1101 W. 13th Street Riviera Beach, Florida 33404(561) 848-1826www.rgf.com/afl-industries
Large, unpredictable oil spills can defeat even the most conservativelydesigned pollution control systems. The OSV is an economical option usedto confine hydrocarbon spills to the premises for safe disposal.to confine hydrocarbon spills to the premises for safe disposal. AFL's OSV is fabricated from either non-corrosive Stainless or PVC and has only one moving part, the ballasted float. When an oil spill occurs, the float loses buoyancy as the oil level increases until it finally seats on the discharge port, closing and confining the spill.
Dependable Gravity OperationLarge Flow CapacityNo Power RequirementOutlet Sizes: 4” / 6” / 8” / 10” / 12”
Single Moving PartSelf-Opening (Slave Valve Option)Corrosion Resistant ConstructionCustom Outlet ConnectionsEN
GINEERING A BETTER ENVIRONMENT
Doc # AFL-LIT-0001 Rev A
0
OIL STOP VALVE (OSV) • SPECIFICATION SHEET
SST. CABLE W/ HANDLE FOR MANUAL OPENING
SS FLOAT W/TEFLON SEAT
WATER INLET
OSV Options
(/) 1" VENT PIPE (NOT SUPPLIED BY AFL)
(/) l" VENT CONNECTION
PIPE BOOT
OUTLET
(/) l /2" MOUNTING HOLES (4) PLACES
SLAVE VALVE - Recommended option to ensure automatic valve re-opening if residual water evaporates
FREEZE PROTECTION - Eliminates sump water freezing where environmental conditions exist
How to select the right valve type and size for your application
PVC
PVC models represent an economical option to
prevent bulk hydrocarbon spills. Corrosion-resistant
PVC construction is ideal for warmer climates.
STAINLESS STEEL
Stainless steel models are recommended in colder
climates or where greater durability is desired.
STAINLESS STEEL EXTENDED OUTLET
Stainless steel extended outlet models reduce fire risk by
extending the outlet pipe through the sump wall so there
is no connection inside the sump to burn and fail.
VALVE SIZE CONSTRUCTION {MAX) FLOW RATE 4" Diameter PVC/SS 160 GPM
6" Diameter PVC/SS 360 GPM
8" Diameter PVC/SS 600 GPM 1 O" Diameter ss 900 GPM 12" Diameter ss 1400 GPM
WARNING: Exceeding these fiow rates may cause
premature closing.
AFL recommends a 4ft diameter catch basin for
the OSV-4 and OSV-6, and a 5ft diameter basin
for the OSV-8, OSV-10 and OSV-12
Doc # AFL-LIT-0001 Rev A ISO 9001:2015 CERTIFIED COMPANY
VTC (OIL WATER SEPARATOR) • SPECIFICATION SHEET
A Division of RGF Environmental Group, Inc.
1101 W. 13th Street
VTC Series - Vertical Tube Coalescing Oil Water Separator Fiberglass, Stainless Steel and Carbon Steel
Riviera Beach, Florida 33404
(561) 848-1826
www.rgf.com/afl-industri es
,Q \ ,
0 0
0
Flow Rates 0-2400 GPM in a Single Tank Separate hydrocarbons from wastewater and storm water
:AFt
vrC-Joo AtJerglass
Above Ground
VTC-20 Stainless Steef
Above Ground
The VTC removes 'free' hydrocarbons and settleable solids from industrial waste water and
coolant. In operation, the VTC accepts industrial liquid waste in the inlet chamber where
settleable solids fall to the bottom as sludge for periodic removal. The waste stream then enters
the coalescing separation chamber where AFL's Delta-Tubes inspire laminar flow characteristics
to the liquid as it passes through the separator. The result is a liquid more responsive to gravity
separation. The Delta-Tubes primarily provide a coalescing medium for oil globules. Oleophilic in
nature, the Delta-Tubes attract small oil globules which coalesce to larger globules, increasing in
size and buoyancy, then break away to rise to the surface. Floating oil is collected by a Rotary
Pipe Skimmer for collection and disposal in accordance with local regulations.
