H.264 ENCODER HEN-70 USER MANUAL V5.6 - SVP Aerospace

114
H.264 ENCODER HEN-70 USER MANUAL V5.6

Transcript of H.264 ENCODER HEN-70 USER MANUAL V5.6 - SVP Aerospace

H.264 ENCODER

HEN-70

USER MANUAL V5.6

I HEN-70_H.264 Encoder USER’S MANUAL V5.6

Contents

Chapter 1: Introduction This first chapter provides a general description of the High Definition HEN-70 encoder.

Chapter 2: Technical features

This second part offers a detailed description of the HEN-70 encoder’s physical and environmental characteristics.

Chapter 3: Encoder operation and Menus This third part provides the user all the necessary information to control and operate the equipment properly. It is detailed the function of each button on

the keyboard. It is also explained how the information is shown on the display, encoder menus, etc.

Chapter 4: GPS Application In this chapter, the use of the GPS incorporated system and some of its

applications are shown.

Chapter 5: Web Server

This chapter provides a detailed description of the Web Server tool. This

feature allows controlling the HEN-70 encoder through a website.

Chapter 6: Equipment Installation

This chapter indicates the available connections of the encoder, their characteristics and the installation of the encoder.

II HEN-70_H.264 Encoder USER’S MANUAL V5.6

Dear customer,

We would like to thank you for selecting this equipment and welcome you to the SVP’s growing family of products.

We are sure that the addition of this equipment will cause you a complete satisfaction in your existing installation.

Please read these instructions carefully, and keep them in hand in case you have to refer to them.

III HEN-70_H.264 Encoder USER’S MANUAL V5.6

About this manual

This user’s guide provides indications and explanations about how to set up the HEN-70 encoder easily for the most common use cases.

This document is intended to help first time users:

- To find their way around the GUI.

- To understand the different possibilities of the HEN-70 encoder.

- To configure the HEN-70 for their specific configurations.

Symbols

The symbols that appear in this manual are:

An information message which indicates explanations for the

proper operation of the equipment.

It advises users that if they do not take, avoid or make specific

actions, several damages could appear in the device.

In the places where this symbol appears it means that by

pressing the Down button of the equipment the user can

access to the next screen.

This symbol means that pressing the OK button in the options

where this symbol appear, the user can access to the submenu

related to that option or can change the value of the

parameter.

<> These symbols mean that the parameter can be modified in the same screen with the right and left keys.

IV HEN-70_H.264 Encoder USER’S MANUAL V5.6

Important Notes

1. The HEN-70 encoder applies an MPEG-4 compression to either HDMI,

composite video, SD-SDI or HD-SDI input signals. An MPEG-1 layer 2

compression is applied to the corresponding 2 analogue audio channels, the 2 stereo SDI embedded, the HDMI embedded and the AES digital

audio signals. 2. Special care should be taken with SDI cables, quality and length, these

are very important, especially when HD-SDI or 3G-SDI signals are transmitted.

3. This device has the ASI and IP output available when the input is ASI.

Besides, it also has the ASI output available when the input is IP.

4. In 1080p Video Format, it can only be performed the Standard Delay,

not the Low Delay, the Super Low Delay or the Ultra Low Delay.

5. In case it is selected SDI input with 1080p format, the delay will be automatically Standard.

6. If any audio or data channel are not used in a transmission, they should be disabled, in order to assign that bitrate to the video and achieve a

higher quality transmitted video signal. 7. Only authorized personnel should open the product and any repair or

warranty will be invalidated if the seals are broken.

V HEN-70_H.264 Encoder USER’S MANUAL V5.6

First Aid in Case of Electric Shock

DO NOT TOUCH THE VICTIM WITH YOUR BARE HANDS until the circuit is broken. SWITCH OFF. If this is not possible, PROTECT YOURSELF with DRY

insulating material and pull the victim clear of the conductor.

If breathing has stopped, indicated by unconsciousness, lack of respiratory movements and a ‘blue’ look to cheeks, lips, ears and nails, START RESUSCITATION AT ONCE.

EMERGENCY RESUSCITATION – THE EXPIRED AIR METHOD

(Approved by the Royal Life Saving Society)

1. If possible, lie the victim on his back with his head slightly higher

than his feet. Clear the mouth and throat of any obvious obstruction.

2. Kneel on one side of the victim, level with his head. LIFT THE JAW AND TILT THE HEAD BACK AS FAR AS POSSIBLE (Figs. 1a and 1b)

3. One of the following may happen: a) Breathing may begin and consciousness return.

b) Breathing may begin but consciousness NOT return. Turn the victim on his side and ensure

that the airway is kept clear. c) Breathing may return but be NOISY which

means that the airway is not fully clear. Try to

clear the airway.

4. IF THERE NO SIGN OF BREATHING: a) Check that the head is still tilted back. b) Take a deep breath.

c) Pinch the victim’s nose and blow firmly into his mouth (Fig. 2). As you do, the chest will RISE.

d) Turn your head away and take another breath, watching for the chest to FALL (Fig. 3).

5. Start with four quick breaths and then continue with one breath every five seconds (i.e. 12 times a

minute). This should be continued until the victim revives or a doctor certifies death.

6. As consciousness returns the victim will start to breathe on his own, and a ‘pink’ color replaces the

‘blue’ look: this is the time to stop resuscitation. Continue to hold his chin up and so keep the airway clear.

7. In the case of injuries to the mouth, it may be necessary to use

mouth-to-nose resuscitation. Seal the victim’s mouth with your cheek and blow firmly into his nose, proceeding as above.

VI HEN-70_H.264 Encoder USER’S MANUAL V5.6

8. In the case of severe facial injuries it may be necessary to do a manual method of artificial respiration (Silvester-Brosch or Holger

Nielsen). Briefly, these methods apply compression to ribcage with the victim lying on his back (S-B) or face down (H.N.) with associated movement of his arms up and out. The cycle of movement should

take about five seconds, i.e. the normal breathing phase.

9. Whatever the method, it is ESSENTIAL to commence resuscitation WITHOUT DELAY and to send for medical assistance immediately.

TREATMENT FOR BURNS

If the victim is also suffering from burns, then, without hindrance to resuscitation, observe the following:

a) DO NOT ATTEMP TO REMOVE CLOTHING ADHERING TO THE BURN.

b) If possible alleviate the pain from the burnt part by immersing in cold water.

c) If help as available or as soon as resuscitation is no longer required

the wound should be covered with a DRY clean dressing.

d) Oil or grease in any form should not be applied.

e) If severely burnt, get the victim to hospital immediately.

7 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Main Index

Chapter 1: Introduction ....................................................................... 9

Chapter 2: Technical Features ............................................................. 10

Chapter 3: Encoder Operation and Menus ............................................. 13

3.1 Display .................................................................................. 13

3.2 LEDs ..................................................................................... 16

3.3 Front panel ............................................................................ 17

3.3.1 ON/OFF Button ................................................................. 17 3.3.2 OK Button ........................................................................ 18 3.3.3 Cross Button .................................................................... 18 3.3.4 Left and Right Button ........................................................ 19 3.3.5 Up and Down Button ......................................................... 19

3.4 Menus ................................................................................... 20

3.4.1 Menu Navigation ............................................................... 25 3.4.2 Menu Structure ................................................................. 26

3.4.2.1 Encoder Menu ............................................................. 27 3.4.2.1.1 SDI Input .............................................................. 29 3.4.2.1.2 HDMI Input ........................................................... 31 3.4.2.1.3 CVBS Input ........................................................... 33 3.4.2.1.4 ASI Input .............................................................. 35 3.4.2.1.5 IP Input ................................................................ 36 3.4.2.1.6 Generator Input ..................................................... 40 3.4.2.1.7 Audio1 Embedded .................................................. 41 3.4.2.1.8 Audio1 Analogue .................................................... 42 3.4.2.1.9 Audio1 AES-EBU .................................................... 43 3.4.2.1.10 Audio1 Tone.Gen ................................................. 44 3.4.2.1.11 Audio2 Embedded ................................................ 45 3.4.2.1.12 Audio2 Analogue .................................................. 46 3.4.2.1.13 Audio2 AES-EBU .................................................. 47 3.4.2.1.14 Audio2 Tone.Gen ................................................. 48 3.4.2.1.15 Data ................................................................... 49 3.4.2.1.16 Encoder Output ................................................... 52 3.4.2.1.17 TS Parameters ..................................................... 53

3.4.2.2 CA-BISS Menu ............................................................ 56 3.4.2.3 IP Out ........................................................................ 58 3.4.2.4 Unit Menu ................................................................... 60

3.4.2.4.1 Alarms .................................................................. 60 3.4.2.4.2 Monitor ................................................................. 61 3.4.2.4.3 Webserver & SNMP ................................................ 62 3.4.2.4.4 Miscellaneous ........................................................ 64 3.4.2.4.5 Firmware .............................................................. 66 3.4.2.4.6 BUC S/S2 Unit ....................................................... 70

Chapter 4: GPS Application ................................................................. 71

8 HEN-70_H.264 Encoder USER’S MANUAL V5.6

4.1 Introduction ........................................................................... 71

4.2 Main Screen ........................................................................... 71

4.3 GPS encoder screen ................................................................ 72

4.4 Application example ................................................................ 73

Chapter 5: Web Server ....................................................................... 75

5.1 Introduction ........................................................................... 75

5.2 Web Page Overview ................................................................ 77

5.2.1 ENCODER ......................................................................... 78 5.2.1.1 Video ......................................................................... 78 5.2.1.2 Audio ......................................................................... 79 5.2.1.3 Data .......................................................................... 80

5.2.1.3.1 RS-232 ................................................................. 80 5.2.1.3.2 GPS...................................................................... 81

5.2.1.4 TS Parameters ............................................................ 82 5.2.1.5 Output ....................................................................... 83

5.2.2 TSoIP .............................................................................. 84 5.2.2.1 IP Output ................................................................... 85 5.2.2.2 IP Input ..................................................................... 86 5.2.2.3 IP Input ..................................................................... 87

5.2.3 CA-BISS .......................................................................... 89 5.2.4 UNIT ............................................................................... 90

5.2.4.1 LEDs Status (reading parameters) ................................. 90 5.2.4.2 Alarms (reading parameter) .......................................... 91 5.2.4.3 Configuration .............................................................. 91 5.2.4.4 Monitor ...................................................................... 92

5.3 Web Page Setup Notes ............................................................ 94

5.4 SNMP .................................................................................... 94

5.4.1 SNMP commands .............................................................. 95 Chapter 6: Equipment Installation ....................................................... 96

6.1 Introduction ........................................................................... 96

6.2 Connections ........................................................................... 96

6.2.1 Power supply .................................................................... 98 AC Power supply ....................................................................... 98 DC Power supply ....................................................................... 99

6.2.2 ASI ............................................................................... 101 ASI input ................................................................................ 101 ASI output .............................................................................. 101

6.2.3 CVBS/ SDI/ HDMI ........................................................... 102 6.2.4 Transport Stream over IP ................................................. 103

Transport Stream over IP Input and Output ................................ 103 6.2.5 Audio inputs ................................................................... 104 6.2.6 Data/GPS input ............................................................... 106 6.2.7 USB connection .............................................................. 107 6.2.8 Ethernet ........................................................................ 107

9 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Chapter 1: Introduction

The HEN-70 is the new encoder developed by SVP Broadcast Microwave. SVP has reached the state of the art with this encoder, so it is ideal for

portable use when the highest quality available on the market is required. This device is a H.264 encoder, which can work with SD and HD input

signals, being able to detect automatically the video input format. For added security, the signal can be encrypted using the BISS encryption technology.

