Network Requirements for Avid NEXIS and MediaCentral

242
NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 1 of 242 Network Requirements for Avid NEXIS, and MediaCentral Eur-Ing David Shephard CEng MIET CCDP® CCNP® CCIP® Consulting Cloud Network Engineer TUE 07 DEC 2021 – V2.9 This document is available from: Network Requirements for Avid NEXIS and MediaCentral. http://avid.force.com/pkb/articles/en_US/Compatibility/en244197 Intended audience: General distribution Abstract This NETREQS V2 document outlines the fundamental requirements for Avid NEXIS solutions with MediaCentral, and initially was a slimmed down version of NETREQS V1 for Avid ISIS and Interplay, but has grown with subsequent revisions. It is intended to provide a summary of many documents and site experience. The document sets out minimum requirements where such direction is not explicitly documented, but experience from existing installations is applicable. The document content may be updated in line with product S/W and H/W releases or when other content is added not in direct relation to a recent software release. Externally available URLs will be provided where possible. Some forward-looking content exists which may not occur as expected. This NETREQS document can be shared with customers and used for SoW content.

Transcript of Network Requirements for Avid NEXIS and MediaCentral

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 1 of 242

Network Requirements for Avid NEXIS, and MediaCentral

Eur-Ing David Shephard CEng MIET CCDP® CCNP® CCIP® Consulting Cloud Network Engineer

TUE 07 DEC 2021 – V2.9

This document is available from: Network Requirements for Avid NEXIS and MediaCentral. http://avid.force.com/pkb/articles/en_US/Compatibility/en244197 Intended audience: General distribution

Abstract This NETREQS V2 document outlines the fundamental requirements for Avid NEXIS solutions with MediaCentral, and initially was a slimmed down version of NETREQS V1 for Avid ISIS and Interplay, but has grown with subsequent revisions. It is intended to provide a summary of many documents and site experience. The document sets out minimum requirements where such direction is not explicitly documented, but experience from existing installations is applicable. The document content may be updated in line with product S/W and H/W releases or when other content is added not in direct relation to a recent software release. Externally available URLs will be provided where possible. Some forward-looking content exists which may not occur as expected.

This NETREQS document can be shared with customers and used for SoW content.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 2 of 242

© Avid Technology (Europe) ltd. This document is the property of Avid. The information contained in this document has been provided to the intended recipients for evaluation purposes only. The information contained in this document should not be discussed with any other party or persons without the express prior written permission of Avid. If the intended recipient does not accept these terms, this document and any copies should be returned to the nearest Avid office. If you are not the intended recipient, employee or agent you are hereby notified that any dissemination or copying of this document is strictly prohibited. If you have received this document in error, please return it to the nearest Avid Technology office ( www.avid.com ).

Version 2 is primarily a reformatting exercise in a later version of word (from Word 2003 original) and also features some significant reorganization of content with some legacy content moving to appendices.

Content removal This new Version 2.x document dispenses with the majority of V1.x document content related to ISIS and Interplay, which will remain available but NETREQS V1.X will not be updated beyond V1.23. Some content will be migrated from the old V1.x document, but hopefully the document size will reduce by at least 50% Over time some REALLY useful V1.x content may be re-incorporated.

Branding Changes. This document was first issued as V1.0, 04 July 2007, during that time the products have evolved significantly in nature and name, and the document has grown with them. While many of the product names have changed, in some cases the product has not or there is a logical evolution and in some cases a product revolution. While the headline document name may change the old content will remain, where possible, and applicable or be marked as Legacy content. Current Document HEADLINE Name: Network Requirements for Avid NEXIS, and MediaCentral 2.x (MON YYYY) Previous document HEADLINE names have been:

Network Requirements for Avid ISIS, Avid NEXIS, and Interplay PAM and MAM V1.18 (JUN2016) Network Requirements for ISIS and Interplay PAM and MAM V1.11 (MAR 2013) Network Requirements for ISIS and Interplay Production V1.7 (JUL 2010) Network Requirements for Unity ISIS and Interplay V1.0 (JUL 2007)

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 3 of 242

Table of Contents

Table of Contents

Abstract ......................................................................................................................................... 1

Content removal ............................................................................................................................ 2

Branding Changes. ......................................................................................................................... 2 Additional Contributors .................................................................................................................. 9 Recent Revision history ................................................................................................................... 9 RECENT UPDATE 2.9 ......................................................................... Error! Bookmark not defined.

1.0 AVID NEXIS REQUIREMENTS ................................................................................................... 11 1.0.1 NEXIS and Latency ................................................................................................................ 11 1.0.2 Switch Suitability status ....................................................................................................... 14 1.0.3 Zones - an evolved definition ............................................................................................... 14

1.1 Qualified Switches for Avid NEXIS ....................................................................................... 16 1.1. Issues to be aware of with Dell S4100 Series Switches ......................................................... 18 1.1.2 Dell S4100 Series Switches Model Variants ......................................................................... 19

1.2 Approved Switches for Avid NEXIS ...................................................................................... 19 1.2.1 SWITCH GRADING ................................................................................................................ 21

1.3 Architecturally Capable Network switches .......................................................................... 21 1.3.0 Known Cisco Issues impacting Avid Storage solutions ........................................................ 25 1.3.1 Partially Tested Switches ..................................................................................................... 26

1.4 LEGACY Switches for Avid NEXIS ......................................................................................... 29 1.4.4 Using Force10 S60 with NEXIS ............................................................................................. 29 1.4.3 Using Force10 S25N with NEXIS ........................................................................................... 29

1.5 Transceivers and cables ...................................................................................................... 29 1.5.1 40G QSA or Breakout cables NEXIS ...................................................................................... 30 1.5.2 Breakout cables NEXIS and NEXUS 93180 ........................................................................... 30 1.5.3 Breakout cables NEXIS and DELL OS9/OS10 ........................................................................ 31 1.5.4 Avid supplied 40G Transceivers and NEXIS .......................................................................... 33 1.5.5 3rd Party Transceivers and Switch Vendors .......................................................................... 34 1.5.6 Gigabit Media Converters .................................................................................................... 35

1.6 Switch combinations for E5 NEXIS and Big 40G deployments .............................................. 35 1.6.1 1U Switch Families ............................................................................................................... 36 1.6.2 Chassis Based Switch Families ............................................................................................. 39

1.7 Cisco Catalyst Switches ....................................................................................................... 41 1.7.1 Catalyst 9000 - A series ....................................................................................................... 41 1.7.2 Catalyst 9000 - B series ........................................................................................................ 42 1.7.3 Catalyst 9000 - B series – USING SOFTMAX ONLY ............................................................... 43

1.8 Network Interface Cards ..................................................................................................... 44 1.8.1 Single-mode vs. Multi-mode ................................................................................................ 44 1.8.2 USB-C NIC Information ......................................................................................................... 45 1.8.3 NICs in a VM environment – applies to bare metal too ....................................................... 45 1.8.4 10GBASET Transceivers ........................................................................................................ 48 1.8.5 I350-T2 NIC Eol – Replaced by I350T2V2 ............................................................................. 49 1.8.6 Architecturally Capable NIC Chipsets ................................................................................... 50 1.8.7 Known Vendor NIC Chipsets ................................................................................................ 50

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 4 of 242

1.9 Airspeed 5500 (3rd GENERATION) network connection ........................................................ 50 1.10 NAT/PAT Incompatibility .................................................................................................. 51

1.10.1 Kubernetes – the “core” of the “network” problem with MCCUX .................................... 52 1.10.2 MCCUX “Kubernetes” – NO LONGER USING MULTICAST .................................................. 53

2.0 NETWORK DESIGNS FOR NEXIS ............................................................................................... 54 2.1 Reference designs .............................................................................................................. 54 2.2 Block based designs ............................................................................................................ 55

2.2.1 The Traditional/Legacy way ................................................................................................. 56 2.2.2 MLAG/vPC/VSS Single Controller ......................................................................................... 57 2.2.3 MLAG/vPC/VSS DUAL CONTROLLER .................................................................................... 58 2.2.4 STACKED SWITCH with DUAL CONTROLLER ......................................................................... 59

2.3 CISCO - Custom/Deployed designs ...................................................................................... 59 2.3.1 Cisco Nexus 5600 Based ....................................................................................................... 60 2.3.2 Cisco Nexus 9500 Cases ....................................................................................................... 62 2.3.3 Cisco Nexus 93000 Cases ..................................................................................................... 64

2.4 JUNIPER - Custom/Deployed designs .................................................................................. 65 2.4.1 QFX 10008 and QFX5100 ..................................................................................................... 65 2.4.2 Juniper Buffer limitation with Trident 2 Merchant Silicon .................................................. 66 2.4.3 QFX 10008 and QFX5110 ..................................................................................................... 68 2.4.4 QFX 5120 & EX4400 NETWORK DESIGN .............................................................................. 69

2.5 ARISTA - Custom/Deployed designs .................................................................................... 70 2.5.1 ARISTA 7500R and 7280R ..................................................................................................... 70 2.5.2 ARISTA - PROVEN DEPLOYMENTS WITH NEXIS .................................................................... 70

2.6 SPINE/LEAF - Custom/Deployed designs ............................................................................. 71

3.0 VIRTUAL MACHINES AND BLADE SERVERS .............................................................................. 72 3.1 Cisco UCS ............................................................................................................................ 72

3.1.1 UCS with FI 6248 .................................................................................................................. 72 3.1.2 UCS with FI 6332 .................................................................................................................. 73

4.0 WIDE AREA AND DATA CENTER NETWORKING ....................................................................... 76 4.1 MPLS .................................................................................................................................. 76 4.2 Wavelength-division multiplexing ...................................................................................... 76 4.3 Software Defined Networking –SDN ................................................................................... 77 4.4 VXLAN ................................................................................................................................ 77

4.4.1 VXLAN Overheads ................................................................................................................ 79 4.4.2 VXLAN questions .................................................................................................................. 79 4.4.4 VXLAN and Multicast ............................................................................................................ 80

4.5 Spine/Leaf Networks .......................................................................................................... 80 4.6 Adapter Teaming ................................................................................................................ 80

4.6.1 Teaming with Intel NICs ....................................................................................................... 81 4.6.2 NIC Teaming Windows 2012 ................................................................................................ 81 4.6.3 NIC Teaming Windows 2016 ................................................................................................ 82 4.6.4 Windows Server TEAMING – MORE ARTICLES ..................................................................... 82 4.6.5 Linux Bonding and Teaming ................................................................................................. 82 4.6.6 TEAMING WITH FASTSERVE INGEST .................................................................................... 84

4.7 Cisco Transceiver Enterprise-Class versions ........................................................................ 85 4.8 Jumbo Frames and Avid applications .................................................................................. 86 4.9 NO specific VPN requirements for use with Thin Client applications ................................... 87

5.0 MEDIA CENTRAL ..................................................................................................................... 89 5.1 Media Central UX Bandwidth requirements........................................................................ 89 5.2 Media Central Cloud UX Server Connectivity requirements ................................................ 90

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 5 of 242

7.0 CUSTOM TESTING ................................................................................................................... 91 7.1 TESTING BONDED ADAPTER WITH MEDIA CENTRAL CLOUD UX SERVER .............................. 91

7.1.1 Primary Objective ................................................................................................................. 91 7.1.2 Conclusion Extract ................................................................................................................ 92

7.2 Testing Broadcom 57412 Adapter Media Central Cloud UX Server ...................................... 92 7.2.1 Secondary Objective ............................................................................................................ 92 7.2.2 NIC INFORMATION ............................................................................................................... 93

7.3 JUNIPER QFX5210 and EX4400 APPROVAL - SEP 2021 ......................................................... 95 7.3.1 QFX QFX5120 CUSTOM TEST ............................................................................................... 96 7.3.2 EX4400 CUSTOM TEST ......................................................................................................... 96

99.0 LEGACY ISIS and Interplay Information ................................................................................. 97

Appendix A - NEXIS Documentation - Landing pages ................................................................... 98

Appendix B - Switch configuration tips, good practices and Lessons from the field. ...................... 99 B.1 Document your configs with DESCRIPTIONS ....................................................................... 99

B.1.2 Good documentation and config practices ......................................................................... 99 B.2 Setting Spanning tree to Rapid Spanning Tree ................................................................... 100

B2.1 Spanning tree cost .............................................................................................................. 101 B.2.2 Spanning Cost type ............................................................................................................ 101

B.3 SET primary switch as STP master root primary ................................................................. 102 B.4. SET secondary switch as STP root secondary .................................................................... 103 B.5 Deploy BPDU guard on all ports that use PORTFAST .......................................................... 103

B5.1 Use ROOT GUARD on any interfaces that cascade to other switches ................................ 104 B5.2 Using spanning-tree port type edge with Cisco Nexus and AVID NEXIS ............................. 105

B.6 Use the no shutdown command on all VLANs .................................................................... 105 B.7 Use the shutdown command on all unused interfaces ....................................................... 106 B.8 Enable secret ..................................................................................................................... 106 B.9 Password encryption ......................................................................................................... 106 B.10 Enable telnet ................................................................................................................... 106 B.11 Enable synchronous logging ............................................................................................ 106 B.12 GET A PROPER TERMINAL EMULATOR ............................................................................. 107

B.12.1 PUTTY for Windows ......................................................................................................... 107 B.12.2 ITERM2 for MAC .............................................................................................................. 107 B.12.3 MOBAXTERM for Windows .............................................................................................. 107

B.13 Logging ............................................................................................................................ 107 B.14 Using a Syslog Server ....................................................................................................... 107

B14.1 Freeware logging servers .................................................................................................. 108 B.15 Timestamps ..................................................................................................................... 108 B.16 Setting the Time .............................................................................................................. 109

B.16.1 Command for Cisco NEXUS .............................................................................................. 110 B.17 Show tech support for CATALYST ..................................................................................... 110

B17.1 What is listed?................................................................................................................... 110 B17.2 Show tech-support - CAVEATS .......................................................................................... 111 B17.3 How long does it take? ..................................................................................................... 111 B17.4 useful show commands .................................................................................................... 112 B17.5 TFTP tools .......................................................................................................................... 112

B.18 Handover Practices .......................................................................................................... 113 B.19 Cisco Catalyst 49XX setting of the CONFIG register .......................................................... 113 B.20 Multicast Propagation Does Not Work in the same VLAN in Catalyst and NEXUS Switches ............................................................................................................................................... 113

B.20.1 Multicast Propagation - an Avid perspective ................................................................... 116 B.20.2 – Nexus switches Multicast Propagation ......................................................................... 117

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 6 of 242

Licensing Requirements for PIM: ......................................................................................... 122 B.20.3 – UCS Blade Servers Multicast Propagation .................................................................... 126 B.20.4 Some other useful Multicast URL & Information ............................................................ 126 B.20.5 Some good tutorials on IGMP SNOOPING ....................................................................... 128 B.20.6 Wireshark examples on IGMP SNOOPING ....................................................................... 129

B.21 LoopGuard and FHRP ....................................................................................................... 130 B.22 Speed setting on Switch ports ......................................................................................... 130 B.23 Duplicate IP Address Error Message Troubleshoot – Later Cisco IOS ................................ 133 B.24 Using WINMERGE to compare config files (FIELD-TIP) ...................................................... 134 B.25 Serial connection alternatives to DB9 using USB (FIELD-TIP) ............................................ 134

B25.1. Use the management network on NEXUS switches & remote connection ..................... 135 B.26 Ethernet connection alternatives using USB (FIELD-TIP) ................................................... 136 B.27 Ping testing Cisco links (FIELD-TIP) ................................................................................... 137 B.28 Service Timestamps and Time setting in F10 S4810 & S60 ................................................ 137 B.29 Service Timestamps and Time setting in Dell N3024/48 ................................................... 137 B.30 Service Timestamps and Time setting in DELL S4048 ........................................................ 138 B.31 How to find IP address of a MAC address ......................................................................... 140 B.32 Minimum Length of A Network Cable? ............................................................................ 140 B.33 Cisco Nexus vPC Best Practices ........................................................................................ 141

B.33.1 PATH diversity NEXUS 93000 series switches .................................................................. 142 B.34 Cisco Nexus 93000 series Port Breakout & QSA ............................................................... 144

B.34.1 For Nexus 93180LC-EX ..................................................................................................... 144 B.34.2 For Nexus 93108TC-EX, 93180YC and 9336C-FX2 ............................................................ 146 B.34.3 Optical breakout useful information ............................................................................... 148 B.34.4 TWINAX breakout useful information ............................................................................. 152 B.34.5 QSA adapter ..................................................................................................................... 153

B.35 What is "=" in Cisco part number? ................................................................................... 153 B.36 LINUX BONDING/TEAMING CONFIGURATION FOR ADAPTERS ......................................... 154

B.36.1 TEXT of COMMANDS for SFT ........................................................................................... 155 B.36.2 TEXT of COMMANDS for LACP ......................................................................................... 157 B.36.3 SFT BONDING CONCLUSIONS .......................................................................................... 159 B.36.4 LACP BONDING CONCLUSIONS ........................................................................................ 159 B.36.5 DISCONNECT TESTS CONCLUSIONS ................................................................................. 159 B.36.6 DEPLOYMENT CONSIDERTATIONS with MEDIA CENTRAL CLOUD UX ............................. 159 B.36.7 CHECKING/DEBUGGING LACP BOND CONNECTION STATUS in LINUX ............................ 159 B.36.8 TEAMD or BONDING? ...................................................................................................... 170

B.37 Nexus Watch Command (Field-Tip) .................................................................................. 171 B.38 Automating Backing Up Cisco Config Files ........................................................................ 172

B.38.1CATALYST .......................................................................................................................... 172 B.38.2 NEXUS .............................................................................................................................. 172 B38.3 TFTP from NEXUS to TFTP server ...................................................................................... 173

B.39 NEXUS 93xxx USEFUL COMMANDS .................................................................................. 173 B.39.1 SHOW COMMANDS NEXUS 93xxx USEFUL COMMANDS FROM SHOW TECH................. 173 B.39.2 Show interface counters - Errors only ............................................................................. 176 B.39.3 NEXUS copy run start SHORTCUT .................................................................................... 176 B.39.4 NEXUS other useful alias SHORTCUTS ............................................................................. 177 B.39.5 USEFUL NEXUS COMMANDS FOR MULTICAST DEBUGGING ........................................... 178

B.40 NEXUS FX2 Models and ISIS STORAGE LIMITATIONS .................................................. 181 B.41 Using DHCP with Avid Applications .................................................................................. 182 B.42 IP address allocation with NEXIS and MediaCentral ......................................................... 183 B.43 Navigating Cisco NXOS versions ....................................................................................... 184 B.44 FIELD TIP: large file sending ............................................................................................. 184

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 7 of 242

B.45 FIELD TIP: Upgrading Nexus 9000 switch firmware .......................................................... 185 B.46 Multicast propagation on DELL switches .......................................................................... 188

B.46.1 DELL 0S10 IGMP SNOOPING ............................................................................................ 189 B.47 Multicast propagation on Arista switches ........................................................................ 189 B.48 Useful cabling information .............................................................................................. 190 B.49 LACP for NEXIS clients – is it supported? .......................................................................... 190 B.50 Flow control with AVID Nexis storage – is it needed?....................................................... 192

B.50.1 WHAT TRIGGERS FLOW CONTROL ................................................................................... 193 B.51 Flow control in Cisco NEXUS switches with AVID Nexis storage........................................ 195 B.52 Flow control in Dell S4048 switches with AVID Nexis storage ........................................... 198 B.53 Mellanox ConnectX-3 adapter firmware version in NEXIS ................................................ 199 B.54 DELL S4100 OS10 vs. OS9 LACP and VLT commands ......................................................... 199 B.55 CISCO SWITCH HARDWARE BEACONS .............................................................................. 201

B.55.1 NEXUS 9000 ..................................................................................................................... 201 B.55.2 CATALYST 9000 ................................................................................................................ 202

B.56 DELL N3224 FIRST SETUP ................................................................................................. 203 B.57 DELL N3024 N2024 DEFAULT INTERFACE COMMANDS ..................................................... 204 B.58 DELL N3024 N2024 PASSWORD RECOVERY ...................................................................... 205 B.59 SRT LEARNING RESOURCES .............................................................................................. 206

Appendix C - Power Connections................................................................................................. 207

Appendix D – NEXIS with MLAG Connections sequence............................................................... 208 D.1 C4500X VSS and dual controllers in NEXIS ......................................................................... 208

D.1.1 SDA .................................................................................................................................... 208 D.1.2 ENGINE 1 ............................................................................................................................ 210 D.1.3 ENGINE 2 ............................................................................................................................ 211 D.1.4 ENGINE 3 ............................................................................................................................ 213 D.1.5 ENGINE 4 ............................................................................................................................ 215 D.1.6 ENGINE 5 ............................................................................................................................ 217

Appendix E – Useful articles ........................................................................................................ 219 E.1 Cabling, Optics and Transceivers ....................................................................................... 219 E.2 CISCO FABRIC INTERCONNECT TUTORIAL ........................................................................... 220 E.3 Packet Life and CLOUDSHARK ............................................................................................ 220 E.4 Articles on Loopback interfaces ......................................................................................... 220 E.5 MULTICAST ARTICLES & TUTORIALS ................................................................................... 220 E.6 SDWAN ARTICLES & TUTORIALS ......................................................................................... 222 E.7 AZURE TUTORIALS & ARTICLES .......................................................................................... 222 E.8 KUBERNETES TUTORIALS & ARTICLES................................................................................. 229

Appendix F – Which Cisco Operating system to use? ................................................................... 230 F.1 Catalyst ............................................................................................................................. 230

F.1.2 Which version of (Cisco) IOS is supported? ....................................................................... 230 F.2 NEXUS and NXOS – Which one to choose? ......................................................................... 237

F.2.1 Which version of (Cisco) NXOS is supported? .................................................................... 237

Appendix Z Full Revision history .................................................................................................. 238 Revision history ........................................................................................................................... 238

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 8 of 242

Table of Figures Figure 1 – Reference design for NEXIS with DELL ................................................................................. 55 Figure 2 – Traditional Block design for NEXIS ....................................................................................... 56 Figure 3 – MLAG/VSS Block design for NEXIS ....................................................................................... 57 Figure 4 – MLAG/VSS Block design for NEXIS with dual controllers ..................................................... 58 Figure 5 – Stacked Block design for NEXIS with dual controllers .......................................................... 59 Figure 6 – Custom design for NEXIS with Cisco Nexus 5600 ................................................................. 60 Figure 7 – Custom design for NEXIS and ISIS 7500 with Cisco Nexus 5600 .......................................... 61 Figure 8 – Custom design for NEXIS with Cisco Nexus 9500/93000 ..................................................... 62 Figure 9 – Custom design for NEXIS with Cisco Nexus 9336C-FX2 ....................................................... 64 Figure 10 – Custom design for NEXIS E5 with Juniper .......................................................................... 65 Network Requirements for ISIS 7000 and Interplay PAM and MAM. This document is available from: http://avid.force.com/pkb/articles/en_US/Compatibility/en244197

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 9 of 242

Additional Contributors

Anthony Tanner

Recent Revision history Note Version for this document number DOES NOT directly correlate to ISIS or Interplay Production version For Full Revision History see Appendix Z at end of this document

Version, Name & Date

Comment

Initial Issue V1.0

04 July 2007 - David Shephard

V2.8 24 MAY 2021 222 pages

ADD 1.1.2 Dell S4100 Series Switches Model Variants UPDATE 1.3.0 Known Cisco Issues impacting Avid Storage solutions ADD 1.3.1.5 Cisco Nexus 93180YC-FX3 ADD 1.5.6 Gigabit Media Converters UPDATE 1.8.3 NICs in a VM environment – applies to bare metal too UPDATE 1.6.1 1U Switch Families UPDATE 1.10.1 Kubernetes – the “core” of the “network” problem with MCCUX (added paragraph at end.) ADD 1.10.2 MCCUX “Kubernetes” – NO LONGER USING MULTICAST MINOR UPDATE B.20 Multicast Propagation Does Not Work in the same VLAN in Catalyst and NEXUS Switches ADD 2.5.2 ARISTA - PROVEN DEPLOYMENTS WITH NEXIS UPDATE B.20.2.1 – Field Knowledge NEXUS & Multicast PART 1 UPDATE B.36.2 TEXT of COMMANDS for LACP SIMILAR UPDATE B.36.4 LACP TEAMING CONCLUSIONS SIMILAR UPDATE B.49 LACP for NEXIS clients – is it supported? UPDATE B.36 (.0) LINUX TEAM CONFIGURATION FOR TEAMED ADAPTERS ADD B.36.7 CHECKING/DEBUGGING LACP BOND CONNECTION STATUS in LINUX ADD B.55 CISCO SWITCH HARDWARE BEACONS ADD B.56 DELL N3224 FIRST SETUP ADD B.57 DELL N3024 N2024 DEFAULT INTERFACE COMMANDS ADD B.58 DELL N3024 N2024 PASSWORD RECOVERY

V2.9 07DEC 2021 245 pages

UPDATE 1.0.3 Zones - an evolved definition UPDATE 1.1.1.2 DELL S4100 VLT issue with NEXIS ADD 1.1.1.3 DELL OS10 Certificate Issue UPDATE 1.2 Approved Switches for Avid NEXIS ADD 1.2.1 SWITCH GRADING UPDATE 1.3.0 Known Cisco Issues impacting Avid Storage solutions UPDATE: 1.5.3 Breakout cables NEXIS and DELL OS9/OS10 ADD 1.8.6 Architecturally Capable NIC Chipsets ADD 1.8.7 Known Vendor NIC Chipsets UPDATE 1.5.4 Avid supplied 40G Transceivers and NEXIS

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 10 of 242

Version, Name & Date

Comment

ADD 2.4.4 QFX 5120 & EX4400 NETWORK DESIGN UPDATE 2.6 SPINE/LEAF - Custom/Deployed designs UPDATE 7.1 TESTING BONDED ADAPTER WITH MEDIA CENTRAL CLOUD UX SERVER ADD 7.3 JUNIPER QFX5210 and EX4400 APPROVAL - SEP 2021 ADD 7.3.1 QFX QFX5120 CUSTOM TEST ADD 7.3.2 EX4400 CUSTOM TEST ADD 4.6.4 Windows Server TEAMING – MORE ARTICLES UPDATE 4.6.5.1 LINUX TEAMING UPDATE B.12 Get Putty 0.06 (or later) ADD B.20.5 Some good tutorials on IGMP SNOOPING ADD B.20.6 Wireshark examples on IGMP SNOOPING UPDATE B.36.7 CHECKING/DEBUGGING LACP BOND CONNECTION STATUS in LINUX ADD B.59 SRT LEARNING RESOURCES ADD E.2 CISCO FABRIC INTERCONNECT TUTORIAL ADD E.3 Packet Life and CLOUDSHARK ADD E.4 Articles on Loopback interfaces ADD E.5 MULTICAST ARTICLES & TUTORIALS ADD E.6 SDWAN ARTICLES & TUTORIALS ADD E.7 AZURE TUTORIALS & ARTICLES ADD E.8 KUBERNETES TUTORIALS & ARTICLES ADD F.2 NEXUS and NXOS – Which one to choose?

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 11 of 242

1.0 AVID NEXIS REQUIREMENTS Much of the ISIS information has a direct relevance to NEXIS; however, there will be differences as the product evolves. Avid Knowledge Base Avid NEXIS v7 Documentation http://avid.force.com/pkb/articles/en_US/user_guide/Avid-NEXIS-v7-Documentation Avid Knowledge Base - Avid NEXIS v6 Documentation Documentation and Help files for the Avid NEXIS v6.x releases http://avid.force.com/pkb/articles/en_US/User_Guide/Avid-NEXIS-v6-Documentation Avid® NEXIS™ Network and Switch Guide Version 6.0 http://resources.avid.com/SupportFiles/attach/AvidNEXIS/AvidNEXIS_Network_Switch_v6.pdf

1.0.1 NEXIS and Latency While NEXIS is much more tolerant of dropped packets, using TCP with FRR, and with PATHDIAG can reach 100+ MB/S while dropping packets, testing in SEP 2017 with a data center approx. 30 miles/50KM from corporate offices, the corporate office located NEXIS client performed significantly lower with default settings than a similarly configured client connecting in the data center. The additional RTT latency, as measure by FPING, from client to NEXIS SDA, increased from 0.2ms locally to 1.0ms remotely (average over 60 seconds), the additional 0.8ms extra (average) had a big impact, and the link was not busy because it was a recently installed 100Gbps, operating over a pure dark fibre wavelength, the broadcaster operated its own DWDM over a rented fiber path.

*Given that the speed of light constant in a vacuum, 'c' is exactly 299,792,458 meters per second, the figure of 1 millisecond per 300km might be an accurate estimate for the purpose of latency calculation over distance However, propagation speed in media is significantly lower than c, for glass roughly 1/2 - 2/3 of light speed in vacuum, depending on the refraction index of the media, so a figure of 1 millisecond per 200km is more appropriate. Hence a round trip time (RTT) of 1 ms per 100KM is a working figure is applied to longer distances, but this does not consider delays encountered by network equipment such optical/electrical translation and networks switches.

Jitter or the variation in latency is also a factor, but tends to have less of an impact than latency, 1mS of jitter added to 1mS of latency = 2mS of latency and the performance of the client will suffer. However, the usability of the application is dependent upon the nature of For 1G client it was necessary to change the autotuninglevel from the default setting of DISABLED (after NEXIS client install) C:\Windows\system32> netsh int tcp set global autotuninglevel= disabled | highlyrestricted | restricted | normal

For Windows 7/10/2008/2012 the current setting can be established in a Command windows using C:\Windows\system32>netsh int tcp sh global

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 12 of 242

Using a default PATHDIAG UNLIMITED W/R TEST With RWIN setting as disabled achieve 88/56 MB/S W/R Change RWIN to highly restricted and BW improved to NEXIS to 92/88 MB/S W/R Change RWIN to restricted and BW improved to NEXIS to 92/110 MB/S W/R Change RWIN to normal and BW improved to NEXIS to 94/110 MB/S W/R For a MAC client the setting is likely to be handled more intelligently by the operating system. For a 10G windows client the impact was more significant and this currently under investigation

FPING was used to measure latency as this is accurate to 0.1ms and the extra granularity is required because the default window ping is only accurate to 1mS. http://www.kwakkelflap.com/fping.html (URL MAY NO LONGER WORK IN 2018/9) ALTERNATIVE URL's https://github.com/dexit/fping-windows (works MARCH 2020) http://blog.perceptus.ca/2017/11/10/fping-windows-download-the-last-version/

(works MARCH 2020) and *IX ONLY) https://fping.org/

I have also added a ZIP file with FPING-300 to my Vanilla Configs V0.4 (APR 2019) HRPING A new PING utility found in 2020 is hrPing. I think this is very comprehensive FREEWARE utility available from http://www.cfos.de/en/ping/ping.htm

1.0.1.1 Latency measurements SEP 2017 Based on the SEP 2017 testing: For 1G clients, generally up to 10Km/6 miles is irrelevant, because that adds (in theory) just 0.1ms of incremental RTT. Even up to 100km/60 miles should be fine, because that adds (in theory) just 1.0ms of incremental RTT. But NEXIS with TCP is more sensitive than ISIS with UDP, so I would look at an upper limit of 2ms before some tuning may be required. For 10G clients I would say at the time of writing (JUL2018) Latency above 1ms begins to make its presence felt. Insufficient testing has been done with NLE has been done with various RTT latency variation. However, based on testing for a non-real time workflow and an RTT of 12ms a 10G client was able to achieve a maximum of 28MB/S second WRITE and 78 MB/S READ., but this test only had a single NEXIS engine so might be misleading. The end solution used Nx1G in the client device and multiple NEXIS Engines to achieve a higher data rate.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 13 of 242

Generally Dark fibre vs DWDM, is largely irrelevant, and much depends on whether ISP used true optical multiplexers or electro/optical transponders, and also consider that both types may be used at different parts of the network, optical multiplexers should operate at the speed of light, but electro/optical transponders will add latency, typically 15-100us according to the article below. Also consider that Some ISP services promoted as dark fibre are not, so check the fine print of any SLA and product offering. Hence, budget we should budget for 0.1ms (combining both directions) at each termination point. https://www.telcocloudbridge.com/blog/what-your-dwdm-vendor-did-not-tell-you-about-latency-for-data-center-interconnect/

1.0.1.2 Latency measurements NOV 2018 Based on the NOV 2018 testing using a multisite and multi hop MPLS MAN with 10G presentation, and NEXIS 2018.9 the results are similar to those identified with ISIS 7500 testing in 2012. The table below offers some guidance, but is not an “irrevocable source”, it has been derived from different testing engagements with customer specific workflows. The real time nature of editing high bandwidth video in a collaborative environment means that tolerance for delay and jitter is small. The table below shows that 5ms RTT is the maximum latency, which should be considered acceptable.

Value Behaviour Comments

0-1ms System performs on test network as if locally attached for 1G clients and 10G clients.

2-3ms Minimally noticeable degradation in scrubbing performance, slight delay in play function (minimal) for 1G clients but more noticeable for 10G clients.

RECOMMENDED Maximum Jitter and Latency – combined (UNLOADED) Suitable for codecs up to 120Mbit/s Unsuitable for non-real time high bandwidth workflows

4-6 5ms

Minimally noticeable degradation in scrubbing performance, slight delay in play function (minimal)

RECOMMENDED Maximum Jitter and Latency – combined (UNLOADED) Suitable for codecs up to 50Mbit/s Unsuitable for non-real time high bandwidth workflows

10ms Particularly noticeable delay in scrubbing, 1s delay from pressing play to material playing, may not be suitable for editors

Maybe useable for low bandwidth workflows Unsuitable for non-real time high bandwidth workflows

20ms NOT TESTED UNSUITABLE

50ms NOT TESTED NOT USEABLE

NOTE: subject to change depending on NEXIS client enhancements in subsequent versions.

Based on the tests performed to determine maximum fibre optic distances, up to 5ms is an acceptable latency, depending on the workflow and codec; this translates to a distance of a connection of approx. 1000-1500km* where it would be acceptable to the operator.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 14 of 242

*Given that the speed of light constant in a vacuum, 'c' is exactly 299,792,458 meters per second, the figure of 1 millisecond per 300km might be an accurate estimate for the purpose of latency calculation over distance However, propagation speed in media is significantly lower than c, for glass roughly 1/2 - 2/3 of light speed in vacuum, depending on the refraction index of the media, so a figure of 1 millisecond per 200km is more appropriate. Hence a round trip time (RTT) of 1 ms per 100KM is a working figure is applied to longer distances but this does not consider delays encountered by network equipment such optical/electrical translation and networks switches.

Jitter or the variation in latency is also a factor, but tends to have less of an impact than latency, 5mS of jitter added to 5mS of latency = 10mS of latency and the performance of the client will suffer. However, the usability of the application is dependent upon the nature of the application, for example an Interplay Production Browse client being used to review material will be affected much less by latency than a Media Composer client actively editing.

1.0.2 Switch Suitability status Historically Avid has two levels of switch suitability for project deployment. Qualified and Approved. As described below in Q4 2017 and new category was added. Qualified We sell it or will sell it soon, and it should be tested by Avid with every Major S/W version Dell S4048, Dell N30xx, Cisco C4500X Approved It was tested at a point in time, probably as customer funded testing It was subjected to and passed vendor performed simulation testing Configuration files available on request from “similar projects” Architecturally capable It was subjected to and passed vendor performed simulation testing http://avid.force.com/pkb/articles/en_US/Compatibility/Avid-NEXIS-Network-Switch-Infrastructure

1.0.3 Zones - an evolved definition Historically Avid has used the concept of Zones to describe the connectivity model, and this is discussed in more detail in NETREQS V1.x for ISIS. New concepts and methods such as vPC and MLAG, and advances in technology, have blurred the lines versus the original definitions. With NEXIS, the concept of Zones is less apparent, but the terminology is equally applicable, and suitable edge buffering is still major factor in achieving and maintaining successful workflows. The definition of switch below is one that is explicitly Qualified, Approved, or considered Architecturally Capable.

Zone Definition Description

Zone 1 Does not apply to NEXIS

Zone 2 A layer 2 connection on the same switch and connects with NEXIS, with a known QoS.

Zone 2.1 An indirect connection layer 2 connection on a switch directly subordinate to the switch that and connects with NEXIS, with a known QoS.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 15 of 242

Zone 3 A layer 3 connection, with one routed hop, on the same switch and connects with NEXIS, with a known QoS.

Zone 3.1 An indirect connection layer 3 connection, with one routed hop, on a switch directly subordinate to the switch that and connects with NEXIS, with a known QoS.

Zone 3.5 An indirect connection via multiple layer 3 hops in a tightly controlled network diameter, connection on a switch indirectly linked to the switch that and connects with NEXIS, with a known QoS.

Zone 4 An indirect connection via multiple layer 3 hops with an uncontrolled network diameter, with an unknown QoS, which does not mean insufficient QoS.

Zones were a concept developed for ISIS 7x00 which had physical ports, and the “further” the client went from ISIS the more challenges existed, and the less control was available on the network, Zone 4 was the “Wild West” (well for highly fragmented UDP dataflows it was) of the corporate network with usually low spec networking equipment …. We even talked about a Zone 5 at one time. NEXIS is different in many ways, there is no Zone 1 physical connection possible, it used TCP for payload, hence it was decided to move away from this terminology when discussing networking for NEXIS. While Zone 2, Zone 3 and Zone 4 still have the same absolute meaning, the relevance is reduced, because the dataflow path of NEXIS is more robust (but can still face challenges as I have found from being engaged on some issues in VERY complex networks). The more custom switch testing I do, the more I learn about the resilience of the end-to-end path. In network design for NEXIS one must care less about the number of the hops in the path more about the quality. If the PATH if big enough and the latency is LOW enough a lot can be accomplished for 1G or 10G clients. The 40G clients are still so rare/special that they should be directly connected to the same switch as the NEXIS. Of course, the longer the chain the more potentially problematic links exist. Also, as more vendors and products use merchant silicon, that are more capable than the products typically deployed in the “ISIS Xx00 era”, we also know more about those end-to-end paths. Much of the custom silicon has evolved too, let us consider Cisco Catalyst (not picking on them, they just have several product families that illustrate the point). The C4500/4900 class products were well suited to ISIS 7x00 aggressive dataflow, while the C3000 product were not well suited for this task (but still a great corporate product). The newer C9300/9500 series products which are the evolution of the C4000 and C3000 families are suitable for use with NEXIS with some minor configuration adjustments. Every vendor (or product division within a vendor) will consider their product the BEST outshining all others, but it is necessary to look behind the marketecture and the data sheet and lift the hood. Also consider the same principles apply to NICs…. most NIC vendors are now using merchant silicon, except at the bleeding edge, and there is some very capable silicon available see section 1,8 for more details

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 16 of 242

Many customers are now (since 2018) looking at locating NEXIS and PAM into a data centre in one part of the of a city and having the NLE and corporate offices in other parts of the city. With good planning, good connectivity and good network products this is a successful strategy.

1.1 Qualified Switches for Avid NEXIS Avid has tested or reviewed the following switches for use in an Avid NEXIS environment. 1GbE and 10GbE Switches The following switches work with the Avid NEXIS | PRO, Avid NEXIS | E2, Avid NEXIS | E4, and the System Director Appliance. The switches are listed in no particular order. Cisco Nexus 93180YC-FX, 93108TC-FX, 9348GC-FXP (EX versions also acceptable) -added MAY 2018

Note: The cisco N93180-YC-EX has distance limitation for 25G interfaces (compared to published standards) which are addressed by the newer 93180YC-FX, because it uses a pre-standard Forward Error Correction implementation (FC-FEC) See: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/aci/apic/sw/kb/b_Cisco_ACI_and_Forward_Error_Correction.html#id_50152

And https://supportforums.cisco.com/t5/application-centric/25g-ethernet-consortium-and-or-ieee-standard/td-p/3182146

And https://www.cisco.com/c/en/us/td/docs/interfaces_modules/transceiver_modules/compatibility/matrix/25GE_Tx_Matrix.html **** LINK EXPIRE AUG 2018 in favour of TMGMATRIX.CISCO.COM

For 25 Gbps over 2M (5m typo correction) copper and for 25 Gbps multimode or single mode the forward error correction mechanism is required because of the high-speed transport of the packages over the cables. The published IEEE standard chose for RS-FEC (Reed Solomon" or "Clause 91) as Forward Error Correction mechanism which is used in the FX series 93000 Nexus switches. The ASIC design in the EX series uses FC-FEC ("FireCode" or "BASE-R" or "Clause 74") because it was designed before the final IEEE standards were defined. The ASIC of the 93180YC-EX is designed before the 25G standard was completed, the design of the ASIC of the 93180YC-FX is after the 25G standard. For 25 Gbps over 5 metres copper and for 25 Gbps multimode or single mode the forward error correction mechanism is required because of the high-speed transport of the packages over the cables. In the standard is chosen for RS-FEC as eventually error-correction mechanism. When the ASIC of the – EX Nexus were produced, this choice for RS-FEC was not yet known and there is just no RS-FEC in the ASIC but less powerful FC FEC that allows: the-EX-Nexus up to 3 meters over copper and up to 10 meters with active optical cable,

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 17 of 242

SFP28-25G-SR not LR are not supported on Nexus 9300-EX switches. When the ASIC of the – FX Nexus were produced, the choice for RS-FEC was a standard and therefore RS-FEC is in this ASIC: so, these FX Nexus can handle all distances. So, if you need more than 3 metres on the 93180YC-EX do use the AOC cables: as you can see in the matrix you can with AOC up to 10 meters on the – EX: This 25G distance limitation does not apply to the N9K-X97160-EX-LC line card used in the NEXUS 9500 chassis.

Cisco Nexus 93108TC (see above for N93180YC)

Note: NXOS LICENSING WITHOUT PIM NEXUS 9000 When using the simple no ip igmp snooping command described in section B.20.2.2. NX-OS Essential is sufficient….. NX-OS Advantage (formerly called Enterprise) is not required.

Dell Networking N2024 Dell Networking N3024 Dell Networking S4048-ON

Note: as the NETGEAR XS712T is end of sale the XS716T is acceptable, it is the same architecture but has been tested by AVID.

However, in 2020 some customers experienced issues with this very small buffer switch (especially the XS728T) with a heavy 1G workflow, the nature of very small buffer means it is suitable for 10G clients and 10G storage servers only, and less suited to 1G clients unless a very lightweight workflow.

Cisco Catalyst 4500-X (END OF SALE 31OCT20 announced 31OCT19) https://www.cisco.com/c/en/us/products/collateral/switches/catalyst-4500-x-series-switches/eos-eol-notice-c51-743098.html Cisco Catalyst 4948E (END OF LIFE OCT 2017) effective replacement for AVID is Nexus 9348GC-FXP and not Catalyst 3850 as in URL below: https://www.cisco.com/c/en/us/products/collateral/switches/catalyst-4900-series-switches/eos-eol-notice-c51-738116.html Cisco Nexus 9372 PX/PXE/TX/TXE ( announced end of sale 01 MAY 18 Last day to order is 30 OCT 2018, replacement switch is Nexus 93180 but this is not listed in the EOL notice) at URL https://www.cisco.com/c/en/us/products/collateral/switches/nexus-9000-series-switches/eos-eol-notice-c51-740713.html

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 18 of 242

https://www.cisco.com/c/en/us/support/switches/nexus-9372px-switch/model.html

1.1. Issues to be aware of with Dell S4100 Series Switches This sub section describes some know issues with Dell Switches that impact Avid deployments and may also provide remedial information. Other vendors are addressed in other sections of this document.

Note: Tips from the field. Try this at home

1.1.1.1 DELL OS10 does not support stacking. An S4048 stack running OS9 should not be upgraded to OS10. Dell S4100 devices cannot be stacked and the minimum OS for S4100 is OS10. 1.1.1.2 DELL S4100 VLT issue with NEXIS In JAN 2021 a project using S4148 with NEXIS and VLT encountered problems. A VLT LACP to NEXIS controller would fail but a local LACP on a single switch would succeed. However downstream Dell N3000 switches connecting to VLT/LACP would succeed. The DELL S4148 switch in question was running 10.5.2.2.258. Local Dell support recommended down grade to version 10.5.1.4.249 which resolved the issue toward NEXIS an allowed VLT/LACP to operate correctly apparently other customers have also experience VLT/LACP to HOST devices (e.g., Windows Server, Linux Server, VMWARE ESXi and possibly other hypervisor an operating systems) when running DELL OS 10.5.2.2 on S4100 series switch. See session 1.1.1 regarding know VLT-LACP to HOST in OS10.5.2.2 that will affect NEXIS and possibly ESXi, and likely to affect other platform operating systems/devices too. Current advice [JAN2021] is to downgrade to 10.5.2.0. or 10.5.1.4 to mitigate this issue. As this is a dynamic situation Dell release notes should be consulted for status. UPDATE JUL 2021: According to 10.5.2.6 release notes (Release Date: 2021-06-16), issue ID AR-39361 suggests that an issue was fixed in 10.5.2.3 described as “VLT port channels connected to ESXi hosts do not come up on VLT secondary after upgrade to 10.5.2.2”. Hence 10.5.2.3 becomes the minimum version recommendation, but it also my general advice of using one version before the most recent applies, unless you need a fix only available in the most recent version 1.1.1.3 DELL OS10 Certificate Issue This issue was announced by Dell in June 2021. However, it is unlikely to affect many Avid customers as there use of Dell S4xxx switch as a VLT configuration in an Avid system is rare. I would expect most systems deployed for Avid on S4048 to be running OS9, hence this information can be considered precautionary.

