Trane Product Catalog Furnace Models - Surplus City Liquidators

40
FU – 1 Effective date: January 1, 2008 © Trane 2007 Furnace Configuration TU = Upflow / Horizontal TD = Downflow / Horizontal Type E = 80% Induced Draft Standard D = 80% Induced Draft Premium C = 90% Condensing Standard X = 90% Condensing Premium H = 95% Condensing Premium Number of Heating Stages 1 = Single Stage 2 = Two Stage 3 = Three Stage Cabinet Width A = 14.5" Cabinet Width B = 17.5" Cabinet Width C = 21.0" Cabinet Width D = 24.5" Cabinet Width Heating Input 080 = 80,000 BTUH Major Design Change Voltage 9 = 115 Volts / 60 Hertz / Natural Gas A = 115 Volts / 50 Hertz / Natural Gas C = 115 Volts / Natural Gas with Communicating System Control F = 115 Volts / Natural Gas with Integrated Electronic Filter D = 115 Volts / Natural Gas with Communicating System Control and Integrated Electronic Filter Airflow Capacity for Cooling 36 = 3 Ton Standard PSC Motor H3 = 3 Ton High Efficiency Motor V3 = 3 Ton Variable Speed Motor Draft Inducer Speeds 1 = Single Speed 2 = Two Speed V = Variable Speed Minor Design Change Service Digit - Not Orderable T U X 1 B 0 8 0 A 9 3 6 1 A A Gas Furnace Nomenclature

Transcript of Trane Product Catalog Furnace Models - Surplus City Liquidators

FU – 1 Effective date: January 1, 2008© Trane 2007

Furnace ConfigurationTU = Upflow / Horizontal TD = Downflow / Horizontal

TypeE = 80% Induced Draft StandardD = 80% Induced Draft PremiumC = 90% Condensing StandardX = 90% Condensing PremiumH = 95% Condensing Premium

Number of Heating Stages1 = Single Stage2 = Two Stage3 = Three Stage

Cabinet WidthA = 14.5" Cabinet WidthB = 17.5" Cabinet WidthC = 21.0" Cabinet WidthD = 24.5" Cabinet Width

Heating Input080 = 80,000 BTUH

Major Design Change

Voltage9 = 115 Volts / 60 Hertz / Natural GasA = 115 Volts / 50 Hertz / Natural GasC = 115 Volts / Natural Gas with Communicating System ControlF = 115 Volts / Natural Gas with Integrated Electronic FilterD = 115 Volts / Natural Gas with Communicating System Control and Integrated Electronic Filter Airflow Capacity for Cooling36 = 3 Ton Standard PSC MotorH3 = 3 Ton High Efficiency MotorV3 = 3 Ton Variable Speed Motor

Draft Inducer Speeds1 = Single Speed2 = Two SpeedV = Variable Speed

Minor Design Change

Service Digit - Not Orderable

T U X 1 B 0 8 0 A 9 3 6 1 A A

Gas Furnace Nomenclature

FU – 2 Effective date: January 1, 2008© Trane 2007

T U Y 0 8 0 R 9 V 3 V 0

Furnace ConfigurationTD = Downflow / HorizontalTU = Upflow / Horizontal

TypeC = CondensingD = Induced DraftE = Electronic IgnitionX = Direct Vent CondensingY = Direct Vent Condensing Variable Speed

Heating Input MBTUH080 = 80,000 BTUH

Major Design ChangeC = Single Stage R = Two StageAll Other = Standard System

Power Supply & Fuel115 VoltNatural Gas

Airflow Capacity for CoolingExample: 36 = 3 Tons 400 CFM/Ton 400 x 3 Tons = 1200 CFMV3 = 1 1/2 - 3 Tons, Variable Speed MotorV4 = 2 - 4 Tons, Variable Speed MotorV5 = 3 - 5 Tons, Variable Speed Motor Minor Design ChangeV = Variable Speed Inducer

Service Digit - Not Orderable

Gas Furnace Nomenclature

FU – 3 Effective date: January 1, 2008© Trane 2007

TUE1A040 — D140A XB80 TDE1A060 — D120A Gas Furnace Upflow/Horizontal Single Stage Downflow/HorizontalSpecifications: Upflow/Horizontal Induced Draft Airflow Nominal Uncrated Model In Tons Cap-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Htg Output AFUE Size H W D Plant Weight

TUE1A040A9241A 2 31,000 80.0 4" 40 14.5 28 TR 119TUE1A060A9241A 2 47,000 80.0 4" 40 14.5 28 TR 124 TUE1A060A9361A 3 47,000 80.0 4" 40 14.5 28 TR 127TUE1B060A9361A 3 47,000 80.0 4" 40 17.5 28 TR 132 TUE1B080A9361A 3 63,000 80.0 4" 40 17.5 28 TR 142 TUE1B080A9481A 4 64,000 80.0 4" 40 17.5 28 TR 142 TUE1B100A9361A 3 79,000 80.0 4" 40 17.5 28 TR 151TUE1C100A9481A 4 79,000 80.0 4" 40 21.0 28 TR 162 TUE1C100A9601A 5 79,000 80.0 4" 40 21.0 28 TR 162TUE1D120A9601A 5 96,000 80.0 4" 40 24.5 28 TR 186TUE1D140A9601A 5 111,000 80.0 4" 40 24.5 28 TR 193

Specifications: Downflow/Horizontal Induced Draft Airflow Nominal Uncrated Model In Tons Cap-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Htg Output AFUE Size H W D Plant Weight

TDE1A060A9361A 3 48,000 80.0 4" 40 14.5 28.0 TR 129 TDE1B060A9361A 3 48,000 80.0 4" 40 17.5 28.0 TR 134TDE1B080A9451A 4 64,000 80.0 4" 40 17.5 28.0 TR 146 TDE1B100A9451A 4 80,000 80.0 4" 40 17.5 28.0 TR 156 TDE1C100A9601A 5 81,000 80.0 4" 40 21.0 28.0 TR 167 TDE1D120A9601A 5 96,000 80.0 4" 40 24.5 28.0 TR 189 *Isolated Combustion System.

Accessories:Model Mfg. ShippingNumber Description Used WIth Plant Weight

Extended Warranties (See Extended Warranty Section)TCONT200AN11AA Electronic, 1Htg/1Clg (Non Prog.) All Cooling/(Gas or Elec) TY 1 BAYLPKT210B Propane Conversion Kit All TUE1/TDE1 Furnaces TR 1BAYLPSS210B1 Propane Conversion Kit All TUE1/TDE1 Furnaces TR 1 BAYFLTR206 Filter Access Door Kit All TDE1 Furnaces TR 2BAYRACK960A2 Filter Rack Kit All TUE1 FurnacesBAYFLTR317 Filter Accessory Kit Upflow 14.5" & 17.5" Furnaces TR 2BAYFLTR321 Cleanable Filter Upflow 21" Furnaces TR 2BAYFLTR324 Cleanable Filter Upflow 24.5" Furnaces TR 2BAYBASE205 Downflow Subbase All TDE1 Furnaces TR 8BAYHALT248 High Alt. Pressure Switch Kit All TUE1/TDE1 Furnaces TR 21 With stainless steel burners.2 Internal filter rack for side or bottom return air. Includes 17.5" cleanable filter.

Features:•Upflow/Horizontal&Downflow/Horizontal•Powersupply115/1/60•Multi-portIn-shotburners•SiliconCarbidehotsurfaceigniterwith

adaptive heat up•Heavygauge,wrap-aroundsteelcabinet•Completefrontserviceaccess•Heavygaugealuminizedsteelheat

exchanger

•Alternatebottom/left/rightreturnair•Slideoutblowerassembly•Directdrive,4-speedmotors•Blowerdoorsafetyswitch•OptionalL.P.conversionkit•Commonventcapability•Selectablecoolingfanoffdelayoption

eliminates need for BAY24X045 time delay relay

•Innerblowerdoorpanelondownflowmodels•3-wayventoptionondownflowmodels(top,

right, or left)•Non-prorated 20-year heat exchanger

limited warranty (Residential use)•Optional extended warranties•5-year limited parts warranty

FU – 4 Effective date: January 1, 2008© Trane 2007

TUD1A040 — D140A XR80 Upflow/Horizontal Gas Furnace Single Stage

Specifications: Upflow/Horizontal Induced Draft Airflow Nominal Uncrated Model In Tons Cap-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Htg Output AFUE Size H W D Plant Weight

TUD1A040A9241A 2 32,000 80.0 4" 40 14.5 28 TR 119 TUD1A040A9301A 2.5 32,000 80.0 4" 40 14.5 28 TR 122 TUD1A060A9241A 2 47,000 80.0 4" 40 14.5 28 TR 124 TUD1A060A9361A 3 47,000 80.0 4" 40 14.5 28 TR 127TUD1B060A9361A 3 47,000 80.0 4" 40 17.5 28 TR 132 TUD1B080A9241A 2 64,000 80.0 4" 40 17.5 28 TR 139 TUD1B080A9361A 3 63,000 80.0 4" 40 17.5 28 TR 142 TUD1B080A9481A 4 64,000 80.0 4" 40 17.5 28 TR 142TUD1C080A9601A 5 64,000 80.0 4" 40 21.0 28 TR 154 TUD1B100A9361A 3 79,000 80.0 4" 40 17.5 28 TR 151 TUD1B100A9451A 4 80,000 80.0 4" 40 17.5 28 TR 153 TUD1C100A9481A 4 79,000 80.0 4" 40 21.0 28 TR 162 TUD1C100A9601A 5 79,000 80.0 4" 40 21.0 28 TR 162TUD1D100A9721A 6 80,000 80.0 4" 40 24.5 28 TR 175 TUD1C120A9541A 5 96,000 80.0 4" 40 21.0 28 TR 176 TUD1D120A9601A 5 96,000 80.0 4" 40 24.5 28 TR 186 TUD1D140A9601A 5 111,000 80.0 4" 40 24.5 28 TR 193 *Isolated Combustion System.

Accessories:Model Mfg. ShippingNumber Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit All TUD1 Furnaces TR 1BAYLPSS210B1 Propane Conversion Kit All TUD1 Furnaces TR 1 BAYHALT248 High Altitude Pressure Switch Kit All TUD1 Furnaces TR 2BAYVENT800B Masonry Chimney Vent Kit All TUD1A060,080,100,120,140 TR 2BAYRACK960A2 Filter Rack Kit-Internal All TUD1 Furnaces TR 5BAYFLTR200 Side Filter Rack Kit-External All TUD1 Furnaces TR 5BAYFLTR317 Cleanable filter Upflow 14.5"/17.5" Furnaces TR 2BAYFLTR321 Cleanable filter Upflow 21" Furnaces TR 2BAYFLTR324 Cleanable filter Upflow 24.5" Furnaces TR 21 With stainless steel burners.2 Internal filter rack for side or bottom return air. Includes 17.5" cleanable filter.

•Blowerdoorsafetyswitch•Singlewiretwinning•Perfectfitdoorlatches• Insulatedblowerdoor•Gasketedblowerdoor•Twotonecolor•Quietslowopeninggasvalve•OptionalL.P.conversionkit•Commonventcapability•Selectablecoolingfanoffdelayeliminates

need for BAY24X045 time delay relay• Insulatedblowercompartment

•Accessoryhook-upcapability•Left/rightgasconnection•24voltfuse•Manualresetflamerolloutswitches•Non-prorated 20-year heat exchanger

limited warranty (Residential use)•5-year limited parts warranty•Optional extended warranties

Features:•Powersupply115/1/60•Multi-portIn-shotburners• Integratedsolidstatecontrolwith

self-diagnostics•SiliconNitridehotsurfaceigniterwith

adaptive heat up•Heavygauge,wrap-aroundsteelcabinet•Completefrontserviceaccess•Heavygaugealuminizedsteelheat

exchanger•Alternatebottom/left/rightreturnair•Slideoutblowerassembly•Directdrive,4-speedmotors

Ref

: 9/2

2/08

9:0

0 am

Effective date: August 7, 2008

FU – 5 Effective date: January 1, 2008© Trane 2007

TDD1A040 — D140A XR80 Downflow/Horizontal Gas Furnace Single Stage

Specifications: Downflow/Horizontal Induced Draft Airflow Nominal Uncrated Model In Tons Cap-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Htg Output AFUE Size H W D Plant Weight

TDD1A040A9241A 2 31,000 78.0 4" 40 14.5 28 TR 119 TDD1A060A9241A 2 48,000 80.0 4" 40 14.5 28 TR 129 TDD1A060A9361A 3 48,000 80.0 4" 40 14.5 28 TR 129TDD1B060A9361A 3 48,000 80.0 4" 40 17.5 28 TR 134 TDD1B080A9361A 3 64,000 80.0 4" 40 17.5 28 TR 146 TDD1B080A9451A 4 64,000 80.0 4" 40 17.5 28 TR 146 TDD1B100A9451A 4 80,000 80.0 4" 40 17.5 28 TR 156 TDD1C100A9481A 4 80,000 80.0 4" 40 21.0 28 TR 166 TDD1C100A9541A 5 81,000 80.0 4" 40 21.0 28 TR 167 TDD1C120A9541A 5 96,000 80.0 4" 40 21.0 28 TR 177TDD1D120A9601A 5 96,000 80.0 4" 40 24.5 28 TR 189 TDD1D140A9601A 5 113,000 80.0 4" 40 24.5 28 TR 196 *Isolated Combustion System.

Accessories:Model Mfg. ShippingNumber Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit All TDD1 Furnaces TR 1BAYLPSS210B1 Propane Conversion Kit All TDD1 Furnaces TR 1 BAYFLTR206 Filter Access Door Kit All TDD1 Furnaces TR 2BAYBASE205 Downflow Subbase All TDD1 Furnaces TR 8 BAYHALT248 High Altitude Pressure Switch Kit All TDD1 Furnaces TR 2BAYFLTR206 Filter Access Door Kit All TDD1 Furnaces TR 21 With stainless steel burners.

•Slideoutblowerassembly•Directdrive,4-speedmotors•Blowerdoorsafetyswitch•OptionalL.P.conversionkit•Commonvent•Selectablecoolingfanoffdelayeliminates

need for BAY24X045 time delay relay•Quietslowopeninggasvalve•Singlewiretwinning• Insulatedblowerdoor• Insulatedblowercompartment

Features:•Powersupply115/1/60•Multi-portIn-shotburners• Integratedsolidstatecontrolwith

self-diagnostics•SiliconNitridehotsurfaceigniterwith

adaptive heat up•Heavygauge,wrap-aroundsteelcabinet•Completefrontserviceaccess•Heavygaugealuminizedsteelheat

exchanger

•Accessoryhook-upcapability•Rightandlefthandsideknockoutforventing•24voltfuse•Manualresetflamerolloutswitches•Twotonecolor•Non-prorated 20-year heat exchanger

limited warranty (Residential use)•5-year limited parts warranty•Optional extended warranties

FU – 6 Effective date: January 1, 2008© Trane 2007

Features:•VariablespeedindoorblowerwithConstantTorqueECMblowermotor•Powersupply115/1/60•Multi-portIn-shotburners• Integratedsolidstatecontrolwithself-diagnostics•SiliconNitridehotsurfaceigniterwithadaptiveheatup•Heavygauge,wrap-aroundsteelcabinet•Completefrontserviceaccess•Heavygaugealuminizedsteelheatexchanger•Alternatebottom/left/rightreturnair

TUD1 - H XT80 Upflow/Horizontal Gas Furnace Single Stage High Efficiency MotorSpecifications: Upflow/Horizontal Induced Draft Airflow Nominal Uncrated Model In Tons Cap-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Htg Output AFUE Size H W D Plant Weight

TUD1A040A9H21B 2 32,000 80.0 4" 40 14.5 28 TR 119TUD1B060A9H31B 3 47,000 80.0 4" 40 17.5 28 TR 127TUD1B080A9H31B 3 63,000 80.0 4" 40 17.5 28 TR 142TUD1C080A9H41B 4 64,000 80.0 4" 40 21.0 28 TR 142TUD1B100A9H31B 3 79,000 80.0 4" 40 17.5 28 TR 151TUD1C100A9H51B 5 79,000 80.0 4" 40 21.0 28 TR 162TUD1D120A9H51B 5 96,000 80.0 4" 40 24.5 28 TR 186TUD1D140A9H51B 5 111,000 80.0 4" 40 24.5 28 TR 193*IsolatedCombustionSystem.

