Dräger X-am® 5600Multi-Gas Detection Device
Featuring an ergonomic design and innovative infrared sensor technology,the Dräger X-am 5600 is the smallest gas detection instrument forthe measurement of up to 6 gases. Ideal for personal monitoringapplications, this robust and water-tight detector provides accurate,reliable measurements of explosive, combustible and toxic gases andvapors as well as oxygen.
D-2
7784
-200
9
Retro reflectors:Easy to find in the dark or in water.
DrägerSensors:Fast, accurate and durable.
A visual life signal indicates the continuous operation of the infrared sensor.
Large display:All readings at one glance.
Safe gas inlet:Gas entry from two sides.
Visual alarm:360° visible alarm.
Benefits
02 | Dräger X-am® 5600
Small yet robust
Small, light and easy to use - the robust and water-tight gas detector X-am 5600 is designed for single-handedoperation in tough industrial environments. Water- and dustproof according to IP 67 and with an integratedrubber boot, the device provides optimal functionality even under harsh conditions.
Durable infrared technology
Thanks to the high stability and a resistance to contamination, Dräger infrared sensors can generally be usedfor up to eight years. This advanced technology reduces the cost of ownership considerably because lessreplacement sensors are needed. In addition, a sensor calibration is only necessary every 12 months whichreduces maintenance costs.
Single or dual sensor - accurate measurement results
The infrared sensor IR Ex allows the measurement of explosive, combustible hydrocarbons in the range of thelower explosive limit. The infrared sensor IR CO2, with a measurement resolution of 0.01 Vol.-%, provides safeand exact measurements as well as a warning against toxic concentrations of carbon dioxide in the ambient air.For those applications where the reliable measurement of explosive substances and CO2 is specifically needed,the advantages of both can be achieved by a dual sensor (Dual IR CO2/Ex).
Also in combination with Hydrogen
Besides hydrocarbons, hydrogen can also be an explosive gas. Because sensors based on infrared technologydo not warn against hydrogen explosion dangers, the gas detector X-am 5600 combines two sensor signals(Infrared Ex and electrochemical H2) for reliable hydrogen detection. The X-am 5600 provides the advantages ofpoison-free technology to be used in areas where, until now, only catalytic Ex sensors have been used.
Various monitoring possibilities
Thanks to the combination of innovative infrared technology and the latest electrochemical Dräger XXSminiature sensors, this 1-to-6 gas detector reliably detects explosive, combustible and harmful concentrations ofO2, Cl2, CO, CO2, H2, H2S, HCN, NH3, NO, NO2, PH3, SO2, O3, Amine, Odorant, COCl2 and organic vapors. Withthe PC software Dräger CC-Vision, the sensors can easily be exchanged, calibrated or converted to meet theneeds of different applications.
Flexible use
An optional external pump which can be operated with hoses up to 30 m or 98 ft. in length is the perfectsolution for pre-entry measurements in tanks or pipelines. To monitor entire areas, the gas detector X-am 5600can be used in combination with the innovative air monitor Dräger X-zone 5000.
Benefits
Dräger X-am® 5600 | 03
Suitable for Ex-Zone 0
The small and reliable gas detector is suitable for use in areas classified as zone 0, which are areas whereexplosive atmospheres are always to be expected.
Area monitoring
In combination with the Dräger X-zone 5000 the gas detector can be used for various area monitoringapplications. Up to 25 Dräger X-zone 5000 units can be automatically interconnected to form a wirelessfenceline. This interconnection of the area monitoring devices allows for the fast securing of larger areas, e.g.pipelines or industrial tanks – even within the scope of industrial shutdowns.
System components
ST-
740-
2006
Dräger Bump Test Station
Easy to use, stand-alone and portable. With the Bump Test Station,functionality tests of gas detection and warning devices can be carriedout easily and quickly.
System components
04 | Dräger X-am® 5600
D-4
7907
-201
2
Dräger X-dock® 5300/6300/6600
The Dräger X-dock® series provides you with full control of yourportable Dräger gas detection instruments. Automatic bump testsand calibrations with reduced test gas consumption and short testingtimes save time and money. Comprehensive documentation andevaluations provide you with a clear overview.
