Post on 14-May-2023
J. Aerosol Sci. Vol. 30, No. 2, pp. 247—263, 1999( 1998 Elsevier Science Ltd. All rights reserved
Printed in Great Britain0021-8502/98 $19.00#0.00PII: S0021-8502(98)00039-1
NORDIC INTERCOMPARISON FOR MEASUREMENT OFMAJOR ATMOSPHERIC NITROGEN SPECIES
Tuomo A. Pakkanen,*s Risto E. Hillamo,* Minna Aurela,* Helle Vibeke Andersen,tLone Grundahl,t Martin Ferm,° Karin Persson,° Vuokko Karlsson,± Anni Reissell,±
Oddvar R+yset,E Inga Fl+isand,E Pedro Oyola**,tt and Tadeusz Ganko**
* Finnish Meteorological Institute, Aerosol Research Group, Sahaajankatu 20E, FIN-00810 Helsinki, Finlandt National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde, Denmark
° Swedish Environmental Research Institute, P.O. Box 47086, S-402 58 Gothenburg, Sweden± Finnish Meteorological Institute, Laboratory Group, Sahaajankatu 20E, FIN-00810 Helsinki, Finland
E Norwegian Institute for Air Research, Box 100, N-2007 Kjeller, Norway** Institute of Applied Environmental Research at the University of Stockholm Frescati Hagvag 16 B,
S-106 91 Stockholm, Sweden
(First received 12 November 1997; and in final form 9 March 1998)
Abstract—A comparative study of measurements of atmospheric gaseous nitric acid and ammoniaand particulate nitrate and ammonium concentrations was conducted using various types of filterpacks and denuder systems. Some of the filter packs used are recommended by the EuropeanMonitoring and Evaluation Programme (EMEP) and are widely used in the Nordic Countries andelsewhere in Europe. In addition, nitrogen dioxide was measured using iodide-impregnated sinteredglass filters and the differential optical absorption spectrometer method. Particulate nitrate andammonium concentrations were measured with two different size segregating samplers: a Bernerlow-pressure impactor and a virtual impactor. The weather conditions were most of the time cooland humid. The agreement between different measurements was good for most species, but poor forgaseous ammonia. The virtual impactor collected on average 17% more nitrate than the denudersystems, 24% more than filter packs and 37% more than the Berner low-pressure impactor. Thenitrate discrepancy is believed to be due to inefficient coarse particle transport into the denudersystems, fine particle nitrate evaporation in the filter packs and Berner low-pressure impactor and,to a lesser extent, possible collection of nitric acid by the virtual impactor. A substantial fraction ofPM
2.5may be lost if the nitrate evaporation cannot be accounted for. The denuder systems did not
collect particles larger than about 5.6 km equivalent aerodynamic diameter efficiently. Interferenceswere observed on the nitric acid measurements determined by a NaOH coated denuder. NaClcoated denuders seemed to operate well in this study since interferences were not observed. ( 1998Elsevier Science Ltd. All rights reserved
1 . INTRODUCTION
Previous comparisons (Pio, 1992; Benner et al., 1991; Harrison and Kitto, 1990; Dasch et al.,1989; Ferm et al., 1988; Eatough et al., 1988; Hering et al., 1988) have shown that thedenuder systems (DS) are suitable for determination of ammonia (Ferm, 1979), ammonium,nitric acid and nitrate although some interferences may occur. Depending for instance onthe sampling site, weather conditions and the acidity of sampled aerosol the filter packmethods (FP) sometimes can suffer from serious problems leading to erroneous results(Andersen and Hovmand, 1994; Andersen and Hilbert, 1993). Earlier studies suggest furtherthat the size-segregation samplers, virtual impactor (VI) (Loo and Cork, 1988) and Bernerlow-pressure impactor (BLPI) (Berner and Lurzer, 1980), can be used as accurate methodsfor determination of nitrate. Wall et al. (1988) reported that volatile nitrate losses in a BLPIwere less than 10% and that interference from nitric acid was not detected; John et al. (1988)observed that the inner oxidized aluminum surfaces of a VI efficiently denuded nitric acid.Thus the VI was an interference and artifact free instrument when used for the determina-tion of nitrate.
In this work, NO2
was monitored by the differential optical absorption spectrometer(DOAS) and collected by reducing NO
2to NO~
2on impregnated filters. Two different
sAuthor to whom correspondence should be addressed.ttPresent address: CONAMA-RM, McIver 283, Piso 7, Santiago, Chile.
247
formulas for the reduction was used. In the older version KI and NaAsO2
were used toreduce NO
2and ethylene glycol to keep the filter humid. NaAsO
2also kept the pH high. To
avoid the handling of arsenite a new formula was designed. In this NaI was used to reduceNO
2to NO~
2and Na
2CO
3to keep the pH high (Ferm and Sjodin, 1992). NaI is more
deliquescent than KI and keeps the filter humid. To get a high efficiency at a reasonableflow, and a leak proof filter holder that was simple to handle, a glass bulb with a sinteredglass filter was constructed.
The concentrations measured in this work by each individual instrument were presentedin detail in the report to Nordic Council of Ministers: Nordic HNO
3/NO~
3and NH
3/NH`
4gas/particle intercomparison in Helsinki, 11—22 May, 1992 (Pakkanen et al., 1994). Insteadof the individual results the present paper compares the different types of measurementinstruments used: the DS, FP, VI, BLPI, impregnated glass sinters (IGS) and the DOASmethod. In addition, the differences between nitrate measurements and interferences on thenitric acid measurements are discussed. The mass of particulates was not measured but onbasis of later measurements can be estimated to have been on average about 10 kgm~3 forPM
2.5and 15 kgm~3 for PM
15.
2 . EXPERIMENTAL
2.1. Field site of the intercomparison study
The comparative field study was conducted in Helsinki, 11—22 May 1992. The samplingsite was on the roof of the Finnish Meteorological Institute, Air Quality Departmentbuilding, seven km to the east from the centre of Helsinki. The roof is about 20m aboveground level. Car traffic is obviously the most important local pollution source with onemajor road 350 m to the northwest and another road with moderate traffic adjacent to theFMI building. The sea coast is about 2 km south of the sampling site.