This encoder has several analogue and digital video interfaces (3G-SDI, HD-

SDI, SD-SDI, HDMI and CVBS) as well as several audio interfaces (SDI embedded, AES digital, HDMI embedded and Analogue).

The HEN-70 also provides a network interface for Transport Stream over IP based networks as well as ASI output. It allows sending the signals over IP

based networks. It allows the remote control of block up-converters for satellite applications.

The small size and lightweight make the HEN-70 encoder the suitable

equipment to be used in broadcast and professional applications, such as satellite uplinks, point-to-point radio links and many other uses.

10 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Chapter 2: Technical Features

Encoder

Video compression: H.264/MPEG-4 Part 10

Profile: High 422, High, Main

Level: 3.0/3.1/3.2/4.0/4.1

Latency: Ultra Low delay: 33 ms Audio compression: MPEG-1 Layer II

Audio bit rate: 128, 192, 256 or 384 Kbps

Output bit rate: 1 Mbps – 100 Mbps

Encryption

BISS: BISS-1 and BISS-E

AES: AES-128 and AES-256 (Optional)

Video: Inputs: 3G-SDI SMPTE-425M-A(299M)

HD-SDI SMPTE-292M(299M) SD-SDI SMPTE-259M(272M)

HDMI (1.4a) Composite video (PAL/NTSC)

Formats: 1080p (1920x1080) – 23.98/24/25/ 29.97/30/50/59.94/60 Hz

1080i (1920x1080) – 50/59.94/60 Hz 720p (1280x720) – 23.98/24/25/29.97/ 30/50/59.94/60 Hz

576i (720x576) – 50 Hz 480i (720x480) – 59.94 Hz

11 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Audio:

Input: SDI embedded / HDMI embedded

AES Digital / Analogue Analogue: 2 Stereo / 4 Mono

Line, Micro Dynamic and Micro with Phantom

SDI embedded: 1 Group (4 audio channels)

AES/EBU: 2 Stereo channels

Data Channels

Data channel: User data or GPS

Data rate: 1.200 to 57.600 bps

Test Signals

Video: Bars with moving icon

Audio: 4 Audio tones

ASI and IP

Input and Output: ASI Transport Stream (EN50083-9) Transport Stream over IP (SMPTE2022/CoP3) - FEC

188/204 byte-packets Max. TS packets / IP packet: 7

Control & Monitorization

Control Interfaces: Front panel & display

Web Server SNMP RTC-01 via cable

Monitoring: Encoding parameters

Status Alarms and warnings.

12 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Power Supply

AC input: 100 to 240V

DC input: 8 to 36 V

Consumption: <20W

Mechanical

Size: 1/2 RU, 210 x 44 x 240 mm (WxHxD)

Weight: 1,8 Kg

Environmental

Temperature range: -10 to 45 ºC

Height: 4.500 m Humidity: 95%

13 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Chapter 3: Encoder Operation and Menus This third chapter provides the user all the necessary information to control,

configure and operate the equipment properly.

3.1 Display

To switch the equipment on and off, press the ON/OFF button. When the equipment is turned on, the display will show the start-up message (model

and version of the equipment) for two seconds. When a video, audio or data input has been selected, a character connected

to this input is displayed in the main screen.

Next, the main screen of the HEN-70 encoder is shown.

Figure 3.1 HEN-70 front panel/ Main screen explanation

ENCODER HEN-70 Bitrate: 30.0 Mbps

239.192.000.001:5678 GAEX 576/50i 420S XXX/XX

Video Input Selection

Audio Input Selection

Data Input Selection

FEC

Input Video Signal Format

Bitrate

Latency

Encoder Video Profile

IP Port

14 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Once an option has been selected, the main screen appears and these parameters are displayed:

Transmitted bitrate (Mbps). IP address.

Port number. Video input selection

- Possibilities: CVBS, HDMI, SDI, DVB-ASI Transport Stream or Generator.

- Behaviour of the corresponding character: If the character is

static then it means presence of that signal. If the character is blinking then it means absence of that signal.

Audio status indication: If audio 1 or 2 is not darkened then it is

enabled. On the other hand, if audio 1 or 2 is darkened then it is disabled.

Data status indication: If this field is not darkened then it means that

data is enabled. On the other hand, if this value is darkened it means that data is disabled. Moreover, in case this field is static, its meaning is

presence of the data whereas if this field is blinking, it means absence of the data.

Input video signal format.

Encoder Video Profile (4.2.0 or 4.2.2). Latency (Standard delay, Low delay, Super Low Delay or Ultra Low

Delay) - Standard Delay (Lipsync < 10 ms) - Low delay (Lipsync < 10 ms) 3 frame

- Super Low Delay (Lipsync < 10 ms) 2 frame - Ultra Low Delay (Lipsync = 20 ms) 1 frame

15 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Next, the linkages between the input and the character displayed in the principal screen are shown:

Video

CVBS

C

HDMI

H

SDI

S

ASI

ASI

IP

I

Test Pattern

G

Audio

Embedded

E

AES/EBU

U

Analogue

A

Test Tone

G

Data

RS232

D

GPS

G

Table 3.1 Linkages between the input and the character displayed

16 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.2 LEDs

The HEN-70 encoder has 4 Leds on its front panel that show the information detailed below.

The ON/OFF provides the following information:

If the Led is off, the equipment is not being fed. If the Led flickers in red, there is power into the equipment but it is

turned off. The Led lights up in green when the equipment is turned on.

The ALARM LED provides the following information:

The LED lights up in red when any alarm occurs. The different alarms that can appear in the transmitter are:

- Voltage High or Low.

- Temperature High. - ASI Overflow: This alarm means that the input bitrate is higher than

the one that can be modulated due to the parameters configured

(constellation, FEC, GI...).

The different warnings that can appear in the transmitter are:

- No Video Input.

- No GPS.

The HPA ALARM LED provides the following information: The LED lights up in green when a BUC is connected to the HDT-70. It is

used in satellite transmission standards.

The STATUS LED: The LED lights up when a change in the configuration of the device is

being processed.

MOD LED and CARRIER LED: These LEDs light up when DVB-S2 transmission standard is being used.

Figure 3.2 HEN-70 LEDs

ON/OFF LED

ALARM LED

ALARM LED

STATUS LED

MOD LED

CARRIER LED

17 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.3 Front panel The HEN-70 encoder is configured following a menus structure on the display. The front panel has 8 buttons to enter and exit the equipment’s

control menus and submenus and to navigate through them. The function of each button is detailed in the following sections.

Figure 3.3 HEN-70 front panel

3.3.1 ON/OFF Button

To switch the equipment on and off, press this button. When the equipment

is turned on, the display will show the start-up message (model and version of the equipment), and then it will display the main screen.

If the power fails while the equipment is operating, it will restart

automatically when the power returns, not being necessary to press the on/off button again.

Figure 3.4 ON/OFF button

Fan Display

Left Button

UP Button

Right Button

OK Button

Down Button

Cross Button

ON/OFF Button LEDs

TX Button

18 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.3.2 OK Button

This button is used to: Enter to submenus and change parameters. So as to access to a

submenu, OK button must be pressed. Moreover, in the fields where the enter symbol appears, by pressing the OK button the user can

change the values of the parameter selected. Besides, so as to save the introduced value, the OK button must be pressed.

In case of being in the main screen, pressing the OK button allows the user to access to the alarms screen where there are the different alarms

that are taking place. So as to return to the main screen, the cross button must be pressed.

Figure 3.5 OK button

3.3.3 Cross Button

This button is used to:

Enter from the equipment’s monitor menu to the setup menu and vice

versa.

Exit equipment’s submenus.

This button allows the user to access to the main screen from the alarms

screen.

Figure 3.6 Cross button

OK

X

19 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.3.4 Left and Right Button

These buttons are used to: Once the parameter to change has been selected, they are used to move

the cursor towards the digit immediately on the left or right and to select a parameter from different options.

Figure 3.7 Left and Right buttons

3.3.5 Up and Down Button

The up and down arrow buttons allow navigation in the main menu and

the rest of submenus. Using this buttons the user can enter to a submenu or change a parameter. Once selected, the OK button must be

pressed.

These buttons are also used to change some parameter’s values.

Pressing up and down arrows the value of those parameters can be changed, increased or decreased respectively, for example, in the BISS

encryption, the values of the introduced characters.

Figure 3.8 Up and Down buttons

20 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4 Menus There is one menu in this encoder which allows the user to change the encoder’s parameters and configure them.

To enter the menu of this equipment the cross button should be pressed.

In case it is wanted to return again to the main screen from the menu, the cross button must be pressed. Furthermore, in case of being in the submenus area, returning to the mainly screens is achieved by pressing the

cross button as much times as it is needed.

In the next page, a scheme that specifies the different menu options available is shown.

21 HEN-70_H.264 Encoder USER’S MANUAL V5.6

HEN-70 MENU STRUCTURE

continued

Format

Encoder

Video

MAIN SCREEN

Latency, output bitrate, audio and video status, profile.

SDI HDMI CVBS ASI IP

L Type

Format Status Format

Delay

Profile

Delay

Profile Profile

Delay

Format

Bitrate

Profile

Delay

Analogue Embedded AES-EBU Tone.Gen None

Audio 1

Bitrate Bitrate Bitrate Bitrate

Frequency

Level

continued

Format

GOP GOP GOP GOP

R Type

Gp

DID

GEN

Local IP

IP.Adr

Fec

Port

Out.Delay

TP per IP

Status

Protocol

Packet

Size

BitRate

PCR

22 HEN-70_H.264 Encoder USER’S MANUAL V5.6

continued

continued

continued

continued

Audio 2

Data

Analogue Embedded AES-EBU Tone.Gen None None GPS RS232

Bitrate

L Type

Bitrate Bitrate Bitrate

Frequency

Level

BaudRate

Parity

Stop Bits

Encoder

Output

Bitrate

Encoder

R Type

Gp

DID

23 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Local IP

DestinationIP&Port

Fec

TP per IP

Protocol

TTL

IP Out

TS

Parameters

Video PID

Audio1 PID

PMT PID

PCR PID

Data PID

Program Nº

Network

Name Audio2 PID

TS id

Network id

Service Name

CA-BISS

Mode

SW

User

None

BISS-1

BISS-E

Encoder

24 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Unit

Alarms

Monitor

Webserver

& SNMP

Miscellaneous

BUC S/S2

Unit

Self Check

Temp

Voltage

Local

Mask

Gateway

MAC

Admin Pass

Restore Admin Pass

User Pass

Restore User Pass

Keyboard Beep

Keyboard Lock

Night Mode

Dist Units

S/N

Firmware

Update Firmware

Restore Default

Rv

Alarms

Temp

Typ

MAC

25 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.1 Menu Navigation

This section contains a detailed description of each parameter that can be

configured in the HEN-70 encoder via the MENU.

To enter the MENU, press the cross button in case of being in the main screen or in any submenu.

To select a parameter or a submenu use Up, Down arrows. Once selected, press the OK button to access to a submenu or to edit a parameter. To exit

a submenu or a parameter, press the cross button.

Figure means that to have access to the right image that button

must be pushed. Symbols <> mean that the parameter can be modified in the same screen

with the right and left keys.

Symbol means that pushing the OK button allows entering the options of the submenu.

Different types of parameters are available:

- Eligible: When the user can choose between predetermined

states. (They usually have the symbol <> near to them)

- Editable: When the user must enter a value in that option. (They

usually have the symbol near them). So as to save the introduced value, the OK button must be pressed.

- Reading: When the value of that parameter is a monitored

parameter that can’t be changed.

