configured in the TSoIP screen.
- Format:
Here the format of the video input signal is displayed. If there is no video input then the message ‘not detected’ is displayed. (reading
parameter)
79 HEN-70_H.264 Encoder USER’S MANUAL V5.6
- Bitrate:
In this field the bitrate of the input signal in Mbps is displayed. (reading parameter)
- Delay:
In this field, the delay of the coding process is configured. The available options are Standard Delay, Low Delay, Super Low Delay or Ultra Low Delay. (eligible parameter)
- Profile:
In this field, the codification profile can be configured. The available
options are 4:2:0 and 4:2:2. (eligible parameter)
- GOP Size:
In this field, the group of figures parameter is displayed. It specifies
the order in which intra- and inter-frames are arranged. (eligible parameter)
The available options are:
Auto Manual (editable parameter)
Then the GOP size can be configured. The available options are (3, 6, 9, 12, 15, 18, 21, 24, 27, and 30).
5.2.1.2 Audio
- [A1] Input:
Select the type of signal introduced in the audio 1 input. The audio input options available are Embedded, Analogue, AES-EBU, Test Tone
Generator and None. (eligible parameter)
- [A1] Bitrate: Select the bitrate for the coding process of the audio 1 signal. The
available options are 128, 192, 256 and 384 Kbps. (eligible parameter)
- [A2] Input:
Select the type of signal introduced in the audio 2 input. The audio input options available are Embedded, Analogue, AES-EBU, Test Tone
Generator and None. (eligible parameter)
80 HEN-70_H.264 Encoder USER’S MANUAL V5.6
- [A2] Bitrate:
Select the bitrate for the coding process of the audio 2 signal. The available options are 128, 192, 256 and 384 Kbps. (eligible parameter)
5.2.1.3 Data
- Input:
Select the type of data introduced to the device. The available options are None, GPS and RS232. (eligible parameter)
5.2.1.3.1 RS-232
If it is wanted to send data to the device through a RS232 connection, this
option must be selected. It is also needed to configure the next parameters so as to achieve a successful communication:
- Baudrate:
Choose the baudrate of the RS-232 connection. The available options are 1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600. (eligible
parameter)
- Parity: Select the parity for the RS-232 connection. The available options are
None, ODD and Even. (eligible parameter)
- Stop Bits: Establish the number of stop bits for the RS-232 connection. The
available options are 1 and 2. (eligible parameter)
81 HEN-70_H.264 Encoder USER’S MANUAL V5.6
5.2.1.3.2 GPS
If GPS data is selected and the GPS antenna is connected to the device, then different parameters as shown in chapter 4 appear:
Figure 5.10 Web Server GPS screen
The format of the GPS coordinates used is decimal minutes as shown in the
next example:
N43º02.032’
W023º03.023’
- Status:
The status of the GPS input is displayed in this field. (reading parameter)
- Latitude:
It specifies the latitude position of the device. (reading parameter)
- Longitude: It specifies the longitude position of the device. (reading parameter)
- Altitude:
The height of the device from ground in meters is specified in this
value. (reading parameter)
- Direction:
The direction in degrees of the device is shown in this field. (reading
parameter)
82 HEN-70_H.264 Encoder USER’S MANUAL V5.6
- Speed:
The speed of the device in km/h is shown in this field. (reading parameter)
5.2.1.4 TS Parameters
- Video PID:
Here the video packet identifier must be entered. (editable parameter)
- Audio 1 PID:
Here the audio 1 packet identifier must be entered. (editable parameter)
- Audio 2 PID:
Here the audio 2 packet identifier must be entered. (editable parameter)
- Data PID:
Here the data packet identifier must be entered. (editable parameter)
- PMT PID:
Here the program map tables packet identifier must be entered. (editable parameter)
- PCR PID:
Here the program clock reference packet identifier must be entered. (editable parameter)
- Program Number:
Here the program number must be entered. (editable parameter)
- TS id:
In this field the Transport Stream identifier must be set. (editable
parameter)
- Network id:
In this option the network identifier must be specified. (editable
parameter)
83 HEN-70_H.264 Encoder USER’S MANUAL V5.6
- Network Name:
Specify the name of the network. (editable parameter)
- Service Name:
Set the name of the service. (editable parameter)
5.2.1.5 Output
- TS Bitrate: Select the desired bitrate (editable parameter)
When editable parameters are being set in the Web Server and new
values are being introduced, the text remains in red colour until the enter button is pressed. When the enter button is pressed, the new values are saved and the text will appear in black colour. It is
necessary to press the enter button to keep and save the new values on the screen.
