Post on 01-May-2023
te
te
C-101
SIT
E P
LA
N
NORTH
SURVEY FROM PERVIOUS U.S. CELLULAR JOBS4.
SITE PHOTOS PROVIDED BY EDGE CONSULTING ENGINEERS, INC.3.
NORTH ARROW SHOWN AS APPROXIMATE.2.
AERIAL IMAGE FROM GOOGLE EARTH CAPTURED ON 10/03/2018.1.
NOTES:
SO
UT
H C
LE
AR
LA
KE
AV
E.
VIN
CE
NT
ST
.
ANSLEY AVE.
SEE T-201 FOR DETAILS
EXISTING WATER TOWER;
U.S. CELLULAR UTILITY EASEMENT
C/L OF EXISTING 8' WIDE
RAILROAD
EQUIPMENT SHELTER
EXISTING U.S. CELLULAR
PROPERTY LINE
PR
OP
ER
TY LIN
E
PROPERTY LINE
PROPERTY LINE
LIBERTY PARK
ACCESS EASEMENT
U.S. CELLULAR
C/L OF EXISTING 12' WIDE
30' 0 60'
22" x 34" - 1" = 30'
11" x 17" - 1" = 60'SCALE:
30'
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
C-1
01.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
C-102C
EN
LA
RG
ED
SIT
E P
LA
N
NORTH
B
A
COMPOUND OVERVIEW
05' 5'
22" x 34" - 1" = 5'
11" x 17" - 1" = 10'SCALE:
10'
ON FIELD MEASUREMENTS AND SITE PHOTOS.
SURVEY FROM PREVIOUS U.S. CELLULAR JOB. SITE LAYOUT BASED3.
SITE PHOTOS PROVIDED BY EDGE CONSULTING ENGINEERS, INC.2.
NORTH ARROW SHOWN AS APPROXIMATE.1.
NOTES:
AERIAL OVERVIEW
B
U.S. CELLULAR EQUIPMENT SHELTER
CSEE A-501 FOR DETAILS
MOUNT TO SHELTER EXTERIOR;
PROPOSED LTE GPS ANTENNA
SEE A-101 FOR DETAILS
EQUIPMENT SHELTER;
EXISTING U.S. CELLULAR
EXISTING ICE BRIDGE (TYP.)
SEE T-502 FOR DETAILS
ALONG ICE BRIDGE IN VACANT SNAP-INS;
PROPOSED HYBRID CABLES ROUTE
TO REMAIN
EXISTING CDMA GPS ANTENNA
ACCESS EASEMENT
U.S. CELLULAR
C/L OF EXISTING 12' WIDE
U.S. CELLULAR UTILITY EASEMENT
C/L OF EXISTING 8' WIDEPROPERTY LINE
PROPERTY LINE
PR
OP
ER
TY LIN
E
LEASE AREA
EXISTING U.S. CELLULAR 30' X 20'
SEE T-201 FOR DETAILS
EXISTING WATER TOWER;
EXISTING CLIMBING LADDER
EXISTING TOWER LEG
BUILDING
EXISTING
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
C-1
02.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
778335)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
A-101A
SHELTER INTERIOR LAYOUT
22" x 34" - 3/4" = 1'-0"
SCALE: 11" x 17" - 3/8" = 1'-0"
D
C
SH
EL
TE
R I
NT
ER
IOR
PL
AN
EXISTING LTE RACKS TO BE REMOVED
EXISTING AUX EQUIPMENT RACK
POWER BAY RACKS TO BE REPLACED
EXISTING BATTERY BACKUP AND B
SEE A-501 FOR DETAILS
RAYCAP SPD AND EXISTING RF GROUND BAR;
MECHANICAL CONNECTION BETWEEN PROPOSED
PROPOSED GROUND LEAD WITH 2 LUG
SEE T-002 FOR DETAILS
USE PROVIDED HARDWARE KIT FOR INSTALLATION;
PROPOSED WALL MOUNTED RAYCAP SPD (TYP. OF 3);
CABLE TRAY FOR CABLE ROUTING
CONTRACTOR TO USE EXISTING OVERHEAD
SEE A-501 FOR DETAILS
AND EXISTING OVERHEAD CABLE TRAY;
TRAYS BETWEEN PROPOSED RAYCAP SPD
PROPOSED VERTICAL AND HORIZONTAL CABLE
HYBRID CABLE (TYP. OF 3)
PROPOSED 1-1/4" EUPEN
GROUND BAR
REMOVED POST INTEGRATION
EXISTING LTE DIPLEXERS TO BE
SEE A-501 FOR DETAILS
SECURED TO BUILDING EXTERIOR;
PROPOSED LTE GPS ANTENNA
BE ROUTED FROM AUX RACK
PROPOSED LTE GPS CABLE TO
NO ICE BRIDGE POST
SECURED TO SHELTER
ICE BRIDGE
EXISTING SHROUD COVERED
ANTENNA TO REMAIN
EXISTING CDMA GPS
BE REMOVED POST INTEGRATION
ASSOCIATED RADIO EQUIPMENT TO
EXISTING LTE EQUIPMENT RACKS AND
TO BE INSTALLED BY OTHERS
BACKUP AND POWER BAY RACKS
FUTURE REPLACEMENT BATTERY
SEE T-502 FOR QUANTITY
EXISTING CABLE TRAY;
ROUTE ACROSS PROPOSED AND
POWER BAY RACK TO RAYCAP;
PROPOSED DC POWER JUMPERS FROM
SEE T-502 FOR QUANTITY
AND EXISTING CABLE TRAY;
INNERDUCT (PRIMUS # PDPU1000) ACROSS PROPOSED
ROUTE JUMPERS INSIDE 1" DIA. ORANGE PLENUM
PROPOSED FIBER JUMPERS FROM AUX RACK TO RAYCAP;
RACK
AUX
RACK
EQUIP
CDMA
RACK
EQUIP
LTE
RACK
EQUIP
LTE
RACK
BAY
POWER
RACK
BACKUP
BATTERY
A/C PANEL
TE
LC
O B
OA
RD
HVACHVAC
RACK
TELCO
SEE A-501 FOR DETAILS
(BBU) TO BE INSTALLED IN EXISTING AUX RACK;
PROPOSED ERICSSON 6630 BASEBAND UNIT
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
A-1
01.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
SITEPRO1 PART #: CR-9141
HOLD DOWN CLAMP KIT;
MECHANICAL CONNECTION (TYP.)
COAX PORT
CABLE TRAY TO
EXISTING OVERHEAD
VERIFY LENGTH IN FIELD
SITEPRO 1 PART #: CR-12-Y;
12" VERTICAL CABLE TRAY;
VERIFY LENGTH IN FIELD
SITEPRO 1 PART #: CR-12-Y;
12" OVERHEAD CABLE TRAY TO EXISTING;
VERIFY LENGTH IN FIELD
SITEPRO 1 PART #: CR-12-Y
12" HORIZONTAL CABLE TRAY (TYP.);
RAYCAP SPDs AND CABLE TRAY (TYP.)
APPROVED EQUAL FOR MOUNTING
ANCHOR WITH 1-1/2" MIN. EMBED OR
1/4" DIA. SIMPSON STRONG-TIE TITEN HD
SITEPRO1 PART #: CR-STAND
END SUPPORT KIT;
INTERIOR GROUND BAR
SHELTER COAX PORT
COAX PORT
BAND OF SERVICE
EACH RAYCAP SPD WITH SPECIFIC
GENERAL CONTRACTOR TO LABEL
SECURED TO SHELTER WALL;
PROPOSED RAYCAP SPD
POWER CABLE (TYP.)