Accessories:Model Mfg. ShippingNumber Description Used With Plant Weight

ExtendedWarranties (1yr-5yr-10yr-15yr–SeeExtendedWarrantySection)Controls (SeeControlSection)BAYLPKT210B PropaneConversionKit AllTUD1-HFurnaces TR 1BAYLPSS210B1 PropaneConversionKit AllTUD1-HFurnaces TR 1BAYHALT248 HighAltitudePressureSwitchKit AllTUD1-HFurnaces TR 2BAYVENT800B MasonryChimneyVentKit AllTUD1A060,080,100,120,140 TR 2BAYRACK960A2 FilterRackKit-Internal AllTUD1-HFurnaces TR 5BAYFLTR317 Cleanablefilter Upflow14.5"/17.5"Furnaces TR 2BAYFLTR321 Cleanablefilter Upflow21"Furnaces TR 2BAYFLTR324 Cleanablefilter Upflow24.5"Furnaces TR 21Withstainlesssteelburners.2 Internalfilterrackforsideorbottomreturnair.Includes17.5"cleanablefilter.

•Slideoutblowerassembly•Blowerdoorsafetyswitch•Singlewiretwinning•Perfectfitdoorlatches• Insulatedblowerdoor•Gasketedblowerdoor• Internalfilterrack•Standardfiltersizes•Cleanablehighvelocityfilters•Twotonecolor•Quietslowopeninggasvalve•OptionalL.P.conversionkit

•Commonventcapability•SelectablecoolingfanoffdelayeliminatesneedforBAY24X045timedelayrelay• Insulatedblowercompartment•Accessoryhook-upcapability•Left/rightgasconnection•24voltfuse•Manualresetflamerolloutswitches•Non-prorated 20-year heat exchanger

limited warranty (Residential use)•5-year limited parts warranty•Optional extended warranties

Ref:1/12/0912:24pm

Effectivedate:January2,2009

FU – 7 Effective date: January 1, 2008© Trane 2007

TDD1 - H XT80 Downflow/Horizontal Gas Furnace Single Stage High Efficiency Motor Specifications: Downflow/Horizontal Induced Draft Airflow Nominal Uncrated Model In Tons Cap-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Htg Output AFUE Size H W D Plant Weight

TDD1B060A9H31B 3 48,000 80.0 4" 40 17.5 28 TR 12TDD1B080A9H31B 3 64,000 80.0 4" 40 17.5 28 TR 146TDD1C100A9H51B 5 81,000 80.0 4" 40 21.0 28 TR 167TDD1D120A9H51B 5 96,000 80.0 4" 40 24.5 28 TR 189*IsolatedCombustionSystem

Accessories:Model Mfg. ShippingNumber Description Used With Plant Weight

ExtendedWarranties (SeeExtendedWarrantySection)Controls (SeeControlSection)BAYLPKT210B PropaneConversionKit AllTDD1-HFurnaces TR 1BAYLPSS210B1 PropaneConversionKit AllTDD1-HFurnaces TR 1BAYFLTR206 FilterAccessDoorKit AllTDD1-HFurnaces TR 2BAYBASE205 DownflowSubbase AllTDD1-HFurnaces TR 8BAYHALT248 HighAltitudePressureSwitchKit AllTDD1-HFurnaces TR 2BAYFLTR206 FilterAccessDoorKit AllTDD1-HFurnaces TR 21Withstainlesssteelburners.

•Cleanablehighvelocityfilters•Blowerdoorsafetyswitch•OptionalL.P.conversionkit•Commonvent•SelectablecoolingfanoffdelayeliminatesneedforBAY24X045timedelayrelay•Quietslowopeninggasvalve•Singlewiretwinning• Insulatedblowerdoor• Insulatedblowercompartment•Accessoryhook-upcapability

Features:•Powersupply115/1/60•Multi-portIn-shotburners• Integratedsolidstatecontrolwithself-diagnostics•SiliconNitridehotsurfaceigniterwithadaptiveheatup•Heavygauge,wrap-aroundsteelcabinet•Completefrontserviceaccess•Heavygaugealuminizedsteelheatexchanger•Slideoutblowerassembly•VariablespeedindoorblowerwithConstantTorqueECMblowermotor

•Rightandlefthandsideknockoutforventing•24voltfuse•Manualresetflamerolloutswitches•Twotonecolor•Non-prorated 20-year heat exchanger

limited warranty (Residential use)•5-year limited parts warranty•Optional extended warranties

Ref:1/12/0912:24pm

Effectivedate:January2,2009

FU – 8 Effective date: January 1, 2008© Trane 2007

TUD2A040 — D140A XL80 Induced Draft Gas Furnace Upflow/Horizontal Two-Stage

Specifications: Upflow/Horizontal Induced Draft Airflow Capacity(000) Uncrated Model In Tons Output-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 2 Stg 1 AFUE Size H W D Plant Weight

TUD2A040A9242A 2 32.0 20.8 80.0 4" 40 14.5 28 TR 119 TUD2A060A9362A 3 47.0 31.2 80.0 4" 40 14.5 28 TR 127TUD2B060A9362A 3 47.0 31.2 80.0 4" 40 17.5 28 TR 132 TUD2B080A9362A 3 63.0 41.6 80.0 4" 40 17.5 28 TR 142 TUD2B080A9482A 4 63.0 41.6 80.0 4" 40 17.5 28 TR 142 TUD2B100A9362A 3 79.0 52.0 80.0 4" 40 17.5 28 TR 151 TUD2C100A9482A 4 79.0 52.0 80.0 4" 40 21.0 28 TR 162 TUD2C100A9602A 5 80.0 52.0 80.0 4" 40 21.0 28 TR 162TUD2D100A9602A 5 80.0 52.0 80.0 4" 40 24.5 28 TR 175 TUD2C120A9542A 5 95.0 62.4 80.0 4" 40 21.0 28 TR 176 TUD2D120A9602A 5 95.0 62.4 80.0 4" 40 24.5 28 TR 186 TUD2D140A9602A 5 112.0 72.8 80.0 4" 40 24.5 28 TR 192 * Isolated Combustion System.

Accessories:Model Mfg. ShippingNumber Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit All TUD2 Furnaces TR 1BAYLPSS210B2 Propane Conversion Kit All TUD2 Furnaces TR 1 BAYHALT249 High Altitude Pressure Switch Kit All TUD2 (& later) Furnaces TR 2BAYVENT800B Masonry Chimney Vent Kit All TUD2 Furnaces TR 2BAYFLTR200 Side Filter Rack Kit-External All TUD2 (& later) Furnaces TR 5BAYFLTR317 Cleanable Filter Upflow 14.5"/17.5" Furnaces TR 2BAYFLTR321 Cleanable Filter Upflow 21" Furnaces TR 2BAYFLTR324 Cleanable Filter Upflow 24.5" Furnaces TR 2BAYRACK960A1 Filter Rack Kit All TUD2 (& later) Furnaces TR 51 Available for models with 1800 CFM or greater which require an additional side return. Includes 17" cleanable filter.2 With stainless steel burners.

• Insulatedblowerdoor•Gasketedblowerdoor•Twotonecolor•Heavygaugealuminizedsteelheat

exchanger•Multi-portIn-shotburners•Completefrontserviceaccess•Alternatebottom/left/rightreturnair•Slideoutblowerassembly•Directdrive,4-speedmotors•Commonventcapability•OptionalL.Pconversionkit

Features:•Upflow/Horizontal•Powersupply115/1/60•2-stagegasvalve•2-speedventer•2heatingblowerspeeds•SiliconNitridehotsurfaceigniterwith

adaptive heat up• Integratedsolidstatecontrolwith

self-diagnostics•Singlewiretwinning•Attractivecoloraccents•Perfectfitdoorlatches

•Left/rightgasconnection•Accessoryhook-upcapability•Selectablecoolingfanoffeliminatesneedfor

BAY24X045 time delay relay•24voltfuse•Manualresetflamerolloutswitches•Non-prorated 20-year heat exchanger

limited warranty (Residential use)•5-year limited parts warranty•Optional extended warranties

Ref

: 9/2

2/08

9:0

0 am

Effective date: August 7, 2008

FU – 9 Effective date: January 1, 2008© Trane 2007

•SiliconNitridehotsurfaceigniterwithadaptive heat up•Commonventcapability•Singlewiretwinning•Accessoryhook-upcapability•Convertibletohorizontal•Innerblowerdoorpanel• Integratedsolidstatecontrolwith

self-diagnostics•Selectablecoolingfanoffdelayeliminates

need for BAY24X045 time delay relay

TDD2A040 — D140A XL80 Downflow/Horizontal Gas Furnace Two-Stage

Specifications: Downflow/Horizontal Induced Draft Airflow Capacity(000) Uncrated Model In Tons Output-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 2 Stg 1 AFUE Size H W D Plant Weight

TDD2A040A9242A 2 32.0 20.8 80.0 4" 40 14.5 28 TR 125 TDD2A060A9362A 3 47.0 31.2 80.0 4" 40 14.5 28 TR 135 TDD2B060A9362A 3 48.0 31.2 80.0 4" 40 17.5 28 TR 140TDD2B080A9362A 3 64.0 41.6 80.0 4" 40 17.5 28 TR 152 TDD2B100A9482A 4 79.0 52.0 80.0 4" 40 17.5 28 TR 157 TDD2C100A9482A 4 79.0 52.0 80.0 4" 40 21.0 28 TR 166 TDD2C100A9602A 5 79.0 52.0 80.0 4" 40 21.0 28 TR 168 TDD2D120A9602A 5 94.0 62.4 80.0 4" 40 24.5 28 TR 189 TDD2D140A9602A 5 112.0 72.8 80.0 4" 40 24.5 28 TR 196

*Isolated Combustion System

Accessories:Model Mfg. ShippingNumber Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit All TDD2 Furnaces TR 1BAYLPSS210B1 Propane Conversion Kit All TDD2 Furnaces TR 1 BAYFLTR206 Filter Access Door Kit All TDD2 Furnaces TR 2BAYBASE205 Downflow Subbase All TDD2 Furnaces TR 8BAYHALT249 High Alt. Pressure Switch Kit All TDD2 Furnaces TR 21 With stainless steel burners.

Features:•Powersupply115/1/60•2-stagegasvalve•2-speedventer•Heavygaugealuminizedsteelheat

exchanger•Multi-portIn-shotburners•Completefrontserviceaccess•Alternatebottom/left/rightreturnair•Slideoutblowerassembly•Directdrive,4-speedmotors•OptionalL.Pconversionkit•Left/rightgasconnection

• Insulatedblowerdoor•Right-handsideknockoutforventing•24voltfuse•Manualresetflamerolloutswitches•Non-prorated 20-year heat exchanger

limited warranty (Residential use)•1-year limited warranty on parts•Optional extended warranties

FU – 10 Effective date: January 1, 2008© Trane 2007

TUD060 — 140R XV80 TDD060 — 120R Variable Speed Gas Furnace Two-StageSpecifications: Upflow/Horizontal Induced Draft Airflow Capacity (000) Uncrated Model In Tons Output-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 2 Stg 1 AFUE Size H W D Plant WeightTUD060R9V3K 3 48.0 31.2 80.0 4" 40 17.5 28 TR 136 TUD080R9V3K 3 64.0 41.6 80.0 4" 40 17.5 28 TR 142TUD080R9V4K 4 64.0 41.6 80.0 4" 40 21.0 28 TR 166TUD100R9V3K 3 80.0 52.0 80.0 4" 40 17.5 28 TR 142 TUD100R9V5K 5 79.0 52.0 80.0 4" 40 21.0 28 TR 166 TUD120R9V5K 5 97.0 62.4 80.0 4" 40 24.5 28 TR 193 TUD140R9V5K 5 111.0 72.8 80.0 4" 40 24.5 28 TR 197

Specifications: Downflow/Horizontal Induced Draft Airflow Capacity (000) Uncrated Model In Tons Output-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 2 Stg 1 AFUE Size H W D Plant Weight

TDD060R9V3F 3 48.0 31.2 80.0 4" 40 17.5 28 TR 140TDD080R9V3F 3 63.0 41.6 80.0 4" 40 17.5 28 TR 146 TDD100R9V5F 5 81.0 52.0 80.0 4" 40 21.0 28 TR 166 TDD120R9V5F 5 95.0 62.4 80.0 4" 40 24.5 28 TR 197 * Isolated Combustion System.

Accessories:Model Mfg. ShippingNumber Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit All TUD-R-K/TDD-R-F Furnaces TR 1BAYLPSS210B2 Propane Conversion Kit All TUD-R-K/TDD-R-F Furnaces TR 1 BAYFLTR206 Filter Access Door Kit All TDD-R-F Furnaces TR 2BAYBASE205 Downflow Subbase All TDD-R-F Furnaces TR 8BAYHALT249 High Alt. Pressure Switch Kit All TUD-R-K/TDD-R-F Furnaces TR 2BAYVENT800B Masonry Chimney Vent Kit All TUD060,080,100,120, TR 2 140 R9V Models BAYFLTR200 Side Filter Rack Kit-External All TUD-R-K (& later) Furnaces TR 5BAYRACK960A1 Filter Rack Kit-Internal All TUD-R-K (& later) Furnaces TR 51 Available for models with 1800 CFM or greater which require an additional side return. Includes 17" cleanable filter.2 With stainless steel burners.

Features:•Upflow/Horizontal&Downflow/Horizontal•Powersupply115/1/60•2-stagegasvalve•2-speedventer•SiliconNitridehotsurfaceigniterwith

adaptive heat up• Integratedsolidstatecontrol•Attractivecoloraccents•Heavygaugealuminizedsteelheat

exchanger•Multi-portIn-shotburners•Completefrontserviceaccess•Alternatebottom/left/rightreturnair•Slideoutblowerassembly

•Perfectfitdoorcatches• Insulatedblowerdoor•Gasketedblowerdoor• Internalfilterrack•Standardfiltersizes•Twotonecolor•VariablespeedECMblowermotor•TDDmodelshaverightandlefthandside

knockout for venting• Integratedsolidstatecontrolwith self-diagnostics•Commonventcapability•Cleanableframedfilters

•OptionalL.P.conversionkit•Left/rightgasconnection•Accessoryhook-upcapability•Innerblowerdoorpanel–TDDmodelsonly•Selectablecoolingfanoffdelayeliminates

need for BAY24X045time delay kit•Enhancedcoolingcontrol•Non-prorated 20-year heat exchanger

limited warranty (Residential use)•5-year limited parts warranty•Optional extended warranties

Ref

: 9/2

2/08

9:0

0 am

Effective date: August 7, 2008

FU – 11 Effective date: January 1, 2008© Trane 2007

TUD2B060 — D120A XV80i Induced Draft Gas Furnace Upflow/Horizontal Two-Stage with Whole House Air CleanerSpecifications: Upflow/Horizontal Induced Draft Airflow Capacity(000) Uncrated Model In Tons Output-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 2 Stg 1 AFUE Size H W D Plant Weight

TUD2B060AFV32A 3 48.0 31.2 80.0 4" 40 17.5 28 TR 136 TUD2B080AFV32A 3 64.0 41.6 80.0 4" 40 17.5 28 TR 142 TUD2C080AFV42A 4 64.0 41.6 80.0 4" 40 21.0 28 TR 166 TUD2B100AFV32A 3 80.0 52.0 80.0 4" 40 17.5 28 TR 142 TUD2D120AFV52A 5 97.0 62.4 80.0 4" 40 24.5 28 TR 193 * Isolated Combustion System.

Accessories:Model Mfg. ShippingNumber Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit All TUD2-F Furnaces TR 1BAYLPSS210B1 Propane Conversion Kit All TUD2-F Furnaces TR 1 BAYHALT249 High Altitude Pressure Switch Kit All TUD2-F Furnaces TR 2BAYVENT800B Masonry Chimney Vent Kit All TUD2-F Furnaces TR 21 With stainless steel burners.