84 HEN-70_H.264 Encoder USER’S MANUAL V5.6
5.2.2 TSoIP
Figure 5.11 Web Server TSoIP (IP Output) screen
- Local Address: Configure the IP address of the device which is going to send the
information. (editable parameter)
- Subnet:
Configure the Subnet address of the device which is going to send the information. (editable parameter)
- Gateway:
Configure the Gateway address of the device which is going to send the information. (editable parameter)
85 HEN-70_H.264 Encoder USER’S MANUAL V5.6
5.2.2.1 IP Output
- FEC:
In this field the Forward Error Correction can be enabled or disabled. In case it is enabled, the number of columns and rows can be configured. If FEC option is enabled then, the only protocol which can
be used is RTP. (eligible parameter)
- Destination address: In this option, the IP of the device to which data is sent must be
configured. In case it is wanted to send data to a multicast address just enter the desired multicast address. (editable parameter)
- UDP Port:
In this option, the IP of the device to which data is sent must be configured. (editable parameter)
- TP per IP:
In this field the number of Transport Stream packets per IP (from 1 to 7) can be configured. (editable parameter)
- Protocol:
In this field the type of protocol used for the communication is selected. The type of protocol used for the communication can be RTP
or UDP. (eligible parameter)
- Time To Live[0..255]: This field limits the lifetime of data. The Time to Live value (from 1 to
255) means the number of routers that a packet can reach until that packet is discarded. (editable parameter)
When editable parameters are being set in the Web Server and new
values are being introduced, the text remains in red colour until the
enter button is pressed. When the enter button is pressed, the new values are saved and the text will appear in black colour. It is
necessary to press the enter button to keep and save the new values on the screen.
86 HEN-70_H.264 Encoder USER’S MANUAL V5.6
5.2.2.2 IP Input
Figure 5.12 Web Server TSoIP (IP Input) screen
- Local Address: Configure the IP address of the device which is going to send the
information. (editable parameter)
- Subnet: Configure the Subnet address of the device which is going to send the
information. (editable parameter)
- Gateway: Configure the Gateway address of the device which is going to send
the information. (editable parameter)
87 HEN-70_H.264 Encoder USER’S MANUAL V5.6
5.2.2.3 IP Input
- Addressing:
In this field it is configured if the IP received packets come from a unicast address or from a multicast address. (eligible parameter)
- Multicast address:
In this field the multicast address must be specified so as to receive the information properly. (editable parameter)
- FEC:
In this option the FEC option can be enabled or disabled. In case the enable option is selected, as the IP Forward Error Correction is
composed by a number of FEC columns and rows, it is shown the number of FEC columns and rows of the received signal. (eligible
parameter)
- UDP Port:
This field must be filled in with the port number of the device through
which is going to receive the signal. (editable parameter)
- Output Delay:
This delay means the time passed between the Transport Stream is
obtained in the decoder and the signal is taken out from the decoder. (editable parameter)
- Status:
In this field the status of the IP input is displayed. (reading parameter)
- BitRate:
In this field, the bitrate of the received signal is shown. (reading parameter)
- Packet Size:
In this field, the size in bytes of the IP received packet is displayed. (reading parameter)
- TP per IP:
In this option the number of Transport Stream packets per IP packet is displayed. (reading parameter)
88 HEN-70_H.264 Encoder USER’S MANUAL V5.6
- Protocol:
In this field the protocol used for the communication is displayed. Two protocols are possible: UDP or RTP. (reading parameter)
- PCR Present: Program Clock Reference. To enable a decoder to present
synchronized content, such as audio tracks matching the associated video, at least once each 100 ms a Program Clock Reference, or PCR is transmitted in the adaptation field of an MPEG-2 transport stream
packet. The parameters displayed can be present or no present. (reading parameter)
When editable parameters are being set in the Web Server and new
values are being introduced, the text remains in red colour until the
enter button is pressed. When the enter button is pressed, the new values are saved and the text will appear in black colour. It is
necessary to press the enter button to keep and save the new values on the screen.