2.2. Participants and sampling methods
Five institutes from four Nordic countries participated in the intercomparison: theNational Environmental Research Institute (DMU) from Denmark, two groups from theFinnish Meteorological Institute (FMI) from Finland, the Norwegian Institute for AirResearch (NILU) from Norway, and the Swedish Environmental Research Institute (IVL)and the Institute of Applied Environmental Research at the University of Stockholm(ITML), from Sweden. A summary of the sampling methods and the correspondingsampling flow rates are listed in Table 1. Nitrogen dioxide concentrations were comparedfor two KI-impregnated and two NaI-impregnated glass sinters (Ferm and Sjodin, 1992)and for the DOAS instrument. Three DSs and two FPs were used to measure ammonia.Ammonium was determined by three DSs, two FPs, a VI and a BLPI. Nitric acidconcentrations were measured using six DSs and two FPs. Nitrate measurements werecarried out with six DSs, two FPs, the VI and the BLPI. In addition, one FP was used tomeasure the sum of ammonia and ammonium (total ammonium) and another FP was usedto measure the sum of nitric acid and nitrate (total nitrate). These FPs measuring totalammonium and total nitrate were similar to those recommended by EMEP. The VI used inthis work was made of stainless steel. The BLPI and the VI were equipped with stainlesssteel aerosol inlets (University of Minnesota type inlets; Liu and Pui, 1981). The VI samplesparticles in two size fractions: particle aerodynamic diameter EAD(2.5 km and2.5(EAD (15 km. The BLPI collects particles in ten size fractions in the size range of0.03(EAD(15 km. Coarse particle substrates of the BLPI were greased to minimizeparticle bounce-off (Hillamo and Kauppinen, 1991).
2.3. Sampling schedule
Sampling was started either 9 a.m. or 9 p.m. The virtual impactor, most of the denudersystems and one filter pack collected for five 12 h and eight 24 h periods whilst the Berner
248 T. A. Pakkanen et al.
Table 1. Sampling methods and the volume flow rates as measured by laminar flow elements during thecomparison. Flow rates are as l min~1 at 101.3 kPa and 24°C
Code Inlet (cut-off ) Sampling line Flow rate
DMU.FP — TF—NaF/IF—KOH/IF—oxalic acid/IF 44.36DMU.DS1 — NaOH/D—NaOH/IF 1—2*DMU.DS2 — NaCl/D—NaOH/IF 1—2*DMU.DS3 — Na
2CO
3/D—Na
2CO
3/IF 1—2*
DMU.DS4 — Oxalic acid/D—oxalic acid/IF 1—2*FMI.FP1s — CF—NaOH/IF 18.5t
FMI.FP2s — Oxalic acid/IF 20.8t
FMI.ADS Cyclone (3.5 km) Na2CO
3/D—Na
2CO
3/D—citric acid/D—TF—NF 29.14
FMI.BLPI UM inlet (15 km) 11-stage Berner low-pressure impactor 25.0t
FMI.VI UM inlet (15 km) Virtual impactor; fine: TF—NF, coarse: PF 16.7t
FMI.NaI — NaI/IGS 0.51IVL.DS1 — NaCl/D—NaCl/IF 1.81IVL.DS2 — Oxalic acid/D—oxalic acid/IF 2.29IVL.KI — KI/IGS 0.43IVL.NaI — NaI/IGS 0.42NILU.FP — TF-KOH/IF—oxalic acid/IF 16.6*NILU.KI — KI/IGS 0.57ITML.ADS — NaCl/D—Na
2CO
3/D—Na
2CO
3/D—Na
2CO
3/IF 2.78*
ITML.DOAS — Differential optical absorption spectrometer
Symbols :IGS impregnated glass sinterD denuderDS denuder systemADS annular denuder systemFP filter packUM University of Minnesota inletNaI sodiumiodideTF Teflon filterCF cellulose filterIF impregnated filterNF nylon filterPF polycarbonate filterKI potassiumiodide* Flow rates indicated show an average or range of two separate sampling lines.s Similar to those recommended by EMEP.t Flow rate not checked with laminar flow elements.
low-pressure impactor collected for two 24h and four 48 h periods. The denuder systems ofthe DMU and ITML were used to collect more 12h samples than the other instruments,but some of these 12 h periods were combined to 24h periods to match those of the otherinstruments.
2.4. Chemical analysis
After collecting the samples were dissolved and stored mostly in dark and cool. In orderto check the influence of variable sample transportation to and storage (because of possibleammonium losses storing needs to be made in dark as shown by Ferm, 1993) at eachparticipating laboratory, reference samples with known concentrations were prepared atthe FMI by dilution of appropriate commercial standard solutions. These reference sampleswere then analysed at each laboratory and the results exhibited only minor differences(Pakkanen et al., 1994). The components were usually analyzed by ion chromatography(IC), but other techniques such as the spectrophotometric indophenol blue method forammonium were also employed.
2.5. ¼eather conditions
The temperature and the relative humidity, recorded at the sampling site, together withother weather data registered in a synoptic station near the FMI main building, 7 km from
Nordic intercomparison of major atmospheric nitrogen species 249
Table 2. Summary of weather condition
Temp (°C) Temp (°C) RH (%) RH (%) Rain (mm) Wind (m s~1) CloudinessMay range average range average average average average*
11n 2—7 5 75—95 89 2 5.312 4—10 7 50—94 75 8.5 3.4 5.813 4—10 7 60—95 75 0.4 4.4 3.614 6—16 11 30—80 50 2.3 1.615 7—12 9 60—85 75 3.4 1.016 8—13 10 60—90 75 0.6 5.2 4.417 6—15 11 40—75 55 4.2 1.618 10—20 14 35—60 47 4.0 4.419d 10—16 13 40—80 60 1.6 2.719n 8—17 11 30—90 70 2.6 1.720d 17—20 19 20—45 27 4.0 1.020n 8—17 11 45—75 60 0.1 1.4 3.721 8—18 12 50—85 75 2.1 4.6
d: day; n: night.*Scale for cloudiness: 0"clear sky% 8"cloudy sky.
the sampling site, are summarized in Table 2. Generally, the weather was rather windy andsunny with the temperatures usually between 5 and 15°C and the relative humidities usuallyhigher than 50%.
