Page No. Effective From Valid Till Master List No. Version No ...

117
Page No. Effective From Valid Till Master List No. Version No. Page 1 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Transcript of Page No. Effective From Valid Till Master List No. Version No ...

Page No. Effective From Valid Till Master List No. Version No.

Page 1 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Page No. Effective From Valid Till Master List No. Version No.

Page 2 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

PREFACE

1. The “list of RDSO vendors for development orders” for manufacture and supply of items/ equipment of Electric Locomotives, EMU, TL&AC (for coaches), & equipment conductors for 25 kV AC Traction Installations and Energy Management approved by RDSO is updated upto one day prior to ‘Effective from’ date. The items are grouped Directorate-wise. The specification/ drawing/STR number of each of the item has been given in column No. 3.

2. “List of RDSO vendors for development orders” is being issued in accordance to Railway Board’s directives issued vide their letters No. 2001/RS(G)/779/7 dated 14.03.2017 and No. 2001/RS(G)/779/7 dated 01.02.2017.

3. The “list of RDSO vendors for development orders” is divided in five parts and consists of XII chapters in all. Part A contains items/equipment pertaining to Electric Loco. Part B contains items/equipment pertaining to EMU and TL & AC (coaches). Part C contains items pertaining to equipment and conductors for 25 kV AC Traction Installation. Part D contains items/equipments pertaining to Electric Loco, EMU and TL & AC (for coaches) and equipment & conductors for 25 kV AC Traction Installation dealt by Quality Assurance (Electrical) Directorate. Part E contains items/equipment pertaining to Energy Management. Region-wise Vendor’s name and addresses in full, their telephone, Fax numbers & Email addresses have been given at the end of each Part in Chapters II, V, VIII and X respectively, Standard mailing list is given in Chapter XII.

4. Items pertaining to Electric Loco and PS & EMU are appearing in the “list of RDSO vendors for development orders”, in compliance of Railway Board’s directives issued vide letters no. 2001/RS(G)/779/7 dated 07.12.2016 & 2001/RS(G)/779/7 dated 01.02.2017 respectively.

5. The policy to be followed in respect of procurement of OHE and PSI items has been clarified in Railway Board’s letter No. 2001/RE/161/12 dated 31.10.2001 and 2010/Elect (Dev) 225/1 dated 07.06.2010.

6. Sources for Energy Management are being developed in line with instructions issued by Railway Board vide their letter No. 2006/Elect(G)/150/9/Pt.I, dated 03.12.2015.

7. Traction Installation items of 2x25 kV AT system and conventional 25 kV BT system having common specification are given in Chapter I. However, the items exclusive to 2x25 kV AT systems are given in Chapter – VII.

8. Chapter VI and VII for Traction Installation items does not include the approved suppliers for parts, fittings and accessories for power transformer and interlocks for circuit breaker, interrupters and isolators. These equipments/ accessories are normally required by the manufacturers of power transformers, circuit breakers, interrupters and isolators. Suppliers for these equipments/accessories will be recommended by RDSO in the specifications of respective equipment.

9. The directorate-wise total no. of item- groups and total no. of items appearing in this List of Approved Vendors are as follows:

S.N. Directorate No. of item-groups

No. of items

1 Electrical Directorate 10 23

2 PS&EMU directorate 12 33

Page No. Effective From Valid Till Master List No. Version No.

Page 3 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

3 Traction Installation Directorate

18 98

4 QA (Electrical) Directorate

09 31

5 Energy Management 02 02

Total 51 187

10. To facilitate the procuring agency in nominating the inspecting agency, a region-wise list of vendors is given. The region-wise list is only for guidance of procuring agencies and is in no way meant to restrict the choice of vendors during tendering by Railways, on regional basis.

11. “Annual Production Capacity” (wherever furnished by firm) given in figures in column No. 5 against vendor, are committed to Railways by the firms. The annual production capacities of the vendors have been indicated in the List of Approved Vendors to the extent available. These figures are dynamic and may change from time to time, as the vendors keep on making adjustments in their product-wise capacity. These capacity figures are based on declarations of the vendors only and, in many cases, yet to be verified by RDSO. The production capacity figures indicated in this List of Approved Vendors are only indicative and in no way meant to influence the decisions of the Tender Committees while deciding the tenders.

12. Vendor’s Responsibility: If due to any oversight/ typographical error or any other reason, a vendor has been incorrectly placed in List of Approved for a particular item, then:

the vendor shall immediately inform RDSO in writing about the error (as per

latest version of ISO Doc. No. QO-D-7.1-9).

13. The Indian Firm/ Partner/ Representative, if any, should be treated as sales Representative of OEM subject to having valid MOU or Agreement with OEM. The validity of MOU/ Agreement should be verified by RDSO from the OEM at the time of granting approval. Railways while placing order should re-verify the validity of MOU/ Agreement with OEM.

14. Changes in list of RDSO vendors for development orders: Approvals granted in the intervening period between the issue of this directory and the next List of Approved Vendors to be issued should be considered as valid on the basis of the approval letters issued by Competent Authority of RDSO. Such changes in the list of RDSO vendors for development orders (e.g. addition/ deletion, etc.) would be made available through amendments. The list of RDSO vendors for development orders and its subsequent amendments shall be available at the RDSO web-portal www.rdso.indianrailways.gov.in accessible through the Internet.

15. Whenever inspection of item(s), for which a vendor is approved, is withheld/ suspended, the status of the firm shall remain unchanged i.e. for all purposes, the approval status of the vendor shall be as indicated in the list of RDSO vendors for development orders.

16. Procedure to be followed if samples are picked up from consignee end by RDSO or any vigilance organization: In case samples are picked up from consignee end by RDSO or any vigilance organization, three samples shall be picked up and initially 1st sample shall be tested and if it is passed to conform to the

Page No. Effective From Valid Till Master List No. Version No.

Page 4 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

requirements of the specification/drawings, no more tests need to be done. However, as soon as 1st sample fails, consignee shall be advised about the same with the direction that no further material from the suspect lot shall be issued / consumed. Decision on 2nd/3rd sample to be taken within four weeks. In case 2nd/3rd sample fails, then the said lot shall be considered as rejected. Consignee shall be informed immediately and the further action shall be taken by the consignee as per Railway Board’s letter No.2000/RS(G)/379/2 dated 13.03.2009 (excluding para 3.0) for material inspected by RDSO.

17. Footnotes/ Remark, whenever provided, may be referred to, for additional information.

18. Issues of a purely technical nature (e.g. specification, drawing, etc.) in respect of QA(Elect.) controlled items should also be addressed to the concerned design Directorates.

19. Contact Addresses for clarification:

19.1 Office address and phone no. of different Directorate Heads are as follows:

S.N. Directorate Designation Phone no.

E-mail Address

1 Electrical

Directorate

EDSE (Co-

ordination)

0522-

2450374 [email protected]

2 PS&EMU

Directorate

ED/PS&EMU 0522-

2454070 [email protected]

3. Traction Installation Directorate

Sr. ED /TI 0522-

2450709

[email protected]

4. QA (Elect.) Directorate

ED/EM 0522-

2455109

[email protected]

5. Energy Management Directorate

ED/EM 0522-

2455109

[email protected]

19.2 Contact details of controlling ED/ Directors:

Controlling ED/ Director of the item is the right person to be contacted on

matters relating under approval/technical matters. The contact details of

controlling ED/ directors are as follows:

Sl.

No

Directorate Designation Cell No. Fax No.

(0522-)

E-mail ID

1. Electrical EDSE 9794863131 2450374 [email protected]

DSE/TPL 9794863196 2465737 [email protected]

JDSE/C&S 9794863367 2465754 [email protected]

DSE/PS&SC 9794863133 2450374 [email protected]

Page No. Effective From Valid Till Master List No. Version No.

Page 5 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

DSE/TM 9794863138 2465716 [email protected]

2. Traction

Installation

ED/TI 9794863132 2465762 [email protected]

DTI/OHE/E 9794863134 2465765 [email protected]

DTI/OHE/D 9794863253 2465731 [email protected]

DTI/PSI 9794863250 2465763 [email protected]

3. PS&EMU DSE/TL&AC 9794863258 2465738 [email protected]

DSE/PE& Battery

9794863121 2465717 [email protected]

DSE/3Ph.EMU &Metro

9794863258 2462406 [email protected]

DSE/Conv. EMU

9794863252 2450651 [email protected]

DSE/MRVC 9794863238 2451776 [email protected]

4. QA(Elect.) Director/QA (Elect.)

9794863249 2465741 [email protected]

5. Energy

Manageme

nt

Director/EM 9794863107 2461152 [email protected]

m

19.3 The addresses of QA(Electrical) Directorate’s inspection units are follows:

The QA(Electrical) Directorate has inspection cells located at the following

addresses for carrying out various inspection activities at those locations:

S.

No

Inspecti

on Cell

Designation Cell No. Fax No. E-mail ID

1. Bhopal ED/Inspectio

n/

Bhopal

9752031000 0755-

2500416

[email protected].

gov.in

2. Jhansi Director/QA

(Elect.)

9794863249 0522-

2465741

[email protected]

m

20. For compliance to Rly Bd’s letter no. 2010/RS (G) 363/1 dt 05.07.2012

regarding ‘Public Procurement Policy’ for goods procured and services

rendered by Micro and Small Enterprises (MSEs),data of approved vendors

identifying MSEs and among them those belonging to SC/STs have been

provided under column ‘Category’ &‘Ownership’ for enterprise/firm’s category

Page No. Effective From Valid Till Master List No. Version No.

Page 6 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

and its ownership respectively in the table of ‘Details of the Vendors’ in the

following manner:-

Category of Firm/Enterprises-‘M’ for Micro Enterprises, ‘S’ for Small Enterprises

and ‘OTH’ for Other than Micro/Small Enterprises.

Ownership of Firm/Enterprises-‘SC’ for Scheduled Castes, ‘ST’ for Scheduled

Tribes and (OTH) for Other than Scheduled Castes/Scheduled Tribes.

21. The names of sister concerns have been mentioned against each item of List

of Approved Vendors wherever applicable. This should be kept in view

(wherever applicable) to highlight the fact that the competing firms are sister

concerns while dealing with Tenders.

22. Railway Board’s guidelines for dealing with Cartel formation: Some of the

important letters issued by Rly. Boards on matters relating to Cartel formation

by vendors are as follows:

i) Rly. Board’s letter No.2001/RS(G)/779/4 dated 05.08.2002

ii) Rly. Board’s letter No.99/RS(G)709/1 dt 03.05.2005

iii) Rly. Board’s letter No.2005/RS(G)/709/1 dt 17.11.2006

iv) Rly. Board’s letter No.2001/RS(G)/779/4 dt 12.12.2006

However, the procuring agency should also refer to any further

instructions issued by Rly. Board on the above subject, if any

22.1 Rly. Bd’s letter no.2001/RS(G)/779/4 dt 05.08.2002, is reproduced as follows:

No.2001/RS(G)/779/4 New Delhi dt 05.08.2002

The General Managers,

All Indian Railways Including CLW, DLW, ICF, RCF & WAP East Coast Railway, Bhubaneshwar, East Central Railway, Hajipur, North Central Railway, Allahabad, North Western Railway, Jaipur, South Western Railway, Banglore, West Central Railway, Jabalpur,

The General Manager (Const),

N.F. Rly.Guwahati.

CAOs (Const), All Indian Railways (except NF Rly)

The Director General, RDSO, Lucknow

The General Manager,

Page No. Effective From Valid Till Master List No. Version No.

Page 7 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Central Organisation for Rly. Electrification, Allahabad

The General Manager, Metro Railway, Kolkata

CAO, Diesel Component Works, Patiala

CAO, COFMOW, Rly. Offices Complex, Tilak Bridge, New Delhi.

Sub: Cartel formation by approved vendors.

A number of references have been received from Railways/PUs

regarding cartel formation by approved vendors and consequent

substantial increase in rates in tenders. In such cases, even the

negotiations have not helped in obtaining significant reduction in prices.

This issue was discussed in detail in the 56th Conference of Controller of

Stores at Rly. Bd on 13th/14th June, 2002 and it emerged that most of the

approved vendors are taking undue advantage of Railways policy of bulk

quantity procurement only from approved sources.

2. After having considered the matter in detail, it has been decided that the

tender documents may include following conditions.

a) Whatever all or most of the approved firms quote equal rates and

cartel formation is suspended. Railways reserve the right to place

order on one or more firms with exclusion of the rest without

assigning any reasons thereof.

b) Firms are expected to quote for a quantity not less than 50% of

tendered quantity. Offers for quantity less than 50% of tendered

quantity will be considered unresponsive and liable to be rejected in

case cartel formation is suspected. Railways, however, reserve the

right to order on one or more firm any quantity.

c) The firm who quote in cartel may be warned that their names are likely

to be deleted from list of approved sources.

3. Selection of one or more firms as per Para 2(a) above, may be on the

basis of past performance records, capability, capacity, quality

performance, location after sales service response etc. subjects to rates

being considered reasonable. Wherever tendered quantity is quite large

and the capacity of approved firms individually is small, minimum 50%

quantity limit as per para 2(b) may be suitably modified in tender

conditions. Further, Railways may report the details of firms found

involved in forming cartel to source approving authority for considering

down gradation/deletion of names of such firms from list of approved

sources.

Page No. Effective From Valid Till Master List No. Version No.

Page 8 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

4. The instructions contained in Board’s letter no.99/RS(G)/709/1. Dt

6.09.99 of ordering not more than 15% of quantity of Part II approved

sources and 5% of quantity on new source are to be followed in normal

circumstances. Wherever there is suspected cartel formation from

approved sources, after recording the reasons, railways are permitted to

place orders on Part II sources and new sources beyond 15 % and 5%

respectively.

5. Despite above measures, if there is not success in breaking cartel.

Further recourse as may be deemed fit, including taking up the matter

with MRTP commission or proposed competition commission of India

(as and when it is set up) may be considered.

6. This issue with concurrence of finance directorate of Ministry of

Railways.

Sd/-

(P.C. Sharma)

Executive Director Railway Stores (G)

Railway Board

No. 2001/RS(G)/779/4

Copy to:

The COSs, all Indian Railways/Production Units.

FA & CAOs, all Indian Railways & Production Units.

Executive Director, Iron & Steel 3, KoilaGhat Street, Kolkata.

The Director of Audit, All Indian Railways.

The Managing Director, RITES, New Delhi House, Barakhamba Road, New Delhi.

Sd/-

(P.C. Sharma)

Executive Director Railway Stores (G)

Railway Board

Page No. Effective From Valid Till Master List No. Version No.

Page 9 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Copy to :

AM(RS), AM(L), AM(ME), AM(PU), AM(F), AM(CE), AM(TELE), AM(Sig), EDRS

(C), EDRS(P), EDRS(S), EDV(v), EDF(S), EDME(Traction), EDEE(Dev), EDEE

(G), F(S)-I, F(S)-II, and all other offcers and Branches of Stores Dte.

Sd/-

(P.C. Sharma)

Executive Director Railway Stores (G)

Railway Board

Page No. Effective From Valid Till Master List No. Version No.

Page 10 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Page No. Effective From Valid Till Master List No. Version No.

Page 11 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Page No. Effective From Valid Till Master List No. Version No.

Page 12 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Page No. Effective From Valid Till Master List No. Version No.

Page 13 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Page No. Effective From Valid Till Master List No. Version No.

Page 14 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Page No. Effective From Valid Till Master List No. Version No.

Page 15 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Page No. Effective From Valid Till Master List No. Version No.

Page 16 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Page No. Effective From Valid Till Master List No. Version No.

Page 17 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Page No. Effective From Valid Till Master List No. Version No.

Page 18 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Page No. Effective From Valid Till Master List No. Version No.

Page 19 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Page No. Effective From Valid Till Master List No. Version No.

Page 20 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

INDEX

P A R T ‘A’ : ELECTRIC LOCO ITEMS

CHAPTER

NO.

CHAPTER TITLE S.N. ITEM PAGE

CHAPTER-I

Items being dealt by

Electrical Directorate

A Brake System( CCB, E-70 ) of 3-phase locomotives

1. Brake System for 3-phase locomotives 25

B Main Compressor

2. Main Compressor 25

C All the Bearing Used in Locomotives

3. TM / MSU / Auxiliary Bearings 25

4. Axle Box Bearing 27

5. Bearings for Aluminium Gear Case of WAP5 27

D Rubber Item for 3-Phase Locomotive

6. Rubber Components for transmission system of 3-phase

locomotives

27

7. Rubber Components for Brake system for 3-phase

locomotives

27

E Cable and Conduit

8. Cable Transit System with EPDM Rubber Modules 27

9. CABLES 28

F New Technology Item

10. High Reach Pantograph for Electric locomotives 29

Page No. Effective From Valid Till Master List No. Version No.

Page 21 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

CHAPTER – II REGION-WISE LIST

OF FIRMS & THEIR

ADDRESS

ELECTRIC LOCO ITEMS 31-38

P A R T ‘B’: EMU, TL & AC ITEMS

CHAPTER-III

Items being dealt by PS&EMU Directorate EMU EQUIPMENTS

1. Lubricants 39

CHAPTER-IV

Items being dealt by PS&EMU Directorate

EQUIPMENT FOR TRAIN LIGHTING & AIR CONDITIONING

1. Battery 41

2. ERRU 42

3. Roof Mounted AC Package Units 42

4. 415 V, 3-phase induction motor for roof mounted AC

package units.

43

5. 25 kVA under slung inverter 43

6. Battery Charger 43

7. DA Set for Power Car 44

8. Inter Vehicle Coupler 45

9. Switch Board Cabinet 45

10. Flexible Polymide conduit with its end fittings &

accessories

48

11. Micro Processor Controller 48

CHAPTER – V REGION-WISE LIST OF

FIRMS & THEIR

ADDRESS

EMU, TRAIN LIGHTING & AIR CONDITIONING ITEMS 50-72

Page No. Effective From Valid Till Master List No. Version No.

Page 22 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

PART ‘C’: 25 kV AC TRACTION INSTALLATION ITEMS

CHAPTER –VI

Items Being Dealt By Traction Installation Directorate EQUIPMENTS & CONDUCTORS FOR 25 KV AC TRACTION INSTALLATION

1. Transformer and other TSS equipments 73

2. Switchgear 75

3. HDGC Copper contact wire 75

4. Catenary wire 76

5. Supervisory control and data acquisition system

(SCADA)

76

6. Panel and relay 76

7. Shunt capacitor 78

8. Bushing, post and operating rod insulator 78

9. Composite Insulator for OHE and associated fittings 79

10. Regulating equipment (ATD) - Three pulley type and

stainless steel wire rope

80

11. Short Neutral Assembly (Phase Break) 80

12. Fittings for OHE (Forged ) 81

13. Tools & Plant Items 82

14. Galvanise Stranded Steel Wire 82

Page No. Effective From Valid Till Master List No. Version No.

Page 23 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

Chapter – VII

Items Being Dealt By Traction Installation Directorate for 2X25 kV AT Traction Installation System

1. Transformers 83

2. Switch Gear 83

3. Control & Relay Panel, Relays, Series Capacitor And

Shunt Capacitor

83

4. Condenser Bushings 84

CHAPTER – VIII REGION WISE LIST OF FIRMS & THEIR ADDRESS

TRACTION INSTALLATION ITEMS 85-93

P A R T ‘D’ :ITEMS DEALT BY QA (ELECTRICAL) DIRECTORATE

CHAPTER – IX Items being dealt by

QA(Electrical) Directorate

(A) PS &EMU ITEMS :

1 Batteries 94

2 Dry Type Air Filter 96

3 Roof Mounted AC Package Units 97

4 Electronic Time Delay Relay for AC coaches 97

5 Battery Charger 98

(B) 25 KV AC Traction Installation Items

1 POST INSULATORS 99

2 OPERATING ROD INSULATOR 100

3 INSULATORS FOR OHE AND ASSOCIATED FITTINGS 100

4 TOOLS & PLANT ITEMS 102

Page No. Effective From Valid Till Master List No. Version No.

Page 24 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

CHAPTER – X LIST OF FIRMS & THEIR

ADDRESS

QA ( ELECTRCAL) ITEMS 103-110

PART-‘E’: ITEMS DEALT BY ENERGY MANAGEMENT DIRECTORATE

CHAPTER – XI Items dealt by Energy

management Directorate

1 Passenger Elevator 111

2 Passenger Escalator 111

CHAPTER – XII Standard Mailing List

112-117

Page No. Effective From Valid Till Master List No. Version No.

Page 25 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

PART-A:

Electric Loco items

Chapter: I- Items dealt by Electrical Directorate

S.No. ITEM Current Spec. No / Drg No. / STR No.

VENDORS FOR DEVELOPMENT ORDERS Annual Production Capacity

REMARKS

A Brake System( CCB, E-70 ) of 3-phase locomotives

1 Brake System for 3-phase

locomotives

For WAP-5,

CLW/MS/10/031 Alt.6

For WAG-9 Co-Co,

CLW/MS/3/001 Alt .13

--

B Main Compressor

2.1 Main Compressor

(Lubricated)

for WAG9/WAP5/ WAP7

(1750 LPM Capacity)

CLW / ES / 3/0100 Alt. ‘E’ -- …

2.2 Oil Free Main Compressor

for 3-Phase Electric &

WAP-4 Locomotives (1750

LPM Capacity)

RDSO/2008/EL/SPEC/0076

(Rev ‘2’)August 2013

--

C All the Bearing Used in Locomotives

3.0 TM / MSU / Auxiliary Bearings

Page No. Effective From Valid Till Master List No. Version No.

Page 26 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. ITEM Current Spec. No / Drg No. / STR No.

