Post on 30-Mar-2023
STC TEST REPORT Date: 2016-05-04 Page 1 of 7
No.: SP125036
STC (Shanghai) Company Limited No.130, Huashen Road, Waigaoqiao Free Trade Zone, Shanghai, China (Zip code: 200131)
Tel: (86 21) 52198248 Fax: (86 21) 52198249 Homepage:www.shstc.org Email:shstc@shstc.org This report shall not be reproduced unless with prior written approval from STC (Shanghai ) Company Limited.
For conditions of Issuance of this test report, Please refer to the overleaf or homepage
Applicant :
Description of Samples : One (1) group of submitted samples said to be:
Date Samples Received : 2016-04-28
Date Tested : 2016-04-28 to 2016-05-12
Investigation Requested : 1. 84/500/EEC & 2005/31/EC ceramic articles intended to come into contact with foodstuffs: determination of the release of Lead and
Cadmium from ceramic ware.
2. Lead and Cadmium Released from Lip and Rim Area.
Conclusion : 1. The test result(s) of the submitted sample(s) complied with the test
requirement of 84/500/EEC & 2005/31/EC ceramic articles intended to
come into contact with foodstuffs: determination of the release of Lead
and Cadmium from ceramic ware.
HE Lijie, Bill
For and on behalf of
STC (Shanghai) Company Limited
STC (Shanghai) Company Limited No.130, Huashen Road, Waigaoqiao Free Trade Zone, Shanghai, China (Zip code: 200131)
Tel: (86 21) 52198248 Fax: (86 21) 52198249 Homepage:www.shstc.org Email:shstc@shstc.org This report shall not be reproduced unless with prior written approval from STC (Shanghai ) Company Limited.
For conditions of Issuance of this test report, Please refer to the overleaf or homepage
STC TEST REPORT Date: 2016-05-04 Page 2 of 7
No.: SP125036
TEST RESULTS:
1. Ceramic Articles Intended to Come into Contact with Foodstuffs: Determination of the
Release of Lead and Cadmium from Ceramic Ware.
1.1 Determination of the Release of Lead and Cadmium from ceramic ware
Ref: 84/500/EEC & 2005/31/EC
Test Method: EN 1388-1:1996
Sample Identity Colour / Component
1 CX1430-99(teapot)
Specimen(s) Leachable lead Leachable cadmium Volume of acid used
(1) <0.1 mg/L <0.01 mg/L 443 mL
(2) <0.1 mg/L <0.01 mg/L 443 mL
(3) <0.1 mg/L <0.01 mg/L 443 mL
(4) <0.1 mg/L <0.01 mg/L 443 mL
Average: <0.1 mg/L <0.01 mg/L 443 mL
Classification: Category 2
Limit 4.0 mg/L 0.3 mg/L -
Notes: 1. mg/L denotes milligram per litre.
2. < denotes less than.
3. Limit is quoted from category 2 in 84/500/EEC & 2005/31/EC.
1.2 Determination of the Release of Lead and Cadmium from ceramic ware
Ref: 84/500/EEC & 2005/31/EC Test Method: EN 1388-1:1996
Sample Identity Colour / Component
1 CX1430-99(cover)
Specimen(s) Leachable lead Leachable cadmium Volume of acid used
(1) <0.1 mg/L <0.01 mg/L 32 mL
(2) <0.1 mg/L <0.01 mg/L 32 mL
(3) <0.1 mg/L <0.01 mg/L 32 mL
(4) <0.1 mg/L <0.01 mg/L 32 mL
Average: <0.1 mg/L <0.01 mg/L 32 mL
Classification: Category 2
Limit 4.0 mg/L 0.3 mg/L -
Notes: 1. mg/L denotes milligram per litre.
2. < denotes less than.
3. Limit is quoted from category 2 in 84/500/EEC & 2005/31/EC.
STC (Shanghai) Company Limited No.130, Huashen Road, Waigaoqiao Free Trade Zone, Shanghai, China (Zip code: 200131)
Tel: (86 21) 52198248 Fax: (86 21) 52198249 Homepage:www.shstc.org Email:shstc@shstc.org This report shall not be reproduced unless with prior written approval from STC (Shanghai ) Company Limited.
