Post on 03-Dec-2014
Jakarta, 25 November 2011 Oleh :
Asep MuhidinSely Prima Gustian
Yogo Triyanto
SKEMATIK JALUR LISTRIK CWJ20 kV
LINE 1
LINE 2
LINE 3
LINE
SKEMATIK JALUR LISTRIK CWJ20 kV
LINE
LINE 3
LINE 5
LINE 4PLN (GI/GIS)
ABDI GUNA PAPAN
SKEMATIK JALUR LISTRIK CWJ20 kV
PLN ROOM
CWJ di B1
LINE 2
LINE 3
LINE 5
LINE 4PLN (GI/GIS)
ABDI GUNA PAPAN
SKEMATIK JALUR LISTRIK CWJ20 kV
PLN ROOM
CWJ di B1
OFFICE
LINE 1
LINE 2
LINE 3
LINE 5
LINE 4PLN (GI/GIS)
ABDI GUNA PAPAN
SKEMATIK JALUR LISTRIK CWJ20 kV
PLN ROOM
CWJ di B1
OFFICE
PODIUM
LINE 1
LINE 2
LINE 3
LINE 5
LINE 4PLN (GI/GIS)
ABDI GUNA PAPAN
SKEMATIK JALUR LISTRIK CWJ20 kV
PLN ROOM
CWJ di B1
OFFICE
PODIUM
LINE 1
LINE 2
LINE 3
LINE 5
LINE 4PLN (GI/GIS)
ABDI GUNA PAPAN
SKEMATIK JALUR LISTRIK CWJ20 kV
PLN ROOM
CWJ di B1
OFFICE
PODIUM
LINE 1
LINE 2
LINE 3
LINE 5
LINE 4PLN (GI/GIS)
ABDI GUNA PAPAN
SKEMATIK JALUR LISTRIK CWJ20 kV
PLN ROOM
CWJ di B1
OFFICE
PODIUM
APARTMENT
&
HOTEL
LINE 1
LINE 2
LINE 3
LINE 5
LINE 4PLN (GI/GIS)
ABDI GUNA PAPAN
SCHEMATIC ELECTRICA
L SYSTEM
Skematik
PLN ROOM
Skematik
PANEL MVMSB
PLN ROOM
Skematik
PANEL MVMSB
GENSET
PLN ROOM
Skematik
PANEL MVMSB
TRAFO STEP UPGENSET
PLN ROOM
Skematik
PANEL MVMSB
TRAFO STEP UPGENSET
PLN ROOM
Skematik
CHILLER
PANEL MVMSB
TRAFO STEP UPGENSET
PLN ROOM
Skematik
CHILLER
PANEL MVMSB
TRAFO STEP UPGENSET
TRAFO STEP DOWN
PLN ROOM
Skematik
CHILLER
PANEL MVMSB
TRAFO STEP UPGENSET
TRAFO STEP DOWN PANEL LVMSB
PLN ROOM
Skematik
CHILLER
PANEL MVMSB
TRAFO STEP UPGENSET
TRAFO STEP DOWN PANEL LVMSB
PLN ROOM
HDB
Skematik
CHILLER
PANEL MVMSB
TRAFO STEP UPGENSET
TRAFO STEP DOWN PANEL LVMSB
PLN ROOM
ZDB
HDB
Skematik
CHILLER
PANEL MVMSB
TRAFO STEP UPGENSET
TRAFO STEP DOWN PANEL LVMSB
PLN ROOM
MCC
ZDB
HDB
Skematik
CHILLER
PANEL MVMSB
TRAFO STEP UPGENSET
TRAFO STEP DOWN PANEL LVMSB
PLN ROOM
MCC
ELEVATOR
ZDB
HDB
DB
Skematik
CHILLER
PANEL MVMSB
TRAFO STEP UPGENSET
TRAFO STEP DOWN PANEL LVMSB
PLN ROOM
MCC
ESCALATOR ELEVATOR
ZDB
HDB
DB
DB
Jenis penghantar
Jenis penghantar1. Kabel Kabel LV/TR Kabel MV/TM
Jenis penghantar
2. BUS DUCT (SCHENEIDER) Busduct dari Trafo ke Panel LVMSB ( Scheneider) Busduct dari Genset ke panel sinkron lanjut ke trafo Step Up (By
BME)
Jenis penghantar1. Kabel Kabel LV/TR Kabel MV/TM
2. BUS DUCT (SCHENEIDER) Busduct dari Trafo ke Panel LVMSB ( Scheneider) Busduct dari Genset ke panel sinkron lanjut ke trafo Step Up (By
BME)
DAYA DARI PLN
TAHAP I : 16.180kVA, bulan Maret 2012
DAYA DARI PLN
TAHAP I : 16.180kVA, bulan Maret 2012TAHAP II : 13.160 Kva, bulan Agustus 2012
DAYA DARI PLN
TAHAP I : 16.180 kva, bulan Maret 2012TAHAP II : 13.160 kva, bulan Agustus 2012
TOTAL 30 MVASumber : Minutes meeting 15 Juli 2011
Data Backup Genset terpasang di tiap tower
Item Office Podium Hotel Apartemen
Genset 2 x 2 MVA
(Lantai 11)
9 X 2 MVA
(B2)
3 X 2 MVA
(Lantai 13)
2 X 1.25MVA
(Lantai 9)
KEBUTUHAN DAYA TIAP TOWER SESUAI DAYA
AKTIF TRAFO
KEBUTUHAN DAYA TIAP TOWER SESUAI DAYA AKTIF TRAFO
PEKERJAAN ELEKTRIKALYANG SUDAH BERJALAN
di Ciputra World Jakarta
Lightning Arester
Cabel Tray dan Conduit
CONDUITCABEL TRAY