FEASIBILITY REPORT FOR RESIDUE UPGRADATION PROJECT AT
MUMBAI REFINERY UNDER MREP PHASE II
HINDUSTAN PETROLEUM CORPORATION LIMITED, MUMBAI REFINERY
Document No. A965-79-41-000-RP-003
Page 2of 11
Feasibility Report for Residue Upgradation Project,
HPCL Mumbai Refinery
1.0 INTRODUCTION
HPCL’s Mumbai Refinery was established in 1954. Through progressive revamps/ capacity expansions, current crude oil processing capacity of HPCL-MR is 7.5 MMTPA. It currently has two trains of primary distillation units (FR APS/VPS and FRE APS/VPS, associated secondary processing facilities viz. Old & New FCCUs, DHDS & DHDT, MS Block (NHT/ISOM, NHT/CCR and Prime-G+), LOBS production facilities and other associated treating & utility facilities. The refinery has also revamped its DHDS unit through Isotherming technology licensed by DuPont to produce ultra-low sulfur Diesel. With the installed facilities, the refinery shall be able to produce Gasoline and Diesel meeting Euro IV quality specifications, besides other petroleum products like LPG, Naphtha, Kerosene, ATF, Fuel oil& Sulphur.
In view of the expected growth in demand for petroleum products, to meet the BS VI Auto Fuel Specifications for MS & HSD and to remain competitive in the market with product self-sufficiency, HPCL has planned to undertake the Mumbai Refinery Expansion Project (MREP) in two phases (Phase I and II) primarily to meet the following overall objectives:
Maximization of crude refining capacity (from existing 7.5 MMTPA to 9.5 MMTPA) for optimum capacity utilization of secondary processing facilities existing at Mumbai Refinery.
Meeting BS – V/VI specifications for MS and HSD.
Improvement in GRM by maximization of distillate yields using Hydrogen Based Bottoms Upgradation facilities.
Zero Fuel Oil and zero Export Naphtha production. Mumbai Refinery has already undertaken implementation of Phase I of the project after obtaining Environmental Clearance, and the following facilities are expected to be installed post Phase I:
1. MR capacity expansion (FR crude unit revamp) from existing 7.5 MMTPA to 9.5 MMTPA
2. Revamp of MS block and DHDT units to produce BS-VI MS and HSD
NHT/ISOM revamp by 30%
NHT/CCR revamp by 35 %
Prime G+ revamp by 30%
Document No. A965-79-41-000-RP-003
Page 3of 11
Feasibility Report for Residue Upgradation Project,
HPCL Mumbai Refinery
Revamp of DHDT for VGO and diesel co-processing mode
3. MR II tankage facilities at Calico land for construction of a new tank farm
4. New HGU of capacity 65 KTPA
For Phase –II, HPCL intends to carry out Detailed Feasibility Report (DFR) for
Hydrogen Based Residue Up-gradation project primarily to meet the following
objectives:
To improve refinery profitability (GRM) by maximizing distillate yields using Hydrogen Based Bottoms Upgradation facilities.
To saturate the existing secondary processing units, mainly FCCUs and DHDS/DHT units, as also for targeting zero fuel oil and zero export naphtha production
HPCL has entrusted EIL to carry out the job of preparation of detailed feasibility
report (DFR) for Phase II expansion of Mumbai Refinery Expansion Project
(MREP), which includes:
Configuration study for a refinery throughput of 9.5 MMTPA with a new hydrogen based residue up-gradation facility
Matching treating and utility & offsite (U&O) facilities for the selected crude mix.
Base Case for Phase II Refinery Configuration study will be the refinery configuration established under Phase I DFR.
In order to estimate the capital investment within accuracy of ± 20% and to
establish the implementation plan for Phase II Residue upgradation project,
refinery configuration study & preparation of DFR are performed based on in-
house process knowledge, state-of the art tools and years of expertise with EIL.