3. RESULTS AND DISCUSSION
Results deviating by more than twice the standard deviation were excluded as outliers.Some instruments occasionally suffered from identifiable problems and in such cases evenresults deviating by about the standard deviation were discarded. The outliers were nottaken into account while calculating the average values. The number of outliers is shown inTable 3 as a percentage from total number of individual measurements.
3.1. Size distributions of nitrate and ammonium
Mass size distributions are useful in the estimation of possible reasons to the differencesobserved on the particle measurements, since the chemical nature of fine and coarseparticles is usually different for most constituents. In this work Berner low-pressureimpactors were used to determine size distributions of the particulate nitrogen compounds,ammonium and nitrate. The data inversion code MICRON (Wolfenbarger and Seinfeld,1990, 1991) was used in the evaluation of the size distributions, presented in Fig. 1. Overallthe size distributions observed in this work showed characteristics similar to those observedin California (John et al., 1990).
Nitrate exhibited one or two fine particle modes and two overlapping coarse particlemodes (Pakkanen et al., 1996). Coarse nitrate is usually present in the form of non-volatilenitrate compounds (Yoshizumi and Hoshi, 1985). The VI and BLPI data agreed well forcoarse particle nitrate concentrations but it should be noted that about half of the fineparticle nitrate evaporated from the BLPI (see Fig. 5) which is further discussed in theSection 3.7.
Figure 1 indicates that ammonium and sulphate usually exhibited two fine particle modesand two coarse particle modes. About 95% of ammonium was contained in the fine particlesize range. The ammonium and sulphate size distributions were very similar for particlesbelow 1 km EAD. The observed ammonium mole concentration was about twice that ofsulphate. Given the low nitrate concentrations observed, it would appear that sulphate andammonium were mostly present as (NH
4)2SO
4and that the fine aerosol therefore was only
slightly acidic or neutral (Seinfeld, 1986). As discussed above, approximately half of the fineparticle nitrate evaporated from the BLPI (see Fig. 5) which implies that also some fineparticle ammonium likely evaporated (NH
4NO
3and NH
4Cl are the major volatile
250 T. A. Pakkanen et al.
Table 3. DOAS/average IGS concentration ratios for nitrogen dioxide and ave.FP/ave.DS, VI/ave.DS andBLPI/ave.DS concentration ratios for particulate ammonium and nitrate. In addition the ave.FP/ave.DS concen-tration ratios are shown for gaseous ammonia and nitric acid and for the sum of ammonia#ammonium ("totalammonium) and for the sum of nitric acid#nitrate ("total nitrate). The number of valid comparisons is indicated
in parantheses after each ratio value
Measurement Total TotalConc. ratio time (h) NO
2NH
3NH`
4NH`
4HNO
3NO~
3NO~
3
DOAS/average IGS 12 1.61 (4)24 1.64 (7)
Average FP/average DS 12 1.06 (5) 0.90 (4) 1.23 (5)* 0.94 (5) 0.95 (5) 0.93 (5)24 1.11 (8) 0.93 (7) 0.94 (8) 0.84 (7) 0.99 (8) 0.97 (8)
VI/average DS 12 1.04 (4) 1.33 (5)24 1.08 (7) 1.20 (6)
BLPI/average DS 24 1.02 (2) 0.85 (2)48 0.99 (4) 0.86 (4)
Total number of outliers (%) 5% 24% 13% 14% 1% 10% 4%
*Only one FP measured 12 h periods; this FP showed the highest FP concentrations for total ammonium for the24h periods.
ammonium salts). However, this ammonium volatilization had only a small influence on theammonium concentrations measured by the BLPI, since ammonium was mostly present asnon-volatile ammonium sulphate.
3.2. Nitrogen dioxide
Figure 2 and Table 3 show the results from the comparison between the averageconcentrations obtained by the four impregnated glass sinter (IGS) measurements and theDOAS method. The IGS measurements were consistent (Pakkanen et al., 1994) thoughindicating lower NO
2concentrations than the DOAS method. A possible explanation for
the disagreement observed may be an inhomogeneous nitrogen dioxide concentration alongthe 440m long DOAS measurement beam: the DOAS light source was situated only 40maway from a road with high traffic density, whereas the DOAS receiver together with theIGS samplers were about 350m from that road.
3.3. Ammonia
Figure 3A and Table 3 indicate that the ammonia concentrations determined by the twoFPs and the three DSs showed reasonable agreement: the average FP to average DS ratioswere 1.06 and 1.11 for the 12 and 24 h measurements, respectively. It should be noted,however, that several outliers were excluded while calculating the average FP and averageDS values. The likely reasons for the measurement errors are discussed in detail byPakkanen et al. (1994). In fact, for several sampling periods the individual measurementresults showed such a great variation that the estimation of the actual concentration in theatmosphere studied was difficult. The probable reason for the slightly high ratios could havebeen the evaporation of particulate ammonium nitrate and/or ammonium chloride fromthe FP Teflon pre-filter and subsequent collection of ammonia on the FP impregnated filterwhich is a common artifact in FPs (see Table 1 for the configuration of the two FPs:DMU.FP and NILU.FP). A special feature in our measurements was that the FP/DS ratiosfor ammonia were higher (with the exception of the first sample) when the nitrate concentra-tions were high. This same feature has been observed also elsewere (Ferm, 1986a).
3.4. Ammonium
Figures 3B, C and D show comparisons of measured average FP, VI and BLPIammonium values to the average DS ammonium values, respectively. The corresponding
Nordic intercomparison of major atmospheric nitrogen species 251
Fig. 1. Size distributions of ammonium, nitrate and sulphate during the intercomparison. Thenitrate mass below 2 km EAD is underestimated because of evaporation. The six figures refer toBLPI samples 1—6, respectively. The data inversion code MICRON (Wolfenbarger and Seinfeld,
1990, 1991) was used in the evaluation of the size distributions.
