FLX-24 Installation manual R59770420/00 21/12/2009

Transcript of Print Preview - C:\Temp\.aptcache\ae2h0nj8/tf2h0xcy - Barco

FLX-24

Installation manual

R59770420/0021/12/2009

Barco Inc. Media and Entertainment Division11101 Trade Center Drive, Rancho Cordova, California 95670, USAPhone: +1 916 859-2500Fax: +1 916 859-2515E-mail: [email protected] us at the web: www.barco.com

Barco nv Media & Entertainment DivisionNoordlaan 5, B-8520 KuurnePhone: +32 56.36.82.11Fax: +32 56.36.883.86E-mail: [email protected] us at the web: www.barco.com

Printed in Belgium

ChangesBarco provides this manual ’as is’ without warranty of any kind, either expressed or implied, including but not limited to the implied war-ranties or merchantability and fitness for a particular purpose. Barco may make improvements and/or changes to the product(s) and/or theprogram(s) described in this publication at any time without notice.

This publication could contain technical inaccuracies or typographical errors. Changes are periodically made to the information in thispublication; these changes are incorporated in new editions of this publication.

Copyright ©All rights reserved. No part of this document may be copied, reproduced or translated. It shall not otherwise be recorded, transmitted orstored in a retrieval system without the prior written consent of Barco.

Disposal InformationThis equipment has required the extraction and use of natural resources for its production. It may contain hazardous substances for healthand environment. In order to avoid the dissemination of those substances in the environment and to diminish the pressure on naturalresources, we encourage you to use the appropriate take-back systems. Those systems will reuse or recycle most of the materials of yourend of life equipment in a sound way.

The crossed-out wheeled bin symbol invites you to use those systems. If you need more information on the collection, reuse and recyclingsystems, please contact your local or regional waste administrator. You can also contact us for more information on the environmentalperformances of our products.

Federal Communications Commission (FCC Statement)This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC rules.These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercialenvironment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance withthe instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area maycause harmful interference, in which case the user will be responsible for correcting any interference at his own expense

EN55022/CISPR22 Class A ITE (Information Technology Equipment)Class A ITE is a category of all other ITE which satisfies the class A ITE limits but not the class B ITE limits. Such equipment should notbe restricted in its sale but the following warning shall be included in the instructions for use:

Warning : This is a class A product. In a domestic environment this product may cause radio interference in which case the user may berequired to take adequate measures.

Guarantee and CompensationBarco provides a guarantee relating to perfect manufacturing as part of the legally stipulated terms of guarantee. On receipt, the purchasermust immediately inspect all delivered goods for damage incurred during transport, as well as for material and manufacturing faults Barcomust be informed immediately in writing of any complaints.

The period of guarantee begins on the date of transfer of risks, in the case of special systems and software on the date of commissioning,at latest 30 days after the transfer of risks. In the event of justified notice of complaint, Barco can repair the fault or provide a replacementat its own discretion within an appropriate period. If this measure proves to be impossible or unsuccessful, the purchaser can demand areduction in the purchase price or cancellation of the contract. All other claims, in particular those relating to compensation for direct orindirect damage, and also damage attributed to the operation of software as well as to other services provided by Barco, being a componentof the system or independent service, will be deemed invalid provided the damage is not proven to be attributed to the absence of propertiesguaranteed in writing or due to the intent or gross negligence or part of Barco.

If the purchaser or a third party carries out modifications or repairs on goods delivered by Barco, or if the goods are handled incorrectly,in particular if the systems are commissioned operated incorrectly or if, after the transfer of risks, the goods are subject to influences notagreed upon in the contract, all guarantee claims of the purchaser will be rendered invalid. Not included in the guarantee coverage aresystem failures which are attributed to programs or special electronic circuitry provided by the purchaser, e.g. interfaces. Normal wear aswell as normal maintenance are not subject to the guarantee provided by Barco either.

The environmental conditions as well as the servicing and maintenance regulations specified in the this manual must be complied with bythe customer.

TrademarksBrand and product names mentioned in this manual may be trademarks, registered trademarks or copyrights of their respective holders.All brand and product names mentioned in this manual serve as comments or examples and are not to be understood as advertising forthe products or their manufacturers.

Table of contents

TABLE OF CONTENTS

1. Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31.1 Safety guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41.2 Important safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51.3 Important warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61.4 Important warnings for the FLX Power System DPR-2700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71.5 Proper usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2. Installation requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92.1 Mechanical requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102.2 Electrical requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112.3 System requirements for the Control software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

3. Components of an FLX display system .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133.1 System overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143.2 FLX-24 Pixel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163.3 FLX-NNI Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203.4 FLX-NNI Controller user interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223.5 FLX-HUB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303.6 FLX power system DPR-2700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343.7 DX-700 Digitizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 393.8 DX-100 Digitizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403.9 Control software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

4. Installation procedures.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .434.1 Set up process of an FLX display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444.2 Overview cabling FLX system with FLX-24 pixels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454.3 Mounting the FLX-24 pixel in its socket. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464.4 Mounting the rental bracket on the FLX-HUB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474.5 Mounting the fixed bracket on the FLX-HUB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 494.6 Mounting the 19” rack bracket on the FLX-HUB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504.7 Installing the RJ45 IP66 protection shells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

5. Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .535.1 Cleaning the FLX-24 pixel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 545.2 Cleaning the FLX-HUB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 555.3 Replacing the FLX-NNI Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56

A. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57A.1 Dimensions of the FLX-24 pixel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58A.2 Dimensions of the FLX-24 adapter cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59A.3 Dimensions of the FLX-S Strips. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60A.4 Dimensions of the FLX-NNI Controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61A.5 Dimensions of the FLX-HUB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62A.6 Dimensions of the FLX-HUB fixed bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63A.7 Dimensions of the FLX Power Chassis DPR-2700. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64

B. Specifications .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65B.1 FLX-24 specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66B.2 Weight of individual parts of an FLX system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

C. Order info . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69C.1 Order info list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70

Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71

R59770420 FLX-24 21/12/2009 1

Table of contents

2 R59770420 FLX-24 21/12/2009

1. Safety

1. SAFETY

About this chapterRead this chapter attentively. It contains important information to prevent personal injury while installing the FLX-24. Furthermore,it includes several cautions to prevent damage to the FLX-24 parts. Ensure that you understand and follow all safety guidelines,safety instructions and warnings mentioned in this chapter before installing the FLX-24. After this chapter, additional “warnings” and“cautions” are given depending on the installation procedure. Read and follow these “warnings” and “cautions” as well.

Overview

• Safety guidelines• Important safety instructions• Important warnings• Important warnings for the FLX Power System DPR-2700• Proper usage

R59770420 FLX-24 21/12/2009 3

1. Safety

1.1 Safety guidelines

Personal protection

WARNING: Ensure you understand and follow all the safety guidelines, safety instructions, warnings andcautions mentioned in this manual.

Installation personnelThis installation must be performed by authorized and qualified technical personnel only.

Accredited safety officers must ensure the safety of the site, construction, assembly, connection, use, dismantling, transport etc. ofsuch safety critical systems.

CautionInstallation should be performed only after you are thoroughly familiar with all of the proper safety checks and installation instructions.To do otherwise increases the risk of hazards and injury to the user.

Assembly parts are designed for intended use only in conjunction with FLX .

Do not modify and/or replicate any component. Barco uses specific materials and manufacturing processes in order to achieve partstrength. Consult Barco for assistance with custom applications.

Always follow Barco installation instructions. Contact Barco if you should have any question regarding the safety of an application.

The manufacturer assumes no liability for incorrect, inadequate, irresponsible or unsafe assembly of systems.

Product careStructural & mounting components should be kept dry, clean, lubricated (only if recommended), coated properly, and otherwisemaintained in a manner consistent with part design. Barco products must be used in a manner consistent with their design andinspected on a routine basis for security, wear, deformation, corrosion and any other circumstances that may affect the load handlingcapability of the part.

Barco recommends inspections at regular intervals for all installations and increasing in frequency for more critical installations. Ifa part is found to have damage, which may cause a decrease in load capability, the part must be removed for service or replacedimmediately.

Under no circumstances are Barco parts repairable by anyone other than Barco.

4 R59770420 FLX-24 21/12/2009

1. Safety

1.2 Important safety instructions

Instructions:

• Read these instructions.• Keep these instructions.• Heed all warnings.• Follow all instructions.• Clean only with materials or chemicals that are inert, nonabrasive, noncorrosive and non-marking. Consult the manufacturer

for further advice should any doubts exist regarding any cleaning procedure.• Do not block ventilation openings. Install in accordance with the manufacturers instructions.• Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that

produce heat.• Do not defeat the safety purpose of the polarized or grounding type plugs/sockets. If the provided sockets/plugs are damaged

then replacement of the defective parts must be undertaken immediately.• Protect the power/data cords from being walked on or pinched particularly at plugs, convenience receptacles, and the point

where they exit from the apparatus. Replace damaged power/data cords immediately.• Only use attachments/accessories specified by the manufacturer.• Disconnect the power to this apparatus during lightning storms or provide suitable additional lightning protection. Unplug this

apparatus when unused for long period of time.• Refer all servicing to qualified service technicians/personnel. Servicing is required when the apparatus has been damaged in

any way, such as power-supply cord or plug is damaged, the apparatus does not operate normally, or has been dropped.• Use only with systems or peripherals specified by the manufacturer, or sold with the apparatus. Use caution during lifting/moving

or transporting to avoid damage by possible tipping.• All locking mechanisms should function properly. Any malfunction locking mechanism of an FLX product should be replaced

prior to product installation.

R59770420 FLX-24 21/12/2009 5

1. Safety

1.3 Important warnings

Important warnings:

• Maximum and minimum ambient temperature:The maximum ambient temperature for the LED wall is 60 °C, the minimum temperature is -20 °C.

• High leakage current:The combination of multiple FLX Power System DPR-2700 units and FLX-NNI Controller units in an installation results in in-creased levels of leakage current. In order to avoid risk of electric shock due to high leakage current, proper grounding of theinstallation is required.

• Flammable materials:Keep flammable materials away from the installation (such as curtains). A lot of energy is transferred into heat. The installationshould be such that the amount of air flow required for safe operation of the equipment is not compromised. Proper ventilationmust be provided.

• Disconnect deviceA readily accessible disconnect device shall be incorporated in the building installation wiring. See also chapter "Importantwarnings for the FLX Power System DPR-2700", page 7.

• Risk of electric shock / Risk of fire:To protect against risk of fire by overloading of power cables, MAXIMUM 256 FLX-24 pixels may be connected to one outputport of the FLX-HUB and MAXIMUM 8192 FLX-24 pixels may be connected to one power output socket of the FLX Powerchassis DPR-2700. The FLX Power System DPR-2700 must be connected to the local power net according the manufacturerspecifications and installation instructions delivered with the FLX Power System DPR-2700. If you are unable to install the ACrequirements, contact your electrician. Do not defeat the purpose of the grounding.

• No self supporting power/data cablesThe FLX-24 Connector strings are not self supporting.

• This equipment MUST be earthed:In order to protect against risk of electric shock, the installation should be properly grounded. Defeating the purpose of thegrounding type plug will expose you to the risk of electric shock.

• Power system:It is recommended to use a TN-S power distribution system (a power distribution system with a separate neutral and groundingconductor) in order to avoid large ground current loops due to voltage differences in the neutral conductor. The total electricalinstallation should be protected by an appropriately rated disconnect switch, circuit breakers, over voltage protector and GroundFault Current Interrupters. The installation shall be done according to the local electrical installation codes. In Europe specialattention should be given to EN 60364, the standard for electrical installation of buildings. In Germany VDE 0100 should beadhered to. In America, special attention should be given to the National Electrical Code, ANSI/NFPA 70.

• Mains cords:The power cords delivered with this system have special properties for safety. They are not user serviceable. If the power cordsare damaged, replace them only with new ones. Never try to repair a power cord.