89 HEN-70_H.264 Encoder USER’S MANUAL V5.6
5.2.3 CA-BISS
Figure 5.13 Web Server CA-BISS screen
- BISS Mode:
Select the BISS encryption mode. (eligible parameter)
- Session Word:
Key for BISS-1 and BISS-E. The values of each characer introduced
can be from 0 to 9 and from A to F. (editable parameter)
- User ID:
User ID for BISS-E. The values of each characer introduced can be
from 0 to 9 and from A to F. (editable parameter)
When editable parameters are being set in the Web Server and new
values are being introduced, the text remains in red colour until the enter button is pressed. When the enter button is pressed, the new
values are saved and the text will appear in black colour. It is necessary to press the enter button to keep and save the new values on the screen.
90 HEN-70_H.264 Encoder USER’S MANUAL V5.6
5.2.4 UNIT
Figure 5.14 Web Server UNIT screen
5.2.4.1 LEDs Status (reading parameters)
- ON/OFF:
o If the Led is off the equipment is not being fed.
o The Led lights up in green when the equipment is turned on.
- ALARM:
o The LED lights up in red when any alarm occurs.
o The different alarms that can appear are: Voltage High.
Voltage Low. Temperature High.
91 HEN-70_H.264 Encoder USER’S MANUAL V5.6
o The different warnings that can appear are: No Video Input.
No GPS.
- STATUS:
The LED lights up when a change in the configuration of the device is
being processed.
5.2.4.2 Alarms (reading parameter)
In this option, different alarms which are present in the device are shown. The different alarms that can appear are:
- Voltage High. - Voltage Low.
- Temperature High. The different warnings that can appear are:
- No Video Input. - No GPS.
5.2.4.3 Configuration
- Web&SNMP Address
In this option it can be set the IP address of the device in case it is wanted to control the device remotely. So as to change the IP
address, introduce the desired number and then press enter button to save the introduced value. (editable parameter)
- Web&SNMP Subnet
Here, the Subnet Mask address of the device can be written. So as to change the Subnet Mask address, introduce the desired value and
then press enter button to save it. (editable parameter)
- Web&SNMP Gateway
In this option, the address of the Gateway must be written. So as to
change the Gateway address, introduce the desired value and then press enter button to save it. (editable parameter)
- Web&SNMP MAC
In this option the MAC address of the device is shown. (reading parameter)
92 HEN-70_H.264 Encoder USER’S MANUAL V5.6
- Standby Mode
In this option the user can turn on or turn off the device pressing On or Standby options. (elegible parameters)
- Night Mode:
If the night mode is OFF then, the light in the screen will shine more than if the night mode is ON. (eligible parameter)
- Admin Password
In this field, the administrator’s password is introduced. It can be set an own password which is a list of 8 digits. Then, to save the
introduced value, press Enter button. Moreover, there is the option to restore the default administrator password (00000000). (editable parameter)
- User Password
In this field, the user’s password is introduced. It can be set an own password which is a list of 8 digits. Then, to save the introduced
value, press Enter button. Moreover, there is the option to restore the default user password (00000000). (editable parameter)
5.2.4.4 Monitor
- Voltage:
In this field, the voltage of the device is shown. (reading parameter)
- Temperature:
In this field, the internal temperature of the device is displayed. (reading parameter)
- S/N:
In this field, the serial number of the device is displayed. (reading parameter)
- Firmware:
In this field, the number of the version installed in the device is displayed. (reading parameter)
- Model:
In this field, the model of the device is displayed. (reading parameter)
93 HEN-70_H.264 Encoder USER’S MANUAL V5.6
When editable parameters are being set in the Web Server and new
values are being introduced, the text remains in red colour until the
enter button is pressed. When the enter button is pressed, the new values are saved and the text will appear in black colour. It is necessary to press the enter button to keep and save the new values
on the screen.
94 HEN-70_H.264 Encoder USER’S MANUAL V5.6
5.3 Web Page Setup Notes In order for the data to be refreshed correctly, you may need to change some settings on your browser.
Please follow these instructions carefully.
For Google Chrome:
1. Make click in the Chrome menu situated in the toolbar of the browser.
2. Select tools. 3. Choose the option Delete navigation data… 4. Choose the option empty cache.
5. Make click in Delete navigation data.
For Internet Explorer:
1. From the Tools menu, select Internet Options 2. In the General tab, click the Settings button in the Browsing History section.
3. Select 'Every time I visit the webpage' then click the OK button. 4. Click the OK button
For Mozilla Firefox:
1. Open a new tab, in the address bar enter about:config 2. In the Filter box, enter disk
3. Set the value for 'browser.cache.disk.enable' to false (double click to change the setting). 4. Close the about:config tab.