•Heavygaugealuminizedsteelheatexchanger•Multi-portIn-shotburners•Completefrontserviceaccess•Slideoutblowerassembly•VariablespeedindoorblowerwithECMmotor•Commonventcapability•OptionalL.Pconversionkit•Left/rightgasconnection•Accessoryhook-upcapability•Selectablecoolingfanoffeliminatesneedfor

BAY24X045 time delay relay•Fused24voltcontrolcircuit•Manualresetflamerolloutswitches•Non-prorated 20-year heat exchanger

limited warranty (Residential use)•Optional extended warranties•5-year limited parts warranty

Features:•Equipped with integrated TRANE

CleanEffects™ Whole House Air Cleaner that removes up to 99% of allergens from the filtered air•Removesparticlesdownto.3micronsinsize•OutperformsHEPA,andupto100times

more effective than a standard 1" filter•Upflow/Horizontal•Powersupply115/1/60•2-stagegasvalve•2-speedventer•2heatingblowerspeeds•SiliconNitridehotsurfaceigniterwith

adaptive heat up• Integratedsolidstatecontrolwith

self-diagnostics• Insulatedblowerdoor•Gasketedblowerdoor•Twotonecolor

FU – 41 Effective date: January 1, 2008© Trane 2007 FU – 11A Effective date: October 10, 2008

Ref

: 11/

7/08

10:

14 a

m

TUD2B060 — D140A XC80 TDD2B060 — D120A Communicating Upflow/Horizontal Variable Speed Downflow/Horizontal Gas Furnace Two-StageSpecifications: Upflow/Horizontal Induced Draft Airflow Capacity (000) Uncrated Model In Tons Output-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 2 Stg 1 AFUE Size H W D Plant WeightTUD2B060ACV32A 3 48.0 31.2 80.0 4" 40 17.5 28 TR 136 TUD2B080ACV32A 3 64.0 41.6 80.0 4" 40 17.5 28 TR 142TUD2C080ACV42A 4 64.0 41.6 80.0 4" 40 21.0 28 TR 166TUD2B100ACV32A 3 80.0 52.0 80.0 4" 40 17.5 28 TR 142 TUD2C100ACV52A 5 79.0 52.0 80.0 4" 40 21.0 28 TR 166 TUD2D120ACV52A 5 97.0 62.4 80.0 4" 40 24.5 28 TR 193 TUD2D140ACV52A 5 111.0 72.8 80.0 4" 40 24.5 28 TR 197

Specifications: Downflow/Horizontal Induced Draft Airflow Capacity (000) Uncrated Model In Tons Output-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 2 Stg 1 AFUE Size H W D Plant Weight

TDD2B060ACV32A 3 48.0 31.2 80.0 4" 40 17.5 28 TR 140TDD2B080ACV32A 3 63.0 41.6 80.0 4" 40 17.5 28 TR 146 TDD2C100ACV52A 5 81.0 52.0 80.0 4" 40 21.0 28 TR 166 TDD2D120ACV52A 5 95.0 62.4 80.0 4" 40 24.5 28 TR 197 * Isolated Combustion System.

Accessories:Model Mfg. ShippingNumber Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit All TUD2-ACV/TDD2-ACV Furnaces TR 1BAYLPSS210B2 Propane Conversion Kit All TUD2-ACV/TDD2-ACV Furnaces TR 1 BAYFLTR206 Filter Access Door Kit All TDD2-ACV Furnaces TR 2BAYBASE205 Downflow Subbase All TDD2-ACV Furnaces TR 8BAYHALT249 High Alt. Pressure Switch Kit All TUD2-ACV/TDD2-ACV Furnaces TR 2BAYVENT800B Masonry Chimney Vent Kit All TUD2-ACV Furnaces TR 2BAYFLTR200 Side Filter Rack Kit-External All TUD2-ACV Furnaces TR 5BAYRACK960A1 Filter Rack Kit-Internal All TUD2-ACV Furnaces TR 5BAYACCECOMM101 CleanEffects™ Hook-up Kit All TUD2-ACV/TDD2-ACV Furnaces TR 11 Available for models with 1800 CFM or greater which require an additional side return. Includes 17" cleanable filter.2 With stainless steel burners.

Features:•ComfortLink™ II Communication3 or 24 Volt4

control•Factorydefaultiscommunication.Field

configurable 24 volt mode•Forusewithcommunicatingoutdoorproducts,

single stage - cooling only outdoor units, or single or two stage outdoor units in 24 Volt operation•Plugandplayinstallationincommunication

mode with communicating Comfort Control•ThreewireconnectionstoComfortControl

when used with communicating Comfort Control (TCONT900AC43UA)•Twospeedinducermotor•Storedfaultcodehistoryinmicroprocessor

non-volatile memory

•Slideoutblowerassembly•VariablespeedECMblowermotorwith

continuous Comfort-R™

•SiliconNitridehotsurfaceigniterwithadaptive heat up•Manualresetflamerolloutswitches•Powersupply115/1/60•ConvertibletoHorizontalLeft•2-stagemodulatinggasvalve•Accessoryhook-upcapability• Integratedsolidstatecontrolwith

self-diagnostics• ImprovedCleanEffects™ connections•Attractivecoloraccents•Heavygaugealuminizedsteelheat

exchanger

•Multi-portIn-shotburners• Insulatedblowerdoor•Gasketedblowerdoor•Completefrontserviceaccess•Left/rightgasconnection•OptionalL.Pconversionkit•Non-prorated 20-year heat exchanger

limited warranty (Residential use)•5-year limited parts warranty •Optional extended warranties3 Requires comfort control TCONT900AC43UA.4 Requires 24 volt comfort control.

FU – 12 Effective date: January 1, 2008© Trane 2007

TUC1B040 — D120A XB90 DV Direct Vent/ Condensing Non-Direct Vent Gas Furnace Single StageSpecifications: Upflow/Horizontal Condensing (Sealed Combustion -1 or 2 Pipe Vent Option) Airflow Nominal PVC Uncrated Model In Tons Cap-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Htg Output AFUE Size H W D Plant Weight

TUC1B040A9241A 2 38,000 92.1 2,2½,3" 40 17.5 28 TR 139 TUC1B060A9361A 3 56,000 92.1 2,2½,3" 40 17.5 28 TR 150 TUC1B080A9421A 3.5 74,000 92.1 2,2½,3" 40 17.5 28 TR 158 TUC1C100A9481A 4 94,000 92.1 2½,3" 40 21.0 28 TR 171 TUC1D100A9601A 5 93,000 92.1 2½,3" 40 24.5 28 TR 197 TUC1D120A9601A 5 113,000 92.1 2½,3" 40 24.5 28 TR 205 * Isolated Combustion System.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Comfort Controls Section)BAYLPKT210B Propane Conversion Kit TUC1 Furnaces TR 1BAYLPSS210B1 Propane Conversion Kit TUC1 Furnaces TR 1 BAY69X147 Wall Mount Flange-3" TUC1 Furnaces TR 1 BAY69X148 Wall Mount Flange-2" TUC1 Furnaces TR 1BAYRACK960A2 Filter Rack Kit - Internal TUC1 Furnaces TR 5 BAYFLTR200 Side Filter Rack - External TUC1 Furnaces TR 5 BAYFLTR317 Cleanable Filter Upflow 17.5" Furnaces TR 2BAYFLTR321 Cleanable Filter Upflow 21" Furnaces TR 2BAYFLTR324 Cleanable Filter Upflow 24.5" Furnaces TR 2BAYSWT01AHALTA High Altitude Pressure Switch Kit TUC1B040,D100 TR 2BAYSWT02AHALTA High Altitude Pressure Switch Kit TUC1B060 TR 2BAYSWT03AHALTA High Altitude Pressure Switch Kit TUC1B080 TR 2 BAYSWT04AHALTA High Altitude Pressure Switch Kit TUC1C100,D120 TR 2 BAYAIR30AVENTA Concentric Vent Kit TUC1 Furnaces TR 11 BAYVENT200B Sidewall Vent Termination Kit All 2 Pipe Direct Vent Furnaces TR 2BAYMFGH100A Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces TR 2 1 With stainless steel burners.2 Internal filter rack for side or bottom return air. Includes 17.5" cleanable filter. *For heating/cooling thermostats see outdoor sections.

•Dualsolenoidcombinationgasvalve&regulator•PVCventing-1or2pipeventoption•Left/rightgasconnection•Selectablecoolingfanoffdelayeliminates

need for BAY24X045 time delay relay• Integratedsolidstatecontrolwith

self-diagnostics•24voltfuse

Features:•Powersupply115/1/60•Convertibletohorizontalleftairflow•Type 29-4C™ stainless steel secondary heat exchanger•Directdrive,4-speedmotors•SiliconCarbideigniterwithadaptiveheatup•Accessoryhook-upcapability-HumandEAC•Quietinduceddraftblower•Blowerdoorsafetyswitch

•Manualresetburnerboxlimit•20-year limited primary heat exchanger

or secondary heat exchanger warranty to original owner (Residential use)•5-year limited parts warranty•Optional extended warranties

FU – 13 Effective date: January 1, 2008© Trane 2007

TDC1B040 — D120A XB90 DV Direct Vent/ Condensing Non-Direct Vent Gas Furnace Single Stage

Specifications: Downflow/Horizontal Condensing (Sealed Combustion -1 or 2 Pipe Vent Option) Airflow Nominal PVC Uncrated Model In Tons Cap-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Htg Output AFUE Size H W D Plant Weight

TDC1B040A9241A 2 38,000 91.0 2,2½,3" 40 17.5 28 TR 145 TDC1B060A9361A 3 56,000 91.0 2,2½,3" 40 17.5 28 TR 155 TDC1B080A9421A 3.5 74,000 91.0 2,2½,3" 40 17.5 28 TR 168 TDC1C100A9481A 4 94,000 91.0 2½,3" 40 21.0 28 TR 185 TDC1D120A9601A 5 112,000 91.0 2½,3" 40 24.5 28 TR 206 * Isolated Combustion System.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

Extended Warranties – (See Extended Warranty Section) Controls (See Comfort Controls Section)BAYLPKT210B Propane Conversion Kit TDC1 Furnaces TR 1BAYLPSS210B1 Propane Conversion Kit TDC1 Furnaces TR 1 BAY69X147 Wall Mount Flange-3" TDC1 Furnaces TR 1 BAY69X148 Wall Mount Flange-2" TDC1 Furnaces TR 1 BAYBASE205 Downflow Subbase TDC1 Furnaces TR 8BAYFLTR206 Filter Access Door Kit TDC1 Furnaces TR 2 BAYSWT01AHALTA High Altitude Pressure Switch Kit TDC1B040 TR 2BAYSWT04AHALTA High Altitude Pressure Switch Kit TDC1B080,D120 TR 2 BAYSWT05AHALTA High Altitude Pressure Switch Kit TDC1C100 TR 2 BAYSWT06AHALTA High Altitude Pressure Switch Kit TDC1B060 TR 2 BAYAIR30AVENTA Concentric Vent Kit TDC1 Furnaces TR 11 BAYVENT200B Sidewall Vent Termination Kit All 2 Pipe Direct Vent Furnaces TR 2BAYMFGH100A Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces TR 21 With stainless steel burners.

•Dualsolenoidcombinationgasvalve&regulator•PVCventing-1or2pipeventoption•Left/rightgasconnection•Selectablecoolingfanoffdelayeliminates

need for BAY24X045 time delay relay• Integratedsolidstatecontrolwithself-

diagnostics•24voltfuse•Manualresetburnerboxlimit

Features:•Powersupply115/1/60•Convertibletohorizontalrightairflow•Type 29-4C™ stainless steel

secondary heat exchanger•Innerblowerdoors•Directdrive,4-speedmotors•SiliconCarbideigniterwithadaptiveheatup•Accessoryhook-upcapability-HumandEAC•Quietinduceddraftblower•Blowerdoorsafetyswitch

•20-year limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use)•5-year limited parts warranty •Optional extended warranties

FU – 14 Effective date: January 1, 2008© Trane 2007

TUX1B040 — D120A XR90 DV Direct Vent/ Condensing Non-Direct Vent Gas Furnace Single StageSpecifications: Upflow/Horizontal Condensing (Sealed Combustion -1 or 2 Pipe Vent Option) Airflow Nominal Uncrated Model In Tons Cap-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Htg Output AFUE Size H W D Plant Weight

TUX1B040A9241A 2 38,000 92.1 2,2½,3" 40 17.5 28 TR 139TUX1B060A9241A 2 56,000 92.1 2,2½,3" 40 17.5 28 TR 150TUX1B060A9361A 3 56,000 92.1 2,2½,3" 40 17.5 28 TR 150TUX1B080A9241A 2 74,000 92.1 2,2½,3" 40 17.5 28 TR 158 TUX1B080A9421A 3.5 74,000 92.1 2,2½,3" 40 17.5 28 TR 158TUX1C080A9601A 5 76,000 92.1 2,2½,3" 40 21.0 28 TR 171TUX1C100A9361A 3 94,000 92.1 2½,3" 40 21.0 28 TR 171 TUX1C100A9481A 4 94,000 92.1 2½,3" 40 21.0 28 TR 171 TUX1D100A9601A 5 93,000 92.1 2½,3" 40 24.5 28 TR 197 TUX1D120A9601A 5 113,000 92.1 2½,3" 40 24.5 28 TR 205 * Isolated Combustion System.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit TUX1 Furnaces TR 1BAYLPSS210B1 Propane Conversion Kit TUX1 Furnaces TR 1 BAY69X147 Wall Mount Flange-3" TUX1 Furnaces TR 1 BAY69X148 Wall Mount Flange-2" TUX1 Furnaces TR 1BAYRACK960A2 Filter Rack Kit - Internal TUX1 Furnaces TR 5 BAYFLTR200 Side Filter Rack - External TUX1 Furnaces TR 5 BAYFLTR317 Cleanable Filter Upflow 17.5" Furnaces TR 2BAYFLTR321 Cleanable Filter Upflow 21" Furnaces TR 2BAYFLTR324 Cleanable Filter Upflow 24.5" Furnaces TR 2BAYSWT01AHALTA High Altitude Pressure Switch Kit TUX1B040,D100 TR 2BAYSWT02AHALTA High Altitude Pressure Switch Kit TUX1B060 TR 2BAYSWT03AHALTA High Altitude Pressure Switch Kit TUX1B080 TR 2 BAYSWT04AHALTA High Altitude Pressure Switch Kit TUX1C100,D120 TR 2BAYSWT01AMALTB Medium Altitude Conversion Kit TUX1C100,D120 TR 2 BAYAIR30AVENTA Concentric Vent Kit TUX1 Furnaces TR 11 BAYVENT200B Sidewall Vent Termination Kit All 2 Pipe Direct Vent Furnaces TR 2BAYMFGH100A Manufactured/MobileHomeKit All2PipeDirectVentFurnaces TR 2*For heating/cooling thermostats see outdoor sections. 1 With stainless steel burners. 2 Internal filter rack for side or bottom return air. Includes 17" cleanable filter.