• Data cables:The data cables provided with this system have special properties for safety. They are not user serviceable. If the data cablesare damaged, replace them only with new ones. Never try to repair a data cable. Avoid exposure of data cables to accidentalcontact with lightning or power conductors.

• IP66 rating:The FLX-24 pixels, the FLX-HUB units and there connecting wires have an IP66 rating and are therefore totally protectedagainst dust and against high pressure water jets from any direction. Do not use these FLX products in an environment whichrequire a better protection rating then the rating it was designed for. The FLX Power System DPR-2700 and the FLX-NNIController units can only be used indoor in a dust free and dry environment.IP-ratings are defined by the IEC 60529 and this standard also explains in detail how the tests should be performed. Thisincludes the duration (time) which the equipment shall withstand water without damage or malfunction.Ingress Protection (IP) rating is identified by a code that consists of the letters IP followed by two digits and an optional letter.

6 dust tight no ingress of dust; complete protection against contact

6 water jets protected against high pressure water jets from any direction

The FLX-24 pixels, the FLX-HUB units and their connecting wires are designed for outdoor use under a protective roof (orsimilar arrangement) that prevents prolonged exposure to rain.The FLX-24 pixels, the FLX-HUB units and their connecting wires are not designed to be subjected to continuous rain, such asunprotected outdoor use. This requires a higher protection rating.

6 R59770420 FLX-24 21/12/2009

1. Safety

1.4 Important warnings for the FLX Power System DPR-2700

Important warnings for the FLX Power System DPR-2700Products are not liable for any hazards incurred by not following proper safety procedures. Installation, Operation and maintenancepersonnel should always follow these safety rules:1. Caution - Do not install or remove any FLX Power Rectifier DPR-2700 unit with the AC Breaker On. The AC Breakers must be

switched to the off position prior to inserting a rectifier unit into a shelf.2. Before the shelf is operational, the AC input frequency and voltage must be verified, AC break rating and type is adequate, and

other environmental conditions as noted in the specifications are met.3. The shelf has passed stringent system testing prior to shipment. To avoid electrical shock, the FLX Power System DPR-2700

shelf requires a single ground point permanently connected to earth ground.4. An AC Breaker must provide adequate isolation between the shelf input and Commercial AC Main.5. The environment should be dust free and controlled by an air condition system. The area must be free of any flammable vapors

or fluids.6. To avoid electrical hazard, the covers must not be removed on any component including the CSU and Rectifiers.7. Circuit breakers must be replaced with approved replacement circuit breakers meeting the original design specification.8. All AC connections must be made per the latest issue of the National Electrical Code and must also conform to all local codes.9. Air flow: Installation of the power supply in a rack should be such that the amount of air flow required for safe operation of the

power supply is not compromised. The required space is as follows:- Top: 4 inch- Bottom: 4 inch- Front: 12 inch- Rear: 12 inch

10. The power supply should only be installed in a “Restricted Access Location”. The definition of a “restricted access location" isa location for equipment where both of following paragraphs apply:- Access can only be gained by SERVICE PERSONS or by USERS who have been instructed about the reasons for therestriction applied to the location and about the precautions that shall be taken.

- Access is through the use of the tool or lock and key, or other means of security, and is controlled by the authority responsiblefor the location.

11. The equipment is not provided with surge protector. When installing, the external surge protector would be required if AC mainstransient voltage exceeds 2500Vpk.

12. Operating ambient temperature: If installed in a closed or multi rack assembly, the operating ambient temperature of the rackenvironment may be higher than the room ambient. Therefore, consideration should be given to install the power supply not inan environment with an ambient temperature of 33°C or higher.

13. Mechanical loading: Mounting of the power supply in a rack should be such that a hazardous condition is not achieved due touneven mechanical loading.

14. Reliable earthing: the power supply should be reliable earthed. Do not connect the ground conductor to the system neutral.The size of the ground conductor should be minimum 8 AWG.

15. AC input connections: All the AC cables can be connected to shelf main input terminals. The recommended AC wires are:- for a Y connection: 8 AWG L1/L2/L3/N- for a Delta connection: 6 AWG L1/L2/L3

16. The FLX Power System DPR-2700 is only for connection with the Barco FLX-HUB.17. A readily accessible disconnect device shall be incorporated in the building installation wiring. The disconnect device shall be

a circuit breaker or a branch fuse according to the following rating: maximum 60A with 3 poles L1 L2 L3.18. The removable FLX Power Rectifier DPR-2700 units are not HOT SWAPPABLE! The main power must be removed before

unplugging a rectifier.19. A fire enclosure is required in the end installation. Therefore it is mandatory to mount a full metal plate at the top and bottom of

the FLX Power System DPR-2700. The distances specified in point 9 must be respected.

R59770420 FLX-24 21/12/2009 7

1. Safety

1.5 Proper usage

Proper usage of FLX products

• No part of the FLX products can come in contact with any type of abrasive.• No part of the FLX products can come in contact with any type of corrosive substance.• FLX products are to be used in environments meeting the operating specifications.• FLX products are not to be exposed to extreme localized heat or cold exceeding the temperature specifications.• FLX products are not to be exposed to any element or situation that will cause any part of the display to heat beyond what occurs

during normal operation. Such situations include but are not limited to lasers, ultrasonic vibration, or any type of substance thatprevents proper ventilation and heat radiation of the FLX products.

• Power connected to the FLX products must meet the specifications outlined in the installation manual.• Never place an FLX-24 pixel upon a surface with the LED’s side facing downwards. This to prevent damage.• No force can be applied to the LED’s. Any LED’s damaged due to mechanical stress are not covered by the warranty.• Safety and functional features of the FLX-24 pixels cannot be defeated.• Any failures must be immediately and appropriately dealt with (equipment returned to Barco?). Failing equipment cannot be

left to run in an FLX display.• Only Barco cables specified to be used with the FLX products are to be used to connect components in an FLX display. Further,

care must be taken to connect signal only according to the installation manual.• FLX products are not to be used in the vicinity of any equipment that is not CE and UL/ETL certified.• FLX products are not to be transported for any distance in containers other than Barco FLX flight cases or Barco FLX single

unit packaging. Further, even the use of Barco flight cases or packaging material does not guarantee the FLX products againstdamage due to excessive force of impacts.

• FLX products are not to be connected to any non-Barco equipment.• FLX products can be cleaned only in accordance to the procedures defined in the installation manual.

8 R59770420 FLX-24 21/12/2009

2. Installation requirements

2. INSTALLATION REQUIREMENTS

About this chapterThis chapter enumerates the mechanical requirements for the FLX-24 pixel, the electrical requirements to power up the FLX creativeLED display and the system requirements to run the control software efficiently.

Overview

• Mechanical requirements• Electrical requirements• System requirements for the Control software

R59770420 FLX-24 21/12/2009 9

2. Installation requirements

2.1 Mechanical requirements

Mechanical requirements for the FLX-24 pixelBarco offers different carrying systems for the FLX-24 pixel such as the FLX-P50, FLX-P100, FLX-N100, etc. These standard FLXcarrying systems allows a creative, flexible, fast and easy set up of the FLX-24 pixels. The mechanical installation requirementsdepend on the FLX carrying system used. Consult the installation manual, which comes with the FLX carrying systems, to know themechanical requirements of the FLX carrying system.

Next to the standard FLX carrying systems that Barco offers, you can design your own FLX carrying solution. The illustration belowshows the cutting dimensions for the FLX-24 pixel. For more information or help about FLX-24 pixel support grids, contact Barco.

Alignment of the FLX-24 pixelsIt is recommended that all pixels of the same display are equally oriented to avoid color deviations when looking at the display underextreme viewing angels. There are two solutions to align the FLX-24 pixels easily.1. The first solution is using a support plate with a (keyhole) cutout of the top side of the FLX-24 pixel. Note that the top side of

the FLX-24 pixel has a lid which can be used to orient all pixels equally. The drawing below shows the cutout dimensions (inmm) required for the top side of the FLX-24 pixel.

5,3

R0,1

R0,5 (2x)

Ø22,8

Ø19,3

Image 2-1

2. The second solution is using a support plate with one or two raised edges for the FLX-24 pixel socket. Note that the bottomside of the FLX-24 pixel socket has two straight edges (in parallel) which can be used to align the pixel socket. The center ofthe bottom side of the FLX-24 pixel socket is provided with a M3 mounting hole. The maximum depth of this mounting hole is6mm. The drawing below shows the dimensions (in mm) required for the bottom side of the FLX-24 pixel socket.

Ø24

M3

24

1212

24

1212

Image 2-2

The metal plate where the pixel or pixel socket is mounted on, should be 1,5 mm thick. It is recommended to brush the support gridwith grain 120 to smooth away all burns.

CAUTION: Make sure when making your own support grid for the FLX-24 pixel that the support grid is pro-vided with the necessary attachment points to fasten the support grid.

10 R59770420 FLX-24 21/12/2009

2. Installation requirements

2.2 Electrical requirements

Electrical requirements for the FLX-24 pixelThe power for the FLX-24 pixels is delivered by the FLX Power rectifiers DPR-2700 installed in the FLX Power Chassis DPR-2700.One FLX Power chassis DPR-2700, fully equipped with six rectifiers each delivering 2700 watt, consumes maximum 16200 watt.For that one FLX Power System DPR-2700 requires a nominal three phase AC input of 230V (delta connection) or 400V (starconnection), 50-60Hz.

The power cord to connect the FLX Power chassis DPR-2700 with the power net is not delivered with the FLX Power SystemDPR-2700. The customer must provide the correct type of power cord. The cross-sectional area of the conductors in the powersupply cord shall not be less than 6 mm² or 8 AWG for 400V star connection (L1/L2/L3/N/PE) or 10 mm² or 6 AWG for 230V deltaconnection (L1/L2/L3/PE). For more information see the installation manual included in the box of the FLX Power System DPR-2700.

All AC connections must be made per the latest issue of the National Electrical Code and must also conform to all local codes. TheAC supply must be installed by a qualified electrician in conformance to local codes. Hardware, wire sizes and conduit types mustcomply with local codes. To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommendsthat the cabinet be grounded. In no event shall the FLX Power System DPR-2700 be operated without an adequate cabinet groundconnection. An AC breaker must provide adequate isolation between the FLX Power chassis DPR-2700 input and Commercial ACMain.

The power consumption of the FLX-NNI Controller and the DX-100/DX-700 Digitizer is negligible compared to the power consump-tion of the FLX Power System DPR-2700. One FLX-NNI Controller consumes maximum 0,5 amps at 230VAC, 50Hz (100-240VAC;1-0,5A; 50-60Hz). One DX-100/DX-700 Digitizer consumes maximum 0,5 amps at 230VAC, 50Hz. Standard power cords (CEE orNEMA plug) are delivered with the FLX-NNI Controller and the DX-700 Digitizer.

The FLX system allows a physical split up of the control center, where the DX-100/DX-700 Digitizer and FLX-NNI Controller unitsare located, and the power center, where the FLX Power System DPR-2700 is located. This way the length of the power cables canbe shorten to reduce the loss of voltage over the power cables. Futhermore, the heat dissipation and the noise generation of therectifiers can be isolated and managed in a suitable area.

R59770420 FLX-24 21/12/2009 11

2. Installation requirements

2.3 System requirements for the Control software

Before you beginIt is assumed you are familiar with the Windows operating system at your site.

The CD-ROM in your package contains a Windows-based installation program. You can install the software from the CD-ROM.