2.0 DETAILED FEASIBILITY REPORT
Base case
The Base case was developed by LP modeling, considering the following:
Crude Mix:
Crude thru’put of 9.5 MMTPA is considered with the following crude mix:
Bombay High: 3.5 MMTPA
Arab Light: 2 MMTPA
Basrah Crude: 4 MMTPA
Document No. A965-79-41-000-RP-003
Page 4of 11
Feasibility Report for Residue Upgradation Project,
HPCL Mumbai Refinery
(FR=4MMTPA Basrah + 2 MMTPA AL; FRE=3.5 MMTPA BH)
Feed/ product prices:
Three years’ average price taken from 2015-2018
Key considerations:
1. Revamp of FRAPS unit upto crude processing capacity of 6 MMTPA and a new VPS unit (VDU) has been installed for processing the RCO generated from revamped FRAPS.
2. Revamp of MS block units (NHT/CCR by 35%, NHT/ISOM by 30% and Prime G+ by 30%) is completed.
3. Revamp of DHDT for co-processing of diesel and VGO and subsequent routing of hydrotreated VGO to Old FCCU is completed.
4. A new HGU, for supplying hydrogen to refinery is installed.
5. SOX limit for the refinery shall be a maximum of 12.6 TPD.
6. CPP revamp has not been considered under this DFR.
7. Minor modification, if required, may be undertaken in GFEC SWS and DHT ARU to process the increased sour water and rich amine generated post Phase I expansion.
Phase II Expansion case
The final Phase II expansion case was developed by LP modelling, considering
the following:
Crude Mix:
Design Crude Mix 1
Bombay High: 3.5 MMTPA
Arab Light: 2 MMTPA
Kuwait Crude: 4 MMTPA
(FR=4MMTPA Kuwait + 2 MMTPA AL; FRE=3.5 MMTPA BH)
Design Crude Mix 2
Bombay High: 3.5 MMTPA
Kuwait Crude: 6 MMTPA
(FR=6MMTPA Kuwait; FRE=3.5 MMTPA BH)
Document No. A965-79-41-000-RP-003
Page 5of 11
Feasibility Report for Residue Upgradation Project,
HPCL Mumbai Refinery
Design Crude Mix 3
Bombay High: 3.5 MMTPA
Basrah Crude: 6 MMTPA
(FR=6MMTPA Basrah; FRE=3.5 MMTPA BH)
Feed/ product prices:
Three years’ average price taken from 2015-2018
Objectives:
Residue Up-gradation. Maximization of distillates. Zero Fuel Oil and zero Export Naphtha production.
Material balance
Out of all the LP cases developed, only one have been shortlisted based on
the preliminary economic analysis and other factors such as plot
requirement, reliability, proven track record etc.
The shortlisted case is as follows:
Crude mix: 6 MMTPA Basrah + 3.5 MMTPA Bombay High, with RUF-Ebullated bed technology.
Basrah crude was selected over Kuwait crude due to its ease of
availability and low purchase cost giving a higher GRM.
Basrah crude was selected over Arab Light as the VR yield of Basrah is
higher and thus maximizing the Residue upgradation capacity.
Elaborate explanation on selection of Ebullated bed technology over the
others residue upgradation technologies is provided in the DFR.
Material balance for the base case and Phase II shortlisted case are
provided in the table below.
Overall Material Balance of Refinery
Stream
Base Case
(LP Case no.141)
Expansion Case
(LP Case no.244)
FEED (000’TPA)
Bombay High 3500 3500
Basrah 4000 6000
Arab Light 2000 -
Total crude 9500 9500
Document No. A965-79-41-000-RP-003
Page 6of 11
Feasibility Report for Residue Upgradation Project,
HPCL Mumbai Refinery
Natural Gas 24 24
Additive - 1.3
Import VR - 606
Total feed 9524 10131
PRODUCT(000’TPA)
LPG 535 638
LAN 103 -
SCN 96 96
Treated Hexane 30 30
Solvent1425 8.5 8.5
MS BS VI 1731 1830
Total MS 1731 1830
MTO 48 48
ATF 600 600
SKO 52.2 52.2
Diesel BS VI 3406 4614
Total Diesel 3406 4614
LDO - -
RPO - -
FO180cst 1015 -
FO Bunker - -
Total Fuel oil 1015 -
Sulphur 63 189
150 N Gr-I 70 70
500 N Gr-I 100 100
Spindle Oil –Gr-I 15 15
Spindle Oil –Gr-II 32 32
150 N Gr-II 76 76
500 N Gr-II 92 92
Bright Stock 50 50
IO-100 15 15
Total LOBS 450 450
VG-10 Bitumen 234 -
VG-30 Bitumen 546 252
VG-40 Bitumen - 377
Total Bitumen 780 629
Slurry Pitch - 127
Fuel& Loss 606 820
Total 9524 10131
Document No. A965-79-41-000-RP-003
Page 7of 11
Feasibility Report for Residue Upgradation Project,
HPCL Mumbai Refinery
3.0 PROCESS UNITS
The design capacities of new process units envisaged under MREP Phase
II is provided in the table below:
Design Capacities of new Process Units
A.