•Left/rightgasconnection•Singlewiretwinning•Perfectfitdoorlatches• Insulatedblowerdoor•Gasketedblowerdoor•Twotonecolor•Selectablecoolingfanoffdelayeliminates

need for BAY24X045 time delay relay• Integratedsolidstatecontrolwith

self-diagnostics•24voltfuse•Manualresetburnerboxlimit

Features:•Powersupply115/1/60•Convertibletohorizontalleft•Type 29-4C™ stainless steel secondary heat

exchanger•Directdrive,4-speedmotors•SiliconNitrideigniterwithadaptiveheatup•Accessoryhook-upcapability-HumandEAC•Quietinduceddraftblower•Blowerdoorsafetyswitch•Dualsolenoidcombinationgasvalve&

regulator•PVCventing-1or2pipeventoption

•Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use)•5-year limited parts warranty•Optional extended warranties

Ref

: 9/2

2/08

9:0

0 am

Effective date: August 7, 2008

FU – 15 Effective date: January 1, 2008© Trane 2007

TDX1B040 — D120A XR90 DV Direct Vent/ Condensing Non-Direct Vent Gas Furnace Single Stage

Specifications: Downflow/Horizontal Condensing (Sealed Combustion -1 or 2 Pipe Vent Option) Airflow Nominal Uncrated Model In Tons Cap-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Htg Output AFUE Size H W D Plant Weight

TDX1B040A9241A 2 38,000 91.0 2,2½,3" 40 17.5 28 TR 145 TDX1B060A9361A 3 56,000 91.0 2,2½,3" 40 17.5 28 TR 155 TDX1B080A9421A 3.5 74,000 91.0 2,2½,3" 40 17.5 28 TR 168 TDX1C100A9481A 4 94,000 91.0 2½,3" 40 21.0 28 TR 185 TDX1D120A9601A 5 112,000 91.0 2½,3" 40 24.5 28 TR 206 * Isolated Combustion System.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit TDX1 Furnaces TR 1BAYLPSS210B1 Propane Conversion Kit TDX1 Furnaces TR 1 BAY69X147 Wall Mount Flange-3" TDX1 Furnaces TR 1 BAY69X148 Wall Mount Flange-2" TDX1 Furnaces TR 1 BAYBASE205 Downflow Subbase TDX1 Furnaces TR 8BAYFLTR206 Filter Access Door Kit TDX1 Furnaces TR 2 BAYSWT01AHALTA High Altitude Pressure Switch Kit TDX1B040 TR 2BAYSWT04AHALTA High Altitude Pressure Switch Kit TDX1B080,D120 TR 2 BAYSWT05AHALTA High Altitude Pressure Switch Kit TDX1C100 TR 2 BAYSWT06AHALTA High Altitude Pressure Switch Kit TDX1B060 TR 2BAYSWT01AMALTB Medium Altitude Conversion Kit TDX1C100,D120 TR 2 BAYAIR30AVENTA Concentric Vent Kit TDX1 Furnaces TR 11 BAYVENT200B Sidewall Vent Termination Kit All 2 Pipe Direct Vent Furnaces TR 2BAYMFGH100A Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces TR 21 With stainless steel burners.

•Dualsolenoidcombinationgasvalve&regulator•PVCventing-1or2pipeventoption•Left/rightgasconnection•Selectablecoolingfanoffdelayeliminates

need for BAY24X045 time delay relay•Singlewiretwinning• Integratedsolidstatecontrolwith

self-diagnostics•24voltfuse

Features:•Powersupply115/1/60•Convertibletohorizontalleft•Type 29-4C™ stainless steel

secondary heat exchanger•Innerblowerdoors•Directdrive,4-speedmotors•SiliconNitrideigniterwithadaptiveheatup•Accessoryhook-upcapability-HumandEAC•Quietinduceddraftblower•Blowerdoorsafetyswitch

•Manualresetburnerboxlimit•Lifetime limited primary heat exchanger

or secondary heat exchanger warranty to original owner (Residential use)•5-year limited parts warranty •Optional extended warranties

FU – 16 Effective date: January 1, 2008© Trane 2007

TUX1 - H XT90 DV Direct Vent/ Condensing Non-Direct Vent Gas Furnace Single Stage High Efficiency MotorSpecifications: Upflow/Horizontal Condensing (Sealed Combustion -1 or 2 Pipe Vent Option) Airflow Nominal Uncrated Model In Tons Cap-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Htg Output AFUE Size H W D Plant Weight

TUX1B040A9H21B 2 38,000 92.1 2,2½,3" 40 17.5 28 TR 139TUX1B060A9H31B 3 56,000 92.1 2,2½,3" 40 17.5 28 TR 150TUX1B080A9H31B 3 74,000 92.1 2,2½,3" 40 17.5 28 TR 158TUX1C100A9H41B 4 94,000 92.1 2½,3" 40 21.0 28 TR 171TUX1D120A9H51B 5 113,000 92.1 2½,3" 40 24.5 28 TR 205*IsolatedCombustionSystem.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

ExtendedWarranties (SeeExtendedWarrantySection)Controls (SeeControlSection)BAYLPKT210B PropaneConversionKit TUX1-HFurnaces TR 1BAYLPSS210B1 PropaneConversionKit TUX1-HFurnaces TR 1BAY69X147 WallMountFlange-3" TUX1-HFurnaces TR 1BAY69X148 WallMountFlange-2" TUX1-HFurnaces TR 1BAYFLTR200 SideFilterRack-External TUX1-HFurnaces TR 5BAYFLTR317 CleanableFilter Upflow17.5"Furnaces TR 2BAYFLTR321 CleanableFilter Upflow21"Furnaces TR 2BAYFLTR324 CleanableFilter Upflow24.5"Furnaces TR 2BAYSWT01AHALTA HighAltitudePressureSwitchKit TUX1B040 TR 2BAYSWT02AHALTA HighAltitudePressureSwitchKit TUX1B060 TR 2BAYSWT03AHALTA HighAltitudePressureSwitchKit TUX1B080 TR 2BAYSWT04AHALTA HighAltitudePressureSwitchKit TUX1C100,D120 TR 2BAYAIR30AVENTA ConcentricVentKit TUX1-HFurnaces TR 11BAYVENT200B SidewallVentTerminationKit All2PipeDirectVentFurnaces TR 2BAYMFGH100A Manufactured/MobileHomeKit All2PipeDirectVentFurnaces TR 21Withstainlesssteelburners.

•Perfectfitdoorlatches• Insulatedblowerdoor•Gasketedblowerdoor•Twotonecolor• Internalfilterrackacceptsstandardfiltersizes•Cleanablehighvelocityfilters•SelectablecoolingfanoffdelayeliminatesneedforBAY24X045timedelayrelay•Singlewiretwinning• Integratedsolidstatecontrolwithself-diagnostics•24voltfuse•Manualresetburnerboxlimit

Features:•Powersupply115/1/60•Convertibletohorizontalleft•Type 29-4C™stainlesssteel secondaryheatexchanger•VariablespeedindoorblowerwithConstantTorqueECMblowermotor•SiliconNitrideigniterwithadaptiveheatup•Accessoryhook-upcapability-HumandEAC•Quietinduceddraftblower•Blowerdoorsafetyswitch•Dualsolenoidcombinationgasvalve&regulator•PVCventing-1or2pipeventoption•Left/rightgasconnection

•Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use)•5-year limited parts warranty •Optional extended warranties

Ref:1/12/0912:24pm

Effectivedate:January2,2009

FU – 17 Effective date: January 1, 2008© Trane 2007

TDX1 - H XT90 DV Direct Vent/ Condensing Non-Direct Vent Gas Furnace Single Stage High Efficiency MotorSpecifications: Downflow/Horizontal Condensing (Sealed Combustion -1 or 2 Pipe Vent Option) Airflow Nominal Uncrated Model In Tons Cap-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Htg Output AFUE Size H W D Plant Weight

TDX1B040A9H21B 2 38,000 91.0 2,2½,3" 40 17.5 28 TR 145TDX1B060A9H31B 3 56,000 91.0 2,2½,3" 40 17.5 28 TR 155TDX1B080A9H31B 3 74,000 91.0 2,2½,3" 40 17.5 28 TR 168TDX1C100A9H41B 4 94,000 91.0 2½,3" 40 21.0 28 TR 185TDX1D120A9H51B 5 112,000 91.0 2½,3" 40 24.5 28 TR 206*IsolatedCombustionSystem.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

ExtendedWarranties (SeeExtendedWarrantySection)Controls (SeeControlSection)BAYLPKT210B PropaneConversionKit TDX1-HFurnaces TR 1BAYLPSS210B1 PropaneConversionKit TDX1-HFurnaces TR 1BAY69X147 WallMountFlange-3" TDX1-HFurnaces TR 1BAY69X148 WallMountFlange-2" TDX1-HFurnaces TR 1BAYBASE205 DownflowSubbase TDX1-HFurnaces TR 8BAYFLTR206 FilterAccessDoorKit TDX1-HFurnaces TR 2BAYSWT01AHALTA HighAltitudePressureSwitchKit TDX1B040 TR 2BAYSWT04AHALTA HighAltitudePressureSwitchKit TDX1B080,D120 TR 2BAYSWT05AHALTA HighAltitudePressureSwitchKit TDX1C100 TR 2BAYSWT06AHALTA HighAltitudePressureSwitchKit TDX1B060 TR 2BAYAIR30AVENTA ConcentricVentKit TDX1-HFurnaces TR 11BAYVENT200B SidewallVentTerminationKit All2PipeDirectVentFurnaces TR 2BAYMFGH100A Manufactured/MobileHomeKit All2PipeDirectVentFurnaces TR 2BAYFLTR317 CleanableFilter Upflow17.5"Furnaces TR 2BAYFLTR321 CleanableFilter Upflow21"Furnaces TR 2BAYFLTR324 CleanableFilter Upflow24.5"Furnaces TR 21Withstainlesssteelburners.

•Blowerdoorsafetyswitch•Dualsolenoidcombinationgasvalve&regulator•PVCventing-1or2pipeventoption•Left/rightgasconnection•SelectablecoolingfanoffdelayeliminatesneedforBAY24X045timedelayrelay•Singlewiretwinning• Integratedsolidstatecontrolwithself-diagnostics•24voltfuse•Manualresetburnerboxlimit

Features:•Powersupply115/1/60•Convertibletohorizontalleft•Type 29-4C™stainlesssteelsecondaryheatexchanger•Innerblowerdoors•VariablespeedindoorblowerwithConstantTorqueECMblowermotor• Internalfilterrackacceptsstandardfiltersizes•Cleanablehighvelocityfilters•SiliconNitrideigniterwithadaptiveheatup•Accessoryhook-upcapability-HumandEAC•Quietinduceddraftblower

•Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use)•5-year limited parts warranty •Optional extended warranties

Ref:1/12/0912:24pm

Effectivedate:January2,2009

FU – 18 Effective date: January 1, 2008© Trane 2007

TUX2B060 — D120A XL90 Upflow/Horizontal Two Stage Direct/Non-Direct Vent Condensing Gas Furnace

Specifications: Upflow/Horizontal Condensing (Sealed Combustion - 1 or 2 Pipe Vent Option) Airflow Capacity (000) Uncrated Model In Tons Output-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 2 Stg 1 AFUE Size H W D Plant Weight

TUX2B060A9362A 3 56.0 36.0 93.0 2,2½,3" 40 17.5 28 TR 156TUX2B080A9422A 3 73.0 48.0 92.5 2,2½,3" 40 17.5 28 TR 168 TUX2C100A9482A 4 93.0 60.0 93.0 2½, 3" 40 21.0 28 TR 197 TUX2D120A9602A 5 112.0 66.6 92.5 3" 40 24.5 28 TR 206 * Isolated Combustion System.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit All TUX2 Furnaces TR 1BAYLPSS210B2 Propane Conversion Kit All TUX2 Furnaces TR 1 BAYFLTR200 Side Filter Rack - External All TUX2 Furnaces TR 5BAYRACK960A3 Filter Rack Kit-Internal All TUX2 Furnaces TR 5BAYFLTR203 FilterKit/HorizontalConversion TUX2B060,080 TR 3BAYFLTR204 FilterKit/HorizontalConversion TUX2C100 TR 3BAYFLTR205 FilterKit/HorizontalConversion TUX2D120 TR 3BAYFLTR317 Cleanable Filter Upflow 17.5" Furnaces TR 2BAYFLTR321 Cleanable Filter Upflow 21" Furnaces TR 2BAYFLTR324 Cleanable Filter Upflow 24.5" Furnaces TR 2BAYSWT07AHALTA1 High Altitude Kit TUX2B060 TR 2BAYSWT08AHALTA1 High Altitude Kit TUX2B080,TUX2C100 TR 2BAYSWT09AHALTA1 High Altitude Kit TUX2D120 TR 2BAYAIR30AVENTA Concentric Vent Kit All TUX2 Furnaces TR 11BAYVENT200B Sidewall Vent Termination Kit All TUX2 Furnaces TR 2BAYMFGH100A Manufactured/MobileHomeKit All2PipeDirectVentFurnaces TR 21Optionalkitallows200ft.max.ventlengthfrom5,000-12,000feetabovesealevel.Seeinstaller'sguide.2 With stainless steel burners.3 Internal filter rack for side or bottom return air. Includes 17" cleanable filter.

•Heavygaugealuminizedsteelheatexchanger•Singlewiretwinning•Perfectfitdoorlatches• Insulatedblowerdoor•Gasketedblowerdoor•Twotonecolor•Multi-portIn-shotburners•Completefrontserviceaccess•Left/rightgasconnection•Adjustablefanofftimes•OptionalL.Pconversionkit•Selectablecoolingfanoffdelayeliminates

need for BAY24X045 time delay kit

Features:•DirectDrive-4speedPSCMotor•SiliconNitrideIgniterwithadaptiveheatup•Variablespeedinduceddraftblower•Direct/Non-Directventoption•Fused24voltcontrolcircuit•Manualresetburnersafetyswitches•Powersupply115/1/60•Convertibletohorizontalonleftside•2-stagegasvalve•PVCventing-1or2pipeoption•Accessoryhook-upcapability• Integratedsolidstatecontrolwith

self-diagnostics•Attractivecoloraccents

•Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use)•5-year limited parts warranty •Optional extended warranties

Ref

: 9/2

2/08

9:0

0 am

Effective date: August 7, 2008

FU – 19 Effective date: January 1, 2008© Trane 2007

•Multi-portIn-shotburners•Singlewiretwinning•Completefrontserviceaccess•Left/rightgasconnection•Adjustablefanofftimes•OptionalL.Pconversionkit•Selectablecoolingfanoffdelayeliminates

need for BAY24X045 time delay kit•Lifetime limited primary heat exchanger

or secondary heat exchanger warranty to original owner (Residential use)•5-year limited parts warranty •Optional extended warranties

Features:•Directdrive,4speedPSCmotor•SiliconNitrideIgniterwithadaptiveheatup•Variablespeedinduceddraftblower•Direct/Non-Directventoption•Fused24voltcontrolcircuit•Manualresetburnersafetyswitches•Powersupply115/1/60•Convertibletohorizontalonleftside•2-stagegasvalve•PVCventing-1or2pipeoption•Accessoryhook-upcapability• Integratedsolidstatecontrol•Attractivecoloraccents•Heavygaugealuminizedsteelheat

exchanger

TDX2B060 —D120A XL90 Downflow/Horizontal Two Stage Direct/Non-Direct Vent Condensing Gas Furnace

Specifications: Downflow/Horizontal Condensing (Sealed Combustion-1 or 2 Pipe Vent Option) Airflow Capacity (000) Uncrated Model In Tons Output-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 2 Stg 1 AFUE Size H W D Plant Weight

TDX2B060A9362A 3 55.0 36.0 92.0 2,2½,3" 40 17.5 28 TR 160 TDX2B080A9422A 3 74.0 48.0 92.5 2,2½,3" 40 17.5 28 TR 168 TDX2C100A9482A 4 93.0 60.0 93.0 2½, 3" 40 21.0 28 TR 185 TDX2D120A9602A 5 111.0 72.0 92.5 3" 40 24.5 28 TR 206

* Isolated Combustion System.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit All TDX2 Furnaces TR 1BAYLPSS210B2 Propane Conversion Kit All TDX2 Furnaces TR 1 BAYBASE205 Downflow Subbase All TDX2 Furnaces TR 8 BAYSWT07AHALTA1 High Altitude Kit TDX2B060 TR 2BAYSWT08AHALTA1 High Altitude Kit TDX2B080,TDX2C100 TR 2BAYSWT09AHALTA1 High Altitude Kit TDX2D120 TR 2BAYAIR30AVENTA Concentric Vent Kit All TDX2 Furnaces TR 11BAYVENT200B Sidewall Vent Termination Kit All TDX2 Furnaces TR 2BAYMFGH100A Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces TR 2BAYFLTR317 Cleanable Filter Upflow 17.5" Furnaces TR 2BAYFLTR321 Cleanable Filter Upflow 21" Furnaces TR 2BAYFLTR324 Cleanable Filter Upflow 24.5" Furnaces TR 21 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide.2 With stainless steel burners.