FEATURES
Reduces free oil content down to <10 ppm
Removes oil droplets >20 micro n
Fiberglass, sta inless and carbon steel
Pre-engineered, ready to install
No power, g ravity flow or fully automated
Conforms to API design standards
Doc# AFL-LIT-OOO2 Rev A ISO 9001:2015 CERTIFIED COMPANY
0
VTC (OIL WATER SEPARATOR) • SPECIFICATION SHEET
SHEEN BAFFLE
ROTARY PIPE SKIMMER
CORROSION RESISTANT FRP CONSTRUCTION
VTC Options Oil Stop Valve Installed
Ladders and Hand Rails
Freeze Protection
Controls and Automation
ADJUSTABLE
WEIR PLATE
DRAIN
WEIR
OIL RETENTION BAFFLE
SLUDGE DRAW-OFF
REMOVABLE VERTICAL TUBE COALESCING MATRIX
CATCH BASIN
Internal Oil Storage
External Oil Storage
Custom Oil Skimmers
Influent and Effluent Pumps
Sludge and Waste Oil Pumps
Fiberglass Construction
Stainless Steel Construction
Carbon Steel Construction
VTC Series - Technical Specifications Model Flow Rate Volume Dimensions Installation
VTC-5-SS 5GPM 34 Gal. 2. 75' X 1.5' X 1.4' H Above
VTC-10-SS 10 GPM 91 Gal. 4' X 2' X 2' H Above
VTC-20-SS 20GPM 290 Gal. 6.4' X 2.7' X 4.4' H Above
VTC-50-SS 50GPM 797 Gal. 6' x 5.5' x 4.4' H Above/Flush/Below
VTC-100 100 GPM 942 Gal. 10.5' X 2.5' X 6.4' H Above/Flush/Below
VTC-200 200 GPM 1,420 Gal. 10.5' X 4.3' X 6.4' H Above/Flush/Below
VTC-300 300 GPM 2,130 Gal. 10.5' x 6.3' x 6.4' H Above/Flush/Below
VTC-400 400 GPM 2,840 Gal. 10.5' x 8.4' x 6.4' H Above/Flush/Below
VTC-500 500 GPM 3,560 Gal. 10.5' X 10' X 6.4' H Above/Flush/Below
VTC-600 to 2400 Flow rates from 600 to 2,400 gpm in a single unit Above/Flush/Below
AFL's VTC series oil water separators conform to API Standard 421 for the Design and Operation of Oil Water Separators.
Doc# AFL-LIT-0002 Rev A ISO 9001:2015 CERTIFIED COMPANY
CVF (OIL WATER SEPARATOR) • SPECIFICATION SHEET
A Division of RGF Environmental Group, Inc.
1101 W. 13th Street
CVF Series - Vertical Tube Coalescing Oil Water Separator Separates hydrocarbons from wastewater and storm water Cylindrical Fiberglass Tank Riviera Beach, Florida 33404
(561) 848-1826
www.rgf.com/afl-industri es
C
Flow rate from 20 to 100 GPM
11>�■ -
■--E.---
The CVF removes 'free' hydrocarbons and settleable solids from industrial waste water and
coolant. In operation, the CVF accepts industrial liquid waste in the inlet chamber where
settleable solids fall to the bottom as sludge for periodic removal. The waste stream then enters
the coalescing separation chamber where AFL's Delta-Tubes inspire laminar flow characteristics
to the liquid as it passes through the separator. The result is a liquid more responsive to gravity
separation. The Delta-Tubes primarily provide a coalescing medium for oil globules. Oleophilic in
nature, the Delta-Tubes attract small oil globules which coalesce to larger globules, increasing in
size and buoyancy, then break away to rise to the surface. Floating oil is collected by a Rotary
Pipe Skimmer for collection and disposal in accordance with local regulations.
