MR050A SERIES DEHYDRATOR
USER MANUAL
BulletinAE01B-A0532-001 Rev:A © 2008 CommScope, Inc. All rights reserved (06/08)
MR050A SERIES DEHYDRATOR USER MANUAL
2
SECTION 1 GeneralInformation 3 Introduction 3 Description 3 Operation 3 AlarmsOption 3 MultipleAlarmOption 4 Specifications 5
SECTION 2 Installation 6 UnpackingandInspection 6 ControlsandDisplays 6 PowerConnections 7 ACPower 7 DCPower 7 ConnectingLowPressureAlarmOutput 8 ConnectingDehydratortotheTransmissionLine 8 PurgingtheTransmissionLine 9
SECTION 3 Maintenance 9 Maintenance 9 PreventiveMaintenance 9 DesiccantReplacement 9 AnnualMaintenance 9 PartsReplacement 9 ServiceRestoration 10
SECTION 4 Troubleshooting 11 Problem/SolutionTable 11 SchematicDiagramMR050A-31015 13 AlarmSchematicDiagramwithAllOptionMR050A-31315 15 PneumaticDiagram 16
SECTION 5 ReplacementParts 17
SECTION 6 CustomerService 17 Introduction 17 InCaseofTrouble 17 InitialStepsbyAndrew 18 ReturnGoodsInstructions 18 RepairCenterProcess 18 LoanerUnits 18 Warranty 19
MR050A SERIES DEHYDRATOR USER MANUAL
3
1.1 Introduction
Thismanualcontainstheinformationyouneedtoinstall,operate,andmaintainyourMR050ASeriesDryLine®dehydrator.Pleasetakethetimetoreadthismanualbeforeattemptingtooperateorservicetheunit.
1.2 Description
MR050ASeriesdehydratorsprovidedryairforpressurizingsmall(upto280liters,or10cubicfeet,involume)antennaandtransmissionlinesystems.Thedehydratorsproduce-40ºC(-40ºF)dewpointdryairatanominalrateof1.4liters(0.05cubicfeet)perminuteuptoatotalof8495Iiters(300cubicfeet)onasingledesiccantcanister.
Eachdehydratorconsistsofanelectrically-drivenaircompressor,adesiccantcanister,anautomatictransmissionlinepressuresensingsystem,andalarmoutputshousedinarigidmetalchassis.Itisdesignedtomountdirectlytotherack,directlyonawall,orasafree-standingunit.Thefrontpanelfeaturesacontrolinterfacewithdisplayforalarmsandpressure.Foreasyserviceability,powerconnections,alarmoutputconnections,andthedesiccantcanisterareeasilyaccessiblefromthefrontoftheunit.
TheMR050Amaintainstransmissionlinepressuresbetween2.0and3.4kPa(0.3and0.5psig).Itisintendedforusewithhighperformancemicrowaveantennasandearthstationantennas.
1.3 Operation
MR050Aseriesdehydratorsincludeacompressor,colorindicatingdesiccant,highandlow-pressuresensors,andalow-pressurealarmsensor.
Whensystempressurefallstoapresetlowlimit,thelow-pressuresensoractivatesthecompressor.Airischanneledthroughadesiccantcanister,wheremoistureisadsorbed.Theairexitsthedryingcanisterat-40°C(-40°F)dewpoint.Itisthenchanneleddirectlytoaninternal4-portmanifold
. Whensystempressurereachesapresethigh
limit,thehigh-pressuresensorshutsoffthecompressor.Acheckvalvepreventssystemdryairfromretreatingbackthroughthecompressor.
Ifsystempressurefallssignificantlybelowthelow-pressuretriggerpoint,thelow-pressurealarmsensorwillactivateanalarmcontact.Thisalarmisanindicationofasignificantsystemleakoradehydratorfailure.
1.4 Alarms
TheMR050AoffersLowPressureandPowerFailalarmsasastandardfeature.Alarmconditionsareindicatedonthedisplay.Alarmsareoutputasacommonsummaryalarm,withaformCdrycontact.Thealarmissetforcontinuityonalarm.
MR050A SERIES DEHYDRATOR USER MANUAL
4
1.4.1 Multiple Alarm Option
ThisoptionalassemblyisdesignedtoprovidetheadditionalHighHumidityalarmtoAndrewDehydrators.AllalarmsareFormCdrycontactsandarefactorysetforcontinuityatalarm(mainspowerfailalarmopensatalarm).
