1675 LambdaUnite® MultiService Switch (MSS), Release ...
-
Upload
khangminh22 -
Category
Documents
-
view
4 -
download
0
Transcript of 1675 LambdaUnite® MultiService Switch (MSS), Release ...
Alcatel-Lucent - ProprietaryThis document contains proprietary information of
Alcatel-Lucent and is not to be disclosed or used except inaccordance with applicable agreements
Copyright © 2012 Alcatel-LucentUnpublished and Not for Publication
All Rights Reserved
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28
Software Release Description
Network Element (NE) Software Version 11.01.28
Craft Interface Terminal (CIT) Software Release.18.09.05, Build.5091
Issue 1.0
Nov. 2012
Alcatel-Lucent - Proprietary
See Notice on first page
This material is protected by the copyright and trade secret laws of the United States and other
countries. It may not be reproduced, distributed or altered in any fashion by any entity (either
internal or external to Alcatel-Lucent), except in accordance with applicable agreements,
contracts, or licensing, without the express written consent of Alcatel-Lucent and the business
management owner of the material.
Trademarks
All trademarks and service marks specified herein are owned by their respective companies.
Notice
Every effort was made to ensure that this information product was complete and accurate at the
time of printing. However, information is subject to change.
Mandatory customer information
This information product does not contain any mandatory information.
Software copyright
Portions copyright by Atos Origin Integration under MARBEN™ Products
Legal Notices applicable to any software distributed alone or in connection with the
product to which this document pertains, are contained in files within the software itself located
at:
− the software distribution CD available with the product at /Licenses
− the WaveStar® CIT interface; selecting the Help About Licenses button from the Wave-
Star® CIT system view.
See the 1675 LambdaUnite MSS User Provisioning Guide for additional information about how
to access the WaveStar® CIT.
Support
Technical support
Please contact your Alcatel-Lucent Local Customer Support Team (LCS) for technical questions
about the information in this document.
C O N T E N T S
i i iAlcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),
Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
...............................................................................................................................................................................................................................................................
Contents
............................................................................................................................................................................................................................................................
A About this Document
............................................................................................................................................................................................................................................................
1 New Features
Overview 1 - 3
New Features of R11.01.28 1 - 4
New Features of R11.01.25 1 - 5
New Features of R11.01.20 1 - 6
New Features of R11.1.11 1 - 7
New Features of R11.1 1 - 8
New Features of R11.0 1 - 9
............................................................................................................................................................................................................................................................
2 Fixed Problems
Introduction 2 - 3
Fixed Problems in Release 11.01.28 2 - 4
Fixed Problems in Release 11.01.27 2 - 5
Fixed Problems in Release 11.01.26 2 - 7
Fixed Problems in Release.11.01.25 2 - 9
Fixed Problems in Release.11.01.20 2 - 10
Fixed Problems in Release.11.1.11 2 - 12
Fixed Problems in Release.11.1.1 2 - 13
Fixed Problems in Release.11.1 2 - 20
Fixed Problems in Release.11.0 2 - 25
............................................................................................................................................................................................................................................................
3 Known Problems
Introduction 3 - 2
Known Problems 3 - 3
............................................................................................................................................................................................................................................................
4 New Installation and Upgrade Procedures
General 4 - 4
Upgrade path survey 4 - 5
...............................................................................................................................................................................................................................................................
C O N T E N T S
i vAlcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),
Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
New Installation and Software Upgrade 4 - 6
Overview 4 - 6
To perform an initial NE software download 4 - 7
NE Software Upgrade 4 - 12
To upgrade software to a new release 4 - 12
To perform an NE software download for upgrade purposes 4 - 20
To activate an NE software generic 4 - 26
To check for successful NE software upgrade 4 - 32
To solve NE software upgrade problems 4 - 33
To retrieve NE software generic information 4 - 42
Supporting information for “Retrieving NE software generic information” 4 - 43
Database backup 4 - 45
Overview 4 - 45
To limit the number of saved backups 4 - 45
Manually backup database to the WaveStar® CIT 4 - 47
To retrieve NE database information 4 - 51
Supporting information for Retrieving NE database information 4 - 52
To restore a database to a network element 4 - 54
............................................................................................................................................................................................................................................................
5 Miscellaneous
Supported NE Releases with WaveStar®.CIT 5 - 2
Technical Support (TSC/TEC) 5 - 3
A - 1Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
...............................................................................................................................................................................................................................................................
A About this Document
Purpose The 1675 LambdaUnite®.MultiService.Switch.(MSS) Release 11.01.28
Software Release Description (SRD) provides procedural information
required to install the 1675 LambdaUnite®.MultiService.Switch.(MSS)
Network Element (NE) software and WaveStar®.CIT (Craft Interface
Terminal) software. It also includes a listing of new features, known
problems, fixed problems, and other helpful information.
Reason for reissue This is the initial version of this document for 1675
LambdaUnite®.MultiService.Switch.(MSS) Release 11.01.28.
Intended audience This document is intended for those responsible for the installation,
acceptance, operations, and maintenance of Release 11.01.28.
How to Use This Document Each chapter of this document treats a specific aspect of the system and
can be regarded as an independent description. This ensures that readers
can inform themselves according to their special needs. This also means
that the document provides more information than needed by many of
the readers. Before you start reading the document, it is therefore
necessary to assess which aspects or chapters will cover the individual
area of interest.
...............................................................................................................................................................................................................................................................
About this Document
A - 2 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
The following briefly describes the type of information found in each
chapter.
Section 1 - New Features
This section provides a listing of 1675.LambdaUnite®.MSS features that
are new.
Section 2 - Fixed Problems
This section provides a listing of the problems from the previous
1675.LambdaUnite®.MSS Network Element (NE) software/hardware
and WaveStar®.CIT (Craft Interface Terminal) software releases that
have been fixed in 1675.LambdaUnite®.MSS Release 11.01.28.
Section 3 - Known Problems
This section provides descriptions and workarounds to existing problems
in 1675.LambdaUnite®.MSS Release 11.01.28 and WaveStar®.CIT
Release.18.09.05.
Section 4- Upgrade Procedure
This section provides the procedure to upgrade the WaveStar®.CIT
(Craft Interface Terminal) software on the PC or Laptop and the
1675.LambdaUnite®.MSS Network Element software of an existing
1675.LambdaUnite®.MSS system to 1675.LambdaUnite®.MSS Release
11.01.28.
Section 5- Miscellaneous
This section provides useful information to supplement the information
provided in the previous sections.
1 - 1Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),
Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
...............................................................................................................................................................................................................................................................
1 New Features
............................................................................................................................................................................................................................................................
Contents 0
Overview 1 - 3
Purpose 1 - 3
Standards Compliance 1 - 3
New Features of R11.01.28 1 - 4
CIT 1 - 4
Features blocked in R11.01.28 1 - 4
New Features of R11.01.25 1 - 5
Software Features 1 - 5
Features blocked in R11.01.25 1 - 5
New Features of R11.01.20 1 - 6
Software Features 1 - 6
Features blocked in R11.01.20 1 - 6
New Features of R11.1.11 1 - 7
Software Features 1 - 7
Features blocked in R11.1.11 1 - 7
New Features of R11.1 1 - 8
Software Features 1 - 8
Features blocked in R11.1 1 - 8
...............................................................................................................................................................................................................................................................
New Features
1 - 2 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),
Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
New Features of R11.0 1 - 9
Hardware 1 - 9
Software Features 1 - 9
New Features
...............................................................................................................................................................................................................................................................
1 - 3Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),
Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Overview 0
Purpose The following chapter briefly list the most important new features of
1675.LambdaUnite®.MSS Release 11.01.28. For the complete and
detailed feature content of 1675.LambdaUnite®.MSS Release 11.01.28
please refer to the 1675.LambdaUnite®.MSS Product Information and
Planning Guide and 1675.LambdaUnite®.MSS User Provisioning Guide
respectively.
Please note that in the case of upgrade, dependent on the release the
upgrade starts from, the new features of 1675.LambdaUnite®.MSS
Release 11.01.28 are a set of the new features of all intermediate
releases.
Standards Compliance Alcatel-Lucent SONET and SDH products comply with the relevant
European Telecommunication Standardization Institute (ETSI),
Telcordia™ Technologies, and International Telecommunications Union
- Telecommunication standardization sector (ITU-T) standards.
Important functions defined in SONET and SDH Standards such as the
Data Communications Channel (DCC), the associated 7-layer OSI
protocol stack, the SONET and SDH multiplexing structure and the
Operations, Administration, Maintenance, and Provisioning (OAM&P)
functions are implemented in Alcatel-Lucent product families.
Alcatel-Lucent intelligent control plane, implemented in
1675.LambdaUnite®.MSS as ONNS, is based on standards discussed in
the ITU-T Automatically Switched Optical Network (ASON), the
Internet Engineering Task Force (IETF) Generalized Multi Protocol
Label Switching (GMPLS) Forum and the Optical Internet Forum (OIF).
Alcatel-Lucent is heavily involved in various study groups with ITU-T,
Telcordia™ and ETSI work creating and maintaining the latest
worldwide SONET and SDH standards. 1675.LambdaUnite®.MSS
complies with all relevant and latest Telcordia™, ETSI and ITU-T
standards and supports both, SONET and SDH protocols in a single
hardware-software configuration.
Exceptions to this standard compliances and other minor defects of this
release are described in chapter 3 “Known Problems” of this document.
...............................................................................................................................................................................................................................................................
New Features
1 - 4 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),
Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
New Features of R11.01.28 0
CIT • Support of Windows® 7
Features blocked in
R11.01.28
• ONNS
• MS-SPRing TOP+EX
• 1:1 MSP
• this release is not intended for use in SDH networks
Due to the support of Windows 7 the JRE version had to be changed, so
WaveStar CIT no longer supports the NE’s BWM and TDM10G (please refer to
chapter "Known Problems", sub-chapter "CIT")
New Features
...............................................................................................................................................................................................................................................................
1 - 5Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),
Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
New Features of R11.01.25 0
Software Features • LCAS on ES64U*
Features blocked in
R11.01.25
• ONNS
• MS-SPRing TOP+EX
• 1:1 MSP
• this release is not intended for use in SDH networks
WaveStar CIT no longer supports Microsoft Windows 2000.
*: The ES64U does not support mixed LCAS/non-LCAS mode. Soenabling LCAS on a link involving ES64U must be done synchro-nized as much as possible on both ends of the link to minimize thetraffic hit.
...............................................................................................................................................................................................................................................................
New Features
1 - 6 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),
Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
New Features of R11.01.20 0
Software Features • PM per flow on ES64U
• Adjustable Queue Weights
• Logging of CLI session Attempts
• Support of secure FTP*
• Alphanumeric CircuitId
• Support of FOSS (Free and Open Source Software)
Features blocked in
R11.01.20
• ONNS
• MS-SPRing TOP+EX
• 1:1 MSP
• this release is not intended for use in SDH networks
*: In the configuration of the ssh daemon tcp port forwarding must beenabled on the EMS/NMS server
New Features
...............................................................................................................................................................................................................................................................
1 - 7Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),
Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
New Features of R11.1.11 0
Software Features • ES64U: Enhanced number of CLI sessions: up to 6
• Enable-disable LACP also for an active LAG group
• Retrieval of flow information based on the VLAN tag
• LAG according to IEEE 802.3-2005 chapter 43
• Support of up to 6 unprotected ES64U cards
• Service Mirroring
• Oversubscription
• ES64U: Rolling Upgrade/Downgrade to minimize traffic impact
Released post DR4:
• PM per flow on ES64U
• Adjustable Queue Weights
Features blocked in
R11.1.11
• ONNS
• MS-SPRing TOP+EX
• 1:1 MSP
• this release is not intended for use in SDH networks
...............................................................................................................................................................................................................................................................
New Features
1 - 8 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),
Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
New Features of R11.1 0
Software Features • 3 pairs of 1+1 equipment-protected ES64U packs per NE
• Preparation of rolling upgrade/downgrade of ES64U
• Rolling restore of ES64U
• Support of TL1 command log
Features blocked in R11.1 • ONNS
• MS-SPRing TOP+EX
• 1:1 MSP
• this release is not intended for use in SDH networks
New Features
...............................................................................................................................................................................................................................................................
1 - 9Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),
Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
New Features of R11.0 0
Hardware • ES64U - Portless 20G Packet Switching Card
Software Features • ES64U HW Support
• ES64U Equipment Protection
• ES64U Maintenance
• ES64U mapping to STS1-kv
• ES64U VLAN switching
• EPL, EVPL and MEF 10 compliant E-Line and service
multiplexing on ES64U
• ES64U PM counter support
• ES64U CLI/SNMP provisioning and supervision
• Number of uni-directional VLAN cross-connections
• VLAN tag swapping
• ES64U 252 ports
• ES64U Ether Type provisioning per port
• ES64U Disable policing per flow
• ES64U Jumbo frame support on ports 1…30, 129..158
• ES64U QoS
...............................................................................................................................................................................................................................................................
New Features
1 - 1 0 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),
Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
2 - 1Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
...............................................................................................................................................................................................................................................................
2 Fixed Problems
............................................................................................................................................................................................................................................................
Contents 0
Introduction 2 - 3
Fixed Problems in Release 11.01.28 2 - 4
Area Packet Management 2 - 4
Fixed Problems in Release 11.01.27 2 - 5
Area Installation, Software Download, Backup & Restore, Upgrade 2 - 5
Area Performance Monitoring 2 - 5
Area Packet Management 2 - 6
Fixed Problems in Release 11.01.26 2 - 7
Area Packet Management 2 - 7
Fixed Problems in Release.11.01.25 2 - 9
Area Packet Management 2 - 9
Fixed Problems in Release.11.01.20 2 - 10
Area Protection (BLSR/MS-SPRing, DRI/DNI, APS/MSP, UPSR/SNCP) 2 - 10
Fixed Problems in Release.11.1.11 2 - 12
Area Configuration Management 2 - 12
Fixed Problems in Release.11.1.1 2 - 13
Area Installation, Software Download, Backup & Restore, Upgrade 2 - 13
Area Configuration Management 2 - 14
Area Protection (BLSR/MS-SPRing, DRI/DNI, APS/MSP, UPSR/SNCP) 2 - 15
Area Performance Monitoring 2 - 16
...............................................................................................................................................................................................................................................................
Fixed Problems
2 - 2 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
Area Packet Management 2 - 17
Area CIT 2 - 19
Fixed Problems in Release.11.1 2 - 20
Area Performance Monitoring 2 - 20
Area Installation, Software Download, Backup & Restore, Upgrade 2 - 20
Area Packet Management 2 - 21
Area Equipment Protection 2 - 24
Fixed Problems in Release.11.0 2 - 25
Area Protection (BLSR/MS-SPRING, DRI/DNI, APS/MSP, UPSR/SNCP) 2 - 25
Area DCC/DCN Management 2 - 25
Area Packet Management 2 - 26
Area CIT 2 - 27
Fixed Problems
...............................................................................................................................................................................................................................................................
2 - 3Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Introduction 0
This chapter provides a listing of the problems from the previous
1675.LambdaUnite®.MSS Network Element (NE) software/hardware
and WaveStar®.CIT (Craft Interface Terminal) software releases that
have been fixed in 1675.LambdaUnite®.MSS Release 11.01.28.
Please note that in the case of upgrade, dependant on the release the
upgrade starts from, the fixed problems of 1675.LambdaUnite®.MSS
Release 11.01.28 are a set of the fixed problems in all intermediate
releases.
Fixed Problems have been grouped into the following functional areas
• Area Installation, Software Download, Backup & Restore, Upgrade
• Area Configuration Management
• Area Synchronization Management
• Area ONNS
• Area Protection (BLSR/MS-SPRING, DRI/DNI, APS/MSP,
UPSR/SNCP)
• Area Equipment Protection
• Area Fault/Alarm Management
• Area Performance Monitoring
• Area DCN/DCC Management
• Area Security Management
• Area Packet Management
The syntax of the problem number (e.g. Fixed Problem 2.0 - nb12345) is
as follows:
• first part: the problem is known since this release
• second part: internal number
...............................................................................................................................................................................................................................................................
Fixed Problems
2 - 4 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Fixed Problems in Release 11.01.28 0
Area Packet Management Problem 11.1.27 - nb95128
ES64U: Traffic Hits of up to several hundred msec in case of LAG
switch
When using LAG to group some links connected to ports of an ES64U a
failure of one leg causes the LAG state machine to not use this leg any
longer. As a side effect of some other code changes the time to recognize
the failure until the LAG state machine has switched away from the
failed leg has increased significantly from about 100msec to up to 800
msec.
Fixed Problems
...............................................................................................................................................................................................................................................................
2 - 5Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Fixed Problems in Release 11.01.27 0
Area Installation, Software
Download, Backup &
Restore, Upgrade
Problem 11.1.20 - nb95029
Rolling Upgrade of ES64U may get stuck in rare cases
It has been observed that in rare cases the rolling SW upgrade of
equipment-protected ES64U pairs may get stuck. The root cause is that
after starting up the standby ES64U with the new SW generic the
indication that this card has finished its restart and is operational is lost.
