OKONITE CABLES

127
Bulletin OSC OKONITE CABLES 102 Hilltop Road, Ramsey, New Jersey 07446 Phone 201.825.0300 www.okonite.com THE OKONITE COMPANY STOCK CATALOG In Stock for Immediate Delivery “”

Transcript of OKONITE CABLES

Bulletin OSC

OKONITE CABLES

102 Hilltop Road, Ramsey, New Jersey 07446 Phone 201.825.0300 www.okonite.com• •

THEOKONITECOMPANY

STOCK CATALOGIn Stock for Immediate Delivery

▲“ ”

THE OKONITE COMPANY

INDEX

Data SheetSection:Sheet

GLOSSARY OF TERMS AND DEFINITIONS

MEDIUM VOLTAGE POWER CABLES 2.4kV AND ABOVESingle Conductor CableOkoguard Non-Shielded Okolon TS-CPE Type MV-90 (CT USE) 2.4kV ......................2:2

Okoguard Shielded Okoseal Type MV-105 (CT USE) 5/8kV ........................................2:3

Okoguard Shielded Okoseal Type MV-105 5/8 kV.........................................................2:4

Okoguard Shielded Okoseal Type MV-105 (CT USE) 15kV .........................................2:8

Okoguard Shielded Okoseal Type MV-105 15kV ..........................................................2:9

Okoguard Shielded Okolon TS-CPE Type MV-105 (CT USE) 15kV .............................2:11

Okoguard Shielded Okoseal Type MV-105 35kV...........................................................2:16

Okoguard Shielded Okoseal 69kV ................................................................................2:18

Multi-Conductor CableOkoguard Shielded Okoseal Type MV-105 (CT USE) 3/C 5/8kV ..................................2:19

Okoguard Shielded Okoseal Type MV-105 (CT USE) 3/C 15kV ...................................2:20

Okoguard Non-Shielded C-L-X Type MV-90 or MC-HL (CT USE) 2.4kV ......................2:21

Okoguard Shielded C-L-X Type MV-105 or MC-HL (CT USE) 5/8kV ...........................2:22

Okoguard Shielded C-L-X Type MV-105 or MC-HL (CT USE) 15kV ............................2:24

Solid Type PILC 3/C 15kV..............................................................................................2:31

UNDERGROUND RESIDENTIAL DISTRIBUTION CABLEOkoguard URO-J 15kV Aluminum Conductor ................................................................2:35

Okoguard URO-J 15kV Filled Strand Aluminum Conductor ...........................................2:36

Okoguard URO-J 25kV Aluminum Conductor ................................................................2:39

Okoguard URO-J 35kV Aluminum Conductor ................................................................2:40

Okoguard URO-J 15kV to 35kV Copper Conductor .......................................................2:42

LOW VOLTAGE CABLES TO 2kVSingle Conductor CableOkoguard Okolon TS-CPE Type RHH or RHW-2 or USE-2, VW-1 600V RW-90 .........3:1

Okoguard Okolon TS-CPE Type RHH or RHW-2, 2000V .............................................3:10

Multi-Conductor CableC-L-X Type MC-HL for CT USE (XHHW-2) 600V .........................................................4:1

C-L-X Type MC (XHHW-2) 600V....................................................................................4:2

Okonite-FMR Okoseal Type TC 600V............................................................................4:5

X-Olene - Okoseal Type TC-ER Control Cable (XHHW-2) 600V ...................................4:8

C-L-X Type MC for CT USE (XHHW-2) 600V Control Cable ........................................4:14

C-L-X Type MC-HL for CT USE (XHHW-2) 600V Control Cable ..................................4:15

INDEX

Data SheetSection:Sheet

INSTRUMENTATION CABLESOkoseal Type P-OS 300V .............................................................................................5:2

Okoseal Type P-OS C-L-X 300V ...................................................................................5:3

Type SP-OS Instrumentation Cable ...............................................................................5:13

Okoseal Type SP-OS C-L-X 300V ................................................................................5:14

Okoseal Type P-OS Thermocouple 300V .....................................................................5:18

C-L-X Okoseal Type P-OS Thermocouple 300V............................................................5:19

Okoseal-N Type P-OS 600V .........................................................................................5:29

Okoseal-N Type SP-OS 600V .......................................................................................5:31

Okoseal-N Type P-OS C-L-X Type MC-HL 600V .........................................................5:40

Okoseal-N Type SP-OS C-L-X Type MC-HL 600V ......................................................5:42

Okobus Type PLTC & Type ITC-ER Fieldbus CableSingle Pair Type P-OS — Multi Pair Type SP-OS..........................................................5:47

Okobus C-L-X.................................................................................................................5:48

C-L-X X-Olene P-OS, SP-OS .........................................................................................5:49

X-Olene Okoseal UL Type TC-ER/ITC-ER & cUL Type CIC-TC-ER..............................5:50

SPECIAL PURPOSE CABLESX-Ray Low Noise 65-250kV DC .....................................................................................6:1

X-Ray 65-1000kV DC .....................................................................................................6:2

Okoguard Aerial Jumper Cable 15kV ............................................................................6:4

Okoguard-Okolon TS-CPE 5kV Airport Lighting Cable ..................................................6:6

RAILROAD AND TRANSIT SYSTEM CABLESArmored Signal Cable ....................................................................................................7:1

Track Wire .....................................................................................................................7:6

Tower and Case Wire ....................................................................................................7:10

Case Wire ......................................................................................................................7:11

Nylon Braid Case Wire ..................................................................................................7:12

Type DEL........................................................................................................................7:17

SPLICING AND TERMINATING PRODUCTSC-L-X Terminating Tool Kit ............................................................................................ 6:5

Color Code Tables ......................................................................................................... OSL

Miscellaneous Information ............................................................................................. OSL

OSC Index 10/2021

INDUSTRY ASSOCIATIONS

ABS American Bureau of Shipping.

AEIC Association of Edison

Illuminating Companies.

ANSI American National Standards

Institute.

AREMA American Railway Engineering

and Maintenance of Way Association

ASTM American Society for Testing and

Materials.

ICEA Insulated Cable Engineers

Association (formerly IPCEA).

IEC International Electrotechnical

Commission

IEEE Institute of Electrical and

Electronics Engineers.

NEC National Electrical Code.

NEMA National Electrical

Manufacturers Association.

NFPA National Fire Protection

Association.

GOVERNMENT AGENCIES

OSHA Occupational Safety and Health

Act administered by U.S. Dept. of

Labor which establishes employee safety

standards in all industrial and commercial

establishments.

RUS Rural Utility Systems of the U.S.

Department of Agriculture, formerly REA.

FAA Federal Aviation Administration

EPA Environmental Protection Agency

DOE Department of Energy

FERC Federal Energy Regulatory

Commission

OKONITE REGISTERED TRADE

NAMES

C-L-X® Continuous-Lightweight-Exterior.

Welded and corrugated, impervious

metallic sheathed cables.

LOXARMOR® An interlocked “S” shaped

armor cable covering, normally galvanized

steel or aluminum.

OKOBON® A moisture resistant cable

finish consisting of an aluminum/

copolymer tape fused to itself and to an

overall jacket.

OKOBUS® Fieldbus instrumentation

cable.

OKOCLEAR TP® (TPPO) Thermoplastic

Polyolefin low smoke/zero halogen jacket

compound.

OKOCLEAR TS® Thermosetting Polyolefin low

smoke/zero halogen jacket compound.

OKOGUARD® Okonite's exclusive ethylene-pro-

pylene rubber (EPR) based, thermosetting

insulation, with an optimum balance of electrical

and physical properties unequaled in other solid

dielectrics, used on power cables rated 600 V

and above. (50th Anniversary - 2017)

OKOLENE® Thermoplastic polyethylene or

polypropylene based insulation or jacket

compound.

OKONITE® Okonite's exclusive ethylene

propylene rubber (EPR) based, thermo-

setting insulation used up to 2000V.

OKONITE-FMR® Okonite’s exclusive flame and

moisture resistant ethylene propylene rubber

(EPR) insulation used up to 2000V.

OKOGUARD-OKOLON® Composite insulation

system consisting of a layer of EPR and covered

with a chlorinated thermoset compound.

OKOPACT® Okonite’s unique compact round

conductor shape and design.

OKOSEAL® A PVC insulation or jacketing

compound with excellent resistance to flame and

most chemicals.

OKOSEAL-N® PVC insulated and nylon

jacketed low voltage conductors, Type THHN,

THWN-2 and TFN.

OKOLON TP-CPE® Thermoplastic moisture

resistant CPE compound serving as an outer

jacket.

OKOLON TS-CPE® Thermoset moisture

resistant flame retardant CPE outer jacket.

OKOTEMP® - Thermoplastic rubber jacketing

compound with excellent abrasion resistance

combined with flexibility.

OKOTHERM® Heat resistant silicone rubber

based insulation for use in high temperature

locations.

OKOZEL® Okonite's name for its ETFE based

flame and radiation resistant

insulating and jacketing compound.

P-30® Okolene-Okoseal insulated 600V

multiple and single conductor control

cable.

P-45® Okolene-Okoseal Insulated 1000V

Multiple Conductor Control Cable.

X-OLENE® Okonite's name for its XLPE

insulation and jacket.

STANDARD TERMS

AWG American Wire Gauge, based on the

circular mil system where 1 mil equals 0.001

inch.

CIC Cable in Conduit for buried distribution

systems.

CIC Circuit Integrity flame retardant cables

C-L-X-M C-L-X Marine Shipboard Cable

CPE Chlorinated Polyethylene jacketing

material.

CSA Canadian Standards Association. An

independent organization which implements

and monitors the commercial and consumer

electrical product standards. The CSA

assures compliance to the various Canadian

Electrical Code requirements.

CT Designation given to cables meeting UL

requirements for cable tray use.

CTC Designation for Centralized Traffic

Control Code Line cable.

CWCMC UL’s designation for 600 volt

C-L-X marine shipboard cable - “continu-

ously welded corrugated MC” cable.

DEL Diesel Electric Locomotive and car

wiring with Okonite insulation and Okolon

jacket.

EPR Ethylene Propylene Rubber insulating

compound ingredient.

ER Exposed Run, UL term designating

cables approved for open wire applications.

ETFE Modified Ethylene Tetrofluoroethylene

compound (Okozel) used for insulation and

jackets.

FIELDBUS CABLE - High Speed digital

signal transmission instrumentation cable

having specific electrical characteristics.

FPL Power limited Fire Protective Signal

Cable (NEC Art. 760). 300V rated

FMR Flame and Moisture Retardant.

HL Designation given to MC and ITC cables

meeting NEC and UL requirements for use

in Division 1 hazardous locations.

INSULATION LEVEL-100% Cable for use

on grounded systems or where the system is

provided with relay protection such that

grounds faults will be cleared as rapidly as

possible but in any case within one minute.

INSULATION LEVEL-133% Cable for use

on ungrounded or grounded systems or

where the faulted section will be de-ener-

gized in a time not exceeding one hour.

ITC Instrumentation Tray Cable for

instrumentation & control circuits operating

�150V and �5 amps., per NEC Article 727.

GLOSSARY

5

kcmil A unit of conductor area in thou-

sands of circular mils. (Formerly MCM).

LOCA Loss of Coolant Accident, IEEE

383 defines test requirements.

LCS Longitudinal Corrugated Shield.

MC Metal-Clad cable. NEC type designa-

tion for power and control cables enclosed

in a welded and corrugated metallic

sheath (C-L-X), or an interlocking tape

armor (Loxarmor). (Article 330)

MC-HL Metal-Clad cable listed for

hazardous locations

mil 0.001 inch.

MV Medium Voltage cable. NEC designa-

tion for single & multiple conductor

insulated cable rated 2001 to 35,000 volts.

(NEC Article 328)

NPLF Non-Power Limited Fire Protective

Signal Cable (NEC Art. 760). 600V rated

OKO-MARINE UL designation for

non-armored Marine Shipboard Cable.

PLTC Type designation for Power-

Limited Tray Cable for use in Class 2 or 3

power-limited circuits; instrumentation,

supervisory control, and thermocouple

extension.

P-NS Single pair or triad, Non Shielded,

instrumentation or thermocouple extension

cable.

P-OS Single or multi Pairs or Triads with

Overall Shield, instrumentation or thermo-

couple extension cable.

POWER-LIMITED CIRCUIT Circuit either

inherently limited requiring no overcurrent

protection or limited by a combination of a

power source and overcurrent protection.

PVC Polyvinyl Chloride insulating and

jacketing material which is usually flame

retardant and resistant to many

chemicals.

P-104 Okonite’s identification number

issued by the Pennsylvania Department of

Environmental Resources.

RHH NEC conductor type designation for

conductors with Heat resistant rubber or

XLPE insulation, for use in dry locations.

RHW-2 NEC conductor type designation

for conductors with Heat and Moisture

resistant rubber or XLPE insulation, for

use in 90°C wet or dry locations.

RTA Thermoplastic insulated, aluminum

shielded, polyethylene jacketed communi-

cation cable.

SCREEN A semiconducting nonmetallic layer

used under and over the insulation of

power cables rated over 2kV to reduce

electrical stresses and corona

SEMICONDUCTING An extruded layer or tape

of such resistance that when applied between

two elements of a cable the adjacent surfaces of

the two elements will maintain substantially the

same potential.

SHIELD A nonmagnetic, metallic material

applied over an insulated conductor(s) to confine

the electric field to the insulation.

SP-OS Multiple Shielded Pairs or Triads with

Overall Shield, instrumentation or thermocouple

extension cable.

SR Sunlight Resistant

TC NEC type designation for power and

control tray cable. (Article 336)

TFN NEC conductor type designation for PVC

insulated nylon jacketed conductors in sizes #18

and 16 AWG for use in dry locations.

THERMOCOUPLE CABLE - A cable consisting

of two dissimilar metals or alloys that, when

electrically joined at one end can be used to

measure temperature. These cables have no

voltage rating.

THHN NEC conductor type designation for PVC

insulated nylon jacketed conductors for use in

dry locations.

THWN-2 NEC conductor type designation for

PVC insulated nylon jacketed conductors for use

in 90°C wet or dry locations.

TPPO Thermoplastic Polyolefin, a thermoplastic

jacket material with low smoke characteristics

and is free of halogens.

UL Underwriters Laboratories. An independent

organization which examines, tests, lists and

periodically inspects

equipment to appropriate standards.

URO-J Underground Residential distribution-

Okoguard (EPR) insulation-Okolene Jacket em-

ploying a concentric neutral.

USE Underground Service Entrance

cable. (NEC Article 338)

VERTICAL TRAY FLAME TEST

Conducted per UL, IEEE or ICEA procedures to

demonstrate that a single conductor (1/0 AWG

and larger) or multi-conductor cable will not

propagate a fire in the defined test.

VOLTAGE LEVELS

Power-Limited - 0-300 Volts

Low Voltage - 600-2000 Volts

Medium Voltage - 2400-46000 Volts

High Voltage - >46 to 345kV

VOLTAGE RATING V or kV, industry

convention to identify voltage levels, phase

to phase voltage.

VW-1 Basic flammability test for single

conductors; employs a tirrill burner applied

intermittently to a Vertical Wire.

XHHW-2 NEC conductor type designation

for conductors with Heat and Moisture resis-

tant thermoset insulation for use in 90°C wet

or dry locations.

XLPE Cross-Linked Polyethylene insulating

compound.

XLPO Cross Linked Polyolefin, a thermoset

jacket material with low smoke characteris-

tics and is free of halogens.

Z NEC conductor type designation for

conductors with ETFE insulation for use in

dry locations.

ZW NEC conductor type designation for

conductors with ETFE insulation for use in

wet or dry locations.

CONDUCTOR IDENTIFICATION

INFORMATION

E-1 Color sequences for utility conductor

identification, see Appendix E, Table E-1,

ICEA Standard S-73-532, includes green

and white.

E-2 Color sequence for industrial conductor

identification, see Appendix E, Table E-2,

ICEA Standard S-73-532, excludes green

and white.

METHOD-1 Conductor identification, colored

compounds with tracers in accordance with

the ICEA standard.

METHOD-2 Conductor identification, neutral

compounds with tracers in accordance with

the ICEA Standard.

METHOD-3 Conductor identification, neutral

or single colored compounds with surface

printing of numbers and color designations in

accordance with the ICEA Standard.

METHOD-4 Conductor identification, neutral

or single colored compounds with surface

printing of numbers in accordance with the

ICEA Standard.

METHOD-5 Conductor identification, individ-

ual color coding with braids in accordance

with the ICEA Standard.

GLOSSARY (continued)

6

Okoguard -Okolon TS-CPE Type MV-90® ®

2.4 kV Nonshielded Power CableOne Okopact (Compact Stranded)

®

Copper Conductor/90°C Rating Wet or DryFor Cable Tray Use-Sunlight Resistant

A Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen-ExtrudedBSemiconducting EPRInsulation-Okoguard EPRCJacket-Okolon TS-CPED

COMPACT STRAND

CONSTRUCTION Product DataSection 2: Sheet 2

InsulationOkoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequalled in other soliddielectrics. Okoguard insulation, with thedistinctive red color and a totally integratedEPR system, provides the optimum balancefor long, problem free service.

JacketThe Okolon TS-CPE jacket on this cable is avulcanized chloronated polyethylene basedcompound which is mechanically rugged,flame, radiation and oil resistant.

ApplicationsOkoguard-Okolon TS-CPE 2 .4 kV cables areheavy duty nonshielded cables designed foruse at up to 2.4 kV phase-to-phase in wet ordry locations in accordance with NEC.

Okoguard-Okolon TS-CPE nonshieldedcables are recommended for power distribu-tion and motor circuits in generating plantsand substations; in industrial and commercialbuildings.

Single conductors may be installed inindustrial or commercial occupancies intriplexed or random lay in any raceway or ductin wet or dry locations, or in open runs aspermitted by the NEC.

Sizes 1/0 AWG and larger, may be installed incable trays where permitted by NEC Section311.32(2).

SpecificationsConductor: Annealed uncoated coppercompact stranded per ASTM B-496.

Strand Screen: Extruded semiconductingEPR strand screen. Meets or exceedselectrical and physical requirements of ICEAS-96-659/NEMA WC71 and UL 1072.

Insulation: Meets or exceeds electrical andphysical requirements of ICEA S-96-659/NEMA WC71 and UL 1072.

Jacket: Meets or exceeds electrical andphysical requirements of ICEA S-96-659/NEMA WC71 for chlorinated polyethylenejackets.UL listed as Type MV-90, sunlight resistant, -40°C and for use in cable tray in accordance

with UL 1072. CSA listed as RW90 as 5kVnon-shielded (FT4 1/0 and larger) -40°C inaccordance with CSA C22.2 No 38.

1/C non-shielded cables can surfacedischarge in service when in a randomphase spacing or when in contact withgrounded surfaces.

Product Features• Okoguard cables meet or exceed allrecognized industry standards (UL, CSA,NEMA/ICEA, IEEE).

• 90°C continuous operating temperature.

• 130°C emergency rating.

• 250°C short circuit rating.

• Passes UL and IEEE 383 and 1202/FT4(1/0 and larger) Vertical Tray Flame Test.

• Sizes 500 kcmil and larger pass ICEA

T-29-520 (210,000 BTU/hr) Vertical TrayFlame Test.

• Sizes 1/0 and larger pass CSA FT4Vertical Tray Flame Test.

• Sizes #1 and smaller pass CSA FT1.

• Excellent corona resistance.

• Radiation resistant.

• Exceptional resistance to "treeing".

• Stress cones not required.

• Moisture resistant.

• Resistant to most oils, acids, and alkalies.

• Sunlight Resistant.

• Sizes #6 and #8 AWG are identified asFAA-L-824, Type B 5kV rated.

ULR

Okoguard-Okolon TS-CPE Type MV-902.4 kV Nonshielded Power CableOne Okopact (Compact Stranded)

°C Rating Wet or DryCopper Conductor/90For Cable Tray Use-Sunlight Resistant

Product DataSection 2: Sheet 2

*▲114-24-2213*▲114-24-2217▲114-24-2219▲114-24-2221

8 8.46 13.34 21.22 33.6

125 3.18125 3.18125 3.18125 3.18

80 2.0380 2.0380 2.0380 2.03

0.60 15.10.63 16.00.67 17.10.73 18.6

215 250260 295328 368427 492

55 64 -75 85 -97 110 -

130 145 -

2222

114-24-2223▲114-24-2225▲114-24-2227

114-24-2229

1 42.41/0 53.52/0 67.43/0 85.0

125 3.18125 3.18125 3.18125 3.18

80 2.0380 2.0380 2.0395 2.41

0.76 19.40.80 20.30.88 22.40.96 24.5

493 558580 645682 742838 908

155 170 -180 195 260205 220 300240 250 345

2½2½2½3

▲114-24-2231114-24-2233

▲114-24-2237

4/0 107.0250 127.0350 177.0

125 3.18140 3.56140 3.56

95 2.41110 2.79110 2.79

0.97 24.61.08 27.41.18 29.9

991 10861198 12931555 1660

280 290 400315 320 445385 385 550

333½

▲114-24-2243▲114-24-2249

114-24-2251

500 253.0750 380.0

1000 507.0

140 3.56155 3.94155 3.94

110 2.79125 3.18125 3.18

1.29 32.91.54 39.01.70 43.0

2075 22053034 32243891 4141

475 470 695600 585 900690 670 1075

3½55

Okonite’s web site, www.okonite.com contains the most up to date information.

▲ Available from our Customer Service Center.Authorized stock item.

Aluminum Okopact Conductors(1) Aluminum conductors are available on special order.Ampacities(2) Ampacities are in accordance with Table 311.60(C)(73) of the NEC for three singleType MV-90 conductors, or single conductors twisted together (triplexed) andinstalled in an isolated conduit in air at an ambient temperature of 40°C and aconductor temperature of 90°C.

(3) Ampacities are in accordance with Table 311.60(C)(77) of the NEC for three singleconductors or triplexed cable in one underground raceway, three feet deep witha conductor temperature of 90°C, 100% Load Factor, an ambient earth temperatureof 20°C, and thermal resistance (RHO) of 90.

(4) Ampacities for cable in cable tray are in accordance with the NEC, Section 392.80(B)(2)(2),Table 311.60(C)(69) (copper), for single conductor cables installed in a single layer, in uncoveredtray, with a maintained spacing of 1 cable OD or more at 90°C conductor temperature and 40°Cambient temperature and multi-point grounding.

O/21010202

THE OKONITE COMPANYRamsey, New Jersey 07446

Catalo

g Num

ber (1)

Conductor s

ize

AWG

or k

cmil

Conductor S

ize -m

Insula

tion

Thickness -

mils

Insula

tion

Thickness -

mm

Jacket Thic

kness - m

ils

Jacket Thic

kness - m

m

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

Approx. N

et Weig

ht

lbs./1

000’

Approx. S

hip W

eight

lbs./1

000’

Am

paciti

es (2

)

Conduit

inAir

Am

paciti

es (3

)

Under

ground D

uct

Conduit Siz

e

Inches

(5)*

* Marked “FAA L-824 5kV Type B”.

Am

paciti

es (4

)

Cab

le T

ray

Refer to the NEC, IEEE/ICEA-S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin for other ambient temperatures, circuit configurationsor installation requirements.

(5) Recommended size of rigid or nonmetallic conduit for three conductorsbased on 40% maximum fill.

* The jam ratio, conduit I.D. to cable O.D. should be checked to avoid possiblejamming.

ULR

Okoguard -Okoseal Type MV-105® ®

5/8kV Shielded Power CableOne Okopact (Compact Stranded) Copper Conductor/105°C Rating

®

5kV-133% or 8kV-100% Insulation LevelFor Cable Tray Use-Sunlight Resistant

A Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen-ExtrudedBSemiconducting EPRInsulation-Okoguard EPRCInsulation Screen-Extruded Semi-Dconducting EPRShielding-Copper TapeEJacket-OkosealF

COMPACT STRAND

CONSTRUCTION Product DataSection 2: Sheet 3

InsulationOkoguard is Okonite's registered tradename for its exclusive ethylene-propylenerubber (EPR) based, thermosettingcompound, whose optimum balance ofelectrical and physical properties isunequaled in other solid dielectrics.Okoguard insulation, with the distinctivered color and a totally integrated EPRsystem, provides the optimum balance ofelectrical and physical properties for long ,problem free service.

The triple tandem extrusion of the screenswith the insulation provides optimumelectrical characteristics.

JacketThe Okoseal (PVC) jacket supplied withthis cable is mechanically rugged and hasexcellent resistance to oil, acids and mostchemicals.

ApplicationsOkoguard shielded Okoseal Type MV-105power cables are recommended for useas feeder circuits, in electric utilitygenerating stations, for distributioncircuits, and for feeders or branch circuitsin industrial and commercial installations.

Type MV cables may be installed in wet ordry locations, indoors or outdoors(exposed to sunlight), in any raceway orunderground duct, directly buried ifinstalled in a system with a groundingconductor in close proximity that conformswith NEC Section 311.36 and 250.4(A)(5),or messenger supported in industrialestablishments and electric utilities. Sizes1/0 AWG and larger may also be installedin cable tray.

SpecificationsConductor: Annealed uncoated coppercompact stranded per ASTM B-496.

Strand Screen: Extruded semiconductingEPR strand screen. Meets or exceedselectrical and physical requirements ofICEA S-93-639/NEMA WC74 & S-97-682,AEIC CS8, CSA C68.10 and UL 1072.

Insulation: Meets or exceeds electricaland physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8,CSA C68.10 and UL 1072.

Insulation Screen: Extruded semiconductingEPR insulation screen applied directly overthe insulation. Meets or exceeds electricaland physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8,CSA C68.10 and UL 1072.

Shield: 5 mil bare copper tape helicallyapplied with 25% minimum overlap.

Jacket: Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, CSA C68.10and UL 1072 for polyvinyl chloride jackets.

UL listed as Type MV-105 and sunlightresistant, in accordance with UL 1072.

CSA C68.10 listed as FT4, SR, LTGG

(-40°C), TC (< 500 kcmil) and TC-ER (≥ 500kcmil).

Product Features•Triple tandem extruded, all EPRsystem.

• Okoguard cables meet or exceed allrecognized industry standards (UL, AEIC,NEMA/ICEA, IEEE).

• 105°C continuous operating temperature.

• 140°C emergency rating.

• 250°C short circuit rating.

• Passes UL and IEEE 383 and 1202

(1/0 AWG and larger) Vertical Tray FlameTest.

• Excellent corona resistance.

• Screens are clean stripping.

• Exceptional resistance to "treeing".

• Exceptional resistance to moisture.

• Resistant to most oils, acids, andalkalies.

• Sunlight resistant.

• For Cable Tray Use.

• Improved Temperature Rating.

ULR

Okoguard-Okoseal Type MV-1055/8kV Shielded Power CableOne Okopact (Compact Stranded)

105°C Rating WetCopper Conductor/5kV-133% or 8kV-100% Insulation LevelFor Cable Tray Use-Sunlight Resistant

Okoguard Insulation: 115 mils (2.92mm), 5kV-133% or 8kV-100% Insulation Level

Product DataSection 2: Sheet 3

▲114-23-3824▲114-23-3826

114-23-3865▲114-23-3832

1/0 53.52/0 67.43/0 85.04/0 107.0

0.61 0.670.65 0.710.70 0.760.75 0.81

60 1.5260 1.5280 2.0380 2.03

0.81 20.60.85 21.60.95 24.10.99 25.2

615 655720 775895 950

1030 1090

200 210 290225 235 335270 270 385305 310 445

2½2½33

▲114-23-3834▲114-23-3838▲114-23-3846▲114-23-3873

114-23-3855

250 127.0350 177.0500 253.0750 380.0

1000 507.0

0.80 0.860.89 0.951.01 1.071.19 1.261.34 1.40

80 2.0380 2.0380 2.0380 2.0380 2.03

1.05 26.71.14 29.01.26 32.01.45 36.91.59 40.4

1185 12501540 16252055 21552940 31203781 3960

355 345 495430 415 610530 505 765665 630 990770 720 1185

33½3½44

Okonite’s web site, www.okonite.com contains the most up to date information.

K/21010203

THE OKONITE COMPANYRamsey, New Jersey 07446

Catalo

gNum

ber (1)

Conduct

or si

ze

AW

G o

r kc

mil

Conducto

r Size

-mm

²

Appro

x. D

ia. o

ver

Insu

latio

n (in.)

Appro

x. D

ia. o

ver

Scree

n (in.)

Jacket Thic

kness- m

ils

Jacket Thic

kness- m

m

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

Appro

x. N

et W

eight

lbs.

/100

0’

Appro

x. S

hip W

eight

lbs.

/100

0’

Am

paciti

es C

onduit in

Air

(2)

Am

paciti

esUnder

ground

Duct

(3)

Conduit

Size

Inch

es(5

)*

Am

paciti

es C

able

Tra

y (4

)

▲ Available from our Customer Service Center.Authorized stock item.Aluminum Conductors(1) Aluminum conductors are available on special order.Ampacities(2) Ampacities are in accordance with Table 311.60(C)(73) of the NEC for three singleType MV-105 5kV conductors, or single conductors twisted together (triplexed) andinstalled in an isolated conduit in air at an ambient temperature of 40°C and aconductor temperature of 105°C. Refer to Table 311.60(C)(73) for 8kV ampacities.(3) Ampacities are in accordance with Table 311.60(C)(77) of the NEC for three single5kV conductors or triplexed cable in one underground raceway, three feet deep witha conductor temperature of 105°C, 100% Load Factor, an ambient earth temperatureof 20°C, and thermal resistance (RHO) of 90. Refer to Table 311.60(C)(77) for 8kV ampacities.

(4) Ampacities for cable in cable tray are in accordance with the NEC,Section 392.80(B)(2)(2), Table 311.60(C)(69) (copper),for single conductor cables installed in a single layer, in uncovered tray,with a maintained spacing of 1 cable OD or more at 105°C conductortemperature and 40°C ambient temperature and multi-point grounding.

Refer to NEC, IEEE/ICEA-S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin for installation in duct banks, multiple point groundedshields, other ambient temperatures, circuit configurations or installationrequirements.

(5) Recommended size of rigid or nonmetallic conduit for three conductorsbased on 40% maximum fill.

* The jam ratio, conduit I.D. to cable O.D. should be checked to avoid possiblejamming.

ULR

Okoguard -Okoseal Type MV-105® ®

5/8kV Shielded Power CableOne Okopact (Compact Stranded) Copper Conductor/105°C Rating

®

5kV-133% or 8kV-100% Insulation Level

A Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen-ExtrudedBSemiconducting EPRInsulation-Okoguard EPRCInsulation Screen-Extruded Semi-Dconducting EPRShielding-Copper TapeEJacket-OkosealF

COMPACT STRAND

CONSTRUCTION Product DataSection 2: Sheet 4

InsulationOkoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totallyintegrated EPR system, provides theoptimum balance of electrical and physicalproperties for long , problem free service.

The triple tandem extrusion of the screenswith the insulation provides optimumelectrical characteristics.

JacketThe Okoseal (PVC) jacket supplied with thiscable is mechanically rugged and hasexcellent resistance to oil, acids and mostchemicals.

ApplicationsOkoguard shielded Okoseal Type MV-105power cables are recommended fordistribution circuits, and for feeders or branchcircuits.

Type MV cables may be installed in wet ordry locations, indoors or outdoors (exposedto sunlight), in any raceway or undergroundduct, directly buried if installed in a systemwith a grounding conductor in close proximitythat conforms with NEC Section 311.36 and250.4(A)(5), or messenger supported inindustrial establishments and electric utilities.

SpecificationsConductor: Annealed uncoated coppercompact stranded per ASTM B-496.

Strand Screen: Extruded semiconductingEPR strand screen. Meets or exceedselectrical and physical requirements of ICEAS-93-639/NEMA WC74 & S-97-682, AEICCS8, CSA C68.10 and UL 1072.

Insulation: Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8,CSA C68.10 and UL 1072.

Insulation Screen: Extruded semiconductingEPR insulation screen applied directly overthe insulation. Meets or exceeds electricaland physical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8,CSA C68.10 and UL 1072.

Shield: 5 mil bare copper tape helicallyapplied with 12.5% nominal overlap.

Jacket: Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, CSAC68.10 and UL 1072 for polyvinyl chloridejackets.

UL Listed as Type MV-105 and sunlightresistant, in accordance with UL 1072.

CSA C68.10 listed as FT1, SR, and

LTDD (-25°C).

Product Features• Triple tandem extruded, all EPR system.

• Okoguard cables meet or exceed allrecognized industry standards (UL, AEIC,NEMA/ICEA, IEEE).

• 105°C continuous operating temperature.

• 140°C emergency rating.

• 250°C short circuit rating.

• Excellent corona resistance.

• Screens are clean stripping.

• Exceptional resistance to "treeing".

• Exceptional resistance to moisture.

• Resistant to most oils, acids, and alkalies.

• Sunlight resistant.

• Improved Temperature Rating.

ULR

Okoguard-Okoseal Type MV-1055/8kV Shielded Power CableOne Okopact (Compact Stranded)

105°C RatingCopper Conductor/5kV-133% or 8kV-100% Insulation Level

Product DataSection 2: Sheet 4

▲114-23-3817▲114-23-3819▲114-23-3821

6 13.34 21.22 33.6

0.44 0.500.48 0.540.54 0.60

60 1.5260 1.5260 1.52

0.64 16.30.69 17.50.74 18.8

285 320355 385455 495

84 92110 120145 155

222

114-23-3823114-23-3825114-23-3827114-23-3829

1 42.41/0 53.52/0 67.43/0 85.0

0.58 0.630.61 0.670.65 0.710.70 0.75

60 1.5260 1.5260 1.5280 2.03

0.77 19.50.81 20.60.85 12.60.93 23.6

530 570610 645710 765880 935

175 180200 210225 235270 270

2½2½2½3

114-23-3831114-23-3833114-23-3837

4/0 107.0250 127.0350 177.0

0.75 0.810.80 0.860.89 0.95

80 2.0380 2.0380 2.03

0.99 25.11.04 26.41.14 29.0

1035 11001180 12451535 1625

305 310355 345430 415

333½

114-23-3843114-23-3849114-23-3851

500 253.0750 380.0

1000 507.0

1.01 1.071.19 1.251.33 1.39

80 2.0380 2.0380 2.03

1.25 31.81.43 36.81.57 39.9

2050 21502935 31103650 3825

530 505665 630770 720

3½45

Minimum Manufacturing Quantity for non-stock items is 5000’.Aluminum Conductors(1) Aluminum conductors are available on special order.Ampacities(2) Ampacities are in accordance with Table 311.60(C)(73) of the NEC for three singleType MV-105 5kV conductors or single conductors twisted together (triplexed) andinstalled in an isolated conduit in air at an ambient temperature of 40°C and aconductor temperature of 105°C. Refer to Table 311.60(C)(73) for 8kV ampacities.(3) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for three single5kV conductors or triplexed cable in one underground raceway, three feet deep witha conductor temperature of 105°C, 100% Load Factor, an ambient earth temperatureof 20°C, and thermal resistance (RHO) of 90. Refer to Table 311.60(C)(77) for 8kVampacities.

Q/21060204

THE OKONITE COMPANYRamsey, New Jersey 07446

Cata

log

Num

ber (1)

Conducto

r size

AWG

or kcmil

Conducto

r Size

-mm

²

Appro

x. Dia

over

Insula

tion

(in.)

Appro

x. Dia

. Over

Screen

(in.)

Jacket Thickness

- mils

Jacket Thickness

- mm

Appro

x. O.D

. -In

ches

Appro

x. O.D

. -m

m

Appro

x. Net W

eight

lbs./1

000’

Appro

x. Ship

Weig

ht

lbs./1

000’

Am

pacities

Conduit

inAir

(2)

Am

pacities

Underg

round

Duct (3

)

Conduit

Size

Inches

(4)*

Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin for installation in duct banks, multiple point groundedshields, other ambient temperatures, circuit configurations or installationrequirements.(4) Recommended size of rigid or nonmetallic conduit for three conductors basedon 40% maximum fill.*The jam ratio, conduit I.D. to cable O.D. should be checked to avoid possiblejamming.

Okoguard Insulation: 115 mils (2.92mm), 5kV-133% or 8kV -100% Insulation

Okonite’s web site, www.okonite.com contains the most up to date information.

ULR

▲ Available from our Customer Service Centers.Authorized stock item.

Okoguard -Okoseal Type MV-105® ®

15kV Shielded Power CableOne Okopact (Compact Stranded) Copper Conductor/105°C Rating

®

100% and 133% Insulation LevelFor Cable Tray Use-Sunlight Resistant

A Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen-ExtrudedBSemiconducting EPRInsulation-Okoguard EPRCInsulation Screen-ExtrudedDSemiconducting EPRShield-Copper TapeEJacket-OkosealF

COMPACT STRAND

CONSTRUCTION Product DataSection 2: Sheet 8

InsulationOkoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totallyintegrated EPR system, provides theoptimum balance of electrical and physicalproperties for long, problem free service.The triple tandem extrusion of the screenswith the insulation provides optimumelectrical characteristics.

JacketThe Okoseal (PVC) jacket supplied with thiscable is mechanically rugged and hasexcellent resistance to flame, oil, acids andmost chemicals.

ApplicationsOkoguard shielded Okoseal Type MV-105power cables are recommended for use asfeeder circuits, in electric utility generatingstations, for distribution circuits, and forfeeders or branch circuits in industrial andcommercial installations.Type MV cables may be installed in wet ordry locations, indoors or outdoors (exposedto sunlight), in any raceway or undergroundduct, directly buried if installed in a systemwith a grounding conductor in close proximitythat conforms with NEC Section 311.36 and250.4(A)(5), or messenger supported inindustrial establishments and electric utilities.Sizes 1/0 AWG and larger may also beinstalled in cable tray as permitted by NECSection 311.32(2).

SpecificationsConductor: Annealed uncoated coppercompact stranded per ASTM B-496.Strand Screen: Extruded EPRsemiconducting strand screen. Meets orexceeds electrical and physical requirementsof ICEA S-93-639/NEMA WC74 & S-97-682,AEIC CS8, CSA C68.10 and UL 1072.Insulation: Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8,CSA C68.10 and UL 1072.Insulation Screen: Extruded EPRsemiconducting insulation screen applieddirectly over the insulation. Meets or exceedselectrical and physical requirements of ICEA

S-93-639/NEMA WC74 & S-97-682,AEIC CS8, CSA C68.10 and UL 1072.Shield: 5 mil bare copper tape helicallyapplied with 25% minimum overlap.Jacket: Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, CSA C68.10and UL 1072 for polyvinyl chloride jackets.

UL listed as Type MV-105, sunlightresistant, and for use in cable tray inaccordance with UL 1072.

CSA C68.10 listed as FT4, SR, LTGG(-40°C), TC (< 500 kcmil) and TC-ER (≥ 500kcmil).

Product Features• Triple tandem extruded, all EPR system.

• Okoguard cables meet or exceed allrecognized industry standards (UL, CSA,AEIC, NEMA/ICEA, IEEE).• 105°C continuous operating temperature.• 140°C emergency rating.• 250°C short circuit rating.• Passes the Vertical Tray Flame Testrequirements of UL 1072 and IEEE 383 and1202.• Excellent corona resistance.• Screens are clean stripping.• Exceptional resistance to "treeing".• Exceptional resistance to moisture.• Resistant to most oils, acids, and alkalies.• Sunlight resistant.• For Cable Tray Use.• Improved Temperature Rating.

ULR

Okoguard-Okoseal Type MV-10515kV Shielded Power CableOne Okopact (Compact Stranded)

105°C RatingCopper Conductor/100% and 133% Insulation LevelFor Cable Tray Use - Sunlight Resistant

Product DataSection 2: Sheet 8

115-23-3064115-23-3066115-23-3067

1/0 53.52/0 67.43/0 85.0

0.74 0.800.78 0.840.83 0.89

80 2.0380 2.0380 2.03

0.98 24.81.02 25.81.07 27.1

760 825870 935

1005 1070

215 215 290255 245 335290 275 385

333

115-23-3069115-23-3074115-23-3076

4/0 107.0250 127.0350 177.0

0.88 0.940.93 0.981.03 1.07

80 2.0380 2.0380 2.03

1.12 28.41.17 29.71.26 32.0

1160 12401330 14151700 1800

330 315 445365 345 495440 415 610

33½3½

115-23-3090115-23-3091115-23-3092

500 253.0750 380.0

1000 507.0

1.14 1.191.32 1.371.47 1.52

80 2.0380 2.0380 2.03

1.38 35.11.55 39.41.71 43.4

2230 22753105 33403960 4215

535 500 765655 610 990755 690 1185

455

Okoguard Insulation: 220 mils (5.59mm), 133% Insulation Level

U/21050208 THE OKONITE COMPANYRamsey, New Jersey 07446

Catalo

gNum

ber (1)

Conduct

or si

ze

AW

G o

r kc

mil

Conduct

or Size

-mm

²

Appro

x. D

ia. o

ver

Insu

latio

n (in.)

Appro

x. D

ia. o

ver

Scree

n (in.)

Jacket Thic

kness- m

ils

Jacket Thic

kness- m

m

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

Appro

x. N

et W

eight

lbs.

/100

0’

Appro

x. S

hip W

eight

lbs.

/100

0’

Am

paciti

es (2

) Conduit

inAir

Am

paciti

es(3

) Under

ground

Duct

Conduit

Size

Inch

es(5

)*

Am

paciti

es (4

) Cab

le T

ray

▲115-23-3479**▲115-23-3230▲115-23-3232

115-23-3234

2 33.61/0 53.52/0 67.43/0 85.0

0.76 0.810.83 0.880.87 0.920.92 0.98

80 2.0380 2.0380 2.0380 2.03

0.99 25.21.10 28.01.11 28.21.16 29.4

682 742905 975970 1030

1170 1185

165 165 ̶215 215 290255 245 335290 275 385

3333½

▲115-23-3236▲115-23-3238▲115-23-3240

4/0 107.0250 127.0350 177.0

0.96 1.021.01 1.071.11 1.17

80 2.0380 2.0380 2.03

1.21 30.71.26 32.01.35 34.3

1280 13701435 15201810 1940

330 315 445365 345 495440 415 610

3½3½4

▲115-23-3242▲115-23-3243▲115-23-3244

500 253.0750 380.0

1000 507.0

1.22 1.281.40 1.461.55 1.60

80 2.0380 2.03

110 2.79

1.47 37.31.65 41.91.86 47.1

2350 25353240 34804220 4490

535 500 765655 610 990755 690 1185

456

Okoguard Insulation: 175 mils (4.45mm), 100% Insulation Level

▲ Available from our Customer Service Centers.Authorized Stock Item.Minimum Manufacturing Quantity for non-stock items is 5000’.Aluminum Conductors(1) Aluminum conductors are available on special order. To order aluminumconductors, change the first three digits of the catalog number from 115 to 135.Ampacities(2) Ampacities are in accordance with Table 311.60(C)(73) of the NEC for three singleType MV-105 conductors, or single conductors twisted together (triplexed) andinstalled in an isolated conduit in air at an ambient temperature of 40°C and aconductor temperature of 105°C.(3) Ampacities are in accordance with Table 311.60(C)(77) of the NEC for three singleconductors or triplexed cable in one underground raceway, three feet deep witha conductor temperature of 105°C, 100% Load Factor, an ambient earth temperatureof 20°C, and thermal resistance (RHO) of 90.Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacities, or the Okonite EngineeringData Bulletin EHB for installation in duct banks, multiple point ground shields, otherambient temperatures, circuit configurations or installation requirements.

(5) Recommended size of rigid or nonmetallic conduit for three conductorsbased on 40% maximum fill.* The jam ratio, conduit I.D. to cable O.D. should be checked to avoid possiblejamming.

**This cable is not recognized by UL for Cable Tray-Use

(4) Ampacities for cable in cable tray are in accordance with the NEC,Section 392.80(B)(2)(2), Table 311.60(C)(69) (copper), for single conductorcables installed in a single layer, in uncovered tray, with a maintained spacingof 1 cable OD or more at 105°C conductor temperature and 40°C ambienttemperature and multi-point grounding.

Okonite’s web site, www.okonite.com contains the most up to date information.

ULR

Okoguard -Okoseal Type MV-105® ®

15kV Shielded Power CableOne Okopact (Compact Stranded) Copper Conductor/105°C Rating

®

100% and 133% Insulation Level

A Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen-ExtrudedBSemiconducting EPRInsulation-Okoguard EPRCInsulation Screen-ExtrudedDSemiconducting EPRShield-Copper TapeEJacket OkosealF

COMPACT STRAND

CONSTRUCTION Product DataSection 2: Sheet 9

InsulationOkoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totallyintegrated EPR system, provides theoptimum balance of electrical and physicalproperties for long, problem free service.The triple tandem extrusion of the screenswith the insulation provides optimumelectrical characteristics.

JacketThe Okoseal (PVC) jacket supplied with thiscable is mechanically rugged and hasexcellent resistance to oil, acids and mostchemicals.

ApplicationsOkoguard shielded Okoseal Type MV-105power cables are recommended fordistribution circuits, and for feeders orbranch circuits.Type MV cables may be installed in wet ordry locations, indoors or outdoors (exposedto sunlight), in any raceway or undergroundduct, directly buried if installed in a systemwith a grounding conductor in close proximitythat conforms with NEC Section 311.36 and250.4(A)(5), or messenger supported inindustrial establishments and electric utilities.

SpecificationsConductor: Annealed uncoated coppercompact stranded per ASTM B-496.Strand Screen: Extruded semiconductingEPR strand screen. Meets or exceedselectrical and physical requirements of ICEAS-93-639/NEMA WC74, AEIC CS8, CSAC68.10 and UL 1072.Insulation: Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8,CSA C68.10 and UL 1072.Insulation Screen: Extrudedsemiconducting EPR insulation screen .Meets or exceeds electrical and physicalrequirements of ICEA S-93-639/NEMAWC74 & S-97-682, AEIC CS8, CSA C68.10and UL 1072.Shield: 5 mil bare copper tape helicallyapplied with 12.5% nominal overlap.

Jacket: Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, CSAC68.10 and UL 1072 for polyvinyl chloridejackets.UL Listed as Type MV-105 and sunlightresistant in accordance with UL 1072 .CSA C68.10 listed as FT1, SR, andLTDD (-25°C).

Product Features• Triple tandem extruded, all EPR system.• Okoguard cables meet or exceed allrecognized industry standards (UL, AEIC,NEMA/ICEA, IEEE).• 105°C continuous operatingtemperature.• 140°C emergency rating.• 250°C short circuit rating.• Excellent corona resistance.• Screens are clean stripping.• Exceptional resistance to "treeing".• Moisture resistant.• Resistant to most oils, acids, andalkalies.• Sunlight resistant.• Improved Temperature Rating.

ULR

Okoguard-Okoseal Type MV-10515kV Shielded Power CableOne Okopact (Compact Stranded)

105°C RatingCopper Conductor/

Product DataSection 2: Sheet 9

115-23-3011115-23-3013

2 33.61 42.4

0.67 0.730.70 0.76

60 1.5280 2.03

0.87 22.10.94 23.9

555 610665 720

165 225 165190 260 185

33

115-23-3015115-23-3017115-23-3019

1/0 53.52/0 67.43/0 85.0

0.74 0.800.78 0.840.83 0.89

80 2.0380 2.0380 2.03

0.98 24.81.02 25.81.07 27.2

755 820865 930

1000 1070

215 295 215255 335 245290 380 275

333

115-23-3021115-23-3023115-23-3027

4/0 107.0250 127.0350 177.0

0.88 0.940.93 0.991.03 1.07

80 2.0380 2.0380 2.03

1.12 28.31.18 30.01.26 32.0

1170 12501325 14051700 1800

330 435 315365 475 345440 575 415

33½3½

115-23-3031115-23-3035115-23-3037

500 253.0750 380.0

1000 507.0

1.14 1.191.32 1.371.47 1.52

80 2.0380 2.0380 2.03

1.38 35.11.55 39.41.71 43.4

2240 23853105 33403950 4185

535 700 500655 865 610755 1005 690

455

Okoguard Insulation: 220 mils (5.59mm), 133% Insulation Level

O/21050209

THE OKONITE COMPANYRamsey, New Jersey 07446

Catalo

gNum

ber (1)

Conduct

or si

ze

AW

G o

r kc

mil

Conduct

or Size

-mm

²

Appro

x. D

ia. o

ver

Insu

latio

n (in.)

Appro

x. D

ia. o

ver

Scree

n (in.)

Jacket Thic

kness- m

ils

Jacket Thic

kness- m

m

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

Appro

x. N

et W

eight

lbs.

/100

0’

Appro

x. S

hip W

eight

lbs.

/100

0’

Am

paciti

es (2

) Conduit

inAir

Am

paciti

es(3

) Dire

ct B

urial

Conduit

Size

Inch

es(5

)*

Am

paciti

es (4

) Under

ground D

uct

115-23-3111115-23-3113

2 33.61 42.4

0.76 0.810.79 0.85

80 2.0380 2.03

1.00 25.41.04 26.4

670 720755 820

165 225 165190 260 185

33

115-23-3115115-23-3117115-23-3119

1/0 53.52/0 67.43/0 85.0

0.83 0.890.87 0.920.92 0.98

80 2.0380 2.0380 2.03

1.07 27.11.11 28.21.16 29.3

845 915950 1020

1000 1180

215 295 215255 335 245290 380 275

333½

115-23-3121115-23-3123115-23-3127

4/0 107.0250 127.0350 177.0

0.96 1.021.01 1.071.11 1.16

80 2.0380 2.0380 2.03

1.20 30.51.26 32.01.35 34.3

1260 13601415 15001790 1920

330 435 315365 475 345440 575 415

3½3½4

115-23-3131115-23-3135115-23-3139

500 253.0750 380.0

1000 507.0

1.22 1.281.40 1.461.54 1.60

80 2.0380 2.03

110 2.79

1.47 37.31.64 41.71.84 46.7

2325 25103220 34554075 4340

535 700 500655 865 610755 1005 690

456

Okoguard Insulation: 175 mils (4.45mm), 100% Insulation Level

Aluminum Conductors(1) Aluminum conductors are available on special order.Ampacities(2) Ampacities are in accordance with Table 311.60(C)(73) of the NEC for three singleType MV-105 conductors, or single conductors twisted together (triplexed) andinstalled in an isolated conduit in air at an ambient temperature of 40°C and aconductor temperature of 105°C.(3) Ampacities are in accordance with Table 311.60(C)(81) of the NEC for an insulatedsingle conductor directly buried with a conductor temperature rating of 105°C, ambientearth temperature of 20°C, 100% Load Factor, thermal resistance (RHO) of 90, 7 1/2 inchspacing between conductor center lines, and 24 inch spacing between circuits.

Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin for installation in duct banks, multiple point groundedshields, other ambient temperatures, circuit configurations or installationrequirements.(5) Recommended size of rigid or nonmetallic conduit for three conductorsbased on 40% maximum fill.* The jam ratio, conduit I.D. to cable O.D. should be checked to avoid possiblejamming.

(4) Ampacities are in accordance with Table 311.60(C)(77) of the NEC for three singleconductors or triplexed cable in one underground raceway, three feet deep with aconductor temperature of 105°C, 100% Load Factor, an ambient earth temperature of20°C, and thermal resistance (RHO) of 90.

Okonite’s web site, www.okonite.com contains the most up to date information.

ULR

Okoguard -Okolon TS-CPE Type MV-105® ®

15kV Shielded Power CableOne Okopact (Compact Stranded) Copper Conductor/105°C Rating

®

100% and 133% Insulation Level

For Cable Tray Use-Sunlight Resistant

A Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen-ExtrudedBSemiconducting EPRInsulation-Okoguard EPRCInsulation Screen-ExtrudedDSemiconducting EPRShield Copper TapeEJacket-Okolon TS-CPEF

COMPACT STRAND

CONSTRUCTION Product DataSection 2: Sheet 11

A

B

C

D

E

F

OK

ON

ITE

4 4

/0A

WG

CO

MP

AC

TC

U O

KO

GU

AR

DE

PT

S-C

PE

15kV

InsulationOkoguard is Okonite's registered trade namefor its exclusive ethylene-propylene (EPR)based, thermosetting compound, whoseoptimum balance of electrical and physicalproperties is unequaled in other soliddielectrics. Okoguard insulation, with thedistinctive red color and a totally integratedEPR system, provides the optimum balanceof electrical and physical properties for long,problem free service.The triple tandem extrusion of the screenswith the insulation provides optimum electricalcharacteristics.

