SINGLY REINFORCED BEAM - DPG Polytechnic

31
SINGLY REINFORCED BEAM By limit state method of design

Transcript of SINGLY REINFORCED BEAM - DPG Polytechnic

SINGLY REINFORCED BEAM By limit state method of design

DIFFERENT METHODS OF DESIGN

OF CONCRETE

1. Working Stress Method

2. Limit State Method

3. Ultimate Load Method

4. Probabilistic Method of Design

LIMIT STATE METHOD OF DESIGN

The object of the design based on the limit state concept is to achieve an acceptable probability, that a structure will not become unsuitable in it’s lifetime for the use for which it is intended,

i.e. It will not reach a limit state

A structure with appropriate degree of reliability

should be able to withstand safely.

All loads, that are reliable to act on it throughout it’s

life and it should also satisfy the subs ability requirements, such as limitations on deflection and cracking.

It should also be able to maintain the required

structural integrity, during and after accident, such as

fires, explosion & local failure.

i.e. limit sate must be consider in design to ensure

an adequate degree of safety and serviceability

The most important of these limit states, which must

be examine in design are as follows

Limit state of collapse

- Flexure

- Compression

- Shear

- Torsion

This state corresponds to the maximum load carrying

capacity.

TYPES OF REINFORCED CONCRETE

BEAMS

b) Singly reinforced beam

c) Doubly reinforced beam

d) Singly or Doubly reinforced flanged

beams

SINGLY REINFORCED BEAM

In singly reinforced simply supported beams

or slabs reinforcing steel bars are placed

near the bottom of the beam or slabs where

they are most effective in resisting the

tensile stresses.

Reinforcement in simply supported beam

COMPRESSION b

d

SECTION A - A

CLEAR SPAN

D

STEEL REINFORCEMENT

TENSION

SUPPORT

Reinforcement in a cantilever beam

SECTION A - A

A

TENSION

D

COMPRESSION

A

CLEAR COVER

d

STRESS – STRAIN CURVE FOR CONCRETE

fck

STRESS

.20 % .35%

STRAIN

STRESS ― STARIN CURVE FOR STEEL

STRESS BLOCK PARAMETERS

!

0.0035 0.446 fck

X2 X2

X1 X1

a

The depth of neutral axis can be obtained by

considering the equilibrium of the normal forces ,

that is, Resultant force of compression = average stress X area

= 0.36 fck bx

Resultant force of tension = 0.87 fy At

Force of compression should be equal to force of tension,

0.36 fck bx = 0.87 fy At

x =

Where At = area of tension steel

x = Depth of Neutral axis

b = breadth of section

d = effective depth of section

Moment of resistance with respect to concrete = compressive force x lever arm

= 0.36 fck b x z

Moment of resistance with respect to steel = tensile force x lever arm

= 0.87 fy At z

MAXIMUM DEPTH OF NEUTRAL

AXIS

A compression failure is brittle failure.

The maximum depth of neutral axis is limited to ensure that tensile

steel will reach its yield stress before concrete fails in compression,

thus a brittle failure is avoided.

The limiting values of the depth of neutral axis xm for different grades

of steel from strain diagram.

MAXIMUM DEPTH OF NEUTRAL

AXIS

fy N/mm2 xm

250 0.53 d

415 0.48 d

500 0.46 d

LIMITING VALUE OF TENSION

STEEL AND MOMENT OF

RESISTANCE

Since the maximum depth of neutral axis is limited, the maximum value of moment of resistance is also

limited.

Mlim with respect to concrete = 0.36 fck b x z

= 0.36 fck b xm (d – 0.42 xm)

Mlim with respect to steel = 0.87 fck At (d – 0.42 xm)

LIMITING MOMENT OF RESISTANCE

VALUES, N MM

Grade of

concrete

Grade of steel

Fe 250 steel Fe 450 steel Fe 500 steel

General 0.148 fck bd 0.138 fck bd 0.133 fck bd

M20 2.96 bd 2.76 bd 2.66 bd

M25 3.70 bd 3.45 bd 3.33 bd

M30 4.44 bd 4.14 bd 3.99 bd

TYPES OF PROBLEM

b) Analysis of a section

d) Design of a section

a) For under reinforced section, the value of x/d is less than xm/d value.

The moment of resistance is calculated by following equation:

Mu = 0.87 fy At d –

g) For balanced section, the moment of resistance is calculated by the

following equation:

Mu = 0.87 fy At ( d – 0.42xm)

k) For over reinforced section, the value of x/D is limited to xm/d and the

moment of resistance is computed based on concrete:

Mu = 0.36 fck b xm ( d – 0.42 xm )

Analysis of section

Determine the moment of resistance for the section shown in figure.

(i) fck = 20 N/mm , fy = 415 N/mm

Solution:

(i) fck = 20 N/mm , fy = 415 N/mm

breadth (b) = 250 mm

effective depth (d) = 310 mm

effective cover = 40 mm

Force of compression = 0.36 fck b x

= 0.36 X 20 X 250x

= 1800x N

fy xm

415 0.48d

500 0.46d

Area of tension steel At

Force of Tension

=

=

3 X 113 mm

0.87 fy At

= 0.87 X 415 X 3 X 113

= 122400 N

Force of Tension = Force of compression

122400 = 1800x

x = 68 mm

xm = 0.48d

= 0.48 X 310

= 148.8 mm

148.8 mm > 68 mm

Therefore,

Depth of neutral axis

=

68 mm

Lever arm z = d – 0.42x

= 310 – 0.42 X 68

= 281 mm

As x < xm ( It is under reinforced )

o

o Since this is an under reinforced section, moment of resistance is

governed by steel.

o Moment of resistance w.r.t steel = tensile force X z

o Mu = 0.87fy At z

o = 0.87 X 415 X 3 X 113 X 281

o Mu = 34.40kNm

Design of a section

Question : Design a rectangular beam to resist a bending moment equal to 45 kNm

using (i) M15 mix and mild steel

Solution :

The beam will be designed so that under the applied moment both

materials reach their maximum stresses.

Assume ratio of overall depth to breadth of the beam equal to 2.

Breadth of the beam = b

Overall depth of beam = D

therefore , D/b = 2

For a balanced design,

Factored BM = moment of resistance with respect to concrete

= moment of resistance with respect to steel

= load factor X B.M

= 1.5 X 45

= 67.5 kNm

For balanced section,

Moment of resistance Mu = 0.36 fck b xm(d - 0.42 xm)

Grade for mild steel is Fe250

For Fe250 steel,

xm = 0.53d

Mu = 0.36 fck b (0.53 d) (1 – 0.42 X 0.53) d

= 2.22bd

Since D/b =2 or, d/b = 2 or, b=d/2

Mu = 1.11 d

Mu = 67.5 X 10 Nmm

d=394 mm and b= 200mm

fy xm

250 0.53d

415 0.48d

Area of tensile steel At =

=

= 962 mm

= 9.62 cm

Minimum area of steel Ao= 0.85

Adopt D = 450 mm

b = 250 mm

d = 415mm

=

= 353 mm

353 mm < 962 mm

In beams the diameter of main reinforced bars is usually selected

between 12 mm and 25 mm.

Provide 2-20mm and 1-22mm bars giving total area

= 6.28 + 3.80

= 10.08 cm > 9.62 cm

!