RAN15 0 Documentation Improvements
-
Upload
independent -
Category
Documents
-
view
0 -
download
0
Transcript of RAN15 0 Documentation Improvements
wwwhuaweicom
RAN150 Documentation Improvements
Documentation Dept WN
2013-04
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Page 3
RAN150
New NodeB Baseband
Resource Management
New License Control Item Lists
Improved Move Feature
Activation Guide to Feature
Parameter Description
Improved Engineer guidelines
Feature
Documentation Troubleshooting
(Alarm Reference)
New (Alarm Reference) Introduction
Common Alarm Handling Actions
Common methods of collecting fault
information
New Handling flowchart
Improved More detailed operation
steps
Improved ldquoAlarm Descriptionrdquo section
New CME configuration guide
New Add configuration
scenarios in Reconfiguration
Guide
Configuration
Guide Documentation
obtain method
New Method of Obtaining
Product Documentation on
LMTM2000
Overview
Content
1 Overview
2 New Obtain Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Add the Method of Obtaining Product Documentation on
LMTM2000
M2000
LMT
On LMT and M2000 you can get the information of downloading documentation packages of the
corresponding product version
1 Get the documentation list
LMT Choose Obtain Documentation List
M2000 Choose Help gt Obtain
Documentation
2 Export hdxi file
LMT Click Export to export the hdxi file
M2000 Click Export Selected or Export All
to export the hdxi file
3 Download the documentation
Double click thehdxi file to download the
documentation to your HedEx Lite
You can also search the documentation in
httpsupporthuaweicom according to the
documentation list and then download them
Page 5
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Feature Documentation Improvement
Improvement Benefit
New NodeB Baseband Resource
Management
You can do NodeB baseband resource dimensioning and
configuration based on the provided principle and engineering
guidelines
New Add ldquoLicense Control Item Listsrdquo You can find the license control item IDname mapping
relationship with features
Improved Move Feature Activation Guide
to the Engineering Guidelines section of
feature parameter description
You can find one-stop engineering information in Engineering
Guidelines section
Improved Optimize the engineer guidelines
of 30+ feature parameter description
including MOCN IP RAN HSDPA HSUPA
Load Control etc
You can find detailed guide of the requirements and information
to be collected before deployment feature activation
observation and performance monitoring
Move Feature Activation Guide to Feature Parameter
Description
VOC Full E2E documentation for implementation of new feature (solution deployment guide with recommendation
problems MML commands and influence on the parameters counters etc)
Page 8
BSC6900 Product Documentation Feature Documentation
Action Move Feature Activation Guide to the Engineering Guidelines section of FPD
Benefit The Engineering Guidelines section of FPD now provides one-stop engineering information
New NodeB Baseband Resource Management
Description
Describe what are the baseband resources
and its consumption principles of NodeB the
configuration of baseband board and the
engineering guidelines of NodeB baseband
resource
Benefit
This document enables customers to know the
principle of baseband resource dimensioning
and configuration
Page 9
VOC We need to be clear adding picture and example to clarify the message regarding resource group
Other Feature Documentation Improvements
Page 10
Optimize the engineer guidelines (for 30+ FPDs) Add ldquoLicense Control Item Listsrdquo
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Alarm Reference improvements
Improvement Benefit
New Add (Alarm Reference) ldquoIntroductionrdquo You can get the guide of using Alarm Reference
New Add ldquoCommon Alarm Handling
Actionsrdquo
You can get common fault location methods and
troubleshooting methods which may extend your idea of
handling alarms
New Add ldquoCommon methods of collecting
fault informationrdquo
You can collect fault information before contacting Huawei if the
alarm is not cleared
bullNew Add flowcharts of handling
procedure
bull Improved Optimize more detailed
operation steps
Different users can find guidelines adapted to their levels
bull Experienced maintenance engineer can handle alarms by
referring only to the alarm handling flowcharts or stem steps
bull Newcomers can handle alarms by referring to step-by-step
instructions
bull Improved Separate the procedures for
ldquoRemote Handlingrdquo and ldquoOnsite Handlingrdquo
bullNew Add ldquoOnsite Preparationrdquo before
ldquoOnsite Handlingrdquo
The engineers can know what spare parts and tools they
should carry for onsite handling
Improved Optimize the description of
ldquoAlarm Descriptionrdquo section for RNC
(TOP20) and NodeB (TOP35) alarms
You can get detailed information about the alarm such as the
mechanism why the alarm reported the impact to the network
etc
Page 12
Alarm Reference improvements 12
Add flowcharts of remote handling and onsite
handling
Add (Alarm Reference) ldquoIntroductionrdquo ldquoCommon
Alarm Handling Actionsrdquo ldquoCommon methods of
collecting fault informationrdquo
Note
The collect fault information method is in the ldquoCollect
informationrdquo section in 3900 Series Base Station Alarm
Reference
New
Page 13
Alarm Reference improvements 22
Separate the procedures for ldquoRemote
Handlingrdquo and ldquoOnsite Handlingrdquo
Optimize the description of ldquoAlarm Descriptionrdquo
section
Note
The optimization is for RNC (TOP20) and NodeB (TOP35) alarms
TOP alarms are the ones reported with high frequency and complex
to deal with
RAN140
RAN150
Page 14
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Page 3
RAN150
New NodeB Baseband
Resource Management
New License Control Item Lists
Improved Move Feature
Activation Guide to Feature
Parameter Description
Improved Engineer guidelines
Feature
Documentation Troubleshooting
(Alarm Reference)
New (Alarm Reference) Introduction
Common Alarm Handling Actions
Common methods of collecting fault
information
New Handling flowchart
Improved More detailed operation
steps
Improved ldquoAlarm Descriptionrdquo section
New CME configuration guide
New Add configuration
scenarios in Reconfiguration
Guide