System requirementsMinimum specifications :

• Hardware- PC Pentium III or equivalent, 2 GHz- 512 Mb RAM- Free hard disk space: 300 Mb- XGA resolution (1024 x 768)- Serial communication port- Ethernet connection

• Software- Windows 20001, Windows XP Home or Windows XP Professional

Recommended specifications :

• Hardware- PC Pentium IV or equivalent, 2.4 GHz- 1 Gb RAM- 300 Mb hard disk free space- SXGA resolution (1280 x 1024) with 32 Mb video memory- Serial communication port- Ethernet connection

• Software- Windows XP Professional or Windows Vista

1. It runs on Windows 2000 but when problems are discovered, Barco does not deliver any support

12 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

3. COMPONENTS OF AN FLX DISPLAY SYSTEM

About this chapterThis chapter gives a global overview of the FLX display system. Furthermore, it describes and locate all the different componentsmore in detail. Note that some FLX components have dedicated manuals to where this chapter will refer to for more detailed infor-mation.

Overview

• System overview• FLX-24 Pixel• FLX-NNI Controller• FLX-NNI Controller user interface• FLX-HUB• FLX power system DPR-2700• DX-700 Digitizer• DX-100 Digitizer• Control software

R59770420 FLX-24 21/12/2009 13

3. Components of an FLX display system

3.1 System overview

Block diagram of an FLX-24 creative display

FLX-HUB FLX-HUB FLX-HUB FLX-HUB

FLX-NNI CTRL FLX-NNI CTRL FLX-NNI CTRL

DX-700Digitizer

Director Toolset(Local PC)

IndoorOutdoor

Control centerPower center

Creative display

Max

256

pix

els

Max 2048 pixels

1

2

4

3

6

PSU

5

Image 3-1Legend:

1 HDMI cable with latches. Maximum cable length of 10 meter between two FLX-NNI Controller units.2 FLX-Data Cable with IP66 protection shells. Maximum cable length of 100 meter between FLX-NNI Controller and FLX-HUB.

14 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

3 FLX-Power Extension Cable. Maximum cable length of 50 meter between PSU (DPR-2700) and FLX-HUB.4 FLX-Power Splitter Cable. 1 to 4.5 FLX-24 converter cable and optional FLX-HUB output extension cable. Maximum 20 meter extension cable between FLX-HUB and connector string with FLX-24.6 FLX-24 Connector string. Strings can be interconnected up to 256 pixels.

For detailed cabling information see chapter "Overview cabling FLX system with FLX-24 pixels", page 45.

R59770420 FLX-24 21/12/2009 15

3. Components of an FLX display system

3.2 FLX-24 PixelIntroductionThe FLX-24 pixel is a compact, high quality LED pixel module that can be combined with a wide variety of specifically designedcarriers (mechanical structures) into any shape you desire. The FLX-24 pixel has a 24 mm diameter and one full-color LED. Thehousing of the FLX-24 pixel has an IP66 rating.

Image 3-2

Parts location of the FLX-24 Pixel

3

1

2

5

4

6Image 3-31 Lens in front of three color LED.2 Orientation notch.3 Left/Right alignment marking.4 Spare opening to remove pixel from socket with flat blade screw driver.5 Positioning pins.6 Socket pins.

Parts location of the FLX-24 connector string

1

4

23

Image 3-41 Male data plug, input side (bayonet mount locking mechanism).2 FLX-24 socket (see details below).3 FLX-24 Pixel.4 Female data plug, output side (bayonet mount locking mechanism).

16 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

1

3

2

5

4Image 3-51 Left/Right alignment marking.2 Socket cable output mark.3 Positioning holes.4 O-ring for IP66 sealing. Rubbed with “Interflon fluor grease 2”.5 Socket fixation hole M3 (maximum depth = 6 mm).

Parts location of the FLX-S connector strip

1

4

23

Image 3-61 Male data plug, input side (bayonet mount locking mechanism).2 Carrier with FLX-24 sockets mounted on PCB.3 FLX-24 Pixel.4 Female data plug, output side (bayonet mount locking mechanism).

CAUTION: Prevent at all times that dust or dirt sticks to the O-ring of the FLX-24 pixel socket. In case theO-ring is damaged or contaminated with dust and/or dirt the IP66 rating can no longer be guaranteed. Notethat Teflon spray is applied to the O-ring to ensure a good sealing without risk of degeneration of the O-ring.

Do not let an FLX-24 pixel socket unused. Always install an FLX-24 pixel upon each socket in the pixel string.Keep the FLX-24 pixel upon the socket for storing.

ConnectivityThe FLX-24 Pixel can be plugged into a molded FLX-24 socket on a cable or into a FLX-24 socket witch is mounted on a strip (PCBboard). Barco offers two standard connector strings and two standard strips:

• FLX-24 connector string for 16 FLX-24 Pixels at a pitch of 16 cm. (R9899549: 1 piece)• FLX-24 connector string for 64 FLX-24 Pixels at a pitch of 16 cm. (R9899550: 1 piece)• FLX-S50 strip for 16 FLX-24 Pixels at a pitch of 50 mm. (R9899556B16: 16 pieces)• FLX-S25 strip for 32 FLX-24 Pixels at a pitch of 25 mm. (R9899555B16: 16 pieces)

R59770420 FLX-24 21/12/2009 17

3. Components of an FLX display system

The connector string and strips can be used together in the same FLX-24 pixel string. The plugs of the connector strings and stripsare from the bayonet mount locking mechanism. Up to 256 FLX-24 pixels can be connected in one string. Each FLX-24 pixel stringmust be connected via an FLX-24 converter cable (R9899553B8: 8 pieces) with one of the output ports of the FLX-HUB.

Image 3-7FLX-24 converter cable (R9899553B8: 8 pieces)

xxx image cable strings 16/64 missing xxx

Image 3-8Standard FLX-S50 strip (R9899556B16: 16 pieces)

Image 3-9Standard FLX-S25 strip (R9899555B16: 16 pieces)

CAUTION: The last unused output plug in the connector string must be sealed with a protection cap to meetthe IP65 rating of the system.

AccessoriesUp to 5 meter of FLX-24 data extension cables can be used between two FLX-24 pixels. Barco offers two lengths of FLX-24 exten-sion cables:

• FLX-24 data extension cable of 2 meter.• FLX-24 data extension cable of 5 meter.

Barco offers also a FLX-24 Dummy plug (bridge connector) to cover unused FLX-24 sockets and to bridge the signals to the nextFLX-24 pixel in the string.

xxx image bridge connector missing xxx

18 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

Image 3-10FLX-24 data extension cable (R9899552: 1 piece of 2 meter; R9899561: 1 piece of 5 meter)

R59770420 FLX-24 21/12/2009 19

3. Components of an FLX display system

3.3 FLX-NNI ControllerIntroduction FLX-NNI ControllerThe housing of the FLX-NNI Controller has a width of 19” (480mm) and a height of 5,25” (133mm) which is the equivalent of 3 rackunits U (1U = 1,75” = 44,45mm). These dimensions makes the FLX-NNI Controller suitable to build in a standard 19” rack. Therear side of the FLX-NNI Controller is equipped with a power input socket (type C14) on which the required input voltage of 100-240VAC; 1-0,5A; 50-60 Hz (0,5 amps at 230VAC) is applied to. The FLX-NNI Controller is not designed for outdoor use and thus mustinstalled indoor.

The front side of the FLX-NNI Controller consist in an ON/OFF switch, an LCD display, a navigation button, one data input socket,two data output sockets, and eight data output ports (type RJ45). With the LCD display and navigation button you can retrieve/mod-ify several settings/values of the FLX-NNI Controller and of the connected FLX-HUB units. The data input socket (IN) has to beconnected with the output port of the DX-700 Digitizer or with one of the two data output sockets (TRU) of the previous FLX-NNIController. Each data output port can be connected to one FLX-HUB. The data output ports are numbered from 1 to 8, left to rightand top to bottom.

The FLX-NNI Controller can only be used with the new generation of DX digitizers like the DX-100 and DX-700 Digitizer. The re-syncunit detects the data stream applied to the data input socket. The controller extracts its required data from the incoming data stream.The extracted content if further processed and sent via the eight data output ports to the FLX-HUB units. Furthermore, the re-syncunit reinforces the incoming data stream and redirects the stream to the data output ports (TRU).

The standard data cable used between the FLX-NNI Controller units are of the straight type (not crossed). Because of this thedata input port is designed as “slave” port and the two data output ports are designed as “master” ports. The differences betweenthe “slave” and “master” ports is that the receiving and transmitting pins are switched. A data connection between two FLX-NNIController units must always be made between a “master” port and a “slave” port. Nevertheless, the data stream is bidirectional. Itis also important to know that the digitizer output is of the “master” type.

CAUTION: Barco uses HDMI connectors and cables, which allows a higher bandwidth for data communicationbetween the FLX-NNI Controller units and DX-700 Digitizer. Nevertheless, Barco does not use the standardHDMI protocol but their own communication protocol NNI (New Netebuk Interface). As a result the pin config-uration of the HDMI connector is different as well. Because of this never connect a device, having standardHDMI input or output ports such as an LCD display or a DVD player, with an FLX-NNI Controller unit or a DX-700Digitizer. Such a connection could be harmful for both Barco devices as for the standard HDMI devices.

Parts location of the FLX-NNI Controller

6

23

45

1Image 3-111 data input port.2 data output port.3 LCD display.4 ON/OFF switch.5 Menu navigation button.6 Eight data output ports (RJ45).

The FLX-NNI Controller unit can only be used with the new generation of DX digitizers like the DX-100 andDX-700 Digitizer.

20 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

Cables used with the FLX-NNI ControllerThe FLX-NNI Controller unit comes with an EU power cord and a US power cord.

Image 3-12 Image 3-13

Barco offers three lengths of NNI cables (HDMI plugs with latches) to connect the FLX-NNI Controller units with each other. Thedifferent lengths are 1 meter, 5 meter and 10 meter. Note that one NNI cable of 1 meter is delivered with the FLX-NNI Controller.

Image 3-14NNI cable of 1 meter with latch (R9854800: 5 pieces).

Image 3-15NNI cable of 5 meter with latch (R9854790: 5 pieces).

Image 3-16NNI cable of 10 meter with latch (R9854860: 5 pieces).

To connect the output ports of the FLX-NNI Controller with the FLX-HUB units Barco offers FLX-data cables with RJ45 plugs whichare equipped with IP66 protection shells. The FLX-data cables are not included because the length of these cables vary fromapplication to application. There are three lengths available: 20 meter, 50 meter and 100 meter.

Futhermore, Barco offers also an IP66 upgrade kit for the RJ45 plugs of a standard network cable. The standard network cablesused must be of the Cat 5 - STP type. Note that the maximum allowed distance between FLX-NNI Controller and FLX-HUB is 100meter. Only the RJ45 plug at the side of the FLX-HUB requires IP66 protection shells.

Image 3-17FLX-Data cable with IP66 protection shells for the RJ45plugs (R9899436: 20 meter; R9899437: 50 meter;R9899438: 100 meter).

Image 3-18IP66 protection shells for the RJ45 plugs of the FLX-Datacable (R9856140B10: 10 pieces).

R59770420 FLX-24 21/12/2009 21

3. Components of an FLX display system

3.4 FLX-NNI Controller user interfaceMenu functionalityThe user interface of the FLX-NNI Controller allows to configure:

• the address of the local FLX-NNI Controller unit.• the LCD contrast of the local FLX-NNI Controller unit.• the digital contrast of the local FLX-NNI Controller unit.• the digital contrast of all FLX-NNI Controller units.• the gamma curve of the local FLX-NNI Controller unit.• the gamma curve of all FLX-NNI Controller units.• the processor test patterns of the local FLX-NNI Controller unit.• the FPGA test patterns of all FLX-NNI Controller units.• the test patterns of all FLX-HUB units connected with the local FLX-NNI Controller unit.• the power ON/OFF of all FLX-HUB units connected with the local FLX-NNI Controller unit.• the default pixel string configuration map of the local FLX-NNI Controller unit.• the restore option (E.g. replacement of an FLX-NNI Controller unit).

Furthermore, the user interface allows to retrieve information such as:

• Address• Board serial number.• Controller serial number.• Software versions.• Number of FLX-HUB units.• Number of pixels.• Pixel type.• Number of lines.• Line length.• Update status.