252 T. A. Pakkanen et al.
Fig. 2. Comparison of DOAS and average impregnated glass sinter (IGS) concentration values fornitrogen dioxide.
average ammonium ratios between the methods for 12 and 24h (and also 48 h for BLPI)measurements are indicated in Table 3. The average denuder values agreed well with theBLPI, VI and average FP values. The slightly larger FP-DS difference is probably due toevaporation of ammonium nitrate and/or ammonium chloride from the teflon pre-filter ofthe filter packs.
3.5. ¹otal ammonium
One of the three filter packs measuring total ammonium was similar to that recommen-ded by EMEP. Figure 3E and Table 3 indicate that the FPs and the DSs agreed well. Theaverage filter pack to average denuder system ratio for the 24 h measurements variedbetween 0.88 and 1.24 with an average of 0.99. The highest ratios, 1.10 and 1.24, occurredduring the four 12 h sampling periods of 19 and 20 May combined here as 24 hmeasurements.
3.6. Nitric acid
The ratios of average FP values to average DS values were usually below one for the 24 hmeasurements, except the outlier ratio of 1.57 (Fig. 4A and Table 3). The measurementsindicated that for this outlier there was a significant difference between the two techniques.The reason for the difference observed is unclear although evaporation of particulate nitratefrom the FP prefilters may have occured. However, it is strange that this evaporationseemed to be much different for the other samples. Table 3 shows that the mean of averagefilter pack to average denuder system ratios for the 24 h measurements was 0.84 (the value of1.57 excluded), indicating that the denuder systems collected slightly more nitric acid. Thisis primarily because of the lower values obtained by the KOH-impregnated filter of theNILU filter pack (NILU.FP). The 12 h measurements exhibited slightly better FP-DSagreement but four of the five comparisons are based on only one FP value, that of theDMU.FP. In general, the three different denuder methods of DMU agreed well and thisdata is used for detailed discussion of interferences on the measurement of nitric acid (seeSection 3.9).
Nordic intercomparison of major atmospheric nitrogen species 253
Fig. 3. Comparison of average denuder system (DS) values with average filter pack (FP), virtualimpactor (VI) and Berner impactor (BLPI) values. (A) FP-DS comparison for ammonia; (B) FP-DScomparison for ammonium; (C) VI-DS comparison for ammonium; (D) BLPI-DS comparisonfor ammonium; (E) FP-DS comparison for total ammonium (sum of ammonia and ammonium).
Note: The points in parentheses are not included in the calculations of Table 3.
3.7. Nitrate
The results for particulate nitrate are presented in Figs 4B—D and in Table 3. On averagethe agreement was relatively good for the various methods, with the VI showing the highestand the BLPI the lowest concentrations. The mean values of the FP/DS ratios for nitratewere 0.95 and 0.99 for the 12 and 24h measurements, respectively. The VI/DS ratios werebetween 1.04 and 1.66 (one high ratio of 2.25 excluded) and the BLPI/DS ratios showedvalues ranging from 0.74 to 0.94. On average, the VI gave nitrate concentrations that were17, 24 and 37% higher than those of the denuders (two high percentages excluded;
254 T. A. Pakkanen et al.
Fig. 4. Comparison of average denuder system (DS) values with average filter pack (FP), virtualimpactor (VI) and Berner impactor (BLPI) values. (A) FP-DS comparison for nitric acid; (B) FP-DScomparison for nitrate; (C) VI-DS comparison for nitrate; (D) BLPI-DS comparison for nitrate(E) FP-DS comparison for total nitrate (sum of nitrate and nitric acid). Note: The points in
parentheses are not included in the calculations of Table 3.
FMI.ADS excluded because the cyclone removes particles larger than 3.5 km of EAD),those of the filter packs (two high percentages excluded) and those of the BLPI (one highpercentage excluded), respectively. Three possible reasons were considered to be responsiblefor the differences observed: (i) a large fraction of fine particle nitrate evaporated from theBLPI and a smaller amount from the FPs (ii) the denuder systems collected coarse particlesinefficiently and, possibly iii) the VI may have collected a small amount of gaseous nitricacid indistinguishable from nitrate.
3.7.1. Nitrate evaporation in the B¸PI. Figure 5 shows the fine and coarse particle nitrateconcentrations as measured by the VI and the BLPI. The two instruments showed good
Nordic intercomparison of major atmospheric nitrogen species 255
Fig. 5. Fine and coarse particle nitrate as measured by the VI and the BLPI (N, kg m~3).
agreement for Na` and SO2~4
, which suggests that there were no problems with thesampling efficiencies. Figure 5 indicates a good agreement for the coarse particle nitrate(VI: 2.5(EAD(15 km; BLPI 2.0(EAD(15 km), but about half of the fine particle(VI: EAD(2.5 km; BLPI: 0.03(EAD(2.0 km) nitrate evaporated from the BLPI. Thesmall difference in the particle size cut-off of the VI and BLPI has practically no influenceon the conclusions drawn from this comparison.