Configuration
Guide Documentation
obtain method
New Method of Obtaining
Product Documentation on
LMTM2000
Overview
Content
1 Overview
2 New Obtain Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Add the Method of Obtaining Product Documentation on
LMTM2000
M2000
LMT
On LMT and M2000 you can get the information of downloading documentation packages of the
corresponding product version
1 Get the documentation list
LMT Choose Obtain Documentation List
M2000 Choose Help gt Obtain
Documentation
2 Export hdxi file
LMT Click Export to export the hdxi file
M2000 Click Export Selected or Export All
to export the hdxi file
3 Download the documentation
Double click thehdxi file to download the
documentation to your HedEx Lite
You can also search the documentation in
httpsupporthuaweicom according to the
documentation list and then download them
Page 5
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Feature Documentation Improvement
Improvement Benefit
New NodeB Baseband Resource
Management
You can do NodeB baseband resource dimensioning and
configuration based on the provided principle and engineering
guidelines
New Add ldquoLicense Control Item Listsrdquo You can find the license control item IDname mapping
relationship with features
Improved Move Feature Activation Guide
to the Engineering Guidelines section of
feature parameter description
You can find one-stop engineering information in Engineering
Guidelines section
Improved Optimize the engineer guidelines
of 30+ feature parameter description
including MOCN IP RAN HSDPA HSUPA
Load Control etc
You can find detailed guide of the requirements and information
to be collected before deployment feature activation
observation and performance monitoring
Move Feature Activation Guide to Feature Parameter
Description
VOC Full E2E documentation for implementation of new feature (solution deployment guide with recommendation
problems MML commands and influence on the parameters counters etc)
Page 8
BSC6900 Product Documentation Feature Documentation
Action Move Feature Activation Guide to the Engineering Guidelines section of FPD
Benefit The Engineering Guidelines section of FPD now provides one-stop engineering information
New NodeB Baseband Resource Management
Description
Describe what are the baseband resources
and its consumption principles of NodeB the
configuration of baseband board and the
engineering guidelines of NodeB baseband
resource
Benefit
This document enables customers to know the
principle of baseband resource dimensioning
and configuration
Page 9
VOC We need to be clear adding picture and example to clarify the message regarding resource group
Other Feature Documentation Improvements
Page 10
Optimize the engineer guidelines (for 30+ FPDs) Add ldquoLicense Control Item Listsrdquo
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Alarm Reference improvements
Improvement Benefit
New Add (Alarm Reference) ldquoIntroductionrdquo You can get the guide of using Alarm Reference
New Add ldquoCommon Alarm Handling
Actionsrdquo
You can get common fault location methods and
troubleshooting methods which may extend your idea of
handling alarms
New Add ldquoCommon methods of collecting
fault informationrdquo
You can collect fault information before contacting Huawei if the
alarm is not cleared
bullNew Add flowcharts of handling
procedure
bull Improved Optimize more detailed
operation steps
Different users can find guidelines adapted to their levels
bull Experienced maintenance engineer can handle alarms by
referring only to the alarm handling flowcharts or stem steps
bull Newcomers can handle alarms by referring to step-by-step
instructions
bull Improved Separate the procedures for
ldquoRemote Handlingrdquo and ldquoOnsite Handlingrdquo
bullNew Add ldquoOnsite Preparationrdquo before
ldquoOnsite Handlingrdquo
The engineers can know what spare parts and tools they
should carry for onsite handling
Improved Optimize the description of
ldquoAlarm Descriptionrdquo section for RNC
(TOP20) and NodeB (TOP35) alarms
You can get detailed information about the alarm such as the
mechanism why the alarm reported the impact to the network
etc
Page 12
Alarm Reference improvements 12
Add flowcharts of remote handling and onsite
handling
Add (Alarm Reference) ldquoIntroductionrdquo ldquoCommon
Alarm Handling Actionsrdquo ldquoCommon methods of
collecting fault informationrdquo
Note
The collect fault information method is in the ldquoCollect
informationrdquo section in 3900 Series Base Station Alarm
Reference
New
Page 13
Alarm Reference improvements 22
Separate the procedures for ldquoRemote
Handlingrdquo and ldquoOnsite Handlingrdquo
Optimize the description of ldquoAlarm Descriptionrdquo
section
Note
The optimization is for RNC (TOP20) and NodeB (TOP35) alarms
TOP alarms are the ones reported with high frequency and complex
to deal with
RAN140
RAN150
Page 14
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Page 3
RAN150
New NodeB Baseband
Resource Management
New License Control Item Lists
Improved Move Feature
Activation Guide to Feature
Parameter Description
Improved Engineer guidelines
Feature
Documentation Troubleshooting
(Alarm Reference)
New (Alarm Reference) Introduction
Common Alarm Handling Actions
Common methods of collecting fault
information
New Handling flowchart
Improved More detailed operation
steps
Improved ldquoAlarm Descriptionrdquo section
New CME configuration guide
New Add configuration
scenarios in Reconfiguration
Guide
Configuration
Guide Documentation
obtain method
New Method of Obtaining
Product Documentation on
LMTM2000
Overview
Content
1 Overview
2 New Obtain Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Add the Method of Obtaining Product Documentation on
LMTM2000
M2000
LMT
On LMT and M2000 you can get the information of downloading documentation packages of the
corresponding product version
1 Get the documentation list
LMT Choose Obtain Documentation List
M2000 Choose Help gt Obtain
Documentation
2 Export hdxi file
LMT Click Export to export the hdxi file
M2000 Click Export Selected or Export All
to export the hdxi file
3 Download the documentation
Double click thehdxi file to download the
documentation to your HedEx Lite
You can also search the documentation in
httpsupporthuaweicom according to the