To change any parameter, press the OK button in the desired option and

then with the Up, Down buttons choose the value. Once the parameter is set, press OK so as to changes are done.

Next, the different menus and submenus with the options and eligible parameters are shown. Furthermore, in each figure, example parameters

are shown.

26 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2 Menu Structure

The following menu screen can be accessed by pressing the cross key from the monitoring menu.

Figure 3.9 Menu

Encoder – All the parameters related to the video, audio and data inputs are configured here. Besides, all video, audio, data encoding and multiplexing parameters are accessed here.

CA-BISS – The encryption of signals can be configured in this option.

IP Out – All the parameters related to the IP output are configured in this section.

Unit – Parameters related to the Web Server and other internal options of

the HEN-70 are configured here, as well as other characteristics of the device.

MAIN MENU Encoder IP Out

CA-BISS Unit

27 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1 Encoder Menu

By using the Up, Down arrow keys, select the Encoder option and press the OK key.

Figure 3.10 Encoder Menu

Line nº Function

1

Video:

In this field, the video input must be chosen with the Right and Left

buttons. Once the video input has been selected, press the OK

button so as to configure the parameters related to it.

The available options are:

SDI

HDMI

CVBS

ASI

IP

GEN

2

Audio 1:

In this field, the sort of audio signal introduced in the audio 1 input

can be chosen with right and left buttons. Once the audio 1 input

has been selected, press the OK button so as to configure the

parameters related to it.

The available options are:

Embedded

Analogue

AES-EBU

Tone.Gen

None

3

Audio 2:

In this field, the sort of audio signal introduced in the audio 2 input

can be chosen with right and left buttons. Once the audio 2 input

has been selected, press the OK button so as to configure the

parameters related to it.

ENCODER Video: SDI <> Audio1: Tone.Gen <>

Audio2: AES-EBU <>

ENCODER Data: GPS <> Encoder Output

TS Parameters

28 HEN-70_H.264 Encoder USER’S MANUAL V5.6

The available options are:

Embedded

Analogue

AES-EBU

Tone.Gen

None

4

Data:

In this field, the sort of data input can be selected.

The available options are:

None

GPS

RS-232

5

Encoder Output:

In this field, the encoder output can be selected. Pressing the OK

button, the output bitrate can be configured.

6

TS Parameters:

This file consists on the configuration of the parameters of the

Transport Stream. In this option, the different program identifiers

are configured.

Table 3.2 Encoder Menu

29 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.1 SDI Input

Figure 3.11 SDI Input Menu

Line nº Function

1

Format (SDI):

In this field, the format of the SDI input signal is displayed. (reading

parameter)

The available options are:

1080p (1920x1080) – 23.98/24/25/29.97/30/50/59.94/60 Hz

1080i (1920x1080) – 50/59.94/60 Hz

720p (1280x720) – 23.98/24/25/29.97/30/50/59.94/60 Hz

576i (720x576) – 50 Hz

480i (720x480) – 59.94 Hz

2

Delay:

In this field, the delay of the coding process is configured. So as to

select the desired delay, press Right, Left arrows buttons. (eligible

parameter)

The available options are:

Standard

Low Delay (3 frames of delay)

Super Low Delay (2 frames of delay)

Ultra Low Delay (1 frame of delay)

3

Profile:

In this field, the codification profile can be configured. So as to

select the desired profile, press Right, Left arrows buttons. (eligible

parameter)

The available options are:

4.2.0

4.2.2

ENCODER VIDEO SDI

Format: 1080/50i Delay: SuperLD 2F <> Profile: 4.2.0 >

ENCODER VIDEO SDI

GOP: Auto 12 >

30 HEN-70_H.264 Encoder USER’S MANUAL V5.6

4

GOP:

In this field, the group of figures parameter is displayed. It specifies

the order in which intra- and inter-frames are arranged. (eligible

parameter)

The available options are:

Auto

Manual (editable parameter)

Table 3.3 SDI Input menu options

In case HDMI video input is selected, it is necessary to specify the format

(1080p, 1080i, 720p). If any other video input (SDI, CVBS or ASI) is selected, then the encoder automatically captures its format and the frame rate. If the video format is changed, the time detection of this new format is

less than 15 seconds.

31 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.2 HDMI Input

Figure 3.12 HDMI Input Menu

Line nº Function

1

Format:

In this field, the format of the HDMI input signal must be selected.

So as to select a format first, press the OK button so as to enter to

the submenus where different formats available appear. Then,

choose the desired one with the UP, Down keys. (editable

parameter)

The available options are:

1080p (Only Standard Delay)

1080i

720p

2

Delay:

In this field, the delay of the coding process is configured. So as to

select the desired delay, press Right, Left arrows buttons. (eligible

parameter)

The available options are:

Standard

Low Delay (3 frames of delay)

Super Low Delay (2 frames of delay)

Ultra Low Delay (1 frame of delay)

3

Profile:

In this field, the codification profile can be configured. So as to

select the desired profile, press Right, Left arrows buttons. (editable

parameter)

The available options are:

4.2.0

4.2.2

ENCODER VIDEO HDMI

Format: 1080p Delay: Standard > Profile: 4.2.0 >

ENCODER VIDEO HDMI

GOP: Auto 12 >

32 HEN-70_H.264 Encoder USER’S MANUAL V5.6

4

GOP:

In this field, the group of figures parameter is displayed. It specifies

the order in which intra- and inter-frames are arranged. (eligible

parameter)

The available options are:

Auto

Manual (editable parameter)

Table 3.4 HDMI Input menu options

33 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.3 CVBS Input

Figure 3.13 CVBS Input Menu

Line nº Function

1

Format (CVBS):

In this field, the format of the CVBS input signal is displayed.

(reading parameter)

The available options are:

480i

576i

2

Delay:

In this field, the delay of the coding process is configured. So as to

select the desired delay, press Right, Left arrows buttons. (eligible

parameter)

The available options are:

Standard

Low Delay (3 frames of delay)

Super Low Delay (2 frames of delay)

Ultra Low Delay (1 frame of delay)

3

Profile:

In this field, the codification profile can be configured. So as to

select the desired profile, press Right, Left arrows buttons. (eligible

parameter)

The available options are:

4.2.0

4.2.2

ENCODER VIDEO CVBS

Format: 480i Delay: SuperLD 2F <> Profile: 4.2.0 >

ENCODER VIDEO CVBS

GOP: Auto 12 >

34 HEN-70_H.264 Encoder USER’S MANUAL V5.6

4

GOP:

In this field, the group of figures parameter is displayed. It specifies

the order in which intra- and inter-frames are arranged. (eligible

parameter)

The available options are:

Auto

Manual (editable parameter)

Table 3.5 CVBS Input menu options

35 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.4 ASI Input

Figure 3.14 ASI Input Menu

Line nº Function

1

Status:

In this field it is indicated if there is any ASI signal in the ASI input.

In case there is an ASI signal, this field will display the word

present. If there is no ASI signal then, no present will be displayed.

(reading parameter)

The available options are:

Present

No Present

2

Bitrate:

Here, the bitrate of the ASI input signal is shown. (reading

parameter)

3

Format:

In this field, the format of the ASI input signal is shown. (reading

parameter)

The available options are:

188 bytes

204 bytes

Table 3.6 ASI Input menu options

ASI INPUT

Status: Present Bitrate: 18.0Mb Format: 188

36 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.5 IP Input

Figure 3.15 IP Input Menu

IP INPUT

Local IP IP.Adr: Unicast >

Fec: Disable >

IP INPUT Port: 5600

Out. Delay: 128 ms TP per IP: 1

IP INPUT

Status: ENABLE Protocol: UDP

Packet Size: 188

IP INPUT BitRate: 0.00Mb

PCR: No Present

37 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Line nº Function

1

Local IP:

So as to configure the network parameters, press the OK button.

(editable parameters)

The available options are:

Local IP:

So as to establish the Local IP address, press the OK button and

then, with the UP, Down buttons change the value. If the user

wants to change from one character to another, press the Right,

Left buttons. So as to save the introduced value, press the OK

button. If this IP is the same as the IP for remote control

(Webserver / SNMP), the device shows a warning message.

Mask:

In this field the Subnet Mask address must be specified. So as to

establish the Subnet Mask address, press the OK button and

then, with the UP, Down buttons change the value. If the user

wants to change from one character to another, press the Right,

Left buttons. So as to save the introduced value, press the OK

button.

Gateway:

In this field the Gateway address must be specified. So as to

establish the Gateway address, press the OK button and then,

with the UP, Down buttons change the value. If the user wants

to change from one character to another, press the Right, Left

buttons. So as to save the introduced value, press the OK

button.

MAC Address:

The MAC address of the device is shown in the screen. (reading

parameter)

2

IP.Adr:

So as to select the short of address from which IP information is

received, press Right, Left buttons. (eligible parameters)

The available options are:

Unicast:

In case it is wanted to receive the signal from any single IP

address to this device, unicast option must be chosen.

Multicast:

In case the signal is received from a multicast address, that

multicast address must be configured in this field. So as to enter

the multicast address, press the OK button so as to be able to

configure the multicast address. (editable parameter)

38 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3

Fec:

So as to select if FEC is enabled or disabled in the received signal

press Right, Left buttons. (eligible parameter)

The available options are:

Enable Col: Row: (The IP Forward Error Correction is

composed by a number of FEC columns and rows. In this field it

is shown the number of FEC columns and rows of the received

signal) (reading parameter)

Disable

4

Port:

This field must be filled in with the port number of the decoder

device through which is going to receive the signal. So as to edit this

parameter, press the OK button and then, select the desired port

with the Up, Down, or Right, Left buttons. So as to save the

introduced value, press the OK button. (editable parameter)

5

Output Delay [1..9942]ms:

This delay means the time passed between the Transport Stream is

obtained in the decoder and the signal is taken out from the

decoder. So as to edit this parameter, press the OK button and then,

select the desired port with the Up, Down and Right, Left buttons.

So as to save the introduced value, press the OK button. (editable

parameter)

6

TP per IP:

This field displays the number of TS packets per IP packet. (reading

parameter)

7

Status:

This field displays the status of the IP input. (reading parameter)

8

Protocol:

This field displays the protocol used for the communication. (reading

parameter)

The possible options are:

UDP

RTP

39 HEN-70_H.264 Encoder USER’S MANUAL V5.6

9

Packet Size:

This field shows the size in bytes of the IP received packets.

(reading parameter)

10

BitRate:

This field displays the bitrate of the received signal. (reading

parameter)

11

PCR:

Program Clock Reference. To enable a decoder to present

synchronized content, such as audio tracks matching the associated

video, at least once each 100 ms a Program Clock Reference, or PCR

is transmitted in the adaptation field of an MPEG-2 transport stream

packet. The parameters displayed can be present or no present.

(reading parameter)

Table 3.7 IP Input Select menu option

If the IP input is selected then, the IP output option blinks due to it cannot

be used because it is already configured as IP input.

40 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.6 Generator Input

Figure 3.16 Generator Input Menu

Line nº Function

1

Format:

In this field the format of the video signal generated is displayed.