VENDORS FOR DEVELOPMENT ORDERS Annual Production Capacity

REMARKS

3.1 Bearing for traction motor type HS1050Er /HS15250A

NU-330 & NH-324

NEI, Jaipur (Brand name- NBC) PE::TS2-NU330EL1BX1CS188P6 (Shoulder Guided) CE:TS2-NH324L1BX1CS175MP6 (Shoulder Guided)

3.2 Bearings for traction motor TAO-659

NU-328 & NH-318

-----

3.3 Auxiliary Machine

Bearings (including 3-

phase Locomotives&

EMUs)

- 1. Tata Steel Limited (Bearing Division)

Kharagpur

2. NRB Bearings Limited Jalna

Maharashtra

3. Texpin Bearings Limited Ranpur

Ahmedabad

3.4 Suspension bearing for

Hitachi/TAO-659 Traction

Motor

M/s NEI, Jaipur

(PE:M249747/710)

(CE:M349547/510)

3.5 3 Phase Locomotive

Traction Motor Bearing for

TM type 6FRA6068

NU2236 & NJ320 --

3.6 3 Phase Locomotive Traction Motor Bearing of TM type 6FXA7059

NU224 & NH219 --

3.7 Suspension Tube Bearings for WAG9/ WAP7 locomotives

NU 1964 & NH1044

M/s NEI / Jaipur DE: NU 1964 to NEI Drawing No. PESD 3454 Mod. ‘A’ NDE: NH 1044 to NEI Drawing No. PESD 3453 Mod. ‘B’

Page No. Effective From Valid Till Master List No. Version No.

Page 27 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. ITEM Current Spec. No / Drg No. / STR No.

VENDORS FOR DEVELOPMENT ORDERS Annual Production Capacity

REMARKS

4 Axle Box Bearing

4.1 For WAP5 Locomotives TBU- 150 --

4.2 For WAG9/ WAP7

Locomotives

CRU 150 M/s FAG Bearings India Ltd Vadodara F- 807259.02.ZL (With greasing hole )

5 Bearings for Aluminium Gear Case of WAP5

Main Gear bearing L 558548 – L 558510 - --

Intermediate Gear bearing M 432148A – M 432111 --

Pinion bearing 798-792 --

D Rubber Item for 3-Phase Locomotive

6 Rubber Components for transmission system of 3-phase locomotives

6.1 Spheribloc for three phase electric locomotive

RDSO/2007/EL/SPEC /0051 Rev.’2’

-- --

6.2 Elastic Ring for three phase electric locomotive

RDSO/2007/EL/SPEC /0053 Rev.’0’ with Amendt. No 1, Jul 10

1. M/s Sequoia Safety Product Pvt. Ltd., Ghaziabad.

7 Rubber Components for Brake system for 3-phase locomotives

7.1 a. Rubber Components / Kits for E-70-brake system

--

7.2 b. Rubber Components /Kits for CCB system

--

E Cable and Conduit

8 Cable Transit System

Page No. Effective From Valid Till Master List No. Version No.

Page 28 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. ITEM Current Spec. No / Drg No. / STR No.

VENDORS FOR DEVELOPMENT ORDERS Annual Production Capacity

REMARKS

8.1 Cable Transit System with EPDM Rubber Modules

RDSO/2008/EL/SPEC/0067 (Rev ‘2’) of January 2015

1. M/s Roxtec India Pvt. Ltd. Gurgaon . 2. M/s Wallmax India Enterprises Pvt. Ltd. Faridabad

9.0 Cables

9.1 Thin walled flexible elastomeric cables

with copper conductors

for working voltages

(i) upto 750 volts and

(ii) above 750 volts upto 1.8/3.0 kv for tap changer electric locomotives , AC/DC EMU, BG AC EMU & MEMU/ coaching stock

( Chemical curing process / Electron Beam Irradiation curing process) *

RDSO Spec no. ELRS/SPEC/ELC/

0019, Rev ‘3’ of February 2017

a. UNIVERSAL / Satna (1000 km) with chemical curing Process )

b. Apar Industries Ltd ( Unit: Uniflex cables) Mumbai (950 kms) ( with chemical curing Process )

c. M/s Leoni Studer AG, Herrenmattstr 20, Postfach 63, CH-4658, Daniken Switzerland( With Electron Beam Irradiation Curing process )

d. * # M/s Quadrant Cables Private Limited, Mohali (With Electron Beam Irradiation Curing Process

9000 Kms

*(i) Up to 750 volts -

For sizes up to 50 sq

mm.

# (ii) above 750 volts

up to 1.8/3.0 kv- For

all sizes except 19

core x 4 sq mm

Note: As per clause no. 2.0 (Credential) of RDSO’s STR no. RDSO/2017/EL/STR/0087 Rev ‘0’ dated 10.02.2017 AERB certification is mandatory before the supply of cable to Railways.

9.2 Thin Walled Cable for 3-phase locomotives

Single Core Cable CLW/ES/3/0458

1. Apar Industries Ltd ( Unit : Uniflex cables) Mumbai 2. *M/s Quadrant Cables Private Limited, Mohall (With Electron Beam Irradiation Curing Process)

9000 Kms

* As per clause no. 2.0 (Credential) of RDSO’s STR no. RDSO/2017/EL/STR/0087 Rev ‘0’ dated 10.02.2017 AERB certification is mandatory before the

Page No. Effective From Valid Till Master List No. Version No.

Page 29 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. ITEM Current Spec. No / Drg No. / STR No.

VENDORS FOR DEVELOPMENT ORDERS Annual Production Capacity

REMARKS

supply of cable to

Railways.

Multi Core Cable CLW/ES/3/0459

Apar Industries Ltd ( Unit:Uniflex cables) Mumbai

9.3 Single Core & Multi Core a) Elastomeric Cables (for

loco & EMU) b) HRPVC cables (for

EMUs & coaches)

E-14/01 (Rev.2) 1993 (part I & II) E-14/01 (Rev.2) 1993 (Part III)

1. M/s. Nangalwala Industries (P) Ltd Alwar @ 2. M/s Mansfield Cable Co. Noida 3. M/s KEI Industries Ltd., Bhiwadi Alwar 4. M/s Bhuwal Insulation cable Pvt Ltd, Mumbai *

@ only for E-14/01 (Rev.2) 1993 (part I & II) * only for E-14/01 (Rev.2) 1993 (part II)

9.4 Zero Halogen Low Smoke Cables for Metro coaches

E-14/04 (Rev.1) 1998

1. Radiant RSCC Specialty Cable Pvt. Ltd Hyderabad 2. M/s KEI Industries Ltd., Bhiwadi Alwar

F New Technology Item

10. High Reach Pantograph for Electric locomotives

RDSO/2007/EL/SPEC/ 0054 Rev.’2’ of Nov 2015

1. *M/s Stone India Ltd. Kolkata - as per spec. Rev. ‘0’ ) 2. #M/s Schunk Metal & Carbon (I) Pvt. Ltd., Bangalore ( Type WBL-85 HR ) 3. *M/s. Contransys Pvt. Ltd., Kolkata - as per spec. Rev. ‘0’ ) 4. *M/s Faiveley Transport Rail Technologies India Ltd. / Hosur (Type LX 3600 as per spec. Rev.‘0’)

*Approved as per RDSO specification no. RDSO /2007/EL/SPEC/ 0054 Rev. ‘0’. However revalidation of M/s. Stone India Ltd. (Type ABOH), M/s. Contransys Pvt. Ltd (IR05HR)M/s Faiveley Transport Rail Technologies India Ltd. (Type LX 3600

Page No. Effective From Valid Till Master List No. Version No.

Page 30 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. ITEM Current Spec. No / Drg No. / STR No.

VENDORS FOR DEVELOPMENT ORDERS Annual Production Capacity

REMARKS

PN) as per revised specification No. RDSO/2007/EL/SPEC/ 0054 Re v. ‘2’ is awaited. #Validated as per revised specification No. RDSO/2007/EL/SPEC/ 0054 Rev.’2’

Page No. Effective From Valid Till Master List No. Version No.

Page 31 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

CHAPTER-II

REGION-WISE LIST OF FIRMS AND ADDRESSES FOR ELECTRIC LOCO ITEMS

EASTERN REGION:

S.N. Office Address / Works Address / Office Phone,Fax No.& E-Mail Address

Category Ownership ITEM

1 2 3 4 5

1. M/s. Contransys Pvt. Ltd., 16 Hare Street Kolkata – 700001; Works Address – DIC, Industrial Area Plot No – 2 Baddi, Dist – Solan, H.P. 173205 , Ph -033-22482391 Fax:033-22489382 Info@ contransys.com

OTH OTH High Reach Pantograph

2. Stone India Ltd., 16 Taratalla Road, Kolkata-700088. Works Address – (i) Stone India Ltd., 16 Taratalla Road, Kolkata-700088. (ii) M/s Stone India Ltd., 182, Gurumajara Baddi, Tehsil Nalagarh, Dist.- Solan - 174101 ( H.P.), Ph : 033-24014661–68, 01795-276262,+91 9318667693Fax:033-24014886 01795 276261, [email protected]@cal.vsnl.net.in [email protected]@stoneindia.co.in

OTH OTH High Reach Pantograph

3. 1. M/s. TATA Steel Limited , Bearing Division, Registered office : BombayHouse, 24 Homi Mody Street, Mumbai 2. Marketing office:TATA cebtre, 43, JN Road, Kolkata-700 071 ; Works Address – Nimpura Industrial Growth Centre, P.O. Rakhajungle, Dist: West Midnapur, West Bangal , Ph : Marketing033 22881962 28815588 ,Works Ph :0322 – 233317 / 233618 , Fax: Marketing:033 22881962Works:03222 233353Cheifm&[email protected] [email protected]

OTH OTH Auxiliary Machine Bearings

Page No. Effective From Valid Till Master List No. Version No.

Page 32 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

CENTRAL REGION:

S.No.

Office Address / Works Address / Office Phone ,Fax No.& E-Mail Address

Category Ownership Items

1 2 3 4 5

1. Office Address :National Enggineering Industries Ltd, Khatipura Road, Jaipur – 302006 , Works Address : same as office address Ph : 0141-223221, Fax: 0141-2224382/ 221926/223213 shivdutt@[email protected]

OTH OTH i) Bearing for traction motor type HS15250Er/HS15250A

ii) Suspension bearing for Hitachi/TAO-659 Traction Motor

iii) Suspension Tube Bearings for WAG9/ WAP7 locomotives

2. Universal Cables Ltd., P.O. Box No. 9, Satna (MP) – 485001 Works address: -do- Phone No: 257121-257127 Fax no: 0762-257131 [email protected]

Thin walled flexible elastomeric cables with copper conductors

For working voltages (i) upto 750 volts and (ii)above 750 volts upto 1.8/3.0 kv for Tap

Changer Electric Locomotives , AC/DC EMU, BG AC EMU & MEMU/coaching stock

(Chemical curing process / Electron Beam Irradiation curing process)

3. NRB Bearings Limited, works address: C-6, MIDC, Additional industrial area, Jalna -431213 Maharashtra Office Address: Dhannur, 15, Sir P.M. Road, Fort, Mumbai – 400 001 Fax No. : 022-22660412 Phone No. : 02482 – 220226 Email: [email protected]

Auxiliary Machine Bearings

Page No. Effective From Valid Till Master List No. Version No.

Page 33 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

WESTERN REGION: S.No

. Office Address / Works Address / Office Phone /Fax No. / E-Mail Address

Category Ownership Items

1 2 3 4 5

1. Office Address:FAG Bearing India Ltd, Maneja, Vadodara-390013, India Works Address: same as office address Phone:0265-6602000-1-2-3-4, Fax:0265-638804/ 6602473 E-mail:[email protected]

OTH OTH Axle Box Bearing and Complete Axle Box Assembly with Bearing for WAG9/WAP7 locomotive-CRU 150

2. Siemens Ltd, Nasik works plot No C-1, Additional Industrial Area MIDC , Ambad , Nasik – 422010; Works Address; -Do- Ph. 022-33265374, 33265382

Hotel Load Converter for WAP-7 locomotives (2X500 KVA)

3. Office address :Apar Industries Ltd ( Unit:Uniflex cables) 12/13, Jyoti Wire House , 23 – A Shah Industrial Estate, Off Veera Desai Road, Andheri (W) Mumbai-400053. Main work Address -: Apar Industries Ltd, Plot No. 158-163 GIDC, Umbergaon-396171, Dist: Valsad, Gujarat. Additional work Address:Apar Industries Ltd, Khatalwada, KhatalwadaManekpur Road, Tal – Umbergaon, Valsad -396120 (Gujrat) for Item: 1. Thin walled flexible elastomeric cables with copper conductors for working voltages (i) upto 750 volts and (ii) above 750 volts upto 1.8/3.0 kv for tap changer electric locomotives , ac/dc emu, bg ac emu& memu/coaching stock ( Chemical curing process / Electron Beam Irradiation curing process) 2. Single Core & Multi Core : a) Elastomeric Cables (for loco & EMU) b) HRPVC cables (for EMUs & coaches) 3. Zero Halogen Low Smoke Cables. Office phone : 022-26740001/2/3 & 0260-2562412, 2563412,

1. Thin walled flexible elastomeric cables with copper conductors for working

voltages (i) upto 750 volts and (ii) above 750 volts upto 1.8/3.0 kv for Tap Changer Electric Locomotives ,

AC/DC EMU, BG AC EMU & MEMU/coaching stock

(Chemical curing process) 2. Thin Walled Cable for 3- phase

locomotives.

Page No. Effective From Valid Till Master List No. Version No.

Page 34 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No.

Office Address / Works Address / Office Phone /Fax No. / E-Mail Address

Category Ownership Items

1 2 3 4 5

Fax no. 022-26740600 & 0260 – 2562950, 2562954. e-mail :[email protected] , [email protected]

4. Office address: M/s Bhuwal Insulation cable Pvt Ltd 108 , Ardeshir Dady Street , Ravindra Villa, Near C.P. tank circle Works Address: M/s Bhuwal Insulation cable Pvt Ltd , Ankit Industries Estate Gala No. 4 & 5 , Building No. 2 Near MLK Industrial Estate , N. H. -8 , Sativali Road , Vasai Road (E) Dist. Thane- 401208 Fax No. 02223809236 Phone No. 022-66595907,23822877,66362877 Email Id: [email protected]

Single Core & Multi Core -Elastomeric Cables (for loco & EMUs)

5. 3. Texpin Bearings Limited, Works address: Station Road, Ranpur – 382245, Ahmedabad, Gujrat, Office Address: B- 804, Shapath IV, Opp. Kamavati club, S. G. highway, Ahmedabad – 380051 Gujrat Fax No. 2711 238345 Phone No. 2711 – 238190/191 email: [email protected], [email protected]

Auxiliary Machine Bearings

Page No. Effective From Valid Till Master List No. Version No.

Page 35 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

NORTHERN REGION:

S.No.

Office and Works Address / Office Phone / Fax No. / E-Mail Address

Category Ownership Items

1. M/s Anest Iwata Motherson pvt. Ltd ,B-5,Site C, Surajpur Industrial Estate ,Greater Noida-201306 Ph:0120-4600517,256153 Fax: 01275-222-755 Email: [email protected]

Main Compressor for Conventional Locomotive 1000 LPM

2. M/s Roxtec India Pvt. Ltd. D-64-65, Udyog Vihar Phase – V, Gurgaon – 122016 Haryana) India; Works Address – Do - , Ph : +911244006129, 41, 42, 43, 44; 8527199936 / 9999605061, fax : +911244006140 , Web : www.roxtec.com , [email protected]

Cable Transit System with EPDM Rubber Modules

3. M/s Wallmax India Enterprises Pvt. Ltd. 12/6, Golden Peakock Complex, Main Mathura Road, Faridabad – 121003 ( Haryana) India; Works Address – Do - , Ph : + 911292252381 Fax -+ 911292250181 Web: www.wallmax.it , [email protected] , [email protected]

Cable Transit System with EPDM Rubber Modules

4. M/s KEI Industries limited, SP-919, 920, 922, RIICO Industrial area, Phase-III, Bhiwadi-301019 Distt,- Alwar (Raj.) Works address: -do- Fax No: 01493-221731 Phone No: 01493-220106/221731 Email id: [email protected]

1. Single Core & Multi Core : a) Elastomeric Cables (for loco & EMUs) b) HRPVC cables (for EMUs & coaches)

2. Zero Halogen Low smoke Cables.

5. Mansfield Cable Co. B – 41, Sector 6 Noida – 201301. Works address : C-23, Site C Surajpur Industrial Area Greater Noida - 201306 Phone No: 0120-2422275 Fax No: 0120-2422254 [email protected]

S OTH 1. Single Core & Multi Core : a) Elastomeric Cables (for loco & EMUs) b) HRPVC cables (for EMUs & coaches)

6. M/s. Nangalwala Industries (P) Ltd, F- 151- 154, M.I.A. Alwar- 301030 (Rajasthan), Works address: -do- Phone No: 0144-2881375 ,6450222 3095515 Fax No: 0144-2881336 ,2882336 , 2332608 [email protected]

S OTH Single Core & Multi Core a) Elastomeric Cables (for loco & EMU)

Page No. Effective From Valid Till Master List No. Version No.

Page 36 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No.

Office and Works Address / Office Phone / Fax No. / E-Mail Address

Category Ownership Items

7. M/s Quadrant Cables Pvt. Ltd., Mohali, SCO 534, IInd Floor, Sector – 70, Mohali – 160055, Punjab (India) Work Address : M/s Quadrant Cables Pvt. Ltd., Mohali, Vill-Basma, Tehsil-Banur, Dist.-Mohali – 140417, Punjab (India) Phone: 01725098333 Fax: -do- Emai ID: [email protected] &

[email protected]

OTH OTH 1. Thin walled flexible elastomeric cables with copper conductors for working voltages (i) upto 750 volts and (ii) above 750 volts upto 1.8/3.0 kv for Tap Changer Electric Locomotives , AC/DC EMU, BG AC EMU & MEMU/coaching stock (Electron Beam Irradiation curing process) 2. Thin Walled Cable for 3-phase (Electron Beam Irradiation curing process)

8. M/s Sequoia Safety Products Pvt. Ltd. Works: A-34/2/1, Block-I, Site-IV, Industrial Area, Sahibabad, Distt.-Ghaziabad (U.P.) PIN-201010 Office: 4, Jasola, pocket-1, New Delhi -110025 Ph: 011-40554651/52 Fax: 011-40554650 Email:[email protected]

Elastic Ring for three phase electric locomotive

9. M/s Saber Dais Compression Limited,389/13,Street No. 1, Amargarh Colony, Kaithal. (Haryana)-136027. Ph:01746222481 & 22482 Email : [email protected]

Main Compressor for Conventional Locomotive 1000 LPM

Page No. Effective From Valid Till Master List No. Version No.

Page 37 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

SOUTHERN REGION: S.No.

Office and Works Address / Office Phone / Fax No. / E-Mail Address

Category Ownership Items

1. Faiveley Transport Rail Technologies India Pvt Ltd, Post Box No. 39 Harita, Hosur-635109, Tamilnadu ; Works Address – Do - , Ph : 04344-276761 to 276765 Fax:04344-276035 , 276786 [email protected]

OTH OTH High Reach pantograph type LX3600

2. Medha Servo Drives Pvt Ltd, P-4/5B I.D.A. Nacharam, Hyderabad-500076 , Ph : 040-2717 3990 Fax:040-27174908 [email protected] Works Address – Jodimetal Cross Road, Korremula Village: 501301, Ghateshwar Mandal, RR Dist.(AP)

S OTH Hotel Load Converter for WAP-7 Locomotives (2X500 KVA)

3. Schunk Metal & Carbon (India) Pvt Ltd, No 54/2 Whitefield Road, Mahadevapura P.O. Bangalore-560048. , Ph : 80-28518506/ 8507/6708/8541, Fax:080-28516713 / 8542 [email protected] Works Address – Do -

S OTH High reach Pantograph Type WBL 85 HR

4. M/s Radiant RSCC Specialty Cables Pvt. Ltd, B-1, Industrial Estate, Sanathnagar, Hyderabad-500018 Works address: -do- Add. Work - Plot No – 19/A AP 11 C, Industrial Park Muppireddypally, (Village) Toopran (Mandal), Medak – Dist, A.P. -502336 040-23704470/71/72/ 73 040-23703421 [email protected]

OTH OTH Zero Halogen Low Smoke

Page No. Effective From Valid Till Master List No. Version No.

Page 38 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

FIRMS ABROAD: S.No Office and Works Address / Office Phone /Fax No. / E-Mail

Address Category Ownership Items

1. M/s Timken Corporation , 4500 Mount Pleasant Street NW, North Canton, OHIO, 44720, USA. Works Address – Do -

i) Suspension bearing for Hitachi/TAO-659 Traction Motor ii) Bearing for Aluminium gear case of WAP-5

2. ZF Bhantechnic GmbH Adelheidstrabe 40, D-88046, Friedrich shafen, Germany Works Address – Do – , Ph : 0049-7541306-01 Fax: 0049-7541306-100

Crowned gear coupling for WAP-5

3. Leoni Studer AG, Herrenmattstr 20, Postfach 63, CH-4658, Daniken Switzerland Works address: -do- In India- M/s Leoni Cable Solutions (India) Pvt Ltd. Indo Space Rohan Industrial Park gate No – 428, Village – Mhalunge Off. CHakan – Telegaon Road, Taluka –Khed Pune – 410501 Phone no: +41(0) 622888383, 02135-391600 Fax No: +41(0) 6228882830 02135-391600 [email protected], www.leoni.com

Thin walled flexible elastomeric cables with copper conductors for working voltages (i) up to 750 volts and (ii) above 750 volts up to 1.8/3.0 kv for Tap Changer Electric Locomotives ,

AC/DC EMU, BG AC EMU & MEMU/coaching stock

( Chemical curing process / Electron Beam Irradiation curing process)

Page No. Effective From Valid Till Master List No. Version No.

Page 39 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

PART-B CHAPTER III- EMU EQUIPMENT

S.No. EQUIPMENT CURRENT

SPECN./DRAWING NO

Developmental Sources ANNUAL

PRODUCTION

CAPACITY

REMARKS

1 2 3 4 5 6

1. LUBRICANTS

1.1 ARMATURE BEARING GREASE

1.1.1 Traction Motor 4601 AZ/BX/BW of BHEL

NIL

1.1.2 Fuji TM GGR 125ZY NIL

1.1.3 TDK 5620 A / BHEL3701 AZ and 133 AY / 3601 AZ

NIL

1.2 AXLE SUSPENSION BEARING OIL

1.2.1 TDK 5620 A /

BHEL 3701 AZ

NIL

1.2.2 4601 AZ/BX/BW NIL

1.2.3 Fuji TM GGR 125ZY NIL

1.3 GEAR CASE OIL

1.3.1 133 AY / 3601 AZ NIL

Page No. Effective From Valid Till Master List No. Version No.