JacketThe Okolon TS-CPE jacket on this cable is avulcanized chloronated polyethylene basecompound which is mechanically rugged,flame, radiation, and oil resistant.

ApplicationsOkoguard shielded Okolon TS-CPE Type MV-105 power cables are recommended for useas feeder circuits in electric utility generatingstations, for distribution circuits, and forfeeders or branch circuits in industrial andcommercial installations. Type MV cablesmay be installed in wet or dry locations,indoors or outdoors (exposed to sunlight), inany raceway or underground duct, directlyburied if installed in a system with agrounding conductor in close proximity thatconforms with NEC Section 311.36 and250.4(A)(5), or messenger supported inindustrial establishments and electric utilities.Sizes 1/0 AWG and larger may also beinstalled in cable tray.

SpecificationsConductor: Annealed uncoated coppercompact stranded per ASTM B-496.Strand Screen: Extruded semiconductingEPR strand screen. Meets or exceedselectrical and physical requirements of ICEAS-93-639/NEMA WC74 & S-97-682, AEICCS8, CSA C68.10 and UL 1072.Insulation: Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8,CSA C68.10 and UL 1072.Insulation Screen: Extruded semiconductingEPR insulation screen. Meets or exceeds

electrical and physical requirements of ICEAS-93-639/NEMA WC74 & S-97-682, AEICCS8, CSA C68.10 and UL 1072.Shield: 5 mil bare copper tape helicallyapplied, with 25% minimum overlap.Jacket: Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74 & S-97-682, CSA CS68.10and UL 1072 for chloronated polyethylenejackets.UL listed as Type MV-105, sunlight resistantand for use in cable tray in accordance withUL 1072.CSA C68.10 listed as FT4, SR, LTDD(-25°C), and TC (1/0 AWG & larger).

Product Features• Triple tandem extruded, all EPR system.

• Okoguard cables meet or exceed allrecognized industry standards (UL, AEIC,NEMA/ICEA, IEEE).

• 105°C continuous operating temperature.

• 140°C emergency rating.

• 250°C short circuit rating.

• Passes UL and IEEE 383 and 1202 (1/0AWG & larger) Vertical Tray Flame Tests.

• Excellent corona resistance.

• Screens are clean stripping.

• Exceptional resistance to “treeing."

• Moisture resistant.

• Resistant to most oils, acids, andalkalies.• Sunlight resistant.• UL listed For Cable Tray Use; 1/0 AWG &larger.• Improved Temperature Rating.

ULR

Okoguard-Okolon TS-CPE Type MV-10515kV Shielded Power CableOne Okopact (Compact Stranded)Copper Conductor/ 105°C Rating100% and 133% Insulation LevelFor Cable Tray Use-Sunlight Resistant

Okoguard Insulation: 175 mils (4.45mm), 100% Insulation Level

115-23-2011115-23-2013

21

33.642.4

0.670.70

0.730.76

6080

1.522.03

0.890.96

22.524.4

585700

640765

165190

165185

——

33

115-23-2015115-23-2017115-23-2019

1/02/03/0

53.567.485.0

0.730.770.82

0.790.830.88

808080

2.032.032.03

1.001.041.09

25.326.427.6

790905

1040

855965

1110

215255290

215245275

290335385

333

115-23-2021115-23-2023115-23-2027

4/0250350

107.0127.0177.0

0.870.931.01

0.930.991.07

808080

2.032.032.03

1.131.191.28

28.730.332.4

120013701725

128014501825

330365440

315345415

445495610

312

312

4

115-23-2031115-23-2035115-23-2038

500750

1000

253.0380.0507.0

1.131.311.46

1.191.371.52

808080

2.032.032.03

1.391.571.73

35.439.943.9

225531404020

237033204255

535655755

500610690

765990

1185

455

Okoguard Insulation: 220 mils (5.59mm), 133% Insulation Level

115-23-2111115-23-2113

21

33.642.4

0.750.79

0.810.85

8080

2.032.03

1.011.05

25.826.7

710790

775860

165190

165185

——

33

115-23-2115115-23-2117115-23-2119

1/02/03/0

53.567.485.0

0.820.860.91

0.880.920.97

808080

2.032.032.03

1.081.121.18

27.528.529.9

880995

1145

94510751225

215255290

215245275

290335385

312

312

312

115-23-2121115-23-2123115-23-2127

4/0250350

107.0127.0177.0

0.961.011.10

1.021.071.16

808080

2.032.032.03

1.221.281.37

31.132.434.7

131014651840

140015651940

330365440

315345415

445495610

312

44

� 115-23-2131� 115-23-2135

115-23-2138

500750

1000

253.0380.0507.0

1.221.401.54

1.281.461.60

8080

110

2.032.032.79

1.491.661.87

37.742.247.5

238532854275

257035404540

535655755

500610690

765990

1185

556

115-23-2144115-23-2145

12501500

633.5760.2

1.751.88

1.811.94

110110

4.334.33

2.082.20

52.756.0

52556140

56456540

845925

770845

13501500

68

Okonite's web site, www.okonite.com contains the most up to date information.

� Authorized Stock Item. Available from our Customer Service Centers.

Aluminum Conductors

(1) Aluminum conductors are available on special order.

Ampacities

(2) Ampacities are in accordance with Table 311.60(C)(73) of the NEC for threesingle Type MV-105 conductors, or single conductors twisted together (tri-plexed) and installed in an isolated conduit in air at an ambient temperature of40°C and a conductor temperature of 105°C.

(3) Ampacities are in accordance with Table 311.60(C)(77) of the NEC for threesingle conductors or triplexed cable in one underground raceway, three feetdeep with a conductor temperature of 105°C, 100% Load Factor, an ambientearth temperature of 20°C and thermal resistance (RHO) of 90.

(4) Ampacities for cable in cable tray are in accordance witht he NEC, Section392.80(B)(2)(2), Table 311.60(C)(69) (copper), for single conductor cables in-stalled in a single layer, in uncovered tray, with a maintained spacing of 1 cable

OD or more at 105°C conductor temperature and 40°C ambient temperatureand multi-point grounding.

Refer to the NEC, IEEE/ICEA-S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin for installation in duct banks, multiple point groundedshields, other ambient temperatures, circuit configurations or installation re-quirements.

(5) Recommended size of rigid or nonmetallic conduit for three conductorsbased on 40% maximum fill.

*The jam ratio conduit l.D. to cable O.D. should be checked to avoid possiblejamming.

P/21010211

Product DataSection 2: Sheet 11

Catalo

gNum

ber(1

)

Approx.

NetW

eight

(lbs./

1000

’)

Conductor Size

- mm

2

Approx.

O.D. -

mm

Conductor Size

AWG

or kcm

il

Jack

et

Thicknes

s - mm

Approx.

Dia.

over In

sulat

ion

(in.)

Jack

et

Thicknes

s - mils

Approx.

O.D. -

Inch

es

Approx.

Dia.

over Scr

een

(in.)

Approx.

ShipW

eight

(lbs./

1000

’)

Ampac

ities

(3)

Undergro

und

Conduit(5

)

SizeIn

ches

*

Ampac

ities

(2)

Conduitin

Air

Ampac

ities

(4)

Cable

Tray

THE OKONITE COMPANYRamsey, New Jersey 07446

ULR

Okoguard -Okoseal Type MV-105® ®

35kV Shielded Power CableOne Okopact (Compact Stranded) Copper Conductor/105°C Rating

®

100% and 133% Insulation Level

A Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen-ExtrudedBSemiconducting EPRInsulation-Okoguard EPRCInsulation Screen-ExtrudedDSemiconducting EPRShield-Copper TapeEJacket-OkosealF

COMPACT STRAND

CONSTRUCTION Product DataSection 2: Sheet 16

InsulationOkoguard Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totallyintegrated EPR system, provides theoptimum balance of electrical and physicalproperties for long, problem free service. Thetriple tandem extrusion of the screens withthe insulation provides optimum electricalcharacteristics.

JacketThe Okoseal (PVC) jacket supplied with thiscable is mechanically rugged and hasexcellent resistance to oil and mostchemicals.

ApplicationsOkoguard shielded Okoseal Type MV-105power cables are recommended fordistribution circuits, and for feeders orbranch circuits in industrial and commercialinstallations.Type MV cables may be installed in wet ordry locations, indoors or outdoors (exposedto sunlight), in any raceway or undergroundduct, directly buried if installed in a systemwith a grounding conductor in close proximitythat conforms with NEC Section 311.36 and250.4(A)(5), or messenger supported inindustrial establishments and electric utilities.

SpecificationsConductor: Annealed uncoated coppercompact stranded per ASTM B-496.Strand Screen: Extruded semiconductingEPR strand screen. Meets or exceedselectrical and physical requirements of ICEAS-93-639/NEMA WC7 & S-97-682, AEICCS8, CSA C68.10 and UL 1072.Insulation: Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74, & S-97-682 AEIC CS8,CSA C68.10 and UL 1072.Insulation Screen: Extrudedsemiconducting EPR insulation screen.Meets or exceeds electrical and physicalrequirements of ICEA S-93-639/NEMAWC74 & S-97-682, AEIC CS8, CSA C68.10and UL 1072.Shield: 5 mil bare copper tape helicallyapplied with 12.5% nominal overlap.

Jacket: Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMAWC74 & S-97-682, CSA C68.10 and UL 1072for polyvinyl chloride jackets.

UL Listed as Type MV-105 and sunlightresistant, in accordance with UL 1072.

CSA C68.10 listed as FT1, SR, and LTDD(-25°C).

Product Features• Triple tandem extruded all EPR system.

• Okoguard cables meet or exceed allrecognized industry standards (UL, AEIC,NEMA/ICEA, IEEE).

• 105°C continuous operating temperature.

• 140°C emergency rating.

• 250°C short circuit rating.

• Excellent corona resistance.

• Screens are clean stripping.

• Exceptional resistance to "treeing."

• Moisture resistant.

• Resistant to most oils, acids, and alkalies.

• Sunlight resistant.

• Improved Temperature Rating.

UL®

Okoguard-Okoseal Type MV-10535kV Shielded Power CableOne Okopact (Compact Stranded)Copper Conductor/105°C Rating100% and 133% Insulation Level

Product DataSection 2: Sheet 16

115-23-3516115-23-3517115-23-3519

1/0 53.52/0 67.43/0 85.0

1.09 1.151.12 1.191.17 1.23

80 2.0380 2.0380 2.03

1.33 34.01.37 35.01.42 36.1

1140 12751270 13801420 1605

215 295 215255 335 245290 380 275

444

115-23-3521115-23-3523115-23-3527

4/0 107.0250 127.0350 177.0

1.23 1.291.27 1.331.36 1.43

80 2.0380 2.0380 2.03

1.47 37.41.52 38.71.61 41.2

1595 18001790 19502150 2420

330 435 315365 475 345440 575 415

455

115-23-3531115-23-3535115-23-3537

500 253.0750 380.0

1000 507.0

1.48 1.541.66 1.721.81 1.86

80 2.03110 2.79110 2.79

1.73 43.91.97 50.12.12 53.9

2720 30143765 42404671 5300

535 700 500655 865 610755 1005 690

566

Okoguard Insulation: 420 mils (10.7mm), 133% Insulation Level

S/21050216

THE OKONITE COMPANYRamsey, New Jersey 07446

Catalo

g Num

ber (1)

Conductor s

ize

AWG

or k

cmil

Conductor S

ize -m

Approx. D

ia. o

ver

Insula

tion (i

n.)

Approx. D

ia. o

ver

Screen (i

n.)

Jacket Thic

kness - m

ils

Jacket Thic

kness - m

m

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

Approx. N

et Weig

ht

lbs./1

000’

Approx. S

hip W

eight

lbs./1

000’

Ampaciti

es (2) C

onduit in

Air

Ampaciti

es (3) D

irect B

urial

Conduit Siz

e

Inches (5

)*

Ampaciti

es (4) U

ndergro

und Duct

115-23-3656115-23-3657115-23-3659

1/0 53.52/0 67.43/0 85.0

1.24 1.301.28 1.341.32 1.39

80 2.0380 2.0380 2.03

1.49 37.91.53 39.01.57 40.0

1350 15351470 16651630 1825

215 295 215255 335 245290 380 275

555

115-23-3661115-23-3663115-23-3667

4/0 107.0250 127.0350 177.0

1.39 1.451.42 1.481.52 1.58

80 2.0380 2.03

110 2.79

1.64 41.91.69 42.91.83 46.5

1840 20851985 22502495 2770

330 435 315365 475 345440 575 415

555

115-23-3671115-23-3675115-23-3677

500 253.0750 380.0

1000 507.0

1.63 1.691.81 1.871.97 2.02

110 2.79110 2.79110 2.79

1.94 49.32.12 53.92.27 57.6

3085 35554055 46805980 5630

535 700 500655 865 610755 1005 690

668

Okoguard Insulation: 345 mils (8.76mm), 100% Insulation Level

Aluminum Conductors(1) Aluminum conductors are available on special order.Ampacities(2) Ampacities are in accordance with Table 311.60(C)(73) of the NEC for threesingle Type MV-105 conductors, or single conductors twisted together (triplexed)and installed in an isolated conduit in air at an ambient temperature of 40°C and aconductor temperature of 105°C.(3) Ampacities are in accordance with Table 311.60(C)(81) of the NEC for aninsulated single conductor directly buried with a conductor temperature ratingof 105°C, ambient earth temperature of 20°C, 100% Load Factor, thermalresistance (RHO) of 90, 7 1/2 inch spacing between conductor center lines, and24 inch spacing between circuits.

Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin for installation in duct banks, multiple point groundedshields, other ambient temperatures, circuit configurations or installationrequirements.(5) Recommended size of rigid or nonmetallic conduit for three conductorsbased on 40% maximum fill.* The jam ratio conduit I.D. to cable O.D. should be checked to avoid possiblejamming.

(4) Ampacities are in accordance with Table 311.60(C)(77) of the NEC for threesingle conductors or triplexed cable in one underground raceway, three feet deepwith a conductor temperature of 105°C, 100% Load Factor, an ambient earthtemperature of 20°C, and thermal resistance (RHO) of 90.

Okonite’s web site, www.okonite.com contains the most up to date information.

UL®

Okoguard -Okoseal® ®

69kV Shielded Power CableConductor/105°C Rating - 100% Insulation Level

A Uncoated, Okopact (Compact)or Compress Stranded Copperor Aluminum ConductorStrand Screen-ExtrudedBSemiconducting EPRInsulation-Okoguard EPRCInsulation Screen-ExtrudedDSemiconducting EPRShield-5 Mil Uncoated CopperETapeJacket-OkosealF

Product DataSection 2: Sheet 18

InsulationOkoguard is Okonite's registered tradename for its exclusive ethylene-propylenerubber (EPR) based, thermosettingcompound, whose optimum balance ofelectrical and physical properties isunequaled in other solid dielectrics.Okoguard insulation, with the distinctivered color and a totally integrated EPRsystem, provides the optimum balance ofelectrical and physical properties for long,problem free service.The triple tandem extrusion of the screenswith the insulation provides optimumelectrical characteristics.

JacketThe Okoseal (PVC) jacket supplied withthis cable is mechanically rugged and hasexcellent resistance to oil and mostchemicals.

ApplicationsOkoguard-Shielded-Okoseal 69kV Cablesare designed for use as primary circuits inelectrical utility and industry applicationswhere they provide maximum circuitsecurity and economical installation.Rated 105°C for continuous operatingtemperature, Okoguard 69kV cables maybe installed in wet or dry locations indoorsor outdoors (exposed to sunlight) inunderground ducts, conduits or directburial.

SpecificationsConductors: Uncoated copper sizes 350through 1000 kcmil compact roundstranding per ASTM B-496. Uncoatedcopper sizes larger than 1000 kcmilcompress round stranding per ASTM B-8.EC Aluminum per ASTM B609, Class Bstranded per B-231.Strand Screen: Extruded semiconductingEPR strand screen. Meets or exceedselectrical and physical requirements ofICEA S-108-720, AEIC CS9.

Insulation: Meets or exceeds electricaland physical requirements of ICEAS-108-720 and AEIC Cs9.Insulation Screen: Extrudedsemiconducting EPR insulation screen.Meets or exceeds electrical andphysical requirements of ICEA S-108-720 and AEIC Cs9.Shield: 5 mil bare copper tape helicallyapplied with 25% nominal overlap.Jacket: Meets or exceeds electricaland physical requirements of ICEA S-108-720 for polyvinyl chloride jackets.Optional jackets include Okolene,Okolon TS-CPE, Okoclear and, whenspecified, a semi-conducting outerlayer.Optional shields include neutral wires,LCS and a combination of copper tapeand wires. A CLX armor covering isalso available.

Product Features• Triple tandem extruded, all EPRsystem.

• Okoguard cables meet or exceedrecognized industry standards (AEIC,NEMA/ ICEA).

• 105°C continuous operatingtemperature.

• 140°C emergency rating.

• 250°C short circuit rating.

• Excellent corona resistance.

• Exceptional resistance to “treeing."

• Low shield resistance.

• Moisture resistant.

• Resistant to most oils, acids, andalkalies.

• Sunlight resistant.

• Improved Temperature Rating.

• Screens are clean stripping.• Production testing and associatedfrequency to be performed inaccordance with ICEA S-108-720,latest edition.

Okoguard-Okoseal69kV Shielded Power CableConductor/105°C Rating100% Insulation Level

Okoguard Insulation: 650 mils(16.5mm)

Product DataSection 2: Sheet 18

Copper Conductor - Compact Round

115-22-3765115-22-3767

▲115-22-3771115-22-3775

250 127350 177500 253750 380

1.91 2.012.01 2.112.12 2.222.30 2.40

110 2.79110 2.79110 2.79110 2.79

2.26 57.42.36 59.92.47 62.72.64 67.1

3086 34593538 38734179 45145213 5805

444 398550 495667 599825 742

3½3½3½4

▲115-22-3777 1000 507 2.44 2.54 140 3.56 2.85 72.4 6389 7151 957 861 4

Copper Conductor - Compress Round

115-22-3778 1250 633 2.68 2.78 140 3.56 3.09 78.5 7582 8344 1066 959 5

115-22-3779 1500 761 2.78 2.88 140 3.56 3.19 81.0 8527 9447 1157 1042 5

G/20080218THE OKONITE COMPANY

Ramsey, New Jersey 07446

Catalo

g Num

ber

Conductor s

ize

AWG

or kcm

il

Conductor S

ize

-mm

²

Approx. D

ia. o

ver

Insula

tion (i

n.)

Approx. D

ia. o

ver

Screen (i

n.)

Jacket Thic

kness- m

ils

Jacket Thic

kness- m

m

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

Approx. N

et Weig

ht

lbs./1

000’

Approx. S

hip W

eight

lbs./1

000’

Ampaciti

es(1

) Dire

ct Buria

l

Ampaciti

es(1

)

Undergro

und Duct

Conduit Siz

e

Inches

(2)*

▲ Available from our Customer Service Centers.Authorized Stock Item.

Additional conductor sizes are available.

Ampacities

(1) Ampacities are in accordance with ICEA P-53-426 for threesingle 69kV conductors directly buried or in individual ducts underground, 36"deep with 7 1/2" spacing between conductors, at 105°C maximum conductortemperature, 25°C earth temperature, soil resistivity of 90 Rho, 100% loadfactor, and open circuit shields.

(2) Recommended size of rigid nonmagnetic or nonmetallic conduit for a singleconductor based on 53% maximum fill.

Aluminum Conductor - Compress Round

135-22-3765135-22-3767135-22-3771135-22-3775

250 127350 177500 252750 380

1.94 2.042.06 2.162.19 2.292.37 2.47

110 2.79110 2.79110 2.79110 2.79

2.29 58.22.41 61.22.54 64.52.72 69.1

2614 32002888 32233244 35793778 4175

348 312429 386523 469650 584

3½3½3½4

135-22-3777135-22-3778

1000 5071250 633

2.52 2.622.68 2.78

140 3.56140 3.56

2.93 74.43.09 78.5

4433 49044954 5716

759 683853 768

45

135-22-3779 1500 761 2.80 2.90 140 3.56 3.21 81.5 5381 6034 936 842 5

Okonite’s web site, www.okonite.com contains the most up to date information.

Okoguard -Okoseal Type MV-105® ®

5/8kV Okoguard Shielded Power Cable3 Okopact (Compact Stranded) Copper Conductor/105°C Rating

®

5kV-133% or 8kV-100% Insulation LevelFor Cable Tray Use-Sunlight Resistant-For Direct Burial

A Uncoated Okopact (CompactStranded) Copper ConductorExtruded Semiconducting EPRBStrand Screen

C Okoguard Insulation (EPR)D Extruded Semiconducting EPR

Insulation ScreenE Phase Identification TapeF Okopact Compact Copper

Grounding ConductorG Uncoated Copper ShieldH Fillers and Binder TapeJ Jacket-Black Okoseal

COMPACT STRAND

CONSTRUCTION Product DataSection 2: Sheet 19

Grounding Conductor: Uncoated coppercompact stranded per ASTM B-496 andsized in accordance with UL 1072.Assembly: Cabled with fillers and groundwire in the interstices, binder tape overall.Jacket: Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74, CSA C68.10 and UL1072 for polyvinyl chloride jackets.

UL Listed as Type MV-105, sunlightresistant for use in cable tray, and fordirect burial in accordance with UL 1072.

Cables listed to CSA C68.10

Product Features• Triple tandem extruded, all EPRsystem.

• Complete prepackaged, color coded,factory tested wiring system.• Passes the UL 1072, IEEE 383 andIEEE 1202/FT4 Vertical Tray Flame Tests.• Complies with NEC Section 336.36 andis suitable for direct buried when installedin accordance with NEC Sections250.4(A)(5).• Minimum installation temperature of-40°C.• Excellent corona resistance.• Screens and clean stripping.• Exceptional resistance to “treeing”.• Improved Temperature Rating.• Sizes 4/0 AWG and larger are CSAlisted as FT4, SR, LTGG (-40°C), and TC-ER.• Sizes smaller than 4/0 AWG are CSAlisted as FT4, SR, and LTDD (-25°C).

InsulationOkoguard Is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) base, thermosetting compound, whoseoptimum balance of electrical and physicalproperties is unequaled in other soliddielectrics. Okoguard insulation, with thedistinctive red color and a totally integratedEPR system, provides the optimum balance ofelectrical and physical properties for long,problem free service.

AssemblyThe Type MV-105 conductors are assembledwith fillers and a binder tape overall. One barestranded copper ground conductor is placedin one of the outer interstices.

JacketThe Okoseal (PVC) jacket supplied with thiscable is mechanically rugged and hasexcellent resistance to oil and mostchemicals.

ApplicationsOkoguard shielded three conductor Type MV-105 power cables are recommended fordistribution circuits, and for feeders or branchcircuits in industrial & utility power distributionsystems. Type MV cables may be installed inwet or dry locations, indoors or outdoors(exposed to sunlight), in any raceway orunderground duct, directly buried, cable tray,or messenger supported in industrialestablishments and electric utilities.

SpecificationsConductors: Uncoated copper compactstranded per ASTM B-496.Strand Screen: Extruded semiconductingEPR strand screen meets or exceedselectrical and physical requirements of ICEAS-93-639/NEMA WC74, CSA C68.10 and UL1072.Insulation: Okoguard meets or exceeds theelectrical and physical requirements of ICEAS-93-639/NEMA WC74, CSA C68.10 and UL1072. The insulated conductors are tested inaccordance with AEIC CS8.Insulation Screen: Extruded semiconductingEPR insulation screen per ICEA S-93-639/NEMA WC74, AEIC CS8, CSA C68.10and UL 1072.Shield: 5 mil uncoated copper tape helicallyapplied with 12.5% nominal overlap.Phase Identification: Color coded (black,red, blue) polyester ribbon laid longitudinallyunder the copper shield.

UL®

Product DataSection 2: Sheet 19

N/21060219

THE OKONITE COMPANYRamsey, New Jersey 07446

Cat

alog N

umber

(1)

Conduct

or siz

e

(AW

G o

r kcm

il)

Conduct

or Siz

e -m

Appro

x. D

iam

eter

ove

r

Insu

latio

n (in.)

Gro

unding

Conduct

or Size

(AW

G/k

cmil)

Jack

et T

hickn

ess

- mm

Appro

x. C

ore O

.D. -

Inch

es

Appro

x. Net W

eight

lbs./1

000’

Appro

x. Ship

Weig

ht

lbs./1

000’

Am

pacities

inCable

Tray

(2)

Am

pacities

Dire

ct Buria

l (3)

▲ Available from our Customer Service Centers.Authorized stock item.Aluminum Conductors

Aluminum conductors are available on special order.(1)Ampacities(2) Ampacities are in accordance with Table 311.60(C)(71) of the NEC for aninsulated three conductor cable, isolated in air, with a conductor operating tem-perature of 105°C and an ambient air temperature of 40°C.

Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacities, or the OkoniteEngineering Data Bulletin for installation in duct banks, other ambient tempera-tures, circuit configurations or installation requirements.

(3) Ampacities are in accordance with Table 311.60(C)(83) of the NEC for aninsulated three conductor cable directly buried in the earth with a conductor op-erating temperature of 105°C, ambient earth temperature of 20°C, 100% loadfactor and thermal resistance (RHO) of 90.

Okonite’s web site, www.okonite.com contains the most up to date information.

Okoguard -Okoseal Type MV-105® ®

5/8kV Okoguard Shielded Power Cable3 Okopact (Compact Stranded) Copper Conductor/105°C Rating

®

5kV-133% or 8kV-100% Insulation LevelFor Cable Tray Use-Sunlight Resistant-For Direct Burial

Okoguard Insulation: 115 mils (2.92mm), 5kV-133% or 8kV-100% Insulation Level

▲114-23-3630114-23-3633

6 13.34 21.2

0.440.48

6 13.36 13.3

1.10 27.91.19 30.2

80 2.0380 2.03

1.29 32.81.38 35.1

1015 11151235 1390

88 115115 150

▲114-23-3640114-23-3642

2 33.61/0 53.5

0.540.61

6 13.34 21.2

1.32 33.51.46 37.0

80 2.0380 2.03

1.51 38.31.65 41.9

1560 17152090 2250

155 190205 245

▲114-23-3648▲114-23-3736

114-23-3770

2/0 67.44/0 107.0

250 127.0

0.650.750.80

4 21.23 26.72 26.7

1.55 39.41.77 45.01.88 47.8

110 2.79110 2.79110 2.79

1.80 45.72.02 51.32.13 54.1

2513 26953455 37803961 4245

240 280320 360355 395

▲114-23-3772▲114-23-3782

350 177.0500 253.0

0.891.01

2 33.61 42.4

2.08 52.82.33 59.2

110 2.79110 2.79

2.33 59.22.59 65.8

5116 56656799 7430

440 475545 570

Jack

et T

hickn

ess

- mils

Gro

unding

Conduct

or

Size

- mm

²

Appro

x. C

ore O

.D. -

mm

Appro

x. O.D

. -In

ches

Appro

x. O.D

. -m

m

For 8kV ampacities refer to the NEC tables referenced below in the columns listed 5001-35,000 Volts

UL®

Okoguard Okoseal Type MV-105® ®

15kV Okoguard Shielded Power Cable3 Okopact (Compact Stranded) Copper Conductors/105°C Rating

®

100% & 133% Insulation LevelFor Cable Tray Use-Sunlight Resistant-For Direct Burial

A Uncoated Okopact (CompactStranded) Copper ConductorsExtruded Semiconducting EPRBStrand Screen

C Okoguard Insulation (EPR)D Extruded Semiconducting EPR

Insulation ScreenE Phase Identification TapeF Okopact Copper Grounding

ConductorG Uncoated Copper ShieldH Fillers and Binder TapeJ Jacket-Black Okoseal

COMPACT STRAND

CONSTRUCTION Product DataSection 2: Sheet 20

InsulationOkoguard Is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) base, thermosetting compound, whoseoptimum balance of electrical and physicalproperties is unequaled in other soliddielectrics. Okoguard insulation, with thedistinctive red color and a totally integratedEPR system, provides the optimum balanceof electrical and physical properties for long,problem free service.

AssemblyThe Type MV-105 conductors areassembled with fillers and a binder tapeoverall. One bare stranded copper groundconductor is placed in one of the outerinterstices.

JacketThe Okoseal (PVC) jacket supplied with thiscable is mechanically rugged and hasexcellent resistance to oil and mostchemicals.

ApplicationsOkoguard shielded three conductor OkosealType MV-105 power cables arerecommended for distribution circuits, andfor feeders or branch circuits in industrialand utility power distribution systems. TypeMV cables may be installed in wet or drylocations, indoors or outdoors (exposed tosunlight), in any raceway or undergroundduct, directly buried, cable tray, ormessenger supported in industrialestablishments and electric utilities.

SpecificationsConductors: Uncoated copper compactstranded per ASTM B-496.Strand Screen: Extruded semiconductingEPR strand screen meets or exceedselectrical and physical requirements of ICEAS-93-639/NEMA WC74, CSA C68.10 andUL 1072.Insulation: Okoguard meets or exceeds theelectrical and physical requirements of ICEAS-93-639/NEMA WC74, CSA C68.10 andUL 1072. The insulated conductors aretested in accordance with AEIC CS8.Insulation Screen: Extrudedsemiconducting EPR insulation screen perICEA S-93-639/NEMA WC74, AEIC CS8,CSA C68.10 and UL 1072.Shield: 5 mil uncoated copper tape helicallyapplied with 12.5% nominal overlap.

Phase Identification: Color coded (black,red, blue) polyester ribbon laidlongitudinally under the copper tapeshield.Grounding Conductor: Uncoated coppercompact stranded per ASTMB-496 and sized in accordance with UL1072.Assembly: Cabled with fillers and groundwire in the interstices, binder tape overall.Jacket: Meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMA WC74, CSA C68.10 and UL1072 for polyvinyl chloride jackets.

UL Listed as Type MV-105, sunlightresistant for use in cable tray, and fordirect burial in accordance with UL 1072.

Cables listed to CSA C68.10Product Features

• Triple tandem extruded, all EPR system.

• Complete prepackaged, color coded,factory tested wiring system.

• Passes the UL 1072, IEEE 383 andIEEE 1202/FT4 Vertical Tray Flame Tests.

• Complies with NEC Section 336.6 and issuitable for direct buried when installed inaccordance with NEC Sections250.4(A)(5).

• Minimum installation temperature of

-40°C.

• Excellent corona resistance.• Screens are clean stripping.• Exceptional resistance to “treeing”.• Improved Temperature Rating.• Sizes 4/0 AWG and larger are CSA listedas FT4, SR, LTGG (-40°C), and TC-ER.• Sizes smaller than 4/0 AWG are CSAlisted as FT4, SR, and LTDD (-25°C).

UL®

Okonite’s web site, www.okonite.com contains the most up to date information.

Okoguard Okoseal Type MV-10515kV Okoguard Shielded Power Cable3 Okopact (Compact Stranded) Copper Conductors/105°C Rating

®

100% & 133% Insulation LevelFor Cable Tray Use-Sunlight Resistant-For Direct Burial

Product DataSection 2: Sheet 20

Cata

log

Num

ber(1

)

Conducto

r size

AWG

or kcmil

Conducto

r Size

-mm

²

Appro

x. D

ia. o

ver

Insu

latio

n (in.)

Jacket Thic

kness- m

ils

Jacket Thic

kness- m

m

Appro

x. O

.D. -

Inch

es

Appro

x. O

.D. -

mm

Appro

x. N

et W

eight

lbs.

/100

0’

Appro

x. S

hip W

eight

lbs.

/100

0’

Am

paciti

es in

Cab

le T

ray

(2)

Okoguard Insulation: 175 mils (4.45mm), 100% Insulation Level

115-23-3766115-23-3768

2 33.61/0 53.5

0.670.74

6 13.34 21.2

1.59 40.41.74 44.2

110 2.79110 2.79

1.83 46.51.97 50.0

1985 21302560 2770

185 200240 255

115-23-3770115-23-3772115-23-3774

2/0 67.44/0 107.0

250 127.0

0.780.880.93

4 21.23 26.73 26.7

1.82 42.22.04 51.82.15 54.6

110 2.79110 2.79110 2.79

2.06 52.32.28 57.92.39 60.7

2890 31503905 41904390 4930

275 290360 375400 410

115-23-3776115-23-3778115-23-3780

350 177.0500 253.0750 380.0

1.031.141.32

2 33.61 42.4

1/0 53.5

2.36 59.92.61 66.32.99 75.9

110 2.79140 3.56140 3.56

2.59 65.82.91 73.93.29 83.6

5608 62107480 8255

10320 11330

490 495600 590745 720

Okoguard Insulation: 220 mils (5.59mm), 133% Insulation Level

▲115-23-3802115-23-3804

2 33.61/0 53.5

0.760.83

6 13.34 21.2

1.79 45.51.93 49.0

110 2.79110 2.79

2.02 51.32.17 55.1

2280 25752857 3145

185 200240 255

▲115-23-3806▲115-23-3808

115-23-3810

2/0 67.44/0 107.0

250 127.0

0.870.971.03

4 21.23 26.73 26.7

2.02 51.32.24 56.92.36 60.0

110 2.79110 2.79110 2.79

2.26 57.42.48 63.02.59 65.8

3260 35704285 46404795 5295

275 290360 375400 410

▲115-23-3812▲115-23-3814

115-23-3816

350 177.0500 253.0750 380.0

1.121.241.41

2 33.61 42.4

1/0 53.5

2.56 65.02.81 71.43.19 81.0

140 3.56140 3.56140 3.56

2.85 72.43.10 78.73.49 88.7

6168 70007895 8945

10805 11800

490 495600 590745 720

Gro

unding

Conduct

or

Sizes

- Aw

g/kcm

il

Gro

unding C

onductor

Sizes

- m

Appro

x. C

ore O

.D. -

Inch

es

Approx. C

oreO

.D. -

mm

Am

paciti

es

Dire

ct B

urial (

3)

(3) Ampacities are in accordance with Table 311.60(C)(83) of the NEC for aninsulated three conductor cable directly buried in the earth with a conductoroperating temperature of 105°C, ambient earth temperature of 20°C, 100%load factor, thermal resistance (RHO) of 90.

Refer to the NEC, lEEE/lCEA S-135 Power Cable Ampacities or the OkoniteEngineering Data Bulletin for installation in duct banks, other ambienttemperatures, circuit configurations or installation requirements.

▲ Available from our Customer Service Centers.Authorized stock item.

Aluminum Conductors

(1) Aluminum conductors available on special orders.

Ampacities

(2) Ampacities are in accordance with Table 311.60(C)(71) of the NEC for an insulated threeconductor cable, isolated in air, with a conductor operating temperature of 105°C and an ambient airtemperature of 40°C.

L/21060220

THE OKONITE COMPANYRamsey, New Jersey 07446

UL®

C-L-X VFD Type MV-90 or MC-HL®

2.4kV Okoguard Nonshielded Power Cable-Aluminum Sheath5000V CSA RA90

3 Okopact (Compact Stranded) Copper Conductors/90°C Rating®

100% & 133% Insulation LevelFor Cable Tray Use-Sunlight Resistant-For Direct Burial

A Uncoated Okopact (CompactStranded) Copper ConductorExtruded Semiconducting EPRBStrand Screen

C Okoguard (EPR) InsulationD Three Copper Grounding

ConductorsE Phase IdentificationF Fillers and Binder TapeG Impervious, Continuous,

Corrugated Aluminum C-L-XSheath

H Jacket-Low Temperature YellowOkoseal

COMPACT STRAND

CONSTRUCTION Product DataSection 2: Sheet 21

®

3X

8A

WG

CU

GR

D C

LX

VF

D (

UL

) M

V-9

0 M

C-H

L

physical requirements of ICEA S-96-659/NEMA WC71 and UL 1072.Insulation: Okoguard meets or exceeds theelectrical and physical requirements ofICEA S-96-659/NEMA WC71 and UL 1072.Phase Identification: Print color code (black,red and blue).Grounding Conductors: Three uncoatedcopper Class B in accordance with UL1072.Assembly: Cabled with fillers and groundwires, in the interstices, binder tape overall.Sheath: Close fitting, impervious,continuous, corrugated aluminum C-L-X perUL 1072. C-L-X is recognized as agrounding conductor by NEC.Jacket: A low temperature sunlightresistant, yellow PVC jacket in accordancewith UL 1072. Other color jackets areavailable.UL Listed as type MV-90 or MC-HL,sunlight resistant, for use in cable tray, andfor direct burial in accordance with UL 1072and 2225.

Product Features• Tandem extruded, all EPR system.• Complete prepackaged, color coded,factory tested wiring system.• Okoguard C-L-X cables meet or exceedelectrical and physical requirements of allrecognized industry standards (UL, AEIC,NEMA/ICEA, IEEE).

• Passes the vertical tray flame test

requirements of IEEE 383 and 1202, UL

1072, ICEA T-29-520(210,000 BTU/hr.)• Complies with NEC Section 336.36 and issuitable for direct buried when installed inaccordance with NEC Sections 250.4(A)(5).• Complies with NEC Articles 501, 502, 503and 505 for hazardous locations.• Continuous sheath provides groundingsafety.• Excellent corona resistance.• Exceptional resistance to "treeing."• Stress cones not required.• Minimum installation temperature of -40°C.• Three symmetrical grounding conductorswith the CLX sheath provide a superior lowresistance return path for VFD and othermodern ac drive/motor applications.• ABS listed as CWCMC Type MC-HL.• CSA listed as RA90, FT4, SR, HL, -40°Cand 5000V.

InsulationOkoguard is Okonite's registered trade name forits exclusive ethylene-propylene rubber (EPR)base, thermosetting compound, whose optimumbalance of electrical and physical properties isunequaled in other solid dielectrics. Okoguardinsulation, with the distinctive red color and atotally integrated EPR system, provides theoptimum balance of electrical and physicalproperties for long, problem free service.

AssemblyThe Type MV-90 conductors are assembled withfillers and a binder tape into a round core. Threebare stranded copper grounding conductors,located in the outer interstices, is provided forgrounding. A continuously corrugated weldedaluminum sheath C-L-X encases the cable core.The C-L-X sheath is protected with a lowtemperature yellow Okoseal (PVC) jacket. The®

impervious, continuous, corrugated aluminum C-L-X sheath provides complete protection againstmoisture, liquids and gases in addition to itsexcellent mechanical strength. In addition, thealuminum CLX sheath exceeds the equipmentgrounding requirements of NEC Section 250.118and 250.122, and can be used as the equipmentgrounding conductor in non-HL areas. Theoverall Okoseal (PVC) jacket allows the cable tobe direct buried in the ground, embedded inconcrete or areas subjected to a corrosiveatmosphere.

ApplicationsC-L-X power cables are recommended as aneconomical alternate to a wire in conduit system.They are designed specifically for use onfeeders and branch circuits in industrial powerdistribution systems. C-L-X power cables maybe installed in both exposed and concealedwork, wet and dry locations, direct burial in theearth, or embedded in concrete. They may beinstalled on metal racks, troughs, in cable traysor secured to supports not greater than 6 feetapart. C-L-X power cables are also approved forClasses I, II and III. Divisions 1 and 2 and ClassI, Zones 1 and 2 hazardous locations - NECArticles 501, 502, 503 and 505.Medium voltage Non-Shielded cables dischargenormally in service when spacing betweenphases is non-uniform or when phases are inclose proximity to a grounded surface.

SpecificationsConductors: Annealed uncoated coppercompact stranded per ASTM B-496.Strand Screen: Extruded semiconducting EPRstrand screen meets or exceeds electrical and

UL®

C-L-X VFD Type MV-90 or MC-HL2.4kV Okoguard Nonshielded Power Cable-Aluminum Sheath5000V CSA RA90

3 Okopact (Compact Stranded) Copper Conductors/90°C Rating®

100% & 133% Insulation LevelFor Cable Tray Use-Sunlight Resistant-For Direct Burial

Product DataSection 2: Sheet 21

Okoguard Insulation: 90 mils (2.29mm)

Catalo

g Num

ber (1

)

Conductor s

ize

(AW

G o

r kcm

il)

Conductor S

ize -m

Approx. D

iam

eter o

ver

Insula

tion (i

n.)

Jacket Thic

kness mils

Jacket Thic

kness mm

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

Approx. N

et Weig

ht

lbs./1

000’

Approx. S

hip W

eight

lbs./1

000’

Ampaciti

es in

Cable T

ray (2

)

With Yellow Okoseal Jacket

571-21-3193571-21-3196

▲571-21-3200

8 8.46 13.34 21.2

0.360.390.44

3x123x103x10

0.77 19.60.85 21.60.97 24.6

0.971.061.19

50 1.2750 1.2750 1.27

1.08 27.41.17 29.71.30 33.0

565 630740 820960 1050

59 8579 105

105 135

▲571-21-3204571-21-3208571-21-3212

2 33.61 42.4

1/0 53.5

0.500.520.56

3x103x83x8

1.10 27.91.16 29.41.23 31.2

1.341.421.51

50 1.2750 1.2760 1.52

1.45 36.81.53 38.91.65 41.9

1270 14701520 16601835 1980

140 180160 200185 230

▲571-21-3217▲571-21-3224

571-21-3228

2/0 67.44/0 107.0

250 127.0

0.600.700.75

3x83x73x6

1.33 33.81.53 38.91.64 41.7

1.601.831.96

60 1.5260 1.5260 1.52

1.73 43.91.96 49.82.09 53.1

2160 23253075 33403470 3725

215 260285 335320 365

▲571-21-3236▲571-21-3244

571-21-3248571-21-3252

350 177.0500 253.0750 380.0

1000 507.0

0.850.961.141.29

3x63x53x43x4

1.86 47.22.10 53.32.51 63.82.90 73.7

2.192.452.933.41

60 1.5275 1.9175 1.9185 2.16

2.32 58.92.61 66.33.10 78.73.59 91.2

4705 52656405 69659220 980

12075 13155

395 440485 530615 650705 730

Gro

unding C

onductors

No. x S

ize (A

WG

/kcm

il)

Approx. C

ore O

.D. -

Inches

Approx. C

ore O

.D. -

mm

Ampaciti

es

Direct B

urial (

3)

Okonite’s web site, www.okonite.com contains the most up to date information.

▲ Available from our Customer Service Centers.Authorized stock item.

Copper or bronze and non-jacketed C-L-X is available on special order.

JacketsOptional jacket types available - consult local sales office.

Aluminum Conductors

(1) Aluminum conductors are available on special order.

AmpacitiesAmpacities are in accordance with Table 311.60(C)71 of the NEC for an(2)

insulated three conductor cable, isolated in air, with a conductor operatingtemperature of 90°C and an ambient air temperature of 40°C.

(3) Ampacities are in accordance with Table 311.60(C)83 of the NEC for aninsulated three conductor cable directly buried in the earth with a conductoroperating temperature of 90°C, ambient earth temperature of 20°C, 100% loadfactor and thermal resistance (RHO) of 90.

Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacity Tables, or theOkonite Engineering Data Bulletin for installation in duct banks, other ambienttemperatures, circuit configurations or installation requirements.

C-L-X The Okonite Company

Q/21060221

THE OKONITE COMPANYRamsey, New Jersey 07446

C-L-X

O.D

- In

ches

®

UL®

C-L-X VFD Type MV-105 or MC-HL®

5/8kV Okoguard Shielded Power Cable-Aluminum Sheath5000V CSA RA903 Okopact (Compact Stranded) Copper Conductors/105°C Rating5kV - 133% or 8kV - 100% Insulation LevelFor Cable Tray Use-Sunlight Resistant-For Direct Burial

A Uncoated (Compact Stranded)Copper ConductorsExtruded Semiconducting EPRBStrand Screen

C Okoguard Insulation (EPR)D Extruded Semiconducting EPR

Insulation ScreenE Phase Identification TapeF Three Copper Grounding

ConductorsG Uncoated Copper ShieldH Fillers and Binder TapeJ Impervious, continuous,

Corrugated Aluminum C-L-X SheathJacket-Yellow OkosealK

COMPACT STRAND

CONSTRUCTION Product DataSection 2: Sheet 22

®

InsulationOkoguard Is Okonite's registered trade name forits exclusive ethylene-propylene rubber (EPR)base, thermosetting compound, whose optimumbalance of electrical and physical properties isunequaled in other solid dielectrics. Okoguardinsulation, with the distinctive red color and atotally integrated EPR system, provides theoptimum balance of electrical and physicalproperties for long, problem free service.

AssemblyType MV-105 conductors are assembled withfillers, three bare stranded grounding conductorsand a binder tape into a round core. Acontinuously corrugated welded aluminum sheath(C-L-X) encases the cable core. The C-L-Xsheath is protected with a low temperatureyellow Okoseal jacket. The impervious,

®

continuous, corrugated aluminum C-L-X sheathprovides complete protection against moisture,liquids and gases in addition to its excellentmechanical strength. In addition, the aluminumCLX sheath exceeds the equipment groundingrequirements of NEC Section 250.118 and250.122, and can be used as the equipmentgrounding conductor in non-HL areas. TheOkoseal jacket allows the cable to be directburied in the ground, embedded in concrete orareas subjected to corrosive atmospheres.

ApplicationsC-L-Xpower cables are recommended as aneconomical alternate to a wire in conduit system.They are designed specifically for use as feedersor branch circuits in industrial and utility powerdistribution systems. C-L-Xpower cables may beinstalled in both exposed and concealed work,wet and dry locations, directly buried in the earth,or embedded in concrete. They may be installedon metal racks, troughs, in cable trays or securedto supports not greater than 6 feet apart.C-L-X Type MC-HL cables are also approved forClasses I, II, and III, Division 1 and 2 and Class I,Zones 1 and 2 hazardous locations - NECArticles 501, 502, 503 and 505.

SpecificationsConductors: Uncoated copper compactstranded per ASTM B-496.Strand Screen: Extruded semiconducting EPRstrand screen meets or exceeds electrical andphysical requirements of ICEA S-93-639/NEMAWC74 and UL 1072.Insulation: Okoguard meets or exceeds theelectrical and physical requirements of ICEA S-93-639/NEMA WC74 and UL 1072. The insul-

lated conductors are tested in accordancewith AEIC CS8.Insulation Screen: Extruded semiconductingEPR insulation screen per ICEA S-93-639/NEMA WC74, AEIC CS8 and UL 1072.Shield: 5 mil uncoated copper tape helicallyapplied with 12.5% nominal overlap.Phase Identification: Color coded (black, red,blue) polyester ribbon laid longitudinallyunder the copper shield tape.Grounding Conductors: Three uncoatedcopper in accordance with UL 1072.Assembly: Cabled with fillers and groundwires in the interstices, binder tape overall.Sheath: Close fitting, impervious, continuous,corrugated aluminum C-L-Xper UL 1072; C-L-Xis recognized as a grounding conductorby NEC.Jacket: A low temperature, sunlight resistant,yellow PVC jacket in accordance with UL1072. Other color jackets are available.UL Listed as type MV-105 or MC-HL, sunlightresistant for use in cable tray, and for directburial in accordance with UL 1072 & 2225.CSA Listed to C68.10.

Product Features• Triple tandem extruded, all EPR system.• Complete prepackaged, color coded,factory tested wiring system.• Okoguard C-L-X cables meet or exceed allrecognized industry standards (UL, AEIC,NEMA/ICEA, IEEE).• Passes the vertical tray flame testrequirements of IEEE 383 and 1202, UL1072, ICEA T-29-520 (210,000 BTU/hr.).• Complies with NEC Section 336.36 and issuitable for direct buried when installed inaccordance with NEC Sections 250.4(A)(5).• Complies with NEC Articles 501, 502, 503and 505 for hazardous locations.• Continuous sheath provides groundingsafety.• Excellent corona resistance.• Screens are clean stripping.• Exceptional resistance to "treeing".• Minimum installation temperature of -40°C.• Improved Temperature Rating.• Three symmetrical grounding conductorswith the CLX sheath provide a superior lowresistance return path for VFD and othermodern ac drive/motor applications.• ABS listed as CWCMC Type MC-HL.• CSA listed as FT4, SR, HL and LTGG(-40°C).

ULR

C-L-X VFD Type MV-105 or MC-HL5/8kV Okoguard Shielded Power Cable-Aluminum Sheath3 Okopact (Compact Stranded) Copper Conductors/105°C Rating100% & 133% Insulation LevelFor Cable Tray Use-Sunlight Resistant-For Direct Burial

Product DataSection 2: Sheet 22

Okoguard Insulation: 115 mils (2.92mm), 5kV-133% or 8kV-100% Insulation Level

Catalo

g Num

ber (1

)

Conduct

or si

ze

(AW

G o

r kc

mil)

Conduct

or Siz

e -m

Appro

x. D

iam

eter

ove

r

Insu

latio

n (in.)

Jack

et T

hickn

ess

mils

Jack

et T

hickn

ess

mm

Appro

x. O

.D. -

Inch

es

Appro

x. O

.D. -

mm

Appro

x. N

et W

eight

lbs.

/100

0’

Appro

x. S

hip W

eight

lbs.

/100

0’

Am

paciti

es in

Cab

le T

ray

(2)

With Yellow Okoseal Jacket

* 571-22-3694571-22-3696

▲571-22-3698

8 8.46 13.34 21.2

0.400.440.48

3x123x103x10

1.04 26.41.12 28.41.21 30.7

1.291.371.51

50 1.2750 1.2760 1.52

1.40 35.61.48 37.61.65 41.9

907 10561090 12591398 1556

66 9088 115

115 150

▲571-22-3706571-22-3708571-22-3710

2 33.61 42.4

1/0 53.5

0.540.580.61

3x103x83x8

1.34 34.01.40 35.61.48 37.6

1.641.691.78

60 1.5260 1.5260 1.52

1.78 45.21.82 46.21.91 48.5

1732 18901992 21372273 3012

154 190180 215205 245

▲571-22-3717▲571-22-3725

571-22-3727

2/0 67.44/0 107.0

250 127.0

0.650.750.80

3x83x73x6

1.57 39.91.78 45.21.90 48.3

1.922.152.28

60 1.5260 1.5260 1.52

2.00 50.82.29 58.22.44 62.0

2616 41713613 39804175 4390

240 280320 360355 395

▲571-22-3838▲571-22-3846

571-22-3748571-22-3751

350 177.0500 253.0750 380.0

1000 507.0

0.891.011.191.34

3x63x53x43x3

2.10 53.32.35 57.62.73 69.33.11 79.1

2.452.753.243.67

75 1.9175 1.9185 2.1685 2.16

2.61 66.32.91 73.93.42 86.93.85 97.8

5328 54357095 7603

10134 1102113164 14794

440 475545 570685 700790 785

Gro

unding C

onductors

No. x

Siz

e (A

WG

/kcm

il)

Appro

x. C

ore O

.D. -

Inch

es

Appro

x. C

ore O

.D. -

mm

Am

paciti

es

Dire

ct B

urial (

3)

Okonite’s web site, www.okonite.com contains the most up to date information.

Q/21070222

THE OKONITE COMPANYRamsey, New Jersey 07446

C-L

-X O

.D -

Inch

es

▲ Available from our Customer Service Centers.Authorized stock item.

Copper or bronze C-L-X and non-jacketed C-L-X are available on special order.

JacketsOptional jacket types available - consult local sales office.

Aluminum Conductors

(1) Aluminum conductors are available on special order.

AmpacitiesAmpacities are in accordance with Table 311.60(C)(71) of the NEC for an(2)

insulated three conductor cable, isolated in air, with a conductor operatingtemperature of 105°C and an ambient air temperature of 40°C.

(3) Ampacities are in accordance with Table 311.60(C)(83) of the NEC for aninsulated three conductor cable directly buried in the earth with a conductoroperating temperature of 105°C, ambient earth temperature of 20°C, 100%load factor and thermal resistance (RHO) of 90.

Refer to the NEC, IEEE/ICEA S-135 Power Cable Ampacity Tables, or theOkonite Engineering Data Bulletin for installation in duct banks, other ambienttemperatures, circuit configurations or installation requirements.

C-L-X The Okonite Company®

For 8kV ampacities refer to the NEC tables referenced below in the columns listed 5001-35,000 Volts

* This cable is only rated 5kV (133%), due to UL limitations, it cannot be rated 8kV.