Only after a timeout of six hours the rolling upgrade will resolve this
stuck state by applying a reset to the standby ES64U. This stuck state
may occur only if more than one ES64U EQP group is existing.
Problem 11.1.20 - nb95005
ES64U: Failed ZBT RAM not detected by startup diagnostics
When the ZBT RAM of ES64U has a permament failure this may not be
detected by the diagnostics checks performed during startup. Such a
failure may lead to strange effects on traffic, e.g. a duplication of
Ethernet frames.
Area Performance
Monitoring
Problem 11.1.1 - nb92805
ES64U CLI/SNMP command pmperqeth shows wrong current pm
counters & becoming zero after crossing 15 minutes interval (on history
view)
In certain configurations (mainly in 10G traffic), the current pm counters
per queue of this port show giant wrong values and after crossing
15minutes interval , their value become zero.
...............................................................................................................................................................................................................................................................
Fixed Problems
2 - 6 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
Area Packet Management Problem 11.1.1 - nb94853
ES64U: System Timers not working anymore after uptime of about
497 days
When an ES64U is up and running for more than 497 days, 2hours, 27
minutes and 53 seconds since the last reboot internal timers are not
working correctly anymore. This has severe impact on system
functionality.
E.g. for Link Aggregation Groups with LACP being enabled the periodic
transmission of LACP messages is stopped, so that the LACP peer will
declare these links as failed, thus dropping traffic.
Problem 11.01.25 - nb95027
ES64U: Transmission of LACP messages for non-Attached LAG links
stops without obvious trigger
When using Link Aggregation groups with LACP being enabled where
not all members are in state Attached (e.g. in combination with Multi-
Chassis LAG of 7750 only the active leg is Attached, the standby leg is
shown to be in state "Reserved") the periodic transmission of LACP
messages for such a non-Attached LAG leg may suddenly stop without
any obvious trigger. The LACP peer will declare this LAG leg as Failed,
effectively losing protection of the active leg.
The root cause is a wrong handling of a FIFO buffer inside the ES64U
used for LACP message transport. If the buffer ran full once then only
corrupted LACP messages will be passed through this FIFO, being
dropped further down in the transmission path on ES64U.
Fixed Problems
...............................................................................................................................................................................................................................................................
2 - 7Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Fixed Problems in Release 11.01.26 0
Area Packet Management Problem 10.5.2 - nb94495
GE10PL1: First Controller Reset in 10GbE mode not hitless after
reducing VCG size
When operating a GE10PL1 pack in 10GbE mode the first Controller
Reset after reducing the size of the VCG by disabling one or more
members is not hitless as expected. Instead a traffic hit of a few seconds
can be observed. Subsequent Controller Resets are hitless as expected.
Problem 10.5.52 - nb94572
GE10PL1: Controller Reset not always hitless for 10GbE/STS1-
192v
When using GE10PL1 in 10GbE mode with an STS1-192v VCG having
all 192 members enabled and all VCGTribs are set to monitored a
Controller Reset of the pack is not hitless when LPT is enabled. Due to
some race conditions while the pack is starting up the laser is switched
off for about one to three seconds. This effect cannot be observed when
VCGTrib monitoring is disabled or when the VCG size is VC4-64v. It is
assumed that also in STS1-kv case for smaller VCG sizes this effect
cannot be observed.
Problem 11.1.25 - nb94638
ES64U: Loss of a single Ethernet frame when adding another flow to a
port which is used as output port of other flows
When adding flows having an output port which is already used as
output port of other flows then a single frame belonging to the
previously existing flows is lost.
...............................................................................................................................................................................................................................................................
Fixed Problems
2 - 8 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
Problem 11.1.11 - nb94697
ES64U: Reboot of active and standby ES64U when using SNMP
community string intended for GET requests also for SNMP SET
requests.
When sending an SNMP SET request but using the SNMP community
string intended for GET requests and ES64U is used in a an equipment
protection group, then the local data controllers (LDC) of active and
standby ES64U perform a reboot more or less in parallel. Consequently
traffic is lost until the active ES64U has finished its reboot.
This reboot only happens in equipment-protected mode of operation.
Fixed Problems
...............................................................................................................................................................................................................................................................
2 - 9Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Fixed Problems in Release.11.01.25 0
Area Packet Management Problem 11.1.11 - nb94474 / nb94275
Alarm for QDR parity errors missing
On rare occasions defective hw inside the ES64U can cause “Quad Data
Rate (QDR) Parity Errors”. By this the ES64 will erroneously discard
packets.
While this problem is infrequent, ALU has added additional alarming
and automatic switch protection to release R11.01.25 (1675 LU). I.e.
these QDR parity errors will be alarmed as HWFAIL followed by an
automatic protection switch if detected.
...............................................................................................................................................................................................................................................................
Fixed Problems
2 - 1 0 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Fixed Problems in Release.11.01.20 0
Area Protection (BLSR/MS-
SPRing, DRI/DNI, APS/MSP,
UPSR/SNCP)
Problem 11.1 - nb89969
Parameters of a path protection group with output in an ACG port
on DS-3 side of a TMUX2G5/1 cannot be edited
If a path protected cross connection has its output tributary in an ACG
port of the asynchronous side of the TransMUX unit TMUX2G5/1 then
the parameters of this protection group cannot be changed afterwards.
The related TL1 command ED_PROTN-GRP is denied with "Input,
Entity Not Exists". This denial affects attempts to change the following
parameters: associated alarm severity profile, hold-off timer, mode of
operation, SNCP type, wait to restore timer.
Problem 10.5.41 - nb93543
Toggling HO-SNCP/UPSR switches may cause CTL reboots and
other side effects due to overload
When the input signals of HO-SNCP/UPSR selectors are permanently
toggling this causes permanent state changes or even permanent
protection switches. Those state changes and protection switches have to
be processed by the system to update the internal database and to report
those changes at the TL1 interface. Due to this massive processing the
system enters an overload condition where it is more or less
unmanagable via TL1. Additionally this may cause also various side
effects:
- periodic CTL reboot about every eight hours due to running out of
memory
- CTL/DCF reboot leading to drop of management connections
- XC reboots (usually no impact in non-ONNS systems)
- CTL hang-up due to failing system shutdown (observed once)
- A traffic outage was observed once which occured due to a parallel Full
Reset of XC and a reboot of the CTL.
Fixed Problems
...............................................................................................................................................................................................................................................................
2 - 1 1Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Problem 8.0.1 - nb66277 (nb68110)
Wrong Traffic Squelched Alarm during MS-SPRing/BLSR node deletion
When a node is deleted from an MS-SPRing/BLSR ring by using the
recommended procedure, a Traffic Squelched alarm might be raised by
the nodes adjacent to the deleted one. When following this procedure,
the node to be deleted is not allowed to have other connections than
higher order (HO) through connections carrying circuits originally
routed via the deleted node. For these HO through connections no
squelching must occur in this scenario and has also not been encountered
during tests. The wrong Traffic Squelched alarm clears together with the
Ring Protection Switch Suspended alarm.
...............................................................................................................................................................................................................................................................
Fixed Problems
2 - 1 2 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Fixed Problems in Release.11.1.11 0
Area Configuration
Management
Problem 11.1 - nb93166
Autonomous ES64U reboots
When using any prolonged CLI scripting to access ES64U units with
R11.1.0 or R11.1.1, these commands consume memory improperly over
time resulting in resource congestion of the ES64U’s memory.
The following has been observed:
• ES64U boards may autonomously reboot (typically STDBY only and
non-traffic effecting)
• Sometimes ES64U reboot switches lead to customer login "lockouts"
that require further intervention to clear (also not traffic effecting if
resolved properly)
• Less frequently an active and standby ES64U reboot can occur
simultaneously leading to a temporary outage, based on number of flows
provisioned.
Fixed Problems
...............................................................................................................................................................................................................................................................
2 - 1 3Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Fixed Problems in Release.11.1.1 0
Area Installation, Software
Download, Backup &
Restore, Upgrade
Problem 11.1 - nb89775 (90044)
ES64U: Sometimes CPFail after pack reboot
After a reboot of ES64U, e.g. due to EQP creation or EQP switches,
sometimes a CPFail is raised for this pack. Applying another Controller
Reset or Full Reset to the pack usually clears the CPFail, in rare cases
another reset is required. If such a pack is part of an equipment
protection group it cannot become active. If it is unprotected traffic is
lost. The probability of this effect is about 20%.
Problem 11.1 - nb90066
Rolling DB Restoration or Rolling SW Upgrade in a ES64U
configuration where the standby ES64U is pulled takes several
hours until new configuration/new SW generic is activated,
potentially causing traffic interruption for several hours.
When performing a DB Restoration/SW Upgrade to a system where
equipment-protected ES64U packs are provisioned a rolling DB
restore/SW upgrade is initiated to minimize traffic impact. However, if
the standby pack is pulled when initiating the rolling restore/SW upgrade
the system waits for a period of 6 hours until the (pulled) standby ES64U
indicates that it has finished its initialization. Only after this timeout of
six hours this process is interrupted and the active ES64U pack is reset to
restart and reconfigure it with the new database/SW generic.
This means that in case of a DB restore where
- the active ES64U is still operational with the old database the new
database will not be active before the six hours timeout plus the time
until it has restarted and applied the new configuration. During the six
hour timeout the active ES64U will continue to forward traffic according
to the old configuration.
- the active ES64U is not operational traffic is interrupted for thetimeout
period of six hours plus the time the ES64U needs to complete
initialization according to the new configuration.
...............................................................................................................................................................................................................................................................
Fixed Problems
2 - 1 4 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
In case of a SW Upgrade the first case above applies, i.e. active ES64U
continues to run the old SW generic during the timeout period.Traffic is
interrupted after the timeout until the new generic has completed starting
up and has applied the configuration to HW.
Area Configuration
Management
Problem 11.1 - nb89839
ES64U: CPCOMF alarms during extensive provisioning activities or
DB restore
When performing extensive provisioning activities, e.g. when enabling
the input and output membership of an ES64U VCG provisioned for
10GbE capacity (i.e. STS1?192v) by sending a sequence of TL1
commands one after the other or during a DB restore temporary
CPCOMF alarms may be raised due to ES64U being in an overload
condition. Such activities usually take very long (enabling of all 192
members of a 10G VCG may take 4 to 5 minutes).
In case of bulk configurations of multiple VCGs also an overload
condition on standby XC has been observed, leading to a temporary
CPCOMF alarm of the standby XC pack as well.
In the case of enabling 192 members of a 10G VCG also toggling
GFPLFD and GFPCSF alarms may occur if the cross?connections
related to the involved VCG are already created and the remote end of
the VCG link is already provisioned and working.
Problem 9.0.4 - nb89704
Explicit or implicit sub structure change of 1st TUG-3 from 21 *
TU-12 into TU-3 disturbs all TU-12s in the 2nd and 3rd TUG-3
Explicit or implicit sub structure change of 1st TUG-3 from 21 * TU-12
into TU-3 disturbs all TU-12s in the 2nd and 3rd TUG-3 Customer
Impact: When in a system with LOXC40 the first TUG-3 of an egressing
VC-4 is currently sub-structured into 21 * TU-12 and then the sub-
structure of this first TUG-3 is changed into TU-3 then any VC-12 in the
second and third TUG-3 of the VC-4 will get a short traffic hit (about 70
ms). The root cause is that the multiframe indication of the egressing
VC-4 gets transiently lost. The substructure change in the first TUG-3
can be caused by an explicit sub structure change or by switching a VC-
3 cross connection.
Fixed Problems
...............................................................................................................................................................................................................................................................
2 - 1 5Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Area Protection (BLSR/MS-
SPRing, DRI/DNI, APS/MSP,
UPSR/SNCP)
Problem 11.1 - nb89960
Enabling of DCC protection not denied when transparent DCC
present
The ED-PROTN-GRP command is not denied, when DCC protection is
enabled (dcclmsprotmd=ENABLE or dccsrsprotmd=ENABLE) for a
MS protection group while transparent DCC cross connections are
present at the protection port.
This results in an illegal configuration with the transparent DCC not
working properly. According to the test results, the protected DCC at the
worker port is OK.
Problem 10.5.2 - nb89992 (nb89716)
Auto-recovery might be not complete after an input power interrupt
or an INIT-SYS command
During a restart due to a power interrupt or an INIT-SYS TL1 command
it can occur that the lasers of ports in BLSR or MS SPRING protection
groups are not switched on again or that the lasers are switched on, but
the K-byte protocol is not correctly re-started. Consequently the ports in
the neighbor nodes continue to indicate LOS alarms for the links sourced
from the affected ports or the neighbor nodes will raise DefaultKbytes
(DKB) alarms for these links. The problem is caused by race conditions
during system recovery and has been observed for systems equipped
with CTL/-.
Problem 8.0.24 - nb90738
A path might transmit AIS caused by incomplete removal of
previous MS-SPRING / BLSR squelching actions
A path might transmit path AIS if for one of its path segments the
following history is true:
1. The path segment has been part of a BLSR or MS SPRING
2. Traffic has been squelched on this segment (i.e. path AIS has been
inserted into the path segment in accordance with the situation in the
MSSPRING / BLSR)
...............................................................................................................................................................................................................................................................
Fixed Problems
2 - 1 6 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
3. Protection switching has been suspended while squelching was still
active. One potential root cause for suspension of protection switching is
that a node has been added to or removed from the ring.
4. The reason for the squelching has cleared while protection switching
was still suspended. One reason for that is that the cross connections of
the path segment have been deleted. Another could be that the ring
topology has been changed again.
In this case the AIS which has been inserted due to the squelching action
is not physically removed. Consequently the AIS insertion will remain
and will have impact on the current path (if there is still any) or on any
new path which is set up later and which is routed across the timeslots of
the affected bandwidth.
Area Performance
Monitoring
Problem 11.1 - nb89343
ES64U: PM Data retrieved via CLI/SNMP might show wrong
information on discarded frames
In case of congestion the PM data available via CLI/SNMP might show
wrong information w.r.t. dropped frames. In a scenario with two flows,
one with 1G CIR, the other with 1G EIR, both having the same output
port with just 1G output capacity the following can be observed:
- Frame forwarding works as expected, i.e. all CIR frames are
forwarded, only EIR frames are dropped
- However, PM data retrieval indicates that also green (CIR) frames are
dropped, which is not correct.
The NP of ES64U seems to count yellow frames being dropped
erroneously as green.
Beside the wrong counting no further bad side effect is known. The
observed behavior seems to occur only under heavy load conditions of
the NP.
Fixed Problems
...............................................................................................................................................................................................................................................................
2 - 1 7Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Problem 11.0 - nb87228
ES64U do not count Dropped frames in pm counter.
Frames, which exceed the defined size (2026 bytes) of the egress port,
are correctly dropped but not counted in the related pm counter. The
retrieve of the related PM counter e.g. via CLI shows zero dropped
frames.
Area Packet Management Problem 11.1 - nb89979
When switching a FSF-loop on a 10GbE port of GE10PL1 a
LANPHYNOSYNC alarm is raised and Client-signal-fail is
indicated via the WAN-link towards the remote NE.
When enabling the far-side-facility loopback at a 10GbE LAN port of
the GE10PL1 the system detects an unexpected NOSYNC condition and
raises the LANPHYNOSYNC alarm. This leads to sending a Client-
Signal-Fail indication via the WAN-link towards the remote end. This
triggers a consequent action (e.g. disable the laser at the LAN-port) at
this remote NE, if enabled, and disrupts the looped traffic.
This applies for 10GbE ports, only. 1GbE ports are not affected.
Problem 11.0 - nb87233
Setting outmbs on ES64U for VCG tribs to disable does not
influence CSF
When you set a unidirectional cross-connections from the ES64U
towards GE10PL1, CSF is always transmitted upstream. The parameter
OUTMBS (output membership) in TL1 command ED-VCGTRIB has no
impact to the CSF control.
...............................................................................................................................................................................................................................................................
Fixed Problems
2 - 1 8 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
Problem 10.5.2 - nb89604
In rare cases a CPCommFail alarm may be raised for GE10PL1
during normal operation
It has been observed in rare cases that during normal operation, either
while processing autonomous events caused by WAN failures or while
processing provisioning requests, a CPCommFail alarm is raised for
GE10PL1 packs permanently. The reason for this CPCommFail alarm is
that the pack does no longer send periodic fault status information to
CTL. Consequently fault reporting for the pack in this state no longer
works.
Problem 9.0 - nb73869
GE10PL1: Traffic might not come up after fast disabling and
re-enabling of VCG members
When disabling VCG members with a delay of less than two seconds
and interleaved at both ends of a VCG trail (i.e. disabling member #1 at
near end, then disabling member #1 at far end, then #2 at near end, #2 at
far end, and so on) bandwidth is reduced as expected and after disabling
the last member traffic is interrupted as expected.
When enabling some or all of these members again (regardless of order,
quantity or delay between the commands) traffic might not be
established as expected. Instead some of the members use wrong
sequence numbers so that the LCAS sink cannot re-assemble the
Ethernet frames from the GFP stream.