PROPOSED HYBRID OR
(TYP.)
SPDs AND CABLE TRAY BONDING
STRANDED CU WIRE FOR RAYCAP
#6 AWG THHN GREEN INSULATED
A-501
SH
EL
TE
R D
ET
AIL
S
A PROPOSED RAYCAP SPD LOCATION
C PROPOSED GPS ANTENNA LOCATION
SEE T-002 FOR DETAILS
USE PROVIDED HARDWARE KIT FOR INSTALLATION;
PROPOSED WALL MOUNTED RAYCAP SPD (TYP. OF 3);
RIGHT
SHELTER; SEE DETAIL TO THE
MOUNTED TO EXTERIOR OF
PROPOSED LTE GPS ANTENNA
REMAIN
EXISTING GPS ANTENNA TO
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
A-5
01.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
SEE SHELTER INTERIOR LAYOUT FOR RAYCAP SPD / CABLE TRAY ORIENTATION.1.
NOTE:
BHORIZONTAL AND VERTICAL CABLE TRAY INSTALLATION
DGPS ANTENNA MOUNTING
GPS ANTENNA
GPS MOUNTING BASE
6" M
IN. C
LE
AR
HOLLOW WALL: SITE PRO 1 #: HWK12 OR APPROVED EQUAL
SOLID WALL: SITE PRO 1 #: SWK12 OR APPROVED EQUAL
WALL MOUNT HARDWARE KIT;
SITE PRO 1 #: GPS1 OR APPROVED EQUAL
GPS WALL MOUNT;
SHELTER
EQUIPMENT
19" BASEBAND UNIT
(TYP. OF 2)
MOVABLE BRACKETS
EERICSSON BASEBAND UNIT (BBU)
1RACK UNITS:
14.33 LBSWEIGHT:
1.75" x 19.0" x 13.78" (H x W x D)DIMENSIONS:
: BBU 6630MODEL
: ERICSSONMANUFACTURER
T-001
AN
TE
NN
A S
PE
CIF
ICA
TIO
NS
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
T-0
01.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
AANTENNA SPECIFICATIONS
BOTTOM VIEW
FRONT VIEW SIDE VIEW
FRONT VIEW SIDE VIEW
PLAN VIEW
SIDE VIEWFRONT VIEW
PLAN VIEW
SIDE VIEWFRONT VIEW
PLAN VIEW
SIDE VIEWFRONT VIEW
PLAN VIEW
T-002
EQ
UIP
ME
NT
SP
EC
IFIC
AT
ION
S
ARAYCAP SURGE PROTECTOR DEVICE (SPD)
19.95 LBSWEIGHT:
20.6" x 18.9" x 5.8" (H x W x D)DIMENSIONS:
: RUSDC-6267-PF-48MODEL
: RAYCAPMANUFACTURER
16.1"
18.9
"
20.6
"
5.8"
H-FRAME OR WALL MOUNT
ENCLOSURE MOUNTS FOR
REMOVE BRACKET AND USE
MOUNTING BRACKET INCLUDED;
MOUNTING TO POLE
V-CLAMP FOR
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
T-0
02.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
DREMOTE RADIO UNIT (RRU)
UP WITHIN 48 HOURS OF INSTALLATION.
REMOTE RADIO UNITS MUST BE POWERED 1.
NOTES:
75 LBS.WEIGHT:
15.0" x 13.2" x 11.1" (H x W x D)DIMENSIONS:
: RRU 8843MODEL
: ERICSSONMANUFACTURER
13.2" 11.1"
15.0
"
DUAL ERS BRACKET
THIS S
PA
CE I
NTE
NTIO
NALLY L
EFT B
LA
NK
UP WITHIN 48 HOURS OF INSTALLATION.
REMOTE RADIO UNITS MUST BE POWERED 1.
NOTES:
ELICENSED ASSISTED ACCESS (LAA)
12.2 LBS.WEIGHT:
7.9" x 7.9" x 4.7" (H x W x D)DIMENSIONS:
: RRU 2205MODEL
: ERICSSONMANUFACTURER
4.7"7.9"
7.9
"
AND POLE MOUNT
RRU ADAPTER PLATE
CREMOTE RADIO UNIT (RRU)
7.2"
19.7
"
RRU SUPPORT KIT
50.7 LBSWEIGHT:
19.7" x 17" x 7.2" (H x W x D)DIMENSIONS:
: RRU11MODEL
: ERICSSONMANUFACTURER
17"
BREMOTE RADIO UNIT (RRU)
10.5"
17.9
"
DUAL ERS BRACKET
13.2"
70.5 LBSWEIGHT:
17.9" x 13.2" x 10.5" (H x W x D)DIMENSIONS:
: RADIO 4449MODEL
: ERICSSONMANUFACTURER
UP WITHIN 48 HOURS OF INSTALLATION.
REMOTE RADIO UNITS MUST BE POWERED 1.
NOTES:
UP WITHIN 48 HOURS OF INSTALLATION.
REMOTE RADIO UNITS MUST BE POWERED 1.
NOTES:
M10
M8
M4
SINGLE UNIT
DOUBLE UNIT
BACK VIEW
ISOMETRIC VIEW
PLATE MOUNTING PATTERN
DUAL RADIO ATTACHMENT
T-003
MO
UN
TIN
G S
PE
CIF
ICA
TIO
NS
INCLUDED WITH RAYCAP SPD.
: MOUNTING BRACKETMODEL
: RAYCAPMANUFACTURER
ARAYCAP SURGE PROTECTOR DEVICE (SPD) MOUNT
HARDWARE
MOUNTING
HOLES FOR
HARDWARE
MOUNTING
HOLES FOR
NUT
LOCK WASHER
WASHER
BOLT
WASHER
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
T-0
03.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
THIS
SPACE IN
TENTIONALLY
LEFT BLANK
27.1 LBSWEIGHT:
11.8" x 11.8" x 1.2" (H x W x D)DIMENSIONS:
: SXK1072892/1MODEL
: ERICSSONMANUFACTURER
DRRU ADAPTER PLATE AND POLE MOUNT
8.9"
5.7"
10.4
"
6.6
"
5.7"
1.2" 1.2" 1.2"
5.1" 4.3
"
ALL HARDWARE INCLUDED
4LBS. 6.5 OZ.WEIGHT:
SXK 107 2839/2MODEL:
ERICSSONMANUFACTURER:
SINGLE SUPPORT KIT FOR DUAL MOUNT
EXPANSION KIT ORDERED IN ADDITION TO
11 LBSWEIGHT:
: SXK 107 2839/1MODEL
: ERICSSONMANUFACTURER
CREMOTE RADIO UNIT (RRU) SUPPORT KIT
B
1.18"
3.15"
4.3
3"
5.12"
DUAL ERS BRACKET
SUPPLIED IN THE PACKAGE.
BOLTS FOR ATTACHING TWO ERS UNITS ARE
POLE, WALL, ANGLE TOWER OR SQUARE TUBE.
CC 30 MM AND/OR CC 80 MM., EITHER TO A
HEAVY ERS UNITS WITH A HOLE PATTERN OF
BRACKET FOR ATTACHING TWO STANDARD OR
3.75 LBSWEIGHT:
SXK 109 1973/2MODEL:
ERICSSONMANUFACTURER:
T-201
SIT
E E
LE
VA
TIO
N
ASITE ELEVATION
22" x 34" - 1" = 10'-0"
SCALE: 11" x 17" - 1" = 20'-0"
CONTRACTOR TO VERIFY LIGHTNING ROD EXTENDS 2' MIN. ABOVE ALL ANTENNAS & EQUIPMENT.2.