Navigation buttons

BARCO FLX All controllers►This controllerHUBs

Address 12

5

2 31

64Image 3-191 LCD display of the user interface.2 Enter button.3 Go upwards button.4 Go back button.5 Go downwards button.6 Go forward button (= Enter).

Root menu: BARCO FLXBARCO FLX ► All controllers

This controllerHUBs

Address: 12

This is de root menu of the FLX-NNI Controller. At startup andduring normal operation this menu is displayed. The left sideshows the path of the menu which is “BARCO FLX” for the rootmenu.

The right column shows a list with sub menu items. The itemmarked with a triangle ► is the selected item. Use the navigationbuttons to select another item or to enter one. The last item in thelist is ’Back’ which can be used to go to the previous menu.

The root menu automatically returns after 30 seconds of no actionon the navigation buttons. Except for the menus ’Patterns’, ’Info’and ’Link Errors’ which remain until the ’Back’ action is selected.

22 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

At the left bottom of the menu the address number is displayed ofthe FLX-NNI Controller. Other important messages may appearinstead of the address number such as ! NO SYNC !

BARCO FLX ► All controllersBARCO FLX ► PatternsAll controllers Contrast

Gamma

Back

Address: 12

Via this menu you can select and set the pattern, contrast orgamma for this FLX-NNI Controller unit and all downstreamFLX-NNI Controller units in the system.

TIP: Use the first FLX-NNI Controller unit in the stream to setthe pattern, contrast or gamma.

BARCO FLX ► All controllers ► PatternsBARCO FLX ► Pattern offAll controllers RedPatterns Green

BlueWhiteRamp

Address: 12 ▼

This menu allows you to activate one of the test patterns for thisFLX-NNI Controller unit and all downstream FLX-NNI Controllerunits in the system.

The arrow ▼, in the lower right corner, which is pointingdownwards indicates that the list is longer than the LCD display.Use the navigation buttons to scroll down to see the next items inthe list. An arrow ▲ in the upper right corner will appear.

BARCO FLX Red ▲All controllers GreenPatterns Blue

WhiteRamp

Address: 12 ► Back

The last item in the list is ’Back’ which can be used to go to theprevious menu.

Note that the Patterns menu does not automatically return to theroot menu after 30 seconds of inactivity.

BARCO FLX ► All controllers ► ContrastBARCO FLX ► FullAll controllers Up 10Contrast: 55 Up 1

Down 1Down 10Nill

Address: 12 ▼

This menu allows you to adjust the contrast of this FLX-NNIController unit and all downstream FLX-NNI Controller units in thesystem. The path at the right side shows the current contrastvalue.

The contrast can be adjusted between 0 and 255 in steps of 1 or10. Select ’Full’ to set the contrast immediately to 255 and select’Nill’ to set the contrast to 0.

BARCO FLX Up 10 ▲All controllers Up 1Contrast: 55 Down 1

Down 10Nill

Address: 12 ► Back

The arrow ▼, in the lower right corner, which is pointingdownwards indicates that the list is longer than the LCD display.Use the navigation buttons to scroll down to see the next items inthe list. An arrow ▲ in the upper right corner will appear.

The last item in the list is ’Back’ which can be used to go to theprevious menu.

BARCO FLX ► All controllers ► GammaBARCO FLX ► FlatAll controllers G1Gamma G2

G3G4D1

Address: 12 ▼

This menu allows you to select and activate a gamma curvefor this FLX-NNI Controller unit and all downstream FLX-NNIController units in the system. Use the navigation buttons toselect one of the predefined gamma curves and press the enterbutton (center button) to activate the gamma curve.

BARCO FLX G3 ▲All controllers G4Gamma D1

D2D3

Address: 12 ► Back

The arrow ▼, in the lower right corner, which is pointingdownwards indicates that the list is longer than the LCD display.Use the navigation buttons to scroll down to see the next items inthe list. An arrow ▲ in the upper right corner will appear.

The last item in the list is ’Back’ which can be used to go to theprevious menu.

Gamma

The transfer characteristics of most cameras and displays are nonlinear. For a display, a small change in amplitudewhen the signal level is small produces a change in the display brightness level, but the same change in amplitude at ahigh level will not produce the same magnitude of brightness change. This nonlinearity is known as gamma. Differentgamma curves are available to compensate the nonlinearity.

R59770420 FLX-24 21/12/2009 23

3. Components of an FLX display system

See user guide of the Director toolset to learn more about Gamma curves.

BARCO FLX ► This controllerBARCO FLX ► Local patternsThis controller Contrast

GammaInfoAddressLCD contrast

Address: 12 String config ▼

Via this menu you have access to different controls of thisFLX-NNI Controller unit only.

BARCO FLX Address ▲All controllers LCD contrastGamma String config

Link errorsRestore settings

Address: 12 ► Back

The arrow ▼, in the lower right corner, which is pointingdownwards indicates that the list is longer than the LCD display.Use the navigation buttons to scroll down to see the next items inthe list. An arrow ▲ in the upper right corner will appear.

The last item in the list is ’Back’ which can be used to go to theprevious menu.

BARCO FLX ► This controllers ► Local patternsBARCO FLX ► Pattern offThis controller RedLocal patterns Green

BlueWhiteCycling

Address: 12 ▼

This menu allows you to activate one of the local test patterns forthis FLX-NNI Controller.

The arrow ▼, in the lower right corner, which is pointingdownwards indicates that the list is longer than the LCD display.Use the navigation buttons to scroll down to see the next items inthe list. An arrow ▲ in the upper right corner will appear.

BARCO FLX Blue ▲This controller Whitelocal patterns Cycling

Pixel on/offPixel off/on

Address: 12 ► Back

The last item in the list is ’Back’ which can be used to go to theprevious menu.

Note that the Patterns menu does not automatically return to theroot menu after 30 seconds of inactivity.

BARCO FLX ► This controller ► ContrastBARCO FLX ► FullThis controller Up 10Contrast: 55 Up 1

Down 1Down 10Nill

Address: 12 ▼

This menu allows you to adjust the contrast of this FLX-NNIController unit. The path at the right side shows the currentcontrast value.

The contrast can be adjusted between 0 and 255 in steps of 1 or10. Select ’Full’ to set the contrast immediately to 255 and select’Nill’ to set the contrast to 0.

BARCO FLX Up 10 ▲This controller Up 1Contrast: 55 Down 1

Down 10Nill

Address: 12 ► Back

The arrow ▼, in the lower right corner, which is pointingdownwards indicates that the list is longer than the LCD display.Use the navigation buttons to scroll down to see the next items inthe list. An arrow ▲ in the upper right corner will appear.

The last item in the list is ’Back’ which can be used to go to theprevious menu.

BARCO FLX ► This controller ► GammaBARCO FLX ► FlatThis controller G1Gamma G2

G3G4D1

Address: 12 ▼

This menu allows you to select and activate a gamma curve forthis FLX-NNI Controller. Use the navigation buttons to selectone of the predefined gamma curves and press the enter button(center button) to activate the gamma curve.

24 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

BARCO FLX G3 ▲This controller G4Gamma D1

D2D3

Address: 12 ► Back

The arrow ▼, in the lower right corner, which is pointingdownwards indicates that the list is longer than the LCD display.Use the navigation buttons to scroll down to see the next items inthe list. An arrow ▲ in the upper right corner will appear.

The last item in the list is ’Back’ which can be used to go to theprevious menu.

Gamma

The transfer characteristics of most cameras and displays are nonlinear. For a display, a small change in amplitudewhen the signal level is small produces a change in the display brightness level, but the same change in amplitude at ahigh level will not produce the same magnitude of brightness change. This nonlinearity is known as gamma. Differentgamma curves are available to compensate the nonlinearity.

See user guide of the Director toolset to learn more about Gamma curves.

BARCO FLX ► This controller ► InfoInfo page 1

Barco FLX, This controller, Info (1/3)

Address: 3 Temperature: 36°CCtrl serial : <zzzzzzzzzzzz>Board serial: <xxxxxxxxxxxxxxxxxx>

Input(HxV): 1632x616 ►Continue

This menu displays information about this FLX-NNI Controller.This menu has three pages. The first page shows the address,temperature, serial number of the FLX-NNI Controller, serialnumber of the internal circuit board and the horizontal and verticalresolution of the incoming data stream (IN) from the digitizer.Press the select button to go to the next page (Continue).

Info page 2

Barco FLX, This controller, Info (2/3)

VERSIONS:SoftWare: 1.0.0 Backup SW: 1.0.0FirmWare: 1.0.0 Backup FW: 1.0.0CPLD: 1.3

►Continue

The second page of the info menu shows all the software/firmwareversions of this FLX-NNI Controller.

Info page 3

Barco FLX, This controller, Info (3/3)

OUT 1: OK OUT 5: NCOUT 2: OK OUT 6: NCOUT 3: OK OUT 7: OKOUT 4: OK OUT 8: OK

►Continue

The third page of the info menu shows the status of all eightdata output ports of this FLX-NNI Controller. ’OK’ means thatan FLX-HUB is connected with the output port. ’NC’ means thatno FLX-HUB was found.

BARCO FLX ► This controller ► AddressBARCO FLX ► Up 10This controller Up 1Address: 12 Down 1

Down 10

BackAddress: 12

This menu allows you to set the address of this FLX-NNIController. The address can be set per step or per 10 steps. Thelowest address number is 0, the highest is 32767. Note that theaddress number 0 is reserved for broadcasting. Each FLX-NNIController is listening to the broadcast address 0 and to its ownaddress. So, it’s recommend to start the address numbering from1 or higher.

BARCO FLX ► This controller ► LCD contrastBARCO FLX ► Up 10This controller Up 1LCD contrast: 45 Down 1

Down 10

BackAddress: 12

This menu allows you to set the LCD contrast of this FLX-NNIController. The LCD contrast can be adjusted between 0 and255 in steps of 1 or 10.

R59770420 FLX-24 21/12/2009 25

3. Components of an FLX display system

BARCO FLX ► This controller ► String configBARCO FLX ► Default configThis controller RestoreString config

Back

Address: 12

The FLX-NNI Controller contains a default pixel stringconfiguration. This default configuration consist of 64 lines of 256pixels. The first 8 lines are applied to the data output port 1 (OUT1), the next 8 to port 2 (OUT 2) and so on. The first line on eachport goes to the first output of its connected HUB. The second lineto the second output and so on up to eight.

This default line/pixel configuration allows to view content or testpatterns on the pixels connected with the FLX-NNI Controller.The content displayed will be mixed up because the physicallocation of the pixels does probably not match with the defaultconfiguration.

LOADING! PLEASE WAIT ...

Note that the pixel string configuration, which was set by theDirector toolset, is stored in the flash memory of the FLX-NNIController and thus remains available for restoring.

This message will appear during the ’Restore’ action.

BARCO FLX ► This controller ► String config ► Default configBARCO FLX Load will overrideThis controller the active configString config until power off/onDefault config or Restore

► Load nowAddress: 12 Back

This menu allows you to start loading the default configuration.

Note that the default pixel string configuration will overrulethe active pixel string configuration which was set by theDirector toolset.

Only a restore action or a power off/on action will retrieve theoriginal pixel string configuration set by the Director toolset.

LOADING! PLEASE WAIT ...

Loading in progress ....

Calculation Creative Mask ...

Loading in progress ....

Calculation Creative Map ...

Loading in progress ....

Once the default string configuration is loaded, the ’String config’menu is displayed.

BARCO FLX ► This controller ► Link ErrorsBARCO FLX IN : 0This controller TRU1:0Link Errors TRU2:0

► ResetBack

Address: 12

This menu displays the counted link errors of the data IN anddata TRU connections of the FLX-NNI Controller. This is veryhelpful if you see for example sparkles on the screen, or if thecommunication seems to work hardly. On the LCD-display,you see the number of errors on the input and the two outputconnections. 0 means no errors, 65535 means maximum numberof errors. The error counter increments, if errors are detected,until you press Reset (counting restarts from 0).