ULR

C-L-X Type MV-105 or MC-HL®

15kV Okoguard Shielded Power Cable-Aluminum Sheath3 Okopact (Compact Stranded) Copper Conductors/105°C Rating133% Insulation LevelFor Cable Tray Use-Sunlight Resistant-For Direct Burial

A Uncoated Okopact (CompactStranded) Copper ConductorsExtruded Semiconducting EPRBStrand Screen

C Okoguard Insulation (EPR)D Extruded Semiconducting EPR

Insulation ScreenE Phase Identification TapeF Copper Grounding ConductorG Uncoated Copper ShieldH Fillers and Binder TapeJ Impervious, Continuous,

Corrugated Aluminum C-L-X SheathJacket-Red Low TemperatureKOkoseal

COMPACT STRAND

CONSTRUCTION Product DataSection 2: Sheet 24

®

®C

OM

PA

CT

CU

OK

OG

UA

RD

EP

PV

C 1

5kV

sulated conductors are tested in accordancewith AEIC CS8.Insulation Screen: Extrudedsemiconducting EPR insulation screenmeets or exceeds electrical and physicalrequirements of ICEA S-93-639/NEMAWC74 and UL 1072.Shield: 5 mil uncoated copper tape helicallyapplied with 12.5% nominal overlap.Phase Identification: Color coded (black,red, blue) polyester ribbon laid longitudinallyunder the copper shield tape.Grounding Conductor: Uncoated copper inaccordance with UL 1072.Assembly: Cabled with fillers and groundwire in the interstices, binder tape overall.Sheath: Close fitting, impervious,continuous, corrugated aluminum C-L-XperUL 1072; C-L-X is recognized as agrounding conductor by NEC.Jacket: A low temperature, sunlightresistant, red PVC jacket in accordance withUL 1072. Other color jackets are available.UL Listed as type MV-105 or MC-HL,sunlight resistant, for use in cable tray, andfor direct burial in accordance with UL 1072and 2225. UL certified to IEEE 1580. CSAListed to C68.10.

Product Features• Triple tandem extruded, all EPR system.• Complete prepackaged, color coded,factory tested wiring system.• Okoguard C-L-X cables meet or exceedall recognized industry standards (UL, AEIC,NEMA/ICEA, IEEE).• Passes the vertical tray flame testrequirements of IEEE 383 and 1202, UL1072, ICEA T-29-520 (210,000 BTU/hr.)• Complies with NEC Section 336.36 and issuitable for direct buried when installed inaccordance with NEC Sections 250.4(A)(5).• Complies with NEC Articles 501, 502, 503and 505 for hazardous locations.• Continuous sheath provides groundingsafety.• Excellent corona resistance.• Screens are clean stripping.• Exceptional resistance to "treeing".• Minimum installation temperature of -40°C.• Improved Temperature Rating.• ABS listed as CWCMC Type MC-HL.• CSA listed as FT4, SR, HL and LTGG(-40°C).

InsulationOkoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) base, thermosetting compound, whoseoptimum balance of electrical and physicalproperties is unequaled in other soliddielectrics. Okoguard insulation, with thedistinctive red color and a totally integratedEPR system, provides the optimum balanceof electrical and physical properties for long,problem free service.

AssemblyThe Type MV-105 conductors are assembledwith fillers, one bare stranded groundingconductor and a binder tape into a roundcore. A continuously corrugated weldedaluminum sheath (C-L-X) encases the cablecore. The C-L-X sheath is protected with alow temperature red Okoseal jacket. The®

impervious, continuous, corrugated aluminumC-L-X sheath provides complete protectionagainst moisture, liquids and gases inaddition to its excellent mechanical strength.In addition, the aluminum CLX sheathexceeds the equipment groundingrequirements of NEC Section 250.118 and250.122, and can be used as the equipmentgrounding conductor in non-HL areas. TheOkoseal jacket allows the cable to be directburied in the ground, embedded in concreteor areas subjected to corrosive atmospheres.

ApplicationsC-L-X power cables are recommended as aneconomical alternate to a wire in conduitsystem. They are designed specifically foruse as feeders or branch circuits in industrialand utility power distribution systems. C-L-Xpower cables may be installed in bothexposed and concealed work, wet and drylocations, direct burial in the earth, orembedded in concrete. They may be installedon metal racks, troughs, in cable trays orsecured to supports not greater than 6 feetapart.C-L-X Type MC-HL cables are also approvedfor Classes , , and , Divisions 1 and 2I II III

and Class Zones 1 and 2 hazardousI ,

locations - NEC Articles 501, 502, 503 and505.

SpecificationsConductors: Uncoated copper compactstranded per ASTM B-496.Strand Screen: Extruded semiconductingEPR strand screen meets or exceedselectrical and physical requirements of ICEAS-93-639/NEMA WC74 and UL 1072.Insulation: Okoguard meets or exceeds theelectrical and physical requirements of ICEAS-93-639/NEMA WC74 and UL 1072. The in-

UL®

C-L-X Type MV-105 or MC-HL15kV Okoguard Shielded Power Cable-Aluminum Sheath3 Okopact (Compact Stranded) Copper Conductors/105°C Rating133% Insulation LevelFor Cable Tray Use-Sunlight Resistant-For Direct BurialOkoguard Insulation: 220 mils (5.59mm)

Product DataSection 2: Sheet 24

Catalo

g Num

ber (1

)

Conductor s

ize

(AW

G o

r kcm

il)

Conductor S

ize -m

Approx. D

iam

eter o

ver

Insula

tion (i

n.)

Jacket Thic

kness (m

ils)

Jacket Thic

kness mm

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

Approx. N

et Weig

ht

lbs./1

000’

Approx. S

hip W

eight

lbs./1

000’

Ampaciti

es in

Cable T

ray (2

)

With Red Okoseal Jacket

▲571-23-3504571-23-3508571-23-3512

2 33.61 42.4

1/0 53.5

0.760.790.83

644

1.79 45.51.86 47.31.94 49.3

2.152.232.32

60 1.5260 1.5275 1.91

2.28 57.92.36 60.02.48 63.0

2420 31472706 34043076 3674

185 200210 225240 255

▲571-23-3516▲571-23-3524

571-23-3528

2/0 67.44/0 107.0

250 127.0

0.870.971.03

432

2.03 51.62.24 57.02.36 60.0

2.412.632.76

75 1.9175 1.9175 1.91

2.57 65.32.79 70.92.92 74.2

3434 42194460 53855078 5845

275 290360 345400 410

▲571-23-3536▲571-23-3544▲571-23-3548

350 177.0500 253.0750 380.0

1.121.241.41

21

1/0

2.56 65.02.81 71.43.19 81.0

2.983.283.76

75 1.9175 1.9185 2.16

3.14 79.83.46 89.23.94 100.0

6264 73058221 9653

11317 13087

490 495600 590745 720

Gro

unding C

onductor

Size (A

WG

/kcm

il)

Approx. C

ore O

.D. -

Inches

Approx. C

ore O

.D. -

mm

Ampaciti

es

Direct B

urial (

3)

Okonite’s web site, www.okonite.com contains the most up to date information.

R/21060224

THE OKONITE COMPANYRamsey, New Jersey 07446

C-L-X

O.D

- In

ches

▲ Available from our Customer Service Centers.Authorized stock item.

JacketsOptional jacket types available - consult local sales office.

Copper or bronze C-L-X and non-jacketed C-L-X are available on special order.

Aluminum Conductors

(1) Aluminum conductors are available on special order.

Ampacities

(2) Ampacities are in accordance with Table 311.60(C)(71) of the NEC for aninsulated three conductor cable, isolated in air, with a conductor operatingtemperature of 105°C and an ambient air temperature of 40°C.

(3) Ampacities are in accordance with Table 311.60(C)(83) of the NEC for an

insulated three conductor cable directly buried in the earth with a conductor

operating temperature of 105°C, ambient earth temperature of 20°C, 100%

load factor, thermal resistance (RHO) of 90.

Refer to the NEC, IEEE 835 Power Cable Ampacity Tables, or theOkonite Engineering Data Bulletin for installation in duct banks, other ambienttemperatures, circuit configurations or installation requirements.

C-L-X The Okonite Company®

UL®

Solid Type PILC15kV Paper Insulated Lead Covered Power CableThree Copper Conductors/90°C Rating100% Insulation Level

A Conductor-StrandedCompact Sector, Pre-twisted

B Strand Screen-CarbonBlack Paper Tapes

C Insulation-ImpregnatedPaper Tapes

D Insulation Screen-CarbonBlack Paper Tape

E Shield Copper TapeF Fillers-Impregnated

PaperG Binder Copper TapeH Sheath-Copper Bearing LeadJ Jacket

Product DataSection 2: Sheet 31

ConductorOkonite's multiconductor PILC cables are available

with three different style conductors depending on

the application. The three conductor styles are

compressed round, compact round and compact

(120°) sector.

InsulationOkonite's impregnated paper insulation consists of

the finest electrical grade paper made from the

highest quality coniferous wood pulp and the

purest polybutene dielectric fluid. The paper is

manufactured to meet Okonite specifications to

produce the necessary mechanical and physical

properties to resist tearing and wrinkling during

manufacture and subsequent handling during field

operations; and in addition to assure properties of

low dielectric loss with high dielectric strength. To

maintain a smooth, wrinkle-free precisely gapped

tape insulation, Okonite carefully slits it own paper

tapes into widths tailored for each conductor size

and wall thickness. Most importantly, Okonite has

the most precise tape tensions available.

The impregnating fluid used is a medium viscosity

polybutene type with an optional high viscosity

fluid for warm installations, risers installations or

installations with severe elevation changes.

Polybutene fluids are superior in that they resist

aging, have lower and more stable power factor

values and possess an inherent tackiness which

resists draining. Okonite treats the dielectric fluid

with clay-filtering and then de-gases it prior to

impregnating the cable to provide the lowest power

factor and ionization levels.

Sheath & JacketOkonite's copper bearing lead sheath provides an

impervious barrier from the environment; in

addition, it provides mechanical protection for the

insulation and encapsulation of the impregnant. All

lead sheaths have the inherent capacity for

substantial electrical conductivity, even under short

circuit conditions without requiring a separate

ground. Okonite's lead sheaths are applied with a

continuous lead extruder under the control of a

thickness gauge for uniform wall thickness and

concentricity of extrusion.

The Okolene jacket provides mechanical and

corrosion protection for the lead sheath and is

used in most installations. (Indoor and aerial

installations may not require a jacket). Okolene is a

thermoplastic polyethylene material that resists

most chemicals and moisture; it is unaffected by

oils below 60°C and has a low coefficient of friction

which aids pulling through ducts and conduits.

ApplicationsOkonite Paper Insulated Lead Covered 3/C cable

is recommended for use in underground ducts,

direct buried, and aerially when lashed to a

messenger.

PILC cables are used in any circuit that requires

the highest reliability, the longest uninterrupted

service life, and where the greatest surge,

impulse and AC dielectric strength is desired. An

added advantage is that a 3/C PILC cable permits

the largest amount of power to be transmitted in

the smallest diameter space because of its unique

triangle shaped and nested design.

Although not shown as an insulation above 600

Volts in the National Electrical Code, it is readily

approved for use by local inspectors because of

its extensive safe use by utilities. Therefore, PlLC

cables can be used in industrial or commercial

applications with prior notification and approval by

the local inspector.

Also available in other voltage ratings.

SpecificationsOkonite PILC cables are available in accordance

with AEIC CS1-90 or AEIC CS1-12.

° Cables made per AEIC CS1-90 have

traditional nominal wall thicknesses

for the lead sheath and overall

jacket.

° Cables made per AEIC CS1-12 have

"minimum point" wall thicknesses for

the lead sheath and overall jacket.

Specifications• Copper conductors available as:

° Concentric Round

° Compact Round

° Compact Sector (Pre-twisted)

• 90°C continuous operation.

• 110°C emergency rating.

• 200°C short circuit rating.

• Polybutene impregnating fluid.

• Type H (shielded) cable.

• High impulse strength.

• Proven service life of over 80 years.

• Impervious to environment.

• Copper bearing lead sheath.

Options• Available in other voltage ranges from 0.6

though 69 kV.

• Available with 133 and 173% insulation levels.

• Available as 3 and 4 conductor cables.

• Available with high viscosity dielectric fluid for

risers and installations with severe elevation

differences.

• Available with a reinforced lead sheath (ROC-

Reinforced Okonite Covering).

• Available with LS/ZH Okoclear TP (TPPO) and

Okoseal (PVC) jackets.

• Belted PILC cables are also available.

Solid Type PILC15kV Paper Insulated Lead Covered Power CableThree Copper Conductor/90°C Rating100% Insulation Level

AEIC CS1-90 11th Edition(A)

Product DataSection 2: Sheet 31

THE OKONITE COMPANYRamsey, New Jersey 07446

A-Lead sheath and jacket thicknesses per AEIC CS1-90 version using traditional nominal thicknesses.

AEIC CS1-12 12th Edition(B)

Authorized Stock Item. Stock items use

high viscosity polybutene impregnating fluid.

Available from our Customer Service Centers.

(1) Ampacity for one circuit, one conduit in

ductbank, 90°C conductor temperature, 90

RHO soil 20°C earth temperature, 100% Load

Factor, multi point grounded sheaths. Per Okonite Bulletin 205,

page 53.

(2) Ampacity for one circuit, one conduit in

ductbank, 90°C conductor temperature, 90

RHO soil 20°C earth temperature, 75% Load

Factor, multi point grounded sheaths. Per Okonite Bulletin 205,

page 53.

B- Lead sheath and jacket thicknesses per AEIC CS1-12 version using minimum point thicknesses.

Catalo

gNum

ber

Conduct

or size

AWG

/kcm

il

Conduct

or Size

-mm

²

Insu

latio

nThic

knes

s

Nom

inal

-mils

Cab

leDia

met

er-in

ches

Am

paciti

es D

uct (1

)

(100

%LF)

Am

paciti

esin

Duct

(2)

(75%

LF)

Lead

Thickn

ess

Nom

inal

-mils

Jack

et T

hickn

ess

Nom

inal

-mils

New

Wei

ght - Ib

s./ft

.

Concentric Round

101-63-4120101-63-4175

2 33.61 42.4

180165

9090

9090

1.921.94

4.344.53

146 154167 176

Compact Round

101-63-4243 1/0 53.5 165 90 90 1.97 4.83 191 202

Compact Sector

101-63-4277101-63-4335101-63-4373101-63-4436

▲101-63-4544▲101-63-4665

101-63-4904

2/0 67.43/0 85.04/0 107.0250 127.0350 177.0500 253.0750 380.0

165165165165165165165

9090909090

110110

9090909090

110110

1.922.002.122.192.372.642.94

4.805.326.136.678.19

10.3713.71

215 228245 260280 297307 327371 397450 483555 599

Catalo

g Num

ber

Conduct

or siz

e

AWG

/kcm

il

Conduct

or Siz

e -m

Insu

latio

n Thic

knes

s

Nom

inal

-mils

Cab

le D

iam

eter

-inch

es

Am

paciti

es D

uct (1

)

(100

% L

F)

Am

paciti

es in

Duct

(2)

(75%

LF)

Lead T

hickn

ess

Nom

inal

-mils

Jack

et T

hickn

ess

Nom

inal

-mils

New

Wei

ght - Ib

s./ft

.

Concentric Round

101-61-4120101-61-4175

2 33.61 42.4

180165

8585

7070

1.931.95

4.464.65

146 154167 176

Compact Round

101-61-4243 1/0 53.5 165 85 70 1.98 4.96 191 202

Compact Sector

101-61-4277101-61-4335101-61-4373101-61-4436101-61-4544101-61-4665101-61-4904101-61-4986

2/0 67.43/0 85.04/0 107.0250 127.0350 177.0500 253.0750 380.0

1000 507.0

165165165165165165165165

8585858585

100100100

70707070708585

100

1.932.022.122.202.372.652.953.29

4.925.456.116.658.00

10.6113.7316.95

215 228245 260280 297307 327371 397450 483555 599636 689

G/21060231

Okoguard URO-J®

15kV Underground Primary Distribution Cable-JacketedRed Identification StripesAluminum Conductor/105°C Rating100% and 133% Insulation Levels

A Conductor-Stranded AluminumStrand Screen-BExtruded Semiconducting EPR

C Insulation-Okoguard-EPRD Insulation Screen-

Extruded Semiconducting EPRE Concentric Conductor-Bare

Copper WiresEncapsulating Jacket-OkoleneFwith 3 extruded red ID stripesand NESC lightning bolt

Product DataSection 2: Sheet 35

1/0

AW

G O

KO

GU

AR

D E

PR

100%

IN

SU

L

� ◄

InsulationOkoguard is Okonite's registered tradename for its exclusive ethylene-propylenerubber (EPR) based, thermosettingcompound, whose optimum balance ofelectrical and physical properties isunequaled in other solid dielectrics.Okoguard insulation, with the distinctive redcolor and a totally integrated EPR system,provides the optimum balance of electricaland physical properties for long, problemfree service.The triple tandem extrusion of the screenswith the insulation provides optimumelectrical characteristics.An insulation screen of ethylene-propylenerubber is extruded over the insulation. Thebare copper concentric wires are uniformlyspaced around the insulation screen. Theoverall polyethylene jacket providesprotection against mechanical damage andcorrosion.Product identification is provided throughthe use of three red stripes placed 120°apart in the black jacket with an NESClightning bolt.

ApplicationsOkoguard URO-J cables provide maximumcircuit longevity in underground residentialdistribution systems. They can be burieddirectly or installed in underground ducts orconduits.

SpecificationsCentral Conductor: Aluminum per ASTMB-609, Class B stranded per B-231.Conductor Screen: Extrudedsemiconducting ethylene-propylene rubbermeets or exceeds the requirements of ICEAS-94-649, AEIC CS8, and CSA C68.5.Insulation: Extruded Okoguard meets orexceeds the requirements of ICEA S-94-649, AEIC CS8, and CSA C68.5.Insulation Screen: Extrudedsemiconducting ethylene-propylene rubbermeets or exceeds the requirements of ICEAS-94-649, AEIC CS8, and C68.5.Concentric Conductor: Bare copper wires.

Jacket: Black Okolene with redextruded stripes meets or exceeds therequirements of ICEA S-94-649, AEICCS8, and CSA C68.5 for polyethylenejackets.

Product Features• Triple tandem extruded, all EPRsystem• Okoguard cables meet or exceedICEA standards.• Meets RUS 1728.204 for cables withfilled strand or solid conductor and133% insulation level.• 105°C continuous operatingtemperature.

140°C emergency rating.•250°C short circuit rating.•

• Excellent corona resistance.• Low dielectric constant and powerfactor.• Screens are clean stripping.• Exceptional resistance to "treeing".• Moisture resistant.• Overall jacket provides extended life.• Red extruded stripes.• Excellent resistance to mostchemicals.• Can be listed by UL as Type MV-90on Special Orders.• CSA C68.5 listed, LTGG (-40 C), SR.�

• Design Options:Additional conductor sizesFilled strandCopper central conductorCopper flat strap concentric neutralProduct identification via coloredjackets.Semiconducting jacket

• Improved Temperature Rating.Okoguard insulation system has beentested and qualified for operation at105°C continuous and 140°Cemergency operating temperature.• Minimum installation temperature of-40°C.

Okonite’s web site, www.okonite.com contains the most up to date information.

Okoguard URO-J15kV Underground Primary Distribution Cable-JacketedRed Identification StripesAluminum Conductor/105°C Rating100% Insulation Level

Okoguard Insulation: 175 mils 100% Insulation Level

Product DataSection 2: Sheet 35

Catalo

gNum

ber

Conduct

or si

ze

(AW

G o

r kc

mil)

Appro

x. N

et W

eight

lbs.

/100

0’

Appro

x. S

hip W

eight

lbs.

/100

0’

THE OKONITE COMPANYRamsey, New Jersey 07446

Nom

inal

Dia

. ove

r Insu

latio

n (in.)

Nom

inal

Dia

. ove

r Insu

latio

n

Scree

n (in.)

Copper

Neu

tral

, No. x

AWG

(1)

Nom

inal

O.D

. (in

.)

90C

Am

pacity

Dire

ct B

urial (

2)

°90

CAm

pacity

Duct

(2)

°10

5C

Am

pacity

Dire

ct B

urial (

2)

°10

5C

Am

pacity

Duct

(2)

°

(1) Individual wire size and count may vary. The resulting combination meets the 1/3 or full neutral,size requirement.

Ampacities

(2) Full neutral, single phase ampacities are based on ICEA P-117-734for 90°C or 105°C conductor temperature, 25°C ambient temperature,100% load factor, and earth thermal resistivity of RHO 90.One third neutral ampacities are based on triplexed or triangularconfiguration for the same conditions stated above.

Insu

latio

n Scr

een

Thickn

ess

(mils

)

FULL NEUTRAL

161-23-2057161-23-2060161-23-2066161-23-2069

2(1X)2(7X)

1(19X)1/0(1X)

0.66 30 0.730.67 30 0.750.72 30 0.790.72 30 0.80

10X1410X1413X1416X14

0.970.981.031.03

499 603512 568587 698642 747

170 125170 125195 145220 160

185 135185 135210 155235 175

161-23-2072161-23-2075161-23-2078

1/0(19X)2/0(19X)3/0(19X)

0.75 30 0.830.80 30 0.870.85 30 0.92

16X1414X1216X12

1.061.141.19

662 725791 910

908 1029

220 160250 185285 210

235 175270 205310 230

161-23-2081161-23-2084161-23-2090

4/0(19X)250(37X)350(37X)

0.90 30 0.980.97 30 1.041.07 40 1.17

14X1016X10

18X.1078

1.291.361.50

1129 12381268 14181598 1793

320 240350 270425 310

350 260380 295460 340

1/3 NEUTRAL

160-23-2057160-23-2060160-23-2066160-23-2069

2(1X)2(7X)

1(19X)1/0(1X)

0.66 30 0.730.67 30 0.750.72 30 0.790.72 30 0.80

6X146X146X146X14

0.970.981.031.03

452 528465 579505 617525 663

150 120150 120175 140195 155

165 135165 135185 150215 170

160-23-2072160-23-2075160-23-2078160-23-2081

1/0(19X)2/0(19X)3/0(19X)4/0(19X)

0.74 30 0.830.80 30 0.870.85 30 0.920.90 30 0.98

6X147X149X1411X14

1.061.111.161.21

545 662611 726695 889792 922

195 155225 180255 200285 235

215 170240 195275 220310 255

160-23-2084160-23-2090160-23-2093

250(37X)350(37X)500(37X)

0.97 30 1.041.07 40 1.171.20 40 1.30

13X1418X1416X12

1.281.411.57

892 10181135 13151470 1691

305 250375 310450 370

330 275405 335490 405

160-23-2096160-23-2099

750(61X)1000(61X)

1.39 40 1.491.54 40 1.64

16X.096618X.1052

1.862.03

2062 24022580 2877

545 460620 520

595 505675 570

Okonite’s web site, www.okonite.com contains the most up to date information.

Okoguard URO-J15kV Underground Primary Distribution Cable-JacketedRed Identification StripesAluminum Conductor/105°C Rating133% Insulation Levels

Okoguard Insulation: 220 mils 133% Insulation Level

Product DataSection 2: Sheet 35

O/20110235

THE OKONITE COMPANYRamsey, New Jersey 07446

▲Authorized stock item. Available from our Customer ServiceCenters.

Ampacities

(2) Full neutral, single phase ampacities are based on ICEAP-117-734 for 90°C or 105°C conductor temperature, 25°C ambienttemperature, 100% load factor, and earth thermal resistivity of RHO90.One third neutral ampacities are based on triplexed or triangularconfiguration for the same conditions stated above.

Catalo

gNum

ber

Conduct

or si

ze

(AW

G o

r kc

mil)

Appro

x. N

et W

eight

lbs.

/100

0’

Appro

x. S

hip W

eight

lbs.

/100

0’

Nom

inal

Dia

. ove

r Insu

latio

n (in.)

Nom

inal

Dia

. ove

r Insu

latio

n

Scree

n (in.)

Copper

Neu

tral

, No. x

AWG

(1)

Nom

inal

O.D

. (in

.)

90C

Am

pacity

Dire

ct B

urial (

2)

°90

CAm

pacity

Duct

(2)

°10

5C

Am

pacity

Dire

ct B

urial (

2)

°10

5C

Am

pacity

Duct

(2)

°In

sula

tion S

cree

n

Thickn

ess

(mils

)

FULL NEUTRAL

▲161-23-3057161-23-3060161-23-3066

▲161-23-3069

2(1X)2(7X)

1(19X)1/0(1X)

0.74 30 0.820.77 30 0.840.81 30 0.880.80 30 0.89

10X1410X1413X1416X14

1.061.081.121.12

572 635590 662669 781721 792

170 125170 125195 145220 160

185 135185 135210 155235 175

▲161-23-9525161-23-3072161-23-3075161-23-3078

1/0(1X)1/0(19X)2/0(19X)3/0(19X)

0.80 30 0.890.84 30 0.920.89 30 0.920.94 30 1.01

10X14*16X1414X1216X12

1.121.151.231.28

651 718746 818900 1012998 1136

230 170220 160250 185285 210

245 185235 175270 205310 230

161-23-3081161-23-3084161-23-3090

4/0(19X)250(37X)350(37X)

0.98 30 1.061.06 40 1.161.16 40 1.26

14X1016X10

18X.1078

1.381.471.59

1226 13571405 16191716 1912

320 240350 270425 310

350 260380 295460 340

1/3 NEUTRAL

160-23-3057160-23-3060160-23-3066160-23-3069

2(1X)2(7X)

1(19X)1/0(1X)

0.74 30 0.820.76 30 0.840.81 30 0.880.80 30 0.89

6X146X146X146X14

1.061.081.121.12

525 621543 659586 700604 715

150 120150 120175 140195 155

165 135165 135185 150215 170

160-23-3072160-23-3075160-23-3078160-23-3081

1/0(19X)2/0(19X)3/0(19X)4/0(19X)

0.84 30 0.920.89 30 0.960.94 30 1.010.99 30 1.06

6X147X149X1411X14

1.151.201.251.30

629 748699 826787 916884 1002

195 155225 180255 200285 235

215 170240 195275 220310 255

160-23-3084160-23-3090160-23-3093

250(37X)350(37X)500(37X)

1.06 40 1.161.16 40 1.261.29 40 1.39

13X1418X1416X12

1.401.501.72

1024 11681243 14581650 1959

305 250375 310450 370

330 275405 335490 405

160-23-3096160-23-3099

**▲160-23-9590

750(61X)1000(61X)1100(61X)

1.47 40 1.581.64 55 1.771.61 55 1.74

16X.096618X.105218X12**

1.952.162.01

2201 25182802 32232470 2833

545 460620 520675 575

595 505675 570730 620

* - Special design 64% neutral** - Special design 1/6 neutral, compact conductor(1) Individual wire size and count may vary. The resulting combination meets the 1/3 or full neutral,size requirement.

Okoguard URO-J®

15kV Underground Primary Distribution Cable-JacketedRed Identification StripesFilled Strand Aluminum Conductor/105°C Rating100% and 133% Insulation Levels

A Conductor-Stranded Aluminumwith Filled StrandStrand Screen - ExtrudedBSemiconducting EPR

C Insulation-Okoguard EPRD Insulation Screen - Extruded

Semiconducting EPRE Concentric Conductor-Bare

Copper WiresEncapsulating Jacket-OkoleneFwith Extruded ID Stripes & NESClightning bolt

Product DataSection 2: Sheet 36

InsulationOkoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound, whoseoptimum balance of electrical and physicalproperties is unequaled in other soliddielectrics. Okoguard insulation, with thedistinctive red color and a totally integratedEPR system, provides the optimum balance ofelectrical and physical properties for long,problem free service.

The triple tandem extrusion of the screens withthe insulation provides optimum electricalcharacteristics.

The compressed conductors are filled with awater swellable agent. This construction slowsthe migration of water through the strands inthe event of a mechanical dig-in followed byexternal exposure to water.

An insulation screen of ethylene-propylenerubber is extruded over the insulation. Thecopper concentric wires are uniformly spacedaround the insulation screen. The overallpolyethylene jacket provides protection againstmechanical damage and corrosion.

Product identification is provided through theuse of three red stripes placed 120° apart in theblack jacket, with an NESC lightning bolt.

ApplicationsOkoguard URO-J cables provide maximumcircuit longevity in underground residentialdistribution systems. They can be burieddirectly or installed in underground ducts orconduits.

SpecificationsCentral Conductor: Aluminum per ASTM

B-609, Class B stranded per B-231.

Filled Strand: Water swellable agent meets orexceeds ICEA T-31-610 water penetrationresistance and ANSI/NEMA class Aconnectorability requirements.

Conductor Screen: Extruded semiconuctingethylene-propylene rubber meets or exceedsthe requirements of ICEA S-94-649, AEIC CS8,and CSA C68.5.

Insulation: Extruded Okoguard meets orexceeds the requirements of ICEA S-94-649,AEIC CS8, and C68.5.

Insulation Screen: Extruded semiconductingethylene-propylene rubber meets or exceedsthe requirements of ICEA S-94-649, AEIC CS8,and CSA C68.5.

Concentric Conductor: Bare copper wires.

Jacket: Black Okolene with red extrudedstripes meets or exceeds the requirementsof ICEA S-94-649, AEIC CS8, and CSAC68.5 for polyethylene jackets.

Product Features• Triple tandem extruded, all EPR system.

• Okoguard cables meet or exceed ICEA

standards.

• Meets RUS 1728.204 for cables with filledstrand or solid conductor and 133%insulation level.

• 105°C continuous operating temperature.140°C emergency rating.•250°C short circuit rating.•

• Excellent corona resistance.

• Low dielectric constant and power factor.

• Screens are clean stripping.

• Exceptional resistance to "treeing".

• Filled strand conductor.

• Moisture resistant.• Overall jacket provides extended life.

• Excellent resistance to most chemicals.

• Can be listed by UL as Type MV-90 onSpecial Orders.

• CSA C68.5 listed, LTGG (-40°C), SR.

• Design Options:

Additional conductor sizes

Copper central conductor

Copper flat strap concentric neutral

Product identification via colored jackets.

Semiconducting jackets.

• Improved Temperature Rating.

Okoguard insulation system has beentested and qualified for operation at 105°Ccontinuous and 140°C emergency operatingtemperature.

• Minimum installation temperature of

-40°C.1/0

AW

G O

KO

GU

AR

D E

PR

100%

IN

SU

L

� ◄

Okonite’s web site, www.okonite.com contains the most up to date information.

Okoguard URO-J15kV Underground Primary Distribution Cable-JacketedRed Identification StripesFilled Strand Aluminum Conductor/105°C Rating100% Insulation Level

Okoguard Insulation: 175 mils 100% Insulation Level

Product DataSection 2: Sheet 36

THE OKONITE COMPANYRamsey, New Jersey 07446

(1) Individual wire size and count may vary. The resulting combination meets the 1/3 or full neutral,size requirement.

▲ . Available from our Customer ServiceAuthorized stock itemCenters.

Ampacities

(2) Full neutral, single phase ampacities are based on ICEAP-117-734 for 90°C or 105°C conductor temperature, 25°Cambient temperature, 100% load factor, and earth thermal resistivityof RHO 90.One third neutral ampacities are based on triplexed or triangularconfiguration for the same conditions stated above.

Catalo

gNum

ber

Conduct

or si

ze

(AW

G o

r kc

mil)

Appro

x. N

et W

eight

lbs.

/100

0’

Appro

x. S

hip W

eight

lbs.

/100

0’

Nom

inal

Dia

. ove

r Insu

latio

n (in.)

Nom

inal

Dia

. ove

r Insu

latio

n

Scree

n (in.)

Copper

Neu

tral

, No. x

AWG

(1)

Nom

inal

O.D

. (in

.)

90C

Am

pacity

Dire

ct B

urial (

2)

°90

CAm

pacity

Duct

(2)

°10

5C

Am

pacity

Dire

ct B

urial (

2)

°10

5C

Am

pacity

Duct

(2)

°In

sula

tion S

cree

n

Thickn

ess

(mils

)

FULL NEUTRAL

▲163-23-2060163-23-2066

▲163-23-2072163-23-2075

2(7X)1(19X)

1/0(19X)2/0(19X)

0.68 30 0.750.72 30 0.790.76 30 0.830.80 30 0.87

10X1413X1416X1414X12

0.991.031.071.14

517 626588 698667 778793 910

170 125195 145220 160250 185

185 135210 155235 175270 205

163-23-2078163-23-2081163-23-2084163-23-2090

3/0(19X)4/0(19X)

250(37X)350(37X)

0.85 30 0.920.90 30 0.980.97 30 1.041.07 40 1.17

16X1214X1016X10

18X.1078

1.191.291.351.50

910 10291131 12381270 14181603 1793

285 210320 240350 270425 310

310 230350 260380 295460 340

1/3 NEUTRAL

162-23-2060162-23-2066162-23-2072

2(7X)1(19X)

1/0(19X)

0.69 30 0.760.72 30 0.790.76 30 0.83

6X146X146X14

1.001.031.07

475 579506 617550 662

150 120175 140195 155

165 135185 150215 170

162-23-2075162-23-2078162-23-2081162-23-2084

2/0(19X)3/0(19X)4/0(19X)

250(37X)

0.80 30 0.870.85 30 0.920.90 30 0.980.97 30 1.04

7X149X1411X1413X14

1.111.161.211.28

612 726697 889794 922895 1018

225 180255 200285 235305 250

240 195275 220310 255330 275

162-23-2090162-23-2093162-23-2096162-23-2099

350(37X)500(37X)750(37X)

1000(61X)

1.07 40 1.171.20 40 1.301.39 40 1.491.54 40 1.68

18X1416X12

16X.096618X.1052

1.411.571.862.06

1138 13151476 16912066 24022645 3059

375 310450 370545 460620 520

405 335490 405595 505675 570

Okonite’s web site, www.okonite.com contains the most up to date information.

Okoguard URO-J15kV Underground Primary Distribution Cable-JacketedRed Identification StripesFilled Strand Aluminum Conductor/105°C Rating133% Insulation Levels

Okoguard Insulation: 220 mils 133% Insulation Level

Product DataSection 2: Sheet 36

P/21010236

THE OKONITE COMPANYRamsey, New Jersey 07446

(1) Individual wire size and count may vary. The resulting combination meets the 1/3 or full neutral, size requirement.

▲ - Available from Customer ServiceAuthorized Stock Itemcenters.

Ampacities

(2) Full neutral, single phase ampacities are based on ICEA P-117-734 for 90°C or 105°C conductor temperature, 25°Cambient temperature, 100% load factor, and earth thermalresistivity of RHO 90.One third neutral ampacities are based on triplexed ortriangular configuration for the same conditions stated above.

Catalo

gNum

ber

Conduct

or si

ze

(AW

G o

r kc

mil)

Appro

x. N

et W

eight

lbs.

/100

0’

Appro

x. S

hip W

eight

lbs.

/100

0’

Nom

inal

Dia

. ove

r Insu

latio

n (in.)

Nom

inal

Dia

. ove

r Insu

latio

n

Scree

n (in.)

Copper

Neu

tral

, No. x

AWG

(1)

Nom

inal

O.D

. (in

.)

90C

Am

pacity

Dire

ct B

urial (

2)

°90

CAm

pacity

Duct

(2)

°10

5C

Am

pacity

Dire

ct B

urial (

2)

°10

5C

Am

pacity

Duct

(2)

°In

sula

tion S

cree

n

Thickn

ess

(mils

)

FULL NEUTRAL

▲163-23-3060163-23-3066

▲163-23-3072163-23-3075

2(7X)1(19X)

1/0(19X)2/0(19X)

0.77 30 0.840.81 30 0.880.84 30 0.920.89 30 0.96

10X1413X1416X1414X12

1.081.121.151.23

591 669670 766748 820902 996

170 125195 145220 160250 185

185 135210 155235 175270 205

163-23-3078163-23-3081163-23-3084163-23-3090

3/0(19X)4/0(19X)

250(37X)350(37X)

0.94 30 1.010.98 30 1.061.06 40 1.161.16 40 1.26

16X1214X1016X10

18X.1078

1.281.381.471.59

1004 11251228 13471410 16061721 1912

285 210320 240350 270425 310

310 230350 260380 295460 340

1/3 NEUTRAL

162-23-3060162-23-3066162-23-3072162-23-3075

2(7X)1(19X)

1/0(19X)2/0(19X)

0.77 30 0.840.81 30 0.880.84 30 0.920.89 30 0.96

6X146X146X147X14

1.081.121.151.20

544 627588 684631 733701 810

150 120175 140195 155225 180

165 135185 150215 170240 195

162-23-3078▲162-23-3081

162-23-3084▲162-23-3090

3/0(19X)4/0(19X)

250(37X)350(37X)

0.94 30 1.010.98 30 1.061.06 40 1.161.16 40 1.26

9X1411X1413X1418X14

1.251.301.401.50

789 905887 1005

1029 11641246 1425

255 200285 235305 250375 310

275 220310 255330 275405 335

▲162-23-3093▲162-23-3096▲162-23-3099

500(37X)750(61X)

1000(37X)

1.29 40 1.391.47 40 1.581.64 55 1.77

16X1216X.096618X.1052

1.721.952.16

1653 18532209 24682807 3093

450 370545 460620 520

490 405595 505675 570

Okoguard URO-J®

25kV Underground Primary Distribution Cable-JacketedRed Identification StripesAluminum Conductor/105°C Rating100% and 133% Insulation Levels

A Conductor-Stranded AluminumStrand Screen - ExtrudedBSemiconducting EPR

C Insulation-Okoguard EPRD Insulation Screen - Extruded

Semiconducting EPRE Concentric Conductor-Bare

Copper WiresEncapsulating Jacket-OkoleneFwith three extruded red ID Stripes, andNESC lightning bolt

Product DataSection 2: Sheet 39

InsulationOkoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in other soliddielectrics. Okoguard insulation, with thedistinctive red color and a totally integratedEPR system, provides the optimum balance ofelectrical and physical properties for long,problem free service.

The triple tandem extrusion of the screens withthe insulation provides optimum electricalcharacteristics.

An insulation screen of ethylene-propylenerubber is extruded over the insulation. Thebare copper concentric wires are uniformlyspaced around the insulation screen. Theoverall polyethylene jacket provides protectionagainst mechanical damage and corrosion.

Product identification is provided through theuse of three red stripes placed 120° apart inthe black jacket with an NESC lightning bolt.

ApplicationsOkoguard URO-J cables provide maximumcircuit longevity in underground residentialdistribution systems. They can be burieddirectly or installed in underground ducts orconduits.

SpecificationsCentral Conductor: Aluminum per ASTM B-609, Class B stranded per B-231.

Conductor Screen: Extruded semiconductingethylene-propylene rubber meets or exceedsthe requirements of ICEA S-94-649, AEICCS8, and CSA C68.5.

Insulation: Extruded Okoguard meets orexceeds the requirements of ICEA S-94-649,AEIC CS8, and CSA C68.5.

Insulation Screen: Extruded semiconductingethylene-propylene rubber meets or exceedsthe requirements of ICEA S-94-649, AEICCS8, and CSA C68.5.

Concentric Conductor: Bare copper wires.

Jacket: Black Okolene with red extrudedstripes meets or exceeds the requirements ofICEA S-94-649, AEIC CS8, and CSA C68.5 forpolyethylene jackets.

Product Features• Triple tandem extruded, all EPR system.

• Okoguard cables meet or exceed ICEAstandards.

• Meets RUS 1728.204 for cables withfilled strand or solid conductor and 100%insulation level.

• 105°C continuous operating temperature.140°C emergency rating.•250°C short circuit rating.•

• Excellent corona resistance.

• Low dielectric constant and powerfactor.

• Screens are clean stripping.

• Exceptional resistance to "treeing".

• Moisture resistant.

• Overall jacket provides extended life.

• Red extruded stripes.

• Excellent resistance to most chemicals.

• Can be listed by UL as Type MV-90 onSpecial Orders.

• CSAC68.5 listed, LTGG (-40°C), SR.

• Design Options:

Additional conductor sizes

Filled strand

Copper central conductor

Copper flat strap concentric neutral

Product identification via colored jackets

Semiconducting jackets

• Improved Temperature Rating.

Okoguard insulation system has beentested and qualified for operation at 105°Ccontinuous and 140°C emergencyoperating temperature.

• Minimum installation temperature of

-40°C.

1/0

AW

G O

KO

GU

AR

D E

PR

100%

IN

SU

L

� ◄

Okonite’s web site, www.okonite.com contains the most up to date information.

Okoguard URO-J25kV Underground Primary Distribution Cable-JacketedRed Identification StripesAluminum Conductor/105°C Rating100% Insulation Levels

Okoguard Insulation: 260 mils 100% Insulation Level

Product DataSection 2: Sheet 39

* These items include filled strand

(1) Individual wire size and count may vary. The resulting combination meets the 1/3 or full neutral, size requirement.

▲ - Available from Customer ServiceAuthorized Stock ItemCenters.

Ampacities

(2) Full neutral, single phase ampacities are based on ICEA P-117-734for 90°C or 105°C conductor temperature, 25°C ambient temperature,100% load factor, and earth thermal resistivity of RHO 90.One third neutral ampacities are based on triplexed or triangularconfiguration for the same conditions stated above.

Catalo

gNum

ber

Conduct

or size

(AW

Gor kc

mil)

Appro

x. N

et W

eight

lbs.

/100

0’

Appro

x. S

hip W

eight

lbs.

/100

0’

Nom

inal

Dia

. ove

r Insu

latio

n (in.)

Nom

inal

Dia

. ove

r

Insu

latio

n Scr

een (i

n.)

Copper

Neu

tral

No. x

AWG

(1)

Nom

inal

O.D

. (in

.)

90C

Am

pacity

Dire

ct B

urial (

2)

°90

CAm

pacity

Duct

(2)

°In

sula

tion S

cree

n

Thickn

ess

(mils

)

FULL NEUTRAL

161-23-4066▲161-23-4069

161-23-4072▲163-23-4072*

161-23-4075

1(19X)1/0(1X)

1/0(19X)1/0(19X)2/0(19X)

0.89 30 0.960.89 30 0.970.93 30 1.000.92 30 1.000.97 30 1.05

13X1416X1416X1416X1414X12

1.201.201.241.231.32

747 872798 870832 898827 899986 1117

195 145220 160220 160220 160250 185

210 155235 175235 175235 175270 205

161-23-4078161-23-4081161-23-4084161-23-4090

3/0(19X)4/0(19X)

250(37X)350(37X)

1.02 30 1.011.08 40 1.181.14 40 1.241.25 40 1.35

16X1214X1016X10

18X.1078

1.371.491.551.74

1092 12101357 15501507 17241887 2166

285 210320 240350 270425 310

310 230350 260380 295460 340

1/3 NEUTRAL

160-23-4066160-23-4072160-23-4075160-23-4078

1(19X)1/0(19X)2/0(19X)3/0(19X)

0.88 30 0.960.93 30 1.000.97 30 1.051.02 30 1.01

6X146X147X149X14

1.191.241.281.33

659 791715 841784 912875 994

175 140195 155225 180255 200

185 150215 170240 195275 220

160-23-4081▲162-23-4081*

160-23-4084160-23-4090

4/0(19X)4/0(19X)

250(37X)350(37X)

1.08 40 1.181.07 40 1.171.14 40 1.241.24 40 1.34

11X1411X1413X1418X14

1.411.411.471.58

1011 11281006 11291115 13301347 1566

285 235285 235305 250375 310

310 255310 255330 275405 335

160-23-4093▲162-23-4093*

160-23-4096▲162-23-4096*

160-23-4099▲162-23-4099*

500(37X)500(37X)750(61X)750(61X)

1000(61X)1000(61X)

1.38 40 1.481.37 40 1.471.57 40 1.671.57 40 1.671.72 55 1.851.70 55 1.85

16X1216X12

16X.096616X.096618X.105218X.1052

1.811.802.032.032.242.23

1777 19861771 19882396 31562365 32152952 35332951 3535

450 370450 370545 460545 460620 520620 520

490 405490 405595 505595 505675 570675 570

105

CAm

pacity

Dire

ct B

urial (

2)

°

105

CAm

pacity

Duct

(2)

°

Okonite’s web site, www.okonite.com contains the most up to date information.

Okoguard URO-J25kV Underground Primary Distribution Cable-JacketedRed Identification StripesAluminum Conductor/105°C Rating133% Insulation Levels

Okoguard Insulation: 320 mils 133% Insulation Level

Product DataSection 2: Sheet 39

(1) Individual wire size and count may vary. The resulting combination meets the 1/3 or full neutral,size requirement.

Ampacities

(2) Full neutral, single phase ampacities are based on ICEA P-117-734 for 90°C or 105°C conductor temperature, 25°Cambient temperature, 100% load factor, and earth thermalresistivity of RHO 90.One third neutral ampacities are based on triplexed ortriangular configuration for the same conditions stated above.

THE OKONITE COMPANYRamsey, New Jersey 07446L/20110239

Catalo

gNum

ber

Conduct

or size

(AW

Gor kc

mil)

Appro

x. N

et W

eight

lbs.

/100

0’

Appro

x. S

hip W

eight

lbs.

/100

0’

Nom

inal

Dia

. ove

r Insu

latio

n (in.)

Nom

inal

Dia

. ove

r

Insu

latio

n Scr

een (i

n.)

Copper

Full

Neu

tral

No. x

AWG

(1)

Nom

inal

O.D

. (in

.)

90C

Am

pacity

Dire

ct B

urial (

2)

°90

CAm

pacity

Duct

(2)

°In

sula

tion S

cree

n

Thickn

ess

(mils

)

FULL NEUTRAL

161-23-5066161-23-5072161-23-5075

1(19X)1/0(19X)2/0(19X)

1.01 40 1.091.05 40 1.151.09 40 1.19

13X1416X1414X12

1.321.391.46

876 1047994 1138

1157 1353

195 145220 160250 185

210 155235 175270 205

161-23-5078161-23-5081161-23-5084161-23-5090

3/0(19X)4/0(19X)

250(37X)350(37X)

1.14 40 1.241.20 40 1.301.26 40 1.361.37 40 1.47

16X1214X1016X10

18X.1074

1.511.611.741.86

1269 25031514 18191733 20322068 2349

285 210320 240350 270425 310

310 230350 260380 295460 340

1/3 NEUTRAL

160-23-5066160-23-5072160-23-5075160-23-5078

1(19X)1/0(19X)2/0(19X)3/0(19X)

1.01 40 1.091.05 40 1.151.09 40 1.191.14 40 1.24

6X146X147X149X14

1.321.391.431.48

793 966877 1022952 1099

1049 1261

175 140195 155225 180255 200

185 150215 170240 195275 220

160-23-5081160-23-5084160-23-5090

4/0(19X)250(37X)350(37X)

1.20 40 1.301.26 40 1.361.37 40 1.47

11X1413X1418X14

1.541.601.77

1162 13781281 14901588 1881

285 235305 250375 310

310 255330 275405 335

160-23-5093160-23-5096160-23-5099

500(37X)750(61X)

1000(61X)

1.50 40 1.601.68 55 1.821.84 55 1.98

16X1216X.096618X.1052

1.932.202.36

1968 22752647 31223189 3771

450 370545 460620 520

490 405595 505675 570

Num

berof S

tran

ds

105

CAm

pacity

Dire

ct B

urial (

2)

°

105

CAm

pacity

Duct

(2)

°

InsulationOkoguard is Okonite's registered trade namefor its exclusive ethylene-propylene rubber(EPR) based, thermosetting compound,whose optimum balance of electrical andphysical properties is unequaled in othersolid dielectrics. Okoguard insulation, withthe distinctive red color and a totally inte-grated EPR system, provides the optimumbalance of electrical and physical propertiesfor long, problem free service.The triple tandem extrusion of the screenswith the insulation provides optimum electri-cal characteristics.An insulation screen of ethylene-propylenerubber is extruded over the insulation. Thebare copper concentric wires are uniformlyspaced around the insulation screen. Theoverall polyethylene jacket provides protec-tion against mechanical damage andcorrosion.Product identification is provided through theuse of three red stripes placed 120° apart inthe black jacket, with an NESC lightning bolt.

ApplicationsOkoguard URO-J cables provide maximumcircuit longevity in underground residentialdistribution systems. They can be buried di-rectly or installed in underground ducts orconduits.

SpecificationsCentral Conductor: Aluminum per ASTMB-609, Class B stranded per B-231.Conductor Screen: Extruded semiconduct-ing ethylene-propylene rubber meets orexceeds the requirements of ICEA S-94-649,AEIC CS8, and CSA C68.5.Insulation: Extruded Okoguard meets or ex-ceeds the requirements of ICEA S-94-649,AEIC CS8, and CSA C68.5.Insulation Screen: Extruded semiconduct-ing ethylene-propylene rubber meets orexceeds the requirements of ICEA S-94-649,AEIC CS8, and CSA C68.5.Concentric Conductor: Bare copper wires.Jacket: Black Okolene with red extrudedstripes meets or exceeds the requirements ofICEA S-94-649, AEIC CS8, and CSA C68.5for polyethylene jackets.

Product Features• Triple tandem extruded, all EPR system.

• Okoguard cables meet or exceed ICEAstandards.

• Meets RUS 1728.204 for cables withfilled strand or solid conductor and 100%insulation level.

• 105°C continuous operating temperature• 140°C emergency rating• 250°C short circuit rating

• Excellent corona resistance.

• Low dielectric constant and powerfactor.

• Screens are clean stripping.

• Exceptional resistance to “treeing”.

• Moisture resistant.

• Overall jacket provides extended life.

• Excellent resistance to most chemicals.

• Can be listed by UL as Type MV-90 onSpecial Orders.

• CSA C68.5 listed, LTGG (-40°C), SR.

• Design Options:Additional conductor sizesFilled strandCopper central conductorCopper flat strap concentric neutralProduct identification via coloredjacketsSemiconducting jackets

• Improved Temperature Rating.Okoguard insulation system has beentested and qualified for operation at105°C continuous and 140°C emergencyoperating temperature. Appropriate jacketshould be selected when cable is to beoperated at these higher temperatures.

• Minimum installation temperature of-40°C.

Okoguard® URO-J35kV Underground Primary Distribution Cable-JacketedRed Identification StripesAluminum Conductor/105°C Rating100% and 133% Insulation Levels

Product DataSection 2: Sheet 40

A Conductor-Stranded AluminumB Strand Screen- Extruded

Semiconducting EPRC Insulation-Okoguard EPRD Insulation Screen- Extruded

Semiconducting EPRE Concentric Conductor-Bare Copper

WiresF Encapsulating Jacket-Okolene with

three extruded red ID stripes andNESC lightning bolt

Okoguard URO-J35kV Underground Primary Distribution Cable-JacketedRed Identification StripesAluminum Conductor/105°C Rating100% Insulation Level

Okoguard Insulation: 345 mils 100% Insulation Level

Product DataSection 2: Sheet 40

FULL NEUTRAL

161-23-6072� 163-23-6072*

161-23-6075161-23-6078

1/0 (19x)1/0 (19x)2/0 (19x)3/0 (19x)

1.10 401.10 401.15 401.20 40

1.201.201.251.30

16x1416x1414x1216x12

1.441.441.521.57

1055105712311336

1179118114161552

205205240270

165165190215

225225260295

180180205230

161-23-6081161-23-6084161-23-6090

4/0 (19x)250 (37x)350 (37x)

1.26 401.31 401.42 40

1.361.411.52

14x1016x10

18x.1078

1.741.791.91

165718052146

192121062525

310340410

240265320

335370445

265290350

1/3 NEUTRAL

160-23-6072160-23-6075160-23-6078

1/0 (19x)2/0 (19x)3/0 (19x)

1.10 401.15 401.20 40

1.201.251.30

6x147x149x14

1.441.481.54

93810151125

108212231326

195220250

160185210

210240270

175200230

160-23-6081160-23-6084160-23-6090

4/0 (19x)250 (37x)350 (37x)

1.26 401.31 401.42 40

1.361.411.52

11x1413x1418x14

1.601.721.82

124114111663

144517011957

285305370

235255315

310330405

260280345

160-23-6093160-23-6096160-23-6099

500 (37x)750 (61x)

1000 (61x)

1.55 401.74 551.89 55

1.651.882.03

16x1216x.096618x.1052

1.982.242.41

205827273289

251533233872

450545620

380470530

485595675

415515585

* These items include filled strand.

Okonite's web site, www.okonite.com contains the most up to date information.

CopperNeu

tral

Number

x AWG

(1)

Nomin

alDia.

Over

Insu

latio

n

Nomin

alDia.

Over

Insu

latio

nScr

een

Approx.

ShipW

eight

lbs./

1000

Conductor Size

AWG/kc

mil

105°

CAm

pacity

(2)

Direct

Burial

Catalo

gNum

ber

Nomin

alO.D

. (In

.)