FU – 20 Effective date: January 1, 2008© Trane 2007

TUY060 — 120R XV90 Two Stage Upflow/Horizontal Variable Speed Direct/Non-Direct Vent Gas Furnace

Specifications:Upflow/Horizontal Condensing Induced Draft (Sealed Combustion -1 or 2 Pipe Vent Option) Airflow Capacity (000) Uncrated Model In Tons Output-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 2 Stg 1 AFUE Size H W D Plant Weight

TUY060R9V3W 3 56.0 37.0 93.0 2,2½,3" 40 17.5 28 TR 156TUY080R9V3W 3 73.0 48.0 92.5 2,2½,3" 40 17.5 28 TR 168 TUY100R9V4W 4 93.0 60.0 93.0 2½, 3" 40 21.0 28 TR 197 TUY120R9V5W 5 112.0 72.0 92.5 3" 40 24.5 28 TR 206

* Isolated Combustion System.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit All TUY Furnaces TR 1BAYLPSS210B2 Propane Conversion Kit All TUY Furnaces TR 1 BAYRACK960A3 Filter Rack Kit-Internal All TUY Furnaces TR 5BAYFLTR200 Side Filter Rack - External All TUY Furnaces TR 5BAYFLTR203 FilterKit/HorizontalConversion TUY060,080R TR 3BAYFLTR204 FilterKit/HorizontalConversion TUY100R TR 3BAYFLTR205 FilterKit/HorizontalConversion TUY120R TR 3BAYFLTR317 Filter Accessory Kit Upflow 14.5" Furnaces TR 2BAYFLTR321 Filter Accessory Kit Upflow 21" Furnaces TR 2BAYFLTR324 Filter Accessory Kit Upflow 24.5" Furnaces TR 2BAYSWT07AHALTA1 High Altitude Kit TUY060R TR 2BAYSWT08AHALTA1 High Altitude Kit TUY080,100R TR 2BAYSWT09AHALTA1 High Altitude Kit TUY120R TR 2BAYAIR30AVENTA Concentric Vent Kit All TUY Furnaces TR 11BAYVENT200B Sidewall Vent Termination Kit All TUY Furnaces TR 2BAYMFGH100A Manufactured/MobileHomeKit All2PipeDirectVentFurnaces TR 21Optionalkitallows200ft.max.ventlengthfrom5,000-12,000feetabovesealevel.Seeinstaller'sguide.2 With stainless steel burners.3 Internal filter rack for side or bottom return air. Includes 17" cleanable filter.

Features:•VariablespeedindoorblowerwithECMmotor•SiliconNitrideIgniterwithadaptiveheatup•Direct/Non-Directventoption•Fused24voltcontrolcircuit•Manualresetburnersafetyswitches•Powersupply115/1/60•Convertibletohorizontalonleftside•2-stagegasvalve•PVCventing-1or2pipeoption•Accessoryhook-upcapability• Integratedsolidstatecontrolwith

self-diagnostics•Attractivecoloraccents•Heavygaugealuminizedsteelheat

exchanger•Multi-portIn-shotburners•Perfectfitdoorlatches• Insulatedblowerdoor

•Gasketedblowerdoor• Internalfilterrack•Standardfiltersizes•Twotonecolor•Completefrontserviceaccess•Left/rightgasconnection•Adjustablefanofftimes•Cleanablehighvelocityfilters•OptionalL.Pconversionkit•Selectablecoolingfanoffdelayeliminatesneed

for BAY24X045 time delay kit•Lifetime limited primary heat

exchanger or secondary heat exchanger warranty to original owner

(Residential use)•5-year limited parts warranty •Optional extended warranties

Ref

: 9/2

2/08

9:0

0 am

Effective date: August 7, 2008

FU – 21 Effective date: January 1, 2008© Trane 2007

•Multi-portIn-shotburners•Completefrontserviceaccess•Left/rightgasconnection•Adjustablefanofftimes•Cleanablehighvelocityfilters•OptionalL.Pconversionkit•Selectablecoolingfanoffdelayeliminates

need for BAY24X045 (time delay kit)•Lifetime limited primary heat exchanger

or secondary heat exchanger warranty to original owner (Residential use)•5-year limited parts warranty •Optional extended warranties

Features:•VariablespeedblowerwithECMmotor•SiliconNitrideIgniterwithadaptiveheatup•Direct/Non-Directventoption•Fused24voltcontrolcircuit•Manualresetburnersafetyswitches•Powersupply115/1/60•Convertibletohorizontalonleftside•2-stagegasvalve•PVCventing-1or2pipeoption•Accessoryhook-upcapability•Quietinduceddraftblower• Integratedsolidstatecontrol•Attractivecoloraccents•Heavygaugealuminizedsteelheat

exchanger

TDY060 — 120R XV90 Two Stage Downflow/Horizontal Variable Speed Direct/Non-Direct Vent Gas Furnace

Specifications: Downflow/Horizontal Condensing Induced Draft (Sealed Combustion - 1 or 2 Pipe Vent Option) Airflow Capacity (000) Uncrated Model In Tons Output-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 2 Stg 1 AFUE Size H W D Plant Weight

TDY060R9V3W 3 56.0 36.0 92.0 2,2½,3" 40 17.5 28 TR 160 TDY080R9V3W 3 74.0 48.0 92.5 2,2½,3" 40 17.5 28 TR 168 TDY100R9V4W 4 94.0 60.0 93.0 2½, 3" 40 21.0 28 TR 185 TDY120R9V5W 5 112.0 72.0 92.5 3" 40 24.5 28 TR 206

* Isolated Combustion System.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit All TDY Furnaces TR 1BAYLPSS210B2 Propane Conversion Kit All TDY Furnaces TR 1 BAYBASE205 Downflow Subbase All TDY Furnaces TR 8 BAYSWT07AHALTA1 High Altitude Kit TDY060R TR 2BAYSWT08AHALTA1 High Altitude Kit TDY080,100R TR 2BAYSWT09AHALTA1 High Altitude Kit TDY120R TR 2BAYAIR30AVENTA Concentric Vent Kit All TDY Furnaces TR 11BAYVENT200B Sidewall Vent Termination Kit All TDY Furnaces TR 2BAYMFGH100A Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces TR 2 1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide.2 With stainless steel burners.

FU – 22 Effective date: January 1, 2008© Trane 2007

TUX2B060 — D120A XV90i Induced Draft Two Stage Upflow/Horizontal Condensing Gas Furnace with Whole House Air CleanerSpecifications: Upflow/Horizontal Condensing (Sealed Combustion - 1 or 2 Pipe Vent Option) Airflow Capacity (000) Uncrated Model In Tons Output-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 2 Stg 1 AFUE Size H W D Plant Weight

TUX2B060AFV3VA 3 56.0 36.0 93.0 2" 40 17.5 28 TR 161TUX2B080AFV3VA 3 73.0 48.0 92.5 2" 40 17.5 28 TR 171 TUX2C100AFV4VA 4 93.0 60.0 93.0 3" 40 21.0 28 TR 200 TUX2D120AFV5VA 5 112.0 66.6 92.5 3" 40 24.5 28 TR 209 * Isolated Combustion System.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit All TUX2-F Furnaces TR 1BAYLPSS210B1 Propane Conversion Kit All TUX2-F Furnaces TR 1 BAYHALT249 High Altitude Pressure Switch Kit All TUX2-F Furnaces TR 2BAYAIR30AVENTA Concentric Vent Kit All TUX2-F Furnaces TR 11BAYVENT800B Masonry Chimney Vent Kit All TUX2-F Furnaces TR 2BAYMFGH100A Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces TR 21 With stainless steel burners.

•Heavygaugealuminizedsteelheatexchanger• Insulatedblowerdoor•Gasketedblowerdoor•Twotonecolor•Multi-portIn-shotburners•Completefrontserviceaccess•Left/rightgasconnection•Slideoutblowerassembly•OptionalL.Pconversionkit•Variablespeedventor•Selectablecoolingfanoffeliminatesneedfor

BAY24X045 time delay relay•Lifetime limited primary heat exchanger

or secondary heat exchanger warranty to original owner (Residential use)•5-year limited parts warranty •Optional extended warranties

Features:•Equipped with integrated TRANE

CleanEffects™ Whole House Air Cleaner that removes up to 99% of allergens from the filtered air•Removesparticlesdownto.3micronsinsize•OutperformsHEPA,andupto100times

more effective than a standard 1" filter•SiliconNitridehotsurfaceigniterwith

adaptive heat up•VariablespeedindoorblowerwithECMmotor•Direct/Non-Directventoption•Fused24voltcontrolcircuit•Manualresetflamerolloutswitches•Powersupply115/1/60•Convertibletohorizontalonleftside•2-stagegasvalve•PVCventing-1or2pipeoption•Accessoryhook-upcapability• Integratedsolidstatecontrolwith

self-diagnostics

FU – 23 Effective date: January 1, 2008© Trane 2007

TUH2B060 — D120A XV95 Two Stage Upflow/Horizontal Variable Speed Direct/Non-Direct Vent Gas Furnace

Specifications:Upflow/Horizontal Condensing Induced Draft (Sealed Combustion -1 or 2 Pipe Vent Option) Airflow Capacity (000) Uncrated Model In Tons Output-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 2 Stg 1 AFUE Size H W D Plant Weight

TUH2B060A9V3VA 3 58.0 37.7 96.7 2,21/2,3" 40 17.5 28 TR 158TUH2B080A9V3VA 3 76.0 49.5 95.0 2,21/2,3" 40 17.5 28 TR 168 TUH2C100A9V4VA 4 95.0 61.8 95.0 21/2, 3" 40 21.0 28 TR 197 TUH2D120A9V5VA 5 114.7 74.5 95.6 3" 40 24.5 28 TR 206 * Isolated Combustion System.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit All TUH2 Furnaces TR 1BAYLPSS210B2 Propane Conversion Kit All TUH2 Furnaces TR 1 BAYRACK960A3 Filter Rack Kit-Internal All TUH2 Furnaces TR 5BAYFLTR200 Side Filter Rack - External All TUH2 Furnaces TR 5BAYFLTR203 FilterKit/HorizontalConversion TUH2B060A,080A TR 3BAYFLTR204 FilterKit/HorizontalConversion TUH2C100A TR 3BAYFLTR205 FilterKit/HorizontalConversion TUH2D120A TR 3BAYFLTR317 Filter Accessory Kit Upflow 17.5" Furnaces TR 2BAYFLTR321 Filter Accessory Kit Upflow 21" Furnaces TR 2BAYFLTR324 Filter Accessory Kit Upflow 24.5" Furnaces TR 2BAYSWT10AHALTA1 High Altitude Kit TUH2B060A TR 2BAYSWT09AHALTA1 High Altitude Kit TUH2B080A,TUH2C100A,TUH2D120A TR 2BAYAIR30AVENTA Concentric Vent Kit All TUH2 Furnaces TR 11BAYVENT200B Sidewall Vent Termination Kit All TUH2 Furnaces TR 2BAYMFGH100A Manufactured/MobileHomeKit All2PipeDirectVentFurnaces TR 2 1Optionalkitallows200ft.max.ventlengthfrom5,000-12,000feetabovesealevel.Seeinstaller'sguide.2 With stainless steel burners.3 Internal filter rack for side or bottom return air. Includes 17" cleanable filter.

Features:•Upto96.7%AFUE•VariablespeedindoorblowerwithECMmotor•SiliconNitrideIgniterwithadaptiveheatup•Direct/Non-Directventoption•Fused24voltcontrolcircuit•Manualresetburnersafetyswitches•Powersupply115/1/60•Convertibletohorizontalonleftside•2-stagegasvalve•PVCventing-1or2pipeoption•Accessoryhook-upcapability• Integratedsolidstatecontrolwith

self-diagnostics•Attractivecoloraccents•Heavygaugealuminizedsteelheat

exchanger•Multi-portIn-shotburners•Perfectfitdoorlatches• Insulatedblowerdoor

•Gasketedblowerdoor• Internalfilterrack•Standardfiltersizes•Twotonecolor•Completefrontserviceaccess•Left/rightgasconnection•Adjustablefanofftimes•Cleanablehighvelocityfilters•OptionalL.Pconversionkit•Selectablecoolingfanoffdelay eliminates need for BAY24X045

time delay kit•Lifetime limited primary heat exchanger

or secondary heat exchanger warranty to original owner (Residential use)•5-year limited parts warranty •Optional extended warranties

Ref

: 9/2

2/08

9:0

0 am

Effective date: August 7, 2008

FU – 24 Effective date: January 1, 2008© Trane 2007

•Multi-portIn-shotburners•Completefrontserviceaccess•Left/rightgasconnection•Adjustablefanofftimes•Cleanablehighvelocityfilters•OptionalL.Pconversionkit•Selectablecoolingfanoffdelayeliminates

need for BAY24X045 (time delay kit)•Lifetime limited primary heat exchanger

or secondary heat exchanger warranty to original owner (Residential use)•5-year limited parts warranty •Optional extended warranties

Features:•Minimum95%AFUE•VariablespeedblowerwithECMmotor•SiliconNitrideIgniterwithadaptiveheatup•Direct/Non-Directventoption•Fused24voltcontrolcircuit•Manualresetburnersafetyswitches•Powersupply115/1/60•Convertibletohorizontalonleftside•2-stagegasvalve•PVCventing-1or2pipeoption•Accessoryhook-upcapability•Quietinduceddraftblower• Integratedsolidstatecontrol•Attractivecoloraccents•Heavygaugealuminizedsteelheat

exchanger

TDH2B060 — D120A XV95 Two Stage Downflow/Horizontal Variable Speed Direct/Non-Direct Vent Gas Furnace

Specifications: Downflow/Horizontal Condensing Induced Draft (Sealed Combustion - 1 or 2 Pipe Vent Option) Airflow Capacity (000) Uncrated Model In Tons Output-BTUH ICS* Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 2 Stg 1 AFUE Size H W D Plant Weight

TDH2B060A9V3VA 3 57.0 37.0 95.0 2,21/2,3" 40 17.5 28 TR 160 TDH2B080A9V3VA 3 76.0 49.4 95.0 2,21/2,3" 40 17.5 28 TR 168 TDH2C100A9V4VA 4 95.0 61.8 95.0 21/2, 3" 40 21.0 28 TR 185 TDH2D120A9V5VA 5 114.0 74.0 95.0 3" 40 24.5 28 TR 206 * Isolated Combustion System.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)Controls (See Control Section)BAYLPKT210B Propane Conversion Kit All TDH2 Furnaces TR 1BAYLPSS210B2 Propane Conversion Kit All TDH2 Furnaces TR 1 BAYBASE205 Downflow Subbase All TDH2 Furnaces TR 8 BAYSWT10AHALTA1 High Altitude Kit TDH2B060A TR 2BAYSWT09AHALTA1 High Altitude Kit TDH2B080A,TDH2C100A,TDH2D120A TR 2BAYAIR30AVENTA Concentric Vent Kit All TDH2 Furnaces TR 11BAYVENT200B Sidewall Vent Termination Kit All TDH2 Furnaces TR 2BAYMFGH100A Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces TR 2 1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide.2 With stainless steel burners.

FU – 25 Effective date: January 1, 2008© Trane 2007

TUH3B060 — D120A XC95 Upflow/Horizontal Left Communicating Only Direct/Non-Direct Vent- Variable Speed Induced Draft Three-Stage Gas FurnaceSpecifications:Upflow/Horizontal Left Condensing (Sealed Combustion -1 or 2 Pipe Vent Option) Airflow Capacity (000) Uncrated Model In Tons Output-BTUH ICS1 Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 3 Stg 2 Stg 1 AFUE Size H W D Plant Weight

TUH3B060ACV3VA 3 57.0 2 23.0 95.0 2" 40 17.5 28 TR 158TUH3B080ACV3VA 3 75.0 2 30.0 95.0 2" 40 17.5 28 TR 168 TUH3C100ACV4VA 4 95.0 2 38.0 95.0 3" 40 21.0 28 TR 197 TUH3D120ACV5VA 5 114.0 2 52.0 95.0 3" 40 24.5 28 TR 206 1 Isolated Combustion System.2 Second stage output capacity is approximately equal to 65% of third stage output capacity. There is no testing protocol for this value.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)TCONT900AC43UA5 Communicating Comfort Control All TUH3 Furnaces TR 1BAYLPKT220A Propane Conversion Kit All TUH3 Furnaces TR 1BAYLPSS220A3 Propane Conversion Kit All TUH3 Furnaces TR 1 BAYRACK960A4 Filter Rack Kit-Internal All TUH3 Furnaces TR 2BAYFLTR200 Side Filter Rack - External All TUH3 Furnaces TR 5BAYFLTR203 Filter Kit/Horizontal Conversion TUH3B060,080A TR 3BAYFLTR204 Filter Kit/Horizontal Conversion TUH3C100A TR 3BAYFLTR205 Filter Kit/Horizontal Conversion TUH3D120A TR 3BAYFLTR317 Filter Accessory Kit Upflow 17.5" Furnaces TR 2BAYFLTR321 Filter Accessory Kit Upflow 21" Furnaces TR 2BAYFLTR324 Filter Accessory Kit Upflow 24.5" Furnaces TR 2BAYSWT07AHALTA High Altitude Pressure Switch Kit TUH3B060 TR 2BAYSWT08AHALTA High Altitude Pressure Switch Kit TUH3D120 TR 2BAYSWT09AHALTA High Altitude Pressure Switch Kit TUH3B080,C100 TR 2BAYAIR30AVENTA Concentric Vent Kit All TUH3 Furnaces TR 11BAYVENT200B Sidewall Vent Termination Kit All TUH3 Furnaces TR 2 3 With stainless steel burners.4 Left and bottom return only.5 Required for installation of all TUH3 furnaces.