This effect was not observed, when disabling the members first at one
side, then at the other, or when waiting for two seconds between the
commands to disable the members.
Fixed Problems
...............................................................................................................................................................................................................................................................
2 - 1 9Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Area CIT Problem 10.5.1 - nb91618
WS-CIT sometimes faces difficulties to maintain connection to
LambdaUnite via TCP/IP
In rare cases the connection from CIT to LambdaUnite via TCP/IP gets
interrupted
...............................................................................................................................................................................................................................................................
Fixed Problems
2 - 2 0 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Fixed Problems in Release.11.1 0
Area Performance
Monitoring
Problem 10.5 - nb86495
Wrong DS1 PM counters on TMUX2G5 in case of DS1-LOF
When a TMUX2G5 detects a DS1-LOF condition the PM counters do
not correctly reflect this. The counter ES-P, SES-P, SAS-P and
consequently UAS-P are not incremented further as long as the LOF
condition is persistently present.
Problem 10.0 - nb87393
During Loss of signal condition wrong Received bytes may be
counted by PM counters
In the case of a loss of signal condition at a optical interface module of
the 10GPL1 (LANLOS or NOSYNCH condition) a possible optical
noise may mimic valid bytes which are counted in the EONB and EINB
PM counts and give the wrong impression of a valid signal. During such
period no valid frames are counted.
Area Installation, Software
Download, Backup &
Restore, Upgrade
Problem 11.0 - nb87260
ES64U: No provisioning possible for some time during a DB backup
While executing a DB backup from the system there is a time window
where no provisioning actions can be executed on ES64U via
CLI/SNMP. This time window is related to the timeframe where the
ES64U database is copied to CTL for further processing together with
the database part s stored on CTL. Provisioning requests via CLI/SNMP
are denied during this timeframe.
Problem 11.0 - nb87589
ES64U: Wrong LED indication when opening the upper latch while
pack is still starting up
When opening the upper latch of ES64U a graceful shutdown should be
initiated allowing to complete pending operations on CF-disk of ES64U
to avoid file system corruptions.
Fixed Problems
...............................................................................................................................................................................................................................................................
2 - 2 1Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
However, when opening the upper latch while the pack is not yet
operational the LEDs of ES64U indicate immediately that the pack can
be safely pulled (i.e. green LED off, red LED on) even though the
shutdwon actions are not yet completed (if started at all). When pulling
the pack immediately there is a risk of corrupting the file system and
losing the database.
Problem 11.0 - nb87410
ES64U databases not restored on NE with empty database
The ES64U databases contained in a downloaded DB generic are not
restored to the ES64U, if the NE in in maintenence mode after restert
with empty database. This problem is relevant for fall back after upgrade
failures and recovery after CTL failures. In both scenarios, the NE is
restarted with an empty database, what leads to maintenance mode. Then
the last backup is downloaded and applied. This should restore the NE
datbase and all ES64U datbases. But because af the problem, only the
NE database is restored.
Workaround:
Download the database generic again an apply it. But this leads to a
traffic outage for the traffic through the ES64U.
Area Packet Management Problem 11.0 - nb87285
ES64U: Green LED not flashing when opening upper latch
In order to properly shutdown an ES64U pack a special procedure
described in UPG is required to safely shut down the pack. According to
this procedure the upper latch must be opened at first, then it must be
waited until green LED stopped flashing and red LED goes on, before
opening the lower latch as well.
After opening the upper latch the green LED should start flashing to
indicate to the operator that shutdown tasks are going on. However, the
green LED remains in its previous state, i.e. either permanently on or off,
until the shutdown tasks are completed. It is then switched off as
expected.
So the difference to the expected behavior is that it is not flashing during
execution of the shutdown tasks
...............................................................................................................................................................................................................................................................
Fixed Problems
2 - 2 2 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
Problem 10.5 - nb79161
GE10PL1: After Controller Reset some VCG members may end in
state FAILED, thus WAN bandwidth is reduced
When applying a Controller Reset to a GE10PL1 at one end of a VCG
trail it may happen that some VCG members enter the state FAILED,
even though the path is error free. Consequently the WAN bandwidth is
reduced.
This has been observed in different configurations:
• with LCAS htmr=0 at the end being reset and htmr=1sec at the
other end
• with symmetric setting of htmr=0 at both ends
When setting the hold-off symmetrically to 300ms at both ends the effect
was not observed.
When using the 10GbE interface with htmr=0 at the one end and 1sec at
the other end the issue was never observed in 230 runs.
Problem 8.0 - nb67830 (nb59928)
Traffic Hits on Controller Resets of GE10PL1
When applying a Controller Reset to the GE10PL1, e.g. by the TL1
command INIT-EQPT or during a software-upgrade, the resulting reboot
of the GE10PL1 is not hitless. Instead a traffic loss is observed:
• When using the 1GbE ports a traffic hit in the range of 1.2 to 2.2
seconds has been observed.
• When using the 10GbE port, a traffic hit in the range of 5 to 6
seconds has been observed.
At the remote side of the WAN-link a Total Loss of Capacity alarm will
be raised temporary caused by the traffic interruption.
If LCAS is enabled and the Wait-to-restore timer is set to a value higher
than zero (which is the default value) then this WTR-time adds to the
traffic interruption time.
Fixed Problems
...............................................................................................................................................................................................................................................................
2 - 2 3Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Problem 11.0 - ch00306
GE10PL1: LCAS WTR Timer also applied during Reset of
GE10PL1
When applying a reset to GE10PL1 while LCAS is enabled the LCAS
wait-to-restore (WTR) timer is also applied for VCG members becoming
good again.
In case of a Controller Reset traffic is affected due to another known
issue (nb67830). Once the VCG members become good again after the
initialization the currently provisioned WTR time is applied, extending
the outage time caused by the Controller Reset.
In case of a Full Reset traffic is interrupted anyhow. However, the time
until traffic is restored is extended by the currently provisioned LCAS
WTR (the default of this paramater is 0 min). This is not considered an
issue, because also after a full traffic loss, e.g. due to a fiber cut, the
WTR timer is applied for the first member to become good again, thus
extending the overall outage time by the WTR time.
Problem 10.0.1 - nb88600
GE10PL1: Switching and Releasing of FSF loop on 10GbE port not
reliable
When switching or releasing a Far-side facility (FSF) loop at the 10GbE
port of a GE10PL1 pack this operation is not reliable to take effect.
When switching the loop it might in fact not be switched even though the
system reports it to be active. When releasing a loop it might not be
released properly even though the system reports it to be released.
...............................................................................................................................................................................................................................................................
Fixed Problems
2 - 2 4 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
Area Equipment Protection Problem 11.0 - nb87590
ES64U: CPFail Alarm raised for several minutes when creating
ES64U EQP group
When creating an ES64U equipment protection group a CPFail alarm is
raised for the standby ES64U pack. The alarm is cleared after several
minutes during the process of initialization and synchronization of the
standby pack.
Fixed Problems
...............................................................................................................................................................................................................................................................
2 - 2 5Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Fixed Problems in Release.11.0 0
The problem communicated via the following alert has been fixed in
1675.LambdaUnite®.MSS Release.11.0:
• 08-0392 1675 LambdaUnite MSS - Loss of Management
Association
Area Protection (BLSR/MS-
SPRING, DRI/DNI,
APS/MSP, UPSR/SNCP)
Problem 9.1 - nb83992
Roll crossconnect command of the TU3-side of a AU3 to TU3
conversion connection fails if the source of the AU3 is sourced by a
DS3 located on a EP51
In the case a roll command for the TU3 side of a AU3 to TU3 conversion
connection (roll the LO TU3 to a new HO VC of a STM-N port) with the
AU3 being sourced by a DS3 from an EP51 is entered , this is rejected.
The error code of this invalid rejection is "Input, Data Not Consistent,
LO tributary not supported by that pack (e.g. OPT2G5, EP51, GE1)".
Area DCC/DCN
Management
Fixed Problem - nb86129/86194/86516 (Alert 08-0392)
Management systems may lose association to the 1675 LambdaUnite
and login is impossible
Management systems may lose association to the 1675 LambdaUnite
and login is impossible. It has also been observed that communication
between management systems and the 1675 LambdaUnite is very slow.
This is caused by memory leaks. Memory leaks occur with certain TL1
commands (primarily ENT-USER-SECU, ED-PID, ED-USER, ED-
USER-SECU, ENT-BANNER, ACT-USER, CANC-USER, CANC-
USER-SECU, and DLT-USER-SECU), Failed User login/logouts,
Enable/Disable DCC channels commands (ENT-FECOM), and Large
Memory Retrieval (LMR) commands where huge amounts of data are
requested.
Due to these leaks insufficient free memory is available on the CTL to
fulfill requests from the management system. Depending on the usage of
the NE and the controller type, the time until this effect becomes visible
may vary greatly.
On CTL/3T, the incidence of the problem is reduced due to the higher
amount of RAM Memory available. Also when the system is equipped
with this controller, an automatic reboot of the TL1 controller function
...............................................................................................................................................................................................................................................................
Fixed Problems
2 - 2 6 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
takes place when the consumed memory allocated to TL1 processing
exceeds a predefined threshold. This action may result in an autonomous
recovery from the problem. With CTL/- a loss of association will occur
when this threshold is met.
Area Packet Management Problem 10.0 - nb82430
GE10PL1: Traffic may not be established when sequence numbers
of VCG members are unsorted in non-LCAS mode
According to standards in non-LCAS mode the sequence numbers of
VCG members have to be sequential, i.e. the member i uses sequence
number (i-1). In LCAS-mode arbitrarily ordered sequence numbers are
allowed.
However, a VCG source of GE10PL1 does not behave according to
standard and may use unordered sequence numbers depending on the
order of provisioning:
• E.g. when enabling trib #1 and #3 followed by #2 the used sequence
numbers are 0, 2, 1 instead of 0, 1, 2
• When disabling LCAS the order of sequence numbers remains
unchanged. So when the sequence numbers were unordered before
switching off LCAS they remain unordered.
A VCG sink of GE10PL1 accepts arbitrarily ordered sequence numbers
and resorts the members accordingly. So connecting GE10PL1 to
GE10PL1 is not an issue. However, when interworking with equipment
which does not accept arbitrarily ordered sequence numbers no traffic is
possible over such a link.
Problem 10.0 - nb83029
GE10PL1: Long traffic interruptions in case of SDH/SONET
protection switches
When the pathes ending at a GE10PL1 are double-protected by LCAS
and SDH/SONET protection schemes, e.g. SNCP/UPSR, the traffic hit
on an Ethernet link in case of a SDH protection switch is longer than
without LCAS.
For a VC4-7v link the following traffic interruption times have been
measured with SNCP (LPT disabled, 2000 runs):
With LCAS disabled all times were below 80ms, 86% of the runs
showed even less than 60 msec (the interruption time usually allowed in
SDH protection schemes consisting of 10ms detection time plus 50ms
swicthing time)
Fixed Problems
...............................................................................................................................................................................................................................................................
2 - 2 7Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
On the other side, with LCAS enabled, resulted in times of up to 200
msec, in rare cases even higher.
If LPT is enabled (default) this might cause another interuption if the
corresponding hold-off timer is set to 0ms.
Area CIT Problem 11.0 - nb87272
CIT fails to send APPLY command after a successful DB Download
The user would assume the activation of the database, but CIT would not
have activated.
...............................................................................................................................................................................................................................................................
Fixed Problems
2 - 2 8 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
3 - 1Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
...............................................................................................................................................................................................................................................................
3 Known Problems
............................................................................................................................................................................................................................................................
Contents 0
Introduction 3 - 2
Known Problems 3 - 3
Area Installation, Software Download, Backup & Restore, Upgrade 3 - 3
Area Configuration Management 3 - 4
Area Protection (BLSR/MS-SPRing, DRI/DNI, APS/MSP, UPSR/SNCP) 3 - 5
Area Equipment Protection 3 - 7
Area Fault/Alarm Management 3 - 7
Area Performance Monitoring 3 - 8
Area Packet Management 3 - 9
Area CIT 3 - 14
...............................................................................................................................................................................................................................................................
Known ProblemsIntroduction
3 - 2 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Introduction 0
This chapter provides descriptions of significant customer-affecting
problems known to exist in 1675.LambdaUnite®.MSS Release 11.01.28
Network Element software/hardware and WaveStar®.CIT software.
Workarounds are provided where they apply.
Known Problems have been grouped into the following functional areas
• Area Installation, Software Download, Backup & Restore, Upgrade
• Area Configuration Management
• Area Synchronization Management
• Area Protection (BLSR/MS-SPRing, DRI/DNI, APS/MSP,
UPSR/SNCP)
• Area Equipment Protection
• Area Fault/Alarm Management
• Area Performance Monitoring
• Area DCN/DCC Management
• Area Security Management
• Area Packet Management
• Area CIT
The syntax of the problem number, e.g. “Problem 2.0 - nb12345” is as
follows:
• first part: the problem is known since this release
• second part: internal number
• in some cases a second internal number in brackets means that the
internal number of the problem has changed; the number in
brackets denotes the old number used in the Software Release
description of a former 1675.LambdaUnite®.MSS release
Known ProblemsKnown Problems
...............................................................................................................................................................................................................................................................
3 - 3Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Known Problems 0
0Area Installation, Software
Download, Backup &
Restore, Upgrade
Problem 11.1 - nb92850
Permanent Loss of management connection when connecting a QT600 test
set
It has been observed at customer sites that when connecting a JDSU
QT600 Ethernet test set to LAN port 2 of 1675 LambdaUnite a
CTL/DCF boot loop may occur, thus losing management connectivity to
this NE. The tester seems to have send an improper login request
followed by an abort request which is not correctly handled by DCF and
causes the reboot.
Workarounds:
There are two alternative workarounds.
The first one being to disconnect the QT600 from LAN2. The CTL will
autonomously clear the fault by a reboot.
If it is not desired to remove the JDSU QT-600 from the network, a
second option to clear this condition is to follow the steps below and
change the JDSU TAM Interface from Master to Passive. Once these
steps have been completed, this condition will autonomously clear from
the 1675 LU MSS with one completed reboot cycle of the CTL circuit
pack.
These steps have been provided by JDSU Technical Support as a high
level of the required steps. If additional assistance with these steps is
required, please contact your JDSU Technical Support organization for
further assistance.
Change the JDSU QT-600 Tam interface from Master to Passive on each
installed JDSU QT-600 in this location.
1. login in as craft
2. press 1 and then enter to continue into craft mode
3. press 3 and then enter for tam configuration
4. press 1 and then enter to select tam mode
5. press 1 and enter to select passive
6. press 0 and enter to return to previous menu
7. press 9 and enter to save
...............................................................................................................................................................................................................................................................
Known ProblemsKnown Problems
3 - 4 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
8. verify you see the tam mode is passive - tam mode passive should
appear on the top of the session.
9. press 0 and then enter to return to main menu
10. press 0 and then enter to exit and logout as craft
Once either of the above options has been performed, logins should be
allowed. In some instances it is possible that the 1675 LU MSS User ID
that was provisioned for the JDSU QT-600 has become invalid. If login
attempts using the JDSU QT-600 User ID are denied, delete this login
from the 1675 LU MSS and provision this User ID again exactly as it
was previously set. This will allow the JDSU QT-600 to establish login
session again.
0Area Configuration
Management
Problem 10.5.4 - nb94363
Sending two consecutive CTL Reset Requests within a few seconds may
cause CTL bootloop (simplex case) or an unusable CTL (duplex case)
When sending a command to request a CTL reboot and, within a few
seconds, sending the same request again, then this second request may
result in marking the CTL unusable. In a simplex configuration the CTL
will not be able to start up anylonger (boot loop). In a duplex
configuration this CTL will not become operational anymore. The same
may happen when sending a request to reset another pack as the second
command. The root cause is that the second request is started to be
processed, especially the check of SW generics on CF-disk is started a
second time, but this second check fails due to the shutdown actions
caused by the first reset request. This failed check marks the CF-disk as
unusable, such that this CTL cannot start up anymore. The commands
leading to a reset of the active CTL are
- INIT-EQPT with a CTL AID
- INIT-SYS
- Leave mcond (ED-STATE-EQPT with mcond=N)
- APPLY
in the course of a SW Upgrade
The commands triggering a check of the SW generics on CF-disk (i.e.
those which should be avoided to be sent as the second one) are
- INIT-EQPT to any pack
Known ProblemsKnown Problems
...............................................................................................................................................................................................................................................................
3 - 5Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
- INIT-SYS
- leave mcond (ED-STATE-EQPT with mcond=N).
Workaround:
Avoid to send multiple commands leading to a CTL reset within a few
seconds.
0Area Protection
(BLSR/MS-SPRing,
DRI/DNI, APS/MSP,
UPSR/SNCP)
Problem 10.5.2 - nb93224
Short Failure at MS-SPRING/BLSR port may cause Protection Switching
and Squelching due to invalid K-Bytes
In case of a short failure at an MS-SPRING/BLSR port, e.g. caused by a
protection switch on optical layer in a DWDM system, it may happen
that invalid, but acceptable K-bytes are injected into the MS-
SPRING/BLSR ring. These invalid K-bytes may start rotating through
the ring, if they contain an unknown Node ID.