Using this data, Kerminen et al. (1997) calculated theoretically that at the end of theBLPI sampling periods the atmospheric conditions favored the gaseous form of ammoniumnitrate except for samples 1 and 6. Thus, for samples 2, 3, 4 and 5, the ammonium nitrateaccumulated during sampling may have partly evaporated by the end of the sampling.Figure 1 supports these calculations because only samples 1 and 6 show a pronounced fineparticle mode for nitrate. On average, the evaporative loss of nitrate from the BLPI wasabout 50% for fine particles and about 27% for nitrate below 15 km EAD. These values areclearly higher than those of about 10—20% reported by Wall et al. (1988) and Zhang andMcMurry (1992) for atmospheric conditions in California. The higher mass concentrationsof atmospheric particles and shorter sampling periods in the Californian studies lead tothicker particle deposits and shorter time available for evaporation, which both inhibitevaporation from BLPI. Further the longer sampling periods in the Helsinki study allow forgreater temperature and humidity changes. Nitrate evaporation may also be enhanced if theaerosol is acidic. Ion balances for individual impactor stages presented by Pakkanen (1996)suggest, however, that fine particles left in the impactor were only slightly acidic or neutral.For comparison, the nitrate loss from the parallel VI measurements was also calculated: onaverage about 30% of nitrate was lost from the VI Teflon filters and recollected on the VInylon filters (see Figs 5 and 6). In 1996—1997, simultaneous 24 h VI samples were collected atthree sites in the Helsinki area using the same VI design as in the 1992 study. Concerningnitrate evaporation characteristics, the 1996—1997 measurements were highly consistent forthe parallel samples at all the three sites, but the sample to sample differences were large. Onaverage, about 50% of nitrate evaporated from the Teflon filters (and were recollected onthe nylon filters) which means that when calculated as ammonium nitrate, about 9% ofPM
2.5was lost.
3.7.2. Collection efficiency of the denuder systems. The denuder systems had low flowrates (except FMI.ADS, see Table 1) and collected aerosol faced down which usually resultsin poor transport efficiencies for coarse particles. Thus, it is likely that the denuder systems
256 T. A. Pakkanen et al.
Fig. 6. Nitrate in the nylon filters and atmospheric nitric acid as N, kg m~3
did not collect the largest nitrate particles. The VI and the BLPI were equipped withUniversity of Minnesota—type inlets which are designed for the sampling of particles up to15 km EAD (Liu and Pui, 1981). The VI results indicate that the atmospheric concentra-tions of fine and coarse particle nitrate were similar, which underlines the importance ofcoarse particle sampling efficiency. Using the BLPI size distributions it was calculated thatthe denuder systems did not efficiently collect particles larger than about 5.6 km EAD. Thisestimation of 5.6 km can be compared to theoretical calculations of Ferm (1986): theaverage wind speed during the intercomparison was 3.5 m s~1 which leads to the average50% cut-off of about 7.2 km for the IVL denuders when the particle density is estimated tobe 1 g cm~3. Considering that the density of sea-salt and soil particles is about 2 g cm~3, theagreement between the two methods is good. The FPs measured more nitrate than the DSsin seven cases out of 11 which gives some support for the estimation that the 50% cut-offsize of the FP samplers was slightly higher than that of the DSs. Also Harrison and Kitto(1990) observed slightly better particulate sampling efficiencies for their FP instrument thanfor their DS sampler.
3.7.3. Possible collection of nitric acid by the »Is. John et al. (1988) reported 100%condensation of nitric acid on oxidised aluminum surfaces of a VI instrument. Similarly, itcan be expected that nitric acid, being a highly condensable gas, condensed efficiently on theinner stainless-steel surfaces of the VI used in this study. Figure 6 indicates the measuredatmospheric nitric acid concentrations and the amounts of nitrate found on the nylon filtersof the VI and FMI.ADS (see also Table 1). The sodium carbonate denuders of theFMI.ADS removed practically all nitric acid from the collected air stream. Since Fig. 6indicates that the amount of nitrate on the nylon filter is similar for both FMI.ADS and VI,the amount of gaseous atmospheric nitric acid collected by the VI nylon filters has to besmall or negligible.
3.8. ¹otal nitrate
Table 3 and Fig. 4E show the summed concentrations of nitric acid and nitrate ("totalnitrate) as kg Nm~3. The overall agreement was good for the 24 h measurements: the ratiosof the average filter pack values to the average denuder system values ranged from 0.88 to1.06 with an average of 0.97. Also the results obtained with individual sampling instrumentsagreed well (Pakkanen et al., 1994). One of the filter packs used was identical to thatrecommended by EMEP.
Nordic intercomparison of major atmospheric nitrogen species 257
Table 5. Statistical data from the comparison between NaOH, Na2CO
3and NaCl coated denuders. The inlet
NO~3
content in the Na2CO
3-coated denuders is not included. ‘‘Total’’ refers to the sum of filter and denuder tube
content
Slope Int.Mean (kg N m~3) sign.* sign.*
Number Corr. diff. diff.NaOH Na
2CO
3NaCl of obs. coeff. Slope from 1 Intercept from 0
Total NO~3
0.37 — 0.35 12 0.947 0.99 No 0.02 No0.37 0.38 — 12 0.927 0.84 No 0.05 No— 0.37 0.35 13 0.937 1.19 No !0.04 No
Particle NO~3
0.18 — 0.19 12 0.929 1.13 No !0.04 No0.18 0.19 — 12 0.928 0.94 No !0.00 No— 0.19 0.18 13 0.964 1.18 No !0.03 No
Gaseous HNO3
0.20 — 0.16 13 0.935 1.34 Yes !0.02 No0.20 0.19 — 13 0.859 1.43 Yes !0.07 No— 0.19 0.16 13 0.900 0.96 No 0.02 No
Total NO~2
0.14 — 0.16 13 0.948 1.05 No !0.03 No0.14 0.11 — 13 0.926 0.99 No 0.04 Yes— 0.11 0.16 13 0.934 1.06 No !0.07 Yes
Total NO~3#NO~
20.50 — 0.51 12 0.962 1.06 No !0.03 No0.50 0.48 — 12 0.966 1.01 No 0.03 No— 0.49 0.51 13 0.963 1.08 No !0.06 No
*At the 95% confidence level.