Dell Technologies has identified customers who purchased certain Dell EMC Network Switches that are running the Dell EMC OS10 network operation system and have a preinstalled default security certificate that will expire on July 27th 2021.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 19 of 242

If these default security certificates are allowed to expire, network communications may be severely disrupted which could result in a complete network communication outage. Due to this potential impact, Dell Technologies highly recommends the proactive update of the Dell EMC OS10 Network Operating System to version 10.5.1.0 (or later) or updating the default network security certificate to maintain optimal system performance and avoid encountering this issue. In order to be impacted by this issue ALL of the conditions below must be met: • Dell EMC Network Switch Models: MX5108N, MX9116N, S3048, S4048T, S4112F, S4112T, S4128F, S4128T, S4148F, S4148FE, S4148T, S4148U, S4248FBL-ON, S4248FB-ON, S5148F, S5212F, S5224F, S5232F, S5248F, S5296F, Z9264, Z9332F. • Running: Dell EMC OS10 versions 10.4.1.4 thru 10.5.0.7p3. • Configured: To use VLT (Virtual Link Trunking) or SFS (Smart Fabric Services). For additional details on this issue and information on how to update your Dell EMC Network Switch OS10 version or to update the default security certificate, please go to the following Dell Knowledge Base Article: https://www.dell.com/support • Search for Knowledge Base Article “184027” • Alternatively input your service tag. • Go to “Documentation” • Under Documentation select “Top Solutions” and look for article 184027 - “Dell EMC Networking OS10 Certificate Expiration and Solution”

1.1.2 Dell S4100 Series Switches Model Variants As at MAR2021 the current model list is: S4112F-ON 12x 10G and 3x 100G S4112T-ON 12x 10GbT and 3x 100G S4128F-ON 28x 10G and 2x 100G S4128T-ON 28x 10GbT and 2x 100G S4148F-ON 48x 10G and 2x 40G and 4x 100G S4148T-ON 48x 10GbT and 2x 40G and 4x 100G They all use the same chipset so there is no appreciable difference in the capability of each model in regard to operation with NEXIS and/or MediaCentral. It is possible that other model variants may be added in time.

1.2 Approved Switches for Avid NEXIS Avid has tested or reviewed the following switches for use in an Avid NEXIS environment. Arista Networks 7048 Arista Networks 7150S Arista Networks 7280SE Cisco Catalyst 4900M Cisco Catalyst 4948-10GE Cisco Nexus 7000 series (specific I/O Cards) Cisco NEXUS 93180 LC –Deployed Q4 2017 [ NEXUS 93180 FAMILY BECAME QUALIFIED IN MAY 2018]

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 20 of 242

Cisco NEXUS 9336C-FX2, 93240YC-FX2, Nexus 93360YC-FX2 and Nexus 93216TC-FX2 (these are

evolutions of NEXUS 93180 FAMILY, but may have issues with ISIS storage see section B.40). Cisco Nexus 5672 and Nexus 2248TPE FEX – Deployed Q1 2017 Europe

Any Cisco NEXUS 56xx parent switch with: Nexus 2248TPE FEX, Nexus 2348 UPQ FEX, 2348 TQ/TQE FEX, 2232 TQ FEX

NETGEAR XS712T - for small NEXIS PRO solutions Juniper QFX 5120 Tested SEP2021 Grade 3 Capability, Resilience Grade 3 Juniper EX4400 Tested SEP2021 Grade 2 Capability, Resilience Grade 1 (as tested, Grade 3 expected) FEX COMPATIBILITY MATRIX for NEXIS 9000 NXOS https://www.cisco.com/c/dam/en/us/td/docs/Website/datacenter/fexmatrix/fexmatrix.html

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 21 of 242

1.2.1 SWITCH GRADING

GRADE DESCRIPTION NOTES

1

Suitable with Avid NEXIS clients using medium resolution and a codec less than 100Mbit/s (including audio). Supports a maximum of 5 streams. Clients will generally connect with a single 1Gb path. Avid NEXIS Engines can connect at 10Gb.

Shared egress buffer less than 10MB.Fewer than 33% of the ports should be concurrently active.

2

Suitable for use with Avid NEXIS clients using high resolution setting and codec less than 300Mbit/s (including audio). Supports a maximum 9 streams at resolutions below 100Mbit/s. Clients will generally connect with a dual active 1G path. Avid NEXIS Engines can connect at 10G or 40G.

Generally, a shared egress buffer of 10-30MB. However, the structure of the buffer might dictate that some switches with buffers >10MB are classed as Grade 1. Fewer than 66% of ports should be concurrently active.

3

Suitable for use with Avid NEXIS clients using ultra high-resolution setting. Clients will generally connect using a single or dual 10G connection. Avid NEXIS Engines can connect at 10G or 40G.

Generally, a shared egress buffer greater than 30MB. However, the structure of the buffer might dictate that some switches with buffer >30MB are classed as Grade 2.

4 Connection for 40Gb clients Use Qualified Solution only.

U UNTESTED

T TESTED

F FAILED TESTING

Resilience Grade Legend

1 LACP only

2 LACP & FHRP (standards based VRRP and/or proprietary)

3 LACP & FHRP & MC-LAG (standards based and/or proprietary)

1.3 Architecturally Capable Network switches In NOV 2017, Avid has decided to create a new “standard level” of Architecturally Capable, in addition to Qualified and Approved, the URL below provides further information. http://avid.force.com/pkb/articles/en_US/Compatibility/Avid-NEXIS-Network-Switch-Infrastructure

Qualified: o Fully qualified for a broad range of applications. Qualified switches are typically part

of the Avid engineering and test labs and part of ongoing testing. (Qualified switches are listed in the Avid NEXIS Network and Switch Guide for your release version.)

Approved: o Approved for deployment as detailed in the Avid ISIS / NEXIS & Media

Central Network Requirements Document. (Approved switches are typically tested at a customer site as part of a specific commissioning engagement. Approved

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 22 of 242

switches are listed in the Avid NEXIS Network and Switch Guide for your release version.)

Architecturally Capable: o Architecturally Capable switches have been stress tested by the switch vendor in

coordination with Avid and subject to an Avid specific test plan (see below for details). This Knowledge Base article is the only source of information for architecturally capable switches with Avid NEXIS.

Architecturally Capable Switches (as at DEC 2021) Check URL Above for updates Architecturally Capable Switches (alphabetically by switch vendor)

Switch Vendor Product Notes Grade

Arista Networks 7020TR-48 48x100/1000Mb and 6 SFP+ 2

7020SR-24C2 7020SR-32C2

24x10G and 2 QSFP100 32x10G and 2 QSFP100

3

7050SX2 7050TX2

2

7280 Family 7500 Family

E-Series (10/40GbE) or R-Series (10/25/100GbE)

3

Aruba Networks 8320

1/10GbE (SFP/SFP+ and 10GBASE-T) and 40GbE connectivity

2

8325

1/10GbE (SFP/SFP+ and 10GBASE-T) and 40GbE connectivity (excessive capability for use as a 1GbE edge switch)

3

3810

1/10GbE (SFP/SFP+ and 10GBASE-T)

1

Cisco Nexus

Nexus 93180YC-EX Nexus 93180YC-FX Nexus 93180LC-EX Nexus 93180TC-EX Nexus 93180TC-FX

Tested 1G, 10G, and 40G Ethernet See the latest Avid Network and Switch Guide on

3 Qualified

Nexus 9336CFX2

Not explicitly tested but a variation of above package. 36 100G ports (100/50/40/25/10/4x10/4x5) SFP28 presentation.

3 Approved

Nexus 93240C-FX2 Nexus 93360C-FX2

Variation of Nexus 9336C-FX2 with different physical presentation, offering more 10/25GbE ports (and fewer

3 Approved

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 23 of 242

100GbE ports)

Cisco Catalyst

C9300-24UB C9300-48UB C9300-24UXB

Second-generation Catalyst 9300 series with deeper buffers. Suitable with 10G Avid NEXIS Engines as: Edge switches to a larger system Self-contained single switch core/access for small, stand-alone systems Smaller systems using stacked configuration to provide resilient solution In general: smaller, entry-level systems with moderate workflows. You must modify the default buffer configuration, which is not deep enough for correct operation with Avid NEXIS. See Network Requirements for Avid NEXIS, ISIS and Interplay / Media Central for Softmax Configuration Details for Cisco Catalyst C9300B series.

1

Dell N2200 Series N2200 Series are comparable replacements for N3000 series.

1

Dell N3200 Series N3200 Series are good replacements for N3024/3048.

1 or 3, depending on exact model

(packet buffer memory)

Juniper Networks

QFX5100 Testing completed at Layer 2 1

Juniper Networks

QFX5120

Testing completed at Layer 2/3 with VRRP/MLAG/VC core configurations and as edge switch

3

Juniper Networks

EX4400

Testing completed at Layer 2/3 with LACP core configuration and as edge switch

2

Mellanox Spectrum

SN2700 SN2410 SN2100 SN2010

2

Mellanox Spectrum

SN3000 series

3

Mellanox Spectrum

SN4000 series

3

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 24 of 242

Architecturally Capable Switches: Merchant Silicon -- Small Buffer

Switch Vendor Product Buffer Size Notes Grade

Broadcom Trident 2/2+ 12.2/16MB 10/40G; also supports 1G edge switch

2

Broadcom Maverick 12.2MB 10/40G; also supports 1G edge switch

2

Broadcom Helix 4MB 1G edge switch and/or two Avid NEXIS Engines at 10G

1

Broadcom Tomahawk 16MB

10/25/40/50/100G devices* not well suited to 1G edge use but amply capable

2

Broadcom Tomahawk+ 22MB

10/25/40/50/100G devices* not well suited to 1G edge use but amply capable

2

Broadcom Tomahawk2 42MB

Primarily a 100G core switch not aimed at 1G/10G edge use but capable

3

Broadcom Trident 3 X4, X5, X7

32MB 1/2.5/5/10/25/40/50/100G devices* depending on variant

3

* NOTE: Avid NEXIS systems and clients do not currently support 2.5G, 5G, 25G, 50G, or 100G speeds.

Architecturally Capable Switches: Merchant Silicon -- Deep Buffer

Switch Vendor Product Buffer Size Notes Grade

Broadcom Dune N x 32GB 10/40G; also supports 1G edge switch

3

Broadcom Qumran N x 4GB 10/25/40/100G; also supports 1G edge switch

3

Broadcom Jericho N x 4GB 10/25/40/100G; also supports 1G edge switch

3

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 25 of 242

1.3.0 Known Cisco Issues impacting Avid Storage solutions Devices

Considering a defect where UDP packages are misclassified as described below. https://bst.cloudapps.cisco.com/bugsearch/bug/CSCva22756 It is recommended that all Nexus 93000 EX series (2nd and 3rd generation) products used with any Avid storage (ISIS or NEXIS) is deployed as/or upgraded to a minimum Nexus version S/W version of 7.0(3)I7(3) (FEB 2018). RELEASE NOTES: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/release/notes/70373_nxos_rn.html?referring_site=RE&pos=2&page=https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/release/notes/70377_nxos_rn.html

SUBSQUENT Q2/2021 INORMATION USE A MINIMUM OF 7.0(3)I7(6), ideally higher. NOTE this BUG has since been found in later versions Nexus version S/W version of NXOS version 7.0(3)I7(6) should be used with AVID ISIS application, AVID NEXIS should not be impacted, but this cannot be ruled out- I HAS BEEN SEEN TO IMPACT SOME NEXIS SYSTEMS TOO! Hence MINIMUM version for NEXIS should also be NXOS version 7.0(3)I7(6) This applies to all Nexus 93108, 93180, 9500 chassis-based switches using 2nd generation or 3rd generation hardware (I.E using the N9K-C95xx-FM-E Fabric card.) should use this software.

The Cisco NEXUS 9336C-FX2 should be added to the above list. I have recommended it to MANY customers, usually in combination with a N93180YC/TC OR N9348GC. It is basically two N93180YC-FX “glued” together with all 100G (40/25/10/4x10/4x25) presentation. Its edge buffering capabilities are fairly irrelevant as a core switch. Nexus 93000 FX series products should use a minimum Nexus version S/W version of NXOS version 7.0(3)I7(6). (MAR 2019) RELEASE NOTES: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/release/notes/70376_nxos_rn.html?referring_site=RE&pos=2&page=https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/release/notes/70377_nxos_rn.html

Ideally use 7.0(3)I7(8) or later in the NEXUS 7.x family.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 26 of 242

The Cisco NEXUS 9336C-FX2 QSA BUG Link flap might cause the port to go down. CSCvq65989 Symptom: A Nexus 9000 series switch might experience ports stuck in down/down state after a link flap event. Known Affected Releases: 7.0(3)I7(7), 9.2(3), 9.2(4), 9.3(1) Known Fixed Releases: 9.3(2) ,7.0(3)I7(8) Affected ports: 1/1-6 and 1/33-36 May also impact NEXUS 93240-FX2 and 93360-FX2 This has affected one deployment (Q2/20) that a using and unusually high number of QSA instead of optical breakout.

https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/release/notes/70378_nxos_rn.html https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/93x/release/notes/cisco-nexus-9000-nxos-release-notes-933.html Not forgetting the “original” killer bugs CSCue96534 and CSCuj73571 – for Cisco Catalyst 4xxx in 2013.

1.3.1 Partially Tested Switches Devices listed here have undergone some basic testing, but may not have been tested with simulated traffic by the manufacturer, or had a full load test with 44 (or equivalent) clients. 1.3.1.1 C2960X Testing with NEXIS (JUL 2017) The C2960X has just 4MB of packet buffer, whereas the C4948E has 17.5MB. The C2960X would not be able to support ISIS 7500 clients, but the NEXIS data flow is different, and the “standard Dell switch” model N3024/3048 sold by Avid also only has 4MB of RAM, however the buffer organization of some lower cost Cisco switches has been found to be incompatible with the Avid data flow, so this opportunity was taken to do rather basic testing with a small number of workstations The C2960X drop packets, and this was somewhat expected, but it has shown itself to be capable of handling relatively high loads of NEXIS data. It must be state however that this test used only 10 workstations, but those workstations were drawing a much higher load than in normal workflows. The READ BW flowing through the C2960 was approx. 640MB/S

640

RATE STREAMS

XDCAM HD 50 8 80

AVCI -100 14 45

DNxHD120 16 40

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 27 of 242

DNxHD120 18.5 34

DNxHD145 23.5 27

DNxHD220 28 22 Dependent on the working video resolution that may well exceed normal operational requirements these values suggest the C2960X, with two 10G uplinks can support AVID NEXIS video traffic for 1G clients connecting to 10G E4 engines (the result for 40G connecting Engine could be quite different, even though there would be buffering stages in between at the 40G to 10G transition. The interface discard counters were monitored and also the interfaces statistics, which are reported over the default 300 second/5-minute period. As can be seen below the discard %age is approx. 0.02%

This switch should not be considered and approved switch, for use with NEXIS based on this testing mini-test. However, based on this mini-test it is consider “acceptable deployment” but without a commitment to explicitly support by Avid. 1.3.1.2 Cisco Nexus 9348-GC-FXP Field testing (FEB 2018) The Cisco Nexus 9348GC-FXP Switch is a 1RU switch that supports 696 Gbps of bandwidth and over 250 mpps. The 48 1GBASE-T downlink ports on the 9348GC-FXP can be configured to work as 100-Mbps, 1-Gbps ports. The 4 ports of SFP28 can be configured as 1/10/25-Gbps and the 2 ports of QSFP28 can be configured as 40- and 100-Gbps ports. The Cisco Nexus 9348GC-FXP is ideal for big data customers that require a Gigabit Ethernet ToR switch with local switching. This switch has not been tested by Avid with ISIS 7500 but is being considered for use with NEXIS (as at MAR2018 – WAS QUALIFIED FOR NEXIS IN MAY 2018), generally any switch capable of working with ISIS 7500 is suitable for NEXIS.

Note: This switch uses the 3rd generation Nexus 9000 chipset and has been successfully field tested with ISIS 7500 (in March 2018) by a forward-thinking customer using a small number of clients running AVCI-100 video resolution it was necessary to upgrade the switch to NXOS S/W version of 7.0(3)I7(3) (FEB 2018). Earlier version supplied on the switch did not operate correctly with ISIS 7500.

Discards@ Discards@ Discards@ Discard10MIN 20MIN 30MIN Per1MIN Per5MIN packets/5minutes %age

30 6portG1/0/1 0 0 0

portG1/0/2 29313 56172 81069 2702 13511 135,725,668 0.01%portG1/0/3 27535 53800 80164 2672 13360 134,490,242 0.01%portG1/0/4 41828 43419 121109 4036 20184 136,190,776 0.01%portG1/0/5 19755 40022 58011 1933 9668 66,658,029 0.01%

portG1/0/6 19554 40366 58345 1944 9724 66,235,063 0.01%portG1/0/7 7546 13988 22431 747 3738 33,240,438 0.01%portG1/0/8 3478 5469 9004 300 1500 5,298,000 0.03%

portG1/0/9 28934 55309 81232 2707 13538 138,796,895 0.01%portG1/0/10 44382 90238 133101 4436 22183 137,115,475 0.02%portG1/0/11 31429 61274 90372 3012 15062 89,052,152 0.02%portG1/0/12 0 0 0

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 28 of 242

SUBSQUENT Q2/2021 INORMATION USE A MINIMUM OF 7.0(3)I7(6), ideally higher.

Considering a defect where UDP packages are misclassified as described below. https://bst.cloudapps.cisco.com/bugsearch/bug/CSCva22756 It is recommended that all Nexus 93000 series (2nd and 3rd generation) products used with any Avid storage (ISIS or NEXIS) is deployed as/or upgraded to a minimum version S/W version of 7.0(3)I7(3) (FEB 2018). This applies to all Nexus 93108, 93180, 9500 chassis-based switches using 2nd generation or 3rd generation hardware (I.E using the N9K-C95xx-FM-E Fabric card.) should use this software. SUBSQUENT Q2/2021 INORMATION USE A MINIMUM OF 7.0(3)I7(6), ideally higher.

1.3.1.3 Cisco Nexus 93180YC-FX (QUALIFIED MAY 2018) The Cisco Nexus is a later generation of the N93180YC-EX, and has a very similar buffer architecture to the N93180YC-EX. It also addresses 25G/100G interface distance limitation but using RS-FEC instead of FC-FEC used in the N93180YC-EX. 1.3.1.4 Cisco Nexus 9336C-FX2 and 93240YC-FX2 The Cisco Nexus is an evolution of the Cisco Nexus 93180YC-FX (QUALIFIED MAY 2018), and has a very additional buffering using two FX series ASICS and provide a higher port count of 10G interfaces. However, buffering in the core switch is of less relevance than an edge switch for Avid “FAT” clients.

Nexus 93000 FX series products should use a minimum Nexus version S/W version of NXOS version 7.0(3)I7(6). (MAR 2019) *** This addresses a UDP fragmentation Bug. - CSCvm70117 *** *** Fragmented UDP packets goes to CPU - BFDC v4 PACKET IETF *** First found as CSCue96534 Catalyst 45XX (2013 Cisco IOS-XE software version 3.3.x and 3.4.0). The only fragmented packets that are “dropped” [I.E .STOLEN AND NEVER

RETURNED] contain the value 3784 or 3785 where the UDP L4 portion would be if the packet were a non-fragment. RELEASE NOTES: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/release/notes/70376_nxos_rn.html?referring_site=RE&pos=2&page=https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/release/notes/70377_nxos_rn.html

nxos.7.0.3.I7.6.bin even better nxos.7.0.3.I7.8.bin. (MAR 2020) https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/release/notes/70378_nxos_rn.html

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 29 of 242

1.3.1.5 Cisco Nexus 93180YC-FX3 The Cisco Nexus 93180YC-FX3 launched Q1 2021 is an evolution of the Cisco Nexus 93180YC-FX (QUALIFIED MAY 2018) and has a very similar buffering. At the time of writing this section (MAY 2021) there is no intention by Avid to test this device, as it is not deemed necessary. The FX3 variant is an evolution of the existing FX switch platform, with additional features like FEX mode along with a few more not important of minimal relevance to Avid dataflows, like Telecom PTP, and some telemetry features. Buffer is exactly the same as for FX, single slice with 40MB of shared buffer. However, this Platform required NXOS 10.x and at the time of writing (MAY 2020) Avid has zero experience with this version. From A FEX operation perspective this platform should exceed the capability of previously tested FEX platforms, and NXOS 10 is required.

1.4 LEGACY Switches for Avid NEXIS Many questions are asked about using old network switches from previous ISIS 5x00 and 7x00 deployment when upgrading to NEXIS.

1.4.4 Using Force10 S60 with NEXIS Late 2015 the S60 network switch became End of Sale. There appears to be no direct replacement for the S60N that had very large buffers of 1.25 GB. As this is a legacy switch there are no plans for Avid to test it. Avid does not explicitly support this switch with NEXIS. However, it is considered architecturally suitable for any workflow. Generally, any switch that was capable of supporting ISIS 5x00 data flows should be capable of supporting NEXIS data flows. The limited quantity of 10G ports on this switch suggests it will only be used on smaller NEXIS systems only or as a cascaded access switch from a higher capability core switch.

1.4.3 Using Force10 S25N with NEXIS In 2015 the S25N network switch became End of Sale. There direct replacement being the Dell N3024. The S25N has small buffers (unlike the S60), just 2MB, and this is arranged as 1MB per 12 port group. Avid does not explicitly support this switch with NEXIS. Generally, any switch that was capable of supporting ISIS 5x00 data flows should be capable of supporting NEXIS data flows, however this switch is unlikely to be able to support aggressive workflows, but is expected to be able to support limited workflows (i.e. 50Mbit/s data rate) and/or client quantity. Note that the S25N has TX and RX crossed on the RJ45 connector. For the Dell F10-S25 I have used a RJ45 cat 5e coupler and a standard “twisted” Ethernet cable, as my “get out of jail” solution to fit on the end of my Cisco rolled cable. Imperfect but seems to work.

1.5 Transceivers and cables Questions are often asked about this area. Some explanations are given below

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 30 of 242

1.5.1 40G QSA or Breakout cables NEXIS Using a Cisco 40G- 10G QSA or 4x10G break out cables is no issue, as they are physical layer devices. But QSA adapters a very inefficient because you get 1 x 10G port from a 40G port. I have successfully used a Cisco QSA adapter with a NEXUS 5648 while doing some ISIS 7500 testing. The QSFP breakout cables is not something I have used myself, and the Cisco data sheet is POOR http://www.cisco.com/c/en/us/products/collateral/interfaces-modules/transceiver-modules/data_sheet_c78-660083.html Apparently there is not a 40G to 10G x4 “empty” SFP+ option, that can be used in conjunction with an SFP+ into of your choice (i.e. SR or LR etc.) Hence you would have to use the

QSFP-4SFP10G-CU (0.5M,1M,2M, 3M,4M, 5M) - QSFP to 4 SFP+ copper break-out cables This gives the equivalent of four TWINAX cables that could be connected to NEXIS, so you still get 40G worth of throughput. Avid has not tested this cable, but it should present exactly the same as a single 10G TWINAX that Avid have tested. Some more details can be found in Appendix B.34

1.5.2 Breakout cables NEXIS and NEXUS 93180 From a DEMONS Mail thread in MAY 2019 Question about connecting E4 10G port to Cisco Nexus 93180LC-EX 40G port…….. or 93108TC-EX. ……………the devil is in the detail here. Short answer: NOT TESTED but should be fine. This is all standards-based connections. Long answer: There are so many cable/transceiver/breakout variations, Avid will NEVER tested them all, and probably only one or two!! Even Cisco has challenges with its new Transceiver Module Group (TMG) Compatibility Matrix https://tmgmatrix.cisco.com/home The Nexus 93180 EX family all use the same chip inside. (Principle described below apply equally to FX models) The model variants have different external presentation. It is all based around a chip that has 100G ports that can present as 100G, or 2x50G or 4x25G or 1 x 40G or 4 x10G or…. with QSA adapter 1x 10G or 1 x 1G (yes a 100G port working as a 1G port….. but sometimes it has to be done). So, the 10/25G SFP ports are just a (backend) 100G port externally (physically) presented at four independent ports, to which one can connect and SFP+ or SFP28 or 10G TWINAX or 25G TWINAX (or AOC cables…. But that is another can of worms that Avid does not test because the Mellanox CX3 NIC in NEXIS does not officially support AOC). Hence, a single path TWINAX presents and SFP “style” connection the same a 4x10G TWINAX from “single” 100G ports. It is just with breakout cable there is additional configuration necessary versus a “hard port”. To go to my favourite car metaphors: Same car…….. different style doors, some with tinted windows some without.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 31 of 242

Also never forget the 1/10G ports on a 93108TC-EX are just as fast capable as a 10G SFP+ port on the N93180YC-EX, it is just the distance options that differ based on transceiver selection.

1.5.3 Breakout cables NEXIS and DELL OS9/OS10 This should not really be necessary on a Dell S4048-ON but is likely if using a S4048T-ON. Which has RJ45 1/10GBaseT ports instead of SFP+ ports. Bear in mind S4048T-ON is not sold by Avid. There are three choices

1. TWINAX break out 40G to 4x10G, 5 m max distance 2. OPTICAL breakout, form QSFP+ via external breakout panel as described in my NETREQS section B.34.3 Optical breakout useful information Each of these will give you 4 x 10G ports, and will need additional commands in the config

Lastly… 3. Use a QSA adapter (and then fit a 10G SFP+), which turns 40G port into a single 10G port, which is inefficient, especially of you need multiple 10G ports

None of these are sold by Avid so must have been provide externally, in which case the reseller should asked their supplier of the DELL switch. For the S4048 RUNNING OS9 switch the command to breakout a QSFP into lanes is stack-unit x port yy portmode quad for example:

stack-unit 1 port 49 portmode quad

and now each 10G child lane is configurable individually for example:

interface TenGigabitEthernet 1/49/1

description " NEXIS SDA Engine TOP-CTL 10G Port 1"

no ip address

flowcontrol rx on tx off

!

port-channel-protocol LACP

port-channel 10 mode active

no shutdown

interface TenGigabitEthernet 1/49/2

description "NEXIS E4 Engine #1 TOP-CTL 10G Port 1"

no ip address

flowcontrol rx on tx off

!

port-channel-protocol LACP

port-channel 11 mode active

no shutdown

interface TenGigabitEthernet 1/49/3

description "NEXIS E4 Engine #2 TOP-CTL 10G Port 1"

no ip address

flowcontrol rx on tx off

!

port-channel-protocol LACP

port-channel 12 mode active

no shutdown

interface TenGigabitEthernet 1/49/4

description "NEXIS E4 Engine #3 TOP-CTL 10G Port 1"

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 32 of 242

no ip address

flowcontrol rx on tx off

!

port-channel-protocol LACP

port-channel 13 mode active

no shutdown

This example also uses a port channel connection example. This method works for both QSA use where a QSFP+ port is effectively populated by one 10G SFP, and four both optical and DAC style breakout cables. There are several sites running combinations of this approach. When running OS10 the commands are different, the example below is based on the “all 100G “DELL S5232F The equivalent command in OS 10 is interface breakout [port number] map [speed]g-[quantity of lanes]x which serves two purposes, (1) to break the “parent” QSFP port out into “child” lanes, and (2) to set the speed of the child lanes.

Syntax interface breakout node/slot/port map {100g-1x | 50g-2x

|40g-1x | 25g-4x | 10g-4x | 25g-4x} Parameters node/slot/port — Enter the physical port information.

100g-1x — Reset a QSFP28 port to 100G speed.

50g-2x — Split a QSFP28 port into two 50GE interfaces.

40g-1x — Set a QSFP28 port to use with a QSFP+ 40GE

transceiver.

25g-4x — Split a QSFP28 port into four 25GE interfaces.

10g-4x — Split a QSFP28 or QSFP+ port into four 10GE

interfaces

For Avid NEXIS E2/E4/SDA/E5-NL use when deriving 10G ports from the QSFP28 socket this example for the DELL S5232F switch, converts the first QSFP 28 port into four 10G SFP lanes:

interface breakout 1/1/1 map 10g-4x

Now the QSFP28 parent port 1/1/1 is broken out into four child ports 1/1/1/:1, 1/1/1/:2, 1/1/1/:3, and 1/1/1/:4 each of which can now be configured individually as below:

interface port-channel 127

description ―NEXIS SDA Engine TOP-CTL LACP PATH‖

switchport mode trunk

switchport trunk allowed vlan 123

no shutdown

!

interface ethernet1/1/1:1

description "NEXIS SDA Engine TOP-CTL 10G Port 1"

no shutdown

switchport access vlan 123

flowcontrol receive on

spanning-tree port type edge

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 33 of 242

channel-group 127 mode active

no shutdown

!

interface ethernet1/1/1:2

description "NEXIS E4 Engine #1 TOP-CTL 10G Port 1"

no shutdown

switchport access vlan 123

flowcontrol receive on

spanning-tree port type edge

no shutdown

!

interface ethernet1/1/1:3

description "NEXIS E4 Engine #2 TOP-CTL 10G Port 1"

no shutdown

switchport access vlan 123

flowcontrol receive on

spanning-tree port type edge

no shutdown

!

interface ethernet1/1/1:4

description "NEXIS E4 Engine #3 Top C TOP-CTL 10G Port 1"

no shutdown

switchport access vlan 123

flowcontrol receive on

spanning-tree port type edge

no shutdown

This example uses a port channel connection only on the SDA. Note the use of the “:” character on the broken-out port rather than another “/” character. Also, all ports in the breakout must use the same speed.

For connecting 25G VM servers use “

interface breakout 1/1/2 map 25g-4x

This has not been tested but IT MAY BE REQUIRED when connecting a 40G MEXIS E5 engines 25G VM servers use “

interface breakout 1/1/3 map 40g-1x

1.5.4 Avid supplied 40G Transceivers and NEXIS This should be rather simple, Historically the E5 & E5SSD could be ordered with 7070-35070-00 Avid NEXIS 40GbE QSFP MPO connector Optic SR (100m, Short Range) for E5 & E2 SSD controller (Mellanox MC2210411-SR4) (40GbE, InfiniBand FDR10 SR4 MPO 150m 850nm) Or you could use TWINAX, originally the was no Long Range option but that changed in SEP 2017 (from a Mellanox perspective) with the MC2210511-LR4 being supported in the NIC when the later firmware Rev 2.42.5000 (SEP 2017) or later is deployed in the controller. But the MC2210411-SR4 became EOL by Mellanox See: https://www.mellanox.com/related-docs/eol/LCR-000407.pdf so Avid had to change

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 34 of 242

But what to connect it with…. There are many twists and turn here, to describe just one: The first is that this particular challenge has NO constant naming of this 40G connectivity option between vendors, unlike other well defined 40GBASE standards like SR4 and LR4. It appears that it is called: Arista call it “QSFP-40G-XSR4” Cisco QSFP-40G-CSR4” Dell (and apparently Huawei) call it “qsfp-40g-esr4” Extreme 40G-QSFP-eSR4 Juniper QFX-QSFP-40G-ESR4 Mellanox MC2210411-SR4E. (40Gb/s, QSFP, MPO, 850nm, up to 300m) All apparently the same thing. Standards are a wonderful thing but sometimes the vendors just add to the confusopoly for their own purposes. The other thing about the Cisco part and again there appears to be a lack of commonality I expect that this applies to the others is that the Cisco “extended” range devices also support 4x10G breakout while the standard version do not, but for Mellanox it seems to be the opposite. Apparently “standard” SR4 can interconnect with “extended” SR within the limits of “standard” SR4, but I can only find ONE article to support that: https://community.cisco.com/t5/other-data-center-subjects/interconnect-qsfp-40g-sr4-with-qsfp-40g-csr4/td-p/3219528. Another vendor has confirmed (APR 2020) that SR4E has a more powerful laser and a higher power class, and that it can communicate with the lower power SR4 (100m, Short Range) device within the capabilities of the lower power device.

Note: While later versions of NEXIS E5 40G controllers can use a Mellanox 40 LR transceiver, the precise version of the embedded Mellanox driver (which is NOT DIRECTLY related to the NEXIS firmware version) must be firmware-version: 2.42.5000 or higher if this is required.

1.5.5 3rd Party Transceivers and Switch Vendors Fundamentally this is "beauty contest" between the switch vendors all wanting to sell their own branded products at good margin. In reality correct operation is ultimately a function of Vendor codes programmed into the local EEPROM on the transceiver/TWINAX, and there are many vendors (web search will provide a long list) that sell "guaranteed compatible" devices with the correct EEPROM codes already programmed appropriately for “intended switch vendor”, because in reality all the optical transceivers and TWINAX cables are made by a restricted number of suppliers, just as most NICS are based on a small collection of merchant silicon. Nexus 9k and Nexus 3k (and later version of Nexus 7K) don't have enforced ban of 3rd party transceivers, when you plug in a 3rd party transceiver system (e.g. a different vendor TWINAX cable) will display syslog that transceivers is not supported, but will allow port to function correctly providing the cable/transceivers is in line with IEEE standard. Some other Nexus switches need

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 35 of 242

additional commands to service the unsupported transceiver (web search will provide as it may not be "polite" to share this here). Hence using a Mellanox cable from a Mellanox NIC to a Cisco Nexus 9000 switch will work, but you may well get some benign "advisory/complaining" log entries in the switch.

1.5.6 Gigabit Media Converters In NETREQS Version 1. (final version v1.24) there is a whole appendix (F) on media converter testing, originally from 2006. The Allied Telesis models (MC1004 and MC1008) see to have been superseded by now, but the TPLINK device is still available. Media converters are pretty basic devices, usually layer 1, so not much “invention” going on….a bit like wheel and tyres, they are round and will (probably) always be round. Some folk used to think there was a performance impact for these devices, but generally they just work… there is no buffering to consider, light pulses go in and electrical pulse come out and vice versa of course (no rocket science here) So, in 2021 what might I suggest: Premium Product. Allies Telesis https://www.alliedtelesis.com/en/products/media-converters/mmc2000lc

These products tend to be layer 2 device due to additional management functions

This vendor provides some impressive large scale media conversion solutions too

Street price approx. EUR/USD 150 Basic no-nonsense product. TPLINK MC220L or MC 200CM/ MC210CS https://www.tp-link.com/uk/business-networking/accessory/mc200cm/ (BTW it won’t be calling home!!) • One point which may be seen as advantageous (or not depending on perspective) is the FIXED transceiver which means that no SFP needs to be purchase. Separately.

Streep price EUR/USD 40 https://www.tp-link.com/uk/business-networking/accessory/mc220l/

Streep price EUR/USD 30, SFP transceiver extra There are many other suitable vendors such as Black Box or Startec, they all do the same simple job, as with many “things Ethernet” they are all made in the same group of factories by OEM suppliers and given different paintjobs and branding.

1.6 Switch combinations for E5 NEXIS and Big 40G deployments The explicitly approved switches generally have limitation on the 40G ports, which limits the size of E5 based solutions with full resilience. Many switch vendors use the same merchant silicon, and product families of a single vendor may share common silicon and hence buffering capability amongst 1U/2U products and chassis-based products. If 40G and 10G variants of 1U products can be stacked it might be possible to stack different models from the same family subject to vendor OS capability/limitations.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 36 of 242

The list below is not exhaustively tested or possibly explicitly supported and is provided for information purposes only: For Avid NEXIS storage is it the edge buffering toward the NEXIS clients that need the most buffering.

1.6.1 1U Switch Families One Avid qualified switch (2016-2020 – then End of Sale) for NEXIS is the Broadcom Trident 2 based S4048, but the Dell S6000 is the same device but with 40G presentation, so can be used alongside with S4048 for 10/1G and Dell N3024/48 for 1G clients (NLE of Server). Cisco Nexus 9332PQ for 40G with N9372 (also Avid approved) for 10/1G (all same Broadcom Trident 2 chipset 12+ 25MB buffer in ALE chip)

Note End of sale announced 05MAR19 end of support 24MAR24 https://www.cisco.com/c/en/us/support/switches/nexus-9332pq-switch/model.html

Arista 7050QX for 40G and 7050SX/TX for 1/10G (all same Broadcom Trident 2 chipset) (we have done “some tests”) Cisco Nexus 93180YC-EX (1/10/25 & 40/100) 93108TC-EX, (1/10 & 40/100) and 93180LC (25/40/50/100) all have same (Home-grown Cisco) chip, LSE "40MB" is 18.7MB per slice and used 2 Slices. Arista 7280 QR for 40G and 7280 SR/TR for 1/10G (all same Broadcom Jericho chipset with 4GB buffers, not tested -yet– but VERY capable) As this is Nexis, also for 1G edge consider the Arista 7010T which is same chipset (Broadcom Helix) as Dell N3048 The HPE FlexFabric 5930 uses same Broadcom Trident 2 chipset (and the 5900 was Trident + [like the F10-S4810] which would also be acceptable, but this is now considered a legacy switch) The HPE Altoline 6900 Switch uses Broadcom Helix and provides 48G 4XG 2QSFP All info above is in the public domain. These alternative switches may not have been tested by Avid, and may not explicitly supported by Avid, hence no guarantee of operation can be assumed. However, one might consider the likelihood of successful operation with NEXIS clients, using one of these products to be high. Many of the switches below could be used a Core or Edge in large systems. Some switches categorized as “edge” could be use as the Core in small non-40G systems. The table below both summarizes and extends this information given above This is not an exhaustive list as the product families are continually changing and evolving with newer generations both merchant silicon and custom silicon. Some of them may already exist in proven deployments.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 37 of 242

1.6.1.1. SWITCH TABLE

BRAND MODEL TYPE CHIPSET BUFFER

Dell S6000 40G switch Broadcom Trident 2 12.2MB

Dell S4048 10G Switch Broadcom Trident 2 12.2MB

Dell N3024/48 1G RJ45 Switch Broadcom Helix 4MB

Cisco NEXUS N9332PQ

“EOL ANNOUNCED”

40G switch Broadcom Trident 2 & Cisco ALE

40 MB

Cisco NEXUS N9372 PX-E

“EOL ANNOUNCED”

1/10G Switch Broadcom Trident 2 & Cisco ALE

40 MB

Cisco NEXUS N9372 TX-E

“EOL ANNOUNCED”

1G RJ45 Edge Switch

Broadcom Trident 2 & Cisco ALE

40 MB

Cisco NEXUS N93180 LC-EX 25/40/50G switch

Cisco LSE 37.4MB

Cisco NEXUS N93180YC-EX 1/10/25 switch Cisco LSE 37.4MB

Cisco NEXUS N93108TC-EX 1/10G RJ45 Switch Cisco LSE 37.4MB

Cisco NEXUS

Nexus 9300FX

93180YC-FX

N93108TC-FX 1/10/25G Switch LS1800FX 40 MB

Cisco NEXUS 9336C-FX2 93240YC-FX2

93360YC-FX2

10/25/100G

Various models

Cisco LS3600FX2 40 MB

Cisco NEXUS 93216TC-FX2 1/10G copper & 100G x 12

Cisco LS3600FX2 40 MB

Cisco NEXUS Nexus 9300 (9332C, 9364C) 40/100G Switch S6400 40 MB

Cisco NEXUS

Nexus 9300FX3

N93180YC-FX3 1/10/25G Switch LS1800FX3 40 MB

Cisco NEXUS Nexus9300GX 40/100G Switch LS6400GX 80 MB

Cisco NEXUS 5672 UP 1/10/40 switch Cisco UPC 150MB

Cisco NEXUS 5624/5648 PQ

“EOL ANNOUNCED”

10/40 switch Cisco UPC 360MB

Cisco NEXUS 5696Q 10/40 switch Cisco UPC modular

Cisco Catalyst 9300B 1/10G switch UADP 2.x XL 32MB

Arista 7050QX 40G switch Broadcom Trident 2 12.2MB

Arista 7050SX 1/10G Switch Broadcom Trident 2 12.2MB

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 38 of 242

Arista 7050TX 1/10G RJ45 Switch Broadcom Trident 2 12.2MB

Arista 7020TR 1G RJ45 Edge Switch

Broadcom QUMRAN 3GB

Arista 7010T 1G RJ45 Edge Switch

Broadcom Helix 4MB

Arista 7280QR 40G switch Broadcom JERICHO 4GB

Arista 7280SR 1/10G Switch Broadcom JERICHO 4GB

Arista 7280TR 1/10G RJ45 Switch Broadcom JERICHO 4GB

Arista 7050CX3 32 x 100G QSFP

2 x 10G SFP

Broadcom Trident 3 32MB

Arista 7050SX3 48 x 25G SFP

8 x 100G QSFP

Broadcom Trident 3 32MB

Arista 7050TX3 48 x 10G RJ45 8 x 100G QSFP

Broadcom Trident 3 32MB

Arista 7500R2 Chassis based Broadcom JERICHO+ 4-32GB

Arista 7280R2 Various models Broadcom JERICHO+ 4-32GB

Arista 7280R3 Various models Broadcom JERICHO2 4-32GB

Arista 7060xX2 Various models Broadcom Tomahawk+ 22MB

Arista 7260xX3 Various models Broadcom Tomahawk2 42MB

Arista 720 XP Various models Broadcom Trident 3 (X3)

8MB

HPE FlexFabric 5930-32QSFP+ 40G switch Broadcom Trident 2 12.2MB

HPE FlexFabric 5930 2QSFP+ 2 1/10G Switch

1/10G RJ45 Switch

Broadcom Trident 2 12.2MB

HPE Altoline 6900 1G RJ45 Edge Switch

Broadcom Helix 4MB

Juniper QFX5100-24Q-AFO 40G switch Broadcom Trident 2 12.2MB

Juniper QFX5100-48S-AFO 1/10G Switch

1/10G RJ45 Switch

Broadcom Trident 2 12.2MB

Juniper QFX5100-48T-AFO 1G RJ45 Edge Switch

Broadcom Trident 2 12.2MB

Juniper QFX5120-48Y(M) 1/10/25/40/100G Broadcom Trident 3 x5 32MB

Juniper QFX5120-48T 1/10 RJ-45 100G Switch

Broadcom Trident 3 x5 32MB

Juniper QFX5120-32C 100G Switch Broadcom Trident 3 x7 32MB

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 39 of 242

Juniper QFX5220-128C 100G Switch Broadcom Tomahawk 3

64MB

Juniper EX4400 1/10 RJ-45 25G Switch

Broadcom Trident 3 X3 8MB

NOT ALL OF THE ABOVE PRODUCTS HAVE BEEN TESTED AND APPROVED BY AVID, BUT ALL ARE CONSIDERED ARCHITECTURALLY CAPABLE. SEE section 1.6.1.2

1.6.1.2 IS QUALIFIED STILL REQUIRED MAY 2021: The need for formal QUALIFICATION of Switches (and NICs) with NEXIS is reduced significantly compared to (legacy) ISIS, also the quantity of devices reaching APPROVED status is reducing, as fewer companies are willing to pay for those stronger assurances, and this is offset by the quantity of network vendors using proven merchant silicon, and the evolution of those “silicon families”, the same principle applies to well-known custom silicon families. There is little to be gained from testing newer members of a proven “family”, that has evolved with greater capability than its successfully deployed predecessor. While there will always be a low risk with newer product families and software versions these have to be balanced against the resources consumed/purchased for testing. Added to this must be the complexity of networks that are being deployed, it is common for the companion applications such as Asset Management to be virtualised in a VM FARM on one switch pair (edge/leaf) and for the storage to be on a different switch pair (edge/leaf), and the Ingest & Playout or NLEs to be on yet a switch (edge/leaf). The concept of qualification does not work in such complex distributed environments. It is the lower speed (in comparison to NEXIS storage engine speed) edge devices that the most “demand” for sufficient edge buffering. Therefore, in those complex network deployments it is important to understand the path capabilities in combination with the desired workflows and apply the knowledge of previous successful (or problematic) implementations to make the appropriate judgement call for new projects. Of course, this applies to “fat” NEXIS clients, while for “thin” MCCUX clients the path requirements are minimal, and the edge device is of little concern. As can be seen many of the newer devices now listed in Section 1.6.1.1 exceed the capabilities of the switches mentioned at the beginning of section 1.6.1 (from Original V2.0 DEC 2017 release of this document). To use a car analogy (something I am well known for), don’t get corralled into the thinking that a newer 3.0L Engine cannot do what an older 2.0L engine could do……... of course, a modern 2.0L fuel injected engine can do twice what and older carburettor based 3.0L could, but that is just another example of how technology marches on and moves the goal posts too, and that is before we talk about electric cars (oops I better stop now!). You always have to understand the machine, and not be dazzled by the brochure.

1.6.2 Chassis Based Switch Families Many of the products above are also available as blades in chassis-based switch Nexus 9500 have “equivalents” in the Nexus 9300 family, but not direct equivalents as quantity of chips usually differ.

There are three families of Nexus 9500 First Generation are based around Trident 2 merchant silicon from Broadcom

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 40 of 242

Second Generation EX/FX series are based around LSE custom silicon from Cisco Both the first and second generation have Fabric cards I/O cards and fabrics CANNOT be mixed between generations Third Generation FX series are based around LS1800FX custom silicon from Cisco There is also a deep buffer variant of the NEXUS 9500 family which is designated 9500R. This has not been teste with NEXIS but should be amply capable. However, this deep buffer variant unexpectedly failed a test with ISIS 7x00 in 2018 probably due to a firmware bug in conjunction with the high fragmented UDP payload used by ISIS 7x00, which should not impact NEXIS which use a TCP Payload.

Arista 7500E have direct equivalents in the 7280SE family. Arista 7500R have direct equivalents in the 7280R family.