REMARK: A not-connected data IN port will always displaymaximum number of errors (65535; just ignore this).

TIP: It may be helpful to count the errors over a very long periodof time in case errors occur exceptional. The menu doesn’tdisappear after a given time. If after a long period the errorcounter is still zero, you can conclude that this path is OK.

26 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

BARCO FLX ► This controller ► Restore settingsBARCO FLX This option allowsThis controller restoring controllerRestore settings settings from a HUB

► ContinueBack

Address: 12

The ’Restore settings’ is a very useful option to get back all thesettings of the FLX-NNI Controller in case of a replacement. Theresult is an image on the screen which is exactly the same asbefore. In other words, no ’Init replaced’ or ’Re-detection’ with theDirector toolset has to be done.

The option ’Restore settings’ is possible because the FLX-NNI Controller sends every 5 minutes all settingsof the FLX-NNI Controller to the flash memory of all connected FLX-HUB units. This way, a backup is made ofthe FLX-NNI Controller settings (Address, Board serial, Ctrl serial, Gamma, Contrast, etc. Excluding the pixelstring configuration map).

A backup is made of the ’pixel string configuration map’ during the upload of the design in the FLX-NNI Con-troller with the Director toolset. This backup is stored in the flash memory of the first detected FLX-HUB. So,only one of the connected FLX-HUB units contains the backup of the pixel string configuration map. Thismeans that you have to select this FLX-HUB which contains the backup of the map to restore all the informa-tion (map + settings). Otherwise, only the FLX-NNI Controller settings will be restored.

The ’Restore settings’ option has to be activated within 5 minutes after the power is switched on of the newFLX-NNI Controller. Otherwise, the new FLX-NNI Controller will overwrite the stored settings on all connectedFLX-HUB units with its settings. This will make the pixel string configuration map unavailable for restoring.

BARCO FLX Next HUBThis controller Previous HUBRestore settings ► Restore nowFrom HUB OUT 1

Back

Address: 12

This menu (at the left) allows you to select the HUB from which youwant to restore the settings. By default the FLX-HUB is selectedwhich contains the backup of the pixel string configuration mapas well. It’s recommended not to select another FLX-HUB unlessthere is a sound reason to do so (E.g. service purposes).

The best procedure to replace an FLX-NNI Controller is:1. Switch off the FLX-NNI Controller.2. Disconnect all cables.3. Replace the FLX-NNI Controller.4. Reconnect all cables.5. Switch on the FLX-NNI Controller.6. Activate the ’Restore settings’ option via the menu of the

FLX-NNI Controller within 5 minutes after power on. Use thedefault FLX-HUB to restore the settings from.

Restoring the settings from HUB OUT 1 ...

This message appears during the restoring process.

Not possible because backuped datais the same as control-box data

This message appears in case you try to restore the FLX-NNIController settings after the power is switched on for more then5 minutes.

not possible because HUBis not found

This message appears in case the HUB is not found. After a fewseconds the previous menu will appear.

R59770420 FLX-24 21/12/2009 27

3. Components of an FLX display system

BARCO FLX ► HUBsBARCO FLX ► Next HUBHUB OUT 1 Previous HUB

PatternsInfoPower off HUBs

Address: 12 Back

Via this menu you can select one of the connected FLX-HUB unitsto set a local pattern or retrieve information. Furthermore, anoption is provided to switch the power of all connected FLX-HUBunits on or off.

BARCO FLX ► HUBs ► PatternsBARCO FLX ► Pattern offHUBs RedPatterns Green

BlueWhiteString colors

Address: 12 Running pattern ▼

This menu allows you to activate one of the local test patterns forthe connected FLX-HUB units.

The arrow ▼, in the lower right corner, which is pointingdownwards indicates that the list is longer than the LCD display.Use the navigation buttons to scroll down to see the next items inthe list. An arrow ▲ in the upper right corner will appear.

BARCO FLX ► HUBs ► PatternsBARCO FLX White ▲HUBs String colorsPatterns Running pattern

Running pixelFlying pixel

Address: 12 ► Back

The last item in the list is ’Back’ which can be used to go to theprevious menu.

Note that the Patterns menu does not automatically return to theroot menu after 30 seconds of inactivity.

BARCO FLX ► HUBs ► InfoHUB OUT 1 InfoS/N: 123456789Versions:Software: 01.00.0 Backup: 01.00.0Firmware: 01.00.0 Backup: 01.00.0Pixel type: FLX-24Pixels: 256,128,128,64,64,64,64,4

This menu displays information about the selected FLX-HUBsuch as serial number, software/firmware versions, connectedpixel type and the number of pixels connected per FLX-HUBoutput port.

BARCO FLX ► HUBs ► Power offBARCO FLX POWER OFFHUBs ALL HUBSPower off

► YesBack

Address: 12

This option allows you to switch off the power of all FLX-HUBunits connected with this FLX-NNI Controller.

BARCO FLX ► HUBs ► Power onBARCO FLX POWER ONHUBs ALL HUBSPower on

► Yes

Back

Address: 12

This option allows you to switch on the power of all FLX-HUBunits connected with this FLX-NNI Controller.

Other important popup messages

! BACKUP FIRMWARE !

This message appears in case the FLX-NNI Controller unit runswith backup firmware. This means that the main firmware iscorrupt and should be updated. Updating the firmware of theFLX-NNI Controller unit has to be done with the Director toolset.See user guide of the Director toolset for detailed instructions.

Note that the functionality of an FLX-NNI Controller unit whichruns with backup firmware is almost completely disabled. Onlythe firmware can be updated.

28 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

RUNNING BACKUP SOFTWARELOAD RUN SOFTWARE

This message appears in case the FLX-NNI Controller unit runswith backup software. This means that the main software iscorrupt and should be updated. Updating the software of theFLX-NNI Controller unit has to be done with the Director toolset.See user guide of the Director toolset for detailed instructions.

Note that the functionality of an FLX-NNI Controller unit whichruns with backup software is limited. The content of the first pixelis copied on all other pixels.

SYNC LOST !Please check cables

This message appears in case the FLX-NNI Controller unit doesnot find a sync signal on the data input socket (IN). Check all datacables in the upstream of the system.

After a few seconds this message will be replaced by the rootmenu. In the lower left corner of the root menu the message ’!NO SYNC !’ will remain.

HUB update init

This message appears when initializing the software updateprocess for all FLX-HUB units connected with the FLX-NNIController unit.

HUB update retry

This message appears when the first attempt to update thesoftware for all FLX-HUB units connected with the FLX-NNIController unit failed.

HUB update ...%

This message appears during the software update process of allFLX-HUB units connected with the FLX-NNI Controller unit.

HUB update transfer

This message appears during the transfer in the update processof all FLX-HUB units connected with the FLX-NNI Controller unit.

HUB update checksum

This message appears during the checksum in the update processof all FLX-HUB units connected with the FLX-NNI Controller unit.

HUB update error

This message appears in case an error occurred during theupdate process of all FLX-HUB units connected with the FLX-NNIController unit.

HUB update done

This message appears in case the update process of all FLX-HUBunits connected with the FLX-NNI Controller unit was successful.

R59770420 FLX-24 21/12/2009 29

3. Components of an FLX display system

3.5 FLX-HUBIntroductionThe FLX-HUB is the interface between the FLX-24 pixel strings, the FLX-NNI Controller and the DPR-2700 power system. Powerfrom the DPR-2700 power system and data from the FLX-NNI Controller are brought together on the FLX-HUB for further distributionto the FLX-24 pixel strings.

The robust housing of the FLX-HUB has an IP66 protection rating which makes the FLX-HUB suitable for outdoor installations. TheFLX-HUB has one data input port (RJ45 socket), eight power/data output ports (one port per pixel string) and one multi pole powerinput socket. Eight power circuits, one power circuit per output port, enter the FLX-HUB via this multi pole power input socket. Thepower/data output ports are numbered and equipped with a protection cap. The data input port and the power/data output portshave a diagnostic LED for fast troubleshooting.

The FLX-HUB has an internal test pattern generator which can be activated via the user interface of the FLX-NNI Controller or viathe Director toolset. The Director toolset can be used to updated the software and firmware of the FLX-HUB as well.

Interesting to know is that all the FLX-HUB units contains a backup of the settings (address, gamma curve, board serial number, etc.)of the connected FLX-NNI Controller unit. Only the first detected FLX-HUB (first used output of the FLX-NNI Controller) contains thepixel string configuration map of the connected FLX-NNI Controller unit. Take this into account when replacing one of the FLX-HUBunits. Use the Director toolset to send a new ’backup’ of the pixels string configuration map to the replaced components.

CAUTION: A pixel string of maximum 256 FLX-24 pixels may be connected to one power/data output port ofthe FLX-HUB.

Part location of the FLX-HUB

2 31

4

Image 3-201 Multi pole power input socket.2 Power/data output ports (to pixel string).3 Data input port RJ45 (from FLX-NNI Controller).

CAUTION: Make sure that an O-ring is present inside the socket of all Power/data output ports. Replacedamaged O-rings immediately.

Mounting accessories of the FLX-HUBDue to the versatility and creativity of FLX applications the FLX-HUB has to be mount in different environments (indoor, outdoor,hanging, etc.). For that Barco offers three different mounting brackets for the FLX-HUB:

• 19” rack mounting bracket for dual FLX-HUB.• Rental mounting bracket.• Fixed mounting bracket (fix install).

The 19” rack mounting bracket for dual FLX-HUB is included in the order package of two FLX-HUB units:R9856090B2.

30 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

Image 3-2119” rack mounting bracket for dual FLX-HUB.

Image 3-22Rental mounting bracket (R9863020: 2 pieces).

Image 3-23Fixed mounting bracket (R9863030: 4 pieces).

Cables used with the FLX-HUBSee the chapters about FLX-NNI Controller, DPR-2700 power system and FLX-24 pixel for information of cables used with theFLX-HUB.

FLX-HUB input port diagnostic LEDInput LED Situation Action

Off 1. The input port (RJ45 socket) of theFLX-HUB is not connected with theFLX-NNI Controller.

2. The power of the FLX-HUB isswitched off. Note that in this caseall FLX-HUB units connected withthe FLX-NNI Controller are switchedoff.

1. Check the cabling of the FLX-HUB.2. Switch on the power of the FLX-HUB

via the user interface of the FLX-NNIController or use the Director toolset.

Red flashing Normal operation. (no action required)

Flashing once + pause The FLX-HUB runs with backup firmware.The normal firmware is corrupt. Thissituation may occur after an unsuccessful(interrupted) firmware update with theDirector toolset. Note that the FLX-HUBremains full operational.

Update the firmware of the FLX-HUBusing the Director toolset. Note that (atleast) all FLX-HUB units connected withFLX-NNI Controller will be updated.

Flashing twice + pause The FLX-HUB runs with backup software.The normal software is corrupt. Thissituation may occur after an unsuccessful(interrupted) software update with theDirector toolset. Note that the FLX-HUBremains full operational.

Update the software of the FLX-HUBusing the Director toolset. Note that (atleast) all FLX-HUB units connected withFLX-NNI Controller will be updated.

Flashing fast The FLX-HUB runs in ’boot loader’. Thisis really an exceptional situation.

Replace the FLX-HUB unit and send themalfunction unit back to factory for repair.

FLX-HUB output port diagnostic LED(s)Output LED Situation Action

Off 1. The input port (RJ45 socket) of theFLX-HUB is not connected with theFLX-NNI Controller.

2. The power of the FLX-HUB isswitched off. Note that in this caseall FLX-HUB units connected withthe FLX-NNI Controller are switchedoff. The diagnostic LED of the inputport remains off as well.

3. No power voltage available on theFLX-HUB. The diagnostic LED ofall output ports remain off and thediagnostic LED of the input port isflashing.