FEATURl:S Reduces free oil content down to <10 ppm
Removes oil droplets >20 micron Corrosive resistant fiberglass construction
Above ground or flush-to-grade installation
Pre-engineered, ready to install
No power, gravity flow or fully automated Conforms to API design standards
Doc# AFL-LIT-0003 Rev A ISO 9001:2015 CERTIFIED COMPANY
"
0
0
CVF (OIL WATER SEPARATOR) • SPECIFICATION SHEET
MANWAY HASP
r-,
MANWAY ACCESS\ OIL RETENTION BAFFLE
LEVEL PROVIS
SWITCH ION / VENT ;\ I i (
ADJUSTABLE W EIR PLATE
INLET
�: 111
CORROS RESISTANT CONSTRUCT
ION FRP ION\
INLET WALL
LJ
I ffi
COALESCING TUBE MATRIX
'"'"[
\ DRAIN .� ]
SLUDGE CATCH BASIN -
CVF Options
�TAAY� PIPE
D SKIMMER +
..,_
., I
DRAIN -
/q I
-
/ V'
r=� 111: Ill
UILl:.I
ALL WEIR W
Oil Stop Valve Installed
Controls and Automation
Freeze Protection
I ntema I Oil Storage
External Oil Storage
Custom Oil Skimmers
Sludge and Waste Oil Pumps
Influent and Effluent Pumps
CVF Series - Technical Specifications Model Flow Rate Volume Dimensions Installation
CVF-4A-305-20-S-0 20GPM 305 Gal. 4.5' Dia. x 3.25' H Above
CVF-4F-305-20-S-0 20GPM 305 Gal. 4.5' Dia. x 3.25' H Flush
CVF-5A-660-50-S-0 50GPM 660 Gal. 5.5' Dia. x 4.5' H Above
CVF-5F-660-50-S-0 50GPM 660 Gal. 5.5' Dia. x 4.5' H Flush
CVF-5A-807-100-S-0 100 GPM 807 Gal. 5.5' Dia. x 5.5' H Above
CVF-5A-807-100-S-0 100 GPM 807 Gal. 5.5' Dia. x 5.5' H Flush
AFL's CVF series oil water separators conform to API Standard 421 for the Design and Operation of
Oil Water Separators.
Doc# AFL-LIT-0003 Rev A ISO 9001:2015 CERTIFIED COMPANY
EGS (OIL WATER SEPARATOR) • SPECIFICATION SHEET
A Division of RGF Environmental Group, Inc.
1101 W. 13th Street
EGS Series - Enhanced Gravity Separator Fiberglass, Stainless Steel and Carbon Steel Flow Rates up to 700 GPM in a Single Tank Riviera Beach, Florida 33404
(561) 848-1826
www.rgf.com/afl-industries Separate solids and oil from wastewater and storm water
The EGS separates heavy solids and oil from industrial wastewater and storm water using
gravity separation. Heavy settleable solids drop out of oily wastewater in the inlet chamber. In
the separating chamber, the oil rises and lighter settleable solids fall. Floating oil collected in the
separating chamber is collected by a rotary pipe skimmer for collection and disposal. A sheen
baffle retains residual floating oil as the treated effluent discharges through the outlet.
Flow rates up to 700 GPM
Above, Below, Flush to Grade
Robust Gravity Separation
No Moving Parts
FEATURES
Corrosion Resistant Construction
Low Maintenance
Exceeds API Design Criteria
Complete Range of Options
Doc #AFL-LIT-0005 Rev A ISO 9001:2015 CERTIFIED COMPANY
('
EGS (OIL WATER SEPARATOR) • SPECIFICATION SHEET
CORROSION RESIST ANT FIBERGLASS ENVELOPE
VTC Options Oil Stop Valve Installed
Ladders and Hand Rails
Freeze Protection
Controls and Automation
ROT ARY PIPE SKIMMER
DELTA-TUBE BAFFLE
PRIMARY SLUDGE BAFFLE
Internal Oil Storage
External Oil Storage
Custom Oil Skimmers
Influent and Effluent Pumps
T-PIPEOUTLET
SHEEN BAFFLE
OIL STOP VAL VE (OPTIONAL)
Sludge and Waste Oil Pumps
Fiberglass Construction
Stainless Steel Construction
Carbon Steel Construction
AFL oil and solids separators are designed in accordance with American Petroleum Institute
(API) criteria for liquid waste. The EGS is a pre-packaged, ready-to-install separation tank
constructed of either fiberglass, stainless steel or carbon steel. AFL's dual-wall fiberglass tank
offers the greatest durability and life expectancy with foam core, 100% composite once-piece
molded construction.