documentation list and then download them
Page 5
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Feature Documentation Improvement
Improvement Benefit
New NodeB Baseband Resource
Management
You can do NodeB baseband resource dimensioning and
configuration based on the provided principle and engineering
guidelines
New Add ldquoLicense Control Item Listsrdquo You can find the license control item IDname mapping
relationship with features
Improved Move Feature Activation Guide
to the Engineering Guidelines section of
feature parameter description
You can find one-stop engineering information in Engineering
Guidelines section
Improved Optimize the engineer guidelines
of 30+ feature parameter description
including MOCN IP RAN HSDPA HSUPA
Load Control etc
You can find detailed guide of the requirements and information
to be collected before deployment feature activation
observation and performance monitoring
Move Feature Activation Guide to Feature Parameter
Description
VOC Full E2E documentation for implementation of new feature (solution deployment guide with recommendation
problems MML commands and influence on the parameters counters etc)
Page 8
BSC6900 Product Documentation Feature Documentation
Action Move Feature Activation Guide to the Engineering Guidelines section of FPD
Benefit The Engineering Guidelines section of FPD now provides one-stop engineering information
New NodeB Baseband Resource Management
Description
Describe what are the baseband resources
and its consumption principles of NodeB the
configuration of baseband board and the
engineering guidelines of NodeB baseband
resource
Benefit
This document enables customers to know the
principle of baseband resource dimensioning
and configuration
Page 9
VOC We need to be clear adding picture and example to clarify the message regarding resource group
Other Feature Documentation Improvements
Page 10
Optimize the engineer guidelines (for 30+ FPDs) Add ldquoLicense Control Item Listsrdquo
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Alarm Reference improvements
Improvement Benefit
New Add (Alarm Reference) ldquoIntroductionrdquo You can get the guide of using Alarm Reference
New Add ldquoCommon Alarm Handling
Actionsrdquo
You can get common fault location methods and
troubleshooting methods which may extend your idea of
handling alarms
New Add ldquoCommon methods of collecting
fault informationrdquo
You can collect fault information before contacting Huawei if the
alarm is not cleared
bullNew Add flowcharts of handling
procedure
bull Improved Optimize more detailed
operation steps
Different users can find guidelines adapted to their levels
bull Experienced maintenance engineer can handle alarms by
referring only to the alarm handling flowcharts or stem steps
bull Newcomers can handle alarms by referring to step-by-step
instructions
bull Improved Separate the procedures for
ldquoRemote Handlingrdquo and ldquoOnsite Handlingrdquo
bullNew Add ldquoOnsite Preparationrdquo before
ldquoOnsite Handlingrdquo
The engineers can know what spare parts and tools they
should carry for onsite handling
Improved Optimize the description of
ldquoAlarm Descriptionrdquo section for RNC
(TOP20) and NodeB (TOP35) alarms
You can get detailed information about the alarm such as the
mechanism why the alarm reported the impact to the network
etc
Page 12
Alarm Reference improvements 12
Add flowcharts of remote handling and onsite
handling
Add (Alarm Reference) ldquoIntroductionrdquo ldquoCommon
Alarm Handling Actionsrdquo ldquoCommon methods of
collecting fault informationrdquo
Note
The collect fault information method is in the ldquoCollect
informationrdquo section in 3900 Series Base Station Alarm
Reference
New
Page 13
Alarm Reference improvements 22
Separate the procedures for ldquoRemote
Handlingrdquo and ldquoOnsite Handlingrdquo
Optimize the description of ldquoAlarm Descriptionrdquo
section
Note
The optimization is for RNC (TOP20) and NodeB (TOP35) alarms
TOP alarms are the ones reported with high frequency and complex
to deal with
RAN140
RAN150
Page 14
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Content
1 Overview
2 New Obtain Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Add the Method of Obtaining Product Documentation on
LMTM2000
M2000
LMT
On LMT and M2000 you can get the information of downloading documentation packages of the
corresponding product version
1 Get the documentation list
LMT Choose Obtain Documentation List
M2000 Choose Help gt Obtain
Documentation
2 Export hdxi file
LMT Click Export to export the hdxi file
M2000 Click Export Selected or Export All
to export the hdxi file
3 Download the documentation
Double click thehdxi file to download the
documentation to your HedEx Lite
You can also search the documentation in
httpsupporthuaweicom according to the
documentation list and then download them
Page 5
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Feature Documentation Improvement
Improvement Benefit
New NodeB Baseband Resource
Management
You can do NodeB baseband resource dimensioning and
configuration based on the provided principle and engineering
guidelines
New Add ldquoLicense Control Item Listsrdquo You can find the license control item IDname mapping
relationship with features
Improved Move Feature Activation Guide
to the Engineering Guidelines section of
feature parameter description
You can find one-stop engineering information in Engineering
Guidelines section
Improved Optimize the engineer guidelines
of 30+ feature parameter description
including MOCN IP RAN HSDPA HSUPA
Load Control etc
You can find detailed guide of the requirements and information
to be collected before deployment feature activation
observation and performance monitoring
Move Feature Activation Guide to Feature Parameter
Description
VOC Full E2E documentation for implementation of new feature (solution deployment guide with recommendation
problems MML commands and influence on the parameters counters etc)
Page 8
BSC6900 Product Documentation Feature Documentation
Action Move Feature Activation Guide to the Engineering Guidelines section of FPD
Benefit The Engineering Guidelines section of FPD now provides one-stop engineering information
New NodeB Baseband Resource Management
Description
Describe what are the baseband resources