Page 40 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. EQUIPMENT CURRENT

SPECN./DRAWING NO

Developmental Sources ANNUAL

PRODUCTION

CAPACITY

REMARKS

1 2 3 4 5 6

1.3.2 TDK 5620 / BHEL 3701

AZ

NIL

1.3.3 4601 AZ/BX/BW NIL

1.3.4 Fuji TM GGR 125ZY NIL

Page No. Effective From Valid Till Master List No. Version No.

Page 41 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

CHAPTER-IV

EQUIPMENT FOR TRAINLIGHTING & AIR-CONDITIONING

S.No

EQUIPMENT CURRENT SPECN. Developmental Sources ANNUAL

PRODUCTION

CAPACITY

REMARKS

1 2 3 4 5 6

1.0 Battery

1.1 Battery for train lighting

1.1.1 120 Ah (VRLA) RDSO/PE/SPEC/AC/0009

– 2014 (Rev. ‘2’)

1. M/s Exide(MET 6V-120 Ah) 2. M/s Microtex Energy

(6VF120PP) 3. M/s Southern (PP-6V 120

Ah) 4. M/s United Lead Oxide,

Kundaim (6 VF120 PP )

1.2 Battery for Air-conditioning

1.2.1 1100Ah VRLA RDSO/PE/SPEC/AC/000

9 – 2014 (Rev. ‘2’)

NIL

1.2.2 650 Ah VRLA cell RDSO/PE/SPEC/AC/0009

– 2014 (Rev. ‘2’)

1. M/s Amara Raja (R2650) 2. M/s HBL (F 650 PP) 3. M/s Exide (MET 650 Ah) * 4. M/s Microtex (2VF 650 PP)

*

*Revalidation as

per Rev. ‘2’

specification is

pending.

1.2.3 12 V, 70 Ah VRLA RDSO/PE/SPEC/AC/0009

– 2014 (Rev. ‘2’) 1. M/s HBL (LR 12V 70)

Page No. Effective From Valid Till Master List No. Version No.

Page 42 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No

EQUIPMENT CURRENT SPECN. Developmental Sources ANNUAL

PRODUCTION

CAPACITY

REMARKS

1 2 3 4 5 6

2.0 ERRU

2.1 ERRU for 4.5 kW

Alternator

RDSO/PE/SPEC/AC/

0013-2011 (Rev. ‘3’)

1. M/s KEL (Kundara)*

2. M/s Stone India Ltd.

3. M/s Electronic Equipment

Co. Pvt. Ltd. Kolkata

1. ------

2.240

3. ----

*Revalidation as

per Rev. ‘3’

specification is

pending.

2.2 ERRU for 25 kW

Alternator

RDSO/PE/SPEC/AC/

0013-2011 (Rev. ‘3)

1. M/s KEL(Kundara) *

2. M/s Stone India Ltd.

1.----

2.----

*Revalidation as

per Rev. ‘3’

specification is

pending.

3.0 Roof Mounted AC Package Units

3.1 Roof mounted AC

package unit for LHB

variant AC coaches.

RDSO/PE/SPEC/AC/

0061 – 2005 (Rev.’1’)

1. M/s EssEss Kay Engg. Co. (P) Ltd., Kapurthala

2. M/s Daulat Ram Industries, Haridwar

3. M/s Daulatram Engineering Services Pvt. Ltd,SimraiMandideep(MP)

1.----

2.500

3.2 Roof mounted AC

package unit for Double

Decker EOG AC

coaches.

RDSO/PE/SPEC/AC/

0134 – 2009 (Rev.’0’)

1. M/s Sidwal Refrigeration, Faridabad

2. M/s Intec Corporation, Selaqui

3. M/s Lloyd Electric, Bhiwadi

Page No. Effective From Valid Till Master List No. Version No.

Page 43 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No

EQUIPMENT CURRENT SPECN. Developmental Sources ANNUAL

PRODUCTION

CAPACITY

REMARKS

1 2 3 4 5 6

4. M/s Amit Engineers, Baddi

4.0 415 V, 3-phase induction

motor for roof mounted

AC package units.

RDSO/PE/SPEC/AC/

0089 (Rev. ‘0’) with

Amendment 1 & 2

1. M/s CGL, Ahmednagar 2. M/s Daulat Ram Engg.

Services (P) Ltd., Raisen 3. M/s Standard Electrical

Industries, Coimbatore 4. M/s Kapsons Industries,

Jallandhar. 5. M/s Star Electric

Company, Ludhiana

5.0

25 kVA under slung

inverter

RDSO/PE/SPEC/AC/002

4– 2001 (Rev-0) with

Amendment No. 2.

1. M/s Bombardier Transportation Pvt. Ltd., Vadodara @@

2. M/s Signotron (India) Pvt. Ltd. , Kolkata

3. M/s Crompton Greaves Ltd., Pithampur

1. 540 2. ----- 3. -----

@@ Only for

AMC

6.0 Battery Charger

6.1 Regulated Battery

Charger

RDSO/PE/SPEC/AC/0129

-2009 (Rev. 1)

1. M/s IC Electricals Co. Pvt. Ltd., Haridwar

2. M/s Transtel Engineering (P) Ltd. , Baddi (Solan)

Page No. Effective From Valid Till Master List No. Version No.

Page 44 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No

EQUIPMENT CURRENT SPECN. Developmental Sources ANNUAL

PRODUCTION

CAPACITY

REMARKS

1 2 3 4 5 6

7.0 DA Set for Power Car

7.1 Diesel Alternator set 500

kVA , 750 V

RDSO/PE/SPEC/AC/

0084 – 2008 (Rev. ‘1’)

1. M/s DeevGenset, Silvasa * 2. M/s Cummins India Ltd.,

Pune @

*Approved for M/s

Crompton

Greaves Ltd.

Alternator Model

No. G2R355MA

with M/s Greaves

Cotton CPB -II

Compliant Engine

Model No.

12V14TAG23

@ (i)Approved for

M/s Cummins

India Ltd. CPCB-II

complaint diesel

engine model no.

KTAA19G10 and

M/s BHEL-EML

Alternator Model

No. TA-3560L7-

SP.

(ii)Approved for

M/s Cummins

India Ltd. CPCB-II

Page No. Effective From Valid Till Master List No. Version No.

Page 45 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No

EQUIPMENT CURRENT SPECN. Developmental Sources ANNUAL

PRODUCTION

CAPACITY

REMARKS

1 2 3 4 5 6

complaint diesel

engine model no.

KTAA19G10 and

M/s. KEC

Alternator Model

No. 4AB355/7.

8.0 Inter Vehicle Coupler

8.1 ZS Coupling 400 A 750 V EDTS 105 Rev-E with

Amend 1, 2 & 3

1. M/s Prime Electronics,Sonepat

8.2 500A 750V Inter

Vehicular (IV) Coupler

RDSO/PE/SPEC/AC/017

7-2013 (Rev.0)

1. M/s S. Internationals, Mumbai

2. M/s MAA Laxmi Industry, Howrah

3. M/s Prime Electronics, Sonepat

9.0 Switch Board Cabinet

9.1 Switch Board Cabinet

for LHB EOG AC

coaches

RDSO/PE/SPEC/AC/

0184-2015(Rev.0)

1. M/s Instrumentation Ltd., Kota #

2. M/s Transtel Engineering (P) Ltd., Baddi #

3. M/s Trinitron Conrol Systems Pvt. Ltd.,Greater Noida #

4. M/s NEC Swithgears& Controls

5. M/s Integ Electronics , New

# Approved with

RCF specification

no. EDTS 073

Rev.D

Amendment ‘6’.

However

revalidation is

pending for

Page No. Effective From Valid Till Master List No. Version No.

Page 46 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No

EQUIPMENT CURRENT SPECN. Developmental Sources ANNUAL

PRODUCTION

CAPACITY

REMARKS

1 2 3 4 5 6

Delhi # 6. M/s Hind Rectifiers Ltd.,

Nashik 7. M/s Trolex India Private

Ltd., Bangalore

8. M/s RSI Switchgear Pvt. Ltd., Kehrani, Alwar #

revised

specification no.

RDSO/PE/SPEC/A

C/0184-2015

(Rev.0).

9.2 Switch Board Cabinet

for Air-conditioning of

LHB power car

EDTS 104 Rev. ‘D’,

Amendment ‘5’

1. M/s Amit Engineers, Baddi 2. M/s Trinitron Control

Systems Pvt. Ltd., Greater Noida

3. M/s Integ Electronics, New Delhi

4. M/s NEC Switchgears & Controls, Mohali

5. M/s RSI Switchgear Pvt. Ltd.,Kehrani, Alwar

9.3 Switch Board Cabinet

for LHB AC power car

for 2x500 kVA DA set

EDTS 103 Rev. ‘D’,

Amendment ‘7’

1. M/s AbrolEngg.,Kapurthala

9.4 Switch Board Cabinet

for LHB SG AC coaches

EDTS 144 1. M/s AbrolEngg., Kapurthala

2. M/s International Switchgear, Chandigarh

3. M/s Stesalit, Baddi 4. M/s Instrumentation Ltd.

Kota

9.5 Switch Board Cabinet

for LHB AC Hot Buffet

EDTS 134 Rev. ‘D’ 1. M/s AbrolEngg., Kapurthala

2. M/s Instrumentation Ltd.

Page No. Effective From Valid Till Master List No. Version No.

Page 47 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No

EQUIPMENT CURRENT SPECN. Developmental Sources ANNUAL

PRODUCTION

CAPACITY

REMARKS

1 2 3 4 5 6

Coach Amendment ‘5’ Kota 3. M/s Amit Engineers,

Baddi

9.6 Switch Board Cabinet

for EOG Type Double

Decker Coaches.

EDTS 327 Rev. A Corr-1,

Amendment ‘1’

1. M/s International Switchgears, Chandigarh *

2. M/s AbrolEngg; Kapurthala*

3. M/s EssEss Kay Engg. Co; Kapurthala*

4. M/s Sidwal Ref. Inds. Ltd; New Delhi *

5. M/s Stesalit Ltd; Kolkata *

6. Trinitron Control Systems Pvt. Ltd., Greater Noida

7. M/s Amit Engineers, Baddi

8. M/s Integ Electronics, New Delhi

* Subject to

revalidation by

RDSO.

9.7 Set of Panels for LHB

EOG Non AC coaches.

EDTS 355 Rev. 1,

Amendment 1 & 2

1. M/s Amit Engineers, Baddi

2. M/s NEC Switchgears; Mohali

3. M/s AbrolEngg; Kapurthala

4. M/s International Switchgears Ltd.;

Page No. Effective From Valid Till Master List No. Version No.

Page 48 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No

EQUIPMENT CURRENT SPECN. Developmental Sources ANNUAL

PRODUCTION

CAPACITY

REMARKS

1 2 3 4 5 6

Chandigarh 5. M/s EssEss Kay Engg.

Co; Kapurthala 6. M/s Trinitron

ControlSystems Pvt. Ltd., Greater Noida

7. M/s Hind Rectifiers Ltd.,Nashik

10.0 Flexible Polymide

conduit with its end

fittings &accessaries

RDSO/PE/SPEC/AC/013

8-2009(Rev.1)

1. M/s M. V. Electrosystems Pvt. Ltd. Faridabad(sizes: NW10,NW12,NW17, NW23, NW29,NW36,NW48)

2. M/s TirupatiPlastomatics Pvt. Ltd.,Jaipur(sizes: NW12,NW17, NW23, NW29,NW36,NW48)

3. M/s International Switchgears Pvt. Ltd., Mohali (sizes: NW12,NW17, NW23, NW29,NW36,NW48)

11.0 Micro Processor Controller

11.1 Microprocessor

controller for roof

mounted AC package

RDSO/PE/SPEC/AC/

0139 - 2009 (Rev. ‘1’)

1. M/s Areca Embedded Systems Pvt. Ltd. Hyderabad

2. M/s Sidwal Refrigeration,

Page No. Effective From Valid Till Master List No. Version No.

Page 49 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No

EQUIPMENT CURRENT SPECN. Developmental Sources ANNUAL

PRODUCTION

CAPACITY

REMARKS

1 2 3 4 5 6

unit for LHB coaches

and double decker

coaches

Faridabad 3. M/s Universal Controls,

Hyderabad

Page No. Effective From Valid Till Master List No. Version No.

Page 50 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

CHAPTER-V

REGION-WISE LIST OF FIRMS AND ADDRESSES FOR EMU, TL AND AC ITEMS

A. EASTERN REGION

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

1. EECPL M/s. Electronics

Equipment Co. Pvt. Ltd.

Office:-

146/2, Old China Bazar

Street, 1st Floor, Kolkata-

700001

Works:-

544, Robindra pally,

Brahmpur, Badamtalla,

P.S. Regent Park,

Kolkata-700096

Fax 033-22901191

Ph 033-22901192

E-mail:

[email protected]

S OTH 4.5 kW ERRU

2. EIL M/s. Exide Industries

Ltd.,

Office:-

91-033-2286-6186

E-mail:

ChandanB@exid

e.co.in

OTH OTH VRLA

Batteries

Page No. Effective From Valid Till Master List No. Version No.

Page 51 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

59E, Chowringhee

Road, Kolkata-700020

Works-

Survey No. 246,

Chichurakanapalli,

Sevaganapallipanchayat

h, Hosurtaluk,

KrishangiriDistt. Tamil

Naidu – 635 103

3. MLI M/s. MaaLaxmi Industry,

Office:-

No. 117, Bellious Road,

Howrah 711 001.

Works:-

Andul Road, Panchpara,

Radhadasi, Howrah-

711313.

Ph. 033-26441267.

Fax: 033-

26448122.

Mob. 9836319527

(S. Bhattacharya)

E-mail:

maalaxmikol@ya

hoo.co.in

500 A 750 V

IV Coupler

4. SIL M/s. Stone India Ltd.,

Office & Works:-

16, Taratola Road,

Fax 91(033) 2401-

4886

Ph. 2401-

E-mail:

info@stoneindia.

co.in

OTH OTH ERRU

Page No. Effective From Valid Till Master List No. Version No.

Page 52 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

Kolkata-700088. 4661/24014668

5. SIPL M/s.Signotron (India) Pvt.

Ltd.,

Office& Works:-

Plot No.J1-6, Block-EP,

Sector-V, Salt Lake

Electronic Complex,

Kolkata – 700 091

9831290695

23577877,

23573481

E-mail:

signomail@vsnl.

net

S OTH 25kVA

underslung

Inverter

B. NORTHERN REGION

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

6. AECPL

M/s.AbrolEngg. Co. Pvt.

Ltd;

Office & Works:-

P.O.Box 2, ‘Abrol House’,

Industrial Area,

Mobile :

09357200001

Fax no. 01822-

232098

Email:

abrolengg@gmail

.com

Switch

Board

Cabinet

Page No. Effective From Valid Till Master List No. Version No.

Page 53 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

Kapurthala-144 601

(Punjab).

7. AEL M/s. Amit Engineers,

Office:-

E-181, IndustrialArea,

Phase – VII, Mohali

(Punjab) – 160055.

Works:

Village Judi Kalan, Distt.

Solan, The. Nalagarh,

Baddi, Himachal Pradesh

- 173205

Ph. 0172-5044640,

41, 44

Fax: 0172-

2236916,

Mob. 9814012801

E-mail:

amit@amitengine

ersbaddi.com /

quality@amitengi

neersbaddi.com /

goel@amitengine

ersbaddi.com

S OTH Roof

Mounted AC

Package Unit

for LHB

variant AC

coaches,

Double

decker

RMPU.

Switch

Board

Cabinet for

EOG Type

Double

Decker

Coaches and

for LHB AC

Hot Buffet

Coaches.

Microproces

sor

controller for

roof

Page No. Effective From Valid Till Master List No. Version No.

Page 54 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

mounted AC

package unit

for LHB

coaches and

double

decker

coaches

8. DRESPL

M/s. Daulat Ram Engg.

Services (P) Ltd.,

Office & Works:-

10/2, NH-12, Simarai,

Raisen (MP).

Ph. 07480-231252,

231253.

Fax 07480-231250.

E-mail:

pulkitsharma@da

ulatram.org

3-phase

induction

motor for

RMPU,

Conventional

Roof

Mounted AC

package Unit

and control

panel.

9. DRIL M/s. Daulat Ram Industries,

Office & works:-

141, 1.1 DC Integrated Industrial Estate, Haridwar – 249403.

email: [email protected]

Ph. 01334-324666

Fax 01334-239193

Mob. 9893029412

RMPU for

LHB variant

AC coaches.

Page No. Effective From Valid Till Master List No. Version No.

Page 55 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

m

10. EEKECPL M/s. EssEss Kay Engg.Co. Pvt. Ltd

Office & Works:-

P.O.Box 8, Kapurthala-144 601 (Punjab)

Fax. 01822-232668

Ph: 01822-232587,

232956,221614-15

Mob. 9814088632

Email: [email protected]

E-mail:

narendra.dubey

@rediffmail.com /

rajeshmy2005@y

ahoo.com /

[email protected]

S OTH Switch

Board

Cabinet of

different

variants.Roo

f mounted

AC Package

units for LHB

variant AC

coaches

11. ICECPL M/s. IC Electricals Co.

PVT. Ltd.,

Office:

156, DSIDC, Okhla

Industrial Area, Phase –

1, New Delhi – 110020

Works:

E-94, Industrial Estate,

Bahdarabad, Haridwar,

Uttaranchal – 249402.

Ph. 011-

41613270,71,72,73

Mob.:

09319071511.

Fax: 011-41613273

Mob No.

09810881689 (Mr.

Sunil Verma)

e-mail:

icelctricals@redif

fmail.com

/suneel.icepl@g

mail.com /

sunviswa@rediff

mail.com

S OTH Regulated

Battery

Charger

12. ICL M/s. Intec Corp., Pho. 01702-38505 E-mail: S OTH Roof

Page No. Effective From Valid Till Master List No. Version No.

Page 56 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

Office:

Khasra No. 850/2, Mandi,

New Delhi – 110030

Works:-

F-89, Industrial Area,

Selaqui, Dehradun

(Uttarakhand) – 248197.

Fax: 011-6072549

Mob.

09810040890,

09418038505

intecselaqui@gm

ail.com /

intec@inteccorpo

ration.com /

[email protected]

om

mounted AC

Package

units for LHB

variant AC

coaches,

Double

Decker

RMPU.

13. IEL M/s. Integ electronics

Office:-

59, DSIDC Shed, Phase-

II, Scheme-III, Okhla

Industrial Area, New

delhi-110020

Works:-

59, DSIDC Shed, Phase-

II, Scheme-III, Okhla

Industrial Area, New

delhi-110020

Ph 011-26387855.

26386345,

26386048 fax

011-26388816

Mobile no.

9818617648 ,

09212169145

IK dhar

email id

[email protected] ,

[email protected]

m

S OTH Switch

Board

Cabinet for

EOG Type

Double

Decker

Coaches and

LHB EOG AC

coaches.

Switch

Board

Cabinet for

LHB AC

power car.

Page No. Effective From Valid Till Master List No. Version No.

Page 57 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

14. IL M/s. Instrumentation

Limited

Office:

7th Floor, Core-6, Scope

Complex, Lodhi Road,

New Delhi – 110 003

Works:

M/s Instrumentation

Limited, Jhalawar Road,

Kota- 324 005

Mobile:

09868100259

Email:

[email protected].

net.in

Switch

Board

Cabinet

15. ISPL M/s. International

Switchgear Private

Limited,

Office:

925-A, Industrial Area,

Phase-II, Chandigarh-

160002.

Works:

E-132-33-34, Industrial

Area, Phase VII, S.A.S.

Ph:0172-4559999

Fax. 0172-4559900

Email-

[email protected]

Variant of

Switch

Board

Cabinets of

LHB

coaches.

Page No. Effective From Valid Till Master List No. Version No.

Page 58 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

Nagar, Mohali (Punjab)

16. ISPL M/s. International

Switchgears Pvt. Ltd.

Office:

925-A, Industrial Area,

Phase-II, Chandigarh-160

002

Works:

E-132-33-34, Industrial

Area, Phase-VII, S.A.S

Nagar, Mohali (Punjab)

Mobile :

09872001929

Fax no. 0172-

4559900, 2652408.

E-mail:

[email protected]

m

Flexible

Polyamide

conduits

with its end

fittings and

accessories

(sizes:NW12,

NW17,

NW23,

NW29,NW36,

NW48)

17. KIL M/s. Kapsons Industries

Ltd.,

Office & Works:-

GT Road, Saranussi,

Jalandhar- 144027

Ph. 0181-5066326,

5066364, 2670900,

2670901, 2670902,

2670903

Fax 0181-5066328,

5066308, 2671901

------ OTH 3-phase

induction

motor for

RMPU

18. LEEL M/s. Lloyd Electric

&Engg. Ltd.,

Office:

011-6384182,

84,85,86

Fax: 011-632 1183

E-mail:

pmehra@lloyden

gg.com /

chandrashekhar

OTH Roof

mounted AC

Package

units for LHB

variant AC

Page No. Effective From Valid Till Master List No. Version No.

Page 59 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

B-10/1, Okhla Industrial

Area, Phase-II, New

Delhi-110020.

Works:

A-146, (B&C), RIICO Indl.

Area, Bhiwadi, Distt,

Alwar (Rajasthan) –301

019.

Fax: 01493-20543,

Ph. 01493-20724,

21348.

Mob. No.

09983337803

@lloydengg.com coaches,

Double

Decker

RMPU

19. MVEPL M/s. M.V. Electrosystems

Pvt. Ltd.,

Office:

Plot No. 78, PragatiVihar,

Industrial Area, Sector-

59, Faridabad-121004

(Haryana)

Work:

Plot No. 72, PragatiVihar,

Industrial Area, Sector

59, Faridabad-121004

(Haryana)

Ph: 0129-2307182

Fax: 0129-2307167

ContctPerson:Mo

hitVohra

Mobile No.

:09810804481

E-mail:

mohit@mvelectro

systems.com

Flexible

Polyamide

conduits

with its end

fittings and

accessories(

sizes: NW10,

NW12,

NW17, NW

23, NW 29,

NW 36, NW

48)

Page No. Effective From Valid Till Master List No. Version No.