Approx.

NetW

eight

lbs./

1000

105°

CAm

pacity

(2)

Duct90

°CAm

pacity

(2)

Direct

Burial

90°C

Ampac

ityDuct

(2)

� Authorized Stock Item - Available from Customer Servicecenters.

(1) Individual wire size and count may vary. The resulting combinationmeets the 1/3 or full neutral, size requirement.

Ampacities

(2) Full neutral, single phase ampacities are based on ICEA P-117-734for 90°C or 105°C conductor temperature, 25°C ambient temperature,100% load factor, and earth thermal resistivity of RHO 90.One third neutral ampacities are based on triplexed or triangular con-figuration for the same conditions stated above.

Insu

latio

nScr

een

Thicknes

s (mils

)

Okoguard URO-J35kV Underground Primary Distribution Cable-JacketedRed Identification StripesAluminum Conductor/105°C Rating133% Insulation Level

Okoguard Insulation: 420 mils 133% Insulation Level

Product DataSection 2: Sheet 40

FULL NEUTRAL

161-23-7072161-23-7075161-23-7078

1/0 (19x)2/0 (19x)3/0 (19x)

1.26 401.31 401.35 40

1.361.411.45

16x1414x1216x12

1.591.741.78

125015031608

146317701916

205240270

165190215

225260295

180205230

161-23-7081161-23-7084161-23-7090

4/0 (19x)250 (37x)350 (37x)

1.41 401.47 401.57 55

1.511.571.71

14x1016x10

18x.1078

1.891.952.10

189120482479

215923522846

310340410

240265320

335370445

265290350

1/3 NEUTRAL

160-23-7072160-23-7075160-23-7078

1/0 (19x)2/0 (19x)3/0 (19x)

1.26 401.31 401.36 40

1.361.411.46

6x147x149x14

1.591.711.76

113312921401

134715731684

195220250

160185210

210240270

175200230

160-23-7081160-23-7084160-23-7090

4/0 (19x)250 (37x)350 (37x)

1.40 401.47 401.56 55

1.501.571.70

11x1413x1418x14

1.801.872.00

150916461956

181419392367

285305370

235255315

310330405

260280345

160-23-7093160-23-7096160-23-7099

500 (37x)750 (61x)

1000 (61x)

1.69 551.90 552.05 55

1.832.032.18

16x1216x.096618x.1052

2.162.402.57

237030323617

284636324202

450545620

380470530

485595675

415515585

Okonite's web site, www.okonite.com contains the most up to date information.

CopperNeu

tral

Number

x AWG

(1)

Nomin

alDia.

Over

Insu

latio

n

Nomin

alDia.

Over

Insu

latio

nScr

een

Approx.

ShipW

eight

lbs./

1000

Conductor Size

AWG/kc

mil

105°

CAm

pacity

(2)

Direct

Burial

Catalo

gNum

ber

Number

of Strands

Approx.

NetW

eight

lbs./

1000

105°

CAm

pacity

Duct(2

)

Nomin

alO.D

. (In

.)

(1) Individual wire size and count may vary. The resulting combinationmeets the 1/3 or full neutral, size requirement.

Ampacities

(2) Full neutral, single phase ampacities are based on ICEA P-117-734for 90°C or 105°C conductor temperature, 25°C ambient temperature,100% load factor, and earth thermal resistivity of RHO 90.One third neutral ampacities are based on triplexed or triangular con-figuration for the same conditions stated above.

90°C

Ampac

ity(2

)

Direct

Burial

90°C

Ampac

ityDuct

(2)

J/19070240

THE OKONITE COMPANYRamsey, New Jersey 07446

Insu

latio

nScr

een

Thicknes

s (mils

)

Okoguard URO-J®

15kV to 35kV Underground Primary Distribution CableJacketed-Red Identification StripesCopper Conductor/105°C Rating100% and 133% Insulation Levels

A Conductor-Compressed or CompactRound CopperStrand Screen -BExtruded Semiconducting EPR

C Insulation-Okoguard-EPRD Insulation Screen -

Extruded Semiconducting EPRE Concentric Conductor-Bare Copper

WiresEncapsulating Jacket-Okolene withF3 extruded red ID stripes, and NESCLightning bolt

Product DataSection 2: Sheet 42

1/0

AW

G O

KO

GU

AR

D E

PR

100%

IN

SU

L

� ◄

InsulationOkoguard is Okonite's registered trade name

for its exclusive ethylene-propylene rubber

(EPR) based, thermosetting compound,

whose optimum balance of electrical and

physical properties is unequaled in other

solid dielectrics. Okoguard insulation, with

the distinctive red color and a totally

integrated EPR system, provides the

optimum balance of electrical and physical

properties for long, problem-free service.

The triple tandem extrusion of the screens

with the insulation provides optimum

electrical characteristics.

An insulation screen of ethylene-propylene

rubber is extruded over the insulation. The

bare concentric copper wires are uniformly

spaced around the insulation screen. The

overall polyethylene jacket provides

protection against mechanical damage and

corrosion.

Product identification is provided through the

use of three red stripes placed 120° apart in

the black jacket with an NESC Lightning bolt.

ApplicationsOkoguard URO-J cables provide maximum

circuit longevity in underground residential

distribution systems. They can be buried

direct or installed in underground ducts or

conduits.

SpecificationsCentral Conductor: Uncoated soft copper.

Compressed round conductors per ASTM

B-3 and ASTM B-8. Compact round

conductors per ASTM B-496.

Conductor Screen: Extruded

semiconducting ethylene-propylene rubber

meets or exceeds the requirements of ICEA

S-94-649, AEIC CS8, and CSA C68.5.

Insulation: Extruded Okoguard meets or®

exceeds the requirements of ICEA S-94-649,

AEIC CS8, and CSA C68.5.

Insulation Screen: Two insulation screen

thicknesses are available:

Cables with Compressed Round Copper

Conductor: Have extruded semiconducting

ethylene-propylene rubber insulation

screens that meet the requirements of ICEA

S-94-649, AEIC CS8, and CSA C68.5.

Select cables with Compact Round

Copper Conductor: Have extruded

semiconducting ethylene-propylene rubber

insulation screens that meet the

requirements of ICEA S-93-639/NEMA

WC74 & S-97-682, and AEIC CS8.

Concentric Conductor: Bare copper wires.

Jacket: Black Okolene with red extruded

stripes meets or exceeds the requirements

of ICEA S-94-649, AEIC CS8, and CSA

C68.5 for polyethylene jackets.

Product Features• Triple tandem extruded, all EPR

system

• Okoguard cables meet or exceed ICEA

standards.

• 105°C continuous operating

temperatures

140°C emergency rating•250°C short circuit rating•

• Excellent corona resistance.

• Low dielectric constant and power

factor.

• Screens are clean stripping.

• Exceptional resistance to "treeing".

• Moisture resistant.

• Excellent resistance to most

chemicals.

• Can be listed by UL as Type MV-90 on

Special Orders.

• CSA C68.5 listed, LTGG (-40°C), SR.

• Design Options:- Additional conductor sizes- Filled strand- Copper flat strap concentric

neutral- Product identification via colored

jackets.- Semiconducting jacket.

• Improved Temperature Rating.

Okoguard insulation system has been

tested and qualified for operation at 105°C

continuous and 140°C emergency

operating temperature.

Product DataSection 2: Sheet 42

Okoguard URO-J®

Copper Compressed Round Conductor/105ºC Rating(with ICEA S-94-649 Insulation Screen Thickness)

15kV - 175 mils (4.45mm), 100% Insulation LevelFull Neutral

141-23-2060141-23-2066141-23-2072

2(7x)1(19x)

1/0(19x)

0.68 30 0.750.72 30 0.790.76 30 0.83

16x14 0.9914x12 1.0616x12 1.10

725 775890 959

1017 1086

210 160235 180270 205

230 175260 200290 225

141-23-2075141-23-2078141-23-2081

2/0(19x)3/0(19x)4/0(19x)

0.80 30 0.870.85 30 0.920.90 30 0.98

14x10 1.1916x10 1.24

18x.1073 1.30

1273 13801468 16171763 1912

310 235350 265405 305

335 255380 290440 330

1/3 Neutral

140-23-2060140-23-2066140-23-2072

2(7x)1(19x)

1/0(19x)

0.68 30 0.750.72 30 0.790.76 30 0.83

6x14 0.997x14 1.039x14 1.07

608 658693 743805 874

195 160220 180250 200

210 175240 195275 220

140-23-2075140-23-2078140-23-2081

2/0(19x)3/0(19x)4/0(19x)

0.80 30 0.870.85 30 0.920.90 30 0.98

11x14 1.1114x14 1.1618x14 1.21

937 10061106 11831318 1413

285 230325 260365 300

310 250350 285395 325

140-23-2084140-23-2090140-23-2093

250(37x)350(37x)500(37x)

0.97 30 1.041.07 40 1.171.20 40 1.30

14x12 1.3118x12 1.44

18x.0953 1.60

1549 16832021 22072721 2959

395 325475 390555 455

430 355515 425610 500

140-23-2096140-23-2099

750(61x)1000(61x)

1.39 40 1.491.54 40 1.64

24x.1010 1.8724x.1167 2.05

3925 48625083 5502

650 545815 685

710 600885 750

15kV - 220 mils (5.59mm), 133% Insulation LevelFull Neutral

141-23-3060141-23-3066141-23-3072

2(7x)1(19x)

1/0(19x)

0.77 30 0.840.81 30 0.880.85 30 0.92

16x14 1.0814x12 1.1516x12 1.19

803 871973 1055

1103 1185

210 160235 180270 205

230 175260 200290 225

141-23-3075141-23-3078141-23-3081

2/0(19x)3/0(19x)4/0(19x)

0.89 30 0.960.94 30 1.010.99 30 1.07

14x10 1.2816x10 1.33

18x.1073 1.39

1362 14541561 16631864 1953

310 235350 265405 305

335 255380 290440 330

1/3 Neutral

140-23-3060140-23-3066140-23-3072

2(7x)1(19x)

1/0(19x)

0.77 30 0.840.81 30 0.880.85 30 0.92

6x14 1.087x14 1.129x14 1.16

686 755774 858890 972

195 160220 180250 200

210 175240 195275 220

140-23-3075140-23-3078140-23-3081

2/0(19x)3/0(19x)4/0(19x)

0.89 30 0.960.94 30 1.010.99 30 1.07

11x14 1.2014x14 1.2518x14 1.31

1025 11051198 12901414 1506

285 230325 260365 300

310 250350 285395 325

140-23-3084140-23-3090140-23-3093

250(37x)350(37x)500(37x)

1.06 40 1.161.16 40 1.261.29 40 1.39

14x12 1.4318x12 1.53

18x.0953 1.77

1683 17982130 22762953 3146

395 325475 390555 455

430 355515 425610 500

140-23-3096140-23-3099

750(61x)1000(61x)

1.49 40 1.591.64 55 1.77

24x.1010 1.9624x.1167 2.18

4071 43535306 5667

650 545815 685

710 600885 750

Catalo

gNum

ber

Approx. N

et Weig

ht

(lbs./1

000’)

Approx. S

hipW

eight

(lbs./1

000’)

Catalo

gNum

ber

Conductor S

ize

AWG

/kcm

il

Nomin

al Dia

. over

Insula

tion

(in.)

Insula

tion

Screen

Thickness

(mils

)

Nomin

al Dia

. over

Insula

tion

Screen

(in.)

Copper Neutra

l

No. xAW

G(1

)

Nomin

al O.D

. (in

.)

90ºCAm

pacity

Direct B

urial (

2)

90ºCAm

pacity

Duct (2)

105ºCAm

pacity

Direct B

urial (

2)

105ºCAm

pacity

Duct (2)

Okonite’s web site, www.okonite.com contains the most up to date information.

(1) individual wire size and count may vary. The resulting combination meets 1/3 or full neutral, size requirement.

Product DataSection 2: Sheet 42

Okoguard URO-J®

Copper Compressed Round Conductor/105ºC Rating(with ICEA S-94-649 Insulation Screen Thickness)

25kV - 260 mils (6.60mm), 100% Insulation LevelFull Neutral

141-23-4066141-23-4072141-23-4075141-23-4078141-23-4081

1(19x)1/0(19x)2/0(19x)3/0(19x)4/0(19x)

0.89 30 0.960.93 30 1.000.97 30 1.041.02 40 1.121.08 40 1.18

14x12 1.2316x12 1.2714x10 1.3616x10 1.43

18x.1073 1.50

1053 11651187 13051451 15691683 18351992 2139

235 180270 205310 235350 265405 305

260 200290 225335 255380 290440 330

1/3 Neutral

140-23-4066140-23-4072140-23-4075140-23-4078140-23-4081

1(19x)1/0(19x)2/0(19x)3/0(19x)4/0(19x)

0.89 30 0.960.93 30 1.000.97 30 1.051.02 30 1.101.08 40 1.18

7x14 1.209x14 1.24

11x14 1.2814x14 1.3318x14 1.41

853 921972 1083

1110 12261287 14331537 1654

220 180250 200285 230325 260365 300

240 195275 220310 250350 285395 325

140-23-4084140-23-4090140-23-4093140-23-4096140-23-4099

250(37x)350(37x)500(37x)750(61x)

1000(61x)

1.14 40 1.241.24 40 1.341.38 40 1.481.57 40 1.701.72 55 1.85

14x12 1.5118x12 1.61

18x.0953 1.8424x.1010 2.0824x.1167 2.26

1783 19652235 24233032 34084285 46225458 5817

395 325475 390555 455650 545815 685

430 355515 425610 500710 600885 750

35kV - 345 mils (8.76mm), 100% Insulation LevelFull Neutral

141-23-6072141-23-6075141-23-6078141-23-6081

1/0(19x)2/0(19x)3/0(19x)4/0(19x)

1.11 40 1.211.13 40 1.231.20 40 1.301.26 40 1.36

16x12 1.4814x10 1.5516x10 1.61

18x.1073 1.75

1424 15641678 18401909 20522293 2439

265 210305 235345 270395 305

285 230330 255375 295430 330

1/3 Neutral

140-23-6072140-23-6075140-23-6078140-23-6081

1/0(19x)2/0(19x)3/0(19x)4/0(19x)

1.11 40 1.211.15 40 1.251.20 40 1.301.26 40 1.36

9x14 1.4511x14 1.4914x14 1.5418x14 1.60

1205 13441351 14891537 16761767 1906

250 210280 235320 265360 300

270 230305 260345 290395 330

140-23-6084140-23-6090140-23-6093140-23-6096140-23-6099

250(37x)350(37x)500(37x)750(61x)

1000(61x)

1.31 40 1.411.42 40 1.521.55 40 1.651.74 55 1.881.89 55 2.03

14x12 1.7518x12 1.85

18x.0953 2.0124x.1010 2.2524x.1167 2.43

2076 22352556 27363320 37894598 51635797 6323

390 330470 400555 470650 560815 700

425 365510 435605 515710 620885 770

35kV - 420 mils (10.67mm), 133% Insulation LevelFull Neutral

141-23-7022141-23-7025141-23-7028141-23-7031

1/0(19x)2/0(19x)3/0(19x)4/0(19x)

1.27 40 1.371.31 40 1.411.36 40 1.461.41 40 1.51

16x12 1.6414x10 1.7916x10 1.84

18x.1073 1.90

1628 18321980 22262201 24472528 2778

265 210305 235345 270395 305

285 230330 260375 290430 330

1/3 Neutral

140-23-9923140-23-9931140-23-9932140-23-9940140-23-9941140-23-9942140-23-9943140-23-9944140-23-9946

1/0(19x)2/0(19x)3/0(19x)4/0(19x)

250(37x)350(37x)500(37x)750(61x)

1000(61x)

1.27 40 1.371.31 40 1.411.36 40 1.461.41 40 1.511.47 40 1.571.57 40 1.671.70 55 1.841.90 55 2.032.02 55 2.18

9x14 1.6011x14 1.7114x14 1.7618x14 1.8214x12 1.9018x12 2.00

18x.0953 2.2024x.1010 2.4124x.1167 2.59

1406 15941619 18231813 20172053 22582314 28772818 31823658 40274905 54646128 6699

250 210280 235320 265360 300390 330470 400555 470650 560815 700

270 230305 255345 295395 330425 365510 435605 515710 620885 770

Catalo

gNum

ber

Approx. N

et Weig

ht

(lbs./1

000’)

Approx. S

hipW

eight

(lbs./1

000’)

Catalo

gNum

ber

Conductor S

ize

AWG

/kcm

il

Nomin

al Dia

. over

Insula

tion

(in.)

Insula

tion

Screen

Thickness

(mils

)

Nomin

al Dia

. over

Insula

tion

Screen

(in.)

Copper Neutra

l

No. xAW

G(1

)

Nomin

al O.D

. (in

.)

90ºCAm

pacity

Direct B

urial (

2)

90ºCAm

pacity

Duct (2)

105ºCAm

pacity

Direct B

urial (

2)

105ºCAm

pacity

Duct (2)

Okonite’s web site, www.okonite.com contains the most up to date information.

(1) individual wire size and count may vary. The resulting combination meets 1/3 or full neutral, size requirement.

Product DataSection 2: Sheet 42

Okoguard URO-J®

Copper Compact Round Conductor/105ºC Rating(with ICEA S-94-649 Insulation Screen Thickness)**

15kV - 175 mils (4.45mm), 100% Insulation LevelFull Neutral

141-23-2010141-23-2012141-23-2014141-23-2018141-23-2020

●141-23-2024

2(7x)1(19x)

1/0(19x)2/0(19x)3/0(19x)4/0(19x)

0.67 30 0.740.70 30 0.770.74 30 0.810.78 30 0.850.83 30 0.900.86 24 0.93

16x14 0.9814x12 1.0416x12 1.0814x10 1.1716x10 1.21

18x.1073 1.26

718 762879 950

1004 10751256 13611449 15991723 1823

210 160235 180270 205310 235350 265405 305

230 175260 200290 225335 255380 290440 330

1/3 Neutral

140-23-2010140-23-2012140-23-2014140-23-2018140-23-2020

●140-23-2024140-23-2026

●140-23-2030●140-23-2032●140-23-2036

140-23-2038

2(7x)1(19x)

1/0(19x)2/0(19x)3/0(19x)4/0(19x)

250(37x)350(37x)500(37x)750(61x)

1000(61x)

0.67 30 0.740.70 30 0.770.74 30 0.810.78 30 0.850.83 30 0.900.86 24 0.930.93 30 1.011.01 24 1.081.12 24 1.191.30 24 1.371.47 40 1.57

6x14 0.987x14 1.019x14 1.05

11x14 1.0914x14 1.1418x14 1.1714x12 1.2818x12 1.35

18x.0953 1.4924x.1010 1.7424x.1167 1.98

601 645682 732792 864922 990

1089 11571280 13611522 16391928 20282603 27463775 40104979 5398

195 160220 180250 200285 230325 260365 300395 325475 390555 455650 545815 685

210 175240 195275 220310 250350 285395 325430 355515 425610 500710 600885 750

15kV - 220 mils (5.59mm), 133% Insulation LevelFull Neutral

▲141-23-9460*●141-23-9060

141-23-9066●141-23-9517

2(7x)2(7x)

1(19x)1/0(19x)

0.76 30 0.830.74 24 0.810.79 30 0.870.81 24 0.88

16x14 1.0716x14 1.0514x12 1.1416x12 1.15

792 862774 841960 1022

1065 1145

210 160210 160235 180270 205

230 175230 175260 200290 225

●141-23-9075141-23-9533

●141-23-9535

2/0(19x)3/0(19x)4/0(19x)

0.85 24 0.920.92 30 0.990.95 24 1.02

14x10 1.2316x10 1.30

18x.1073 1.34

1320 14051541 16411813 1901

310 235350 265405 305

335 255380 290440 330

1/3 Neutral

●140-23-9512140-23-9514

●140-23-9523

2(7x)1(19x)

1/0(19x)

0.74 24 0.810.79 30 0.870.81 24 0.88

6x14 1.057x14 1.109x14 1.12

657 724761 829852 933

195 160220 180250 200

210 175240 195275 220

●140-23-9025●140-23-9068●140-23-9046

2/0(19x)3/0(19x)4/0(19x)

0.85 24 0.920.92 30 0.990.95 24 1.02

11x14 1.1614x14 1.2318x14 1.26

985 10651179 12701367 1445

285 230325 260365 300

310 250350 285395 325

●140-23-9231140-23-9234

●140-23-9087

250(37x)350(37x)500(37x)

1.00 24 1.071.10 24 1.161.21 24 1.28

14x12 1.3418x12 1.43

18x.0953 1.58

1592 16742030 21732720 2906

395 325475 390555 455

430 355515 425610 500

●140-23-9096●140-23-9048

750(61x)1000(61x)

1.39 24 1.461.54 24 1.60

24x.1010 1.8324x.1167 2.01

3913 41975065 5387

650 545815 685

710 600885 750

Catalo

gNum

ber

Approx. N

et Weig

ht

(lbs./1

000’)

Approx. S

hipW

eight

(lbs./1

000’)

Catalo

gNum

ber

Conductor S

ize

AWG

/kcm

il

Nomin

al Dia

. over

Insula

tion

(in.)

Insula

tion

Screen

Thickness

(mils

)

Nomin

al Dia

. over

Insula

tion

Screen

(in.)

Copper Neutra

l

No. xAW

G(1

)

Nomin

al O.D

. (in

.)

90ºCAm

pacity

Direct B

urial (

2)

90ºCAm

pacity

Duct (2)

105ºCAm

pacity

Direct B

urial (

2)

105ºCAm

pacity

Duct (2)

Okonite’s web site, www.okonite.com contains the most up to date information.

▲Authorized stock item - Available from Customer Service Centers. ● Items use component core for quicker delivery*141-23-9460 is listed and shipped UL’s MV-90 rating on jacket. All other cables shown are available with same listing on special order.(1) Individual wire size and count may vary. The resulting combination meets 1/3 or full neutral, size requirements.** When component core is used, insulation screen thickness per ICEA S-93-639 and S-97-682.

Product DataSection 2: Sheet 42

Okoguard URO-J®

Copper Compact Round Conductor/105ºC Rating(with ICEA S-94-649 Insulation Screen Thickness)**

25kV - 260 mils (6.60mm), 100% Insulation LevelFull Neutral

141-23-4166141-23-4172141-23-4175141-23-4178141-23-4181

1(19x)1/0(19x)2/0(19x)3/0(19x)4/0(19x)

0.87 30 0.950.91 30 0.990.95 30 1.031.00 30 1.071.05 40 1.15

14x12 1.2216x12 1.2614x10 1.3416x10 1.39

18x.1073 1.48

1040 11291170 12851434 15531634 17871966 2128

235 180270 205310 235350 265405 305

260 200290 225335 255380 290440 330

1/3 Neutral

140-23-4166140-23-4172140-23-4175140-23-4178140-23-4181140-23-4184140-23-4190140-23-4193140-23-4197140-23-4199

1(19x)1/0(19x)2/0(19x)3/0(19x)4/0(19x)

250(37x)350(37x)500(37x)750(61x)

1000(61x)

0.87 30 0.950.91 30 0.990.95 30 1.031.00 30 1.071.05 40 1.151.11 40 1.211.20 40 1.301.32 40 1.421.50 40 1.601.64 55 1.78

7x14 1.199x14 1.22

11x14 1.2614x14 1.3118x14 1.3914x12 1.4818x12 1.57

18x.0953 1.7824x.1010 1.9724x.1167 2.19

839 952956 1070

1092 12061266 13811513 16651750 19122199 23842969 31974128 44345364 5765

220 180250 200285 230325 260365 300395 325475 390555 455650 545815 685

240 195275 220310 250350 285395 325430 355515 425610 500710 600885 750

35kV - 345 mils (8.76mm), 100% Insulation LevelFull Neutral

141-23-9822141-23-9825141-23-9828141-23-9831

1/0(19x)2/0(19x)3/0(19x)4/0(19x)

1.09 40 1.191.13 40 1.231.18 40 1.281.23 40 1.33

16x12 1.4614x10 1.5516x10 1.59

18x.1073 1.72

1404 15441677 17911886 20302263 2327

270 205310 235350 265405 305

290 225335 255380 290440 330

1/3 Neutral

140-23-9822140-23-9825140-23-9828140-23-9831

1/0(19x)2/0(19x)3/0(19x)4/0(19x)

1.09 40 1.191.13 40 1.231.18 40 1.281.23 40 1.33

9x14 1.4311x14 1.4614x14 1.5218x14 1.57

1185 13251319 14731512 16551739 1867

250 200285 230325 260365 300

275 220310 250350 285395 325

140-23-9834140-23-9839

●140-23-9841140-23-9846140-23-9848

250(37x)350(37x)500(37x)750(61x)

1000(61x)

1.28 40 1.381.37 40 1.471.47 24 1.541.67 55 1.801.81 55 1.95

14x12 1.6518x12 1.81

18x.0953 1.9124x.1010 2.1824x.1167 2.36

1976 21002502 26673160 34964505 49245691 6219

395 325475 390555 455650 545815 685

430 355515 425610 500710 600885 750

35kV - 420 mils (10.67mm), 133% Insulation LevelFull Neutral

141-23-9922141-23-9925141-23-9928141-23-9931

1/0(19x)2/0(19x)3/0(19x)4/0(19x)

1.25 40 1.351.29 40 1.391.34 40 1.441.39 40 1.49

16x12 1.6214x10 1.7716x10 1.81

18x.1073 1.88

1606 17451950 20852168 23322494 2662

265 210305 235345 270395 305

285 230330 255375 295430 330

1/3 Neutral

140-23-9922140-23-9924140-23-9927140-23-9928

1/0(19x)2/0(19x)3/0(19x)4/0(19x)

1.25 40 1.351.28 40 1.381.34 40 1.441.39 40 1.49

9x14 1.5911x14 1.6814x14 1.7418x14 1.79

1384 15231576 16771784 19482021 2169

250 210280 235320 265360 300

270 230305 260345 290395 330

140-23-9930140-23-9939

●140-23-9947140-23-9948140-23-9949

250(37x)350(37x)500(37x)750(61x)

1000(61x)

1.44 40 1.541.53 40 1.631.62 24 1.691.82 55 1.961.97 55 2.11

14x12 1.8718x12 1.96

18x.0953 2.0624x.1010 2.3424x.1167 2.51

2269 24382757 30143424 37564801 53806011 6547

390 330470 400555 470650 560815 700

425 365510 435605 515710 620885 770

Catalo

gNum

ber

Approx. N

et Weig

ht

(lbs./1

000’)

Approx. S

hipW

eight

(lbs./1

000’)

Catalo

gNum

ber

Conductor S

ize

AWG

/kcm

il

Nomin

al Dia

. over

Insula

tion

(in.)

Insula

tion

Screen

Thickness

(mils

)

Nomin

al Dia

. over

Insula

tion

Screen

(in.)

Copper Neutra

l

No. xAW

G(1

)

Nomin

al O.D

. (in

.)

90ºCAm

pacity

Direct B

urial (

2)

90ºCAm

pacity

Duct (2)

105ºCAm

pacity

Direct B

urial (

2)

105ºCAm

pacity

Duct (2)

Okonite’s web site, www.okonite.com contains the most up to date information.

●Items use component core for quicker delivery.*141-23-9460 is listed and shipped UL’s MV-90 rating on jacket. All other cables shown are available with same listing on special order.**When component core is used, insulation screen thickness per ICEA S-93-639 and S-97-682.

Product DataSection 2: Sheet 42

Okoguard URO-J®

15kV to 35kV Underground Primary Distribution CableJacketed - Red Identification StripesCopper Conductor/105ºC Rating 100% and 133% Insulation Level

Okonite’s web site, www.okonite.com contains the most up to date information.

Table CNInsulation Screen Thickness*

per ICEA S-94-649(for Traditional Concentric Neutral Shield)

Calculated MinimumDiameter overInsulation (In.)

Minimum Point(mils)

0 - 1.000 30

1.001 - 1.500 40

1.5001 - 2.000 55

2.001 - larger 55

Table CTInsulation Screen Thickness*

per ICEA S-93-639(for Traditional Copper Tape Shield)

Calculated MinimumDiameter overInsulation (In.)

Minimum Point(mils)

ALL 24

*Insulation Screens: Two insulation screen thicknesses are available:Cables with Compressed Round Copper Conductor (Table CN):Have extruded semiconducting ethylene-propylene rubber insulation screens that meet therequirements of ICEA S-94-649 and AEIC CS8.Cables with Compact Round Copper Conductor (Table CT):Have extruded semiconducting ethylene-propylene rubber insulation screens that meet therequirements of ICEA S-93-639/NEMA WC74 & S-97-682, AEIC CS8 and UL 1072, when component core is used.

Ampacities(2)Full neutral, single phase ampacities are based on ICEA

P-117-734 for 90ºC or 105ºC conductor temperature, 25ºCambient temperature, 100% load factor, and earth thermal resistivityof RHO 90.One third neutral ampacities are based on triplexed or triangularconfiguration for the same conditions stated above.

P/21030242 THE OKONITE COMPANYRamsey, New Jersey 07446

Composite InsulationOkoguard-Okolon TS-CPE is Okonite’s tradename for its composite insulation systemconsisting of a layer of EPR and covered witha chlorinated polyethylene (CPE) thermosetcompound.

The advantages of Okoguard EPR, with aproven track record of over 50 years as a me-dium voltage insulation, are now offered in lowvoltage cables. Okolon TS-CPE is Okonite'strade name for its chlorinated polyethylene(CPE) thermoset compound.

ApplicationsOkoguard-Okolon TS-CPE 600 Volt Powerand Control Cables are recommended for usein all low voltage circuits where continuity ofservice is the prime consideration. These ca-bles may be installed in wet or dry locations,indoors or outdoors, in raceways, undergroundducts, directly buried in the earth, or lashed toa messenger for aerial installation. These ca-bles may also be installed in cable tray (size1/0 AWG and larger per NEC 392.10(B)(1)).

SpecificationsConductor: Uncoated soft copper per ASTMB-3. Solid per ASTM B-3. Sizes smaller than#8 are compress stranded per ASTM B-8.Sizes #8 and larger are compact stranded perASTM B-496.

Insulation: Meets or exceeds all requirementsof ICEA S-95-658, NEMA WC-70 and ULStandards 44 and 854.

Listed by Underwriters Laboratories, Inc. asType RHH or RHW-2 or USE-2, VW-1. Sizes1/0 AWG and larger are also marked sunlightresistant, for use in cable tray.

Listed by CSA as RW-90, -40C, FT1 (1/0 andlarger: FT4), sunlight resistant.

** Sizes 12 AWG and larger, with exception to 6 AWG

Product Features• Sizes 1/0 AWG and larger pass the Verti-cal Tray Flame Test requirements of UL1581 for use in cable tray.

• Passes the IEEE 383-1974 Vertical TrayFlame Test. (sizes #6 AWG and larger)

• Passes the IEEE 1202 Vertical TrayFlame Test. (sizes 1/0 AWG & larger)

• Extreme heat resistance;90°C continuous rating, wet or dry130°C emergency overload rating250°C short circuit rating

• Exceptional resistance to deformation athigh temperature.

• Stable electrical properties.

• Low SIC and power factor.

• Low moisture absorption.

• Mechanically rugged.

• Resistant to weather, most oils, acids andalkalies.

• More flexible, easier to install and termi-nate than XLPE insulation.

• UL and CSA Listed.

• Multiple Conductor ConstructionsAvailable.

Okoguard-Okolon® TS-CPE Type RHHor RHW-2 or USE-2**, VW-1, FT-4, CSA RW-90600V Power and ControlCopper Conductor/90°C Wet or DryFor Cable Tray Use-Sunlight Resistant-For Direct Burial

Product DataSection 3: Sheet 1

A Uncoated, Copper ConductorB Composite Okoguard/Okolon

TS-CPE Insulation

Composite InsulationThickness (mils)

Conductor(AWG/kcmil) Okoguard

OkolonTS-CPE

14-9 30 15

8 45 15

6-2 45 30

1-4/0 55 45

250-500 65 65

750-1000 80 65

ULR

B

A

OK

ON

ITE

51/

0A

WG

CU

OK

OG

UA

RD

EP

TS

-CP

E(U

L)C

SA

112-24-2061� 112-24-2071

112-24-2091

141412

171

454545

1.141.141.14

0.160.170.18

4.064.574.57

232532

283037

151520

151520

242430

� 112-24-2101112-24-2121

� 112-24-2131

121010

717

454545

1.141.141.14

0.190.200.21

4.835.085.33

344649

395154

203030

203030

304242

112-24-2171� 112-24-2191� 112-24-2221

986

1977

456075

1.141.521.91

0.230.270.33

5.846.868.38

5875

119

6382

130

305575

305065

485575

� 112-24-2251� 112-24-2311

112-24-2331

421

77

19

7575

100

1.911.912.54

0.380.430.52

9.7511.0013.16

173257340

184280372

95130150

85115130

97130156

� 112-24-2351� 112-24-2371

112-24-2391

1/02/03/0

191919

100100100

2.542.542.54

0.560.600.64

14.1015.1416.33

414507622

446539654

170195225

150175200

179204242

� 112-24-2411� 112-24-2431� 112-24-2471

4/0250350

193737

100130130

2.543.303.30

0.700.800.89

17.6820.3222.61

766938

1265

805993

1320

260290350

230255310

278317384

� 112-24-2531� 112-24-2591� 112-24-2651

500750

1000

376161

130145145

3.303.683.68

1.011.211.36

25.6530.7334.54

175025903391

182726903568

430535615

380475545

477598689

Okonite's web site, www.okonite.com contains the most up to date information.

� Authorized stock item. Available from our Customer Service Centers. (1) Ampacities are based on Table 310.16 of the National Electrical Code forthese 90°C rated conductors at an ambient temperature of 30°C. The 75°Cwet column is provided for additional information.

The ampacities shown apply to open runs of cable, installation in any approvedraceway, direct burial in the earth, or as aerial cable on a messenger. Deratingfor more than three current carrying conductors within a raceway is in accor-dance with NEC 310.15(C)(1).

(2) Based on three (3) conductors in a single enclosed or exposed conduit. Ca-pacities based on 40°C air ambient using ICEA methods. For 30°C ambientmultiply values by 1.10; for 50°C multiply by .90. For other ambients or installa-tion conditions refer to Engineering Data Book EHB.

For ampacities in cable tray, see NEC Section 392.80.

F/21060301

Okoguard-Okolon TS-CPE Type RHHor RHW-2 or USE-2**, VW-1, FT-4, CSA RW-90600V Power and ControlCopper Conductor/90°C Wet or DryFor Cable Tray Use - Sunlight Resistant - For Direct Burial

Product DataSection 3: Sheet 1

To order a color other than black, change the last digit of thecatalog number as follows:

White 2 Orange 5

Red 3 Blue 6

Green 4 Yellow 7

Example: To order #14/Sol - Red, the catalog number would be112-24-2063.

ULR

Catalo

gNum

ber

Composit

e Insu

latio

n

Thicknes

s - mils

Number

of Strands

Conductor Size

AWG

kcm

il

Composit

e Insu

latio

n

Thicknes

s - mm

Approx.

ShipW

eight

lbs./

1000

ICEA

Ampac

ity(2

)

Approx.

O.D. -

mm

90°C

Wet

(1)*

NECAm

pacity

75°C

Wet

(1)*

NECAm

pacity

Approx.

O.D. -

Inch

es

Approx.

NetW

eight

lbs./

1000

Ramsey, New Jersey 07446THE OKONITE COMPANY

*Current limited to 15, 20 and 30 amps per Section 240.4(D)(3) of the NEC for #14, #12 and #10 AWG, respectively.**Sizes 12 AWG and larger, with exception to 6 AWG.

Composite InsulationOkoguard-Okolon® TS-CPE is Okonite’strade name for its composite insulationsystem consisting of a layer of EPR andcovered with a chlorinated polyethylene(CPE) thermoset compound. The combi-nation of the two materials provides adielectric which has excellent resistanceto heat, mechanical abuse, flame,weathering, most oils, acids and al-kalies.The advantages of Okoguard EPR, witha proven track record of over 50 yearsas a medium voltage insulation, are nowoffered in low voltage cables. OkolonTS-CPE is Okonite's trade name for itschlorinated polyethylene (CPE)thermoset compound.

ApplicationsOkoguard-Okolon TS-CPE 2000 voltpower cables are recommended for usein all low voltage circuits where continu-ity of service is the prime consideration.They can be installed in wet or dry loca-tions, indoors or outdoors in conduit,underground ducts, approved raceways.These cables may also be installed incable tray (size 1/0 AWG kcmil andlarger per NEC 392.10(B)(1)).

SpecificationsConductors: Uncoated soft copper perASTM B-3. Solid per ASTM B-3. Sizessmaller than #8 are compress strandedper ASTM B-8. Sizes #8 and larger arecompact stranded per ASTM B-496.Composite Insulation: Meets or ex-ceeds all requirements of ICEAS-95-658, NEMA WC-70 and UL Stan-dard 44.Listed by Underwriters Laboratories, Inc.as Type RHH or RHW-2, VW-1. Sizes1/0 AWG and larger are also markedsunlight resistant, for use in cable tray.All sizes meet FT-1. Sizes 1/0 andlarger meet FT-4.Listed by CSA as RW-90, -40�C, FT1(1/0 and larger: FT4), sunlight resistant.

Product Features• Sizes 1/0 AWG and larger pass theVertical Tray Flame Test require-ments of UL 1581 for use in cabletray.• Passes the IEEE 383-1974 VerticalTray Flame Test (size #8 AWG andlarger).• Passes the IEEE 1202 Vertical TrayFlame Test (sizes 1/0 AWG andlarger).• Passes the ICEA T-29-520(210,000 BTU/hr.) Vertical TrayFlame Test (sizes 2/0 AWG andlarger).• Extreme heat resistance90°C continuous rating, wet or dry130°C emergency overload rating250°C short circuit rating• Exceptional resistance to deforma-tion at high temperature.• Stable electrical properties.• Low SIC and power factor.• Low moisture absorption.• Mechanically rugged.• Resistant to weather, most oils, ac-ids and alkalies.• Smaller diameter than RHW jack-eted cables.• More flexible, easier to install, ter-minate or splice than XLPEinsulation.• OSHA acceptable.• UL and CSA Listed.

Okoguard-Okolon® TS-CPE Type RHHor RHW-2, VW-1, FT-4, CSA RW-902kV Power CableCopper Conductors/90°C Wet or DryFor Cable Tray Use - Sunlight Resistant

Product DataSection 3: Sheet 10

A Uncoated Copper ConductorB Composite Okoguard—Okolon

TS-CPE Insulation

Composite InsulationThickness (mils)

Conductor(AWG/kcmil) Okoguard Okolon

TS-CPE

14-109

8-21-4/0

250-500750-1000

455555657590

151530456565

B

A

OK

OG

UA

RD

EP

TS

-CP

E(U

L)

RH

HO

RR

HW

-2V

W-1

ULR

113-24-2061� 113-24-2071

113-24-2091

141412

171

606060

1.521.521.52

0.190.200.21

4.835.085.33

283038

333543

151520

151520

242430

� 113-24-2101113-24-2121

� 113-24-2131

121010

717

606060

1.521.521.52

0.220.230.24

5.595.846.10

405255

455760

203030

203030

304242

113-24-2171� 113-24-2191� 113-24-2221

986

1977

708585

1.792.162.16

0.280.320.35

7.118.138.89

7090

126

75101137

305575

305065

485575

� 113-24-2251� 113-24-2311

113-24-2331

421

77

19

8585

110

2.162.162.79

0.400.450.54

10.2611.4313.72

180265348

191278367

95130150

85115130

97130156

� 113-24-2351� 113-24-2371

113-24-2391

1/02/03/0

191919

110110110

2.792.792.79

0.570.610.66

14.4815.4916.76

424517633

442537657

170195225

150175200

179204242

� 113-24-2411� 113-24-2431� 113-24-2471

4/0250350

193737

110140140

2.793.563.56

0.710.830.92

18.0321.0823.37

777957

1286

81310041355

260290350

230255310

278317384

� 113-24-2531� 113-24-2591

113-24-2651

500750

1000

376161

140155155

3.563.943.94

1.041.241.38

26.4231.5035.05

177326183423

191528053674

430535615

380475545

477598689

Okonite's web site, www.okonite.com contains the most up to date information.

� Authorized stock item. Available from our Customer Service Centers. Ampacities

(1) Ampacities are based on Table 310.16 of the National Electrical Code forthese 90°C rated conductors at an ambient temperature of 30°C. The 75°C wetcolumn is provided for additional information.

The ampacities shown apply to open runs of cable, installation in any approvedraceway, direct burial in the earth, or as aerial cable on a messenger. Deratingfor more than three current carrying conductors within a raceway is in accor-dance with NEC 310.15(C)(1).

(2) Based on three (3) conductors in a single enclosed or exposed conduit. Ca-pacities based on 40°C air ambient using ICEA method. For 30°C ambientmultiply values by 1.10; for 50°C multiply by 0.89. For other ambients or instal-lation conditions refer to Okonite’s Engineering Data Book EHB.

For ampacities in cable tray see NEC Section 392.80.

I/21010310

Okoguard-Okolon TS-CPEType RHH or RHW-2, VW-1, FT-42kV Power CableCopper Conductor/90°C Wet or DryFor Cable Tray Use - Sunlight Resistant

Product DataSection 3: Sheet 10

To order a color other than black, change the last digit of thecatalog number as follows:

White 2 Orange 5

Red 3 Blue 6

Green 4 Yellow 7

Example: To order #14 - Red, the catalog number would be113-24-2073.

Catalo

gNum

ber

Approx.

ShipW

eight

lbs./

1000

ICEA

Ampac

ity(2

)

Number

of Strands

Approx.

O.D. -

mm

Composit

e Insu

latio

n

Thicknes

s - mm

75°C

Wet

(1)*

NECAm

pacity

Composit

e Insu

latio

n

Thicknes

s - mils

Approx.

O.D. -

Inch

es

Approx.

NetW

eight

lbs./

1000

Conductor Size

AWG

or kcm

il

90°C

Wet

(1)*

NECAm

pacity

Ramsey, New Jersey 07446THE OKONITE COMPANY

ULR

*Current limited to 15, 20 and 30 amps per Section 240.4(D)(3) of the NEC for #14, #12 and #10 AWG, respectively.

C-L-X Type MC-HL (XHHW-2)®

600/1000V Power MC-HL Cable - Aluminum Sheath3/C VFD & 4/C Copper Conductors/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial

A Bare, Stranded Copper ConductorsX-Olene Insulation-Color Coded forBIdentificationBare, Stranded Copper GroundingCConductor(s)

D Non-Hygroscopic Fillers, as necessaryBinder TapeEImpervious, Continuous, WeldedFCorrugated, Aluminum C-L-X Sheath

G Black Okoseal Jacket

Product DataSection 4: Sheet 1

OK

ON

ITE

SP

-OS

12

PR

16

AW

G C

U X

-OL

EN

E (

XL

PE

)

OK

ON

ITE

6 P

-OS

1 P

R 1

6A

WG

CU

X-O

LE

NE

(X

LP

E)

A

B

E

F

C

D

G

UL®

Conductor Identification: Control Sizes, #9AWG and smaller, color coded insulation. PowerSizes, #8 AWG and larger, black with printedwords of number and color.Grounding Conductor(s): One or three baresoft copper per ASTM B-3. Stranded inaccordance with UL 1581. Meets or exceedsrequirements of NEC Table 250.122.Sheath: Close fitting, impervious, continuous,welded, corrugated aluminum C-L-X per UL1569. Exceeds grounding conductorrequirements of NEC Table 250.122.Jacket: Black Okoseal (PVC) per UL1569.MeetsASTM D746 brittle point at -40°C.

Product Features• ULListed as Type MC-HLcable per UL2225(E38916).• UL Listed for cable tray use, direct burial andsunlight resistant.• UL1309 (CWCMC) listed & ULclassified inaccord with IEEE 1580 as Marine ShipboardCable rated 600/1000 volts.• Passes the IEEE 383-1974 and IEEE 1202Vertical Tray Flame Test.

• Passes the 210,000 BTU ICEAT-29-520Vertical Tray Flame Test.

• Complete pre-packaged, factory-tested wiringsystem; color coded.• C-L-X cables are quality control inspected tomeet or exceed applicable ULstandards.• 90°C continuous operating temperature in alltypes of installations.• 130°C emergency rating.• 250°C short circuit rating.• Good EMI shielding characteristics.• Impervious, continuous metallic sheath ex-cludes moisture, gases and liquids.

• Lower installed system cost than conduit orEMT systems.

• Provides excellent grounding safety.• Excellent compression and impact resistance.• Continuous long lengths.• Installation temperature of -40°C or °F.• Complies with NEC Articles 501, 502 and 503for hazardous locations.• American Bureau of Shipping Type approvedas CWCMC Type MC-HL.• Three symmetrical grounding conductors withthe CLX sheath provide a superior lowresistance return path for VFD and other modernac drive/motor applications.• CSAC22.2 No. 123 Type RA90.

• CSAC22.2 No. 174 Type HL.• CSAlisted as FT4 and LTGG (-40°C).• CSAType RA90 HLcomplies with CEC Zone 1,Zone 2, Class II Div 2, Class III Div 1 and Class IIIDiv 2 Hazardous Locations.

InsulationX-Olene is Okonite's trade name for its

®

chemically cross-linked polyethylene, withhigh dielectric strength.

Assembly and CoveringsThe individual conductors are cabled togetherwith non-hygroscopic fillers and a binder tapeoverall. The C-L-X sheath exceeds thegrounding conductor requirements of Table250.122 of the NEC and UL 1569. A barestranded copper grounding conductor(s),located in the outer interstices, is provided forgrounding. The impervious, continuous,welded, corrugated aluminum C-L-X sheathprovides complete protect ion againstmoisture, liquids and gases and has excellentmechanical strength. For direct burial in theground, embedment in concrete, or for areassubjected to corrosive atmospheres, the C-L-Xsheath is protected with a low temperatureblack Okoseal (PVC) jacket.

®

ApplicationsC-L-X Type MC-HL cables with the impervious,continuous, corrugated aluminum sheath arerecommended as an economical alternate to awire in conduit system. In addition, thealuminum CLX sheath exceeds the equipmentgrounding requirements of NEC Section250.118 and 250.122, and can be used as theequipment grounding conductor in non-HLareas.They are authorized for use on services,feeders and branch circuits for power, lighting,control and signaling circuits in accordancewithArticle 330 and 725 of the NEC.C-L-X Type MC-HL cables may be installedindoors or outdoors, in wet or dry locations, asopen runs of cable secured to supports spacednot more than six feet apart, in cable tray, asaerial cable on a messenger, in any approvedraceway, direct burial, or encased in concrete.C-L-X type MC-HL cables are also approvedfor Classes I, II and III, Division 1 and 2 andClass I, Zones 1 and 2 hazardous locations perNEC Articles 501, 502, 503 and 505; in Zone 1,Zone 2, Class II Div 2, Class III Div 1 and ClassIII Div 2 per CEC.

SpecificationsConductors: Uncoated soft copper per ASTMB-3. Sizes smaller than #8 are compressstranded per ASTM B-8. Sizes #8 and largerare compact stranded perASTM B-496.Insulation: X-Olene per ICEA S-95-658/NEMA WC70 and UL 44, Listed UL TypeXHHW-2. Meets MIL-DTL-1377H, section4.8.4.1.2 cold bend at -66°C and ASTM D746brittle point at -76°C.

3/C

1/0

AW

G C

OM

PA

CT

CU

600/1

000V

3X

10A

WG

CU

GR

D C

LX

VF

D(U

L)

MC

-HL

XH

HW

-2

Product DataSection 4: Sheet 1

UL®

Approx. N

et Weight

lbs./1000'

Approx. S

hipWeight

lbs./1000'

▲546-31-3403▲546-31-3404

14(7X)(2.08mm²)

34

30 3#183#18

0.33 8.40.37 9.3

0.53 13.50.58 14.7

50 1.2750 1.27

0.64 16.30.69 17.5

0.320.37

160 190222 261

15 1515 15

▲546-31-3453▲546-31-3454

12(7X)(3.31mm²)

34

30 3#163#16

0.37 9.30.45 11.4

0.58 14.70.67 16.9

50 1.2750 1.27

0.69 17.50.78 19.7

0.370.47

239 278286 320

20 2020 20

▲546-31-3503▲546-31-3504

10(7X)(5.26mm²)

34

30 3#143#14

0.41 10.40.45 11.4

0.62 15.80.67 16.9

50 1.2750 1.27

0.73 18.60.78 19.7

0.420.47

300 380348 428

30 3030 28

▲571-31-3190▲571-31-3263

8(7X)(8.36mm²)

34

45 3#1410

0.50 12.70.58 14.7

0.71 18.00.80 20.3

50 1.2750 1.27

0.81 20.60.90 22.9

0.520.64

385 420465 495

55 5044 40

▲571-31-3191▲571-31-3270

6(7X)(13.3mm²)

34

45 3#128

0.58 14.70.66 16.8

0.80 20.30.89 22.5

50 1.2750 1.27

0.90 22.90.99 25.1

0.640.77

525 595630 685

75 6560 52

▲571-31-3200▲571-31-3272

4(7X)(21.2mm²)

34

45 3#128

0.68 17.30.77 19.6

0.89 22.50.97 24.7

50 1.2750 1.27

0.99 25.11.08 27.5

0.770.92

704 820845 930

95 8576 68

▲571-31-3204▲571-31-3276

2(7X)(33.6mm²)

34

45 3#106

0.80 20.30.92 23.4

1.02 25.91.15 29.2

50 1.2750 1.27

1.13 28.71.26 32.0

1.001.25

995 10501245 1370

130 115104 92

571-31-3208571-31-3280

1(19X)(42.4mm²)

34

55 3#106

0.92 23.41.04 26.4

1.15 29.21.29 32.8

50 1.2750 1.27

1.26 32.01.40 35.6

1.251.54

1100 11811500 1620

145 130116 104

▲571-31-3213571-31-3285

1/0(19X)(53.5mm²)

34

55 3#106

1.00 25.51.12 28.4

1.24 31.41.37 34.9

50 1.2750 1.27

1.34 34.01.48 37.6

1.411.72

1470 15601830 1975

170 150136 120

▲571-31-3216▲571-31-3289

2/0(19X)(67.4mm²)

34

55 3#106

1.09 27.71.23 31.2

1.34 34.01.51 38.5

50 1.2760 1.52

1.44 36.61.64 41.7

1.632.11

1770 20202310 2545

195 175156 140

▲571-31-3218571-31-3291

3/0(19X)(85.1mm²)

34

55 3#86

1.19 30.21.35 34.3

1.47 37.31.64 41.7

50 1.2760 1.52

1.58 40.11.78 45.2

1.962.49

2180 24042752 2939

225 200180 160

▲571-31-3224▲571-31-3296

4/0(19X)(107mm²)

34

55 3#84

1.33 33.81.49 37.8

1.60 40.61.78 45.2

60 1.5260 1.52

1.73 44.01.91 48.6

______

2675 28803430 3710

260 230208 184

▲571-31-3228571-31-3300

250(37X)(127mm²)

34

65 3#84

1.48 37.61.64 41.6

1.74 44.21.96 49.7

60 1.5260 1.52

1.87 47.52.09 53.0

______

3140 34204070 4330

290 255232 204

▲571-31-3236▲571-31-3308

350(37X)(177mm²)

34

65 3#73

1.66 42.21.89 48.0

1.96 49.72.19 55.6

60 1.5275 1.90

2.09 53.02.35 59.8

______

4210 43005440 6000

350 310280 248

▲571-31-3244▲571-31-3316

500(37X)(253mm²)

34

65 3#62

1.94 59.32.14 54.4

2.28 57.92.49 63.2

75 1.9075 1.90

2.44 62.02.65 67.4

______

5930 64207570 8120

430 380344 304

▲571-31-3248571-31-3320

750(61X)(380mm²)

34

80 3#51

2.37 60.22.61 66.2

2.75 69.83.03 76.9

75 1.9085 2.16

2.92 74.13.21 81.6

______

8700 940011250 12190

535 475428 380

571-31-3252571-31-3324

1000(61X)(507mm²)

34

80 1/01/0

2.67 67.73.07 78.0

3.11 79.03.63 92.1

85 2.1685 2.16

3.30 83.83.81 96.8

______

11410 1243015110 17510

615 545492 436

Catalog Number

Conductor SizeAWG

Number of Conductors

Insulation Thickness - m

ils

Grounding Conductor(s

) AWG

CableO.D

. - mm

CableO.D

. - Inches

90ºCW

et or Dry

NECAm

pacity*

C-L-X Type MC-HL (XHHW-2)®

600/1000V Power MC-HL Cable - Aluminum Sheath3/C VFD & 4/C Copper Conductors/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial

C-L-XO.D

. - Inches

C-L-XO.D

. - mm

Jacket Thickness - m

ils

Jacket Thickness - m

m

Cross-S

ectional

Area (sq. In.)†

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

75ºCW

et

NECAm

pacity*

Okonite’s web site, www.okonite.com contains the most up to date information.