and its consumption principles of NodeB the
configuration of baseband board and the
engineering guidelines of NodeB baseband
resource
Benefit
This document enables customers to know the
principle of baseband resource dimensioning
and configuration
Page 9
VOC We need to be clear adding picture and example to clarify the message regarding resource group
Other Feature Documentation Improvements
Page 10
Optimize the engineer guidelines (for 30+ FPDs) Add ldquoLicense Control Item Listsrdquo
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Alarm Reference improvements
Improvement Benefit
New Add (Alarm Reference) ldquoIntroductionrdquo You can get the guide of using Alarm Reference
New Add ldquoCommon Alarm Handling
Actionsrdquo
You can get common fault location methods and
troubleshooting methods which may extend your idea of
handling alarms
New Add ldquoCommon methods of collecting
fault informationrdquo
You can collect fault information before contacting Huawei if the
alarm is not cleared
bullNew Add flowcharts of handling
procedure
bull Improved Optimize more detailed
operation steps
Different users can find guidelines adapted to their levels
bull Experienced maintenance engineer can handle alarms by
referring only to the alarm handling flowcharts or stem steps
bull Newcomers can handle alarms by referring to step-by-step
instructions
bull Improved Separate the procedures for
ldquoRemote Handlingrdquo and ldquoOnsite Handlingrdquo
bullNew Add ldquoOnsite Preparationrdquo before
ldquoOnsite Handlingrdquo
The engineers can know what spare parts and tools they
should carry for onsite handling
Improved Optimize the description of
ldquoAlarm Descriptionrdquo section for RNC
(TOP20) and NodeB (TOP35) alarms
You can get detailed information about the alarm such as the
mechanism why the alarm reported the impact to the network
etc
Page 12
Alarm Reference improvements 12
Add flowcharts of remote handling and onsite
handling
Add (Alarm Reference) ldquoIntroductionrdquo ldquoCommon
Alarm Handling Actionsrdquo ldquoCommon methods of
collecting fault informationrdquo
Note
The collect fault information method is in the ldquoCollect
informationrdquo section in 3900 Series Base Station Alarm
Reference
New
Page 13
Alarm Reference improvements 22
Separate the procedures for ldquoRemote
Handlingrdquo and ldquoOnsite Handlingrdquo
Optimize the description of ldquoAlarm Descriptionrdquo
section
Note
The optimization is for RNC (TOP20) and NodeB (TOP35) alarms
TOP alarms are the ones reported with high frequency and complex
to deal with
RAN140
RAN150
Page 14
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Add the Method of Obtaining Product Documentation on
LMTM2000
M2000
LMT
On LMT and M2000 you can get the information of downloading documentation packages of the
corresponding product version
1 Get the documentation list
LMT Choose Obtain Documentation List
M2000 Choose Help gt Obtain
Documentation
2 Export hdxi file
LMT Click Export to export the hdxi file
M2000 Click Export Selected or Export All
to export the hdxi file
3 Download the documentation
Double click thehdxi file to download the
documentation to your HedEx Lite
You can also search the documentation in
httpsupporthuaweicom according to the
documentation list and then download them
Page 5
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Feature Documentation Improvement
Improvement Benefit
New NodeB Baseband Resource
Management
You can do NodeB baseband resource dimensioning and
configuration based on the provided principle and engineering
guidelines
New Add ldquoLicense Control Item Listsrdquo You can find the license control item IDname mapping
relationship with features
Improved Move Feature Activation Guide
to the Engineering Guidelines section of
feature parameter description
You can find one-stop engineering information in Engineering
Guidelines section
Improved Optimize the engineer guidelines
of 30+ feature parameter description
including MOCN IP RAN HSDPA HSUPA
Load Control etc
You can find detailed guide of the requirements and information
to be collected before deployment feature activation
observation and performance monitoring
Move Feature Activation Guide to Feature Parameter
Description
VOC Full E2E documentation for implementation of new feature (solution deployment guide with recommendation
problems MML commands and influence on the parameters counters etc)
Page 8
BSC6900 Product Documentation Feature Documentation
Action Move Feature Activation Guide to the Engineering Guidelines section of FPD
Benefit The Engineering Guidelines section of FPD now provides one-stop engineering information
New NodeB Baseband Resource Management
Description
Describe what are the baseband resources
and its consumption principles of NodeB the
configuration of baseband board and the
engineering guidelines of NodeB baseband
resource
Benefit
This document enables customers to know the
principle of baseband resource dimensioning
and configuration
Page 9
VOC We need to be clear adding picture and example to clarify the message regarding resource group
Other Feature Documentation Improvements
Page 10
Optimize the engineer guidelines (for 30+ FPDs) Add ldquoLicense Control Item Listsrdquo
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Alarm Reference improvements
Improvement Benefit
New Add (Alarm Reference) ldquoIntroductionrdquo You can get the guide of using Alarm Reference
New Add ldquoCommon Alarm Handling
Actionsrdquo
You can get common fault location methods and
troubleshooting methods which may extend your idea of
handling alarms
New Add ldquoCommon methods of collecting
fault informationrdquo
You can collect fault information before contacting Huawei if the
alarm is not cleared
bullNew Add flowcharts of handling
procedure
bull Improved Optimize more detailed
operation steps
Different users can find guidelines adapted to their levels
bull Experienced maintenance engineer can handle alarms by
referring only to the alarm handling flowcharts or stem steps
bull Newcomers can handle alarms by referring to step-by-step
instructions
bull Improved Separate the procedures for
ldquoRemote Handlingrdquo and ldquoOnsite Handlingrdquo
bullNew Add ldquoOnsite Preparationrdquo before
ldquoOnsite Handlingrdquo
The engineers can know what spare parts and tools they