For conditions of Issuance of this test report, Please refer to the overleaf or homepage
STC TEST REPORT Date: 2016-05-04 Page 3 of 7
No.: SP125036
TEST RESULTS:
1.3 Determination of the Release of Lead and Cadmium from ceramic ware
Ref: 84/500/EEC & 2005/31/EC
Test Method: EN 1388-1:1996
Sample Identity Colour / Component 1 CX1430-99(cup)
Specimen(s) Leachable lead Leachable cadmium Volume of acid used
(1) <0.1 mg/L <0.01 mg/L 295 mL
(2) <0.1 mg/L <0.01 mg/L 295 mL
(3) <0.1 mg/L <0.01 mg/L 295 mL
(4) <0.1 mg/L <0.01 mg/L 295 mL
Average: <0.1 mg/L <0.01 mg/L 295 mL
Classification: Category 2
Limit 4.0 mg/L 0.3 mg/L -
Notes: 1. mg/L denotes milligram per litre.
2. < denotes less than.
3. Limit is quoted from category 2 in 84/500/EEC & 2005/31/EC.
1.4 Determination of the Release of Lead and Cadmium from ceramic ware
Ref: 84/500/EEC & 2005/31/EC
Test Method: EN 1388-1:1996
Sample Identity Colour / Component 1 CX1429-99(cup)
Specimen(s) Leachable lead Leachable cadmium Volume of acid used
(1) <0.1 mg/L <0.01 mg/L 200 mL
(2) <0.1 mg/L <0.01 mg/L 200 mL
(3) <0.1 mg/L <0.01 mg/L 200 mL
(4) <0.1 mg/L <0.01 mg/L 200 mL
Average: <0.1 mg/L <0.01 mg/L 200 mL
Classification: Category 2
Limit 4.0 mg/L 0.3 mg/L -
Notes: 1. mg/L denotes milligram per litre.
2. < denotes less than.
3. Limit is quoted from category 2 in 84/500/EEC & 2005/31/EC.
STC (Shanghai) Company Limited No.130, Huashen Road, Waigaoqiao Free Trade Zone, Shanghai, China (Zip code: 200131)
Tel: (86 21) 52198248 Fax: (86 21) 52198249 Homepage:www.shstc.org Email:shstc@shstc.org This report shall not be reproduced unless with prior written approval from STC (Shanghai ) Company Limited.
For conditions of Issuance of this test report, Please refer to the overleaf or homepage
STC TEST REPORT Date: 2016-05-04 Page 4 of 7
No.: SP125036
TEST RESULTS:
1.5 Determination of the Release of Lead and Cadmium from ceramic ware
Ref: 84/500/EEC & 2005/31/EC
Test Method: EN 1388-1:1996
Sample Identity Colour / Component 1 CX1429-99(dish)
Specimen(s) Leachable lead Leachable cadmium Volume of acid used
(1) <0.1 mg/dm² <0.01 mg/dm² -
(2) <0.1 mg/dm² <0.01 mg/dm² -
(3) <0.1 mg/dm² <0.01 mg/dm² -
(4) <0.1 mg/dm² <0.01 mg/dm² -
Average: <0.1 mg/dm² <0.01 mg/dm² -
Classification: Category1
Limit 0.8 mg/dm² 0.07 mg/dm² -
Notes: 1. mg/L denotes milligram per litre.
2. < denotes less than.
3. Limit is quoted from category 1 in 84/500/EEC & 2005/31/EC.
1.6 Determination of the Release of Lead and Cadmium from ceramic ware
Ref: 84/500/EEC & 2005/31/EC
Test Method: EN 1388-1:1996
Sample Identity Colour / Component 1 CX1431-99(cup)
Specimen(s) Leachable lead Leachable cadmium Volume of acid used
(1) <0.1 mg/L <0.01 mg/L 276 mL
(2) <0.1 mg/L <0.01 mg/L 276 mL
(3) <0.1 mg/L <0.01 mg/L 276 mL
(4) <0.1 mg/L <0.01 mg/L 276 mL
Average: <0.1 mg/L <0.01 mg/L 276 mL
Classification: Category 2
Limit 4.0 mg/L 0.3 mg/L -
Notes: 1. mg/L denotes milligram per litre.