1. Check the data cabling (RJ45socket) between the FLX-HUB andthe FLX-NNI Controller.

2. Switch on the power of the FLX-HUBvia the user interface of the FLX-NNIController or via the Director toolset.

3. Check the power cabling betweenthe FLX-HUB and the DPR-2700power system (PSU). Make sure thatthe PSU is switched on an functionnormally.

4. Check if the load breaker of thiscircuit in the PSU DPR-2700 isswitched on. See manual of the

R59770420 FLX-24 21/12/2009 31

3. Components of an FLX display system

Output LED Situation Action

4. No power voltage available for thisoutput port of the FLX-HUB. Thediagnostic LEDs of the other outputports are lighting red or yellow.

DPR-2700 power system.

Red There is no connection with an FLX-24pixel string detected on this output port ofthe FLX-HUB.

Connect an FLX-24 pixel string with thisoutput port of the FLX-HUB.

Yellow There is an connection with an FLX-24pixel string detected on this output port ofthe FLX-HUB.

(no action required)

HUB internal power wiringFRONT VIEW

Connector Pin

BACK VIEW Signal

3 8 -54VJ1

GND 9 0V

3 6 -54VJ2

GND 7 0V

3 16 -54VJ3

GND 15 0V

3 4 -54VJ4

GND 5 0V

3 10 -54VJ5

GND 11 0V

3 18 -54VJ6

GND 13 0V

3 12 -54VJ7

GND 1 0V

3 2 -54VJ8

32 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

FRONT VIEW

Connector Pin

BACK VIEW Signal

GND 3 0V

1 2

3

1 2

3

1 2

3

1 2

3

1 2

3

1 2

3

1 2

3

1 2

3

FRONT VIEW

BACK VIEW

Image 3-24

R59770420 FLX-24 21/12/2009 33

3. Components of an FLX display system

3.6 FLX power system DPR-2700

IntroductionThe FLX Power System DPR-2700 consists of a chassis with two DC distribution shelves of three modular FLX Power RectifierDPR-2700 units and a Control and Supervisory Unit (CSU). The FLX Power System DPR-2700 requires a nominal three phase ACinput of 230V (delta connection) or 400V (star connection), 50-60Hz.

The rear side of the power chassis has two power output ports (multi pole sockets) which provide in 16 (2 x 8) protected circuits witha DC output of -54V.

One power output port of the FLX Power System DPR-2700 can power maximum 8192 FLX-24 pixels. The FLX Power SystemDPR-2700 has two power output ports, so one FLX Power System DPR-2700 can power maximum 16384 FLX-24 pixels. This largenumber of pixels can only be powered in case the total length of the power cables, from the power output port to the last FLX-24 pixelin the connector string, is limited. Otherwise, the voltage drop over the power cables will be too high and because of this disablingthe last FLX-24 pixels in the string.

Image 3-25FLX Power Chassis DPR-2700 without rectifiers (R9899431)

Refer to the manual of the FLX Power System DPR-2700 for more information about installation and usageguidelines.

Parts location

2

3

4

1

Image 3-261 Control and Supervisory Unit (NCSU).2 Removable FLX Power rectifier DPR-2700.3 Female multi pole power output sockets.4 Cable gland for the mains input power cable.

FLX Power Rectifier DPR-2700The FLX Power System DPR-2700 contains 6 removable (not hot swappable) FLX Power Rectifier DPR-2700 units. One rectifiercan deliver 2700 Watt (50 ampere DC). In case a rectifier fails, the other rectifiers remain delivering there maximum power. Forvideo applications with typical video content the FLX Power System DPR-2700 will run at average 30-40% of its maximum. So, incase a rectifier fails it will probably not be visible during the event. The malfunction rectifier can be replaced after the event.

34 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

Image 3-27FLX Power Rectifier DPR-2700 (R9899432)

For critical lighting installations (100% brightness) where no interruption of the event can be afford, it is rec-ommended to reduce the maximum number of FLX-24 pixels per FLX Power System DPR-2700 (80%). So, incase a rectifier fails, the remaining power is sufficient to power the connected FLX system for 100%. Other-wise, it could be that the last pixels in the strings are underpowered which will be noticeable in the displayedcontent.

For monitoring and diagnostics of the FLX Power System DPR-2700 consult the operation manual of the FLXPower System DPR-2700.

Power cables and power splitter cablesBarco offers two lengths of FLX power cables, 5 and 25 meter. Only these power cables and the custom made power cables, whichmeets the requirements as described below, may be used to connect the FLX-HUB with the FLX Power System DPR-2700 (or otherBarco approved power system for FLX).

Barco offers also an FLX power splitter cable which has four output plugs. The normally eight protected circuits per output plug aresplit-up into two protected circuits per output plug. This means that more FLX-HUB units can be connected to the same FLX PowerSystem DPR-2700. However, take into account that maximum 8192 FLX-24 pixels per power output port of the FLX Power SystemDPR-2700 are allowed. With other words, maximum 256 pixels per protected circuit.

Image 3-28FLX Power Cable (R9899434: 5 meter; R9899435: 25meter)

Image 3-29FLX Power Splitter Cable (R9899433)

Custom made FLX power cableSome FLX applications (especially fixed installs) requires a custom made FLX Power Cable. Therefor, Barco offers the male andfemale multi pole power plugs in separated kits. So, the customer can make his own FLX Power Cable with the length he needs(maximum 50 meter).

R59770420 FLX-24 21/12/2009 35

3. Components of an FLX display system

Image 3-30FLX male power plug (R9856150)

Image 3-31FLX female power plug (R9856160)

FLX power cable specificationsVoltage 54V, secundary, isolated from mains.

Current 16A at ambient of 45°C, free in the air or lying on a surface.

# wires 16 wires black, numbers 1-16 printed in white.

1 wire yellow/greenCross-sectional of 1 wire 3 mm² (12AWG)

Operating temp -30°C / +60 °C

Storage temp -40°C / +85°C

Storage humidity 0 – 95 %

UV resistant Yes

All weather resistant Yes

Color Black

Flammability rating VW-1

Hazardous materials RoHS compliant

Approvals UL / CSA

Outer markings 1. Name2. UL approved with file number or logo3. Maximum temperature4. voltage rating5. VW-1

36 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

FLX power cable pin configuration

1 2

Image 3-321 FLX male power plug.2 FLX female power plug.

FLX male powerplug

Pin number

Wire color/section FLX female powerplug

Pin number

Signal

1 ← black 12AWG → 1 0V rail

2 ← white 12AWG → 2 -54V FUSE No.8

3 ← black 12AWG → 3 0V rail4 ← white 12AWG → 4 -54V FUSE No.4

5 ← black 12AWG → 5 0V rail

6 ← white 12AWG → 6 -54V FUSE No.2

7 ← black 12AWG → 7 0V rail

8 ← white 12AWG → 8 -54V FUSE No.1

9 ← black 12AWG → 9 0V rail

10 ← white 12AWG → 10 -54V FUSE No.5

11 ← black 12AWG → 11 0V rail

12 ← white 12AWG → 12 -54V FUSE No.7

13 ← black 12AWG → 13 0V rail

14 N.C. 14 (spare)

15 ← black 12AWG → 15 0V rail

16 ← white 12AWG → 16 -54V FUSE No.317 N.C. 17 (spare)

18 ← white 12AWG → 18 -54V FUSE No.6

19 ← yellow/green 12AWG → 19 EARTH (GND)

WARNING: Only FLX power cables can be used which are made by trained and qualified technicians.

WARNING: To protect the FLX power cables for overheating maximum 4 FLX power cables may be bundledtogether. Futhermore, the FLX power cables must always be used unwound.

R59770420 FLX-24 21/12/2009 37

3. Components of an FLX display system

FLX spider cable pin configuration

J0

J0 J1, J2, J3, J4

J1

J2

J3

J4

Image 3-33

Male power input plug J0 Female power output plug

Pin No. Signal Plug No. Pin No.

1 0V rail J4 5, 7, 9, 15

2 -54V FUSE No.8 J4 2, 10, 12, 18

3 0V rail J4 1, 3, 11, 13

4 -54V FUSE No.4 J2 2, 10, 12, 18

5 0V rail J2 1, 3, 11, 13

6 -54V FUSE No.2 J1 2, 10, 12, 18

7 0V rail J1 1, 3, 11, 13

8 -54V FUSE No.1 J1 4, 6, 8, 16

9 0V rail J1 5, 7, 9, 15

10 -54V FUSE No.5 J3 4, 6, 8, 16

11 0V rail J3 5, 7, 9, 15

12 -54V FUSE No.7 J4 4, 6, 8, 16

13 0V rail J3 1, 3, 11, 13

14 (spare) J1, J2, J3, J4 14

15 0V rail J2 5, 7, 9, 15

16 -54V FUSE No.3 J2 4, 6, 8, 16

17 (spare) J1, J2, J3, J4 17

18 -54V FUSE No.6 J3 2, 10, 12, 18

19 EARTH (GND) J1, J2, J3, J4 19

38 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

3.7 DX-700 Digitizer

GeneralThe DX-700 is a multi-window video processor designed for use as a versatile front-end to all Barco LED products. The digitizerprocesses (image processing, conversion and conditioning) all source signals for digital distribution to every tile.

• Existing (legacy) LED products such as MiPIX, DLite, ILite and OLite are supported via the 32-bit DVI link on the system’s DVIOutput Module.

• Next generation LED products such as the NX-4 tiles are supported via the NNI interface on the system’s NNI Output Module.

Image processing and LED wall configuration and control functions are adjusted from Barco’s Director toolset, or via controls on theDX-700 Digitizer front panel itself. The Director toolset software is designed as a user interface to be used in conjunction with thedigitizer and display. It can be used on a PC that’s connected to the digitizer through a serial RS232 connection.

Image 3-34

CAUTION: Refer to the manual(s) of the used digitizer for more information about installation and usageguidelines.

R59770420 FLX-24 21/12/2009 39

3. Components of an FLX display system

3.8 DX-100 Digitizer

GeneralThe DX-100 is a multi-window video processor designed for use as a versatile front-end to the FLX displays of Barco only. Thedigitizer processes (image processing, conversion and conditioning) all source signals for digital distribution to every FLX-NNI Con-troller,supported via the NNI interface on the system’s NNI Output Module

Image processing and LED wall configuration and control functions are adjusted from Barco’s Director toolset. The Director toolsetsoftware is designed as a user interface to be used in conjunction with the digitizer and display. It can be used on a PC that’sconnected to the digitizer through a serial RS232 connection.

CAUTION: Refer to the manual(s) of the used digitizer for more information about installation and usageguidelines.

40 R59770420 FLX-24 21/12/2009

3. Components of an FLX display system

3.9 Control softwareGeneralThe control software is designed as a graphic user interface (GUI) and can be used to control and configure the digitizer as well asthe Barco LED wall via a PC (e.g. Director toolset).

Minimum required software version: 1.06

Image 3-35Control software “Director toolset”.

CAUTION: Refer to the manual(s) of the used control software for more information about installation andusage guidelines.

R59770420 FLX-24 21/12/2009 41

3. Components of an FLX display system

42 R59770420 FLX-24 21/12/2009

4. Installation procedures

4. INSTALLATION PROCEDURES

About this chapterThis chapter contains general installation procedures for the FLX display.

Overview

• Set up process of an FLX display• Overview cabling FLX system with FLX-24 pixels• Mounting the FLX-24 pixel in its socket• Mounting the rental bracket on the FLX-HUB• Mounting the fixed bracket on the FLX-HUB• Mounting the 19” rack bracket on the FLX-HUB• Installing the RJ45 IP66 protection shells

R59770420 FLX-24 21/12/2009 43

4. Installation procedures

4.1 Set up process of an FLX display

Set up process:1. The first stage in the process is creating in the project in the Director toolset on the basis of a sketch of the creative concept which

you want to realize. A project exist in one or more configurations and each configuration exist in one or more designs of FLX-NNIController units. The designs can be the same or different from each other. Consult the user guide of the Director toolset formore detailed information on how to define a new project.