5.4 SNMP Simple Network Management Protocol (SNMP) is an "Internet-standard protocol for managing devices on IP networks. SNMP exposes management
data in the form of variables on the managed systems, which describe the system configuration. These variables can then be queried (and sometimes
set) by managing applications. SNMP is an application-layer protocol and it runs over UDP at the transport
level. SNMP is based on a manager / agent model as it is shown below:
95 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Figure 5.15 SNMP management system
The SNMP agent used is MIB-II compliant. The SVP MIB (Management
Information Database) provides a standard representation of the SNMP Agent’s available information and where it is stored. The MIB is defined according to the ASN.1.
5.4.1 SNMP commands
SNMP use the next commands:
Operation Description Sender
Get
Readout the current value
of specific objects in the
MIB.
NMS
Get next
Readout the current value
of the next object in the
MIB.
NMS
Set
Change a value of a
specific object in the MIB.
NMS
Get response
Responds to a get, get
next or set request.
Agent
Trap
A trap is a mechanism to
trigger the NMS that a
change in the device has
occurred.
After receiving the trap
the NMS still has to poll
the device to find out the
details of the change.
Agent
Table 5.1 SNMP commands
Network Management Station SNMP agent
96 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Chapter 6: Equipment Installation
6.1 Introduction This chapter provides important information for encoder system installation such as connections available in the rear panel of the HEN-70 encoder and
their pinout, connectors needed and the accessories which are available with the encoder device.
6.2 Connections Every connection of the HEN-70 encoder is on the rear panel.
All the Lemo part numbers and pinout refer to the connector that is fixed to
the cable. The pinout of the cable connector is shown as if it is watched
from the soldering side.
All the input/output connections of the encoder are shown in the figure below:
Figure 6.1 HEN-70 Connections
The following figures show the HEN-70 front and rear panel. Connections mentioned in the upper figure are shown below.
Figure 6.2 HEN-70 front panel
HEN-70 Encoder
SDI (3G/SD/HD)
HDMI
Ethernet
Audio 1 (L&R)
Audio 2 (L&R)
TS over IP OUT
Power DC & AC
USB
DATA/GPS
ASI OUT AES/ABU
TS over IP IN
ASI IN
CVBS
97 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Figure 6.3 HEN-70 rear panel
The technical features of each connection are described on the following
sections.
98 HEN-70_H.264 Encoder USER’S MANUAL V5.6
6.2.1 Power supply
In this section, technical features about the power supply connections available and the connectors needed are described.
In all the Lemo connectors, the pin number one is circled and the
succeeding pins are in counter clockwise order.
AC Power supply
The encoder equipment can be powered by an AC source between 100 and 240V, or a DC source from 8 to 36 V.
The main frequency should be between 50 and 60 Hz.
The AC mains input uses a Neutrik MLC connector. A cable with the required connectors is supplied with the equipment. The AC power connector used in
this equipment is designed to prevent accidental disconnection. To extract the connector, pull back the locking clip and rotate the connector, as
indicated on the connector itself.
Power supply AC connection technical features
Item Features
Connector label POWER A.C.
Connector type MLC Neutrik
Supply voltage 100-240 V. (50/60Hz)
Table 6.1 AC Power supply features
Pinout
99 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Pin Description
1 L
2 GND
3 N
Table 6.2 AC Power supply connector pinout
Connector needed
DC Power supply
The encoder equipment can be powered by a DC source from 8 to 36 V. The DC power supply is connected via a Neutrik 4-pin male XLR connector
with a safety clip to prevent accidental disconnection.
Power supply DC connection technical features
Item Features
Connector label POWER D.C.
Conector type XLR-4 male
Supply voltage 8-36 V.
Table 6.3 DC Power supply features
NAC3FCA
NAC3MPA
100 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Pinout
Pin Description
1 GND
2 GND
3 VCC
4 VCC
Table 6.4 DC Power supply connector pinout
Connector needed
The DC power supply is connected via a Neutrik 4-pin male XLR connector with a safety clip to prevent accidental disconnection.
101 HEN-70_H.264 Encoder USER’S MANUAL V5.6
6.2.2 ASI
ASI input
The HEN-70 encoder has a DVB-ASI Transport Stream input, available on
an insulated 75 Ω BNC connector.
ASI IN connection technical features
Item Features
Connector label ASI-IN
Connector type Female BNC
Impedance 75 Ω
Standard EN50083-9
Maximum Bitrate 216 Mbps
Table 6.5 DVB-ASI Transport Stream input connection features
ASI output
ASI output signal type uses 75Ω BNC connector. This connector is placed on the HEN-70 encoder rear panel.