New Processing Unit
Capacity
1 RESIDUE UPGRADATION FACILITY (RUF) MMTPA 1.81
B. New Auxiliary Units
1 HYDROGEN GENERATION UNIT (HGU) KTPA 65
2 SOUR WATER STRIPPERUNIT (SWS) TPH 66
3 AMINE REGENERATION UNIT (ARU) TPH 310
4
SULPHUR RECOVERY UNIT (SRU) WITH TAIL GAS
TREATING UNIT (TGTU) TPD 2X 180
4.0 NEW UTILITY SYSTEMS
The utility facilities for the Refinery consist of the following:
Cooling water system
DM water system
Compressed air system
Nitrogen system
Steam, power and BFW system
Condensate system
Internal fuel oil and fuel gas system
Bearing Cooling Water System.
Flare system.
The existing utility systems will be completely saturated post Phase I expansion
of the refinery. Hence, to meet the Phase II utility demand, new utility systems
have been configured.
The utility requirement for the Phase II various units and utility & offsite have
been referred from EIL in house data. Based on this the Utility block
configuration have been worked out. Present DFR costing have been carried
out considering this utility block configuration.
However, utility summary and the utility block configuration shall be finalized at
design stage after finalization of licensors of new process units.
Following New Utility Systems shall come up in MREP Phase-II expansion:
Document No. A965-79-41-000-RP-003
Page 8of 11
Feasibility Report for Residue Upgradation Project,
HPCL Mumbai Refinery
New Utility Systems
NEW UTILITY SYSTEM DETAILS OF FACILITIES
Bearing Cooling Water System
Bearing Cooling Tower Cells 2 number of cells(1 working+1 standby),
each having a capacity of 700 m3/hr.,
Type: Induced draft
Bearing cooling water circulation
pumps
Number: 2 (1 working + 1 standby)
Capacity: 700 m3/hr. per pump
Head: 60 m
Type: Horizontal centrifugal
Drive: Electric motor
Side stream filters 2 number , each of capacity 14 m3/hr.
Compressed Air System (Plant and Instrument Air)
LP air Compressor
Number: 2 (1 working + 1 standby)
Capacity: 20000 Nm3/hr. each
Type: Centrifugal, non-lubricated
Drive: Electric motor
HP air Compressor
Number 1 (1 working + 0 standby) Capacity: 250 Nm3/hr. each Type: Reciprocating Drive: Electric Motor
Instrument air Dryer
Number: 2 (1 working + 1 standby)
Capacity: 10000 Nm3/hr.
Type: No loss purge, split flow, closed circuit,
heat of compression type)
Dual bed absorption with activated alumina as
desiccant
Nitrogen System-taken care in Phase I N2 plant
Steam and Power system
Utility Boiler
Number: 1 (1 standby) Capacity: 125 TPH of gross HP steam (i.e. 100 TPH of net HP steam) generation at 40 kg/cm2g
Steam Turbine Generator Number: 1
Rating: 10 MW power generation
Type: Extraction
Sea cooling water system
Sea cooling tower Number: 3 (2 working + 1 standby)
Capacity: 4000 m3/hr. each
Sea cooling water recirculation
pump
Number = 2 working + 1 standby Capacity: 4000 m3/hr. each Pump Head: 60 m
Document No. A965-79-41-000-RP-003
Page 9of 11
Feasibility Report for Residue Upgradation Project,
HPCL Mumbai Refinery
NEW UTILITY SYSTEM DETAILS OF FACILITIES
Side stream filter Number: 2 Capacity: 80 m3/hr. each
DM water system
DM water chain Number: 2 (1 working + 1 standby) Capacity: 220 TPH each
Raw water system
Raw water sump Dimension: 25m X 25m X 5m:
Raw water pump to DM feed Number- (2working +1 standby) Capacity:100m3/hr.each
Raw water pump to BCT Number- (1 working + 1 standby)
Capacity: 40 m3/hr each
Raw water pump as service
water
Number- (1 working + 1 standby) Capacity: 50 m3/hr each
Flare system
HC flare Flare stack: Dia: 72" , Height: 110 m, MOC: KCS
+ 3mm CA+PWHT
Flare KOD: Dia: 6 m, TL/TL-27 m, MOC: KCS +
3mm CA + PWHT
Water seal drum: Dia: 5.5 m, TL/TL: 9 m, MOC:
KCS with cement lining internals: SS316L.