2. Install the FLX-24 pixels according your creative concept and realize the cabling of the FLX-24 pixels. Note that Barco offersseveral FLX carriers. See installation manual of the used carrier for detailed installation instructions of the FLX-24 pixels. Donot forget to place a protection cap on the last unused plug in the pixel string.In case the standard FLX-24 connector strings does not match with the concept of your creative design, contact Barco for moreinfo about customized FLX-24 connector strings with the pitch that meet your requirements.

3. Install the FLX-HUB units and connect these with the FLX-24 pixel strings. Each output port of the FLX-HUB must be connectedwith an FLX-24 converter cable. The FLX-24 connector string is connected with the output plug of the converter cable. TheFLX-HUB units can be installed in a 19” rack or on stage. See chapters "Mounting the 19” rack bracket on the FLX-HUB", page50 and "Mounting the rental bracket on the FLX-HUB", page 47. Up to 20 meter FLX-HUB output extension cables can be usedto connect the pixel strings with the input ports of the FLX-HUB units. See chapter "FLX-HUB", page 30.

4. Install the FLX-NNI Controller units and connect the data output ports with the data input ports of the FLX-HUB units. Note thatthe maximum allowed length of data cable is 100 meter.When using standard UTP cat 6 network cables, make sure that the RJ45 plugs of the network cables are provided with IP66protection shells. See chapter "Installing the RJ45 IP66 protection shells", page 51.

5. Connect the data IN and TRU ports of the FLX-NNI Controller units with each other. The maximum allowed length is 10 meter.6. Provide each FLX-NNI Controller unit with power.7. Install the DX-700 Digitizer, apply a source and connect the data output port of the digitizer with the input port of the first FLX-NNI

Controller unit in the system. See installation manual of the DX-700 Digitizer for detailed installation instructions.8. Install the FLX Power System DPR-2700 units and connect the power output sockets with the FLX-HUB units. Maximum 50

meter power cable is allowed. Take into account that one FLX Power System DPR-2700 unit can power maximum 16384FLX-24 pixels. Use a power splitter cable to split the power output in to four outputs. See chapter "FLX power system DPR-2700", page 34.Connect all FLX Power System DPR-2700 units with the power net. Make sure that the power net meets the requirements asstated in the chapter "Electrical requirements", page 11.

9. The FLX system is ready now. Switch on all FLX Power System DPR-2700 units, all FLX-NNI Controller units and the DX-700Digitizer. See user guide of the Director toolset for further actions.

44 R59770420 FLX-24 21/12/2009

4. Installation procedures

4.2 Overview cabling FLX system with FLX-24 pixels

Cabling diagram

1

6

4

3

7

11

8

10

9

2

5

Image 4-11 NNI Data cable with latch (HDMI). Connection with the output port of the DX-700 Digitizer. Up to 10 meter or with NNI Fiberlink up to 150 meter.2 NNI Data cable with latch (HDMI). Connection with the next FLX-NNI Controller. Up to 10 meter.3 FLX Data cable with IP66 protection shells (RJ45). Connection with FLX-HUB input port. Up to 100 meter. Standard FTP network cable Cat 5 can be used if equipped

with IP66 protection shells.4 FLX Power Cable. Up to 50 meter.5 FLX Power Splitter Cable. From 1 to 4.6 FLX-HUB output extension cable. Up to 20 meter till FLX-24 converter cable.7 FLX-24 converter cable. Required between each FLX-HUB output port and first FLX-24 connector string.8 FLX-24 connector string. Up to 256 FLX-24 pixels per FLX-HUB output port.9 FLX-S carrier. Up to 256 FLX-24 pixels per FLX-HUB output port.10 FLX-24 extension cable. Up to 5 meter to the next string.11 FLX-24 extension cable. Up to 5 meter between two strings.

An NNI Fiberlink can be used between the digitizer and FLX-NNI Controller units.

CAUTION: The last unused output plug in the connector string must be sealed with a protection cap to meetthe IP65 rating of the system.

R59770420 FLX-24 21/12/2009 45

4. Installation procedures

4.3 Mounting the FLX-24 pixel in its socket

Necessary toolsNo tools.

How to mount the FLX-24 pixel in its socket?1. Check if the socket is provided with an O-ring (red rubber ring).Note: “Interflon fluor grease 2” is applied to the O-ring at factory for an optimal sealing without risk for “stress cracking”. Only

these types of grease are allowed which do not result in “stress cracking”.

2. Approach the socket with the FLX-24 pixel. Make sure that the three positioning pins (reference 3) of the FLX-24 pixel are alignedwith mounting holes (reference 1) on the socket.Tip: One side of the pixel and the socket is marked with “stripes” (reference 2) and the other side with “dots” (reference 4).

These markings can be used for a quick alignment of the pixel on in the socket.

3

4

2

1

Image 4-2

3. Press the FLX-24 pixel in its socket.

To remove the pixel, just pull it straight out of its socket. Or, place the blade of a screw driver in the spareopening at the bottom of the FLX-24 pixel and wriggle it out of its socket.

CAUTION: Prevent at all times that dust or dirt sticks to the O-ring of the FLX-24 pixel socket. In case theO-ring is damaged or contaminated with dust and/or dirt the IP66 rating can no longer be guaranteed. Notethat Teflon spray is applied to the O-ring to ensure a good sealing without risk of degeneration of the O-ring.

Do not let an FLX-24 pixel socket unused. Always install an FLX-24 pixel upon each socket in the pixel string.Keep the FLX-24 pixel upon the socket for storing.

46 R59770420 FLX-24 21/12/2009

4. Installation procedures

4.4 Mounting the rental bracket on the FLX-HUB

Necessary toolsPH1 Phillips screwdriver.

Necessary parts• Four M3x10 cross recessed pan head screws, stainless steel (DIN7985).• Four single coil spring washers, D3.1 - D6.2 (DIN127B).

How to install the rental bracket on the FLX-HUB?1. Place the rental bracket into position as illustrated and fasten with four screws. Use a PH1 Phillips screwdriver the fasten thescrews (reference 1). Make sure that each screw is provided with a spring washer (reference 2).

12

Image 4-3

2. Do you want to use a rigging clamp to install the FLX-HUB?If yes, proceed with step 3.

3. Install the rigging clamp on the rental bracket as illustrated. Note the rigging clamp must has M10 thread.

3

3

Image 4-4

R59770420 FLX-24 21/12/2009 47

4. Installation procedures

4. Secure the rigging clamp by fastening the bolt (reference 3 image 4-4).

48 R59770420 FLX-24 21/12/2009

4. Installation procedures

4.5 Mounting the fixed bracket on the FLX-HUB

Necessary toolsPH1 Phillips screwdriver.

Necessary parts• Four M3x10 cross recessed pan head screws, stainless steel (DIN7985).• Four single coil spring washers, D3.1 - D6.2 (DIN127B).

How to install the fixed bracket on the FLX-HUB?1. Place the fixed bracket into position as illustrated and fasten with four screws. Use a PH1 Phillips screwdriver the fasten thescrews (reference 1). Make sure that each screw is provided with a spring washer (reference 2).

21

Image 4-5

R59770420 FLX-24 21/12/2009 49

4. Installation procedures

4.6 Mounting the 19” rack bracket on the FLX-HUB

Necessary toolsPH1 Phillips screwdriver.

Necessary parts• Four M3x10 cross recessed pan head screws, steel zinc plated (DIN7985).• Four single coil spring washers, D3.1 - D6.2 (DIN127B).

How to mount the 19” rack bracket on the FLX-HUB?1. Place the 19” rack bracket upon the two FLX-HUB units as illustrated. Fasten each FLX-HUB with four screws (reference 1)using a PH1 Phillips screwdriver. Make sure that each screw is provided with a lock washer (reference 2).

12

Image 4-6

2. Now the FLX-HUB assembly can be installed in a standard 19” rack.

50 R59770420 FLX-24 21/12/2009

4. Installation procedures

4.7 Installing the RJ45 IP66 protection shells

The IP66 protection shells can be installed upon the RJ45 plug of standard UTP network cables. The networkcables used between FLX-NNI Controller and FLX-HUB must be of the type UTP cat 6. The maximum lengthmay not exceed 100 meter.

CAUTION: The network cable which has to be plugged into the RJ45 socket of the FLX-HUBmust be equippedwith IP66 protection shells.

How to install the IP66 protection shells on a standard UTP network cable?1. Align the 7 parts as illustrated.

1 2 3 4 5 6 7

Image 4-7

2. Slide part 1 and 3 over the RJ45 connector.

3. Place the sealing rubber (part 2) over the cable, between part 1 and part 3, and slide it into part 3.

4. Place the O-ring (part 4) over the RJ45 connector into part 3.

5. Place the long sealing rubber (part 5) over the cable between part 3 and the RJ45 plug.

1 2 3 4 5 6 7

Image 4-8

6. Slide the long sealing rubber (part 5) against the RJ45 plug and then slide part 3 against the long sealing rubber.

Image 4-9

7. Place part 6 over the RJ45 plug and fasten with part 7.

Image 4-10

8. Fasten the back end of the shell with part 1.

R59770420 FLX-24 21/12/2009 51

4. Installation procedures

Image 4-11

52 R59770420 FLX-24 21/12/2009

5. Maintenance

5. MAINTENANCE

About this chapterThis chapter contains some maintenance information about the FLX-24 pixel and the FLX-HUB which can be performed by thepersons who do the installation.

Overview

• Cleaning the FLX-24 pixel• Cleaning the FLX-HUB• Replacing the FLX-NNI Controller

R59770420 FLX-24 21/12/2009 53

5. Maintenance

5.1 Cleaning the FLX-24 pixel

CAUTION: Do not use industrial grease removers. Use only materials or chemicals that are inert, nonabrasive,noncorrosive and non marking.

CAUTION: Do not use a hard bristled brush.

Necessary tools• Soft brush.• Clean cloth.• FLX-24 connector string.

How to clean the FLX-24 pixel?1. Plug the FLX-24 pixel(s) on the connector string to seal off the power/data socket of the pixel. This is necessary to protect theelectronic parts inside the unit.

2. Clean the outside of the FLX-24 pixel with a soft brush and some water.Caution: Do not submerge the FLX-24 pixel(s) into water or other liquids.

3. Wipe dry the FLX-24 pixel(s) using a clean cloth.

Always clean all FLX-24 pixels of the system to avoid brightness differences between cleaned and uncleanedFLX-24 pixels.

54 R59770420 FLX-24 21/12/2009

5. Maintenance

5.2 Cleaning the FLX-HUB

CAUTION: Do not use industrial grease removers. Use only materials or chemicals that are inert, nonabrasive,noncorrosive and non-marking.

CAUTION: Do not use a hard bristled brush.

Necessary tools• Soft brush.• Clean cloth.• FLX power cable.• FLX data cable with IP66 protection shells.

How to clean the FLX-HUB?1. Connect the FLX power cable with the FLX-HUB. This is necessary to protect the electronic parts inside the unit.

2. Connect the FLX data cable, which has IP66 protection shells, with the data input port (RJ45) of the FLX-HUB. This is necessaryto protect the electronic parts inside the unit.

3. Clean the outside of the FLX-HUB with a soft brush and some water.Caution: Do not submerge the FLX-HUB into water or other liquids.

4. Wipe dry the FLX-HUB using a clean cloth.

5. Disconnect the FLX power cable and the FLX data cable from the FLX-HUB.

R59770420 FLX-24 21/12/2009 55

5. Maintenance

5.3 Replacing the FLX-NNI Controller

What has to be done?The FLX-NNI Controller has to be replaced and the settings of the original FLX-NNI Controller have to be ’restored’ into the newFLX-NNI Controller. The result is an image on the screen which is exactly the same as before. In other words, no ’Init replaced’ or’Re-detection’ with the Director toolset has to be done.