The only option available is 576/50i. (reading parameter)

2

Delay:

In this field, the delay of the coding process is configured. So as to

select the desired delay, press Right, Left arrows buttons. (eligible

parameter)

The available options are:

Standard

Low Delay (3 frames of delay)

Super Low Delay (2 frames of delay)

Ultra Low Delay (1 frame of delay)

3

Profile:

In this field, the codification profile can be configured. So as to

select the desired profile, press Right, Left arrows buttons. (eligible

parameter)

The available options are:

4.2.0

4.2.2

4

GOP:

In this field, the group of figures parameter is displayed. It specifies

the order in which intra- and inter-frames are arranged. (eligible

parameter)

The available options are:

Auto

Manual (editable parameter)

Table 3.8 Generator Input menu

ENCODER VIDEO GEN

Format: 576/50i Delay: SuperLD 2F <> Profile: 4.2.0 >

ENCODER VIDEO GEN

GOP: Auto 12 >

41 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.7 Audio1 Embedded

Figure 3.17 Audio Embedded Input Menu

Line nº Function

1

Bitrate:

In this option, the bitrate for the codification of the audio signal 1

can be selected. So as to select the desired bitrate, press Right, Left

arrows buttons. (eligible parameter)

The available options are:

128K

192K

256K

384K

2

Group:

In this field the different numbers of input groups are displayed. In

case one group is not present then, a line appears. (reading

parameter)

DID:

In this field, the desired group can be selected. So as to select the

group, press Right, Left buttons. (eligible parameter)

The available options are:

G0

G1

G2

G3

Table 3.9 Audio Embedded Input menu options

If the video option selected is CVBS, ASI, IP or Test Pattern Generator then, the option of audio embedded will be blinking because that configuration is

not possible.

ENCODER AUDIO1 Bitrate: 256K <>

Gp: (1234) DID:G0 <>

42 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.8 Audio1 Analogue

Figure 3.18 Audio Analogue Input Menu

Line nº Function

1

Bitrate:

In this option, the bitrate for the codification of the audio signal 1

can be selected. So as to select the desired bitrate, press Right, Left

arrows buttons. (eligible parameter)

The available options are:

128K

192K

256K

384K

2

L Type:

In this field, the sort of signal of the audio 1 left channel introduced

in the device is selected. So as to choose the type of audio1, press

Right, Left buttons. (eligible parameter)

The available options are:

Line

Mic Dynamic

Mic Phantom

3

R Type:

In this field, the sort of signal of the audio 1 right channel

introduced in the device is selected. So as to choose the type of

audio1, press Right, Left buttons. (eligible parameter)

The available options are:

Line

Mic Dynamic

Mic Phantom

Table 3.10 Audio Analogue Input menu options

ENCODER AUDIO1 Bitrate: 256K <>

L Type: Line > R Type: Line >

43 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.9 Audio1 AES-EBU

Figure 3.19 Audio AES-EBU Input Menu

Line nº Function

1

Bitrate:

In this option, the bitrate for the codification of the audio signal 1

can be selected. So as to select the desired bitrate, press Right, Left

arrows buttons. (eligible parameter)

The available options are:

128K

192K

256K

384K

Table 3.11 Audio AES-EBU Input menu options

ENCODER AUDIO1 Bitrate: 384K <

44 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.10 Audio1 Tone.Gen

Figure 3.20 Audio Generator Input Menu

Line nº Function

1

Bitrate:

In this option, the bitrate for the codification of the audio signal 1

can be selected. So as to select the desired bitrate, press Right, Left

arrows buttons. (eligible parameter)

The available options are:

128K

192K

256K

384K

2

Frequency (Hz):

In this field, the frequency of the generated tone is displayed.

(reading parameter)

3

Level (dBFs):

In this field, the level in dBF of the generated tone is displayed.

(reading parameter)

Table 3.12 Audio Generator Input menu options

ENCODER AUDIO1

Bitrate: 384K < Frequency: 1000Hz

Level: 18dBFs

45 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.11 Audio2 Embedded

Figure 3.21 Audio Embedded Input Menu

Line nº Function

1

Bitrate:

In this option, the bitrate for the codification of the audio signal 2

can be selected. So as to select the desired bitrate, press Right, Left

arrows buttons. (eligible parameter)

The available options are:

128K

192K

256K

384K

2

Group:

In this field the different numbers of input groups are displayed. In

case one group is not present then, a line appears. (reading

parameter)

DID:

In this field, the desired group can be selected. So as to select the

group, press Right, Left buttons. (eligible parameter)

The available options are:

G0

G1

G2

G3

Table 3.13 Audio Embedded Input menu options

If the video option selected is CVBS, ASI, IP or Test Pattern Generator then,

the option of audio embedded will be blinking because that configuration is not possible.

ENCODER AUDIO2 Bitrate:256K <>

Gp: (1234) DID:G0 <>

46 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.12 Audio2 Analogue

Figure 3.22 Audio Analogue Input Menu

Line nº Function

1

Bitrate:

In this option, the bitrate for the codification of the audio signal 2

can be selected. So as to select the desired bitrate, press Right, Left

arrows buttons. (eligible parameter)

The available options are:

128K

192K

256K

384K

2

L Type:

In this field, the sort of signal of the audio 2 left channel introduced

in the device is selected. So as to choose the type of audio2, press

Right, Left buttons. (eligible parameter)

The available options are:

Line

Mic Dynamic

Mic Phantom

3

R Type:

In this field, the sort of signal of the audio 2 right channel

introduced in the device is selected. So as to choose the type of

audio2, press Right, Left buttons. (eligible parameter)

The available options are:

Line

Mic Dynamic

Mic Phantom

Table 3.14 Audio Input menu options

ENCODER AUDIO2 Bitrate: 256K <>

L Type: Line > R Type: Line >

47 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.13 Audio2 AES-EBU

Figure 3.23 Audio AES-EBU Input Menu

Line nº Function

1

Bitrate:

In this option, the bitrate for the codification of the audio signal 2

can be selected. So as to select the desired bitrate, press Right, Left

arrows buttons. (eligible parameter)

The available options are:

128K

192K

256K

384K

Table 3.15 Audio AES-EBU Input menu options

ENCODER AUDIO2 Bitrate: 384K <

48 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.14 Audio2 Tone.Gen

Figure 3.24 Audio Generator Input Menu

Line nº Function

1

Bitrate:

In this option, the bitrate for the codification of the audio signal 2

can be selected. So as to select the desired bitrate, press Right, Left

arrows buttons. (eligible parameter)

The available options are:

128K

192K

256K

384K

2

Frequency (Hz):

In this field, the frequency of the generated tone is displayed.

(reading parameter)

3

Level (dBFs):

In this field, the level in dBF of the generated tone is displayed.

(reading parameter)

Table 3.16 Audio Generator Input menu options

ENCODER AUDIO2 Bitrate: 384K <>

Frequency: 1000Hz Level: 18dBFs

49 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.15 Data

So as to select the desired sort of data, press Right, Left buttons. (eligible parameter)

The available options are: None, GPS and RS232.

None This option is selected in case no data is sent to the device.

Figure 3.25 None screen

GPS Screen

If this option is selected and the GPS antenna is connected to the GPS input of the device, then, by pressing the OK button, the user can access to the

different parameters sent by the GPS.

So as to access to the GPS screen first, go to the encoder option in the menu. Then, go to the Data option and select GPS with the Right, Left keys. Next, press the OK button so as to access to the GPS screen. Below, there

are shown the different parameters which appear in the GPS screen.

Figure 3.26 GPS screen

#--º--.---´ ---k ---º #---º--.---´ -----mt Satellite Level --/--/--

--:--:--

Level of the satellite signals Time

Date

Height (meters)

Speed(knot)/

Direction(degrees)

Longitude of the encoder

Latitude of the encoder

ENCODER Data: None <

Encoder Output TS Parameters

ENCODER

Data: GPS <> Encoder Output TS Parameters

OK

50 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Next, the different meanings of each field are shown:

Latitude of the encoder: It specifies the latitude position of the

encoder.

Speed of the encoder: It shows the speed of the encoder in knot.

Direction of the encoder: The direction of the encoder is shown in this

field.

Longitude of the encoder: It specifies the longitude position of the

encoder.

Height of the encoder: The height of the encoder from ground is

specified in this value.

Satellite Level: The level of each satellite signal received is shown in

this field.

Date: The updated date is shown.

RS232

If it is wanted to send data to the device through a RS232 connection, this option must be selected. It is also needed to configure the next parameters

so as to achieve a successful communication.

Figure 3.27 RS232 screen

ENCODER Data: RS232 < Encoder Output

TS Parameters

OK

DATA INPUT RS232 BaudRate: 57600 <

Parity: None > Stop Bits: 1 >

51 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Data option Parameters

1

BaudRate:

Select the baudrate at which data user is received. (Baudrate

options are: 1200, 2400, 4800, 9600, 19200, 38400, 57600)

(eligible parameters)

2

Parity:

Select the same parity as the parity of the received data user signal.

(Parity options are None, Even, Odd) (eligible parameters)

3

Stop Bits:

Select the same number of stop bits as the received data user signal

has. (Stop bit options are 1 or 2) (eligible parameter)

Table 3.17 RS232 Parameters

52 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.16 Encoder Output

Figure 3.28 Encoder Output Menu

Line nº Function

1

BitRate:

In this field, the output bitrate is shown. It case it is wanted to

select between an automatic bitrate or configure manually the

bitrate, press Right, Left buttons. If manual configuration is selected

then, press the OK button so as to select the desired bitrate with the

UP, Down keys. Press the OK button so as to save the introduced

value. (eligible parameter)

The available options are:

Auto

Manual (editable parameter)

Table 3.18 Encoder Output menu options

In case the user selects the manual option, if the output bitrate is higher

than the one that is achievable with the selected configuration (modulation

scheme, FEC) then, in the main screen the line (third line) in which these parameters (modulation scheme, FEC, bitrate) appear blinks.

ENCODER OUTPUT

BitRate: 10.0Mb

53 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.1.17 TS Parameters

Figure 3.29 Encoder TS Menu

Line nº Function

1

Service Name:

Here the Service name must be entered. So as to change its value,

first, press the OK button and then, with the UP, Down arrows select

the desired letter. With the Right, Left keys, the user can select the

character of the word. Press the OK button so as to save the

introduced value. (editable parameter)

2

Program Nº:

Here the program number must be entered. So as to change its

value first, press the OK button and then, with the UP, Down arrows

select the desired number. Press the OK button so as to save the

introduced value. (editable parameter)

3

Video PID:

Here the video packet identifier must be entered. So as to change its

value first, press the OK button and then, with the UP, Down arrows

select the desired number. Press the OK button so as to save the

introduced value. (editable parameter)

ENCODER TS

Service Name Program Nº: 1

Video PID: 273

ENCODER TS

Audio 1 PID: 512 Audio 2 PID: 513

Data PID: 2100

ENCODER TS PMT PID: 291 PCR PID: 256

TS id: 7

ENCODER TS Network id: 7

Network Name

54 HEN-70_H.264 Encoder USER’S MANUAL V5.6

4

Audio1 PID:

Here the audio1 packet identifier must be entered. So as to change

its value first, press the OK button and then, with the UP, Down

arrows select the desired number. Press the OK button so as to save

the introduced value. (editable parameter)

5

Audio2 PID:

Here the audio2 packet identifier must be entered. So as to change

its value first, press the OK button and then, with the UP, Down

arrows select the desired number. Press the OK button so as to save

the introduced value. (editable parameter)

6

Data PID:

Here the data packet identifier must be entered. So as to change its

value first, press the OK button and then, with the UP, Down arrows

select the desired number. Press the OK button so as to save the

introduced value. (editable parameter)

7

PMT PID:

Here the program map tables packet identifier must be entered. So

as to change its value first, press the OK button and then, with the

UP, Down arrows select the desired number. Press the OK button so

as to save the introduced value. (editable parameter)

8

PCR PID:

Here the program clock reference packet identifier must be entered.