Page 60 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

20. NECSCL M/s. NEC Switchgears

and Controls,

Office & Works:-

E-254, Industrial Area,

Phase 8-B, Mohali- 160

071 (Punjab) India

Mobile:

09646020016

Fax no. 0172-

4644144

E-mail-

info@necswitchg

ears.com ,

[email protected]

m

Switch

Board

Cabinet

21. PEL M/s. Prime Electronics,

Plot No.-220, Phase-V,

EHTP, Sector-56, Kundli,

Sonepat-131028.

Contact person-

MohitVohra

Mob.09810804481

Email :

mohit@primeelec

tronics.co.in

- - 500A 750V

Inter

Vehicular

(IV) Coupler

22. RSISPL M/s. RSI Switchgear Pvt.

Ltd.

Office:-

#217, 2nd Floor, 138,

B.R.B.B. Road (canning

street), Kolkata

Works:-

F-252 &

253,RIICO,Industrial

Area,Kehrani-301019

Fax no. 033-

22431311.

Mob.08875009800.

Email :

rsiggn@rsiswitch

gear.co.in.

Switch

Board

Cabinet

Page No. Effective From Valid Till Master List No. Version No.

Page 61 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

(Bhiwadi

Extension),Distt.-Alwar

(Rajasthan)

23. SECL M/s. Star Electric

Company,

Office & Works:-

30/38 Guru Govind Singh

Nagar, Back side Appollo

Hospital, G.T. Road

Ludhiana- 141003 Punjab

Ph: 0161-2542767,

Fax: 0161-2542768

e-mail:

info@stecoindia.

com

415 V, 3-

Phase

induction

Motor for

roof

mounted AC

package

units.

24. SL M/s. Stesalit Ltd.,

Office:

Park Plaza (North), 71

Park Street, Kolkata –

700016

Works:

Plot No. 17, HPSIDC

Baddi, PO: Baddi, Distt:

Solan (HP) – 173205

Plot no.1 , SurajMajra,

LabanaIndustrials area

033-

22654984,85,86,87

FAX 033-22495305

mobile no.

9830065962

SK Gupta CEO

Ph 01795-246906

Fax 01795-244236

Mob.9836065234

Email id

skgmarketing@g

mail.com

Switch

Board

Cabinet

Page No. Effective From Valid Till Master List No. Version No.

Page 62 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

Baddi (HP)-173205

25. SRIPL M/s. Sidwal Refrigeration

Industries Private Ltd.,

Office:

108-A, Madangir, New

Delhi-110062

Works:

Plot No. 23, Sector – 6,

Faridabad, Haryana –

121006.

Ph: 011-

26057222,4164970

0, 0129-2241240,

2242060

Fax: 011-

26036433,

41649706, 0129-

2240078 Mob.

9810184569

9818898151 (w)

E-mail:

sidwal@airtelmail

.in /

[email protected]

S OTH Roof

mounted AC

Package

units for LHB

variant AC

coaches and

double

decker

RMPU,

Microproces

sor

controller for

roof

mounted AC

package unit

for LHB

coaches and

double

decker

coaches

26. TCSPL M/s. Trinitron Control

Systems Pvt. Ltd.,

Office:

Mobile :

09811924388

Fax no. : 0120-

E-mail:

trinitron_8@rediff

mail.com

Switch

Board

Cabinet

Page No. Effective From Valid Till Master List No. Version No.

Page 63 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

A-42, Sector-8, Uttar

Pradesh-201301

Works:

82-83-84, Toy City,

Ecotech III, G. Noida, UP-

201 308

2424125.

27. TEPL M/s. Transtel

Engineering (P) Ltd

Office & Works:

Vill: DhakruMajra, Near,

Auro Dying Mill, P.O.:

Baddi, Distt. : Solan, H.P

: 173 205

Ph. No. 01795-

656851

Tele/Fax 01795-

244270

Mobile :

09218584861.

E-mail:

transtelbaddi@g

mail.com

Switch

Board

Cabinet

28. TEPL

(HPSIDC)

M/s. Transtel

Engineering (P) LTD.

Office & Works:-

Unit-II, Plot No. 154,

HPSIDC, Baddi, Distt.

Solan(H.P.)-173205

Ph.-01795-656851

Ph./Fax-01795-

244270

Email:

transtelbaddi@g

mail.com

Regulated

Battery

Charger

29. TPPL M/s. TirupatiPlastomatics Ph. 0141-2331030, Email: Flexible

Page No. Effective From Valid Till Master List No. Version No.

Page 64 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Owners

hip

Equipment Remarks

1 2 3 4 5 6 7 8 9

Pvt. Ltd., Office & Works: F-543, (Unit-II), Road No. 6D, Vishwarkarma Industrial Area, Jaipur-302013, Rajasthan.

Fax 0140-2331808,

2260073

[email protected]

Polyamide

conduits

with its end

fittings and

accessories.

C. SOUTHERN REGION

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Ownershi

p

Equipment Remarks

1 2 3 4 5 6 7 8 9

30. AESPL M/s. Areca Embedded

System Pvt. Ltd.

Office:-

Plot No. 54/S, Anupuram

Colony, ECIL, Hyderabad

- 500051

Works:

Plot 5B, Survey No. 184 &

185, Phase –V, IDA,

CheralapallyRangaRreddy

district, Hyderabad (AP) -

Ph: 040-65744131,

27263366,67, 68

Fax 040-27131444,

27263369,

27144460

Mob 9346627142

(Mrs. GV Kumari)

E-mail:

[email protected]/

[email protected] /

shaik.hameed786

@gmail.com

S OTH Microproce

ssor

controller

for RMPU

of LHB and

Double

decker

coaches

Page No. Effective From Valid Till Master List No. Version No.

Page 65 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Ownershi

p

Equipment Remarks

1 2 3 4 5 6 7 8 9

500051

31. ARBL M/s. Amara Raja Batteries

Ltd.,

Office:-

Renigunta, Cuddapah

Road, Karkambadi-

517520, Tirupati (A.P.).

Works 1:-

Renigunta, Cuddapah

Road, Karkambadi-

517520, Tirupati (A.P.).

Work II

NunegundlaPalli,

BangarupalyamMandal,

Chittoor, District, AP –

517416

Fax No. 0877-

2285600

Ph No. 0877-

2265000 / 0857-

2280100.

E-mail:

[email protected]

o.in

OTH OTH

All type of

VRLA

batteries

120Ah,

12V70Ah

VRLA

battery.

32. HBLPSL M/s. HBL Power System

Ltd.,

Office:-

8-2-601, Road No. 10,

Ph. 08922-

2258159, 179, 171-

175

Fax 0892-

E-mail: [email protected]

OTH OTH

Page No. Effective From Valid Till Master List No. Version No.

Page 66 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Ownershi

p

Equipment Remarks

1 2 3 4 5 6 7 8 9

Banjara Hills, Hyderabad-

500 034

Work 1:-

Survey No. 123 to 126 &

138(P) to 144(P), Village:

Kandivalsa, Pusapatirega

(Mondal), KaniMetta,

Vizianagaram – 535204

(Andhra Pradesh).

Work 2:-

Survey No. 64 to 67 & 77

to 81,Nandigaon Village,

Kothur (Mandal),

Mahaboob Nagar, Distt-

509 223 Telengana (INDIA)

2258156/161

Head Office

Ph. 040-23355575,

23355085

Ph. 08542-

205213/215

Fax 08542-236204

HO Fax No. 040-

23355048

Ph. 040-

23355575,

23355085

Fax No. 08548-

240473/ 240479

All type of

VRLA

70Ah,

120Ah,

650Ah

VRLA only

33. KEAECL M/s. Kerala Electricals &

Allied Engg. Co. Ltd.,

Office:-

7th Floor, KSHB Office

Mobile:

09495681118.

Ph.: 0474-

2522215/16.

Fax: 0474-

E-mail:

[email protected]

n /

[email protected]

M OTH

ERRU

Page No. Effective From Valid Till Master List No. Version No.

Page 67 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Ownershi

p

Equipment Remarks

1 2 3 4 5 6 7 8 9

Complex,

Panampilly Nagar, Cochin-

682 026

Works:-

Post Bag No. 8,

Kundra, Kollam-691 501

(Kerala)

2522514.

34. MEPL M/s. Microtex Energy Pvt.

Ltd.

Office & Works:-

No. 42 & 43, II Main, II

Phase, Pennya Industrial

Area, Bangalore-560058

Ph. 080-28397243,

080-28394417

E-mail:

rkgovindan@gma

il.com

OTH OTH VRLA

Battery

35. SBPL M/s. Southern Batteries

Pvt. Ltd.,

Office:-

No. 328, Bommasandra,

Jigani Link road Industrial

Area, JiganiAnekalTaluk

Bangalore – 560099.

91-080-78-34446

E-mail:

arvindsamant@s

outhernbatteries.

com

S OTH

VRLA

Page No. Effective From Valid Till Master List No. Version No.

Page 68 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Ownershi

p

Equipment Remarks

1 2 3 4 5 6 7 8 9

Work:-

Unit-1, Plot No. 30, KIADB

Industrial Area,

Bommasandra, Bangalore

- 560099

36. SEIL M/s. Standards Electrical

Industries,

Office & Works:-

10, Jayshree Nagar

Housing Unit, Singanallur,

Coimbatore – 641005

(Tamilnadu)

3-phase

induction

motor for

RMPU

37. TIPL M/s. Trolex India Private

Ltd.,

Plot#88-B,Electronic

City,Hosur

Road,Bangalore-560100

Ph. 080-28520008,

M.09448514123.

e-mail:

mary@vishwagro

up.co.in

Switch

Board

Cabinet for

LHB EOG

AC

coaches

38. UCL M/s. Universal Controls,

Office:

42, Electronics Complex

(Extn) Kushaiguda,

Ph : 040-27144794

Fax: 040-27120187

91-9246522255

e-mail:

info@universal-

controls.com

/

S OTH Microproce

ssor

Controller

for RMPU

of LHB and

Page No. Effective From Valid Till Master List No. Version No.

Page 69 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Ownershi

p

Equipment Remarks

1 2 3 4 5 6 7 8 9

Hyderabad-500062.

Works:

Plot no. A-7/1, 3rd floor,

Electronic complex,

Kushaiguda, Hyderabad-

500062.

[email protected]

om/naveen@sirn

aveen.com

Double

Decker AC

coaches

D. WESTERN REGION

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Ownershi

p

Equipment Remarks

1 2 3 4 5 6 7 8 9

39. CGL M/s. Crompton Greaves

Ltd.,

Office & Works:-

A-6/2, Ahmednagar –

414111 Maharashtra

(India).

Phone No. 0241-

2776160/62

Fax: 0241-

2777508.

e-mail:

sivasankar.rama

nathan@cgglobal

.com

500 kVA

Alternator

For

Power

Car

40. CGL

(Pithampur)

M/s. Crompton Greaves

Ltd.,

Phone No. 022-

24237777

----- 25 KVA

Underslung

Inverter

Page No. Effective From Valid Till Master List No. Version No.

Page 70 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Ownershi

p

Equipment Remarks

1 2 3 4 5 6 7 8 9

Office:-

CG House, 6th Floor, Dr

Annie Besant Road, Worli,

Mumbai-400 030

Works:-

Railway Signaling

division, 11-B, Industrial

Area No.1, Pithampur- 454

775, Dist. Dhar, M.P.

Fax: 022-24237733

Phone No.

07292410 000

Fax: 07292 253211

41. CIL M/s.Cummins India

Limited

Office:-

Cummins India office

campus, Survey no. 21,

near

BhartiVidhyapeethenglish

medium primary school,

Balewadi, Pune – 411045

(Maharastra).

Works:-

Cummins India Limited,

Kothrud, Pune – 411038

Phone No. 020-

67068308, Fax No.

020-25381591

Contact No.

Mobile No.

09881741997

Phone No. 020-

30233740,

Fax No. 020-

25381591.

e-mail:

janamjay.singh@

cummins.com

*and #

Approv

ed for

M/s.

KEC &

M/s.

BHEL-

EML

$

Approv

ed for

Cummi

ns

diesel

engine

Page No. Effective From Valid Till Master List No. Version No.

Page 71 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Ownershi

p

Equipment Remarks

1 2 3 4 5 6 7 8 9

(Maharastra). with

M/s.

KEC &

M/s.

BHEL-

EML

42. DGSSSL M/s. Deev Gen Set Sales & Services,

Office:-

359, 3rd floor, Dena bank building, Bhola (Shiva Market, Pitampura, Delhi-110034.

Works:-

Survey No. 2771/1/3, Demini Road, village Dadra, Silvasa-396230 (Dadra & Nagar Haweli).

Phone & Fax No. 011-45073739, Mob No. 09818967385 (Mr. Sanjay Mehta Delhi).

Phone & Fax No. 0260-2420172, Mob No. 09824158765 (Mr. Dinesh Gujrati)

E-mail: [email protected]/ [email protected]

E-mail:

deevgensetsilvas

[email protected]

500 KVA

Diesel –

Alternator

Set For

Power Car

43. HRL M/s. Hind Rectifier Ltd.,

Office : -

P.B.No. 17303, Lake Road,

Bhandup(W), Mumbai-

Fax 0172-4644144.

e-mail:

[email protected]

om

Switch

Board

Cabinet for

LHB EOG

AC

Page No. Effective From Valid Till Master List No. Version No.

Page 72 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No. Abbreviatio

n

Name and Address of the

firm

Tel & Fax No. email Cate

gory

Ownershi

p

Equipment Remarks

1 2 3 4 5 6 7 8 9

400078

Work : -

Plot No. 110/111,E-16

Road,MIDC,Satpur,

Nashik-422007

(Maharashtra)

coaches

44. SIL M/s. S. Internationals Ltd.

B / 14, Creative Indl.

Estate, 72, N.N. Joshi

Marg, Chinchpokli (West),

Mumbai - 400 011.

Ph: 011-

43474200/3243907

1

Fax: 011-

23096290

ZS

Coupling

400 A 750 V

45. ULOPPL M/s. United Lead Oxide

Product Pvt. Ltd.,

Office & Works:-

Plot No. 216, Kundaim

Industrial Estate,

Kundaim, Goa-403 115

Ph. 0832-2395534

Email:

ravindra@jumbo

batteryindia.com

S OTH TL Battery

*************

Page No. Effective From Valid Till Master List No. Version No.

Page 73 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

PART-C

CHAPTER VI- EQUIPMENT AND CONDUCTORS FOR 25 kV AC TRACTION INSTALLATION

S. No. Equipment Current Specification /Drawing No. Vendors for Developmental

Order

Annual Production Capacity

Remarks

1 2 3 4 5 6

1.0 TRANSFORMERS AND OTHER TSS EQUIPMENT

1.1 TRACTION POWER TRANSFORMER 1.1.0

(a) 21.6/30.24 MVA, 50 Hz, Single Phase, ONAN/ONAF, Traction Power Transformer 220/27 kV.

ETI/PSI/118(10/1993) with A/C Slip No. 1 (May, 1994), Slip No. 2 (Jan,1996), Slip No.3 (Oct,1997), Slip No 4 (Jan,2000), Slip No. 5 (April,2000), Slip No 6 and 7 (June,2001), Slip No 8 (July,2003), Slip No. 9 (Jan,2008), Slip No. 10 (August,2012) and Slip No. 11 (Oct, 2016)

BHEL(Jhansi) ((BHEL - 25),

1.1.0 (b)

21.6 /30.24 MVA, 50 Hz, Single Phase, ONAN /ONAF, Traction Power Transformer 132/27 kV

ETI/PSI/118 (10/1993) with A/C Slip No. 1 (May, 1994), Slip No. 2 (Jan,1996), Slip No. 3 (Oct,1997) , Slip No 4 (Jan,2000), Slip No 5 (April, 2000), Slip No 6 and 7 (June, 2001), Slip No 8 (July, 2003), Slip No. 9 (Jan,2008), Slip No. 10 (August,2012) and Slip No. 11 (Oct, 2016).

AVAL ( Thane)

1.1.0 (c)

21.6/30.24 MVA, 50 Hz, Single Phase, ONAN/ONAF, Traction Power Transformer

110/27 kV

ETI/PSI/118 (10/1993) with A/C Slip No. 1 (May, 1994), Slip No. 2 (Jan,1996), Slip No. 3 (Oct,1997) , Slip No 4 (Jan,2000), Slip No 5 (April, 2000), Slip No 6 and 7 (June, 2001), Slip No 8 (Jul,2003), Slip No. 9 (Jan,2008), Slip No. 10 (August,2012) and Slip No. 11 (Oct, 2016)

1.1.0 (d)

21.6/30.24 MVA, 50 Hz, Single Phase, ONAN/ONAF, Traction Power Transformer

66/27 kV

TI/PSI/118 (10/1993) With A/C Slip No. 1 (May,

1994), Slip No. 2 (Jan,1996), Slip No. 3 (Oct,1997)

, Slip No 4 (Jan,2000), Slip No 5 (April, 2000), Slip

No 6 and 7 (June,2001), Slip No 8 (July,2003), Slip

No. 9 (Jan,2008), Slip No. 10 (August,2012) and

Slip No. 11 (Oct, 2016)

CGL (Mumbai) EMCO (Thane)

(CGL- 20), (EMCO - 10),

1.1.1 (a)

21.6 MVA, 50 Hz, Single Phase, ONAN, Traction Power Transformer

100/27 kV

ETI/PSI/163 (04/1997) with A & C Slip No.1 (Nov, 1998), Slip No. 2 (Jan, 2000), Slip No. 3 (April, 2000) & Slip No. 4 (Oct, 2016)

EMCO (Thane) (EMCO - 10),

1.1.1 (b)

21.6 MVA, 50 Hz, Single Phase, ONAN, Traction Power Transformer 22/27 kV

ETI/PSI/163 (04/1997) with A& C Slip No.1 (Nov, 1998) & Slip No. 2 (Jan, 2000), Slip No. 3 (April, 2000) & Slip No. 4 (Oct, 2016).

EMCO (Thane) (EMCO - 10),

Page No. Effective From Valid Till Master List No. Version No.

Page 74 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No. Equipment Current Specification /Drawing No. Vendors for Developmental

Order

Annual Production Capacity

Remarks

1 2 3 4 5 6

1.1.2 30 MVA, 50 Hz, Single Phase, ONAN, Traction Power Transformer with On Load Tap Changer (110/27kV)

TI/SPC/PSI/30TRN/1050 with A & C Slip No.1

(Oct, 2016)

ALSTOM(N) ALSTOM(VADODARA)

1.1.3 (a)

30 / 42 MVA, 50 Hz, Single Phase, ONAN/ONAF Traction Power Transformer (220/27 KV)

TI/SPC/PSI/30TRN/2070 with A & C Slip No.1

(Oct, 2016)

1.1.3 (b)

30 /42 MVA, 50 Hz, Single Phase, ONAN/ONAF, Traction Power Transformer (132/27 KV)

TI/SPC/PSI/30TRN/2070 with A & C Slip No.1

(Oct, 2016)

ALSTOM (Naini) ALSTOM (Vadodara) AVAL(Thane)

1.1.3 (c)

30 / 42 MVA, 50 Hz, Single Phase, ONAN/ONAF, Traction Power Transformer (110/27 KV)

TI/SPC/PSI/30TRN/2070 with A & C Slip No.1

(Oct, 2016)

TELK(Kerla) (TELK – 10)

1.1.3 (d)

30 / 42 MVA, 50 Hz, Single Phase, ONAN/ONAF, Traction Power Transformer (66/27 KV)

TI/SPC/PSI/30TRN/2070 with A & C Slip No.1

(Oct, 2016)

NOTE: If a Vendor not approved for a particular Specification, A & C Slip is and given an order, the Vendor shall get the first Prototype, implementing such A & C Slip, for which the Vendor was hitherto not approved, duly approved by RDSO. These vendors are also suitable for Repairs of Traction Power Transformer in reference to Railway Board’s Letter no. 2005/RE/141/1 dated 17.05.2005.

1.2. INSULATING OIL

1.2.1 Inhibited Mineral Insulating

Oil

IS: 12463(1988) & Railways requirements as per

RDSO letter No. TI/PSI /INSOIL/POLICY/07 dated 27.02.2007 &TI/PSI/INSOIL/POLICY/08 dated 06.02.2008 and

TI/PSI/TRNPWR/POLICY/16/01 dated 28.10.2016.

BHARAT(Mumbai)

Columbia(Silvasa) HPCL (Mumbai) IOC (Silvasa)

(12000 KL)

1.2.2 Inhibited Mineral Insulating Oil , Oil for 3 Phase Locomotives 1.2.2

(a) Transformer Oil IEC: 60296-2003 and CLW Spec.No.

CLW/ES/3/0172 (Latest and RDSO requirement) and RDSO letter No. TI/PSI/TRNPWR/POLICY/16/01 dated 28.10.2016.

RAJ PETRO SPECIALITIS (Chennai)

RAJ PETRO SPECIALITIS (Silvasa)

GANDHAR (Raigad)

Gandhar (2000 KL)

1.2.2 (b)

Converter Oil IEC: 60296-2003 and CLW Spec.No. CLW/ES/3/0172 (Latest and RDSO requirement) and RDSO letter No.

Page No. Effective From Valid Till Master List No. Version No.

Page 75 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No. Equipment Current Specification /Drawing No. Vendors for Developmental

Order

Annual Production Capacity

Remarks

1 2 3 4 5 6

TI/PSI/TRNPWR/POLICY/16/01 dated 28.10.2016.

2.0 SWITCH GEAR

2.1 High Voltage Circuit Breaker

2.1 (a)

220 kV SF6 Circuit Breaker (Double Pole & Triple Pole)

TI/SPC/PSI/HVCB/0120 (June,2014) Rev.0 with A&C Slip No.1& 2 (Oct. 2016)

CGL (Nasik), (Type 120 – SFM- 32 B Spring- Spring Operating Mechanism)

(CGL-200)

2.1 (b)

132kV SF6 Circuit Breaker (Double Pole & Triple Pole)

TI/SPC/PSI/HVCB/0120 (June,2014) Rev.0 with A&C Slip No.1& 2 (Oct. 2016)

2.2 25kV CIRCUIT BREAKER

(a) Single Pole Vacuum Circuit Breaker

TI/SPC/PSI/LVCBIN/0120 (Dec,2013) Ver.0. with A&C Slip No.1 (Oct. 2016)

BHEL, Bhopal. (Type PVTB Spring-Spring Operating Mechanism),

(BHEL- 200)

2.3 25 KV INTERRUPTER

(a) 25 kV Single Pole Vacuum Interrupter

TI/SPC/PSI/LVCBIN/0120 (Dec,2013) Ver.0. with A&C Slip No.1 (Oct. 2016)

2.4 Motorised Isolator

(a) 25 kV, 1250 A, Type –I (A&B) ,1600 A, (Type –II), Single Pole /Double Pole Motorised Isolator

TI/SPC/PSI/ISOLTR/1060 With A&C Slip No.01& 2 (Oct. 2016)

*Electrolites (Power) Pvt. Ltd, Jaipur

*Switchgears &Structurals (India) Pvt.Ltd., Hyderabad.