2. < denotes less than.
3. Limit is quoted from category 2 in 84/500/EEC & 2005/31/EC.
STC (Shanghai) Company Limited No.130, Huashen Road, Waigaoqiao Free Trade Zone, Shanghai, China (Zip code: 200131)
Tel: (86 21) 52198248 Fax: (86 21) 52198249 Homepage:www.shstc.org Email:shstc@shstc.org This report shall not be reproduced unless with prior written approval from STC (Shanghai ) Company Limited.
For conditions of Issuance of this test report, Please refer to the overleaf or homepage
STC TEST REPORT Date: 2016-05-04 Page 5 of 7
No.: SP125036
TEST RESULTS:
2.1. Lead and Cadmium Released from Lip and Rim Area
Ref.: ASTM C927-80(Reapproved 2014)
Sample Identity Colour / Component 1 CX1430-99(cup)
Specimen(s) Leachable lead Leachable cadmium Volume of acid used
(1) <0.1 mg/L <0.01 mg/L 335mL
(2) <0.1 mg/L <0.01 mg/L 335mL
(3) <0.1 mg/L <0.01 mg/L 335mL
(4) <0.1 mg/L <0.01 mg/L 335mL
(5) <0.1 mg/L <0.01 mg/L 335mL
(6) <0.1 mg/L <0.01 mg/L 335mL
Average: <0.1 mg/L <0.01 mg/L 335mL
Limit* <4 mg/L <0.4 mg/L --
Notes: 1. mg/L denotes milligram per litre.
2. < denotes less than.
3. *Limit reference to Society of Glass and Ceramic Decorators (SGCD).
2.2. Lead and Cadmium Released from Lip and Rim Area
Ref.: ASTM C927-80(Reapproved 2014)
Sample Identity Colour / Component 1 CX1429-99(cup)
Specimen(s) Leachable lead Leachable cadmium Volume of acid used
(1) <0.1 mg/L <0.01 mg/L 126mL
(2) <0.1 mg/L <0.01 mg/L 126mL
(3) <0.1 mg/L <0.01 mg/L 126mL
(4) <0.1 mg/L <0.01 mg/L 126mL
(5) <0.1 mg/L <0.01 mg/L 126mL
(6) <0.1 mg/L <0.01 mg/L 126mL
Average: <0.1 mg/L <0.01 mg/L 126mL
Limit* <4 mg/L <0.4 mg/L --
Notes: 1. mg/L denotes milligram per litre.
2. < denotes less than.
3. *Limit reference to Society of Glass and Ceramic Decorators (SGCD).
STC (Shanghai) Company Limited No.130, Huashen Road, Waigaoqiao Free Trade Zone, Shanghai, China (Zip code: 200131)
Tel: (86 21) 52198248 Fax: (86 21) 52198249 Homepage:www.shstc.org Email:shstc@shstc.org This report shall not be reproduced unless with prior written approval from STC (Shanghai ) Company Limited.
For conditions of Issuance of this test report, Please refer to the overleaf or homepage
STC TEST REPORT Date: 2016-05-04 Page 6 of 7
No.: SP125036
TEST RESULTS:
2.3. Lead and Cadmium Released from Lip and Rim Area
Ref.: ASTM C927-80(Reapproved 2014)
Sample Identity Colour / Component 1 CX1431-99(cup)
Specimen(s) Leachable lead Leachable cadmium Volume of acid used
(1) <0.1 mg/L <0.01 mg/L 100mL
(2) <0.1 mg/L <0.01 mg/L 100mL
(3) <0.1 mg/L <0.01 mg/L 100mL
(4) <0.1 mg/L <0.01 mg/L 100mL
(5) <0.1 mg/L <0.01 mg/L 100mL
(6) <0.1 mg/L <0.01 mg/L 100mL
Average: <0.1 mg/L <0.01 mg/L 100mL
Limit* <4 mg/L <0.4 mg/L --
Notes: 1. mg/L denotes milligram per litre.
