BS-240 and BS-230 Clinical Chemistry Analyzer

30
BS-240 and BS-230 Clinical Chemistry Analyzer Harry Hu

Transcript of BS-240 and BS-230 Clinical Chemistry Analyzer

BS-240 and BS-230 Clinical ChemistryAnalyzerHarry Hu

We have something new…

When we talking about a new clinical chemistry analyzer with 200 T/H throughput,what you are expecting for?

Not enough sample or reagentpositions?

© 2012 MindrayConfidential

4

Up to 80 Sample positions +

Up to 80 Reagent positions

40 Sample positions +

80 Reagent positions

40 Sample positions +

40 Reagent positions

Getting tired with Cuvettesloading? Too much waterconsumption? Facing a carryoverproblem?

4 stages 8 steps washingstationWater consumption:≤4L/HCarryover < 1ppm

Redefined Washingstation

How to reduce lab cost?

100μlMinimum Reaction Volume

All Mindray items

α-HBDHCHE Fe

TBA LDL-CHDL-C

Glu-G

MALB

LDHRF CysC

β2-mG

CREA-S

HbA1C

ASO

ALT LP(a)

UA

CO2

γ-GT C3

IgA

IgG

CREA-J HS-CRP ASTIgE

Reagent consumption < BS-120/200/200E

TP G6PD FER

ALP

CK

CK-MB FUN

α-AMY

CRP

ADA

5′-NT

ALB

TC

TG

Ca

Mg

P

LIP

PA

Glu-H

UREAApoB

TRF

ACE IgM

D-Bil

D-Bil

RBP

C4

100 μl minimum reaction volume means?

Less reaction volume

100ul minimumreaction volume30% less thanBS-200/200E

Reusable Cuvette

5 cuvette in onesegment40 cuvette in one batch

Less ConsumablesLess Reagent Cost

Spent too much onapplication training?

Low End

BS-480

Medium

BS-800M

BS-2000M

High End

BS-600

BS-800

<200T/H

<600T/H

<2000 T/H

One software platform

BS-240BS-230

BS-200/200Esoftware

BS-230/240software

New Functions47

Close System

One Keyparameter

import

Step by stepmaintenance guide

Twin Test

Reflex function

Auto QC

Sample Info. autodownload from LIS

Reagent testmanaging

© 2012 MindrayConfidential15

You may face a problemabout lab room, then youneed…

-37%Smaller than BS-200E

Compact Size with practical functions

Internal Barcodereader (Optional)

Compact Size with practical functions

Waterfall probeclean (likeBS-2000M)Carryover<0.05%

Compact Size with practical functions

ISE reagent packageloaded at right side(more convenience)

© 2012 Mindray Confidential20

Compact Size with practical functions

Lamp is placedclose to operator

One More Thing…

CONS

PROS

•••

Need special equipmentHigh costSlow speed, the moreaccurate, the more slowEasily interfered byhemoglobin variants

Latex particles easilycontaminates testing system Easily interfered by Hbvariant Easily interfered byhemolysis, chyle andjaundice

Applied onchemistry analyzerLess cost andquick test

Pretreatment

•••

Applied on chemistry analyzerLess cost and quick testNo interference fromhemoglobin variantsNo contamination from latexparticles

VariantidentificationGold Standard

HPLC Method Turbidimetry Method Enzymatic Method

VS

Specialist HbA1cAnalyzer

Why BS-240 is the best choice for HbA1ctesting?

Convenience : No need for pretreatment

Trustable: New generation method which avoid variant interference

1.2.3.

Low cost:Low cost for equipmentLow cost for reagent and consumablesNot only HbA1c, other high value items could be tested on BS-240 aswell to share the cost

A appropriate way to step into central labs

Whole Blood Testing

Flexible sample/reagentpositions

100μl minimum reactionvolume

Compact size

Auto-washing function

New software platform withmore functions

1

2

3

4

5

6

BS-230 BS-240Washing Station N Y

Reusable Cuvette N (disposable) Y

Probe Different

Whole BloodTesting function N Y

Throughput Same

Dimension Same

Software Same

BS-240 BS-200E BS-230 BS-200 BS-120 CS-T240 Chemray 240

LWC200E

Urit8021A

Throughput 200/400 200/330 200/400 200/330 100/250 240 tests 240 225 200

ISE Y Y Y Y Y N N Y N

SamplePosition

Up to80(40) 40 Up to

80(40) 40 Up to 3567

positionsshared bysamples

andreagents

40 60 45

ReagentPosition

Up to80(80) 40 Up to

80(80) 40 Up to 34 40 60 60

ReactionCuvette

40reusablecuvettes

80reusablecuvettes

40disposable cuvettes

80disposable cuvettes

40disposab

lecuvettes

120reusablecuvettes

81reusablecuvettes

81reusablecuvettes

120reusablecuvettes

SampleVolume

2μL~45μL,

0.1μL

2-45ul,step by

0.1ul

2μL~45μL,

0.1μL

2-45ul,step by

0.1ul

3-45ul,step by

0.5ul

3~35ul,step by

0.1ul

3-45ul,step by

0.5ul

2~30uL,step by

0.1ul

2~100ul,0.1ul

ReagentVolume

10μL~250μL,

0.5μL

10-350ul,step by

1ul

10μL~250μL,

0.5μL

10-450 l,step by

1ul

180-450ul, step by

1ul

10~350ul,step by 1ul

30-450 l,step by

1ul

20~300ul,step by

1ul

10~500uL, 0.5uL

Mini-ReactionVolume

100μL〜360μL

150-360ul

100μL〜360μL

150-500ul

180-500ul 150ul 180-500

ul 150ul 180uL

Wavelength 8 12 8 8 8 12 8 8 10

Whole Blood Y N N N N N N N N

Launching

First Show for BS-240:

24th January, Arab Health, Dubai

Launch Time(with CE, FSC, etc.):

31st March

© 2012 Mindray Confidential30