The option ’Restore settings’ is possible because the FLX-NNI Controller sends every 5 minutes all settingsof the FLX-NNI Controller to the flash memory of all connected FLX-HUB units. This way, a backup is made ofthe FLX-NNI Controller settings (Address, Board serial, Ctrl serial, Gamma, Contrast, etc. Excluding the pixelstring configuration map).

A backup is made of the ’pixel string configuration map’ during the upload of the design in the FLX-NNI Con-troller with the Director toolset. This backup is stored in the flash memory of the first detected FLX-HUB. So,only one of the connected FLX-HUB units contains the backup of the pixel string configuration map. Thismeans that you have to select this FLX-HUB which contains the backup of the map to restore all the informa-tion (map + settings). Otherwise, only the FLX-NNI Controller settings will be restored.

The ’Restore settings’ option has to be activated within 5 minutes after the power is switched on of the newFLX-NNI Controller. Otherwise, the new FLX-NNI Controller will overwrite the stored settings on all connectedFLX-HUB units with its settings. This will make the pixel string configuration map unavailable for restoring.

How to replace the FLX-NNI Controller?1. Switch off the power of the FLX-NNI Controller which you want to replace.

2. Disconnect all network cables from the data output ports (RJ45) of the FLX-NNI Controller.Tip: Mark the network cables, prior to disconnecting, from 1 to 8 according the data output ports.

3. Disconnect the data cables from the data IN and TRU ports of the FLX-NNI Controller.

4. Disconnect the power cable from the power input socket at the rear of the FLX-NNI Controller.

5. Replace the FLX-NNI Controller and reconnect the power cable. Do not switch on!

6. Reconnect the data cables with the data IN and TRU ports of the FLX-NNI Controller.

7. Reconnect all network cables with the data output ports (RJ45) of the FLX-NNI Controller.

8. Switch on the power of the FLX-NNI Controller and start the ’Restore settings’ procedure within 5 minutes. Do this by brows-ing in the user interface of the FLX-NNI Controller to BARCO FLX ► This controller ► Restore settings and then start theprocedure by selecting the option ► Restore now.Note: By default the FLX-HUB is selected which contains the backup of the pixel string configuration map as well. Do not select

another FLX-HUB.

As a result the settings and map are retrieved from the connected FLX-HUB.

56 R59770420 FLX-24 21/12/2009

A. Dimensions

A. DIMENSIONS

About this chapterThis chapter contains mechanical drawings with the most important dimensions of the FLX components.

Overview

• Dimensions of the FLX-24 pixel• Dimensions of the FLX-24 adapter cable• Dimensions of the FLX-S Strips• Dimensions of the FLX-NNI Controller• Dimensions of the FLX-HUB• Dimensions of the FLX-HUB fixed bracket• Dimensions of the FLX Power Chassis DPR-2700

R59770420 FLX-24 21/12/2009 57

A. Dimensions

A.1 Dimensions of the FLX-24 pixel

Dimensions

513

,915,416,4

Ø10,76°

Ø19Ø23,03

Ø24

Image A-1Dimensions given in millimeters.

58 R59770420 FLX-24 21/12/2009

A. Dimensions

A.2 Dimensions of the FLX-24 adapter cable

Dimensions FLX-24 adapter cable

Image A-2Dimensions given in millimeters.

R59770420 FLX-24 21/12/2009 59

A. Dimensions

A.3 Dimensions of the FLX-S Strips

Dimensions FLX-S25 Strip

312,5

31 x 25 = 775

312,5

799

25

30

31,7

Image A-3Dimensions given in millimeters.

Dimensions FLX-S50 Strip

15 x 50 = 75050

312,5312,5

799 30

31,7

Image A-4Dimensions given in millimeters.

60 R59770420 FLX-24 21/12/2009

A. Dimensions

A.4 Dimensions of the FLX-NNI ControllerDimensions

465

360 160

483

435

420

76,2

217,

1

132,

421

1,5

215,

1

57,4

39 35,5

10

Image A-5Dimensions given in millimeters.

R59770420 FLX-24 21/12/2009 61

A. Dimensions

A.5 Dimensions of the FLX-HUBDimensions

215,17 80,5 14,8

109 36,35

85,2

4

Image A-6Dimensions given in millimeters.

62 R59770420 FLX-24 21/12/2009

A. Dimensions

A.6 Dimensions of the FLX-HUB fixed bracketDimensions

45

Ø10,5 (2x)

Ø6,5 (4x)

250

277

295

4469.587.5

Image A-7Dimensions given in millimeters.

R59770420 FLX-24 21/12/2009 63

A. Dimensions

A.7 Dimensions of the FLX Power Chassis DPR-2700Dimensions

435,4

465,2 349,4

482,6

340,3

266

43,3

26,8

332,

1

Image A-8Dimensions given in millimeters.

64 R59770420 FLX-24 21/12/2009

B. Specifications

B. SPECIFICATIONS

Overview

• FLX-24 specifications• Weight of individual parts of an FLX system

R59770420 FLX-24 21/12/2009 65

B. Specifications

B.1 FLX-24 specifications

SpecificationsAccess front or rear

Brightness 3.000 mcd

Calibration batch-to-batch correction

Color depth 16-bit/color

Default cable string 16 pixels, 130 mm pitch, interconnectable

64 pixels, 130 mm pitch, interconnectable

Diameter 24 mm

Height 31 mm (inl. socket)

LED type 3-in-1 Full Color SMD

Light Output 11 lumens

max. number of pixels on 1 cable 256

Pixel mount External spring clip to front

Protection rating IP66 (rating when mated)

Socket mount M3 threat in socket

Viewing angle 140 deg. (horizontal and vertical)

Weight 30 g (incl. socket and 130 mm cable)

66 R59770420 FLX-24 21/12/2009

B. Specifications

B.2 Weight of individual parts of an FLX system

Weight of individual partsFLX-24 pixel (incl. socket and 130 mm cable) 30 g.

FLX-HUB 1,5 kg.

FLX-NNI Controller 3,7 kg.

FLX Power Chassis DPR-2700 (without rectifiers) 15 kg.

FLX Power Rectifier DPR-2700 2 kg.

FLX Power Chassis DPR-2700 (with rectifiers) 27 kg.

R59770420 FLX-24 21/12/2009 67

B. Specifications

68 R59770420 FLX-24 21/12/2009

C. Order info

C. ORDER INFO

About this chapterThis chapter contains the order numbers of all available FLX parts.

Overview

• Order info list

R59770420 FLX-24 21/12/2009 69

C. Order info

C.1 Order info listOrder infoOrder info Description Comments

R9052800B256 FLX-24 pixel modules. Box of 256 pieces.

R9899549 FLX-24 Connector string 16 connections at 160 mm pitch Bag of 1.

R9899550 FLX-24 Connector string 64 connections at 160 mm pitch Bag of 1.

R9899555B16 FLX-S25 Strip for 32 FLX-24 pixels at 25 mm pitch Box of 16 pieces.

R9899556B16 FLX-S50 Strip for 16 FLX-24 pixels at 50 mm pitch Box of 16 pieces.

R9899548B64 FLX-24 Dummy Plug (Bridge connector) Bag of 64 pieces.

R9899565B64 FLX-24 Cut-out cover Box of 64 pieces.

R9899553B8 FLX-24 Converter cable for in front of strings Bag of 8 pieces.

R9899498B16 FLX-24 String end protection cap Bag of 16 pieces.

R9899552 FLX-24 Extension cable 2 meter. Bag of 1.

R9899561 FLX-24 Extension cable 5 meter. Bag of 1.

R9856090 FLX-HUB boxkit (2 HUB units) 19" bracket, 2 truss kits, 2 datacables of 1m with shells included.

R9856100 FLX-HUB output extension cable 2 meter. Bag of 1.

R9856110 FLX-HUB output extension cable 5 meter. Bag of 1.

R9856120 FLX-HUB output extension cable 10 meter. Bag of 1.

R9856130 FLX-HUB output extension cable 20 meter. Bag of 1.

R9863020 FLX-HUB rental bracket (quick mount). 2 pieces.

R9863030 FLX-HUB fixed install bracket. 4 pieces.

R9899431 FLX Power Chassis DPR-2700. Up to 16kW, dual output. Without rectifiers.

R9899432 FLX Power Rectifier DPR-2700 unit. 2.7kW.

R9899434 FLX-Power Cable 5 meter. 1 piece in cardboard box.

R9899435 FLX-Power Cable 25 meter. 1 piece in cardboard box.

R9899433 FLX-Power Splitter Cable (1 to 4) 1 piece in cardboard box.

R9856150 FLX-Power Connector Male. Bag of 1.

R9856160 FLX-Power Connector Female. Bag of 1.

R9856080 FLX-NNI Controller. Power cord & NNI data cable of 1meter included.

R9854800 HDMI Data Cable (1 meter) with latch. 5 pieces.

R9854820 HDMI Data Cable (1 meter) with latch. 10 pieces.

R9854790 HDMI Data Cable (5 meter) with latch. 5 pieces.

R9854810 HDMI Data Cable (7,5 meter) with latch. 10 pieces.

R9854860 HDMI Data Cable (10 meter) with latch. 5 pieces.

R9899436 FLX-Data Cable with IP66 protection shells 20 meter. Bag of 1 piece.

R9899437 FLX-Data Cable with IP66 protection shells 50 meter. Bag of 1 piece.

R9899438 FLX-Data Cable with IP66 protection shells 100 meter. Bag of 1 piece.

R9899496B16 FLX-HUB output protection cover. Bag of 16 pieces.

R9856140B10 FLX-Date Cable protection RJ45 IP66 shell (LTW). Bag of 10 pieces.

70 R59770420 FLX-24 21/12/2009

Index

INDEXAAddress 25All controllers 23

CCabling 45System 45

Cleaning 54–55FLX-24 pixel 54FLX-HUB 55

Components 13Contrast 23Contrast (this) 24Contrast LCD 25Controller (this) 24Controllers (all) 23

DDefault config 26Digitizer 39–40Dimensions 57–64DPR-2700 64Fixed bracket 63FLX-24 adapter cable 59FLX-24 pixel 58FLX-HUB 62FLX-NNI Controller 61FLX-S Strips 60

DPR-2700 34, 64Dimensions 64

FFixed bracket 63Dimensions 63

FLX-24 66Specification 66

FLX-24 adapter cable 59Dimensions 59

FLX-24 pixel 54, 58Cleaning 54Dimensions 58

FLX-24 Pixel 16FLX-HUB 30, 55, 62Cleaning 55Dimensions 62

FLX-NNI Controller 20, 61Dimensions 61

FLX-S Strips 60Dimensions 60

GGamma 23Gamma (this) 24

HHUBs 28Info 28Patterns 28Power off 28Power on 28

IInfo 25

Install 43–44, 51Process 44RJ45 shells 51

LLCD contrast 25Link Errors 26Local patterns 24

MMaintenance 53Menu 22Menu functionality 22Messages 28Mount 46–47, 49–5019” bracket 50Fixed bracket 49FLX-24 46Rental bracket 47

NNavigation 22

OOrder info 69–70Overview 41Control software 41

PPatterns 23Patterns (local) 24Popup message 28Power System 34Proper usage 8PSU 34

RReplace 56FLX-NNI Controller 56

Requirements 9–12Electrical 11Mechanical 10Software 12

Restore 27Root menu 22

SSafety 3–7DPR-2700 7Guidelines 4Instructions 5Warnings 6–7

Software 12System requirements 12

Specification 66FLX-24 66

Specifications 65String config 26Default config 26

System 45Cabling 45

System overview 14

R59770420 FLX-24 21/12/2009 71

Index

TThis controller 24

UUser interface 22

WWeight 67Parts 67

72 R59770420 FLX-24 21/12/2009