NOT ALL OF THE ABOVE PRODUCTS HAVE BEEN TESTED AND APPROVED BY AVID

9300/93000 Model CHIPSET BUFFER

NEXUS 95XX I/O

CARD ARCHITECTURE

9300/93000 Model CHIPSET BUFFER

NEXUS 95XX I/O

CARD ARCHITECTURE

N9K-C9372PX-E Trident2 + ALE 48-port 1/10 G SP+ 6 x 40G

N9K-X9564PX 48p 1G/10G SFP+ & 4p 40G QSFP

N9K-C9372TX -E Trident2 + ALE 96-port 1/10 G-T& 6 x 40G

N9K-X9564TX 48p 1G/10G Base-T ports & 4p 40G QSFP

Nexus 9332PQ Trident2 + ALE 32x 40G

Trident2 + ALE (x2) N9K-X9536PQ 36 port 40G QSFP+

Trident 2 only (x3) N9K-X9636PQ

36 port 40G QSFP+

Aggregation Module

Trident2 + ASE N9K-X9736PQ ACI SPINE MODE ONLY

Nexus 93120TX Trident2 + ALE 96-port 1/10 G-T& 6 x 40G (opt)

N9K-C9396PX TX Trident2 + ALE +GEM 48-port x1/10G & 12 x 40G or 4x100G

N9K-C93128TX Trident2 + ALE +GEM 96-port x1/10G & 8 x 40G or 2x100G

N9K-X9432C Flexible Speed 10,25,40,50,100G

N93180 YC-EX LSE 37.4MB (2x18.7)

48-port 1, 10 and 25 Gigabit Ethernet SFP+ with 6-port 100

Gigabit Ethernet QSFP+

LSE x 2 75MB (2x LSE) N9K-X97160 YC-EX

48-port 1, 10 and 25 Gigabit Ethernet SFP+ with 4-port 100

Gigabit Ethernet QSFP+

N93108TC-EX LSE 37.4MB (2x18.7)

N93180C-EX LSE 37.4MB (2x18.7)

LSE x 4 150 MB (37.4*4) N9K-X9732C-EX 32 x 100G 1:1

LSE x 4 150 MB (37.4*4) N9K-X97326-EX 36 x 100G 1.1:1

N93180LC-EX LSE 37.4MB (2x18.7)

24 x 40/50-Gbps Enhanced QSFP (QSFP+) ports and 6 x 40/100-

Gbps QSFP28 ports

N93180YC-FX LS1800FX 40.8MB (1x 40.8)

N93108TC-FX LS1800FX 40.8MB (1x 40.8)

LS1800FX x 2 81.6 MB (40.8 x2) N9K-X9788TC-FX

48-port 1 and 10GBASE-T plus 4-port 40/100 Gigabit Ethernet

QSFP28

N9348GC-FXP LS1800FX 40.8MB (1x 40.8)

N9336FX2 LS3600 FX2 40MB (2x20) 32 100G (2x50, 1x40, 4x25, 4x10)

LS1800FX x 4 163.2 MB (40.8 x4) N9K-X9732C-FX

Every QSFP28 supports 1 x 100, 2 x 50, 1 x 40, 4 x 25, 4 x 10,

and 1x1/10 Gigabit Ethernet

LS1800FX x 4 163.2 MB (40.8 x4) N9K-X9736C-FX

Every QSFP28 supports 1 x 100, 2 x 50, 1 x 40, 4 x 25, 4 x 10,

and 1x1/10 Gigabit Ethernet

N9364C S6400 40.8MB (4 x10.2)

64 x 100G 2U 100G/50G/40G/10G (single port mode

100G/50G/40G/10G (single port mode 100G/50G/40G/10G no

breakout)

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 41 of 242

SEE section 1.6.1.2

1.7 Cisco Catalyst Switches This section discusses the suitability, or not of Catalyst switches that have not been tested directly by Avid.

1.7.1 Catalyst 9000 - A series Applies to Catalyst 9300 (C9300), Catalyst 9400 (C9400), Catalyst 9500 (C9500). These devices are not a supported or approved switch. In January 2018 Cisco shared with Avid some results of simulated data packet testing (Avid defined data flows) on the C9300-24UX and the C9500-40X, no results are available on the C9300 24T/48T (or P/U variants), but they are likely to perform worse.

SEE SECTION 1.7.2 for Catalyst 9300 B series

With the default settings, both of these models dropped packets with a dual 10G source (both staggered and non-staggered), and a single 10G sources. The default setting does not allow sufficient buffer depth for the packet stream from storage engine to NLE Client. Applying a new single class of QoS profile with a deeper buffer configuration allowed the simulated packet stream testing to be successful for a limited number of clients, in specific port groups, during the simulated test, but this has not been tested with NEXIS clients.

PID – C9300 – 24UX (Added QoS Config) Switch(config)#qos queue-softmax-multiplier 1200

Switch(config)#policy-map All

Switch(config-pmap)#class class-default

Switch(config-pmap-c)#bandwidth percent 100

Switch(config-pmap-c)#

Switch(config)#int ra te1/0/1-24

Switch(config-if-range)#service-policy output All

The C9300-24UX and the C9500-40X with 1G client ports and two 10G source ports could support up to 8 clients in the simulated test emulating two 512KB chunks, and not using the ports sequentially (this maximizes the capability of the architecture and is more akin to the statistical spread of port usage during normal operations). This test used 24 Active receiver ports. This is probably a good indication of the ability to support 16 x dual-stream NLE with a 50Mbit/s codec. This would likely double with a 48-port device which has additional ASICs and hence additional buffering. With a lower active port count of 16 the C9500-40X, with 1G client ports and two 10G source ports could support up to 16 clients in the simulated test emulating two 512KB chunks, and not using the ports sequentially (this maximizes the capability of the architecture and is more akin to the statistical spread of port usage during normal operations). This is probably a good indication of the ability to support 32 x dual-stream NLE with a 100Mbit/s codec. However, the C9500X is really not targeted as device for 1G client connection, which is really the target market for the C9300.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 42 of 242

It should be noted at the time of writing (JAN2018 updated MAR 2019) this device has not been tested directly with NEXIS storage and NLE clients. It is recommended not to deploy this for use with NEXIS storage and NEXIS clients.

1.7.2 Catalyst 9000 - B series Applies to Catalyst 9300B models listed below. C9300-24UB C9300-48UB C9300-24UXB Following Vendor testing in 2019 this product has been marked as Architecturally Capable in JAN 2020. As with all use of Architecturally Capable products deployed. Of course, this is not carte blanche, for Vendor or Customers, there is still a lot of work to do, and lessons to learn. The risks remain with the customer and Vendor for solution using this product until a funded approval is done with Avid professional services, also a funded approval may only get limited approval depending on the workflows and deployment scenario. 1.7.2.2 SOFTMAX CONFIGURATION DETAILS for Cisco Catalyst C9300B series It is necessary to modify the default buffer configuration which is not deep enough for correct operation. This product has double the buffer of the first series of Catalyst 9000, which was found to be insufficiently capable during simulated testing. First Generation Cisco Catalyst C9300 series are not considered Architecturally capable. The command below provides the basic commands and port numbers that should be used. If using a stacked configuration, the port numbers will have to be modified accordingly. C9300-24UB Switch(config)# qos queue-softmax-multiplier 1200

Switch(config)# policy-map ALLPORTS

Switch(config-pmap)# class class-default

Switch(config-pmap-c)# bandwidth percent 100

Switch(config-pmap-c)# queue-buffers ratio 100

Switch(config)#int ra G1/0/1-24

Switch(config-if-range)#service-policy output ALLPORTS !!>> Release Hard MAX buffers Switch(config)#int ra T1/1/1-8

Switch(config-if-range)#service-policy output ALLPORTS !!>> Release Hard MAX buffers Switch(config)#qos stack-buffer disable

qos queue-softmax-multiplier 1200

policy-map ALLPORTS

class class-default

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 43 of 242

bandwidth percent 100

queue-buffers ratio 100

!

int range G1/0/1-48

service-policy output ALLPORTS

!

int range T1/1/1-8

service-policy output ALLPORTS

qos stack-buffer disable

!

C9300-48UB Switch(config)# qos queue-softmax-multiplier 1200

Switch(config)# policy-map ALLPORTS

Switch(config-pmap)# class class-default

Switch(config-pmap-c)# bandwidth percent 100

Switch(config-pmap-c)# queue-buffers ratio 100

Switch(config)#int ra G1/0/1-48

Switch(config-if-range)#service-policy output ALLPORTS !!>> Release Hard MAX buffers Switch(config)#int ra T1/1/1-8

Switch(config-if-range)#service-policy output ALLPORTS !!>> Release Hard MAX buffers Switch(config)#qos stack-buffer disable

C9300-24UXB

Switch(config)# qos queue-softmax-multiplier 1200

Switch(config)# policy-map ALLPORTS

Switch(config-pmap)# class class-default

Switch(config-pmap-c)# bandwidth percent 100

Switch(config-pmap-c)# queue-buffers ratio 100

Switch(config)#int ra Ten1/0/1-24

Switch(config-if-range)#service-policy output ALLPORTS. !!>> Release Hard MAX buffers

Switch(config)#int ra T1/1/1-8

Switch(config-if-range)#service-policy output ALLPORTS. !!>> Release Hard MAX buffers

qos queue-softmax-multiplier 1200

policy-map ALLPORTS

class class-default

bandwidth percent 100

queue-buffers ratio 100

!

int range Ten1/0/1-24

service-policy output ALLPORTS

!

int range T1/1/1-8

service-policy output ALLPORTS

qos stack-buffer disable

!

1.7.3 Catalyst 9000 - B series – USING SOFTMAX ONLY Funded customer testing In SEP 2020 revealed many nuances of the C9300UB series. The point to make clear is that SoftMax is the key command to successful buffers depth for use with NEXIS clients. However, it must also be understood that the impact of this command in a C9300

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 44 of 242

stackable device stays withing the stackable device, but in a C9400 chassis-based switch the buffers are more thinly spread as there are a great many more ports, but there are also 3 ASICS (and hence 6 cores) Hence it may be feasible to adopt a 3-stage buffer optimization to prevent packet discard

1. qos queue-softmax-multiplier 1200 a. if not discarding stop here

2. apply QoS tuning a. if not discarding stop here

3. qos stack-buffer disable a. to gain the extra buffer pool, but does not affect buffer depth capability for an

individual port

Assuming it is a number of bytes per buffer cell is 256 bytes, that means a UDP 2.0 XL device has the following buffer depths below.

The Testing with 9300B platform confirms that ONLY the SoftMax multiplier setting (step 1 above) should be required in 99% of expected workflows, the additional command listed above in steps 2 and 3 are unlikely to be required.

1.8 Network Interface Cards This may not be a large subsection, initially anyway, as the needs of NEXIS differ significantly from those of ISIS7500. The NIC implementation for NEXIS does not have to be as capable, because NEXIS is not sending large, fragmented datagrams, as we did with ISIS 7500 which mandated the requirement of “server class” NICs. But there are always special cases that might need something a little different. Additionally, the needs of virtual machines and blade servers and Fabrics bring new challenges to the “old order”.

1.8.1 Single-mode vs. Multi-mode There are lots of articles on the web about the difference between Single-mode vs. Multi-mode fibre, so this large topic will not be covered in any detail. Suffice to say that Single mode is more

UADP 2.0 XL UADP 2.0

256 bytes KBYTES MBYTES MBYTES

400 HARDMAX = 102400 100 0.10 0.05

1600 SOFTMAX = 409600 400 0.39 0.20

12x..1200 19200 SOFTMAX = 4915200 4800 4.69 4.79 2.34 2.39

28800 SOFTMAX = 7372800 7200 7.03 3.52

100% Q0 40000 SOFTMAX = 10240000 10000 9.77 9.86 4.88 4.93

PER CORE PER CORE

10 EGRESS 5

3.25 STACK 1.25

13.25 (MB) 6.25

1.25 INGRESS 1

1.5 HOLDING 0.75

2.75 (MB) 1.75

16 (MB) 8

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 45 of 242

expensive and more capable of greater distance and speed, but Multi-mode is sufficient for most tasks of less than 100 metres. However, many large data centres are now deploying single mode only to have better longevity of investment, and “protection” for future technologies. But most ACR in the media world still used Multi-mode within a building and Single-mode between buildings. I have not yet seen a native Mono-mode/Single mode 1G optical NIC, and I didn’t understand why one would be needed, but there are always opportunities to learn. Based on traditional deployments of Avid storage, the Intel I350F would be the natural choice but is MMF, and as the URL below indicates it is “Intel inside” so I see no issue http://www.silicom-usa.com/pr/server-adapters/networking-adapters/gigabit-ethernet-networking-server-adapters/pe2g2sfpi35-server-adapter/ I thank a customer for bringing this NIC to our attention, and SFP based NIC of this calibre is a good find. Looking elsewhere of their site they have some really interesting products.

1.8.2 USB-C NIC Information Here are the USB-C to 1 Gb Ethernet devices tested on the Windows based laptops most recently [MAR 2018]: Dell DA-200 Dell DBQBCBC064 Belkin F2CU040 These were tested using read, write, and mixed workflows both with ABU, PATHDIAG, and Media Composer. As mentioned, there was an intermittent issue, with ABU only, that turned out to have nothing to do with the adapters. It had to do with the retry logic, in the reporting back from the benchmark agent to the system running ABU. There is a work-around for this issue until we get a fix, but requires the presence of a 2nd NIC to dedicate as the ABU reporting NIC. This is more of a corner case for test purposes.

1.8.3 NICs in a VM environment – applies to bare metal too Hardware for Virtual machines cause an interesting challenge for Avid applications, on many levels. When Avid sold the server and client hardware alongside the application, we could control the choice of CPU and NIC etc., and that was reasonably important in ISIS 7500/5500 deployments, which have “special needs” driving the requirement for specific NICs to use driven by the use of fragmented UDP data transport to 1G clients, which negated the need to use TCP offload cards which when ISIS 7500 was designed were approx. $1000 each (a good idea in 2005 when UNITY ISIS was launched). With ISIS 10G clients (from 2010 using the Myricom NIC) TCP was used as the primary transport method at 10G and then from ISIS V4.7 it was used at 1G on ISIS 5500 too. With the advent of NEXIS, the “special needs” are largely eliminated both 10G and 1G clients. The NEXIS platform uses TCP for ALL primary data transport and only a little bit of fragmented UDP (small fragments) for our “OTT” signalling protocols. So, in A NEXIS world, most NICS will work fine, but some will be better than others in the performance stakes. Also, NEXIS clients can survive in with less edge buffering and even a low percentage of packet discard will not cause frame drop, because we use TCP with FRR instead of Fragmented UDP as with ISIS 7x00.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 46 of 242

Note: To This principle can also be applied to NLE, most Enterprise class NICs will operate successfully as satisfy most workflows, but some will perform better than others high demand workflows.

Note: The NIC is of much less importance in NEXIS than ISIS. Some NICs will always perform better than others depending on platform specifics, but maximum performance is not the only criterion, good performance with stability is key. Also consider that virtualization abstracts the REAL NIC too. Avid chose Myricom 10G NIC for use with ISIS in 2010 (to replace the L2 only Chelsio card)……. for 2 reasons 1. It worked with ISIS 7x00 (there was no 5x00/2x00 at the time) 2. It had drivers for Windows and MAC. (Linux at the time was not a consideration).…. Something which Intel 10G NICs did not have, even though Intel was favoured for 1G operation with ISIS. Hence it was a “good’ choice for high bandwidth application such as COPY/MOVE server, and UHRC NLE (Windows and MAC). In the early 2010s Broadcom improved its NIC offerings for servers and workstations; and in some servers Avid started to use the BCM57800 0G NIC in some servers as the Interplay engineering and the Storage engineering started to use different criteria, partly due to the move away from AS3000 servers to Dell R630 in 2015, also for some time many customers had been purchasing HP DL360. When virtualisation is added to the mix the brand becomes even less relevant, as the virtual NIC is abstracted from the REAL NIC, the on top of virtualisation we had varying levels of convergence. While Myricom 10G NIC was the “default” choice due to the legacy elements I have explained above, it was never selected because of special characteristics for Interplay/ MediaCentral applications.

That “historical ability” with 3rd party hardware is largely removed, as we move into a Virtual machine world (and this could mean Cloud too where there is ZERO ability to specify specific NIC vendors), the ability to control hardware is massively reduced, plus the adapter presented is a Virtual NIC anyway, regardless of the real hardware which is being shared with other VMs, and possibly non-avid applications. Also consider that some of the NICs recommended by Avid the past when working in “known tin” (e.g. HP DL360 or Dell R630) do not work well in a virtual environment. Avid can only test a limited number of variations, and of key products it might sell or those encountered on extremely large projects, but the silicon at the heart of most NICS are made by a small number of providers, yes there will always be the specialists and innovators at the leading edge of technology, but the bulk of NICs come from the few “foundries”. Also, many of the Server

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 47 of 242

manufactures re-brand (badge-engineer) well known NIC vendors’ products although use different model numbers for the same basic chipset, but they are not completely open about such facts unless one goes digging for the specifics. The primary vendors of Server class NICS should all do a good job for Avid applications that interfaces with Avid NEXIS storage. The extract from Interplay documentation below suggests that Qlogic (Broadcom) and Mellanox are acceptable, but some older adapters should be avoided. This does not mean ALL Intel NICS should be avoided, the X520 is a particularly old one, and Avid would probably not attempt with the later X710 as this does not come as standard in the server hardware for VM based solution that we have worked with. From Avid Interplay | Production V2017.2 Documentation

Interplay® | Production Virtual Environment with VMware® Best Practices Guide Version 3.3 and later December, 2017 http://resources.avid.com/SupportFiles/attach/Interplay_Virtualization_Best_Practices.pdf

Network Adapters The following network adapters are qualified and recommended: • QLogic 57800, 57810, 578x0 (includes the 57840), QLE3442 (not for iSCSI), QLE8442 • Mellanox ConnectX 3 • Cisco UCS VIC 1340 (or 13x0) plus UCS 2208XP Fabric Extenders The following network adapters are not supported: • Intel X520 • Myricom Myri-10G

The Avid NEXIS 2018.3 README Client is supported with VMWare ESXi v6.0.0 (Update 1) using a VMXNET3 adapter with the Mellanox ConnectX-3 adapter and the Mellanox ESX OFED Driver version 1.9.10.2 or later. Also consider that NEXIS controller uses Mellanox ConnectX-3 adapter, so I would not expect any conflict with Mellanox ConnectX-4, ConnectX-5 (or later series), that you might find in a server used for Virtual machine hosting. The goal posts are forever moving, QLogic 57800 was a 10G NIC architecture, but I cannot fine details of 40G product in this series. But there is QLogic FastLinQ QL4541xHLCU 40GbE Intelligent Ethernet Adapters. But 40G is an aging technology fast being replaced by 25/50/100G products such as there are new adapters from QLogic: QLogic QL45000 25Gb and 50Gb Flex Ethernet Adapters (QL45214, QL45212 and QL45262) and also QLogic FastLinQ QL45611HLCU Single-Port 100G Intelligent Ethernet Adapter Plus new “names” enter fray, in August 16, 2016 Cavium™ Completed Acquisition of QLogic. In April 2021 I was advised of successful deployment of Mellanox ConnectX5 100G NIC is a Dell VM server hosting virtual Media Composers. While this section (and Avid) cannot give a “carte blanche” for any NIC vendor to be used, we can look at product families that have worked well before and consider their evolutions in a favourable

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 48 of 242

light until there is hard evidence of something that is broken and/or will not work, that can be documented. If in doubt, contact Avid and we will do our best to at least provide a judgement call on the suggested devices.

1.8.4 10GBASET Transceivers While 10GBASE-T (or 10GBASET) exists as a standard since 2006, there are certain challenges with deployment when using plug in transceivers, this is due to the limited power budget in the SFP enclosure which does not allow a 100M connection. This means that plug in 10Gbase-T transceivers are limited to 30M, not the full 100M of the published standards. Many switch vendors do not supply a standard 10GBASE-T part, but there are 3rd party suppliers that do supply parts and also offer “guaranteed compatibility” with several vendors. Some possible suppliers are given below (price & quality will vary): https://www.flexoptix.net/en/ https://portal.prooptix.se/en/sfp/3805-sfp-10g-t-p-cisco-sfp www.prolabs.com https://www.fs.com/uk/products/66612.html www.10GTek.com (also available on Amazon) www.startech.com www.switchsfp.com 1.8.4.1 Nexus 93180 YC-EX SWITCH using SFP 10GBaseT In a project engagement in NOV 2018 10G Copper RJ45 transceivers were used are from 10Gtek. T connect with a Broadcom BCM 57412 LoM implementation in a DELL servers. These were later removed and replaced by Cisco 1-G SP transceivers as add-in SFP28 BCM 57412 based cards were deployed. Broadcom 57412 25G/10G NICS are not an officially approved part but exceed the capabilities of the approved BCM5800 based 10G NIC.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 49 of 242

They show up as: type is 10Gbase-SR name is OEM as shown below even though there are not 10Gbase-SR, but 10GBaseT. Ethernet1/13 transceiver is present type is 10Gbase-SR name is OEM part number is SFP-10G-SR revision is 02 serial number is CSSSRI90012 nominal bitrate is 10300 MBit/sec Link length supported for 50/125um OM2 fiber is 82 m Link length supported for 62.5/125um fiber is 26 m Link length supported for 50/125um OM3 fiber is 300 m cisco id is 3 cisco extended id number is 4

There was no time to really test these devices as SFP+ Based 10G optical NICS were provide on 21 NOV 18. However there appears to be no performance issues. Reliable information from the switch with regard to interface use/errors was not available because there were frequent changes and no real data test were done with these transceivers and the copper integrated NIC ports.

1.8.5 I350-T2 NIC Eol – Replaced by I350T2V2 ORGINALLY section 1.6.7.1 in NETREQS V1.x The Intel I350T2 NIC (launch date Q2-2011) has been revised, the replacement is the I350- T2V2 was launched Q3-2014, but the core controller is still the I350.

Reason for Revision: Incorrect Replacement MM# The Intel® Ethernet Server Adapter I350-T2 and Intel® Ethernet Server Adapter I350-T4 will undergo the following changes: 1. Existing Product is being EOLed to be replaced with new versions which have the AUX Power component changes that will result in a decrease of in-rush current during power supply start-up. Product functionality does not change.

https://qdms.intel.com/dm/i.aspx/B3EAA66A-ED91-4822-AE37-29781EC0930D/PCN113232-01.pdf Date of Publication: September 24, 2014 Key Characteristics of the Change: Product Discontinuance Forecasted Key Milestones: Last Product Discontinuance Order Date: Feb 14, 2015 Last Product Discontinuance Shipment Date: Aug 14, 2015 http://ark.intel.com/products/59062/Intel-Ethernet-Server-Adapter-I350-T2

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 50 of 242

http://ark.intel.com/products/84804/Intel-Ethernet-Server-Adapter-I350-T2V2 [ LINKS ACTIVE MAY 2019]

1.8.6 Architecturally Capable NIC Chipsets Taken form (SEP2021) https://avid.secure.force.com/pkb/articles/en_US/Compatibility/Avid-NEXIS-Network-Switch-Infrastructure

Architecturally Capable NIC Chipsets

NIC or CHIPSET VENDOR PRODUCT FAMILY NOTES

CAPABILITY GRADE

Intel X710 PCIe v3.0 x8 10G 3

Intel X550 PCIe v3.0 x8 10G 3

Intel X540 PCIe v2.1 x8 10G 3

Broadcom BCM578xx PCIe v2.1 x8 10G 3

Broadcom BCM574xx PCIe v3.0 x8 10/25G 3

Mellanox ConnextX3 ConnextX3 10/40G N/A*

Mellanox ConnectX4 ConnectX4 PCIe3.0 x8 40/50G N/A*

Mellanox ConnectX4 ConnectX4 PCIe3.0 x16 40/50/100G

Mellanox ConnectX5 ConnectX5 PCIe3.0 x16 100G N/A*

Mellanox ConnectX5 ConnectX5 PCIe4.0 x16 100G

* These devices are considered suitable for application servers, not NLE.

1.8.7 Known Vendor NIC Chipsets

NIC VENDOR & MODEL PRODUCT FAMILY NOTES CAPABILITY GRADE

HPE Ethernet 10Gb 2-port 562SFP+ Adapter Intel X710

Existing successful deployments PCIe v3.0 x8 10G https://support.hpe.com/hpesc/public/docDisplay?docId=emr_na-c05058145

3

1.9 Airspeed 5500 (3rd GENERATION) network connection With the changes in the connectivity standards of the newest generation of Airspeed 5500 now with Windows 10 we are encouraging installations to simplify the Installations by using only the 10g interfaces, the reason is that we are unable to support the i217 built in ethernet port as it causes system stability issues, while the i210 built-in ethernet port works flawlessly, this presents a problem for clients interested in dual connections as they are required to use at least one of the 10g ports on the system, though this fact we would offer use of the low cost SFP+ 1G media adaptor from Finisar be used for both 10G ports abandoning the single i210 network adaptor in favour of higher performance network interfaces.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 51 of 242

Avid tested native 10G interface link (with NEXIS storage, but not the EoL ISIS 7500 or ISIS 5500) with no issues in both dual link AvidFOS configuration and teaming enabled for link fault tolerance, below you will find the cable Selection that we are able to support, additional cables and adaptors are also possible however Avid would be unable to provide trouble shooting on additional interface modules. Twinax for 10GbE Dell Direct Attach 10G Cable. Copper 10GbE SFP+ twinax cable, 1 meter (AVID PART NUMBER 7070-30615-01) Dell Direct Attach 10G Cable. Copper 10GbE SFP+ twinax cable, 3 meter (AVID PART NUMBER 7070-30615-03) Cisco 10G SFP+ direct attach cable (twinax) 1 meter (AVID PART NUMBER 7070-30358-01) Cisco 10G SFP+ direct attach cable (twinax) 3 meter (AVID PART NUMBER 7070-30358-03) Cisco 10G SFP+ direct attach cable (twinax) 5 meter (AVID PART NUMBER 7070-30358-05) SFP+ 10 GbE optical transceivers. Mellanox SFP+ 10 GbE SR optical transceiver. 10GbE Ethernet SFP+ LC 300m range, SR 850nm wavelength (AVID PART NUMBER 9900-65632-00) Mellanox SFP+ 10 GbE LR optical 10Gbps transceiver. 10GbE Ethernet SFP+ LC 10km range, LR 1310nm wavelength (AVID PART NUMBER 9900-65652-00) JDSU plrxpl-sc-s43-22-n - 10GBase SR LC, 300 meters, 850 nm SFP+ transceiver < Tested SFP+ 1GbE media adaptors Finisar's FCLF8520P2BTL, FCLF8521P2BTL and FCLF8522P2BTL 1000BASE-T Copper < Tested FINISAR DATA SHEET

https://www.finisar.com/sites/default/files/downloads/finisar_fclf852xp2btl_1000base-t_rohs_compliant_copper_sfp_transceiver_product_specification_0.pdf

Finisar’s FCLF8520P2BTL, FCLF8521P2BTL and FCLF8522P2BTL 1000BASE-T Copper Small Form Pluggable (SFP) transceivers are based on the SFP Multi Source Agreement (MSA). They are compatible with the Gigabit Ethernet and 1000BASE-T standards as specified in IEEE Std 802.32. The transceiver is RoHS compliant and per Directive 2011/65/EU3 and Finisar Application Note AN-2038. The 1000BASE-T physical layer IC (PHY) can be accessed via I2C, allowing access to all PHY settings and features.

The FCLF8520P2BTL uses the SFP’s RX_LOS pin for link indication, and 1000BASE-X auto-negotiation should be disabled on the host system. The FCLF8521P2BTL is compatible with 1000BASE-X auto-negotiation, but does not have a link indication feature (RX_LOS is internally grounded). See AN-2036, “Frequently Asked Questions Regarding Finisar’s 1000BASE-T SFPs”, for a more complete explanation on the differences between the two models and details on applications issues for the products. The FCLF8522 shall support both RX_LOS pin for link indication and 1000BASE-X auto-negotiation.

A typical price for this device I approximately USD $100 depending on purchased quantity (at time of writing this section in MAY 2018)

1.10 NAT/PAT Incompatibility Not many folks have attempted this, those that have failed to get it working successfully.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 52 of 242

The NEXIS client is not designed to be used with Network Address Translation or Port Address Translation (as at OCT 2019), and as currently deployed the NEXIS solution is fundamentally incompatible with such techniques. Recent encounters (Q3/2019) with a LINUX VM based solution that tried to do this has bought this issue to the fore. The used of NAT/PAT/NPAT has never been supported in any ISIS 7x00/5x00/2x00 solution that preceded NEXIS.

1.10.1 Kubernetes – the “core” of the “network” problem with MCCUX The MediaCentral Cloud UX particular issue with NEXIS (site was using FS 2019.6, but that is incidental to the issue) that caused the hardship on this deployment with a VM based design was down to a bit of bad luck in the choice of IP subnets.

The problem was that the Nexis ("172.19.126.10;172.19.126.12") is in the default Kubernetes virtual network range (172.19.0.1/16). During installation, it is needed to define a Kubernetes network range which does not conflict with any other network which provides servers/services which are needed by CloudUX. The Kubernetes network range can be defined during the initial/first installation as part of the “avidctl platform host-setup” step. Changing at a later point is in principle possible but difficult. For example, it was not able to fix this particular test system – a new installation was required. Here is internal documentation of how to change the Kubernetes network after installation https://avid-ondemand.atlassian.net/wiki/spaces/PFENG/pages/1679425701/Platform+Service+Host+Troubleshooting+-+Change+Kubernetes+Internal+Network

Hence has the customer chosen 10.x.y.z or 192.168.y.z or any 172.16.y.z (except for 172.19.0.0/16) this problem would not have occurred . This problem manifested itself in such a way as to “blame” the network path because packets were getting “dropped,” but it was not the “fault of the network switches. Yes, it is a network path issue but in the “last metre”, other Windows VMs worked fine. Below are some more fine details taken from Avid internal systems that adds the necessary “colour” to the challenge encountered by CS & Engineering in diagnosing the customer issue.

NEXIS Linux client connects to System Director and has functioning file metadata services, but TCP data transfer to and from the Storage Managers fails. Small reads and writes (which are piggybacked as “immediates” in the UDP control packets) succeed correctly.

The problem here is address translation (after all), albeit in a strict and subtle sense: Addresses are not getting translated, but TCP ports are. NEXIS does not function with address translation (even if only for ports).

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 53 of 242

A log snippet exemplifies the issue. The client commands and successfully makes a connection on (it thinks) its TCP port 50093, but port translation encapsulated beneath the NEXIS components causes the actual connection to be made on TCP port 12476. The client then sends a read request to the server, specifying target port 50093, the one upon which it had just commanded the connection, but the server cannot find that (address, port) tuple in its destination table, so it rejects the request with an FSTATUS_NO_CONNECTION error.

Another network range to Avoid according to MCCUX documentation is

From MCUX Install Guide (page number depends on doc version) Kubernetes Networking Options. During the deployment process, the script defines two internal networks that are used by Kubernetes for internal communication: - Kubernetes Service Network: The default range of this network is 10.254.1.0/24. - Kubernetes Pod Network: The default range of this network is 172.19.0.1/16.

RECENT FIELD INFORMATION DEC 2020 also suggests…….. - Docker0 172.17.0.0/16 *(not documented)

Thankfully 10.254.x.x is a rarely used range, which when used is likely to be for point-to-point /32 links. Still one to be wary of when “unexplained” problems occur. FIELD KNOWLEDGE: In Jan 2021 there was an another “incident” resulting in “IP conflicts and MCCUX Server. A customer was using a 172.17.248.0/22 as their range for their VPN incoming devices into the Network range 10.61.191.0/24 for MediaCentral. The MediaCentral Production elements could communicate successfully with the VPN clients, but the VPN clients could not communicate with MCCUX server. The resolution was to change the internal IP ranges used within the MCCUX Cocker/Kubernetes environment. This URL may help find out what is in use. https://www.lullabot.com/articles/fixing-docker-and-vpn-ip-address-conflicts

1.10.2 MCCUX “Kubernetes” – NO LONGER USING MULTICAST Media Central Cloud UX Server Kubernetes does not use multicast. Keepalived is configured to use unicast by default (multicast configurations are not supported). Media Central Cloud UX V2018.1 initial release AUG 2018.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 54 of 242

2.0 NETWORK DESIGNS FOR NEXIS There are no qualified network designs in the “Avid® NEXIS® Network and Switch Guide July 2017”.

Most designs that work for ISIS 7x00 will work for NEXIS. Some Designs for ISIS 5x00 will work for NEXIS. Other network designs need to be approved. Avid network consultants have experience of many successful network deployments, plus they have learned some valuable lessons from some deployments which encounters a few challenges. This section provides basic detail on known successful deployments. Some of these products may not yet have achieved formal approval but might have been tested as part of custom funded testing. The designs may not show the precise type of quantity of NEXIS engines, this is deliberate to decrease the complexity of the drawing. There are some Vanilla Configs available at the same URL as this document. The feature some Visio diagrams and VPC enabled config files for Nexus 5600 and Nexus 9300, and a VSS config for C4500X.

2.1 Reference designs At the same URL as this document there are some block design concepts; these are deliberately not product specific. It should be possible to use the formally approved products in these roles as shown below. Single switch designs will not be shown. Below is an example design complex design with qualified switches.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 55 of 242

Figure 1 – Reference design for NEXIS with DELL

2.2 Block based designs Most network solutions with resilience for NEXIS follow a common design concept, but they will vary in scale. The diagrams below in this section give some suggestions. Sometimes it is best to think of these necessary elements as Lego; some blocks are bigger than others, and some smaller blocks may be used repeatedly, for example there might be 8 edge switches and two core switches. These block designs can be used with any of the qualified, approved or architecturally capable switches in the core and edge combinations. There may be 6 engines not 2 as shown, there may be 4 edge switches not 2 and shown. Think of the diagrams below as foundational building blocks, not limited designs. There is no consideration for routed uplinks in the block-based designs below.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 56 of 242

2.2.1 The Traditional/Legacy way Two core switches, FHRP, Spanning tree

Figure 2 – Traditional Block design for NEXIS

Note: HSRP style C4500X implementations deployed for use with ISIS 7x00 offer partial reliance for use with NEXIS, for full resilience with NEXIS an VSS must be used and this will require downtime to convert between from HSRP to VSS. Probably better to deploy a new MLAG capable pair of switches. Avid PS NETWORK CONSULTANCY RECOMMENDED.

CORE SWITCH CORE SWITCH

EDGE SWITCH EDGE SWITCH

STORAGE ENGINE

STORAGE ENGINE

FHRP

RSTP

LACP

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 57 of 242

2.2.2 MLAG/vPC/VSS Single Controller Two core switches…So what’s changed? MLAG/vPC/VSS/VLT LACP instead of STP. Basic connectivity concept is little changed. When the aggregate connection is distributed across two switches, they must be a coordinated MLAG pair, hence any of the technique found in the URL below should be viable. Explicit Avid internal testing has only been done with Cisco VPC, Cisco VSS and Dell VLT. Other vendors deployments have been successful on Juniper and Arista. https://en.wikipedia.org/wiki/MC-LAG

MLAG designs should use a minimum of 2 x 40G (ideally TWINAX) PEER CONNECTION (for C4500X-VSS 4 x 10G) and a resilient PEER KEEP ALIVE (dual 1G or if dual 1G not available dual 10G TWINAX)

Figure 3 – MLAG/VSS Block design for NEXIS

CORE SWITCH CORE SWITCH

EDGE SWITCH EDGE SWITCH

STORAGE ENGINE

STORAGE ENGINE

MLAG/vPC/VSS

LACP

LACP

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 58 of 242

2.2.3 MLAG/vPC/VSS DUAL CONTROLLER More Resilience Dual controllers with LACP Basic connectivity concept is little changed

MLAG designs should use a minimum of 2 x 40G (ideally TWINAX) PEER CONNECTION (for C4500X-VSS 4 x 10G) and a resilient PEER KEEP ALIVE (dual 1G or if dual 1G not available dual 10G TWINAX)

Figure 4 – MLAG/VSS Block design for NEXIS with dual controllers

CORE SWITCH CORE SWITCH

EDGE SWITCH EDGE SWITCH

STORAGE ENGINE

STORAGE ENGINE

MLAG/vPC/VSS

LACP

LACP

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 59 of 242

2.2.4 STACKED SWITCH with DUAL CONTROLLER Stacked switch - VSS is similar Switches appear as “modules” SW1 T1/1 >> T1/1/1 SW2 T1/1 >> T2/1/1 Basic connectivity concept is little changed

Figure 5 – Stacked Block design for NEXIS with dual controllers

2.3 CISCO - Custom/Deployed designs This section provides detail of successful deployments that have been implemented with some element of funded testing attached, using Cisco products.

STACKED CORE SWITCH

STACKED CORE SWITCH

EDGE SWITCH EDGE SWITCH

STORAGE ENGINE

STORAGE ENGINE

MLAG LACP

LACP

LACP

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 60 of 242

2.3.1 Cisco Nexus 5600 Based 2.3.1.1 Cisco Nexus 5672 with Nexus 2248TPE FEX This is an approved/deployed design

Figure 6 – Custom design for NEXIS with Cisco Nexus 5600

2.3.1.2 Cisco Nexus 5672 with Nexus 2348UPQ FEX and N2248TPE This is an approved/deployed design. This solution is similar to the above and hosts both NEXIS and ISIS 7500. The NEXUS 5672 connects to the ISIS 7500. The subordinate Nexus 2348 UPC FEX connect

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 61 of 242

to the 10G NEXIS E4 Engines, and also hosts a VM farm for Interplay. The subordinate Nexus 2248TPE is used to connect NLE clients. The FEXs uplink to the parent switch i.e. the N5672.

Figure 7 – Custom design for NEXIS and ISIS 7500 with Cisco Nexus 5600

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 62 of 242

2.3.2 Cisco Nexus 9500 Cases 2.3.2.1 Cisco Nexus 9500 with Nexus N93108TC CISCO NEXUS 9500 FABRIC N9K-C9504-FM-E I/O N9K-X97160YC-EX I/O N9K-X9732C-EX

Figure 8 – Custom design for NEXIS with Cisco Nexus 9500/93000

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 63 of 242

2.3.2.2 Cisco Nexus 9500 EX with Nexus N93180 YC EX APRIL 2018

SERVER EDGE LAYER 2 CORE LAYER 3 CLIENT EDGE LAYER 2

N93180-YC-EX N9500 EX

N9K-C9508-FM-E

N9K-X9736C-EX

N93180-YC-EX

The solution performed as expected in terms of supporting the video load with no errors.

Correct operation was observed with ISIS 7500 storage and clients for video and PATHDIAG

Correct operation was observed with ISIS 5500 storage and clients for video and PATHDIAG

Correct operation was observed with NEXIS storage and clients for video and PATHDIAG

This testing was done with a small number of clients and storage engines so does not represent full load testing, but does reflect operational capability. 2.3.2.3 Cisco Nexus 9500 R with Nexus N93180 YC EX APRIL 2018

SERVER EDGE LAYER 2 CORE LAYER 3 CLIENT EDGE LAYER 2

N93180-YC-EX N9500 R

N9K-C9508-FM-R

N9K-X9636C-R

N93180-YC-EX

The solution performed as expected in terms of supporting the video load with no errors.

Correct operation was NOT OBSERVED with ISIS 7500 storage and clients for video but was observed for PATHDIAG

Correct operation was observed with ISIS 5500 storage and clients for video and PATHDIAG

Correct operation was observed with NEXIS storage and clients for video and PATHDIAG

This testing was done with a small number of clients and storage engines so does not represent full load testing, but does reflect operational capability.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 64 of 242

2.3.3 Cisco Nexus 93000 Cases 2.3.3.1 Cisco Nexus 9336C with Nexus N93108TC and/or 9348GC

Figure 9 – Custom design for NEXIS with Cisco Nexus 9336C-FX2

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 65 of 242

2.4 JUNIPER - Custom/Deployed designs This section provides detail of successful deployments that have been implemented with some element of funded testing attached, using Juniper products.

2.4.1 QFX 10008 and QFX5100 This testing was conducted in SEPTEMBER 2017. The QFX 10008 as core switch with QFX-5100-24Q as server edge and QFX5100-48 T as the client edge switch. Note the QFX5100 is a Trident 2 based device and was only tested as a Layer 2 switch.

Figure 10 – Custom design for NEXIS E5 with Juniper

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 66 of 242

2.4.2 Juniper Buffer limitation with Trident 2 Merchant Silicon This family underwent customer testing in SEP 2017, as a layer 2 switch, All Layer 3 functions were performed by an upstream QFX10000 switch. However, it is expected that this would perform in a similar manner as other approved Trident 2 based switches.

The Juniper QFX 5100-48T (also applies to the QFX-5100-48S) as a layer 2 switch is suitable for use with Avid NEXIS edge clients. By default it will drop packets, but the NEXIS clients survive this. The buffers can be configured so as not to drop packets, and this is recommended as the preferred configuration style. This switch was not tested as a layer 3 device with NEXIS storage directly connected, but it is expected that this would perform in a similar manner as other approved Trident 2 based switches. The Juniper QFX 5100-48T (also applies to the QFX-5100-48S) as a layer 2 switch is suitable for use with Avid ISIS 7500 edge clients only when the enhanced buffer configuration (described elsewhere in this document) are used to prevent packet dropping. This device was not tested as a layer 3 device with ISIS 7500 storage directly connected, but it is expected that this would perform in a similar manner as other approved Trident 2 based switches.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 67 of 242

The Juniper QFX 5100-24Q (as a stacked switch) was used to connect the NEXIS engines at 40G, as a layer 2 switch, and is considered suitable for this task. The edge buffering was not changed from default as the path toward 40G Engines would normally be oversubscribed, but the deployed of the enhanced buffer command should not have a detrimental effect. This switch was not tested as a layer 3 device with NEXIS storage directly connected, but it is expected that this would perform in a similar manner as other approved Trident 2 based switches. The Juniper QFX 5100-24Q (as a stacked switch) was used to connect the ISIS 7500 engines at 10G, via 40G-10G breakout, as a layer 2 switch, and is considered suitable for this task. The edge buffering was not changed from default as the path toward 40G Engines would normally be oversubscribed, but the deployed of the enhanced buffer command should not have a detrimental effect. This device was not tested as a layer 3 device with ISIS 7500 storage directly connected, but it is expected that this would perform in a similar manner as other approved Trident 2 based switches. 2.4.2.1 Juniper QFX-5100 Configuration statements used for setting the egress shared buffer: Setting the percentage of available (non-reserved) buffers used for the egress global shared buffer pool - #set class-of-service shared-buffer egress percent 100

Configuring the shared buffer for the egress based on the recommended values for unicast traffic– #set class-of-service shared-buffer egress buffer-partition lossless percent 5

#set class-of-service shared-buffer egress buffer-partition lossy percent 75 #set class-of-service shared-buffer egress buffer-partition multicast percent 20

root@str-er1-ss12> show configuration class-of-service shared-buffer { egress { percent 100; buffer-partition lossless { percent 5; } buffer-partition lossy { percent 75; } buffer-partition multicast { percent 20; } } } Commands to deactivate the shared buffer configuration: #deactivate class-of-service shared-buffer egress percent 100 #deactivate class-of-service shared-buffer egress buffer-partition lossless percent 5 #deactivate class-of-service shared-buffer egress buffer-partition lossy percent 75 #deactivate class-of-service shared-buffer egress buffer-partition multicast percent 20

Commands to activate the shared buffer configuration: #activate class-of-service shared-buffer egress percent 100 #activate class-of-service shared-buffer egress buffer-partition lossless percent 5

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 68 of 242

#activate class-of-service shared-buffer egress buffer-partition lossy percent 75 #activate class-of-service shared-buffer egress buffer-partition multicast percent 20

2.4.3 QFX 10008 and QFX5110 APRIL 2018

SERVER EDGE LAYER 2 CORE LAYER 3 CLIENT EDGE LAYER 2

QFX5110 -48S-FSI

(Trident 2+)

QFX10008

QFX10000-30C 10/40GE deep buffer line card

QFX5110 -48S-FSI

(Trident 2+)

The solution performed as expected in terms of supporting the video load with no errors.

Correct operation was observed with ISIS 7500 storage and clients for video and PATHDIAG

Correct operation was observed with ISIS 5500 storage and clients for video and PATHDIAG

Correct operation was observed with NEXIS storage and clients for video and PATHDIAG

This testing was done with a small number of clients and storage engines so does not represent full load testing, but does reflect operational capability. It was possible to create packet drop with default settings for buffering with BOTH ISIS 7500 and NEXIS. It was possible to prevent packet drop with enhanced settings for buffering, with the limitation of the testing resources. An enhanced buffer setting, as described in section 2.4.2, should be used for a deployment, with a percentage split between LOSSY/LOSSLESS suitable for all applications used in the desired deployment.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 69 of 242

2.4.4 QFX 5120 & EX4400 NETWORK DESIGN Based on testing done in SEP 2021. The QFX 5120 was testing as VRRP/MLAG and Virtual chassis and subordinate L2 switch

The QFX 5120 should use the same buffer configuration should be optimised as listed in section 2.4 for QFX 5100. The EX4400 was test as a Layer 3 switch with LACP connection to NEXIS. As only a single device was available no VVRP/MLAG or Virtual chassis testing could be conducted. The buffer commands below should be applied to reduce packet discard on the egress buffers:

set class-of-service shared-buffer 85

See section 7.3 for more information about the custom testing

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 70 of 242

2.5 ARISTA - Custom/Deployed designs This section provides detail of successful deployments that have been implemented with some element of funded testing attached, using ARISTA products.