CONTRACTOR TO VERIFY HEIGHT AND DIRECTION OF ANTENNAS WITH PROJECT MANAGER.1.
NOTES:
C U.S. CELLULAR ALPHA SECTOR ANTENNAS
D U.S. CELLULAR BETA SECTOR ANTENNAS
E U.S. CELLULAR GAMMA SECTOR ANTENNASB EXISTING SITE ELEVATION
TO
P O
F E
XIS
TIN
G W
AT
ER
TO
WE
R @
15
0.0
' A
BO
VE
T.O
.C.
C/L
OF
U.S
. C
EL
LU
LA
R A
NT
EN
NA
S @
153.0
' A
BO
VE
T.O
.C.
HIG
HE
ST
AP
PU
RT
EN
AN
CE
@ 1
67
.0' A
BO
VE
T.O
.C.
SEE A-101 FOR DETAILS
EQUIPMENT SHELTER;
EXISTING U.S. CELLULAR
EQUIPMENT SHELTER
EXISTING OTHER CARRIER
EXISTING WATER TOWER
SEE T-501 FOR DETAILS
U.S. CELLULAR ANCILLARY EQUIPMENT;
MOUNTS, SEE T-301 FOR DETAILS
ANTENNAS TO BE INSTALLED ON NEW
U.S. CELLULAR LTE & LAA
ANTENNAS TO BE REMOVED
(3) EXISTING U.S. CELLULAR CDMA
TO BE REMOVED
LTE ANTENNA
ALPHA SECTOR
TO BE REMOVED
CDMA ANTENNA
ALPHA SECTOR
TO BE REMOVED
LTE ANTENNA
GAMMA SECTOR
TO BE REMOVED
CDMA ANTENNA
GAMMA SECTOR
TO BE REMOVED
CDMA ANTENNA
BETA SECTOR
TO BE REMOVED
LTE ANTENNA
BETA SECTOR
MANAGEMENT ROUTE
FOLLOW THE APPROVED CABLE
ALL CABLES ARE REQUIRED TO
FROM THE TOWER
HARDWARE, ETC. SHALL BE REMOVED
ALL UNUSED COMPONENTS, CABLES,
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
T-2
01.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
T-301
AN
TE
NN
A C
ON
FIG
UR
AT
ION
ALL ANTENNA AZIMUTHS TO BE FROM TRUE NORTH.1.
NOTE:
NORTH
AEXISTING ANTENNA LAYOUT
22" x 34" - 1/2" = 1'-0"
SCALE: 11" x 17" - 1/4" = 1'-0"B
PROPOSED ANTENNA LAYOUT
22" x 34" - 1/2" = 1'-0"
SCALE: 11" x 17" - 1/4" = 1'-0"
NORTH
SEE T-002 FOR DETAIL
PROPOSED REMOTE RADIO (TYP. OF 9);
CONTRACTOR MAY NEED ADDITIONAL 9'-0" LONG MAST PIPES FOR TEMPORARY RELOCATION OF LTE ANTENNAS.2.
ALL ANTENNA AZIMUTHS TO BE FROM TRUE NORTH.1.
NOTES:
20°
LTE
SEE T-002 FOR SPECIFICATIONS
AND MOUNTING HARDWARE (TYP. OF 3);
DIRECTIONAL ANTENNA ON NEW MAST PIPE
PROPOSED LAA RADIO WITH BUILT-IN
UPPE
R C
LIM
B L
AD
DE
R
60°
CDMA
115°
LTE
165°
CD
MA
265°
LTE
300°
CDMA
TO BE REMOVED (TYP. OF 3)
LTE PANEL ANTENNA & BIAS-T
EXISTING U.S. CELLULAR
UPPER ANTENNA HANDRAIL
OTHER CARRIER(S)
EXISTING ANTENNA, TYP.
UPPE
R C
LIM
B L
AD
DE
R
TO BE REMOVED
CDMA PANEL ANTENNA
EXISTING U.S. CELLULAR
TO BE REMOVED
CDMA PANEL ANTENNA
EXISTING U.S. CELLULAR
EMPTY MAST PIPE
EMPTY MAST PIPE
EXISTING OMNI ANTENNA
EXISTING LIGHTNING ROD
TO BE REMOVED
CDMA PANEL ANTENNA
EXISTING U.S. CELLULAR
EXISTING LIGHTNING ROD
EXISTING CABLE ROUTECABLE ROUTE
TO BE INSTALLED ALONG EXISTING
PROPOSED U.S. CELLULAR CABLES
30°
AW
S/L
TE
30°
PCS/L
TE
30°LA
A
280°
PCS/LTE
280°
AWS/LTE
280°
LAA
130°
PCS/LTE
130°
LAA
130°
AW
S/LTE
SPECIFICATIONS
SEE T-001 FOR
HARDWARE (TYP. OF 6);
PIPE AND MOUNTING
ANTENNA ON NEW MAST
PROPOSED LTE PANEL
SEE T-002 FOR DETAIL
PROPOSED RAYCAP SPD (TYP. OF 3);
REQUIRED ON ALL EXTERIOR PIPES
WELDED/FITTED END CAPS ARE
(DLM PREFEREED SHOP PAINTER IS IPS IN HUGO, MN)
MAST PIPES MUST BE SHOP PAINTED AND INSPECTED.
TAPE AS AN ALTERNATIVE TO PAINTING. ALL ANTENNAS AND
MATCH. CABLES MAY BE WRAPPED WITH A COLOR MATCHING
CABLES, AND HARDWARE SHALL BE PAINTED TO COLOR
ALL ANTENNAS, MAST PIPES, EXTERIOR COMPONENTS,
"U.S. CELLULAR" EQUIPMENT
CLEARLY LABELING EQIUPMENT AS
LABELED WITH WEATHERPROOF LABELS,
AND CABLES AT ALL PENETRATIONS SHALL BE
ALL ANTENNAS, RADIOS, JUNCTION BOXES,
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
T-3
01.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
A1
A2
B1
B2
G1
G2
A3
A1
A2
G1
G3
G2
B2
B1
B3
T-401
CIT
Y I
NS
TA
LL
AT
ION
RE
QU
IRE
ME
NT
S
CITY INSTALLATION REQUIREMENTS
AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER.
PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED
THE CONTRACTOR AND SUBCONTRACTORS SHALL PROTECT EXISTING IMPROVEMENTS, K.
(KLM PREFERRED COATING REPAIR PAINTER IS SLACK PAINTING).
ALL PAINT COATINGS SHALL BE PROTECTED AND PROPERLY REPAIRED BY PROFESSIONAL PAINTER. J.
WITH WEATHERPROOF LABELS, CLEARLY LABELING EQUIPMENT AS "U.S. CELLULAR" EQUIPMENT.
ALL ANTENNAS, RADIOS, JUNCTION BOXES, AND CABLES AT ALL PENETRATIONS SHALL BE LABELED I.
DAMAGE OF SURROUNDING INTACT PAINT SYSTEM(S).
PROTECT ALL AREAS ADJACENT TO WELDING AND/OR GRINDING OPERATIONS TO PREVENT H.
STARTED. COMPRESSION STYLE ATTACHMENT METHODS ARE REQUIRED.