should carry for onsite handling
Improved Optimize the description of
ldquoAlarm Descriptionrdquo section for RNC
(TOP20) and NodeB (TOP35) alarms
You can get detailed information about the alarm such as the
mechanism why the alarm reported the impact to the network
etc
Page 12
Alarm Reference improvements 12
Add flowcharts of remote handling and onsite
handling
Add (Alarm Reference) ldquoIntroductionrdquo ldquoCommon
Alarm Handling Actionsrdquo ldquoCommon methods of
collecting fault informationrdquo
Note
The collect fault information method is in the ldquoCollect
informationrdquo section in 3900 Series Base Station Alarm
Reference
New
Page 13
Alarm Reference improvements 22
Separate the procedures for ldquoRemote
Handlingrdquo and ldquoOnsite Handlingrdquo
Optimize the description of ldquoAlarm Descriptionrdquo
section
Note
The optimization is for RNC (TOP20) and NodeB (TOP35) alarms
TOP alarms are the ones reported with high frequency and complex
to deal with
RAN140
RAN150
Page 14
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Feature Documentation Improvement
Improvement Benefit
New NodeB Baseband Resource
Management
You can do NodeB baseband resource dimensioning and
configuration based on the provided principle and engineering
guidelines
New Add ldquoLicense Control Item Listsrdquo You can find the license control item IDname mapping
relationship with features
Improved Move Feature Activation Guide
to the Engineering Guidelines section of
feature parameter description
You can find one-stop engineering information in Engineering
Guidelines section
Improved Optimize the engineer guidelines
of 30+ feature parameter description
including MOCN IP RAN HSDPA HSUPA
Load Control etc
You can find detailed guide of the requirements and information
to be collected before deployment feature activation
observation and performance monitoring
Move Feature Activation Guide to Feature Parameter
Description
VOC Full E2E documentation for implementation of new feature (solution deployment guide with recommendation
problems MML commands and influence on the parameters counters etc)
Page 8
BSC6900 Product Documentation Feature Documentation
Action Move Feature Activation Guide to the Engineering Guidelines section of FPD
Benefit The Engineering Guidelines section of FPD now provides one-stop engineering information
New NodeB Baseband Resource Management
Description
Describe what are the baseband resources
and its consumption principles of NodeB the
configuration of baseband board and the
engineering guidelines of NodeB baseband
resource
Benefit
This document enables customers to know the
principle of baseband resource dimensioning
and configuration
Page 9
VOC We need to be clear adding picture and example to clarify the message regarding resource group
Other Feature Documentation Improvements
Page 10
Optimize the engineer guidelines (for 30+ FPDs) Add ldquoLicense Control Item Listsrdquo
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Alarm Reference improvements
Improvement Benefit
New Add (Alarm Reference) ldquoIntroductionrdquo You can get the guide of using Alarm Reference
New Add ldquoCommon Alarm Handling
Actionsrdquo
You can get common fault location methods and
troubleshooting methods which may extend your idea of
handling alarms
New Add ldquoCommon methods of collecting
fault informationrdquo
You can collect fault information before contacting Huawei if the
alarm is not cleared
bullNew Add flowcharts of handling
procedure
bull Improved Optimize more detailed
operation steps
Different users can find guidelines adapted to their levels
bull Experienced maintenance engineer can handle alarms by
referring only to the alarm handling flowcharts or stem steps
bull Newcomers can handle alarms by referring to step-by-step
instructions
bull Improved Separate the procedures for
ldquoRemote Handlingrdquo and ldquoOnsite Handlingrdquo
bullNew Add ldquoOnsite Preparationrdquo before
ldquoOnsite Handlingrdquo
The engineers can know what spare parts and tools they
should carry for onsite handling
Improved Optimize the description of
ldquoAlarm Descriptionrdquo section for RNC
(TOP20) and NodeB (TOP35) alarms
You can get detailed information about the alarm such as the
mechanism why the alarm reported the impact to the network
etc
Page 12
Alarm Reference improvements 12
Add flowcharts of remote handling and onsite
handling
Add (Alarm Reference) ldquoIntroductionrdquo ldquoCommon
Alarm Handling Actionsrdquo ldquoCommon methods of
collecting fault informationrdquo
Note
The collect fault information method is in the ldquoCollect
informationrdquo section in 3900 Series Base Station Alarm
Reference
New
Page 13
Alarm Reference improvements 22
Separate the procedures for ldquoRemote
Handlingrdquo and ldquoOnsite Handlingrdquo
Optimize the description of ldquoAlarm Descriptionrdquo
section
Note
The optimization is for RNC (TOP20) and NodeB (TOP35) alarms
TOP alarms are the ones reported with high frequency and complex
to deal with
RAN140
RAN150
Page 14
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Overview of Feature Documentation Improvement
Improvement Benefit
New NodeB Baseband Resource
Management
You can do NodeB baseband resource dimensioning and
configuration based on the provided principle and engineering
guidelines
New Add ldquoLicense Control Item Listsrdquo You can find the license control item IDname mapping
relationship with features
Improved Move Feature Activation Guide
to the Engineering Guidelines section of
feature parameter description
You can find one-stop engineering information in Engineering
Guidelines section
Improved Optimize the engineer guidelines
of 30+ feature parameter description
including MOCN IP RAN HSDPA HSUPA
Load Control etc
You can find detailed guide of the requirements and information
to be collected before deployment feature activation
observation and performance monitoring
Move Feature Activation Guide to Feature Parameter
Description
VOC Full E2E documentation for implementation of new feature (solution deployment guide with recommendation
problems MML commands and influence on the parameters counters etc)
Page 8
BSC6900 Product Documentation Feature Documentation
Action Move Feature Activation Guide to the Engineering Guidelines section of FPD