Thisoptionalassemblywillalsoindicatediscretealarmsonthedisplay,andprovideindividualcontactsandconnectionsfordiscretealarms.
Theexternalalarmmonitoringsystem(suppliedbyothers)isconnectedtotheterminalstriplocatedonthefrontofthecabinet.Asmallslottedscrewdriverisnecessarytomaketheconnections.
Alarm Definitions:
Power Fail: Activatesopenwhenpowerisremovedfromthedehydrator.Thisincludesturningthepoweroffattheswitch.
High Humidity: Activateswhensystemordehydratoroutputhumidityriseabove7.5%relativehumidity.Atinitialinstallation,thisalarmwillcontinuetoalarmuntilthesystemhasbeenproperlypurged.
Excess Run: Factorysetruntimeissetinaccordancewiththenormalruntimeforthedehydratorapplication.Selectabletimesare30minutes,withthe10minuteasdefaultontheMR050A.
Low Pressure: Ifsystempressurefallsbelowthelow-pressuretriggerpoint,thelow-pressurealarmsensorwillactivateanalarmcontact.Thisalarmisanindicationofasignificantsystemleakoradehydratorfailure.
Alarm Factory setting Where To ResetSummary Normally TB4onControlAlarm Open(N.O.) Board
Multiple Alarms
Alarm Factory setting Where To Reset
LowPressure Normally JumperJP4on Open(N.O.) AlarmPCB A-B
Mains Normally JumperJP3on(PowerFail) Closed(N.C.) AlarmPCB B-C
ExcessRun Normally JumperJP1on Open(N.O.) AlarmPCB A-B
HighHumidity Normally JumperJP2on Open(N.O.) AlarmPCB A-B
Term. Function Wire Color
1 PowerFailCom Black
2 PowerFailAlarm Red
3 HumidityCom Green
4 HumidityAlarm Brown
5 ExcessRunCom Blue
6 ExcessRunAlarm White
7 LowPress.Com Gray
8 LowPress.Alarm Orange
Figure 1
Summary AlarmMulti Alarm
Changing Alarm Outputs:
MR050A SERIES DEHYDRATOR USER MANUAL
5
1.5 Specifications MR050A DehydratorCutOutPressure 35kPa(0.5PSIG)CutInPressure 2kPa(0.3PSIG)
Outputcapacity 85SLPH(total,approx.)1.4SLPM(3.0SCFH0.05SCFM)
OutputDewPoint, -40°C(-40°F)orbetter
OperatingTemperature 1°to+40°CRange (34°to+104°F)
LowPressureAlarm 1.4kPa(0.2PSIG)
ElectricalInput 24/48Vdc 115/230Vac,50/60Hz (withac-to-dcadapter)
PowerConsumption 11watts
OutputConnectors 3/8”polytube,compression
Dimensions 450mmWx132mmHx216mmD
(17.7”Wx5.2”Hx8.5”D)
Weight 7.26kg(16lbs)
Optional Alarms
HighHumidityAlarm 7.5%RH,factorysetpoint
PowerFailAlarm Lossofinputpower
ExcessRun 30minutes,factoryset
HighPressAlarm 5.5kPa(0.8PSIG)
Figure2
JP1Excess Run
JP2High Humidity
J P4Low Pressure
J3Alarm
Connection
J P3Power Fail
J5HUM Bypass
J4Humidity Sensor
J2Main Power
J1Alarm to Control
FUSE5 amp, 250V
MR050A SERIES DEHYDRATOR USER MANUAL
6
InstallationSection 2
Mode 1: Displayspressureandtotalrunhours.
Mode 2: Displayspressureandtotalrunhours,flashescurrentcondition.
Mode 3: DisplayslastONandlastOFFtimes.
ON/OFFSwitch TogglesunitconditionONandOFF.
ModeSwitch Togglesbetweendisplaymodes.
2.1 Unpacking and Inspection
OpenCarton
Removethetoppieceofclosed-cellfoampackaging.Carefullyremovetheinstallationaccessories,manual,anddehydrator.Checkthedehydratorforshippingdamagesuchasdentsorlooseparts.
2.2 ControlsandDisplays
Familiarizeyourselfwiththecontrolsanddisplayspriortoinstallingortestingthedehydrator.
ON/OFFSwitch
ModeSwitch
MR050A SERIES DEHYDRATOR USER MANUAL
7
2.3 InstallingtheDehydrator
2.3.1 19”RackMountingorsetonshelf
2.4 Power Connections
Confirmyourdehydratorelectricalinputmatchestheavailablepower.