Accessories
D-1
2284
-200
9
Power pack & charging set
NiMH supply unit T4 with charger module und power pack
D-1
2286
-200
9
Power pack with connection cable (for worldwide use)
for up to 20 charger modules
Accessories
Dräger X-am® 5600 | 05
ST-
1436
0-20
08
Calibration cradle
ST-
9477
-200
7
Dräger X-am 125, external pump
External pump for hose length of up to 30 meters (98 feet). Makes itpossible to use the detector for pre-entry measurements into confinedspaces such as tanks, shafts, etc. The pump starts automatically whenthe detector is inserted. The change between diffusion and pumpoperation is quickly and easily possible without any need for additionaltools or steps.
Related Products
ST-
9466
-200
7
Dräger X-am® 5000
The Dräger X-am® 5000 belongs to a generation of gas detectors,developed especially for personal monitoring applications. This 1- to5-gas detector reliably measures combustible gases and vapors aswell as O2 and harmful concentrations of toxic gases, organic vapors,Odorant and Amine.
Related Products
06 | Dräger X-am® 5600
ST-
67-2
006
Dräger X-am® 7000
Dräger X-am® 7000 is the solution for the simultaneous andcontinuous measurement of up to five gases. It is the ideal companionin a variety of applications where the reliable detection of oxygen, toxicand combustible gases and vapors are necessary.
Technical Data
Dräger X-am® 5600 | 07
Dimensions (W × H × D) 47 × 130 × 44 mm; 1.85 × 5.12 × 1.73 inches
Weight 250 g; 8.8 oz.
Ambient conditions Temperature
Pressure
Humidity
- 20 to + 50 °C; - 4 to + 122 °F
700 to 1300 mbar; 20.7 to 38.4 inch Hg
10 to 95 % RH
Alarms Visual
Audible
Vibration
360°
Multi-tone > 90 dB at 30 cm; 1 ft.
Ingress Protection IP 67
Operating time ~ 9 h or rather ~ 10.5 h
Charging time < 4 hours
Data logger Can be read out via Infrared > 1000 hours
with 6 gases and a recording interval of 1 value per minute
Pump operation Maximum hose length 30 m; 98 ft.
ATEX I M1 Ex ia I Ma
II 1G Ex ia IIC T4/T3 Ga
Measurement performance certificate EN 50104 (2002) + A1 (2004) O2
EN 45544 CO, CO2 and H2S
EN 60079-29-1:2007 Methane, Propane,
Nonane
EN 50271:2001 Software and
documentation
IEC Ex ia l Ma
Ex ia llC T4/T3 Ga for MQG 01**
MED Marine Equipment Directive 96/98/EC
Approvals
CSA C US Div.1, Class I, Groups A,B,C,D T4/T3
A/Ex ia IIC T4/T3 /Ga
Ordering Information
Dräger X-am® 5600 83 21 050
Consisting of: basic instrument with an integrated data logger, support CD, manufacturer‘s and calibration certificates. A functional
instrument must include up to 4 sensors and a power supply unit.
Infrared-Sensors Measuring Range Resolution Response
time (t90)
Order code
0 – 100 % LEL 1 % LEL Ex: 15 sec.