Benefit The Engineering Guidelines section of FPD now provides one-stop engineering information
New NodeB Baseband Resource Management
Description
Describe what are the baseband resources
and its consumption principles of NodeB the
configuration of baseband board and the
engineering guidelines of NodeB baseband
resource
Benefit
This document enables customers to know the
principle of baseband resource dimensioning
and configuration
Page 9
VOC We need to be clear adding picture and example to clarify the message regarding resource group
Other Feature Documentation Improvements
Page 10
Optimize the engineer guidelines (for 30+ FPDs) Add ldquoLicense Control Item Listsrdquo
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Alarm Reference improvements
Improvement Benefit
New Add (Alarm Reference) ldquoIntroductionrdquo You can get the guide of using Alarm Reference
New Add ldquoCommon Alarm Handling
Actionsrdquo
You can get common fault location methods and
troubleshooting methods which may extend your idea of
handling alarms
New Add ldquoCommon methods of collecting
fault informationrdquo
You can collect fault information before contacting Huawei if the
alarm is not cleared
bullNew Add flowcharts of handling
procedure
bull Improved Optimize more detailed
operation steps
Different users can find guidelines adapted to their levels
bull Experienced maintenance engineer can handle alarms by
referring only to the alarm handling flowcharts or stem steps
bull Newcomers can handle alarms by referring to step-by-step
instructions
bull Improved Separate the procedures for
ldquoRemote Handlingrdquo and ldquoOnsite Handlingrdquo
bullNew Add ldquoOnsite Preparationrdquo before
ldquoOnsite Handlingrdquo
The engineers can know what spare parts and tools they
should carry for onsite handling
Improved Optimize the description of
ldquoAlarm Descriptionrdquo section for RNC
(TOP20) and NodeB (TOP35) alarms
You can get detailed information about the alarm such as the
mechanism why the alarm reported the impact to the network
etc
Page 12
Alarm Reference improvements 12
Add flowcharts of remote handling and onsite
handling
Add (Alarm Reference) ldquoIntroductionrdquo ldquoCommon
Alarm Handling Actionsrdquo ldquoCommon methods of
collecting fault informationrdquo
Note
The collect fault information method is in the ldquoCollect
informationrdquo section in 3900 Series Base Station Alarm
Reference
New
Page 13
Alarm Reference improvements 22
Separate the procedures for ldquoRemote
Handlingrdquo and ldquoOnsite Handlingrdquo
Optimize the description of ldquoAlarm Descriptionrdquo
section
Note
The optimization is for RNC (TOP20) and NodeB (TOP35) alarms
TOP alarms are the ones reported with high frequency and complex
to deal with
RAN140
RAN150
Page 14
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Move Feature Activation Guide to Feature Parameter
Description
VOC Full E2E documentation for implementation of new feature (solution deployment guide with recommendation
problems MML commands and influence on the parameters counters etc)
Page 8
BSC6900 Product Documentation Feature Documentation
Action Move Feature Activation Guide to the Engineering Guidelines section of FPD
Benefit The Engineering Guidelines section of FPD now provides one-stop engineering information
New NodeB Baseband Resource Management
Description
Describe what are the baseband resources
and its consumption principles of NodeB the
configuration of baseband board and the
engineering guidelines of NodeB baseband
resource
Benefit
This document enables customers to know the
principle of baseband resource dimensioning
and configuration
Page 9
VOC We need to be clear adding picture and example to clarify the message regarding resource group
Other Feature Documentation Improvements
Page 10
Optimize the engineer guidelines (for 30+ FPDs) Add ldquoLicense Control Item Listsrdquo
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Alarm Reference improvements
Improvement Benefit
New Add (Alarm Reference) ldquoIntroductionrdquo You can get the guide of using Alarm Reference
New Add ldquoCommon Alarm Handling
Actionsrdquo
You can get common fault location methods and
troubleshooting methods which may extend your idea of
handling alarms
New Add ldquoCommon methods of collecting
fault informationrdquo
You can collect fault information before contacting Huawei if the
alarm is not cleared
bullNew Add flowcharts of handling
procedure
bull Improved Optimize more detailed
operation steps
Different users can find guidelines adapted to their levels
bull Experienced maintenance engineer can handle alarms by
referring only to the alarm handling flowcharts or stem steps
bull Newcomers can handle alarms by referring to step-by-step
instructions
bull Improved Separate the procedures for
ldquoRemote Handlingrdquo and ldquoOnsite Handlingrdquo
bullNew Add ldquoOnsite Preparationrdquo before
ldquoOnsite Handlingrdquo
The engineers can know what spare parts and tools they
should carry for onsite handling
Improved Optimize the description of
ldquoAlarm Descriptionrdquo section for RNC
(TOP20) and NodeB (TOP35) alarms
You can get detailed information about the alarm such as the
mechanism why the alarm reported the impact to the network
etc
Page 12
Alarm Reference improvements 12
Add flowcharts of remote handling and onsite
handling
Add (Alarm Reference) ldquoIntroductionrdquo ldquoCommon
Alarm Handling Actionsrdquo ldquoCommon methods of
collecting fault informationrdquo
Note
The collect fault information method is in the ldquoCollect
informationrdquo section in 3900 Series Base Station Alarm
Reference
New
Page 13
Alarm Reference improvements 22
Separate the procedures for ldquoRemote
Handlingrdquo and ldquoOnsite Handlingrdquo
Optimize the description of ldquoAlarm Descriptionrdquo
section
Note
The optimization is for RNC (TOP20) and NodeB (TOP35) alarms
TOP alarms are the ones reported with high frequency and complex
to deal with
RAN140
RAN150
Page 14
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
New NodeB Baseband Resource Management
Description
Describe what are the baseband resources
and its consumption principles of NodeB the
configuration of baseband board and the
engineering guidelines of NodeB baseband
resource
Benefit
This document enables customers to know the