* Prototype as per latest specification to be conducted.

3.0 HDGC COPPER CONTACT WIRE

(a) Joint less Grooved Copper Contact Wire, 107 mm2, made out of Continuous Cast Copper Wire Rods.

ETI/OHE/76 (06/97) With A & C Slip No. 1, 3, 4, 5, 6, 7, 8 & 9.

(b) Joint less Grooved Copper Contact Wire, 150 mm2, made out of Continuous Cast Copper Wire Rods.

ETI/OHE/76 (06/97) With A & C Slip No. 1, 3, 4, 5, 6 7, 8 & 9.

SSEPL(Brand Name

“MITUSHI”)

(4800MT)

(c) Joint less Grooved Copper Contact Wire, 193 mm2, made out of Continuous Cast Copper Wire Rods.

ETI/OHE/76 (06/97) With A & C Slip No. 1, 3, 4, 5, 6 7, 8 & 9.

3.1 Continuous Cast Copper (CCC) Wire Rod (a) Continuous Cast Copper (CCC)

Wire Rod (Manufactured by South Wire Process) for manufacturing 107 mm2 joint less Hard Drawn Grooved

ETI/OHE/65 (08/87) with A & C Slip No. 1 to 4. ETI/OHE/76 (06/97) with A & C Slip No. 1, 3, 4, 5, 6 7, 8 & 9.

Page No. Effective From Valid Till Master List No. Version No.

Page 76 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No. Equipment Current Specification /Drawing No. Vendors for Developmental

Order

Annual Production Capacity

Remarks

1 2 3 4 5 6

Copper Contact Wire (b) Continuous Cast Copper (CCC)

Wire Rod(Manufactured by South Wire Process) for manufacturing 150 mm2 joint less Hard Drawn Grooved Copper Contact Wire

ETI/OHE/65 (08/87) with A & C Slip No. 1 to 4. ETI/OHE/76 (06/97) with A & C Slip No. 1, 3, 4, 5, 6 7, 8 & 9.

(c) Continuous Cast Copper (CCC) Wire Rod(Manufactured by South Wire Process) for manufacturing 193 mm2 joint less Hard Drawn Grooved Copper Contact Wire

ETI/OHE/65 (08/87) with A & C Slip No. 1 to 4. ETI/OHE/76 (06/97) with A & C Slip No. 1, 3, 4, 5, 6 7, 8 & 9.

4.0 CATENARY WIRE

(a) Un-insulated Cadmium Copper Catenary Wire 65 mm2 (19/2. 10 mm)

ETI/OHE/50 (06/97) with A & C Slip No. 1 to 5

(b) Insulated Cadmium Copper Catenary wire 65 mm2

(19/2.10 mm)

TI/SPC/OHE/INSCAT/0000 with A & C Slip No. 1& 2

(C ) Un-insulated Cadmium Copper Catenary Wire 125 mm2 (37/2. 10 mm)

ETI/OHE/50 (06/97) with A & C Slip No. 1 to 5 VEEKAY (3000 MT)

5.0. SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA) 5.1 SCADA System Complete. TI/SPC/RCC/SCADA/0130 (Rev.2) with A&C Slip

No. 1

CMC* ITI (B) *

*Revalidation as per Revised Specification is pending.e.

6.0 PANEL & RELAY

6.1 CONTROL & RELAY PANEL

(a) Control & Relay Panel, Incorporating Numerical Type Protective Relays, for 25 kV AC Traction.

TI/SPC/PSI/PROTCT/6071 with A&C Slip No. 1

(b) Control and Relay Panel, incorporating Numerical Type Protective Relays for Mumbai Suburban area

TI/SPC/PSI/PROTCT/4050( 10/2005) with A&C Slip No. 1

ALIND(T) ALIND-50Sets),

6.2 RELAYS FOR 25 KV AC TRACTION

6.2.1 NUMERICAL TYPE TRACTION TRANSFORMER PROTECTION RELAYS

(a) Over Current & Restricted Earth Fault Relay

TI/SPC/PSI/PROTCT/6071 with A&C Slip No. 1

Page No. Effective From Valid Till Master List No. Version No.

Page 77 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No. Equipment Current Specification /Drawing No. Vendors for Developmental

Order

Annual Production Capacity

Remarks

1 2 3 4 5 6

(b) Differential Protection Relay TI/SPC/PSI/PROTCT/6071 with A&C Slip No. 1

6.2.2 NUMERICAL TYPE RELAYS FOR 25 KV FEEDER PROTECTION (a) Feeder Protection Module,

Comprising DPR,OCR,WPC,PTFF &Auto Reclosure

TI/SPC/PSI/PROTCT/5070 (Rev.1) with A&C Slip No. 1

(b) Delta-I Relay TI/SPC/PSI/PROTCT/1982 with A & C Slip No.1 & 2

(c) Panto Flash Over Protection Relay

TI/SPC/PSI/PROTCT/2983 with A&C Slip No. 1 ASHIDA (Type:APFO/1)

(Logic 1)

(ASHIDA - 1000)

6.2.3 OTHER RELAYS

(a) Master Trip Relay TI/SPC/PSI/PROTCT/6071 with A&C Slip No. 1

(b) Inter Trip Relay TI/SPC/PSI/PROTCT/6071 with A&C Slip No. 1

(c) Voltage Operated Aux. Relay TI/SPC/PSI/PROTCT/6071 with A&C Slip No. 1 ASHIDA (Type:AVAJH43) ALIND (T) (Type:AEIH50)

(ALIND - 1000), (ASHIDA - 1000)

(d) Numerical AC & DC

Monitoring Relay TI/SPC/PSI/PROTCT/6071 with A&C Slip No. 1 Also permitted for 2 x

25 kV Traction as per

RDSO Specification No.

TI/SPC/PSI/PROTCT/710

0 (07/2012) with A&C Slip No. 1

6.3 NUMERICAL TYPE RELAYS FOR MUMBAI SUBURBAN AREA

(a) Integrated Feeder Protection Relay

TI/SPC/PSI/PROTCT/4050(10/2005) with A&C Slip No. 1

ALIND (T) (Type:ANZ 114)

(ALIND - 1000),

(b) Vectorial Delta-I Relay TI/SPC/PSI/PROTCT/4050(10/2005) with A&C Slip No. 1

ALIND (T) (Type:AVDI-11C)(AN SERIES)

(ALIND - 1000),

(c) Panto Flashover Protection Relay

TI/SPC/PSI/PROTCT/4050(10/2005) with A&C Slip No. 1

ALIND (T) (Type:APF401M) (AN

SERIES)

(ALIND - 1000),

(d) Over Current & Restricted Earth Fault Transformer Protection Relay

TI/SPC/PSI/PROTCT/4050(10/2005) with A&C Slip No. 1

ALIND(T)

(Type:ATP214 HV/LV) (AN

SERIES)

(ALIND - 1000),

(e) Transformer Differential Protection Relay

TI/SPC/PSI/PROTCT/4050(10/2005) with A&C Slip No. 1

ALIND(T) (Type:ATD12) (AN SERIES)

(ALIND - 1000),

(f) Low Impedance Bus-Bar Differential Protection Relay

TI/SPC/PSI/PROTCT/4050(10/2005) with A&C Slip No. 1

ALIND(T) (Type: ABD301) (AN SERIES)

(ALIND - 1000),

(g) High Impedance Bus-Bar Differential Protection Relay

TI/SPC/PSI/PROTCT/4050(10/2005) with A&C Slip No. 1

ALIND(T)

(Type:ABD101) (AN SERIES)

(ALIND - 1000),

(h) Definite Time Over Current Relay

TI/SPC/PSI/PROTCT/4050(10/2005) with A&C Slip No. 1

ALIND(T) (Type:ADC101)(AN SERIES)

(ALIND - 1000),

Page No. Effective From Valid Till Master List No. Version No.

Page 78 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No. Equipment Current Specification /Drawing No. Vendors for Developmental

Order

Annual Production Capacity

Remarks

1 2 3 4 5 6

(i) Reverse Power Protection Relay TI/SPC/PSI/PROTCT/4050(10/2005) with A&C Slip No. 1

ALIND(T) (Type:ARP101)(AN SERIES)

(ALIND - 1000),

(j) Synchronous Check Relay TI/SPC/PSI/PROTCT/4050 (10/2005) with A&C Slip No. 1

ALIND(T) Type:ASC202 (AN SERIES)

(ALIND - 1000),

(k) DC Monitoring / Supervision Relay

TI/SPC/PSI/PROTCT/4050 (10/2005) with A&C Slip No. 1

ALIND(T) (Type:ANSM 022)

(ALIND - 1000),

6.4 NUMERICAL TYPE RELAYS FOR OHE PROTECTION WITH PARALLEL OPERATION OF TRACTION TRANSFORMERS

(a) Integrated Feeder Protection Relay

TI/IN/0017 & TI/SPC/PSI/PROTCT/4050(10/2005) with A&C Slip No. 1

ASHIDA (Type:ADR219B)

(ASHIDA - 1000)

(b) Over Current & Restricted Earth Fault Transformer Protection Relay

TI/IN/0017 & TI/SPC/PSI/PROTCT/4050(10/2005) with A&C Slip No. 1

ASHIDA (Type:ADR221B)

(ASHIDA - 1000)

7.0 SHUNT CAPACITOR

7.1 Capacitor (Conventional Type)

TI/SPC/PSI/FC&SR/0100 with A&C Slip No. 1

(Oct 2016)

Energi Capacitors Pvt. Ltd. (Energi)

EPCOS(N)

7.2 Series Reactor for Capacitor Bank Low loss

TI/SPC/PSI/FC&SR/0100 with A&C Slip No. 1

(Oct 2016)

7.3 Control and Relay Panel for Capacitor Bank

TI/SPC/PSI/PROTCT/6071 with A&C Slip No. 1

7.4 Numerical Type Relays for 25 kV Shunt Capacitor Bank (a) Under / Over Voltage

Protection Relays

TI/SPC/PSI/PROTCT/6071 with A&C Slip No. 1

(b) Over Current & Unbalance Current Relay

TI/SPC/PSI/PROTCT/6071 with A&C Slip No. 1

7.5 Dynamic Reactive Power Compensation Equipment

TI/SPC/PSI/DRPC/0050 with A&C Slip No. 1 (Oct 2016)

ABB (B) DUBAS SHREEM

Required quantity insignificant in comparison to capacities of firms, so capacities are not applicable

8.0 BUSHINGS, POST & OPERATING ROD INSULATORS

8.1 BUSHINGS

(a) 245 kV OIP Condenser Bushing for Main

Transformer

IS:2099-1986 IS:12676-1989 IEC 137 -1995 & RDSO letter No.

TI/PSI/TRNPWR/POLICY/16/01 dated 28.10.2016.

(b) 145 kV OIP Condenser IS:2099-1986

Page No. Effective From Valid Till Master List No. Version No.

Page 79 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No. Equipment Current Specification /Drawing No. Vendors for Developmental

Order

Annual Production Capacity

Remarks

1 2 3 4 5 6

Bushing for Main

Transformer

IS:12676-1989 IEC 137 -1995 & RDSO letter No.

TI/PSI/TRNPWR/POLICY/16/01 dated 28.10.2016.

(c) 52 kV 2000A OIP Condenser Bushing for Main Transformer

IS:2099-1986 IS:12676-1989 IEC 137 -1995 & RDSO letter No.

TI/PSI/TRNPWR/POLICY/16/01 dated 28.10.2016.

YASH (Drg.No.CBSO 52D OOH Rev. 0)

1500 Nos.

(d) 52 kV 3150A OIP Condenser Bushing for Main Transformer

IS:2099-1986 IS:12676-1989 IEC 137 -1995 & RDSO letter No.

TI/PSI/TRNPWR/POLICY/16/01 dated 28.10.2016.

ALSTOM (H) (Drg.No.100-3A-800Rev.04)

YASH (Drg.No.CBSO 52D OOH Rev. 0)

1500 Nos.

9.0 COMPOSITE INSULATORS FOR OHE AND ASSOCIATED FITTINGS

9.1 STAY ARM INSULATOR

(a) Composite Stay Arm Insulator (1050mm CD)

TI/SPC/OHE/INSCOM/1071 (Rev-01) ABI * Asiatic* TG* YPIL*

PRITHVI*

*Revalidation as per

Revised Specification is

pending.

(b) Composite Stay Arm Insulator (Very heavy polluted) (1600mm CD)

TI/SPC/OHE/INSCOM/ 1071 (Rev-01) DECCAN* GIL*

*Revalidation as per

Revised Specification is

pending.

9.2 BRACKET INSULATORS

(a) Composite Bracket Insulator (1050 mm CD)

TI/SPC/OHE/INSCOM/ 1071 (Rev-01) ABI* BHEL* TG* YPIL* PRITHVI*

*Revalidation as per

Revised Specification is

pending.

(b) Composite Bracket Insulator (Very heavy polluted) (1600mm CD)

TI/SPC/OHE/INSCOM/ 1071 (Rev-01) DECCAN* GIL*

*Revalidation as per

Revised Specification is

pending.

9.3 9-TONNE INSULATORS

(a) Composite 9 Tonne Insulator (Polluted zone)(1050mm CD)

TI/SPC/OHE/INSCOM/ 1071 (Rev-01) ABI* TG* YPIL* PRITHVI*

*Revalidation as per

Revised Specification is

pending.

(b) Composite 9 Tonne Insulator (Very Heavy Polluted)

(1600mm CD)

TI/SPC/OHE/INSCOM/ 1071 (Rev-01) DECCAN* GIL*

*Revalidation as per

Revised Specification is

pending.

Page No. Effective From Valid Till Master List No. Version No.

Page 80 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No. Equipment Current Specification /Drawing No. Vendors for Developmental

Order

Annual Production Capacity

Remarks

1 2 3 4 5 6

9.4 SECTIONING INSULATORS

(a) Light Weight Section Insulators Assembly

TI/SPC/OHE/LWTSI/0060 (Rev.1) with A&C Slip No.1

GALLAND Approved for following combination of conductor S.No

Catenary Wire Grooved copper Contact wire

1 19/2.10 mm, 65 mm2 Cadmium copper

107 mm2

2 19/2.10 mm, 65 mm2 Cadmium copper

150 mm2

3 19/2.79 mm, 65 mm2 Aluminium Alloy

107 mm2

4 37/2.92 mm, 242 mm2 Cadmium copper

193 mm2

(b) Section Insulator Assembly (Without Section Insulator)

ETI/OHE/27(08/1984) with A&C Slip No. 1 & 2

Economics Electricals KEW KHATRI

(c) 25 kV Composite section Insulator (1050 mm CD)

TI/SPC/OHE/INSCOM/ 1071 (Rev-01) DECCAN* *Revalidation as per

Revised Specification is

pending.

10.0 REGULATING EQUIPMENT (ATD) -THREE PULLEY TYPE AND STAINLESS STEEL WIRE ROPE

10.1 Regulating Equipment (ATD) -Three Pulley Type with Modified Pulley Groove (3:1 Ratio) (with use of NBC Ball Bearing 6305 LLU(Part – I) or SKF Ball Bearing 6305- 2RS1 (Part- I) or FAG Ball Bearing 6305-2RSR(Part–II) in Regulating Equipment)

TI/SPC/OHE/ATD/0060 Rev.-1 with A&C Slip No.1

10.2 Stainless Steel Wire Rope for Regulating Equipment.

TI/SPC/OHE/WR/1060(06/2006) With A & C No.1, 2& 3

DWPPL MAC ENGINEERS

11.0 SHORT NEUTRAL SECTION ASSEMBLY (PHASE BREAK) (Required quantity insignificant in comparison to capacities of firms, so capacities are not applicable)

Short Neutral Section Assembly (Phase Break)

TI/SPC/OHE /SNS/ 0000 Rev.-1 with A&C Slip No.1

GALLAND While Placement of Orders, Zonal Railways may re-verify the validity of

Page No. Effective From Valid Till Master List No. Version No.

Page 81 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No. Equipment Current Specification /Drawing No. Vendors for Developmental

Order

Annual Production Capacity

Remarks

1 2 3 4 5 6

MOU/agreement of Indian Representative with OEM. Approved for following combination of conductor S.No

Catenary Wire Grooved copper Contact wire

1 19/2.10 mm, 65 mm2 Cadmium copper

107 mm2

2 19/2.10 mm, 65 mm2 Cadmium copper

150 mm2

3 19/2.79 mm, 65 mm2 Aluminium Alloy

107 mm2

12.0 FITTINGS FOR OHE (FORGED)

TI/SPC/OHE/Fittings/0130 (10/13) with A&C Slip No.1

CEC (RI –5322-1).

KHATRI (RI- 2151-2, 2152-2,2161-2,

2162-2, 2361-1, 2391-1, 2403-

2, 2422-2, 3021-1, 5021,5022,

5023, 5024, 5025 &5041-

1,5322-1)

KF (RI-2151-2,2152-2,2491-

2/2492-2,5322-1 &3071-1)

TLP (RI-2151-2,2152-2,2161-

2,2162-2,2361-1,2391-1, 2403-

2, 2422-2, 2491-2/2492-2,3021-

1, 5021,5022, 5023,

5024,5025,5041-1&5322-1)

BMC

(RI-5041-1,2361-1, 5322-1,

2422-2, 3021-1, 2161-2, 2162-

2, 2391-1, 2403-2)

Page No. Effective From Valid Till Master List No. Version No.

Page 82 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No. Equipment Current Specification /Drawing No. Vendors for Developmental

Order

Annual Production Capacity

Remarks

1 2 3 4 5 6

13.0 TOOLS& PLANT ITEMS 13.1 Tensile Load Testing Machine

for Porcelain& Composite

Insulators

TI/SPC/OHE/INSTEST/0090 (02/2009) with A&C Slip No. 1

CCSPL BCPL

Required quantity insignificant in comparison to

capacities of firms, so capacities are not applicable

14.0 GALVANISED STRANDED STEEL WIRE

14.1 Galvanised Stranded Steel Traction Bond

TI/SPC/GALSTB/0040 with A&C Slip No.1 & 2

MAC ENGINEERS SSEPL

14.2 Galvanised Steel Standard Wire for anchoring of Traction Mast for theft prone areas

TI/SPC/OHE/GSSW/0090 with A&C Slip No. 1 & 2

BWR SHREE

14.3 Spheriodal Graphite Cast Iron

Fitting

TI/SPC/OHE fittings/0130(10/13) with A&C Slip No.1

Kumar Fasteners (RI No.1118-3,1119-3,3073-3 and 3074-3)

BMC

( RI No.1214-3, 1371-3, 1601-3,

1118-3, 1119-3, 3073-3, 3074-3,

1391-3)

Page No. Effective From Valid Till Master List No. Version No.

Page 83 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

CHAPTER – VII

(EQUIPMENT FOR 2X25 kV AT SYSTEM) (Required quantity insignificant in comparison to capacities of firms, so capacities are not applicable)

Note: Status of approval of individual items may not be coterminous with the Vendor Directory’s validity. Consignee/Inspecting authority to verify the current

status of approval from the letter issued by RDSO

S. No. Equipment Technical Specification/ Drawing No.

Approved Vendors Annual Production Capacity

Remarks

1 2 3 4 5 6

1.0 TRANSFORMERS

(a) 54 MVA, 220/2x27 kV, 50 Hz, ONAN, Scott Connected Traction Power Transformer

ETI/PSI/124 (07/1995) with A&C Slip No.1 (Oct. 2016)

ALSTOM(F) ALSTOM (N) KONCAR

(b) 21.6 MVA, 132/2x27 kV 50 Hz, ONAN, Single Phase Traction Power Transformer

ETI/PSI/123 (09/1993) with A &C Slip No. 1 (01/1994) & 2 (Oct. 2016)

TELK

(c) 8 MVA, 54/27 kV, 50 Hz Auto Transformer

ETI/PSI/125 (07/1997) with A&C Slip No.1 (Oct. 2016)

ALSTOM (N) ELECTRO-PUTERE ETE XIAN

2.0 SWITCH GEAR

(a) 25 kV Double Pole Vacuum Circuit Breaker

TI/SPC/PSI/LVCBIN/0120 (Dec.2013) Version - 0 with

A&C Slip No.1 (Oct. 2016)

(b) 25 kV Double Pole Vacuum Interrupters

TI/SPC/PSI/LVCBIN/0120 (Dec.2013) Version - 0 with

A&C Slip No.1 (Oct. 2016)

3.0 CONTROL & RELAY PANEL,RELAYS, SERIES CAPACITOR AND SHUNT CAPACITOR

3.1 CONTROL & RELAY PANEL

(a) Control & relay panel incorporating numerical type protective relays for 2x25kV ac traction Sub-station.

TI/SPC/PSI/PROTCT/7100(07/2012) with A&C Slip No.1

ALIND (T) [Type: ANCRP(2X25KV)] ASHIDA [Type: ACRP 2X25 TSS 01]

(b) Control and relay panel incorporating numerical type protective relays for 2x25 KV Shunt Capacitor Bank

TI/SPC/PSI/PROTCT/7100(07/2012) with A&C Slip No.1

ALIND (T) [Type: ANCB(2X25KV)] ASHIDA [Type: ACRP 2X25 CAP 01]

Page No. Effective From Valid Till Master List No. Version No.

Page 84 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No. Equipment Technical Specification/ Drawing No.