0 – 100 Vol.-% Methane,
Propane, Ethylene
0.1 Vol.-% CH4 CO2: 31 sec.
DrägerSensor Dual IR
Ex/CO2 1)
0 – 5 Vol.-% CO2 0.01 Vol.-% CO2
68 11 960
0 – 100 % LEL 1 % LELDrägerSensor IR Ex1)
0 – 100 Vol.-% Methane,
Propane, Ethylene
0.1 Vol.-% CH4
15 sec. 68 12 180
DrägerSensor IR CO2 0 – 5 Vol.-% CO2 0.01 Vol.-% CO2 31 sec. 68 12 190
Ordering Information
08 | Dräger X-am® 5600
Electrochemical
Sensors
Measuring Range Resolution Response time (t90) Order Code
DrägerSensor XXS O2 0 – 25 Vol.-% 0.1 Vol.-% 10 sec. 68 10 881
DrägerSensor XXS CO 0 – 2,000 ppm 2 ppm 25 sec. 68 10 882
DrägerSensor XXS O2
100
0 - 100 Vol.-% 0.5 Vol.-% 5 sec. 68 12 385
DrägerSensor XXS CO
HC
0 – 10,000 ppm 5 ppm 25 sec. 68 12 010
DrägerSensor XXS CO/
H2 compensated
0 – 2,000 ppm CO 2 ppm 25 sec. 68 11 950
DrägerSensor XXS H2S 0 – 200 ppm 1 ppm 15 sec. 68 10 883
DrägerSensor XXS H2S
LC
0 – 100 ppm 0.1 ppm 15 sec. 68 11 525
DrägerSensor XXS H2S
HC
0 – 1,000 ppm 2 ppm 15 sec. 68 12 015
DrägerSensor XXS CO/
H2S
0 – 2,000 ppm CO / 0
– 200 ppm H2S
1 ppm H2S / 2 ppm CO 20 sec. 68 11 410
DrägerSensor XXS NO 0 – 200 ppm 0.1 ppm 10 sec. 68 11 545
DrägerSensor XXS NO2 0 – 50 ppm 0.1 ppm 15 sec. 68 10 884
DrägerSensor XXS SO2 0 – 100 ppm 0.1 ppm 15 sec. 68 10 885
DrägerSensor XXS PH3 0 – 20 ppm 0.01 ppm 10 sec. 68 10 886
DrägerSensor XXS PH3
HC
0 – 2,000 ppm 1 ppm 10 sec. 68 12 020
DrägerSensor XXS HCN 0 – 50 ppm 0.1 ppm 10 sec. (t50) 68 10 887
DrägerSensor XXS NH3 0 – 300 ppm 1 ppm 10 sec. (t50) 68 10 888
DrägerSensor XXS CO2 0 – 5 Vol.-% 0.1 Vol.-% 30 sec. (t50) 68 10 889
DrägerSensor XXS CI2 0 – 20 ppm 0.05 ppm 30 sec. 68 10 890
DrägerSensor XXS H2 0 – 2,000 ppm 5 ppm 10 sec. 68 12 370
DrägerSensor XXS H2
HC
0 – 4 Vol.-% 0.01 Vol.-% 20 sec. 68 12 025
DrägerSensor XXS OV 0 – 200 ppm 0.5 ppm 20 sec. (t50) 68 11 530
DrägerSensor XXS OV-A 0 – 200 ppm 1 ppm 40 sec. (t50) 68 11 535
DrägerSensor XXS
Amine
0 – 100 ppm 1 ppm 30 sec. 68 12 545
DrägerSensorXXS
Odorant
0 – 40 ppm 0.5 ppm 90 sec. 68 12 535
DrägerSensorXXS
COCl2
0 – 10 ppm 0.01ppm 20 sec. 68 12 005
DrägerSensor XXS
Ozone
0 – 10 ppm 0.01 ppm 10 sec. (t50) 68 11 540
Electrochemical
Sensors with 5 years
warranty
DrägerSensor XXS E
CO
0 – 2,000 ppm 2 ppm 15 sec. 68 12 212
DrägerSensor XXS E
H2S
0 – 200 ppm 1 ppm 15 sec. 68 12 213
DrägerSensor XXS E O2 0 – 25 Vol.-% 0.1 Vol.-% 10 sec. 68 12 2111) Special calibration for Ex sensors are available (standard setting: methane)
Ordering Information
Dräger X-am® 5600 | 09
Power supply units
NiMH power supply T4 83 18 704
NiMH power supply T4 high capacity 83 22 244
Power pack & charging set consisting of: rechargeable NiMH
power supply T4, charging module and a single charger (for
worldwide use)
83 18 785
Power pack & charging set HC consisting of: rechargeable NiMH
power supply HC T4, charging module and a single charger (for
worldwide use)
83 22 785
Battery holder ABT 0100 (without batteries) 83 22 237
Alkaline batteries T3 (2 pcs.) for battery holder 83 22 237 83 22 239
Alkaline batteries T4 (2 pcs.) for battery holder 83 22 237 83 22 240
Charging accessories
Charging module 83 18 639
Charging set basic, consisting of one charging module and a
single power supply (worldwide use)
83 20 333
Power supply with connection cable (worldwide use) for max. 20
charging modules
83 15 805
Single charger (worldwide use) for max. 5 charger modules 83 16 994
Single charger (worldwide use) for max. 2 charger modules 83 15 635
Car charging connection cabel 12 V / 24 V for a charging module 45 30 057
Vehicle charger mounting kit for one Dräger X-am® 1/2/5x00
charging module
83 18 779
Pump accessories
Dräger X-am® 1/2/5x00 external pump 83 19 400
Hand pump adapter 83 19 195
Confined space entry set, with an external pump and 3 m or 9 ft.