So as to change its value first, press the OK button and then, with

the UP, Down arrows select the desired number. Press the OK

button so as to save the introduced value. (editable parameter)

9

TS id:

Here the Transport Stream identifier must be entered. So as to

change its value first, press the OK button and then, with the UP,

Down arrows select the desired number. Press the OK button so as

to save the introduced value. (editable parameter)

10

Network id:

Here the Network identifier must be entered. So as to change its

value first, press the OK button and then, with the UP, Down arrows

select the desired number. Press the OK button so as to save the

introduced value. (editable parameter)

55 HEN-70_H.264 Encoder USER’S MANUAL V5.6

11

Network Name:

Here the Network name must be entered. So as to change its value

first, press the OK button and then, with the UP, Down arrows select

the desired letter. With the Right, Left keys, the user can select the

character of the word. Press the OK button so as to save the

introduced value. (editable parameter)

Table 3.19 Encoder TS menu options

56 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.2 CA-BISS Menu

By using the Up, Down arrow keys, select the CA-BISS option and press the OK key.

Figure 3.30 CA-BISS Menu

Line nº Function

1

Mode:

So as to choose the desired encryption, press the Right, Left keys.

(eligible parameter)

The available options are:

None

BISS-1 (Uses an unencrypted key for the BISS key)

BISS-E (Uses an encrypted key)

2

SW:

In this field, the SW password must be introduced, which is valid for

BISS-1 and BISS-E encryption. (editable parameter)

3

User:

In this field, the User password must be introduced, which is valid

only for BISS-E encryption. (editable parameter)

Table 3.20 CA-BISS menu options

CONDITIONAL ACCESS

Mode: BISS-E < SW: *****************

User: ****************

57 HEN-70_H.264 Encoder USER’S MANUAL V5.6

So as to introduce the key in the BISS-1 option, follow these steps:

1. Choose the BISS-1 option in the Mode field. 2. Go one field down (SW) and press the OK button so as to be allowed

to introduce the key. 3. With Left and Right buttons select one field and with UP, Down

buttons choose one value from 0 to 9 or A to F. 4. Press the OK button to set the key.

So as to introduce the key in the BISS-E option, follow these steps:

1. Choose the BISS-E option in the Mode field. 2. Go one field down (SW) and press the OK button so as to be allowed

to introduce the key. 3. With Left and Right buttons select one field and with UP, Down

buttons choose one value from 0 to 9 or A to F.

4. Press the OK button to set the key. 5. Go another field down (User) and press the OK button so as to be

allowed to introduce the User. 6. With Left, Right buttons select one field and with UP and Down

buttons choose one value from 0 to 9 or A to F.

7. Press the OK button to set the User.

BISS encryption is activated in the ASI output.

58 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.3 IP Out

By using the Up, Down arrow keys, select the IP Out option and press the OK key.

Figure 3.31 IP Out Menu

Line nº Function

1

Local IP:

In this option it can be set the IP address, Mask, Gateway and MAC

of the device in case it is wanted to control the device remotely. So

as to change those parameters, press the OK button and then, with

the Up and Down keys select the desired option.

- LOC:

IP address of the device which is going to send the

information. So as to change the IP address first press OK

button and then, with the Up, Down keys select the desired

number. So as to change from one character to another,

press Right, Left keys. So as to save the value, press the OK

button. (editable parameter)

- MSK:

Subnet address of the device which is going to send the

information. So as to change the Subnet Mask address first

press the OK button and then, with the Up, Down keys select

the desired number. So as to change from one character to

another, press Right, Left keys. So as to save the value,

press the OK button. (editable parameter)

- GAT:

Gateway address of the device which is going to send the

information. So as to change the Gateway address first press

the OK button and then, with the Up, Down keys select the

desired number. So as to change from one character to

another, press Right, Left keys. So as to save the value,

press the OK button. (editable parameter)

- MAC ADDRESS

The MAC Address of the transmitter is shown. (reading

parameter)

IP OUT Local IP DestinationIP&Port

Fec: Disable >

IP OUT TP per IP: 7 (1..7) < Protocol: UDP >

TTL: 80 (1...255)

59 HEN-70_H.264 Encoder USER’S MANUAL V5.6

2

Destination IP & Port:

In this option, the IP address and the port number of the device to

which data is sent must be configured. In case it is wanted to send

data to a multicast address just enter the desired multicast address.

So as to change the IP address and the port number, first press the

OK button and then, with the Up, Down keys select the desired

number. So as to change from one character to another, press

Right, Left keys. So as to save the value, press the OK button.

(editable parameter)

3

FEC:

In this field, the Forward Error Correction can be enabled or

disabled. In case it is enabled, the number of columns and rows can

be configured pushing firstly the OK button and then, with the Up,

Down arrows, the number of columns and rows wanted can be

selected. If FEC option is enabled then, the only protocol which can

be used is RTP. (eligible parameter)

4

TP per IP:

In this field, the number of Transport Stream packets per IP (from 1

to 7) can be configured. So as to select the desired value, press the

Right, Left buttons. (eligible parameter)

5

Protocol:

The type of protocol used for the communication can be RTP or UDP.

So as to select the desired protocol for the communication, use

Right, Left buttons. (eligible parameter)

6

TTL:

This field limits the lifetime of data. The Time to Live value (from 1

to 255) means the number of routers that a packet can reach until

that packet is discarded. So as to configure this value, first press the

OK button and then, with the Up, Down, and Right, Left buttons

select the desired value. So as to save the value, press the OK

button. (editable parameter)

Table 3.21 IP OUT menu options

60 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.4 Unit Menu

By using the Up, Down arrow keys, select the Unit option and press the OK key.

Figure 3.32 Unit Menu

3.4.2.4.1 Alarms

In this option, different alarms which are present in the device are shown.

The alarm screen can be accessed by pressing the OK button from the main screen as well. So as to return to the main screen from the alarm screen, cross button must be pressed.

The different alarms that can appear in the transmitter are:

Voltage High. Voltage Low.

Temperature High. ASI Overflow: this alarm means that the input bitrate is higher than

the one that can be modulated due to the parameters configured (constellation, FEC, GI...).

The different warnings that can appear in the transmitter are:

No Video Input. No GPS.

UNIT

Alarms (02) Monitor

Webserver & SNMP

UNIT

Miscellaneous Firmware

BUC S/S2 Unit

61 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.4.2 Monitor

Figure 3.33 Unit Monitor Menu

Temperature:

In this field, the internal temperature of the device is displayed. With

the Right, Left keys, the user can select if the temperature is shown in ºC or in ºF. Also, the value which is between square brackets means the speed of the fans (values from 0 to 3) where 0 means that

the fans are stopped and value 3 is the maximum speed. (Reading parameter)

Voltage:

In this field, the voltage of the device is shown. (Reading parameter)

UNIT MONITOR

Self Check: OK Temp: +37,1ºC (0) >

Voltage: +11.6V

62 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.4.3 Webserver & SNMP

Figure 3.34 Webserver & SNMP Menu

Line nº Function

1

Local IP:

In this option it can be set the IP address of the device in case it is

wanted to control the device remotely. So as to change the IP

address first press the OK button and then, with the Up and Down

keys select the desired number. So as to change from one character

to another, press Right and Left keys. Press the OK button so as to

save the introduced value. (editable parameter)

2

Subnet Mask:

Here, the Subnet Mask address of the device can be written. So as

to change the Subnet Mask address first press the OK button and

then, with the Up and Down keys select the desired number. So as

to change from one character to another, press Right and Left keys.

Press the OK button so as to save the introduced value. (editable

parameter)

3

Gateway:

In this option, the address of the Gateway must be written. So as to

change the Gateway address first, press the OK button and then,

with the Up and Down keys select the desired number. So as to

change from one character to another, press Right and Left keys.

Press the OK button so as to save the introduced value. (editable

parameter)

4

MAC ADDRESS

In this field, the MAC address of the device is shown. (reading

parameter)

UNIT ETHERNET

LOC 192.168.001.010 MSK 255.255.000.000 GAT 192.168.001.001

UNIT ETHERNET

70-B3-D5-1A-C0-00 Admin Pass: ********

Restore Admin Pas

UNIT ETHERNET

User Pass: ******** Restores User Pas

63 HEN-70_H.264 Encoder USER’S MANUAL V5.6

5

Admin Pass:

The administrator’s password is introduced. It can be set an own

password which is a list of 8 digits.

To set the password, press the OK button and the use the Up and

Down button to establish the desired value, the press Right and Left

buttons to change other digits. Finally press the OK button to save

the introduced values.

6

Restore Admin Pass:

This option enables to restore the default administrator password

(00000000).

7

User Pass:

The user’s password is introduced. It can be set an own password

which is a list of 8 digits.

To set the password, press the OK button and then use the Up and

Down button to establish the desired value, the press Right and Left

buttons to change other digits. Finally press the OK button to save

the introduced values.

8

Restore User Pass:

This option enables to restore the default user password

(00000000).

Table 3.22 Unit Ethernet menu options

64 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.4.4 Miscellaneous

Figure 3.35 Miscellaneous Menu

Line nº Function

1

Keyboard Beep:

If the option On is selected then, each time a key is pressed a beep

sound will appear. If the option Off is selected, then, there will not

be sound when a key is pressed. (eligible parameter)

The available options are:

On

Off

2

Keyboard Lock:

If the On option is selected and then, the buttons of the equipment

remain for 5 minutes without being pressed, a message will appear

in the screen saying that the keyboard is locked. Pressing the cross

button, the keyboard can be unlocked. If the Off option is selected

there will be no messages in the screen.

The available options are:

On

Off

3

Night Mode:

There are four possible states for the night mode. If night mode is in

state 0, then the light in the screen will shine more than if it is in

state 1. If the state is three then, the light in the screen will be the

lowest of the four possible states. (eligible parameter)

The available options are:

0

1

2

3

UNIT MISCELLANEOUS

Keyboard Beep: Off < Keyboard Lock: Off < Night Mode: 0 >

UNIT MISCELLANEOUS

Dist Units: Km > S/N: 660010911 70-B3-D5-1A-C0-00

65 HEN-70_H.264 Encoder USER’S MANUAL V5.6

4

Dist Units:

If miles is selected then, all the distances will be in miles and the

same occurs if kilometers is selected. (eligible parameter)

The available options are:

Kilometers

Miles

5

S/N:

In this field the serial number of the device is shown (reading

parameter).

6

MAC Address:

The MAC Address of the transmitter is shown. (reading parameter)

Table 3.23 Unit Miscellaneous menu options

66 HEN-70_H.264 Encoder USER’S MANUAL V5.6

3.4.2.4.5 Firmware

Figure 3.36 Firmware Menu

Line nº Function

1

Update Firmware:

This field is the one for updating the version of the device. So as to

update the equipment properly, follow the instructions below.

2

Restore Default:

In this option, the equipment is restored to the first factory version.

So as to restore the equipment to the initial set up, press the OK

button.

3

Rev:

In this field it is shown the number of the version installed in the

device. The characters which describe the number of the version are

the one inside the red box shown in the figure above. The rest of the

characters are important for the manufacturer but are not important

for the user.

Table 3.24 Unit Firmware menu options

Update Firmware

Restore Default Rev: V5.3901391917-18

Number of the version of the device

67 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Next, the necessary steps so as to make a successful update are explained.

1) The latest firmware is allocated in the webpage of SVP Broadcast Microwave. So as to access to the firmware file, first enter www.svpbm.com in your web browser.

2) Click on the Support tab.

Figure 3.37 Updating firmware step 2

3) Click on Firmware.

68 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Figure 3.38 Updating firmware step 3

4) Go to TX_Firmware.

Figure 3.39 Updating firmware step 4

5) Press the Download button so as to download the file.