Due to the mechanism to declare a SF condition if too many K-Byte
changes are detected in a certain period of time, further propagation of
the invalid K-bytes is stopped. However, the SF condition now triggers
MS-SPRING/BSLR protection switches and traffic squelching actions
(the SF may be declared by more than one node). After three seconds the
SF condition is cleared and the situation normalizes again.
Workaround:
Provision Extra Traffic in at least one of the ring nodes. This will prevent
to forward the invalid K-bytes.
Problem 11.1 - nb92701
Inconsistent state information for MS SPRING / BLSR ring entry/exit
points
Cross connections of MS SPRING / BLSR service traffic circuits have
attached state information for the ring entry point (loca) and the ring exit
point (locz). These states are called "locastate" and "loczstate". A cross
connection of an MS SPRING / BLSR ring circuit is considered
bidirectional if there are cross connections of the same rate for both
...............................................................................................................................................................................................................................................................
Known ProblemsKnown Problems
3 - 6 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
directions which have consistent loca and locz information. However,
the consistency of the locastate and loczstate information is not checked
for this purpose. For the case that ring entry and exit information is
manually provisioned (ED-PROTN-GRP parameter "asmc" = disabled),
the locastate and loczstate should always have the value "MANUAL-
VALID" if the entered TID is part of the ring map.
Nevertheless, cases of incorrect state values "MANUAL-INVALID"
have occurred. If this problem affects only one direction of a
bidirectional MS SPRING / BLSR cross connection then the result of
cross connection retrieval operations (RTRV-CRS) will become
inconsistent. Dependent on from which end the cross connection is
retrieved, the incorrect value of "MANUAL-INVALID" will become
visible or not.
Workaround:
Once occurred the problem of incorrect locastate or loczstate values can
be repaired by enabling automatic squelch map calculation in the
affected node and ring and disabling it later again (parameter "asmc").
Another option is to change the related TID value (loca or locz) forth and
back via the ED-CRS command. This will also cause to re-calculate the
locastate and loczstate.
Problem 10.5.5 - nb93083
SYSCOMF alarm may be an indicator for toggling LO-UPSR protections
if interface standard of NE is SONET.
If the input signals to LO-UPSR selectors are not stable and cause a lot
of LO-UPSR switches this may cause the system to enter an overload
state where it throttles the generation of LO-UPSR switch notifications.
If this state persists for some time and the system's interface standard
is set to SONET then a SYSCOMF alarm is raised as an indicator for this
state.
Therefore the operator should check whether the system is in an
overload state due to massive LO-UPSR switching. The output of the
TL1 command RTRV-OVLD may give further hints on LO tributaries
causing the notification load.
Workaround:
When a SYSCOMF alarm is raised and the interface standard is SONET
then first follow the trouble clearing procedure for the alarm
PROCROVLD before following that of SYSCOMF.
Known ProblemsKnown Problems
...............................................................................................................................................................................................................................................................
3 - 7Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
0Area Equipment
Protection
Problem 9.0.3 - nb87425
CTL reports CPFail due to slow synchronisation in very rare cases
It has been observed in very rare cases that after a reset of the standby
CTL, e.g. due to a Duplex CTL switch or a reset applied to the standby
CTL, the initial synchronisation of the CF-disk content takes place very
slow and does not complete with in 45 minutes. After this timeout a
CPFail alarm is reported for the standby CTL.
Workaround:
If a CPFail alarm is raised about 45 minutes after a duplex switch or after
resetting the standby CTL apply a Full Reset to the standby CTL. If the
CPFail alarm does not clear permanently the CPFail has a different root
cause and the CTL should be replaced.
0Area Fault/Alarm
Management
Problem 10.0.1 - nb90684
STM1 Port on OPLB with STM1/OC3 interface modules always uses the
default ASAP
In the case of an OPLB equipped and configured for STM1/OC3 ports
an assigned non default port ASAP will not be used. Instead always the
default ASAP is taken for severity calculation.
Workaround:
The only workaround possible is to modify the default ASAP for the
fault causes where a modification is required. If the defaults are required
for other ports a copy of this can be made for these ports and this copied
ASAP could be taken e.g. private ASAP Def1 for the other ports
requiring the original defaults.
Problem 10.0.1 - nb90703
OPLB used for STM1/OC3 Port capacity always uses the default ASAP for
path instances
In the case of an OPLB equipped and configured for STM1/OC3 port
capacity an assigned non default ASAP as e.g. PATH ASAP assigned to
a tributary of a port will not be used. Instead always the default ASAP is
taken for severity calculation.
...............................................................................................................................................................................................................................................................
Known ProblemsKnown Problems
3 - 8 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
Workaround:
The only workaround possible is to modify the default ASAP for the
fault-causes where a modification is required. If the defaults are required
for any other instances in the system a copy of this can be made for these
instances as e.g. path entities, and this copied ASAP could be taken
instead of the modified default. So e.g. create a private ASAP e.g. DEF1
as copy of the default , assign this for the instances in the system
requiring the original default, and modify the default ASAP to the
desired values.
0Area Performance
Monitoring
Problem 11.0 - nb87234
ES64U historical PM bins are lost after reboot of ES64U
After a reboot (also an upgrade to the next release) of the ES64U the
historical bin data for 15min and 24h data are lost.
Workaround:
Retrieve the historical data on a regular base if information is needed.
Problem 10.5 - nb86493
Failure Counters for DS3 and STS1 on TMUX2G5 count wrong
The Failure Counts FC-P and FC-PFE related to the DS3 termination
and STS1 termination at the asynchronous side of TMUX2G5 do not
count failure events as expected. Instead they count the seconds where a
failure is present.
E.g. when a LOS is detected and cleared after five seconds, FC-P is
expected to be incremented by 1. However, it actually is incremented by
five.
Workaround:
None.
Known ProblemsKnown Problems
...............................................................................................................................................................................................................................................................
3 - 9Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Problem 10.5 - nb89558
TMUX2G5: DS1 PM counter FC-P never incremented
The DS1 PM counter FC-P related to DS1 NIMs on TMUX2G5 is
always reported with a value of zero and is never incremented. The
reason is that it is currently not fully supported by the system.
Workaround:
None.
Problem 10.5 - nb89559 (nb86495)
Wrong DS1 PM counters on TMUX2G5 in case of DS1-LOF
When a TMUX2G5 detects a DS1-LOF condition the PM counters do
not correctly reflect this. The counter ES-P, SES-P, SAS-P and conse-
quently UAS-P are not incremented further as long as the LOF condition
is persistently present.
Workaround:
None.
0Area Packet Management Problem 11.01.27 - nb95084
ES64U: Inconsistent MAXMTU settings may lead to CARD_FAIL alarm
When the MAXMTU size for ports on ES64U is not configured
consistently this may result in an unexpected CPFAIL/CARD_FAIL
alarm being raised for the ES64U card.
This may happen under the following circumstances:
+ The MAXMTU of the ingress port is larger than the MAXMTU of the
egress port,
+ All traffic arriving at this ingress port has a frame length larger than
the MAXMTU if the egress port, such that the frames pass the MTU size
check of the ingress port but are dropped at the egress port.
...............................................................................................................................................................................................................................................................
Known ProblemsKnown Problems
3 - 1 0 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
+ Beside the ingress or egress port there is no other port existing on the
same GAUSS device, which carries traffic.
Workaround:
Ensure to consistently provision MAXMTU of ports being used as
ingress and egress ports of flows.
Problem 11.01.25 - nb94411 / nb94519
ES64U: UPSR switching times high when LCAS is enabled and LCAS-
HTMR=0
When the tribs of a VCG located on ES64U with LCAS being enabled
are protected by UPSR and a UPSR switch occurs it is expected that the
resulting traffic interruption time is less than 50 msec. However, if the
LCAS hold-off timer is set to 0 the observable traffic hits are below 50
msec with a probability of about 75%, about 20% have a duration of 3
seconds and the rest is somewhere in between.
When using an LCAS hold-off timer of 100msec then the traffic hit is
below 50 msec with a probability of about 95% with outliers of up to
about 3 seconds.
Workaround:
If VCG tribs are UPSR-protected set LCAS holdoff timer to 100msec or
higher.
Known ProblemsKnown Problems
...............................................................................................................................................................................................................................................................
3 - 1 1Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Problem 11.01.25 - nb94390 / nb94518
ES64U: EQP blocked on Reset of active ES64U when Forced Switch is
active
When applying a Forced Switch to the active ES64U and now resetting
the active ES64U card the ES64U will reboot as expected and become
operational again. However, the Equipment Protection Group will be
blocked, after clearing the forced switch further switch requests are
rejected, also autonomous switching is disabled.
This state is notified at the management interface with a Switch Request
State of EF for the equipment protection group and an Equipment Status
of EF for both ES64U packs.
Workaround:
To re-enable the equipment protection group again the standby ES64U
must be reset twice. After the first reset request the standby ES64U will
not become operational due to a failed synchronisation with the active
ES64U. Therefore another Reset is required, about 15 minutes after the
first one. Now the standby ES64U succeeds to synchronise and become
operational, the Switch request State and the Equipment Status changes
to NR.
Problem 11.01.25 - nb94442 / nb94449
ES64U: Clearing an LCAS WTR Timer not supported
When a member of a VCG located on ES64U with LCAS being enabled
is in a wait-to-restore state, i.e. a failure has cleared again, but the
member has not been activated again because the WTR timer is still
running, the operator should be able to terminate the WTR period using
the TL1 command OPR-VCGTRIB-STS. However, this command is
always rejected by the system with error code
SNVS /* Status, Not in Valid State, Tributary is not in state wait-to-
restore */
when applied to a VCGTrib on ES64U.
Workaround:
Disable and re-enable output membership of the VCGTrib to terminate
WTR period.
...............................................................................................................................................................................................................................................................
Known ProblemsKnown Problems
3 - 1 2 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
Problem 11.01.25 - nb94333
ES64U: No MND alarm if VCG member is removed because of too high
differential delay
When a VCG member of ES64U is removed by LCAS from the group
because its differential delay is too high related to the other VCG
members then, beside the PLCR alarm, a MND (Member Not
Deskewable) alarm is expected. However, due to the generic decision to
not support tributary related alarms on ES64U no MND is raised.
Workaround:
When a PLCR (Partial Loss of Capacity) alarm is raised for a VCG of
ES64U and membership provisioning is consistent at both ends of the
VCG then check for trib alarms on the related I/O pack to which the
VCG tributaries are cross-connected.
If the membership provisioning is consistent and there are no trib alarms
on the I/O packs then the root cause of the PLCR alarm is most likely a
differential delay that is too large for the failed ES64U VCG members.
Problem 11.01.25 - nb94345
ES64U: Disabling of VCG members in LCAS mode only hitless if waiting
long enough between the provisioning steps
When reducing the size of a VCG having LCAS enabled this is expected
to be hitless if following the correct order (disable source side (inmbs),
before sink side (outmbs)). However, for a VCG on ES64U it is also
required to wait for at least one second between the single provisioning
steps. E.g. when removing one trib bidirectionally from a VCG between
a GE10PL1 and an ES64U then
- disable inmbs at GE10PL1 and wait one second
- then disable inmbs at ES64U and wait one second
- then disable outmbs at GE10PL1 and wait one second
- then disable outmbs at ES64U.
Known ProblemsKnown Problems
...............................................................................................................................................................................................................................................................
3 - 1 3Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
When following these steps the trib removal is hitless.
Workaround:
Wait at least one second between the provisioning steps.
Problem 11.0 - nb87231
ES64U is not able to push vlan when the inflowclassifier has same vlan
The attempt to push for an ETS the same VLAN ID via CLI is denied, if
the inflowclassifier has this VLAN ID already.
Workaround:
Need to define different vlan tag on classifier or on push table - for the
same port
Problem 10.0 - nb83944 (nb83632)
Disabling of LCAS causes traffic hit which is longer than expected
When an Ethernet connection is set up and LCAS is disabled at one end
a traffic hit occurs which is longer than expected.
When disabling LCAS at the remote end of the VCG-trail while
GE10PL1 at the local end of the trail still has LCAS enabled traffic is
lost for a rather long period of time. Instead of a potential short hit
caused by the need to resort the members the following hit times
havebeen observed:
+ 1GbE connection
- VC4-7v/STS3c-7v: about 0.6 seconds
- STS1-21v: 0.7 to 1.1 seconds
+ 10GbE connection
- VC4-64v/STS3c-64v: 5.6 to 6 seconds
- STS1-192v: 45 to 49 seconds
...............................................................................................................................................................................................................................................................
Known ProblemsKnown Problems
3 - 1 4 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
When disabling LCAS at the remote end while LCAS is already disabled
locally at GE10PL1 only the potential expected short hit may occur
(proven only with GE10PL1 at both ends).
Workaround:
None.
Problem 8.0.1 - nb95033
GE10PL1: VCG member not declared failed on degraded
condition
When for a VCG member of GE10PL1 a degraded condition is detected
due to a high bit error rate, this is alarmed by a THPDEG alarm.
However, in case LCAS is enabled for this VCG, the degraded condition
does not lead to declaring the VCG member as failed, thus the member is
not removed from the VCG.
Under a degraded condition, however, the VCG member may be
removed due to other failures, e.g. if the LCAS and VCAT protocol
information transported in the H4 byte of the overhead has errors.
Workaround:
Remove a member manually when a THPDEG alarm is present.
0Area CIT Problem 11.01.28 - nb95142
No further support of BWM orTDM10G
Due to incompatibility of the Java versions it is not possible that BWM
or TDM10G will be supported by the CIT of R11.01.28.; So this support
is removed.
4 - 1Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
...............................................................................................................................................................................................................................................................
4 New Installation and Upgrade
Procedures
............................................................................................................................................................................................................................................................
Contents 0
General 4 - 4
Known Problems 4 - 4
updated PC requirements 4 - 4
Upgrade from Release 11.01.27, Release 11.01.26 or Release.11.1.11 to Release 11.01.28 4 - 4
Upgrade path survey 4 - 5
New Installation and Software Upgrade 4 - 6
Overview 4 - 6
To perform an initial NE software download 4 - 7
Purpose 4 - 7
Safety precautions 4 - 7
Before you begin 4 - 7
Instructions 4 - 8
NE Software Upgrade 4 - 12
To upgrade software to a new release 4 - 12
When to use 4 - 12
Before you begin 4 - 12
Prepare CompactFlash® card for fall back solution 4 - 13
Upgrade-preconditions for the Network Element 4 - 13
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 2 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
Upgrade-preconditions for the whole network 4 - 14
Instructions 4 - 15
To perform an NE software download for upgrade purposes 4 - 20
When to use 4 - 20
Download limitations 4 - 20
Related information 4 - 20
Before you begin 4 - 20
Instructions 4 - 21
To activate an NE software generic 4 - 26
When to use 4 - 26
Before you begin 4 - 27
Instructions 4 - 27
To check for successful NE software upgrade 4 - 32
When to use 4 - 32
Before you begin 4 - 32
Instructions 4 - 32
To solve NE software upgrade problems 4 - 33
When to use 4 - 33
Instructions 4 - 33
Trouble shooting procedure A 4 - 34
Trouble shooting procedure B 4 - 35
Trouble shooting procedure C 4 - 36
Trouble shooting procedure D 4 - 37
Trouble shooting procedure E 4 - 40
To retrieve NE software generic information 4 - 42
When to use 4 - 42
NE active software 4 - 42
Instructions 4 - 42
Supporting information for “Retrieving NE software generic information” 4 - 43
NE software display window 4 - 43
Elements of the NE software display window 4 - 43
Database backup 4 - 45
Overview 4 - 45
Purpose 4 - 45
To limit the number of saved backups 4 - 45
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 3Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Purpose 4 - 45
Before you begin 4 - 45
Instructions 4 - 45
Manually backup database to the WaveStar® CIT 4 - 47
When to use 4 - 47
Safety precautions 4 - 47
Related information 4 - 47
Before you begin 4 - 47
Instructions 4 - 48
To retrieve NE database information 4 - 51
When to use 4 - 51
Instructions 4 - 51
Supporting information for Retrieving NE database information 4 - 52
Elements of the Database Info window 4 - 52
To restore a database to a network element 4 - 54
Purpose 4 - 54
Safety precautions 4 - 54
Before you begin 4 - 54
Instructions 4 - 55
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 4 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
General 0
Known Problems When detecting problems check chapter 3 “Known Problems” of this
document for workarounds.
updated PC requirements The minimum PC configuration that supports the WaveStar-CIT
application:
• Pentium® 4 1.3 GHz or higher recommended.
• Minimum 1GB of RAM .