REQUIRE WELDING ARE TO BE ABRASIVE BLASTED OR GROUND BEFORE ANY WELDING IS
RESPONSIBLE TO ADEQUATELY REMOVE ALL COATING BEFORE WELDING. ALL AREAS THAT
NO WELDING OVER COATED STEEL SURFACES IS PERMISSIBLE. THE CONTRACTOR IS G.
INSTALLED AS NEATLY/DISCRETELY AS POSSIBLE.
CABLES SHALL BE MANUFACTURED OR TERMINATED TO THE APPROPRIATE LENGTH AND F.
COLOR MATCH.)
WHAT THEY HAVE ON FILE, BUT IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO ENSURE
CONTRACTOR IS TO FIELD MATCH AND FIELD VERIFY PAINT COATING COLOR. (KLM WILL PROVIDE E.
OR HAND-RAILINGS.
TRIPPING HAZARD OR INTERFERE WITH ACCESS TO THE CLIMBING LADDERS, MAN-WAY HATCHES,
ALL NEW AND EXISTING COMPONENTS/CABLES SHALL BE INSTALLED SO AS NOT TO CREATE A D.
MATCH THE TOWER.
EXTERIOR U-BOLT OR COMPRESSION MOUNT CONTACT POINTS ALSO USE COLORED TAPE TO
ALL CLAMPS, ANGLE ADAPTERS, ETC. AT ALL PAINTED CONTACT POINTS. ON ALL PAINTED
INCLUDE NEOPRENE, NYLON WASHERS, AND A METAL SHIM AS NECESSARY BENEATH AND AROUND
ON ALL NEW AND EXISTING METAL-TO-METAL CONTACT POINTS:C.
CONDITION. THIS DOCUMENTATION MUST BE SENT TO THE CITY AND KLM FOR THEIR RECORDS.
MUST HAVE DRAWINGS EDITED TO MATCH AND SA OF HANDRAIL RERUN TO MATCH THE AS-BUILT
PIPES ARE NEEDED FOR MOUNTING OF ANY EQUIPMENT (RRU, TMA, RAYCAPS, ETC.), CONTRACTOR
ALL EQUIPMENT MUST BE MOUNTED AS STATED IN CONSTRUCTION DRAWINGS, IF ANY EXTRA MAST B.
ALL UNUSED CABLES AND JUMPERS SHALL BE REMOVED FROM THE SITE.A.
KLM PAINTING SPECIFICATIONS
COLOR SELECTION(S).
BE OBTAINED FROM THE PAINT MANUFACTURER FOR THE RESERVOIR OWNER TO CONFIRM
EXISTING INTERIOR DRY COLOR TO THE OWNER'S SATISFACTION. COLOR DRAWDOWNS SHALL
SYSTEM AT ANY INDIVIDUAL SPOT LOCATION SHALL BE 10.5 MILS. THE COLOR SHALL MATCH THE
MILS WITH AN AVERAGE OF 13.0 MILS. THE MINIMUM DRY FILM THICKNESS OF THE COATING
INCLUDING THE PRIMER, INTERMEDIATE AND FINISH COATS SHALL BE 10.5 MILS MINIMUM - 15.5
PLUS SERIES N140, 4.0 - 6.0 MILS DRY FILM THICKNESS. THE TOTAL DRY FILM THICKNESS
SHALL BE 6.5 MILS MINIMUM. THE INTERIOR DRY FINISH COAT SHALL BE TNEMEC POTA-POX
DFT OF THE PRIMER PLUS INTERMEDIATE AT ANY INDIVIDUAL SPOT MEASUREMENT LOCATION
COAT SHALL BE TNEMEC POTA-POX PLUS SERIES N140, 4.0-6.0 MILS DRY FILM THICKNESS. THE
MEASUREMENT LOCATION SHALL BE 2.5 MILS MINIMUM. THE INTERIOR DRY INTERMEDIATE
N140, 4.0-6.0 MILS DRY FILM THICKNESS. THE DFT OF THE PRIMER AT ANY INDIVIDUAL SPOT
SYSTEM ON THE TANK. THE INTERIOR WET PRIMER SHALL BE TNEMEC POTA-POX PLUS SERIES
THE INTERIOR WET COATING SYSTEM SHALL BE COMPATIBLE WITH THE EXISTING COATING ii.
CLEANING METHODS.
EDGES OF EXISTING COATING, AT SPOT BLASTED AREAS, USING SSPC-SP-3 POWER TOOL
SUPPORT BRACKETS AND HANDRAIL, TO AN SSPC-SP-10 NEAR WHITE METAL BLAST. FEATHER
INSTALLATION OF NEW EXTERIOR AND INTERIOR DRY ITEMS, INCLUDING ANTENNA AND CABLE
SPOT BLAST THE INTERIOR WET AREA OF THE TANK AT LOCATIONS DAMAGED DURING i.
INTERIOR WET SURFACE SPOT REPAIR AND RE-COATING:O.
RESERVOIR OWNER TO CONFIRM COLOR SELECTION(S).
COLOR DRAWDOWNS SHALL BE OBTAINED FROM THE PAINT MANUFACTURER FOR THE
THE COLOR SHALL MATCH THE EXISTING INTERIOR DRY COLOR TO THE OWNER'S SATISFACTION.
THICKNESS OF THE COATING SYSTEM AT ANY INDIVIDUAL SPOT LOCATION SHALL BE 10.5 MILS.
BE 10.5 MILS MINIMUM - 15.5 MILS WITH AN AVERAGE OF 13.0 MILS. THE MINIMUM DRY FILM
TOTAL DRY FILM THICKNESS INCLUDING THE PRIMER, INTERMEDIATE AND FINISH COATS SHALL
COAT SHALL BE TNEMEC POTA-POX PLUS SERIES N140, 4.0-6.0 MILS DRY FILM THICKNESS. THE
MEASUREMENT LOCATION SHALL BE 2.5 MILS MINIMUM. THE INTERIOR DRY INTERMEDIATE
N140, 4.0-6.0 MILS DRY FILM THICKNESS. THE DFT OF THE PRIMER AT ANY INDIVIDUAL SPOT
SYSTEM ON THE TANK. THE INTERIOR DRY PRIMER SHALL BE TNEMEC POTA-POX PLUS SERIES
THE INTERIOR DRY COATING SYSTEM SHALL BE COMPATIBLE WITH THE EXISTING COATING i.
INTERIOR DRY SPOT REPAIR AND RE-COATING:N.
EXTERIOR COATING SHALL BE BY BRUSH AND ROLLER ONLY.ii.
MANUFACTURER FOR THE RESERVOIR OWNER TO CONFIRM COLOR SELECTION(S).
TO THE OWNER'S SATISFACTION. COLOR DRAWDOWNS SHALL BE OBTAINED FROM THE PAINT
INDIVIDUAL SPOT LOCATION SHALL BE 12.5 MILS. COLOR SHALL MATCH THE EXISTING COATING
AVERAGE OF 13.0 MILS DFT. THE MINIMUM DRY FILM THICKNESS OF THE COATING AT ANY
INCLUDING THE PRIMER AND THE FINISH COAT SHALL BE 11 MILS MINIMUM-17.0MILS WITH AN
SERIES 1075-COLOR TO MATCH THE TOWER, 3.0-5.0 MILS DFT. THE TOTAL DRY FILM THICKNESS
SHALL BE 9.0 MILS MINIMUM. THE EXTERIOR FINISH COAT SHALL BE TNEMEC ENDURASHIELD II
PRIMER PLUS THE INTERMEDIATE COAT AT ANY INDIVIDUAL SPOT MEASUREMENT LOCATION
EPOXOLINE SERIES 66 OR TNEME-FASCURE SERIES 161, 4.0-6.0 MILS DFT. THE DFT OF THE
SERIES 161, 4.0-6.0 MILS DFT. THE EXTERIOR INTERMEDIATE COAT SHALL BE TENEMEC HI-BUILD
EXTERIOR PRIMER SHALL BE TNEMEC HI-BUILD EPOXOLINE SERIES 66 OR TNEME-FASCURE
COATING SYSTEM SHALL MATCH THE EXISTING COATING SYSTEM ON THE TOWER. THE
SPOT PRIME AND FINISH COAT REPAIRED AREAS AS SPECIFIED BY MANUFACTURER. THE i.