Approved Vendors Annual Production Capacity

Remarks

1 2 3 4 5 6

3.2 Relays

3.2.1 Traction Transformer protection

(a) Numerical 3OC+REF Protection relay for HV side

TI/SPC/PSI/PROTCT/7100(07/2012 with A&C Slip No.1

ALIND (T) [Type: ANTP 402] ASHIDA [Type: A28R]

(b) Numerical Transformer Differential Protection relay

TI/SPC/PSI/PROTCT/7100 (07/2012) with A&C Slip No.1

ALIND (T) [Type: ANTD 401] ASHIDA [Type: A23R]

(c) Numerical Over Current and REF relay for LV side

TI/SPC/PSI/PROTCT/7100(07/2012) with A&C Slip No.1

ALIND (T) [Type: ANTP 302] ASHIDA [Type: A24R]

(d) Numerical Phase failure relay

TI/SPC/PSI/PROTCT/7100(07/2012) with A&C Slip No.1

ALIND (T) [Type: ANPH 201] ASHIDA [Type: A24R]

3.2.2 2X25KV Feeder Protection

(a) Numerical feeder protection relay comprising DPR, OCR, PTFF and Auto reclosure function

TI/SPC/PSI/PROTCT/7100(07/2012) with A&C Slip No.1

*MARUBENI ASHIDA [Type: A21R] ALIND (T) [Type: ANZ 214]

*Prototype test as per revised specification yet to be conducted

(b) Numerical Delta-I & under voltage protection relay

TI/SPC/PSI/PROTCT/7100(07/2012) with A&C Slip No.1

*MARUBENI (TSUDA) ASHIDA[Type: A22R] ALIND (T) [Type: ANPD 212]

*Prototype test as per revised specification yet to be conducted

3.2.3 2x25KV Shunt capacitor bank protection

(a) Numerical Under/Over Voltage protection relay

TI/SPC/PSI/PROTCT/7100(07/2012) with A&C Slip No.1

ASHIDA[Type: A26R] ALIND (T) [Type: ANC 033]

(b) Numerical OC+Current unbalance protection relay

TI/SPC/PSI/PROTCT/7100(07/2012) with A&C Slip No.1

ASHIDA[Type: A25R] ALIND (T) [Type: ANC 402]

3.3 Series Capacitor ETI/PSI/127(08/1989) A&C SlipNo. 1 to 2

MARUBENI (NISSEN)

3.4 Shunt Capacitor ETI/PSI/126(08/1989) A&C SlipNo. 1 to 3

MARUBENI (NISSEN)

4.0 CONDENSER BUSHING

52 kV 800 OIP Condenser Bushing for 8 MVA Autotransformer

IS: 2099 (1986) and RDSO letter No.

TI/PSI/TRNPWR/POLICY/16/01

dated 28.10.2016.

Page No. Effective From Valid Till Master List No. Version No.

Page 85 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

CHAPTER-VIII

REGION-WISE LIST OF FIRMS AND ADDRESSES FORTRACTION INSTALLATION ITEMS

A-Eastern Region S.No Abbreviation Name and address of the Firm Tel & Fax Number e-mail Category Ownership Items

1 2 3 4 5 6 7 8

2. CEC Office Address: M/s Chatterjee Engineering Co.,Sree Ganesh Business Centre, Flat - 2A, 216, AcharyaJagdish Chandra Bose Road, Kolkata-700017.

Fax: 033 – 22876305 ranjit.chatterjee.

[email protected]

S OTH Forged Steel Fittings

for OHE

Works Address: 3/1 Chanditola Branch Road ,Kolkata - 700053

3. TLP Office Address: M/s. Transmission Line Products,102, Central plaza,2/6, First floor,Sarat Bose road, Kolkata-700020.

Fax: 033 – 24858819 [email protected]

om

M OTH Forged Steel Fittings

for OHE

Works Address: 18 Pathak Para Road Behala ,Kolkata -700060 West Bengal

4. ECONOMIC Office Address: M/s Economic Electricals, 125, S.N.Roy Road,Kolkata-700038.

Fax: 033 – 24687621 [email protected] S OTH Section Insulator

Assembly (Without

Section Insulator) Works Address: Bakhrahat Road , Village – Bonogram , Post – Rasapunja ,P.S., Bishnupur

5. PRITHVI Office Address: M/s Prithvi Industries Pvt. Ltd., CF-366,Sector-1, Salt Lake City , Kolkatta-700064

S OTH 25 kV Composite

Insulator

Work Address: M/s Prithvi Industries Pvt. Ltd., MouzaRuia ,P.O.Patulia ,Distt. 24 Parganas (N) ,Kolkatta-700119, email:

info@prithviindu

stries.net

6. BCPL Office Address: M/s BirdmahChemengPvt.Ltd.13 , Camac Street , Kolkata -700017

birdmancpl@aol.

com

S OTH Tensile Load Testing

Machine for 25 kV

Porcelain&

composite Insulators Work Address;M/s BirdmahChemengPvt. Ltd., 5/1 A ,Green Park ,Kolkata -700019,

B- Central Region S.No Abbreviation Name and address of the Firm Tel & Fax Number e-mail Category Ownership Items

1 2 3 4 5 6 7 8

1. BHEL (J) Office Address: M/s Bharat Heavy Electricals Ltd., P.O. BHEL, Jhansi – 284 129.

Tel: 0517-2440944,

Fax: 0517-2443108

[email protected].

in,

rodbhellko@hot

mail.com

OTH OTH Traction Power

Transformer

Works Address: M/s Bharat Heavy Electricals Ltd., P.O. BHEL, Jhansi – 284 129.

Tel: 0517-2440944,

Fax: 0517-2443108

[email protected].

in,

rodbhellko@hot

mail.com

2. BHEL (B) Office Address: M/s Bharat Heavy Electricals Ltd., Transformer Engineering Deparatment ,Bhopal (MP) – 462 022

Phone: 0755-2505686/

2500908 Fax: 0755-

2500681

[email protected]

n, [email protected],

rodbhellko@hot

OTH OTH 25kV Single Pole

Vacuum,Circuit

Breaker

Page No. Effective From Valid Till Master List No. Version No.

Page 86 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

mail.com

Works Address: M/s Bharat Heavy Electricals Ltd., Transformer Engineering Deparatment ,Bhopal (MP) – 462 022

Phone: 0755-2505686/

2500908 Fax: 0755-

2500681

[email protected]

n, [email protected],

rodbhellko@hot

mail.com

4. EPCOS Office Address: M/s EPCOS India Pvt. Ltd, Office: E-22-25, MIDC Area, Satpur, Nashik- 422007. (Maharastra)

Fax: 0253-2353761 tapan.prusty@ep

cos.com

OTH OTH 25 kV Shunt

Capacitor equipment

Works: F- 23-24 MIDC Satpur,Nashik – 422007 (Maharastra) Fax: 0253-2353761 tapan.prusty@ep

cos.com

C- Western Region S.No Abbreviation Name and address of the Firm Tel & Fax Number e-mail Category Ownership Items

1 2 3 4 5 6 7 8

1. AVAL Office address: M/s AditiyaVidyut Appliances Limited, 17, M.I.D.C.,SarawaliKalyan –Bhiwandi Road, Distt.- Thane -421311

Phone: 02522-280203

Fax No. 02522-280246

sales@adityavidy

ut.com

OTH OTH Traction Power

Transformer

Works address: M/s AditiyaVidyut Appliances Limited, 17, M.I.D.C., SarawaliKalyan –Bhiwandi Road, Distt.- Thane -421311

Phone: 02522-280203

Fax No. 02522-280246

sales@adityavidy

ut.com

2. ALSTOM (V) Office Address: M/s ALSTOM T&D India Ltd., LTI Division, Milestone 87, Vadodara Halol Highway, Kotambly, Vadodara -391510

Phone: 02688-661-12,

Fax: 02688-661201

rajat.sharma@als

tom.com

OTH OTH Traction Power

Transformer

Works Address: M/s ALSTOM T&D India Ltd., LTI Division, Milestone 87, Vadodara Halol Highway, Kotambly, Vadodara -391510

Phone: 02688-661-12,

Fax: 02688-661201

rajat.sharma@als

tom.com

3. ASHIDA Office Address for Relays, Control & Relay Panels & SCADA and Works Address for Relays: M/s Ashida Electronics Pvt. Ltd., Plot No. A-308, Road No. 21 Wagle Industrial Estate, Thane- 400604.

Phone: 022-

25827525,25827524,258

27526, Fax: 022-

25804262

sales@ashidaelect

ronics.com

S OTH Numerical Relays

and Control &Relay

Panels for 25 kV and

2x25kV Traction

Sub-Station and

Shunt Capacitor

Bank &

25/ 2 x 25kV SCADA

Equipment.

Works Address for Control & relay Panel and SCADA : M/s Ashida Electronics Pvt. Ltd., Plot No. A-191, Road No. 16AAmbika Nagar, Wagle Industrial Estate, Thane- 400604.

4. ABI Office Address: M/s Aditya Birla Insulators, Halol works: P.O. Meghasar, Halol , Dist. Panchmahal ,PIN – 389330. (Gujarat)

Phone: 91 -2676-

221002,Fax: 91 -2676-

223375

subbarao.p@adit

yabirla.com

OTH OTH 25 KV Composite

Insulator

M/s Aditya Birla Insulators, Halol works: P.O. Meghasar, Halol , Dist. Panchmahal ,PIN – 389330. (Gujarat)

Phone: 91 -2676-

221002,Fax: 91 -2676-

223375

subbarao.p@adit

yabirla.com

5. BWR Office Address: A-701, Trade World, Kamla city, SenapatiBhapatmarg, Lower parel (west), Mumbai – 400013

Phone: 022-

25619960/61/62, Fax

No. 02561 – 9964

info@bharatwire

ropes.com

OTH OTH Galvanised Stranded

Steel Wire For

Traction Mast.

Page No. Effective From Valid Till Master List No. Version No.

Page 87 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No Abbreviation Name and address of the Firm Tel & Fax Number e-mail Category Ownership Items

1 2 3 4 5 6 7 8

Works Address: M/s Bharat Wire Ropes Ltd., WorksAdress: Plot No. 1 &4, At gaon Industrial Complex, Mumbai, Nasik Highway Atgaon(East), Shahapur, Thane

Phone:02527-

240123/240026/240027,

Fax: 02527 –

240196/240544

6. BHARAT Office Address: M/s Bharat Petrolium Corporation Limited ,”A”

Installation Sewree Fort Road , Sewree (East) - 400015

OTH OTH Inhibited Mineral

Insulating Oil

Work Adress: M/s Bharat Petrolium Corporation Limited , Wadibuder, Plant Mallel Road , Wadibunder Mumbai – 400009 , ,

Phone No. 022-

2618061,2618281 Fax

No. 022- 2616793

kashinaths@bhar

atpetrolium.in

7. CGL(M) Office address: M/s Crompton Greaves Ltd., 3rd Floor, Express Building, 9-10 Bahdur Shah ZafarMarg, ITO Crossing , New Delhi– 110002,

Phone No.011-

23460700 Fax No. 011-

23324360

alit.vivarekar@cg

global.com

OTH OTH Traction Power

Transformer

Work Address: M/s Crompton Greaves Ltd.,Transformer Division, Kanjur(E), Bhandup, Mumbai –

400042Phone: 022-

67558000, Fax:022-

67558305,

8. CGL(N) Office address: M/s Crompton Greaves Ltd, Switchgear complex A-3, MIDC, AMBAD, NASIK,(Maharashtra) - 422 010,

Phone: 0253-2382271

to 75 Fax:0253-2381247

shreedhaval.sapr

[email protected]

OTH OTH 220 kV SF6 Circuit

Breakers.

Works address: M/s Crompton Greaves Ltd, Switchgear complex A-3, MIDC, AMBAD, NASIK,(Maharashtra) - 422 010,

Phone: 0253-2382271

to 75 Fax:0253-2381247

shreedhaval.sapr

[email protected]

9. COLUMBIA Office address: Triveni ,32nd Road , Near National College , Bandra(W) Mumbai -400050,

Phone No. 022-

66002313 Fax No. 022-

26463032

[email protected]

t

S OTH Inhibited Mineral

Insulating Oil

Works Address: M/s Columbia Petrochem. Pvt., Limited ,Survey No. 144/1/1, Plot No.12,13,14 ,athalSilvasa , Dadra and Nagar Haveli

10. DWPPL Office Address: M/s Desh Wire Products Pvt., Ltd., 34, Kemtrols Industrial Estae, BhandupSonapur Road, Opposite L.B.S. MargBhandup (West ) , Mumbai – 078.,

Phone: 022 – 25667607

, 25661471 , Fax: 022-

25664317

deshwireproducts

@rediffmail.com

S OTH Stainless Steel Wire

Rope for Regulating

Equipment (ATD).

Works Address: Plot No.D-34 , MIDC(Malegaon) ,Tel- Sinner , Dist. – Nasik Pin –422103 , Maharastra

11. EMCO (T) Office Addrss: M/s EMCO Transformers Limited, Plot No. F-5, Road No. 28, Wagle Industrial Estate, Thane – 400604

Phone: 022-240404500,

Fax: 022-25820571

emco.corporate@

emco.co.in

OTH OTH Traction Power

Transformer

worksAddrss: M/s EMCO Transformers Limited, Plot No. F-5, Road No. 28, Wagle Industrial Estate, Thane – 400604

Phone: 022-240404500,

Fax: 022-25820571

emco.corporate@

emco.co.in

12. FAG Office Address: M/s FAG Bearing India Limited, Maneja,

Vadodara – 390013.

Fax: 0265- 2638804 sandeep.lal@scha

effler.com

OTH Bearing for

Regulating

Equipment (ATD) Works Address: M/s FAG Bearing India Limited, Maneja,

Vadodara – 390013

Fax: 0265- 2638804 sandeep.lal@scha

effler.com

13. MAC ENGINEERS

Office Address: 144, Naman Plaza, Beside Kandivali Flyover, S.V.Road, Kandavali (West),Mumbai-400067

Phone:022-28658106,

Fax:022-28658107

macengineers@h

otmail.com

S OTH Stainless Steel Wire

Rope and Traction

Page No. Effective From Valid Till Master List No. Version No.

Page 88 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No Abbreviation Name and address of the Firm Tel & Fax Number e-mail Category Ownership Items

1 2 3 4 5 6 7 8

Bond (Stranded

Type) Works Address : M/s Mac Engineers , Gat No.87, Village - Pali Naka , Manor–Wada Road , Taluka – Wada , Distt., Thane -421303

Phone: 09867244246,

0252-6211134

macengineers@h

otmail.com

14. KEW Office Address: Kamgar Engineering Works (I) Private Limited, 9, Anupam Industrial Estate, No.2 Opposite Mulund Telephone Exchange, Mulund (West), Mumbai-400 080

Phone: 022-

25908078/79/82, Fax:

022- 25918074

[email protected]

m

S OTH Section Insulator

Assembly (Without

Section Insulator)

Works Address: Kamgar Engineering Works (I) Private Limited, 9, Anupam Industrial Estate, No.2 Opposite Mulund Telephone Exchange,Mulund (West), Mumbai-400 080

Phone: 022-

25908078/79/82, Fax:

022- 25918074

[email protected]

m

15. KHATRI Office: 144, Naman Plaza, Shoppers Stop Bldg., SV Road Kandivali

(West), Mumbai-400067. Phone: 022-28658106,

Fax: 022-28658107

khatricastings@h

otmail.com

S OTH Section Insulator

Assembly (Without

Section

Insulator), Forged

Steel fitting.

Works: Khatri Castings (P) Ltd., Village: Valwada (Near Karambele

Railway Station) NH-8, Taluka- Umargaon, Opposite Maruti Depot,

Dist. Valsad ( SG)

Fax: 0260-2707286

16. Raj Petrospecialities

Office Address: 124,G.D. AmbekarMarg ,Kalachowky, Cotton Green (W) , Mumbai – 400033

Phone no.022-

24714961 Fax No. 022-

24710898

pamumbai@rajg

rp.com

OTH OTH Inhibited Mineral

Insulating Oil

Works Address:M/s Raj PetrospecialitiesPvt. Ltd., Survey No. 146/2/3, Madhuban Dam Road, Village - Karad, Silvasa – Dadar& Nagar Hawveli – 396230.

Phone: 0260 –

3091881, Fax: 0260 -

2644396

17. SHREE Registrered Office: M/s Shree Steel Wire Ropes Ltd., 2nd floor, Shiv Ashish Commercial Complex, Plot No. 10, 19thRoad, Chembur, Mumbai - 400071.

Phone: 022-25274142,

25240917, Fax: 022-

25270999

sswrl@bholenath

cos.com

OTH OTH Galvanised Steel

Stranded Wire for

Traction Mast.

Works Address:183-184-185, KIDC, Village- Dheku, Khopoli, Taluka-Khalapur, Dist. Raigad. (Maharashtra)

PhoneNo.02192-

263547, Fax No. 02192-

266479,

18. SHREEM Office Address: P.B. No. 43, Industrial Estate, Jainsinghpur –416144, email:

Tel.: 02322-

221021/22/24/45 Fax:

02322 – 221023,

admin@shreemel

ectric.com

S OTH Dynamic Reactive

Power Compensation

Work Address : M/s SHREEM ELECTRIC Ltd., Plot No. 03, Gate No. 418/2, L.K.Akawate, Industrial Estate, Jainsinghpur – 416144.

19. HPCL Office Address: M/s Hindustan Petroleum Corporation Ltd.,3rd Floor, Petroleum House, 17, Jamshedji Tata Road, Mumbai-400020.

Tele: +9111-22408506,

Fax: +9111-22013965

[email protected]

.in,

[email protected].

in

OTH OTH Inhibited Mineral

Insulating Oil

Works Address: HPCL, Mazgaon Lube Plant, Haybunder Road, Mazgaon, Mumbai-400033

20. YASH Office Address : M/s YASH High Voltage Insulators Pvt. Ltd., First Floor Chitrakut complex, Above RBL Bank, Racecourse, Vadodara-390007

Tele: 0265-2332100 sales@yashhighv

oltage.co.in

S OTH 52 kV O/P condenser

Bushing for Traction

Power Transformer

Works Address:84/1BKhakhariya, Bh. General Motors, Halol-

Page No. Effective From Valid Till Master List No. Version No.

Page 89 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No Abbreviation Name and address of the Firm Tel & Fax Number e-mail Category Ownership Items

1 2 3 4 5 6 7 8

Champaner Road, Tal.-Savli, Dist. Vadodara-391510

21. GANDHAR Office Address : Gandhar Oil Refinery India Ltd., 18th Floor, DLH Park, S.V. Road, Goregaon West, Mumbai-400062

Tele: 022-40635600

Fax: 022-40635601

sanjayg@gandha

roil.co.in

S OTH Inhibited Mineral

Insulating Oil

Works Address: T-10 MIDC Taloja Main Road, Tal.- Panvel, Dist. Raigad-410208

22. IOC Office Address : Indian Oil Bhawan, G-9, Ali Yavar Jung Marg, Bandra(E), Mumbai-400051

Tele: 022-26447873

Fax: 022-26400606

kmurthi@indian

oil.in

OTH OTH Inhibited Mineral

Insulating Oil

Works Address: Plot No. 75/1, Karajgam, Silvasa-396230 (DN&H)

D- Northern Region S.No Abbreviation Name and address of the Firm Tel & Fax Number e-mail Category Ownership Items

1 2 3 4 5 6 7 8

1. ALSTOM Office Address: M/s ALSTOM T& D INDIA Ltd., Naini Works Allahabad – 211008.

Phone: 0532-2697422

Fax: 0532-2696782,

0522 -4930600Fax

No.0522-4930630

sanjeev.khetrapal

@areva-td.com

OTH OTH Traction Power

Transformers

Works Address: M/s ALSTOM T& D INDIA Ltd., Naini Works Allahabad – 211008

2. ASIATIC Office Address: M/s Asiatic Electrical & Switchgear (P) Ltd., A-58, Naraina Industrial Area, Phase- I, New Delhi.

Phone: 011-

25796330,25796617,

Fax: 011-25799816,

Asiatic@asiatic-

india.com

S OTH 25kV composite

insulators

Works Address: M/s Asiatic Electrical & Switchgear (P) Ltd., A-58, Naraina Industrial Area, Phase- I, New Delhi

3. ELKTRL Office address: M/s Electrolites (Power) Pvt.Ltd., S-758 (A& B), Road No. 9 F, VKI Area Jaipur -302013.

Phone:0141 -

2330576,2331624,

Fax:0141-2333572

marketing@

elecrolites.com

S OTH 25 kV Single

Pole/Double Pole

Motorised Isolators.

Works address: M/s Electrolites (Power) Pvt.Ltd., S-758 (A& B), Road No. 9 F, VKI Area Jaipur -302013

4. TG Office Address: M/s Tools & Gage Company, A-6, Talkatora Industrial Area,Lucknow-226 011.

Phone/Fax:0522 –

2661769

[email protected]

o.in

S OTH 25kV Composite

Insulators

Works Address: M/s Tools & Gage Company, A-6, Talkatora Industrial Area,Lucknow-226 011

5. YPIL Office Address: M/s Yamuna Power & Infrastructure Ltd., SardanaNagar, AmbalaRoad,Jagadhri, Yamuna Nagar –135003.(Haryana)

Phone: 01732-242098,

242881, Fax:01732-

242539

enquiry@yamun

apower.com

S OTH 25kV Composite

Insulators

Works Address: M/s Yamuna Power & Infrastructure Ltd., SardanaNagar, AmbalaRoad,Jagadhri, Yamuna Nagar –135003.(Haryana)

6. KF Office Address: M/s. Kumar Fasteners,S-15, Building Material Phone: 0565 – 2460178, [email protected] Forged Steel Fittings

Page No. Effective From Valid Till Master List No. Version No.

Page 90 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No Abbreviation Name and address of the Firm Tel & Fax Number e-mail Category Ownership Items

1 2 3 4 5 6 7 8

Complex, Site-A, Industrial Area, Mathura(UP)-281004.

Fax: 0565 -2460178 n And SGCI fittings

For OHE

Works Address: M/s. Kumar Fasteners,S-15, Building Material Complex, Site-A, Industrial Area, Mathura(UP)-281004

7. CCSPL Office Address: M/s Concord Control Systems Pvt. Ltd., 202,Garden View Apartments , 8, RanaPratapMarg, Lucknow-226001.

Mob: 09936539555,

Fax: 0522-2818002

concord.controls

@gmail.com

M OTH Tensile Load Testing

Machine for 25 kV

Porcelain &

Composite

Insulators.