Product DataSection 4: Sheet 1

UL®

Approx. N

et Weight

lbs./1000'

Approx. S

hipWeight

lbs./1000'

▲546-31-3984▲571-31-3657▲571-31-3667▲571-31-3677

3X103X83X63X4

30454545

4X124X124X124X12

30303030

101088

0.75 19.00.89 22.60.93 23.60.97 24.7

0.86 21.90.99 25.11.03 26.21.08 27.5

0.580.770.830.92

425 460530 585655 720810 895

30 3055 5075 6595 85

Catalog Number

Power Conductors

Number X Size

Insulation Thickness - m

ils

Insulating Thickness - m

ils

CableO.D

. - mm

CableO.D

. - Inches

90ºCW

et or Dry

NECAm

pacity(1

)*

C-L-X Type MC-HL (XHHW-2)®

600/1000V Power MC-HL Cable - Aluminum Sheath3/C VFD & 4/C Copper Conductors/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial

C-L-XO.D

. - Inches

C-L-XO.D

. - mm

Cross-S

ectional

Area (sq. In.)†

75ºCW

et

NECAm

pacity*

600/1000V Composite Power and Control Cable - Aluminum SheathOkoseal Jacket: 50 mils (1.27mm)

Control C

onductors

Number X Size

Grounding Conductor AWG

Okonite’s web site, www.okonite.com contains the most up to date information.

▲ Available from our Customer Service Centers.Authorized Stock Item.is available on special order.Copper or Bronze C-L-X

JacketsOptional jacket types available - consult local sales office.† area for calculation of cable tray fill in accordance withCross-sectionalNEC Section 392.22.

(1) AmpacitiesAmpacities are based on Table 310.16 of the National Electrical Code forXHHW-2 conductors rated 90ºC, in a multi-conductor cable, at an ambient tem-perature of 30ºC (86ºF). The 75ºC column is provided for additional information .

The ampacities shown apply to open runs of cable, installation in any approvedraceway, direct burial in the earth, or as aerial cable on a messenger.Derating for more than three current carrying conductors within the cables is inaccordance with NEC Section 310.15(C)(1).

The ampacities shown also apply to cable installed in cable tray in accordancewith NEC Section 392.80

*Current limited to 15, 20 and 30 amps per Section 240.4(D)(3) of the NEC for #14, #12 and #10 AWG, respectively.

Product DataSection 4: Sheet 1

UL®

C-L-X Type MC-HL (XHHW-2)®

600/1000V Power MC-HL Cable - Aluminum Sheath3/C VFD & 4/C Copper Conductors/90°C Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial

ConductorNumber

Base Color

1234

BlackRedBlue

Orange

Purpose Base Color Tracer Color

Equipment Grounding UninsulatedGreenGreen 1 or more continuous yellow stripes

Grounded WhiteWhiteWhiteWhiteWhiteWhiteWhite

Black continuous stripeRed continuous stripeBlue continuous stripeOrange continuous stripeBrown continuous stripeNumeric Printing

Sizes 14, 12 & 10 AWG:Color Coding per ICEA Method 1, E-2 color sequence.Sizes 8 AWG and larger:Surface Printing of Numbers and colordesciptions per ICEA Method 3, E-2 color sequence.

THE OKONITE COMPANYRamsey, New Jersey 07446O/21010401

A Bare, Stranded Copper PowerConductorsX-Olene Insulation-Color Coded forBIdentificationStranded Control ConductorsC

D Non-Hygroscopic Fillers, as necessaryBinder TapeEImpervious, Continuous, WeldedFCorrugated, Aluminum Sheath

G Black Okoseal Jacket

Product DataSection 4: Sheet 2

OK

ON

ITE

SP

-OS

12

PR

16

AW

G C

U X

-OL

EN

E (

XL

PE

)

OK

ON

ITE

6 P

-OS

1 P

R 1

6A

WG

CU

X-O

LE

NE

(X

LP

E)

Control conductors are color coded black, red,

blue, yellow. When the control conductors are

within one standard AWG size of the power

conductors, the control conductors have an

additional tracer to facilitate identification.Grounding Conductor: Where indicated, baresoft copper per ASTM B-3. Stranded inaccordance with UL 1581. Meets or exceedsrequirements of NEC Table 250.122.Sheath: Close fitting, impervious, continuous,welded, corrugated aluminumC-L-X per UL 1569. In addition, the aluminumCLX sheath exceeds the equipment groundingrequirements of NEC Section 250.118 and250.122, and can be used as the equipmentgrounding conductor.Jacket: Black Okoseal (PVC) per UL 1569.Meets ASTM D746 brittle point at -40°C.

Product Features• UL Listed as Type MC cable per E38916.• UL 1309 (CWCMC) listed & UL classified inaccord with IEEE 1580 as Marine ShipboardCable rated 600/1000 volts.• UL Listed for cable tray use, direct burial andsunlight resistant.• Passes the IEEE 383-1974 and IEEE 1202vertical tray flame tests.• Passes the 210,000 BTU ICEA T-29-520Vertical Tray Flame Test.• Complete pre-packaged, factory-tested wiringsystem — color coded.• C-L-X cables are quality control inspected tomeet or exceed applicable UL standards.• 90°C continuous operating temperature in alltypes of installations.• 130°C emergency rating.• 250°C short circuit rating.• Good EMI shielding characteristics.• Impervious, continuous metallic sheathexcludes moisture, gases and liquids.• Lower installed system cost than conduit orEMT systems.• Provides excellent grounding safety.• Excellent compression and impact resistance.• Continuous long lengths.• Installation temperature of -40°C or °F.• American Bureau of Shipping Type approvedas CWCMC Type MC.• CSA C22.2 No. 123 listed as RA90, FT4 andLTGG (-40°C).• CSA Type RA90 complies with CEC Zone 2,Class II Div 2, Class III Div 1 and Class III Div 2Hazardous Locations.

InsulationX-Olene is Okonite's trade name for its

®

chemically cross-linked polyethylene, with highdielectric strength.

Assembly and CoveringsThe individual conductors are cabled togetherwith non-hygroscopic fillers, bare copperequipment grounding conductor, whereindicated, and a binder tape overall. The C-L-X sheath exceeds the grounding conductorrequirements of Table 250.122 of the NEC andUL 1569. The impervious, continuous, welded,corrugated aluminumC-L-X sheath provides complete protectionagainst moisture, liquids and gases and hasexcellent mechanical strength. For directburial in the ground, embedment in concrete,or for areas subjected to corrosiveatmospheres, the C-L-X sheath is protectedwith a low temperature black Okoseal (PVC)®

jacket.

ApplicationsC-L-X Type MC cables with the impervious,continuous, corrugated aluminum sheath arerecommended as an economical alternate to awire in conduit system.They are authorized for use on feeders andbranch circuits for power, lighting, control andsignaling circuits in accordance with Article 330and 725 of the NEC.C-L-X Type MC cables may be installedindoors or outdoors, in wet or dry locations, asopen runs of cable secured to supports spacednot more than six feet apart, in cable tray, asaerial cable on a messenger, in any approvedraceway, direct burial, or encased in concrete.C-L-X type MC cables are also approved foruse in Class I & II, Division 2, Class III,Divisions 1 and 2 and Class I, Zone 2hazardous locations per NEC Articles 501,502, 503 and 505; in Zone 2, Class II Div 2,Class III Div 1 and Class III Div 2 per CEC.

SpecificationsConductors: Uncoated soft copper per ASTMB-3. Sizes smaller than #8 are compressedstranded per ASTM B-8. Sizes #8 and largerare compact stranded per ASTM B-496.Insulation: X-Olene per ICEA S-95-658/NEMA WC-70, ICEA S-73-532/NEMA WC57,and UL 44, Listed UL Type XHHW-2. MeetsMIL-DTL-1377H, section 4.8.4.1.2 cold bond at-66°C and ASTM D746-04 brittle point at -76°C.Conductor Identification: Conductors 9 AWGand smaller are color coded black, red, blue,orange. Power conductors #8 AWG and largerare black with printed number/color coded.

C-L-X Type MC (XHHW-2)600/1000V Composite Power and Control MC Cable-Aluminum SheathMultiple Copper Conductors/90ºC Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial

®UL®

MC

XH

HW

-2 6

00/1

000V

3/C

8A

WG

4/C

12

AW

G

A

B

E

F

C

D

G

Product DataSection 4: Sheet 2

L/20120402

THE OKONITE COMPANYRamsey, New Jersey 07446

C-L-X Type MC (XHHW-2)600/1000V Composite Power and Control MC Cable-Aluminum SheathMultiple Copper Conductors/90ºC Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct BurialX-Olene Insulation: #14 Through #10 AWG, 30 mils (0.76mm); #8 Through #2 AWG, 45 mils (1.14mm)Okoseal Jacket: 50 mils (1.27mm)

®

UL®

Approx. N

et Weight

lbs./1000'

Approx. S

hipWeight

lbs./1000'

546-31-3983546-31-3927546-31-3950546-31-3925

3X123X124X124X12

3X144X143X144X14

―———

0.71 18.00.71 18.00.71 19.10.75 19.1

0.82 20.80.82 20.80.82 20.80.86 21.8

0.530.530.530.58

304 374320 390328 309281 351

20 2020 2020 2020 20

546-31-3758546-31-3992546-31-3990

▲ 546-31-3984

3X103X103X103X10

3X144X143X124X12

———10

0.75 19.10.80 20.30.75 19.10.75 19.1

0.86 21.80.91 23.10.86 21.80.86 21.8

0.580.650.580.58

358 428388 453296 366430 465

30 2030 3030 3030 30

546-31-3956546-31-3987546-31-3988546-31-3958

4X104X104X104X10

3X144X143X124X12

————

0.80 20.30.80 20.30.80 20.30.80 20.3

091 23.10.91 23.10.91 23.10.91 23.1

0.650.650.650.65

408 473424 489432 497455 520

30 2830 2830 2830 28

571-31-3192571-31-3661571-31-3664571-31-3665

3X83X83X83X8

3X144X143X124X12

————

0.80 20.30.84 21.30.80 20.30.84 21.3

0.91 23.10.95 24.10.91 23.10.95 24.1

0.650.710.650.71

420 500450 530450 530490 570

55 5055 5055 5055 50

▲ 571-31-3657571-31-3682571-31-3960571-31-3683

3X84X84X84X8

4X123X144X143X12

10———

0.89 22.60.84 21.30.89 22.60.89 22.6

0.99 25.10.95 24.11.00 25.41.00 25.4

0.770.710.790.79

530 585500 580525 605530 615

55 5044 4044 4044 40

571-31-3680571-31-3686571-31-3666571-31-3673

4X83X63X63X6

4X123X144X143X12

————

0.93 23.60.84 21.30.84 21.30.84 21.3

1.04 26.40.95 24.10.95 24.10.95 24.1

0.850.710.710.71

570 650520 600540 620550 630

44 4075 6575 6575 65

571-31-3668▲ 571-31-3667

571-31-3968571-31-3684

3X63X64X64X6

4X124X123X144X14

—8——

0.93 23.60.93 23.60.93 23.60.93 23.6

1.03 26.21.03 26.21.04 26.41.04 26.4

0.830.830.850.85

600 680655 720650 730660 740

75 6575 6560 5260 52

571-31-3685571-31-3965571-31-3655571-31-3970

4X64X63X43X4

3X124X123X144X14

————

0.97 24.60.97 24.60.93 23.60.93 23.6

1.08 27.41.08 27.41.04 26.41.04 26.4

0.920.920.850.85

680 760710 790700 780720 800

60 5260 5295 8595 85

571-31-3671571-31-3974

▲ 571-31-3677571-31-3688

3X43X43X44X4

3X124X124X123X14

——8—

0.93 23.60.97 24.60.97 24.71.06 26.9

1.04 26.41.08 27.41.08 27.51.17 29.7

0.850.920.921.08

720 800760 840810 895890 970

95 8595 8595 8576 68

571-31-3669571-31-3670571-31-3672571-31-3203

4X44X44X43X2

4X143X124X123X14

————

1.06 26.91.06 26.91.06 26.91.06 26.9

1.17 29.71.17 29.71.17 29.71.17 29.7

1.081.081.081.08

920 1000920 1000950 1030985 1065

76 6876 6876 68

130 115

571-31-3674571-31-3675571-31-3505571-31-3506

3X23X23X24X2

4X143X124X123X14

————

1.06 26.91.06 26.91.06 26.91.15 29.2

1.17 29.71.17 29.71.17 29.71.26 32.0

1.081.081.081.25

1000 10801010 10901040 11151230 1320

130 115130 115130 115104 92

571-31-3507571-31-3508571-31-3509

4X24X24X2

4X143X124X12

———

1.15 29.21.15 29.21.15 29.2

1.26 32.01.26 32.01.26 32.0

1.251.251.25

1250 13401260 13501280 1370

104 92104 92104 92

Catalog Number

Power Conductors

Number X Size

Control C

onductors

Number X Size

Grounding Conductor

AWGC-L-X

O.D. -

mm

C-L-XO.D

. - Inches

CableO.D

. - mm

CableO.D

. - Inches

Cross-S

ectional

Area (sq. in.)†

90ºCW

et or Dry

NECAm

pacity(1

)*

75ºCW

et

NECAm

pacity*

Okonite’s web site, www.okonite.com contains the most up to date information.

▲ Available fromAuthorized Stock Item.our Customer Service Centers.These stock items are listed as MC-HLCopper or Bronze C-L-X is availableon special order.JacketsOptional jacket types - consult local sales office.† area for calculation of cableCross-sectionaltray fill in accordance with NEC Section 392.22.

(1) AmpacitiesAmpacities are based on Table 310.16 of theNational Electrical Code for XHHW-2 conductorsrated 90ºC, in a multi-conductor cable, at anambient temperature of 30ºC (86ºF). The 75ºCcolumn is provided for additional information .

The ampacities shown apply to open runs ofcable, installation in any approved raceway,direct burial in the earth, or as aerial cable on amessenger.Derating for more than three current carryingconductors within the cables is in accordancewith NEC Section 310.15(C)(1).

The ampacities shown also apply to cableinstalled in cable tray in accordance withNEC Section 392.80

*Current limited to 15, 20 and 30 amps per Section 240.4(D) of the NEC for #14, #12 and #10 AWG, respectively.

A

B

E

D

C

InsulationOkonite-FMR is Okonite’s trade name for itsheat, moisture, flame and chemical resistant,mechanically rugged ethylene-propylene in-sulating compound.The properties of Okonite-FMR insulationsubstantially enhance the well known fea-tures of ethylene-propylene rubber insula-tions.

Overall JacketThe Okoseal (PVC) jacket is mechanicallyrugged and has excellent resistance to mostchemicals.

ApplicationsOkonite-FMR Okoseal Type TC-ER tray ca-ble is permitted for use on power, lighting,control, and signal circuits; indoors or out-doors; in cable trays, raceways, direct burialin the ground, or where supported in outdoorlocations by a messenger wire; for Class 1circuits as permitted in Article 725 of theNEC; and in cable trays in Class I, Division 2hazardous locations in industrial establish-ments where the conditions of maintenanceand supervision assure that only qualifiedpersons will service the installation. Cablesmarked TC-ER may also be used between acable tray and the utilization equipment ordevice, when installed in accordance withNEC 336.10(7).As Type Oko-Marine cable, it is suitable foruse in marine shipboard and off-shore plat-form applications in accordance with API andABS requirements.

SpecificationsConductors: Uncoated soft copper perASTM B-3. Sizes smaller than #8 are com-press stranded per ASTM B-8. Sizes #8 andlarger are compact stranded per ASTMB-496.Insulation: Okonite-FMR meets or exceedsrequirements of UL 1581, ICEA S-73-532(NEMA WC57) and ICEA S-95-658 NEMAWC70 Type II insulation.Color Coding: Base colors and tracers asshown on reverse of Data Sheet and forsizes #8 AWG and larger black conductorswith surface printing of numbers per ICEAS-73-532 NEMA/WC57 Method 4.Grounding Conductor: Where indicated,bare stranded copper per ASTM B-8, orcompact round per ASTM B-496, Class B &NEC Table 250.122.

Assembly: Conductors cabled in accor-dance with UL 1277 and 1309 using fill-ers, as necessary, with a cable tapeoverall.Overall Jacket: Complies with UL 1277and 1309. The Okoseal compound meetsor exceeds the requirements of UL 1581.UL Listed as Type TC or TC-ER cablewith a sunlight resistant low temperaturejacket and for direct burial and TypeOko-Marine cable.Sizes 4 AWG and larger without agrounding conductor are Type TC only(not ER).

Product FeaturesInsulated conductors are UL ratedXHH/XHHW-2, cUL rated RW75/RW90,VW-1, PR I, and -40�C.90°C continuous rating in wet or drylocations130°C emergency overload rating250°C short circuit rating.Okonite-FMR Okoseal Type TC-ER andOko-Marine cables are quality control in-spected to meet or exceed applicable in-dustry standards.Resistant to moisture and most chemicalatmospheres.Thermal stability at elevated tempera-tures.Flexible, easy to install and terminate.High dielectric strength.Installation Temperature -40°C.

Applicable Standards• UL listed for cable tray use, directburial, in ducts, and sunlight resistant.• Vertical Tray Flame Tests;IEEE 383-1974, FT4/IEEE 1202, UL1277, Sizes 250 kcmil and larger meetICEA T-29-520 (210,000 BTU/hr).• OSHA Acceptable• UL 1309-Oko-Marine• UL certified to IEEE 1580 - MarineShipboard Cable rated 600/1000V.• ABS Type approved; API-RP-14F,IEEE 1202, 46 CFR 111.60.• CSA C22.2 No. 239 Type CIC for sizes4/0 AWG and smaller.• CSA C22.2 No. 230 Type TC-ER forsizes 14 through 4/0 AWG.• 1000V CSA Type CIC available forsizes 4/0 AWG and smaller.

Okonite-FMR® Okoseal®UL Type TC/TC-ER (XHH/XHHW-2) and cUL CIC-TC-ER600V Power & ControlTray Cable or Oko-Marine Cable 600/1000VMultiple Copper Conductors With or WithoutGrounding Conductor/90°C Wet or DryFor Cable Tray Use - Sunlight Resistant - For Direct Burial

Product DataSection 4: Sheet 5

A Stranded Copper ConductorsB Okonite-FMR InsulationC Fillers, as necessaryD Binder TapeE Okoseal Jacket — Black

ULR

AW

GC

UO

KO

NIT

E-F

MR

PV

C60

0V

c ULR

UL TYPE: TC-ER

�202-10-3203�202-10-3204

14(7X)

34

30

——

4545

1.141.14

0.400.44

10.211.2

0.130.16

104126

127149

1515

1515

�202-10-3205�202-10-3207

202-10-3209

579

———

454560

1.141.141.52

0.480.520.63

12.213.216.0

0.180.220.32

151195260

174218292

151515

151414

�202-10-3212�202-10-3219�202-10-3237

121937

———

606080

1.521.522.03

0.710.821.14

18.020.829.0

0.400.541.03

332480925

364519

1005

121210

10108

�202-10-3403�202-10-3443

12(7X)

33

30

—12*

4545

1.141.14

0.440.48

11.212.2

0.160.18

134162

157185

2020

2020

�202-10-3404�202-10-3405�202-10-3407

457

———

454560

1.141.141.52

0.480.520.60

12.213.215.2

0.190.220.29

167202281

190225305

202020

202017

�202-10-3409�202-10-3412�202-10-3419

202-10-3437

9121937

————

60608080

1.521.522.032.03

0.700.780.951.26

17.819.824.132.0

0.390.490.731.27

363446697

1266

395485752

1266

20151512

17121210

�202-10-3503�202-10-3543�202-10-3504

202-10-4505202-10-3505* 10(7X)

33455 30

—10*———

4545606060

1.141.141.521.521.52

0.490.530.570.620.62

12.413.514.515.715.7

0.200.230.260.310.31

183223243294294

206247267318318

3030303030

3030282828

202-10-3507202-10-3509202-10-3512

7912

———

606080

1.521.522.03

0.670.780.92

17.019.823.4

0.370.490.68

384494669

416533724

282820

242417

Okonite's web site, www.okonite.com contains the most up to date information.

ULR

Okonite-FMR Okoseal®UL Type TC/TC-ER (XHH/XHHW-2) and cUL CIC-TC-ER600V Power & ControlTray Cable or Oko-Marine Cable 600/1000VMultiple Copper Conductors With or WithoutGrounding Conductor/90°C Wet or DryFor Cable Tray Use - Sunlight Resistant - for Direct Burial

Product DataSection 4: Sheet 5

� Authorized stock item —Available from our Service Centers.

Equipment Grounding Conductor: Any conductor in these cables may be per-manently re-identified during installation as the equipment grounding conductorin accordance with Section 250.119(B) of the NEC.

† Cross-sectional area for calculation of cable tray fill in accordance with Sec-tion 392.22 of the NEC.

* Method 4 Color Code

(1) Ampacities

Ampacities are based on Table 310.16 of the National Electrical Code for con-ductors rated 90°C, in a multi-conductor cable, at an ambient temperature of30°C (86°F). The 75°C column is provided for additional information.

The ampacities shown apply to open runs of cable, installation in any approvedraceway, direct burial in the earth, or as aerial cable on a messenger. Deratingfor more than three current carrying conductors within the cable is in accor-dance with NEC Section 310.15(C)(1).

The ampacities shown also apply to cables installed in cable tray in accordancewith NEC Section 392.80.

Conductor Size

AWG/kc

mil

Number

of Conductors

Groundin

gConduct

or AWG

Catalo

gNum

ber

Jack

etThick

ness (m

ils)

90°C

Wet

or Dry

NECAm

pacity

(1)*

Jack

etThick

ness (m

m)

Cross

-Sec

tional

Area (s

q. In.)

Approx.

O.D. (

In.)

Approx.

NetW

eight

lbs./

1000

Approx.

ShipW

eight

lbs./

1000

Approx.

O.D. (

mm

)

Insu

latio

nThick

ness (m

ils)

c ULR

75°C

Wet

NECAm

pacity

(1)*

*Current limited to 15, 20 and 30 amps per Section 240.4(D) of the NEC for #14, #12 and #10 AWG, respectively.

112-10-3842� 112-10-3844

112-10-3845112-10-3847

8(7X) TC-ER

3344

45

—10*—10*

60606060

1.521.521.521.52

0.640.700.700.73

16.317.817.818.5

0.320.380.380.42

273349352412

305388391451

55554545

50504040

112-10-3852� 112-10-3854

112-10-3855112-10-3857

6(7X) TC-ER

3344

45

—8*—8*

60606060

1.521.521.521.52

0.720.760.790.83

18.319.320.121.1

0.410.450.490.54

382437493582

421469532637

75756060

65655252

112-10-3862� 112-10-3864

112-10-3865112-10-3867

4(7X)

TCTC-ER

TCTC-ER

3344

45

—8*—8*

60808080

1.522.032.032.03

0.810.840.941.00

20.621.323.925.4

0.520.550.690.79

549696750891

588751805955

95957676

85856868

112-10-3872� 112-10-3874

112-10-3875112-10-3877

2(7X)

TCTC-ER

TCTC-ER

3344

45

—6—6

80808080

2.032.032.032.03

0.990.991.091.12

25.125.127.728.4

0.770.770.930.99

888941

11331242

952100512001322

130130104104

115115

9292

112-10-3882112-10-3884112-10-3885112-10-3887

1(19X)

TCTC-ER

TCTC-ER

3344

55

—6—6

80808080

2.032.032.032.03

1.101.101.211.21

27.927.930.730.7

0.950.951.151.15

1103118014341505

1170124715341605

145145116116

130130104104

112-10-3892� 112-10-3894

112-10-3895112-10-3897

1/0(19X)

TCTC-ER

TCTC-ER

3344

55

—6—6

80808080

2.032.032.032.03

1.181.181.301.23

30.030.033.031.2

1.091.091.331.19

1330141017411812

1410149018411912

170170136136

150150120120

112-10-3902� 112-10-3904

112-10-3905112-10-3907

2/0(19X)

TCTC-ER

TCTC-ER

3344

55

—6—6

80808080

2.032.032.032.03

1.271.271.401.40

32.332.335.635.6

1.271.271.541.54

1632171121142186

1732181122302302

195195156156

175175140140

112-10-3922� 112-10-3924

112-10-3925112-10-3927

4/0(19X)

TCTC-ER

TCTC-ER

3344

55

—4—4

80808080

2.032.032.032.03

1.481.481.641.64

39.439.450.050.0

————

2462257632063320

2605271933833497

260260208208

230230184184

112-10-3928112-10-3929112-10-3930112-10-3931

250(37X)

TCTC-ER

TCTC-ER

3344

65

—4—4

8080

110110

2.032.032.792.79

1.621.621.861.86

44.744.749.349.3

————

2904302938934000

3047320641594265

290290232232

255255204204

112-10-3932� 112-10-3933

112-10-3934112-10-3935

350(37X)

TCTC-ER

TCTC-ER

3344

65

—3—3

110110110110

2.792.792.792.79

1.891.892.082.08

50.350.355.655.6

————

3995416452435394

4261443055905741

350350280280

310310248248

112-10-3936� 112-10-3937

112-10-3938112-10-3939

500(37X)

TCTC-ER

TCTC-ER

3344

65

—2—2

110110110110

2.792.792.792.79

2.142.142.372.37

57.457.463.563.5

————

5549574372377425

5939613377967984

430430344344

380380304304

112-10-3940112-10-3941112-10-3942112-10-3943

750(61X)

TCTC-ER

TCTC-ER

3344

80

—1—1

110110140140

2.792.793.563.56

2.582.582.922.92

68.668.676.576.5

————

82778515

1094211157

89049142

1170411919

535535428428

475475380380

112-10-3944112-10-3945112-10-3946112-10-3947

1000(61X)

TCTC-ER

TCTC-ER

3344

80

—1/0—1/0

140140140140

3.563.563.563.56

2.962.963.283.28

77.277.285.685.6

————

10953112371433714632

11715120001527015565

615615492492

545545436436

Note: Sizes 4 AWG & larger without a grounding conductor are type TC only (not ER rated).*Ground size marked with asterisk are green insulated. **Grounds may be split.Okonite's web site, www.okonite.com contains the most up to date information.

Product DataSection 4: Sheet 5

Approx.

NetW

eight

lbs./

1000

75°C

Wet

NEC

Ampac

ity(1

)

90°C

Wet

or Dry

NECAm

pacity

(1)

Approx.

ShipW

eight

lbs./

1000

Conductor Size

AWG/kc

mil

Number

of Conductors

Groundin

gConduct

or AWG**

ULTC

TYPE

Jack

etThick

ness (m

ils)

Jack

etThick

ness (m

m)

Insu

latio

nThick

ness (m

ils)

Cross

-Sec

tional

Area (s

q. In.)

Approx.

O.D. (

In.)

Approx.

O.D. (

mm

)

Catalo

gNum

ber

Okonite-FMR OkosealUL Type TC/TC-ER (XHH/XHHW-2) and cUL CIC-TC-ER600V Power & ControlTray Cable or Oko-Marine Cable 600/1000VMultiple Copper Conductors With or WithoutGrounding Conductor/ 90°C Wet or DryFor Cable Tray Use - Sunlight Resistant - For Direct Burial

Conductor Color Coding SequenceSizes 14, 12 & 10 AWG

Conductor Color Coding per ICEA Method 1,Number Base Color Tracer Color E-2 (except 202-10-3505 - Method 4)

1 Black Sizes 8 AWG and larger:2 Red Surface Printing of Numbers per3 Blue ICEA Method 44 Orange5 Yellow6 Brown7 Red Black8 Blue Black9 Orange Black

10 Yellow Black11 Brown Black12 Black Red13 Blue Red14 Orange Red15 Yellow Red16 Brown Red17 Black Blue18 Red Blue19 Orange Blue20 Yellow Blue21 Brown Blue22 Black Orange23 Red Orange24 Blue Orange25 Yellow Orange26 Brown Orange27 Black Yellow28 Red Yellow29 Blue Yellow30 Orange Yellow31 Brown Yellow32 Black Brown33 Red Brown34 Blue Brown35 Orange Brown36 Yellow Brown37 Black

Special Order: Any or all of the following conductors may be added when specifi-cally requested by the customer to meet their specific application requirements.These conductor codings comply with UL and NEC requirements.

Purpose Base Color Tracer Color

Equipment Grounding UninsulatedGreenGreen 1 or more continuous yellow stripes

Grounded WhiteWhiteWhiteWhiteWhiteWhiteWhite

Black continuous stripeRed continuous stripeBlue continuous stripeOrange continuous stripeBrown continuous stripeNumeric Printing

T/21070405

Product DataSection 4: Sheet 5

ULR

THE OKONITE COMPANYRamsey, New Jersey 07446

c ULR

A Uncoated Copper ConductorsX-Olene InsulationBFillers, as requiredCBlack Okoseal JacketD

Product DataSection 4: Sheet 8

OK

ON

ITE

6 P

-OS

1 P

R 1

6A

WG

CU

X-O

LE

NE

(X

LP

E)

Cable passes the Vertical Tray Flame Test

requirements of UL 1277 for Type TC Power

and Control Tray Cable.

UL Listed as Type TC or TC-ER cable with a

sunlight resistant jacket and for direct burial.

Product FeaturesInsulated conductors are UL Listed Type

XHH / XHHW-2.

90°C continuous rating in wet or dry

locations.

130°C emergency overload rating.

250°C short circuit rating.

X-Olene Okoseal Type TC or TC-ER cables

are quality control inspected to meet or

exceed applicable industry standards.

Resistant to moisture and most chemical

atmospheres.

Thermal stability at elevated temperatures.

Easy to install and terminate.

Mechanically rugged.

High dielectric strength.

Small diameter, lightweight.

Minimum installation temperature of -40°C.

Applicable Standards• UL listed for cable tray use, direct burial, in

ducts, and sunlight resistant.

• Vertical Tray Flame Tests: IEEE 383-1974,

Sizes 4/0 AWG and larger meet FT4/IEEE

1202.

• CSA C22.2 No. 239 Type CIC for sizes 4/0

AWG and smaller.

• CSA C22.2 No. 230 Type TC-ER for sizes

1-4/0 AWG.

• CSA C22.2 No. 230 Type TC for sizes

smaller than 1 AWG.

• 1000V CSA Type CIC available for sizes

4/0 AWG and smaller.

InsulationX-Olene is Okonite's trade name for its cross-®

linked polyethylene, with high dielectric strength

insulation.

JacketThe Okoseal (PVC) jacket supplied with this

cable is mechanically rugged and has excellent

resistance to acids and most chemicals and is

rated for low temperature installations.

ApplicationsOkonite X-Olene Okoseal tray cable is

permitted for use on power, lighting, control,

and signal circuits; indoors or outdoors; in cable

trays, raceways, direct burial in the ground, or

where supported in outdoor locations by a

messenger wire; for Class 1 circuits as

permitted in Article 725 of the NEC; and in

cable trays in Class I, Division 2 hazardous

locations in industrial establishments where the

conditions of maintenance and supervision

assure that only qualified persons will service

the installation. Cables marked TC-ER may

also be used between a cable tray and the

utilization equipment or device, when installed

in accordance with NEC 336.10(7).

SpecificationsConductors: Uncoated soft copper per ASTM

B-3. Sizes smaller than #8 are compress

stranded per ASTM B-8. Sizes #8 and larger

are compact stranded per ASTM B-496.

Insulation: X-Olene insulation per UL 1581,

listed as XHHW-2.

Color Coding: Base colors and tracers as

shown on reverse of Data Sheet and, for sizes

#8 AWG and larger, black conductors with

surface printing of numbers and colors per

ICEA S-73-532 NEMA/WC57 Method 3.

Assembly: Conductors cabled in accordance

with UL 1277 using fillers and tape, as needed.

Grounding Conductor: Where indicated, bare

or insulated stranded copper in accordance

with NEC Table 250.122.

Overall Jacket: Complies with UL 1277. The

Okoseal compound meets or exceeds the

requirements of UL 1581.

7/C

14

AW

G C

U X

-OL

EN

E X

LP

60

0/1

00

0V

(U

L)

TC

-ER

XH

HW

-2

X-Olene -OkosealUL Type TC/TC-ER (XHH/XHHW-2) and cUL CIC-TC*600/1000 Volt Power and Control Tray CableMultiple Copper Conductors, 90°C Wet or DryWith or Without Grounding ConductorFor Cable Tray Use - Sunlight Resistant - For Direct Burial*cUL CIC-TC-ER sizes 1-4/0 AWG

® ® UL® ®

Product DataSection 4: Sheet 8

Catalog Number

Conductor Size

AWG/kcmil

Number of Conductors

UL TYPE

Insulation Thickeness - m

ils

Jacket Thickness - m

ils

Jacket Thickness - m

m

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

Approx. C

ross-S

ectional

Area (sq. in.)†

Approx. N

et Weight

lbs./1000'

Approx. S

hipWeight

lbs./1000'

90ºCW

et or Dry

NECAm

pacity(1

)*

75ºC W

et NEC

Ampacity

(1)*

▲202-31-3502▲202-31-3503▲202-31-3504

14(17X)(2.08mm²)

TCTC-ERTC-ER

234

30(0.76mm)

454545

1.141.141.14

0.37 9.40.41 10.40.43 10.9

0.110.130.15

70 85105 120120 135

15 1515 1515 15

▲202-31-3505▲202-31-3507▲202-31-3509

TC-ERTC-ERTC-ER

579

454560

1.141.141.52

0.47 11.90.50 12.70.62 15.7

0.170.200.30

132 148182 205254 278

15 1515 1415 14

▲202-31-3512202-31-3519202-31-3537

TC-ERTC-ERTC-ER

121937

606080

1.521.522.03

0.69 17.60.80 20.31.11 28.2

0.380.500.97

306 338446 485856 936

12 1012 1010 8

▲202-31-3602▲202-31-3603▲202-31-3604

12(7X)(3.31mm²)

TCTC-ERTC-ER

234

30(0.76mm)

454545

1.141.141.14

0.40 10.20.44 11.20.47 11.9

0.130.150.17

92 107139 152171 187

20 2020 2020 20

▲202-31-3605▲202-31-3607▲202-31-3609

TC-ERTC-ERTC-ER

579

456060

1.141.521.52

0.52 13.10.59 15.00.68 17.3

0.210.270.36

179 195269 293344 376

20 2020 1720 17

▲202-31-3612202-31-3619202-31-3637

TC-ERTC-ERTC-ER

121937

608080

1.522.032.03

0.77 19.60.95 24.11.24 31.5

0.470.711.21

425 464640 704

1200 1290

15 1215 1212 10

▲202-31-3702▲202-31-3703▲202-31-3704▲202-31-3705 10(7X)

(5.26mm²)

TCTC-ERTC-ERTC-ER

2345 30

(0.76mm)

45456060

1.141.141.521.52

0.45 11.40.48 12.20.56 14.20.61 15.5

0.160.180.250.29

122 138183 199242 258294 318

30 3030 3030 2830 28

▲202-31-3707202-31-3709202-31-3712

TC-ERTC-ERTC-ER

79

12

606080

1.521.522.03

0.66 16.80.77 19.60.91 23.1

0.340.470.65

378 410485 524643 698

28 2428 2420 17

X-Olene-OkosealUL Type TC/TC-ER (XHH/XHHW-2) and cUL CIC-TC*600/1000 Volt Power and Control Tray CableMultiple Copper Conductors, 90°C Wet or DryWith or Without Grounding ConductorFor Cable Tray Use - Sunlight Resistant - For Direct Burial*cUL CIC-TC-ER sizes 1-4/0 AWG

UL® ®

UL TYPE: TC-ER

202-31-3813▲202-31-3823▲202-31-3833

14(7X)12(7X)10(7X)

3 303 303 30

1#141#121#10

45 1.1445 1.1460 1.52

.43 10.9

.47 11.9

.56 14.2

0.150.170.25

120 135171 187242 248

15 1520 2030 30

Conductor Size

AWG/kcmil

Number of

Conductors

Catalog Number

Insulation Thickness

milsGreen Insulated

Grounding Conductor AWG

Jacket Thickness - m

ils

Jacket Thickness - m

m

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

Approx. C

ross-S

ectional

Area (sq. in.)†

Approx. N

et Weight

lbs./1000'

Approx. S

hipWeight

lbs./1000'

90ºCW

et or Dry

NECAm

pacity(1

)*

75ºC W

et NEC

Ampacity

(1)*

Conductor Size

AWG/kcmil

Number of

Conductors

Catalog Number

Insulation Thickness

milsBare

Grounding Conductor AWG

Jacket Thickness - m

ils

Jacket Thickness - m

m

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

Approx. C

ross-S

ectional

Area (sq. in.)†

Approx. N

et Weight

lbs./1000'

Approx. S

hipWeight

lbs./1000'

90ºCW

et or Dry

NECAm

pacity(1

)*

75ºC W

et NEC

Ampacity

(1)*

UL TYPE: TC

▲202-31-3653▲202-31-3753

12(7X)10(7X)

3 303 30

1#121#10

45 1.1460 1.52

.47 11.9

.56 14.20.170.25

141 157214 230

20 2030 30

▲ Available from our Service Centers.Authorized Stock Item.

Equipment Grounding Conductor: Any conductor in TC rated cables may be permanentlyre-identified during Installation as the equipment grounding conductor in accordancewith Section 250.119(B) of the NEC.

† Cross-sectional area for calculation of cable tray fill in accordance with NEC Section 392.22.

(1) AmpacitiesAmpacities are based on Table 310.16 of the National Electrical Code forXHHW-2 conductors rated 90ºC, in a multi-conductor cable, at an ambienttemperature of 30ºC (86ºF). Derating for more than three current carryingconductors within the cable is in accordance with NEC Section 310.15(C)(1).The ampacities shown also apply to cables installed in cable tray inaccordance with NEC Section 392.80

Product DataSection 4: Sheet 8

Catalog Number

Conductor Size

AWG/kcmil

Number of Conductors

UL TYPE

Insulation Thickeness - m

ils

Jacket Thickness - m

ils

Jacket Thickness - m

m

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

Approx. C

ross-S

ectional

Area (sq. in.)†

Approx. N

et Weight

lbs./1000'

Approx. S

hipWeight

lbs./1000'

90ºCW

et or Dry

NECAm

pacity(1

)

75ºC W

et (1)

NECAm

pacity

112-31-3734▲112-31-3735

112-31-3736112-31-3737

8(7X)(8.36mm²)

TC-ERTC-ERTC-ERTC-ER

3344

45

─10─10

60 1.5260 1.5260 1.5260 1.52

0.64 16.30.66 16.70.70 17.80.72 18.3

0.320.340.390.41

259 298313 352331 370385 424

55 5055 5044 4044 40

112-31-3746▲112-31-3747

112-31-3748112-31-3749

6(7X)(13.3mm²)

TC-ERTC-ERTC-ERTC-ER

3344

45

─8─8

60 1.5260 1.5260 1.5260 1.52

0.71 18.00.74 18.80.78 19.80.82 20.8

0.400.430.480.53

365 404440 479471 510552 616

75 6575 6560 5260 52

112-31-3758▲112-31-3759

112-31-3760112-31-3761

4(7X)(21.2mm²)

TCTC-ER

TCTC-ER

3344

45

─8─8

60 1.5260 1.5280 2.0380 2.03

0.81 20.60.81 20.60.93 23.60.96 24.4

0.520.520.680.72

527 566662 715720 784808 872

95 8595 8576 6876 68

112-31-3764▲112-31-3765

112-31-3766112-31-3767

2(7X)(33.6mm²)

TCTC-ER

TCTC-ER

3344

45

─6─6

80 2.0380 2.0380 2.0380 2.03

0.97 24.60.97 24.61.07 27.21.11 28.2

0.740.740.900.97

816 8801018 10981060 11401196 1276

130 115130 115104 92104 92

112-31-3770112-31-3771112-31-3772112-31-3773

1(19X)(42.4mm²)

TCTC-ER

TCTC-ER

3344

55

─6─6

80 2.0380 2.0380 2.0380 2.03

1.09 27.71.09 27.71.20 30.51.20 30.5

0.930.931.131.13

1051 11181127 11941355 14351431 1511

145 130145 130116 104116 104

112-31-3776▲112-31-3777

112-31-3778112-31-3779

1/0(19X)(53.5mm²)

TCTC-ER

TCTC-ER

3344

55

─6─6

80 2.0380 2.0380 2.0380 2.03

1.17 29.71.17 20.71.29 32.81.29 32.8

1.081.081.311.31

1274 13541350 14301652 17521729 1829

170 150170 150136 120136 120

112-31-3780▲112-31-3781

112-31-3782112-31-3783

2/0(19X)(67.4mm²)

TCTC-ER

TCTC-ER

3344

55

─6─6

80 2.0380 2.0380 2.0380 2.03

1.26 32.01.26 32.01.39 35.31.39 35.3

1.251.251.521.52

1561 16611639 17392033 21492109 2225

195 175195 175156 140156 140

112-31-3784▲112-31-3785

112-31-3786112-31-3787

4/0(19X)(107mm²)

TCTC-ER

TCTC-ER

3344

55

─4─4

80 2.0380 2.0380 2.0380 2.03

1.47 37.31.47 37.31.63 41.41.63 41.4

────

2361 25042488 26313101 32783222 3399

260 230260 230208 184208 184

112-31-3788112-31-3789112-31-3790112-31-3791

250(37X)(127mm²)

TCTC-ER

TCTC-ER

3344

65

─4─4

80 2.0380 2.03110 2.79110 2.79

1.62 41.21.62 41.21.85 47.01.85 47.0

────

2796 29392917 30603778 40443899 4165

290 255290 255232 204232 204

112-31-3792▲112-31-3793

112-31-3794112-31-3795

350(37X)(177mm²)

TCTC-ER

TC-TC-ER

3344

65

─3─3

110 2.79110 2.79110 2.79110 2.79

1.88 47.81.88 47.82.08 52.82.08 52.8

────

3889 41554044 43105091 54385245 5592

350 310350 310280 248280 248

112-31-3796▲112-31-3797

112-31-3798112-31-3799

500(37X)(253mm²)

TCTC-ER

TCTC-ER

3344

65

─2─2

110 2.79110 2.79110 2.79110 2.79

2.13 54.12.13 54.12.36 59.92.36 59.9

────

5386 57335581 59287082 76417276 7835

430 380430 380344 304344 304

112-31-3800▲112-31-3801

112-31-3802112-31-3803

750(61X)(380mm²)

TCTC-ER

TCTC-ER

3344

80

─1─1

110 2.79110 2.79140 3.56140 3.56

2.56 65.02.56 65.02.90 73.72.90 73.7

────

7961 85208206 8833

10632 1139410879 11641

535 475535 475428 380428 380

112-31-3804112-31-3805112-31-3806112-31-3807

1000(61X)(507mm²)

TCTC-ER

TCTC-ER

3344

80

─1/0─

1/0

140 3.56140 3.56140 3.56140 3.56

2.93 74.42.93 74.43.25 82.63.25 82.6

────

10584 1134610894 1165613925 1485814235 15168

615 545615 545492 436492 436

Okonite’s web site, www.okonite.com contains the most up to date information.

Grounding Conductor AWG

NOTE: Sizes 4 AWG & larger without a grounding conductor are Type TC only (Not ER rated).

Product DataSection 4: Sheet 8

UngroundedConductor

NumberBase Color Tracer Color

123456789

10111213141516171819202122232425262728293031323334353637

BlackRedBlue

OrangeYellowBrownRedBlue

OrangeYellowBrownBlackBlue

OrangeYellowBrownBlackRed

OrangeYellowBrownBlackRedBlue

YellowBrownBlackRedBlue

OrangeBrownBlackRedBlue

OrangeYellowBlack

BlackBlackBlackBlackBlackRedRedRedRedRedBlueBlueBlueBlueBlue

OrangeOrangeOrangeOrangeOrangeYellowYellowYellowYellowYellowBrownBrownBrownBrownBrown

Conductor Color Coding Sequence

Color CodingSizes 14,12 & 10 AWG:per ICEA Method 1, E-2 color sequence

Sizes 8 AWG and larger:Surface Printing of Numbers and colordesignation per ICEA Method 3, E-3color sequence

Special Order: Any or all of the following conductors may be added whenspecifically requested by the customer to meet their specific applicationrequirements. These conductor codings comply with UL and NEC require-ments.

THE OKONITE COMPANYRamsey, New Jersey 07446O/20120408

X-Olene-OkosealUL Type TC/TC-ER (XHH/XHHW-2) and cUL CIC-TC*600/1000 Volt Power and Control Tray CableMultiple Copper Conductors, 90°C Wet or DryWith or Without Grounding ConductorFor Cable Tray Use - Sunlight Resistant - For Direct Burial*cUL CIC-TC-ER sizes 1-4/0 AWG

UL® ®

Purpose Base Color Tracer Color

Equipment Grounding UninsulatedGreenGreen 1 or more continuous yellow stripes

Grounded WhiteWhiteWhiteWhiteWhiteWhiteWhite

Black continuous stripeRed continuous stripeBlue continuous stripeOrange continuous stripeBrown continuous stripeNumeric Printing

A Bare, Stranded Copper ConductorsX-Olene Insulation-Color Coded forBIdentificationMarker TapeC

D Non-Hygroscopic Fillers, as necessaryBinder TapeEImpervious, Continuous, Corrugated,FAluminum C-L-X Sheath

G Black Okoseal Jacket

Product DataSection 4: Sheet 14

OK

ON

ITE

6 P

-OS

1 P

R 1

6A

WG

CU

X-O

LE

NE

(X

LP

E)

C-L-X Type MC (XHHW-2)600/1000V Control Cable - Aluminum SheathMultiple Copper Conductors/90ºC Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial

®UL®

Sheath: Close fitting, impervious, continuous,corrugated aluminum C-L-X per UL 1569.In addition, the aluminum CLX sheathexceeds the equipment groundingrequirements of NEC Section 250.118 and250.122, and can be used as the equipmentgrounding conductor.Jacket: Black Okoseal (PVC) per ULrequirements for Type MC Cables. MeetsASTM D746-04 brittle point at -40°C.

Product Features• UL Listed as Type MC cable and MarineShipboard Cable, E38916 (UL 1569) andE137931 (UL 1309).• UL Listed for cable tray use, direct burial andsunlight resistant.• UL 1309 (CWCMC) listed & UL classified inaccord with IEEE 1580 as Marine ShipboardCable rated 600/1000 volts.• Passes the IEEE 383-1974 and IEEE1202/FT4 vertical tray flame tests.• Passes the 210,000 BTU/hr ICEAT-29-520 Vertical Tray Flame Test.• Complete pre-packaged, factory-testedwiring system — color coded.• C-L-X cables are quality control inspected tomeet or exceed applicable UL standards.• 90°C continuous operating temperature in alltypes of installations• 130°C emergency rating• 250°C short circuit rating.• Good EMI shielding characteristics.• Impervious, continuous metallic sheathexcludes moisture, gases and liquids.• Lower installed system cost than conduit orEMT systems.• Provides excellent grounding safety• Excellent compression and impactresistance.• Continuous long lengths.• Installation temperature of -40°C or °F.• UL and American Bureau of Shipping Typeapproved as CWCMC Type MC.• CSA C22.2 No. 123 listed as RA90, FT4 andLTGG (-40°C).• CSA Type RA90 complies with CEC Zone 2,Class II Div 2, Class III Div 1, Class III Div 2Hazardous Locations.

InsulationX-Olene is Okonite's trade name for its

®

chemically cross-linked polyethylene, with highdielectric strength.

Color CodingConductors are color coded using base colorsand tracers in accordance with the ConductorIdentification Table on the back of this DataSheet.

Assembly and CoveringsThe individual conductors are cabled togetherwith non-hygroscopic fillers and a binder tapeoverall. The C-L-X sheath exceeds thegrounding conductor requirements of Table250.122 of the NEC and UL 1569.The impervious, continuous, corrugatedaluminum C-L-X sheath provides completeprotection against moisture, liquids and gasesand has excellent mechanical strength. Fordirect burial in the ground, embedment inconcrete, or for areas subjected to corrosiveatmospheres, the C-L-X sheath is protectedwith a low temperature black Okoseal (PVC)

®

jacket.

ApplicationsC-L-X Type MC cables with the impervious,continuous, corrugated aluminum sheath arerecommended as an economical alternate to awire in conduit system.They are authorized for use on services,feeders and branch circuits for power, lighting,control and signaling circuits in accordancewith Articles 330 and 725 of the NEC.C-L-X Type MC cables may be installedindoors or outdoors, in wet or dry locations, asopen runs of cable secured to supports spacednot more than six feet apart, in cable tray, asaerial cable on a messenger, in any approvedraceway, direct burial, or encased in concrete.C-L-X Type MC cables are also approved foruse in Class I & II, Division 2, Class III,Divisions 1 and 2, and Class I, Zone 2hazardous locations per NEC articles 501,502, 503 and 505; in Zone 2, Class II Div 2,Class III Div 1 and Class III Div 2 per CEC.

SpecificationsConductors: Bare soft annealed copper,Class B stranding per ASTM B-8.Insulation: X-Olene per ICEA S-73-532/NEMA WC57 and UL 44, Listed UL TypeXHHW-2. Meets MIL-DTL-1377H, section4.8.4.1.2 cold bend at -66°C and ASTM D746-04 brittle point at -76°C.Conductor Identification: Base Colors andtracers.Assembly: Per UL 1569 with binder tapeoverall.

A

B

E

F

D

G

C

600/1

000V

7/C

12

AW

G C

U

Product DataSection 4: Sheet 14

UL®

▲ 546-31-3002▲ 546-31-3003▲ 546-31-3004

14(7X)(2.08mm²)

234

30(0.76mm)

0.280.300.33

7.17.68.4

0.490.490.53

12.312.413.5

50 1.27

0.600.600.64

15.115.216.3

0.280.320.36

142153181

174185214

151515

151515

▲546-31-3005▲546-31-3007▲546-31-3009

579

0.370.410.50

9.410.412.7

0.580.620.71

14.715.718.0

0.690.730.82

17.518.520.8

0.410.460.57

210254308

242309363

151515

151414

▲546-31-3012▲546-31-3019▲546-31-3037

121937

0.570.690.96

14.417.524.4

0.800.931.24

20.323.631.5

0.911.041.35

23.126.434.3

0.710.841.43

381537946

448604

1036

121210

10108

546-31-3082▲546-31-3083▲546-31-3084

12(7X)(3.31mm²)

234

30(0.76mm)

0.310.340.38

7.88.69.6

0.530.530.58

13.513.514.7

50 1.27

0.640.640.69

16.316.317.5

0.320.320.38

164189226

196221258

202020

202020

▲546-31-3085▲546-31-3087▲546-31-3089

579

0.420.470.56

10.611.914.2

0.620.670.80

15.717.020.3

0.730.780.91

18.519.823.1

0.420.480.65

262324405

317379472

202020

201717

▲546-31-3092▲546-31-3099▲546-31-3117

121937

0.650.781.08

16.519.827.4

0.891.021.37

22.625.934.8

0.991.131.48

25.428.737.6

0.791.001.72

503721

1301

570801

1444

151512

121210

▲546-31-3162▲546-31-3163▲546-31-3164

10(7X)(5.26mm²)

234

30(0.76mm)

0.360.390.44

9.19.9

11.1

0.580.580.67

14.714.717.0

50 1.27

0.690.690.78

17.517.519.8

0.380.380.48

202238297

234270352

303030

303028

0.820.861.001.08

20.821.825.427.4

0.530.580.790.85

348436544684

403491611751

30282820

28242417

546-31-3165▲546-31-3167

546-31-3169546-31-3172

579

12

0.480.540.650.74

12.213.716.518.8

0.710.750.890.97

18.019.122.624.6

Catalog Number

Conduct Size

AWG

Insulation

Thickness - mils

Okonite’s web site, www.okonite.com contains the most up to date information.