2.5.1 ARISTA 7500R and 7280R TESTING MARCH 2018

SERVER EDGE LAYER 2 CORE LAYER 3 CLIENT EDGE LAYER 2

7280R

Leaves = 2xDCS-7280SR2A-48YC6, version 4.19.3F

7500R

Spines = 2x DCS-7504N, version 4.19.3F

Line cards = 2x7500R-36CQ-LC per spine

7280R

Leaves = 2xDCS-7280SR2A-48YC6, version 4.19.3F

The solution performed as expected in terms of supporting the video load with no errors.

Correct operation was observed with ISIS 7500 storage and clients for video and PATHDIAG

Correct operation was observed with ISIS 5500 storage and clients for video and PATHDIAG

Correct operation was observed with NEXIS storage and clients for video and PATHDIAG

This testing was done with a small number of clients and storage engines so does not represent full load testing but does reflect operational capability.

2.5.2 ARISTA - PROVEN DEPLOYMENTS WITH NEXIS

2.5.2.1 SPINE/LEAF

LOCATION YEAR SPINE LEAF

USA 2019 7500R (Jericho) 7280QR-C36 (Jericho) LEAF for STORAGE and VM

7280SR-48C6 (QumranMX) a LEAF for BARE METAL SERVERS AND NLE

AFRICA 2019 7280CR2A-30 (Jericho+)

7280SR-48C6 (QumranMX) LEAF for VM & BARE METAL SERVER

7280TR-48C6 (QumranMX) LEAF for NLE

APAC 2020 7500R2 (Jericho+) 7280QR-C36 (Jericho) LEAF for STORAGE and VM

7280SR-48C6 (QumranMX) LEAF for BARE METAL SERVERS

7280TR-48C6 (QumranMX) LEAF for NLE

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 71 of 242

2.5.2.2 MULTITIER

LOCATION YEAR CORE EDGE

EUROPE 2020 DCS-7280QR-C36-F (Jericho)

EXISTING NETWORK

EUROPE 2020 Arista 7050CX3 (Trident3)

EXISTING NETWORK

LATAM 2021 DCS-7280QR-C36-F (Jericho)

DCS-7280SR-48C6-F (QumranMX) SERVERS

DCS-7020TR-48-F (QumranAX) NLE

ALL DEVICES USING Software image version: 4.23.5M

2.6 SPINE/LEAF - Custom/Deployed designs This section provides detail of successful deployments that have been implemented, these are not vendor specific

Note: The spine product should be of little relevance, there are frequent releases of higher specification merchant and custom silicon, it is the Leaf (or edge) products that connect with NEXIS client, and to a lesser extent the storage engines, where the buffering capability is important.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 72 of 242

3.0 VIRTUAL MACHINES AND BLADE SERVERS Beginning with Interplay V3.3 In July 2015, Avid begin to support Virtual Machine based solutions on Dell R630 servers and HP DL360Gen8 hardware platforms. Avid publishes a document Interplay Virtualization Best Practices, which is updated in line with different Interplay versions as appropriate (see interplay documentation). The purpose of this section is to provide some additional information on differing hardware platforms that have undergone informal testing or have been deployed in larger customers. One principle of virtual machines is to allow deployment on homogenous hardware platforms, with the necessary resources such CPU, RAM, NIC, HDD etc. However, this can “conflict” with some vendor specific supported solutions, but those vendors, such as Avid, now have to adjust. Sometimes the full-on performance of a tightly specified bare metal hardware platform cannot be matched by a blade server. In this situation, providing the solution still works sufficiently, the benefits of a lower overall performance may be outweighed by the benefits of a homogenous solution. Some virtual machine hardware platforms also can support high performance video adapters that used to be the domain of workstations, this allows centralize deployment alongside suitable advance KVM platforms.

3.1 Cisco UCS Cisco offers two UCS platforms, the C class is a bare metal format, while the B class is a blade format. With the Blade format, it is also necessary to deploy the Virtual Interface Card (VIC) and the Fabric Interconnect and the FEX/IOM (Fabric Extender /Input Output Module Input), and this is effectively collapsing much of the Access Layer into a single box, greatly reducing the number of external cables to the outside world, by using converged backplane 10GBASE-KR and/or 40GBASE-KR connections. The C class bare metal format, can use the VIC along with and external FEX or use traditional NIC solutions. The UCS products enable a converged environment where Ethernet, Fiberchannel and ILO are combined into a single adapter called a VIC, which can provide up to 256 virtual adapters The Fabric Interconnect solutions are evolutions of Nexus 1U switches, running different s/w to add new features. Some architectures that were not well suited to deployment ISIS 7500 storage servers and 1G edge clients do not encounter the same challenges when deployed with 10G VMs and/or NEXIS storage servers. The integrated FEX/IOM (Fabric Extender /Input Output Module Input) are evolutions of the 1U Nexus 2000 solutions.

3.1.1 UCS with FI 6248 As part of a USA based customer proof of concept system in 2016, on a Cisco UCS loaner platform, some comparison tests were done between a four-engine ISIS5x00 stack and the following:

AS3000/Myricom

R630/QLOGIC 57840

R730/QLOGIC 57810

Cisco 5108 chassis/VIC1340/2208FEX/6248 Fabric Interconnect

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 73 of 242

There was also some limited ISIS7x00 tests alongside the ISIS5x00 tests. The short answer is that the cisco configuration performed as well as the other configurations for a single VM on the UCS. When additional VMs were added to see if the result would scale, 2 VMs worked OK, but the write latencies increased when a 3rd VM was added. That said, the test bed was also hosting VMs for other Interplay development work, so those could have impacted the linearity of these scalability tests. The customer deployment with ISIS 7500 is in production without issue. The FI 6248 platform is based on an enhanced version the Nexus 5548 platform. The FEX 2208 is based on a re-packaged version the Nexus 2248 platform. This platform combination has not been exhaustively tested by Avid or received any official sanction. However empirical evidence suggests that it is broadly suitable/field proven when configured appropriately. 3.1.1.1 Media Central VM best practices A Cisco UCS hardware platform has been tested with Media Central in a VM environment as described in the extract below from the MediaCentral document: MediaCentral Platform Services Virtual Environment with VMware® Best Practices Guide The URL will vary with version, which is currently V2.9 at time of writing this section (MAR 2017). http://avid.force.com/pkb/articles/en_US/readme/Avid-MediaCentral-Version-2-9-x-Documentation

Avid used a Cisco UCS Blade Server as a validation system for the host server and the vSphere cluster. Avid followed the VMware best practices for setting up the validation environment.

ESXi 6 installed on hard drives provided on the UCS blades

Assigned Enterprise Plus license on all three blades. The following table lists the technical details of the Cisco UCS 5108 Blade Server used for VMware validation:

Processor Intel Xeon E5-2697 v3

Form factor Cisco UCS blade (B200 M4)

Number of Processors 2

Processor Base Frequency 2.6 GHz

RAM 128 GB DDR4 RDIMM - ECC Networking Cisco UCS VIC 1340 with UCS 2208XP Fabric Extenders and dual UCS 6248UP Fabric Interconnects (FI) Connections:

Eight connections between the Cisco 5108 and the FI’s.

Four 10GbE connections between the FI’s (as a port channel group) and the iSCSI VLAN of the parent switch (Dell S4810).

MediaCentral Server is a demanding application on CPU and memory.

3.1.2 UCS with FI 6332 The Cisco UCS B200-M4 with IOM 2304 and FI 6332 has been deployed by major USA broadcaster for almost a year (written MAR 2017) it has been working fine. This configuration has the FI 6332’s uplinked to a Nexus7710 via 4 x 40GB trunk and ISIS 7x00 also connected to the same N7710 core.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 74 of 242

Another major USA broadcaster also have a PoC system that we installed a few months ago (written MAR 2017) running Interplay PAM and MAM on UCS B200-M4. The FI 6332 platform is based on a version of the Nexus 9300 Trident 2 based switches platform (but without the ALE). The FEX 2304 is based on a re-packaged version the Nexus 2348 platform. This platform combination has not been exhaustively tested by Avid or received any official sanction. However empirical evidence suggests that it is broadly suitable/field proven when configured appropriately. The Picture below shows and example deployed design.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 75 of 242

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 76 of 242

4.0 WIDE AREA AND DATA CENTER NETWORKING This section discusses some of the newer techniques used I modern data centres and how they might (or might not) affect NEXIS operation. This document is not intended to educate the reader in these areas. There are many tutorials, blogs and whitepapers which will are better placed to achieve such an objective.

4.1 MPLS Multi Protocol Label Switching is essentially as a high-speed WAN technology provide by Internet Service providers, which has been adopted by many companies that present IT services internally on Service Provider model. From a simplistic point of view MPLS is an encapsulation technology which add 4 bytes to the packet for each encapsulation stage, generally there are 2 or 3 stages so a maximum of 12 bytes is added. This does not decrease the original packet MTU as the network path must be able to cope with this. At the final stage of de-encapsulation, the original packet is sent to the terminating device. The new outer bytes allow a predetermined path to be taken with fast routing or switching of the packet based on its label, rather than traditional hop-by-hop routing which is slower and more CPU intensive. For many years (since 2007) several Broadcasters have used MPLS on their campus deployments, and WAN circuits between regions to Transport ISIS 7x00 and 5x00 traffic and latterly NEXIS traffic. This document is not intended to educate the reader in this area. There are many tutorials, blogs and whitepapers which will are better placed to achieve such an objective.

4.2 Wavelength-division multiplexing The principle of WDM is simple, use differing wavelengths along the same cable to get more transmission capacity, and there no problem using it for NEXIS or ISIS clients, if it is implemented properly. After all a one wavelength is a good as another when it comes to capacity. This is a layer one function that has no impact on buffering or throughput. So, to the principle; instead of sending white light between devices, send red green and blue separately and triple the capacity, in fact it is all variation of red (dark almost invisible to humans red), CWDM is generally 4-16 colours and DWDM is generally 32-96 colours and a lot more expensive. The normal MMF (850nm) or SMF (1310nm) transceivers are referred to as “grey” transceivers (but they are actually red too, as visible Red is 620–750 nm), and extra-long-range device uses 1550nm. https://en.wikipedia.org/wiki/Visible_spectrum https://en.wikipedia.org/wiki/Small_form-factor_pluggable_transceiver https://en.wikipedia.org/wiki/Wavelength-division_multiplexing WDM devices can be electrical multiplexers or optical multiplexers. An electrical multiplexer takes a “grey” signal ++( could be 850mn or 1310 nm - for 10Gor RJ45 Ethernet) and converted to an electrical signal then to a specific colour which is then transmitted onto the fibre and de-multiplexed at the receiver to. An optical multiplexer requires that the light is already using one of the “special colours” before it enters the multiplexer, hence it is normal to use a transceiver that uses the particular wavelength from the outset. Usually, this transceiver is fitted into the network switch or

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 77 of 242

router, some transceivers are programmable for different wavelengths. Sometime a transceiver will be use in a NIC. For use with Avid storage solution the best method is to use an electrical multiplexer, or if an optical multiplexer is deployed, then a transceiver in the Switch is the better solution and not a transceiver in a NIC, because a transceiver in a NIC serves one device only and also the Avid supported NICs may not work with “coloured” transceivers.

4.3 Software Defined Networking –SDN Essentially SDN is a method of Automation and programmatic control. The control plane is managed by and external device which tells the local device data plane what to do. As ever it is the capability of the network edge devices that matter the most for Avid storage traffic (storage servers and storage clients). If the hardware is capable, and correctly configured by upstream devices, then the NEXIS (or ISIS) traffic passing through the data plane should not be impacted by the control plane separation. This document is not intended to educate the reader in this area. There are many tutorials, blogs and whitepapers which will are better placed to achieve such an objective.

4.4 VXLAN VXLAN is an L2 overlay over an L3 network, Virtual Extensible LAN (VXLAN) uses network virtualization overlay to mitigate the scalability problems in large data centers, which often feature Spine & Leaf designs and quickly reach limitations of convention VLANS. It is essentially and encapsulation, like MPLS, and borrow many techniques from MPLS (such as Q-in-Q) but applies them differently. Each overlay network is known as a VXLAN Segment and identified by a unique 24-bit segment ID called a VXLAN Network Identifier (VNI). Only virtual machines on the same VNI are allowed to communicate with each other. But virtual machines will/may be mobile around the network estate. VXLAN encapsulation may begin within the VM, at the virtual switch, or for real tin devices it will begin at the physical switch. Essentially, just like MPLS, the encapsulation is removed before it gets to the end device so packet should be exactly the same as when they began their journey. Some good tutorials are: VxLAN | Part 1 - How VxLAN Works (part 1 of 6) https://www.youtube.com/watch?v=YNqKDI_bnPM&list=PLDQaRcbiSnqFe6pyaSy-Hwj8XRFPgZ5h8 https://www.youtube.com/watch?v=YNqKDI_bnPM

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 78 of 242

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 79 of 242

4.4.1 VXLAN Overheads A large network vendor assisted with most of this sub-section: Best practice for VXLAN fabrics is adjusting MTU on the network equipment to accommodate 50bytes overhead. Here is a snippet from a config guide:

• MTU Size in the Transport Network Due to the MAC-to-UDP encapsulation, VXLAN introduces 50-byte overhead to the original frames. Therefore, the maximum transmission unit (MTU) in the transport network needs to be increased by 50 bytes. If the overlays use a 1500-byte MTU, the transport network needs to be configured to accommodate 1550-byte packets at a minimum. Jumbo-frame support in the transport network is required if the overlay applications tend to use larger frame sizes than 1500 bytes.

With the advent of widespread use Merchant Silicon, in since 2012, I would guess that all the major vendors offer enterprise class and above equipment is jumbo capable, so there should be no need for MTU squeeze and hence likely fragmentation of packets. And I expect that applies equally to vendor custom silicon and hence cloud providers.

4.4.2 VXLAN questions The extracts below are from an and email exchange in FEB 2018. 1.VXLAN introduces 50-byte overhead to the original frames. Can this cause a problem with AVID? [DS] I am not aware that NEXIS has been explicitly tested in a VXLAN scenario, however this would not be submitting a VXLAN frame directly to NEXIS, the VXLAN header would be stripped beforehand at the edge switch just like MPLS. We have sites successfully using ISIS 7500 with MPLS for many years. If the ability of the network infrastructure to carry the VXLAN overhead in a mini-jumbo frame exists, and the NEXIS frame is not reduced the existence of VXLAN should be transparent as with MPLS. 2.Is there restrictions or limitations with MTU using Jumbo Frames? [DS] The NEXIS solution has not been tested in a jumbo frame environment, and a max MTU of 1500 is what we expect. However, some of the restriction of the ISIS infrastructure which absolutely made jumbo frames impossible are not part of NEXIS. Nexis still use small UDP fragments, and this part has not been tested. For TCP, there would be a negotiation of MSS between the endpoints which would restrict the MTU anyway. 3. What MTU AVID is using and is it under 9000 bytes? [DS] The NEXIS solution has not been tested in a jumbo frame environment, and a max MTU of 1500 is what we expect. 4.Do you have other clients using SDN data centre and do they have any issues with AVID? [DS] The NEXIS solution has not been tested in a SDN environment. However, our products are being developed for use in the Azure cloud, which means we lose control of the network environment, and VXLAN encapsulation is a “given” based on the automated/portable deployment nature of the

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 80 of 242

virtual machines that are used. SDN is just a control protocol, what is important for successful operation of Avid applications is low latency and edge buffering. Nexis clients can survive in with less edge buffering and even a low percentage of packet discard will not cause frame drop, because we use TCP with FRR instead of Fragmented UDP as with ISIS 7x00.

4.4.4 VXLAN and Multicast See section below in Appendix B - B.20.4 Some other useful Multicast URL & Information

4.5 Spine/Leaf Networks Spine and Leaf networks are a common deployments model for data centre networks and there are a multitude of resources on the Internet, that negate the need to explain here in great detail. Unfortunately, what some folks refer to as Spine/Leaf deployment could almost be applied to simple (classical/legacy) C4500X deployments with multiple C4948E edge switches, but true Spine/Leaf brings a host on new challenges and protocols to address. Spine/Leaf is likely to have BGP-EVPS and VXLAN encapsulation and off device portability of virtual machines. How the underlay network deals with the overheads of the overlay network needs to be better understood. Possibly even throw in SDN as part of the recipe too. However, if the underlying MTU of 1500 bytes common in the “traditional” network environment is maintained/preserved and the switches have sufficient edge buffering to address the needs of the speed transition experiences along the path and from source to destination, then such a transport path should be transparent to the Avid applications. I have customer that have been using MPLS with ISIS 7x00 for 10 years without issue. For me Spine/Leaf means 2-6 spine switches and tens or hundreds of leaves and a data centre environment with homogenous server hardware. Is the user-edge e.g. for the NLE, within a campus element of a network deployment another leaf, or is it a separate network with the appropriate segregation, perhaps via firewall? Avid would need to know a lot more about any intend deployment to give a anything more than a general answer.

4.6 Adapter Teaming The teaming of adapters is a very nebulous subject. The support for this technique, commonly used in data centres, across Avid application is not consistent. Also, adapter teaming capabilities and characteristics differ across operating systems and/or NIC vendors. This subsection provides pointers to useful resources rather than extolling and explicit support. Historically many systems in the file have deployed INTEL NIC teaming with Clients on Windows 7 and Servers on Windows 2008, but with Windows 10 and Server 2012/2016 the methodologies have changed. Add to this the “relevance” of NIC teaming change considerably when using Virtual Machines, Blade Servers and Fabric based solutions such as Cisco UCS. There is no “one size fits all” solution, the best solution for any one situation depends on many different criteria, and should be tested prior to deployment for normal operation and disrupted operation.

Section 5.8 of NETREQS V1.2x contains legacy information on Adapter Teaming which may be helpful to the reader.

Note: There are many different types of teaming (see section 4.6 for a little more information), just like there are many different teams in sport: a baseball teams, a hockey team, a cricket team. Then sometimes the same teaming method has

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 81 of 242

different name e.g. USA:Soccer = Europe:Football ( stick with it, this is going somewhere!) The same happens in operating systems and between vendors too. For example, in Windows 7 with Intel NIC we had Switch fault tolerant teaming, but in Windows Server 2012 this was named Load Balance Fail Over, and in Linux this was called Active-Backup Bonding (a latterly teaming), all the same thing with different names, do be prepared for a confusing journey for resilient connectivity.

4.6.1 Teaming with Intel NICs Teaming with Intel® Advanced Network Services Last Reviewed: 13-Dec-2017 Article ID: 000005667 https://www.intel.co.uk/content/www/uk/en/support/articles/000005667/network-and-i-o/ethernet-products.html Adapter teaming with Intel® Advanced Network Services (Intel® ANS) uses an intermediate driver to group multiple physical ports. You can use teaming to add fault tolerance, load balancing, and link aggregation features to a group of ports. The seven teaming modes:

1. Adapter Fault Tolerance (AFT) 2. Switch Fault Tolerance (SFT) 3. Adaptive Load Balancing (ALB) 4. Receive Load Balancing (RLB) 5. Virtual Machine Load Balancing (VMLB) 6. Link Aggregation (LA), Cisco* Fast EtherChannel (FEC), and Gigabit EtherChannel (GEC) 7. IEEE 802.3ad Link Aggregation

4.6.1.1 INTEL NIC Teaming in Windows 10 Teaming was not available in early version of Windows 10. There are many articles on the internet about this, and some of them refer to the use of LBFO functionality from Windows 2012. It appears that Microsoft, in its infinite wisdom, considers the teaming is unnecessary on client devices. The Intel article below has some pointers that will explain more about the possibilities available. https://www.intel.co.uk/content/www/uk/en/support/articles/000021723/network-and-i-o.html Enable NIC Teaming in Windows® 10 Using PowerShell* Last Reviewed: 08-Nov-2017 Article ID: 000021723

Teaming for Avid application is still possible by using multiple NICs and the “integrated AALB” functionality, and this can be very useful when additional bandwidth is necessary, but the “next NIC size” is not viable.

4.6.2 NIC Teaming Windows 2012 NIC Teaming, also known as load balancing and failover (LBFO), allows multiple network adapters on a computer to be placed into a team for the following purposes:

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 82 of 242

Bandwidth aggregation

Traffic failover to prevent connectivity loss in the event of a network component failure This feature has been a requirement for independent hardware vendors (IHVs) to enter the server network adapter market, but until now NIC Teaming has not been included in Windows Server operating systems. NIC Teaming Overview 08/31/2016 Updated: June 7, 2016 https://docs.microsoft.com/en-us/previous-versions/windows/it-pro/windows-server-2012-R2-and-2012/hh831648(v=ws.11) For more information about NIC Teaming in Windows Server® 2012, see Windows Server 2012 NIC Teaming User Guide. https://gallery.technet.microsoft.com/windows-server-2012-nic-bae6d72e For more information about NIC Teaming in Windows Server® 2012 R2, see Windows Server 2012 R2 NIC Teaming User Guide. https://gallery.technet.microsoft.com/windows-server-2012-r2-nic-85aa1318

Note: Intel web pages on teaming recommends using Microsoft teaming on Server 2012/2016

4.6.3 NIC Teaming Windows 2016 NIC Teaming allows you to group between one and thirty-two physical Ethernet network adapters into one or more software-based virtual network adapters. These virtual network adapters provide fast performance and fault tolerance in the event of a network adapter failure. NIC Team member network adapters must all be installed in the same physical host computer to be placed in a team.

4.6.4 Windows Server TEAMING – MORE ARTICLES Some other more recent articles of interest for all versions of Windows Server: NIC Teaming settings https://docs.microsoft.com/en-us/windows-server/networking/technologies/nic-teaming/nic-teaming-settings Understanding NIC Teaming in Windows Server https://adamtheautomator.com/nic-teaming/

4.6.5 Linux Bonding and Teaming Linux network Bonding is a creation of a single bonded interface by combining 2 or more Ethernet interfaces. This helps in high availability of your network interface and offers performance improvements on your data traffic flow. Bonding is also referred as NIC trunking or teaming.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 83 of 242

Linux Network bonding – setup guide Posted on July 17, 2015Posted in Linux https://www.cloudibee.com/network-bonding-modes/ Bonding allows you to aggregate multiple ports into a single group, effectively combining the bandwidth into a single connection. Network Bonding also allows you to create multi-gigabit pipes to transport traffic through the highest traffic areas of your network. For example, you can aggregate three 1GBps ports into a 3GBps trunk port. That is equivalent with having one interface with 3GBps speed. There are 7 modes of Bonding, and these are explained in more detail in the reference article. The modes are

mode=0 (Balance Round Robin) mode=1 (Active backup) mode=2 (Balance XOR) mode=3 (Broadcast) mode=4 (802.3ad) mode=5 (Balance TLB) mode=6 (Balance ALB)

DESCRIPTIONS OF BALANCING ALGORITHM MODES The balancing algorithm is set with the xmit_hash_policy option. Possible values are: layer2 Uses XOR of hardware MAC addresses to generate the hash. This algorithm will place all traffic to a particular network peer on the same slave. layer2+3 Uses XOR of hardware MAC addresses and IP addresses to generate the hash. This algorithm will place all traffic to a particular network peer on the same slave. layer3+4 This policy uses upper layer protocol information, when available, to generate the hash. This allows for traffic to a particular network peer to span multiple slaves, although a single connection will not span multiple slaves. encap2+3 This policy uses the same formula as layer2+3 but it relies on skb_flow_dissect to obtain the header fields which might result in the use of inner headers if an encapsulation protocol is used. encap3+4 This policy uses the same formula as layer3+4 but it relies on skb_flow_dissect to obtain the header fields which might result in the use of inner headers if an encapsulation protocol is used. The default value is layer2. This option was added in bonding version 2.6.3. In earlier versions of bonding, this parameter does not exist, and the layer2 policy is the only policy. The layer2+3 value was added for bonding version 3.2.2. Source: https://help.ubuntu.com/community/UbuntuBonding#Descriptions_of_balancing_algorithm_modes

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 84 of 242

Also see: https://access.redhat.com/documentation/en-us/red_hat_enterprise_linux/7/html/networking_guide/sec-using_channel_bonding 4.6.5.1 LINUX TEAMING NEXIS uses TEAMING in preference to BONDING for resilient outbound connections, as TEAMING is a newer and better than BONDING. The articles below provide some background.

https://tobyheywood.com/network-bonding-vs-teaming-in-linux/

https://access.redhat.com/documentation/en-us/red_hat_enterprise_linux/7/html/networking_guide/sec-comparison_of_network_teaming_to_bonding https://access.redhat.com/documentation/en-us/red_hat_enterprise_linux/7/html/networking_guide/sec-understanding_the_network_teaming_daemon_and_the_runners https://access.redhat.com/documentation/en-us/red_hat_enterprise_linux/7/html/networking_guide/sec-controlling_teamd_with_teamdctl Linux has slightly separate definition for Bonding and Teaming. Bonding refers to create a bond or aggregation of two or more links into one in order to provide failover and redundancy to the network. Teaming is a new way implementation of bonding and provides a separate driver. Teaming provides more features and a way towards automation as network manager can handle the interfaces with modular design and hence considered a modern way of handing the interfaces. See: https://ngelinux.com/difference-between-bonding-and-teaming-in-linux/ Think of Bonding as the manual gearbox (or stick-shift) and TEAMING as the automatic gearbox, both still drive along the road.

4.6.6 TEAMING WITH FASTSERVE INGEST FastServe Ingest is a Linux device. Page 44 of the 2019 FastServe Ingest Administrator guide mentions TEAMING http://resources.avid.com/SupportFiles/attach/FastServe/FastServe_Ingest_AG_v2019.6.pdf

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 85 of 242

The teaming mode is “bonding with active-backup redundancy” which can be best compared with AFT and SFT modes listed for Windows. Specifically use these parameters when bonding adapter is created: BONDING_OPTS="resend_igmp=1 use_carrier=0 miimon=100 fail_over_mac=1 primary_reselect=2 downdelay=0 mode=1" for more information https://www.kernel.org/doc/Documentation/networking/bonding.txt

4.7 Cisco Transceiver Enterprise-Class versions Cisco and possible other vendors have different capability optics. Some cheaper version are now listed as Enterprise class. What this really means in ETHERNET only. There are version for many different Ethernet speeds. For example, a LR 10G SPF comes as

SFP-10G-LR-S= 10GBASE-LR SFP Module, Enterprise-Class $2,000

SFP-10G-LR= 10GBASE-LR SFP Module $3,995 (US $ list priced shown) SFP-10G-LR-S=10GBASE-LR SFP Module, Enterprise-Class = S class See article at https://community.cisco.com/t5/optical-networking/sfp-10g-lr-s-vs-sfp-10g-lr/td-p/2630525

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 86 of 242

The use of iSCSI is not impacted because it is contained within Ethernet frames. This make Cisco parts more price competitive because often the lower cost third party products are Ethernet only and not “Carrier class” and able to support different layer 2 protocols.

4.8 Jumbo Frames and Avid applications Jumbo frames are a very misunderstood technology, and there are many caveats and many twists and turns, and this is not just for Avid. Avid applications do not use (or need) jumbo frames. Avid does not test its applications in a Jumbo frame enable environment, as at SEP 2019. Non jumbo frame TCP application can work successfully over a Jumbo frame enabled environment, because the MSS (and hence MTU) is negotiated before transmission. Hence if the local MTU of the device is set within the OS to 1500 (as normal) all should be fine. HOWEVER, UDP applications, especially those that use fragments such as ISIS/NEXIS, can have issue in a jumbo frame, especially when “helpful” intermediate devices might adjust the size of fragments (or fully reassemble) based on larger MTU sizes. A prime example of this is EVS where separate adapter must be used with different MTU settings, although using jumbo frames fixes a problem which no longer exists at 1/10G but will become apparent again as we move to 100G+ applications. VXLAN overlay networks are a prime example of a Jumbo Frame technology which is used to carry no-jumbo frame messages (to ensure VM portability), and this is common in a spine/leaf architecture, but with VXLAN the VTPE (VXLAN tunnel Endpoint) is responsible for local connection at appropriate MTU (which may differ by application). There is no reason for a MediaComposer or any Avid MediaCentral (or Interplay) to be configured to use jumbo frames. Any VM deployment (as a VM hypervisor can be a VTEP) should be configured to ensure that no jumbo frames are sent to any Avid application.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 87 of 242

Regarding NEXIS and jumbo frames, in theory it is capable of accepting Jumbo frames because the NIC is capable but not configured to do so as shown below.

gx0

Link encap:Ethernet HWaddr e4:1d:2d:4f:4f:80 inet addr:10.42.25.146 Bcast:10.42.25.255 Mask:255.255.255.128 inet6 addr: fe80::e61d:2dff:fe4f:4f80/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:91132536 errors:0 dropped:0 overruns:0 frame:0 TX packets:89538034 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:28596021094 (26.6 GiB) TX bytes:79158572019 (73.7 GiB)

Hence the NIC should reject a jumbo frame if one is received. Also see section 4.4 VXLAN to understand how jumbo frames are used in an overlay network.

4.9 NO specific VPN requirements for use with Thin Client applications While Avid has not done any testing of vendor specific VPN solutions, it probably does not need to. The requirement to do testing on network switches has always been about the need for edge buffering because of speed changes between storage server and FAT clients, this should not be an issue for VPN, as the speed change has probably already occurs at the edge switch in front of the VPN server (unless it is 10G connected), or it happens somewhere in the path from VPN server egress toward the receiving client where no control is possible. Also, when using solutions based around the MediaCentral THIN client applications, the hard work has already been done by the MCS Server and it delivers a low bandwidth TCP stream toward the receiving client. There are many different types of VPN, and many different names that get associated with them, but all do the same basic thing, tunnel, encrypt, authenticate and restrict (firewall). So, you have IPSEC VPN, SSL VPN, L2TP VPN, INTRANET VPN, EXTRANET VPN, Dynamic Multipoint VPN, SITE-TO-SITE VPN, GRE VPN, MPLS VPN. Many of these features overlap or are a mixture of the others. So, the key points of any VPN solution are Does it have the link capacity for intended workload? Does it have the client quantity capacity for intended workload? Does it have the desired encryption capability for intended workload? Does it have the desired authentication capability for intended workload? Does it have the desired integrity verification capability for intended workload? Does it have the required firewalling capability for intended workload? The URL below from which this next image is taken provide a good explanation of the various concepts that can be applied in Virtual Private Networks https://en.wikipedia.org/wiki/Virtual_private_network

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 88 of 242

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 89 of 242

5.0 MEDIA CENTRAL This section will be used for the newly branded Media central Family release in 2018

5.1 Media Central UX Bandwidth requirements Data extracted from http://resources.avid.com/SupportFiles/attach/MediaCentral_Cloud_UX/MCCUX_2017_2_0_ReadMe.pdf The following table presents single-user bandwidth guidelines for MediaCentral Cloud UX playback. The table is provided for guidance, and is not an indication of performance guarantees.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 90 of 242

The following table explains the contents in detail. Item Description

Width aspect ratio. The table assumes an aspect ratio of 16:9.

Quality Refers to the quality setting in the Player set via the UI. Compatibility Notes and Issues

14

Value Each quality setting has a numeric value. In JPEG compression literature, these are often thought of as percentages of original image (e.g. 100% is equivalent to uncompressed; 1% represents a severely degraded image).

Peak Video with high color variation (e.g. wide shot of a crowd)

Valley Video with low color variation (e.g. half of frame consists of a clear blue sky)

Typical A wide range of footage (e.g. interiors, exteriors, interviews). The typical shot tends closer to valley values than peak values.

Audio All bandwidth figures include audio consisting of 44.1 kHz sample rate x 16-bit/sample x 2 tracks = 1.4 Mbps

5.2 Media Central Cloud UX Server Connectivity requirements It is documented that for Media Central Cloud UX Server, the NEXIS client must bind to a single adapter. This has precluded the use of teamed adapters to provide network resilience. See custom testing section 7.1 for results of successful testing with teamed network adapters.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 91 of 242

7.0 CUSTOM TESTING This section will focus on custom testing that has been conducted on customer site and that is not mentioned elsewhere in this document. See section B.36 for implementation notes.

7.1 TESTING BONDED ADAPTER WITH MEDIA CENTRAL CLOUD UX SERVER This so-site testing was conducted in NOV 2018 for an APAC customer. This section contains the Executive Summary and some of Conclusions appropriate for this section. This was done with Media Central Cloud UX Server V2018.9 and the deployment will be upgrade to 2018.11 before deployment. It is high likely that it is full backward compatible with earlier version as far back as Media Central Server 2.x. The NIC use for this testing was Broadcom 57412 2 x 10Gb SFP+ (see section 7.2 for more details)

Note: This customer testing was done with BONDING. In Linux BONDING and TEAMING are a little different, but both allow resilient LACP connection to be created to and upstream switch (or MLAG switches). Bonding is the old way, and must be done manually at the CLI or using NMTUI or NMCLI. TEAMING is the newer way and can be created using NMTUI or NMCLI, but also it can be controlled/initiated/changes but upstream application and use automation techniques, hence it is much more flexible. A TEAMED connection can add/remove members or change parameters “in flight”, this cannot be Done with a BONDED adapter.

Note: There are many different types of teaming (see section 4.6 for a little more information), just like there are many different teams in sport: a baseball teams, a hockey team, a cricket team. Then sometimes the same teaming method has different name e.g. USA:Soccer = Europe:Football ( stick with it, this is going somewhere!) The same happens in operating systems and between vendors too. For example, in Windows 7 with Intel NIC we had Switch fault tolerant teaming, but in Windows Server 2012 this was named Load Balance Fail Over, and in Linux this was called Active-Backup Bonding (a latterly teaming), all the same thing with different names, do be prepared for a confusing journey for resilient connectivity.

7.1.1 Primary Objective The primary objective is to test resilient connections with Media Central Cloud UX Server which has never been explicitly supported (or even tested) by Avid. The testing will attempt using Switch Fault tolerant connection mode=1 (Active backup) and mode=4 (802.3ad) LACP. This will require some config changes on the Switch. A more detailed conclusion can be found in section 9.0 7.1.2. The testing has proven that using two 10G connections as a teamed connection configured with 802.1ad LACP in conjunction with a switch that supports MLAG (Multi-Chassis Link Aggregation) provides significant reliability improvements for connection disruption vs a single connected device. A single “adaptor” is presented to the NEXIS client by the operating system. The enhanced robustness is a major improvement in reliability.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 92 of 242

This adjustment should be considered acceptable custom configuration.

7.1.2 Conclusion Extract The testing has proved that the characteristics of teaming with Linux are very different to Windows & and Intel NIC drivers. Active/Standby failover (Switch Fault Tolerant) connections will failover as expected, but not fail back as expected, hence their suitability for a resilient connection is this workflow is limited. This testing with example workflows has proved that teamed connections offer and increased level of resilience, however, fail-over and fail-back conditions may not be seamless. First testing with REAL data using a simulated workflow on Media Central Cloud UX clients showed that a resilient connection using LACP is quite robust to link disconnection. SFT TEAMING CONCLUSIONS SFT Teaming (and INTEL term) appears unsuited operation with Media Central Cloud UX Server. See section 5 for more detail. LACP TEAMING CONCLUSIONS LACP Teaming is well suited operation with Media Central Cloud UX Server. While not seamless, its operation is Robust and predictable. This method should be used in combination with a switch that supports Multi-Chassis Link Aggregation (MLAG). DISCONNECT TESTS CONCLUSIONS It is far better to have resilient link than single links, it gives choices of how and when to deal with the failure that are not available to single connected machine. The benefits associated with this "unsupported method" greatly exceed the risks. Remedying a failed link or a failed switch is probably best delayed until a suitable maintenance window at the end of the day to minimise disruption.

7.2 Testing Broadcom 57412 Adapter Media Central Cloud UX Server This so-site testing was conducted in NOV 2018 for an APAC customer. This section contains the Executive Summary and some of Conclusions appropriate for this section. This was done with Media Central Cloud UX Server V2018.9 and DELL R640 Servers.

7.2.1 Secondary Objective A secondary objective was to use/test the Broadcom 57400 series adapter (approx. 2017 launch date) which offer 10/25G connectivity. The specification exceeds that of the qualified (but older approx. 2010 launch date) Broadcom 57810 series I/O card, in several aspects. This work was not a formal test of the NIC capabilities, but just a quick test to ascertain basic capability. Insufficient time and resources were available to achieve such a test which would have been a minimum of one full day in itself. This I/O card performed well in the Dell R640 server, but extensive performance testing was not possible due to time and resource limitations.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 93 of 242

This card was used for the workflow tests with adapter teaming as described above in section 7.1.

7.2.2 NIC INFORMATION The DELL RG640 Server comes supplied in default configuration with Dell Quad Port Broadcom 57412 2 x 10Gb SFP+ + 5720, 2 x 1Gb Base-T network connections. This testing used the plug-in option card with SFP+ connection at 10G. New PCI-E Broadcom 57412 Dual port Optical cards were purchased and will be used for testing, there are 3 cards for 3 servers with 6 connections (using teaming). While the Broadcom 57412 interfaces has not been officially tested by Avid, this is not considered a problem.

The Broadcom 57400 series is a newer family 57800 series, that is recommend use in http://resources.avid.com/SupportFiles/attach/Interplay_Virtualization_Best_Practices.pdf but Qlogic 57810 (There is a “relationship” between Qlogic and Broadcom) The Qlogic 57810 uses PCI 2.x and is a 10/40G family (40G as 4 x 10G QUAD port) https://www.broadcom.com/products/ethernet-connectivity/controllers/bcm57416/ https://lenovopress.com/lp0705.pdf This uses PCI 3.x and is a 10/25/40/100G product family. The Broadcom/Qlogic 57810 NIC tested by Avid in a Dell R630 platform as part of Avid Interplay® | Production Virtual Environment with VMware® Best Practices Guide (DEC 2017) This card used PCIe 2.x Specification to communicates with the host platform. This card was launched in 2010 and is 10G operation only. Therefore, a Broadcom 57400 series device should exceed the capability of the older Qlogic 57800 series.

Interplay® | Production Virtual Environment with VMware® Best Practices Guide Version 3.3 and later - December, 2017 Networking QLogic 57800 2x10Gb SR/SFP+ + 2x1Gb BT Network Daughter Card, with SR Optics

The testing for this project will use Broadcom 57412 series I/O cards in the servers and the results will be equally valid for Copper or Optical variants. The I/O card will be connected to Riser 1. I/O card p/n: BCM957412A4120DLPC_08

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 94 of 242

The Broadcom 57400 series adapter (approx. 2017 launch date) which offer 10/25G connectivity. The specification exceeds that of the qualified (but older approx. 2010 launch data) Broadcom 57810 series I/O card, in several aspects, such as link speed and PCI backplane capacity. NO performance difference would be expected (at 10G) between the copper RJ 45 presentation cards and the SFP+ connected card.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 95 of 242

7.3 JUNIPER QFX5210 and EX4400 APPROVAL - SEP 2021 Funded custom testing SEP 2021, the diagram below shows an example for how these products were tested. But it is not a precise representation of all the variations. The switch configuration files based on this testing will be made publicly available, as part of VANILLA CONFIGS as there is no confidential information in the test system which has now been decommissioned. Until vanilla configs are updated, if they are required for a project, contact the author of this document.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 96 of 242

7.3.1 QFX QFX5120 CUSTOM TEST Tested in SEP 2021 (custom professional services funded testing) the QFX5120-48Y has proved itself to be a robust and capable platform, unlikely to discard packets once the egress buffer parameters are changed to allow the lossy buffer to consume 75% (20.5MB) instead of the default 31% (8.5MB), this clearly allows all ports to have a great dedicated buffer pool and/or to push deeper into shared buffer pool. THE devices were tested in several different scenarios:

SIMPLE L2 SWITCH minimal configuration

L3/L2 SWITCH

L3/L2 LACP CONNECTION TO NEXIS

L2 EDGE DEVICE UPLINKED to MLAG VRRP PAIR

L2 EDGE DEVICE UPLINKED to MLAG VRRP PAIR

L2/L3 MLAG/VRRP connection to NEXIS

VIRTUAL CHASSIS connection to NEXIS These buffer commands must be applied to minimize packet discard on the egress buffers:

set class-of-service shared-buffer egress buffer-partition lossless percent 5 set class-of-service shared-buffer egress buffer-partition lossy percent 75 set class-of-service shared-buffer egress buffer-partition multicast percent 20

This QFX5120-48Y and QFX5120-48T are now considered an APPROVED platform, this can also apply to all member of the QFX5120 SERIES. While they have different physical presentation SFP28 vs RJ45 the use the same internal chipset. Avid does not have this product family on Avid premises or have qualified vendor engineers, so all networking support must come from the switch vendor or customer. This is a Grade 3 capability switch with resiliency Grade 3. Grading explained in Section 1.2.1

7.3.2 EX4400 CUSTOM TEST Tested in SEP 2021 (custom professional services funded testing) the EX4400-48MP has shown itself to be a capable device for NEXIS dataflow despite a smaller 8MB shared packet buffer (approx. only 50% of this is available to EGRESS packets) compared to the QFX5120 SERIES products that have 32 MB of shared buffer. It was tested in several different scenarios:

L3/L2 SWITCH

L3/L2 LACP CONNECTION TO NEXIS

L2 EDGE DEVICE UPLINKED to MLAG VIRTUAL CHASSIS PAIR These buffer commands should be applied to reduce packet discard on the egress buffers:

set class-of-service shared-buffer 85

Any NEXIS clients connecting to this switch would still operate acceptably with standard buffer settings, but the enhanced setting eliminates packets discard ensuring that network diagnostics can be simpler.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 97 of 242

This EX4400-48MP is now considered an APPROVED platform. Avid does not have this product family on Avid premises or have qualified Juniper engineers, so all networking support must come from the switch vendor or customer. This is APPROVED as a Grade 2 capability switch with resiliency Grade 1. A single switch could not be tested to achieve a high resilience grade, but it is likely to be capable of Grade 3 resiliency based on the chipset and OS capabilities. Grading explained in Section 1.2.1 The testing used a EX4400-48MP, and we also simulated a EX4400-24MP. These are officially called the “EX4400 Multigigabit” (https://www.juniper.net/us/en/products/switches/ex-series/ex4400-multigigabit-enterprise-switch.html) The baseline EX4400 range has three models: EX4400-48F, EX4400-24P/T and EX4400-48P/T. (https://www.juniper.net/us/en/products/switches/ex-series/ex4400-ethernet-switch.html) All of them use the same ASIC but the MP versions have a slightly higher rated throughput of 1080Gbps vs. 912Gbps for the base EX4400, this is because of the higher RJ45 port speeds available on the MP versions. This approval applies to all versions as we only use 1G and 10G speeds during testing.

7.3.2.1 AVERAGE PACKET DISCARD This product discarded packets due to the bursty nature of NEXIS data flows during the testing the average discard percentages across all ports with NEXIS clients is shown in the table below.

AVERAGE BUFFER DISCARD 1G clients (NLE & DRONES)

10G clients

48-PORT MODE 0.27% 0.06%

24-PORT MODE 0.28% 0.08%

This device is not well suited to a heavy WRITE dataflow, but such workflows are rare, the QFX5120 SERIES would be a better choice. The average packet discard should be below 0.5% as calculated over a 10-minute period for any port to ensure correct operation.

99.0 LEGACY ISIS and Interplay Information This information will remain available in NETREQS V1.24

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 98 of 242

Appendix A - NEXIS Documentation - Landing pages Avid NEXIS v2018/19/20/21 Documentation http://avid.force.com/pkb/articles/en_US/user_guide/Avid-NEXIS-Documentation Avid NEXIS v7 Documentation http://avid.force.com/pkb/articles/en_US/user_guide/Avid-NEXIS-v7-Documentation Avid NEXIS v6 Documentation http://avid.force.com/pkb/articles/en_US/User_Guide/Avid-NEXIS-v6-Documentation

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 99 of 242

Appendix B - Switch configuration tips, good practices and Lessons from the field. This is not an exhaustive list of best practices, as these may vary from site to site based on customer policies and procedures and security requirements.

B.1 Document your configs with DESCRIPTIONS Use the description command to apply simple description to interfaces and VLANS such as AIRSPEED, MEDIA INDEXER, INTERPLAY ENGINE In Foundry the name or port-name command is used. A simple description conf t interface g1/1 description AIRSPEED CISCO PWDEMO-Cisco4948#conf t

Enter configuration commands, one per line. End with CNTL/Z.

