BS-240 and BS-230 Clinical Chemistry Analyzer
-
Upload
khangminh22 -
Category
Documents
-
view
2 -
download
0
Transcript of BS-240 and BS-230 Clinical Chemistry Analyzer
We have something new…
When we talking about a new clinical chemistry analyzer with 200 T/H throughput,what you are expecting for?
© 2012 MindrayConfidential
4
Up to 80 Sample positions +
Up to 80 Reagent positions
40 Sample positions +
80 Reagent positions
40 Sample positions +
40 Reagent positions
All Mindray items
α-HBDHCHE Fe
TBA LDL-CHDL-C
Glu-G
MALB
LDHRF CysC
β2-mG
CREA-S
HbA1C
ASO
ALT LP(a)
UA
CO2
γ-GT C3
IgA
IgG
CREA-J HS-CRP ASTIgE
Reagent consumption < BS-120/200/200E
TP G6PD FER
ALP
CK
CK-MB FUN
α-AMY
CRP
ADA
5′-NT
ALB
TC
TG
Ca
Mg
P
LIP
PA
Glu-H
UREAApoB
TRF
ACE IgM
D-Bil
D-Bil
RBP
C4
100 μl minimum reaction volume means?
Less reaction volume
100ul minimumreaction volume30% less thanBS-200/200E
Reusable Cuvette
5 cuvette in onesegment40 cuvette in one batch
Less ConsumablesLess Reagent Cost
Low End
BS-480
Medium
BS-800M
BS-2000M
High End
BS-600
BS-800
<200T/H
<600T/H
<2000 T/H
One software platform
BS-240BS-230
New Functions47
Close System
One Keyparameter
import
Step by stepmaintenance guide
Twin Test
Reflex function
Auto QC
Sample Info. autodownload from LIS
Reagent testmanaging
CONS
PROS
•••
•
Need special equipmentHigh costSlow speed, the moreaccurate, the more slowEasily interfered byhemoglobin variants
•
•
•
Latex particles easilycontaminates testing system Easily interfered by Hbvariant Easily interfered byhemolysis, chyle andjaundice
•
•
Applied onchemistry analyzerLess cost andquick test
Pretreatment
•••
•
Applied on chemistry analyzerLess cost and quick testNo interference fromhemoglobin variantsNo contamination from latexparticles
•
•
VariantidentificationGold Standard
HPLC Method Turbidimetry Method Enzymatic Method
Why BS-240 is the best choice for HbA1ctesting?
Convenience : No need for pretreatment
Trustable: New generation method which avoid variant interference
1.2.3.
Low cost:Low cost for equipmentLow cost for reagent and consumablesNot only HbA1c, other high value items could be tested on BS-240 aswell to share the cost
A appropriate way to step into central labs
Whole Blood Testing
Flexible sample/reagentpositions
100μl minimum reactionvolume
Compact size
Auto-washing function
New software platform withmore functions
1
2
3
4
5
6
BS-230 BS-240Washing Station N Y
Reusable Cuvette N (disposable) Y
Probe Different
Whole BloodTesting function N Y
Throughput Same
Dimension Same
Software Same
BS-240 BS-200E BS-230 BS-200 BS-120 CS-T240 Chemray 240
LWC200E
Urit8021A
Throughput 200/400 200/330 200/400 200/330 100/250 240 tests 240 225 200
ISE Y Y Y Y Y N N Y N
SamplePosition
Up to80(40) 40 Up to
80(40) 40 Up to 3567
positionsshared bysamples
andreagents
40 60 45
ReagentPosition
Up to80(80) 40 Up to
80(80) 40 Up to 34 40 60 60
ReactionCuvette
40reusablecuvettes
80reusablecuvettes
40disposable cuvettes
80disposable cuvettes
40disposab
lecuvettes
120reusablecuvettes
81reusablecuvettes
81reusablecuvettes
120reusablecuvettes
SampleVolume
2μL~45μL,
0.1μL
2-45ul,step by
0.1ul
2μL~45μL,
0.1μL
2-45ul,step by
0.1ul
3-45ul,step by
0.5ul
3~35ul,step by
0.1ul
3-45ul,step by
0.5ul
2~30uL,step by
0.1ul
2~100ul,0.1ul
ReagentVolume
10μL~250μL,
0.5μL
10-350ul,step by
1ul
10μL~250μL,
0.5μL
10-450 l,step by
1ul
180-450ul, step by
1ul
10~350ul,step by 1ul
30-450 l,step by
1ul
20~300ul,step by
1ul
10~500uL, 0.5uL
Mini-ReactionVolume
100μL〜360μL
150-360ul
100μL〜360μL
150-500ul
180-500ul 150ul 180-500
ul 150ul 180uL
Wavelength 8 12 8 8 8 12 8 8 10
Whole Blood Y N N N N N N N N
Launching
First Show for BS-240:
24th January, Arab Health, Dubai
Launch Time(with CE, FSC, etc.):
31st March