• 2 GB of free hard-disk drive space
• CD-ROM drive (16X recommended)
• CompactFlash® card device
• SVGA monitor set to minimum 1024x768 resolution, 16
million colors
• 100BaseT LAN interface, installed and working
Upgrade from
Release 11.01.27, Release
11.01.26 or Release.11.1.11
to Release 11.01.28
The Upgrade Software for upgrading an existing
1675.LambdaUnite®.MSS system with Release 11.01.27, Release
11.01.26 or Release.11.1.11 to Release 11.01.28, consists of two parts:
• 1675.LambdaUnite®.MSS Network Element (NE) Software
Version 11.01.28
• WaveStar®.CIT (Craft Interface Terminal) Software
Release.18.09.05 Build.5091
delivered on a CD-ROM (Comcode 109792648 or 109792671
downloadable version).
The WaveStar®.CIT only CD-ROM (Comcode 109799296 or
109799304 downloadable version) does not contain the
1675.LambdaUnite®.MSS Network Element (NE) Software Version
11.01.28, but only the WaveStar®.CIT (Craft Interface Terminal)
Software Release.18.09.05 Build.5091.
The software for the 1675.LambdaUnite®.MSS NE is loaded into the
CTL/memory pack of the shelf via the CompactFlash® card. The
software for the WaveStar®.CIT is installed onto a (Microsoft®
Windows XP® based) PC configured with an Ethernet LAN card. The
procedure for loading both packages is provided below.
Additionally a survey of upgrade paths is embodied in this chapter.
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 5Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Upgrade path survey 0
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 6 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
New Installation and Software Upgrade 0
Overview
This chapter describes both
• the procedures which have to be carried out for the first installation
and
• the procedures for the software upgrade of the
1675.LambdaUnite®.MSS.
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 7Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
To perform an initial NE software download 0
Purpose Use this procedure to install a software generic in the NE for the first
time.
The software is initially delivered to the customer on a CD-ROM
(Comcode 109792630 or 109792663 downloadable version). The
software generic has to be copied from the CD-ROM to the
WaveStar®.CIT PC and then to the empty CompactFlash® card via
WaveStar®.CIT. Afterwards, the CompactFlash® card is inserted into the
NE.
Safety precautions
Electronic components can be destroyed by electrostatic discharge.
Circuit packs must therefore always be kept in antistatic covers. Use the
original antistatic packaging if possible. Always observe the ESD
instructions.
CAUTION
Improper removal of a CompactFlash® card can result in damaged files
and the generation of information messages such as “lost clusters”
and/or “missing/damaged sectors”.
Be very cautious and follow the specific instructions when handling
CompactFlash® cards.
To assure both personal safety and the proper functioning of the
1675.LambdaUnite®.MSS product, it is imperative to observe the
preceding precautions.
Before you begin Prior to performing this task, you must:
1. Acquire the CD-ROM that contains the new generic/version of the
NE software (Comcode 109792630).
Required equipment
The following equipment is required to perform this task:
• Empty CompactFlash® card (the required storage capacity depends
on the used Controller)
• CD-ROM that contains the new generic/version of the NE software
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 8 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
• WaveStar®.CIT PC with CompactFlash or PCMCIA slot. For the
second case an adapter is required.
Instructions To initially download the NE software (delivered on a CD-ROM)
proceed as follows:
..................................................................................................................
1. Power up the WaveStar®.CIT PC and log into Windows XP® as
administrator. If you are already logged in, close any open window.
..................................................................................................................
2. Install the NE software on your PC. To do this, use one of the
following two methods (automatic or manual installation).
..................................................................................................................
3.
..................................................................................................................
4. Insert the LambdaUnite® CD-ROM with the new NE software.
..................................................................................................................
5.
..................................................................................................................
6. Click Continue.
IF THEN
You use the automatic
installation method
proceed with the next step.
You use the manual
installation method
proceed with Step 11
IF THEN
the Welcome Screen
appears,
proceed to Step 6
the Welcome Screen does
not appear,perform the following:
1. Go to the Start button.
2. Click Start with the right mouse
button and select Explore.
3. Select the drive that corresponds to
your CD-ROM.
4. Double click the setup.exe file in
the root directory of your CD-
ROM drive.
5. Proceed to Step 6.
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 9Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
..................................................................................................................
7. Choose the NE Software entry.
..................................................................................................................
8. Click the NE Software button on the right.
..................................................................................................................
9. Wait for the software transfer to complete.
NOTE: You will notice that the “Copying files, please wait ...”
message and also the InstallShield Wizard disappears when this
operation has completed.
..................................................................................................................
10. Click Exit.
Continue with Step 19.
..................................................................................................................
11. Manual Installation: Insert the 1675.LambdaUnite®.MSS CD-ROM
with the new NE software. If the welcoming screen appears, select
Cancel to exit from the automatic installation procedure.
..................................................................................................................
12. Open the Windows Explorer on your desktop.
..................................................................................................................
13. Select the hard disk drive where WaveStar®.CIT is installed (in
most cases C:) and click through to Program Files --> Alcatel-
Lucent --> WaveStar CIT --> generics or Program Files -->
Lucent Technologies --> WaveStar CIT --> generics.
Please note that, if the subdirectory generics does not exist, you
must create it!
..................................................................................................................
14. In the generics directory, create a new folder, preferably stating the
new software version in its name.
..................................................................................................................
15. In the Windows XP® Explorer, right-click the CD-ROM drive of
your computer and select Explore. Go to the generics directory.
This directory contains two subdirectories: p and up.
..................................................................................................................
16. Select the complete up and p directories and copy it to the folder
you created in Step 14.
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 1 0 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
..................................................................................................................
17. To install Acrobat Reader on your system, go to the Acrobat Reader
subdirectory on your CD-ROM drive and double-click the
AcrobatReader40.exe file.
..................................................................................................................
18. The Software Release Description (SRD) is located in the
Documentation subdirectory of the CD. You can read it by double-
clicking the .pdf file in this subdirectory.
..................................................................................................................
19. Insert the empty CompactFlash® card into the CompactFlash® slot
(or PCMCIA slot with adapter) of the WaveStar®.CIT PC.
..................................................................................................................
20. Start WaveStar®.CIT.
..................................................................................................................
21. In the WaveStar®.CIT Main Window, choose the option
Administration --> Prepare PCMCIA Disks
Result: The Prepare PCMCIA Disk window appears.
..................................................................................................................
22. In the left list, under Available Generics, click the version of
network element software you are installing.
..................................................................................................................
23. In the right list, click on the drive letter that represents the
CompactFlash® card.
Result: A WaveStar®.CIT error message is displayed.
..................................................................................................................
24. Click on OK.
Important! If the error message window is not closed
automatically after clicking OK then click on the close button (x) in
the upper right corner of the window.
..................................................................................................................
25. Click on Copy Generic.
Result: The file copy function starts and you see a Copying files
message.
..................................................................................................................
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 1 1Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
26. The “Copying files...” message will disappear when the file transfer
is complete. Click the Close button to exit the Prepare PCMCIA
Disk window.
..................................................................................................................
27. If the CompactFlash® card driver software you are using requires
you to stop the CompactFlash® card before ejecting it, stop the card
now. If the software you are using does not allow for this
procedure, make sure that the used slot is not being accessed (the
LED is not blinking) before continuing.
..................................................................................................................
28. Eject the CompactFlash® card from the CompactFlash® slot (or
PCMCIA slot with adapter) of the WaveStar®.CIT PC.
..................................................................................................................
29. Insert the CompactFlash® card with the new software version into
the CTL circuit pack. Please observe the ESD instruction.
To do this
• insert the CompactFlash® card (red arrow on card down and
facing left)
• close and fix the protecting bar.
Result: The CTL circuit pack is now prepared for insertion
into the system.
............................................................................................................................................................E N D O F S T E P S
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 1 2 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
NE Software Upgrade 0
To upgrade software to a new release
When to use Use this procedure to upgrade to a new release of the NE software.
This procedure describes a non-traffic-affecting field upgrade of the
1675.LambdaUnite®.MSS software from a former release to Release
11.01.28.
After a software generic has successfully been loaded onto the NE and is
activated with the option TRIAL, it is possible to revert back to the
previous generic together with the restoration of the last matching
database. Upgrading with option TRIAL (and downgrading with
REVERT) is only supported for non-ONNS (traditional) NEs. This
functionality is called Software Downgrade.
Important! A SW upgrade should be performed by trained person-
nel only.
Before you begin Prior to performing this task, you must:
1. Have a valid login on both the WaveStar®.CIT and all subject
NE(s).
2. Acquire the CD-ROM that contains the new generic/version of the
NE software.
3. Connect the WaveStar®.CIT locally to the subject NE.
4. Make sure that there is no configuration (write) access to the NE
from other WaveStar®.CITs or management systems during the
software download. During the upgrade procedure, starting with the
database backup until the complete error free start up of the new
release, the following must be avoided:
• provisioning, including provisioning in other parts of the net-
work (e.g. BLSR rings)
• changing cables,
• changing HW,
• replacing defect HW.
5. Make sure that there are no fault situations in DNI/DRI
configurations to avoid unintended protection switches.
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 1 3Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Prepare CompactFlash®
card for fall back solution
Prepare a CompactFlash® card for a “fall back” solution (in case the NE
software is not successful) with the currently used NE software. Please
refer to the 1675.LambdaUnite®.MSS Installation Guide.
Depending on the application a CompactFlash® card of the following
size has to be used:
• 1-GByte (for applications with CTL/3T or CTL/3S), Comcodes
109558544 or for the new version 109763557.
Important! In case of duplex control, it is also possible to plug out the
standby CTL and use the CompactFlash® card of the standby CTL for
the “fall back” solution. The upgrade will be performed in the simplex
control mode in this case. After successful completion of the upgrade the
second CTL can be inserted again in order to establish the duplex control
mode.
Upgrade-preconditions for
the Network Element
The following preconditions have to be fulfilled by the NE to be
upgraded:
• Prior to an upgrade any alarm OMUNSUP, OMMISMA, OMFAIL
present for ports on GE10PL1 needs to be cleared to avoid potential
permanent traffic loss after the upgrade.
• All alarms on the NE (e.g. alarm list, UPL) are cleared. If it is not
possible to clear all alarms the cause for the remaining alarms must
be fully understood and clear.
• All protection switches (SNCP; MS-SPRING; MSP) should work
in idle/no switch state.
• The ring maps (DCCEI) for all configured MSSPRING/ BLSR
rings are available.
• Protection switches (e.g. equipment protection, traffic protection)
should be avoided during the upgrade.
• Activation of a new SW generic or a newly downloaded DB is only
possible if the NVM of standby the CTL is reliably accessible:
When the NVM (i.e. the CF-disk) of the standby CTL is not reliably
accessible from the active CTL while trying to activate a SW
generic or a database previously downloaded this activation request
is rejected. This behavior is implemented to ensure that such a
standby CTL having a somewhat indefined NVM state cannot take
over in the course of the reset being applied to the active CTL on
SW/DB activation.
If this precondition is not given, then:
- First it should be tried to bring back the standby CTL into a better
state by applying a Full Reset to the standby CTL and waiting
whether it succeeds to start synchronisation.
- If after five minutes the SW/DB activation request is still rejected
then on-site action is necessary.
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 1 4 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
- The standby CTL must be pulled from the system and the SW/DB
activation can be done in simplex mode. Alternatively it can be
tried to bring the standby CTL into a proper state again by replacing
either CF-disk or the complete CTL including the CF-disk.
Upgrade-preconditions for
the whole network
The following preconditions have to be fulfilled by the other
1675.LambdaUnite®.MSS NEs, which are included in the same network:
• A checklist of all NSAP addresses of the 1675.LambdaUnite®.MSS
NEs, to be updated in the network, must exist
• During the upgrade all 1675.LambdaUnite®.MSS NEs in this
network must run the same old NE software version or already the
new NE software.
• It is strongly recommended not to use the new features and
extended features of the new release, until the complete upgrade of
the whole network is achieved.
Possible traffic loss in a Spanning Tree network when rebooting two
GE1 port units in parallel
When resetting in parallel (or shortly after each other) two bridges,
which belong to the same spanning tree, the traffic which is routed
through these two bridges and an adjacent one is likely to be dropped on
the reset of the second bridge until this one is operational again.
However, such a scenario of resetting two bridges in parallel is unlikely
to occur:
• If the bridges are located in different NEs the main reason to reset
both in parallel is a software upgrade within the network. It is
expected that such a software upgrade is done NE by NE, i.e.
upgrading and rebooting one NE before starting with the next one.
• If the bridges are located in the same NE then during a software
upgrade it is very likely that both are reset in parallel. However, the
traffic would only be dropped if it would be routed through both
bridges, i.e. in scenarios where several bridges are cascaded to build
a bigger switch having more LAN and/or WAN ports.
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 1 5Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Required equipment
The following equipment is required for upgrading the
1675.LambdaUnite®.MSS software from a former release to Release
11.01.28:
• Software for 1675.LambdaUnite®.MSS, Release 11.01.28.
• Software for 1675.LambdaUnite®.MSS, former release (used for
“Fall Back” solution). That means, in accordance with the allowed
upgrade path, exactly the release that comes before the release, to
which the NE should be upgraded.
• An empty CompactFlash® card (the required storage capacity
depends on the used Controller)
Depending on the application:
– a spare 1 GB CompactFlash® card, Comcodes 109558544 or
for the new version 109763557 (for applications with CTL/3T
or CTL/3S)
– and the opposite CompactFlash® adapter.
• a WaveStar®.CIT PC with CompactFlash or PCMCIA slot. For the
second case an adapter is required.
To avoid interworking problems during the upgrade, which starts
with the old release and ends with the new release, the
WaveStar®.CIT shall support both versions.
• 10 Mbit Hub (recommended).
Important! In configuration with 100Mbit LAN cards, sometimes
the transmission link can not be established. For that cases, insert a
10Mbit Hub in the physical link between the PC (with installed
WaveStar®.CIT software) and one of the supported Ethernet LAN
ports of the 1675.LambdaUnite®.MSS (i.e. LAN1 on the User panel
or LAN2 or LAN3 on the CICTL).
The following Hubs are tested with 1675.LambdaUnite®.MSS
– Hewlett Packard J3128A/ Advanced Stack Hub-8E
– Allied Telesyn MR820TR
– Allied Telesyn 3024SL
– Allied Telesyn MR815T
– Allied Telesyn MR415T
• Ethernet LAN cables
Important! Two straight cables are required when using a hub. A
crossover cable is required when connecting directly from
WaveStar®.CIT to the NE.
Instructions Complete the following steps to update the NE with a new software
release.
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 1 6 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
..................................................................................................................
1. Upgrade the WaveStar®.CIT software.
..................................................................................................................
2. Power up the WaveStar®.CIT PC and log into Windows XP® as
administrator. If you are already logged in, close any open window.
..................................................................................................................
3. Download the software for the new release. Refer to “To perform
an NE software download for upgrade purposes”
..................................................................................................................
4. Perform a database backup. Refer to “Manually backup database to
the WaveStar® CIT”
..................................................................................................................
5. Activate the SW for the new release. Refer to “To activate an NE
software generic”
..................................................................................................................
6. Check if new software generic has been activated. Refer to “To
retrieve NE software generic information”
............................................................................................................
7. Check if the upgrade was successful.
Check the following:
• Remote management access is possible, as before the upgrade.
• No unexpected changes in the alarm states occurred.
Changes in the alarm states may be caused by newly introduced
system functions. Therefore any change in the alarm states need to
be checked thoroughly.
..................................................................................................................
8.
IF THEN
the upgrade was successful, The upgrade is complete and the
system works with the new release
SW.
End of Steps
the upgrade was not
successful and the system is
running with the old
software,
End of Steps
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 1 7Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
..................................................................................................................
9. The following steps are to be used to perform a fallback to the old
release after an unsuccessful SW upgrade.
In case of duplex control the standby CTL has to be removed before
the active CTL is plugged out.
..................................................................................................................
10. Plug out the active CTL and remove the CompactFlash® card.
..................................................................................................................
11. Insert the CompactFlash® card (either a new one or the one
removed from LambdaUnite® CTL) into the CompactFlash® slot
(or PCMCIA slot with adapter) of the WaveStar®.CIT PC.
Additional info: If you are using a used CompactFlash® card at
first you have to empty it by using the Windows® Explorer. Do not
format the CompactFlash® card.
..................................................................................................................
12. Start WaveStar®.CIT.
..................................................................................................................
13. Copy the old release SW stored on the WaveStar®.CIT onto the
CompactFlash® card. In the WaveStar®.CIT Main Window, choose
the option Administration --> Prepare PCMCIA Disks.
Result: The Prepare PCMCIA Disk window appears.
..................................................................................................................
14. In the left list, under Available Generics, click the version
(previous SW generic) of network element software you are
installing.
..................................................................................................................
15. In the right list, click on the drive letter that represents the
CompactFlash® card.
Result: A WaveStar®.CIT error message is displayed mentioning
that “The device you have selected is not blank”.