Table 4. Type of denuder coating and filter impregnation for sampling of HNO3/NO~
3
Coating tube Coating inlet Impregnation filter
NaOH 1% (w/v) in EtOH — NaOH 1% (w/v) in EtOHNaCl 0.5% (w/v) in H
2O/MeOH 1:9 — NaOH 1% (w/v) in EtOH
NaCl 0.5% (w/v) in H2O/MeOH 1:9 H
3PO
41% (v/v) H
3PO
4NaOH 1% (w/v) in EtOH
(85%) in MeOHNa
2CO
31% (w/v) in H
2O/MeOH 1:1 H
3PO
41% (v/v) H
3PO
4Na
2CO
31% (w/v) in
(85%) in MeOH H2O/MeOH 1 :1
3.9. Discussion about interferences in collection of nitric acid
3.9.1. Different coatings for HNO3/NO~
3sampling. The denuder is generally considered
to give the best separation of gases and particles, although some problems might occur.Interfering gases and/or particle deposition in the denuder tubes are factors which may leadto potential overestimation of the HNO
3concentration. Evaporation of HNO
3from
particles passing the denuder tube has also been discussed, although this seems to bea minor problem (Appel and Tokiwa, 1981; Larson and Taylor, 1983; Eatough et al., 1985;Harrison et al., 1990).
A set of identical denuder tubes, with three different types of coatings and with andwithout an acid coated inlet, were run by the DMU during the intercomparison (Table 4).The type of coating of the denuder tube has an influence on potential interferences. Datawas obtained by NaOH, Na
2CO
3and NaCl coated denuders. The inlet of the Na
2CO
3coated denuder was coated with H
3PO
4. The results have been analyzed statistically by
principal component analysis and are presented in Table 5. Further, the Na2CO
3coated
denuder was followed by a Na2CO
3-impregnated filter, while the other denuders were
followed by a NaOH-impregnated filter. This makes direct comparison of the total amountsof nitrate difficult.
3.9.2. Overestimation of HNO3due to interfering gases. Figure 7 shows the comparison of
total NO~3, particulate NO~
3and gaseous HNO
3for the different coatings. For the total
amount and for the particulate NO~3
no significant differences were seen between the
258 T. A. Pakkanen et al.
Fig. 7. HNO3
and NO~3
from denuders with different coatings.
different coatings (95% confidence level, see Table 5). For the gaseous HNO3, the NaOH
coated denuder measured significantly higher values than both the Na2CO
3and the
NaCl-coated denuders (95% confidence level). There was no difference between Na2CO
3and NaCl-coated denuders in the HNO
3determination, though due to the H
3PO
4-coated
inlet of the Na2CO
3-coated denuder, which reduces both the absorbing area for HNO
3and
the potential contribution of deposited NO~3
containing particles, these two denuder typesare not directly comparable here.
The difference in HNO3
determination between NaOH and NaCl-coated denuders isexpected to arise from interfering gases, since particle deposition must be assumed to beequal for the two denuders, independent of the coating. In the NaOH or Na
2CO
3coated
denuder NO2
and peroxyacetyl nitrate (PAN) might be potential interfering gases, but intests carried out no or very little interference was observed (Ferm, 1986). Koutrakis et al.(1988) found an artifact formation of NO~
3and NO~
2, representing about 5—10% of the total
amount of these species, in a Na2CO
3coated annular denuder. From laboratory experi-
ments for the same type of denuder as used here, Ferm and Sjodin (1985) found that NO2
alone did not constitute an interference of any major importance, but NO and NO2
together might form HNO2
during humid conditions. One could expect an error in theHNO
3determination, if the interfering NO~
2oxidizes to NO~
3either in the denuder or in
the denuder extract. Febo et al. (1986) suggested that during sampling in photochemicalsmog episodes NO~
2might be oxidized to NO~
3, probably by O
3. Perrino et al. (1990) also
found evidence for the oxidation of sampled NO~2
. Dasch et al. (1989) reported that evenadding H
2O
2to the denuder extracts did not oxidize NO~
2to NO~
3. When sampling by
Nordic intercomparison of major atmospheric nitrogen species 259
Fig. 8. NO~2
on denuder tube and filter.
Na2CO
3-coated annular denuders, Appel et al. (1990) found a low percentage retention of
NO2, PAN and other possible pollutants.
The extracts from both gaseous and particulate determinations of NO~3
were analyzedalso for NO~
2. Figure 8 shows the total (tube#filter), tube and filter content of NO~
2
260 T. A. Pakkanen et al.
separately. The NO~2
might originate from HNO2
and/or some interfering gases. TheNaCl-coated denuder does not sample NO~
2(Fig. 8) and therefore the possibility of errors
in HNO3
determination due to oxidized NO~2
in the tube or extract can be excluded.Table 5 presents the comparison of NO~
2sampled by different types of denuder coatings
followed by filters with different impregnations. For the total amount of NO~2
, a very goodcorrelation was found, and no significant differences were observed between the NaOH andNaCl coatings, both followed by NaOH-impregnated filters. If the NO~
2originates from
interfering gases this interference therefore seems independent of the coating used. Thedifference in HNO
3determination between NaOH and NaCl coatings could originate from
oxidized NO~2, especially since there is no difference in total NO~
3plus NO~
2. Figure
8 shows the difference between the total amount of NO~2
in the NaCl and NaOH-coateddenuders versus the difference in HNO
3determination between the NaOH and NaCl-
coated denuders. If a few outliers are excluded, there might be some evidence for a correla-tion indicating that sampled NO~
2on the NaOH coating is oxidized to NO~
3and
consequently interpreted as HNO3
even though the differences are insignificant. Thedifference in HNO
3determination by the NaCl and NaOH-coated denuders does not
correlate to the amount of NO~2
in the NaOH tube. However, the oxidized amountprobably depends on the O
3level amongst other factors. The sampling periods for which
the largest difference in HNO3
concentrations between the NaOH and NaCl coatings wereobserved had either high O
3levels or a high NO~
2content in the NaOH tube (Pakkanen et
al., 1994). The difference in HNO3
determination between the coatings might therefore bea consequence of a number of parameters acting differently during the various climate andpollution climate conditions and as such are very difficult to identify.
4 . SUMMARY AND CONCLUSIONS
Nitrate size distributions, biased by evaporation of fine particle nitrate, exhibited one ortwo fine particle modes and two overlapping coarse particle modes. According to the virtualimpactor results, about 25—40% of nitrate was in the coarse particle mode. Ammonium hadtwo fine particle and two coarse particle modes. The Berner low-pressure impactor samplesindicated that only 1.5—4.8% of ammonium was contained in coarse particles and in severalcases the virtual impactor showed even lower percentages.