Features:•ComfortLink™ II Communicating only

furnace design•RequirescomfortcontrolTCONT900AC43UA•Forusewithcommunicatingoutdoorproducts

or single stage - cooling only outdoor units•Plugandplayinstallation•ThreewireconnectionstoComfortControl•Variablespeedinducermotor•Storedfaultcodehistoryinmicroprocessor

non-volatile memory•Slideoutblowerassembly•VariablespeedECMmotorwithComfort-R™

•SiliconNitridehotsurfaceigniterwithadaptive heat up•Direct/Non-Directventoption•Manualresetflamerolloutswitches•Powersupply115/1/60•ConvertibletoHorizontalLeft•3-stagemodulatinggasvalve

•PVCventing-1or2pipeoption•Accessoryhook-upcapability• Integratedsolidstatecontrolwith

self-diagnostics•Attractivecoloraccents•Heavygaugealuminizedsteelheat

exchanger•Multi-portIn-shotburners• Insulatedblowerdoor•Gasketedblowerdoor•Completefrontserviceaccess•Left/rightgasconnection•OptionalL.Pconversionkit•Lifetime limited primary heat exchanger

or secondary heat exchanger warranty to original owner (Residential use)•5-year limited parts warranty •Optional extended warranties

Effective date: April 28, 2008

Ref

: 4/2

9/08

2:2

2 pm

FU – 26 Effective date: January 1, 2008© Trane 2007

TDH3B060 — D120A XC95 Downflow/Horizontal Right Communicating Only Direct/Non-Direct Vent- Variable Speed Induced Draft Three-Stage Gas Furnace

Specifications:Downflow/Horizontal Right Condensing (Sealed Combustion -1 or 2 Pipe Vent Option) Airflow Capacity (000) Uncrated Model In Tons Output-BTUH ICS*1 Flue Dimensions (in.) Mfg. ShippingNumber (Nom.) Stg 3 Stg 2 Stg 1 AFUE Size H W D Plant Weight

TDH3B060ACV3VA 3 56.0 2 22.0 92.1 2" 40 17.5 28 TR 160TDH3B080ACV3VA 3 74.0 2 30.0 95.0 2" 40 17.5 28 TR 168 TDH3C100ACV4VA 4 95.0 2 38.0 95.0 3" 40 21.0 28 TR 185 TDH3D120ACV5VA 5 109.0 2 46.0 92.1 3" 40 24.5 28 TR 206 1 Isolated Combustion System.2 Second stage output capacity is approximately equal to 65% of third stage output capacity. There is no testing protocol for this value.

Accessories:Model Mfg. Shipping Number Description Used With Plant Weight

Extended Warranties (See Extended Warranty Section)TCONT900AC43UA4 Communicating Comfort Control All TDH3 Furnaces TR 1BAYLPKT220A Propane Conversion Kit All TDH3 Furnaces TR 1BAYLPSS220A3 Propane Conversion Kit All TDH3 Furnaces TR 1 BAYBASE205 Downflow Subbase All TDH3 Furnaces TR 8BAYSWT07AHALTA High Altitude Pressure Switch Kit TDH3B060 TR 2BAYSWT08AHALTA High Altitude Pressure Switch Kit TDH3D120 TR 2BAYSWT09AHALTA High Altitude Pressure Switch Kit TDH3B080,C100 TR 2 BAYAIR30AVENTA Concentric Vent Kit All TDH3 Furnaces TR 11BAYVENT200B Sidewall Vent Termination Kit All TDH3 Furnaces TR 23 With stainless steel burners.4 Required for installation of all TDH3 furnaces.

Features:•ComfortLink™ II Communicating only

furnace design•RequirescomfortcontrolTCONT900AC43UA•Forusewithcommunicatingoutdoorproducts

or single stage - cooling only outdoor units•Plugandplayinstallation•ThreewireconnectionstoComfortControl•Variablespeedinducermotor•Storedfaultcodehistoryinmicroprocessor

non-volatile memory•Slideoutblowerassembly•VariablespeedECMmotorwithComfort-R™

•SiliconNitridehotsurfaceigniterwithadaptive heat up•Direct/Non-Directventoption•Manualresetflamerolloutswitches•Powersupply115/1/60•ConvertibletoHorizontalRight•3-stagemodulatinggasvalve

•PVCventing-1or2pipeoption•Accessoryhook-upcapability• Integratedsolidstatecontrolwith

self-diagnostics•Attractivecoloraccents•Heavygaugealuminizedsteelheat

exchanger•Multi-portIn-shotburners• Insulatedblowerdoor•Gasketedblowerdoor•Completefrontserviceaccess•Left/rightgasconnection•OptionalL.Pconversionkit•Lifetime limited primary heat exchanger

or secondary heat exchanger warranty to original owner (Residential use)•5-year limited parts warranty •Optional extended warranties

Effective date: February 13, 2008

Ref

: 2/1

3/08

2:5

3 pm

FU – 27 Effective date: January 1, 2008© Trane 2007

Special Use Furnace Accessories

Specifications: High Altitude Pressure SwitchModel Mfg. Shipping Number Description Used With Plant Weight

BAYHALT249 1 Switch TUD2,TUD-R-K,TDD-R-F,TDD2 TR 2 BAYHALT248 1 Switch TUD1/TDD1;TUE1/TDE1 TR 2

Specifications: High Altitude Pressure Switch*Model Mfg. Shipping Number Description Used With Plant Weight

BAYSWT01AHALTA 1 Switch TUC1B040,TUC1D100,TDC1B040, TR 2 TUX1B040,TUX1D100,TDX1B040 BAYSWT02AHALTA 1 Switch TUC1B060,TUX1B060 TR 2 BAYSWT03AHALTA 1 Switch TUC1B080,TUX1B080 TR 2 BAYSWT04AHALTA 1 Switch TUC1C100,TUC1D120,TDC1B080, TR 2 TDC1D120,TUX1C100,TUX1D120, TDX1B080,TDX1D120 BAYSWT05AHALTA 1 Switch TDC1C100,TDX1C100 TR 2 BAYSWT06AHALTA 1 Switch TDC1B060,TDX1B060 TR 2 BAYSWT07AHALTA 1 Switch TUH3B060,TDH3B060,TUX2B060, TR 2 TDX2B060,TUY060R,TDY060R BAYSWT08AHALTA 1 Switch TUX2B080,TUX2C100,TDX2B080,TDX2C100, TR 2 TUY120R,TDY120R,TUH2B080,TDH2B080, TUH2C100,TDH2C100,TUH2D120,TDH2D120, TUH3D120,TDH3D120 BAYSWT09AHALTA 1 Switch TUX2D120,TDX2D120,TUY080R,TDY080R, TR 2 TUY100R,TDY100R,TUH3B080,TDH3B080, TUH3C100,TDH3C100 BAYSWT10AHALTA 1 Switch TUH2B060A,TDH2B060A TR 2BAYSWT01AMALTB 1 Switch TUX1 TR 2 *NOTES: 1. All 2 stage furnace changed from two separate pressure switches to one piggy back switch.2. This change occurred with the beginning serial number 6151 in April 2006.3. The high altitude pressure switches are now piggy back type.4. The new piggy back switches are not interchangeable with the original two switch design.5. The pressure switch mounting plate is different for the piggy back switches.

Effective date: February 13, 2008

Ref

: 2/1

3/08

2:5

3 pm

FU – 28 Effective date: January 1, 2008© Trane 2007

Special Use Furnace Accessories

Specifications: Twinning KitsModel Mfg. Shipping Number Description Used With Plant Weight

BAYTWIN400A Twinning Kit TUC1 TR 2 NOTE: Variable Speed XV80 & XV90 Furnaces should not be twinned and are not approved for twinning applications.

Specifications: Optional AccessoriesModel Number Description Used With

BAY69X146 Horizontal vent cap (Noryl) TUC1/TDC1BAY69X147 Wall mount flange - 3" TUX1/TDX1, TUX1-H/TDX1-H, TUC1/TDC1BAY69X148 Wall mount flange - 2" TUX1/TDX1, TUX1-H/TDX1-H, TUC1/TDC1BAYBASE205 Downflow Subbase All Gas FurnacesBAYFLTR200 Side filter rack TUH3, TUH2, TUX2, TUX1-H, TUX1, TUD1, TUD-R, TUD2, TUC1, TUYBAYFLTR203 Filter kit horiz conversion 17.5" cabinet All Gas FurnacesBAYFLTR204 Filter kit horiz conversion 21" cabinet All Gas FurnacesBAYFLTR205 Filter kit horiz conversion 24.5" cabinet All Gas FurnacesBAYFLTR206 Filter kit All Gas Furnaces except TUY/TDYBAYFLTR3171 Filter kit for 17.5" cabinet upflow only TUH3, TUH2, TUX2/TDX2, TUD2, TUX1-H/TDX1-H, TUD1-H, TUD1, TUX1, TUC1, TUE1, TUYBAYFLTR3211 Filter kit for 21" cabinet upflow only TUH3, TUH2, TUX2/TDX2, TUD2, TUX1-H/TDX1-H, TUD1-H, TUD1, TUX1, TUC1, TUE1, TUYBAYFLTR3241 Filter kit for 24.5" cabinet upflow only TUH3, TUH2, TUX2/TDX2, TUD2, TUX1-H/TDX1-H, TUD1-H, TUD1, TUX1, TUC1, TUE1, TUYBAYLPKT210B Propane conversion kit TUH2/TDH2, TUX2/TDX2, TUD2/TDH2, TUX1-H/TDX1-H, TUC1/TDC1, TUX1/TDX1, TUY/TDYBAYLPSS210B Propane conversion kit TUH2/TDH2, TUX2/TDX2, TUD2/TDH2, TUX1-H/TDX1-H, TUC1/TDC1, TUX1/TDX1, TUY/TDYBAYLPKT220A Propane conversion kit-3 Stage TUH3/TDH3BAYLPSS220A Propane conversion kit-3 Stage TUH3/TDH3BAYMFGH100A Manufactured/Mobile home kit TUH2/TDH2, TUX2-FV, TUX2/TDX2, TUX1-H/TDX1-H, TUX1/TDX1, TUC1/TDC1, TUY/TDYBAYRACK960A34 Filter Rack Kit for upflow models only TUH3, TUH2, TUX2, TUD2, TUD1, TUX1, TUD1-H, TUC1, TUE1, TUD-RBAYAIR30AVENTA Concentric vent Kit TUH3/TDH3, TUH2/TDH2, TUX2/TDX2, TUD2-FV, for 2" 2 1/2" and 3" vent system TUX1-H/TDX1-H, TUC1/TDC1, TUX1/TDX1, TUY/TDYBAYVENT200B Sidewall vent Terminator Kit TUH3/TDH3, TUH2/TDH2, TUX2/TDX2, for Direct vent furnaces TUX1-H/TDX1-H, TUC1/TDC1, TUX1/TDX1, TUY/TDY BAYVENT800B2 Masonry chimney vent kit TUD2-FV, TUD2, TUD1, TUD1-H, TUD-R1 Each filter kit contains one (1) high velocity filter.2 Can not be used with XB80 models, TUD040C-J and TUD040-J or later models.3 Upflow only.4 Internal filter rack for side or bottom return air. Includes 17" wide filter that should be used for side return upflow installations. Other filters for bottom return furnaces, 21" and 24.5" wide upflow furnace models,

must be purchased separately.

Effective date: February 13, 2008

Ref

: 2/1

3/08

2:5

3 pm

FU – 29 Effective date: January 1, 2008© Trane 2007

Upflow and Quick Reference Horizontal Gas FurnacesSpecifications:Furnace Nom. Blower Flue Propane Outlet Return Air Model BTUH ICS* Max. Speed Motor Size Conversion Air Bottom SideNumber1 Output AFUE Airflow2 Taps H.P. (in.) Kit W D W D H DUPFLOW/HORIZONTAL — XC80 COMMUNICATING VARIABLE SPEED TWO-STAGETUD2B060ACV32A 48,000 80.0 1402 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD2B080ACV32A 64,000 80.0 1410 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD2C080ACV42A 64,000 80.0 1591 Var. Var. 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD2B100ACV32A 80,000 80.0 1251 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD2C100ACV52A 79,000 80.0 2100 Var. Var. 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD2D120ACV52A 97,000 80.0 2019 Var. Var. 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD2D140ACV52A 112,000 80.0 2075 Var. Var. 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XV80I TWO-STAGE VARIABLE SPEED WITH WHOLE HOUSE AIR CLEANER STG 2 STG 1TUD2B060AFV32A 48,000 31,200 80.0 1102 Var. 1/2 4 BAYLPKT210B 16.25 19.6 16 23.5 N/A N/ATUD2B080AFV32A 64,000 41,600 80.0 1370 Var. 1/2 4 BAYLPKT210B 16.25 19.6 16 23.5 N/A N/ATUD2C080AFV42A 64,000 41,600 80.0 1376 Var. 3/4 4 BAYLPKT210B 19.75 19.6 19.5 23.5 N/A N/ATUD2B100AFV32A 80,000 52,000 80.0 1322 Var. 1/2 4 BAYLPKT210B 16.25 19.6 16 23.5 N/A N/ATUD2D120AFV52A 97,000 62,400 80.0 1837 Var. 1 4 BAYLPKT210B 23.25 19.6 23 23.5 N/A N/AUPFLOW/HORIZONTAL — XV80 VARIABLE SPEED TWO-STAGETUD060R9V3K 48,000 80.0 1402 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080R9V3K 64,000 80.0 1410 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD080R9V4K 64,000 80.0 1591 Var. Var. 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD100R9V3K 80,000 80.0 1251 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD100R9V5K 79,000 80.0 2100 Var. Var. 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD120R9V5K 97,000 80.0 2019 Var. Var. 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD140R9V5K 112,000 80.0 2075 Var. Var. 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XL80 INDUCED DRAFT TWO-STAGETUD2A040A9242A 32,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD2A060A9362A 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD2B060A9362A 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD2B080A9362A 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD2B080A9482A 63,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD2B100A9362A 79,000 80.6 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD2C100A9482A 79,000 81.0 1669 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD2C100A9602A 80,000 80.0 1978 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD2D100A9602A 80,000 80.0 2175 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD2C120A9542A 95,000 80.0 2037 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD2D120A9602A 95,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD2D140A9602A 111,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XT80 SINGLE STAGE HIGH EFFICIENCy MOTORTUD1A040A9H21B 32,000 80.0 910 4 1/2 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1B060A9H31B 47,000 80.0 1236 4 1/2 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B080A9H31B 63,000 80.0 1296 4 1/2 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1C080A9H41B 64,000 80.0 1296 4 3/4 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD1B100A9H31B 79,000 80.0 1363 4 3/4 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1C100A9H51B 79,000 80.0 1363 4 1.0 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD1D120A9H51B 96,000 80.0 2005 4 1.0 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD1D140A9H51B 111,000 80.0 2216 4 1.0 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XR80 INDUCED DRAFT SINGLE STAGETUD1A040A9241A 32,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1A040A9301A 32,000 80.0 1092 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1A060A9241A 47,000 80.0 901 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1A060A9361A 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUD1B060A9361A 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B080A9241A 64,000 80.0 956 4 1/5 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B080A9361A 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B080A9481A 64,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1C080A9601A 64,000 80.0 2163 4 3/4 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD1B100A9361A 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUD1B100A9451A 80,000 80.0 1556 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.55TUD1C100A9481A 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD1C100A9601A 79,000 80.0 2001 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD1D100A9721A 80,000 80.0 2249 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD1C120A9541A 96,000 80.0 2037 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUD1D120A9601A 96,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUD1D140A9601A 111,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.751 Isolated Combustion System. 2 Power Supply: 115 Volts, 15 Amps, 20 Amp Fuse, 1/2" Pipe Connections. CFM @ .5" ESP with filter in place.