*Current limited to 15, 20 and 30 amps per Section 240.4(D) of the NEC for #14, #12 and #10 AWG, respectively.

C-L-X Type MC (XHHW-2)600/1000V Control Cable - Aluminum SheathMultiple Copper Conductors/90ºC Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial

®

Number of Conductors

CoreO.D

. - Inches

CoreO.D

. - mm

C-L-XO.D

. - Inches

C-L-XO.D

. - mm

Jacket Thickness - m

ils

Jacket Thickness - m

m

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

Cross-S

ectional

Area (sq. in.)†

Approx. N

et Weight

lbs./1000'

Approx. S

hipWeight

lbs./1000'

90ºCW

et or Dry

(1)

NECAm

pacity

75ºCW

et

NECAm

pacity*

▲ Available from our Customer Service Centers.Authorized Stock Item.

- is available on special order.Copper or Bronze C-L-X

† area for calculation of cable tray fill in accordance with NEC Section 392.22.Cross-sectional

Optional jacket types available - consult local sales office.Jackets -

(1) AmpacitiesAmpacities are based on Table 310.16 of the National Electrical Code forXHHW-2 conductors rated 90ºC, in a multi-conductor cable, at an ambienttemperature of 30ºC (86ºF). The 75ºC column is provided for additionalinformation .

The ampacities shown apply to open runs of cable, installation in anyapproved raceway, direct burial in the earth, or as aerial cable on amessenger. Derating for more than three current carrying conductorswithin the cable is in accordance with NEC Section 310.15(C)(1).

The ampacities shown also apply to cables installed in cable tray inaccordance with NEC Section 392.80

C-L-X Type MC (XHHW-2)600/1000V Control Cable - Aluminum SheathMultiple Copper Conductors/90ºC Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial

®

UL®

Product DataSection 4: Sheet 14

ConductorNumber Base Color Tracer Color

123456789

10111213141516171819202122232425262728293031323334353637

BlackRedBlue

OrangeYellowBrownRedBlue

OrangeYellowBrownBlackBlue

OrangeYellowBrownBlackRed

OrangeYellowBrownBlackRedBlue

YellowBrownBlackRedBlue

OrangeBrownBlackRedBlue

OrangeYellowBlack

BlackBlackBlackBlackBlackRedRedRedRedRedBlueBlueBlueBlueBlue

OrangeOrangeOrangeOrangeOrangeYellowYellowYellowYellowYellowBrownBrownBrownBrownBrown

Conductor Color Coding Sequence

Color Coding per ICEAMethod 1, E-2

Special Order: Any or all of the following conductors may be added whenspecifically requested by the customer to meet their specific applicationrequirements. These conductor codings comply with UL and NEC require-ments.

Purpose Base Color Tracer Color

Equipment Grounding UninsulatedGreenGreen 1 or more continuous

yellow stripes

Grounded WhiteWhiteWhiteWhiteWhite

WhiteWhite

Black continuous stripeRed continuous stripeBlue continuous stripeOrange continuousstripeBrown continuousstripeNumeric printing

THE OKONITE COMPANYRamsey, New Jersey 07446N/21010414

A Bare, Stranded Copper ConductorsX-Olene Insulation-Color Coded forBIdentificationStranded copper, green insulatedCgrounding conductorMarker TapeD

E Non-Hygroscopic Fillers, as necessaryBinder TapeFImpervious, Continuous, Corrugated,GAluminum C-L-X Sheath

H Black Okoseal Jacket

Product DataSection 4: Sheet 15

OK

ON

ITE

SP

-OS

12

PR

16

AW

G C

U X

-OL

EN

E (

XL

PE

)

OK

ON

ITE

6 P

-OS

1 P

R 1

6A

WG

CU

X-O

LE

NE

(X

LP

E)

C-L-X Type MC-HL (XHHW-2)600/1000V Control Cable - Aluminum SheathMultiple Copper Conductors/90ºC Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial

®UL®

MC

XH

HW

-2 6

00V

3/C

8A

WG

4/C

12

AW

G

InsulationX-Olene is Okonite's trade name for its chemically

®

cross-linked polyethylene, with high dielectric

strength.

Color CodingConductors are color coded using base colors and

tracers in accordance with the Conductor

Identification Table on the back of this Data Sheet.

Assembly and CoveringsThe individual conductors are cabled together with

non-hygroscopic fillers and a binder tape overall. The

C-L-X sheath exceeds the grounding conductor

requirements of Table 250.122 of the NEC and

UL1569.

The impervious, continuous, corrugated aluminum

C-L-X sheath provides complete protection against

moisture, liquids and gases and has excellent

mechanical strength. For direct burial in the ground,

embedment in concrete, or for areas subjected to

corrosive atmospheres, the C-L-X sheath is

protected with a low temperature black Okoseal®

(PVC) jacket.

ApplicationsC-L-X Type MC cables with the impervious,

continuous, corrugated aluminum sheath are

recommended as an economical alternate to a wire

in conduit system. In addition, the aluminum CLX

sheath exceeds the equipment grounding

requirements of NEC Section 250.118 and 250.122,

and can be used as the equipment grounding

conductor in non-HL areas.

They are authorized for use on services, feeders and

branch circuits for power, lighting, control and

signaling circuits in accordance with Articles 330 and

725 of the NEC.

C-L-X Type MC-HL cables may be installed indoors

or outdoors, in wet or dry locations, as open runs of

cable secured to supports spaced not more than six

feet apart, in cable tray, as aerial cable on a

messenger, in any approved raceway, direct burial,

or encased in concrete. C-L-X Type MC-HL cables

are also approved for Classes I, II , and III Division 1

and 2 and Class I, Zones 1 and 2 hazardous

locations per NEC Articles 501, 502, and 503 and UL

2225; in Zone Class II Div 2, Class III Div 1 and

Class III Div 2 per CEC.

SpecificationsConductors: Bare soft annealed copper, Class B

stranding per ASTM B-8.

Insulation: X-Olene per ICEA S-73-532 and UL 44,

Listed UL Type XHHW-2. Meets MIL-DTL-1377H,

section 4.8.4.1.2, cold bend at -66°C and ASTM

D746-04 brittle point at -40°C.

Conductor Identification: Base Colors and tracers.

Grounding Conductor: Green insulated stranded

copper per ASTM B-8, Class B. Meets or exceeds

requirements of NEC Table 250.122.

Assembly: Per UL 1569 with binder tape overall.

Sheath: Close fitting, impervious, continuous,

corrugated aluminum C-L-X per UL 1569.

Exceeds grounding conductor requirements of

NEC Table 250.122.

Jacket: Black Okoseal (PVC) per UL

requirements for Type MC-HL Cables. Meets

ASTM D746-04 brittle point at -40°C.

Product Features• UL Listed as Type MC-HL cable and Marine

Shipboard Cable, E38916 (UL 1569) and

E137931 (Ul1309).

• UL Listed for cable tray use, direct burial

and sunlight resistant.• UL 1309 listed (CWCMC) & UL classified inaccord with IEEE 1580 as Marine ShipboardCable rated 600/1000V.• Passes the IEEE 383-1974 and IEEE1202/FT4 vertical tray flame tests.• Passes the 210,000 BTU/hr ICEAT-29-520 Vertical Tray Flame Test.

• Complete pre-packaged, factory-tested

wiring system — color coded.• C-L-X cables are quality control inspected tomeet or exceed applicable UL standards.• 90°C continuous operating temperature inall types of installations.• 130°C emergency rating.• 250°C short circuit rating.• Good EMI shielding characteristics.• Impervious, continuous metallic sheathexcludes moisture, gasses and liquids.• Lower installed system cost than conduit orEMT systems.• Provides excellent grounding safety.• Excellent compression and impactresistance.• Continuous long lengths.• Installation temperature of -40°C or °F.• Complies with NEC Articles 501, 502 and503 for hazardous locations.• UL and American Bureau of Shipping listedas CWCMC Type MC-HL.

• CSA C22.2 No. 123 Type RA90.

• CSA C22.2 No. 174 Type HL.

• CSA listed as FT4 and LTGG (-40ºC).• CSA Type RA 90-HL complies with CECZone 1, Zone 2, Class II Div 2, Class III Div 1and Class III Div 2 Hazardous Locations.

D

E

F

G

H

C-H

L6

00

/10

00

V 7

/C 1

2A

WG

Product DataSection 4: Sheet 15

UL®

Catalog Number

Conductor SizeAWG

Green Insulated Grounding

Conductor AWG

Okonite’s web site, www.okonite.com contains the most up to date information.

*Current limited to 15, 20 and 30 amps per Section 240.4(D) of the NEC for #14, #12 and #10 AWG, respectively.

C-L-X Type MC-HL (XHHW-2)600/1000V Control Cable - Aluminum SheathMultiple Copper Conductors/90ºC Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial

®

Number of Ungro

unded

CoreO.D

. - Inches

CoreO.D

. - mm

C-L-XO.D

. - Inches

C-L-XO.D

. - mm

Jacket Thickness - m

ils

Jacket Thickness - m

m

Approx. O

.D. -

Inches

Approx. O

.D. -

mm

Cross-S

ectional

Area (sq. in.)†

Approx. N

et Weight

lbs./1000'

Approx. S

hipWeight

lbs./1000'

90ºCW

et or Dry

(1)

NECAm

pacity

75ºCW

et NEC

Ampacity

*

▲ Available from our Customer Service Centers.Authorized Stock Item.

- is available on special order.Copper or Bronze C-L-X

† area for calculation of cable tray fill in accordance with NEC Section 392.22.Cross-sectional

Optional jacket types available - consult local sales office.Jackets -

(1) Ampacities are based on Table 310.16 of the National Electrical Code forXHHW-2 conductors rated 90ºC, in a multi-conductor cable, at an ambienttemperature of 30ºC (86ºF). The 75ºC column is provided for additionalinformation .

The ampacities shown apply to open runs of cable, installation in anyapproved raceway, direct burial in the earth, or as aerial cable on amessenger. Derating for more than three current carrying conductorswithin the cable is in accordance with NEC Section 310.15(B)(1).

The ampacities shown also apply to cables installed in cable tray inaccordance with NEC Section 392.80

▲546-31-3402▲546-31-3406▲546-31-3408

14(17X)(2.08mm²)

268

#14(7X)

0.300.410.49

7.610.412.4

0.490.620.71

12.415.818.0

50 1.27

0.600.730.82

15.218.520.8

0.280.420.53

163267321

202347401

151515

151414

▲546-31-3411▲546-31-3418▲546-31-3436

111836

0.570.690.97

14.517.524.6

0.800.931.24

20.323.631.5

0.911.041.35

23.126.434.3

0.650.851.43

395554948

475634

1038

121210

10108

▲546-31-3452▲546-31-3456▲546-31-3458

12(7X)(3.31mm²)

268

#12(7X)

0.340.470.56

8.611.914.2

0.530.670.80

13.517.020.3

50 1.27

0.640.780.91

16.319.723.1

0.320.480.65

200338426

239418506

202020

201717

▲546-31-3461▲546-31-3468▲546-31-3486

111836

0.650.781.10

16.519.827.9

0.891.021.37

22.625.934.8

1.001.131.48

25.428.737.6

0.791.001.72

519739

1302

599819

1445

151512

121210

546-31-3502▲546-31-3506

10(7X)(5.26mm²)

26

#10(7X)

0.390.54

9.913.7

0.580.75

14.719.1

50 1.27

0.690.86

17.521.8

0.370.58

253451

292531

3028

3024

▲546-31-3508▲546-31-3511

811

0.650.75

16.519.1

0.890.97

22.624.6

1.001.08

25.427.4

0.790.92

568704

648784

2820

2417

C-L-X Type MC-HL (XHHW-2)600/1000V Control Cable - Aluminum SheathMultiple Copper Conductors/90ºC Wet or Dry RatingFor Cable Tray Use - Sunlight Resistant - For Direct Burial

®

UL®

Product DataSection 4: Sheet 15

UngroundedConductor

NumberBase Color Tracer Color

123456789

10111213141516171819202122232425262728293031323334353637

BlackRedBlue

OrangeYellowBrownRedBlue

OrangeYellowBrownBlackBlue

OrangeYellowBrownBlackRed

OrangeYellowBrownBlackRedBlue

YellowBrownBlackRedBlue

OrangeBrownBlackRedBlue

OrangeYellowBlack

BlackBlackBlackBlackBlackRedRedRedRedRedBlueBlueBlueBlueBlue

OrangeOrangeOrangeOrangeOrangeYellowYellowYellowYellowYellowBrownBrownBrownBrownBrown

Conductor Color Coding Sequence

Color Coding per ICEAMethod 1, E-2

Special Order: Any or all of the following conductors may be added whenspecifically requested by the customer to meet their specific applicationrequirements. These conductor codings comply with UL and NEC require-ments.

Purpose Base Color Tracer Color

Equipment Grounding UninsulatedGreenGreen 1 or more continuous

yellow stripes

Grounded WhiteWhiteWhiteWhiteWhite

WhiteWhite

Black continuous stripeRed continuous stripeBlue continuous stripeOrange continuousstripeBrown continuousstripeNumeric printing

THE OKONITE COMPANYRamsey, New Jersey 07446M/21010415

SpecificationsConductors: Bare soft annealed copper,Class B, 7-strand concentric per ASTM B-8.

Insulation: Flame-retardant Okoseal®

(PVC) per UL 13 and UL 2250, 15 milsnominal thickness, 105°C temperaturerating.

Conductor Identification: Pigmentedblack and white in pairs, black, red andwhite in triads.

Assembly: Pair or triad assembled with left-hand lay.

Cable Shield: Aluminum/synthetic polymertape overlapped to provide 100% coverage,and a 7-strand tinned copper drain wire.

Jacket: Black, flame-retardant, lowtemperature Okoseal per UL 13 and UL2250. A rip cord is laid longitudinally underthe jacket to facilitate removal.

ClassificationsUL Listed as ITC/PLTC — Instrument TrayCable/Power Limited Tray Cable for use inaccordance with Article 727 and Article 725of the National Electrical Code.

These cables comply with UL 2250 and UL13 for PLTC, CL2, and CL3.

ApplicationsOkonite type P-OS (Pair/Triad - OverallShield) instrumentation cables are de-signed for use as instrumentation,process control, and computer cables inITC non-classified or labeled circuits upto 150 volts and 5 amps (750VA) and inClass 2 or 3 Power-Limited circuitswhere shielding against external inter-ference is required, but shieldingagainst interference among groups isnot required; indoors or outdoors; in wetor dry locations with conductor operat-ing temperatures up to 105°C; in cabletrays; in raceways; supported by a mes-senger wire. Suitable Class I, Division2, Class II, Division 2, or Class III, Divi-sion 2 hazardous locations. Also for useas Power-Limited fire protective signal-ing cable (FPL) per NEC Code 760.

The overall shield eliminates most ofthe static interference from the elec-tric field radiated by power cablesand other electrical equipment.

For dc service in wet locations, X-Olene®

insulation is recommended.

Product Features• Passes the UL 1581 & IEEE 383-1974 vertical tray flame tests.

• Sunlight resistant and oil resistant.

• Individual pairs or triads are colorcoded for simplified hook-up.

• Good noise rejection.

• Excellent weathering characteristics.

• OSHA Acceptable.

• Flexible, easy to handle and terminate.

• Twisted with 100% shield coverage toreduce electromagnetic noise pick-up.

• Suitable for low temperature installa-tion of -40°C.

Type P-OSType ITC/PLTC Instrumentation CableSingle Pair or Triad - Overall Shield300 Volts - 105°C RatingFor Cable Tray Use

A Bare Stranded CopperConductor

B Okoseal InsulationC Twisted Pair/TriadD Tinned Stranded Copper Drain WireE Aluminum/Polyester TapeF Rip CordG Black Okoseal Jacket

Product DataSection 5: Sheet 2

ULR

(UL

)T

YP

EIT

C/P

LT

C10

5°c

G

A

B

C

D

E

F

Okoseal Insulation 15 mils

264-10-1101264-15-1101 22

11 12

35

0.200.21

0.030.03

2226

2731

264-10-2201264-15-2201 20

11 12

0.220.23

0.040.04

2733

3238

� 264-10-3301� 264-15-3301 18

11 15

0.230.24

0.050.05

3543

4048

� 264-10-4401264-10-4901*

� 264-15-440116

11

115

0.250.250.26

0.050.050.06

474758

525259

* Tinned Copper Conductor

� Authorized Stock Item: Available from our Customer Service Center.

� Cross-sectional area for calculation of cable tray fill in accordancewith NEC Section 392-22

Length Tolerance: Cut lengths of 1000 feet or longer are subject to atolerance of � 10%; less than 1000 feet � 15%.

G/17100502

ULR

Type P-OSType ITC/PLTC Instrumentation CableSingle Pair or Triad - Overall Shield 300V - 105°C RatingFor Cable Tray Use

Product DataSection 5: Sheet 2

ELECTRICAL SPECIFICATIONSPer UL Standard 13 & 2250

Conductor Resistance, nominal .............ohms/1000 ft. @20°C

22 AWG ............................................................... 16.520 AWG................................................................. 10.318 AWG................................................................... 6.516 AWG................................................................... 4.1

Insulation Test Voltage (spark test) ..............5000 Volts ac

Dielectric Test Voltage.........................1500 Volts ac for 15 sec.

Insulation Resistance Constant @60°F minimum(natural material typical value)..............2000 Megohms-1000 ft.

Loop Resistance, nominal (2 conductor) ohms-1000 ft @20°C

22 AWG................................................................ 33.020 AWG................................................................ 20.818 AWG................................................................ 13.016 AWG................................................................. 8.2

Mutual Capacitance (PF/ft.)*

#22 ......................................................................... 34#20 ......................................................................... 37#18 ......................................................................... 41#16 ......................................................................... 44

*Typical Value

Cross

-Sec

tional

Area �

(sq

in)

Number

of Triads

Conductor Size

(AW

G)

Jack

etThick

ness-

(mils

)

Catalo

gNum

ber

Number

of Pairs

Approx Net

Weig

ht

(lbs/1

000’)

Approx Ship

Weig

ht

(lbs/1

000’)

Nomin

alCab

le

O.D. -

(In.)

Insu

latio

nThick

ness-

(mils

)

THE OKONITE COMPANYRamsey, New Jersey 07446

E

AB

C

D

FG

H

J

SpecificationsConductors: Bare soft annealed copper, ClassB, 7-strand concentric per ASTM B-8.

Insulation: Flame-retardant Okoseal® (PVC)per UL Standard 13 and UL 2250, 15 milsnominal thickness, 105°C temperature rating.

Conductor Identification: Pigmented black andwhite in pairs, black, red and white in triads.

Assembly: Pair or triad assembled with left-handlay.

Cable Shield: Aluminum/Polyester tape over-lapped to provide 100% coverage, and a #18AWG, 7-strand tinned copper drain wire.

Inner Jacket: Black, flame-retardant Okosealper UL 13 and UL Standard 2250. A rip cord islaid longitudinally under the jacket to facilitate re-moval.

C-L-X Sheath: A close-fitting, impervious, con-tinuously welded and corrugated aluminumsheath provides complete protection againstmoisture, liquids, and gases, has excellent me-chanical strength and provides equipmentgrounding through the sheath.

Outer Jacket: Black, flame-retardant Okosealper UL 13 and UL Standard 2250.

ClassificationsUL Listed as ITC/PLTC — Instrument Tray Ca-ble/Power Limited Tray Cable for use inaccordance with Article 727 and Article 725 ofthe National Electrical Code.

These cables comply with UL 2250 and UL 13for PLTC, CL2 and CL3.

ApplicationsOkonite Type C-L-X P-OS (Pair/Triad - OverallShield) instrumentation cables are designed foruse as instrumentation, process control, andcomputer cables in ITC non-classified or labeledcircuits up to 150 volts and 5 amps (750VA) andin Class 2 or 3 Power-Limited circuits whereshielding against external interference is re-quired, but shielding against interference amonggroups is not required; indoors or outdoors; inwet or dry locations with conductor operatingtemperatures up to 105°C; in cable trays; inraceways; supported by a messenger wire; un-der raised floors; for direct burial. Suitable ClassI, Division 2, and Class I, Zone 2 Class II, Divi-sion 2, or Class III, Division 2 and Class I, Zone2 hazardous locations. Also for use asPower-Limited fire protective signaling cable(FPL) per NEC Code 760. The C-L-X sheath

provides physical protection against mechan-ical damage. It may be installed in bothexposed and concealed work, secured tosupports not greater than 6 feet apart.

The overall shield eliminates most of thestatic interference from the electric field radi-ated by power cables and other electricalequipment.

For dc service in wet locations, X-Olene® in-sulation is recommended.

Product Features• Passes the UL 1581, IEEE 383-1974, andIEEE 1202 vertical tray flame tests.

• Passes the 210,000 BTU/hr vertical trayflame test per ICEA T-29-520.

• UL listed as sunlight resistant.

• UL listed for direct burial.

• Complete pre-packaged, factory-testedwiring system-color coded.

• C-L-X enclosure permits installation in ca-ble tray containing light and power cableswithout a barrier separator.

• Individual pairs or triads are color codedfor simplified hook-up.

• Maximum noise rejection.

• Impervious, continuous sheath excludesmoisture, gases and liquids.

• In addition, the aluminum CLX sheath ex-ceeds the equipment groundingrequirements of NEC Section 250.118 and250.122, and can be used as the equipmentgrounding conductor.

• Excellent compression and impact resis-tance.

• Lower installed system cost than conduitor EMT systems.

• OSHA Acceptable.

• Meets API Standards 14F and 14FZ.

• Suitable for low temperature installation of-40°C.

C-L-X® Type P-OSType ITC/PLTC Armored Instrumentation CableSingle Pair or Triad - Overall Shield300 Volts - 105°C RatingFor Cable Tray Use

A Bare Stranded Copper ConductorB Okoseal InsulationC Twisted Pair/TriadD Tinned Stranded Copper Drain WireE Aluminum/Polyester TapeF Rip CordG Inner Black Okoseal JacketH Impervious, Continuous Corrugated

Aluminum C-L-X SheathJ Outer Black Okoseal Jacket

Product DataSection 5: Sheet 3

ULR

(UL

)T

YP

EIT

C/P

LT

C10

5°c

Conductors: 16 AWGOkoseal Insulation: 15 mils

� 564-10-3401� 564-15-3401

11

3535

.26

.285050

.43

.43.54.54

.25

.25134155

173194

� Authorized Stock Item: Available from our Customer Service Center

� Cross-sectional area for calculation of cable tray fill in accordancewith NEC Section 392.22.

Jackets- Optional jacket types available - consult local sales office.

Copper or bronze C-L-X available on special order.

To order C-L-X Type P-OS without the outer Okoseal jacket, change thesixth digit of the catalog number from 3 to 1, for example to order 1 pr.16 AWG with a bare aluminum C-L-X, the catalog number would be564-10-1401.

Length Tolerance: Cut lengths of 1000 feet or longer are subject to atolerance of � 10%; less than 1000 feet � 15%.

L/20020503

ULR

C-L-X Type P-OSType ITC/PLTC Armored Instrumentation CableSingle Pair or Triad - Overall Shield 300V - 105°C RatingFor Cable Tray Use

Product DataSection 5: Sheet 3

ELECTRICAL SPECIFICATIONSPer UL Standard 13 & 2250

Conductor Resistance, nominal .............ohms/1000 ft. @20°C

16 AWG................................................................... 4.1

Insulation Test Voltage (spark test) ..............5000 Volts ac

Dielectric Test Voltage....................................1500 Volts

Insulation Resistance Constant @60°F minimum(natural material typical value)..............2000 Megohms-1000 ft.

Loop Resistance, nominal (2 conductor) ohms-1000 ft @20°C

16 AWG................................................................. 8.2

Mutual Capacitance, typical .............................76 PF/ft.

Cross

-Sec

tional

Area �

(sq

in)

Number

of Triads

Inner

Jack

et

Thicknes

s-m

ils

Catalo

gNum

ber

Number

of Pairs

Approx Net

Weig

ht

(lbs/1

000’)

Approx Ship

Weig

ht

(lbs/1

000’)

C-L-X

O.D. -

Inch

es

Inner

Jack

et

Nomin

alO.D

. -In

ches

Outer Ja

cket

-

(mils

)

Nomin

alCab

le

O.D. -

Inch

es

THE OKONITE COMPANYRamsey, New Jersey 07446

D

A

B

G

HC

E

F

J

K

SpecificationsConductors: Bare soft annealed copper,Class B, 7-strand concentric per ASTM B-8.

Insulation: Flame-retardant Okoseal®

(PVC) per UL 13 and 2250, 15 mils nomi-nal thickness, 105°C temperature rating.

Conductor Identification: Pigmented blackand white in pairs, black, red and white in tri-ads; white conductor numerically printed forgroup identification.

Group Shield: Aluminum/Polyester tapeoverlapped to provide 100% coverage, anda 7-strand tinned copper drain wire, twosizes smaller than the conductor. All groupshields are completely isolated from eachother.

Communications Wire: 22 AWG, solid, barecopper conductor, 12 mils nominal flame-retardant Okoseal insulation, 105°C rating.

Assembly: Pairs or triads assembled with aleft-hand lay. Flame-retardant, non-wicking fillersincluded where required to provide a round ca-ble.

Cable Shield: Aluminum/Polyester tape over-lapped to provide 100% coverage, and a7-strand tinned copper drain wire, same sizeas conductor.

Jacket: Black, flame-retardant, lowtemperature Okoseal per UL Subject 13 and2250. A rip cord is laid longitudinally under thejacket to facilitate removal.

Classifications: UL Listed as ITC/PLTC - In-strument Tray Cable/Power Limited TrayCable for use in accordance with Article 727and Article 725 of the National ElectricalCode.

Cables comply with UL 2250 and UL 13 forPLTC, CL2 and CL3.

ApplicationsOkonite® Type SP-OS (Pair/triad - Individualand Overall Shield) instrumentation cables aredesigned for use as instrumentation, processcontrol, in ITC non-classified or labeled circuitsup to 150 volts and 5 amps (750VA) and inClass 2 or 3 Power-Limited circuits wheremaximum shielding against external interfer-ence is required, as well as shielding amonggroups, particularly where the cable may be

subject to abnormally high current or volt-age interference; indoors or outdoors; inwet or dry locations with conductor operat-ing temperatures up to 105°C; in cabletrays; in raceways; supported by a messen-ger wire; under raised floors. Suitable ClassI, Division 2, Class II, Division 2, or Class III,Division 2 hazardous locations. Also for useas Power-Limited fire protective signalingcable (FPL) per NEC Code 760.

The isolated individual shields overeach pair, when properly grounded,prevent crosstalk or capacitive cou-pling between adjacent pairs whichoccurs with ac signals, particularly thepulse type.

The overall shield eliminates most of thestatic interference from the electrical fieldradiated by power cables and other electri-cal equipment.

For dc service in wet locations, X-Olene®

insulation is recommended.

Product Features• Passes the UL 13 and IEEE 383-1974 ver-tical tray flame tests.

• Sunlight & oil resistant.

• Individual pairs or triads are completelyisolated.

• 100% shield coverage for reduced elec-tromagnetic noise pick-up.

• Good external noise rejection.

• Excellent weathering characteristics.

• OSHA Acceptable.

• Flexible, easy to handle and terminate.

• Communication wire included in each ca-ble for voice communication duringinstallation or instrument calibration.

• Suitable for low temperature installation of-40°C.

Type SP-OSType ITC/PLTC Instrumentation CableMultiple Shielded Pairs or Triads - Overall Shield300 Volts - 105°C RatingFor Cable Tray Use

A Bare Stranded CopperConductor

B Okoseal InsulationC Tinned Stranded Copper Group

Drain WireD Aluminum/PolyesterTapeE Twisted, Shielded Pairs/TriadsF Tinned Stranded Copper Drain WireG Aluminum/Polyester TapeH Communication WireJ Rip CordK Black Okoseal Jacket

Product DataSection 5: Sheet 13

ULR

(UL

)T

YP

EIT

C/P

LT

C10

5°c

Okoseal Insulation: 15 mils

261-10-2202261-10-2204261-10-2206

20(7X) 15

246

405050

0.350.420.51

0.100.150.20

63103138

74126161

261-10-2208261-10-2210261-10-2212

81012

506060

0.530.660.66

0.250.340.37

169219248

193258287

261-10-2216261-10-2220261-10-2224

162024

606070

0.760.820.90

0.450.530.69

311374457

350413521

261-10-2236261-10-2250

3650

7070

1.061.23

0.881.19

632845

696951

261-15-2204261-15-2208261-15-2212

48

12

505060

0.480.620.77

0.180.300.47

126212314

149236353

261-15-2216261-15-2224261-15-2236

162436

607070

0.790.991.11

0.490.770.97

397587825

436651905

261-10-3302� 261-10-3304

261-10-3306

18(7X) 15

246

505050

0.380.470.57

0.110.190.25

89133181

112156205

� 261-10-3308261-10-3310

� 261-10-3312

81012

506060

0.560.730.69

0.290.420.44

223289330

247328369

261-10-3316261-10-3320

� 261-10-3324

162024

607070

0.830.940.98

0.540.690.85

417523614

456587678

� 261-10-3336261-10-3350

3650

7080

1.141.42

1.111.58

8611188

9411294

261-15-3304261-15-3308261-15-3312

48

12

506060

0.520.680.83

0.230.410.57

165301425

188340464

261-15-3316261-15-3324261-15-3336

162436

607070

0.891.101.24

0.620.951.21

543804

1143

607884

1249

� 261-10-4402� 261-10-4404

261-10-4406

16(7X) 15

246

505060

0.430.510.66

0.170.230.34

116179260

130203299

� 261-10-4408261-10-4410

� 261-10-4412

81012

606060

0.680.820.81

0.400.530.57

323397456

362436520

261-10-4416261-10-4420

� 261-10-4424

162024

707070

0.941.061.10

0.750.881.07

600729860

664809940

261-10-4436261-10-4450

3650

8080

1.371.57

1.471.93

12501687

13561830

261-15-4404� 261-15-4408� 261-15-4412

48

12

506070

0.550.740.93

0.260.480.74

227418615

251457679

261-15-4416261-15-4424261-15-4436

162436

708080

1.021.271.43

0.821.271.61

78811671668

85212731784

� Authorized Stock Item: Available from ourCustomer Service Center.

� Cross-sectional area for calculation of cabletray fill in accordance with NEC Section 392.22

Length Tolerance: Cut lengths of 1000 feet orlonger are subject to a tolerance of � 10%; lessthan 1000 feet � 15%.

I/19100513

ULR

Type SP-OSType ITC/PLTC Instrumentation CableMultiple Shielded Pairs or Triads - Overall Shield 300V - 105°C RatingFor Cable Tray Use

Product DataSection 5: Sheet 13

ELECTRICAL SPECIFICATIONSPer UL Subject 13 & 2250

Conductor Resistance, nominal .............ohms/1000 ft. @20°C

20 AWG ............................................................... 10.418 AWG ................................................................. 6.516 AWG................................................................... 4.1

Insulation Test Voltage (spark test) ..............5000 Volts ac

Dielectric Test Voltage.........................1500 Volts ac for 15 sec.

Insulation Resistance Constant @60°F, minimum(natural material typical value)............. 2,000 Megohms-1000 ft.

Loop Resistance, nominal (2 conductor) ohms-1000 ft @20°C

20 AWG ............................................................... 20.818 AWG ............................................................... 13.016 AWG................................................................. 8.2

Mutual Capacitance (PF/ft.)*

20 AWG .................................................................. 5918 AWG................................................................... 6816 AWG................................................................... 76

*Typical Value

Cross

-Sec

tional

Area �

(sq

in)

Number

of Triads

Jack

et

Thicknes

s-m

ils

Catalo

gNum

ber

Insu

latio

nThick

ness

(mils

)

Approx Net

Weig

ht

(lbs/1

000’)

Approx Ship

Weig

ht

(lbs/1

000’)

Nomin

alCab

le

O.D. -

Inch

es

Number

of Pairs

Strand

Size(A

WG)

THE OKONITE COMPANYRamsey, New Jersey 07446

SpecificationsConductors: Bare soft annealed copper, Class B,7-strand concentric per ASTM B-8.Insulation: Flame-retardant Okoseal® (PVC) perUL 13 and 2250, 15 mils nominal thickness,105°C temperature rating.Conductor Identification: Pigmented black andwhite in pairs, black, red and white in triads;white conductor numerically printed for groupidentification.Group Shield: Aluminum/Polyester tape over-lapped to provide 100% coverage, and a 7-strandtinned copper drain wire, two sizes smaller than theconductor. All group shields are completely isolatedfrom each other.Communications Wire: 22 AWG, solid, bare cop-per conductor, 12 mils nominal flame-retardantOkoseal insulation, 105°C temperature rating.Assembly: Pairs or triads assembled with left-hand lay. Flame-retardant, non-wicking fillers in-cluded where required to provide a round cable.Cable Shield: Aluminum/Polyester tape over-lapped to provide 100% coverage, and a 7-strandtinned copper drain wire, same size as conductor.Inner Jacket: Black, flame-retardant, lowtemperature Okoseal per UL 13 and 2250. A ripcord is laid longitudinally under the jacket to facili-tate removal.C-L-X Sheath: A close-fitting, impervious, continu-ously welded and corrugated, aluminum sheathprovides complete protection against moisture, liq-uids, and gases, has excellent mechanical strength,and provides equipment grounding through thesheath.Outer Jacket: Black, flame-retardant, lowtemperature Okoseal per UL 13 and 2250.Classifications: UL Listed as ITC/PLTC - Instru-ment Tray Cable/Power Limited Tray Cable for usein accordance with Article 727 and Article 725 ofthe National Electrical Code.Cables comply with UL 2250 and UL 13 for PLTC,CL2 and CL3.

ApplicationsC-L-X Type SP-OS (Pair/triad - Individual andOverall Shield) instrumentation cables are de-signed for use as instrumentation, processcontrol, in ITC non-classified or labeled circuitsup to 150 volts and 5 amps (750VA) and inClass 2 or 3 Power-Limited circuits where max-imum shielding against external interference isrequired, as well as shielding among groups,particularly where the cable may be subject toabnormally high current or voltage interference;indoors or outdoors; in wet or dry locations withconductor operating temperatures up to 105°C;in cable trays; in raceways; supported by a

messenger wire; under raised floors or di-rect burial. Suitable in Class I & II, Division2 or Class III, Division 2 and Class I, Zone2 hazardous locations. Also for use asPower-Limited fire protective signaling ca-ble (FPL) per NEC Code 760. It may beinstalled in both exposed and concealedwork, secured to supports not greater than6 feet apart.The isolated individual shields over each pair,when properly grounded, prevent crosstalk orcapacitive coupling between adjacent pairswhich occurs with ac signals, particularly thepulse type.The overall shield eliminates most of the staticinterference from the electric field radiated bypower cables and other electrical equipment.The C-L-X sheath provides physical protectionagainst mechanical damage as well as com-plete protection against moisture or gasesentering the cable.For dc service in wet locations X-Olene® insula-tion is recommended.

Product Features• Passes the UL 13, IEEE 383-1974 vertical trayflame tests.• Passes the IEEE 1202 vertical tray flame test (2pr #18 AWG and larger).• Passes the 210,000 BTU/hr vertical tray flametest per ICEA T-29-520.• UL listed for direct burial (2 PR #20 AWG andlarger)• Complete pre-packaged, factory-tested wiringsystem-color coded.• C-L-X enclosure permits installation in cable traycontaining light and power cables without a barrierseparator.• Individual pairs or triads are completely iso-lated.• Impervious, continuous sheathexcludes moisture,gases and liquids.• In addition, the aluminum CLX sheath exceedsthe equipment grounding requirements of NECSection 250.118 and 250.122, and can be used asthe equipment grounding conductor.• Lower installed system cost than conduit orEMT systems.• Meets API Standards 14F & 14FZ.• Suitable for low temperature installation to -40°C.

C-L-X® Type SP-OSType ITC/PLTC Armored Instrumentation CableMultiple Shielded Pairs or Triads - Overall Shield300 Volts - 105°C RatingFor Cable Tray Use

A Bare Stranded Copper ConductorB Okoseal InsulationC Tinned Stranded Copper Group

Drain WireD Aluminum/PolyesterE Twisted, Shielded Pairs/TriadsF Communication WireG Aluminum/PolyesterH Tinned Stranded Copper Drain WireJ Rip CordK Inner Black Okoseal JacketL Impervious, Continuous, Corru-

gated Aluminum C-L-X SheathM Outer Black Okoseal Jacket

Product DataSection 5: Sheet 14

ULR

D

A

B

G

HC

E

F

J

K

L

M

(UL

)T

YP

EIT

C/P

LT

C10

5°c

Okoseal Insulation: 15 mils

561-10-3202561-10-3204561-10-3206

20(7X)

246

405050

0.360.430.48

0.580.620.71

505050

0.690.730.82

.37

.42

.53

198234286

217314366

561-10-3208561-10-3210561-10-3212

81012

505060

0.530.570.63

0.750.800.84

505050

0.860.911.95

.58

.65

.71

317393430

397473510

561-10-3216561-10-3220561-10-3224

162024

606070

0.720.810.90

0.971.061.15

505050

1.081.171.26

.921.081.25

501581704

581661794

561-10-3236561-10-3250

3650

7070

1.041.19

1.341.51

5060

1.451.65

1.652.14

9071230

10131373

561-15-3204561-15-3208561-15-3212

48

12

505060

0.450.560.67

0.670.800.89

505050

0.780.911.00

.48

.65

.79

258369504

338439584

561-15-3216561-15-3224561-15-3236

162436

607070

0.770.961.11

1.021.241.42

505050

1.131.351.53

1.001.431.84

604852

1117

684958

1260

� 561-10-3302� 561-10-3304

561-10-3306

18(7X)

246

405050

0.380.490.55

0.580.710.75

505050

0.690.820.86

0.370.530.58

212273338

292353418

� 561-10-3308561-10-3310

� 561-10-3312

81012

506060

0.600.670.71

0.800.890.93

505050

0.921.001.04

0.650.790.85

389479529

469559609

561-10-3316561-10-3320

� 561-10-3324

162024

606070

0.790.880.98

1.061.151.24

505050

1.171.261.35

1.081.251.43

632778889

738868995

561-10-3336561-10-3350

3650

7080

1.151.36

1.471.69

5060

1.581.82

1.962.60

12031629

13461812

561-15-3304561-15-3308561-15-3312

48

12

506060

0.540.690.79

0.750.931.06

505050

0.861.041.17

.58

.851.08

314475632

394555712

561-15-3316561-15-3324561-15-3336

162436

707080

0.901.061.29

1.151.341.60

505060

1.261.451.73

1.251.652.35

78110971539

86112401682

� 561-10-3402� 561-10-3404

561-10-3406

16(7X)

246

505050

0.440.520.59

0.670.710.84

505050

0.780.820.95

0.480.530.71

255327434

336407514

� 561-10-3408561-10-3410

� 561-10-3412

81012

606060

0.690.750.81

0.931.021.06

505050

1.041.131.17

0.851.001.08

505604671

585684777

561-10-3416561-10-3420

� 561-10-3424

162024

707070

0.951.031.10

1.241.341.37

505050

1.351.451.48

1.431.651.72

85510041245

94511011388

561-10-3436561-10-3450

3650

8080

1.291.53

1.601.87

6060

1.732.00

2.353.14

16782172

18422428

� 561-15-3404� 561-15-3408� 561-15-3412

48

12

506070

0.580.790.95

0.801.021.19

505050

0.911.131.30

0.651.001.33

384609862

464689952

561-15-3416561-15-3424561-15-3436

162436

708080

1.041.271.49

1.341.601.83

506060

1.451.731.96

1.652.353.02

105315742119

115917382306

� Authorized Stock Item: Available from our Cus-tomer Service Center.Jackets - Optional jacket types available - consultlocal sales office.� Cross-sectional area for calculation of cabletray fill in accordance with NEC Section 392.22.Copper or bronze C-L-X available on special order.To order C-L-X Type SP-OS without the outerOkoseal jacket, change the sixth digit of the cata-log number from 3 to 1. For example, to order 12 pr.20 AWG with a bare aluminum C-L-X, the catalognumber would be 561-10-1212.Length Tolerance: Cut lengths of 1000 feet orlonger are subject to a tolerance of � 10%; lessthan 1000 feet � 15%.

J/20020514

ULRC-L-X Type SP-OSType ITC/PLTC Armored Instrumentation CableMultiple Shielded Pairs or Triads - Overall Shield 300V - 105°C RatingFor Cable Tray Use

Product DataSection 5: Sheet 14

ELECTRICAL SPECIFICATIONSConductor Resistance, nominal .............ohms/1000 ft. @20°C

20 AWG....................................................................... 10.418 AWG......................................................................... 6.516 AWG......................................................................... 4.1

Insulation Test Voltage (spark test) ..............5000 Volts acDielectric Test Voltage.........................1500 Volts ac for 15 sec.Insulation Resistance Constant @60°F minimum

(natural material typical value) ......2000 Megohms-1000 ft.Loop Resistance, nominal (2 conductor) ohms-1000 ft @20°C

20 AWG....................................................................... 20.818 AWG....................................................................... 13.016 AWG......................................................................... 8.2

Mutual Capacitance (PF/ft.)*#20 ................................................................................. 59#18 ................................................................................. 68#16 ................................................................................. 76

*Typical Value

Cross

-Sec

tional

Area �

(sq

in)

Number

of Triads

Strand

Size(A

WG)

Inner

Jack

et

Thicknes

s - mils

Nomin

alCore

O.D. (

In.)

Outer Ja

cket

mils

C-L-X

O.D. (

In.)

Catalo

gNum

ber

Number

of Pairs

Approx Net

Weig

ht

(lbs/1

000’)

Approx Ship

Weig

ht

(lbs/1

000’)

Nomin

alCab

le

O.D. -

(In.)

THE OKONITE COMPANYRamsey, New Jersey 07446

SpecificationsConductors: Solid alloys per ANSI MC96.1Insulation: Flame-retardant Okoseal®

(PVC) per UL Standard 13 and 2250,15 mils nominal thickness, 105°C tem-perature rating.Conductor Identification: Pigmented in-sulation on individual conductors.Assembly: Pair assembled with left-hadlay.Cable Shield: Auminum/Polyester tapeoverlapped to provide 100% coverage,and a 7-strand tinned copper drain wire,same size as conductor.Jacket: Flame-retardant, low temperatureOkoseal per UL Standard 13 and 2250. Arip cord is laid longitudinally under thejacket to facilitate removal.Classifications: UL Listed as TypeITC/PLTC - Instrumentation Tray Ca-ble/Power Limited Tray Cable, for use inaccordance with Article 727 and 725 ofthe National Electrical Code.Cables comply with UL 2250 and ULSubject 13 for PLTC, CL2 and CL3.

ApplicationsOkonite Type P-OS (Pair/triad -Overall Shield) thermocoupleextension cables are designed for useas instrumentation and process con-trol cables in ITC non-classified orlabeled circuits up to 150 volts and 5amps (750VA) and in Class 2 of 3Power-Limited circuits where shieldingagainst external interference is re-quired, but shielding againstinterference among groups is not re-quired; indoors or outdoors; in wet ordry locations with conductor operatingtemperatures up to 105°C; in cabletrays; in raceways; supported by a

messenger wire; under raised floors;for direct burial. Suitable Class I, Divi-sion 2, Class II, Division 2, orClass III, Division 2 hazardous lo-cations.

Product Features• Passes the UL 1581 & IEEE 383-1974vertical tray flame tests.• Sunlight resistant & oil resistant..• UL listed for direct burial.• Individual pairs or triads are colorcoded for simplified hook-up.• Good noise rejection.• Excellent weathering characteristics.• OSHA Acceptable.• Flexible, easy to handle terminate.• Twisted with 100% shield coverage toreduce electromagnetic noise.• Suitable for lowtemperature installationof-40°C.

Type P-OSType ITC/PLTC Thermocouple Extension CableSingle Pair - Overall Shield - 105°C RatingFor Cable Tray Use

A Solid Thermocouple AlloyConductor

B Okoseal InsulationC Twisted Pair/TriadD Tinned Stranded Copper Drain WireE Aluminum/Polyester TapeF Rip CordG Okoseal Jacket

Product DataSection 5: Sheet 18

ULR

G

B

A

C

D

E

F

(UL

)T

YP

EIT

C/P

LT

C10

5°c

Conductors: 16 AWGOkoseal Insulation: 15 mils

EXJXKXTX

� 284-20-1401� 284-20-2401� 284-20-3401

284-20-4401

1111

35353535

.24

.24

.24

.24

.05

.05

.05

.05

44444444

49494949

� Authorized Stock Item: Available from our Cus-tomer Service Center.

SX available upon request.

(1) Special grade alloy conductors for JX and TXare available on special order.

� Cross-sectional area for calculation of cable trayfill in accordance with NEC Section 392.22

E/15040518

ULR

Type P-OSType ITC/PLTC Thermocouple Extension CableSingle Pair - Overall Shield - 105°C RatingFor Cable Tray Use

Product DataSection 5: Sheet 18

ELECTRICAL SPECIFICATIONSPer UL Standard 13 and 2250

Insulation Test Voltage (spark test) ..............5000 Volts ac

Dielectric Test Voltage.........................1500 Volts ac for 15 sec.

Shield Isolation TestPair to Cable Shield..........................exceeds 100M ohms/1000 ft.

Insulation Resistance Constant @60°F minimum(natural material typical value)..............2000 Megohms-1000 ft.

Cross

-Sec

tional

Area �

(sq

in)

Catalo

gNum

ber

Jack

etThick

ness-

(mils

)

ASA/ISA

Type

Number

of Pairs

Approx Net

Weig

ht

(lbs/1

000’)

Approx Ship

Weig

ht

(lbs/1

000’)

ASA/ISA COLOR CODE AND LIMITS OF ERROR

ASA/ISAType

Positive Wire Negative Wire OuterJacketColor

TemperatureRange°C

Limits of Error Nom. LoopResistance

Per 100’ @ 20°CAlloy Color Alloy Color Standard Special (1)

EX Chromel Purple Constantan Red Purple 0 to 200°C � 1.7°C 27.8 ohms

JX Iron White Constantan Red Black 0 to 200°C � 2.2°C � 1.1°C 13.9 ohms

KX Chromel Yellow Alumel Red Yellow 0 to 200°C � 2.2°C 23.6 ohms

TX Copper Blue Constantan Red Blue -60 to 100°C � 1.0°C � 0.5°C 12.0 ohms

Nomin

alCab

le

O.D. -

(In.)

THE OKONITE COMPANYRamsey, New Jersey 07446

D

A

B

G

H

C

EF

J

SpecificationsConductors: Solid alloys per ANSI MC96.1.

Insulation: Flame-retardant Okoseal®

(PVC) per UL Standard 13 and 2250,15 mils nominal thickness, 105°C tem-perature rating.

Conductor Identification: Pigmented in-sulating on individual conductors.

Assembly: Pairs assembled with left-hand lay

Cable Shield: Aluminum/Polyesterbacked tape overlapped to provide 100%coverage, and a 7-strand tinned copperdrain wire, same size as the conductor.

Inner Jacket: Black, flame-retardant, lowtemperature Okoseal per UL Standard 13and 2250. A rip cord is laid longitudinallyunder the jacket to facilitate removal.

C-L-X Sheath: Close fitting, impervious,continuously welded and corrugated alu-minum sheath provides completeprotection against moisture, liquids, andgases, has excellent mechanical strengthand provides equipment groundingthrough the sheath.

Outer Jacket: Flame-retardant, lowtemperature Okoseal per UL Standard 13and 2250.

Classifications: UL Listed as TypeITC/PLTC - Instrumentation Tray Ca-ble/Power Limited Tray Cable, for use inaccordance with Article 727 and 725 ofthe National Electrical Code.

Cables comply with UL 2250 and UL Sub-ject 13 for PLTC, CL2 and CL3.

ApplicationsOkonite Type C-L-X P-OS (Pair/triad -Overall Shield) Thermocouple Extensioncables are designed for use as instrumen-tation and process control cables in ITCnon-classified or labeled circuits up to 150volts and 5 amps (750VA) and in Class 2or 3 Power-Limited circuits where shield-ing against external interference isrequired, but shielding against interfer-

ence among groups is not required;indoors or outdoors; in wet or dry loca-tion with conductor operatingtemperatures up to 105°C; in cabletrays; in raceways; supported by amessenger wire; under raised floors;for direct burial. Suitable Class I, Divi-sion 2, Class II, Division 2, or Class III,Division 2 and Class I, Zone 2 hazard-ous locations. The C-L-X sheathprovides physical protection againstmechanical damage. It may be in-stalled in both exposed and concealedwork, secured to supports not greaterthan 6 feet apart.

Product Features• Passes the UL 1581, IEEE 383-1974,& IEEE 1202 vertical tray flame tests.• Passes the 210,000 BTU/hr verticaltray flame test per ICEA T-29-520.• Complete pre-packaged, factory-testedwiring system-color coded.• C-L-X cables are quality control in-spected to meet or exceed applicable ULStandards.• C-L-X enclosure permits installation incable tray containing light and power ca-bles without a barrier separator.• Individual pairs or triads are colorcoded for simplified hook-up.• Impervious, continuous sheath ex-cludes moisture, gases and liquids.• In addition, the aluminum CLX sheathexceeds the equipment grounding re-quirements of NEC Section 250.118 and250.122, and can be used as the equip-ment grounding conductor.• Lower installed system cost than conduit orEMT systems.• Meets API Standards 14F and 14FZ.• UL listed for direct burial• Suitable for low temperature installa-tion of -40°C

C-L-X® Type P-OSType ITC/PLTC Armored ThermocoupleExtension CableSingle Pair - Overall Shield - 105°C RatingFor Cable Tray Use

A Solid Thermocouple AlloyConductor

B Okoseal InsulationC Twisted PairD Tinned Stranded Copper Drain WireE Aluminum/Polyester TapeF Rip CordG Inner Okoseal JacketH Impervious, Continuous, Corru-

gated Aluminum C-L-X SheathJ Outer Okoseal Jacket

Product DataSection 5: Sheet 19

ULR

(UL

)T

YP

EIT

C/P

LT

C10

5°c

Conductors: 16 AWGOkoseal Insulation: 15 mils

EXJXKXTX

584-20-1401584-20-2401

� 584-20-3401584-20-4401

1111

35353535

.24

.24

.25

.24

.43

.43

.43

.43

50505050

.54

.54

.54

.54

.23

.23

.23

.23

128128128128

167167167167

� Authorized Stock Item: Available from our CustomerService Centers.

SX available upon request.

(1) Special grade alloy conductors for JX and TX areavailable on special order.

� Cross-sectional area for calculation of cable tray fillin accordance with NEC Section 392.22.

Jackets - Optional jacket types available - consult lo-cal sales office.

Copper or bronze C-L-X available on special order.

To order C-L-X Type P-OS without the outer Okosealjacket, change the sixth digit of the catalog numberfrom 1 to 5 for EX, 2 to 6 for JX, 3 to 7 for KX, and 4 to8 for TX. For example to order 12 pr. 20 AWG TypeKX with a bare aluminum C-L-X, the catalog numberwould be 584-20-7212.

Length Tolerance: Cut lengths of 1000 feet or longerare subject to a tolerance of � 10%; less than 1000feet � 15%.

L/20020519

ULR

C-L-X Type P-OSType ITC/PLTC Armored ThermocoupleExtension CableSingle Pair - Overall Shield - 105°C RatingFor Cable Tray Use

Product DataSection 5: Sheet 19

ELECTRICAL SPECIFICATIONSPer UL Standard 2250

Insulation Test Voltage (spark test) .......................5000 Volts ac

Dielectric Test Voltage .........................1500 Volts ac for 15 sec.

Shield Isolation TestPair to Cable Shield.......................exceeds 100M ohms/1000 ft.

Insulation Resistance Constant @60°F, minimum(natural material typical value)...............2000 Megohms-1000 ft.