The overall agreement between denuder systems and filter packs was on average withinabout 10% for all the measured components: ammonia, ammonium, total ammonium,nitric acid, nitrate and total nitrate. However, in the calculation of the above averages someindividual measurements were excluded as outliers, especially for ammonia. For am-monium, the virtual impactor and the Berner low-pressure impactor data agreed well withthe denuder systems and the filter packs.
The virtual impactor collected on average 37% more particulate nitrate than the Bernerlow-pressure impactor (BLPI), indicating evaporation of about 50% of fine particle nitrate(&27% of total nitrate) from the BLPI. Considering that nitrate evaporates as ammoniumnitrate a considerable fraction of PM
2.5may be lost in BLPI measurements. Compared to
the average denuder system values, the virtual impactor gave on average 17% higher nitrateconcentrations. Most of this difference can be explained by inefficient transport of coarseparticle nitrate into the denuder systems. Further the virtual impactor collected on average24% more nitrate than the filter packs: this difference was considered to be due to theslightly lower sampling efficiencies for coarse particles and the possible evaporative nitratelosses in the filter packs. Using the BLPI size distributions, it was computed that particleslarger than about 5.6 km EAD were not efficiently sampled by the denuder systems used.While calculating the above percentages some high values were excluded because, duringperiods of high nitric acid and low nitrate concentrations, the virtual impactor may havecollected a reasonable percentage of nitric acid indistinguishable from nitrate. Moreexperiments are needed to verify the denuding efficiences of the stainless steel VI and thestainless-steel inlet for nitric acid.
Nordic intercomparison of major atmospheric nitrogen species 261
The NaOH coating of the denuder for HNO3/NO~
3determination gave an overestima-
tion of about 30% compared to the NaCl coating. This overestimation was probably due tooxidized NO~
2, originating from HNO
2, NO
2, NO, PAN or other interfering gases. There
were also differences between the NaOH and Na2CO
3coated denuders.
Acknowledgements—The Nordic Council of Ministers is acknowledged for their financial support which made thisintercomparison possible. Also the Maj and Tor Nessling foundation and the Academy of Finland are acknow-ledged for their financial support. We thank all the participants of the Nordic intercomparison study for theircontribution and Mr. Ari Halm, Mr. Jukka Kiiski, Mr. Mauri Hypponen, and Mrs. Mirva Vuori from the FMI fortheir help in setting up the instruments and the measurement platforms.
REFERENCES
Andersen H. V. and Hilbert, G. (1993) Measurements of NH3/NH`
4and HNO
3/NO~
3by denuder and filter pack.
NERI-Report no. 73, National Environmental Research Institute, DK-4000 Roskilde, Denmark, p. 67.Andersen, H. V. and Hovmand M. F. (1994) Measurements of ammonia and ammonium by denuder and filter
pack. Atmos. Envir. 28, 3495—3512.Appel, B. R. and Tokiwa, Y. (1981) Atmospheric particulate nitrate sampling errors due to reactions with
particulate and gaseous strong acids. Atmos. Envir. 15, 1087—1089.Appel, B. R., Winer, A. M., Tokiwa, Y. and Biermann, H. W. (1990) Comparison of atmospheric nitrous acid
measurements by annular denuder and differential optical absorption systems. Atmos. Envir. 24A, 611—616.Benner, C. L., Eatough, J. E., Eatough, N. L. and Bhardwaja, P. (1991) Comparison of annular denuder and filter
pack collection of HNO3(g), HNO
2(g), SO
2(g) and particulate-phase nitrate, nitrite and sulfate in the South-
West desert. Atmos. Envir. 25A, 1537—1545.Berner, A. and Lurzer, C. (1980) Mass size distributions of traffic aerosols at Vienna. J. Phys. Chem. 84, 2079—2083.Dasch, J. M., Cadle, S. E., Kennedy, K. G. and Mulawa, P. A. (1989) Comparison of annular denuders and filter
packs for atmospheric sampling. Atmos. Envir. 23, 2775—2782.Eatough, D. J., White, V. F., Hansen, L. D., Eatough, N. L. and Ellis, E. C. (1985) Hydration of nitric acid and its
collection in the atmosphere by diffusion denuders. Analytical Chemistry 57, 743—748.Eatough, N. L., McGregor, S., Lewis, E., Eatough, D. J., Huang, A. A. and Ellis, E. C. (1988) Comparison of six
denuder methods and a filter pack for the collection of ambient HNO3(g), HNO
2(g) and SO
2in 1985 NSMC
study. Atmos. Envir. 22, 1601—1618.Febo, A., De Santis, F. and Perrino, C. (1986) Measurement of atmospheric nitrous and nitric acid by means of
annular denuders. Physio chemical behaviour of atmospheric pollutants. Proc. 4th European Symp., Stresa, Italy,23—25 September, pp. 121—125. D. Reidel, Dordrecht.
Ferm, M. (1979) Method for determination of atmospheric ammonia. Atmos. Envir. 13, 1385—1393.Ferm, M. and Sjodin, A_ . (1985) A sodium carbonate coated denuder for determination of nitrous acid in the
atmosphere. Atmos. Envir. 19, 979—983.Ferm, M. (1986a) Concentration measurements and equilibrium studies of ammonium, nitrate and sulphur species
in air and precipitation. Ph.D. thesis, ISBN 91-7900-006-1.Ferm, M. (1986) A Na
2CO
3-coated denuder and filter for determination of gaseous HNO
3and particulate NO~
3in
the atmosphere. Atmos. Envir. 20, 1193—1201.Ferm, M., Areskoug, H., Hanssen, J. E., Hilbert, G. and Lattila, H. (1988) Field intercomparison of measurement
techniques for total NH`4
and total NO~3
in ambient air. Atmos. Envir. 22, 2275—2281.Ferm, M. and Sjodin, A_ . (1992) Proposal of an impregnated filter technique for monitoring of NO
2at EMEP
stations. Proc. EMEP workshop on Measurements of Nitrogen-Containing Compounds (Edited by R. Ballmanet al.), Les Diablerets, Switzerland, 29 June—3 July, 1992, pp. 173—181.