PWDEMO-Cisco4948(config)#int t1/49

PWDEMO-Cisco4948(config-if)#desc CONNECTION TO ISIS VLAN LEFT

PWDEMO-Cisco4948(config-if)#int t1/50

PWDEMO-Cisco4948(config-if)#desc CONNECTION TO ISIS VLAN RIGHT

PWDEMO-Cisco4948(config-if)#exit

PWDEMO-Cisco4948(config)#exit

PWDEMO-Cisco4948#

B.1.2 Good documentation and config practices I reviewed some config recently (FEB2017) on a Cisco Catalyst C4500X VSS setup, with 3 C4948E edge switches and thought it worth adding the connect as section in this appendix, there is a bit of overlap with other sections in this appendix, and while this is based on Cisco Catalyst, it applies similarly to Cisco Nexus, albeit with some different terminology. The fundamental principles also applies (with appropriate changes) to Arista, Brocade, Dell, Juniper etc. ###### ###### ###### ###### ###### ###### ###### ###### ###### Looking at these configs I have some concerns, but I am not trying to shoot messenger, and they might also be a work in progress, in fact I do hope this is not the finished article. I am a stickler for in-config documentation, and I do not see much here, and what there is, is sparse. For me in-config documentation is a massive helper when it comes to fault diagnosis. A well-documented file is like having a torch in a dark tunnel, and logged events ideally to an external syslog server is a gold-plated bread-crumb trail. The level of in-config documentation I strive for is shown in my vanilla configs. I want to see named VLANs, described Switched Virtual interfaces, accurately described 10G interfaces for ALL devices with port information. “Issues” in the Core C4500X

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 100 of 242

VLANs are not named There is no differentiation on where the NEXIS connections are of upper or lower controller, or which port. Core switch port channels are not documented There is no RAPID PVST configured There is no long costing configured There is no root primary configured in the core switch for STP, yes it is still running and needs to be configured, even in a VSS, for when someone does something unexpected when plugging in another switch. There is no logging link event status configured on key links There is no logging server configured There is no ntp server configured There is no timezone or DST configured VLAN 1 should be shutdown “Issues” in the C4948E Edge switch VLANs are not named There is no RAPID PVST configured There is no long costing configured Core switch port channels are not documented There is no logging link event status configured on key links this is especially important for server class devices and uplinks Even plain NLE should be configured maybe just as NLE There is no logging server configured There is no ntp server configured There is no timezone or DST configured There should be a command to disable ip routing in all C4948E edged switches OPTIONAL There is no need to have an SVI configured in each VLAN The ip route command should be removed – would happen via step 9 OPTIONAL With the above two items there should be a corresponding ip default gateway command VLAN 1 should be shutdown There interface description of Server and clients and uplinks will help with identifying what SHOULD be connected, versus what MIGHT be connected, versus what is UNLIKLEY or SHOULD NOT be connected Now none of these suggestions will make the network run any faster, but it will definitely reduce your diagnostic time by 90% or more, in 90% or more diagnostic situations. I would say that is a pretty good investment. And even more important when you ask an external resource who is unfamiliar with the network and solution as a whole. ###### ###### ###### ###### ###### ###### ###### ###### ######

B.2 Setting Spanning tree to Rapid Spanning Tree CISCO PWDEMO-Cisco4948#conf t

Enter configuration commands, one per line. End with CNTL/Z.

PWDEMO-Cisco4948(config)#span

PWDEMO-Cisco4948(config)#spanning-tree mode rap

PWDEMO-Cisco4948(config)#spanning-tree mode rapid-pvst

PWDEMO-Cisco4948(config)#exit

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 101 of 242

PWDEMO-Cisco4948#

PWDEMO-Cisco4948#

FOUNDRY BigIron(config)# spanning-tree 802-1w

or BigIron(config)# vlan 10

BigIron(config-vlan-10)# spanning-tree rstp

B2.1 Spanning tree cost When costing up links this can be done on a per link basis or on a per VLAN basis across a given link PER LINK/INTERFACE PWDEMO-Cisco4948(config-if)#spanning-tree cost 10

PER VLAN, PER LINK.INTERFACE PWDEMO-Cisco4948(config-if)#spanning-tree vlan 10,20 cost 10

The value of 10 is appropriate when the short method is used spanning-tree path cost. When using the long method for spanning-tree path cost, a value if 5,000 is appropriate. This value is chosen so as not to reflect a pre-define value. ISIS can be described as a Layer 1.5 device, it is half switch, half hub! Hence when ISIS is connected to two switches and uses a FHRP setup, spanning tree will always need to be configured to achieve the required operation. Each customer will have slightly different preferences on which path to block, some will chose to block one of the ports facing ISIS other will choose the block some (the ISIS) VLANs via the SW-SW link. The option most suited will depend on which FHRP is deployed and how it is configured and the polices of the site, so no specific recommendation can be given in this document.

B.2.2 Spanning Cost type

Spanning tree cost can be Long or Short, different value applied as per the links below http://www.cisco.com/en/US/docs/switches/lan/catalyst4500/12.1/12.1e/command/reference/S1.html#wp1029022 Usage Guidelines

This command applies to all the spanning tree instances on the switch.

The long path cost calculation method uses all the 32 bits for path cost calculation and yields values in the range of 1 through 200,000,000.

The short path cost calculation method (16 bits) yields values in the range of 1 through 65,535.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 102 of 242

Examples

This example shows how to set the path cost calculation method to long:

Switch(config#) spanning-tree pathcost method long

Switch(config#)

This example shows how to set the path cost calculation method to short:

Switch(config#) spanning-tree pathcost method short

Switch(config#)

http://en.wikipedia.org/wiki/Spanning_Tree_Protocol#Data_rate_and_STP_path_cost

Data rate and STP path cost

The table below shows the default cost of an interface for a given data rate.

Data rate STP Cost (802.1D-1998) STP Cost (802.1t-2001)

4 Mbit/s 250 5,000,000

10 Mbit/s 100 2,000,000

16 Mbit/s 62 1,250,000

100 Mbit/s 19 200,000

1 Gbit/s 4 20,000

2 Gbit/s 3 10,000

10 Gbit/s 2 2,000

B.3 SET primary switch as STP master root primary Spanning tree settings must be done for each VLAN PWEMO-Cisco4948#conf t

PWDEMO-Cisco4948(config)#spanning-tree vlan [NUM] root primary

PWDEMO-Cisco4948(config)#exit

PWDEMO-Cisco4948#

The command that actually gets entered in to Cisco running config will look like this spanning-tree priority 24576 but the number will be change depending on the VLAN numbers. FOUNDRY BigIron(config)#spanning-tree priority 24576

Syntax: [no] spanning-tree [forward-delay <value>] | [hello-time <value>] | [maximum-age <value>] | [priority <value>] Here is the syntax for port STP parameters. Syntax: [no] spanning-tree ethernet | pos <portnum> path-cost <value> | priority <value>

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 103 of 242

priority: Possible values: 1 – 65535. Default is 32768. A higher numerical value means a lower priority; thus, the highest priority is 0.

B.4. SET secondary switch as STP root secondary Spanning tree settings must be done for each VLAN PWEMO-Cisco4948#conf t

PWDEMO-Cisco4948(config)#spanning-tree vlan [NUM] root secondary

PWDEMO-Cisco4948(config)#exit

PWDEMO-Cisco4948#

The command that actually gets entered into Cisco running config will look like this spanning-tree priority 28672 but the number will be changed depending on the VLAN numbers FOUNDRY BigIron(config)#spanning-tree priority 28672.

B.5 Deploy BPDU guard on all ports that use PORTFAST Ensure that all appropriate ports that use the PORTFAST setting are protected against BPDUs.

Note: These recommendations in this subsection originated with ISIS 7x00 and Cisco Catalyst Switches and may not apply equally to use with AVID NEXIS or Cisco NEXUS, or may have alternative commands listed later in this subsection, that will supersede earlier information.

The PORTFAST setting should only be used on ports 1G or 10G that connect clients and servers

10G ports which face ISIS switches should NOT use the portfast setting

10G ports which connect to other switches (e.g. 4900M to 4900M inter-switch link, or 4900M to cascaded 4948) should NOT use the portfast setting

BPDU Guard will administratively shutdown any port which receives BPDUs. LAB-4948-10GE-S(config)#spanning-tree portfast uard default

This is a global command. Also consider that when STP BPDU guard disables the port, the port remains in the disabled state unless the port is enabled manually. You can configure a port to re-enable itself automatically from the errdisable state. Issue these commands, which set the errdisable-timeout interval and enable the timeout feature: Cisco IOS Software Commands CatSwitch-IOS(config)# errdisable recovery cause bpduguard

CatSwitch-IOS(config)# errdisable recovery interval 400

Note: The default timeout interval is 300 seconds and, by default, the timeout feature is disabled.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 104 of 242

For more information see: http://www.cisco.com/en/US/tech/tk389/tk621/technologies_tech_note09186a008009482f.shtml

[url active MAY 2011] Note spanning-tree bpduguard can be enabled individually on any interface that is not protected by PORTFAST

BPDUGUARD should be disabled on all switch interfaces that face ISIS 7000 ISS ports. As ISIS 7000 ISS will transparently pass BPDU there can be some undesirable effects, such as port shutdown when more than one network switch is connected such as in and FHRP (HSRP/GLBP/VRRP etc.) deployment.

B5.1 Use ROOT GUARD on any interfaces that cascade to other switches Even though the root Primary and root secondary switch may be set, there are still situation which they can be superseded. ROOT GUARD can circumvent this. For example, in a typical 4900M HSRP configuration with cascaded 4948 switches this can be enabled on all ports 4900M ports which downlink to a 4948 or that are unused. spanning-tree guard root LAB-4948-10GE-S(config)#interface TenGigabitEthernet1/4

LAB-4948-10GE-S(config-if)# spanning-tree guard root

LAB-4948-10GE-S(config-if)#

CISCOLAB-4948-10GE-S(config-if)#do sh run int t1/4

interface TenGigabitEthernet1/4

switchport access vlan 10

switchport mode access

spanning-tree guard root

For more information see: http://www.cisco.com/en/US/tech/tk389/tk621/technologies_tech_note09186a00800ae96b.shtml

[url active MAY 2011] Using both on an interface is not required as ROOT GUARD is subordinate to BPDU GUARD spanning-tree bpduguard enable

spanning-tree guard root

What Is the Difference Between STP BPDU Guard and STP Root Guard? BPDU guard and root guard are similar, but their impact is different. BPDU guard disables the port upon BPDU reception if PortFast is enabled on the port. The disablement effectively denies devices behind such ports from participation in STP. You must manually re-enable the port that is put into errdisable state or configure errdisable-timeout. Root guard allows the device to participate in STP as long as the device does not try to become the root. If root guard blocks the port, subsequent recovery is automatic. Recovery occurs as soon as the offending device ceases to send superior BPDUs.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 105 of 242

ROOT GUARD should be disabled on all switch interfaces that face ISIS 7000 ISS ports. As ISIS 7x00 ISS will transparently pass BPDU there can be some undesirable effects when more than one network switch is connected such as in and FHRP (HSRP/GLBP/VRRP etc.) deployment.

B5.2 Using spanning-tree port type edge with Cisco Nexus and AVID NEXIS Most NEXIS solutions that are deployed on Cisco NEXUS switches will benefit from using this command toward all storage engines and all NLE clients. should use this command as they should connected as fast as possible and not wait for spanning-tree normal processes. To configure an interface connected to a host as an edge port, which automatically transitions the port to the spanning tree forwarding state without passing through the blocking or learning states, use the spanning-tree port type edge command. To return the port to a normal spanning tree port, use the no spanning-tree port type command. Sometimes if bpduguard is deployed as a global command it one might also see: spanning-tree bpduguard disable But this does not enable the fast transition of port coming up. The basic command is shown below switch(config-if)# spanning-tree port type edge Additionally, bpduguard default can also be added to ensure the port shots down as “err disabled” if a switch is connected: switch(config-if)# spanning-tree port type edge bpduguard default

B.6 Use the no shutdown command on all VLANs Because new VLANs are shutdown [off] by default, make sure you use the no shutdown command. Layer 2 interfaces are on by default Layer 3 interfaces (routed or switched) are off by default.

PLEASE DO MAKE SURE THAT VLAN1 IS SHUTDOWN

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 106 of 242

B.7 Use the shutdown command on all unused interfaces Because all Layer 2 interfaces are on by default, it is a good security practice to use the shutdown command, and add a description as SHUTDOWN CISCO PWDEMO-Cisco4948#conf t

Enter configuration commands, one per line. End with CNTL/Z.

PWDEMO-Cisco4948(config)#int g1/40

PWDEMO-Cisco4948(config-if)#desc SHUTDOWN – INTERFACE NOT USED

PWDEMO-Cisco4948(config-if)#exit

PWDEMO-Cisco4948(config)#exit

PWDEMO-Cisco4948#

….if a port is not being used .

B.8 Enable secret It is important to apply an enable secret to all configs, usually during the install phase this will be a simple password such as avid which will be changed by the customer after system handover. Don’t waste time with an enable password as this offers backward compatibility with Pre 12.x IOS images (last used in the 1990s!), never deployed with any Cisco Catalyst 4948 or 4900M, and it just adds confusion, also it is superseded by an enable secret anyway.

B.9 Password encryption Encrypting passwords is a good thing to do, but possibly this should only be done after system handover. PWDEMO-Cisco4948(config)#service password-encryption

This will apply Cisco level 7 encryption to all clear text passwords such as line console and VTY The enable secret is encrypted at Cisco level 7 by default

B.10 Enable telnet Telnet is not enabled in a Cisco 4948 by default but is enable in a Foundry by default A Cisco switch will need the following commands to enable telnet line vty 0 4

password avid

login

A Cisco switch will need an enable secret before allowing telnet access, this is in addition to a telnet password, but the can be the same e.g. avid.

B.11 Enable synchronous logging When synchronous logging is enabled, information items sent to console will not interrupt the command you are typing. The command will be moved to a new line line con 0

logging synchronous

stopbits 1

line vty 0 4

password avid

login

!

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 107 of 242

B.12 GET A PROPER TERMINAL EMULATOR Hyper terminal which comes with Windows is liability. It may corrupt data outside the main display window. Ditch it for one of those below.

B.12.1 PUTTY for Windows Putty is freeware, and v0-60 (or later) supports serial ports too, telnet, SSH and more. This product can be configured with a large scroll back buffer. Can be re-sized and run multiple instances to allow communications with multiple devices concurrently. Make sure you enable session logging to a unique filename for each device.

B.12.2 ITERM2 for MAC ITERM2 for MAC is an excellent multi tab/window terminal emulator (freeware) that can be configured for session logging, but creates a new file for each session. Telnet, and SSH, with serial connectivity for the brave via a Sunflower cable.

B.12.3 MOBAXTERM for Windows MOBAXTERM is another new excellent freeware (and premium version) tool for Windows that allows multi tab/window terminal emulator, telnet, SSH and so many more, with unique session logging and COLOUR. The COLOUR is automatic and REALLY helpful.

B.13 Logging

• Logging is a great diagnostic tool – Logging is normally to a console session only – Logs do not persist a power cycle or reload – Logging can be sent to and external server

• A syslog server • Logging can be sent to telnet session

– Issue the command terminal monitor – REMEMBER to turn it off!!

• no terminal monitor

B.14 Using a Syslog Server • Many syslog implementations

– Usually part of a commercial SNMP packages – Freeware applications are numerous

• Personal favourite is KIWI Syslog Daemon – Which will also perform as a BASIC SNMP trap manager

» Just to prove they are being sent!....and received!! – Cisco commands

logging trap debugging >>> THIS IS WHAT TO SEND logging 10.134.87.87 >>> THIS IS WHERE TO SEND

• Logging is only useful with time stamps – That means the clock must be configured – And the correct commands exist in the config file – Which is the most useful output below?

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 108 of 242

7w4d: %SYS-5-CONFIG_I: Configured from console by vty0 (10.134.132.86) 7w4d: %SYS-5-CONFIG_I: Configured from console by vty0 (10.134.132.86) *Sep 14 15:39:24: %SYS-5-CONFIG_I: Configured from console by vty0 (10.134.132.86) *Sep 14 15:39:46: %SYS-5-CONFIG_I: Configured from console by vty0 (10.134.132.86) Aug 5 15:15:56.124 UTC: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/2, changed state to down Aug 5 15:15:58.472 UTC: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/2, changed state to up

– Sep 14 at 15:39 is a whole lot more useful than 7 weeks and 4 days!! Also see: How to configure logging in Cisco IOS https://supportforums.cisco.com/document/24661/how-configure-logging-cisco-ios

B14.1 Freeware logging servers Linux offers this by default, but it may have to be enabled and there are many logging servers for Windows, but many of the allegedly free systems are not free for commercial use. But the one below looks like it is TOTALLY free Visual Syslog Server for Windows: Syslog Server for Windows with a graphical user interface http://maxbelkov.github.io/visualsyslog/ Also this TFTP application provide an Syslog server too (64 bit version is available). http://tftpd32.jounin.net/tftpd32.html KIWI syslog used to be FREE too, but since it was purchased by SOLARWINDS that has changed to a 14 days trial . Also consider KLEVER SOFTWARE; free syslog server. I am a great fan of KLEVER software for TFTP too with PUMPKIN. http://kin.klever.net/klog#.WXcRQdPytmM

B.15 Timestamps • service timestamps log uptime

7w4d: %SYS-5-CONFIG_I: Configured from console by vty0 (10.134.132.86)

• service timestamps log datetime *Sep 14 15:39:24: %SYS-5-CONFIG_I: Configured from console by vty0 (10.134.132.86)

• Also a command for Debug statements – service timestamps debug uptime [datetime] – This parameter needs to be set to if you want any sensible output when using debug

commands

– The default is uptime as no time may be set!! service timestamps debug datetime

service timestamps log datetime

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 109 of 242

or even service timestamps debug datetime msec localtime show-timezone

service timestamps log datetime msec localtime show-timezone

B.16 Setting the Time The time can be controlled manually or by an NTP server. To manually set the clock, use the command example below. This method usually loses during a restart or power cycle. Switch#clock set 17:30:00 14 SEP 2012

– NOT an exec level command! The command below can be used for NTP Switch(config)#ntp server 10.184.106.99

Or depending on NTP setup Switch(config)#ntp peer 10.184.106.99

Peers are a class that allows for both responses to NTP Requests as well as acceptance of NTP Updates, while an NTP Server will only respond to requests and not permitting updates. There is more information available from the INE's CCIEBlog -URL - http://blog.internetworkexpert.com/tag/ntp/ - that may clear up some of the intricate detail.

Should also set the timezone and daylight savings parameters (or just use UTC), below are command that work in CISCO CATALYST, Cisco Nexus has different syntax, see section B.16.1 clock timezone GMT 0

clock summer-time BST recurring last Sun Mar 3:00 last Sun Oct 3:00

For Europe clock timezone CET 1

clock summer-time CEST recurring last Sun Mar 2:00 last Sun Oct 2:00

For USA –

clock timezone EST -5

clock summer-time EDT recurring 2 Sun Mar 2:00 1 Sun Nov 2:00 60

*NOTE this example specifies and offset of 60 minutes, which is the default when not specified. For Sydney Australia – clock timezone AEST 10 0

clock summer-time AEDT recurring 1 Sun Oct 2:00 1 Sun Apr 3:00

For Qatar (Arabian Standard Time) no daylight saving time change. clock timezone AST 3

See articles at: http://www.networkworld.com/community/node/11875

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 110 of 242

And http://www.timeanddate.com/library/abbreviations/timezones/ And http://www.cisco.com/en/US/docs/ios/12_2/configfun/command/reference/frf012.html http://www.cisco.com/en/US/docs/voice_ip_comm/bts/4.1/command/reference/91TMZ.pdf Also consider using the update calendar command for devices like C49XX series which has in internal H/W clock

SWITCH> clock update-calendar

B.16.1 Command for Cisco NEXUS Must use Hours and Minutes even if minutes is zero otherwise command is rejected For Europe clock timezone CET 1 0

And then for automatic summertime clock adjustment clock summer-time CEST 5 sun mar 02:00 5 sun oct 02:00

Must have week numbers of month 1= first 5= last

B.17 Show tech support for CATALYST **** SEE Section B.39 for Cisco NEXUS One way to extract a lot of information form a switch is to use show tech-support

• A tool on Cisco and Foundry to do a dump of the system and all the status information – Shows state of all interfaces in brief and detail

• Another reason why interface descriptions are important! – More information from Cisco than Foundry

• Approx 2MB from a 4948! – Can be piped to a file on a tftp server – 2611XM-BLUE#show tech-support | redirect

tftp://10.124.87.87/redirect-sh-tech.txt

– Can be captured into a putty log file via telnet ( or other suitably capable telnet application).

B17.1 What is listed? What is listed varies between switch models and s/w versions, but below is an indication

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 111 of 242

show clock show version show running-config show stacks show interfaces show controllers show user show data-corruption show file systems show bootflash: all show cat4000_flash: all show memory statistics show process memory show process cpu show process cpu history show cdp neighbors detail show diagnostic result module all detail show environment show interfaces counters errors show interfaces status

show interfaces trunk show logging show module show mac-address-table count show platform chassis show platform cpu packet statistics show platform cpu packet driver show platform crashdump show platform hardware interface all VERY LONG SECTION!!! show platform health show platform environment variables show platform portmap show platform software interface all VERY LONG SECTION!!! show power detail show spanning-tree summary show vlan show buffers show inventory show region

B17.2 Show tech-support - CAVEATS • Use with caution from the Console port

– Output of a 2MB (C4948) file will be very slow and cannot be interrupted – It will take SEVERAL cups of coffee to finish at 9600bps!! – Much faster via telnet at Fast Ethernet speed – OK to PIPE from console port to TFTP server. – 2611XM-BLUE#show tech-support | redirect

tftp://10.134.97.97/redirect-sh-tech.txt

– If capturing by telnet and copy/pasting into a text file, make sure application has sufficient scroll buffer, Putty 0.6 can be configured for large amounts, or set up the putty log file to capture it for you.

– HyperTerminal or Telnet from Window CLI ….NOT ADVISED – Show Tech support on NEXUS 9K an create file sized of up to 800MB!!!! See section

B.39 for a NEXUS alternative method

B17.3 How long does it take?

• Telnet Access to switch and PIPE via Gigabit Ethernet to TFTP server – about 10 seconds

• CLI access to a switch and PIPE via Fast Ethernet (management port) to TFTP server – About 60 seconds

• TELNET to CLI (and capture in putty log file) – About 3 seconds at Gigabit Ethernet or 15 seconds at Fast Ethernet

• Console to CLI – About 2100 seconds, yes that is 35 Minutes! Time for several coffees or even

lunch!!

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 112 of 242

B17.4 useful show commands When show tech support is just too much information, as on NEXUS switches, the command below can be very useful SECTION MOSTLY DELETED SEE SECTION B.39.1 NEXUS 93xxx USEFUL COMMANDS FROM SHOW TECH. for a more complete list show version

show module

show interface status

show interface description

show running-config

show cdp neighbor

show cdp neighbor detail

show interface counter errors < do twice 10 minutes apart> show Etherchannel summary | show portchannel summary

show hsrp | glbp | vrrp brief

Show spanning-tree

SECTION MOSTLY DELETED SEE SECTION B.39.1 NEXUS 93xxx USEFUL COMMANDS FROM SHOW TECH. for a more complete list

B17.5 TFTP tools There are many free tools: One of my favourites for Windows is PUMKIN from KLEVER SOFTWARE Apparently this is now available for MAC OSX too http://kin.klever.net/pumpkin#.WXcSDNPytmN For MAC OSX, it has a built in tftp server, but it needs CLI access, but I found this TFTP “application” which does the hard work. https://www.macupdate.com/app/mac/11116/tftpserver# http://ww2.unime.it/flr/ Also consider TFTP application provide an tftp server (and sysylog, DHCP etc) too (64 bit version is available). http://tftpd32.jounin.net/tftpd32.html Tftpd32 is a free, opensource IPv6 ready application which includes DHCP, TFTP, DNS, SNTP and Syslog servers as well as a TFTP client. The TFTP client and server are fully compatible with TFTP option support (tsize, blocksize and timeout), which allow the maximum performance when transferring the data. Some extended features such as directory facility, security tuning, interface filtering; progress bars and early acknowledgments enhance usefulness and throughput of the TFTP protocol for both client and server. The included DHCP server provides unlimited automatic or static IP address assignment. Tftpd32 is also provided as a Windows service. Tftpd64 is the same application compiled as a 64 bits application.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 113 of 242

B.18 Handover Practices One way to ensure easy review Cisco config file documentation would be to collect the information below with three commands as part of the handover pack. -- show version -- show running-config -- show interfaces status The latter command will show which interfaces are connected and which have descriptions, so connected interfaces without descriptions can be easily identified without Below is a sample Port Name Status Vlan Duplex Speed Type

Gi1/1 WEBSERVER connected 51 a-full a-1000 10/100/1000-TX

Gi1/2 ** MC Nitris 1 notconnect 51 auto auto 10/100/1000-TX

Gi1/3 ** Protools connected 51 a-full a-1000 10/100/1000-TX

Gi1/4 ** MC Nitris 3 connected 51 a-full a-1000 10/100/1000-TX

Gi1/5 ** DS connected 51 a-full a-1000 10/100/1000-TX

Gi1/6 notconnect 51 auto auto 10/100/1000-TX

Gi1/7 >> Interlink VLAN connected 410 a-full a-1000 10/100/1000-TX

Gi1/8 notconnect 51 auto auto 10/100/1000-TX

Gi1/19 notconnect 51 auto auto 10/100/1000-TX

Gi1/20 DOWNLINK TO 3750 V connected 51 a-full a-1000 10/100/1000-TX

Gi1/21 notconnect 52 auto auto 10/100/1000-TX

Gi1/22 connected 52 a-full a-1000 10/100/1000-TX

Gi1/23 connected 52 a-full a-1000 10/100/1000-TX

Gi1/24 notconnect 52 auto auto 10/100/1000-TX

Gi1/25 connected 52 a-full a-1000 10/100/1000-TX

The additional commands are optional -- show cdp neighbors detail

-- show spanning-tree summary

-- show vlan

-- show logging

B.19 Cisco Catalyst 49XX setting of the CONFIG register Cisco 4948 switches supplied by Avid are configured with a Configuration Register value of 0x2101, which means the switch will boot from the first IOS that appears in bootflash. Cisco instructs you to set the Configuration Register to 0x2102, which means the switch will look for a boot string that points to the IOS from which to boot.

B.20 Multicast Propagation Does Not Work in the same VLAN in Catalyst and NEXUS Switches Multicast is back! It is used for internode communication in Interplay Common services V1.3, which is a key component for Interplay Central, Interplay Sphere and Interplay MAM solutions. The default address used is 226.94.1.1, unless the administrator configures a different address. This Multicast Propagation requirement also applies to Interplay Media Indexer NOMI configurations beginning V3.5. Only layer 2 communication is required, but if nodes are on different switches connected by an inter-switch link it may not work as expected, this is due to IGMP snooping features which are enabled by default on some switches. As a two-switch configuration supported by a First Hop Resiliency Protocol (FHRP) such as HRSP, GLBP or VRRP, this could become a common challenge.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 114 of 242

Beginning Interplay 3.0 the mechanisms for media indexers to communicate with each other started to change changed, beginning Interplay V3.5, JINI is no longer used and the ASF (Avid Service Framework) is not used.

amq default which is multicast://239.255.2.3:6155 Beginning Interplay V3.5 everything that was using ASF to keep two or more server Media Indexers (in a High Availability Group that is now replaced by a Network of Media Indexers (NOMI)) synchronized and ready for failover is now done using the local multicast introduced with Interplay V3.0. These Multicast messages are only needed in the Interplay VLAN so no Multicast Routing is required. This is one reason why Interplay 2.7.x can no longer be used with Interplay 3.5. Also consider this article for Media Indexer NOMI http://avid.force.com/pkb/articles/en_US/How_To/Multicast-Time-to-Live-adjustment

Note that the local Media Indexers on the editors do not require Multicast communication with the servers. Multicast communication is only required between the Media Indexer servers. The multicast address used is 239.255.2.3 on UDP port 6155.

Note: for Interplay Central Services ICS 1.4 and 1.5 (H1/2013) the default multicast address is 239.192.1.1 corosync_mcast_addr=${corosync_mcast_addr:-"239.192.1.1” Beginning V2.0 (approx. 2014/2015) ICS was renamed MediaCentral Server and the last version of this product was V2.10 in MAR 2017 (initial release, final release 2.10. OCT 2020).

Media Central Cloud UX Server Kubernetes does not use multicast. Keepalived is configured to use unicast by default (multicast configurations are not supported). Media Central Cloud UX V2018.1 initial release AUG 2018

For Cisco Catalyst the quick fix is: SWITCH# (config)#int vlan 30

SWITCH# (config-if)# ip pim sparse-dense-mode

This must be applied in the appropriate VLAN, it does not have to be applied to all VLANs. The above example assume that VLAN 30 is the location for the Interplay Common Services “cluster” of nodes The URL below contains more detailed explanation

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 115 of 242

http://www.cisco.com/en/US/products/hw/switches/ps708/products_tech_note09186a008059a9df.shtml or http://www.cisco.com/c/en/us/support/docs/switches/catalyst-6500-series-switches/68131-cat-multicast-prob.html#igmp However, it might be preferable to use Solution 2 or Solution 3 from this article Document ID: 68131 This document discusses a common problem that occurs when you deploy the multicast application for the first time on a Cisco Catalyst switch network and the multicast fails to work. In addition, some servers/applications that use multicast packets for the cluster/high-availability operation can fail to work if you do not configure the switches appropriately. The document covers this issue as well. Below is an extract from that document ID: 68131 manually edited/“Tailored” toward Avid configuration for C45xx/C49XX switches. Solution 1: Enable PIM on the Layer 3 Router/VLAN Interface All Catalyst platforms have the ability to dynamically learn about the mrouter port. The switches passively listen to either the Protocol Independent Multicast (PIM) hellos or the IGMP query messages that a multicast router sends out periodically. This example configures the VLAN 30 switched virtual interface (SVI) on the Catalyst 4500 with ip pim sparse-mode. Switch1#show run interface vlan 30

!

interface Vlan1

ip address 192.168.30.1 255.255.255.0

ip pim sparse-mode

end

Switch 1 now reflects itself (Actually the internal router port) as an

Mrouter port.

Switch1#show ip igmp snooping mrouter

vlan ports

-----+----------------------------------------

1 Router

Switch 2 receives the same PIM hellos on its T1/1 interface. So it assigns

that port as its Mrouter port.

Switch2#show ip igmp snooping mrouter

Vlan ports

---- -----

1 Te1/1(dynamic)

Solution 2: Enable IGMP Querier Feature on a Layer 2 Catalyst Switch The IGMP querier is a relatively new feature on Layer 2 switches. When a network/VLAN does not have a router that can take on the multicast router role and provide the mrouter discovery on the switches, you can turn on the IGMP querier feature. The feature allows the Layer 2 switch to proxy for a multicast router and send out periodic IGMP queries in that network. This action causes the switch to consider itself an mrouter port. The remaining switches in the network simply define their respective mrouter ports as the interface on which they received this IGMP query. Switch2(config)#ip igmp snooping querier

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 116 of 242

Switch2#show ip igmp snooping querier

Vlan IP Address IGMP Version Port

-------------------------------------------------------------

30 192.168.30.2 v2 Switch

Switch 1 now sees port T1/1 linking to Switch 2 as an mrouter port.

Switch1#show ip igmp snooping mrouter

vlan ports

-----+----------------------------------------

1 T1/1

When the source on Switch 1 starts to stream multicast traffic, Switch 1 forwards the multicast traffic to the Receiver 1 found via IGMP snooping (i.e., out port Te 1/8) and to the mrouter port (i.e., out port Te 1/1).

Note: a Layer 2 (only or a L3 capable device operating in L2 only mode) catalyst switch will not have a multicast querier IP address.

Solution 3: Configure Static Mrouter Port on the Switch The multicast traffic fails within the same Layer 2 VLAN because of the lack of an mrouter port on the switches, as the Understand the Problem and Its Solutions section discusses. If you statically configure an mrouter port on all the switches, IGMP reports can be relayed in that VLAN to all switches. As a result, multicasting is possible. So, in the example, you must statically configure the Catalyst 4500 Switch to have Tengigabitethernet 1/1 as an mrouter port. In this example, you need a static mrouter port on Switch 2 only:

Switch2(config)#ip igmp snooping vlan 30 mrouter interface

Tengigabitethernet 1/1

Switch2#show ip igmp snooping mrouter

Vlan ports

---- -----

1 Te 1/1(static)

B.20.1 Multicast Propagation - an Avid perspective The issue is explained from an Avid perspective here and applied equally to MCS servers connected across two switches or Media Indexer servers can be explained with the help of the diagram below. In the early days of Ethernet, multicast packets (to be correct they should be termed FRAMES, but the two terms will be used interchangeably) they were treated a little like broadcast packets, but as multicast become more popular that posed challenges for bandwidth use and CPU cycle use on clients that did not need to receive multicast frames. One of the tools

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 117 of 242

In the early days of Ethernet, a multicast frame from SOURCE-1 one would be received by RECIEVER 1-4, and a multicast frame from SOURCE-2 one would be received by RECIEVER 1-4. This was not scalable. Also consider that a multicast capable device can be both and source and a receiver. With the Advent of IGMP Snooping, the default state became NOT TO ACCEPT to multicast frames from another switch without some sort of pre-configuration to do so. Hence the current state in most switches arranged as above is: Receiver 3 will be forwarded multicast frames from Source 1 as on the same switch, but not from Source 2 because it is on a different switch. Receiver 4 will be forwarded multicast frames from Source 2 as on the same switch, but not from Source 1 because it is on a different switch. To enable the Media Indexers (or Media Central Servers) to communicate with multicast across a switch boundary then one of the methods described in the articles referenced in this section B.20 must be deployed.

B.20.2 – Nexus switches Multicast Propagation A similar problem should not exist with Nexus switches which for a vPC pair. It is quite possible that similar fixes will work but there is not an “identical” article for Nexus as for Catalyst. This issue was encountered in a major broadcaster during SEP2016 consultancy where Interplay 3.5 was being deployed on a system using A Nexus 5672 vPC Pair along with Nexus 2248TPE fabric extenders. It also affected EVS products which were unable to use multicast correctly The articles below, reference similar issues, but the Nexus 5000 documentation from Cisco is not sufficiently clear with regards to configuring IGMP snooping to overcome the issue

here are the articles found:

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 118 of 242

http://blog.alainmoretti.com/pim-ssm-through-nexus-vpc/ http://blog.lah.io/2014/01/troubleshooting-cisco-nexus-5500-igmp.html and these are the VLANs where multicast needs to be propagated within VLANs (not routed): 1241 1251

These commands were entered on both N5672, multicast routing was not enabled, it is not required, using PIM in this way allows the L2 features and/or “side effects” of PIM to be used to address the problem of insufficient “local” multicast propagation. conf t

feature pim

int vl 1241

ip pim sparse-mode

int vl 1251

ip pim sparse-mode

The issues was resolved after these commands were entered into BOTH Nexus 5672 switches. Interplay NOMI and the EVS devices were able to communicate within their own VLAN. Also see http://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus5000/sw/configuration/guide/cli/CLIConfigurationGuide/IGMPSnooping.html It is possible that command below will have the net effect as ip pim sparse-mode in a VLAN. switch(config-vlan)# ip igmp snooping querierIP-address

Configures a snooping querier when you do not enable PIM because multicast traffic does not need to be routed. The IP address is used as the source in messages. The default is disabled.

At the time of writing (MAR2017) this command has not been used/tested by Avid. Looking at this document about NEXUS 9000 https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/interfaces/configuration/guide/b_Cisco_Nexus_9000_Series_NX-OS_Interfaces_Configuration_Guide_7x/b_Cisco_Nexus_9000_Series_NX-OS_Interfaces_Configuration_Guide_7x_chapter_01000.html vPC Multicast—PIM, IGMP, and IGMP Snooping The software keeps the multicast forwarding state synchronized on both of the vPC peer devices. The IGMP snooping process on a vPC peer device shares the learned group information with the other vPC peer device through the vPC peer link; the multicast states are always synchronized on both vPC peer devices. The PIM process in vPC mode ensures that only one of the vPC peer devices forwards the multicast traffic to the receivers.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 119 of 242

Each vPC peer is a Layer 2 or Layer 3 device. Multicast traffic flows from only one of the vPC peer devices. You might see duplicate packets in the following scenarios: Also for NXOS 9.x See Similar article https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/92x/multicast/b-cisco-nexus-9000-series-nx-os-multicast-routing-configuration-guide-92x/b-cisco-nexus-9000-series-nx-os-multicast-routing-configuration-guide-92x_chapter_0110.html B.20.2.1 – Field Knowledge NEXUS & Multicast PART 1 Depending on the setup VPC/HSRP or HSRP only different command may be necessary for NEXUS 9000 deployments. Config

Vlan configuration <vlan id>

ip igmp snooping querier <ip of the gateway in the vlan>

ip igmp snooping fast-leave

A field engagement with FastServe and Pivot apparently needed these commands, but it was never conclusively proved that was the case. This should be done on all switches. The example below uses the VIP of the HSRP supported SVI

Config t

vlan config 103

ip igmp snooping querier 10.1.3.1

It is unclear whether as SVI must be configured ion the L2 edge switch but as a precautionary measure I would advise this is also done.

Note: the IP address is important and would run on the L3 switch, but possibly and the L2 only switch (but NEXUS does not run in a L2 only mode like a catalyst, so and IP address is required and may be different on all switches in the VLAN. The querier address is the local address in a VLAN that will send and receive the messages. When a querier address is configured even if the LEAVE/JOIN messages are going to the Mrouter they should be sniffed (an acted upon) by the local device. However, Link level) Layer 2 broadcasting messages may not be looking for a querier to ask to join because they are not looking for a multicast stream or receive, unless the stream has been DELEIBERATELY put onto 239.x.x.x which means it should never be routed.

USEFUL NEXUS COMMANDS FOR MULTICAST DEBUGGING The command below may be useful, to see what is happening in respect of L2 multicast. In some cases use them with “pipes” to hone in on specific IP addresses. mtrace events for IGMP process show ip igmp internal event-history igmp-internal | no-more

show ip igmp internal event-history debugs | no-more

show ip igmp route vrf all | no-more

show ip igmp interface vrf all | no-more

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 120 of 242

show ip igmp snooping vlan <x> | no-more

show ip igmp internal | no-more

show ip igmp internal errors | no-more

show ip igmp groups vrf all summary | no-more

show ip igmp internal event-history errors | no-more

show ip igmp internal event-history msgs | no-more

show ip igmp internal event-history vrf | no-more

show ip igmp internal event-history events | no-more

show ip igmp internal event-history policy | no-more

policy events for IGMP process show ip igmp internal event-history cli | no-more

show ip igmp snooping groups detail | no-more

show ip igmp snooping explicit-tracking | no-more

show ip igmp snooping internal event-history vlan | no-more

PING MULTICAST 224.0.0.1 (ALL HOSTS)

PING MULTICAST 224.0.0.2 (ALL ROUTERS)

ping multicast 224.0.0.1 int vl [number] count 1

Some of these commands will produce 100,000 plus lines so best to have putty logging (printable output) setup to harvest to a text file. NOTE: The two command that seem to give the best “short” output are: show ip igmp snooping groups detail | no-more

show ip igmp snooping explicit-tracking | no-more EXAMPLE CONFIG

THIS SYSTEM has 4 SWITCHES 2 x NEXUS 93180YC as a VPC PAIR LAYER 3 CORE 2 x NEXUS 9348 as STANDALONE L2 EDGE MEDIA INDEXER is connected on the NEXUS 9348 as STANDALONE L2 EDGE

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 121 of 242

PRODUCTION ENGINE is on the NEXUS 93180YC as a VPC PAIR LAYER 3 CORE SW1 CORE

conf

int lo9

desc LOOPBACK FOR MCAST ip igmp snooping querier

ip address 1.1.1.101/32

exit

vlan configuration 10,20,30

ip igmp snooping querier 1.1.1.101

end

SW2. CORE

conf

int lo9

desc LOOPBACK FOR MCAST ip igmp snooping querier

ip address 1.1.1.102/32

exit

vlan configuration 10,20,30

ip igmp snooping querier 1.1.1.102

end

SW3. EDGE

conf

int lo9

desc LOOPBACK FOR MCAST ip igmp snooping querier

ip address 1.1.1.103/32

exit

vlan configuration 10,20,30

ip igmp snooping querier 1.1.1.103

end

SW4. EDGE

conf

vlan configuration 10,20,30

ip igmp snooping querier 1.1.1.104

exit

int lo9

desc LOOPBACK FOR MCAST ip igmp snooping querier

ip address 1.1.1.104/32

end

TO REMOVE

no vlan configuration 10,20,30

Some command that might help in Debugging Multicast L2 operation are: This Windows program that might help one understand multicast better but will need some “playtime” on a suitable network, it supports Win 10 but not explicitly and of the server OS. MPING https://www.microsoft.com/en-us/download/details.aspx?id=52307 OMPING

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 122 of 242

https://www.claudiokuenzler.com/blog/656/test-multicast-connectivity-working-omping-linux I have not had the opportunity to trial them at the time of writing (DEC 2019). We found that Pivot/FastServe communication would fail if ip pim sparse-mode was not configured on the (VLAN103) NEXUS CORE switch(es) along with the igmp querier.

Note: While using the feature PIM technically requires the enhanced licensing for NEXUS switches, only the most basic features of PIM necessary to “apparently” correctly deal with L2 multicast are used, and no multicast routing is involved, so morally this is not exploiting the “honor based” system. If only good reliable, tried and tested application note were provided by Cisco (and other vendors) this would not be necessary (maybe it does exist but is well hidden amongst the plethora of other similar article and internet searches cannot dive deep enough).

Licensing Requirements for PIM:

PIM requires an Enterprise Services license. For a complete explanation of the Cisco NX-OS licensing scheme and how to obtain and apply licenses, see the Cisco NX-OS Licensing Guide.

https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/multicast/configuration/guide/b_Cisco_Nexus_9000_Series_NX-OS_Multicast_Routing_Configuration_Guide_7x/b_Cisco_Nexus_9000_Series_NX-OS_Multicast_Routing_Configuration_Guide_7x_chapter_0100.html#reference_1577C753E1C24CCC8AE12104FC84AC78 Or later version (maybe mainly based around NX-OS v9.x https://www.cisco.com/c/en/us/td/docs/switches/datacenter/sw/nx-os/licensing/guide/b_Cisco_NX-OS_Licensing_Guide/b_Cisco_NX-OS_Licensing_Guide_chapter_01.html

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 123 of 242

As can be seen from above table extract The ESSENTIALS “standard” license is sufficient for operation with NEXIS and MEDIACENTRAL.

Note: NXOS LICENSING WITHOUT PIM NEXUS 9000 When using the simple no ip igmp snooping command described in section B.20.2.2. NX-OS Essential is sufficient….. NX-OS Advantage (formerly called Enterprise) is not required.

Using the commands directly below that seem to give the best “short” output the following information was tabulated: show ip igmp snooping groups detail| no-more

show ip igmp snooping explicit-tracking | no-more MULTICAST ADDRESS KNOWN FUNCTION ASSUMED FUNCTION

224.0.1.84 JINI

224.0.1.85 JINI

225.1.1.1 FAST SERVE/ PIVOT

ADMIN - SCOPED ADMINISTRATIVELY SCOPED ADMINISTRATIVELY SCOPED

239.255.102.18 UNKNOWN UNKNOWN

239.255.255.250 Simple Service Discovery Protocol (SSDP)

And /or

multicast DNS (mDNS)

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 124 of 242

239.255.255.253 SLP, Service Location Protocol.

239.255.2.3 USED BY AVID MEDIA INDEXER NOMI

The IP addresses Associated with FastServe and Pivot were the only ones using 225.1.1.1 ping multicast 224.0.0.1 interface vl 164 count 1 ping multicast 239.255.2.3 interface vl 164 count 1 ping multicast 239.255.255.253 interface vl 164 count 1 - may not get any replies to this ping multicast 224.0.1.84 interface vl 164 count 1 ping multicast 224.0.1.85 interface vl 164 count 1 - may not get any replies to this ping multicast 239.255.102.18 interface vl 164 count 1 - may not get any replies to this B.20.2.2 – Field Knowledge NEXUS & Multicast PART 2 The ip igmp snooping querier method described above is IMHO rather cumbersome. A simple method is described below. Thanks to my friendly technical marketing engineer contact. This has yet to be field tested in an Avid solution at time of writing (JUL2020) By doing this: switch(config)# vlan configuration 5

switch(config-vlan-config)# no ip igmp snooping

You disable IGMP snooping on VLAN 5. Also if you chose range for VLAN configuration, this can be executed for multiple VLANs at the same time. This has to be done for all necessary VLANs in all NEXUS switches that use that VLAN

Note: This is the “simplest method” but may not be the “best method” where there is lots of multicast routing in progress …... in which case it is necessary to get “busy” with igmp snooping queriers as described in NETREQS appendix B20.2.1. Multicast is a “dark art” and I prefer simple solutions.