EXTERIOR SURFACE SPOT REPAIR AND RE-CAOTING:M.
SPECIFICATIONS APPLY TO BOTH SHOP AND FIELD COATING.L.
BRUSH-BLAASTED PRIOR TO COATING.
IF GALVANIZED MATERIALS USED, THE GALVANIZED SURFACES MUST BE SOLVENT WIPED AND K.
TO THE CABLES AS DIRECTED BY THE ENGINEER.
COAX CABLE BONDER & SEALER (PRODUCT NO. 1138). AFTER PRIMING APPLY ONE (1) FINISH COAT
RECOMMENDED SOLVENT. PRIME THE CABLES AND JUMPER CABLES WITH TWO (2) COATS OF X-I-M
EXPOSED COAXIAL CABLES: PRIOR TO PRIMING, SOLVENT WIPE ALL EXPOSED CABLES WITH THE J.
COLOR. CABLES MAY REQUIRE SCARIFICATION PRIOR TO COATING.
BRACKETS AND SUPPORTS, SHOULD BE PAINTED TO MATCH EXISTING TANK COATING SYSTEM AND
EXISTING TANK COLOR. ALL ITEMS ATTACHED DIRECTLY TO THE TANK, SUCH AS MOUNTING
ANTENNAS, EXTERIOR COAX CABLES AND EXTERIOR JUMPER CABLES TO BE PAINTED TO MATCH I.
MISSED AREAS.
FINISH COAT SHALL BE UNIFORM IN COLOR AND SHEEN WITHOUT STREAKS, LAPS, RUNS, SAGS OR H.
SEAMS, AND OTHER IRREGULARITIES IN THE SURFACE.
THOROUGHLY WORKED INTO AND AROUND ALL SEAMS, WELDS, BOLT ASSEMBLIES, PLATE OVERLAP
APPLY BY BRUSH ONE (1) ADDITIONAL COAT OF PRIMER TO ENSURE A UNIFORM COAT OF PRIMER G.
PRIME COAT MUST BE APPLIED WITHIN 8 HOURS OF ABRASIVE BLASTING.F.
CONTRACTOR SHALL ACCEPT THE ENGINEER'S INTERPRETATION AS FINAL AND BINDING.
CONDITIONS ARE QUESTIONABLE, THE ENGINEER SHALL MAKE THE DECISION AND THE
DAMP SURFACES, AND SHALL NOT BE APPLIED IN RAIN, SNOW, FOG, OR MIST. IF WORKING
WET BULB AIR TEMPERATURE READING. COATING SHALL NOT BE APPLIED TO DUSTY, WET, OR
AIR AND SURFACE TEMPERATURES ARE ABOVE THE MANUFACTURER'S RECOMMENDED MINIMUM
OF THE COATING. PROCEED WITH SURFACE PREPARATION AND COATING APPLICATION ONLY WHEN
NO COATING SHALL BE PERMITTED WHEN THE RELATIVE HUMIDITY IS EXPECTED TO EXCEED 85% E.
DUST FREE, INSPECTED AND APPROVED BY THE ENGINEER.
BEFORE ANY PRIMER OR COATING IS APPLIED, METAL SURFACES SHALL BE COMPLETELY DRY, D.
COATING AT SPOT BLASTED AREAS USING SSPC-SP-3 POWER TOOL CLEANING METHODS.
AREAS DAMAGED BY STRUCTURAL REPAIRS OR MODIFICATIONS. FEATHER EDGES OF EXISTING
SP-10 NEAR WHITE METAL BLAST CLEAN. THIS WORK INCLUDES ALL NEW ITEMS AND AT OTHER
THE COATING HAS BEEN DAMAGED BY STRUCTURAL REPAIRS AND MODIFICATIONS, TO AN SSPC-
UNDER THE DIRECTION OF THE ENGINEER, SPOT REPAIR THE TANK AND TOWER SURFACES WHERE C.
NOT USE HYDROCARBON SOLVENTS ON SURFACES TO BE COATED WIT WATER-BASED COATING.
REMOVE ALL SURFACE CONTAMINANTS IN ACCORDANCE WITH SSPC-SP-1 SOLVENT CLEANING. DO B.
REQUIRED. SURFACE PREPARATION AND PAINTING REQUIREMENTS ARE AS FOLLOWS:
PAINTING OF ALL NEW ITEMS AND REPAIR OF ALL DAMAGED AREAS OF THE TOWER WILL BE A.
THIS S
PA
CE I
NT
EN
TIO
NA
LL
Y L
EF
T B
LA
NK
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
T-4
01.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
T-501
INS
TA
LL
AT
ION
DE
TA
ILS
E
REMOVED
ANTENNA TO BE
EXISTING LTE
REMOVED
ANTENNA TO BE
EXISTING LTE
REMOVED
ANTENNA TO BE
EXISTING LTE
TO REMAIN
ANTENNA
EXISTING CDMA
TO REMAIN
ANTENNA
EXISTING CDMA
TO REMAIN
ANTENNA
EXISTING CDMA
EXISTING ANTENNA LOCATIONS
TO PROTECT TOWER COATINGS
ANGLE CONNECTION AND HANDRAIL
NEOPRENE SHALL BE USED BETWEEN
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
T-5
01.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
CBOLTED ANGLE CONNECTION
(ORDERED SEPARATELY)
1-1/2" O.D. TO 3-1/2" O.D. PIPE
1-1/4"
1-1/4"
5-1/2"
8"
ASSOCIATED HARDWARE (TYP.)
5/8" DIA. GALV. BOLT AND
L4" x 4" x 3/8" x 0'-8" LONG
OR APPROVED EQUAL
SITE PRO 1 #: X-100064
4" V-CLAMP HALF;
ASSOCIATED HARDWARE (TYP.)
1/2" DIA. GALV. THREADED ROD AND
2"
4"
2"
SEE ANTENNA PLAN FOR QTY. AND LAYOUT
PANEL ANTENNA (TYP.);
ROUTE CABLES ALONG ROUND MEMBERS ON TOWER STANDOFFS OR TRAP BOXES AND SNAP-IN HANGERS; SEE T-502 FOR DETAIL.1.
NOTE:
AANTENNA MOUNTING
ROOFTOP RAILING
1'-
0" M
AX
AND RAILING TO PROTECT TOWER COATING (TYP.)
NEOPRENE GASKET BETWEEN CROSS OVER CONNECTIONS
SEE DETAIL BELOW
BOLTED ANGLE CONNECTION (TYP.);
THAN ANTENNA LENGTH
MAST PIPE LENGTH TO BE 12" LONGER
PIPE ORDERED SEPARATELY;
2-1/2" SCH. 40 (2-7/8" O.D.) GALV. MAST
THIS S
PA
CE I
NTE
NTIO
NALLY L
EFT B
LA
NK
DDETAIL NOT APPLICABLE
OR POWER CABLE (TYP.)