Ferm, M. (1993) Throughfall measurements of nitrogen and sulphur compounds. Int. J. Anal. Chem. 50, 29—43.Harrison, R. M., Sturges, W. T., Kitto, A.-M. N. and Li, Y. (1990) Kinetics of evaporation of ammonium chloride
and ammonium nitrate aerosols. Atmos. Envir. 24A, 1883—1888.Harrison, R. M. and Kitto, A.-M. N. (1990) Field intercomparison of filter pack and denuder sampling methods for
reactive gaseous and particulate pollutants. Atmos. Envir. 24A, 2633—2640.Hering, S. V., Lawson, D. R., Allegrini, I., Febo, A., Perrino, C., Possanzini, M., Sickles, J. E., Anlauf, K. G., Wiebe,
A., Appel, B. R., John, W., Ondo, J., Wall, S., Braman, R. S., Sutton, R., Cass, G. R., Solomon, P. A., Eatough,D. J., Eatough, N. L., Ellis, E. C., Grosjean, D., Hicks, B. B., Womack, J. D., Horrocks, J., Knapp, K. T., Ellestad,T. G., Paur, R. J., Mitchell, W. J., Pleasant, M., Peake, E., MacLean, A., Pierson, W. R., Brachaczek, W., Schiff,H. I., Mackay, G. I., Spicer, C. W., Stedman, D. H., Winer, A. M., Biermann, H. W. and Tuazon, E. C. (1988) Thenitric acid shootout: field comparison of measurement methods. Atmos. Envir. 22, 1519—1540.
Hillamo, R. E. and Kauppinen, E. I. (1991) On the performance of the Berner low pressure impactor. Aerosol Sci.¹echnol. 14, 33—47.
John, W., Wall, S. M. and Ondo, J. L. (1988) A new method for nitric acid and nitrate aerosol measurement usingdichotomous sampler. Atmos. Envir. 22, 1672—1635.
John, W., Wall, S. M., Ondo, J. L. and Winklmayr, W. (1990) Modes in the size distributions of atmosphericinorganic aerosol. Atmos. Envir. 24A, 2349—2359.
Kerminen, V.-M., Pakkanen, T. A. and Hillamo, R. E. (1997) Interactions between inorganic trace gases andsupermicrometer particles at a coastal site. Atmos. Envir. 31, 2753—2765.
Koutrakis, P., Wolfson, J. M., Slater, J. L., Brauer, M., Spengler, J. D., Stevens, R. K. and Stone, C. L. (1988)Evaluation of an annular denuder/filter pack system to collect acidic aerosols and gases. Envir. Sci. ¹echnol. 22,1463—1468.
262 T. A. Pakkanen et al.
Larson, T. V. and Taylor, G. S. (1983) On the evaporation of ammonium nitrate aerosol. Atmos. Envir. 17,2489—2495.
Liu, B. Y. H and Pui, D. Y. H. (1981) Aerosol sampling inlets and inhalable particles. Atmos. Envir. 15, 589—600.Loo, B. W. and Cork, C. P. (1988) Development of high efficiency virtual impactors. Aerosol Sci. ¹echnol. 9,
167—176.Pakkanen, T. A., Hillamo, R. E., Makinen, M., Makela, T., Kerminen, V.-M., Virkkula, A., Karlsson, V., Reissell,
A., Lattila, H., Boij, H., Hilbert, G., Grundahl, L., Andersen, H. V., Christensen, L., Ferm, M., Persson, K.,Fl+isand, I., R+yset, O., Schaug, J., T+rset, K., Oyola, P., Ganko, T., Carlsson, H., Rosman, K., Vesely, V. andGranat, L. (1994) Nordic HNO
3/NO~
3and NH
3/NH`
4gas/particle intercomparison in Helsinki, 11—22 May
1992. Publications on Air Quality no. 18, Finnish Meteorological Institute.Pakkanen, T. A. (1996) Study of formation of coarse particle nitrate aerosol. Atmos. Envir. 30, 2475—2482.Pakkanen, T. A., Kerminen, V.-M., Hillamo, R. E., Makinen, M., Makela, T. and Virkkula, A. (1996) Distribution
of nitrate over sea-salt and soil derived particles—implications from a field study. J. Atmos. Chem. 24, 189—205.Perrino, C., De Santis, F. and Febo, A. (1990) Criteria for the choice of a denuder sampling technique devoted to
the measurement of atmospheric nitrous and nitric acids. Atmos. Envir. 24A, 617—626.Pio, C. A. (1992) Measurement of ammonia and ammonium in the atmosphere by denuder and filter pack methods.
Evaluation of the Rome Field Intercomparison Exercise. In: Development of Analytical ¹echniques for Atmo-spheric Pollutants (Edited by Allegrini, I.), Air Pollution Research Report 41, pp. 239—252. Commission ofEuropean Communities, Brussels.
Seinfeld, J. H. (1986) Atmospheric Chemistry and Physics of Air Pollution. Wiley, New York.Wall, S. M., John, W. and Ondo, J. L. (1988) Measurement of aerosol size distributions for nitrate and major ionic
species. Atmos. Envir. 22, 1649—1656.Wolfenbarger, J. K. and Seinfeld, J. H. (1990) Inversion of aerosol size distribution data. J. Aerosol Sci. 21,
227—247.Wolfenbarger, J. K. and Seinfeld, J. H. (1991) Regularized solutions to the aerosol data inversion problem. SIAM J.
Sci. Statist. Comput. 12, 342—361.Yoshizumi, K. and Hoshi, A. (1985) Size distributions of ammonium nitrate and sodium nitrate in atmospheric
aerosols. Envir. Sci. ¹echnol. 19, 258—261.Zhang, X. and McMurry, P. H. (1992) Evaporative losses of fine particulate nitrates during sampling. Atmos. Envir.
26A, 3305—3312.
Nordic intercomparison of major atmospheric nitrogen species 263