Effective date: October 10, 2008

Ref

: 10/

28/0

8 9:

59 a

m

FU – 30 Effective date: January 1, 2008© Trane 2007

Upflow and Quick Reference Horizontal Gas FurnacesSpecifications:Furnace Nom. Blower Flue Propane Outlet Return Air Model BTUH ICS* Max. Speed Motor Size Conversion Air Bottom SideNumber1 Output AFUE Airflow2 Taps H.P. (in.) Kit W D W D H D

Phasing Out

UPFLOW/HORIZONTAL — XB80 INDUCED DRAFT SINGLE STAGETUE1A040A9241A 31,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUE1A060A9241A 47,000 80.0 901 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUE1A060A9361A 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75TUE1B060A9361A 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUE1B080A9361A 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUE1B080A9481A 64,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUE1B100A9361A 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75TUE1C100A9481A 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.25 19.6 19.5 23.5 14.88 23.75TUE1C100A9601A 79,000 80.0 2001 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75TUE1D120A9601A 96,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75TUE1D140A9601A 111,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75UPFLOW/HORIZONTAL — XV95 VARIABLE SPEED TWO-STAGE STG 2 STG 1TUH2B060A9V3VA 58,000 37,700 96.7 1250 Var. 1/2 2,2½,3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUH2B080A9V3VA 76,000 49,500 95.0 1400 Var. 1/2 2,2½,3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUH2C100A9V4VA 95,000 61,800 95.0 1794 Var. 3/4 2½, 3 BAYLPKT210B 19.75 19.6 19.5 24 14.88 23.75TUH2D120A9V5VA 114,700 74,500 95.6 1940 Var. 1 3 BAYLPKT210B 23.25 19.6 23 24 14.88 23.75UPFLOW/HORIZONTAL — XV90I TWO-STAGE VARIABLE SPEED WITH WHOLE HOUSE AIR CLEANER STG 2 STG 1TUX2B060AFV3VA 56,000 36,000 93.0 1259 Var. 1/3 2 BAYLPKT210B 16.25 19.6 16 24 N/A N/ATUX2B080AFV3VA 73,000 48,000 92.5 1359 Var. 1/3 2 BAYLPKT210B 16.25 19.6 16 24 N/A N/ATUX2C100AFV4VA 93,000 60,000 93.0 1795 Var. 1/2 3 BAYLPKT210B 19.75 19.6 19.5 24 N/A N/ATUX2D120AFV5VA 112,000 66,600 92.5 1949 Var. 3/4 3 BAYLPKT210B 23.25 19.6 23 24 N/A N/AUPFLOW/HORIZONTAL — XV90 VARIABLE SPEED TWO-STAGE, DIRECT/NON-DIRECT VENT TUY060R9V3W 56,000 93.0 1275 Var. Var. 2–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUY080R9V3W 73,000 92.5 1400 Var. Var. 2–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUY100R9V4W 93,000 93.0 1770 Var. Var. 2½, 3 BAYLPKT210B 19.75 19.6 19 24 14.88 23.75TUY120R9V5W 112,000 92.5 1920 Var. Var. 3 BAYLPKT210B 23.25 19.6 23 24 14.88 23.75UPFLOW/HORIZONTAL — XL90 TWO STAGE, DIRECT/NON-DIRECT VENT TUX2B060A9362A 56,000 93.0 1196 4 1/3 2,2½–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUX2B080A9422A 73,000 92.5 1470 4 1/3 2,2½–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUX2C100A9482A 93,000 93.0 1746 4 1/2 2½–3 BAYLPKT210B 19.75 19.6 19 24 14.88 23.75TUX2D120A9602A 112,000 92.5 2261 4 3/4 3 BAYLPKT210B 23.25 19.6 23 24 14.88 23.75UPFLOW/HORIZONTAL — XT90 HIGH EFFICIENCy MOTOR, SINGLE STAGE, DIRECT/NON-DIRECT VENT TUX1B040A9H21B 38,000 92.1 812 4 1/2 2–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUX1B060A9H31B 56,000 92.1 1196 4 1/2 2–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUX1B080A9H31B 74,000 92.1 1470 4 1/2 2–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUX1C100A9H41B 94,000 92.1 1746 4 3/4 2–3 BAYLPKT210B 19.75 19.6 19 24 14.88 23.75TUX1D120A9H51B 113,000 92.1 2261 4 1.0 3 BAYLPKT210B 23.25 19.6 23 24 14.88 23.75UPFLOW/HORIZONTAL — XR90 SINGLE STAGE, DIRECT/NON-DIRECT VENT TUX1B040A9241A 38,000 92.1 812 4 1/5 2–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUX1B060A9241A 38,000 92.1 991 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUX1B060A9361A 56,000 92.1 1196 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUX1B080A9241A 74,000 92.1 1356 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUX1B080A9421A 74,000 92.1 1470 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUX1C080A9601A 76,000 92.1 2121 4 1/2 2–3 BAYLPKT210B 19.75 19.6 19.5 24 14.88 23.75TUX1C100A9361A 94,000 92.1 1755 4 1/2 2–3 BAYLPKT210B 19.75 19.6 19.5 24 14.88 23.75TUX1C100A9481A 94,000 92.1 1746 4 1/2 2–3 BAYLPKT210B 19.75 19.6 19.5 24 14.88 23.75TUX1D100A9601A 93,000 92.1 2165 4 1/2 2–3 BAYLPKT210B 23.25 19.6 23 24 14.88 23.75TUX1D120A9601A 113,000 92.1 2261 4 1/2 3 BAYLPKT210B 23.25 19.6 23 24 14.88 23.75UPFLOW/HORIZONTAL — XB90 SINGLE STAGE, DIRECT/NON-DIRECT VENT TUC1B040A9241A 37,000 92.1 812 3 1/5 2–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUC1B060A9361A 56,000 92.1 1196 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUC1B080A9421A 74,000 92.1 1470 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 24 14.88 23.75TUC1C100A9481A 94,000 92.1 1746 4 1/2 2–3 BAYLPKT210B 19.75 19.6 19 24 14.88 23.75TUC1D100A9601A 93,000 92.1 2165 4 1/2 2–3 BAYLPKT210B 23.25 19.6 23 24 14.88 23.75TUC1D120A9601A 113,000 92.1 2261 4 1/2 3 BAYLPKT210B 23.25 19.6 23 24 14.88 23.751 Isolated Combustion System.2 Power Supply: 115 Volts, 15 Amps, 20 Amp Fuse, 1/2" Pipe Connections. CFM @ .5" ESP with filter in place.

Ref

: 10/

28/0

8 9:

59 a

m

Effective date: October 10, 2008

FU – 31 Effective date: January 1, 2008© Trane 2007

Downflow and Quick Reference Horizontal Gas FurnacesSpecifications:Furnace Nom. Blower Flue Propane Outlet Return Model BTUH ICS* Max. Speed Motor Size Conversion Downflow Air AirNumber1 Output AFUE Airflow2 Taps H.P. (in.) Kit Subbase W D H DDOWNFLOW/HORIZONTAL — XC80 COMMUNICATING VARIABLE SPEED TWO STAGETDD2B060ACV32A 48,000 80.0 1360 Var. Var. 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDD2B080ACV32A 63,000 80.0 1315 Var. Var. 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDD2C100ACV52A 81,000 80.0 2015 Var. Var. 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.63TDD2D120ACV52A 95,000 80.0 2215 Var. Var. 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.63DOWNFLOW/HORIZONTAL — XV80 VARIABLE SPEED TWO STAGETDD060R9V3F 48,000 80.0 1360 Var. Var. 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDD080R9V3F 63,000 80.0 1315 Var. Var. 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDD100R9V5F 81,000 80.0 2015 Var. Var. 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.63TDD120R9V5F 95,000 80.0 2215 Var. Var. 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.63DOWNFLOW/HORIZONTAL — XL80 INDUCED DRAFT TWO STAGE TDD2A040A9242A 32,000 80.0 960 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.63TDD2A060A9362A 47,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.63TDD2B060A9362A 47,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDD2B080A9362A 64,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDD2B100A9452A 79,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDD2C100A9482A 79,000 80.0 1740 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.63TDD2C100A9602A 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.63TDD2D120A9602A 94,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.63TDD2D140A9602A 113,000 80.0 2133 4 3/4 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.63DOWNFLOW/HORIZONTAL — XT80 SINGLE STAGE HIGH EFFICIENCy MOTORTDD1B060A9H31B 48,000 80.0 1282 4 1/2 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDD1B080A9H31B 64,000 80.0 1369 4 1/2 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDD1C100A9H51B 81,000 80.0 1929 4 1.0 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.63TDD1D120A9H51B 96,000 80.0 2049 4 1.0 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.63DOWNFLOW/HORIZONTAL — XR80 INDUCED DRAFT SINGLE STAGETDD1A040A9241A 31,000 78.0 920 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.63TDD1A060A9241A 48,000 80.0 1001 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.63TDD1A060A9361A 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.63TDD1B060A9361A 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDD1B080A9361A 64,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDD1B080A9451A 64,000 80.0 1575 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDD1B100A9451A 80,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDD1C100A9481A 80,000 80.0 1740 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.63TDD1C100A9541A 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.63TDD1C120A9541A 96,000 80.0 1918 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.63TDD1D120A9601A 96,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.63TDD1D140A9601A 113,000 80.0 2133 4 3/4 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.63DOWNFLOW/HORIZONTAL — XB80 INDUCED DRAFT SINGLE STAGETDE1A060A9361A 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.63TDE1B060A9361A 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDE1B080A9451A 64,000 80.0 1575 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDE1B100A9451A 80,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDE1C100A9601A 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.63TDE1D120A9601A 96,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.631 Isolated Combustion System.2 CFM @ .5 inches ESP with filter in place.

Effective date: October 10, 2008

Ref

: 10/

28/0

8 9:

59 a

m

FU – 32 Effective date: January 1, 2008© Trane 2007

Downflow and Quick Reference Horizontal Gas FurnacesSpecifications:Furnace Nom. Blower Flue Propane Outlet Return Model BTUH ICS* Max. Speed Motor Size Conversion Downflow Air AirNumber1 Output AFUE Airflow2 Taps H.P. (in.) Kit Subbase W D H D

Phasing Out

DOWNFLOW/HORIZONTAL — XV95 VARIABLE SPEED TWO-STAGE STG 2 STG 1TDH2B060A9V3VA 57,000 37,000 95.0 1325 Var. 1/2 2,21/2,3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDH2B080A9V3VA 76,000 49,400 95.0 1220 Var. 1/2 2,21/2,3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDH2C100A9V4VA 95,000 61,800 95.0 1813 Var. 3/4 21/2, 3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.63TDH2D120A9V5VA 114,000 74,000 95.0 1900 Var. 1 3 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.63DOWNFLOW/HORIZONTAL — XV90 VARIABLE SPEED TWO-STAGE, DIRECT/NON-DIRECT VENTTDY060R9V3W 56,000 92.0 1350 Var. Var. 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDY080R9V3W 74,000 92.5 1210 Var. Var. 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDY100R9V4W 94,000 93.0 1800 Var. Var. 2,21/2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.63TDY120R9V5W 112,000 92.5 1900 Var. Var. 3 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.63DOWNFLOW/HORIZONTAL — XL90 TWO STAGE, DIRECT/NON-DIRECT VENTTDX2B060A9362A 55,000 92.0 1209 4 1/3 2,21/2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDX2B080A9422A 74,000 92.5 1323 4 1/2 2,21/2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDX2C100A9482A 93,000 93.0 1614 4 1/2 21/2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.63TDX2D120A9602A 111,000 92.5 1939 4 3/4 3 BAYLPKT210B BAYBASE205 23 19.6 23.75 19.63DOWNFLOW/HORIZONTAL — XT90 HIGH EFFICIENCy MOTOR, SINGLE STAGE, DIRECT/NON-DIRECT VENTTDX1B040A9H31B 38,000 91.0 807 4 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDX1B060A9H31B 56,000 91.0 1209 4 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDX1B080A9H31B 74,000 91.0 1323 4 3/4 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDX1C100A9H41B 94,000 91.0 1614 4 3/4 2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.63TDX1D120A9H51B 112,000 91.0 1939 4 1.0 3 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.63DOWNFLOW/HORIZONTAL — XR90 SINGLE STAGE, DIRECT/NON-DIRECT VENTTDX1B040A9241A 38,000 91.0 807 4 1/5 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDX1B060A9361A 56,000 91.0 1209 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDX1B080A9421A 74,000 91.0 1323 3 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.63TDX1C100A9481A 94,000 91.0 1614 3 1/2 2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.63TDX1D120A9601A 112,000 91.0 1939 3 1/2 3 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.63DOWNFLOW/HORIZONTAL — XB90 SINGLE STAGE, DIRECT/NON-DIRECT VENTTDC1B040A9241A 38,000 91.0 807 4 1/5 2–3 BAYLPKT210B BAYBASE205 16 19 16.25 19.63TDC1B060A9361A 56,000 91.0 1082 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19 16.25 19.63TDC1B080A9421A 74,000 91.0 1323 3 1/2 2–3 BAYLPKT210B BAYBASE205 16 19 16.25 19.63TDC1C100A9481A 93,000 91.0 1614 3 1/2 2–3 BAYLPKT210B BAYBASE205 19.5 19 19.75 19.63TDC1D120A9601A 112,000 91.0 1939 3 1/2 3 BAYLPKT210B BAYBASE205 23.0 19 23.25 19.63

1 Isolated Combustion System.2 CFM @ .5 inches ESP with filter in place.

Effective date: May 23, 2008

Ref

: 6/1

9/08

12:

01 p

m

FU – 33 Effective date: January 1, 2008© Trane 2007

Furnace ConfigurationHV = High Boy Vertical Flue LF = Low Boy Front Flue (Vertical)LR = Low Boy Rear FlueDF = Downflow/Horizontal Front Flue

Heating Stages

Cabinet WidthM = 22 1/4"

Heating Output MBTUH087 = 87,000BTUH

Major Desigh Change

Power Supply1 = 115 v/1 ph/60hz

Nominal CapacityStandard Variable Speed36 = 3 Tons V3 = 3 Tons48 = 4 Tons V4 = 4 Tons

EfficiencyS = 80% + AFUE

Major Design Change

Service Digit

T H V 1 M 0 8 7 A 9 3 6 S A A

Oil Furnace Nomenclature

FU – 34 Effective date: January 1, 2008© Trane 2007

Variable Speed High Efficiency Oil Furnaces

Specifications: Airflow Nominal Uncrated Model In Tons Cap-BTUH ICS Flue Dimensions(In.) Mfg. Shipping Number (Nom.) *Htg Output AFUE Size H W D Plant Weight

THV1M087A9V3SA 3 87,000 82.9 6" 58.0 22.25 31.0 TR 260THV1M087A9V5SA 5 87,000 82.6 6" 58.0 22.25 31.0 TR 260TLF1M087A9V3SA 3 87,000 82.9 6" 41.5 22.25 47.0 TR 300TLF1M087A9V5SA 5 87,000 82.7 6" 41.5 22.25 47.0 TR 300TLR1M087A9V3SA 3 87,000 85.0 6" 41.5 22.25 47.0 TR 300TLR1M087A9V5SA 5 87,000 82.4 6" 41.5 22.25 47.0 TR 300TDF1M087A9V3SA 3 87,000 84.8 6" 22.25 61.25 22.25 TR 280TDF1M087A9V5SA 5 87,000 82.6 6" 22.25 61.25 22.25 TR 280* Other input/output capacities are avaliable by changing the burner nozzle. See installer's guide for details.