69 HEN-70_H.264 Encoder USER’S MANUAL V5.6

To verify the version of the device, go to firmware field and then look

at the Rv option to check the number of the version installed in the device (the first two digits).

Figure 3.40 Updating firmware step 5

6) Once the firmware file has been downloaded, save it in a USB device.

In the USB device, the only file that can be allocated inside it is the

firmware file of the device to be updated.

7) With the equipment completely power off (with no power

supply), insert the USB device in the USB connector, situated in the rear panel.

Before introducing the USB device, remove the power supply of the

equipment.

8) Now, switch on the device.

9) Go to Unit menu. In case of being in the main screen, press cross

button so as to access to the menu. There, with the Up, Down buttons, select the Unit option.

10) Select Firmware by pressing the OK button.

11) Select Check USB Memory with the OK button.

70 HEN-70_H.264 Encoder USER’S MANUAL V5.6

12) Now, automatically the device updates the firmware. The screens

which are shown below display the different steps that the device is making while the updating process.

Don’t power off the device during the updating process.

3.4.2.4.6 BUC S/S2 Unit

Figure 3.41 BUC S/S2 Unit Menu

When a BUC is connected to the device, the followings options of the BUC

are available.

Line nº Function

1

Alarms:

The alarms of the connected BUC are shown.

2

Temperature:

In this option, the temperature of the BUC is shown in the screen.

3

Type:

In this option, the type and the model of the BUC is shown in the

screen.

The available options are:

IRT

WAVE

Table 3.25 BUC S/S2 Unit menu options

Alarms (None) Temp: +40,8 ºC

Typ: IRT (KXB0470) >

71 HEN-70_H.264 Encoder USER’S MANUAL V5.6

69.200

HAUG -------- 420S XXX/XX

Chapter 4: GPS Application

4.1 Introduction The HEN-70 encoder has a GPS antenna input in order to give information

to the device about the positioning data. Connecting the GPS antenna to this input, allows the transference of the information given.

Once the information is kept inside the device, it can be sent from the ASI

or TS over IP output to the MOD-70 modulator and then to the IRD-70. If the signal arrives correctly to the receiver system, then the IRD-70 will have all the GPS data available and this receiver device will be able to

calculate the direction, distance, positioning... of the transmitter.

The IRD-70 also includes another feature that consists on an output RS232 connection which allows watching throughout Google Maps application the position of the transmitter in real time.

Figure 4.1 GPS antenna

4.2 Main Screen

Next it is explained the value of the data field which appears in the main screen of the HEN-70 encoder.

Figure 4.2 Main screen

The data status field indicates with a darkened X that it is disabled. When

this parameter is enabled and blinkers, this means that there is nothing connected to the data input. When this field alternates the value between

‘g’ and ‘G’, it means that it is trying to get the GPS satellites. If the ‘G’ does not vary, then it is connected to the satellites.

72 HEN-70_H.264 Encoder USER’S MANUAL V5.6

4.3 GPS encoder screen So as to access to the GPS screen, go to the encoder option in the menu.

Once inside this option, go to the Data field and choose GPS. Press the OK

button and then the GPS screen appears.

Next, the different field’s meanings are shown.

Figure 4.3 GPS encoder screen

Longitude of the encoder: It specifies the longitude position of the

encoder.

Speed of the encoder: It shows the speed of the encoder in knot.

Direction of the encoder: The direction of the encoder is shown in this

field.

Latitude of the encoder: It specifies the latitude position of the

encoder.

Height of the encoder: The height of the encoder from ground is

specified in this value.

Satellite Level: The level of each satellite signal received is shown in

this field.

Date: The updated date is shown.

#--º--.---´ ---k ---º

#---º--.---´ -----mt Satellite Level --/--/--

--:--:--

Level of the satellite signals Time

Date

Height (meters)

Speed(knot)/ Direction(degrees)

Longitude of the encoder

Latitude of the encoder

73 HEN-70_H.264 Encoder USER’S MANUAL V5.6

4.4 Application example Suppose it is wanted to know the constant positioning of the transmitter device. This is achievable with the next items:

- MOD-70 modulator

- HEN-70 encoder - GPS antenna - IRD-70 decoder

With the GPS antenna connected to the HEN-70, positioning of the device is

achieved once the GPS system is connected to the necessary satellites. Data obtained in the transmitter is the positioning of the device.

Next, this GPS data is sent to the MOD-70 through the ASI or TS over IP output and then, the modulator sends this data through the RF output until

it reaches the receiver system.

In the next page, a picture of this system is shown:

74 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Figure 4.4 GPS system example picture

MOD-70 modulator

IRD-70 GPS screen

IRD-70 Demodulator & Decoder

E20º45.512´ 10k47º1mt 04/10/13

N60º73.984´ S3 100km 100º 09:45:34

RS232 connection

PC with Google Earth

Video GPS

- Power Aplifier

- Up Converter

- Parabolic Antenna

Transmitter System

Receiver System

TS over IP

or ASI

HEN-70 encoder

75 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Chapter 5: Web Server

5.1 Introduction This equipment can be controlled by the use of a PC connected at the rear

panel Ethernet connector.

To enable the browser interface correctly, the IP address, Subnet Mask, Gateway, User Password and Administrator Password need to be set

correctly on this unit. Next, the steps so as to setup network parameters are shown:

1. Go to Unit -> Webserver & SNMP

Figure 5.1 Web Server screen

2. Select LOC option and set an IP address. So as to change the IP

address first press the OK button and then, with the Up, Down keys select the desired number. So as to change from one character to another, press Right, Left keys. Press the OK button so as to save the

introduced value.

Figure 5.2 Local IP

3. Select MSK option and set the Subnet Mask address. So as to change the Subnet Mask address first press the OK button and then, with the

Up, Down keys select the desired number. So as to change from one character to another, press Right, Left keys. Press the OK button so as to save the introduced value.

Figure 5.3 Subnet Mask

UNIT ETHERNET LOC 192.168.001.010

MSK 255.255.000.000 GAT 192.168.001.001

MAIN MENU Encoder IP Out

CA-BISS Unit

UNIT ETHERNET LOC 192.168.001.010

MSK 255.255.000.000 GAT 192.168.001.001

UNIT ETHERNET LOC 192.168.001.010

MSK 255.255.000.000 GAT 192.168.001.001

76 HEN-70_H.264 Encoder USER’S MANUAL V5.6

4. Select GAT option and set the Gateway address. So as to change the Gateway address first press the OK button and then, with the Up,

Down keys select the desired number. So as to change from one character to another, press Right, Left keys. Press the OK button so as to save the introduced value.

Figure 5.4 Gateway

5. Select Admin Pass option and set the administrator’s password. If it is

wanted to access to the Webserver directly without setting any

password, the Admin Pass must be set to 0 (00000000). However, if it is wanted to set an administrator’s password, it is necessary to

introduce 8 digits. In this way, with this password, the administrator can access to the Webserver and make any configuration, modification or monitoring.

Figure 5.5 Admin Pass

6. Select Restore Admin Pass option to restore de default value of the

administrator’s password.

Figure 5.6 Restore Admin Pass

7. Select User Pass option and set the user’s password. If it is wanted to access to the Webserver directly without setting any password, the User Pass must be set to 0 (00000000). However, if it is wanted to

set a user’s password, it is necessary to introduce 8 digits. In this way, with this password, the user can access to the Webserver and

make any monitoring.

UNIT ETHERNET

LOC 192.168.001.010 MSK 255.255.000.000

GAT 192.168.001.001

UNIT ETHERNET

70-B3-D5-1A-C0-00 Admin Pass: ********

Restore Admin Pas

UNIT ETHERNET

70-B3-D5-1A-C0-00 Admin Pass: ******** Restore Admin Pas

77 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Figure 5.7 User Pass

8. Select Restore User Pass option to restore de default value of the

administrator’s password.

Figure 5.8 Restore User Pass

Once the IP, Subnet Mask, Gateway, User Password and Admin Password are set and the laptop or PC is connected to the HEN-70, open the web browser and tip the IP given to the device.

Press enter button in your computer and then the main screen will appear.

5.2 Web Page Overview

The main menu is set in the upper position of the screen. Once an option is chosen, it is possible to change any parameter allowed or to see the values of some options.

In order to modify any parameter, introduce or select the new one and

press enter button. Then the change will be set in the encoder device. Next, several screens of the web server and their features are shown.

UNIT ETHERNET

User Pass: ******** Restore User Pas

UNIT ETHERNET User Pass: ********

Restore User Pas

78 HEN-70_H.264 Encoder USER’S MANUAL V5.6

5.2.1 ENCODER

Figure 5.9 Web Server Encoder screen

5.2.1.1 Video

- Input:

Select the type of the video input. The video input options available are SDI, HDMI, CVBS, ASI, IP and Test Pattern. (eligible parameter)

In case IP input is selected, the parameters related to this input can

be configured in the TSoIP screen.

- Format:

Here the format of the video input signal is displayed. If there is no video input then the message ‘not detected’ is displayed. (reading

parameter)

79 HEN-70_H.264 Encoder USER’S MANUAL V5.6

- Bitrate:

In this field the bitrate of the input signal in Mbps is displayed. (reading parameter)

- Delay:

In this field, the delay of the coding process is configured. The available options are Standard Delay, Low Delay, Super Low Delay or Ultra Low Delay. (eligible parameter)

- Profile:

In this field, the codification profile can be configured. The available

options are 4:2:0 and 4:2:2. (eligible parameter)

- GOP Size:

In this field, the group of figures parameter is displayed. It specifies

the order in which intra- and inter-frames are arranged. (eligible parameter)

The available options are:

Auto Manual (editable parameter)

Then the GOP size can be configured. The available options are (3, 6, 9, 12, 15, 18, 21, 24, 27, and 30).

5.2.1.2 Audio

- [A1] Input:

Select the type of signal introduced in the audio 1 input. The audio input options available are Embedded, Analogue, AES-EBU, Test Tone

Generator and None. (eligible parameter)

- [A1] Bitrate: Select the bitrate for the coding process of the audio 1 signal. The

available options are 128, 192, 256 and 384 Kbps. (eligible parameter)

- [A2] Input:

Select the type of signal introduced in the audio 2 input. The audio input options available are Embedded, Analogue, AES-EBU, Test Tone

Generator and None. (eligible parameter)

80 HEN-70_H.264 Encoder USER’S MANUAL V5.6

- [A2] Bitrate:

Select the bitrate for the coding process of the audio 2 signal. The available options are 128, 192, 256 and 384 Kbps. (eligible parameter)

5.2.1.3 Data

- Input:

Select the type of data introduced to the device. The available options are None, GPS and RS232. (eligible parameter)

5.2.1.3.1 RS-232

If it is wanted to send data to the device through a RS232 connection, this

option must be selected. It is also needed to configure the next parameters so as to achieve a successful communication:

- Baudrate:

Choose the baudrate of the RS-232 connection. The available options are 1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600. (eligible

parameter)

- Parity: Select the parity for the RS-232 connection. The available options are

None, ODD and Even. (eligible parameter)

- Stop Bits: Establish the number of stop bits for the RS-232 connection. The

available options are 1 and 2. (eligible parameter)

81 HEN-70_H.264 Encoder USER’S MANUAL V5.6

5.2.1.3.2 GPS

If GPS data is selected and the GPS antenna is connected to the device, then different parameters as shown in chapter 4 appear:

Figure 5.10 Web Server GPS screen

The format of the GPS coordinates used is decimal minutes as shown in the

next example:

N43º02.032’

W023º03.023’

- Status:

The status of the GPS input is displayed in this field. (reading parameter)

- Latitude:

It specifies the latitude position of the device. (reading parameter)

- Longitude: It specifies the longitude position of the device. (reading parameter)

- Altitude:

The height of the device from ground in meters is specified in this

value. (reading parameter)

- Direction:

The direction in degrees of the device is shown in this field. (reading

parameter)

82 HEN-70_H.264 Encoder USER’S MANUAL V5.6

- Speed:

The speed of the device in km/h is shown in this field. (reading parameter)

5.2.1.4 TS Parameters

- Video PID:

Here the video packet identifier must be entered. (editable parameter)

- Audio 1 PID:

Here the audio 1 packet identifier must be entered. (editable parameter)

- Audio 2 PID:

Here the audio 2 packet identifier must be entered. (editable parameter)

- Data PID:

Here the data packet identifier must be entered. (editable parameter)

- PMT PID:

Here the program map tables packet identifier must be entered. (editable parameter)

- PCR PID:

Here the program clock reference packet identifier must be entered. (editable parameter)

- Program Number:

Here the program number must be entered. (editable parameter)

- TS id:

In this field the Transport Stream identifier must be set. (editable

parameter)

- Network id:

In this option the network identifier must be specified. (editable

parameter)

83 HEN-70_H.264 Encoder USER’S MANUAL V5.6

- Network Name:

Specify the name of the network. (editable parameter)

- Service Name:

Set the name of the service. (editable parameter)

5.2.1.5 Output

- TS Bitrate: Select the desired bitrate (editable parameter)

When editable parameters are being set in the Web Server and new

values are being introduced, the text remains in red colour until the enter button is pressed. When the enter button is pressed, the new values are saved and the text will appear in black colour. It is

necessary to press the enter button to keep and save the new values on the screen.