PROPOSED HYBRID (POWER/FIBER)
SEE T-002 FOR DETAIL
REMOTE RADIO (TYP.);
BANCILLARY EQUIPMENT MOUNTING
THIS DETAIL IS A GENERAL SCHEMATIC, SEE ANTENNA LAYOUT FOR ACTUAL TOWER ORIENTATION AND EQUIPMENT QUANTITIES.3.
CONTRACTOR TO INSTALL INNERDUCT SO THAT THE ENDS TERMINATE EITHER HORIZONTALLY OR DOWN TO PREVENT WATER INGRESS.
ROUTE POWER AND FIBER CABLES FROM RAYCAP SPD TO REMOTE RADIOS IN 1-1/4" INNERDUCT (TYP. EACH SECTOR); 2.
ROUTE CABLES ALONG ROUND MEMBERS ON TOWER STANDOFFS OR TRAP BOXES AND SNAP-IN HANGERS; SEE T-502 FOR DETAIL.1.
NOTE:
SEE T-003 FOR DETAIL
(IF APPLICABLE);
DUAL MOUNT B5 REMOTE RADIO
ROOFTOP RAILING
SEE T-002 FOR DETAIL
RAYCAP SPD;
PROTECT TOWER COATING (TYP.)
OVER CONNECTIONS AND RAILING TO
NEOPRENE GASKET BETWEEN CROSS
SEE DETAIL BELOW
BOLTED ANGLE CONNECTION (TYP.);
EQUIPMENT ABOVE ROOFTOP
MINIMIZE HEIGHT OF
TO HANDRAIL INTERIOR (TYP.)
2" SCH. 40 (2-3/8" O.D.) GALV. MAST PIPE SECURED
REQUIRED ON ALL EXTERIOR PIPES
WELDED/FITTED END CAPS ARE
-48V DC Power Connections
1
2
3
4
5
6
ROW
BASE
ROW
MID
ROW
TOP
13a13b
14a14b
TXRX
TXRX 15a
15b
RX
TX16a
RX
TX16b
17a17b
RX
TX18a
18b
RX
TX
12b
12a
RX
TX
11b
11a
RX
TX
10b
10a
RX
TX
9b
9a
RX
TX
8b
8a
RX
TX
7b
7a
TXRX
1a
1b
RX
TX
2a
2b
RX
TX
3a
3b
RX
TX
4a
RX
T-502C
JUMPER ATTACHMENT
7/8" MATING HANGER
ACCEPTS 0.16" TO 0.55" O.D. CABLES
UNIVERSAL BARREL CUSHION
: BCU78XMODEL
7/8" STACKABLE SNAP-IN HANGER
: 78SS-AMODEL
FITS 1-1/2" DIA. TO 3" DIA. ROUND MEMBERS
UNIVERSAL TOWER STANDOFF KIT
: STK2-UMODEL
: SITE PRO 1MANUFACTURER
OR APPROVED EQUIVALENT
SITE PRO 1 PART # STK2-U
UNIVERSAL STANDOFF KIT,
APPROVED EQUIVALENT
SITE PRO 1 PART # 78SS-A OR
7/8" STACKABLE SNAP-IN HANGER,
7/8"
CABLES; MATING HANGER SIZE
ACCEPTS 0.16" TO 0.55" O.D.
SITEPRO1 PART # BCU78X;
UNIVERSAL BARREL CUSHIONS,
13a 13b 14a 14b
TX RX TX RX
15a 15b
RXTX
16a
RXTX
16b 17a 17b
RXTX
18a 18b
RXTX
12b12a
RXTX
11b11a
RXTX
10b10a
RXTX
9b9a
RXTX
8b8a
RXTX
7b7a
TX RX
1a 1b
RXTX
2a 2b
RXTX
3a 3b
RXTX
4a 4b
RXTX
5a 5b
RXTX
6a 6b
RXTX
TOP ROW
MID ROW
BASE ROW
EFIBER LABEL
VIEW INSIDE OF LID
BLANKS FOR NOTES
FIBER LABEL WITH
COMPRESSION FOAM WITH BLANKS FOR NOTES
DC CONNECTION LABEL
CA
BL
E D
ET
AIL
S
DRAYCAP SURGE PROTECTOR DEVICE (SPD) CABLING
VIEW INSIDE OF RAYCAP SPD
TERMINAL BLOCK 6-20 AWG (TYP.)
(TYP. OF 6)
STRIKESORB MODULE
EMPTY PORT
(5) BEND PROTECTORS
STRIKESORB MODULES
LABELING ON
IDENTIFICATION
PROVIDE SECTOR
CONTRACTOR TO
WIRES
SHIELD AND DRAIN
GROUND STRIP FOR
FIBER LABEL
FROM SOURCE
POWER JUMPER CABLES
GROUND LEAD
(IF APPLICABLE)
FIBER CABLES
OUTSIDE OF RAYCAP SPD
FIBER CABLES ARE NOT EXPOSED
ENTERS INTO PORT AND ITS POWER OR
WHERE HYBRID CABLE SHEATHING
CONTRACTOR TO INSTALL IN A MANNER
(1) EUPEN POWER CABLE;
(1) EUPEN HYBRID CABLE OR
(IF APPLICABLE)
CABLES FROM SOURCE
FIBER OPTIC JUMPER
(IF APPLICABLE)
FIBER LANDING
FIBER COUPLERS ON
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
T-5
02.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
BEUPEN HYBRID CABLE
MAXIMUM CABLE LENGTH OF 410'.
NON-ARMORED ENDS ARE 3" IN LENGTH (2" O.D.).
SHIPPED WITH 4' PROTECTED JACKET (2.25" O.D.) AT EACH END.
CORRUGATED ALUMINUM SHIELDING WITH UV RESISTANT PE JACKET.
1-1/4" HYBRID FIBER OPTIC CABLE WITH 48V ENERGY FEEDER IN
2300 kg/km (1.55 LB/FT)APPROX. WEIGHT:
1.0 mMAXIMUM HANGER SPACING:
150 daNMAXIMUM PULLING STRENGTH:
360mm (14")MINIMUM BENDING RADIUS:
EUCAHYBRID 114-12AWG6MODEL:
EUPENMANUFACTURER:
ACABLE LENGTHS: *X110-L-SS-CDMA
T-503
ATYP. HYBRID COLOR CODE
6"10"-12"
6"6"6"10"-12"
6"6"6"6"6"10"-12"
FIRST HYBRID CABLE INSTALLED
STD72 TO VERIFY CURRENT COLOR CODING
REFER TO LATEST EDITION OF U.S. CELLULAR STANDARD:2.
MUST BE BANDED IN ACCORDANCE TO THE ILLUSTRATION ABOVE.
ENTRY POINT OF THE GROUND LEVEL JUNCTION BOX, HYBRID CABLES
AT THE TOP OF THE TOWER/BUILDING/WATER TOWER AND AT THE 1.
NOTES:
6" WIDE BROWN BAND (TYP.)
HYBRID CABLE (TYP.)