24 Vdc/48 VdcMR050A-31015MR050A-31315
2.4.1 AC Power
ACunitscanbeconnectedintoastandard15Amppowerreceptacleofthepropervoltageviathepowersupply.Makesurethepowercircuitisproperlygrounded.Twopowercordsaresupplied,one115VACAmericanandone230VACInternational.
CAUTION:
Check the antenna and transmission line system pressure rating before connecting the dehydrator to the system.
TB1PIN 1 – DC – PIN 2 – 24 V JUMPERPIN 3 – DC MOTOR B PIN 4 – DC + PIN 5 – 24 V JUMPER PIN 6 – DC MOTOR
FUSE5 amp, 250V
Blue Tube Low Pressure
TB4Alarm Board
TB3Summary Alarm
Whitestripewire:+
MR050A SERIES DEHYDRATOR USER MANUAL
8
Note:
If the transmission lines have not been purged, continue with section 2.7. Otherwise proceed to section 3.
2.7 Purging the Transmission Line
Airinthetransmissionlinesystemmustbereplacedwithdryairtoensuresatisfactoryoperationofthetransmittedsignal.
1. Determinethetotalsystemvolume.
2. Dividethesystemvolumebytheflowrateofthedehydrator(3.0SCFH)todeterminethenumberofhoursneededforthepurgecycle.
3. Openthefarendofthetransmissionline.
4. Operatethedehydratorforthreepurgecycles.
Ifitisnotpossibletoopenthefarendofthetransmissionline,followthesesteps:
1. Connectthedehydratortothetransmissionlineandpressurizethesystem.Thesystempressureshouldreach0.5PSIG.
2. Wait15minuteswhiletheairabsorbsmoistureinthesystem,thendisconnectthedehydratorfromthetransmissionlineandallowtheairtovent.
3. Repeatsteps1and2twelvetimestopurgethesystem.
Test the Dehydrator
TurnthedehydratorONandchecktheoutputportontherearoftheunittomakesureairisflowing.
2.5 Connecting the Alarm Outputs
Toconnectthealarms,locatethealarmoutputterminalblockonthefrontoftheunit.
Optionalalarms(ifpurchased)willalsobelocatedonthisterminal(seesection1.4forterminalnumbers).
2.6 Connecting Dehydrator to the Transmission Line
Insertoneendofthe3/8”polytubefeedlinetubingintothecompressionfittingononeofthedehydratoroutputports.Tightensecurelywitha9/16”wrench.Becarefulnottoovertighten.Connecttheotherendofthepolytubetothetransmissionline.
Summary AlarmMulti Alarm
MR050A SERIES DEHYDRATOR USER MANUAL
9
MaintenanceSection 3 3.0 Maintenance
TheMR050ADehydratorrequiresrelativelylittlemaintenancetoensuresatisfactoryoperationoverlongperiodsoftime.Thissectionoutlinestherecommendedannualpreventivemaintenancefortheunitandthesuggestedoverhaulforevery6000hoursofcompressoroperation.
3.1 Preventive Maintenance
TheannualmaintenanceofaMR050Aconsistsofapreventativemaintenanceinspectionofthedehydrator.
Thesetaskscaneasilybeperformedinthefieldwiththeunitconnectedtothetransmissionlinesystem.
Inadditiontotheannualinspection,acompleteoverhaulisrecommendedevery6000hoursorsooneriflocalconditionswarrant.
3.2 Desiccant Replacement
Asthedesiccantbecomessaturatedovertime,itwillchangefrombluetopink.Whenthedesiccantisexhausted,therewillbeadegradationofperformance.Inordertoreplacethedesiccant,simplyturntheunitoff,disconnectthedesiccantcanisterfromthepneumaticlines,andreplacetheentirecanister.
3.3 Annual Inspection
Inspectionincludescheckingforlooseordamagedhoses,fittings,andelectricalconnections.Removethedesiccantcanisterandverifythattherearenoleaksinthepneumaticlines.
Warning:
Electrical Hazard! Unplug power cord before servicing unit.
Check the electrical connections.
CheckthescrewatthepowerinputconnectortoensurethattheACpowercordissecurelyterminated.Checkthescrew-inalarmterminalstoensurethatallwireconnectionsaretight.
Alooseordamagedconnectionmayresultinerraticoperationandunnecessarydowntime.Refertothetroubleshootingsectionifanelectricalproblemisencountered.
Check the ground wire.