84 HEN-70_H.264 Encoder USER’S MANUAL V5.6

5.2.2 TSoIP

Figure 5.11 Web Server TSoIP (IP Output) screen

- Local Address: Configure the IP address of the device which is going to send the

information. (editable parameter)

- Subnet:

Configure the Subnet address of the device which is going to send the information. (editable parameter)

- Gateway:

Configure the Gateway address of the device which is going to send the information. (editable parameter)

85 HEN-70_H.264 Encoder USER’S MANUAL V5.6

5.2.2.1 IP Output

- FEC:

In this field the Forward Error Correction can be enabled or disabled. In case it is enabled, the number of columns and rows can be configured. If FEC option is enabled then, the only protocol which can

be used is RTP. (eligible parameter)

- Destination address: In this option, the IP of the device to which data is sent must be

configured. In case it is wanted to send data to a multicast address just enter the desired multicast address. (editable parameter)

- UDP Port:

In this option, the IP of the device to which data is sent must be configured. (editable parameter)

- TP per IP:

In this field the number of Transport Stream packets per IP (from 1 to 7) can be configured. (editable parameter)

- Protocol:

In this field the type of protocol used for the communication is selected. The type of protocol used for the communication can be RTP

or UDP. (eligible parameter)

- Time To Live[0..255]: This field limits the lifetime of data. The Time to Live value (from 1 to

255) means the number of routers that a packet can reach until that packet is discarded. (editable parameter)

When editable parameters are being set in the Web Server and new

values are being introduced, the text remains in red colour until the

enter button is pressed. When the enter button is pressed, the new values are saved and the text will appear in black colour. It is

necessary to press the enter button to keep and save the new values on the screen.

86 HEN-70_H.264 Encoder USER’S MANUAL V5.6

5.2.2.2 IP Input

Figure 5.12 Web Server TSoIP (IP Input) screen

- Local Address: Configure the IP address of the device which is going to send the

information. (editable parameter)

- Subnet: Configure the Subnet address of the device which is going to send the

information. (editable parameter)

- Gateway: Configure the Gateway address of the device which is going to send

the information. (editable parameter)

87 HEN-70_H.264 Encoder USER’S MANUAL V5.6

5.2.2.3 IP Input

- Addressing:

In this field it is configured if the IP received packets come from a unicast address or from a multicast address. (eligible parameter)

- Multicast address:

In this field the multicast address must be specified so as to receive the information properly. (editable parameter)

- FEC:

In this option the FEC option can be enabled or disabled. In case the enable option is selected, as the IP Forward Error Correction is

composed by a number of FEC columns and rows, it is shown the number of FEC columns and rows of the received signal. (eligible

parameter)

- UDP Port:

This field must be filled in with the port number of the device through

which is going to receive the signal. (editable parameter)

- Output Delay:

This delay means the time passed between the Transport Stream is

obtained in the decoder and the signal is taken out from the decoder. (editable parameter)

- Status:

In this field the status of the IP input is displayed. (reading parameter)

- BitRate:

In this field, the bitrate of the received signal is shown. (reading parameter)

- Packet Size:

In this field, the size in bytes of the IP received packet is displayed. (reading parameter)

- TP per IP:

In this option the number of Transport Stream packets per IP packet is displayed. (reading parameter)

88 HEN-70_H.264 Encoder USER’S MANUAL V5.6

- Protocol:

In this field the protocol used for the communication is displayed. Two protocols are possible: UDP or RTP. (reading parameter)

- PCR Present: Program Clock Reference. To enable a decoder to present

synchronized content, such as audio tracks matching the associated video, at least once each 100 ms a Program Clock Reference, or PCR is transmitted in the adaptation field of an MPEG-2 transport stream

packet. The parameters displayed can be present or no present. (reading parameter)

When editable parameters are being set in the Web Server and new

values are being introduced, the text remains in red colour until the

enter button is pressed. When the enter button is pressed, the new values are saved and the text will appear in black colour. It is

necessary to press the enter button to keep and save the new values on the screen.

89 HEN-70_H.264 Encoder USER’S MANUAL V5.6

5.2.3 CA-BISS

Figure 5.13 Web Server CA-BISS screen

- BISS Mode:

Select the BISS encryption mode. (eligible parameter)

- Session Word:

Key for BISS-1 and BISS-E. The values of each characer introduced

can be from 0 to 9 and from A to F. (editable parameter)

- User ID:

User ID for BISS-E. The values of each characer introduced can be

from 0 to 9 and from A to F. (editable parameter)

When editable parameters are being set in the Web Server and new

values are being introduced, the text remains in red colour until the enter button is pressed. When the enter button is pressed, the new

values are saved and the text will appear in black colour. It is necessary to press the enter button to keep and save the new values on the screen.

90 HEN-70_H.264 Encoder USER’S MANUAL V5.6

5.2.4 UNIT

Figure 5.14 Web Server UNIT screen

5.2.4.1 LEDs Status (reading parameters)

- ON/OFF:

o If the Led is off the equipment is not being fed.

o The Led lights up in green when the equipment is turned on.

- ALARM:

o The LED lights up in red when any alarm occurs.

o The different alarms that can appear are: Voltage High.

Voltage Low. Temperature High.

91 HEN-70_H.264 Encoder USER’S MANUAL V5.6

o The different warnings that can appear are: No Video Input.

No GPS.

- STATUS:

The LED lights up when a change in the configuration of the device is

being processed.

5.2.4.2 Alarms (reading parameter)

In this option, different alarms which are present in the device are shown. The different alarms that can appear are:

- Voltage High. - Voltage Low.

- Temperature High. The different warnings that can appear are:

- No Video Input. - No GPS.

5.2.4.3 Configuration

- Web&SNMP Address

In this option it can be set the IP address of the device in case it is wanted to control the device remotely. So as to change the IP

address, introduce the desired number and then press enter button to save the introduced value. (editable parameter)

- Web&SNMP Subnet

Here, the Subnet Mask address of the device can be written. So as to change the Subnet Mask address, introduce the desired value and

then press enter button to save it. (editable parameter)

- Web&SNMP Gateway

In this option, the address of the Gateway must be written. So as to

change the Gateway address, introduce the desired value and then press enter button to save it. (editable parameter)

- Web&SNMP MAC

In this option the MAC address of the device is shown. (reading parameter)

92 HEN-70_H.264 Encoder USER’S MANUAL V5.6

- Standby Mode

In this option the user can turn on or turn off the device pressing On or Standby options. (elegible parameters)

- Night Mode:

If the night mode is OFF then, the light in the screen will shine more than if the night mode is ON. (eligible parameter)

- Admin Password

In this field, the administrator’s password is introduced. It can be set an own password which is a list of 8 digits. Then, to save the

introduced value, press Enter button. Moreover, there is the option to restore the default administrator password (00000000). (editable parameter)

- User Password

In this field, the user’s password is introduced. It can be set an own password which is a list of 8 digits. Then, to save the introduced

value, press Enter button. Moreover, there is the option to restore the default user password (00000000). (editable parameter)

5.2.4.4 Monitor

- Voltage:

In this field, the voltage of the device is shown. (reading parameter)

- Temperature:

In this field, the internal temperature of the device is displayed. (reading parameter)

- S/N:

In this field, the serial number of the device is displayed. (reading parameter)

- Firmware:

In this field, the number of the version installed in the device is displayed. (reading parameter)

- Model:

In this field, the model of the device is displayed. (reading parameter)

93 HEN-70_H.264 Encoder USER’S MANUAL V5.6

When editable parameters are being set in the Web Server and new

values are being introduced, the text remains in red colour until the

enter button is pressed. When the enter button is pressed, the new values are saved and the text will appear in black colour. It is necessary to press the enter button to keep and save the new values

on the screen.

94 HEN-70_H.264 Encoder USER’S MANUAL V5.6

5.3 Web Page Setup Notes In order for the data to be refreshed correctly, you may need to change some settings on your browser.

Please follow these instructions carefully.

For Google Chrome:

1. Make click in the Chrome menu situated in the toolbar of the browser.

2. Select tools. 3. Choose the option Delete navigation data… 4. Choose the option empty cache.

5. Make click in Delete navigation data.

For Internet Explorer:

1. From the Tools menu, select Internet Options 2. In the General tab, click the Settings button in the Browsing History section.

3. Select 'Every time I visit the webpage' then click the OK button. 4. Click the OK button

For Mozilla Firefox:

1. Open a new tab, in the address bar enter about:config 2. In the Filter box, enter disk

3. Set the value for 'browser.cache.disk.enable' to false (double click to change the setting). 4. Close the about:config tab.

5.4 SNMP Simple Network Management Protocol (SNMP) is an "Internet-standard protocol for managing devices on IP networks. SNMP exposes management

data in the form of variables on the managed systems, which describe the system configuration. These variables can then be queried (and sometimes

set) by managing applications. SNMP is an application-layer protocol and it runs over UDP at the transport

level. SNMP is based on a manager / agent model as it is shown below:

95 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Figure 5.15 SNMP management system

The SNMP agent used is MIB-II compliant. The SVP MIB (Management

Information Database) provides a standard representation of the SNMP Agent’s available information and where it is stored. The MIB is defined according to the ASN.1.

5.4.1 SNMP commands

SNMP use the next commands:

Operation Description Sender

Get

Readout the current value

of specific objects in the

MIB.

NMS

Get next

Readout the current value

of the next object in the

MIB.

NMS

Set

Change a value of a

specific object in the MIB.

NMS

Get response

Responds to a get, get

next or set request.

Agent

Trap

A trap is a mechanism to

trigger the NMS that a

change in the device has

occurred.

After receiving the trap

the NMS still has to poll

the device to find out the

details of the change.

Agent

Table 5.1 SNMP commands

Network Management Station SNMP agent

96 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Chapter 6: Equipment Installation

6.1 Introduction This chapter provides important information for encoder system installation such as connections available in the rear panel of the HEN-70 encoder and

their pinout, connectors needed and the accessories which are available with the encoder device.

