Seven Dials, Covent GardenCalculation to show lighting levelsProject code: 08-658Date: 23-10-2008Customer: Seven Dials - David BiedaCustomer Representative: Alastair Aiken
Designer: Steve Johnston
Description: Design to show lighting levels and spread if lighting using New recessed Decoscene & Column Mounted LED Beamer luminaireMF 0.8Best Results: 4 No Decoscene DBP522 70w CDM-T/940 NB HMG-FR luminaires with Half Moon Frosted Glass
3 No Led Beamers with 2 deg beam mounted on 10m cols aiming up at Sundial Facesup to Sundials BCP725 1xLED LXN III-LB/WH 2-RND.1st 1m of Column will not be lit due to shadow of Plinth.
CalcuLuX Area 6.7.2 E-Mail: [email protected] Phone: 07917 591561Telephone: 020 8644 3164
PhilipsCentreGuildford Business ParkGuildfordSurreyGU2 8XH
Philips Lighting
The nominal values shown in this report are the result of precision calculations, based upon precisely positioned luminaires in a fixed relationship to each other and to the area under examination. In practice the values may vary due to tolerances on luminaires, luminaire positioning, reflection properties and electrical supply.
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
Table of Contents
1. Project Description 3
1.1 3-D Project Overview 31.2 Top Project Overview 41.3 Left Project Overview 51.4 Right Project Overview 61.5 Front Project Overview 7
2. Summary 8
2.1 General Information 82.2 Obstacle Information 82.3 Project Luminaires 82.4 Calculation Results 9
3. Calculation Results 10
3.1 Vert Plinth Grid: Graphical Table 103.2 Vert Plinth Grid: Iso Contour 113.3 Vert Plinth Grid: Filled Iso Contour 123.4 Column: Graphical Table 133.5 Column: Iso Contour 143.6 Column: Filled Iso Contour 153.7 Sundial: Graphical Table 163.8 Sundial: Iso Contour 173.9 Sundial: Filled Iso Contour 18
4. Luminaire Details 19
4.1 Project Luminaires 19
5. Installation Data 21
5.1 Legends 215.2 Luminaire Positioning and Orientation 21
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 2/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
1. Project Description
1.1 3-D Project Overview
G DBP522 NB + HMG-FR O BCP725 2-RND
O
O
O
G
G
GG
X
YZ
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 3/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
1.2 Top Project Overview
G DBP522 NB + HMG-FR O BCP725 2-RND
-45 -35 -25 -15 -5 5 15 25 35 45 55
X(m)
-25
-15
-55
1525
Y(m
)
O
O
O
G
G
GG
Scale1:400
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 4/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
1.3 Left Project Overview
G DBP522 NB + HMG-FR O BCP725 2-RND
26 21 16 11 6 1 -4 -9 -14 -19 -24
Y(m)
-6-1
49
1419
Z(m
)
OO O
GG GG
Scale1:200
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 5/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
1.4 Right Project Overview
G DBP522 NB + HMG-FR O BCP725 2-RND
-26 -21 -16 -11 -6 -1 4 9 14 19 24
Y(m)
-6-1
49
1419
Z(m
)
O OO
G GGG
Scale1:200
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 6/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
1.5 Front Project Overview
G DBP522 NB + HMG-FR O BCP725 2-RND
-20 -15 -10 -5 0 5 10 15 20 25 30
X(m)
-6-1
49
1419
Z(m
)
OO O
GG GG
Scale1:200
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 7/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
2. Summary
2.1 General Information
The overall maintenance factor used for this project is 0.80.
2.2 Obstacle Information
Obstacle
Base PlinthBase plinth edgePlinth above base edgePinth below PillarColumnEdge below PillarEdge above pillarColumn below SundialColumn above top edgeSundialTop SpikeColumn 1Column 2Column 3
Transparency (%)Transparency (%)
0 0
0
0 0 0 0
0
0
0 0 0 0 0
X (m)-1.50-1.55
-1.00
-0.85 0.00-1.00-0.75
0.00
0.00
-0.35 0.00
-15.00-15.0025.00
Y (m)-1.50-1.55
-1.00
-0.85 0.00-1.00-0.75
0.00
0.00
-0.35 0.0020.00
-20.00 0.00
PositionZ (m) 0.00 0.50
0.52
0.72 3.70 3.50 9.70
10.00
9.80
10.2011.00 0.00 0.00 0.00
2.3 Project Luminaires
CodeGO
QtyQty43
Luminaire TypeLuminaire TypeDBP522 NB + HMG-FRBCP725 2-RND
Lamp TypeLamp Type1 * CDM-T70W1 * LED-LXHL-III-LB/WH
Power (W)Power (W) 86.2 3.0
Flux (lm)Flux (lm)1 * 66001 * 65
The total installed power: 0.35 (kWatt)
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 8/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
2.4 Calculation Results
(Il)luminance Calculations:CalculationVert Plinth GridColumnSundial
TypeTypeSurface IlluminanceSurface IlluminanceSurface Illuminance
UnitUnitluxluxlux
AveAve 52.1 97.2 14.1
MinMin 0.0 0.0 7.6
Min/AveMin/Ave0.000.000.54
Obtrusive Light Calculations:The upward light ratio (ULR) is 1.00.