..................................................................................................................
the upgrade was not
successful and the system is
inoperable (e.g. cyclic
reboot),
perform a fall back to the old release,
proceed with Step 9
IF THEN
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 1 8 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
16. Click on OK.
Important! If the error message window is not closed automati-
cally after clicking OK then click on the close button (x) in the
upper right corner of the window.
..................................................................................................................
17. Click on Copy Generic.
Result: The file copy function starts and you see a Copying files
message.
..................................................................................................................
18. The “Copying files...” message will disappear when the file transfer
is complete. Click the Close button to exit the Prepare PCMCIA
Disk window.
..................................................................................................................
19. If the CompactFlash® card driver software you are using requires
you to stop the CompactFlash® card before ejecting it, stop the card
now. If the software you are using does not allow for this
procedure, make sure that the used slot is not being accessed (the
LED is not blinking) before continuing.
..................................................................................................................
20. Eject the CompactFlash® card from the CompactFlash® slot (or
PCMCIA slot with adapter) of the WaveStar®.CIT PC.
..................................................................................................................
21. Insert the CompactFlash® card with the old SW and the empty
database into the plugged out CTL.
..................................................................................................................
22. Make sure that the CompactFlash® card is firmly seated in the CTL.
..................................................................................................................
23. Insert the CTL.
Result: The system starts to activate the old SW generic and comes
up in the maintenance mode.
Note that the CompactFlash® card has to remain in the CTL circuit
pack during normal operation (normal operation comprises the
maintenance mode).
..................................................................................................................
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 1 9Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
24. Restore the database backup which was made before the upgrade
via local WaveStar®.CIT (connected via LAN1 of the NE). Refer to
“To restore a database to a network element”.
Result: Fall-Back complete. System up again with old release SW.
Important! The GE1 packs might hang up in recovery and a
Circuit Pack Comm Failure (CPCOMF) alarm might be raised for
those packs.
To bring them back to operation up to two Controller Resets of the
GE1 packs might be necessary.
In Repeater mode traffic is not affected. In switched modes traffic is
affected until the GE1 pack is operational again as protocols like
Spanning Tree Protocol (STP) and Generic Attribute Registration
Protocol VLAN Registration Protocol (GVRP) are not working.
..................................................................................................................
25.
..................................................................................................................
26. When the system is up again with the old release, delete the content
on the CompactFlash® card of the standby CTL by using the
Windows® Explorer. Do not format the CompactFlash® card.
..................................................................................................................
27. Insert the standby CTL, after the first CTL has completely
recovered.
............................................................................................................................................................E N D O F S T E P S
IF THEN
a standby CTL (duplex
control) is used,continue with the next steps.
no standby CTL is used, Stop! You have completed this
procedure.
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 2 0 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
To perform an NE software download for upgrade purposes
When to use Use this procedure to download a new version of the NE software
generic. A prerequisite for this is that a software generic (the predecessor
release) is already available in the NE. If this is not the case, please refer
to the task “To perform an initial NE software download”.
Important! This procedure has to be performed for all NEs within
the network.
Download limitations The number of parallel SW downloads from one WaveStar®.CIT is
limited to 5 parallel downloads.
A SWDL will not be possible if the NE in the trial phase (PRESERVED
state)
If a user tries to invoke a SW download from a WaveStar®.CIT while
there are already 5 SW downloads in progress from the same
WaveStar®.CIT, then the CPY-MEM command is denied with the error
code SROF - Status, Requested Operation Failed.
Related information Important! Do not remove or reset the standby (inactive) CTL
while a software download or database restoration is in progress.
Otherwise, the software download or database restoration will be
aborted.
Important! It is not possible to download the R11 SW image, if the
route of the SW download through the DCN involves RS-DCCs.
The SW download will fail with SROF error message. Try to con-
figure the DCN, that only MS-DCCs are used, or perform the SW
download locally via CIT at LAN port.
Before you begin Prior to performing this task, you must:
1. Have a valid login on both the WaveStar®.CIT and all subject
NE(s).
2. Acquire the CD-ROM that contains the new generic/version of the
NE software.
3. Connect the WaveStar®.CIT to the local area network (LAN) of the
subject NE.
Required privilege code
You must have at least a privilege code of S4.
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 2 1Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Required equipment
The following equipment is required to perform this task:
• WaveStar®.CIT
Please make sure that you always use the WaveStar®.CIT version
corresponding to the NE release you are upgrading to. If not yet
done, install WaveStar®.CIT on your PC (cf. WaveStar®.CIT
Tutorial).
• For SW download from the WaveStar®.CIT to the system via LAN
connections using a hub the following hubs are recommended:
– Hewlett Packard:
J3128A / Advanced Stack Hub-8E
– Allied Telesyn:
MR820TR
3024SL
MR815T
MR415T
Instructions Complete the following steps to download a new version of the NE
software generic.
..................................................................................................................
1. Power up the WaveStar®.CIT PC and log into Windows XP® as
administrator. If you are already logged in, close any open window.
..................................................................................................................
2. Install the NE software on your PC. To do this, use one of the
following two methods (automatic or manual installation).
..................................................................................................................
3.
..................................................................................................................
4. Insert the LambdaUnite® CD-ROM with the new NE software.
..................................................................................................................
IF THEN
You use the automatic
installation methodproceed with the next step.
You use the manual
installation
proceed with Step 11
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 2 2 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
5.
..................................................................................................................
6. Click Continue.
..................................................................................................................
7. Choose the NE Software entry.
..................................................................................................................
8. Click the NE Software button on the right.
..................................................................................................................
9. Wait for the software transfer to complete.
NOTE: You will notice that the “Copying files, please wait ...”
message and also the InstallShield Wizard disappears when this
operation has completed.
..................................................................................................................
10. Click Exit.
END OF AUTOMATIC INSTALLATION PROCEDURE
..................................................................................................................
11. Manual Installation: Insert the 1675.LambdaUnite®.MSS CD-ROM
with the new NE software. If the welcoming screen appears, select
Cancel to exit from the automatic installation procedure.
..................................................................................................................
IF THEN
the Welcome Screen
appears,proceed to Step 6.
the Welcome Screen does
not appear,perform the following:
1. Go to the Start button.
2. Click Start with the right mouse
button and select Explore.
3. Select the drive that corresponds to
your CD-ROM.
4. Double click the setup.exe file in
the root directory of your CD-ROM
drive.
5. Proceed to Step 6.
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 2 3Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
12. Open the Windows XP® Explorer on your desktop.
..................................................................................................................
13. Select the hard disk drive where WaveStar®.CIT is installed (in
most cases C:) and click through to Program Files --> Alcatel-
Lucent --> WaveStar CIT --> generics.
Please note that if the subdirectory generics does not exist, you
must create it!
..................................................................................................................
14. In the generics directory, create a new folder, preferably stating the
new software version in its name.
..................................................................................................................
15. In the Windows XP® Explorer, right-click the CD-ROM drive of
your computer and select Explore. Go to the generics directory.
This directory contains two subdirectories: p and up.
..................................................................................................................
16. Select the complete up and p directories and copy it to the folder
you created in Step 14.
..................................................................................................................
17. To install Acrobat Reader on your system, go to the Acrobat Reader
subdirectory on your CD-ROM drive and double-click the
AcrobatReader.exe file.
..................................................................................................................
18. The Software Release Description (SRD) is located in the
Documentation subdirectory of the CD. You can read it by double
clicking the .pdf file in this subdirectory.
..................................................................................................................
19. Log into the WaveStar®.CIT.
..................................................................................................................
20. At the WaveStar®.CIT, connect to the network element.
..................................................................................................................
21. From the WaveStar®.CIT System View, select the Configuration
--> Software --> Download Software menu option.
Result: The Download Generic window appears.
..................................................................................................................
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 2 4 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
22. According on how the NE is connected to the WaveStar®.CIT
select the responding option in the Download From/Via drop
down list box
23. Click the Download push-button.
Result: The software download is started.
In case of successful starting, a progress indicator window appears.
The NE will be provisionable during this generic download is in
process.
IF THEN
the WaveStar®.CIT is
connected to the NE via
DCC or OSI LAN
in the Download From/Via drop
down list box select CIT
A file selection screen appears
showing that the software will
downloaded from Program Files -->
Alcatel-Lucent --> WaveStar CIT --
> generics or Program Files -->
Lucent Technologies --> WaveStar
CIT --> generics. The directory of
the file selection screen is
automatically pre-populated.
In the file selection window, double
click the version of network element
software you are upgrading to (i.e. if
manual installation has been done, the
name of the folder you created in Step
14), double click the p directory.
the WaveStar®.CIT is
connected to the NE via
TCP/IP
in the Download From/Via drop
down list box select FTTD.
Enter the required parameters.
Specify the Source directory path as
follows:
generics/Wavestar_UNITE/<version
of network element software>/p.
the download of the software
generic shall be performed
using FTAM,
n the Download From/Via drop
down list box select FTAM.
Enter the required parameters.
Specify the Source directory path.
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 2 5Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
..................................................................................................................
24. Important! TCP/IP connections are aborted automatically after 60
minutes of inactivity (an “inactive TCP/IP connection” is a TCP/IP
connection over which no TL1 messages are transmitted in either
direction).
To avoid the behavior described before during the current software
download, if the WaveStar®.CIT is connected to the NE via a
TCP/IP, perform an action like clicking on the Update Alarms but-
ton in the system view. This causes TL1 messages (RTRV-ALM-
ALL, RTRV-ALM-ENV) to be sent to the NE.
..................................................................................................................
25. To check whether the download was successful, select View -->
Software Generic --> All Info from the NE System View menu
bar.
Result Two loads are displayed: Previous and Current.
..................................................................................................................
26.
............................................................................................................................................................E N D O F S T E P S
IF THEN
the download was
successful,Nothing to do.
Result: The new software generic is
now available in the “PREVIOUS”
area of the NE’s non-volatile memory
(NVM). It is not yet activated.
Reference: For activating the new
software, please refer to the task “To
activate an NE software generic”.
the download was
interrupted,Wait for about 10 minutes.
After 10 minutes the NE has
recovered from the last action and a
new download can be executed
Reference: Continue with Step 20.
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 2 6 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
To activate an NE software generic
When to use Use this procedure to activate a downloaded new version of an NE
software generic.
Important! Observe the following important details:
Duplex control Activation of a new SW generic or a
newly downloaded DB is only possible if
the NVM of the standby CTL is reliably
accessible: When the NVM (i.e. the CF-
disk) of the standby CTL is not reliably
accessible from the active CTL while
trying to activate a SW generic or a
database previously downloaded this
activation request is rejected. This
behavior is implemented to ensure that
such a standby CTL having a somewhat
indefined NVM state cannot take over in
the course of the reset being applied to the
active CTL on SW/DB activation.
If this precondition is not given, then:
- First it should be tried to bring back the
standby CTL into a better state by applying
a Full Reset to the standby CTL and
waiting whether it succeeds to start
synchronisation.
- If after five minutes the SW/DB
activation request is still rejected then on-
site action is necessary.
- The standby CTL must be pulled from
the system and the SW/DB activation can
be done in simplex mode. Alternatively it
can be tried to bring the standby CTL into
a proper state again by replacing either CF-
disk or the complete CTL including the
CF-disk.
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 2 7Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Before you begin Prior to performing this task, you must:
1. Have a valid login on both the WaveStar®.CIT and all subject
NE(s) within the ring.
2. Connect the WaveStar®.CIT to the local area network (LAN) of the
subject NE/ring.
3. Have performed a software download to the non-volatile memory
of the NE before.
Required privilege code
You must have at least a privilege code of S4.
Required equipment
The following equipment is required to perform this task:
• WaveStar®.CIT
Instructions Complete the following steps to activate/install a new/other version of
the NE software generic.
..................................................................................................................
1. Log into the WaveStar®.CIT.
..................................................................................................................
Software downgrade Only supported for non ONNS NEs and
PRESERVED state.
After a software generic has successfully
been loaded onto the NE it is possible to
revert back to the previous generic
together with the restoration of the last
matching database. This functionality is
called Software Downgrade. Therefore,
the system provides in addition an
alternative function to activate the new
generic with the option that an operator
may revert back to the previous generic
together with the restoration of the last
matching database.
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 2 8 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
2. At the WaveStar®.CIT, connect to the network element where you
want to activate the software currently located in the “PREVIOUS”
area of the non-volatile memory (NVM). The previous software
store should have the state DOWNLOADED (refer to “To retrieve
NE software generic information”.
..................................................................................................................
3. If STM-1 electrical interfaces in combination with 1+1 protecting
paddle boards are present in the NE execute a forced switch to the
active STM-1e pack to avoid a short traffic interruption
..................................................................................................................
4. In the WaveStar®.CIT System View, select the menu option
Configuration --> Software --> Activate Software.
Result: The Software Generic Install window appears. The win-
dow shows the currently inactive software generic in the “PREVI-
OUS” area of the non-volatile memory. Select the generic in the
list.
The group box Available Generics show the data of the PREVI-
OUS Generics.
..................................................................................................................
5. Using the group box Switch type you can select which type of SW
switch to perform
..................................................................................................................
6. Click OK.
Result: A confirmation window appears.
..................................................................................................................
7. If you are sure you want to activate the software, confirm by
clicking Yes.
Result: Several non traffic affecting system resets will be initiated
and communication to the NE will be lost during that time. During
the NE software upgrade, also a secondary boot upgrade take place.
IF YOU WANT TO THEN SELECT
install a downloaded SW
generic, Install
cause the downloaded
software to be installed in a
trial phase,
Trial
Only supported for non ONNS NEs.
During the trial phase, it is possible to
switch back to the previously
installed software and database. Prior
to installation, the software state must
be equal to DOWNLOADED.
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 2 9Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
This process might need about 1 hour.
Important! The resulting reboot of the GE10PL1 is not hitless
under all circumstances. Instead a traffic loss in the range of sec-
onds is observed. For details see the upg, Procedure 4-28 part "Pro-
visioning a VCG port for private line applications".
..................................................................................................................
8.
..................................................................................................................
9. In the WaveStar®.CIT System View, select the menu option
Configuration --> Software --> Activate Software.
..................................................................................................................
10. Using the group box Switch type you can select which type of SW
switch to perform
IF YOU THEN
installed software in normal
mode (SW switch type:
Install).
the procedure is ended!
installed software in trial
mode, and don’t want to
terminate the trial phase,
the procedure is ended!
installed software in trial
mode, and want to terminate
the trial phase,
continue with the next step.
IF YOU WANT TO THEN SELECT
terminate the trial phase of a
newly installed software.
Commit
Only supported for non ONNS NEs.
When the trial phase is terminated, a
switch back to the previously
installed software and database is no
longer possible. The termination of
the trial phase is allowed with the
PRESERVED state of the previous
SW generic and the previous
database.
force the system to switch
back to the previously
installed software and
database, during trial phase,
Revert
Only supported for non ONNS NEs.
Revert is only allowed if the NE is in
the PRESERVED state.
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 3 0 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
..................................................................................................................
11. Click OK.
Result: A confirmation window appears.
..................................................................................................................
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 3 1Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
12. If you are sure you want to activate the software, confirm by
clicking Yes.
Result: Several non traffic affecting system resets will be initiated
and communication to the NE will be lost during that time. During
the NE software upgrade, also a secondary boot upgrade take place.
This process might need about 1 hour.
Important! The resulting reboot of the GE10PL1 is not hitless
under all circumstances. Instead a traffic loss in the range of sec-
onds is observed. For details see the UPG, chapter 4.
Important! When upgrading a LambdaUnite node equipped with
GE1 packs using the trial mechanism and falling back to the old
release, the GE1 packs might hang up in recovery and a Circuit
Pack Comm Failure (CPCOMF) alarm might be raised for those
packs.
To bring them back to operation up to two Controller Resets of the
GE1 packs might be necessary.
In Repeater mode traffic is not affected. In switched modes traffic is
affected until the GE1 pack is operational again as protocols like
Spanning Tree Protocol (STP) and Generic Attribute Registration
Protocol VLAN Registration Protocol (GVRP) are not working.
For details see the MTCG, chapter 3.
............................................................................................................................................................E N D O F S T E P S
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 3 2 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
To check for successful NE software upgrade
When to use Use this procedure to check if NE software upgrade to new release was
successful.
Before you begin Prior to performing this task, you must:
1. Have a valid login on both the WaveStar®.CIT and all subject
NE(s) within the ring.
2. Connect the WaveStar®.CIT to the local area network (LAN) of the
subject NE/ring.
Required equipment
The following equipment is required to perform this task:
• WaveStar®.CIT
Instructions Complete the following steps to check the software upgrade to new
release was successful.
..................................................................................................................
1. Log into the WaveStar®.CIT.
..................................................................................................................
2. Check if traffic is working properly.
..................................................................................................................
3. Check if the system is working in normal mode.
..................................................................................................................
4. Check if the NE is running in Release 11.01.28 (The current version
is mentioned in the title bar of the System View window).
..................................................................................................................
5. Check if there are no new unexpected alarms on the shelf.
..................................................................................................................
6. Check if synchronization is locked to the correct timing source.
..................................................................................................................
7. Check if no protection switches took place.
.................................................................................................................