You can do this with NXOS, should be across the board from N3K to N9K and anything in between, by configuring IGMP snooping per VLAN, more info for N9K, but other should have same section: https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/93x/multicast/b-cisco-nexus-9000-series-nx-os-

multicast-routing-configuration-guide-93x/b-cisco-nexus-9000-series-nx-os-multicast-routing-configuration-guide-93x_chapter_0110.html#task_767AD7DE9F554649B7C7D5071521752B

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 125 of 242

This has been proven on a NEXUS 93000 (some older NXOS might supported it but it might be deprecated on newer versions, or vice versa). Some might consider this method to be a bit of a blunt instrument. I have published other methods in this section should more granularity/complexity be desired. But I do not consider this a dangerous option, as it is used only on specific VLAN, especially as other vendors’ products have IGMP disabled globally as default. If there is no multicast routing into this VLAN, and why on earth would there be in the Avid SERVER VLAN, then this is not an issue? The IGMP snooping RFC and subsequent implementations have a major flaw IMHO, they should have excluded 239.x.x.x link local addresses and allowed them to propagate as normal, they are generally small and insignificant. After all IGMP was brought in to dampen the burden of Multicast ROUTED packets, not L2 multicast. Maybe it would be nice if vendors enabled the exclusion of IP ranges from IGMP operations based on an access list, but I don’t not think they do. I am not a multicast guru and prefer simple solutions where possible. In this Section B.20 I have re-published some Cisco articles from Catalyst days…. But I have yet to find similar article for NEXUS. Using ip pim sparse-mode has licensing implications in NEXUS (which was not the case in Catalyst and may not be an issue for CBS), needing the enhanced Cisco licenses even though IGMP forwarding functionality is the tip of the iceberg and when we have used it…. Avid needs, with link local multicast use a side effect of pim sparse-mode not any multicast routing functionality. Of course TVSTATIONS makes a lot of use of multicast in in corporate LANs, to watch user selected channels via their workstations, so have lots of experience to bring to the table when it used for MROUTING, but as I stated above I would question why any such MROUTING would need to exist in the Avid VLANs, and if these production network switches are a shared environment with other equipment vendors where MROUTING does exists for other VLANs then this simple approach should be joined by a suitable ACL to prevent such packets entering the AVID VLANs.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 126 of 242

B.20.3 – UCS Blade Servers Multicast Propagation A similar challenge might exist with Cisco UCS (and maybe other vendors too). The Cisco Community article below has some helpful information, including a short PPTX on one of the posts. https://community.cisco.com/t5/unified-computing-system/multicast-on-ucs/td-p/1377577

B.20.4 Some other useful Multicast URL & Information https://www.cisco.com/c/en/us/td/docs/ios-xml/ios/ipmulti_pim/configuration/xe-3s/asr903/imc-pim-xe-3s-asr903-book/ip_multicast_technology_overview.pdf Limited Scope Addresses The range 239.0.0.0 to 239.255.255.255 is reserved as administratively or limited scoped addresses for use in private multicast domains. These addresses are constrained to a local group or organization. Companies, universities, and other organizations can use limited scope addresses to have local multicast applications that will not be forwarded outside their domain. Routers typically are configured with filters to prevent multicast traffic in this address range from flowing outside an autonomous system (AS) or any user-defined domain. Within an AS or domain, the limited scope address range can be further subdivided so that local multicast boundaries can be defined. RFC 2365—Administratively Scoped Addresses RFC 2365 provides limited guidelines on how the multicast address space can be divided and used privately by enterprises. The terminology “Administratively Scoped IPv4 multicast space” relates to the group address range of 239.0.0.0 to 239.255.255.255. The key properties of Administratively Scoped IP Multicast are that: • Packets addressed to Administratively Scoped multicast addresses do not cross configured administrative boundaries. The limits of these scope boundaries often are called “Zones” or “Scoped Zones.” • Administratively Scoped multicast addresses are locally assigned and are not required to be unique across administrative boundaries. Table 9 and the bullet items that follow it summarize the recommendations of RFC 2365. • Organization-Local Scope addresses are recommended for private use within an organization for intersite applications that will be run regionally or globally. • The address range numerically below the Organization-Local Scope is intended as the expansion space for the Organization-Local Scope. Organizations can allocate or subdivide this range as needed either to extend the Organization Local Scope or to create other geographically smaller subscopes within the Enterprise. • Site-Local Scope addresses represent the smallest possible scope in the network. More applications are being developed that default to using this scope (unless configured otherwise) to ensure that the scope of their application is limited to the smallest scope size. This is why it is important to adhere to RFC 2365 guidelines for the Site-Local Scope. Note: It is unfortunate that many applications do not behave in this manner and instead often default to using addresses in a global scope instead. This results in their application traffic being multicast far beyond where it is desired by the network administrator. • The address range numerically below the Site-Local Scope is intended as expansion space for the Site-Local Scope. Organizations can allocate these ranges for private use if they exceed the 239.255.0.0/16 Organization-Local range. Table 9 Administratively Scoped Addresses 239.0.0.0/8 Range Description Reference 239.000.000.000-239.191.255.255 Organization-Local Scope Expansion Space [Meyer, RFC 2365]

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 127 of 242

239.192.000.000-239.195.255.255 Organization-Local Scope [Meyer, RFC 2365] 239.195.000.000-239.254.255.255 Site-Local Scope Expansion Space [Meyer, RFC 2365] 239.255.000.000-239.255.255.255 Site-Local Scope [Meyer, RFC 2365] https://www.cisco.com/c/dam/en/us/support/docs/ip/ip-multicast/ipmlt_wp.pdf https://www.tldp.org/HOWTO/Multicast-HOWTO-2.html TTL. The TTL (Time To Live) field in the IP header has a double significance in multicast. As always, it controls the live time of the datagram to avoid it being looped forever due to routing errors. Routers decrement the TTL of every datagram as it traverses from one network to another and when its value reaches 0 the packet is dropped. The TTL in IPv4 multicasting has also the meaning of "threshold". Its use becomes evident with an example: suppose you set a long, bandwidth consuming, video conference between all the hosts belonging to your department. You want that huge amount of traffic to remain in your LAN. Perhaps your department is big enough to have various LANs. In that case you want those hosts belonging to each of your LANs to attend the conference, but in any case, you want to collapse the entire Internet with your multicast traffic. There is a need to limit how "long" multicast traffic will expand across routers. That's what the TTL is used for. Routers have a TTL threshold assigned to each of its interfaces, and only datagrams with a TTL greater than the interface's threshold are forwarded. Note that when a datagram traverses a router with a certain threshold assigned, the datagram's TTL is not decremented by the value of the threshold. Only a comparison is made. (As before, the TTL is decremented by 1 each time a datagram passes across a router). A list of TTL thresholds and their associated scope follows: TTL Scope ---------------------------------------------------------------------- 0 Restricted to the same host. Won't be output by any interface. 1 Restricted to the same subnet. Won't be forwarded by a router. <32 Restricted to the same site, organization or department. <64 Restricted to the same region. <128 Restricted to the same continent. <255 Unrestricted in scope. Global. Nobody knows what "site" or "region" mean exactly. It is up to the administrators to decide what these limits apply to. The TTL-trick is not always flexible enough for all needs, especially when dealing with overlapping regions or trying to establish geographic, topologic and bandwidth limits simultaneously. To solve this problems, administratively scoped IPv4 multicast regions were established in 1994. (see D. Meyer's "Administratively Scoped IP Multicast" Internet draft). It does scoping based on multicast addresses rather than on TTLs. The range 239.0.0.0 to 239.255.255.255 is reserved for this administrative scoping.

Also consider that some of the reading on VXLAN suggests that 239.x.y.x addresses are also used for propagation of BUM traffic between VTEPs, and NOMI uses.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 128 of 242

Configure VXLAN Flood and Learn with Multicast Core https://www.cisco.com/c/en/us/support/docs/ios-nx-os-software/nx-os-software/200262-Configure-VxLAN-Flood-And-Learn-Using-Mu.html VXLAN Series – Multicast usage in VXLAN – Part 3 https://blogs.vmware.com/vsphere/2013/05/vxlan-series-multicast-usage-in-vxlan-part-3.html • Section 21.2.3: Multicast and Broadcast over VXLAN https://www.arista.com/assets/data/pdf/user-manual/um-eos/Chapters/VXLAN.pdf

B.20.5 Some good tutorials on IGMP SNOOPING This first one was very helpful, but the second & third are also worthwhile Tall Paul TECH AUG 2020 IGMP - Internet Group Management Protocol https://www.youtube.com/watch?v=MaTkt-wNHRg https://www.youtube.com/watch?v=98PrUvedqI4 Keith Barker IGMP Snooping and VLC player JUL 2021 https://www.youtube.com/watch?v=5Ovh9dUsAWU And this one puts a different spin on Multicast which is VERY HELPFUL too Multicast Explained in 5 Minutes | CCIE Journey for Week 6-12-2020 https://www.youtube.com/watch?v=W5oMvrMRM3Q This series by Nic Bhasin is VERY GOOD Lecture 1 - IP Multicast Basics and Addressing 20 Sept 2016 https://www.youtube.com/watch?v=fRiOOWJDcK8 Lecture 2 - IP Multicast Routers and Routing Protocols 17 Sept 2016 https://www.youtube.com/watch?v=Wao6FHI8rgE Lecture 3 - IP Multicast Receiver Signaling with IGMPv1 and IGMPv2 20 Sept 2016 https://www.youtube.com/watch?v=BC8MfzMSRhY

Demo 1.1 - IGMPv2 on IOS Routers 24 Sept 2016 https://www.youtube.com/watch?v=-YR3PqRqDak

Lecture 4 - IP Multicast Receiver Signaling with IGMPv3

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 129 of 242

23 Sept 2016 https://www.youtube.com/watch?v=Sgppv6HRFSs Lecture 5 - IP Multicast Source Signaling 28 Sept 2016 https://www.youtube.com/watch?v=HZdXpyMbq20 Lecture 6 - Introduction to PIM, PIM Dense Mode Deep Dive 28 Sept 2016 https://www.youtube.com/watch?v=9sNOiLjyPnk Lecture 7 - Introduction to PIM Sparse Mode 6 Oct 2016 https://www.youtube.com/watch?v=QaNFiRJiTNM Lecture 8 - Advanced PIM Sparse Mode Deep Dive Part 1 24 Oct 2016 https://www.youtube.com/watch?v=WQvbTxDmXMc Lecture 9 - Advanced PIM Sparse Mode Deep Dive Part 2 25 Oct 2016 https://www.youtube.com/watch?v=bMVbDiwN7UY Lecture 10 - Advanced PIM Sparse Mode Deep Dive Part 3 27 Oct 2016 https://www.youtube.com/watch?v=SCVDPlmsl4g IGMP SNOOPING – WHICH URL?? Cisco Multicast Routing for CCNA, CCNP, and CCIE Candidates 19 Apr 2016 https://www.youtube.com/watch?v=Gjt2L9jAYNA IGMP SNOOPING cisco multicast igmp snooping without router solutions 1080p Feb 2020 https://www.youtube.com/watch?v=tHiBcOxrUTo

B.20.6 Wireshark examples on IGMP SNOOPING https://en.wikipedia.org/wiki/Multicast_address

IP multicast address

Description Routable

224.0.0.0 Base address (reserved) No

224.0.0.1 The ALL HOSTS multicast group addresses all hosts on the same network segment.

No

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 130 of 242

224.0.0.2 The ALL ROUTERS multicast group addresses all routers on the same network segment.

NO

Screen shots taken from the URL on B.20.5 Tall Paul TECH AUG 2020 IGMP - Internet Group Management Protocol https://www.youtube.com/watch?v=MaTkt-wNHRg Below is a multicast LEAVE group message from device 192.168.0.10 to 224.0.0.2 ALL ROUTERS) to leave multicast stream 239.1.1.101

Note that this leave message is sent to ALL ROUTERS multicast group addresses

The “JOIN” or “membership report group” message is sent from 192.168.0.10 to the Multicast IP address 239.1.1.101

The QUERY message is sent from (SVI of switch – which may not be the DFGW) 192.168.0.250 to 224.0.01 ALL HOSTS. This is a GENERAL message (v1/v2) rthare than a group specific message (v2 and beyond)

The response to the QUERY message is a repeat the “JOIN” or “membership report group” message is sent from 192.168.0.10 to the Multicast IP address 239.1.1.101, to “indicate” ongoing desire for devices via that port (as it maybe downlinked to another switch or WiFi AP)

B.21 LoopGuard and FHRP The use of Loop Guard and a first Hop Redundancy protocol has proven to be unsuitable for use with ISIS 7000 deployments. The URL below provide a detailed review of this feature and the reader should quickly establish that it will cause err-disable port shutdowns on the Cisco switches. http://www.cisco.com/en/US/tech/tk389/tk621/technologies_tech_note09186a0080094640.shtml The STP loop guard feature provides additional protection against Layer 2 forwarding loops (STP loops). An STP loop is created when an STP blocking port in a redundant topology erroneously transitions to the forwarding state. This usually happens because one of the ports of a physically redundant topology (not necessarily the STP blocking port) no longer receives STP BPDUs. In its operation, STP relies on continuous reception or transmission of BPDUs based on the port role. The designated port transmits BPDUs, and the non-designated port receives BPDUs.

B.22 Speed setting on Switch ports Avid documentation does not mandate the setting of fixed speeds on NICs and Ethernet switch ports. There are many differing opinions within Avid. Generally, for all modern environments the

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 131 of 242

settings on both the NIC and the Switch should be 'auto'. Only in the rare instances where 'auto' doesn't produce the desired result should it be changed and then, the change needs to be made on the NIC and the Switch. Speed and Duplex are negotiated during the first few milliseconds of communication between NIC and Switch. Once negotiated, it won't change. So, if 'auto' negotiates to 1000 Mbps Full Duplex, as it almost always does, then manually setting the NIC and Switch to 1000 Full will not get you better performance - and you will have to remember to re-configure the NIC and Switch Port if you want to use it for something else. All situations have different variables. Also considered that devices that are turned off will report a lower speed, when connected but "dormant" and physically powered. This is one reason why interface descriptions are a MASSIVE help when diagnosing problems, this combined with commands like show interfaces status (Cisco). Yes, it takes time, but interface descriptions and good documentation are like a pension payment, and investment in the future that WILL pay back. If SNMP and/or a simple logging is correctly configured, that will show such things as speed changes, but you do not want to configure logging on devices that are regularly disconnected or powered off because that just generate "noise", I.E. useless event data. Should an operator go the effort of manually setting the speed/duplex on a troublesome connection, this generally does not fix the cause, but overcomes the symptom. Frequently such incorrect speed issues are usually a sign of a cabling defect. One European (Q4 2017) customer reported SEMAPHORE Errors with ISIS 7x00 clients and connecting via a FEX 2248TPE. There were multiple FEXs all with same configuration, but one FEX had clients that showed intermittent SEMAPHORE errors, there was no pattern to the occurrence of errors. As a diagnostic step the customer set some clients to a fixed connection of speed 1000 full duplex and left others to use auto-negotiation. The clients that were fixed to1000 FDX no longer exhibited the error. The theory here is that while all the FEX ports showed operation at Gigabit speed, that a possible cabling or NIC issue was causing intermittent renegotiation to 100 Mbps operation, and then flipping back 1000 Mbps operation, this would not cause link status events to be reported but it would upset the NLE operation. The interface commands below will assist. If having intermittent disconnect problems perhaps select some ports to monitor logging status to see if NEXIS disconnect events coincide with port status changes (of course need to record timing a look for a match. >>> logging event port link-status Also we should change some (different) ports to be fixed speed and full duplex to see if that >>> speed {10 | 100 | 1000 | auto} >>> duplex {auto | full | half} Of course, this needs reliable interface port descriptions to be added too.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 132 of 242

Here are three “port flap sequence” from one customer log extracts, on three different ports, that cause clients to disconnect at layer2/1, and hence causing the NEXIS clients software on the workstation to disconnect from the storage interrupting the workflow on the NLE. 2019 Mar 27 11:50:47.632 TVS-EDITOR-N9K %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet1/32 is down (Link failure) 2019 Mar 27 11:51:02.880 TVS-EDITOR-N9K %ETHPORT-5-SPEED: Interface Ethernet1/32, operational speed changed to 1 Gbps 2019 Mar 27 11:51:02.880 TVS-EDITOR-N9K %ETHPORT-5-IF_DUPLEX: Interface Ethernet1/32, operational duplex mode changed to Full 2019 Mar 27 11:51:02.880 TVS-EDITOR-N9K %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet1/32, operational Receive Flow Control state changed to on 2019 Mar 27 11:51:02.880 TVS-EDITOR-N9K %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet1/32, operational Transmit Flow Control state changed to off 2019 Mar 27 11:51:03.006 TVS-EDITOR-N9K %ETHPORT-5-IF_UP: Interface Ethernet1/32 is up in mode access 2019 Mar 27 11:51:11.602 TVS-EDITOR-N9K %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet1/32 is down (Link failure) 2019 Mar 27 11:51:15.782 TVS-EDITOR-N9K %ETHPORT-5-SPEED: Interface Ethernet1/32, operational speed changed to 1 Gbps 2019 Mar 27 11:51:15.782 TVS-EDITOR-N9K %ETHPORT-5-IF_DUPLEX: Interface Ethernet1/32, operational duplex mode changed to Full 2019 Mar 27 11:51:15.782 TVS-EDITOR-N9K %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet1/32, operational Receive Flow Control state changed to on 2019 Mar 27 11:51:15.782 TVS-EDITOR-N9K %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet1/32, operational Transmit Flow Control state changed to off 2019 Mar 27 11:51:15.793 TVS-EDITOR-N9K %ETHPORT-5-IF_UP: Interface Ethernet1/32 is up in mode access And 2019 Mar 27 12:23:27.063 TVS-EDITOR-N9K %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface

Ethernet1/36 is down (Link failure) 2019 Mar 27 12:23:31.325 TVS-EDITOR-N9K %ETHPORT-5-SPEED: Interface Ethernet1/36, operational speed changed to 1 Gbps 2019 Mar 27 12:23:31.325 TVS-EDITOR-N9K %ETHPORT-5-IF_DUPLEX: Interface Ethernet1/36, operational duplex mode changed to Full 2019 Mar 27 12:23:31.325 TVS-EDITOR-N9K %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet1/36, operational Receive Flow Control state changed to on 2019 Mar 27 12:23:31.325 TVS-EDITOR-N9K %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet1/36, operational Transmit Flow Control state changed to off 2019 Mar 27 12:23:31.336 TVS-EDITOR-N9K %ETHPORT-5-IF_UP: Interface Ethernet1/36 is up in mode access 2019 Mar 27 12:23:49.321 TVS-EDITOR-N9K %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet1/36 is down (Link failure) 2019 Mar 27 12:23:53.832 TVS-EDITOR-N9K %ETHPORT-5-SPEED: Interface Ethernet1/36, operational speed changed to 1 Gbps 2019 Mar 27 12:23:53.832 TVS-EDITOR-N9K %ETHPORT-5-IF_DUPLEX: Interface Ethernet1/36, operational duplex mode changed to Full 2019 Mar 27 12:23:53.832 TVS-EDITOR-N9K %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet1/36, operational Receive Flow Control state changed to on 2019 Mar 27 12:23:53.832 TVS-EDITOR-N9K %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet1/36, operational Transmit Flow Control state changed to off 2019 Mar 27 12:23:53.842 TVS-EDITOR-N9K %ETHPORT-5-IF_UP: Interface Ethernet1/36 is up in mode access And 2019 Mar 27 13:33:36.510 TVS-EDITOR-N9K %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet1/37 is down (Link failure) 2019 Mar 27 13:33:40.197 TVS-EDITOR-N9K %ETHPORT-5-SPEED: Interface Ethernet1/37, operational speed changed to 1 Gbps 2019 Mar 27 13:33:40.197 TVS-EDITOR-N9K %ETHPORT-5-IF_DUPLEX: Interface Ethernet1/37, operational duplex mode changed to Full 2019 Mar 27 13:33:40.197 TVS-EDITOR-N9K %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet1/37, operational Receive Flow Control state changed to on 2019 Mar 27 13:33:40.197 TVS-EDITOR-N9K %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet1/37, operational Transmit Flow Control state changed to off 2019 Mar 27 13:33:40.211 TVS-EDITOR-N9K %ETHPORT-5-IF_UP: Interface Ethernet1/37 is up in mode access

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 133 of 242

2019 Mar 27 13:34:37.471 TVS-EDITOR-N9K %ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface Ethernet1/37 is down (Link failure) 2019 Mar 27 13:34:41.754 TVS-EDITOR-N9K %ETHPORT-5-SPEED: Interface Ethernet1/37, operational speed changed to 1 Gbps 2019 Mar 27 13:34:41.754 TVS-EDITOR-N9K %ETHPORT-5-IF_DUPLEX: Interface Ethernet1/37, operational duplex mode changed to Full 2019 Mar 27 13:34:41.754 TVS-EDITOR-N9K %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet1/37, operational Receive Flow Control state changed to on 2019 Mar 27 13:34:41.754 TVS-EDITOR-N9K %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet1/37, operational Transmit Flow Control state changed to off 2019 Mar 27 13:34:42.160 TVS-EDITOR-N9K %ETHPORT-5-IF_UP: Interface Ethernet1/37 is up in mode access My Vanilla Configs always use the minimum required setting to create expected normal operation and hence additional polices may be applied, based on each site methods and specific requirements. However, one might conclude that 1G clients must always work at 1G, so why not disable auto-negotiation it offers no benefit. Under normal circumstances setting a fixed speed will not be harmful, setting the duplex is “belt and braces” because 1G and above should only function in Full Duplex mode anyway. The same applies to 10G and 40G devices. But really the end device should negotiate the highest speed available, the fact that this is showing disconnects/reconnects is suggesting other issues might be the root cause, and that setting fixed speed/duplex might overcome the issue while masking root cause. interface Ethernet1/32 description MEDIA COMPOSER NLE HP workstation Z840 switchport switchport access vlan 20

speed 1000 duplex full spanning-tree port type edge no shutdown

B.23 Duplicate IP Address Error Message Troubleshoot – Later Cisco IOS The referenced URL below explains a bug between the way Windows later than Vista execute their duplicate IP check and how the Cisco switches react to that ARP. Later s/w versions of C4500-X and C4948E/C4900M can exhibit the bug, and ISIS 5x00 systems have been known to fall victim The command below, added to cisco ports connecting to ISIS engines to control "ip device tracking" feature of later Cisco IOS, can be used to address this problem. ip device tracking maximum 0

http://www.cisco.com/image/gif/paws/116529/116529-problemsolution-product-00.pdf https://supportforums.cisco.com/discussion/12172096/duplicate-ip-0000-conflict-8021x-windows-7-clients http://communities.labminutes.com/routing-and-switching/device-tracking-issue-on-catalyst-switches-15-2(1)e/ Alternative IOS command discussed in the article are ip device tracking probe delay 10

or ip device tracking probe use−svi

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 134 of 242

Also from VMWARE KB: False duplicate IP address detected on Microsoft Windows Vista and later virtual machines on ESX/ESXi when using Cisco devices on the environment (1028373) https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=1028373 Symptoms

When you assign an IP address on Windows Vista and later versions, you see a duplicate IP address conflict.

When you restart Windows Vista and later versions, you receive a 169.254.x.x IP.

When you set up the same virtual machine on a vSwitch with no uplink port on the vSwitch, the IP address is assigned successfully.

When you assign the same IP address to a Windows 2003 virtual machine on the same vSwitch, the IP address is assigned successfully.

Cause This issue occurs when the Cisco switch has gratuitous ARPs enabled or the ArpProxySvc replied to all ARP requests incorrectly.

B.24 Using WINMERGE to compare config files (FIELD-TIP) WINMERGE is an open source solution for Windows (NOT FOR MAC unless in a VM! ) that will compare two (text) files and highlight all the changes on common lines which need not be the SAME line number in the files WinMerge (http://winmerge.org) is an open source and free differencing and merging tool for Windows. It allows you to open two text files (in our case switch config files) in a split screen, the two files are automatically aligned and all the different lines are highlighted. Furthermore, the specific differences are additionally highlighted within that line. It is a very effective tool to compare the configuration files of redundant switches to make sure there are no unintentional differences and it helps you spot configuration mistakes. A second usage case is to compare the before- and after- configurations to verify what was really changed. Example: comparison of two core switches where the automatic highlighting helped us identify a miyconfigured HSRP interface – a crucial line has been omitted on Core 1!

B.25 Serial connection alternatives to DB9 using USB (FIELD-TIP) Many PCs no longer have a 9 pin D-TYPE, and if you have a MAC you are also out of luck form “REAL” serial connection. For serial connectivity I use STARTEC adapter. This works on Windows 7 x64 using since 2010),and Windows XP32 (using since 2008). I have also made it work on a MAC in conjunction with iTERM2, and in a Windows VM so I can use Putty. I have been doing this on a MAC too since 2014.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 135 of 242

USB to RS-232 Serial DB9 Adapter http://us.startech.com/product/ICUSB232-USB-to-RS232-DB9-Serial-Adapter-Cable-Male-to-Male-Serial-Adapter-USB-to-Serial This I use in combination with a Cisco rolled cable for my connectivity, or via various other adapters and flat cable for some of the NON-CISCO vendors who have different presentation. In 2016 I was advised about a combined cable which integrates the USB-Serial adapters and works with. When us techy-types congregate, we always have to swap tips! On Amazon.com search for Ftdi USB to Serial / Rs232 Console Rollover Cable for Cisco Routers - RJ45 Price - USD12.90 On Amazon.co.uk search for Asunflower® Cisco USB Console Cable FTDI USB to RJ45 for Windows Vista MAC Linux RS-232 Price GBP 11.99

NOTE USB -C versions also available

Works great on MAC and PC.

B25.1. Use the management network on NEXUS switches & remote connection While on Catalyst switches using the management interface ports was and extremely painful process, on NEXUS switches it is a breeze. When setting up a common network deployments style such as two Core and two Edge devices, having two USB sunflower cables and a cheap 8 port unmanaged network switch, and 5 Ethernet patch cords costing less than 50 EUR/GBP/USD, will save a massive amount of time and will repay it outlay several times over. After doing basic setup via slow console cables, you can telnet/ssh to all switches at the same time. Such improved speed and flexibility this could save a day (or more) in config and diagnostics. It is worth buying for EVERY project even if it is never used again, but more environmentally sustainable if moved from site to site. Amazon next day delivery (or local equivalent) is your friend. Have this in your toolbox for site. This is even MORE important for doing this with the restriction that are placed upon us in during the Covid 19 Pandemic where a lot more has to be done remotely.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 136 of 242

Although this diagram shows VNC, RDP is just fine too, probably better in an all Windows environment. With a 1U server and eight LAN ports, the config JUMP workstation and all the Dumb hosts can exist in one physical device. The serial ports in the Windows JUM device appear and COM6, COM 7, COM 8, COM9. At the site in Mainland Europe where the above diagram is taken from, we are using the open source OPENVPN (https://openvpn.net/) solution, which can be deployed as a virtual appliance in the SAME host server and the first two connections are no recurring cost. And I will be doing something similar for a project in USA next month. All from the comfort of my Desk in UK. This probably works fine for other switch vendors too. Considering most recent 1U servers come with 4 x 1G, adding another 4 ports card is not expensive and any cheap NIC will do for the task of a DUMB PING host. Again, on Amazon I have seen then for less than 50 EUR/GBP/USD, but certainly less than 100 EUR/GBP/USD.

B.26 Ethernet connection alternatives using USB (FIELD-TIP) Messing about with your primary Ethernet connection while on site always has “hidden teeth” when retuning to the office and you cannot connect, because you changed the parameters. If all you need on site is a basic connection for telnet and TFTP into switches than a simple USB 2.0 LAN Adapter to Ethernet RJ45 Network Cable 10/100Mbps Mac Windows 7/8 will cost a less than $10. Mine came from Ebay, and works just fine, normally I use it in the Windows VM, but often the windows VM must have a ROUTE ADD statement at CLI/COMMAND Window (must be RUN AS ADMIN) to direct packets to the test networks (or VLANS being configured) instead of the primary bound path of the VM to the “outside world”.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 137 of 242

B.27 Ping testing Cisco links (FIELD-TIP) When ping testing to validate a path, always use something like Ping X.X.X.X repeat 10000 You can have 5 out 5 good replies multiple times in a row, but when you send 10,000 pings and only get 9946 replies – it means something fishy is going on, that 0.5% failure rate should not be there. It takes only a couple of minutes to finish if all goes well. Note that this is about pink testing at the CLI between directly connected Cisco devices, and not at the windows CLI which would take an epoch!

B.28 Service Timestamps and Time setting in F10 S4810 & S60 To correctly view logs it is important that the correct time exists and that the switch is configured to timestamp the logs otherwise you get a used log entry such as the one below. 25w3d4h: %STKUNIT0-M:CP %IFMGR-5-OSTATE_DN: Changed interface state to down: Gi 1/6 25w3d4h: %STKUNIT0-M:CP %IFMGR-5-OSTATE_UP: Changed interface state to up: Gi 1/6

This config example was extracted from a running S4810 and the S60 was identical/

service timestamps log datetime localtime show-timezone service timestamps debug datetime localtime show-timezone ntp server 10.10.10.41 <<<< CHANGE IP ADDRESS AS APPROPRIATE clock timezone EST -5 clock summer-time EDT recurring 2 Sun Mar 02:00 1 sun Nov 02:00

Note this example is for USA but give then flavor of how to do this for any time Zone

B.29 Service Timestamps and Time setting in Dell N3024/48 To correctly view logs it is important that the correct time exists and that the switch is configured to timestamp the logs otherwise you get a used log entry such as the one below. In the Dell N3024/3048 logs are automatically time stamped, there is no service timestamps command to be manipulated but the syntax of the summer-time command is different, as the is NTP setting.

sntp server 10.10.10.41 sntp unicast client enable clock timezone -5 minutes 0 zone TEST clock summer-time recurring EU|USA offset 60 ZONE EDT or clock summer-time recurring first sun mar 02:00 last sun oct 03:00 offset 60 ZONE ABC

Note that the week parameter can be first and last or 1-5

Note that SNTP needs a second command sntp unicast client enable otherwise it will not pickup the time.

This is a config example from a running switch.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 138 of 242

sntp unicast client enable

sntp server 10.229.252.150

clock summer-time recurring EU zone "CEST"

clock timezone 1 minutes 0 zone "CET"

THIS URL is a good primer: https://timetoolsltd.com/network-time-servers/the-difference-between-ntp-and-sntp/ The CLI output below shows that the ntp server and ntp status and that time source is SNTP.

KLAB_ACCESS03#show clock

11:33:46 CET(UTC+1:00) Jan 21 2019

Time source is SNTP

KLAB_ACCESS03#show sntp status

Client Mode: Unicast

Last Update Time: Jan 21 09:11:09 2019

Unicast servers:

Server Status Last response

--------------- ---------------------- --------------------------

10.229.252.150 Success 09:11:09 Jan 21 2019

KLAB_ACCESS03#show sntp server

Server Host Address: 10.229.252.150

Server Type: IPv4

Server Stratum: 2

Server Reference Id: NTP Bits: 0x7fc04431

Server Mode: Server

Server Maximum Entries: 8

Server Current Entries: 1

SNTP Servers

------------

Host Address: 10.229.252.150

Address Type: IPv4

Priority: 1

Version: 4

Port: 123

Last Update Time: Jan 21 09:11:09 2019

Last Attempt Time: Jan 21 10:33:21 2019

Last Update Status: Success

Total Unicast Requests: 5041

Failed Unicast Requests: 0

KLAB_ACCESS03#

B.30 Service Timestamps and Time setting in DELL S4048 To correctly view logs, it is important that the correct time exists and that the switch is configured to timestamp the logs otherwise you get a used log entry such as the one below. AFTER Jul 11 09:50:19 UTC: %STKUNIT1-M:CP %SEC-3-AUTHENTICATION_ENABLE_SUCCESS: Enable authentication success on vty0 ( 10.134.133.221 ) for user avid Jul 11 09:50:14 UTC: %STKUNIT1-M:CP %SEC-5-LOGIN_SUCCESS: Login successful for user avid on line vty0 ( 10.134.133.221 ) Jul 11 09:50:07 UTC: %STKUNIT1-M:CP %SEC-5-LOGOUT: Exec session is terminated for user avid on line vty0 ( 10.134.133.221 )

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 139 of 242

Jul 11 09:49:27 UTC: %STKUNIT1-M:CP %SYS-5-CONFIG_I: Configured from vty0 ( 10.134.133.221 )by avid

BEFORE 2w5d13h: %STKUNIT1-M:CP %SEC-3-AUTHENTICATION_ENABLE_SUCCESS: Enable authentication success on vty0 ( 10.134.133.221 ) for user avid 2w5d13h: %STKUNIT1-M:CP %SEC-5-LOGIN_SUCCESS: Login successful for user avid on line vty0 ( 10.134.133.221 ) 2w5d13h: %STKUNIT1-M:CP %SEC-5-LOGOUT: Exec session is terminated for user avid on line vty0 ( 10.134.133.221 ) 2w5d13h: %STKUNIT1-M:CP %SEC-3-AUTHENTICATION_ENABLE_SUCCESS: Enable authentication success on vty0 ( 10.134.133.221 ) for user avid 2w5d13h: %STKUNIT1-M:CP %SEC-5-LOGIN_SUCCESS: Login successful for user avid on line vty0 ( 10.134.133.221 )

This config example was extracted from a running S4810 and the S60 was identical/

service timestamps log datetime localtime show-timezone service timestamps debug datetime localtime show-timezone ntp server 10.10.10.41 <<<< CHANGE IP ADDRESS AS APPROPRIATE clock timezone EST -5 0 clock summer-time EDT recurring 2 Sun Mar 02:00 1 sun Nov 02:00

Note this example is for USA but give then flavor of how to do this for any time Zone FROM A S4048 IN JAN 2019

clock timezone CET 1 0 clock summer-time CEST recurring last Sun Mar 2:00 last Sun Oct 2:00 service timestamps log datetime localtime show-timezone service timestamps debug datetime localtime show-timezone

Note: that the Dell S4048 logs are listed with newest first (unlike Cisco) the command below will list them in natural order and also no ask for you to press the space bar after each page S4048#show logging reverse | no-more

The CLI output below shows that the ntp server status and associations KLAB_VLTCORE1#sh ntp status

Clock is synchronized, stratum 3, reference is 10.229.252.150, vrf-id is 0

frequency is -20.796 ppm, stability is 0.066 ppm, precision is -19

reference time dff01867.51c59290 Mon, Jan 21 2019 10:07:35.319 UTC

clock offset is -1.265075 msec, root delay is 10.630 msec

root dispersion is 54.397 msec, peer dispersion is 15.435 sec

peer mode is client

KLAB_VLTCORE1#

KLAB_VLTCORE1#sh ntp associations

remote vrf-Id ref clock st when poll reach delay

offset disp

===========================================================================

=========

169.254.1.13 0 0.0.0.0 16 - 1024 0 0.00000

0.00000 0.00000

*10.229.252.150 0 216.239.35.0 2 940 1024 377 0.34600 -

1.2650 0.61500

* master (synced), # backup, + selected, - outlier, x falseticker

KLAB_VLTCORE1#

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 140 of 242

B.31 How to find IP address of a MAC address First this command TVS_SWC002_5672-2_CORE(config-if)# sh mac add int e1/5

Legend: * - primary entry, G - Gateway MAC, (R) - Routed MAC, O - Overlay MAC age - seconds since last seen,+ - primary entry using vPC Peer-Link VLAN MAC Address Type age Secure NTFY Ports/SWID.SSID.LID ---------+-----------------+--------+---------+------+----+------------------ * 1241 0060.dd43.2bd8 dynamic 0 F F Eth1/5

Then this command MIBCTSWC002_5672-2_CORE(config-if)# sh ip arp | inc 0060.dd43.2bd8 10.64.124.35 00:01:35 0060.dd43.2bd8 Vlan1241 TVS_SWC002_5672-2_CORE(config-if)#

And voila! The device of port e1/5 has a mac address of 0060.dd43.2bd8 and an IP address of 10.64.124.35

Note: This only works on the same switch. MAC Addresses on a subordinate L2 switch cannot be found this way

There Managed Switch Port Mapping Tool is available from https://www.switchportmapper.com/ An open source variant for Windows, called Switch Miner which appears to do much the same job is available from https://sourceforge.net/projects/switchminer/ It is a little buggy but does the job, and is fine for occasional use. It work well on Cisco Catalyst (not been able to try NEXUS at the time of writing FEB 2019) devices, that is designed for, less good on other vendors DELL/F10 as is to be expected .

B.32 Minimum Length of A Network Cable? From a networking perspective I would always suggest minimum of 2m….. While I have heard of this many times as best practice, I have looked before and found no confirmed reference. I recall it from optical connections, but this could be networking folklore as one can buy shorter cat 5/6 patch cables from reputable suppliers. A Google search "minimum length network cable” and found these two articles https://networkengineering.stackexchange.com/questions/7483/minimum-ethernet-cable-length

There is no minimum cable length when talking about standard copper-cables. When it comes to fiber, there is a minimum length depending on technology, diodes and so on. note, fibre minimums are a function of power. longer reach (i.e. higher power) expects higher attenuation; at short lengths the signal can blind (and even damage) the receiver. –

http://boards.straightdope.com/sdmb/showthread.php?t=599432

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 141 of 242

I did check 802.3, to find that the 2.5m minimum length applies to CSMA/CD networks, per IEEE 802.3, where overly short cables can cause the collision detection to malfunction. This might apply to half-duplex gigabit lines as well. It should not apply to switch-based networks which won't have physical layer collisions.

So, there is both confirmation and a little contradiction.

B.33 Cisco Nexus vPC Best Practices When setting up vPC pairs with Cisco Nexus it is important to have a vPC keep alive link in additional to a vPC peer link. This is explained in the URL below. This can be done on the management ports or via a front panel port, when an aggregate link can be used for “double protection”. Cisco Nexus 9000 Series NX-OS Interfaces Configuration Guide, Release 9.3(x) Chapter: Configuring vPCs https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/93x/interfaces/configuration/guide/b-cisco-nexus-9000-nx-os-interfaces-configuration-guide-93x/b-cisco-nexus-9000-nx-os-interfaces-configuration-guide-93x_chapter_01000.html Configuring vPCs NEXUS 9000 https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/6-x/interfaces/configuration/guide/b_Cisco_Nexus_9000_Series_NX-OS_Interfaces_Configuration_Guide/configuring_vpcs.pdf Design and Configuration Guide: Best Practices for Virtual Port Channels (vPC) on Cisco Nexus 7000 Series Switches Revised: June 2016 https://www.cisco.com/c/dam/en/us/td/docs/switches/datacenter/sw/design/vpc_design/vpc_best_practices_design_guide.pdf Data Center SwitchesCisco Nexus 5000 Series Switches White Papers Virtual PortChannel Quick Configuration Guide https://www.cisco.com/c/en/us/products/collateral/switches/nexus-5000-series-switches/configuration_guide_c07-543563.html An example is given below from Nexis 7000 Main switch N7k

interface port-channel77

description VPC-PEER-LINK

switchport

switchport mode trunk

spanning-tree port type network

no lacp suspend-individual

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 142 of 242

vpc peer-link

feature vpc

vpc domain 77

peer-switch

role priority 4096

system-priority 4096

peer-keepalive destination 10.10.10.2 source 10.10.10.1

delay restore 150

peer-gateway

interface mgmt0

vrf member management

ip address 10.10.10.1/30

Secondary switch N7k

interface port-channel77

description VPC PEER-LINK

switchport

switchport mode trunk

spanning-tree port type network

no lacp suspend-individual

vpc peer-link

feature vpc

vpc domain 77

peer-switch

role priority 8192

system-priority 4096

peer-keepalive destination 10.10.10.1 source 10.10.10.2

delay restore 150

peer-gateway

interface mgmt0

vrf member management

ip address 10.10.10.2/30

The vPC peer keepalive must be present for successful vPC pairing. The loss of a vPC peer keepalive path on a running switch while the vPC peer link is active will not break the pairing, but if the vPC peer link fails while there is no active vPC peer keepalive path, unexpected operation can occur, hence additional resilience in the vPC peer keepalive but using Port channel with two members and a dedicate VRF context is desirable. On a Nexus 93180YC the most cost-effective option is to use 10G TWINAX on while on a Nexus 9336C either two 100G have to be “sacrificed” with 40G TWINAX or optical BREAKOUT is used possible on two different ports s 6 more 10G ports main available. Do not use QSA and optics as this is more expensive and inefficient than TWINAX.

B.33.1 PATH diversity NEXUS 93000 series switches In a 1U device there is limited HW diversity that can be achieved as there are no I/O cards, but often there is different slice or PHY segments hence it can often be advised to deploy VPC peer links and vPC peer keepalive paths at opposite end of the switch. Some devices have no slice diversity as shown below

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 143 of 242

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 144 of 242

B.34 Cisco Nexus 93000 series Port Breakout & QSA This section is primary describing differing option for port breakout on Nexus 93000/9300 series of switches. These principles apply equally to other vendors network switch products but the syntax necessary to achieve it may differ.

B.34.1 For Nexus 93180LC-EX The use for ports on the Cisco Nexus 93180 LC for port speed less than 40/25G has limitations based the s/w version and the articles below explain some of the intricacies. Cisco Nexus 93180LC-EX NX-OS Mode Hardware Installation Guide | Managing the Switch | Configuring Ports https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/hw/n93180lcex_hig/guide/b_c93180lcex_nxos_mode_hardware_install_guide/b_c93180lcex_nxos_mode_hardware_install_guide_chapter_01011.html

Configuring Ports

This switch has 32 ports of which 28 are configured as 40/50-Gigabit ports and 4 are configured as

40/100-Gigabit ports. You can change the ways that these ports are used by using templates to

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 145 of 242

configure all the ports in commonly used ways or by configuring ports individually. Three of the

templates that you can use are the following:

28 40/50-Gigabit ports and 4 40/100-Gigabit ports (default configuration)

24 40/50-Gigabit ports and 6 40/100-Gigabit ports

18 40/100-Gigabit ports

You can individually configure the ports 1 to 28 as indicated in the following table:

Odd Numbered Port (1 to

27)

Even Numbered Port (2 to 28) below the Odd Numbered

Port

40-Gigabit QSFP+ port

(default)

40-Gigabit QSFP+ port (default)

40-Gigabit port with 4x10- Hardware disabled

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 146 of 242

Odd Numbered Port (1 to

27)

Even Numbered Port (2 to 28) below the Odd Numbered

Port

Gigabit breakout feature

100-Gigabit QSFP28 port Hardware disabled

100-Gigabit port with 4x25-

Gigabit breakout feature

Hardware disabled

1/10-Gigabit port using a

QSFP-to-SFP adapter in the

port

1/10-Gigabit port using a QSFP-to-SFP adapter in the port

Note Even numbered port must use the same speed as

the odd numbered port in the same vertical pair

of ports. Connect the odd numbered port first to

set the speed for the vertical pair of ports.

You can individually configure ports 29 to 32 as follows:

40/100-Gigabit QSFP+/QSFP28 uplink port (default)

40/100-Gigabit QSFP+/QSFP28 uplink port can be individually broken out with the 4x10-Gigabit or

4x25-Gigabit breakout feature.

For information on configuring ports for this switch, see the Cisco Nexus 9000 Series NX-OS

Interfaces Configuration Guide. Also see Cisco 40-Gigabit Ethernet Transceiver Modules Compatibility Matrix | Cisco Nexus 9000 Series (Fixed 9300) https://www.cisco.com/c/en/us/td/docs/interfaces_modules/transceiver_modules/compatibility/matrix/40GE_Tx_Matrix.html#_Toc501460917

B.34.2 For Nexus 93108TC-EX, 93180YC and 9336C-FX2 This also applies to Nexus 93240YC-FX2 and 93360YC and also other family model with 100G QSFP28 ports. Cisco Nexus 93108TC-EX NX-OS Mode Switch Hardware Installation Guide Updated: November 13, 2017 https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/hw/n93108tcex_hig/guide/b_c93108tcex_nxos_mode_hardware_install_guide/b_c93108tcex_nxos_mode_hardware_install_guide_chapter_01011.html#concept_efn_m5q_4x Chapter: Connecting the Switch to the Network

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 147 of 242

Uplink Connections The six 40- and 100-Gigabit Ethernet QSFP28 uplink ports support 4 x 10-Gigabit and 4 x 25-Gigabit breakout cables and 1- and 10-Gigabit Ethernet with QSFP-to-SFP adapters. The six 40- and 100-Gigabit Ethernet QSFP28 uplink ports support 10-, 25-, 40-, 50-, and 100-Gigabit connectivity. You can use 4x10-Gigabit and 4x25-Gigabit breakout cables with these ports. For a list of transceivers and cables used by this switch for uplink connections, see http://www.cisco.com/c/en/us/support/interfaces-modules/transceiver-modules/products-device-support-tables-list.html. interface breakout module 1 port 49 map 10g-4x

This particular command maps the 40GE to become 4 x 10GE. Other options of the command are: LAB_93180YC-EX(config)# interface breakout module 1 port 50 map ?