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 9/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
3. Calculation Results
3.1 Vert Plinth Grid: Graphical Table
Grid : Vert Plinth Grid at X = 0.86 mCalculation : Surface Illuminance (lux)
Average Minimum Min/Ave Project maintenance factor 52.1 0.0 0.00 0.80
G DBP522 NB + HMG-FR O BCP725 2-RND
-3.8 -3.3 -2.8 -2.3 -1.8 -1.3 -0.8 -0.3 0.2 0.7 1.2 1.7 2.2 2.7 3.2 3.7
Y(m)
0.4
0.9
1.4
1.9
2.4
2.9
3.4
Z(m
)
0
43
41
39
36
37
37
38
40
43
47
35
0
0
68
62
55
52
47
46
46
49
53
58
62
0
0
88
86
78
71
68
66
66
73
81
91
103
0
0
100
95
88
77
75
70
71
76
84
94
107
0
0
88
86
78
71
68
66
66
73
81
91
103
0
0
68
62
55
52
47
46
46
49
53
58
62
0
0
43
41
39
36
37
37
38
40
43
47
35
0
Scale1:30
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 10/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
3.2 Vert Plinth Grid: Iso Contour
Grid : Vert Plinth Grid at X = 0.86 mCalculation : Surface Illuminance (lux)
Average Minimum Min/Ave Project maintenance factor 52.1 0.0 0.00 0.80
G DBP522 NB + HMG-FR O BCP725 2-RND
-3.8 -3.3 -2.8 -2.3 -1.8 -1.3 -0.8 -0.3 0.2 0.7 1.2 1.7 2.2 2.7 3.2 3.7
Y(m)
0.4
0.9
1.4
1.9
2.4
2.9
3.4
3.9
Z(m
)
20
20
40
40
40
40
60
60
60
60
60
80
80
80
80
100
Scale1:30
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 11/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
3.3 Vert Plinth Grid: Filled Iso Contour
Grid : Vert Plinth Grid at X = 0.86 mCalculation : Surface Illuminance (lux)
Average Minimum Min/Ave Project maintenance factor 52.1 0.0 0.00 0.80
G DBP522 NB + HMG-FR O BCP725 2-RND
100
80
60
40
20
-2.8 -2.3 -1.8 -1.3 -0.8 -0.3 0.2 0.7 1.2 1.7 2.2 2.7
Y(m)
0.4
0.9
1.4
1.9
2.4
2.9
3.4
3.9
Z(m
)
Scale1:30
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 12/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
3.4 Column: Graphical Table
Grid : Column at X = 0.61 mCalculation : Surface Illuminance (lux)
Average Minimum Min/Ave Project maintenance factor 97.2 0.0 0.00 0.80
G DBP522 NB + HMG-FR O BCP725 2-RND
-9.5 -8.5 -7.5 -6.5 -5.5 -4.5 -3.5 -2.5 -1.5 -0.5 0.5 1.5 2.5 3.5 4.5 5.5 6.5 7.5 8.5 9.5
Y(m)
2.5
3.5
4.5
5.5
6.5
7.5
8.5
9.5
10.5
Z(m
)
O
66
70
74
78
81
83
84
83
79
76
80
83
85
87
87
86
82
76
69
70
69
0
0
0
0
91
98
105
112
119
125
129
132
133
130
124
113
100
103
105
106
105
101
94
81
82
0
0
0
0
114
124
136
147
157
165
172
176
178
177
173
164
149
126
115
118
118
117
112
102
90
0
0
0
0
127
142
160
182
187
191
195
198
199
197
192
184
169
148
118
121
123
122
118
109
93
0
0
0
0
114
124
136
147
157
165
172
176
178
177
173
164
149
126
115
118
118
117
112
102
90
0
0
0
0
91
98
105
112
119
125
129
132
133
130
124
113
100
103
105
106
105
101
94
81
82
0
0
0
0
66
70
74
78
81
83
84
83
79
76
80
83
85
87
87
86
82
76
69
70
69
0
0
0
0
Scale1:75
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 13/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
3.5 Column: Iso Contour
Grid : Column at X = 0.61 mCalculation : Surface Illuminance (lux)
Average Minimum Min/Ave Project maintenance factor 97.2 0.0 0.00 0.80
G DBP522 NB + HMG-FR O BCP725 2-RND
-9.5 -8.5 -7.5 -6.5 -5.5 -4.5 -3.5 -2.5 -1.5 -0.5 0.5 1.5 2.5 3.5 4.5 5.5 6.5 7.5 8.5 9.5
Y(m)
2.5
3.5
4.5
5.5
6.5
7.5
8.5
9.5
10.5
Z(m
)
50100
100
1 00
1 50
15 0
O
Scale1:75
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 14/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
3.6 Column: Filled Iso Contour
Grid : Column at X = 0.61 mCalculation : Surface Illuminance (lux)