2. < denotes less than.
3. *Limit reference to Society of Glass and Ceramic Decorators (SGCD).
STC (Shanghai) Company Limited No.130, Huashen Road, Waigaoqiao Free Trade Zone, Shanghai, China (Zip code: 200131)
Tel: (86 21) 52198248 Fax: (86 21) 52198249 Homepage:www.shstc.org Email:shstc@shstc.org This report shall not be reproduced unless with prior written approval from STC (Shanghai ) Company Limited.
For conditions of Issuance of this test report, Please refer to the overleaf or homepage
STC TEST REPORT Date: 2016-05-04 Page 7 of 7
No.: SP125036
The photo of submitted samples
********** End of Test Report **********
STC TEST REPORT Date: 2016-06-08 Page 1 of 4
No.: SP125038
STC (Shanghai) Company Limited No.130, Huashen Road, Waigaoqiao Free Trade Zone, Shanghai, China (Zip code: 200131)
Tel: (86 21) 52198248 Fax: (86 21) 52198249 Homepage:www.shstc.org Email:shstc@shstc.org This report shall not be reproduced unless with prior written approval from STC (Shanghai ) Company Limited.
For conditions of Issuance of this test report, Please refer to the overleaf or homepage
Applicant :
Description of Samples : One (1) group of submitted samples said to be:
Date Samples Received : 2016-04-28
Date Tested : 2016-04-28 to 2016-06-07
Requirements Conclusion 1. Extractable Heavy Metals - (EC) No 1935/2004 PASS
2. Migration Of Heavy Metal - TECHNICAL GUIDE ON METAL AND ALLOYS USED IN FOOD CONTACT MATERILAS OF COUNCIL OF EUROPE RESOLUTION CM/RES (2013) 9
PASS
HE Lijie, Bill
For and on behalf of
STC (Shanghai) Company Limited
STC (Shanghai) Company Limited No.130, Huashen Road, Waigaoqiao Free Trade Zone, Shanghai, China (Zip code: 200131)
Tel: (86 21) 52198248 Fax: (86 21) 52198249 Homepage:www.shstc.org Email:shstc@shstc.org This report shall not be reproduced unless with prior written approval from STC (Shanghai ) Company Limited.
For conditions of Issuance of this test report, Please refer to the overleaf or homepage
STC TEST REPORT Date: 2016-06-08 Page 2 of 4
No.: SP125038
TEST RESULTS:
1. Extractable Heavy Metals - (EC) No 1935/2004
Method Used: Extracted the sample in 3%(w/v) acetic acid at 70C for 2 hour, analyzed by ICP-AES
Sample Identity Colour / Component Style
1 Stainless steel spoon -
2 Stainless steel tea ball -
Results
1 2
Note(s): - mg/dm2 = milligram per square decimeter Method dctected limit (mg/dm2): - Pb 0.002, Cd 0.002, Cr 0.002, Ni 0.002, Cu 0.002, Co 0.002, Sb 0.002
Test Item(s) Unit
Maximum Allowable Limit
Lead (Pb) mg/dm2 ND ND 0.01
Cadmium (Cd) mg/dm2 ND ND 0.005
Chromium (Cr) mg/dm2 ND ND 0.4
Nickel (Ni) mg/dm2 ND ND 0.1
Copper (Cu) mg/dm2 ND ND 0.5
Cobalt (Co) mg/dm2 ND ND 0.1
Antimony (Sb) mg/dm2 ND ND 0.005
Conclusion - Pass Pass
STC (Shanghai) Company Limited No.130, Huashen Road, Waigaoqiao Free Trade Zone, Shanghai, China (Zip code: 200131)
Tel: (86 21) 52198248 Fax: (86 21) 52198249 Homepage:www.shstc.org Email:shstc@shstc.org This report shall not be reproduced unless with prior written approval from STC (Shanghai ) Company Limited.