Checkthatanelectricalsafetygroundisinstalledonthestudontherearofthedehydrator.Thisconnectionpointisadjacenttothepowerinputconnector.(Itisintendedtobecustomerinstalledinthefield.)
Checkthehourmeteronthefrontpaneltodeterminethedutycycleofthedehydrator.
Ifthedehydratorhasbeenrunningformorethan10%ofitsinstalledtime,checkthesystemsforleaks.
3.4 Parts Replacement
WhentheMR050Adehydratorunitisinneedofservice,themaincomponentsaresimplyreplaced.Thecompressor,desiccantcanister,andcontrolmoduleareallmeanttobereplaceableparts.ThepartscanbepurchasedfromAndrewCorporationforfieldreplacement,ortheunitcanbesenttotherepaircenterforcomponentreplacement.
MR050A SERIES DEHYDRATOR USER MANUAL
10
Unit Shutdown and Removal
InordertoperformanoverhaulontheMR050A,theunitmustbeturnedoffandremovedfromservice.Asthisisbeingdone,thelowpressurealarmmayactivatethroughareportingalarmsystem.Personnelmonitoringsuchanalarmshouldbenotifiedinadvancesothattheyareawareofthefactthatserviceisbeingperformed.Itisalsonecessarytodisconnectthedehydratordryairoutputfromthewaveguidesystemduringtheoverhaul.
Removethechassistopandfrontpanelsforoverhaul.
1. Unplugtheunitfromthepowersupply.
2 Followtheinstructionsincludedinthecompressorreplacementkit.Whenthereplacementiscomplete,reinstall.
3.5 Service Restoration
RECOMMENDATION:
Ifthedehydratoroverhaulprocesshastakenmorethanafewhours,itisrecommendedthattheunitberunforonehourintotheroom,topurgethemembranedryerandtankofanyacquiredmoisture,beforereconnectingtothetransmissionlinesystem.
MR050A SERIES DEHYDRATOR USER MANUAL
11
TroubleshootingSection 4 Ifyouexperiencedifficultywithyourdehydrator,usethetroubleshootingproceduresdescribedbelow.
Caution: Electrical troubleshooting requires access to potentially dangerous voltages and should only be performed by a licensed electrician
Problem/Condition Solution
Dehydratordisplaydoesnotlight,unitdoesnotrun.
Low-pressurealarmactivated.
CompressordoesnotturnOFF.
Ifthedisplaylightfailstolight,makesuretheunitispluggedinandpoweroutletisoperating.
Ifyoustillhavenolight,unplugtheunit,removetheunitcoverandcheckforlooseconnections.Refertothewiringdiagramforproperconnections.
ChecktoassurethatthefuseisOK.ChecktoassurethatproperACvoltageisbeingsuppliedtotheinput.
Plugtheunitoutputwithfingerandobservepressuregauge.Thepressuregaugelineshouldreadapproximately0.5psiandthealarmshouldclear.Ifalarmdoesnotclear,removecoverandverifytubingandwiringconnectionsaresecure.
Ifthepressuredoesnotremainconstantafterpluggingtheoutput,applyleakdetectortoisolatetheleakinthedehydrator(exercisecarewhenapplyingsolutionnottowetwiringorelectronics).
Withdehydratorisolatedfromtransmissionline,observepressureintransmissionline.Ifpressuredrops,usealeakdetectorsolutiontolocateleaksinthetransmissionline.Repairleaksifpossible.
IftheproblempersistscontactAndrewCustomerService.Checkthedisplayonthecontroller.ToggletheON/OFFswitch(leftofthedisplay).Checkinputpowerpolarityandvoltageperwiringdiagram.
MR050A SERIES DEHYDRATOR USER MANUAL
13
MR
050A
-310
15W
iring
Dia
gramTB
4
TB1
CO
MPR
ESSO
R
POW
ER
STR
IP
OR
AN
GE
GR
AY
TB3
U9
+ W
HIT
E
- BLA
CK
BLA
CK
BLA
CK
WH
ITE
BLA
CK
WH
ITE
FUSE
5 am
p, 2
50 V
PIN
1 IS
B
LAN
K.