EGS Series - Technical Specifications Model Flow Rate Volume Dimensions Installation
EGS-100 100 GPM 2,610 Gal. 19' x 7' x 5.6' H Above/Flush/Below
EGS-150 150 GPM 3,591 Gal. 26' x 7' x 5.6' H Above/Flush/Below
EGS-200 200 GPM 4,656 Gal. 33.5' x 7' x 5.6' H Above/Flush/Below
EGS-300 300 GPM 6,993 Gal. 49.8' x 7' x 5.6' H Above/Flush/Below
EGS-400 400 GPM 9,345 Gal. 49.8' x 8' x 5.8' H Above/Flush/Below
EGS-500 500 GPM 11,516 Gal. 62.8' x 8' x 5.8' H Above/Flush/Below
EGS-600 600 GPM 14,279 Gal. 60.2' x 1 O' x 5.8' H Above/Flush/Below
EGS-700 700 GPM 16,173 Gal. 69' x 10' x 5.8' H Above/Flush/Below
Doc #AFL-LIT-0005 Rev A ISO 9001:2015 CERTIFIED COMPANY
1101 W. 13th Street Riviera Beach, Florida 33404(561) 848-1826www.rgf.com/afl-industries
ENGINEERING A BETTER ENVIRONMENT
1101 W. 13th Street Riviera Beach, Florida 33404(561) 848-1826www.rgf.com/afl-industries
AFL has developed tube packs to upgrade existing gravity separator used in treating oilywastewater. The principal function of the pack is to provide a coalescing surface on which minute oil globules can agglomerate. The coalesced oil then rises to the surface to be skimmed.
The tube pack makes possible the attainment of one of two goals – or a compromise between them: 1. The oil content of the water can be significantly reduced, or 2. The flow through the separator can be greatly increased without degradation of the oil-separating performance.
The vertically-positioned tubes, made of perforated polypropylene, have oleophilic(oil-attracting) properties. Small, suspended particles of oil agglomerate on the surface and wick up. Or if they become sufficiently large and Buoyant, they break free and rise through the tubes.EN
GINEERING A BETTER ENVIRONMENT
Doc # AFL-LIT-0004 Rev A
('
COALESCING DELTA TUBES· SPECIFICATION SHEET
A tube provides up to five times more coalescing surface than a plate pack. The extra surface
gives oil globules more area on which to collect.
The vertical orientation of the tubes contributes to a more efficient separation. In a plate pack
the rising oil must move against the flow of the influent. With a tube pack, however, the oil is
free to travel a clear upward path to the surface.
A pack consists of modular one-foot welded bundles of tubes. Fiberglass channel and grating
form a cradle to hold the modules in place. Eyebolts at the upper corners of the pack permit
lifting the entire unit for inspection or servicing the separator.
The tubes remove oil globules down to the 20-micron range; this contrasts with the removal of
150 micron globules by gravity separators constructed on API dimensional criteria. In AFL
coalescing separators the tubes typically produce effluents with an oil content of less than
1- mg/ltr.
FEATURES
More efficient than plate packs
Upgrades existing gravity separators
Removes oil down to 20-micron globule size
Typical oil reduction to 10mg/ltr
Available to fit any size gravity separator
VERTICAL TUBE COALESCING PRINCIPLE OF OPERATION
/JEAN �cAuENT
Tubes reduce free oil content
of effluent to 10 mg/ltr or less
because microscopic oil
particles agglomerate on the
surface. The growing oil
globules either wick up or, if
sufficiently buoyant, break
free to rise to the surface.
A single pass of a perforated tube
demonstrates the oleophilic
(oil-attracting) properties of the
material. This reverses the
separator operation where
contaminated water moves past a
battery of tubes.
Tubes are welded in one-foot
square bundles (as above).