Flare tip: Dia: 72 ", MOC: Incoloy 825.
Sour flare Flare stack: Dia: 20" , Height: 110 m, MOC: KCS
+ 3mm CA+PWHT
Flare KOD: Dia: 2 m, TL/TL-6 m, MOC: KCS +
3mm CA + PWHT+HIC
Flare tip: Dia: 20 ", MOC: Incoloy 625.
5.0 NEW OFFSITE FACILITIES
The offsite facilities shall be augmented by adding following new storage
facilities under MREP Phase-II.
List of new offsite tanks
Sl.
No. Service
Gross
Capacity
per Tank,
M3
Height/
Length, m
Diameter
, m
No of
Tanks Type
1 LPG 2080 50.0 7.00 3.0 Mounded Bullet
2 HGU feed 5034 15.0 21.00 1.0 External Floating Roof
Document No. A965-79-41-000-RP-003
Page 10of 11
Feasibility Report for Residue Upgradation Project,
HPCL Mumbai Refinery
3 VR 14605 20.0 30.50 3.0 Cone roof
Apart from these tanks, 4 Naphtha tanks will be reassigned / realigned to
cater to the space requirement of this project.
In addition to the above, the following are the new offsite pumps envisaged
in MREP Phase II:
List of new offsite pumps
Sl.
No. Service
Each
Pump flow
(m3/hr)
Head
(m)
No. of
pumps Type
1 VR pump from MR-II area to RUF* 182 119 1+1 Screw Pump
2 VR pump from VPS to MR-II area# 235 60 1+1 Screw Pump
3 HCGO pump from MR-II area to RUF* 35 95 1+1 Centrifugal
4 HCGO pump from NFCC to MR-II/RUF area* 45.0 57 1+1 Centrifugal
5 ASPHALT pump from MR-II area to RUF* 40.0 113 1+1 Screw Pump
6 HGU feed pump* 57 89 1+1 Centrifugal
7 VR pump from FRE-VPS to RUF/MR-II# 43 75 1+1 Screw Pump
Note: All pumps are motor driven, MOC: CS.
* New pumps
# Existing pumps. Adequacy to be checked during detail engineering. For
DFR costing, cost of news pumps have been considered.
6.0 ENVIRONMENTAL EMISSIONS
The stipulated SOx emission limit is 12.6 TPD for HPCL Mumbai Refinery. For
the enhanced capacity of 9.5MMTPA and with Residue Upgradation Facility,
SOX emissions are estimated to remain within the maximum limits. This is
possible as a result of various measures taken-up during the configuration
study of the project, such as improved furnace efficiency, use of only low
Sulphur fuel oil (Sulphur content 0.5 wt.%) in furnaces and also due to high
Sulphur recovery in the existing two SRUs and new SRU envisaged under this
project. Also, low NOx burners will be installed to reduce NOx emission from all
furnaces. The estimated SOx emission from the refinery post Phase II
expansion is within the stipulated limit.
Document No. A965-79-41-000-RP-003
Page 11of 11
Feasibility Report for Residue Upgradation Project,
HPCL Mumbai Refinery
7.0 RECOMMENDATION
Based on the detailed feasibility study it is recommended to consider a Hydrogen based Residue Upgradation Facility as part of MREP Phase II Project. The Phase II project includes the new facilities as follows:
Residue Upgradation Unit– Ebullated bed Hydrocracking Technology.
Hydrogen Generation Unit
Sulfur Block
Matching Treating Units
Matching Utility and Offsite facilities.
The total estimated capital cost for the Phase II Expansion case is ₹ 6963 crores.