THIRD HYBRID CABLE INSTALLED (IF APPLICABLE)
SECOND HYBRID CABLE INSTALLED (IF APPLICABLE)
BTYP. COAX JUMPER BANDING
CTYP. POWER JUMPER BANDING
DTYP. RET CABLE BANDING
ETYP. BANDING CHART
SECTOR
(1) RED BANDALPHA
BETA
GAMMA
(IF APPLICABLE)
DELTA
(IF APPLICABLE)
EPSILON
(IF APPLICABLE)
ZETA
(2) RED BANDS
(1) WHITE BAND (2) WHITE BANDS
(1) BLUE BAND (2) BLUE BANDS
(1) GREEN BAND (2) GREEN BANDS
(1) VIOLET BAND (2) VIOLET BANDS
(1) BROWN BAND (2) BROWN BANDS
GSM
CDMA
LTE
BANDINGTECHNOLOGY
YELLOW
VIOLET
ORANGE
TECHNOLOGY BAND
700
1900
BANDINGFREQUENCY
GREEN
BROWN
FREQUENCY BAND
2100 WHITE
BLUE
10"-12" EMPTY SEE TYP. BANDING CHART
3/4" TO 1" FREQUENCY BAND;
10"-12" EMPTY
1" EMPTY (TYP.)
SEE TYP. BANDING CHART
3/4" TO 1" FREQUENCY BAND;
CA
BL
E B
AN
DIN
G D
ET
AIL
S
10"-12" EMPTY
1" EMPTY (TYP.)
B12
BAND
B5
B2
B4
2100 B66
VIOLET600 B71
3.5 GHz
GREY
RED-
COLOR
ASSIGNED
RED
WHITE
BLUE
GREEN
VIOLET
BROWN
LINE 1 LINE 2 LINE 3 LINE 4
(3) BROWN BANDS
(3) VIOLET BANDS
(3) GREEN BANDS
(3) BLUE BANDS
(3) WHITE BANDS
(3) RED BANDS
(4) BROWN BANDS
(4) VIOLET BANDS
(4) GREEN BANDS
(4) BLUE BANDS
(4) WHITE BANDS
(4) RED BANDS
SEE TYP. BANDING CHART
3/4" TO 1" SECTOR BANDS;
BETWEEN BANDS (TYP.)
1" SEPARATION
SEE TYP. BANDING CHART
3" TECHNOLOGY BAND;
SEE TYP. BANDING CHART
3/4" TO 1" SECTOR BANDS;
SEE TYP. BANDING CHART
3/4" TO 1" SECTOR BANDS;
SECTOR
(1) RED BANDALPHA
BETA
(2) RED BANDS
(1) WHITE BAND (2) WHITE BANDS
COLOR
ASSIGNED
RED
WHITE
LINE 1 LINE 2
RET SECTOR BAND
GAMMA (1) BLUE BAND (2) BLUE BANDSBLUE
SECTOR BAND (MOST COMMON CASE: SINGLE TECHNOLOGY WITHIN THE SECTOR)
SECTOR
(1) RED BANDALPHA (2) RED BANDS
COLOR
ASSIGNED
RED
SECTOR BAND (EXCEPTION CASE: ALPHA SECTOR CDMA ON 1 & 4, LTE ON 2 & 3)
LINE 1 (CDMA) LINE 2 (LTE) LINE 3 (LTE) LINE 4 (CDMA)
(2) RED BANDS(1) RED BAND
VERIFY CURRENT COLOR CODING
U.S. CELLULAR STANDARD: STD72 TO
REFER TO LATEST EDITION OF 1.
NOTE:
FTYP. COAX COLOR CODE STANDARD
ALPHA BETA GAMMA
LTE B5
L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4
ALPHA BETA GAMMA
L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4
ALPHA BETA GAMMA
LTE B4
L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4
ALPHA BETA GAMMA
LTE B2
L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4
ALPHA BETA GAMMA
L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4
ALPHA BETA GAMMA
L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4
ALPHA BETA GAMMA
L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4
ALPHA BETA GAMMA
L1 L2 L3 L4 L1 L2 L3 L4 L1 L2 L3 L4
LTE B12
LTE B66 LTE B71
LTE B3.5 LTE B71/B12800/850
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
T-5
03.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
A
B
A
B
C
VACANT VACANT
VACANTVACANT
VACANT VACANT
T-504
CA
BL
E R
OU
TIN
G
AEXISTING SHELTER COAX PORT (INTERIOR VIEW)
BEXISTING TOWER CABLE LAYOUT
NORTH
A A
AA
A A
B
B B
B
B B
(TYP. OF 6)
LTE COAX TO BE REMOVED
EXISTING U.S. CELLULAR
(TYP. OF 6)
CDMA COAX TO REMAIN
EXISTING U.S. CELLULAR
GPS CABLE TO REMAIN
EXISTING U.S. CELLULAR CDMA
9-HOLE
WATER TOWER LEG BRACKET
CPROPOSED SHELTER COAX PORT (INTERIOR VIEW)
DPROPOSED TOWER CABLE LAYOUT
NORTH
B
B B
B
B B
(TYP. OF 6)
CDMA COAX TO REMAIN
EXISTING U.S. CELLULAR
GPS CABLE TO REMAIN
EXISTING U.S. CELLULAR CDMA
9-HOLE
WATER TOWER LEG BRACKET
SITE PRO 1 #: SRZERO OR APPROVED EQUAL
AT PORTS OF DECOMMISSIONED LINES;
CONTRACTOR TO REPLACE CUSHION INSERTS
PROPOSED 1/2" GPS CABLE SITE PRO 1 #: SR114 OR APPROVED EQUAL
NEW CUSHION INSERT REQUIRED;
(TYP. OF 3);
PROPOSED 1-1/4" EUPEN HYBRID CABLE
C C C
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
T-5
04.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
A B C D
1
A B C D
E F G H
A B
E// B71/B12 / B2/B4 / 2T2R B5/B46
2 5 6 4387
+45 -45 -45+45 -45+45 -45+45
1 2 5 6 87
+45 -45 -45+45 -45+45 -45+45
#
#
#
R1: 617-906 Y1: 1695-2700 Y2: 1695-2700 R2: 617-906 R1: 617-906 Y1: 1695-2700 Y2: 1695-2700 R2: 617-906
43
T-505
PL
UM
BIN
G D
IAG
RA
M
CABLE LEGEND
ANTENNA UNIT
RADIO 1
ANT/PORT 4
ANT/PORT 3
ANT/PORT 2
ANT/PORT 1
+45°
4TH R/BRANCH
2ND R/BRANCH
3RD R/BRANCH
1ST R/BRANCH
-45°
CROSS POLE ANT. TO RADIO PORT DIAGRAM
PER SECTOR CONFIGURATION
CONFIDENTIAL INFORMATION. NOT FOR EXTERNAL USE OR DISCLOSURE WITHOUT PROPER AUTHORIZATION.®
CONTAINS U.S. CELLULAR
+45°
-45°
PCS ROW
AWS ROW
R/PORT D or H
R/PORT C of G
R/PORT B or F
R/PORT A or E
DATE CREATED: 05/13/2019
10 GB SFP
ERICSSON RRU2205 B46
5 GHz
LAA
CAP ON ALL UN-USED PORTS.
CONTRACTOR TO INSTALL WEATHERPROOF 2.
ANTENNAS MUST BE THE SAME LENGTH.
ALL JUMPERS BETWEEN RADIO UNITS & 1.
NOTES:
BOTTOM RAYCAP SPD
HYBRID CABLE TO
10 GB
10 GB
10 GB 10 GB
3 GB
RAYCAP SPD
POWER & FIBER
B71/B12 - B2/B4 - B5 - B46
4.3-10 CONNECTORS
1900/700/600 MHz
PCS/LTE
4.3-10 CONNECTORS
2100/850 MHz
AWS/LTE
3 GB SFP
7/16 DIN CONNECTORS
ERICSSON RRU11 B5
10 GB SFP
4.3-10 CONNECTORS
ERICSSON RRU8843 B2/B4
10 GB SFP
4.3-10 CONNECTORS
ERICSSON RRU4449 B71/B12
INSTALLED AT EACH ADDITIONAL SECTOR.