Works Address: M/s Concord Control Systems Pvt. Ltd., G-8, UPSIDC Industrial Area, Dewa Road Chinhut, Lucknow-226019..

Mob:

09936539555,Fax:

0522-2818002

E- Southern Region S.No Abbreviation Name and address of the Firm Tel & Fax Number e-mail Category Ownership Items

1 2 3 4 5 6 7 8

1. ABB (B) Office Address: M/s ABB Ltd., Plot No. 5 & 6, II Phase, Peenya Industrial Area, Bangalore – 560 058.

Phone: 080-28392813,

Fax: 080-28392384

[email protected]

bb.com

OTH OTH Dynamic Reactive

Power Compensation

Equipment. Works Address: M/s ABB Ltd., Plot No. 5 & 6, II Phase, Peenya Industrial Area, Bangalore – 560 058

2. ALIND (T) Office address: M/s The Aluminium Industries Ltd., Relays Division, KavinpuramVilappilsala, Trivandrum –695573.(Kerala)

Phone: 0471-2379704,

2379503, Fax: 0471-

2378760

alindrelays@yah

oo.com&binualin

[email protected]

OTH OTH Numerical Relays

and Control Relay

Panels for 25kV

Traction Sub Stations

and 25kV Shunt

Capacitor Bank.

works address: M/s The Aluminium Industries Ltd., Relays Division, KavinpuramVilappilsala, Trivandrum –695573.(Kerala)

3. ALSTOM(H) Office Address: M/s ALSTOM T & D India Limited ,46, Sipcot Industrial Complex,Zuzuwadi,Village – Hosur- 635126.

Phone: 04344408128. OTH OTH 52 kV OIP

Condenser Bushings

for Traction Power

Transformer.

works Address: M/s ALSTOM T & D India Limited ,46, Sipcot Industrial Complex,Zuzuwadi,Village – Hosur- 635126

4. BHEL (B’LORE)

Office Address: M/s Bharat Heavy Electricals Ltd., Electro – Porcelain Division , Indian Institute Of Science, Post Box No. 1245, Bangalore – 560 012.

Phone: 080-23343308,

23348841, 233433309,

Fax: 080-23344231

[email protected]

om

OTH OTH 25 kV Composite

Insulators

Works Address: M/s Bharat Heavy Electricals Ltd., Electro – Porcelain Division , Indian Institute Of Science, Post Box No. 1245, Bangalore – 560 012

5. CMC Office Address: M/s CMC Ltd., CMC Centre, Gachibowli, Hyderabad-500 032.

Phone: 040 –

23000401/ 501, Fax:

040-23000167

bandopadhyay.s

[email protected]

om

OTH OTH SCADA Equipment.

works Address: M/s CMC Ltd., CMC Centre, Gachibowli, Hyderabad-500 032

Page No. Effective From Valid Till Master List No. Version No.

Page 91 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No Abbreviation Name and address of the Firm Tel & Fax Number e-mail Category Ownership Items

1 2 3 4 5 6 7 8

6. DECCAN Office Address: M/s Deccan Enterprizes Ltd., B/58,59 and 60, Asstd.

Pvt. Industrial Estate,Balanagar, Hyderabad-500037. Phone: 040-23870111,

Fax: 040-23778699

[email protected] S OTH 25 kV Composite

Insulators

Works Address: M/s Deccan Enterprizes Ltd., B/58,59 and 60, Asstd.

Pvt. Industrial Estate,Balanagar, Hyderabad-500037

7. DUBAS Office Address: M/s Dubas Engineering Pvt. Ltd., 347/1A, Bilekahalli, 6thCross, 2ndStage, BTM Layout, Office: Bannerghatta Road, Bangalore -560076

mktg3@dubaspo

wer.com

S OTH Dynamic Reactive

Power Compensation

Works Address: M/s Dubas Engineering Pvt. Ltd., 347/1A,

Bilekahalli, 6thCross, 2ndStage, BTM Layout, Office: Bannerghatta

Road, Bangalore -560076

8. ETE Office Address: M/s Thane Electric Supply Co. Ltd., Rahwat Building, 66-A, R P Road, PB-42, Secundrabad.

Phone:040-272756

Fax: 040-274605

Auto Transformer

Works Address: M/s Thane Electric Supply Co. Ltd., Rahwat Building, 66-A, R P Road, PB-42, Secundrabad.

9. GIL Office Address: M/s Goldstone Infratech Ltd., Plot No. 1&9, Phase-2, IDA, Cherlapally, Hyderabad-500051.

Phone: 040-272667-

83/84/85, Fax: 040-

27266785

[email protected]

et

OTH OTH 25 KV Composite

Insulators.

Works Address: M/s Goldstone Infratech Ltd., Plot No. 1&9, Phase-2, IDA, Cherlapally, Hyderabad-500051

10. ITI Office Address: ITI Ltd., Bangalore complex, ITI Ltd., Dooravani Nagar Bangalore –560016

Phone:080 –28503671

Fax No.080 –25650971

[email protected]

n

OTH OTH SCADA Equipment

works Address: ITI Ltd., Bangalore complex, ITI Ltd., Dooravani Nagar Bangalore –560016

11. RAJ PETROSPE CIALITIE(C)

Office Adddress: 2A-D , Doshi Towers , 156, Poonamallee High Road , Kilpauk , Chennai – 600010 Emai ID:

Phone No. 044-

42288900, Fax No. 044-

42288912

marketing_el@ra

jgrp.com/exports

@rajgrp.com

OTH OTH Inhibited Mineral

Insulating Oil.

Works Address: M/s Raj PetrospecialitiesPvt. Ltd., Chennai. S. No.73/1B, Vaikkadu Village, Manali, Chennai-600103.

Phone: 044-29030028,

Fax: 044- 30688900.

12. SST Office address:M/s Switchgears & Structural s ( India) P. Ltd., Plot No. 132& 133,Phase –V , I.D.A., Jeedimetla, Hyderabad – 500055

Phone: 040-23193379,

23193380, Fax: 040-

23193319

switchgear@swit

chgearindia.com

S OTH 25 kV Single

Pole/Double Pole

Motorised Isolators.

Works address:M/s Switchgears & Structural s ( India) P. Ltd., Plot No. 132& 133,Phase –V , I.D.A., Jeedimetla, Hyderabad – 500055,

13. TELK Office Address: M/s Transformers and Electricals Kerala Ltd., Post Angamally Dist. - Ernakulam, Kerala-683 573

Phone: 0484-

2452251,Fax: 0484-

2452873

[email protected];

telk_materials@n

etkracker.com

OTH OTH Traction Power

Transformers

Works Address: M/s Transformers and Electricals Kerala Ltd., Post Angamally Dist. - Ernakulam, Kerala-683 573

Page No. Effective From Valid Till Master List No. Version No.

Page 92 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No Abbreviation Name and address of the Firm Tel & Fax Number e-mail Category Ownership Items

1 2 3 4 5 6 7 8

14. ENERGE Office Address: M/s Energe Capacitor, (P) Ltd., 316, Shree Krishna Commercial Centre, 6, Udyog Nagar, Goregaon, Mumbai.

Phone: 022-40238191 capacitor@energ

e.in

S OTH HT capacitors

Works Address: 1/10, Shenbagathoppy Road, Rajapalayam – 626117.

sales@energecap

acitor.com

15. BMC Office Address: M/s Bangalore Malleable Casting Pvt., Ltd., 7th Mile, Mysore Road, Nayandalli, Bangalore-560039.

Phone: 09845004961,

Fax: 080-2860771

[email protected]

om

S OTH Forged Fittings

&Spheriodal

Graphite Cast Iron

Fitting for OHE

Works Address: M/s Bangalore Malleable Casting Pvt., Ltd., 7th Mile, Mysore Road, Nayandalli, Bangalore-560039

F- Firms Abroad

S.No Abbreviation Name and address of the Firm Tel & Fax Number e-mail Category Ownership Items

1 2 3 4 5 6 7 8

1. ALSTOM (F) Office Address: M/s ALSTOM, Transformateurs of Moyenne

Puissance, Direlltion, Commerciale, 4bd Juies-Durand-7009X, 76086

HAVRECEDEX,FRANCE.

OTH OTH 54 MVA, Scott

Connected Power

Transformer.

Works Address: M/s ALSTOM, Transformateurs of Moyenne

Puissance, Direlltion, Commerciale, 4bd Juies-Durand-7009X, 76086

HAVRECEDEX,FRANCE.

2. ELECTRO-PUTERE

Office Address: M/s TrafoElectroputere, NR 144, Romania. Auto Transformer

Works Address: M/s TrafoElectroputere, NR 144, Romania.

3. KONCAR Office Address: NC Office & Works Address: AR Power Transformer

Ltd., Yuzagreb, Samoborska bb, CROATIA

OTH OTH 54 MVA Scott-

Connected Power

Transformer Works Address: NC Office & Works Address: AR Power Transformer

Ltd., Yuzagreb, Samoborska bb, CROATIA

4. MARUBENI

(NISSIN) Office & Works Address: M/s Marubeni Corporation, 4-2, Ohtemachi,

1-Chome, Chiyoda – Ku, Tokyo, Japan

M/s NISSIN Electric Co. Ltd. Kyoto, Japan

OTH OTH Shunt Capacitor

Equipment, Series

Capacitor

Equipment,

Resonance

Suppressing C-R

Device. C-R Device

Works Address: M/s Marubeni Corporation, 4-2, Ohtemachi, 1-

Chome, Chiyoda – Ku, Tokyo, Japan

5. MARUBENI

TSUDA Office & Works Address: M/s Marubeni Corporation, 4- 2,Ohtemachi,

1-Chome, Chiyoda – Ku, Tokyo, Japan, M/s TSUDA

Electric Meters Co. Ltd., 6-8, NISHITENMA 2-Chome, Kita-Ku

OSAKA, 530, Japan

Phone: 011-23326866

Fax: 011-3325385

OTH OTH Delta-I Fault

Selective Relay,

Feeder Protection

Relay comprising

Page No. Effective From Valid Till Master List No. Version No.

Page 93 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S.No Abbreviation Name and address of the Firm Tel & Fax Number e-mail Category Ownership Items

1 2 3 4 5 6 7 8

Works Address: M/s Marubeni Corporation, 4- 2,Ohtemachi, 1-Chome,

Chiyoda – Ku, Tokyo, Japan, M/s TSUDA

Electric Meters Co. Ltd., 6-8, NISHITENMA 2-Chome, Kita-Ku

OSAKA, 530, Japan

DPR, OCR, PTFF &

Auto reclosure.

6. XIAN Office Address: M/s XIAN Electric Machinery Import & Export Co.,

Mid Section of FengHao Xi Lu, XIAN, P.R. CHINA.

Phone: 0517-2481052 OTH OTH Auto Transformer

Works Address: M/s XIAN Electric Machinery Import & Export Co.,

Mid Section of FengHao Xi Lu, XIAN, P.R. CHINA

7. GALLAND Office Address: The Director Commercial , M/s Galland , 255 ZI de

1’11 liot,33240 La Landa de Fransec, France

j.anselme@gallan

d-sas.com

OTH OTH Light Weight

Sectional Insulator

Assembly and Short

Neutral Section

Insulator Assembly

Works Address: The Director Commercial , M/s Galland , 255 ZI de

1’11 liot,33240 La Landa de Fransec, France

Page No. Effective From Valid Till Master List No. Version No.

Page 94 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

PART-D:

QUALITY ASSURANCE (ELECTRICAL) ITEMS.

CHAPTER IX: ITEMS DEALT BY QUALITY ASSURANCE (ELECTRICAL) DIRECTORATE:

(A) - PS & EMU ITEMS

S. No.

Equipment Current Specification /Drawing No.

Vendors for Development orders

Annual Production Capacity

Remarks

1 2 3 4 5 6

1. Batteries

1.1 Battery for Loco & EMUs

(a) Low Maintenance

Lead Acid Battery 75

Ah for locomotives

(PPCP Container)

RDSO/PE/EMU/SPEC/0

014-2000 (Rev. ‘0’)

with Amendment No.

1&2

a. United Lead Oxide

(5UT75P)

b. Southern – (5 SB75R )

c. Labco – (5T75PEL)

d. CELTEK (C10 VT 75 MP-

LM)

a. (50000)

Page No. Effective From Valid Till Master List No. Version No.

Page 95 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No.

Equipment Current Specification /Drawing No.

Vendors for Development orders

Annual Production Capacity

Remarks

1 2 3 4 5 6

(b) Battery for EMUs 90

Ah (LM) (PPCP

Container)

RDSO/PE/EMU/SPEC/0

014-2000 (Rev. ‘0’)

with Amendment No.

1&2

a. Southern (5SB90R) b. M/s Exide (5 EMU 90 TP-

LM)

a. (1.2 lakh) b. (9000)

1.2 Battery for train lighting

(a) 210 Ah IS:6848-1979

With Amndt. No. 1, 2 &

3 and Annexure H with

correction slip of

RDSO.

1.3 Battery for Air-conditioning

(a) 525 Ah RDSO/PE/SPEC/AC/00

58-2005 (Rev. ‘0’)

a. Southern (SB525R) b. United Lead Oxide (T525P)

(b) 800 Ah RDSO/PE/SPEC/AC/

0058 – 2005 (Rev. ‘0’)

a. United Lead Oxide (T800P) b. Labco (T800HAC) c. Celtek (2GT800PP)*

a. (34800) c. (16320)

*Sister/Allied

concern (Ref:

RB letter no.

2005/Elect

Page No. Effective From Valid Till Master List No. Version No.

Page 96 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No.

Equipment Current Specification /Drawing No.

Vendors for Development orders

Annual Production Capacity

Remarks

1 2 3 4 5 6

(TRS)/441/10 Pt.

dt.02.05.2006.

(c) 450 Ah (MG AC

Coaches)

RDSO/PE/SPEC/AC/00

58-2005 (Rev. ‘0’)

a. Mysore Thermo (Mi 8450TL)

1.4 Battery for TR-D Application

(a) Lead Acid 40Ah -LM RDSO/PE/SPEC/TL/004

0-2003 (Rev-0) with

Amendment No.1

a. M/s United Lead Oxide T40H

(b)

Lead Acid 200Ah -LM RDSO/PE/SPEC/TL/004

0-2003 (Rev-0) with

Amendment No.1

a. M/s United Lead Oxide T200H

2.0 Dry Type Air Filter

2.1 Dry type air filter for

air conditioned

coaches Underslung

& conventional RMPU

RDSO/PE/SPEC/AC/00

55-2OO3 (REV. “2”)

with Drawing no.

RDSO/PE/SK/AC/0057-

2003 (Rev’2’) Sheet 1

of 2 &

RDSO/PE/SK/AC/0057-

a. Shree Shyam Filters, Noida b. Puromatic Filters Pvt. Ltd.,

New Delhi * c. Maharani Industries,

Greater Noida

a. (10000)

*Subject to

revalidation as

per revised

specification.

Page No. Effective From Valid Till Master List No. Version No.

Page 97 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No.

Equipment Current Specification /Drawing No.

Vendors for Development orders

Annual Production Capacity

Remarks

1 2 3 4 5 6

2003 (Rev’2’) Sheet 2

of 2

2.2 Dry Type air filter for

LHB RMPU

RDSO/PE/SPEC/AC/00

55-2OO3 (REV. “2”)

with Drawing no.

RDSO/PE/SK/AC/0073-

2004 (,Rev’1’) &

Drawing no.

RDSO/PE/SK/AC/0074-

2004 ,(Rev’1’)

a. M/s Industrial Filter, Bharuch *

b. Puromatic Filters Pvt. Ltd., New Delhi *

c. Maharani Industries,

Greater Noida

a. (20000) *Subject to

revalidation as per

revised

specification.

3.0 Roof Mounted AC Package Units

3.1 Roof Mounted AC

Package Units

ELPS/SPEC/AC/ 03

(Rev.2) with

Amendment no. 1 &2

a. Amber Enterprises, Rajpura*

*Revalidation as per

revised specification

(Type-II) awaited.

3.2 AC Control panel for

roof mounted AC

package units

ELPS/SPEC/AC/ 04

(Rev.3) with

Amendment no. 1

a.Amber Enterprises, Rajpura

a. (400)

4.0 Electronic Time Delay

Relay for AC coaches

RDSO/PE/SPEC/AC/00

60– 2004, Rev. ‘0’

a. Max Micro Systems, Faridabad

Page No. Effective From Valid Till Master List No. Version No.

Page 98 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No.

Equipment Current Specification /Drawing No.

Vendors for Development orders

Annual Production Capacity

Remarks

1 2 3 4 5 6

5.0 Battery Charger

(a) Battery charger for

110 V, 40 Ah battery

RDSO Spec. No.

ETI/PSI/1 (6/81)

a. Universal Industrial Products, Mumbai

b. Concord Control System Pvt. Ltd., Lucknow

(b) Battery charger for

110 V, 200 Ah battery

RDSO Spec. No.

ETI/PSI/24 (6/81)

a. Universal Industrial Products, Mumbai

b. Concord Control System

Pvt. Ltd., Lucknow

Page No. Effective From Valid Till Master List No. Version No.

Page 99 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

(B)- 25 KV AC TRACTION INSTALLATION ITEMS:

S. No.

Equipment Current Specification /Drawing No.

Vendors for Developmental orders

Annual Production Capacity

Remarks

1 2 3 4 5 6

1.0 POST INSULATORS

(a) 245 kV Solid Core Post

Insulator Assembly for 220 kV

Isolators & Bus Bars.

TI/SPC/OHE/POST/0100

(01/2010) with A & C slip

no. 1

a. SGEL

Vendor Capacity

(minimum for Post

Insulators) included

with OHE Insulators

(b) 132 kV Solid Core Post

Insulator Assembly for 132 kV

Isolators & Bus Bars

TI/SPC/OHE/POST/0100

(01/2010) with A & C slip

no. 1

a. SGEL

Vendor Capacity

(minimum for Post

Insulators) included

with OHE Insulators

(c) 110 kV Solid Core Post

Insulator Assembly for 110 kV

Isolators & Bus Bars

TI/SPC/OHE/POST/0100

(01/2010) with A & C slip

no. 1

a. ABI

b. MIL

c. SGEL

Vendor Capacity

(minimum for Post

Insulators) included

with OHE Insulators

(d) 66kV Solid Core Post Insulator

Assembly for 66kV Isolators

and Bus Bars

TI/SPC/OHE/POST/0100

(01/2010) with A & C slip

no. 1

a. ABI

b. SGEL

Vendor Capacity

(minimum for Post

Insulators) included

with OHE Insulators

(e) Post Insulator Cap & Pin Stack

for 132kV Isolator

IS:2544-1973

(f) Post Insulator for 25 kV Isolator

and Bus Bars (RI 6090)

TI/SPC/OHE/INS/0070

(04/2007) with A & C slip

Page No. Effective From Valid Till Master List No. Version No.

Page 100 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No.

Equipment Current Specification /Drawing No.

Vendors for Developmental orders

Annual Production Capacity

Remarks

1 2 3 4 5 6

no. 1 & 2

(g) 11 kV Post Insulator IS:2544 -1973

2.0 OPERATING ROD INSULATOR:-

Operating Rod Insulator for 25

kV Isolator

(RI 6260)

TI/SPC/OHE/INS/0070

(04/2007) with A & C slip

no. 1 & 2

a. SGEL Required quantity

insignificant in

comparison to

capacities of firms,

so capacities are

not applicable

3.0 INSULATORS FOR OHE AND ASSOCIATED FITTINGS

3.1 STAY ARM INSULATOR:-

Porcelain Stay Arm Insulator

( RI 6000-2) (1050mm CD)

TI/SPC/OHE/INS/0070

(04/2007) with A & C slip

no. 1 & 2

a. SGEL

Required quantity

insignificant in

comparison to

capacities of firms,

so capacities are

not applicable

3.2 BRACKET INSULATORS:-

Porcelain Bracket insulator (RI

6030-1) (1050mm CD)

TI/SPC/OHE/INS/0070

(04/2007) with A & C slip

no. 1 & 2

a.SGEL

Required quantity

insignificant in

comparison to

capacities of firms,

so capacities are

not applicable

Page No. Effective From Valid Till Master List No. Version No.

Page 101 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No.

Equipment Current Specification /Drawing No.

Vendors for Developmental orders

Annual Production Capacity

Remarks

1 2 3 4 5 6

3.3 9-TONNE INSULATORS:-

Porcelain 9-tonne Insulators

(RI 6020-1) (1050 mm CD)

TI/SPC/OHE/INS/0070

(04/2007) with A & C slip

no. 1 & 2

a.SGEL Required quantity

insignificant in

comparison to

capacities of firms,

so capacities are

not applicable

3.4 SECTIONING INSULATORS:-

Sectioning Insulator

(RI 6110) (850mm CD)

TI/SPC/OHE/INS/0070

(04/2007) with A & C slip

no. 1 & 2

a. IEC

Required quantity

insignificant in

comparison to

capacities of firms,

so capacities are

not applicable

3.5 DISC INSULATORS

(a) 11kV, 70 kN, (Ball &Socket type)

Disc Insulator – 280 mm dia,

CD-430mm(min.)

IS:731-1971 a. BHEL ( 4- 980-17-03400)

b. IEC(CQD0702A06)

Required

quantity

insignificant in

comparison to

capacities of

firms, so

capacities are

not applicable

(b) 11kV, 120kN (Ball & Socket)

Disc Insulator with 280mm dia

CD 430mm(min.)

IS:731-1971 a. BHEL(4-980-17-01700)

b. IEC(CQD1204A03)

Required

quantity

insignificant in

Page No. Effective From Valid Till Master List No. Version No.

Page 102 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

S. No.

Equipment Current Specification /Drawing No.

Vendors for Developmental orders

Annual Production Capacity

Remarks

1 2 3 4 5 6

comparison to

capacities of

firms, so

capacities are

not applicable

4.0 TOOLS & PLANT ITEMS

4.1 Gearless Hand Operated Pulling

and Lifting Machine(0.8t, 1.6t,

3.2t)

TI/SPC/OHE/TOOLPL/0990

with A & C Slip No.1 & 2

4.2 Ratchet Lever hoist (Pull Lift)

(0.8 t, 1.6 t, 3.2 t)

TI/SPC/OHE/TOOLPL/1990

with A & C Slip No.1

Page No. Effective From Valid Till Master List No. Version No.