8. Verify the LED status on the front of the packs (CTL(s), XCs, OPs,
EPs).
.................................................................................................................
9. Verify the date and time of the NE and correct it if necessary..
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 3 3Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
..................................................................................................................
10. If STM-1 electrical interfaces in combination with 1+1 protecting
paddle boards are present in the NE, clear the forced switch to the
active STM-1e pack (the forced switch to the active STM-1e pack
has been executed during execution of the “To activate an NE
software generic”).
..................................................................................................................
11. It is recommended to perform a first database backup of all
successfully upgraded NE(s) now, since all former backups can not
be restored in Release 11.01.28.
............................................................................................................................................................E N D O F S T E P S
E N D O F S T E P S
To solve NE software upgrade problems
When to use Use this procedure to solve NE software upgrade problems.
Instructions ..................................................................................................................
1. If a Circuit Pack Comm Failure (CPCOMF) alarm is raised for a
circuit pack after software activation, then please refer to the
1675.LambdaUnite®.MSS Alarm Messages and Trouble Clearing
Guide for the respective trouble clearing procedure. Traffic is not
affected.
..................................................................................................................
2. If the NE shows strange behavior after software activation (for
example: login to NE not possible), then proceed as follows,
depending on the shown NE behavior after software activation:
Current NE behavior Trouble
shooting
Resulting NE behavior
A NE in simplex control:
• Login to NE not
possible
• No traffic lost
• Green activity LED on
the CTL is still flashing
1 hour after software
activation.
Please refer to
“Trouble
shooting
procedure A”.
Login to NE is possible
again (in case of no
success, refer to
“Trouble shooting
procedure E”).
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 3 4 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
Trouble shooting
procedure A
Electronic components can be destroyed by electrostatic discharge.
B NE in duplex control:
• Login to NE possible
• No traffic lost
• Green activity LED on
one CTL is still
flashing 1 hour after
software activation.
Operational status is
disabled and Circuit
Pack Failure alarm
raised for one CTL.
Please refer to
“Trouble
shooting
procedure B”.
Duplex control is
established properly
(green LED on one CTL
is lit, and LEDs on
second CTL are off, 1
hour after software
activation at the latest).
C NE in duplex control:
• Login to NE not
possible
• No traffic lost
• Green activity LEDs on
both CTLs are still
flashing 1 hour after
software activation.
Please refer to
“Trouble
shooting
procedure C”
(. 10-31).
Duplex control is
established properly
(green LED on one
CTL is lit, and LEDs
on second CTL are off,
1 hour after software
activation at the latest).
D NE in duplex control:
• No traffic lost
• Red fault LED on one
CTL is lit 1 hour after
software activation.
Please refer to
“Trouble
shooting
procedure D”.
Duplex control is
established properly
(green LED on one CTL
is lit, and LEDs on
second CTL are off,
1 hour after software
activation at the latest).
E NE in simplex or duplex
control:
• Login to NE not
possible
• Traffic lost
Please refer to
“Trouble
shooting
procedure E”.
NE software will be
restored to the previous
NE software version.
Current NE behavior Trouble
shooting
Resulting NE behavior
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 3 5Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Hold circuit packs only at the edges or on the insertion and removal
facilities. Always observe the ESD instructions.
Proceed as follows:
..................................................................................................................
1. Open the latches of the CTL.
Important! Do not immediately remove the CTL from its slot at
that time.
The green activity LED on the faceplate of the CTL starts flashing.
..................................................................................................................
2. Wait until the green activity LED has stopped flashing (about five
seconds).
..................................................................................................................
3. Remove the CTL from its slot.
..................................................................................................................
4. Reinsert the CTL in the CTL worker slot (slot 11) and wait until the
green activity LED is permanently lit.
Removing and reinserting the CTL is equivalent to a full reset of
the CTL.
..................................................................................................................
5. Try to login again.
Result: Login should now be possible again. Otherwise, please
refer to “Trouble shooting procedure E”.
..................................................................................................................
6. Check the status of the 1675.LambdaUnite®.MSS system, as
described in “To check for successful NE software upgrade”.
............................................................................................................................................................E N D O F S T E P S
Trouble shooting
procedure B
Proceed as follows:
..................................................................................................................
1. Login to the 1675.LambdaUnite®.MSS NE, using the
WaveStar®.CIT.
..................................................................................................................
2. Perform a controller reset to the standby CTL.
..................................................................................................................
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 3 6 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
3. Wait until the Operational Status of the standby CTL is Enabled
and the green activity LED stops flashing (is switched off).
The Operational Status can be retrieved via:
• the WaveStar®.CIT System View main menu: View --> View
Equipment Details (select the standby CTL) --> Status tab,
or
• the context menu (right-click popup menu) of the standby
CTL: View Circuit Pack Details --> Status tab.
..................................................................................................................
4. Check the status of the 1675.LambdaUnite®.MSS system, as
described in “To check for successful NE software upgrade”.
............................................................................................................................................................E N D O F S T E P S
Trouble shooting
procedure C
Electronic components can be destroyed by electrostatic discharge.
Hold circuit packs only at the edges or on the insertion and removal
facilities. Always observe the ESD instructions.
Proceed as follows:
..................................................................................................................
1. Open the latches of the CTL in the protection slot (slot 31).
Important! Do not immediately remove the CTL from its slot at
that time.
The green activity LED on the faceplate of the CTL starts flashing.
..................................................................................................................
2. Wait until the green activity LED has stopped flashing (about five
seconds).
..................................................................................................................
3. Remove the CTL from its slot.
..................................................................................................................
4. Repeat Step 1 to Step 3 for the CTL in the worker slot (slot 11).
..................................................................................................................
5. Reinsert the CTL in the CTL worker slot (slot 11) and wait until the
green activity LED is permanently lit.
Removing and reinserting the CTL is equivalent to a full reset of
the CTL.
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 3 7Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
..................................................................................................................
6. Try to login again.
Result: Login should now be possible again. Otherwise, please
refer to “Trouble shooting procedure E”.
..................................................................................................................
7. Reinsert the CTL in the CTL protection slot (slot 31) and wait until
the green activity LED is permanently lit.
Removing and reinserting the CTL is equivalent to a full reset of
the CTL.
..................................................................................................................
8. Wait until the Operational Status of the CTL in the CTL
protection slot is Enabled, and the green activity LED stops
flashing (is switched off).
The Operational Status can be retrieved via:
• the WaveStar®.CIT System View main menu: View --> View
Equipment Details (select the CTL in the protection slot) -->
Status tab, or
• the context menu (right-click popup menu) of the CTL in the
protection slot: View Circuit Pack Details --> Status tab.
..................................................................................................................
9. Check the status of the 1675.LambdaUnite®.MSS system, as
described in “To check for successful NE software upgrade”.
............................................................................................................................................................E N D O F S T E P S
Trouble shooting
procedure D
Electronic components can be destroyed by electrostatic discharge.
Hold circuit packs only at the edges or on the insertion and removal
facilities. Always observe the ESD instructions.
Proceed as follows:
..................................................................................................................
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 3 8 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
1.
..................................................................................................................
2. Perform a controller reset of the standby CTL.
..................................................................................................................
3. Wait until the Operational Status of the standby CTL is Enabled,
and the green activity LED stops flashing (is switched off).
The Operational Status can be retrieved via:
• the WaveStar®.CIT System View main menu: View --> View
Equipment Details (select the CTL in the protection slot) -->
Status tab, or
• the context menu (right-click popup menu) of the CTL in the
protection slot: View Circuit Pack Details --> Status tab.
..................................................................................................................
4. Perform a full reset of the standby CTL.
..................................................................................................................
IF THEN
login to the NE is possible, login to the
1675.LambdaUnite®.MSS NE, using
the WaveStar®.CIT, and then
continue with the next step.
login to the NE is not
possible
continue with Step 6.
IF THEN
the Operational Status of
the standby CTL is
Enabled, and the green
activity LED is switched off
after 1 hour at the latest,
continue with Step 8.
the Operational Status of
the standby CTL is still is
Disabled after 1 hour,
continue with the next step.
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 3 9Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
5. Wait until the Operational Status of the standby CTL is Enabled,
and the green activity LED stops flashing (is switched off).
The Operational Status can be retrieved via:
• the WaveStar®.CIT System View main menu: View --> View
Equipment Details (select the CTL in the protection slot) -->
Status tab, or
• the context menu (right-click popup menu) of the CTL in the
protection slot: View Circuit Pack Details --> Status tab.
..................................................................................................................
6. Remove the CTL, where the red LED is lit, from its slot.
..................................................................................................................
7. Reinsert the CTL.
..................................................................................................................
8. Wait until the Operational Status of the just reinserted CTL is
Enabled, and the green activity LED stops flashing (is switched
off).
The Operational Status can be retrieved via:
• the WaveStar®.CIT System View main menu: View --> View
Equipment Details (select the just reinserted CTL) --> Status tab,
or
• the context menu (right-click popup menu) of the just reinserted
CTL: View Circuit Pack Details --> Status tab.
..................................................................................................................
9. Check the status of the 1675.LambdaUnite®.MSS system, as
described in “To check for successful NE software upgrade”.
............................................................................................................................................................E N D O F S T E P S
IF THEN
the Operational Status of
the standby CTL is
Enabled, and the green
activity LED is switched off
after 1 hour at the latest,
continue with Step 9.
the Operational Status of
the standby CTL is still is
Disabled after 1 hour,
continue with the next step.
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 4 0 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
Trouble shooting
procedure E
Electronic components can be destroyed by electrostatic discharge.
Hold circuit packs only at the edges or on the insertion and removal
facilities. Always observe the ESD instructions.
Proceed as follows to restore the NE software to the previous NE
software version:
..................................................................................................................
1. Open the latches of the CTL in the worker slot (slot 11).
Important! Do not immediately remove the CTL from its slot at
that time. The green activity LED on the faceplate of the CTL starts
flashing.
..................................................................................................................
2. Wait until the green activity LED has stopped flashing (about five
seconds).
..................................................................................................................
3. Remove the CTL from its slot.
..................................................................................................................
4. If necessary, repeat Step 1 to Step 3 for the CTL in the protection
slot (slot 31).
..................................................................................................................
5. Insert the prepared CompactFlash® card (with the “old” NE
software and empty database) in the working CTL, and reinsert the
CTL in the CTL worker slot (slot 11).
Reference: “Prepare CompactFlash® card for fall back solution”.
..................................................................................................................
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 4 1Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
6. After the system boot has finished, login into the system with the
following default settings:
• NE-Name: UNITE-NE.
• User-Login: LUC01 (or LUC02)
• Password-Login: UNITE+01 (or UNITE+02)
Result: A password change is requested.
Important! The system is coming up in the maintenance mode. Do
not leave the maintenance mode at this state. Otherwise, all
traffic will be lost!
..................................................................................................................
7. Using the WaveStar®.CIT, start the database restore process of the
NE.
Make sure to select the correct directory of the database to be
restored (the location of the backup folder was recorded during the
preparation of the upgrade (cf. “To upgrade software to a new
release”, Step 3: database backup).
Reference: Please also refer to:
• “Manually backup database to the WaveStar®.CIT”
• “To restore a database to a network element”
Result: In case of successful starting, a progress indicator window
appears. After finishing of database restore to the NE, an automatic
reset of the NE takes place. As a consequence, the connection to the
NE will be lost for some minutes.
..................................................................................................................
8. Wait until the system reboot has finished.
..................................................................................................................
9. Login to the NE again using the login parameters (NE-Name, User-
Login, Password-Login), that were used before the upgrade was
started.
Important! The GE1 packs might hang up in recovery and a Cir-
cuit Pack Comm Failure (CPCOMF) alarm might be raised for
those packs.
To bring them back to operation up to two Controller Resets of the
GE1 packs might be necessary.
In Repeater mode traffic is not affected. In switched modes traffic is
affected until the GE1 pack is operational again as protocols like
Spanning Tree Protocol (STP) and Generic Attribute Registration
Protocol VLAN Registration Protocol (GVRP) are not working.
For details see the MTCG, chapter 3.
If applicable, and if no second upgrade trial is planned, delete all
files of the CompactFlash® card of the protection CTL and reinsert
the CTL in the CTL protection slot again. Wait until the operational
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 4 2 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
status of the CTL in the CTL protection slot is enabled (see System
View main menu, select View --> View Equipment Details, or
context menu of the protection CTL (right mouse button), select
View Circuit Pack Details) and the green activity LED stops flash-
ing (is switched off).
Important! If a second upgrade trial is planned, then leave out the
protecting CTL to avoid unnecessary CTL synchronization time.
..................................................................................................................
10. Check the status of the 1675.LambdaUnite®.MSS system, as
described in “To check for successful NE software upgrade”.
............................................................................................................................................................E N D O F S T E P S
E N D O F S T E P S
To retrieve NE software generic information
When to use Using the WaveStar®.CIT you can retrieve the current software version
ID. Software updates, or patches, are identified and included in the
current version, if appropriate.
NE active software The About NE window which displays the currently active NE software
version in the form explained above, is invoked by selecting Help -->
About This Network Element from the NE System View menu bar.
Instructions To invoke the CIT/NE Software display window proceed as follows.
..................................................................................................................
1. Select View --> Software Generic from the NE System View menu
bar.
Result: A file selection window is displayed.
Additional info With this invocation of the file selection screen,
only NE software type files stored on the CIT or on the NE are
selectable.
..................................................................................................................
2. Select a file or files or directory.
Reference: The displayed parameters are described in “Supporting
information for “Retrieving NE software generic information””.
............................................................................................................................................................E N D O F S T E P S
E N D O F S T E P S
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 4 3Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Supporting information for “Retrieving NE software generic information”
NE software display
window
WaveStar®.CIT allows the user to view the current status of the various
copies and releases of the NE software as they reside on the NE non-
volatile memory (NVM). The display includes the currently active
release and may include either the previous release or a newly
downloaded release which is not yet be applied.
Elements of the NE
software display window
Important! On the CompactFlash® card, there is room for two
databases, the current and the previous one. If a CompactFlash®
card never contained a second database, the content of the previous
partition is reported wrongly: the allocated size parameter for the
previous database is missing (“size=0”) and a serial number for that
non-existing database is reported.
The following information is displayed in the window for each file
selected by the user:
.
______________________________________________________________OBJECT DESCRIPTION/BEHAVIOR
Current generic the software release which is currently active for
the WaveStar®.CIT or network element.
NVM Selected file. If resident on the NE, the file
description indicates whether the file is
• Current,
• Previous, or
• Secondary
Otherwise it gives the directory tree and name of
the specific file.
NE Type Product type of alphanumeric characters
Release Software release, for example: 07.00.00.
Supplier Name of the supplier, currently Lucent.
Delivered Date and end time the software release was
downloaded onto the NE, if this is an NE file, or the
date and time the file was last modified if the file is
not on the NE.
Installed Date and start time the software release was
installed (activated) onto the NE. If this release has
not yet been applied, this field is empty.
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 4 4 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
Size Size of the software in bytes.
Possible values are integers from 0...999,999,999,
inclusive.
Source Source of the original download. Examples at this
time include CIT, EMS and FTTD along with a
file path and file name. If the source system is
either CIT, EMS or FTTD and if the file is on the
NE, the field additionally includes the psel, ssel,
tsel, and NSAP values for those systems:
• CIT,psel,ssel,tsel,nsap,filename
• EMS,psel,ssel,tsel,nsap,filename
• PRE-LOADED
The fields psel, ssel, tsel, nsap specify the GNE,
ranges are
• psel (path selector): 0-4 bytes represented as
0-8 hex characters,
• ssel (session selector): 0-4 bytes represented
as 0-8 hex characters,
• tsel (transport selector): 0-16 bytes
represented as 0-32 hex characters,
• nsap: 20 bytes represented as 40 hex
characters.
State State of this software release. It may take the
values:
• Corrupt
• Downloaded
• In Progress
• Failed
• Previous
• Running
• Initial.
• Preserved (for SW Downgrade during trial
phase)
Free NVM Space n/a (not applicable)
Unavailable NVM
Space
n/a (not applicable)
______________________________________________________________OBJECT DESCRIPTION/BEHAVIOR
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 4 5Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Database backup 0
Overview
Purpose This chapter describes the procedure which has to be carried out for a
NE database backup of the 1675.LambdaUnite®.MSS. Furthermore, the
procedure for retrieving information on the current NE database is
provided.
To limit the number of saved backups
Purpose Use this procedure to specify the maximum number of backup
directories to be saved.
Before you begin Before you begin this task:
• Obtain the work instructions for this task.
• Verify that a WaveStar®.CIT is connected and logged into the
1675.LambdaUnite®.MSS system.
Required equipment
The following equipment is required to perform this task.
• WaveStar® Customer Interface Terminal (WaveStar®.CIT)
Instructions Complete the following steps to manually backup the network element
database (current program and data) to the WaveStar®.CIT.
..................................................................................................................
1. At the WaveStar®.CIT, select Configuration --> Software -->
Remote Backup.
..................................................................................................................