6.2 Connections Every connection of the HEN-70 encoder is on the rear panel.

All the Lemo part numbers and pinout refer to the connector that is fixed to

the cable. The pinout of the cable connector is shown as if it is watched

from the soldering side.

All the input/output connections of the encoder are shown in the figure below:

Figure 6.1 HEN-70 Connections

The following figures show the HEN-70 front and rear panel. Connections mentioned in the upper figure are shown below.

Figure 6.2 HEN-70 front panel

HEN-70 Encoder

SDI (3G/SD/HD)

HDMI

Ethernet

Audio 1 (L&R)

Audio 2 (L&R)

TS over IP OUT

Power DC & AC

USB

DATA/GPS

ASI OUT AES/ABU

TS over IP IN

ASI IN

CVBS

97 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Figure 6.3 HEN-70 rear panel

The technical features of each connection are described on the following

sections.

98 HEN-70_H.264 Encoder USER’S MANUAL V5.6

6.2.1 Power supply

In this section, technical features about the power supply connections available and the connectors needed are described.

In all the Lemo connectors, the pin number one is circled and the

succeeding pins are in counter clockwise order.

AC Power supply

The encoder equipment can be powered by an AC source between 100 and 240V, or a DC source from 8 to 36 V.

The main frequency should be between 50 and 60 Hz.

The AC mains input uses a Neutrik MLC connector. A cable with the required connectors is supplied with the equipment. The AC power connector used in

this equipment is designed to prevent accidental disconnection. To extract the connector, pull back the locking clip and rotate the connector, as

indicated on the connector itself.

Power supply AC connection technical features

Item Features

Connector label POWER A.C.

Connector type MLC Neutrik

Supply voltage 100-240 V. (50/60Hz)

Table 6.1 AC Power supply features

Pinout

99 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Pin Description

1 L

2 GND

3 N

Table 6.2 AC Power supply connector pinout

Connector needed

DC Power supply

The encoder equipment can be powered by a DC source from 8 to 36 V. The DC power supply is connected via a Neutrik 4-pin male XLR connector

with a safety clip to prevent accidental disconnection.

Power supply DC connection technical features

Item Features

Connector label POWER D.C.

Conector type XLR-4 male

Supply voltage 8-36 V.

Table 6.3 DC Power supply features

NAC3FCA

NAC3MPA

100 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Pinout

Pin Description

1 GND

2 GND

3 VCC

4 VCC

Table 6.4 DC Power supply connector pinout

Connector needed

The DC power supply is connected via a Neutrik 4-pin male XLR connector with a safety clip to prevent accidental disconnection.

101 HEN-70_H.264 Encoder USER’S MANUAL V5.6

6.2.2 ASI

ASI input

The HEN-70 encoder has a DVB-ASI Transport Stream input, available on

an insulated 75 Ω BNC connector.

ASI IN connection technical features

Item Features

Connector label ASI-IN

Connector type Female BNC

Impedance 75 Ω

Standard EN50083-9

Maximum Bitrate 216 Mbps

Table 6.5 DVB-ASI Transport Stream input connection features

ASI output

ASI output signal type uses 75Ω BNC connector. This connector is placed on the HEN-70 encoder rear panel.

It is important that 75 Ω connectors are used. This is because the female

output connector of the HEN-70 unit may be damaged and because of an impedance mismatch.

ASI connection technical features

Item Features

Connector label ASI-OUT

Connector type BNC female

Impedance 75 Ω

Standard EN50083-9

Maximum Bitrate 100 Mbit/s

Table 6.6 DVB-ASI Transport Stream output connection features

102 HEN-70_H.264 Encoder USER’S MANUAL V5.6

6.2.3 CVBS/ SDI/ HDMI

The HEN-70 encoder and modulator incorporates an HDMI input so as to allow that new devices can be connected.

SD-SDI digital video input is compatible with SMPTE-259 Standard, HD-SDI digital video input signal type is SMPTE-292 compliant and 3G-SDI digital

video input signal type is SMPTE-425M compliant. In chapter 3: HEN-70 Menus and Operation, it is explained in detail how to

choose the input video signal type, CVBS, HDMI, digital video SDI signal or DVB-ASI Transport Stream signal.

CVBS connection technical features

Item Features

Connector Label CVBS

Connector type Female BNC

Impedance 75 Ω

Table 6.7 CVBS signal connection features

SDI connection technical features

Item Features

Connector Label SDI

Connector type Female BNC

Impedance 75 Ω

Input Level 800 mVpp nominal ±10%

Standards SMPTE-259M and SMPTE-272M

SMPTE-292M and SMPTE-299M

SMPTE-425M

Bitrate SD: 270 Mbit/s

HD: 1485 Mbit/s

3G: 3 Gbit/s

Table 6.8 SDI input signal connection features

HDMI connection technical features

Item Features

Connector Label HDMI

Connector type Type A

Table 6.9 HDMI input signal connection features

103 HEN-70_H.264 Encoder USER’S MANUAL V5.6

6.2.4 Transport Stream over IP

Transport Stream over IP Input and Output

The HEN-70 encoder has a connector that allows receiving and transporting video over IP. The connector is an UTP Cat 5e which is described in the

EIA/TIA568B standard.

TS over IP connection technical features

Item Features

Connector Label VIDEO over IP

Connector type RJ-45

Table 6.10 Transport stream over IP input connection technical features

There is no recompression when the equipment sends the information through IP. At the level of ASI and IP, the device keeps the original coding

generated in the transmitter.

Transport Stream over IP gives some benefits like:

Ensured Quality of Service with highly reliable Video Gateways.

Built-in intelligent monitoring and redundancy solutions.

Simple and fast connection setup and teardown with T-VIPS Connect.

Allows broadcasters and network operators to simplify their day to day

operation.

Create revenue-generating professional Wide Area Networks for video

transport.

Technical features are described below:

IP encapsulation and 2D FEC encoding and decoding as defined in SMPTE 2022.

Persistent storage of configuration parameters. Unicast and multicast IP addressing.

It is not possible to configure the equipment as IP input and IP output at

the same time.

104 HEN-70_H.264 Encoder USER’S MANUAL V5.6

6.2.5 Audio inputs

The HEN-70 encoder has four possible audio inputs:

2 audio inputs to insert 2 AES/EBU stereo channels, 2 stereo or 4

mono analogue (mic phantom, mic dynamic and line) signals where connections are made using two 5 pin Lemo 0B connectors on

equipment rear panel.

1 input to insert either 4 audio channels embedded on a SDI signal

where connections are made with a BNC connector on equipment rear panel.

1 HDMI input to insert HDMI embedded audio signals where

connections are made with a HDMI connector on equipment rear panel.

Embedded audio signals must be compliant with SMPTE-272M standard

when embedded on SD-SDI video signal, SMPTE-299M standard when embedded on HD-SDI video signal and with SMPTE-424 when embedded on 3G-SDI signal.

AES/EBU and analogue audio input technical features

Item Features

Audio channel number 4

Connector labels AUDIO 1

AUDIO 2

Connector type 5 pin Lemo 0B

Cable connector part number FGG.0B.305.CLAZ

Manufacturer Lemo

Table 6.11 AES/EBU and analogue audio input connection technical features

105 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Pinout of the cable connector (Watched from the soldering side)

Pin Description

1 A1L+ / AES1

2 A1L- / AES1N

3 GND

4 A1R+

5 A1R-

Table 6.12 AES/EBU and analogue audio cable connector pinout

2 5

3 4

1

106 HEN-70_H.264 Encoder USER’S MANUAL V5.6

6.2.6 Data/GPS input

This input is mainly used in order to transfer GPS data or user data through connections made using 6 pin Lemo 0B connector on equipment rear panel. Thanks to this characteristic it is possible to obtain GPS coordinates in the

HEN-70 encoder, know the exact position of the encoder and the distance between the receiver and the encoder as well as other parameters.

Data/GPS connection technical features

Item Features

Connector Label Data/GPS

Connector type 6 pin Lemo 0B

Cable connector part number FGG.0B.306.CLAZ

Manufacturer Lemo

Table 6.13 Data/GPS input connection technical features

Pinout of the cable connector (Watched from the soldering side)

Pin Description

1 Ground

2 DATA

3 NOT USED

4 +5Vd_GPS

5 PA_ON/OFF

6 PA_DIRECT

Table 6.14 Data/GPS cable connector pinout

1

3

2

4

5

6

107 HEN-70_H.264 Encoder USER’S MANUAL V5.6

6.2.7 USB connection

Thanks to the USB connection, it is possible to update directly from an external USB device the firmware of the HEN-70 encoder. The connector is type A.

USB connection technical features

Item Features

Connector Label USB

Connector type Type A

Table 6.15 USB connection technical features

6.2.8 Ethernet

This connection allows the user to monitor and setup any parameter of the

encoder throughout Web Browser and SNMP through the network. The connector used is a RJ-45.

Ethernet connection technical features

Item Features

Connector Label Ethernet

Connector type RJ-45

Table 6.16 Ethernet input connection technical features

108 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Glossary

AES/EBU

Audio Engineering Society/European

Broadcasting Union

ACPR

Adjacent Channel Power Ratio

APSK

Amplitude and phase-shift keying or asymmetric phase-shift

keying (APSK)

ASI

Asynchronous Serial Interface

BNC

Bayonet Neill-Concelman

BR

BitRate

CA-BISS

Conditional Access-BISS

COFDM

Coded Orthogonal Frequency

Division Multiplexing

DC

Direct current

DVB-S2

Digital Video Broadcasting by

Satellite – Second Generation

DVB-T

Digital Video Broadcasting –

Terrestrial

DVB-T2

Digital Video Broadcasting –

Terrestrial Second Generation

ETSI

European Telecommunications Standards Institute

109 HEN-70_H.264 Encoder USER’S MANUAL V5.6

EVM

Error Vector Magnitude

FEC

Forward Error Correction

FFT

Fast Fourier transform

GPS

Global Positioning System

HD

High Definition

HDMI

High-Definition Multimedia Interface

HDR

High Definition Receiver

HDT

High Definition Transmitter

IF

Intermediate Frequency

IG

Interval Guard

IP

Internet Protocol

LCD

Liquid Crystal Display

LED

Light-Emitting Diode

LD

Low Delay

MPEG

Moving Picture Experts Group

NLOS

Non Line of Sight

110 HEN-70_H.264 Encoder USER’S MANUAL V5.6

PAL PAL

PID

Packet Identification

QAM

Quadrature Amplitude Modulation

QPSK

Quadrature Phase-Shift Keying

RF

RadioFrequency

RTC

Remote Control

SD

Standard Delay

SDI

Serial Digital Interface

SNMP

Simple Network Management

Protocol

TFT

Thin-Film Transistor

TS

Transport Stream

UDP

User Datagram Protocol

USB

Universal Serial Bus

111 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Notes

112 HEN-70_H.264 Encoder USER’S MANUAL V5.6

Final note

SVP Broadcast Microwave S.L. is constantly striving to improve all of its products.

Therefore, we ask you to understand that modifications may occur in

designs, equipment and technology. Consequently, no responsibility can be derived from the information, illustrations or descriptions contained in this manual.

The texts, illustrations and instructions in the manual are based on the

existing situation when the manual is published.

Reprinting, reproduction and translation, in part or in whole,

is forbidden without written authorisation from SVP Broadcast

Microwave S.L. SVP Broadcast Microwave reserves all rights regarding intellectual property

rights.

All rights reserved regarding modifications.

SVP Broadcast Microwave reserves the right to make changes to this manual and to the equipment without prior notice.

C/ Zubiaurre 7 bajo

48215 Iurreta Vizcaya – Spain

Tel: (+34) 94620 3722