10g-4x Breaks out a 40G high BW front panel port into four 10G ports

25g-4x Breaks out a 100G high BW front panel port into four 25G ports

50g-2x Breaks out a 100G high BW front panel port into two 50G ports

Software

NXOS: version 7.0(3)I4(2)

BIOS compile time: 08/26/2016

NXOS image file is: bootflash:///nxos.7.0.3.I4.2.bin

NXOS compile time: 7/21/2016 8:00:00 [07/21/2016 16:09:32]

Hardware

cisco Nexus9000 93180YC-EX chassis

The ports would show as shown below, in this example ports 1/1 and 1/1 on a NEXUS 9336C-FX2 are broken out to 10G using the command

interface breakout module 1 port 1-2 map 10g-4x

N9336C-asw02# sh int status

--------------------------------------------------------------------------------

Port Name Status Vlan Duplex Speed Type

--------------------------------------------------------------------------------

Eth1/1/1 10GE link to avid notconnec 14 auto auto QSFP-4X10G-AC10M

Eth1/1/2 link to Avid Nexis connected 18 full 10G QSFP-4X10G-AC10M

Eth1/1/3 ***parked port*** disabled 998 auto auto QSFP-4X10G-AC10M

Eth1/1/4 ***parked port*** disabled 998 auto auto QSFP-4X10G-AC10M

Eth1/2/1 10GE link to avid xcvrAbsen 14 auto auto --

Eth1/2/2 ***parked port*** xcvrAbsen 998 auto auto --

Eth1/2/3 temp isis tests ri xcvrAbsen 171 auto auto --

Eth1/2/4 temp isis tests ri xcvrAbsen 171 auto auto --

Eth1/3 link to Avid Nexis connected 18 full 40G QSFP-H40G-AOC10M

Eth1/4 link to Avid Nexis connected 18 full 40G QSFP-H40G-AOC10M

Depending on the breakout methodology used, it maybe be necessary to apply port speed and duplex commands to the new broken out interfaces.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 148 of 242

B.34.3 Optical breakout useful information A QSA adapter is a simple but inefficient was to make a 40G port become a 10G port. But in fact a QSFP+ is a already four SFP+ combined into a single package and the switch software/configuration defines how the fibers will be “physically” presented as 40G (four lanes of 10G “transmission”) or four independent ports. So, a 40G interface might be e1/49 But once broken out as four 10G ports, they would appear as: e1/49/1 e1/49/2 e1/49/3 e1/49/4 While 40G was a “development” of 10G, not all QSFP+ support breakout so the equipment vendor should be consulted for the correct devices. For Cisco see 40GBASE QSFP Modules Data Sheet: https://www.cisco.com/c/en/us/products/collateral/interfaces-modules/transceiver-modules/data_sheet_c78-660083.html So just as a 40G port can be broken out to a 4 x 10G TWINAX, an optical QSFP+ can to the same thing, it just needs some extra parts for the physical connection. A Have a look at these URLs https://www.fs.com/uk/products/68402.html?gclid=EAIaIQobChMI4eTqq5vN4gIVrL_tCh3xlwMIEAYYAyABEgKV3PD_BwE and https://www.youtube.com/watch?v=HER-Cu83AbI and http://www.fiberopticshare.com/modular-patch-panel-breakout-cabling-choose-future-proofing-network.html Of course, the same principles apply to 100G >> 4 x 25G (or 4x10G). Here are some pictures of product that I found with a Google search of “QSFP breakout panel”. No special cables must be made, a COTS MTP cable connects from the QSFP to the back of the breakout box, and the front provided the LC connection for onward patching to end 10/25G device Outer sheath yellow fibre cables indicate it is a Long Range (LR) optical solution and cyan cable indicate it is a Short Range (SR) optical solution (OM3 or OM4)

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 149 of 242

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 150 of 242

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 151 of 242

GREAT VIDEO https://www.youtube.com/watch?v=HER-Cu83AbI (BROKEN DEC 2020) MTP Breakout Cables Video. https://www.youtube.com/watch?v=kodwHjVDiEc BLACK BOX MTP Connector Rackmount Fiber Solutions. https://www.youtube.com/watch?v=ns-CNrus9dM

MPO connectors and cables | Fiber optic tutorial https://www.youtube.com/watch?v=aDBII83W82Q Explanation of MTP/MPO fibers https://www.youtube.com/watch?v=a1kMpvdc86U Or, in some cases use a simple patch cable like below typically available as 1-100M length:

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 152 of 242

B.34.4 TWINAX breakout useful information Breakout using TWINAX is a little different. Below are some images from a Google search of “TWINAX breakout cable”. These cables are short range, typically 3-5M (passive), no extra patching is required as they are direct point-point connection.

Another great video: Direct Attach Cable (DAC) vs Active Optical Cable (AOC) - Which Do I Need To Buy For My Rack? https://www.youtube.com/watch?v=ACTMTHg-FVk

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 153 of 242

B.34.5 QSA adapter When breakout is not possible/viable, an alternative approach is to use a QSA adapter. This is a physical layer device, so will not need additional testing, however it should not have an adverse impact on buffering characteristics, but it will change the way a port (based on speed) interacts with the buffering.

These devices are usually multivendor capable if purchased from a reputable source. A port using a QSA adapter can use SFP+ transceivers and SFP transceivers. When using a QSA adapter, it may be necessary to apply port speed and duplex commands to the new broken out interfaces, bit in most case this is unlikely as the devices used are likely to have fixed parameters. The use of QSA is a very blunt tool for reducing port speed. It is a very inefficient use of a highly capable port. It is much more efficient to use a QSFP+ device which is capable of breakout s described above.

B.35 What is "=" in Cisco part number? https://supportforums.cisco.com/t5/application-networking/what-is-quot-quot-in-cisco-part-number/td-p/700991 For example: Q. What does the "=" mean in Cisco part number? It seems there is no difference between the parts with a "=" and the parts without a "=", such as "GLC-SX-MM" and "GLC-SX-MM=" A.

A part with the = sign at the end is what is called a "FRU" part; where FRU stands for "Field Replaceable Units".

Those are the parts that can be used as "spare" or be shipped individually to replace damaged units.

The new parts that are ordered directly from a reseller or from Cisco usually don't come with the = sign.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 154 of 242

B.36 LINUX BONDING/TEAMING CONFIGURATION FOR ADAPTERS This example provides the command based on the physical interfaces being called p1p1 and p1p2 and the teamed device being called team0. Of course, the “binding” to the NEXIS clients must still be performed using the documented procedure such as shown below.

30APR 2019 This has not been tested by Engineering, hence not fully ratified, and not fully supported, hence exists in the grey area. IMHO it is better to have it, than not to have it…. Like a space-saver spare tyre. It is not perfect, but better than no spare tyre. It is easily tested to see if it is the “cause” of any problem by removing one of the links! It will prevent more problems than it might create, but it also needs to be deployed by sufficiently skilled technicians as there is also correct config that must exist in the network switch so I would advise any customer that deployed to include network consultant involvement, and get test document to support the deployment. It is an OS function, not a driver function. I would argue with Customer Support (CS) vigorously on behalf of any site that deploys it, that encounters CS inertia.

avidctl platform config nexis --system-name=wavd-nexis --systemdirectors= wavd-nexis1.wavd.com --user=wavdadmin --password=Avid123 -- net-use=team0 --mode=1 Depending on the version of Linux, a GUI option such as NMUTILS might also be available. For CENTOS 7 used by MediaCentral Cloud UX server this resource is very helpful https://www.snel.com/support/setup-lacp-bonding-interface-centos-7/ One of the key files that might need editing is to change the load balancing HASH: nano /etc/sysconfig/network-scripts/ifcfg-bond0 these two articles/URLs below give great information on the xmit_hash_policy=value https://access.redhat.com/documentation/en-us/red_hat_enterprise_linux/7/html/networking_guide/sec-using_channel_bonding https://www.unixmen.com/linux-basics-create-network-bonding-on-centos-76-5/ The default is load balancing hash is layer 2 (parameter=0). But layer 2+3 is a much better (parameter=2). Layer 3+4 should be avoided as it does not work well with the UDP based NEXIS signalling protocol.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 155 of 242

# cat /etc/sysconfig/network-scripts/ifcfg-Bond0

BONDING_OPTS="downdelay=0 miimon=1 mode=802.3ad xmit_hash_policy=2 updelay=0"

TEAMD is a newer teaming/bonding method and is used by NEXIS Engine to control it bonding/teaming and it offers more granular option for Transmit HASH load balancing ( xmit_hash_policy), and the naming of the function is different. runner.tx_hash (array) List of fragment types (strings) which should be used for packet Tx hash computation. The following are available:

eth — Uses source and destination MAC addresses. vlan — Uses VLAN id. ipv4 — Uses source and destination IPv4 addresses. ipv6 — Uses source and destination IPv6 addresses. ip — Uses source and destination IPv4 and IPv6 addresses. l3 — Uses source and destination IPv4 and IPv6 addresses. tcp — Uses source and destination TCP ports. udp — Uses source and destination UDP ports. sctp — Uses source and destination SCTP ports. l4 — Uses source and destination TCP and UDP and SCTP ports.

Beginning with March 2021 NEXIS release the TEAMD configuration will use “l3”. Because it works better with the UDP based NEXIS signalling protocol.

B.36.1 TEXT of COMMANDS for SFT

STEP1 A

ifcfg_p1p1

STEP1B

ifcfg_p1p2

TYPE=Ethernet

PROXY_METHOD=none

BROWSER_ONLY=no

BOOTPROTO=dhcp

DEFROUTE=yes

IPV4_FAILURE_FATAL=no

IPV6INIT=yes

IPV6_AUTOCONF=yes

TYPE=Ethernet

PROXY_METHOD=none

BROWSER_ONLY=no

BOOTPROTO=dhcp

DEFROUTE=yes

IPV4_FAILURE_FATAL=no

IPV6INIT=yes

IPV6_AUTOCONF=yes

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 156 of 242

IPV6_DEFROUTE=yes

IPV6_FAILURE_FATAL=no

IPV6_ADDR_GEN_MODE=stable-privacy

NAME=p1p1

UUID=82f52b69-92e9-3d0b-bf74-f62d5de380e1

DEVICE=p1p1

ONBOOT=yes

AUTOCONNECT_PRIORITY=-999

IPV6_DEFROUTE=yes

IPV6_FAILURE_FATAL=no

IPV6_ADDR_GEN_MODE=stable-privacy

NAME=p1p2

UUID=34668a02-c7c4-3df4-b23a-50837d949d9b

DEVICE=p1p2

ONBOOT=yes

AUTOCONNECT_PRIORITY=-999

STEP 2 A

ifcfg_team0_slave1

STEP2B

ifcfg_team0_slave2

TYPE=Ethernet

NAME=team0_slave1

UUID=fcac276b-94b3-430b-83c3-24120fbbd924

DEVICE=p1p1

ONBOOT=yes

MASTER=team0

SLAVE=yes

MASTER_UUID=c5efe9fc-7c5a-4622-885c-8bceaedc5591

TYPE=Ethernet

NAME=team0_slave2

UUID=8254f867-968c-42d8-8805-f9033855d401

DEVICE=p1p2

ONBOOT=yes

MASTER=team0

SLAVE=yes

MASTER_UUID=c5efe9fc-7c5a-4622-885c-8bceaedc5591

STEP 3

ifcfg_team0

STEP4

Avid registry

DEVICE=team0

BONDING_OPTS="updelay=0 resend_igmp=1 use_carrier=1 miimon=100 arp_all_targets=any min_links=0 downdelay=0 xmit_hash_policy=layer2 primary_reselect=always fail_over_mac=none

arp_validate=none mode=active-backup lp_interval=1 primary=p1p1

all_slaves_active=0 arp_interval=0 ad_select=stable num_unsol_na=1 num_grat_arp=1"

TYPE=Bond

BONDING_MASTER=yes

PROXY_METHOD=none

BROWSER_ONLY=no

BOOTPROTO=none

# Written by nexis agent - modifications will be overwritten

AvidFos\Parameters\UsrvTransport\Hires 1

AvidFos\Parameters\UseIfnames team0

AvidFos\Parameters\RemoteSystemDirectors sda.thk-avid.local

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 157 of 242

IPADDR=172.18.10.34

PREFIX=24

GATEWAY=172.18.10.1

DNS1=172.18.10.28

DNS2=172.18.10.29

DOMAIN=thk-avid.local

DEFROUTE=yes

IPV4_FAILURE_FATAL=no

IPV6INIT=no

NAME=team0

UUID=c5efe9fc-7c5a-4622-885c-8bceaedc5591

ONBOOT=yes

B.36.2 TEXT of COMMANDS for LACP NOTE: SUMMARISED as full details given above for SFT and this is a small variation. It is still necessary to do step 1 and 2 above in section B36.1, this below becomes the NEW STEP 3 for LACP STEP3 for LACP

DEVICE=team0

BONDING_OPTS="resend_igmp=1

updelay=0 use_carrier=1 miimon=100

arp_all_targets=any min_links=0

downdelay=0 xmit_hash_policy=layer2

primary_reselect=always

fail_over_mac=none lp_interval=1

mode=802.3ad all_slaves_active=0

ad_select=stable num_unsol_na=1

num_grat_arp=1"

TYPE=Bond

BONDING_MASTER=yes

PROXY_METHOD=none

BROWSER_ONLY=no

BOOTPROTO=none

IPADDR=172.18.10.34

PREFIX=24

GATEWAY=172.18.10.1

DNS1=172.18.10.28

DNS2=172.18.10.29

DOMAIN=thk-avid.local

DEFROUTE=yes

IPV4_FAILURE_FATAL=no

IPV6INIT=no

NAME=team0

UUID=c5efe9fc-7c5a-4622-885c-

8bceaedc5591

ONBOOT=yes

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 158 of 242

Note: this example uses a default “xmit_hash_policy=0”. (layer2), it would be better to use xmit_hash_policy=2 (layer2+3) because this would use IP addresses and not MAC addresses, which would not have sufficient variation if other end of connection in a different subnet as default gateway mac would always be used. However, some FHRP solution may allow two MAC addresses to be used. Giving some outbound load balancing even at Layer 2 . Using xmit_hash_policy=1”. (layer3+4) should be avoided.

Here is another CENTOS example (FEB2021 deployment), as can be seen the defaults seem to be omitted. [root@TVSppspcux00200 ~]# cat /etc/sysconfig/network-scripts/ifcfg-bond0

BONDING_OPTS="downdelay=0 miimon=1 mode=802.3ad updelay=0"

TYPE=Bond

BONDING_MASTER=yes

PROXY_METHOD=none

BROWSER_ONLY=no

BOOTPROTO=none

IPADDR=172.19.42.62

PREFIX=24

GATEWAY=172.19.42.254

DNS1=172.31.1.52

DNS2=172.31.1.53

DOMAIN=cityF.tv5.org

DEFROUTE=yes

IPV4_FAILURE_FATAL=no

IPV6INIT=yes

IPV6_AUTOCONF=yes

IPV6_DEFROUTE=yes

IPV6_FAILURE_FATAL=no

IPV6_PRIVACY=no

IPV6_ADDR_GEN_MODE=stable-privacy

NAME=bond0

UUID=86e7d2f5-15a0-4b07-9c4a-acee05fa85b9

DEVICE=bond0

ONBOOT=yes

[root@TVSppspcux00200 ~]#

Note: use nmtui as this is a lot better and more reliable than “hacking” away at text files. HOWEVER nmtui will only do the defaults in terms of LACP hash load balancing (i.e. L2-MAC only) choice so it is necessary to then enhance the text files that have been created to select l3 hash load balancing and other options that might be necessary, but also some of these can be added using nmcli.

More info I this RED HAT Linux documentation https://access.redhat.com/documentation/en-us/red_hat_enterprise_linux/7/html/networking_guide/sec-configure_bonding_using_the_text_user_interface_nmtui Ideally read the whole of chapter 7.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 159 of 242

B.36.3 SFT BONDING CONCLUSIONS During customer testing in NOV 2018: SFT Teaming (do not confuse the used of “teaming” here with TEAMD the term teaming used in the sense of Intel NIC teaming) appears unsuited to operation with Media Central Cloud UX Server.

B.36.4 LACP BONDING CONCLUSIONS During customer testing in NOV 2018: LACP Teaming is well suited to operation with Media Central Cloud UX Server. While not seamless, its operation is Robust and predictable. This method should be used in combination with a switch that supports Multi-Chassis Link Aggregation (MLAG).

Note: Linux uses a default “xmit_hash_policy=layer2”, it would be better to use xmit_hash_policy=layer3 because this would use IP addresses and not MAC addresses, which would not have sufficient variation if other end of connection in a different subnet as default gateway mac would always be used. However, some FHRP solutions may allow two MAC addresses to be used. Giving some outbound load balancing even at Layer 2. Using xmit_hash_policy=layer4” should be avoided. Similar principles would apply to Windows Server.

B.36.5 DISCONNECT TESTS CONCLUSIONS During customer testing in NOV 2018: It is far better to have resilient link than single links, it gives choices of how and when to deal with the failure that are not available to single connected machine. The benefits associated with this "unsupported method" greatly exceed the risks.

B.36.6 DEPLOYMENT CONSIDERTATIONS with MEDIA CENTRAL CLOUD UX The Bonded Interface or Teamed Interface (differing techniques for a similar outcome) should be created before the installation of Media Central Cloud UX server, this is because the keep-alive daemon needs to “bind” to the “appropriate” named interface. Deployment of a Bonded Interface or Teamed Interface after the installation of Media Central Cloud UX server will require several configuration files to be modified to re-focus keep-alive communication to the “correct” named interface, as it does not bond to an IP address but to a NAMED interface. At the time of writing (DEC 2020) using teamed/bonded connection is not explicitly supported on Bare Metal server deployments (Linux or Windows), but with Kubernetes Containers the network connection of the Pod/Application is abstracted from the external physical connection, hence there should be no conflict or issues……and many data centres successfully deploy in this manner.

B.36.7 CHECKING/DEBUGGING LACP BOND CONNECTION STATUS in LINUX The URL is an excellent resource for understand how to configure and check in many different LINUX distributions and include the CENTOS use by AVID MCCUX. https://backdrift.org/lacp-configure-network-bonding-linux

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 160 of 242

and https://serverfault.com/questions/810649/how-does-one-diagnose-linux-lacp-issues-at-the-kernel-level The text extracts below are best viewed on a bigger screen but have been squeezed into a table below for comparison convenience. Depending on whether the TEAMD has been used or manual bonding or OS it may be necessary to use different command to extract the LACP connection status. ~]# teamdctl team0 state view -v

https://access.redhat.com/documentation/en-us/red_hat_enterprise_linux/7/html/networking_guide/sec-controlling_teamd_with_teamdctl or $ cat /proc/net/bonding/bond0

MCCUX_LINUX LACP BOND GOOD MediaCentral Cloud_UX SERVER

This port is connected to a switch configured for LACP (in fact a Cisco vPC).

Previously the SWITCH was not configured for LACP but then the LACP config was applied and the switch ports were toggled to bring up the port channel, hence there are some historical errors that would disappear of the LINUX networking was restarted or the device rebooted.

MCCUX_LINUX LACP BOND DOWN MediaCentral Cloud_UX SERVER

This port is connected to a switch NOT YET configured for LACP (in fact a Cisco vPC).

Note that in this example the load balancing hash policy is using the default layer 2. This is not optimal (but it is acceptable) for Avid data flows, as if devices are in different VLANs, MAC addresses will not change much because of default gateway…. However if there is an FHRP in place at least there should be two destination MAC addresses at play so there at least half a change of load balancing….But load balancing decisions are not based on bandwidth balance but a mathematical XOR base algorithm.

# cat /proc/net/bonding/bond0

Ethernet Channel Bonding Driver: v3.7.1

(April 27, 2011)

Bonding Mode: IEEE 802.3ad Dynamic link

aggregation

Transmit Hash Policy: layer2 (0)

MII Status: up

MII Polling Interval (ms): 1

Up Delay (ms): 0

Down Delay (ms): 0

802.3ad info

LACP rate: slow

Min links: 0

$ cat /proc/net/bonding/bond0

Ethernet Channel Bonding Driver: v3.7.1

(April 27 2011)

Bonding Mode: IEEE 802.3ad Dynamic link

aggregation

Transmit Hash Policy: layer2 (0)

MII Status: up

MII Polling Interval (ms): 1

Up Delay (ms): 0

Down Delay (ms): 0

802.3ad info

LACP rate: slow

Min Links: 0

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 161 of 242

Aggregator selection policy (ad_select):

stable

System priority: 65535

System MAC address: 00:60:dd:42:24:fa

Active Aggregator Info:

Aggregator ID: 2

Number of ports: 2

Actor Key: 15

Partner Key: 32831

Partner Mac Address: 00:23:04:ee:be:05

Slave Interface: enp20s0

MII Status: up

Speed: 10000 Mbps

Duplex: full

Link Failure Count: 2

Permanent HW addr: 00:60:dd:42:24:fa

Slave queue ID: 0

Aggregator ID: 2

Actor Churn State: none

Partner Churn State: none

Actor Churned Count: 0

Partner Churned Count: 1

details actor lacp pdu:

system priority: 65535

system mac address: 00:60:dd:42:24:fa

port key: 15

port priority: 255

port number: 1

port state: 61

details partner lacp pdu:

system priority: 4096

system mac address: 00:23:04:ee:be:05

oper key: 32831

port priority: 32768

port number: 265

port state: 61

Slave Interface: ens5

MII Status: up

Speed: 10000 Mbps

Duplex: full

Link Failure Count: 3

Permanent HW addr: 00:60:dd:42:24:fb

Slave queue ID: 0

Aggregator ID: 2

Actor Churn State: none

Partner Churn State: none

Actor Churned Count: 1

Partner Churned Count: 1

details actor lacp pdu:

system priority: 65535

system mac address: 00:60:dd:42:24:fa

port key: 15

port priority: 255

port number: 2

port state: 61

details partner lacp pdu:

system priority: 4096

Aggregator selection policy (ad_select):

stable

System priority : 65535

System MAC address : 00:06:dd:42:24:fa

Active Aggregator Info:

Aggregator ID: 1

Number of ports: 1

Actor Key: 15

Partner Key: 1

Partner Mac Address: 00:00:00:00:00:00

Slave Interface: enp20s0

MII Status: up

Speed: 10000Mbps

Duplex: full

Link Failure Count: 0

Permanent HW addr: 00:60:dd:42:24:fa

Slave queue ID: 0

Aggregator ID: 1

Actor Churn State : none

Partner Churn State: churned

Actor Churn Count : 0

Partner Churn Count: 1

details actor lacp pdu:

System priority : 65535

System MAC address : 00:06:dd:42:24:fa

port key: 15

port priority: 255

port number: 1

port state: 77

details partner lacp pdu:

System priority : 65535

System MAC address : 00:00:00:00:00:00

oper key: 1

port priority: 255

port number: 1

port state: 1

Slave Interface: ens5

MII Status: up

Speed: 10000Mbps

Duplex: full

Link Failure Count: 2

Permanent HW addr: 00:06:dd:42:24:fb

Slave queue ID: 0

Aggregator ID: 2

Actor Churn State : churned

Partner Churn State: churned

Actor Churn Count : 1

Partner Churn Count: 1

details actor lacp pdu:

System priority : 65535

System MAC address : 00:06:dd:42:24:fa

port key: 15

port priority: 255

port number: 2

port state: 69

details partner lacp pdu:

System priority : 65535

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 162 of 242

system mac address: 00:23:04:ee:be:05

oper key: 32831

port priority: 32768

port number: 16649

port state: 61

[root@w0ppspcux00200 ~]#

System MAC address : 00:00:00:00:00:00

oper key: 1

port priority: 255

port number: 1

port state: 1

Note the “oper key” is 32831, when 32768 subtracted = 63, the vpc and po ID used on this port just happened to be 61 too, no coincidence. We will see it the same applies for another po….#61

Note that PORTSTATE=61 is GOOD

OPER KEY is related to local PO reference of switch.

LOCAL MAC ADDRESS 00:06:dd:42:24:fb

ss MYRICOM

This below show that the Transmit Hash Policy has been successfully adjusted

$ cat /proc/net/bonding/bond0

Ethernet Channel Bonding Driver: v3.7.1

(April 27 2011)

Bonding Mode: IEEE 802.3ad Dynamic link

aggregation

Transmit Hash Policy: layer2 (0)

MII Status: up

MII Polling Interval (ms): 1

Up Delay (ms): 0

Down Delay (ms): 0

802.3ad info

LACP rate: slow

Min Links: 0

Aggregator selection policy (ad_select):

stable

System priority : 65535

System MAC address : 00:06:dd:42:25:38

Active Aggregator Info:

Aggregator ID: 1

Number of ports: 2

Actor Key: 15

Partner Key: 32829

Partner Mac Address:

00:23:04:ee:be:05

Slave Interface: enp20s0

MII Status: up

Speed: 10000Mbps

Duplex: full

Link Failure Count: 3

Permanent HW addr: 00:60:dd:42:25:38

Slave queue ID: 0

Aggregator ID: 1

Actor Churn State : none

Partner Churn State: none

[root@w0ppspcux00300 ~]# cat

/proc/net/bonding/bond0

Ethernet Channel Bonding Driver: v3.7.1

(April 27, 2011)

Bonding Mode: IEEE 802.3ad Dynamic link

aggregation

Transmit Hash Policy: layer2+3 (2)

MII Status: up

MII Polling Interval (ms): 1

Up Delay (ms): 0

Down Delay (ms): 0

802.3ad info

LACP rate: slow

Min links: 0

Aggregator selection policy (ad_select):

stable

System priority: 65535

System MAC address: 00:60:dd:42:25:08

Active Aggregator Info:

Aggregator ID: 1

Number of ports: 1

Actor Key: 15

Partner Key: 1

Partner Mac Address:

00:00:00:00:00:00

The all-ZEROS MAC address shows that the LACP is no operations yet

BONDING_OPTS="downdelay=0 miimon=1

mode=802.3ad xmit_hash_policy=2 updelay=0"

This can be added to

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 163 of 242

Actor Churn Count : 0

Partner Churn Count: 1

details actor lacp pdu:

System priority : 65535

System MAC address : 00:06:dd:42:25:38

port key: 15

port priority: 255

port number: 1

port state: 61

details partner lacp pdu:

System priority : 4096

System MAC address : 00:23:04:ee:be:05

oper key: 32829

port priority: 32768

port number: 16641

port state: 61

Slave Interface: ens5

MII Status: up

Speed: 10000Mbps

Duplex: full

Link Failure Count: 2

Permanent HW addr: 00:60:dd:42:25:39

Slave queue ID: 0

Aggregator ID: 1

Actor Churn State : none

Partner Churn State: none

Actor Churn Count : 1

Partner Churn Count: 1

details actor lacp pdu:

System priority : 65535

System MAC address : 00:06:dd:42:25:38

port key: 15

port priority: 255

port number: 2

port state: 61

details partner lacp pdu:

System priority : 4096

System MAC address : 00:23:04:ee:be:05

oper key: 32829

port priority: 32768

port number: 257

port state: 61

/etc/sysconfig/network-scripts/ifcfg-bond0 using nano (or even vi for the bravehearted)

With Cisco NEXUS 9K the parameter OPER KEY can be used to determine the Po Interface number, 32829-32768 = 61 and this port is using po/vpc 61 Note that PORTSTATE=61 is GOOD

NOTES

Port State: 0x61 (Timeout)

.... ...1 = LACP Activity: No

.... ..0. = LACP Timeout: No

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 164 of 242

.... .1.. = Aggregation: yes

.... 1... = Synchronization: Yes

...1 .... = Collecting: Yes

..1. .... = Distributing: Yes

.1.. .... = Defaulted: Yes

0... .... = Expired: No

OPER KEY is related to local PO reference of switch.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 165 of 242

Note: The offered MAC address is the same for each link, is controlled but the sending device in this case vPC, and is the same for every link, but as this is a dedicated segment (not shared/hub) that is not an issue for correct Ethernet operation. CORE2# sh vpc role

vPC Role status

----------------------------------------------------

vPC role : primary

Dual Active Detection Status : 0

vPC system-mac : 00:23:04:ee:be:05

vPC system-priority : 4096

vPC local system-mac : 40:b5:c1:00:a0:27

vPC local role-priority : 120

vPC local config role-priority : 120

vPC peer system-mac : 54:9f:c6:48:82:27

vPC peer role-priority : 120

vPC peer config role-priority : 120

CORE2#

Other useful resources Port state definition for LACP

/* Port state definitions (43.4.2.2 in the 802.3ad standard) */

#define AD_STATE_LACP_ACTIVITY 0x1

#define AD_STATE_LACP_TIMEOUT 0x2

#define AD_STATE_AGGREGATION 0x4

#define AD_STATE_SYNCHRONIZATION 0x8

#define AD_STATE_COLLECTING 0x10

#define AD_STATE_DISTRIBUTING 0x20

#define AD_STATE_DEFAULTED 0x40

#define AD_STATE_EXPIRED 0x80

See this URL for more information and onward references https://access.redhat.com/discussions/3357541 https://www.ieee802.org/3/ad/public/mar99/seaman_1_0399.pdf GOOD STATE

0x61

BAD STATE

0x1

BAD STATE

0x77

#define

AD_STATE_LACP_ACTIVITY

0x1 1 1 1

#define

AD_STATE_LACP_TIMEOUT

0x2 0 0 1

#define

AD_STATE_AGGREGATION

0x4 0 0 1

#define

AD_STATE_SYNCHRONIZATION

0x8 0 0 1

#define

AD_STATE_COLLECTING 0

x10 0 0 1

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 166 of 242

#define

AD_STATE_DISTRIBUTING

0x20 1 0 1

#define

AD_STATE_DEFAULTED

0x40 1 0 1

#define AD_STATE_EXPIRED

0x80 0 0 1

PROBLEM

STATE

0x3d

PROBLEM

STATE

0x3f

#define

AD_STATE_LACP_ACTIVITY

0x1 1 1

#define

AD_STATE_LACP_TIMEOUT

0x2 0 1

#define

AD_STATE_AGGREGATION

0x4 1 1

#define

AD_STATE_SYNCHRONIZATION

0x8 1 1

#define

AD_STATE_COLLECTING 0

x10 1 1

#define

AD_STATE_DISTRIBUTING

0x20 1 1

#define

AD_STATE_DEFAULTED

0x40 0 0

#define AD_STATE_EXPIRED

0x80 0 0

Below is an example of a broken connection due to issue in the server. The root cause of this was a FLAPPING interface which then went into ERRDISABLE status. shutdown wait 10 seconds and no shutdown fixed the issue and interface came up correctly.

Below is an example of a CLEAN BOOT, where LACP is already configured on the switch. Also shown in the bond config files is the xmit_hash_policy=2

Which presents as Transmit Hash Policy: layer2+3 (2)

In the bonding status

$ cat /proc/net/bonding/bond0

Ethernet Channel Bonding Driver: v3.7.1

(April 27 2011)

Bonding Mode: IEEE 802.3ad Dynamic link

aggregation

Transmit Hash Policy: layer2+3 (2)

MII Status: down <<<<<<<<

MII Polling Interval (ms): 1

Up Delay (ms): 0

Down Delay (ms): 0

[root@TVSppspcux00100 ~]# cat /proc/net/bonding/bond0

Ethernet Channel Bonding Driver: v3.7.1

(April 27, 2011)

Bonding Mode: IEEE 802.3ad Dynamic link

aggregation

Transmit Hash Policy: layer2+3 (2)

MII Status: up

MII Polling Interval (ms): 1

Up Delay (ms): 0

Down Delay (ms): 0

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 167 of 242

802.3ad info

LACP rate: slow

Min Links: 0

Aggregator selection policy (ad_select):

stable

System priority : 65535

System MAC address : 00:06:dd:42:25:08

bond bond0 has no active aggregator <<<<

!! TEXT BELOW MISSING

<<<<<<<<<<<<

!! Active Aggregator Info:

!! Aggregator ID: 1

!! Number of ports: 1

!! Actor Key: 15

!! Partner Key: 1

!! Partner Mac Address:

00:00:00:00:00:00

Slave Interface: enp20s0

MII Status: down <<<<<<<<<<<<

Speed: 10000Mbps

Duplex: full

Link Failure Count: 31

Permanent HW addr: 00:60:dd:42:25:08

Slave queue ID: 0

Aggregator ID: 2

Actor Churn State : churned

Partner Churn State: churned

Actor Churn Count : 1

Partner Churn Count: 2

details actor lacp pdu:

System priority : 65535

System MAC address : 00:06:dd:42:25:08

port key: 0

port priority: 255

port number: 1

port state: 5

details partner lacp pdu:

system mac address: 00:23:04:ee:be:05

oper key: 32833 <<<< PO65 OFFERED <<<<

port priority: 32768

port number: 273

port state: 7 <<<<<<<<<<

Slave Interface: ens5

MII Status: down <<<<<<<<<<

Speed: 10000Mbps

Duplex: full

Link Failure Count: 31

Permanent HW addr: 00:06:dd:42:25:09

Slave queue ID: 0

Aggregator ID: 2

Actor Churn State : none

Partner Churn State: churned

Actor Churn Count : 1

Partner Churn Count: 2

details actor lacp pdu:

System priority : 65535

System MAC address :

802.3ad info

LACP rate: slow

Min links: 0

Aggregator selection policy (ad_select):

stable

System priority: 65535

System MAC address: 00:60:dd:42:25:38

Active Aggregator Info:

Aggregator ID: 1

Number of ports: 2

Actor Key: 15

Partner Key: 32829

Partner Mac Address:

00:23:04:ee:be:05

Slave Interface: enp20s0

MII Status: up

Speed: 10000 Mbps

Duplex: full

Link Failure Count: 0

Permanent HW addr: 00:60:dd:42:25:38

Slave queue ID: 0

Aggregator ID: 1

Actor Churn State: monitoring

Partner Churn State: monitoring

Actor Churned Count: 0

Partner Churned Count: 0

details actor lacp pdu:

system priority: 65535

system mac address: 00:60:dd:42:25:38

port key: 15

port priority: 255

port number: 1

port state: 61

details partner lacp pdu:

system priority: 4096

system mac address: 00:23:04:ee:be:05

oper key: 32829

port priority: 32768

port number: 16641

port state: 61

Slave Interface: ens5

MII Status: up

Speed: 10000 Mbps

Duplex: full

Link Failure Count: 0

Permanent HW addr: 00:60:dd:42:25:39

Slave queue ID: 0

Aggregator ID: 1

Actor Churn State: monitoring

Partner Churn State: monitoring

Actor Churned Count: 0

Partner Churned Count: 0

details actor lacp pdu:

system priority: 65535

system mac address: 00:60:dd:42:25:38

port key: 15

port priority: 255

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 168 of 242

00:06:dd:42:25:08 <<<

port key: 0

port priority: 255

port number: 2

port state: 13

details partner lacp pdu:

system mac address: 00:23:04:ee:be:05

oper key: 32833 <<< PO65 OFFERED <<<

port priority: 32768

port number: 16657

port state: 7 <<<<<<<<<<

NOTES

Port State: 0x07

.... ...1 = LACP Activity: Yes

.... ..1. = LACP Timeout: Yes

.... .1.. = Aggregation: Yes

.... 0... = Synchronization: No

...0 .... = Collecting: No

..0. .... = Distributing: No

.0.. .... = Defaulted: No

0... .... = Expired: No

With Cisco NEXUS 9K the parameter OPER KEY can be used to determine the Po Interface number, 32833-32768 = 65 and this port is using po/vpc 65 Note that PORTSTATE=07 is BAD

OPER KEY is related to local PO reference of switch.

port number: 2

port state: 61

details partner lacp pdu:

system priority: 4096

system mac address: 00:23:04:ee:be:05

oper key: 32829

port priority: 32768

port number: 257

port state: 61

[root@TVSppspcux00100 network-scripts]# cat

/etc/sysconfig/network-scripts/ifcfg-Bond0

BONDING_OPTS="downdelay=0 miimon=1

mode=802.3ad xmit_hash_policy=2 updelay=0"

TYPE=Bond

BONDING_MASTER=yes

PROXY_METHOD=none

BROWSER_ONLY=no

BOOTPROTO=none

IPADDR=172.19.42.61

PREFIX=24

GATEWAY=172.19.42.254

DNS1=172.31.1.52

DNS2=172.31.1.53

DOMAIN=cityF.tv5.org

DEFROUTE=yes

IPV4_FAILURE_FATAL=no

IPV6INIT=yes

IPV6_AUTOCONF=yes

IPV6_DEFROUTE=yes

IPV6_FAILURE_FATAL=no

IPV6_PRIVACY=no

IPV6_ADDR_GEN_MODE=stable-privacy

NAME=Bond0

UUID=de3f2498-d152-4be8-a9d5-0e8a2408b5bf

DEVICE=bond0

ONBOOT=yes

[root@TVSppspcux00100 network-scripts]#

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 169 of 242

To summarise the basic of configure and test:

1. Configure the bond BEFORE and NEXIS client is loaded. 2. Configure the bond with xmit_hash_policy=2. To ensure this results in layer2+3 load balancing,

[root@TVSppspcux00100 network-scripts]# cat /etc/sysconfig/network-

scripts/ifcfg-Bond0

BONDING_OPTS="downdelay=0 miimon=1 mode=802.3ad xmit_hash_policy=2 updelay=0"

[root@TVSppspcux00100 ~]# cat /proc/net/bonding/bond0

Ethernet Channel Bonding Driver: v3.7.1 (April 27, 2011)

Bonding Mode: IEEE 802.3ad Dynamic link aggregation

Transmit Hash Policy: layer2+3 (2)

3. Configure NEXIS client to bind with the bonded interface. 4. Test the client with ABU to ensure BW flows from the client across both path and into the client across both paths. 5. Understand that load balancing will only occur to between multiple end points, a single client and a single engine is a single flow therefore will use a single path only, even with two engines the paths may chose a single member.

Note: While the MAC address presented using the command. $ cat /proc/net/bonding/bond0 may be the same, if the oper key is not the same then it is not the same port channel this is an indicator that the connection point are misconfigured or the incorrect porta based on the switch configurration details partner lacp pdu: system mac address: 00:23:04:ee:be:05 oper key: 32833 <<<< PO65 OFFERED <<<< port priority: 32768 port number: 273 port state: 7 <<<<<<<<<< 32833 - 32768 = 65. From CISCO NEXUS 9000 Note on Cisco NEXUS the VPC system MAC may be the same for all Port channels https://serverfault.com/questions/930984/in-a-lacp-bond-do-all-partner-interfaces-need-to-have-the-same-oper-key also helpful. https://access.redhat.com/discussions/3357541 /* Port state definitions (43.4.2.2 in the 802.3ad standard) */ #define AD_STATE_LACP_ACTIVITY 0x1 #define AD_STATE_LACP_TIMEOUT 0x2 #define AD_STATE_AGGREGATION 0x4 #define AD_STATE_SYNCHRONIZATION 0x8 #define AD_STATE_COLLECTING 0x10 #define AD_STATE_DISTRIBUTING 0x20 #define AD_STATE_DEFAULTED 0x40 #define AD_STATE_EXPIRED 0x80

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 170 of 242

Also helpful: https://www.alliedtelesis.com/sites/default/files/documents/configuration-guides/linkag_feature_overview_guide.pdf

Also helpful: http://blog.uninets.com/cisco-nexus-9k-series-port-channel-configuration/ shows some good debugging tip such as show lacp neighbor interface PoXXX

B.36.8 TEAMD or BONDING? Do you prefer and automatic gearbox or a manual gearbox? A rhetorical question but not a sill one…. read on….. From what I have seen of TEAMD is does not really offer many advantages, for “basic teaming” and the way it is used is NEXIS it becomes "bound" to the application/FW version which could be considered a disadvantage. It is not documented (and that frustrates me too) but NEXIS is ALWAYS using “teaming” of sorts, but TEAMD controls what type of teaming from within the GUI, either SFT (or other variations of the same meaning such as MS LBFO or active-backup in *IX speak) or LACP. I think TEAMD is "necessary" to get GUI functionality, while bonding cannot do that (now you understand the reference above to auto vs. manual gearbox!!) Three useful articles below to help the reader understand some more of the fine detail without too much glossy marketecture. Linux has slightly separate definition for Bonding and Teaming. Bonding refers to create a bond or aggregation of two or more links into one in order to provide failover and redundancy to the network. Teaming is a new way implementation of bonding and provides a separate driver. Teaming provides more features and a way towards automation as network manager can handle the interfaces with modular design and hence considered a modern way of handing the interfaces. https://ngelinux.com/difference-between-bonding-and-teaming-in-linux/ https://www.redhat.com/en/blog/if-you-bonding-you-will-love-teaming https://www.admin-magazine.com/Articles/Link-aggregation-with-kernel-bonding-and-the-Team-daemon/(offset)/6 So, after reading those I think one could also use another metaphor… do you want “DIY” or “Silver Service” both have their places and appropriate optimal deployment scenarios. Also look at section 4.6 for details on Naming conventions that have been round for a LONG time, unfortunately every different OS seems to interpret the details a little differently and add a fresh dialect. These RED-HAT hat articles really help to understand help to the differences, between bonding and teaming best to read the whole of both chapters.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 171 of 242

https://access.redhat.com/documentation/en-us/red_hat_enterprise_linux/7/html/networking_guide/sec-configure_bonding_using_the_text_user_interface_nmtui and https://access.redhat.com/documentation/en-us/red_hat_enterprise_linux/7/html/networking_guide/sec-configure_a_network_team_using_the_text_user_interface_nmtui

Note: use nmtui as this is a lot better and more reliable than “hacking” away at text files. HOWEVER nmtui will only do the defaults in terms of LACP hash load balancing (i.e. L2-MAC only) choice so it is necessary to then enhance the text files that have been created to select l3 hash load balancing and other options that might be necessary, but also some of these can be added using nmcli.

In older version sof Linux it was necessary to install teamd separately, but it is generally now includes as standard because of it importance and frequent use.

B.37 Nexus Watch Command (Field-Tip) On a project in NOV 2018, the watch command was used on Nexus 93180 switch to auto refresh the statistics from the interfaces, multiple SSH sessions were used to allow several interfaces to be monitored concurrently. watch sh int e1/17 | section rate

Using the pipe modifier allows a reduces set of pertinent information from the show interface output to be viewed, with regular updating of 2 seconds.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 172 of 242

Some of example output from the screen shot above is show below Every 2.0s: vsh -c "sh int e1/17 | section rate" Wed Nov 21 14:47:17 2018 5 seconds input rate 391224 bits/sec, 164 packets/sec 5 seconds output rate 213456 bits/sec, 148 packets/sec input rate 391.22 Kbps, 164 pps; output rate 213.46 Kbps, 148 pps

B.38 Automating Backing Up Cisco Config Files Below are some articles on automating the backup of config files from Cisco devices

B.38.1CATALYST https://www.cisco.com/c/en/us/support/docs/ios-nx-os-software/ios-software-releases-122-mainline/46741-backup-config.html#ab Backup Configuration to a TFTP Server This example is to save the running config to a TFTP server (10.1.1.1) every Sunday at 23:00: Router(config)#kron policy-list Backup

Router(config-kron-policy)#cli show run | redirect

tftp://10.1.1.1/test.cfg

Router(config-kron-policy)#exit

!

Router(config)#kron occurrence Backup at 23:00 Sun recurring

Router(config-kron-occurrence)#policy-list Backup

B.38.2 NEXUS http://crazyitpro.blogspot.com/2013/07/schedule-automatic-backup-config-in.html Nexus-Sw1(config)#feature scheduler //Enable scheduler service in Nexus

Nexus-Sw1(config)#scheduler job name backup-daily // Job Name

Nexus-Sw1(config)#scheduler aaa-authentication username abcd password

abcd@123 // AAA - Authentication for Job created above (If AAA configured)

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 173 of 242

Nexus-Sw1(config)#scheduler job name backup-daily

copy running-config tftp://192.168.1.23/$(SWITCHNAME)-cfg.$(TIMESTAMP)

//IP of TFTP SERVER , file will saved with switch name and timestamp exit

Nexus-Sw1(config)#scheduler schedule name backup-daily // Setup Schedule to run for the JOB

Nexus-Sw1(config-schedule)# time ?

daily Specify a daily schedule

monthly Specify a monthly schedule

start Specify a future time schedule

weekly Specify a weekly schedule

Example :

Nexus-Sw1(config-schedule)# time start now repeat 00:00:05

Schedule starts from Mon Mar 4 10:44:41 2013

Nexus-Sw1(config-schedule)# job name backup-daily // Job Name to be schedule in Scheduler Nexus-Sw1(config-schedule)# exit

Nexus-Sw1(config)# exit

Nexus-Sw1# show scheduler config

Nexus-Sw1# show scheduler logfile

B38.3 TFTP from NEXUS to TFTP server It is a bit different in NEXUS than Catalyst copy running-config tftp://10.42.10.8/sw1-run-config1.bak vrf default OR can do manually

BEWARE copy run tftp: must use the colon or it copies to a file in NVRAM called “tftp”

B.39 NEXUS 93xxx USEFUL COMMANDS Some tips and tricks….

B.39.1 SHOW COMMANDS NEXUS 93xxx USEFUL COMMANDS FROM SHOW TECH **** See Section B.17 for Cisco Catalyst Using SHOW TECH-SUPPORT on a NEXUS switch is not as useful as it was for Catalyst as now it creates a 200-800MB file with up to 8 million lines (depending on model) rather than a 2MB file, and 99% of it is useless unless “distilled” by a computer. Hence below are listed some of the most useful commands for diagnostic purposes. These should not be pasted in together as one command set, but used individually and saved to a logging file for further analysis !! There might be some syntax variation if used in CATALYST switches Some commands will not apply to L2 only switches or standalone L3 switches*

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 174 of 242

These show commands were taken from NEXUS 7.x show tech-support Some command may differ or not exist between NEXUS versions; or depend on configured features and elements. Some commands may not apply depending on which NEXUS “features” exist in the config file Commands with longer output can use the syntax show command | n to avoid having to keep pressing the space bar to continue. COMPACT SET

NATIVE COMMAND WITH NO MORE COMMAND

show version show module show clock show running-config show interface brief show interface status show interface description show interface counters errors show interface show cdp neighbors show cdp neighbors detail

show version | no-more show module | n show clock | n show running-config | n show interface brief | n show interface status | n show interface description | n show interface counters errors | n show interface | n show cdp neighbors | n show cdp neighbors detail | no-more

WITH NEXUS the commands can be pasted as a single set via telnet and captured into the logging facility of the terminal emulator.

While most of these Cisco NEXUS command should be work in Arista CLI it might be necessary to use | no-more or |no because Arista has a | nz command that can be used to only return non zero data in some commands. 7280SE-64#show interfaces counters errors | ?

LINE Filter command by common Linux tools such as grep/awk/sed/wc

append Append redirected output to URL

begin Start output at the first matching line

exclude Do not print lines matching the given pattern

include Print lines matching the given pattern

json Produce JSON output for this command

no-more Disable pagination for this command

nz Include only non-zero counters

redirect Redirect output to URL

section Include sections that match

tee Copy output to URL FULL SET

NATIVE COMMAND WITH NO MORE COMMAND

show switchname show interface mgmt0 show version show module show clock

show switchname | no-more show interface mgmt0 | n show version | n show module | n show clock | n

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 175 of 242

show running-config show startup-config show interface brief show interface status show interface description show interface counters errors show interface trunk show interface transceiver show interface show port-channel summary show system reset-reason show inventory show environment show hsrp brief show hsrp show vpc brief show vpc ! show ip static-route show ip route ! show cdp all show cdp global show cdp neighbors show cdp neighbors detail show port-channel summary show port-channel usage show port-channel load-balance show vlan show vlan all-ports show lldp neighbors show lldp neighbors detail show spanning-tree active show spanning-tree summary show spanning-tree detail show ip igmp snooping show processes cpu history show interface priority-flow-control

show interface flowcontrol

show running-config | n show startup-config | n ! show interface brief | n show interface status | n show interface description | n show interface counters errors | n show interface trunk | n show interface transceiver | n show interface | n ! show port-channel summary | n show system reset-reason | n show inventory | n show environment | n ! show hsrp brief | n show hsrp | n show vpc brief | n show vpc | n ! show ip static-route | n show ip route | n ! show cdp all | n show cdp global | n show cdp neighbors | n show cdp neighbors detail | n show port-channel summary | n show port-channel usage | n show port-channel load-balance | n show vlan | n show vlan all-ports | n show lldp neighbors | n show lldp neighbors detail | n show spanning-tree active | n show spanning-tree summary | n show spanning-tree detail | n show ip igmp snooping | n show processes cpu history | n show interface priority-flow-control | n

show interface flowcontrol | n

!