Average Minimum Min/Ave Project maintenance factor 97.2 0.0 0.00 0.80
G DBP522 NB + HMG-FR O BCP725 2-RND
150
100
50
-7 -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 7
Y(m)
2.5
3.5
4.5
5.5
6.5
7.5
8.5
9.5
10.5
Z(m
)
O
Scale1:75
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 15/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
3.7 Sundial: Graphical Table
Grid : Sundial at X = 0.36 mCalculation : Surface Illuminance (lux)
Average Minimum Min/Ave Project maintenance factor 14.1 7.6 0.54 0.80
G DBP522 NB + HMG-FR O BCP725 2-RND
-3.2 -2.7 -2.2 -1.7 -1.2 -0.7 -0.2 0.3 0.8 1.3 1.8 2.3 2.8
Y(m)
9.2
9.7
10.2
10.7
11.2
11.7
Z(m
)
8
10
12
13
13
12
9
10
13
16
17
17
15
11
11
15
18
20
19
17
13
11
15
19
2020
17
14
11
15
18
20
19
17
13
10
13
16
17
17
15
11
8
10
12
13
13
12
9
Scale1:25
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 16/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
3.8 Sundial: Iso Contour
Grid : Sundial at X = 0.36 mCalculation : Surface Illuminance (lux)
Average Minimum Min/Ave Project maintenance factor 14.1 7.6 0.54 0.80
G DBP522 NB + HMG-FR O BCP725 2-RND
-3.2 -2.7 -2.2 -1.7 -1.2 -0.7 -0.2 0.3 0.8 1.3 1.8 2.3 2.8
Y(m)
9.2
9.7
10.2
10.7
11.2
11.7
Z(m
)
10
10
1010
12.5
12.5
12.5
15 15
15
17.5
20
Scale1:25
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 17/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
3.9 Sundial: Filled Iso Contour
Grid : Sundial at X = 0.36 mCalculation : Surface Illuminance (lux)
Average Minimum Min/Ave Project maintenance factor 14.1 7.6 0.54 0.80
G DBP522 NB + HMG-FR O BCP725 2-RND
20
17.5
15
12.5
10
-2.4 -1.9 -1.4 -0.9 -0.4 0.1 0.6 1.1 1.6 2.1
Y(m)
9.2
9.7
10.2
10.7
11.2
11.7
Z(m
)
Scale1:25
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 18/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
4. Luminaire Details
4.1 Project Luminaires
DecoScene DBP522 1xCDM-T70W/830 NB + HMG-FR
Light output ratios DLOR : 0.69 ULOR : 0.00 TLOR : 0.69Ballast : StandardLamp flux : 6600 lmLuminaire wattage : 86.2 WMeasurement code : LVM0729500
10000
0o 30o30o
60o 60o
90o 90o
120o 120o150o 150o180o
C = 180o C = 0o C = 270o Imax C = 90o
Luminous Intensity Diagram (candela/1000 lumen)
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 19/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
BeamerLED BCP725 1xLED-LXHL-III-LB/WH 2-RND
Light output ratios DLOR : 0.50 ULOR : 0.00 TLOR : 0.50Ballast : N/ALamp flux : 65 lmLuminaire wattage : 3.0 WMeasurement code : LVMA633500
50000
0o 30o30o
60o 60o
90o 90o
120o 120o150o 150o180o
C = 180o Imax C = 0o C = 270o C = 90o
Luminous Intensity Diagram (candela/1000 lumen)
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 20/21
Seven Dials, Covent Garden Philips Lighting08-658 Calculation to show lighting levels Date: 23-10-2008
5. Installation Data
5.1 Legends
Project Luminaires:CodeGO
QtyQty43
Luminaire TypeLuminaire TypeDBP522 NB + HMG-FRBCP725 2-RND
Lamp TypeLamp Type1 * CDM-T70W1 * LED-LXHL-III-LB/WH
Flux (lm)Flux (lm)1 * 6600
1 * 65
5.2 Luminaire Positioning and Orientation
Qty and Code
1 * O1 * O1 * G1 * G1 * G 1 * G1 * O
X (m)
-15.00-15.00-2.50-0.00-0.00
2.5025.00
Y (m)
-20.0020.00-0.00-2.50 2.50
-0.00-0.00
Position
Z (m)
6.00 6.00 0.01 0.01 0.01
0.01 6.00
Rot.
52.0-52.0180.0-90.0 90.0
0.0
180.0
Tilt90
100.5100.5
-168.0-168.0-168.0
-168.0100.5
Aiming Angles
Tilt0
0.0 0.0 -0.0 0.0 -0.0
0.0 0.0
ULRULR
0.990.991.001.001.00
1.000.99
Philips Lighting B.V. - CalcuLuX Area 6.7.2 Page: 21/21