principle of baseband resource dimensioning
and configuration
Page 9
VOC We need to be clear adding picture and example to clarify the message regarding resource group
Other Feature Documentation Improvements
Page 10
Optimize the engineer guidelines (for 30+ FPDs) Add ldquoLicense Control Item Listsrdquo
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Alarm Reference improvements
Improvement Benefit
New Add (Alarm Reference) ldquoIntroductionrdquo You can get the guide of using Alarm Reference
New Add ldquoCommon Alarm Handling
Actionsrdquo
You can get common fault location methods and
troubleshooting methods which may extend your idea of
handling alarms
New Add ldquoCommon methods of collecting
fault informationrdquo
You can collect fault information before contacting Huawei if the
alarm is not cleared
bullNew Add flowcharts of handling
procedure
bull Improved Optimize more detailed
operation steps
Different users can find guidelines adapted to their levels
bull Experienced maintenance engineer can handle alarms by
referring only to the alarm handling flowcharts or stem steps
bull Newcomers can handle alarms by referring to step-by-step
instructions
bull Improved Separate the procedures for
ldquoRemote Handlingrdquo and ldquoOnsite Handlingrdquo
bullNew Add ldquoOnsite Preparationrdquo before
ldquoOnsite Handlingrdquo
The engineers can know what spare parts and tools they
should carry for onsite handling
Improved Optimize the description of
ldquoAlarm Descriptionrdquo section for RNC
(TOP20) and NodeB (TOP35) alarms
You can get detailed information about the alarm such as the
mechanism why the alarm reported the impact to the network
etc
Page 12
Alarm Reference improvements 12
Add flowcharts of remote handling and onsite
handling
Add (Alarm Reference) ldquoIntroductionrdquo ldquoCommon
Alarm Handling Actionsrdquo ldquoCommon methods of
collecting fault informationrdquo
Note
The collect fault information method is in the ldquoCollect
informationrdquo section in 3900 Series Base Station Alarm
Reference
New
Page 13
Alarm Reference improvements 22
Separate the procedures for ldquoRemote
Handlingrdquo and ldquoOnsite Handlingrdquo
Optimize the description of ldquoAlarm Descriptionrdquo
section
Note
The optimization is for RNC (TOP20) and NodeB (TOP35) alarms
TOP alarms are the ones reported with high frequency and complex
to deal with
RAN140
RAN150
Page 14
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Other Feature Documentation Improvements
Page 10
Optimize the engineer guidelines (for 30+ FPDs) Add ldquoLicense Control Item Listsrdquo
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Alarm Reference improvements
Improvement Benefit
New Add (Alarm Reference) ldquoIntroductionrdquo You can get the guide of using Alarm Reference
New Add ldquoCommon Alarm Handling
Actionsrdquo
You can get common fault location methods and
troubleshooting methods which may extend your idea of
handling alarms
New Add ldquoCommon methods of collecting
fault informationrdquo
You can collect fault information before contacting Huawei if the
alarm is not cleared
bullNew Add flowcharts of handling
procedure
bull Improved Optimize more detailed
operation steps
Different users can find guidelines adapted to their levels
bull Experienced maintenance engineer can handle alarms by
referring only to the alarm handling flowcharts or stem steps
bull Newcomers can handle alarms by referring to step-by-step
instructions
bull Improved Separate the procedures for
ldquoRemote Handlingrdquo and ldquoOnsite Handlingrdquo
bullNew Add ldquoOnsite Preparationrdquo before
ldquoOnsite Handlingrdquo
The engineers can know what spare parts and tools they
should carry for onsite handling
Improved Optimize the description of
ldquoAlarm Descriptionrdquo section for RNC
(TOP20) and NodeB (TOP35) alarms
You can get detailed information about the alarm such as the
mechanism why the alarm reported the impact to the network
etc
Page 12
Alarm Reference improvements 12
Add flowcharts of remote handling and onsite
handling
Add (Alarm Reference) ldquoIntroductionrdquo ldquoCommon
Alarm Handling Actionsrdquo ldquoCommon methods of
collecting fault informationrdquo
Note
The collect fault information method is in the ldquoCollect
informationrdquo section in 3900 Series Base Station Alarm
Reference
New
Page 13
Alarm Reference improvements 22
Separate the procedures for ldquoRemote
Handlingrdquo and ldquoOnsite Handlingrdquo
Optimize the description of ldquoAlarm Descriptionrdquo
section
Note
The optimization is for RNC (TOP20) and NodeB (TOP35) alarms
TOP alarms are the ones reported with high frequency and complex
to deal with
RAN140
RAN150
Page 14
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Alarm Reference improvements
Improvement Benefit
New Add (Alarm Reference) ldquoIntroductionrdquo You can get the guide of using Alarm Reference
New Add ldquoCommon Alarm Handling
Actionsrdquo
You can get common fault location methods and
troubleshooting methods which may extend your idea of
handling alarms
New Add ldquoCommon methods of collecting
fault informationrdquo
You can collect fault information before contacting Huawei if the
alarm is not cleared
bullNew Add flowcharts of handling
procedure
bull Improved Optimize more detailed
operation steps
Different users can find guidelines adapted to their levels
bull Experienced maintenance engineer can handle alarms by
referring only to the alarm handling flowcharts or stem steps
bull Newcomers can handle alarms by referring to step-by-step
instructions
bull Improved Separate the procedures for
ldquoRemote Handlingrdquo and ldquoOnsite Handlingrdquo
bullNew Add ldquoOnsite Preparationrdquo before
ldquoOnsite Handlingrdquo
The engineers can know what spare parts and tools they
should carry for onsite handling
Improved Optimize the description of
ldquoAlarm Descriptionrdquo section for RNC
(TOP20) and NodeB (TOP35) alarms
You can get detailed information about the alarm such as the
mechanism why the alarm reported the impact to the network
etc
Page 12
Alarm Reference improvements 12
Add flowcharts of remote handling and onsite
handling
Add (Alarm Reference) ldquoIntroductionrdquo ldquoCommon
Alarm Handling Actionsrdquo ldquoCommon methods of
collecting fault informationrdquo
Note