Accessories: Mfg. Shipping Model Description Used With Plant Weight

BAYSUB10ABASEA Downflow Subbase TDF1M087A9V3, 9V5SAA TR 22BAYTRM10AVENTA Top Panel & Trim Ring THV1M087A9V3, 9V5SAA TR 1

Features:•Upto85%AnnualFuelUtilizationEfficiency

(AFUE)•13gaugehotrolledsteelwraparoundheat

exchanger for durability•BeckettFlameRetentionBurneroperates

cleanly and quietly•Burnerfeaturesincludeprimarycontrolwith

interrupted ignition for reliability, pre-purge and clean cutoff solenoid valve for smooth ignition•Burnerandcontrolsfactorywired•Dualcleanoutportsforquickaccessand

easy cleaning• Insulatedblowercompartment•Variablespeedblowermotor• Insulatedblowercompartment

•Slideoutblowerassemblyforquickcleaningand service accessibility •Filterrackwithcleanablefilter(Highboy&

Lowboy Models) except Downflow/Horizontal•Preformedceramicfiber

combustion chamber for higher efficiencies and more complete combustion•40VAcontroltransformerforaddoncooling•Heavygauge,powderpaintedsteelcabinet•Recesseddoorhandlesforeasyremovalof

highboy & lowboy furnace doors•Lowboymodelsavailablewithfrontorrear

flue option•Highboymodelswithtoporrightsideventing

•Downflow/Horizontalmodelfieldconvertiblefrom Downflow to right or left horizontal•6”LeftandRightsidefreshairknockouts

– Highboy and Lowboy Models•Barometricdraftregulatorincluded•5-year limited parts warranty•Limited lifetime heat exchanger warranty

TDF - Downflow/Horizontal

TLF - Lowboy Front Flue (TLR not shown)

THV - Highboy Vertical

THV, TLF, TLR, TDF Vertical HighboyLowboy Front FlueLowboy Rear FlueDownflow/Horizontal

Effective date: March 17, 2008

Ref

: 2/1

8/08

1:1

9 pm

FU – 35 Effective date: January 1, 2008© Trane 2007

High Efficiency Oil Furnaces Specifications: Airflow Nominal Uncrated Model In Tons Cap-BTUH ICS Flue Dimensions(In.) Mfg. Shipping Number (Nom.) Htg Output AFUE Size H W D Plant Weight

THV1M087A936SA 3 87,000 82.9 6" 58.0 22.25 31.0 TR 260THV1M087A948SA 4 87,000 82.6 6" 58.0 22.25 31.0 TR 260TLF1M087A936SA 3 87,000 82.9 6" 41.5 22.25 47.0 TR 300TLF1M087A948SA 4 87,000 82.7 6" 41.5 22.25 47.0 TR 300TLR1M087A936SA 3 87,000 85.0 6" 41.5 22.25 47.0 TR 300TLR1M087A948SA 4 87,000 82.4 6" 41.5 22.25 47.0 TR 300TDF1M087A936SA 3 87,000 84.8 6" 22.25 61.25 22.25 TR 280TDF1M087A948SA 4 87,000 82.6 6" 22.25 61.25 22.25 TR 280 Accessories: Mfg. Shipping Model Description Used With Plant Weight

BAYSUB10ABASEA Downflow Subbase TDF1M087A936, 948SAA TR 22BAYTRM10AVENTA Top Panel & Trim Ring THV1M087A936, 948SAA TR 1

Features:•Upto85%AnnualFuelUtilizationEfficiency

(AFUE)•13gaugehotrolledsteelwraparoundheat

exchanger for durability•BeckettFlameRetentionBurneroperates

cleanly and quietly•Burnerfeaturesincludeprimarycontrolwith

interrupted ignition for reliability, valve on delay and clean cutoff solenoid valve for smooth ignition•Burnerandcontrolsfactorywired•Dualcleanoutportsforquickaccessand

easy cleaning•Directdrive,permanentlylubricated,4speed

blower motor• Insulatedblowercompartment

•Slideoutblowerassemblyforquickcleaningand service accessibility •Filterrackwithcleanablefilter(Highboy&

Lowboy Models) except Downflow/Horizontal•Preformedceramicfiber

combustion chamber for higher efficiencies and more complete combustion•40VAcontroltransformerforaddoncooling•Heavygauge,powderpaintedsteelcabinet•Recesseddoorhandlesforeasyremovalof

highboy & lowboy furnace doors•Lowboymodelsavailablewithfrontorrear

flue option•Highboymodelswithtoporrightsideventing

•Downflow/Horizontalmodelfield convertible from Downflow to right or left horizontal•6”LeftandRightsidefreshairknockouts

– Highboy and Lowboy Models•Barometricdraftregulatorincluded•5-year limited parts warranty•Lifetime heat exchanger warranty

TDF - Downflow/Horizontal

TLF - Lowboy Front Flue (TLR not shown)

THV - Highboy Vertical

THV, TLR, TLF, TDF Vertical HighboyLowboy Front FlueLowboy Rear FlueDownflow/Horizontal

Effective date: March 17, 2008

Ref

: 2/1

8/08

1:1

9 pm

FU – 36 Effective date: January 1, 2008© Trane 2007

FuelG = Gas P = Oil

Efficiency - FeatureB = 80% Natural Draft, Electronic IgnitionF = 80% Power Burner, Electronic IgnitionR = 80% Direct Vent Electronic Ignition

Boiler TypeW = Water

Mount/Heat ExchangerF = Floor Standing - Cast IronW = Wall - Aluminum

CapacityNominal Heating Input MBTUH (000's)

Major Design Change

Voltage9 = 115 v/1 ph/60hz

Number of Cast Iron Sections

Heating Stages (Gas or Oil)A = Single StageM = Modulating

Vent Devises0 = NoneB = Barometric Draft Regultor (Oil-Fired Models)V = Automatic Vent Damper (Natural Draft, Gas-Fired Models)

Minor Design Change

Service Digit

T G B W F 0 9 0 A 9 3 A V A A

Gas and Oil Boiler Nomenclature

FU – 37 Effective date: January 1, 2008© Trane 2007

TGBWF090 — 215A Natural Draft Gas Fired Cast Iron Water Boiler

Specifications: DOE # HtModel Input Capacity Net IBR Flue Exch. Dimensions (in.) Mfg. ShippingNumber (BTUH) (BTUH) (BTUH) AFUE Size Sec. H W D Plant Weight

TGBWF090A93AVA1 90,000 76,000 66,000 83.6 5" 3 33.5 15.8 24.2 TR 276TGBWF130A94AVA1 130,000 111,000 96,000 83.5 6" 4 33.5 19.7 24.2 TR 345TGBWF173A95AVA1 173,000 145,000 126,000 83.4 6" 5 33.5 19.7 24.2 TR 406TGBWF215A96AVA1 215,000 180,000 156,000 83.3 7" 6 33.5 23.6 24.2 TR 468

Accessories:Model Mfg. Shipping Number Description Plant Weight

Extended Warranties (See Extended Warranty Section)BAYLPK01AWBLRA Natural Gas to Liquid Propane (LP) Conversion Kit TR 1 BAYLMT10AMRSTA Manual Reset High Limit Temperature Control TR 1 BAYTRM10AVTVPA2 Trim Kit Includes 4.4 Gallon Expansion Tank, Fill Valve, TR 18 Backflow Preventer (1" NPT) and Air Eliminator BAYTRM20AVTVPA2 Trim Kit Includes 4.4 Gallon Expansion Tank, Fill Valve, TR 18 Backflow Preventer (1-1/4" NPT) and Air Eliminator BAYEXP30ATANKA2 4.4 Gallon Expansion Tank TR 41 Factory Installed Natural Gas Orifices.2 Honeywell brand.

Features:•Powersupply115/1/60• Intermittentelectronicignition•Builtindrafthood •Automaticventdamperincluded•Factoryinstalledboilerdrain•Rearutilities-easyconnections•Factoryinstalledsupplyandreturnpipe

nipples - NPT both ends •Simplifiedfieldconnectionstoterminalstrip•Controlsandcomponentsenclosedinjacket•Powderpaintedpolyslategrayjacket•Tool-lesstopandfrontaccesspanelremoval•Controlpanelmountedpowerdisconnect

switch •Tubularstainlesssteelburners

•Castironsectionsassembledwithsteelpushnipples•Fieldconfigurablecirculator/burneroperation•Factoryinstalledtemperature

pressure gauge•Factoryinstalledadjustablewaterthermostat•Factoryinstalledautomaticresettinghighlimit•Factoryinstalled30PSIASMEreliefvalve• Insulatedheatexchanger•ConvertibletoLPwithorificekit•Optionalmanualresethighlimitaccessory

(installation required)•Annualfuelefficiencyupto83.6%

•5-year limited parts warranty•Limited lifetime heat exchanger warranty•Optional extended warranties

FU – 38 Effective date: January 1, 2008© Trane 2007

TGRWF130A Direct Vent Gas Fired Cast Iron Water Boiler

Specifications: DOE # HtModel Input Capacity Net IBR Flue Exch. Dimensions (in.) Mfg. ShippingNumber (BTUH) (BTUH) (BTUH) AFUE Size Sec. H W D Plant Weight

TGRWF130A94A0A12 130,000 110,000 96,000 84.3 3" 4 33.46 19.69 24.21 TR 360

Accessories:Model Mfg. Shipping Number Description Plant Weight

Extended Warranties (See Extended Warranty Section)BAYLPK01AWBLRA Natural Gas to Liquid Propane (LP) Conversion Kit TR 1 BAYLMT10AMRSTA Manual Reset High Limit Temperature Control TR 1 BAYTRM10AVTVPA3 Trim Kit Includes 4.4 Gallon Expansion Tank, Fill Valve, TR 18 Backflow Preventer (1" NPT) and Air Eliminator BAYTRM20AVTVPA3 Trim Kit Includes 4.4 Gallon Expansion Tank, Fill Valve, TR 18 Backflow Preventer (1-1/4" NPT) and Air Eliminator BAYEXP30ATANKA3 4.4 Gallon Expansion Tank TR 41 Factory Installed Natural Gas Orifice.2 Direct vent model requires field supplied 29-4C stainless steel vent material. 3" E-Z Vent adapter included with boiler. 3 Honeywell brand.

Features:•Powersupply115/1/60• Intermittentelectronicignition•Twopipeventsystem(upto130equivalent

feet of 3" pipe)•Factoryinstalledboilerdrain•Rearutilities-easyconnections•Factoryinstalledsupplyandreturnpipe

nipples - NPT both ends•Supplypipenipplewithteeforpressurerelief

valve - NPT both ends (installation required)•Simplifiedfieldconnectionstoterminalstrip•Controlsandcomponentsenclosedinjacket•PowderpaintedpolyslategrayJacket•Tool-lesstopandfrontaccesspanelremoval•Tubularstainlesssteelburners•Castironsectionsassembledwithsteelpush

nipples

•Fieldconfigurablecirculator/burneroperation•Factoryinstalledtemperature

pressure gauge•Factoryinstalledadjustablewaterthermostat•Factoryinstalledautomaticresettinghighlimit•30PSIASMEreliefvalveincluded

(installation required)•ConvertibletoLPwithorfice• Insulatedheatexchanger•Optionalmanualresethighlimitaccessory

(installation required)•Annualfuelefficiencyupto84.3%•5-year limited parts warranty•Limited lifetime heat exchanger warranty•Optional extended warranties

FU – 39 Effective date: January 1, 2008© Trane 2007

TPFWF071 — 286A Oil Fired Boiler 3 Pass Cast Iron Heat Exchanger

Specifications: DOE # HtModel Input Capacity Net IBR Flue Exch. Dimensions (in.) Mfg. ShippingNumber GPH (BTUH) (BTUH) (BTUH) AFUE Size Sec. H W D Plant Weight

TPFWF071A93ABA1 0.5 71,000 61,000 53,000 85.5 5" 3 33.46 19.68 17.0 TR 294 TPFWF099A94ABA1 0.7 99,000 86,000 75,000 85.7 5" 4 33.46 19.68 20.9 TR 360 TPFWF132A95ABA1 0.9 132,000 115,000 100,000 85.9 5" 5 33.46 19.68 24.9 TR 429 TPFWF164A96ABA1 1.2 164,000 143,000 125,000 86.1 5" 6 33.46 19.68 28.8 TR 497 TPFWF201A97ABA1 1.4 201,000 176,000 153,000 86.3 5" 7 33.46 19.68 32.8 TR 565 TPFWF242A98ABA1 1.7 242,000 212,000 185,000 86.5 5" 8 33.46 19.68 36.7 TR 632 TPFWF286A99ABA1 2.0 286,000 252,000 219,000 86.7 5" 9 33.46 19.68 40.6 TR 698

Burners:Riello Nozzles Used Mfg. Shipping Oil Burners Description Inculded1 With Plant Weight

BAYRAF03ABURNA2 Burner-Chimney Vent 2 TPFWF071,099 TR 25 BAYRAF05ABURNA2 Burner-Chimney Vent 3 TPFWF132,164,201 TR 25 BAYRAF10ABURNA2 Burner-Chimney Vent 2 TPFWF242,286 TR 30 BAYRBF03ABURNA2 Burner-Chimney Vent or Direct Vent 2 TPFWF071,099 TR 30 BAYRBF05ABURNA2 Burner-Chimney Vent or Direct Vent 3 TPFWF132,164,201 TR 30

Accessories:Model Mfg. Shipping Number Description Plant Weight

Extended Warranties (See Extended Warranty Section)BAYLMT10AMRSTA Manual reset high limit temperature control TR 1 BAYTRM10AVTVPA3 Trim Kit Includes 4.4 Gallon Expansion Tank, Fill Valve, TR 18 Backflow Preventer (1" NPT) and Air Eliminator BAYTRM20AVTVPA3 Trim Kit Includes 4.4 Gallon Expansion Tank, Fill Valve, TR 18 Backflow Preventer (1-1/4" NPT) and Air EliminatorBAYEXP30ATANKA3 4.4 Gallon Expansion Tank TR 4BAYDVK10ARELLA45 Direct Vent Kit for BF Oil Burners - 10 foot TR 13BAYDVK15ARELLA45 Direct Vent Kit for BF Oil Burners - 15 foot TR 17BAYVTS10AFAFVA6 Horizontal Vent Terminal, Standard, Combination Fresh Air Intake & Flue Vent TR 14BAYDVK10AADPTA Combustion Air Intake Adapter, 3" to 4" Used with BF Oil Burner TR 21 See Installers Guide for approved boiler-burner model combinations.2 Smallest nozzle is factory installed.3 Honeywell brand.4 Includes pipe, adapters, clamps and 10 oz. sealant.5 Does not include vent terminal.6 Complete direct vent system requires installation of 10 or 15 ft vent kit model BAYDVK10ARELLA or BAYDVK15ARELLA and vent terminal model BAYVTS10AFAFVA.

Features:•Powersupply115/1/60•ExceedEnergyStar® minimum efficiency•Efficienciesup86.7%AFUE•Convertibleleft/rightswingdoor•Rearutilities-easyconnections•Simplifiedfieldconnectionstoterminalstrip•Controlsandcomponentsenclosedinjacket•TaperedNPTpipethreads•Powderpaintedpolyslategrayjacket•Castironsectionsassembledwithpush

nipples

•Fieldconfigurablecirculator/burneroperation•Factoryinstalledtemperaturepressuregauge•Factoryinstalledadjustablewaterthermostat•Factoryinstalledautomaticresettinghighlimit•30PSIASMEreliefvavleandteeincluded

(installation required) •3"heatexchangerinsulation•Optionalmanualresethighlimitaccessory

(installation required) •Oilburnerwithfactoryinstalledrelaykitand

electronic air shutter•Oilburnersoundenclosurematchesboilerjacketcolor

•5-year limited parts warranty•Limited lifetime heat exchanger warranty•Optional extended warranties

Ref

: 1/1

4/09

7:5

5 pm

Effective date:January 7, 2009