ADDITIONAL RAYCAPS/HYBRIDS TO BE
DEDICATED TO INDIVIDUAL SECTOR.
RAYCAP(S)/HYBRID(S) SHOWN ARE TO BE 3.
NOTE:
7/16 DIN CONNECTORS
CDMA EQUIPMENT
TO GROUND LEVEL WEATHERPROOF CAP
LOW BAND PORT
MID BAND PORT
RET JUMPER
POWER JUMPER
FIBER JUMPER
1/2" COAX JUMPER
CDMA COAX CABLE
EUPEN HYBRID CABLE
PLUMBING DIAGRAM: AX110-L-SS-CDMA
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
T-5
05.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
T-901
SIT
E P
HO
TO
S
A SHELTER COAX PORT (SHELTER INTERIOR) B C
FD
EXTERIOR SHELTER GROUND BAR
SEE T-504 FOR DETAILS
(3) PROPOSED U.S. CELLULAR CABLES;
SEE E-501 FOR DETAILS
CABLE GROUND LUGS;
(3) PROPOSED U.S. CELLULAR
SNAP-INS
ALONG ICE BRIDGE IN VACANT
PROPOSED CABLE ROUTE
SEE T-504 FOR DETAILS
(3) PROPOSED U.S. CELLULAR CABLES;
SEE T-504 FOR DETAILS
PROPOSED U.S. CELLULAR GPS CABLE;
COAX ICE BRIDGE
F CABLE ROUTING UP TOWER RESERVOIREXISTING U.S. CELLULAR COAX ROUTING UP TOWER LEG CABLE ROUTING UP TOWER LEG
SNAP-INS
ALONG ICE BRIDGE IN VACANT
PROPOSED CABLE ROUTE
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
1500\2
1514\C
AD
\Constr
ucti
on_D
raw
ings\P
lot\
T-9
01.d
gn
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
THIS S
PA
CE I
NTE
NTIO
NALLY L
EFT B
LA
NK
THIS S
PA
CE I
NTE
NTIO
NALLY L
EFT B
LA
NK
E-501
GR
OU
ND
ING
DE
TA
ILS
B
A SMOOTH DOWNWARD PATH (TYP.)
ROUTING TO GROUND BAR TO FOLLOW
ALL EQUIPMENT GROUND LEADS
UPPER EQUIPMENT GROUND BAR
SEE TABLE BELOW
GROUND BAR;
TIN PLATING SITE PRO 1 #: TIN21524 OR APPROVED EQUAL
SITE PRO 1 PART #: MG21524 OR APPROVED EQUAL
SIZED FOR 12 SETS OF 2-HOLE LUGS
1/4" x 2" x 15" GROUND BAR WITH INSULATORS AND BRACKETS
SITE PRO 1 PAR #: ADAP
ANGLE ADAPTER (TYP.);
STAINLESS STEEL
SPECIFICATIONS
RADIUS PER MANUFACTURER
MAINTAIN MINIMUM BEND
EQUIPMENT GROUND BAR
GROUND BAR SCHEDULE:
MECHANICAL CONNECTIONS
COMPOUND TO ALL
APPLY ANTI-OXIDANT
STATE, AND NATIONAL ELECTRIC CODE
POWER GROUND AND FOLLOW ALL LOCAL,
SYSTEM, IT MUST BE PROPERLY GROUNDED TO
TO TOWER, BY PIERCING TOWER COATING
NO EQUIPMENT OR CABLES MAY BE GROUNDED
DATE: DESCRIPTION:
SUBMITTAL:
INT.
SHEET
NUMBER
3/26/2021
I:\2
15
00
\21
51
4\C
AD
\Co
nstr
ucti
on
_D
raw
ing
s\P
lot\
E-5
01
.dg
n
AMF
BY
CHECKED
DATE
PLOT
NUMBER
PROJECT
TYPE
SET
CONSULTANT:
CLIENT:
www.edgeconsult.com
608.644.1549 FAX
608.644.1449 VOICE
PRAIRIE DU SAC, WI 53578
624 WATER STREET
REV. A
DRAFT
MIL
TO
N, W
ISC
ON
SIN
MIL
TO
N D
OW
NT
OW
N (
77
83
35
)
21514
10/1/2019
AMF 10/7/2019 REV. B
ADS 09/22/2020 REV. 0
TAS 03/26/2021 REV. 1
CHICAGO, IL 60631
SUITE 700
8410 W. BRYN MAWR AVE.
U.S. CELLULAR
KCB
SEE T-002 FOR DETAIL
REMOTE RADIO (TYP.);
SEE T-002 FOR DETAIL
RAYCAP SPD (TYP.);
SHELTER RAYCAP SPD
ROUTE TO
OR POWER CABLE (TYP.)
HYBRID (POWER/FIBER)
CABLE GROUND KIT
WEATHERPROOF
SEE DETAIL TO THE RIGHT
MOUNT TO TOWER STEEL (TYP.);
GROUND KITS AT ONE LEVEL
CONNECTION OF MULTIPLE
EQUIPMENT GROUND BAR FOR
ATYPICAL UPPER EQUIPMENT GROUNDING
LONG BARREL LUG (TYP.)
TO GROUND BAR WITH 2 HOLE
STRANDED CU WIRE CONNECTION
#6 AWG THHN GREEN INSULATED
RADIO GROUND KIT
LONG BARREL LUG (TYP.)
GROUND BAR WITH 2 HOLE
WIRE CONNECTION TO
INSULATED STRANDED CU
#6 AWG THHN GREEN
RAYCAP SPD GROUND KIT
2 HOLE LONG BARREL LUG (TYP.)
CU WIRE CONNECTION TO GROUND BAR WITH
#6 AWG THHN GREEN INSULATED STRANDED
HYBRID CABLE OR POWER CABLE GROUND KIT
TOWER GROUND BAR
EXISTING LOWER
MECHANICAL CONNECTIONS
COMPOUND TO ALL
APPLY ANTI-OXIDANT
ICE BRIDGE
ROUTE ALONG
SHELTER RAYCAP SPD
ROUTE TO
UPPER RAYCAP SPD
ROUTE TO
DLOWER EQUIPMENT GROUNDING
GROUND KIT (TYP.)
WEATHERPROOF CABLE
GROUND BAR
EXISTING SHELTER
OR POWER CABLE
HYBRID (POWER/FIBER)
2 HOLE LONG BARREL LUG (TYP.)
CU WIRE CONNECTION TO GROUND BAR WITH
#6 AWG THHN GREEN INSULATED STRANDED
HYBRID CABLE OR POWER CABLE GROUND KIT
GPS ANTENNA
ICE BRIDGE POST
WITH PIPE TO PIPE CLAMP SET
SECURE TO ICE BRIDGE POST
GPS ANTENNA MOUNTING PIPE;
OR APPROVED EQUAL
HARGER PART #: UPC2.5/3
UNIVERSAL GROUNDING CLAMP;
OR APPROVED EQUAL
HARGER PART # UPC.75/1.25
UNIVERSAL GROUNDING CLAMP;
MOUNT TO ICE BRIDGE POST
GROUND LEAD FROM GPS PIPE
#2 STRANDED INSULATED COPPER
CGPS GROUNDING