For conditions of Issuance of this test report, Please refer to the overleaf or homepage
STC TEST REPORT Date: 2016-06-08 Page 3 of 4
No.: SP125038
TEST RESULTS:
2. Migration Of Heavy Metal - TECHNICAL GUIDE ON METAL AND ALLOYS USED IN FOOD CONTACT MATERILAS OF COUNCIL OF EUROPE RESOLUTION CM/RES (2013) 9 Method Used: With relerence to EN 13130-1:2004, Analysis was performed by Inductively Coupled Argon Plasma Atomic Emission Spectrophotometer and Graphite Furnace Atomic Absorption Spectrometry Simulant Used: 0.5% citric acid (w/w) in aqueous solution Test Condition: 100°C for 2 hours The radio of surface area to volume: 1dm2/ kg
Sample Identity Colour / Component Style 1 Stainless steel spoon -
2 Stainless steel tea ball -
Test Item(s)
Unit
1st+2nd Migration 3rd Migration
MDL Result Maximum
Allowable Limit
Result Maximum Allowable
Limit 1 2 1 2
Aluminium(Al) mg/kg ND ND 35 ND ND 5 0.2 Antimony(Sb) mg/kg ND ND 0.28 ND ND 0.04 0.02 Chromium(Cr) mg/kg ND 0.14 1.75 ND ND 0.25 0.1 Cobalt(Co) mg/kg ND ND 0.14 ND ND 0.02 0.01
Copper(Cu) mg/kg ND ND 28 ND ND 4 0.1 Iron(Fe) mg/kg 1.30 3.15 280 ND 0.26 40 0.25
Manganese(Mn) mg/kg ND ND 12.6 ND ND 1.8 0.25 Molybdenum(Mo) mg/kg ND ND 0.84 ND ND 0.12 0.02 Nickel(Ni) mg/kg ND ND 0.98 ND ND 0.14 0.05 Silver(Ag) mg/kg ND ND 0.56 ND ND 0.08 0.03
Tin(Sn) mg/kg ND ND 700 ND ND 100 5 Vanadium(V) mg/kg ND ND 0.07 ND ND 0.01 0.005
Zinc(Zn) mg/kg ND ND 35 ND ND 5 1 Arsenic(As) mg/kg ND ND 0.014 ND ND 0.002 0.001 Barium(Ba) mg/kg ND ND 8.4 ND ND 1.2 0.25 Beryllium(Be) mg/kg ND ND 0.07 ND ND 0.01 0.005
Cadmium(Cd) mg/kg ND ND 0.035 ND ND 0.005 0.002 Lead(Pb) mg/kg ND ND 0.07 ND ND 0.01 0.005
Lithium(Li) mg/kg ND ND 0.336 ND ND 0.048 0.02 Mercury(Hg) mg/kg ND ND 0.021 ND ND 0.003 0.002 Thallium(Tl) mg/kg ND ND 0.0007 ND ND 0.0001 0.0001 Magnesium(Mg) mg/kg ND ND - ND ND - 0.5
Titanium (Ti) mg/kg ND ND - ND ND - 0.5 Conclusion - Pass -
Note(s): - ND = Not Detected
- MDL = Method Detected Limit
- mg/kg = milligram(s) per kilogram = ppm = part(s) per million
STC (Shanghai) Company Limited No.130, Huashen Road, Waigaoqiao Free Trade Zone, Shanghai, China (Zip code: 200131)
Tel: (86 21) 52198248 Fax: (86 21) 52198249 Homepage:www.shstc.org Email:shstc@shstc.org This report shall not be reproduced unless with prior written approval from STC (Shanghai ) Company Limited.
For conditions of Issuance of this test report, Please refer to the overleaf or homepage
STC TEST REPORT Date: 2016-06-08 Page 4 of 4
No.: SP125038
The photo of submitted samples
********** End of Test Report **********