Sections of these bundles,
held in place by a cradle, can
easily be lifted out for
vinspection.
Doc #AFL-LIT-0004 Rev A ISO 9001:2015 CERTIFIED COMPANY
Copyright RGF 2013©
The AFL/Clark Oil Stop Valve (OSV) is designed to prevent a major oil spill. The OSV is available from AFL prepackaged in a fiberglass, concrete, stainless, and carbon steel catch basin or as an option on AFL Oil/Water Separators. The OSV is also available separately for installation in existing separators, catch basins or manholes.
A partial listing of companies currently using the AFL/Clark Oil Stop Valve is shown below.
PETROLEUM
Cargill, Inc.
Evergreen Oil, Inc.
GATX Terminals Corp.
Gulf Oil Canada
Imperial Oil Ltd.
Raymer Oil
PULP & PAPER
Mead Paper Co.
Reed Paper Co.
Scott Paper
TRANSPORTATION SERVICES
AIRPORTS
Grumman Aerospace
Washington DC Airport
RAILROADS
Amtrak
Atchison, Topeka & Santa Fe
CSX Railroad
Canadian Pacific RR
Louisville & Nashville RR Co.
Missouri Pacific RR Co.
Via Rail
OTHER
Avis Car rental United Parcel Service
PETROLEUM DISTRIBUTION
Agway Petroleum
Arco
Chevron USA
Cave Fuel Oil Plant
Exxon Co.
Gulf Oil Co.
Louisiana Land & Exploration
Mobil Oil Corp.
Moraine Industries, Inc.
Petrofina
PM Terminals
R.B. Newman Fuel Corp.
Sohio Pipeline Co.
Texaco, Inc.
USER LIST
CHEMICALSAllied ChemicalCargill CorporationJohn E. Green Co.G.D. SearleSearle ChemicalSurpass ChemicalTexas, Inc.
FOODBurger King DistronCargill, Inc.Crispy PizzaFrito-LayProctor & GamblePublicker, Inc.
METALS, FABRICATED PRIMARYCascade SteelGeneral ElectricHuntington Alloys, Inc
MACHINERYChampion Building Products General Electric General MotorsVulcan-Brungar Equipment
MILITARY INSTALLATIONSAnderson AFB/GuamAir National Guard,Suffolk County Airport Westhampton Beach, N.Y.Charleston AFBDavid W. Taylor Naval R&D CenterDepartment of Energy,St. James Terminal, Parish LA.Dyess AFBFt. Lewis, WAGoodfellow AFBFt. Knox Water Pollution AbatementLACV-30 Maint. Facility, Ft. Story, VALake Chicot Pumping StationMcConnel AFBMelville Defense SupplyNaval Air Rework Facility, Norfolk, VAOwens Field Columbia, SCPlattsurgh AFBU.S. Naval Submarine Base, Groton, CT
MILITARY INSTALLATIONS(Continued)U.S. Coast Guard, Aquadilla, PR USCG Helicopter Parking Ramp,Diego GarciaU.S. Coast Guard, Kodiak, Alaska U.S. Navy Trident BaseVermont Air National Guard West Haverstraw Substation Whitman AFB
UTILITIESAbex Corp.B.C. Hydro PlantBonneville Power AdministrationBoston Edison Co.Carolina Power & LightCentral Illinois Public Service Co.Clark ProductsCommonwealth EdisonConsolidated Edison Co. of NY, Inc.Duke EnergyDamon C. Douglas Co.Dayton Power & LightDelmarva PowerEast Kentucky PowerFlorida Power & LightGeorgia Power Co.HydroquebecKansas Power & Light Co. MurrayHydroelectricOregon ElectricPacific Power & LightPanelecPape & SonsPennsylvania Power Co.Philadelphia Electric Co.Portland General ElectricPower Authority of New York PublicService Electric & Gas Puget SoundPower & Light Seattle City LightTennessee Valley Authority VermontElectric Power Co. Virginia Electric& Power Co. Wassaic DevelopmentCenter West Oregon Electric Co-opWestern Farmers Elec. Co-op
800-842-7771www.rgf.com/afl-industries