SUM
MA
RYA
LAR
M
MR050A SERIES DEHYDRATOR USER MANUAL
15
MR
050A
-313
15W
iring
Dia
gram
HU
MID
ITY
SEN
SOR
FUSE
5 a
mp,
250
V
J5
J1
J2
TB4
TB1
CO
MPR
ESSO
R
J4
POW
ER F
AIL
, B
LAC
K
POW
ER F
AIL
ALA
RM
, RED
HU
MID
ITY
CO
M, G
REE
N
HU
MID
ITY,
BR
OW
N
EXC
ESS
RU
N C
OM
, BLU
E
EXC
ESS
RU
N A
LAR
M, W
HIT
E
LOW
PR
ESS
CO
M, G
REY
LOW
PR
ESS
ALA
RM
, OR
AN
GE
TB3
U9
BLA
CK
BLA
NK
GR
EEN
RED
BLA
CK
RED
GR
EEN
+ W
HIT
E
- B
LAC
KB
LAC
K
BLA
CKW
HIT
E
BLA
CK
WH
ITE
FUSE
5 am
p, 2
50 V
POW
ER
STR
IP
FULL
ALA
RM
MR050A SERIES DEHYDRATOR USER MANUAL
16
Des
icca
ntC
anis
ter
1/4"
Hos
e15
" Lo
ng
1/4"
Hos
e7.
5" L
ong
1/4"
Hos
e5"
Lon
g
-310
15 O
nly
1/4"
Hos
e7.
5" L
ong
-313
15 O
nly
1/4"
Hos
e11
.5"
Hos
e
Com
pres
sor
-313
15 O
nly
1/4"
Hos
e8"
Hos
e
-313
15 O
nly
Hum
idity
Sen
sor
Sub
-ass
embl
y
1/4"
Hos
e5"
Lon
g
Con
trol
Mod
ule
Man
ifold
Sub-
asse
mbl
y
Pneu
mat
ic D
iagr
am
MR050A SERIES DEHYDRATOR USER MANUAL
17
Replacement PartsSection 5
Customer ServiceSection 6
ThefollowingisalistofthereplacementkitsfortheMR050ASeriesdehydrators:
6.0 Introduction
Andrewprovidesin-warrantyandout-of-warrantyrepairsaswellasdehydratorandcompressoroverhaulsfromseveralRepairCenters.CoordinationoftheseservicesisprovidedthroughthenearestSalesOfficeorCustomerServiceCenter.TheCenterisalsopreparedtohelpyouwiththefollowing:TechnicalAssistanceTroubleshootingRepairsLoanerUnitsSparePartsInstallationMaterialsSystemAccessories.
6.1 In Case of Trouble
Thefirststepyoushouldtakeiftroubledevelopsusingadehydratoristoreadtheoperatorsmanualandfollowthetroubleisolatingproceduresgiveninit.
Ifthestepsinthemanualdonotidentifyandremedytheproblem,thencontactanAndrewCustomerServiceCenterfor24-hourtelephoneassistance.RecordtheModelNumber(e.g.MR050A)andSerialNumberfromtheproductlabel,asyouwillbeaskedforthesewhenyoucall.Twomainlocationsarecurrentlyavailabletohelp:
inNorthAmerica---1-800-255-1479
inEurope---+441592782612
anyLocation(toUSA)(708)349-3300
IfyoufinditeasiertodescribeyourtroublesbyFax,thenthefollowingnumbersarealsoavailable:
inNorthAmerica---1-800-349-5444(Faxonly)
inEurope---+441592782380(Faxonly)
anyLocation(toUSA)(708)349-5410(Faxonly)
Andrew Corporation 0500W.153rdStreet OrlandPark,IL60462USA
DesiccantKitMR050A-KIT-DSCNT
CompressorKitMR050A-KIT-CPRSR
ControllerKitMR050A-KIT-CNTLR
Check website for latest updates to the manaul and parts lists.
MR050A SERIES DEHYDRATOR USER MANUAL
18
6.2 Initial Steps by Andrew
Whenyourcallorfaxcommunicationisreceived,theAndrewstaffwillworkwithyoutopinpointthepossiblecauseoftrouble.Ifthepressurizationequipmentissuspect,theywill:
• askforyourunitModelNumberandSerialNumber
• checkthewarrantystatusoftheunit
• advisetheavailabilityofaloanerunitprovideofthecostforinspectionandrepairs,iftheunitisout-of-warranty
• faxaReturnGoodsAuthorizationSheettoyou.
6.3 Return Goods Instructions
AfteryouhavecontactedAndrewandreceivedaReturnGoodsAuthorizationNumber(RGN),youwillneedtotakethefollowingstepstosendthefaultyunittoaRepairCenter:
• makeacopyoftheReturnGoodsAuthorizationSheetthatwasfaxedtoyou
• writeabriefdescriptionofthetroubleyouareencounteringandattachthistothecopyofthesheet
• packtheunit(withatleast4-inchesofprotectivepackagingonallsides)
• enclosetheauthorizationsheetandtroubledescriptionwithinthebox
• encloseapurchaseorderorothermethodofpaymentfornonwarrantyrepairs.