2. In the Backup Database window select Setup.
Result: The Provision Backup Number screen appears.
..................................................................................................................
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 4 6 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
3. In the Provision Backup Number screen specify the maximum
number of backups to CIT per system.
Additional info: The parameter can be set to a number from 1 to
10, or it can be set to infinite by clicking the radio button Infinite.
..................................................................................................................
4. Click on OK.
............................................................................................................................................................E N D O F S T E P S
E N D O F S T E P S
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 4 7Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Manually backup database to the WaveStar® CIT
When to use Use this procedure to manually backup the network element database
(current program and data) to the WaveStar® Customer Interface
Terminal (WaveStar®.CIT):
• after initial software installations/upgrades/changes
• after major provisioning data changes
• periodically according to local policy
• before software upgrades/changes
• before major provisioning data changes
Safety precautions To assure both personal safety and the proper functioning of the
1675.LambdaUnite®.MSS system, it is imperative to review and
understand these warnings and precautions prior to performing this task.
Related information For related information, see:
• 1675.LambdaUnite®.MSS User Operations Guide, “Database
backup concepts”
• 1675.LambdaUnite®.MSS Alarm Messages and Trouble Clearing
Guide, “Manually Restore Database from the WaveStar®.CIT to an
NE”
Before you begin Before you begin this task:
• Obtain the work instructions for this task.
• Verify that a WaveStar®.CIT is connected and logged into the
1675.LambdaUnite®.MSS system.
• Ensure that no other user is remotely logged in (to the NE) and do
not perform any provisioning activities on the NE while the
database backup is running. Also ensure that no auto-/de-
provisioning activities (plug in/plug out of packs) are performed on
the NE while the database backup is running.
Required equipment
The following equipment is required to perform this task.
• WaveStar® Customer Interface Terminal (WaveStar®.CIT)
• For connecting the WaveStar®.CIT to the system via LAN
connections using a hub the following hubs are recommended:
– Hewlett Packard:
J3128A / Advanced Stack Hub-8E
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 4 8 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
– Allied Telesyn:
MR820TR
3024SL
MR815T
MR415T
Instructions Complete the following steps to manually backup the network element
database (current program and data) to the WaveStar®.CIT.
..................................................................................................................
1. At the WaveStar®.CIT, select Configuration --> Software -->
Remote Backup.
..................................................................................................................
2.
..................................................................................................................
3. In the FTAM tab specify the TID, PSEL, SSEL, TSEL and NSAP
for the FTAM information.
Reference: Continue with step Step 6.
..................................................................................................................
______________________________________________________________IF THEN
you want to backup the
database via FTAM,
in the Backup To/Via drop down list
box select FTAM.
Reference: Continue with step Step 3.
the connection to the NE is
through a TCP/IP
Gateway,
in the Backup To/Via drop down list
box select FTTD.
Reference: Continue with step Step 4.
you want to backup the
database directly to the
CIT,
in the Backup To/Via drop down list
box select CIT.
Result: A file selection screen appears
showing that the database will back up
to a specified folder under C:\Program
Files\Alcatel-Lucent\Wavestar
CIT\....or C:\Program Files\Lucent
Technologies\Wavestar CIT\.... The
directory of the file selection screen is
automatically pre-populated.
Reference: Continue with step Step 7.
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 4 9Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
4. In the FTTD tab specify the TID, PSEL, SSEL, TSEL and NSAP
for the FTTD information.
..................................................................................................................
5. In the FTP tab specify the Server, IP or Name, Port (optional), User
Name (optional) and User Password (optional) for FTP information
..................................................................................................................
6. Specify the Destination directory path.
Additional info: If you backup with FTP or FTTD feature you can
write backups into any directory you want.
When making a backup the directory structure must be compliant
with the directory structure which is used when making a backup
via CIT.
..................................................................................................................
7. Record the path/destination of the backup folder/files and click on
Backup.
Result: The NE Data Progress Indicator Screen appears.
..................................................................................................................
8. Important! TCP/IP connections are aborted automatically after 60
minutes of inactivity (an “inactive TCP connection” is a TCP
connection over which no TL1 messages are transmitted in either
direction).
To avoid this behavior during the current action, perform an action
like clicking on the Update Alarms button in the system view
which causes TL1 messages (RTRV-ALM-ALL, RTRV-ALM-
ENV) to be sent to the NE.
..................................................................................................................
9. If the backup went wrong for any reason the following screen is
displayed stating:
The backup went wrong.
Do you want to delete the backup directory:
<path of the backup directory>
You have decide either to delete or not to delete the backup direc-
tory, and either to click Yes or No.
..................................................................................................................
10. Important! If the current action has been interrupted. Wait for
about 10 minutes. After 10 Minutes the NE has recovered from the
last action and a new download/restore/backup can be executed.
When the NE Data Backup in Progress screen disappears and the
backup is complete, select View --> NE Data...
Result: The File Selection Screen appears.
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 5 0 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
..................................................................................................................
11. Select CIT in the Look in: field and double click on C:, Program
Files, Alcatel-Lucent or Lucent Technologies, WaveStar®.CIT, and
Backups. Then click on the backup folder number and on OK.
Result: The Database Info Screen appears.
..................................................................................................................
12. Verify the Last Backup Time and Last Backup Destination
parameters and click on Close.
............................................................................................................................................................E N D O F S T E P S
..................................................................................................................
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 5 1Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
To retrieve NE database information
When to use Via the WaveStar®.CIT you can retrieve the NE Backup status as
reported by the NE as well as showing the release number of NE Data
backup files resident on the CIT.
Instructions To invoke the Database Info window proceed as follows.
..................................................................................................................
1. Select View --> NE Data from the System View menu bar.
Result: A file selection window is displayed.
..................................................................................................................
2. Select a file or files or directory.
Reference: The displayed parameters are described in “Supporting
information for Retrieving NE database information”.
............................................................................................................................................................E N D O F S T E P S
E N D O F S T E P S
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 5 2 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
Supporting information for Retrieving NE database information
Elements of the Database
Info window
The Database Info window consists of two tabs, Remote and Local.
These two tabs show the following information for the file(s) selected by
the user:
.
______________________________________________________________OBJECT DESCRIPTION/BEHAVIOR
Current generic the software release which is currently active for
the WaveStar®.CIT or network element.
NVM Selected file. If resident on the NE, the file
description indicates whether the file is
• Current,
• Previous, or
• Secondary
Otherwise it gives the directory tree and name of
the specific file.
TID TID of the NE from which the configuration data
was stored on this NVM.
Serial Number Serial number
Software Release Software release corresponding to the data.
Size Size of the file in bytes.
Possible values:
• integers ranging from 0 to 999,999,999
inclusive.
State State of this data. It may take the values:
• Backup
• Corrupt
• Downloaded
• Failed
• Initial
• In Progress
• Previous
• Running.
• Preserved (for SW Downgrade during trial
phase)
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 5 3Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Last/Previous
Backup Time
Date and time when the data was backed up from
the NE. If there has been no backup, this field is
blank.
Last/Previous
Backup Location
Destination of the most recent backup. Examples
at this time include FTTD, EMS, and CIT and a
file name/path. If there has been no backup, this
field is blank.
Last/Previous
Backup Time
Date and time when the data was restored to the
NE. If there has been no restoral, this field is blank.
This field only applies to files on the NE.
Last/Previous
Backup Source
Source of the most recent restore. Examples at this
time include EMS, WaveStar®.CIT and FTTD
plus a file name/path. If there has been no restoral,
this field is blank.
______________________________________________________________OBJECT DESCRIPTION/BEHAVIOR
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 5 4 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
To restore a database to a network element
Purpose Use this procedure to restore a previously saved database to a network
element.
Important! A restore of a database will not be possible if the NE is
in the trial phase (PRESERVED state).
Safety precautions To assure both personal safety and the proper functioning of the
1675.LambdaUnite®.MSS system, it is imperative to review and
understand these warnings and precautions prior to performing this task.
Important! If provisioning changes were made after the last
backup files were created, use the appropriate WaveStar®.CIT com-
mands to manually apply the recent provisioning changes to the
just-restored database.
Do not remove or reset the standby (inactive) CTL while a software
download or database restoration is in progress. Otherwise, the soft-
ware download or database restoration will be aborted.
Before you begin Before you begin this task:
• Obtain the work instructions for this task and note the database to
be restored and the location of the most recent backup files.
• Verify that a WaveStar®.CIT is connected and logged in to the
1675.LambdaUnite®.MSS network element (NE) where the
database is to be restored.
• You have to log in as one of the two predefined super user logins.
Required privilege code
You must have at least a privilege code of S4.
Required equipment
The following equipment is required to perform this task.
• WaveStar® Customer Interface Terminal (WaveStar®.CIT)
• For connecting the WaveStar®.CIT to the system via LAN
connections using a hub the following hubs are recommended:
– Hewlett Packard:
J3128A / Advanced Stack Hub-8E
– Allied Telesyn:
MR820TR
3024SL
MR815T
MR415T
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 5 5Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
Instructions Complete the following steps to manually restore a database to a
network element:
..................................................................................................................
1. From the System View main menu, enter the maintenance
condition via Fault --> Enter/Exit Maintenance Condition... -->
Enter Maintenance Condition...
..................................................................................................................
2. Confirm the resulting system message by clicking OK.
..................................................................................................................
3. Select Configuration --> Software --> Remote Restore... from
the System View main menu.
Result: The Restore Database window will be opened.
..................................................................................................................
4. Proceed as follows:
..................................................................................................................
5. Select “CIT” in the Look in field and double click successively on
C:, Program Files, Alcatel-Lucent or Lucent Technologies,
Wavestar CIT, and backups.
Proceed Step 8.
..................................................................................................................
______________________________________________________________IF THEN
you want to restore the
database directly from the
PC where the
WaveStar®.CIT is
installed,
select CIT in the Restore From/Via
drop down list box.
Result: A file selection screen appears
showing that the database will back up
to a specified folder under C:\Program
Files\Alcatel-Lucent\Wavestar CIT\....
or C:\Program Files\Lucent
Technologies\Wavestar CIT\.... The
directory of the file selection screen is
automatically pre-populated.
Reference: Proceed with Step 5.
the connection to the NE is
through a TCP/IP gateway,
select FTTD in the Restore
From/Via drop down list box.
Reference: Proceed with Step 6.
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 5 6 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
6. Select the FTTD tab and specify the TID, presentation selector
(Psel), session selector (Ssel), transport selector (Tsel) and the
NSAP Address for the FTTD information.
..................................................................................................................
7. Select the FTP tab and specify the Server (IP address or server
name), port information (optional), User name (optional) and
password (optional) for the FTP information.
Proceed with Step 8.
..................................................................................................................
8. Important! Be careful to select the correct backup files to restore
to the NE. Specify the path to the folder where the backup files
reside.
Important! The NE does not restore a backup file properly if the
release number of the backup file is not the same as the release
number of the running SW.
Restoring a backup file with a different release number
Restoring a backup file with a different release number is quite
dangerous for the consistency of the database and the configuration
of the system and should therefore only be performed in emergency
cases by trained personal.
To restore a backup file with a different release number as the run-
ning software you have to perform the following:
• open the file named db (in the WaveStar®.CIT) in the directory
where the backuped information (list of files) are stored, using
a text editor
• in this file change the release number of the backup file to the
release number of the running SW.
..................................................................................................................
9. Verify your settings and correct if necessary. Then click Restore.
..................................................................................................................
New Installation and Upgrade Procedures
...............................................................................................................................................................................................................................................................
4 - 5 7Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
10. Confirm the resulting system message by clicking YES.
Important! TCP/IP connections are aborted automatically after 60
minutes of inactivity (an “inactive TCP connection” is a TCP con-
nection over which no TL1 messages are transmitted in either direc-
tion).
To avoid this behavior during the current action, perform an action
like clicking on the Update Alarms button in the system view
which causes TL1 messages (RTRV-ALM-ALL, RTRV-ALM-
ENV) to be sent to the NE.
Result: The NE Data Restore in Progress window appears. When
the database restore is complete, the system will perform a reset. As
a consequence, the management association between the Wave-
Star®.CIT and the NE will be lost. After the system reset has fin-
ished, you can re-establish the management association by again
connecting the WaveStar®.CIT to the NE.
..................................................................................................................
11. If the current action has been interrupted. Wait for about 10
minutes. After 10 minutes the NE has recovered from the last action
and a new download/restore/backup can be executed.
..................................................................................................................
12. Connect to the NE again.
Result: The NE comes up in maintenance mode if during startup a
data base with a not matching serial number is detected. However,
if the original data base (with matching serial number) is restored,
the NE does not come up in maintenance mode.
..................................................................................................................
13.
..................................................................................................................
14. From the System View main menu, select Fault --> Enter/Exit
Maintenance Condition... --> Exit Maintenance Condition...
..................................................................................................................
15. Confirm the resulting system message by clicking OK.
Additional info: The 1675.LambdaUnite®.MSS NE will now per-
form a system reset. As a consequence, the management association
between the WaveStar®.CIT and the NE will be lost. After the sys-
______________________________________________________________IF THEN
the NE comes up in
maintenance mode,
continue with Step 14.
the NE does not come up in
maintenance mode,
the procedure is ended.
...............................................................................................................................................................................................................................................................
New Installation and Upgrade Procedures
4 - 5 8 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
tem reset has finished, you can re-establish the management associ-
ation by again connecting the WaveStar®.CIT to the NE.
............................................................................................................................................................E N D O F S T E P S
E N D O F S T E P S
5 - 1Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
...............................................................................................................................................................................................................................................................
5 Miscellaneous
............................................................................................................................................................................................................................................................
Contents 0
Supported NE Releases with WaveStar®.CIT 5 - 2
1675.LambdaUnite®.MSS 5 - 2
Other NE Types 5 - 2
Technical Support (TSC/TEC) 5 - 3
Technical Support Groups 5 - 3
Contacting Your Local/Regional TSC 5 - 3
Product Support 5 - 3
Services 5 - 3
Technical Support Platform 5 - 3
Reference 5 - 4
...............................................................................................................................................................................................................................................................
Miscellaneous
5 - 2 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Supported NE Releases with WaveStar®.CIT 0
1675.LambdaUnite®
.MSS The traditional part of WaveStar®.CIT Software Release.18.09.05
Build.50xy supports 1675.LambdaUnite®.MSS
• Release.11.1.11
• Release 11.01.26
• Release 11.01.27
• Release 11.01.28
.
Other NE Types Please refer to file ’release.txt’ in the folder ’cit’ of the CD for
information on the support of other network elements and their releases
by WaveStar®.CIT Software Release.18.09.05 Build.50xy.
Miscellaneous
...............................................................................................................................................................................................................................................................
5 - 3Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS), Release.11.01.28 Software Release DescriptionIssue 1.0, Nov. 2012
............................................................................................................................................................................................................................................................
Technical Support (TSC/TEC) 0
Technical Support Groups Technical support is available through:
• Local/Regional TSC
• OND Support TEC (Technical Excellence Center Nuremberg)
Contacting Your
Local/Regional TSC
Local/Regional Technical Support Centers (TSC) personnel troubleshoot
field problems 24 hours a day over the phone and on site (if necessary)
based on Alcatel-Lucent Service Contracts:
For technical assistance, call your Local/Regional Customer Support
Team. If the request cannot be solved by Local/Regional TSC, it will be
escalated to the TEC team who maintain direct contact with Alcatel-
lucent manufacturing, Research & Development, and other organizations
to assure fast resolution of all assistance requests.
Product Support The Alcatel-Lucent OND TEC (Nuremberg, Germany) organization is
committed to providing customers with quality product support
sercvices. Each segment of the Technical Support organization regards
the customer as its highest priority and understands your obligations to
maintain quality sercvices for your customers.
Services Alcatel Lucent 1675 LambdaUnite MSS is complemented by a full range
of services available to support planning, maintaining, and operating
your system. Application testing, network integration, and
upgrade/conversion support is also available.
Technical Support Platform A global online trouble tracking system is used by all support teams to
track customer assistance requests. The system communicates details
about product bulletins, troubleshooting procedures, and other critical
for north and south
America (NAR and
CALA)
Customer Technical Assistance Management (CTAM):
• +1 866 Lucent8 (prompt#1)
• +1 630 224 4672 (from outside the United States)
for Europe, Africa, Asia
and the pacific region
(EMEA and APAC)
International Customer Management Centre (ICMC):
• +353 1 692 4579 (toll number)
• 00 800 00Lucent (toll free number in most EMEA
countries)
...............................................................................................................................................................................................................................................................
Miscellaneous
5 - 4 Alcatel-Lucent - Proprietary
See Notice on first page
1675 LambdaUnite® MultiService Switch (MSS),Release.11.01.28 Software Release Description
Issue 1.0, Nov. 2012
information to customers. All details of a request are entered into this
database until closure. For online access to your trouble tickets via the
web please contact your local support team.
Reference For additional information about technical support, please contact your
Alcatel-Lucent Local/Regional Technical Support Center or visit
http://www.alcatel-lucent.com/wps/portal/support.