hose
83 19 399
Carrying case Dräger X-am® 1/2/5x00 external pump (without
pump)
83 19 385
Calibration accessories
Calibration cradle 83 18 752
Dräger X-dock 5300 for Dräger X-am® 1/2/5x00 83 21 880
Dräger Bump Test Station for Dräger X-am® 5600, not including
gas cylinder
83 19 131
Dräger Bump Test Station for Dräger X-am® 5600, complete with
one test gas cylinder 58L (gas and concentration variable)
83 19 130
Nonane Checker 83 20 080
Communication accessories Order code
Dräger GasVision 83 14 034
Dräger CC-Vision Freeware
USB DIRA with USB cable, communication adapter infrared to
USB
83 17 409
Ordering Information
10 | Dräger X-am® 5600
System components
Dräger X-zone® 5000 – 868 MHz, 12 Ah 83 20 740
Dräger X-zone® 5000 – 868 MHz, 24 Ah 83 20 741
Dräger X-zone® 5000 – 868 MHz, 12 Ah with pump 83 20 742
Dräger X-zone® 5000 – 868 MHz, 24 Ah with pump 83 20 743
In conjunction with the portable alarm amplifier Dräger X-zone® 5000 the units are combined to a new system; to monitor whole
working areas or to connect to external alarm contacts.
Notes
12 | Dräger X-am® 5600
CORPORATE HEADQUARTERS
Drägerwerk AG & Co. KGaAMoislinger Allee 53–5523558 Lübeck, Germanywww.draeger.com
Manufacturer:
Dräger Safety AG & Co. KGaARevalstraße 123560 Lübeck, Germany
REGION EUROPE CENTRALAND EUROPE NORTH
Dräger Safety AG & Co. KGaARevalstraße 123560 Lübeck, GermanyTel +49 451 882 0Fax +49 451 882 [email protected]
REGION EUROPE SOUTH
Dräger Safety France SAS25, rue Georges Besse92182 Antony CedexTel +33 1 46 11 56 00Fax +33 1 40 96 97 [email protected]
REGION MIDDLE EAST, AFRICA
Dräger Safety AG & Co. KGaABranch OfficeP.O. Box 505108Dubai, United Arab EmiratesTel +971 4 4294 600Fax +971 4 4294 [email protected]
REGION ASIA PACIFIC
Draeger Safety Asia Pte Ltd25 International Business Park#04-20/21 German CentreSingapore 609916Tel +65 6308 9400Fax +65 6308 [email protected]
REGION CENTRALAND SOUTH AMERICA
Dräger Panama S. de R.L.Complejo Business Park,V tower, 10th floorPanama CityTel +507 377 9100Fax +507 377 [email protected]
Locate your RegionalSales Representative at:www.draeger.com/contact
90
46
715
| 1
5-0
5-4
| C
om
mun
icat
ions
& S
ales
Mar
keti
ng |
PP
| L
E |
Pri
nted
in
Ger
man
y |
Chl
ori
ne-f
ree
– e
nvir
onm
enta
lly c
om
pat
ible
| S
ubje
ct t
o m
od
ific
atio
ns |
© 2
015
Drä
ger
wer
k A
G &
Co
. K
GaA