Cross

-Sec

tional

Area (s

qin

) �

C-L-X

O.D. -

Inch

es

Inner

Jack

et

Thicknes

s - mils

ASA/ISA

Type

Number

of Pairs

Approx Net

Weig

ht

(lbs/1

000’)

Approx Ship

Weig

ht

(lbs/1

000’)

Inner

Jack

et

Nomin

alO.D

. -In

ches

ASA/ISA COLOR CODE AND LIMITS OF ERROR

ASA/ISAType

Positive Wire Negative Wire OuterJacketColor

TemperatureRange°C

Limits of Error Nom. LoopResistance

Per 100’ @ 20°CAlloy Color Alloy Color Standard Special (1)

EX Chromel Purple Constantan Red Purple 0 to 200°C � 1.7°C 27.8 ohms

JX Iron White Constantan Red Black 0 to 200°C � 2.2°C � 1.1°C 13.9 ohms

KX Chromel Yellow Alumel Red Yellow 0 to 200°C � 2.2°C 23.6 ohms

TX Copper Blue Constantan Red Blue -60 to 100°C � 1.0°C � 0.5°C 12.0 ohms

Outer Ja

cket

- mils

Catalo

gNum

ber

Nomin

alCab

le

O.D. -

(In.)

THE OKONITE COMPANYRamsey, New Jersey 07446

SpecificationsConductors: Bare soft annealed copper,Class B, 7-strand concentric per ASTMB-8.

Insulation & Jacket: Flame-retardantOkoseal® (PVC), 15 mils nominal thick-ness, nylon jacket, 4 mil nominalthickness, 90°C temperature rating, perUL Standard 1277.

Conductor Identification: Pigmentedblack and white in pairs, black, whiteand red in triads.

Assembly: Pair or triad assembled withleft-hand lay.

Cable Shield: Aluminum/Polyester tapeoverlapped to provide 100% coverage,and a 7-strand tinned copper drain wire,same size as conductor.

Jacket: Black, flame-retardant, lowtemperature Okoseal per UL Standard1277, 90°C temperature rating. A rip cordis laid longitudinally under the jacket to fa-cilitate removal.

Classification: UL Listed as Type TC Ar-ticle 336 of the National Electrical Code.

ApplicationsOkonite’s single pair or triad Type P-OSinstrumentation cables are designed foruse on Class 1 Remote-Control Signalingcircuits or where a 600V cable is desired,as instrumentation, process control, orcomputer cable transmitting signals atlevels above 100 milli-volts in circuitswhere shielding against external interfer-ence is required, but shielding againstinterference among groups is not re-quired. For use indoors or outdoors; wetor dry locations; in cable trays; in race-ways; supported by a messenger wire; inClass I, Division 2, Class II, Division 2 orClass III, Division 2 hazardous locations.Also for use as non power limited fire pro-tective signaling cable (NPLF) per NECCode 760. Type TC cables can be labeledOkomarine to be used in ABS and CoastGuard approved marine applications.

Type TC is authorized for use inClass I & II, Division 2 hazardouslocations.

Product Features• UL listed for cable tray use (all sizes).

• Flame Retardant - passes the verticaltray flame test requirements of IEEE383-1974 & 1202/FT4 and UL 1277.

• May be combined with 600V powerand control cables in the same tray.

• Sunlight resistant & oil resistant

• Individual pairs or triads are colorcoded for simplified hook-up.

• Good noise rejection.

• Excellent weathering characteristics.

• May be used in approved marine ap-plications.

• Flexible, easy to handle and termi-nate.

• Twisted with 100% shield coverage toreduce electromagnetic pick-up.

• OSHA Acceptable.

• Suitable for installation in low tem-perature installations to -40°C.

• CSA C22.2 No. 239 Type CIC.

Okoseal-N® Type P-OSUL Type TC and cUL Type CIC Instrumentation CableSingle Pair or Triad - Overall Shield600 Volts - 90°C Rating Wet or Dry

A Stranded Bare Copper ConductorB Okoseal Insulation with Nylon

JacketC Twisted Pair/TriadD Stranded Tinned Copper Drain WireE Aluminum/Synthetic Polymer TapeF Rip CordG Black Okoseal Jacket

Product DataSection 5: Sheet 29

E

ABC

D

FG

(UL

)T

YP

ET

CO

RC

(UL

)T

YP

EC

IC

ULR c ULR

Okoseal Insulation: 15 milsNylon Jacket: 4 mils

� 264-60-3301264-65-3301

1818

11

45

0.270.29

0.060.07

4854

5359

� 264-60-4401� 264-65-4401

1616

11

0.290.31

0.070.08

5669

6180

� 264-60-5501264-65-5501

1414

11

0.320.34

0.090.10

7594

86105

� Cross-sectional area for calculation of cable tray fill inaccordance with NEC Section 392-22

Length Tolerance: Cut lengths of 1000 feet or longer aresubject to a tolerance of � 10%; less than 1000 feet � 15%.

� Authorized Stock Item: Available from our CustomerService Centers.

L/19110529

Okoseal-N Type P-OSUL Type TC and cUL Type CIC Instrumentation CableSingle Pair or Triad - Overall Shield600V - 90°C Rating Wet or Dry

Product DataSection 5: Sheet 29

ELECTRICAL SPECIFICATIONSPer UL Standard 1277

Conductor Resistance, maximumohms/1000 ft.. . . . . . . . . . . . . . . . . . . . . . . . . . . . @20°C ..........@25°C

18 AWG . . . . . . . . . . . . . . . . . . . . 6.09···············7.0416 AWG . . . . . . . . . . . . . . . . . . . . 4.34···············4.4314 AWG . . . . . . . . . . . . . . . . . . . . . 2.72···············2.78

Insulation Test Voltage (spark test)

18 - 16 AWG . . . . . . . . . . . . . . 6000 volts ac14 AWG . . . . . . . . . . . . . . . . . . 7500 volts ac

Dielectric Test Voltage

18-16 AWG . . . . . . . . . . . . . . . 1500 volts ac for 1 minute14 AWG . . . . . . . . . . . . . . . . . . 2000 volts ac for 1 minute

Shield Isolation Test

Pair to Cable Shield . . . exceeds 100 Megohms/1000 ft.

Insulation Resistance Constant @60°F minimum(natural material typical value) ..........2000 Ohms-1000 ft.

Loop Resistance, nominal (2 conductor)ohms-1000 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . @20°C ..........@25°C

18 AWG . . . . . . . . . . . . . . . . . . . 12.18·············14.0816 AWG . . . . . . . . . . . . . . . . . . . . 8.68···············8.8614 AWG . . . . . . . . . . . . . . . . . . . . 5.44···············5.56

Cross

-Sec

tional

Area �

(sq

in)

Number

of Triads

SizeAW

G

Catalo

gNum

ber

Number

of Pairs

Approx Net

Weig

ht

(lbs/1

000’)

Approx Ship

Weig

ht

(lbs/1

000’)

Nomin

alCab

le

O.D. -

(In.)

Jack

etThick

ness-

(mils

)

Mutual Capacitance 18 AWG ......................49 pF/ft16 AWG ......................56 pF/ft14 AWG ......................64 pF/ft

L/R ratio 18 AWG ......................14 micro Henry/ohm16 AWG ......................21 micro Henry/ohm14 AWG ......................31 micro Henry/ohm

Inductance 18 AWG ......................0.19 micro Henry/ft16 AWG ......................0.18 micro Henry/ft14 AWG ......................0.17 micro Henry/ft

THE OKONITE COMPANYRamsey, New Jersey 07446

ULR c ULR

SpecificationsConductors: Bare soft annealed copper,Class B, 7-strand concentric per ASTM B-8.Insulation: Flame-retardant Okoseal®

(PVC), 15 mils nominal thickness, nylonjacket, 4 mil nominal thickness, 90°C tem-perature rating, per UL Standard 1277.Conductor Identification: Pigmented blackand white in pairs; black, white and redin triads.Group Shield: Aluminum/Polyester tape over-lapped to provide 100% coverage, and a7-strand tinned copper drain wire, two sizessmaller than the conductor. All group shieldsare completely isolated from each other.Assembly: Pairs or triads assembled with1 left-hand lay. Flame-retardant, non-wickingfillers included where required to provide around cable.Cable Shield: Aluminum/Polyester tape over-lapped to provide 100% coverage, and a7-strand tinned copper drain wire, same sizeas conductor.Jacket: Black, flame-retardant, lowtemperature Okoseal per UL Standard 1277,90°C temperature rating. A rip cord is laid lon-gitudinally under the jacket to facilitateremoval.Classification: UL Listed as Type TC Article336 of the National Electrical Code.

ApplicationsOkonite’s Type SP-OS (Shielded pairs or tri-ads - Overall Shield) instrumentation cablesare designed for use on Class 1 Remote-Control Signaling circuits or where a 600V ca-ble is desired, as instrumentation, processcontrol, or computer cable transmitting signalsat levels above 100 mili-volts in circuits wheremaximum noise protection is required. Protec-tion from interference among groups as well asexternal sources is provided by individualgroup shields as well as an overall cableshield. For use indoors or outdoors; wet or drylocations; in raceways; supported by a mes-senger wire; for direct burial; in Class I,Division 2, Class II, Division 2 or Class III, Di-vision 2 hazardous locations. Also for use asnon power limited fired protective signaling ca-ble (NPLF) per NEC Code 760. As an option,type TC cables can be labeled Okomarine tobe used in ABS and Coast Guard approvedmarine applications, on special order.

Product Features• UL listed for cable tray use (all sizes).

• Passes the UL 1277 and IEEE 383-1974vertical tray flame tests.

• Passes IEEE 1202/FT4 vertical trayflame test.

• May be combined with 600 volt powerand control cables in the same tray.

• Sunlight resistant and oil resistant.

• UL listed for direct burial (8/pr #16 AWGand larger)

• Individual pairs or triads are numberedand color-coded for simplified hook-up.

• Individual pairs or triads are completelyisolated.

• 100% shield coverage for reduced elec-tromagnetic noise pick-up.

• Good external noise rejection.

• Excellent weathering characteristics.

• OSHA Acceptable.

• Flexible, easy to handle and termi-nate.

• Suitable for installation at low tem-peratures to -40°C.

• CSA C22.2 No. 239 Type CIC.

Okoseal-N® Type SP-OSUL Type TC and cUL Type CIC Instrumentation CableMultiple Shielded Pairs or Triads - Overall Shield600 Volts - 90°C Rating Wet or Dry

Product DataSection 5: Sheet 31

A Stranded Bare Copper ConductorB Okoseal Insulation with Nylon

JacketC Tinned Stranded Copper Group

Drain WireD Double Faced Aluminum/Synthetic

Polymer Backed TapeE Twisted, Shielded Pairs/TriadsF Double Faced Aluminum/Synthetic

Polymer Backed TapeG Stranded Tinned Copper Drain WireH Rip CordJ Black Okoseal Jacket

(UL

)T

YP

ET

CO

RC

(UL

)T

YP

EC

ICULR c ULR

Okoseal Insulation - 15 mils; Nylon Jacket - 4 mils

261-60-3302261-60-3304261-60-3308

18 (7x)

248

454560

0.420.500.67

0.140.200.35

83138254

96161297

261-60-3310261-60-3312261-60-3316

101216

608080

0.770.810.93

0.460.510.67

316395496

355459559

261-60-3320261-60-3324261-60-3336261-60-3350

20243650

80808080

1.071.091.281.55

0.900.931.291.89

597699974

1307

677779

10801450

261-65-3304261-65-3308261-65-3312

48

12

606080

0.610.750.95

0.290.440.71

196317516

220356580

261-65-3316261-65-3324261-65-3336

162436

808080

1.091.341.53

0.931.411.84

652940

1319

73210461462

� 261-60-4402� 261-60-4404� 261-60-4408

16 (7x)

248

456060

0.440.580.72

0.150.260.47

114198337

137222376

261-60-4410� 261-60-4412� 261-60-4416

101216

808080

0.940.911.04

0.690.650.85

452515639

516579692

261-60-4420� 261-60-4424

261-60-4436261-60-4450

20243650

808080

110

1.191.181.401.79

1.111.091.542.52

787925

13041866

867103114102053

261-65-4404� 261-65-4408� 261-65-4412

48

12

608080

0.610.791.00

0.290.490.79

252478674

291542754

261-65-4416261-65-4424261-65-4436

162436

808080

1.121.501.71

0.991.772.30

85812451761

96413881948

261-60-5502261-60-5504261-60-5508

14 (7x)

248

456080

0.510.680.91

0.210.360.65

147272511

163311575

261-60-5510261-60-5512261-60-5516 •

101216

808080

1.061.091.20

0.880.931.13

627721919

707801

1025

261-60-5520 •261-60-5524 •261-60-5536 •261-60-5550 •

20243650

808080

110

1.341.481.672.02

1.411.722.193.20

1120132218862681

1226142820292973

261-65-5504261-65-5512

412

6080

0.751.23

0.441.19

351954

3901060

261-65-5516 •261-65-5524 •261-65-5536 •

162436

8080

110

1.361.692.00

1.452.243.14

122517942683

133119872975

• Contains 41-strand tinned copper overall drain wire, same size as conductor.

� Cross-sectional area for calculation of cable tray fill inaccordance with NEC Section 392.22

Length Tolerance: Cut lengths of 1000 feet or longer aresubject to a tolerance of � 10%; less than 1000 feet � 15%.

� Authorized Stock Item: Available from our Customer Service Centers.

M/21020531

Okoseal-N Type SP-OSUL Type TC and cUL Type CIC Instrumentation CableSingle Pairs or Triads - Individual and Overall Shield600V - 90°C Rating Wet or Dry

Product DataSection 5: Sheet 31

ELECTRICAL SPECIFICATIONSPer UL Standard 1277

Conductor Resistance, maximum ........ohms/1000 ft................................................................... @20°C @25°C

18 AWG ................................................ 6.09 7.0416 AWG ................................................ 4.34 4.4314 AWG ................................................ 2.72 2.78

Insulation Test Voltage (spark test)18 - 16 AWG .................... 6000 VOLTS AC14 AWG ........................... 7500 VOLTS AC

Dielectric Test Voltage ...............2000 Volts ac for 1 minuteInsulation Resistance Constant @ 60F, minimum

(natural material typical value) ............ 2000 ohms/1000 ft.Loop Resistance, maximum (2 conductor)ohms-1000 ft.................................................................. @20°C @25°C

18 AWG............................................... 12.18 14.0816 AWG ............................................... 8.68 8.8614 AWG .............................................. 5.44 5.56

Cross

-Sec

tional

Area �

(sq

in)

Number

of Triads

SizeAW

GStra

nds

Catalo

gNum

ber

Number

of Pairs

Approx Net

Weig

ht

(lbs/1

000’)

Approx Ship

Weig

ht

(lbs/1

000’)

Nomin

alCab

le

O.D. -

(In.)

Jack

etThick

ness-

(mils

)

THE OKONITE COMPANYRamsey, New Jersey 07446

ULR c ULR

C-L-X Okoseal-N P-OS® ®

UL Type MC-HL and cUL Type ACIC-TC Instrumentation CableSingle Pair or Triad-Overall Shield600 Volts 90°C Rating 600/1000V Marine CableFor Cable Tray Use - Sunlight Resistant - For Direct Burial

A Bare Stranded Copper ConductorOkoseal Insulation/Nylon JacketBTwisted, Shielded Pairs/TriadsCTinned Stranded Copper Drain WireDAluminum/Synthetic Polymer TapeERip CordF

G Inner Black Okoseal JacketImpervious, Continuous, CorrugatedHAluminum C-L-X SheathOuter Black Okoseal JacketJ

Product DataSection 5: Sheet 40

OK

ON

ITE

SP

-OS

12

PR

16

AW

G C

U X

-OL

EN

E (

XL

PE

)

SpecificationsConductors: Bare soft annealed copper,

Class B, 7-strand concentric per ASTM B-8.

Insulation: Flame-retardant Okoseal (PVC)

per UL 83, 15 mils nominal thickness, 90°C

temperature rating.

Jacket: Nylon per UL 83, 8 mils nominal

thickness.

Conductor Identification: Pigmented black

and white in pairs; black, white and red in

triads.

Assembly: Pairs or triads assembled with

left-hand lay. Non-wicking fillers included

where required to provide a round cable.

Cable Shield: Aluminum/Polyester tape

overlapped to provide 100% coverage, and a

#16 AWG stranded tinned copper drain wire.

Inner Jacket: Black, flame-retardant Okoseal

per UL Standard 1569. A rip cord is laid

longitudinally under the jacket to facilitate

removal.

C-L-X Sheath: A close-fitting, impervious,

continuously welded and corrugated,

aluminum sheath meeting UL 1569 provides

complete protection against moisture, liquids,

and gases, has excellent mechanical

strength, and provides equipment grounding

through the sheath.

Outer Jacket: Black, flame-retardant

Okoseal per UL Standard 1569.

ApplicationsOkonite C-L-X Single pair or triad type P-OS

instrumentation cables are designed for use

on Class 1 Remote-Control Signaling circuits

or where a 600V cable is desired, as

instrumentation, process control, or computer

cable transmitting signals at levels above 100

milli-volts in circuits where shielding against

external interference is required, but

shielding against interference among groups

is not required. For use indoors or outdoors;

wet or dry locations; in cable trays; in

raceways; supported by a messenger wire;

for direct burial; in Classes I, II, and III,

Divisions 1 and 2 hazardous locations per

NEC Articles 501, 502, 503, 504 and 505; in

Zone 2, Class II Div 2, Class III Div 1 and

Class III Div 2 per CEC.

The overall shield eliminates most of the

static interference from the electric field

radiated by power cables and other electrical

equipment.

The C-L-X sheath provides the physical

protection against mechanical damage as

required in NEC Section 725-8 as well as

complete protection against moisture or

gases entering the cable.

UL® c UL®

OK

ON

ITE

6 P

-OS

1 P

R 1

6A

WG

CU

X-O

LE

NE

(X

LP

E)

E

AB

C

D

FG

H

J

P-O

S 1

PR

16

AW

G C

U P

VC

-N P

VC

(U

L)

For dc service in wet locations, X-Olene

insulation is recommended.

These cables also comply with UL requirements

for Types CL2 and CL3.

Product FeaturesComplete pre-packaged, factory-tested wiring

system—color coded.

C-L-X enclosure permits installation in cable

tray containing light and power cables without a

barrier separator.

Impervious, continuous sheath excludes

moisture, gases and liquids.

Excellent compression and impact resistance.

Lower installed system cost than conduit or

EMT systems.

Suitable for low temperature installation to

-40°C.

Applicable Standards• UL listed for cable tray use, direct burial andsunlight resistant.

• Vertical Tray Flame Tests.IEEE 383-1974, FT4/IEEE 1202,ICEA T-29-520 (210,000 BTU)

• American Bureau of Shipping Type approvedas CWCMC Type MC-HL.

• API Standards 14F and 14FZ.

• ASTM B-8.

• OSHA Acceptable

• UL 2225 Type MC-HL

• UL 83

• UL 1309 (CWCMC) Marine Shipboard

• UL 1569

• UL certified as Marine Shipboard in accordwith IEEE 1580, Marine Shipboard Cable rated600/1000 volts.

• NEC Articles 501, 502, 503, 504 and 505 forClasses I, II and III, Divisions 1 and 2Hazardous Locations.

• NPLF per NEC Code Article 760.

• CSA C22.2 No. 230 Type TC

• CSA C22.2 No. 239 Type ACIC

• cUL Type ACIC-TC complies with CEC Zone2, Class II Div 2, Class III Div 1 and Class III Div2 Hazardous Locations.

Product DataSection 5: Sheet 40

O/20090540

THE OKONITE COMPANYRamsey, New Jersey 07446

Inner J

acket

Thickness-m

ils

Catalo

gNum

ber

Number of P

airs

Cross-S

ectional

Area* S

q. in.

Net Weig

ht

Lbs./1000’

ShipW

eight

Lbs./1000’

Number o

f Tria

ds

#16 AWG - Single Pair & Triad (P-OS) Type MC-HL

▲ Available from our Customer Service Centers.Authorized Stock Item.area for calculation of cable tray fill in accordance with* Cross-sectional

NEC Section 392.22.Optional jacket types available - consult local sales office.Jackets:

C-L-X available on special order.Copper or bronzeC-L-X Type P-OS without the outer Okoseal jacket (not “HL” listed),To Order

change the sixth digit of the catalog number from 3 to 1, for example to order1 pr. 20 AWG with a bare aluminum C-L-X, the catalog number would be 564-10-1212.

Cut lengths of 1000 ft. or longer are subject to a tolerance of + \ -10%;Length Tolerance:less than 1000 feet + \ -15%.

ELECTRICAL SPECIFICATIONS

Conductor Resistance, maximum..............................ohms/1000 ft....................................................................................@20°C @25°C16 AWG ....................................................................4.34............4.43

Insulation Test Voltage (spark test)....................................6000 Volts acDielectric Test Voltage .......................................................2000 Volts acShield Isolation Test

Pair to Cable Shield............................exceeds 100 Megohms-1000 ft.Insulation Resistance Constant @60°F minimum

(natural material typical value................2000 Ohms-1000 ft.Loop Resistance, nominal (2 conductors).............ohms/1000 ft...............................................................................@20°C.............@25°C16 AWG ...............................................................8.68..................8.86

Mutual Capacitance (PF/ft.)*#16.......................................................................60

*Typical Value

UL® c UL®

C-L-X Okoseal-N P-OSUL Type MC-HL and cUL Type ACIC-TC Instrumentation CableSingle Pair or Triad-Overall Shield600 Volts 90°C Rating 600/1000V Marine CableFor Cable Tray Use - Sunlight Resistant - For Direct BurialConductors: #16 AWG; Okoseal Insulation: 15 mils: Nylon Jacket: 8 mils

▲564-60-3401▲564-65-3401

564-60-3403

11

3

66 .3558 .3540 .45

.53 50 .64

.53 50 .64

.67 50 .78

0.320.320.48

182 221190 229247 640

Inner J

acket

Nomin

al O.D

. - in

ches

C-L-X

O.D

. - in

ches

Outte

r Jacket

Thickness-m

ils

Nomin

al Jacket

O.D

. - in

ches

SpecificationsConductors: Bare soft annealed copper, Class B,7-strand concentric per ASTM B-8.Insulation: Flame-retardant Okoseal (PVC) perUL 83, 15 mils nominal thickness, 90°C tem-perature rating.Insulation Jacket: Nylon per UL 83, 4 mils nominalthickness.Conductor Identification: Pigmented black andwhite in pairs, black, white and red in triads.Group Shield: Aluminum polyester tape over-lapped to provide 100% coverage, and a 7-strandtinned copper drain wire, two sizes smaller thanthe conductor. All group shields are completelyisolated from each other.Assembly: Pairs or triads assembled with left-handlay. Non-wicking fillers included where required toprovide a round cable.Cable Shield: Aluminum/polyester tape over-lapped to provide 100% coverage, and a 7-strandtinned copper drain wire, same size as conductor.Inner Jacket: Black, flame-retardant Okoseal perUL Standard 1569. A rip cord is laid longitudinallyunder the jacket to facilitate removal.C-L-X Sheath: A close-fitting, impervious, contin-uously welded and corrugated, aluminum sheathprovides physical protection against mechanicaldamage as required in NEC Section 725-8.Additionaly, C-L-X meets UL 1569 provides com-plete protection against moisture, liquids, andgases, has excellent mechanical strength, andprovides equipment grounding through the sheath.Outer Jacket: Black, flame-retardant Okoseal perUL Standard 1569.Classifications: UL Listed as Type MC-HL Arti-cles 501, 502, and 503 of the National ElectricalCode.

ApplicationsOkonite C-L-X type SP-OS (shielded pairs or tri-ads - overall shield) instrumentation cables aredesigned for use on Class 1 Remote-Control Sig-naling circuits or where a 600V cable is desired,as instrumentation, process control, or computercable transmitting signals at levels above 100mili-volts in circuits where maximum noise protec-tion is required. Protection from interferenceamong groups as well as external sources is pro-vided by individual group shields as well as anoverall cable shield. For use indoors or outdoors;wet or dry locations; in cable trays’ in raceways;supported by a messenger wire; for direct burial;in Classes I, II, and III, Divisions 1 and 2 andClass I, Zones 1 and 2 hazardous locations perNEC Articles 501, 502, 503 and 505; in Zone 2,

Class II Div 2, Class III Div 1 and Class III Div2 per CEC.The isolated individual shields over eachpair, when properly grounded, preventcrosstalk or capacitive coupling betweenadjacent pairs which occurs with ac signals,particularly the pulse type.The overall shield eliminates most of the staticinterference from the electric field radiated bypower cables and other electrical equipment.The C-L-X sheath provides physical protectionagainst mechanical damage as required inNEC Section 725-8 as well as complete pro-tection against moisture or gases entering thecable.For dc service in wet locations, X-Olene insu-lation is recommended.

Product FeaturesIndividual units are completely isolated formaximum noise rejection.C-L-X enclosure permits installation in cabletray containing light and power cables withouta barrier separator.Lower installed system cost than conduit orEMT systems.Suitable for low temperature installation to-40°C.

Applicable Standards• UL listed for cable tray use, direct burial, inducts, and sunlight resistant.• Vertical Tray Flame Tests;IEEE 383-1974, FT4/ IEEE 1202, ICEAT-29-520 (210,000 BTU).• American Bureau of Shipping Type approvedas CWCMC Type MC-HL.• API Standards 14F and 14FZ.• ASTM B-8• OSHA Acceptable• UL 2225 Type MC-HL, UL 83, UL 1309(CWCMC) Marine Shipboard, UL 1569• UL certified to IEEE 1580 - Marine Ship-board Cable rated 600/1000V.• NEC Articles 501, 502, 503, 504 and 505 forClasses I, II, and III, Divisions 1 and 2 Hazard-ous Locations.• NPLF pr NEC Code Article 760.• CSA C22.2 No. 230 Type TC• CSA C22.2 No. 239 Type ACIC• cUL Type ACIC-TC Complies with CECZone 2, Class II Div 2, Class III Div 1, Class IIIDiv 2 Hazardous Locations.

C-L-X® Okoseal-N® SP-OSUL Type MC-HL and cUL Type ACIC-TC Instrumentation CableMultiple Shielded Pairs or Triads - Individual and Overall Shield600 Volts 90°C Rating MC-HL — 600/1000V Marine CableFor Cable Tray Use - Sunlight Resistant - For Direct Burial

Product DataSection 5: Sheet 42

A Bare Stranded CopperConductor

B Okoseal Insulation/Nylon JacketC Tinned Stranded Copper Group

Drain WireD Aluminum/Polyster TapeE Twisted, Shielded Pairs/TriadsF Tinned Stranded Copper Drain WireG Aluminum/Polyester TapeH Rip CordJ Inner Black Okoseal JacketK Impervious, Continuous, Corrugated

Aluminum C-L-X SheathL Outer Black Okoseal Jacket

SP

-OS

24P

R16

AW

GC

UP

VC

-NP

ULR c ULR

� 561-60-3402561-60-3403

� 561-60-3404561-60-3406

2346

40405050

0.450.490.560.66

0.670.700.800.89

50505050

0.760.820.911.00

0.450.530.650.79

234278335421

314369415501

� 561-60-3408561-60-3410

� 561-60-3412

81012

505050

0.700.790.85

0.931.061.11

505050

1.041.171.22

0 .851.081.17

492601674

572681780

561-60-3416561-60-3420

�561-60-3424

162024

505050

0.981.061.12

1.291.341.42

505050

1.401.451.53

1.541.651.84

842977

1118

94811201261

� 561-60-3436561-60-3450

3650

5050

1.371.57

1.691.92

6060

1.822.05

2.603.30

15862124

17732416

561-65-3402� 561-65-3404� 561-65-3408� 561-65-3412

24812

40505050

0.490.610.820.98

0.710.841.061.29

50505050

0.820.951.171.40

0.530.711.081.54

272395637863

439475717969

561-65-3416561-65-3424561-65-3436

162436

505050

1.101.331.58

1.371.641.96

506060

1.481.782.09

1.722.493.43

105814852141

120116722426

� Authorized Stock Item: Available from our Customer Service Centers.

*Cross-sectional area for calculation of cable tray fill in accordance withNEC Section 392.22.

Jackets - Optional jacket types available - consult local sales office.

Copper or bronze C-L-X available on special order.

To order C-L-X Type SP-OS without the outer Okoseal jacket (not “HL”listed), change the sixth digit of the catalog number from 3 to 1, for exam-ple to order 1 pr. 20 AWG with a bare aluminum C-L-X, the catalog numberwould be 564-10-1212.

Length Tolerance: Cut lengths of 1000 ft. or longer are subject to a toler-ance of � �\ 10%; less than 1000 ft. � �\ 15%

O/20050542

C-L-X Okoseal-N SP-OSUL Type MC-HL and cUL Type ACIC-TC Instrumentation CableMultiple Shielded Pairs or Triads - Individual and Overall Shield600V 90°C Rating MC-HL — 600/1000V Marine CableFor Cable Tray Use - Sunlight Resistant - For Direct BurialConductors: #16 AWG; Okoseal Insulation: 15 mils: Nylon Jacket: 4 mils

Product DataSection 5: Sheet 42

ELECTRICAL SPECIFICATIONSConductor Resistance, nominal ........................ohms/1000 ft. @20°C

16 AWG......................................................................4.1Insulation Test Voltage (spark test) ...............................6000 Volts acDielectric Test Voltage .................................2000 Volts ac for 60 sec.Insulation Resistance Constant @60°F minimum

(natural material typical value) ..2000 Megohms-1000 ft.Loop Resistance, nominal (2 conductor)............ohms-1000 ft @20°C

16 AWG......................................................................8.2Mutual Capacitance (PF/ft.)*

#16 ..............................................................................60*Typical Value

Nomin

alCab

le

O.D. -

Inch

es

Number

of Triads

Number

of Pairs

Inner

Jack

et

Thicknes

s - mils

Nomin

alCore

O.D. -

Inch

es

Outer Ja

cket

mils

C-L-X

O.D. -

Inch

es

ShipW

eight

Lbs./10

00’

Cross

-Sec

tional

Area*

Sq. In.

NetW

eight

Lbs./10

00’

Catalo

gNum

ber

THE OKONITE COMPANYRamsey, New Jersey 07446

ULRc ULR

#18 AWG tinned copper,Class M, stranded per ASTM B-174.

Okolene® (Polypropylene)per UL 13 and 2250, 32 mils nominalthickness, 75°C temperature rating.

Pigmented or-ange and blue in pairs, orange conductornumerically printed for group identification.

Aluminum/Polyester tapeoverlapped to provide 100% coverage,and a Class M tinned copper drain wire,two sizes smaller than the conductor. Allmulti-pair shields are isolated from eachother.

Pairs assembledwith a left-hand lay. Cable fillers includedwhere required to provide a round cable.

Alumi-num/Polyester tape overlapped to provide100% coverage, and a class M strandtinned copper drain wire, same size asconductor.

Orange, flame-retardant, Okosealper UL 13 and 2250. A rip cord is laid lon-gitudinally under the jacket to facilitateremoval.

UL Listed asPLTC-Power Limited Tray Cable and asITC-ER - Instrument Tray Cable/ExposedRun for use in accordance with Article 727and Article 725 of the National ElectricalCode.

Cables comply with ISA-S-50-02, UL 2250and UL 13 for Fieldbus circuits and CL2and CL3.

Okonite® OKOBUS® cables are designedfor use in rugged plant environments utiliz-ing networked discrete or processautomation and control. ITC-ER (Instru-ment Tray Cable - Exposed Run)eliminated the need for conduit when in-stalled in accordance with NEC Article727.4(6). Fully complies with ANSI/ISA50.02 part 2 for Fieldbus Cable.

The isolated individual shields overeach pair, when properly grounded,

prevent crosstalk or capacitive cou-pling between adjacent pairs whichoccurs with ac signals, particularlythe pulse type.

The overall shield or multi pair cableseliminates most of the static interferencefrom the electrical field radiated by powercables and other electrical equipment.

• Passes the UL 13 and IEEE 383 verticaltray flame tests.

• Single pair passes IEEE 1202 verticaltray flame test.

• Sunlight & oil resistant.

• UL listed for direct burial.

• Individual pairs are completely isolated.

• 100% shield coverage for reduced elec-tromagnetic noise pick-up.

• Excellent external noise rejection.

• Excellent weathering characteristics.

• OSHA Acceptable.

• Flexible, easy to handle and terminate.

Tinned Copper StrandedConductorPolypropylene InsulationTinned Stranded Copper GroupDrain WireAluminum/Polyester TapeTwisted, Shielded PairsAluminum/Polyester TapeTinned Stranded Copper DrainWireRip CordOrange Okoseal Jacket

Okobus

Single Pair or Multiple Shielded Pairs - Overall Shield300 Volts 75°C Rating

ULR

� 264-92-3901261-92-3302

12

4550

0.340.55

0.090.24

62148

73172

261-92-3304261-92-3063

46

6060

0.710.80

0.400.50

212264

251303

261-92-3308261-92-3312261-92-3316

81216

707070

0.911.041.17

0.650.851.08

340474580

404554660

261-92-3320261-92-3324

2024

8080

1.321.46

1.371.67

722880

8281023

� area for calculation of cabletray fill in accordance with NEC Section 392.22

Cut lengths of 1000 feet orlonger are subject to a tolerance of � 10%; lessthan 1000 feet � 15%.

� Available from ourCustomer Service Centers.

E/13110547

ULR

Okobus

Single Pair or Multiple Shielded Pairs - Overall Shield 300 V 75°C Rating

a) Characteristic Impedance, zo, at fr(31.25kHz), minimum ........................100 ohms

b) Maximum attenuation at1.25 fr (39 kHz)..................................3.0 dB/km

c) Maximum capacitive unbalanceto shield...............................................2 nF/km

d) Maximum DC resistance(per conductor) ................................24 ohms/km

e) Maximum propagation delaychange 0.25 fr to 1.25 fr.....................1.7 �s/km

f) conductor cross-sectional area nominal(wire size) ..................................0.8 mm2 (#18 AWG)

g) Minimum shield coverage.....................100%

THE OKONITE COMPANYRamsey, New Jersey 07446

SpecificationsConductors: #18 AWG tinned copper,Class M, stranded per ASTM B-174.

Insulation: Okolene® (Polypropylene)per UL 13 and 2250, 32 mils nominalthickness, 75°C temperature rating.

Conductor Identification: Pigmented or-ange and blue in pairs, orange conductornumerically printed for group identification.

Pair Shield: Aluminum/Polyester tapeoverlapped to provide 100% coverage,and a Class M tinned copper drain wire,two sizes smaller than the conductor. Allmulti-pair shields are isolated from eachother.

Multiple Pair Assembly: Pairs assembledwith a left-hand lay. Cable fillers includedwhere required to provide a round cable.

Multiple Pair Cable Shield: Alumi-num/Polyester tape overlapped to provide100% coverage, and a class M strandtinned copper drain wire, same size asconductor.

Inner Jacket: Orange, flame-retardant,Okoseal per UL 13 and 2250. A rip cord islaid longitudinally under the jacket to facili-tate removal.

C-L-X Sheath: A close-fitting, impervious,continuously welded and corrugated, alu-minum sheath provides completeprotection against moisture, liquids, andgases, has excellent mechanical strength,and provides equipment groundingthrough the sheath.

Outer Jacket: Orange, flame-retardant,Okoseal per UL 13 and 2250.

Classifications: UL Listed asPLTC-Power Limited Tray Cable and asITC-HL - Instrument Tray Cable/Hazard-ous Locations for use in accordance withArticle 727 and Article 725 of the NationalElectrical Code.

Cables comply with ISA-S-50-02, UL 2250and UL 13 for Fieldbus circuits and CL2and CL3.

ApplicationsC-L-X OKOBUS® cables are designed foruse in rugged plant and off-shore marine

environments utilizing networked discreteor process automation and control.ITC-HL (Instrument Tray Cable - Hazard-ous Locations) eliminates the need forconduit when installed in accordancewith NEC Article 501.10(A)(1)(4)"ITC-HL" installations. Fully complieswith ANS/ISA 50.02 Part 2 FieldbusCable.

The isolated individual shields overeach pair, in SP-OS cables, whenproperly grounded, prevent crosstalkor capacitive coupling between adja-cent pairs which occurs with acsignals, particularly the pulse type.

The overall shield eliminates most of thestatic interference from the electrical fieldradiated by power cables and other elec-trical equipment.

The C-L-X sheath provides additionalelectrical shielding and physical protec-tion against mechanical damage as wellas complete protection against moistureor gases entering the cable.

Product Features• Passes the UL 13 and IEEE 383 verticaltray flame tests.

• Passes IEEE 1202 vertical tray flametest.

• Sunlight & oil resistant.

• UL listed for direct burial.

• Complete pre-packaged, factory-testedwiring system-color coded.

• C-L-X enclosure permits installation incable tray containing lighting and power ca-bles without a barrier separator.

• Individual pairs are completely isolated.

• Impervious, continuous sheath excludesmoisture, gases and liquids.

• In addition, the aluminum CLX sheathexceeds the equipment grounding require-ments of NEC Section 250.118 and250.122, and can be used as the equip-ment grounding conductor in non-HLareas.

• Lower installed system cost than conduitor EMT systems.

A Tinned Copper StrandedConductor

B Polypropylene InsulationC Tinned Stranded Copper Group

Drain WireD Aluminum/Polyester TapeE Twisted, Shielded PairsF Aluminum/Polyester TapeG Tinned Stranded Copper Drain

WireH Rip CordJ Inner Orange Okoseal JacketK Impervious, Continuous, Corrugated

Aluminum C-L-X SheathL Outer Orange Okoseal Jacket

Product DataSection 5: Sheet 48

Okobus C-L-XSingle Pair: Type P-OS - Multi Pair: Type SP-OSType PLTC & Type ITC-HL Fieldbus CableSingle Pair or Multiple Shielded Pairs - Overall Shield300 Volts 75°C Rating

ULR

� 564-92-3301561-92-3302

12

4550

0.340.55

0.530.80

4050

0.620.91

0.300.65

155311

194391

561-92-3304561-92-3306

46

6060

0.710.81

0.931.06

5050

1.041.17

0.851.08

400493

480573

561-92-3308561-92-3312561-92-3316

81216

707070

0.911.041.17

1.151.341.47

505050

1.261.451.58

1.251.651.96

587759902

693902

1045

561-92-3320561-92-3324

2024

8080

1.331.46

1.641.78

5050

1.751.89

2.412.81

10721308

12361495

� Cross-sectional area for calculation of cable tray fillin accordance with NEC Section 392.22.Copper or bronze C-L-X available on special order.Length Tolerance: Cut lengths of 1000 feet or longerare subject to a tolerance of � 10%; less than 1000feet � 15%.� Authorized Stock Item: Available from our Cus-tomer Service Centers.

G/20020548

ULR

Okobus — C-L-XSingle Pair Type P-OS - Multi Pair Type SP-OSType PLTC & Type ITC-HL Fieldbus CableSingle Pair or Multiple Shielded Pairs - Overall Shield 300 V 75°C Rating#18 AWG

Product DataSection 5: Sheet 48

Cross

-Sec

tional

Area �

(sq

in)

Inner

Jack

et

Thicknes

s - mils

Nomin

alCore

O.D. In

ches

Outer Ja

cket

mils

C-L-X

O.D. In

ches

Catalo

gNum

ber

Number

of Pairs

Approx Net

Weig

ht

(lbs/1

000’)

Approx Ship

Weig

ht

(lbs/1

000’)

Nomin

alCab

le

O.D. -

Inch

es

CHARACTERISTICS

a) Characteristic Impedance, Zo, at fr(31.25kHz), minimum ............................100 ohms

b) Maximum attenuation at1.25 fr (39 kHz)......................................3.0 dB/km

c) Maximum capacitive unbalanceto shield...................................................2 nF/km

d) Maximum DC resistance(per conductor) ....................................24 ohms/km

e) Maximum propagation delaychange 0.25 fr to 1.25 fr.........................1.7 �s/km

f) conductor cross-sectional area nominal(wire size) ......................................0.8 mm2 (#18 AWG)

g) Minimum shield coverage .........................100%

THE OKONITE COMPANYRamsey, New Jersey 07446

SpecificationsConductors: Bare copper, Class B,stranded per ASTM B8.

Insulation: X-Olene� (XLPE), per UL 13,2250 & 1569, 30 mils nominal thickness,90°C temperature rating. MeetsMIL-DTL-1377H, section 4.8.4.1.2 ColdBend at -66°C and ASTM D746-04brittlepoint at -76°C.

Conductor Identification: Pigmentedblack and white in pairs, black, red andwhite in triads; white conductor numericallyprinted for group identification.

Pair Shield: Aluminum/Polyester tapeoverlapped to provide 100% coverage, anda Class B tin coated copper drain wire, twosizes smaller than the conductor. Allmulti-pair shields are isolated from eachother.

Multiple Pair Assembly: Pairs/triads as-sembled with a left-hand lay. Cable fillersincluded where required to provide a roundcable.

Multiple Pair Cable Shield: Alumi-num/Polyester tape overlapped to provide100% coverage, and a class B strand tincoated copper drain wire, same size asconductor.

Inner Jacket: Black, flame-retardant, lowtemperature Okoseal® (PVC) per UL 13and UL 2250. The inner jacket meets thethickness requirements of UL 1277. A ripcord is laid longitudinally under the jacketto facilitate removal.

C-L-X Sheath: A close-fitting, impervious,continuously welded and corrugated, alu-minum sheath provides completeprotection against moisture, liquids, andgases, has excellent mechanical strength,and provides equipment grounding throughthe sheath.

Outer Jacket: Black, flame-retardant, lowtemperature Okoseal per UL 13 and UL2250.

ApplicationsITC-HL and MC-HL cables eliminate theneed for conduit when installed in accor-dance with NEC Article 501.10(A)(1)(4)"ITC-HL" or 501.10(A)(1)(3) "MC-HL" in-stallations. UL listed as PLTC-PowerLimited Tray Cable and as ITC-HL - Instru-ment Tray Cable/Hazardous Locations foruse in accordance with Article 725 (Class1, 2 & 3) and Article 727 of the NationalElectrical Code.

UL listed as MC-HL for use in Class I, II, andIII, Divisions 1 and 2 hazardous location in ac-cordance with NEC Articles 501, 502, 503, 504& 505; in Zone 2, Class II Div 2, Class III Div 1and Class III Div 2 per CEC.

The isolated individual shields over each pair, inSP-OS cables, when properly grounded, pre-vent crosstalk or capacitive coupling betweenadjacent pairs while the overall shield elimi-nates most of the static interference from theelectrical field radiated by power cables andother electrical equipment.

Product FeaturesComplete pre-packaged, factory-tested wiringsystem-color coded.C-L-X enclosure permits installation in cabletray containing lighting and power cables with-out a barrier separator.Lower installed system cost than conduit orEMT systems.

Applicable Standards• UL listed for cable tray use, direct burial, inducts, and sunlight resistant.

• Vertical Tray Flame Tests;IEEE 383-1974 & FT4/IEEE 1202.

• UL listed at -50°C. Also, meets the CSA 22.2No.3 Cold Impact Test at -45°C.

• API Standards 14F and 14FZ.

• ASTM B8.

• OSHA Acceptable

• UL 2225 Type MC-HL & UL 1569

• NEC Articles 501, 502, 503, 504 and 505 forClasses I, II, and III, Divisions 1 and 2 HazardousLocations.

• UL listed as PLTC-Power Limited Tray Cableand as ITC-HL - Instrument Tray Cable/Hazard-ous Locations for use in accordance with Article725 (Class 1, 2 & 3) and Article 727 of the Na-tional Electrical Code.

• NPLF per NEC Code Article 760.

• CSA C22.2 No. 230 Type TC

• CSA C22.2 No. 239 type ACIC

• cUL listed as Type ACIC-TC complies with CECZone 2, Class II Div 2, Class III Div 1, Class III Div2 Hazardous Locations.

Product DataSection 5: Sheet 49

C-L-X� X-Olene� SP-OSUL Type MC-HL, PLTC, ITC-HL and cUL ACIC-TC Instrumentation CableMultiple Shielded Pairs/Triads - Overall Shield600 Volts 90°C Rating: UL MC-HL and cUL ACIC-TC300 Volts 90°C Rating: UL PLTC & ITC-HLFor Cable Tray Use Sunlight Resistant For Direct Burial -50°C

A Copper Stranded ConductorB X-Olene InsulationC Tin Coated Copper Group

Drain WireD Aluminum/Polyester TapeE Twisted, Shielded PairsF Aluminum/Polyester TapeG Tin Coated Copper Drain

WireH Rip CordJ Inner Okoseal JacketK Impervious, Continuous, Corrugated

Aluminum C-L-X SheathL Outer Okoseal Jacket

ULR c ULR

567-70-3302567-70-3304567-70-3308567-70-3312567-70-3324567-70-3336

248

122436

45 0.5060 0.6760 0.8380 1.0080 1.3480 1.55

0.71 50 0.820.89 50 1.001.06 50 1.171.29 50 1.401.64 60 1.781.92 60 2.05

0.530.791.081.542.483.29

253365503693

11251545

333445583799

12901835

567-71-3302567-71-3304567-71-3308567-71-3312567-71-3324

248

1224

60 0.6260 0.7380 0.9880 1.1580 1.58

0.84 50 0.950.97 50 1.081.24 50 1.351.47 50 1.581.96 60 2.09

0.710.921.431.963.42

326428658860

1505

406508764

10031760

� Cross-sectional area for calculation of cable tray fill inaccordance with NEC Section 392.22.Jackets - Optional jacket types available - consult localsales office.Copper or bronze C-L-X available on special order.To order without the outer Okoseal jacket (not "HL" listed),change the sixth digit of the catalog number from 3 to 1, forexample to order 2 pr. 16 AWG with a bare aluminum C-L-X,the catalog number would be 567-70-1402.Length Tolerance: Cut lengths of 1000 feet or longer aresubject to a tolerance of � 10%; less than 1000 feet � 15%.

K/21050549

C-L-X� X-Olene� SP-OSUL Type MC-HL, PLTC, ITC-HL and cUL ACIC-TC Instrumentation CableMultiple Shielded Pairs/Triads - Overall Shield600 Volts 90°C Rating: UL MC-HL and cUL ACIC-TC300 Volts 90°C Rating: UL PLTC & ITC-HLFor Cable Tray Use Sunlight Resistant For Direct Burial -50°C

Product DataSection 5: Sheet 49

Cross

-Sec

tional

Area �

(sq

in)

Inner

Jack

et

Thicknes

s - mils

Nomin

alCore

O.D. In

ches

Outer Ja

cket

mils

C-L-X

O.D. In

ches

Catalo

gNum

ber

Number

of Triads

Approx Net

Weig

ht

(lbs/1

000’)

Approx Ship

Weig

ht

(lbs/1

000’)

Nomin

alCab

le

O.D. -

Inch

es

ELECTRICAL SPECIFICATIONS

Conductor Resistance, nominal - ohms/1000 ft......@20°C ..........@25°C16 AWG ................................................................4.34 .................4.4318 AWG ................................................................6.93 .................7.07

Insulation Test Voltage (spark test) ....................................7500 Volts ac

Dielectric Test Voltage .......................................................3000 Volts ac

Insulation Resistance Constant @60°F minimum ...10,000 ohms-1000 ft.

Loop Resistance, nominal (2 cdr.) - ohms/1000 ft .@20°C ..........@25°C16 AWG .................................................................8.68 .................8.8618 AWG .................................................................13.9 .................14.2

Mutual Capacitance (PF/ft.)*#16 ....................................................................................................23#18 ....................................................................................................21

*Typical Value

THE OKONITE COMPANYRamsey, New Jersey 07446

#16 AWG567-70-3402567-70-3404567-70-3408567-70-3412567-70-3424567-70-3436

248

122436

60 0.5860 0.7080 0.9280 1.1080 1.44

110 1.82

0.80 50 0.910.93 50 1.041.19 50 1.301.37 50 1.481.78 60 1.912.19 60 2.32

0.650.851.331.732.874.23

325 405424 504650 752842 985

1450 16402145 2480

567-71-3402567-71-3404567-71-3408567-71-3412567-71-3424

248

1224

60 0.6460 0.7580 1.0680 1.2680 1.65

0.89 50 1.001.02 50 1.131.34 50 1.451.56 60 1.692.01 60 2.14

0.791.001.642.243.61

376 456500 580800 945

1090 12351914 2199

#18 AWG

Number

of Pairs

ULRc ULR

X-Olene Okoseal® ®

UL Type TC-ER/ITC -ER and cUL Type CIC-TC*or Oko-Marine Cable600 Volt Instrumentation/Signal Cable600/1000V Marine Shipboard CableSingle Pair/Triads or Multiple Pairs/Triads Type P-OSFor Cable Tray Use - Sunlight Resistant - For Direct Burial*cUL CIC-TC-ER sizes 14 AWG & larger

A Copper Strand ConductorX-Olene InsulationB

C Tinned Stranded Copper Drain WireD Aluminum/Polyester TapeE Twisted PairsF Rip CordG Okoseal Jacket

Product DataSection 5: Sheet 50

triads; white conductor numerically printed

for group identification.

Cable Shield: Aluminum/Polyester tape

overlapped to provide 100% coverage, and

a tinned copper. Class M drain wire same

size as conductor. All multi-unit shields are

isolated from each other.

Multiple Unit Assembly: Pairs/Triads

assembled with a left-hand lay. Cable

fillers, included where required, providing a

round cable.

Jacket: Black Okoseal jacket. Complies

with UL 1277, UL 1309 & IEEE 1580 PVC,

Type T, thermoplastic polyvinyl chloride

jacket.

UL Listed as Type TC-ER cable with a

sunlight resistant jacket and for direct

burial.

UL Listed as Type OKO-MARINE signal

cable to the requirements of UL 1309. Also,

UL certified as meeting the requirements of

IEEE 1580 — Marine Cable.

Product Features• For cable tray use and direct burial.• Sunlight resistant.• Insulated conductors are UL rated 90°Ccontinuous rating in wet or dry locations.• Flame Retardant - passes the vertical trayflame test requirements of IEEE 383-1974& 1202-2010 and UL 1277.

• X-Olene Okoseal Type TC-ER/ITC-ER

cables are quality control inspected to meet

or exceed applicable industry standards.

• Resistant to moisture and most chemical

atmospheres.

• Thermal stability at elevated

temperatures.

• CSA C22.2 No. 239 & 230 Type

CIC-TC-ER*.

• CSA C22.2 No. 245 Type Marine

Shipboard.

• Passes -40°C cold bend test.

InsulationX-Olene is Okonite's trade name for

®

its cross-linked polyethylene

insulation, with high dielectric strength.

Cable JacketThe Okoseal (PVC) jacket supplied

with this cable is mechanically rugged

and has excellent resistance to acids

and most chemicals and is rated for

low temperature installations.

ApplicationsX-Olene Okoseal 600 volt shielded

instrumentation cables are designed

for use in rugged plant environments,

such as Offshore Rig Projects, on

Class 1 Remote-Control Signaling

circuits or where a 600V

instrumentation or control cable is

desired.They are designed for use

indoors or outdoors; wet or dry

locations; in cable trays; in raceways;

supported by a messenger wire; and

for direct burial. Can be installed as

Type TC/ITC in Class I, Division 2;

Class II, Division 2; Class III, Division

1; and Zone 2 hazardous locations in

accordance with NEC Articles 501.10,

502.10, 503.10, and 505.15.

TC-ER (Tray Cable - Exposed Run)

eliminates the need for conduit when

installed in accordance with NEC

Article 336.10(7). These cables are

also UL labeled Okomarine and are

listed for marine applications.

SpecificationsInsulated Conductors: Bare soft

annealed copper, Class B stranded

per ASTM B8.

Insulation: X-Olene (XLPE), per®

UL 13, 30 mils nominal thickness,

90°C temperature rating. Meets or

exceeds requirements of UL 1277,

UL 1309 Type X90 and IEEE 1580

Type X cross-linked polyethylene

insulation.

Color Coding: Pigmented black and

white in pairs, black, red and white in

UL® c UL®

OK

ON

ITE

6 P

-OS

12

PR

16

AW

G C

U X

-OL

EN

E (

XL

PE

)

OK

ON

ITE

6 P

-OS

1 P

R 1

6A

WG

CU

X-O

LE

NE

(X

LP

E)

C

A

B

D

E

F

G

Product DataSection 5: Sheet 50

N/21060550

THE OKONITE COMPANYRamsey, New Jersey 07446

Jacket Thic

kness-mils

#16 AWG

▲267-40-3401▲267-41-3401

11

4545

0.350.37

0.100.11

7789

8597

267-40-3402267-40-3404267-40-3408267-40-3412

248

12

45608080

0.520.680.900.99

0.220.360.570.77

173244415521

178278430606

267-40-3416267-40-3420267-40-3424267-40-3436

16202436

80808080

1.181.311.401.60

1.101.351.542.01

684816937

1299

756915

10941433

268-38-4402268-38-4404268-38-4408268-38-4412

24812

60608080

0.650.781.021.21

0.330.470.811.14

240307559742

261366617809

268-38-4416268-38-4420268-38-4424

162024

808080

1.361.501.63

1.461.772.09

93111181296

108312461430

#14 AWG

Catalo

gNum

ber

Number of P

airs

Nomin

al Cable

O.D

. - In

ches

Cross-S

ectional

Area

†(s

q. in.)