It is important that 75 Ω connectors are used. This is because the female
output connector of the HEN-70 unit may be damaged and because of an impedance mismatch.
ASI connection technical features
Item Features
Connector label ASI-OUT
Connector type BNC female
Impedance 75 Ω
Standard EN50083-9
Maximum Bitrate 100 Mbit/s
Table 6.6 DVB-ASI Transport Stream output connection features
102 HEN-70_H.264 Encoder USER’S MANUAL V5.6
6.2.3 CVBS/ SDI/ HDMI
The HEN-70 encoder and modulator incorporates an HDMI input so as to allow that new devices can be connected.
SD-SDI digital video input is compatible with SMPTE-259 Standard, HD-SDI digital video input signal type is SMPTE-292 compliant and 3G-SDI digital
video input signal type is SMPTE-425M compliant. In chapter 3: HEN-70 Menus and Operation, it is explained in detail how to
choose the input video signal type, CVBS, HDMI, digital video SDI signal or DVB-ASI Transport Stream signal.
CVBS connection technical features
Item Features
Connector Label CVBS
Connector type Female BNC
Impedance 75 Ω
Table 6.7 CVBS signal connection features
SDI connection technical features
Item Features
Connector Label SDI
Connector type Female BNC
Impedance 75 Ω
Input Level 800 mVpp nominal ±10%
Standards SMPTE-259M and SMPTE-272M
SMPTE-292M and SMPTE-299M
SMPTE-425M
Bitrate SD: 270 Mbit/s
HD: 1485 Mbit/s
3G: 3 Gbit/s
Table 6.8 SDI input signal connection features
HDMI connection technical features
Item Features
Connector Label HDMI
Connector type Type A
Table 6.9 HDMI input signal connection features
103 HEN-70_H.264 Encoder USER’S MANUAL V5.6
6.2.4 Transport Stream over IP
Transport Stream over IP Input and Output
The HEN-70 encoder has a connector that allows receiving and transporting video over IP. The connector is an UTP Cat 5e which is described in the
EIA/TIA568B standard.
TS over IP connection technical features
Item Features
Connector Label VIDEO over IP
Connector type RJ-45
Table 6.10 Transport stream over IP input connection technical features
There is no recompression when the equipment sends the information through IP. At the level of ASI and IP, the device keeps the original coding
generated in the transmitter.
Transport Stream over IP gives some benefits like:
Ensured Quality of Service with highly reliable Video Gateways.
Built-in intelligent monitoring and redundancy solutions.
Simple and fast connection setup and teardown with T-VIPS Connect.
Allows broadcasters and network operators to simplify their day to day
operation.
Create revenue-generating professional Wide Area Networks for video
transport.
Technical features are described below:
IP encapsulation and 2D FEC encoding and decoding as defined in SMPTE 2022.
Persistent storage of configuration parameters. Unicast and multicast IP addressing.
It is not possible to configure the equipment as IP input and IP output at
the same time.
104 HEN-70_H.264 Encoder USER’S MANUAL V5.6
6.2.5 Audio inputs
The HEN-70 encoder has four possible audio inputs:
2 audio inputs to insert 2 AES/EBU stereo channels, 2 stereo or 4
mono analogue (mic phantom, mic dynamic and line) signals where connections are made using two 5 pin Lemo 0B connectors on
equipment rear panel.
1 input to insert either 4 audio channels embedded on a SDI signal
where connections are made with a BNC connector on equipment rear panel.
1 HDMI input to insert HDMI embedded audio signals where
connections are made with a HDMI connector on equipment rear panel.
Embedded audio signals must be compliant with SMPTE-272M standard
when embedded on SD-SDI video signal, SMPTE-299M standard when embedded on HD-SDI video signal and with SMPTE-424 when embedded on 3G-SDI signal.
AES/EBU and analogue audio input technical features
Item Features
Audio channel number 4
Connector labels AUDIO 1
AUDIO 2
Connector type 5 pin Lemo 0B
Cable connector part number FGG.0B.305.CLAZ
Manufacturer Lemo
Table 6.11 AES/EBU and analogue audio input connection technical features
105 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Pinout of the cable connector (Watched from the soldering side)
Pin Description
1 A1L+ / AES1
2 A1L- / AES1N
3 GND
4 A1R+
5 A1R-
Table 6.12 AES/EBU and analogue audio cable connector pinout
2 5
3 4
1
106 HEN-70_H.264 Encoder USER’S MANUAL V5.6
6.2.6 Data/GPS input
This input is mainly used in order to transfer GPS data or user data through connections made using 6 pin Lemo 0B connector on equipment rear panel. Thanks to this characteristic it is possible to obtain GPS coordinates in the
HEN-70 encoder, know the exact position of the encoder and the distance between the receiver and the encoder as well as other parameters.