Page 103 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

CHAPTER – X:

ADDRESS OF FIRMS FOR QUALITY ASSURANCE (ELECTRICAL) ITEMS

(A)– PS & EMU Items:-

SN Abbrevi

ation

Name and address of the

firm

Tel & Fax no. Email Catego

ry

Ownershi

p

Items

1 2 3 4 5 6 7 8

1. AMBER M/s Amber Enterprises, C-I,

Phase – II, Focal point,

Rajpura, Punjab – 140 401

01762-232646,

232126,

230570

Fax: 01762-

232127

1. Roof mounted AC Package units.

2. AC Control panel for roof mounted AC

package units

Works address: -do-

2. CELTEK M/s. Celtek Batteries Pvt.Ltd.

471-B IV Phase Peenya

Industrial Area, Bangalore-

560058.

FAX.91-080-

28363355

celtek@g

mail.com

S OTH 1.Battery for Loco & EMUs

a). Low Maintenance Lead Acid Battery 75 Ah

for locomotives (PPCP Container)

2. Battery for Air-conditioning

a) 800 Ah

Works address: -do-

Page No. Effective From Valid Till Master List No. Version No.

Page 104 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

SN Abbrevi

ation

Name and address of the

firm

Tel & Fax no. Email Catego

ry

Ownershi

p

Items

1 2 3 4 5 6 7 8

3. CCSPL Office:

M/s Concord Control system

Pvt. Ltd., 202, Garden View

Apartment, 8, Rana Pratap

Marg, Lucknow – 226001

Fax 0522-2818002

Mob- 9936539555, 9415501553

concord.c

ontrols@g

mail.com

S OTH Battery Charger

Works:

G-8, UPSIDC, Industrial

Area, Dewa Road, Lucknow

– 226019

4. EXIDE Exide Industries Ltd., ‘Exide

House’, 59E Chowringhee

Road, Calcutta-700020.

22478326

Fax:033-

2479819/2407

831

nilanjang

@exide.o.i

n

1.Battery for Loco & EMUs

a). Battery for EMUs 90 Ah (LM) (PPCP

Container)

Works Address – 91 New

Chord Road, PO: Athpur,

Shamnagar-743128;

Durgachak, Haldia-721602,

Dist: Midnapore WB

Page No. Effective From Valid Till Master List No. Version No.

Page 105 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

SN Abbrevi

ation

Name and address of the

firm

Tel & Fax no. Email Catego

ry

Ownershi

p

Items

1 2 3 4 5 6 7 8

5. IFC M/s Industrial Filter

Corporation, J/405/1&2,

Road No. 4, GIDC, Panoli-

394116 Distt-Baruch, Gujrat.

Ph. No. 02646-

272635

Fax: 02646-

272855

Mob:

9824110029

M Dry Type Air Filter for AC coaches for LHB

RMPU.

Works address: -do-

6. LABCO Office:

M/s Lead Acid Battery Co.

(P) Ltd., 18/3 Kumud Ghosal

Road, Kolkata – 700057

033-2564-2037 leadacid57

@gmail.co

m

S OTH 1.Battery for Loco & EMUs

a). Low Maintenance Lead Acid Battery 75 Ah

for locomotives (PPCP Container)

2. Battery for Air-conditioning

a) 800 Ah

Works:

Do

7. MAHAR

ANI Maharani Industries J-43,

UPSIDC, Site-5, Surajpur

Industrial area, Kasna,

Greater Noida, Uttar Pradesh-

201306

Fax no. 011-

26134319

Mob. no.

9899111556

Maharaniind

ustries43@

gmail.com

M OTH Dry type air filter for Underslung, conventional

RMPU & LHB RMPU

Works:

Do

Page No. Effective From Valid Till Master List No. Version No.

Page 106 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

SN Abbrevi

ation

Name and address of the

firm

Tel & Fax no. Email Catego

ry

Ownershi

p

Items

1 2 3 4 5 6 7 8

8. MAX

MICRO

Office: M/s Max Micro

systems, 156, Sunder

Colony, Village- Khedi

Gujran, Post- Pali, Distt.-

Faridabad- 121004

Mob.

9910574886

Fax: 0129-

6524886

maxmicrosy

stems@gm

ail.com

S SC Electronic Time Delay Relay for AC coaches

Works address: -do-

9. MTEPL Office:

Mysore Thermo Electric (P)

Ltd., 62, 4th Main, III Phase,

Peenya Industrial Area,

Bangalore-560058

080-839-

5525/2593

Fax:080-

8394417

info@micr

otex.in

1. Battery for Air-conditioning

a) 450 Ah (MG AC Coaches)

Works:

do

10. PUROM

ATIC

M/s. Puromatic Filters Pvt.

Ltd., 12 DSIDC, Scheme-2,

Okhla Industrial Area,

Phase-II, New Delhi –

110020.

Ph. 011-

26388014,

26388014,

26389158

Mob.

filters@ndb.

bsnl.net.in

M OTH Dry Type Filter for underslung, conventional

RMPU and LHB RMPU

Page No. Effective From Valid Till Master List No. Version No.

Page 107 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

SN Abbrevi

ation

Name and address of the

firm

Tel & Fax no. Email Catego

ry

Ownershi

p

Items

1 2 3 4 5 6 7 8

Works address: -do- 09811824138

11. SHREE

SHYAM

M/s. Shree Shyam Filters, A-

19, Sector-10, Noida –

201301

Fax: 0120-

2534686

Mob:

09911112349

Dry type air filter for AC coaches.

Works address: -do-

12. SOUTH

ERN

Office: M/s. Southern

Batteries Pvt. Ltd., No. 328,

BOMMASANDRA, Jigani

Link road Industrial Area,

JiganiAnekal Taluk

Bangalore – 560099.

M/s Southern Batteries Pvt.

Ltd. Unit-1, Plot No. 30,

KIADB Industrial Area,

Bommasandra, Bangalore -

560099

91-080-78-

34446

vkr@sout

hernbatter

ies.com

M

OTH

1.Battery for Loco & EMUs

a). Low Maintenance Lead Acid Battery 75 Ah

for locomotives (PPCP Container)

b). Battery for EMUs 90 Ah (LM) (PPCP

Container)

2. Battery for Air-conditioning

a) 525Ah

Works address: -do-

13. UIP M/s. Universal Industrial

Products, 27-27A, Block B,

Fax 022- sales@uip Battery Charger for TI application

Page No. Effective From Valid Till Master List No. Version No.

Page 108 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

SN Abbrevi

ation

Name and address of the

firm

Tel & Fax no. Email Catego

ry

Ownershi

p

Items

1 2 3 4 5 6 7 8

Ghatkopar Industrial Estate,

Ghatkopar (West), Mumbai –

400086

25007504

Ph. 022-

25007580,

25008414

.co.in

Works:do

14. ULOP Office:

M/s United Lead Oxide

Product Pvt. Ltd., Plot No.

216, KundaimIndustrail

Estate, Kundaim, Goa-403

115

Ph. 0832-

2395534

contact@j

umbobatte

ryindia.co

m

S OTH 1.Battery for Loco & EMUs

a). Low Maintenance Lead Acid Battery 75 Ah

for locomotives (PPCP Container)

2. Battery for Air-conditioning

a) 525Ah

b) 800 Ah

3. Battery for TR-D Application

a) Lead Acid 40Ah –LM

b) Lead Acid 200Ah -LM

Works:

do

Page No. Effective From Valid Till Master List No. Version No.

Page 109 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

(B) - 25 KV AC Traction Installation Items :-

SN Abbrevi

ation

Name and address of the firm Tel & Fax

no.

Email Catego

ry

Ownershi

p

Items

1 2 3 4 5 6 7 8

1. ABI Office:

M/s Aditys Birla Insulators (A

unit of Aditya Birla Nuvo Ltd.)

P O Prabhas Nagar, Rishra,

Disst.- Hooghly PIN-712249

(West Bengal)

Phone:

033-

26723535,

Fax: 033 –

26722705

www.aditya

birlainsulato

rs.com

11 kV 70 KN & 120 KN Disc Insulators.11Kv And

132 Kv Pedestal Post Insulators.

Works: -Do-

2. ABI Office:

M/s Aditya Birla Insulators,

Halol works: P.O. Meghasar,

Halol, Dist. Panchmahal,

PIN – 389330. (Gujarat)

Phone: 91

-2676-

221002,

Fax: 91 -

2676-

223375

Abi.transmi

ssion@adity

abirla.com

OTH OTH Solid Core Porcelain 25 KV Insulators

Works: -Do-

3. BHEL

(B’LO

RE)

Office:

M/s Bharat Heavy Electricals

Ltd., Electro – Porcelain

Division , Indian Institute Of

Science, Post Box No. 1245,

Bangalore – 560 012.

Phone:

080-

23343308,

23348841,

233433309

,

Fax: 080-

23344231

kvravi@bhel

epd.com

OTH OTH 11 kV,70KN & 120KN Disc Insulators.

Works: -Do-

Page No. Effective From Valid Till Master List No. Version No.

Page 110 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

SN Abbrevi

ation

Name and address of the firm Tel & Fax

no.

Email Catego

ry

Ownershi

p

Items

1 2 3 4 5 6 7 8

3. IEC Office:

M/s Insulators and Electrical

Co., 1-8, New Industrial Area,

P.B. No. 1, Mandideep Dist.-

Raisen (M.P.) PIN-462 046.

Phone:

07480-

400800,

407900

Fax:

07480-

233329,

507908

sln@insulat

orsindia.co

m

OTH OTH Solid Core Porcelain Insulators & 11kV, 70KN

& 120 KN Disc Insulators

Works: -Do-

4. MIL Office:

M/s Modern Insulators Ltd.,

Post Box No. 23, Abu Road –

307 026

Phone:

02974 -

228044/45,

46,48 Fax:

02974 –

228043,

221098

khareajai@

moderninsu

lators.com

OTH OTH Solid Core Porcelain Insulator Insulators

Works: -Do-

Works: -Do-

5. SGEL Office:

M/s Sarvana Global Energy

Limited,Cuddalore Road,

P.N.Kuppam, Kurinjipadi Post,

Cuddalore – 607 302

Phone:

096770778

55,

Fax:

04142-

298880

enquiry@sa

ravanaenerg

y.com

OTH OTH Solid Core Porcelain Insulators

Works: -Do-

Page No. Effective From Valid Till Master List No. Version No.

Page 111 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

PART-E

ENERGY MANAGEMENT ITEMS

CHAPTER – XI (ITEMS DEALT BY ENERGY MANAGEMENT DIRECTORATE)

S. No. Equipment Current Specification /Drawing No. Approved Vendors Annual Production Capacity

Remarks

1 2 3 4 5 6

1.0 Passenger Elevator *

RDSO/2013/EM/SPEC/0016 (Rev ‘0’) Amdt.1

---- - As per asterisk.

2.0 Passenger Escalator **

RDSO/PE/SPEC/TL/0095 ( Rev. ‘1’) -2012

----

- As per asterisk.

* Till RDSO develops sources, Railways may procure this item as per instruction of Railway Board vide letter

No. 2015/Elect(G)/150/2, dated 07.04.2015.

** Till RDSO develops sources, Railways may procure this item from open tender, as per existing system in

vogue and refer RDSO’s Letter No. EL/EM/0005/Escalator, dated 07.12.2015 for Type test.

Page No. Effective From Valid Till Master List No. Version No.

Page 112 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

CHAPTER – XII

STANDARD MAILING LIST:

S.No. COPY HOLDER

Copy No.

1. The Secretary (Elec.), Railway Board, New Delhi-110 001.

K

1.

2. Secretary (Electric Traction), Railway Board, Rail Bhavan, New Del hi-110 001

New Delhi-110 001 ( Kind Attn:Sri Sudesh Kumar, EDEE (RS), Railway Board )

2.

3. The Secretary (RE) Railway Board, New Delhi-110 001.

3.

4. The Secretary (Electric Development) Railway Board, New Delhi-110 001. 4.

5. The Secretary (Stores) Railway Board, New Delhi-110 001. 5.

6. General Manager, Integral Coach Factory, Perambur, Chennai-600 038. 6.

7. General Manager, Rail Coach Factory, PO Hussainpur, Kapurthala-144 602. 7.

8. General Manager, Diesel Locomotive Works, Varanasi – 221 004. 8.

9. General Manager, CLW, Chittaranjan, Distt. Bardwan. 9.

10. CAO, Diesel Component Works, Patiala-147001. 10.

11. General Manager (Electrical), Central Railway, Mumbai CST-400 001. 11.

12. General Manager (Electrical), Western Railway, Churchgate, Mumbai-400 020. 12.

13. General Manager (Electrical), Eastern Railway, Fairlie Place, Kolkata-700 001. 13.

14. General Manager (Electrical), Northern Railway, Baroda House, New Delhi-110 001. 14.

15. General Manager (Electrical), Northeast Frontier Railway, Maligaon, Guwahati-781 011. 15.

16. General Manager (Electrical), North Eastern Railway, Gorakhpur-273 001 16.

17. General Manager (Electrical), South Central Railway, Secundrabad-500 371. 17.

Page No. Effective From Valid Till Master List No. Version No.

Page 113 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

18. General Manager (Electrical), Southern Railway, Park Town, Chennai-600 003. 18.

19. General Manager (Electrical), South Eastern Railway, Garden Reach, Kolkata-700 043. 19.

20. General Manager (Electrical), North Central Railway, Subedar Ganj, Allahabad. 211033 20.

21. General Manager (Electrical), North Western Railway, Jaipur. 302006 21.

22. General Manager (Electrical), WCR, West Central Railway, Jabalpur. 22.

23. General Manager (Electrical), East Coast/Rail, East Coast Railway, Bhubaneshwar 23.

24. General Manager (Electrical), ECR, East Central Railway, Hajipur. 24.

25. General Manager (Electrical), South East Central Railway, Bilaspur. 25.

26. General Manager (Electrical), CORE, Central Organization, Railway Electrification, Allahabad- 211001 26.

27. General Manager (Electrical), South Western Railway Hubli-580020 27.

28. General Manager (Stores), Central Railway, Mumbai CST-400 001. 28.

29. General Manager (Stores), Western Railway , Churchgate, Mumbai-400 020 29.

30. General Manager (Stores), Eastern Railway, Fairlie Place, Kolkata-700 001. 30.

31. General Manager (Stores), Northern Railway, Baroda House, New Delhi-110 001. 31.

32. General Manager (Stores), Northeast Frontier Railway, Maligaon, Guwahati-781 011. 32.

33. General Manager (Stores), North Eastern Railway, Gorakhpur-273 001. 33.

34. General Manager (Stores), South Central Railway, Secundrabad-500 371. 34.

35. General Manager (Stores), Southern Railway, Park Town, Chennai-600 003. 35.

36. General Manager (Stores), South Eastern Railway, Garden Reach , Kolkata-700 043. 36.

37. General Manager (Stores), North Central Railway, Subedar Ganj, Allahabad. 211033 37.

38. General Manager (Stores), North Western Railway, Jaipur. -302006 38.

Page No. Effective From Valid Till Master List No. Version No.

Page 114 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

39. General Manager (Stores), WCR, West Central Railway, Jabalpur. 39.

40. General Manager (Stores), East Coast/Rail, East Coast Railway, Bhubaneshwar 40.

41. General Manager (Stores), East Central Railway, Hajipur –844 101 41.

42. General Manager (Stores), South East Central Railway, Bilaspur 42.

43. General Manager (Stores), CORE, Central Organization, Railway Electrification, Allahabad- 211001 43.

44. General Manager (Stores), CLW, Chittaranjan, Distt. Bardwan. 44.

45. General Manager (Stores), South Western Railway Hubli -580020 45.

46. CEDE, Central Railway, Mumbai CST-400 001. 46.

47. CEDE, Western Railway, Churchgate, Mumbai-400 020. 47.

48. CEDE, Eastern Railway, Fairlie Place, Kolkata-700 001. 48.

49. CEDE, Northern Railway, Baroda House, New Delhi-110 001. 49.

50. CEDE, South Central Railway, Secundrabad-500 371. 50.

51. CEDE, Southern Railway, Park Town, Chennai-600 003. 51.

52. CEDE, South Eastern Railway, Garden Reach , Kolkata-700 043. 52.

53. CESE, Central Railway, Mumbai CST-400 001. 53.

54. CESE, Western Railway , Churchgate, Mumbai-400 020. 54.

55. CESE, Eastern Railway, Fairlie Place, Kolkata-700 001. 55.

56. CESE, Northern Railway, Baroda House, New Delhi-110 001. 56.

57. CESE, Northeast Frontier Railway, Maligaon, Guwahati-781 011. 57.

58. CESE, North Eastern Railway, Gorakhpur-273 001. 58.

59. CESE, South Central Railway, Secundrabad-500 371. 59.

Page No. Effective From Valid Till Master List No. Version No.

Page 115 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

60. CESE, Southern Railway, Park Town, Chennai-600 003. 60.

61. CESE, South Eastern Railway, Garden Reach , Kolkata-700 043. 61.

62. CELE, Central Railway, Mumbai CST- 400 001. 62.

63. CELE, Eastern Railway, Fairlie Place, , Kolkata ;- 700 001 63.

64. CELE, Northern Railway, Baroda House, New Delhi-110 001 64.

65. CELE, Southern Railway, Park Town, Chennai-600 003 65.

66. CELE, South Central Railway, Rail Nilayam, Secunderabad –500 371 66.

67. CELE, South Eastern Railway,Garden Reach, Kolkata -700 043 67.

68. CELE, Western Railway, Churchgate, Mumbai –400 020 68.

69. CEE, Chittaranjan Locomotive Works, Chittaranjan- 713 331 69.

70. CPM/RE, Sealdah, Eastern Railway, DRM Office, Sealdah, Kolkata 70.

71. CPM/RE, Ambala, Northern Railway, Opposite to C.S.D. Ambala Cant,-133001 71.

72. CPM/RE, Eastern Coast Railway, Bhubaneshwar. 72.

73. CPM/RE, Southern Railway, Chennai,. 73.

74. CEE (Cons), Central Railway, 3rd , VT Traction SubStn. Building, D.N. Road, Mumbai CST-400001 74.

75. CEE (Cons), Western Railway, Churchgate, Mumbai-400020 75.

76. CEE (Const), Eastern Railway, Fairlie Place, Kolkata -700001 76.

77. CEE (Const), Northern Railway, Baroda House, New Delhi-110001 77.

78. CEE (Const), Southern Railway, Park Town Chennai-600003 78.

79. CEE (Const), South Eastern Railway, Garden Reach, Kolkata -700043 79.

80. CEE (Const), South Central Railway, Rail Nilayam , Secunderabad-500371 80.

Page No. Effective From Valid Till Master List No. Version No.

Page 116 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

81. CEE (Conv.) DC-AC, 2nd floor, parcel office building, Mumbai CST-400 001 81.

82. CPM (Conv.)DC-AC, 3rd floor ,New Annexe bldg., New Administration Office, Opp: Times of India Bldg.

Mumbai CST- 400 001.

82.

83. CETE/CR, Central Railway, 3rd , VT Traction Sub station, Building, D.N. Road, Mumbai CST-400001 83.

84. CPM/CR(DC/AC, Conv.) Central Railway, 3rd, VT Traction Sub station, Building, D.N. Road, Mumbai CST-

400001

84.

85. MD/RITES, New Delhi House, 27, Barakhamba Road, New Delhi 85.

86. Principal CE/ TI, Thakurli, Distt. Thane, Maharastra 86.

87. Director, IRIEEN, Nasik PO Box No.233, Nasik Road, Nasik. 87.

88. Director, IRCAMTECH, Maharajganj, Gwalior (M.P). 88.

89. Chief Electrical Traction Engineer,Central Railway, Mumbai CST- 400 001 89.

90. Chief Works Manager, Electric Loco Workshop, Eastern Railway, Kancharapara, 24 Pargana (N) -743145

(W.B.)

90.

91. Chief Works Manager, Electric Loco Workshop, Central Railway, Bhusaval- 425 201. 91.

92. Chief Works Manager, Traction Motor Workshop, Central Railway, Nasik-422 101. 92.

93. Chief Works Manager, Loco, Carriage & Wagon Works,Western Railway, Dahod P.O. Freeland Ganj –

389160(Gujrat )

93.

94. Chief Works Manager, Kharag Pur South Eastern Railway Kharagpur. 94.

95. Sr.Divl.Elect.Engineer, Traction Motor Shop, Northern Railway, Fazalganj, Kanpur. -208003 95.

96. Divisional Electrical Engineer, Electrical Repair Shop, Tatanagar- 831 002. 96.

97. Dy. Chief Electrical Engineer, POH Shop/Loco Works, Charbagh Workshop, Northern Railway, Lucknow-

260 005.

97.

98. Dy. Chief Electrical Engineer, POH Shop, South Eastern Railway, Kharagpur (W.B.) 98.

99. Dy. Chief Electrical Engineer, POH Shop, Southern Railway, Perambur, Chennai 99.

Page No. Effective From Valid Till Master List No. Version No.

Page 117 of 117 01-07-2017 31-12-2017 QAE-M-7.1-2 1.0

100. M/s Bharat Earth Movers Ltd., Bangalore Complex Thippasandra, P.B. No. 7501 Bangalore 560 757 100

101. Chief Electrical Traction Engineer South Eastern Railway Garden Reach Kolkata –700043 101

102. Controller of Store, Conkan Railway Corporation Ltd. Belapur Bhavan Sector 11 CBD Belapur Navi

Mumbai – 400614

102

103. Controller of Stores Metro Railway (5Th floor ) Metro Rail Bhavan 33/1 Jawaharlal Nehru Road Kolkata -

700071

103

104. Chief Electrical Engineer Metro Railway (6Th floor ) Metro Rail Bhavan 33/1 Jawaharlal Nehru Road

Kolkata -700071

104

105. DG / RDSO 105

106. ED / QA-Mech. 106

107. EDSE/Co-ordination 107

108. ED/ Traction Installation/Co-ordination 108

109. ED / PS&EMU 109

110. ED/EM 110

111. ED / Motive Power 111

112. ED / Carriage 112

113. Director/Vigilance/ RDSO 113

114. Director/QA (Elect.) 114

115. SSE/DOC CELL/ TI 115