Approx. N

et Weig

ht

(lbs./1

000’)

Approx. S

hipW

eight

(lbs./1

000’)

Number o

f Tria

ds

267-40-3501267-41-3501

11

4545

0.370.40

0.110.13

99103

115131

267-40-3502267-40-3504267-40-3508267-40-3512

248

12

60608080

0.590.720.971.15

0.270.410.741.03

237337570732

258366620799

16202436

808080110

1.291.421.571.57

1.311.591.932.92

914108812641189

1066124713982198

267-40-3516267-40-3520267-40-3524267-40-3536

267-38-3502267-38-3504267-38-3508267-38-3512

248

12

60608080

0.630.771.031.22

0.310.460.841.18

291430731978

3144597891103

267-38-3516267-38-3520267-38-3524

162024

808080

1.381.521.68

1.491.822.22

123814961748

139016301972

UL® c UL®

ELECTRICAL SPECIFICATIONS

Conductor Resistance, nominal-ohms/1000 f..........@20°C..........@25°C16 AWG ....................................................................4.34................4.4314 AWG ....................................................................2.68................2.73Insulation Test Voltage (spark test)....................................8000 Volts ac

Dielectric Test Voltage ........................................................1500 Volts acInsulation Resistance Constant @60°F minimum...10,000 ohms-1000 ft.Loop Resistance, nominal (2 cdr.) - ohms/1000 ft @20°C............@25°C16 AWG ..................................................................8.68...................8.8614 AWG...................................................................5.36...................5.46Mutual Capacitance (PF/ft.)*#16......................................................................................................23#14......................................................................................................25

*Typical Value

▲ Available from our CustomerAuthorized Stock Item.Service Centers.† area for calculation of cable tray fill inCross-sectionalaccordance with NEC Section 392.22.

Cut lengths of 1000 feet or longer areLength Tolerance:subject to a tolerance of ± 10%; less than 1000 feet ± 15%.

X-Olene Okoseal® ®

UL Type TC-ER/ITC -ER and cUL Type CIC-TC*or Oko-Marine Cable600 Volt Instrumentation/Signal Cable600/1000V Marine Shipboard CableSingle Pair/Triads or Multiple Pairs/Triads Type P-OSFor Cable Tray Use - Sunlight Resistant - For Direct Burial*cUL CIC-TC-ER sizes 14 AWG & larger

ApplicationsOkonite X-Ray cables are suitable for use onX-Ray apparatus for medical, industrial, re-search and control applications. They givetrouble-free performance where pulse typehigh voltages are required. Although primar-ily used with medical diagnostic imagingequipment, Okonite X-Ray cables are alsoused with equipment in industrial applica-tions as well as in research projects wherehigh voltages, low power are required.Okonite LOW NOISE X-Ray cables havespecifically been designed for use wheresensitive measurements are required. TheseLOW NOISE cables are manufactured andassurance tested to meet less than 10 pico-coulumb discharge thereby reducing noise toa minimum.Okonite LOW NOISE X-Ray cables are of-fered at 65kV, 75kV, 100kV, 230kV and250kV dc ratings.Typically, Okonite X-Ray cables are used tosupply the anode and cathode voltages tothe X-Ray tube. Since one terminal operatesat a negative potential and the other at apositive potential, the voltage across the X-Ray tube is twice (2X) the rated voltage ofthe cable.The two usual constructions are (1) threeconductor (3/C) used on typical cathode ca-ble installations, and (2) four conductor (4/C)utilized on installations with a grid controlledlead. Upon request, designs and construc-tions can be developed for specialapplications.

Product Features• Low Noise - < 10 pC @ 200 Vac/mil of in-sulation to 42 kV max.• Performance tested for long trouble-freeservice.• Small diameter.• Flexible construction.• Excellent flexing endurance.• Mechanically rugged.• Easy to strip and terminate.• Resistant to most oils and chemicals.• Complies with NEMA Standard XR-7where applicable.

InstallationThe minimum bending radius for permanentinstallation or flexing in service is four timesthe cable diameter.

SpecificationsCable Core: Each Low Noise cable corecontains two insulated filament conduc-tor. In 65, 75, and 100kV cable filamentconductors are #15 AWG (19x)[1.65mm2] tinned copper insulated withheat sealed color coded polyester tape.In 230kV cables, the filament wires are#16 AWG (19x) [1.31mm2] tinned copper.The 250 kV cable filaments are #14 AWG(19x) [2.08mm2] tinned copper. Both the230 and 250kV filament wires are insu-lated with an extrusion of ETFE. Fourconductor cables include one #20 AWG(7x) [0.52mm2] copperweld conductor perASTM B-45 insulated with heat sealedpolyester and shielded with metalized redpolyester.The tinned copper uninsulated conductorin 3/C 65, 75, 100 and 230kV cables issegmented into two #18 AWG [0.83mm2]flex stranded wires. The 4/C uninsulatedconductor is segmented into three #18AWG wires. A single #12 AWG (19x) wireis used in the 250kV cable.Core Shield: An extruded layer of semi-conducting compound encapsulates thecomposite core assembly.High Voltage Insulation: Okonite’s pre-mium EPR (ethylene-propylene rubber)insulation. This ozone resistant high volt-age dielectric is extruded in tandem withthe semiconducting layers which insuresan intimate and contaminant free inter-face between the layers.Insulation Shield: A strippable extrudedlayer of semiconducting EPR compoundis applied directly over the insulation.Shield: A braid of tinned copper wires isapplied directly over the insulation shield.Minimum coverage indicated in table.Jacket: A flexible Okoseal (speciallycompounded PVC) jacket is extrudedover the shield to provide additional me-chanical strength and resistance to mostoils and chemicals.

Okonite X-Ray/Hi-Voltage CableLow Noise65kV, 75kV, 100kV, 230kV and 250kV dc RatingThree Conductor or Four Conductor

Product DataSection 6: Sheet 1

A Coated Stranded CopperConductors

B Polyester InsulationC Extruded Semiconducting LayerD Primary Insulation – OkoguardE Extruded Insulation ShieldF Coated Copper BraidG Jacket – Okoseal

A

B

C

E

F

G

D

65kV

3 Conductors2-#15 AWG insulated1-(2-#18 AWG)uninsulated

504-22-6436 80 yes Gray 0.465 11.81 0.605 15.36 219 33 243 36

75kV

3 Conductors2-#15 AWG insulated1-(2-#18 AWG)uninsulated

504-22-3437504-22-3495

8095

no Gray 0.510 12.95 0.650 16.50247258

3738

279297

4244

4 Conductors2-#15 AWG 1-#20AWG Copperweld,insulated1-(3-#18 AWG)uninsulated

504-22-4464 80 no Gray 0.570 14.48 0.715 18.20 296 44 335 50

75kVExtraSmall

Diameter

3 Conductors2-#15 AWG insulated1-(2-#18 AWG)uninsulated

504-22-3415 80 no Gray 0.490 12.45 0.620 15.75 228 34 267 40

100kV

3 Conductors2-#15 AWG insulated1-(2-#18 AWG)uninsulated

� 504-22-3436� 504-22-4437

80noyes

Gray 0.620 15.75 0.785 19.94 341 51 380 57

4 Conductors2-#15 AWG 1-#20AWG Copperweld,insulated 1-(3#18AWG) uninsulated

504-22-4436504-22-4437

80noyes

Gray 0.660 16.75 0.845 21.46 391 58 446 66

230kV

3 Conductors2-#16 AWG insulated1-(2-#18 AWG)uninsulated

� 504-22-741080 no Black

0.980� .020

24.89� .51

1.250� .025

31.75� .64

759 113 849 126

250kV

3 Conductors2-#14 AWG insulated1-(#12 AWG)uninsulated

504-22-9430 80 no Black1.280� .020

32.51� .51

1.505� .025

38.23� .64

1119 167 1250 186

Electrical Characteristics

Rated VoltageRectified dc kV (2)

Number ofConductors

Core to ShieldCapacitance ± 10%

4/C only: Copperweld grid lead capacitance = 70 pF/ft. (230 pF/m).

pF/ft. pF/m Conductor resistance @ 25°C:

6575 (ESD)7575

100100230250

33343433

5249.5475740493531

170162154187131159115101

#16 AWG (1.31 mm2) tinned copper = 4.18 ohms/1000 ft (1.37 ohms/100 m)#15 AWG (1.65 mm2) tinned copper = 3.51 ohms/1000 ft (1.15 ohms/100 m)#18 AWG (0.83 mm2) tinned copper = 7.16 ohms/1000 ft (2.34 ohms/100 m)

2 X #18 AWG (0.83 mm2) tinned copper = 3.58 ohms/1000 ft (1.17 ohms/100 m)3 X #18 AWG (0.83 mm2) tinned copper = 2.39 ohms/1000 ft (0.78 ohms/100 m)

#20 AWG (0.52 mm2) copperweld = 24.12 ohms/1000 ft (7.91 ohms/100 m)#14 AWG (2.08 mm2) tinned copper = 2.73 ohms/1000 ft (0.895 ohms/100 m)#12 AWG (3.31 mm2) tinned copper = 1.72 ohms/1000 ft (0.564 ohms/100 m)

(2) Voltage rating is between the conductor and the shielding braid.

C/06010601

Product DataSection 6: Sheet 1

� Authorized stock Item. Available from our Customer Service Centers.

(1) Cable is helically wrapped with a cellophane tape to maintain cleanliness during installation and includes a pull cord for ease of removal.

- Designs for special applications upon request.- Refer to Product Data Section 6 Sheet 1 for X-Ray Cable - Low Noise constructions.

Catalo

gNum

ber

Net. W

t.(k

g/100m

)

Jack

etColo

r

Insu

latio

nO.D

.

mm

±0.2

5

Insu

latio

nO.D

.

Inch

es±

0.010

Jack

etO.D

.

Inch

es±

0.015

Jack

etO.D

.

mm

±0.3

8

Tinned

CopperBra

id

Covera

ge (%)

Descr

iptio

n

Net. W

t.(lb

s/100

0 ft.)

Approx.

ShipW

eight

(kg./1

00m

)

Approx.

ShipW

eight

(lbs./

1000

’)

Okonite X-Ray/Hi-Voltage CableLow Noise65kV, 75kV, 100kV, 230kV and 250kV dc RatingThree Conductor or Four Conductor

Cellophan

e Wra

p(1

)

THE OKONITE COMPANYRamsey, New Jersey 07446

ApplicationsOkonite X-Ray cables are suitable for use onX-Ray apparatus for medical, industrial, re-search and control applications. They givetrouble-free performance where pulse typehigh voltages are required. Although primar-ily used with medical diagnostic imagingequipment, Okonite X-Ray cables are alsoused with equipment in industrial applica-tions as well as in research projects wherehigh voltages, low power are required.

Typically, Okonite X-Ray cables are used tosupply the anode and cathode voltages tothe X-Ray tube. Since one terminal operatesat a negative potential and the other at apositive potential, the voltage across the X-Ray tube is twice (2X) the rated voltage ofthe cable.

The two usual constructions are (1) threeconductor (3/C) used on typical cathode ca-ble installations, and (2) four conductor (4/C)utilized on installations with a grid controlledlead. Upon request, designs and construc-tions can be developed for specialapplications.

Product Features• Performance tested for long trouble-freeservice.• Small diameter.• Flexible construction.• Excellent flexing endurance.• Mechanically rugged.• Easy to strip and terminate.• Resistant to most oils and chemicals.• Complies with NEMA Standard XR-7where applicable.

InstallationThe minimum bending radius for permanentinstallation or flexing in service is four timesthe cable diameter.

SpecificationsCable Core: Each cable contains two #15AWG (19x) [1.65mm2] tinned copper filamentwires insulated with heat sealed color codedpolyester tape. Three conductor cores in-clude two uninsulated #18 AWG [0.83mm2]flex stranded tinned copper wires. Four con-ductor cables include one #20 AWG (7x)

[0.52mm2] copperweld conductor perASTM - 45 insulated with heat sealedpolyester and shielded with metalized redpolyester. The four conductor core in-cludes three uninsulated #18 AWG flexstranded tinned copper wires.

All conductors are twisted together into acomposite assembly.

Core Shield: An extruded layer of semi-conducting compound encapsulates thecomposite core assembly.

Insulation: Okonite’s premium high volt-age EPR (ethylene propylene rubber)insulation is extruded in tandem with thesemiconducting compound ensuring anintimate contaminant free bond betweenthe layers

Shield: A semiconducting tape is appliedover the insulation with a tinned copperwire braid. Minimum coverage indicatedin table.

Jacket: A light gray flexible Okoseal(specially compounded PVC) jacket isextruded over the shield to provide addi-tional mechanical strength and resistanceto most oils and chemicals.

Okonite X-Ray/Hi-Voltage Cable65kV, 75kV and 100kV dc RatingThree Conductor or Four Conductor

Product DataSection 6: Sheet 2

A Coated Stranded CopperConductors

B Polyester InsulationC Extruded Semiconducting LayerD Insulation – OkoguardE Semiconducting TapeF Coated Copper BraidG Jacket – Okoseal

A

B

C

E

F

G

D

65kV

3 Conductors2-#15 AWG insulated1-(2-#18 AWG)uninsulated

504-22-6040504-22-6041

80yesno

Gray 0.465 11.81 0.605 15.40 219 33 252 38

75kV

3 Conductors2-#15 AWG insulated1-(2-#18 AWG)uninsulated

� 504-22-3165504-22-3164504-22-3836

808095

yesnoyes

Gray 0.510 12.95 0.650 16.50236236248

353537

273273278

414142

4 Conductors2-#15 AWG insulated1-#20 AWGCopperweld, insulated1-(3-#18 AWG)uninsulated

504-22-2164 80 no Gray 0.570 14.48 0.715 18.20 289 43 333 50

75kVExtraSmall

Diameter

3 Conductors2-#15 AWG insulated1-(2-#18 AWG)uninsulated

� 504-22-3015 80 no Gray 0.490 12.45 0.600 15.25 224 34 248 37

100kV

3 Conductors2-#15 AWG insulated1-(2-#18 AWG) uninsu-lated

504-22-1033504-22-1035

80noyes

Gray 0.620 15.75 0.785 19.90 332 49 371 55

4 Conductors2-#15 AWG insulated1-(#20 AWG) Copper-weld, insulated1-(3#18 AWG)uninsulated

504-22-2041 80 no Gray 0.660 16.75 0.845 21.50 380 57 441 66

Electrical Characteristics

Rated VoltageRectified dc kV (2)

Number ofConductors

Core to ShieldCapacitance ± 10%

4/C only: Copperweld grid lead capacitance = 70 pF/ft. (230 pF/m).

pF/ft. pF/m Conductor resistance @ 25°C:

6575 (ESD)7575

100100160250

33343433

5249.5475740493531

170162154187131159115101

#16 AWG (1.31 mm2) tinned copper = 4.18 ohms/1000 ft (1.37 ohms/100 m)#15 AWG (1.65 mm2) tinned copper = 3.51 ohms/1000 ft (1.15 ohms/100 m)#18 AWG (0.83 mm2) tinned copper = 7.16 ohms/1000 ft (2.34 ohms/100 m)

2 X #18 AWG (0.83 mm2) tinned copper = 3.58 ohms/1000 ft (1.17 ohms/100 m)3 X #18 AWG (0.83 mm2) tinned copper = 2.39 ohms/1000 ft (0.78 ohms/100 m)

#20 AWG (0.52 mm2) copperweld = 24.12 ohms/1000 ft (7.91 ohms/100 m)

(2) Voltage rating is between the conductor and the shielding braid.

B/03040602

Product DataSection 6: Sheet 2

� Authorized stock Item. Available from our Customer Service Centers.

(1) Cable is helically wrapped with a cellophane tape to maintain cleanliness during installation and includes a pull cord for ease of removal.

- Designs for special applications upon request.- Refer to Product Data Section 6 Sheet 1 for X-Ray Cable - Low Noise constructions.

Catalo

gNum

ber

Net. W

t.(k

g/100m

)

Jack

etColo

r

Insu

latio

nO.D

.

mm

±0.2

5

Insu

latio

nO.D

.

Inch

es±

0.010

Jack

etO.D

.

Inch

es±

0.015

Jack

etO.D

.

mm

±0.3

8

#34 AW

GT.C

. Bra

id

Covera

ge (%)

Descr

iptio

n

Net. W

t.(lb

s/100

0 ft.)

Approx.

ShipW

eight

(kg./1

00m

)

Approx.

ShipW

eight

(lbs./

1000

’)

Okonite X-Ray/Hi-Voltage Cable65kV, 75kV, 100kV dc RatingThree Conductor or Four Conductor

Cellophan

e Wra

p(1

)

THE OKONITE COMPANYRamsey, New Jersey 07446

Insulation/JacketOkoguard is Okonite’s registered tradename for its exclusive ethylene-propyl-ene base, thermosetting compound,whose optimum balance of electricaland physical properties is unequaled inother solid dielectrics.

This durable Okoguard insulation servesas a jacket as well. It is permanentlyembossed with a legend and has anatural, highly visible, red color.

ApplicationsOkoguard Portable Jumper cables aredesigned as flexible power leads for usewith tap-off or jumper clamps which per-mit temporary connections or “by-pass”of energized aerial lines operating atvoltages up to and including 15000V(phase to phase).

SpecificationsExtra-flexible rope

tin coated copper per ASTM B-33, flexi-ble rope stranded.

: A taped conductivescreen, whose purpose is to improveservice life, dielectric strength and elimi-nate internal corona, meets andexceeds ICEA Standard S-96-639.

Okoguard meets and ex-ceeds ICEA Standard S-93-639.

Product FeaturesExtra-flexible conductors for ease

of handling under adverse condi-tions.

Conductor screen for improvedvoltage stress control.

• Heat, moisture and ozone resistant90°C Okoguard Insulation/Jacket.

• Okoguard is red for visual attentionand it has good color stability evenwhen exposed to strong sunlight.

• Excellent low temperatureproperties.

Okoguard® Aerial Jumper Cable

Coated, Stranded CopperConductorStrand ScreenInsulation/Jacket-Okoguard

Okoguard Aerial Jumper Cable

� 303-21-1934� 303-21-1938� 303-21-1940� 303-21-1944

21/02/04/0

259259259437

0.3190.4080.4500.592

0.7800.8630.9101.052

19.822.023.327.2

425583687997

480638752

1092

192258298400

� Available from our Customer Service Centers

is 150 ft.—1000' N.R. Reel. Standard package will be

furnished where orders do not specify otherwise.

C/12040604THE OKONITE COMPANY

Ramsey, New Jersey 07446

Ampacity based on 90°C conductor temperature, 40°C ambient temperature.For ampacity correction factors covering various ambient temperatures:

AmbientTemperature

DegreesCorrection

Factor

C F

1020304050

506886

104122

1.261.181.101.000.90

Okoguard is Okonite’s registered trade namefor its exclusive medium voltage grade ethyl-ene-propylene rubber (EPR) based,thermosetting compound, whose optimumbalance of electrical and physical propertiesis unequaled in other solid dielectrics.Okoguard insulation, with the distinctive redcolor and a totally integrated EPR system,provides the optimum balance for long, prob-lem free service.

The Okolon TS-CPE jacket on this cable is avulcanized chlorinated polyethylene basedcompound which is mechanically rugged,flame, and oil resistant.

Okoguard-Okolon TS-CPE cables are heavyduty nonshielded cables designed for use atup to 5kV in wet or dry airport lighting appli-cations.Okoguard-Okolon TS-CPE nonshielded air-port lighting cables are recommended foruse in series lighting circuits for runways andcontrol systems. Cables can be installed inmetallic or non-metallic conduit, directly bur-ied or aerial application.

Meets or exceeds the requirements of FAAAdvisory Circular AC 150/5345-7F.

Annealed uncoated coppercompact Class B stranded per ASTM B-496.

Extruded semiconduct-ing EPR strand screen. Meets or exceedselectrical and physical requirements ofICEA S-96-659/NEMA WC71.

Meets or exceeds electricaland physical requirements of ICEAS-96-659/NEMA WC71. Insulation thick-ness per Table 4-3 for wet or dryapplications.

Meets or exceeds electrical andphysical requirements of ICEAS-96-659/NEMA WC71 for chlorinatedpolyethylene jackets.

• Resistant to runway and wing de-icers• 90°C Continuous Rating,130°C Emergency Overload Rating,250°C Short Circuit Rating• Exceptional resistance to surfacetracking• Superior Flexibility• Constructed for “wet” locationapplications• Excellent corona resistance• Stress cones not required• Resistant to most oils, acids, andalkalies

*Applications governed by the NationalElectrical Code limit non-shielded cableto 2.4kV

Okoguard®-Okolon® TS-CPE5kV Airport Lighting Cable*

One Okopact (Compact Stranded) Copper Conductor/90°C Rating Wet or Dry

Uncoated, Okopact (CompactStranded) Copper ConductorStrand Screen-ExtrudedSemiconducting EPRInsulation-Okoguard EPRJacket-Okolon TS-CPE

� 114-24-2213� 114-24-2217

8 8.46 13.3

125 3.18125 3.18

80 2.0380 2.03

0.60 15.10.63 16.0

215260

250295

� Available from our Customer Service Centers.

are available.

E/14080606 THE OKONITE COMPANYRamsey, New Jersey 07446

A

B

C

D

InsulationOkonite EPR insulation is a heat, mois-ture and chemical resistant,mechanically rugged compound. The in-sulation thickness for size #14 AWGthrough #9 AWG is 5/64" and for #6AWG through #2 AWG is 6/64". Oneconductor in each layer is identified as"Tracer". In addition, each conductor isnumber coded for ease of identification.

Assembly and FinishIndividual conductors are assembledwith suitable fillers, where necessary,and a cable cushioning tape. A 7 mil flatcopper alloy tape is then helically ap-plied, giving outstanding mechanicalprotection. The black Okolene® (poly-ethylene) jacket is then applied overall.

ApplicationsOkonite Armored Underground SignalCables are designed for use in all vitalrailroad signal circuits where security ofservice and long life are required in allvital circuit and safety related applica-tions. These cables are recommendedfor use where crush resistance, termiteand rodent protection are considera-tions and in all wet and dry locations.

SpecificationsAREMA Signal Manual Part 10.3.17Conductors: Solid uncoated copperper ASTM B-3, stranded uncoated com-pact round copper per ASTM B-496.

Insulation: Meets or exceeds electri-cal and physical requirements ofICEA S-95-658 (NEMA WC70) andAREMA Manual Part 10.3.19, thick-ness per table 10317-4.Armor Tape: Copper alloy C19400per ASTM B-465.Jacket: Meets or exceeds electricaland physical requirements of ICEAS-95-658, Part 4.1.5.

Product Features• Mechanically rugged.• Resistant to aging.• Easy to install and splice.• Resistant to environmental haz-ards.• Superior moisture resistance.• Outstanding termite and rodent pro-tection.• Excellent electrical properties...high dielectric strength, low SIC andpower factor and high insulation re-sistance.• The Pull Cord feature affords easyand quick accessibility to conductorsfor splicing and terminating.• Sequential footage markings onsurface of outer jacket.

Okonite® ArmoredUnderground Signal CablesWith P.C.F. (Pull Cord Feature)Heavy Duty Direct Burial Railroad Signal Cable— AREMA Type 1 EPR Insulation — 600VMultiple Copper Conductors/90°C Rating

Product DataSection 7: Sheet 1

COMPOSITE CONSTRUCTIONS

Okonite Insulation: #14 AWG through #9 AWG 5/64”, #6 AWG 6/64”

CatalogNumber

CompositeMake-Up

ConductorsNo. x Size No. x Size(# Strands) (# Strands)

OuterJacket

Thickness64th

ApproxCable

O.D. (In.)

ApproxNet Wt.Lbs./M’

ApproxShipWt.

Lbs./M

206-11-8974� 206-11-8255� 206-11-6283

7/C15/C19/C

2 x 9 (1X)3 x 6 (1X)6 x 6 (1X)

5 x 14 (1X)12 x 14 (1X)13 x 14 (1X)

566

0.991.481.69

52311451674

57412731877

� Authorized Stock Item - Available from Customer Service Centers.

Composite Cable Constructions are also available with stranded conductors.Consult your Okonite Representative.

B

A

C

E

D

F

TH

EO

KO

NIT

EC

O.5

/C14

AW

GC

U

A Solid or Stranded Uncoated CopperConductors

B Insulation—Okonite #14 AWG-#9AWG 5/64", #6 - #2 AWG 6/64" withprinted number code and tracer

C Cushion Tape LayerD Flat Copper Alloy Armor TapeE Pull CordF Jacket—Okolene with sequential

footage marking

Okonite ArmoredUnderground Signal CablesOkonite Insulation: #14 AWG Through #9 AWG, 5/64", #6 through #2 AWG, 6/64"

CatalogNumber

Size AWGNo. of

Strands (1)No.

Condrs.Outer Jacket

Thickness-64thApprox. Cable

O.D. InchesNet Wt.Lbs./M'

Approx. ShipWt. Lbs./M'

� 206-11-6882206-11-6883206-11-6884

141414

Sol.Sol.Sol.

234

444

.63

.67

.73

184220267

241286338

� 206-11-6885� 206-11-6887

206-11-6889

141414

Sol.Sol.Sol.

579

455

.79

.891.03

314409526

408510671

206-11-6890� 206-11-6892

206-11-6895

141414

Sol.Sol.Sol.

101215

556

1.101.161.31

583649804

790792994

206-11-6896� 206-11-6899

206-11-6901

141414

Sol.Sol.Sol.

161921

666

1.311.381.45

928959

1050

102911511250

� 206-11-6907� 206-11-6910

206-11-6692

141412

Sol.Sol.Sol.

2737

2

674

1.651.87

.66

13081735

206

16382076

273

206-11-6693206-11-6694206-11-6695

121212

Sol.Sol.Sol.

345

444

.70

.76

.83

256313368

330392471

206-11-6697206-11-6699206-11-6700

121212

Sol.Sol.Sol.

79

10

555

.941.091.16

487625699

594781866

206-11-6702206-11-6812206-11-6813

121010

Sol.Sol.Sol.

1223

544

1.26.70.75

804244311

952317384

206-11-6814206-11-6815206-11-6817

101010

Sol.Sol.Sol.

457

455

.82

.921.00

383479611

483577746

206-11-6819206-11-6820206-11-6822

101010

Sol.Sol.Sol.

91012

566

1.171.251.35

772872

1007

93410781199

206-11-6922� 206-11-6923

206-11-6924

999

Sol.Sol.Sol.

234

445

.73

.77

.88

283351452

350443554

� 206-11-6925� 206-11-6927

206-11-6928206-11-6929

9999

Sol.Sol.Sol.Sol.

5789

5555

.961.041.131.23

549686775901

640829935

1057

� 206-11-6930206-11-6931

� 206-11-6242

996

Sol.Sol.Sol.

1012

2

665

1.331.400.93

10521161

457

12211338

564

� 206-11-6243206-11-6244

� 206-11-6245

666

Sol.Sol.Sol.

345

555

0.971.081.18

591730913

724881

1044

� 206-11-6247206-11-6248

� 206-11-6249

666

Sol.Sol.Sol.

789

666

1.321.431.54

119313511532

136815521820

� 206-11-6070*� 206-11-6374� 206-11-6042� 206-11-6373� 206-11-6045� 206-11-6130**

664442

777777

3*4*2353**

565566

1.041.131.031.101.181.25

671829606801911

1191

753896674894

13561346

Minimum Manufacturing Quantity is 1000 ft. Standard Package—1000' N.R. Reel.

� Authorized Stock Item - Available from Customer Service Centers.

(1) This construction is also available with stranded conductors. Consult yourOkonite Representative.* Includes 1 #8 AWG Class B Ground** Includes 1 #6 AWG Class B Ground

J/20020701

THE OKONITE COMPANYRamsey, New Jersey 07446

Product DataSection 7: Sheet 1

Okonite EPR is Okonite's tradename for its heat resistant, mechani-cally rugged ethylene-propylenebased insulating compound. The in-sulation thickness for wire sizes #9AWG is 5/64" and for #6 AWG is6/64".

The Okolene (PE) jacket suppliedwith this cable provides excellent re-sistance to mechanical abuse,weathering and most acids, oils andalkalies. Color Coded; 1-Black,1-Red.

Okonite-Okolene 600V Duplex TrackWire is recommended for use intrack circuits, signal operations, carretarder and switch machine appli-cations. Can be installed in eitherwet or dry locations, in conduit traysor trough or buried direct.

Solid uncoated cop-per per ASTM B-3.

Per ICEA S-95-658,and AREMA Signal Manual Part10.3.19.

Meets or exceeds thephysical and electrical require-ments of ICEA S-95-658, andAREMA Signal Manual Part10.3.21

• Exceptional heat resistance.• 90°C Continuous Rating130°C Emergency Overload Rat-ing.250°C Short Circuit Rating.• Mechanically rugged.• Flexible, easy to handle andsplice.• Resistant to most oils, acids, al-kalies and effects of weather.• Stable electrical and physicalproperties.• Excellent moisture resistance.

Okonite®-Okolene® Duplex Track Wire

One Copper Conductor/90°C Rating

Solid Uncoated Copper ConductorsInsulation - Okonite-Sizes #9 AWGand #8 AWG-5/64", #6 AWG-6/64"Jacket-Okolene, Color Coded;1-Black, 1-Red

150-12-3931� 150-12-3933

96

SolidSolid

44

0.83"1.00"

199329

243404

� Authorized Stock Item: Available from our Customer Service Center-1000' Non-Returnable Reel

THE OKONITE COMPANYRamsey, New Jersey 07446E/11100706

B

A

InsulationOkonite EPR is Okonite's trade name for itsheat resistant, mechanically ruggedethylene-propylene based insulating com-pound. The insulation thickness for wiresizes are listed below.

Jackets and FinishesThe Blue Okoseal® (PVC) jacket suppliedwith this cable provides excellent resistanceto mechanical abuse, flame, weathering, andmost acids, oils, and alkalies.

ApplicationsOkonite Tower and Case Wire is recom-mended for use as relay and associatedsignal apparatus wiring and for connectorwire use where a flexible, small diameterwire is required.

SpecificationsConductor: Uncoated stranded copperstranded per ASTM B-8.Insulation: Per ICEA S-95-658. Meets orexceeds all requirements for EPR insulation.Jacket: Per ICEA S-95-658. Meets or ex-ceeds all requirements.Okonite Tower and Case Wire meets or ex-ceeds the requirements of AREMA ManualPart 10.3.15.

Product Features• Exceptional heat resistance.• 90°C Continuous Rating130°C Emergency Overload Rating.250°C Short Circuit Rating.• Mechanically rugged.• Flexible, easy to handle and splice.• Flame resistant—meets U.L. horizontalflame test.• Resistant to most oils acids, alkaliesand effects of weather.• Stable electrical and physical proper-ties.

Okonite® TC BlueTower and Case Wire600 VoltOne Copper Conductor/90°C Rating

Product DataSection 7: Sheet 10

A Uncoated, Stranded CopperConductor

B Insulation—OkoniteC Jacket—Blue Okoseal

CatalogNumber

SizeAWG

No. ofStrands

InsulationThickness

Mils

JacketThickness

Mils

Approx.O.D.(In.)

Approx.Net Wt.Lbs./m'

Approx.Ship Wt.Lbs./m'

� 152-11-3002� 152-11-3024

152-11-3026

161412

191919

303045

202020

.17

.20

.23

202642

242846

� 152-11-3038152-11-3108152-11-3010

� 152-11-3015

1010

96

19371919

30454560

20202530

.23

.26

.29

.37

565871130

606275143

� Authorized Stock Item - Available from our Customer Service Centers.Note: The construction described has a Blue Jacket. Consult your local Okonite Representa-tive for details about alternate colors.Standard Package - #16 AWG and #14 AWG, 1,000 spool; #12 AWG, #10 AWG,and #9 AWG, 500' spool.

F/21010710

TH

EO

KO

NIT

EC

O.1

/C9

AW

GC

UT

OW

ER

AN

DC

AS

EW

IRE

B

A

C

THE OKONITE COMPANYRamsey, New Jersey 07446

Okonite EPR is Okonite’s trade namefor its heat resistant, mechanically rug-ged ethylene-propylene based insulatingcompound. The insulation thickness forwire size #16 AWG and #14 AWG is2/64" and for #12 AWG and #10 AWG itis 3/64".

The Okolon (TS-CP) jacket suppliedwith this cable provides excellent resis-tance to mechanical abuse, flame,weathering and most acids, oils and al-kalies.

Okonite Okolon (TS-CP) 600V CaseWire is recommended for use as relayand associated signal apparatus wiringand for connector wire use where a flex-ible, small diameter wire is required.

Uncoated stranded copperper ASTM B-8.

Per ICEA S-95-658.Per ICEA S-95-658, Part 4.1.13

and 4.1.3.

• Exceptional heat resistance.• 90°C Continuous Rating130°C Emergency Overload Rating.250°C Short Circuit Rating.• Mechanically rugged.• Flexible, easy to handle and splice.• Flame resistant — meets U.L. hori-zontal flame test.• Resistant to most oils, acids, al-kalies and effects of weather.• Stable electrical and physical prop-erties.

Okonite® Okolon® - (TS-CPE) Case Wire

One Copper Conductor/90°C Rating

Uncoated, Stranded CopperConductorInsulation—Okonite—#16 AWG and#14 AWG - 2/64"; #12 AWG thru #6AWG - 3/64"Jacket - Okolon TS-CPE

151-12-1051�151-12-1081

151-12-1101

161412

191919

111

.16

.18

.23

202642

243046

151-12-1140151-12-1171

�151-12-1201

1096

191919

111

.25

.26

.31

5867

112

6275

122� Authorized Stock Item - Available from Customer Service Centers.

— #16 AWG and #14 AWG, 1000’ spool; #12 AWG thru #6 AWG, 500’ spool.

THE OKONITE COMPANYRamsey, New Jersey 07446

G/11100711

B

A

TH

EO

KO

NIT

EC

O.O

KO

LON

TS

-CP

EC

AS

EW

IRE

InsulationOkonite EPR is Okonite's tradename for its heat resistant, mechani-cally rugged ethylene-propylenebased insulating compound. The in-sulation thickness for wire sizes #16AWG and #14 AWG is 2/64" and for#12 AWG through #9 AWG it is3/64".

FinishThe nylon braid and lacquer finishsupplied with this cable provides ex-cellent resistance to mechanicalabuse, weathering and most oils, ac-ids and alkalies.

ApplicationsOkonite-Nylon Braid 600V CaseWire is recommended for use as re-lay and associated signal apparatuswiring, and for connector wire usewhere a flexible, small diameter wireis required.

SpecificationsConductor: Uncoated, strandedcopper conductor per ASTM B-8.Insulation: Per ICEA S-95-658.Finish: Black nylon braid (100%coverage) with clean lacquer fin-ish.

Product Features• Mechanically rugged.• 90°C Continuous Rating130°C Emergency Overload Rat-ing.250°C Short Circuit Rating.• Mechanically rugged.• Flexible, easy to handle andsplice.• Resists most oils, acids, alkaliesand effects of weather.• Stable electrical and physicalproperties.

Okonite®-Nylon Braid Case Wire600VOne Copper Conductor/90°C Rating

Product DataSection 7: Sheet 12

A Uncoated, Stranded CopperConductor

B Insulation—Okonite #16 and #14AWG 2/64"; #12 AWG through #9AWG 3/64"

C Finish—Nylon Braid with LacquerOverall

Nominal Finish Thickness: 5 mils

CatalogNumber Size AWG No. of

Strands

InsulationThickness

64 th's

Approx.O.D. (In.)

Approx.Net Wt.Lbs./M'

Approx.Ship Wt.Lbs./M'

�151-12-9051151-12-9081

�151-12-9111

161412

191919

223

.14

.15

.20

162238

202642

151-12-9145�151-12-9161

151-12-9181

10109

193719

333

.22

.23

.24

505162

545566

� Authorized Stock Item — Available from our Customer Service CentersStandard Package — #16 AWG and #14 AWG, 1000' spool;#12 AWG, #10 AWG, and #9 AWG, 500' spool.

F/20020712

B

A

C

THE OKONITE COMPANYRamsey, New Jersey 07446

InsulationOkonite EPR® is Okonite’s trade namefor its heat resistant, mechanically rug-ged ethylene-propylene based insulatingcompound. The insulation thickness forDEL numbers 002 and 004 is 2/64”, for008 through 016 is 3/64”, 018 through026 is 4/64”, 030 through 040 is 5/64”,044 and 048 is 6/64”, 050 through 056 is7/64” and for 058 it is 8/64”.

Jackets and FinishesThe Okolon® TS-CPE jacket suppliedwith this cable provides excellent resis-tance to mechanical abuse, flame,weathering, most oils, acids and alka-lies.

ApplicationsOkonite Type DEL, Diesel-Electric Loco-motive Traction and Car Wires isdesigned for use in locomotives and carequipment circuits where reliability is forprime consideration. DEL can also beused in other low voltage applicationswhere flexibility is important. It is suit-able for use in wet or dry locations, inconduits, ducts, cable troughs or trays.

SpecificationsConductor: Coated copper strandedper AREMA Recommended Practice,Section M, RP-588, as applicable andICEA S-95-658.Insulation: Per AREMA RecommendedPractice, Section M, RP-588, as applica-ble and ICEA S-95-658.Jacket: Per AREMA Recommended Prac-tice, Section M, RP-588, as applicable andICEA S-95-658.

Product Features• Extreme heat resistance.• Extra flexible conductor.• 90°C Continuous Rating,110°C Hot Spot Rating,130°C emergency Overload Rating,300°C Short Circuit Rating.• Mechanically rugged.• Exceptional resistance to deforma-tion and cut through at hightemperature.• Excellent flame resistance. Meetsboth UL vertical and horizontal flametest requirements.• Resistant to oils, weather and mostchemicals and alkalies.• Stable electrical properties at hightemperatures.• Meets the RHH/RHW requirementsof NEC/UL and can be labeled assuch on special orders.

Type DEL600-2000V Diesel-Electric Locomotive,Motor Traction and Car WireOne Copper Conductor/90°C — 110°C Hot Spot Rating

Product DataSection 7: Sheet 17

A Coated Stranded Copper ConductorB Separator (sizes 36,700 CM and

larger)C Insulation - OkoniteD Jacket - Okolon TS-CPE

B

A

C

D

TH

EO

KO

NIT

EC

O.D

EL

016

8A

WG

Type DEL600-2000V Diesel - Electric Locomotive,Motor Traction and Car WireOne Copper Conductor/90°C - 110°C Hot Spot Rating

CatalogNumber

DELNumber

SizeAWG

or MCM

No. ofStrands

Thickness64ths

Ins. Jkt.

VoltageRating

Approx.O.D. In.

Approx.Wt. Lbs./M’Net Ship

Ampacity AC or DC1/C 3-1/C

in Air1 in Duct²

ConduitSize

Inches3

DC Resis@ 25°C

ohms/1000’

� 112-11-1702112-11-1704112-11-1708

002004008

161414

19 X .011719 X .014219 X .0147

223

111

600600

2000

.16

.17

.21

192531

232835

243333

182424

1/2”1/2”1/2”

4.4902.7902.790

112-11-1710� 112-11-1714

112-11-1716

010014016

1210

8

19 X .017927 X .020137 X .0201

333

111

200020002000

.23

.26

.28

436179

446078

395774

294151

1/2”3/4”3/4”

1.7201.1000.690

112-11-1718112-11-1720112-11-1722

018020022

654

61 X .020191 X .0201

105 X .0201

444

222

200020002000

.41

.44

.46

144182204

141200222

101129142

728995

1”1 1/4”1 1/4”

0.4400.3500.280

112-11-1724112-11-1726112-11-1730

024026030

321

125 X .0201150 X .0201225 X .0201

445

223

200020002000

.49

.55

.69

242285445

241298497

160180233

111124153

1 1/4”1 1/2”2”

0.2200.1800.140

112-11-1732112-11-1734112-11-1738

032034038

1/02/03/0

275 X .0201325 X .0201450 X .0201

555

333

200020002000

.72

.76

.86

492594786

550633842

268297367

175193236

2”2”2 1/2”

0.1100.0900.070

112-11-1740112-11-1744112-11-1748

040044048

4/0313.1444.4

550 X .0201775 X .0201

1100 X .0201

566

333

200020002000

.891.061.20

92612891707

98513711830

419518653

268328402

2 1/2”3”3 1/2”

0.0600.0400.030

112-11-1750112-11-1752112-11-1754

050052054

535.3646.4777.7

1325 X .02011600 X .02011925 X .0201

777

444

200020002000

1.351.441.53

214125452842

226327003148

728813904

446496546

4”4”5”

0.0200.0180.016

112-11-1756112-11-1758

056058

929.21111.1

2300 X .02012750 X .0201

78

44

20002000

1.621.79

35164208

35604072

10021119

594637

5”5”

0.0130.011

� Authorized Stock Item - Available from CustomerService Centers.

Standard Package - 1000’ Non-Returnable Reel; #16 #8- 1000’ coil in carton; # 6 - 500’ coil in carton; #5 - #4/0 -2000’ N.R. Reel; #313.1 MCM and Larger - 1000’ N.R.Reel1 Ampacities based on single insulated conductor in freeair, 90°C conductor temperature, 30°C ambient air tem-perature per NEC Table 310.17.

2 Ampacities based on three (3) insulated conductors in asingle enclosed or exposed conduit with 90°C conductortemperature and 30°C ambient air temperature per NECTable 310.16. For other ambient temperatures refer toNEC Table 310.15(B)(1).3 Based on three (3) conductors in conduit with a fill of40% or less.

G/21080717

Product DataSection 7: Sheet 17

THE OKONITE COMPANYRamsey, New Jersey 07446

Applications

The C-L-X Terminating Tool Kit contains allthe tools required to remove the overalljacket and aluminum sheath from C-L-Xpower, control, and instrumentation ca-bles. The Cable Slitting Saw may also beused on interlocked armor and leadsheathed cables. The Cable Slitting Sawprovides a simple and efficient means ofremoving the aluminum C-L-X sheath. It isavailable in either an electric or a pneu-matic model. Both models have aretractable blade guard to protect the user.The electric model is powered by a 2500rpm, 120 Volt ac double insulated motor.The lightweight pneumatic model is pow-ered by a 2200 rpm motor which requires90 psi of air pressure for maximum effi-ciency. The Small Cable Guide keeps thesaw centered on the cable when slitting ca-bles of 1” diameter or less.The High Speed Steel Saw Blades providea smooth cut in the aluminum sheath andhave a cutting depth of 3/8” without the ca-ble guide.

Removing the C-L-X Armor

This procedure applies to all types of C-L-Xarmor - aluminum, copper, bronze andstainless steel. Safe working practices areto be observed, e.g., safety glasses andwork gloves. Practice sessions are recom-mended to familiarize all concerned withthe procedures and equipment.

1. Remove the jacket to expose the desiredlength of un-armored cable within the en-closure.

2. Refer to the C-L-X fitting instructions forthe length of C-L-X armor to be exposedbeyond the end of the jacket and markthe C-L-X armor at the top of the crownnearest to that point.

• For C-L-X Diameters 1 5/8” andSmaller, Go To Steps 10 through 12.

• For C-L-X Diameters greater than 15/8” Follow Steps 3. Through 9.

C-L-X Terminating Tool Kit

Product DataSection 6: Sheet 5

C-L-X TERMINATING TOOL KIT CONTENTS1 Cable Slitting Saw1 Small Cable Guide

12 2” dia. High Speed Steel Saw Blades1 Tubing Cutter1 Channel Lock Pliers1 10' Retractable Tape

1 5/16” x 11” Screwdriver1 Cable Knife, 4” blade1 Hacksaw Blade Holder3 10” Hacksaw Blades1 Tool Case1 Padlock with 2 keys

PACKAGING

Catalog Number Description Net Weight(lbs.)

Shipping Weight(lbs.)

C-L-X Terminating Tool Kit

� 606-01-1026� 606-01-1526

Electric - 120 Volt acPneumatic - 90psi

2020

2121

Cable Slitting Saw, Small Cable Guideand 12 High Speed steel saw Blades

� 606-01-0026� 606-01-0526

Electric - 120 Volt acPneumatic - 90psi

1919

2020

12 High Speed Steel Saw Blades

� 606-01-5754 2” diameter, 7 teethper inch, packaged ina round tin container

1 1

� Authorized Stock Item

C-L-X Terminating Tool Kit

3. First the C-L-X armor will be circumferentially cut using a hack-saw blade, (note the C-L-X saw tool kit is supplied with ahacksaw blade and blade holder) cut through the crown (highpoint) of the C-L-X at an angle so as to connect (or bridge) thevalleys (low points) on both sides of the crown.

4. Again using a hacksaw blade, make a circumferential score inthe valleys adjacent to the cut crown connecting both sides ofthe crown cut to the valleys. Do not cut through armor in valleys.

5. Holding the score area rigid, flex the cable by moving the freeend so as to break the score around the circumference of thecable.

6. Next the C-L-X will be longitudinally cut by performing thefollowing:Note on the C-L-X Saw - The longitudinal cut is made with theC-L-X saw, which has an adjustable positive depth stop that canbe set so the saw blade cuts through the crowns and partiallycuts through the valleys. A proper saw depth is achieved when80 to 95 % of the metal in the valley is removed. Use an extrapiece of the cable being terminated to adjust the blade depth and

practice.

Set blade to remove 80 to 95% of the metal thick-ness in the valley.

7. With cable secured, start at the free end of the cable andadvance the Kett saw, making sure to use slight downwardpressure to maintain the depth of cut along the cable, to the ringcut. When advancing the saw, be sure maintain a straight line bycutting along the high point of the cable; this affects the cut depthalso. See following:

Proper Saw Position

If it is necessary to stop cutting or if a portion of the cut is to be re-peated, use caution when reinserting the blade as kickback mayoccur.

8. At the completion of the longitudinal cut, starting at the free end,insert a wide blade screwdriver into the cut and twist. Repeat un-til the ring cut is reached. This will cause the remaining metal inthe valleys to break open and the armor to loosen on the cable.Do not drive the screwdriver into the cut with excessive force asthis may damage the underlying conductors.

9. Slide the armor off the cable. In the event that the armor is tightaround the cable, pliers may be used to grab the armor at thesplit and pull it away from the cable. For large diameter cables,where long lengths of armor are to be removed, two cuts spaced180° apart are recommended so that the armor may be removedin two pieces.

• For C-L-X Diameters 1 5/8” and Smaller Follow Steps 10.

Through 13.

10. Using a hacksaw blade or tubing cutter, circumferentially scorethe C-L-X armor. Grip the cable in both hands with the scorecentered between hands, and flex the cable at the score line untilit opens. Slide the sheath off the cable.

11. For C-L-X cables with an inner jacket or cable constructionswhere the C-L-X armor is tight fitting around the insulatedconductors, the C-L-X saw should be used with the optional redcolored cable guide. This guide assists in centering the saw onsmall diameter cable. The procedures and precautions of steps3 to 9 apply here also.

12. Remove the cable fillers and marker tape and install the C-L-Xfitting as per the manufacturer’s instructions. The cable is nowready to be terminated into the enclosure.

Product DataSection 6: Sheet 5

THE OKONITE COMPANYRamsey, New Jersey 07446G/17040605

Correct Incorrect

CONDUCTOR

COLOR CODING SEQUENCE

ICEA S-73-532 TABLE E-2

Color Sequence (No Green or White Conductors)

Conductor

Number

Base

Color

Tracer

Color

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

Black

Red

Blue

Orange

Yellow

Brown

Red

Blue

Orange

Yellow

Brown

Black

Blue

Orange

Yellow

Brown

Black

Red

Orange

Yellow

Brown

Black

Red

Blue

Yellow

Brown

Black

Red

Blue

Orange

Brown

Black

Red

Blue

Orange

Yellow

Black

Black

Black

Black

Black

Black

Red

Red

Red

Red

Red

Blue

Blue

Blue

Blue

Blue

Orange

Orange

Orange

Orange

Orange

Yellow

Yellow

Yellow

Yellow

Yellow

Brown

Brown

Brown

Brown

Brown

Special Order: Any or all of the following conductors may be added whenspecifically requested by the customer to meet his specific applicationrequirements. These conductor codings comply with UL and NEC requirements

Purpose Base Color Tracer Color

Equipment Grounding UninsulatedGreenGreen 1 or more continuous yellow stripes

Grounded WhiteWhiteWhiteWhiteWhiteWhiteWhite

Black continuous stripeRed continuous stripeBlue continuous stripeOrange continuous stripeBrown continuous stripeNumeric Printing

MISCELLANEOUS

INFORMATION

NOTES

NOTES

Oko

nite

3/2

021

Houston, TX

Servic

e C

enters

Ramsey, NJ

Kansas City, KS

Pittsburgh, PAPortland, ORNew Orleans, LA

Corporate H

DQ

Cumberland, RI - Manufacturing Plant

Orangeburg, SC - Compound Facility Orangeburg, SC - Manufacturing Plant

Richmond, KY - Manufacturing Plant Santa Maria, CA - Manufacturing Plant

Facilities OverviewM

anufa

cturin

g P

lants

Okonite CablesDistrict Offices, Manufacturing Plants & Service Centers

Paterson, NJ - Manufacturing Plant

New Orleans District Officeand Service Center(504) 467-1920

FAX: (504) 467-1926

E-Mail: [email protected]

New York District Office

NJ (973) 742-8040

NY (212) 239-0660

FAX: (973) 742-2156

E-Mail: [email protected]

Philadelphia District Office

(302) 318-2054

FAX: (302) 368-4163

E-Mail: [email protected]

Phoenix District Office

(480) 838-8596

FAX: (480) 897-8924

E-Mail: [email protected]

Pittsburgh Service Center

(724) 899-4300

FAX: (724) 899-4320

E-Mail: [email protected]

Portland District Office

& Service Center

(503) 598-0598

FAX: (503) 620-7447

E-Mail: [email protected]

Salt Lake District Office(801) 262-1993

FAX: (801) 262-3167

E-Mail: [email protected]

San Francisco District Office(925) 830-0801

FAX: (925) 830-0954

E-Mail: [email protected]

St Louis District Office(314) 770-9070

FAX: (314) 770-9140

E-Mail: [email protected]

Tampa District Office(813) 627-9400

FAX: (813) 246-4705

E-Mail: [email protected]

Washington District Office(302) 318-2054

FAX: (302) 368-4163

E-Mail: [email protected]

International Sales(281) 821-5500

FAX: (281) 821-7855

E-Mail: [email protected]

Atlanta District Office(770) 928-9778

FAX: (770) 928-0913

E-Mail: [email protected]

Birmingham District Office(205) 655-0390

FAX: (205) 655-0393

E-Mail: [email protected]

Boston District Office(603) 625-1900

(781) 749-3374

FAX: (603) 624-2252

E-Mail: [email protected]

Charlotte District Office(704) 542-1572

FAX: (704) 541-6183

E-Mail: [email protected]

Chicago District Office(630) 961-3100

FAX: (630) 961-3273

E-Mail: [email protected]

Houston District Office& Service Center(281) 821-5500

FAX: (281) 821-7855

E-Mail: [email protected]

Kansas City District Office& Service Center(913) 422-6958

FAX: (913) 422-1647

E-Mail: [email protected]

Los Angeles District Office(562) 590-3070

Fax: (562) 590-3139

E-Mail: [email protected]

Cleveland District Office(330) 926-9181

FAX: (330) 926-9183

E-Mail: [email protected]

Dallas District Office(940) 383-1967

FAX: (469) 630-0048

E-Mail: [email protected]

Denver District Office(303) 772-3517

FAX: (303) 772-3513

E-Mail: [email protected]

Minneapolis District Office(763) 432-3818

FAX: (763) 432-3811

E-Mail: [email protected]

Baton Rouge District Office(504) 467-1920

FAX: (504) 305-4773

E-Mail: [email protected]

05673102 Hilltop Road, Ramsey, NJ 07446 201.825.0300 Fax: 201.825.9026 www.okonite.com• •Printed on post consumer paper