• marktheoutsideoftheboxwiththeRGN
• returntheboxtotheRepairCenteraddresslistedontheauthorizationsheet. Ifyouhavesavedtheoriginalpackagingthatcamewiththeunit,useittoreturnthedehydratorforrepair.Ifaloanerunit(ofthesametype)wassuppliedbyAndrew,usetheloanerunitboxtoreturntheoriginaldehydrator.
6.4 Repair Center Process
TheAndrewDehydratorRepairCenterwillreceiveyourunitandinspectitforanytransportdamage.TheunitwillthenbeanalyzedfortroublesusingthedescriptionyouhavesuppliedandthespecializedexperiencetheRepairCenterstaffhavewithdehydrators.
Iftheunitisin-warranty,repairsaremadeatnochargeandtheunitwillbereturnedtoyoubythesamemodeoftransportasitwasreceived.
Iftheunitisin-warranty,butnoproblemsarefound,theunitwillbethoroughlytestedbeforebeingreturnedtoyou.Anominalinspectionfeewillbechargedforthisservice.
Ifyourunitisout-of-warranty,itwillbeinspectedandrepairedforthequotedfee.
6.5 Loaner Units
TheAndrewdehydratorRepairCentersstockalimitednumberof“loaner”dehydratorunitsofbothcurrentanddiscontinuedproducts.Theseunits,whilenotnew,arestillinexcellentworkingorder.
Loanersareavailableonafirst-comefirst-servedbasis.TheyareissuedinconjunctionwiththeoriginalRGNandareinvoicedatanominalprice.YouwillneedtorequestasecondRGNtoreturntheloanerunit.AcreditmemoisissuedbytheRepairCenterwhenaloanerisreturned
MR050A SERIES DEHYDRATOR USER MANUAL
19
®
Andrew Corporation
Small and Medium Capacity Dehydrator and Line Monitor System
Three Year Warranty Seller warrants that any Andrew MT050, MT/XT300, MT/XT500, MR050, PMT200 and ODPMT200 series number type DryLine® Dehydrator is transferred rightfully and with good title; that it is free from any lawful security interest or other lien or encumbrance unknown to Buyer; and that for a period of thirty-six (36) months from the date of shipment or 3000 hours of actual run time, whichever shall occur first, such equipment will be free from defects in material and workmanship which arise under proper and normal use and service. Buyer's exclusive remedy hereunder is limited to Seller's correction (either at its plant or at such other place as may be agreed upon between Seller and Buyer) of any such defects by repair or replacement (with either a new unit or a factory reconditioned unit) at no cost to Buyer; provided that the cost of any transportation in connection with the return of the equipment for the purpose of repair or replacement shall be borne by Buyer. The provisions of this warranty shall be applicable with respect to any equipment which Seller repairs or replaces pursuant to it. Expressly excluded from the terms of this warranty are defects caused by: (i) faulty installation, (ii) lack of proper inspection or maintenance, (iii) and usage not in accordance with published ratings, specifications, or instructions. The provisions of this warranty shall be applicable with respect to any equipment Seller repairs or replaces pursuant to it.
SELLER MAKES NO WARRANTY, EXPRESS OR IMPLIED, OTHER THAN AS SPECIFICALLY STATED ABOVE. EXPRESSLY EXCLUDED ARE ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR PURPOSE. THE FOREGOING SHALL CONSTITUTE ALL OF SELLER'S LIABILITY (EXCEPT AS TO PATENT INFRINGEMENT) WITH RESPECT TO THE EQUIPMENT. IN NO EVENT SHALL SELLER BE LIABLE FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES, INSTALLATION COSTS, LOST REVENUE OR PROFITS, OR ANY OTHER COSTS OF ANY NATURE AS A RESULT OF THE USE OF THE EQUIPMENT MANUFACTURED BY SELLER, WHETHER USED IN ACCORDANCE WITH INSTRUCTIONS OR NOT. UNDER NO CIRCUMSTANCES SHALL SELLER'S LIABILITY TO BUYER EXCEED THE ACTUAL SALES PRICE OF THE EQUIPMENT PROVIDED HEREUNDER. No representative is authorized to assume for Seller any other liability in connection with the equipment.
Rev 2 0706