Data/GPS connection technical features
Item Features
Connector Label Data/GPS
Connector type 6 pin Lemo 0B
Cable connector part number FGG.0B.306.CLAZ
Manufacturer Lemo
Table 6.13 Data/GPS input connection technical features
Pinout of the cable connector (Watched from the soldering side)
Pin Description
1 Ground
2 DATA
3 NOT USED
4 +5Vd_GPS
5 PA_ON/OFF
6 PA_DIRECT
Table 6.14 Data/GPS cable connector pinout
1
3
2
4
5
6
107 HEN-70_H.264 Encoder USER’S MANUAL V5.6
6.2.7 USB connection
Thanks to the USB connection, it is possible to update directly from an external USB device the firmware of the HEN-70 encoder. The connector is type A.
USB connection technical features
Item Features
Connector Label USB
Connector type Type A
Table 6.15 USB connection technical features
6.2.8 Ethernet
This connection allows the user to monitor and setup any parameter of the
encoder throughout Web Browser and SNMP through the network. The connector used is a RJ-45.
Ethernet connection technical features
Item Features
Connector Label Ethernet
Connector type RJ-45
Table 6.16 Ethernet input connection technical features
108 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Glossary
AES/EBU
Audio Engineering Society/European
Broadcasting Union
ACPR
Adjacent Channel Power Ratio
APSK
Amplitude and phase-shift keying or asymmetric phase-shift
keying (APSK)
ASI
Asynchronous Serial Interface
BNC
Bayonet Neill-Concelman
BR
BitRate
CA-BISS
Conditional Access-BISS
COFDM
Coded Orthogonal Frequency
Division Multiplexing
DC
Direct current
DVB-S2
Digital Video Broadcasting by
Satellite – Second Generation
DVB-T
Digital Video Broadcasting –
Terrestrial
DVB-T2
Digital Video Broadcasting –
Terrestrial Second Generation
ETSI
European Telecommunications Standards Institute
109 HEN-70_H.264 Encoder USER’S MANUAL V5.6
EVM
Error Vector Magnitude
FEC
Forward Error Correction
FFT
Fast Fourier transform
GPS
Global Positioning System
HD
High Definition
HDMI
High-Definition Multimedia Interface
HDR
High Definition Receiver
HDT
High Definition Transmitter
IF
Intermediate Frequency
IG
Interval Guard
IP
Internet Protocol
LCD
Liquid Crystal Display
LED
Light-Emitting Diode
LD
Low Delay
MPEG
Moving Picture Experts Group
NLOS
Non Line of Sight
110 HEN-70_H.264 Encoder USER’S MANUAL V5.6
PAL PAL
PID
Packet Identification
QAM
Quadrature Amplitude Modulation
QPSK
Quadrature Phase-Shift Keying
RF
RadioFrequency
RTC
Remote Control
SD
Standard Delay
SDI
Serial Digital Interface
SNMP
Simple Network Management
Protocol
TFT
Thin-Film Transistor
TS
Transport Stream
UDP
User Datagram Protocol
USB
Universal Serial Bus
112 HEN-70_H.264 Encoder USER’S MANUAL V5.6
Final note
SVP Broadcast Microwave S.L. is constantly striving to improve all of its products.
Therefore, we ask you to understand that modifications may occur in
designs, equipment and technology. Consequently, no responsibility can be derived from the information, illustrations or descriptions contained in this manual.
The texts, illustrations and instructions in the manual are based on the
existing situation when the manual is published.
Reprinting, reproduction and translation, in part or in whole,
is forbidden without written authorisation from SVP Broadcast
Microwave S.L. SVP Broadcast Microwave reserves all rights regarding intellectual property
rights.
All rights reserved regarding modifications.
SVP Broadcast Microwave reserves the right to make changes to this manual and to the equipment without prior notice.
C/ Zubiaurre 7 bajo
48215 Iurreta Vizcaya – Spain
Tel: (+34) 94620 3722
[email protected] www.svpbm.com