The collect fault information method is in the ldquoCollect
informationrdquo section in 3900 Series Base Station Alarm
Reference
New
Page 13
Alarm Reference improvements 22
Separate the procedures for ldquoRemote
Handlingrdquo and ldquoOnsite Handlingrdquo
Optimize the description of ldquoAlarm Descriptionrdquo
section
Note
The optimization is for RNC (TOP20) and NodeB (TOP35) alarms
TOP alarms are the ones reported with high frequency and complex
to deal with
RAN140
RAN150
Page 14
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Overview of Alarm Reference improvements
Improvement Benefit
New Add (Alarm Reference) ldquoIntroductionrdquo You can get the guide of using Alarm Reference
New Add ldquoCommon Alarm Handling
Actionsrdquo
You can get common fault location methods and
troubleshooting methods which may extend your idea of
handling alarms
New Add ldquoCommon methods of collecting
fault informationrdquo
You can collect fault information before contacting Huawei if the
alarm is not cleared
bullNew Add flowcharts of handling
procedure
bull Improved Optimize more detailed
operation steps
Different users can find guidelines adapted to their levels
bull Experienced maintenance engineer can handle alarms by
referring only to the alarm handling flowcharts or stem steps
bull Newcomers can handle alarms by referring to step-by-step
instructions
bull Improved Separate the procedures for
ldquoRemote Handlingrdquo and ldquoOnsite Handlingrdquo
bullNew Add ldquoOnsite Preparationrdquo before
ldquoOnsite Handlingrdquo
The engineers can know what spare parts and tools they
should carry for onsite handling
Improved Optimize the description of
ldquoAlarm Descriptionrdquo section for RNC
(TOP20) and NodeB (TOP35) alarms
You can get detailed information about the alarm such as the
mechanism why the alarm reported the impact to the network
etc
Page 12
Alarm Reference improvements 12
Add flowcharts of remote handling and onsite
handling
Add (Alarm Reference) ldquoIntroductionrdquo ldquoCommon
Alarm Handling Actionsrdquo ldquoCommon methods of
collecting fault informationrdquo
Note
The collect fault information method is in the ldquoCollect
informationrdquo section in 3900 Series Base Station Alarm
Reference
New
Page 13
Alarm Reference improvements 22
Separate the procedures for ldquoRemote
Handlingrdquo and ldquoOnsite Handlingrdquo
Optimize the description of ldquoAlarm Descriptionrdquo
section
Note
The optimization is for RNC (TOP20) and NodeB (TOP35) alarms
TOP alarms are the ones reported with high frequency and complex
to deal with
RAN140
RAN150
Page 14
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Alarm Reference improvements 12
Add flowcharts of remote handling and onsite
handling
Add (Alarm Reference) ldquoIntroductionrdquo ldquoCommon
Alarm Handling Actionsrdquo ldquoCommon methods of
collecting fault informationrdquo
Note
The collect fault information method is in the ldquoCollect
informationrdquo section in 3900 Series Base Station Alarm
Reference
New
Page 13
Alarm Reference improvements 22
Separate the procedures for ldquoRemote
Handlingrdquo and ldquoOnsite Handlingrdquo
Optimize the description of ldquoAlarm Descriptionrdquo
section
Note
The optimization is for RNC (TOP20) and NodeB (TOP35) alarms
TOP alarms are the ones reported with high frequency and complex
to deal with
RAN140
RAN150
Page 14
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Alarm Reference improvements 22
Separate the procedures for ldquoRemote
Handlingrdquo and ldquoOnsite Handlingrdquo
Optimize the description of ldquoAlarm Descriptionrdquo
section
Note
The optimization is for RNC (TOP20) and NodeB (TOP35) alarms
TOP alarms are the ones reported with high frequency and complex
to deal with
RAN140
RAN150
Page 14
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Overview of Configuration Guide improvements
Improvement Benefit
New CME configuration guide for feature
deployment (in FPD) Initial Configuration
and Reconfiguration Guide
You can find configuration guide both using MML command and
CME
New Add configuration scenarios in
Reconfiguration Guide
You can find the re configuration guide of Re-homing IuCS
Interface Expansion (IuCS) data Backup and restore for Rolling
back
Page 16
Configuration related documents include
Initial Configuration
Reconfiguration Guide
Feature Parameter Description (ldquoEngineering Guidelinesrdquo chapter)
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Both MML and CME configuration guide
In ldquoEngineering Guidelinesrdquo section of
Feature Parameter Description
In BSC6900BSC6910 Product Documentation
New
New
Page 17
VOC There is only MML command configuration guide without CME
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Add configuration scenarios in Reconfiguration Guide
Page 18
VOC Need the configuration guide of rolling back RNC rehoming and expansion
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Content
1 Overview
2 New Obtain Product Documentation on LMTM2000
3 Improved Feature Document
4 Improved Alarm Reference
5 Improved Configuration guide
6 Improved Disuse of ParameterCounterAlarmEvent
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Disuse of ParameterCounterAlarmEvent
VOC Lack the description of parameter disuse
Page 20
Action Add ldquoDisuse Statementrdquo description in
Reference
Reference changes
NBI (Northbound Interface) date documentation
NBI changes
Benefit Notice the disuse of parametercounteralarm so that you can plan ahead to avoid the impact to your
network
Example
Parameter Reference Parameter List (NBI data)
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Thank you wwwhuaweicom
One Documentation One Satisfaction
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22
Appendix
RAN150 Solution Changes Notice
Contact Huawei local engineer to get the RAN150 PCN
Wireless Documentation TopN Improvement
The 2013 wireless documentation TOPN Improvement includes
Capacity Monitoring Guide Improvement
Parameter Transparency Improvement
Hardware Specification Improvement
Delta Documentation Improvement
Feature Documentation Improvement
Troubleshooting Documentation Improvement
Counter Documentation Improvement
httpsupporthuaweicomsupportpagesnewsNewsInfoActiondodoc_id=IN0000056629ampcolID=ROOTENWE
B|CO0000003125ampactionFlag=view
Page 22