SOME COMMAND may not work depending on enable features

WITH NEXUS the commands can be pasted as a single set via telnet and captured into the logging facility of the terminal emulator.

COMMANDS IN BOLD ARE CONFIG DEPENDANT, alternatives :

* show hsrp | glbp | vrrp brief

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 176 of 242

show logging info

show logging logfile

show logging info | n

show logging logfile | no-more

show logging log ….. LAST BECAUSE IT LOOONNNNGG

B.39.2 Show interface counters - Errors only LeafSW-MAS# show interface counters errors

This is a great command, so distil just the counter information but is show ALL the interfaces, and depending on the switch that can be a LOOONNNNGG list and give lot of information about counters that are (hopefully) all zero This worked on a Nexus 93180YC running NXOS 7.x LeafSW-MAS# show interface counters errors | exc " 0 -- 0 0 0 0" | exc " 0 0 0 0 0 0" | no

Depending on the NXOS version it will need a bit of tweaking because different version report counter errors in a differing ways i.e. more/less columns show interface counters errors | exc ― 0 0 0 0 0 0” But a little persistence can save a lot of time. Often the management interfaces always show because the column presentation is different Also…. can use sh int co er shorthand command BEWARE when this document is save as a PDF the spacing will mess up So, the ZEROS section may need to copied from a “REAL” show interface counters errors show command which are zeros to re-cred the text correctly (thanks Adobe!!!) Of course with Arista CLI…….. the -nz command can be used to do this And later version of NXOS have this command: show interface counters errors non-zero

B.39.3 NEXUS copy run start SHORTCUT Those nice people at Cisco decided to stop the use of the wr mem command (or wr for short) in NXOS The command below creates an alias of your choice, mine is wrc (write config) to do this task, but it could be anything (I successfully tried “qaz” too for lazy typist!!), which does not match and existing command. cli alias name wrc copy run start

The full command

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 177 of 242

N9000_EDGE4# copy running-config startup-config

[########################################] 100%

Copy complete, now saving to disk (please wait)...

Copy complete.

N9000_EDGE4#

Cisco standard shortcut

N9000_EDGE4# copy run start

[########################################] 100%

Copy complete, now saving to disk (please wait)...

Copy complete.

N9000_EDGE4#

With the above shortcut

N9000_EDGE4# wrc

[########################################] 100%

Copy complete, now saving to disk (please wait)...

Copy complete.

N9000_EDGE4#

I know which I prefer!!

B.39.4 NEXUS other useful alias SHORTCUTS cli alias name wrc copy run start

cli alias name shc show cdp neighbors

cli alias name shp show port-channel summary

cli alias name shpn show port-channel summary | no-more

cli alias name shv show version

cli alias name shh show hsrp brief

cli alias name shr show running-config

cli alias name shrn show running-config | no-more

cli alias name shri show running-config interface

cli alias name shro show ip route

cli alias name shi show interface

cli alias name shie show interface counters errors

cli alias name shin show interface counters errors non-zero

cli alias name shid show interface description

cli alias name shis show interface status

cli alias name shidn show interface description | no-more

cli alias name shisn show interface status | no-more

cli alias name shma show mac address-table

cli alias name shmai show mac address-table interface

cli alias name shmaa show mac address-table address

cli alias name shv show version

cli alias name shvp show vpc

cli alias name ct configure terminal

cli alias name shvp show vpc

USEFUL commands fore debugging/finding deviecs sh ip arp vlan 465 | in 00:26:55:d9:74:59

sh ip arp vlan 465 | in 00:26:55:d9:74:59

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 178 of 242

sh ip arp vlan 164 | in 00:26:55:D9:76:09

sh ip arp vlan 465 | in 00:26:55:D9:76:09

sh ip arp vlan 164

sh ip arp vlan 465

10.140.165.157

0026.55d9.7459

00:26:55:d9:74:59

ping multicast 224.0.0.1 interface vl 164 count 1

ping multicast 239.255.2.3 interface vl 164 count 1

show mac address-table address f018.98f0.afc2

show mac address-table address

Being a slow and poor typist. I might use my alias cooand above shmaa 9440.c930.7b0d

AVID-9348-EDGE3# show mac address-table address 9440.c930.7b0d

Legend:

* - primary entry, G - Gateway MAC, (R) - Routed MAC, O - Overlay

MAC

age - seconds since last seen,+ - primary entry using vPC Peer-

Link,

(T) - True, (F) - False, C - ControlPlane MAC, ~ - vsan

VLAN MAC Address Type age Secure NTFY Ports

---------+-----------------+--------+---------+------+----+----------------

--

* 164 9440.c930.7b0d dynamic 0 F F Eth1/7

To make copying to TFTP via the management interfaces easier when building configs: cli alias name tvs1 copy run tftp://10.255.255.109/sw1 vrf

management

cli alias name tvs2 copy run tftp://10.255.255.109/sw2 vrf

management

cli alias name tvs3 copy run tftp://10.255.255.109/sw3 vrf

management

cli alias name tvs4 copy run tftp://10.255.255.109/sw4 vrf

management

This assumes there are 4 switches, and each switch will have its OWN version of the alias to avoid confusion.

B.39.5 USEFUL NEXUS COMMANDS FOR MULTICAST DEBUGGING Multicast is the cursed gift that keeps on giving….. well actually consumes huge amounts of debugging time because people (well programmers) actually think it is “better” that using broadcasters for layer 2 discovery. HOW WRONG THEY ARE. Multicast L2 issues due IGMP are a massive time burner.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 179 of 242

These command below will show some of the Multicast addresses in use and who is using them. I would not expect most reader of this document to go anywhere near this level of debugging, but this document is a great repository for the author to keep stuff for future use. mtrace events for IGMP process show ip igmp internal event-history igmp-internal

show ip igmp internal event-history debugs

show ip igmp route vrf all

show ip igmp interface vrf all

show ip igmp snooping vlan <x>

show ip igmp internal

show ip igmp internal errors

show ip igmp groups vrf all summary

show ip igmp internal event-history errors

show ip igmp internal event-history msgs

show ip igmp internal event-history vrf

show ip igmp internal event-history events

show ip igmp internal event-history policy

show ip igmp internal event-history cli

show ip igmp snooping groups detail

show ip igmp snooping explicit-tracking

show ip igmp snooping internal event-history vlan`

PING MULTICAST 224.0.0.1 PING MULTICAST 224.0.0.2 ping multicast 224.0.0.1 int vl [number]

This CLI OUTPUT below shows some content extracted from a show tech support saved form a single NEXUS 90000 switch that was in a live broadcaster environment. MI 1 and 2 connected to eth1/4 and 1/5 on VLAN20. With IP addresses 172.18.10.30 and 31 IGMP

L3VM Lookup Errors: 0

`show ip igmp route vrf all` IGMP Connected Group Membership for VRF "default" - 4 total entries Type: S - Static, D - Dynamic, L - Local, T - SSM Translated, H - Host Proxy Group Address Type Interface Uptime Expires Last Reporter 224.0.1.84 D Vlan20 5w4d 00:02:27 172.18.10.31 224.0.1.85 D Vlan20 5w4d 00:02:29 172.18.10.28 225.0.0.64 D Vlan20 5w4d 00:02:33 172.18.10.180 229.111.112.12 D Vlan20 03:56:43 00:02:33 172.18.10.108

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 180 of 242

`show ip igmp interface vrf all`

IGMP Interfaces for VRF "default", count: 4

Vlan20, Interface status: protocol-up/link-up/admin-up

IP address: 172.18.10.4, IP subnet: 172.18.10.0/24

Active querier: 172.18.10.2, expires: 00:02:22, querier version: 2

Membership count: 4

Old Membership count 0

IGMP version: 2, host version: 2

IGMP query interval: 125 secs, configured value: 125 secs

IGMP max response time: 10 secs, configured value: 10 secs

IGMP startup query interval: 31 secs, configured value: 31 secs

IGMP startup query count: 2

IGMP last member mrt: 1 secs

IGMP last member query count: 2

IGMP group timeout: 260 secs, configured value: 260 secs

IGMP querier timeout: 255 secs, configured value: 255 secs

IGMP unsolicited report interval: 10 secs

IGMP robustness variable: 2, configured value: 2

IGMP reporting for link-local groups: disabled

IGMP interface enable refcount: 1

IGMP interface immediate leave: disabled

IGMP interface suppress v3-gsq: disabled

IGMP VRF name default (id 1)

IGMP Report Policy: None

IGMP Host Proxy: Disabled

IGMP State Limit: None

IGMP interface statistics: (only non-zero values displayed)

General (sent/received):

v2-queries: 2/30760, v2-reports: 0/3359881, v2-leaves: 0/1729

Errors:

Report version mismatch: 7222, Query version mismatch: 0

Unknown IGMP message type: 0

Interface PIM DR: No

Interface vPC SVI: No

Interface vPC CFS statistics:

2019 Nov 8 21:58:04.326740 igmp [25143]: [25573]: Processing clear route

for igmp mpib, for VRF default (172.18.10.30/32, 224.0.1.85/32),

inform_mrib due to MRIB delete-route request

2019 Nov 8 21:57:04.282899 igmp [25143]: [25573]: Processing clear route

for igmp mpib, for VRF default (172.18.10.31/32, 224.0.1.85/32),

inform_mrib due to MRIB delete-route request

2019 Nov 11 13:32:17.548648 igmp [25143]: : Received v2 Report for

224.0.0.251 from 172.18.10.30 (Vlan20)

2019 Nov 11 13:32:17.548648 igmp [25143]: : Received v2 Report for

224.0.0.251 from 172.18.10.30 (Vlan20)

2019 Nov 11 13:32:16.832498 igmp [25143]: : Received v2 Report for

224.0.0.251 from 172.18.10.31 (Vlan20)

2019 Nov 11 13:32:19.768262 igmp [25143]: [25573]: Updating oif entry from

M2RIB PSS forvlan_id = 20, src = 0.0.0.0, grp = 224.0.1.84

2019 Nov 11 13:32:19.768211 igmp [25143]: [25573]: Updating oif entry from

M2RIB PSS forvlan_id = 20, src = 0.0.0.0, grp = 224.0.1.84

2019 Nov 11 13:23:59.285751 igmp [25143]: [25250]: SN: <20> Suppressing

report for (*,224.0.1.84) came on Eth1/5

2019 Nov 11 13:23:59.285744 igmp [25143]: [25250]: SN: <20> Updated oif

Eth1/5 for (*, 224.0.1.84) entry

2019 Nov 11 13:23:59.285729 igmp [25143]: [25250]: SN: <20> Received v2

report: group 224.0.1.84 from 172.18.10.31 on Eth1/5

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 181 of 242

2019 Nov 11 13:23:59.285720 igmp [25143]: [25250]: SN: <20> Process a valid

IGMP packet, pkttype:v2report(22), iif:Eth1/5

2019 Nov 11 13:23:59.166873 igmp [25143]: [25250]: SN: <20> Forwarding to

internal SVI Vlan20 (<vlan 20>)

2019 Nov 11 13:23:59.166863 igmp [25143]: [25250]: SN: <20> Don't forward

back on router-port Po10 .

2019 Nov 11 13:23:59.166859 igmp [25143]: [25250]: SN: <20> Forwarding the

packet to router-ports . (iif Po10)

2019 Nov 11 13:23:59.166849 igmp [25143]: [25250]: SN: <20> Report for

link-local group 224.0.0.252 is ignored

2019 Nov 11 13:23:59.166845 igmp [25143]: [25250]: SN: <20> Received v2

report: group 224.0.0.252 from 172.18.10.171 on Po10

2019 Nov 11 13:23:59.166837 igmp [25143]: [25250]: SN: <20> Process a valid

IGMP packet, pkttype:v2report(22), iif:Po10

2019 Nov 11 13:23:58.998808 igmp [25143]: [25250]: SN: <20> Forwarding to

internal SVI Vlan20 (<vlan 20>)

2019 Nov 11 13:23:58.998743 igmp [25143]: [25250]: SN: <20> Forwarding

packet to router-port Po10 (iod 10) .

2019 Nov 11 13:23:58.998726 igmp [25143]: [25250]: SN: <20> Forwarding the

packet to router-ports . (iif Eth1/4)

2019 Nov 11 13:23:58.998717 igmp [25143]: [25250]: SN: <20> Report for

link-local group 224.0.0.251 is ignored

2019 Nov 11 13:23:58.998712 igmp [25143]: [25250]: SN: <20> Received v2

report: group 224.0.0.251 from 172.18.10.30 on Eth1/4

2019 Nov 11 13:23:58.998705 igmp [25143]: [25250]: SN: <20> Process a valid

IGMP packet, pkttype:v2report(22), iif:Eth1/4

B.40 NEXUS FX2 Models and ISIS STORAGE LIMITATIONS This document is for NEXIS but many systems transition from ISIS to NEXIS and deploy a new switch infrastructure. In Early 2019, as part of a network refresh and NEXIS deployment, one European customer deployed ISIS 7500 on a Nexus 9336C-FX2 (used as an access layer device with a Nexus 9500-EX core) via breakout connection and encountered the same problems as had been seen in 2017 with ISIS 7500 1G windows clients (UDP) but where 10G windows clients (TCP) operated successfully. NEXIS 1G clients operated successfully. This customer site has previously tested with Cisco Nexus 9500 EX with Nexus N93180 YC EX, as described in section 2.3.2.2 Cisco Nexus 9500 EX with Nexus N93180 YC EX of this document. The “solution” was to connect ISIS 7500 (using a breakout connection from a 40/100G port) to a Nexus N93180YC-FX (an alternative/nearby access layer device). This is related to information discussed in NETREQS V1.x section 1.5.7 and summarised in section 1.3.1.2 Cisco Nexus 9348-GC-FXP Field testing (FEB 2018) of this document:

Considering a defect where UDP packages are misclassified as described below. https://bst.cloudapps.cisco.com/bugsearch/bug/CSCva22756

The challenge with 9336C-FX2 is considered to be “structural” and not a physical layer dependency. Customer connected ISIS 7x00 with 4x10G copper breakout (not supported but seems to work), 10G Windows clients worked OK but 1G windows clients did not, so it feels like the same bugs as they had previously “fixed” on 9500-EX core.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 182 of 242

There was not an opportunity to do more extensive testing and pass traffic via the N93180YC-EX and then through the 9336C-FX2 and onto the 9500 chassis. The quick workaround used will suffice for the remaining life of the ISIS 7x00 at customer so there will not incentive to spend time, effort and money on debugging this issue. Hence, we may never know the root cause, only that such a combination needs to be avoided. Any 1G NEXIS or ISIS client connection that use UDP for primary data transport (See NETREQS V1.x section 1.0.4 for more details) client traffic for ISIS storage is likely fail (as at MAY 2019) if is transits an FX2 series product. During data migration from ISIS to NEXIS the “active client” should be placed as close to ISIS storage as possible to mitigate encountering such issues, however such issues would not be expected for 10G connected “transfer/migration) clients.

B.41 Using DHCP with Avid Applications The V1.x NETREQS document for ISIS and Media Central provided some advice on using DHCP. While some of that advice still has general merit it also needs to change with the times, because many of the goalposts have moved. With NEXIS (and MediaCentral) the concept of Zones is less applicable, but the principles still apply. Of course, NEXIS storage itself must use STATIC, there is no provision (at the time of writing) for DHCP and this is not expected to change. Generally, server class devices are fixed so will most likely use a STATIC IP address, but with the correct configuration a DYNAMIC address should be viable, and as devices move into VMs or containers or cloud-based deployments this might become mandatory. There is not a one-shot silver bullet answer that can be offered, because as always “it depends” on various factors. Potentially “statically assigned dynamic addresses” might be solution where the IP address is tied to the MAC address, which make IP renumbering exercises much easier, but that adds a different OAM task if the hardware changes, but can be very helpful in a VMAWARE type of deployment where MAC addresses can be “sticky-coded”. As for workstations/clients, it depends on portable vs. fixed and where they might connect as to the best choice, plus DHCP for Avid client devices in corporate networks will be dependent on customers’ policies. A mobile laptop is likely to get its IP address via DHCP, while dedicated workstation might use either STATIC or DHCP depending on whether it connects via an “Avid” administered network or a corporate IT administered network. When using STATIC IP addresses, the DNS systems must be correctly configured for FORWARD and REVERSE lookup otherwise some Avid application will not work correctly, especially where FQDN is used.

It is important to ensure that Update associated point [PTR] record is checked (or similar function in other DNS servers) for REVERSE lookup to operate correctly, and this should be the default setting. When using DHCP this should also occur by default.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 183 of 242

A FORWARD lookup entry in Windows Server DNS, using a STATIC IP address.

A REVERSE lookup entry in Windows Server DNS using a STATIC IP address.

A FORWARD lookup entry in Windows Server DNS, using a DHCP IP address.

A REVERSE lookup entry in Windows Server DNS using a DHCP IP address.

B.42 IP address allocation with NEXIS and MediaCentral NEXIS storage is much more frugal in its use of IP addresses than ISIS 7x00. Externally, each controller has one IP addresses for an Engine with a single controller, and for dual controllers there will be just two IP addresses per Engine, and all of this exists in a single VLAN. Hence 60 Engines with dual controllers could be squeeze into a /25 subnet, but such an approach has no expansion so is a bad idea, I just want to illustrate a point, Also consider that such a large system would be better of using E5 engines anyway. While with NEXIS everything can be in the same VLAN, but that I not always best depending on many criteria. I like to reduce the “blast radius” and keep my subnets small where viable. Also, for better

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 184 of 242

security implementation I like to have NLE Workstations in a different subnet to NEXIS and MediaCentral Application servers, so different rule sets can be applied easily. Also, sometimes Media Central Cloud UX servers might be in yet another subnet, and Media Central Cloud UX web clients are likely to be on the corporate IT network. When sharing a subnet for servers and users, I tend to prefer putting user devices in the upper half of the subnet and server devices in the lower half, to allow for access lists to be applied if required, and not use “100’s” as a border point, such “borders” should be on “subnet boundaries” such as 64 or 128.

B.43 Navigating Cisco NXOS versions This is not a section about which version is recommended for use with NEXIS storage, or a recommendation on switches. This a little help on finding out about version information on Cisco Nexus switches that are a popular choice for use with Avid systems, of course there are suitable other vendors too. But as Cisco is such a large vendor, searching and finding what you want to know can be a mammoth task. There are three Nexus families that Avid has been deployed ion at many sites are NEXUS 5600, Nexus 7000/7700 and NEXUS 9000 (9300, 93000, 9500) As at JUN 2019 this URL is a great starting point but some of the URLs on this page do not point where might be expected https://www.cisco.com/c/en/us/products/ios-nx-os-software/nx-os/index.html Obviously not wanting to read lots of verbose release notes, and develop an encyclopaedic knowledge (which of course would be a life’s work), this helps to obtain for a simplified version. For instance on Nexus 9000 there is no version 8.x, but on Nexus 7000 there is V8.x but not 8.x as on Nexus 9000. For the Nexus 5600 look here: https://www.cisco.com/c/en/us/support/switches/nexus-5000-series-switches/products-release-notes-list.html For the Nexus 7000 family look here: https://www.cisco.com/c/en/us/support/switches/nexus-7000-series-switches/products-release-notes-list.html For the Nexus 9000 family look here: https://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-release-notes-list.html Beware on this URL , as well as NXOS version, you will find details on ACI versions (which have higher numbers) and “R” versions ( which use different chips and fabrics). Hopefully this will help navigate the nebula.

B.44 FIELD TIP: large file sending While Avid has its own solution for doing this, sometimes you just want a quick and easy solution to get out of a hole which to send large files, without having to sign up. Here are two solutions I have used, because they are simple and work well.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 185 of 242

Domestically I have used WETRANSFER https://wetransfer.com, I like it because: Simple file-sharing, No registration, It's free. It has a 2GB “basic limit”. Also you get “download receipts” Also, I found this one FIREFOX SEND https://send.firefox.com which I like too. Again: Simple file-sharing, No registration, It's free; Plus: you can password protect and also set expiry parameters, it has a 1GB “basic” limit. For a more extensive list checkout this URL: https://www.creativebloq.com/design-tools/send-large-files-clients-free-tools-3132117

B.45 FIELD TIP: Upgrading Nexus 9000 switch firmware The information found on the web generally discussed using SCP with a Cisco account. In many cases this is not possible, and it must be performed locally. One of the first things that MUST be done is to ad these two commands, otherwise it is a non-starter feature scp

feature bash

Use WINSCP The example here shows a machine running Software

BIOS: version 07.56

NXOS: version 7.0(3)I4(2)

BIOS compile time: 06/08/2016

NXOS image file is: bootflash:///nxos.7.0.3.I4.2.bin

NXOS compile time: 7/21/2016 8:00:00 [07/21/2016 11:09:32]

With a bootflash variable of: boot nxos bootflash:/nxos.7.0.3.I4.2.bin it will be upgraded to: NXOS image file is: bootflash:///nxos.7.0.3.I7.4.bin NXOS compile time: 6/14/2018 2:00:00 [06/14/2018 09:49:04] So the bootflash variable. Will need to be changed to: boot nxos bootflash:/nxos.7.0.3.I7.4.bin. once this is done the config must be saved, and then the switch must be reloaded to boot into new code. I left the old code there just in case and there. Was plenty of space available in bootflash techctr-edge3# dir bootflash:

4096 Jan 23 21:08:09 2020 .rpmstore/

4096 Aug 05 04:53:54 2019 .swtam/

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 186 of 242

2097193 Jan 23 11:36:07 2020

20200121_163501_poap_26002_1.log

1128719 Jan 23 17:15:46 2020

20200121_163501_poap_26002_2.log

1048635 Jan 21 19:09:11 2020

20200121_163501_poap_26002_init.log

1777998029 Aug 05 04:50:10 2019 aci-n9000-dk9.14.1.2g.bin

0 Jan 23 21:08:21 2020 bootflash_sync_list

4096 Aug 05 04:46:53 2019 home/

16384 Aug 05 04:45:08 2019 lost+found/

882475008 Aug 05 04:46:50 2019 nxos.7.0.3.I7.1.bin

964875776 Nov 06 09:52:02 2018 nxos.7.0.3.I7.4.bin

0 Jan 23 17:16:35 2020 platform-sdk.cmd

4096 Aug 05 04:54:15 2019 scripts/

4096 Aug 05 04:53:57 2019 virtual-instance/

Usage for bootflash://sup-local

4035223552 bytes used

112688205824 bytes free

116723429376 bytes total

this article is helpful Two features must be enabled on the NEXUS switch (ideally - for safety- they should be removed after the upgrade) and some specific setting need to be made in WIN SCP settings for the site details. https://community.cisco.com/t5/data-center-documents/getting-winscp-on-n9k-to-work-settings-config-required/ta-p/3818490 If you get this error you have not competed all the steps in the URL above

These settings have to be applied to each NEXUS switch that is a destination. Remote directory must be /bootflash Shell command is run bash sudo su The transfer is rather slow expect approx. 20-30 minutes for a 9.3 Code set which it approx. 1.6GB, it does not occur anywhere need line speed

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 187 of 242

BEFORE:

AFTER:

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 188 of 242

B.46 Multicast propagation on DELL switches This section is closely related to section B.20 which is about Dell switches According to this article on 9.14 (saw same for 9.9 too) https://www.dell.com/support/manuals/us/en/04/force10-s4048-on/s4048-on-9.14.0.0-cli/igmp-snooping-commands?guid=guid-d4f08dbc-eeca-4616-9d00-aa954a573972&lang=en-us https://www.dell.com/support/manuals/us/en/04/force10-s4048-on/s4048_on_9.9.0.0_cli_pub/igmp-snooping-commands?guid=guid-d4f08dbc-eeca-4616-9d00-aa954a573972&lang=en-us One might assume that IGMP snooping is not enable by default on an S4048, and that it has to be enable on a VLAN by VLAN basis in which case Link level multicast in 239.x.y.z would be propagated in a similar manner to broadcasts. Looking at a S4048. KLAB_VLTCORE1_RACK4#sh ip igmp snooping ? groups IGMP snooping group membership information interface IGMP snooping interface information mrouter Multicast router ports information KLAB _VLTCORE1_RACK4#sh ip igmp snooping mr KLAB _VLTCORE1_RACK4#sh ip igmp snooping gr KLAB _VLTCORE1_RACK4#sh ip igmp snooping interface KLAB _VLTCORE1_RACK4#

Again, this suggests IGMP snooping it is not active by Default in this switch I connected into a Dell N3024 KLAB_ACCESS05_RACK7#show ip igmp IGMP admin mode................................ Disabled IGMP router-alert check........................ Disabled IGMP INTERFACE STATUS Interface Interface-Mode Operational-Status --------- -------------- ---------------- Vl1 Disabled Non-Operational Vl30 Disabled Non-Operational A similar article seems to suggest the same as above that by default multicast packets are flooded https://www.dell.com/community/Networking-General/N2000-IGMP-snooping-filtering/td-p/4688311 and although this is an old article https://www.dell.com/downloads/global/products/pwcnt/en/app_note_6.pdf it again seems to suggest the same as above that by default multicast packets are flooded on Dell switches

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 189 of 242

Which is not a problem for me as for MediaCentral applications the need only exists in the 239.x.x.x link-local range within a small network diameter of /23 max but more likely /24. DELL have since confirmed

On OS9 and OS6 Dell switches have IGMP disabled and normally flooding is done for multicast. On OS10 it can be different as there it would be enabled by default (at least in later versions).

B.46.1 DELL 0S10 IGMP SNOOPING IGMP snooping uses the information in IGMP packets to generate a forwarding table that associates ports with multicast groups. When switches receive multicast frames, they forward them to their intended receivers. OS10 supports IGMP snooping on virtual local area network (VLAN) interfaces. Effective with OS10 release 10.4.3.0, IGMP snooping is enabled by default. Extract from Pages 830-834. Dell EMC SmartFabric OS10 User Guide Release 10.5.1 ip igmp snooping

Enables IGMP snooping on the specified VLAN interface.

Syntax ip igmp snooping

Parameters None

Default Default Depends on the global configuration.

Command Mode VLAN INTERFACE

Usage

Information

When you enable IGMP snooping globally, the configuration applies to all VLAN interfaces. You can disable IGMP snooping on specified VLAN interfaces. The no version of this command disables IGMP snooping on the specified VLAN interface.

Example

OS10(config)# interface vlan 100

OS10(conf-if-vl-100)# no ip igmp snooping

Supported Releases 10.4.0E(R1) or later

IGMP snooping should be disabled on MediaCentral VLANS that need to use Link Level Layer 2 multicast (239.x.x.x) for local lookup such as Media Indexer NOMI and MCCUX clustering. THIS IS NOT ABOUT MUTLICAST ROUTING.

B.47 Multicast propagation on Arista switches According to the excerpt below from Arista documentation, IGMP snooping can be disabled on a per VLAN basis, allowing the flooding of link-level (used by Media Central), and well-known multicast addresses within a VLAN.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 190 of 242

https://www.arista.com/assets/data/pdf/user-manual/um-eos/Chapters/IGMP%20and%20IGMP%20Snooping.pdf 39.4.1 Enabling Snooping The switch provides two control settings for snooping IGMP packets:

Global settings control the availability of IGMP snooping on the switch. Snooping is globally enabled by default.

Per-VLAN settings control IGMP on individual VLANs. If snooping is enabled on the VLAN, it follows the global snooping state.

The ip igmp snooping command controls the global snooping setting. The ip igmp snooping vlan command configures snooping on individual VLANs. Examples

• This command globally enables snooping on the switch. switch(config)#ip igmp snooping switch(config)#

• This command disables snooping on VLANs 2 through 4. switch(config)#no ip igmp snooping vlan 2-4 switch(config)#

see https://www.arista.com/en/um-eos/eos-igmp-and-igmp-snooping

B.48 Useful cabling information Some informative articles on cabling standard differences to clear the mist. The Difference Between Cat6 vs Cat6A Ethernet Cable (APR 2019) https://www.truecable.com/blogs/cable-academy/cat6-vs-cat6a Demystifying Ethernet Types— Difference between Cat5e, Cat 6, and Cat7 (FEB 2016) https://planetechusa.com/demystifying-ethernet-types-difference-between-cat5e-cat-6-and-cat7/ Great article: How to Decipher the Data Center Fiber Alphabet Soup https://www.commscope.com/Blog/How-to-Decipher-the-Data-Center-Fiber-Alphabet-Soup/ Know your GBASE-SR from your GBASE-DR, and your LR4 from your SR16 and https://en.wikipedia.org/wiki/Terabit_Ethernet

B.49 LACP for NEXIS clients – is it supported? This section results from a customer enquiry in JUN2020 and IS SUBJECT TO CHANGE!!! One of our customers in NALA wants to double check with us the network configuration attached. I do not see a problem, but we would like your blessing since they use Arista switches and my experience with them is limited. As far as I understand, they need path redundancy, but with only one controller inside their NEXIS E2s. I rather have two, but budget limits won’t allow them to do so. The main questions are:

Is LACP Supported on Nexis Clients running Windows 10 Pro Workstations with ATTO NICs?

Is LACP Supported on Nexis Clients running on Mac Pro Workstations with ATTO NICs?

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 191 of 242

I am unaware of ANY testing done at the client level with LACP by Avid Engineering? More is the pity I have been saying we should do this for years, but it never makes the cut. IMHO this is low hanging fruit and I have recently been talking with Dana and Tim about things we need to do better that would be low cost but great benefit. Product Management and Engineering have always gone down the AALB route, which worked well for ISIS/NEXIS but had some unfortunate shortcomings for Interplay (and probably this still lurk in Media central because Asset Management group don’t test NEXIS/resilience features. The last testing I conducted was with ISIS 4.x in 2014 and windows 7 with the Intel driver Pro 1000 series of NICS, while on a PS Job in South Korea I had the opportunity so seized it with both hands. It worked really well with NEXUS 7000 and the M148 1G card, the one small bugbear was that ISIs client only “saw” 1G of BW, but it was the most robust connection I have ever had the pleasure of causing distress in the name of testing and learning. As far as LACP a lot of things have altered with Windows 10 vs 7, the way NIC drivers operate has undergone BIG changes. Interface teaming has always been more of a server class function not client class, after all the Intel Pro 1000 was a server class NIC. I have never done it on a MAC but this Article suggest it will work for OSX 10.14/15. https://support.apple.com/en-gb/guide/mac-help/mchlp2798/mac As per the articles below, later version of Window 10 PRO can do it, perhaps that is why NEXIS engineering stayed well clear…. Limited support for Microsoft an Apple NIC Teaming Windows 10 (Works) https://linustechtips.com/main/topic/1003888-nic-teaming-windows-10-works/

How to Set up Teaming with an Intel® Ethernet Adapter in Windows® 10 1809? https://www.intel.co.uk/content/www/uk/en/support/articles/000032008/network-and-i-o/ethernet-products.html

Windows 10 NIC Teaming, it CAN be done! https://www.reddit.com/r/homelab/comments/a7uszq/windows_10_nic_teaming_it_can_be_done/

LACP does not need MLAG to test, it can be tested on a single switch, and that is where I would start. Of course, for extra BW there is always AALB…. Which is just 2 NIC with discrete IP addresses in the same VLAN. I would be a bit of a science project…. But a good one.

Note: Linux uses a default “xmit_hash_policy=layer2”, it would be better to use xmit_hash_policy=layer3 because this would use IP addresses and not MAC addresses, which would not have sufficient variation if other end of connection in a different subnet as default gateway mac would always be used. However, some FHRP solutions may allow two MAC addresses to be used. Giving some outbound load balancing even at Layer 2. Using xmit_hash_policy=layer4” should be avoided.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 192 of 242

Similar principles would apply to Windows Server.

B.50 Flow control with AVID Nexis storage – is it needed? There are many debates about flow control, and my published vanilla configs do not use it by default. Link Level layer 2 Flow control (802.3x) is a good tool for controlling the flow of data between devices in a single switch, but for devices operating between switches (or when MLAG solutions are deployed??) with a SW-SW interlink the outcome may not be as successful or operate as expected, or operate with some unforeseen outcomes, and need a detailed “matching” configuration in all members of the chain. Which is why Priority Flow Control (PFC; IEEE 802.1Qbb) is better but still needs “careful handling” on networks with multiple switches and SW-SW links as it could suppress the wrong traffic because there is no way to precisely identify the “offending” sender. https://blogs.cisco.com/perspectives/to-flow-or-not-to-flow two good explanation on Priority Flow Control, one from Ivan Pepelnjak and another from Juniper https://blog.ipspace.net/2010/09/introduction-to-8021qbb-priority-flow.html https://www.juniper.net/documentation/en_US/junos/topics/concept/cos-priority-flow-control.html and https://www.cisco.com/c/en/us/products/collateral/switches/nexus-7000-series-switches/white_paper_c11-542809.pdf and some information on deployments commands, simple and complex Also see (ignore vendor or product concentrate on the message) Understanding and Implementing Flow Control on Dell Force10 Switches http://humairahmed.com/blog/?p=5316 Purpose of Ethernet Flow control https://kb.netapp.com/Advice_and_Troubleshooting/Data_Storage_Software/ONTAP_OS/What_is_the_potential_impact_of_PAUSE_frames_on_a_network_connection%3F and https://en.wikipedia.org/wiki/Ethernet_flow_control There are differences in operation for LINK LEVEL flow control versus PRIORITY flow control https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/qos/configuration/guide/b_Cisco_Nexus_9000_Series_NX-OS_Quality_of_Service_Configuration_Guide_7x/b_Cisco_Nexus_9000_Series_NX-OS_Quality_of_Service_Configuration_Guide_7x_chapter_01010.html https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/7-x/qos/configuration/guide/b_Cisco_Nexus_9000_Series_NX-

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 193 of 242

OS_Quality_of_Service_Configuration_Guide_7x/b_Cisco_Nexus_9000_Series_NX-OS_Quality_of_Service_Configuration_Guide_7x_chapter_01011.html

In SEP/OCT 2020 has a customer with multiple 40G engines which were mirrored, and a HEAVY write workflow was a factor. The systems could provide the desired READ bandwidth but could not achieve the desired WRITE bandwidth, only hitting about 60% of target. This customer has 3 x E5 engines (with a fourth due to be added) connecting via two NEXUS 9364C switches (access L2) in an MLAG pair with a 400G vPC peer link and 400G uplinks to core N9364C MLAG pair and the Edge switches were N93180YC with 200G uplinks, so a very capable network, but the “system” appeared to be struggling. Was it the NEXIS or the network? Testing in Burlington indicated a similarly configured NEXIS system with multiple of 2x10G clients could achieve a full WRITE bandwidth. For the desired Media Pack quantity. The WRITE performance increased jumped from 1800MB/S to 3200MB/S (reaching the target figure of 3000MB/S and eventually got to 4000MB/S) when flow control was applied to the NEXUS interface ports facing NEXIS. This size of WRITE bandwidth is an extreme figure and unlikely to feature in the operational workflows for the site, as it was based on all WRITE capable device operating concurrently at full projected load, even 50% of that value is unlikely in normal operation, regardless of whether or not the system was sized to achieve it. They key point here is that when there is a mirrored NEXIS system, there is a lot of cross engine bandwidth to fulfil the mirrored writes, this is different to client bandwidth, but it means the 40G ports are having to work a lot harder. Even though the N9364C is a BIG 100G switch, it has moderate buffers, and the incoming data from the uplinks was considerable. Along with that data between the engines there would have been congestion which cause write request to go unfulfilled between engines which in turn cause a push back on the write requests. This is not the type of congestion that could have been addressed with a QoS profile because all the data was of the same class/value. Also it might not be the Engine/Media-Packs that is struggling but the NIC This is a great example of how the targeted use of Link Level Flow Control (where not using class-based indicator) with in a single switch is the correct approach to maximise performance of similarly capable servers with heavy bidirectional communication. I did not have access to the systems to look at what was happening on the NEXUS switch ports, which apparently did not show interfaces discards or buffer utilisation, before or after flow control was applied. I could not see the full extent of any QoS policies that were associated with the flow control and I am reliably informed that without then a pause frame (802.3x or 802.1Qbb) will have little effect on what the switch is doing.

B.50.1 WHAT TRIGGERS FLOW CONTROL Interesting question!! And again, open to much debate. Is the application pushing back? Is it the NIC pushing back? Is the OS pushing back? Maybe it is a single element or a combination, depending on how the application has been designed. Basically RECEIVE 802.3 flow control is a way for a NIC to exert back pressure for a very short period of time and ask the device that receives the pause frame to stop sending for up to 3.35ms at 10G or 0.83ms at 40G. So, if a receiving NIC in an NLE is having difficulty processing incoming traffic and sending data up the stack, the NIC will issue a pause frame, if connected to a switch it is “asking” the switch to buffer the traffic, but the switch may not send an onward frame to the sending device.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 194 of 242

TRANSMIT 802.3 flow control from a switch would send a pause frame to a sending device (or all ports configured as TX=ON) when its buffer reaches a certain FILL point. As Avid NEXIS does not implement any flow control it is up to the NIC driver and/or OS to react (or not). Consider a NEXUS CLIENT connecting at 40G to a single NEXIS Storage Engine connecting at 40G, there should be no congestion here. In this example a Mac system, specifically a MacPro 7.1 (2019 BIG cheese grater) running OSX 10.15.7 with the Atto N352 40 Gb NIC using Atto’s latest driver (Q3 2020). Not picking on Atto here, it just happened to be used in the MAC workstation that was being ‘tested”. Tested on a Dell S4048 network switch, this single 40G client to a single 40G storage server will perform below expectations when flow control RX=off on client port and (e.g.) <2000MB/S and then with flow control RX=on we get approx. 3200MB/S, no changes made to the storage server port. There should be no oversubscription between the two devices, so no need to send pause frames to/from this switch. Using 40G without Jumbo frames (NEXIS MTU =1500 bytes) will cause a lot of TCP processing to be required, but surely a Modern 40G NIC has sufficient TCP offload capabilities, but it is probable in this case that the NIC needs a little breathing space and each PAUSE if using the maximum quanta value at 4G will cause a 0.8ms hiatus and allow equivalent to approx. 4MB of data

Below is another situation one that WILL cause congestion that can be helped by flow control, regardless of whether devices are 10G or 40G, and it may need RX=ON and TX=ON, because there is a Potential 3:1 oversubscription on the Storage Engines as not only must the WRITE form the NEXIS client be fulfilled, but also the MIRROR write to a different engine. Of cause such congestion will only occur under a HIGH WRITE LOAD scenario

SPEED Gbps

QUANTA

VALUE

65535 milliseconds microseconds

10 3.355 3355.392

25 1.342 1342.157

40 0.839 838.848

100 0.336 335.539

BITS BYTES KB MB

33553920 4194240 4095.938 4.000

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 195 of 242

B.51 Flow control in Cisco NEXUS switches with AVID Nexis storage NEXUS QoS is quite different to Catalyst and deploys many new and innovative tools, but some of the tools supporting elements that are used by default are well hidden. Help gratefully received from my friendly Cisco NEXUS Guru who is well known to many. NOTE AVID NEXIS DOES NOT SUPPORT IEEE 802.1Qbb Priority Flow Control (PFC) at time of writing but commands included for completeness

Configuration - Common config for all switches Network-qos policy applies to all devices as determines which class is non-drop, and as such configuration must be uniform across all switches, all switches will have same configuration: Switch(config-pmap-c-que)# policy-map type network-qos N_AVID_POLICY1 Switch(config-pmap-nqos)# class type network-qos c-8q-nq3

Scenario – Multi-tier or Spine leaf network (no spine Po)

S1 S2

S3 S4 S5S6

1/1, PO100

1/1, PO10

1/1, PO11

1/1, PO11

1/10, PO100

1/11, PO100

1/10, PO100

1/11, PO100

1/20-21, PO1000

1/20-21, PO2000

1/2, PO100

1/3, PO101

1/4, PO101

1/1, PO100

1/2, PO100

1/3, PO101 1/4,

PO101

1/20-21, PO3000

1/10, PO100

1/11, PO101 1/10, PO100

1/11, PO100

1/1, PO10

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 196 of 242

Switch(config-pmap-nqos-c)# pause pfc-cos 3 Switch(config-pmap-nqos-c)# exit Switch(config-pmap-nqos)# Switch(config-pmap-nqos)# system qos Switch(config-sys-qos)# service-policy type network-qos N_AVID_POLICY1

Configuration – Classification on host ports on all switches As traffic coming from the host is not marked with CoS, nor with DSCP, and as Nexus 9000 switch does not support classification based on ACL for non-drop class of traffic, classification is done based on DSCP 0 attached to specific interface: Switch(config)# class-map type qos AVID_TRAFFIC1 Switch(config-cmap-qos)# match dscp 0 Switch(config-cmap-qos)# policy-map type qos AVID_POLICY1 Switch(config-pmap-qos)# class type qos AVID_TRAFFIC1 Switch(config-pmap-c-qos)# set qos-group 3 Switch(config-pmap-c-qos)# set dscp CS3

Traffic is remarked to DSCP CS3 that will be later used for classification on spine layer and on uplinks from spine on leaf switches, into qos-group 3 Switch(config-sys-qos)# interface port-channel 10 - 11 Switch(config-if)# service-policy type qos input AVID_POLICY1 ***** FOR LLFC configuration need on interface ***** Switch(config-sys-qos)# interface port-channel 10 - 11 Switch(config-if)# flowcontrol send on Switch(config-if)# flowcontrol receive on

**** FOR PFC configuration needed on interface**** Switch(config-sys-qos)# interface port-channel 10 - 11 Switch(config-if)# priority-flow-control mode on

Configuration – Classification on uplink ports on leaf switches, and all ports on spine, and peer-link All traffic that we want to match should be marked with DSCP CS3, and we are matching it on uplinks on switch, on peer-link, and on all links on spine: Switch(config)# class-map type qos AVID_TRAFFIC1 Switch(config-cmap-qos)# match dscp CS3 Switch(config-cmap-qos)# policy-map type qos AVID_POLICY1 Switch(config-pmap-qos)# class type qos AVID_TRAFFIC1 Switch(config-pmap-c-qos)# set qos-group 3

Traffic marked as DSCP CS3 is mapped to qos-group 3 on spine layer and on uplinks from spine on leaf switches Switch(config-sys-qos)# interface port-channel 100-101, port-channel 1000 Switch(config-if)# service-policy type qos input AVID_POLICY1

***** FOR LLFC configuration need on interface ***** Switch(config-sys-qos)# interface port-channel 100-101, port-channel 1000, port-channel 2000, port-channel 3000 Switch(config-if)# flowcontrol send on Switch(config-if)# flowcontrol receive on

**** FOR PFC configuration needed on interface**** Switch(config-sys-qos)# interface port-channel 100-101, port-channel 1000, port-channel 2000, port-channel 3000 Switch(config-if)# priority-flow-control mode on

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 197 of 242

Configuration – Queuing and scheduling To simplify configuration, all switches will have same queuing/scheduling configuration. If needed, queueing/scheduling configuration can be adjusted per interface: Switch(config-pmap-c-qos)# policy-map type queuing AVID_EGRESS_QUEUEING Switch(config-pmap-que)# class type queuing c-out-8q-q7 Switch(config-pmap-c-que)# priority level 1 Switch(config-pmap-c-que)# class type queuing c-out-8q-q6 Switch(config-pmap-c-que)# bandwidth remaining percent 0 Switch(config-pmap-c-que)# class type queuing c-out-8q-q5 Switch(config-pmap-c-que)# bandwidth remaining percent 0 Switch(config-pmap-c-que)# class type queuing c-out-8q-q4 Switch(config-pmap-c-que)# bandwidth remaining percent 0 Switch(config-pmap-c-que)# class type queuing c-out-8q-q3 Switch(config-pmap-c-que)# bandwidth remaining percent 60 Switch(config-pmap-c-que)# class type queuing c-out-8q-q2 Switch(config-pmap-c-que)# bandwidth remaining percent 0 Switch(config-pmap-c-que)# class type queuing c-out-8q-q1 Switch(config-pmap-c-que)# bandwidth remaining percent 0 Switch(config-pmap-c-que)# class type queuing c-out-8q-q-default Switch(config-pmap-c-que)# bandwidth remaining percent 40 Switch(config-pmap-nqos)# system qos Switch(config-sys-qos)# service-policy type queuing output AVID_EGRESS_QUEUEING

This uses “built-in” queuing functions that are modified but ONLY WITHIN this queuing policy. Other policies can use these SAME queuing functions differently with another queuing policy. What it looks like when configured. (excluding interface setting) class-map type qos AVID_TRAFFIC1 match dscp 0 policy-map type qos AVID_POLICY1 class type qos AVID_TRAFFIC1 set qos-group 3 set dscp CS3 policy-map type network-qos N_AVID_POLICY1 class type network-qos c-8q-nq3 pause pfc-cos 3 exit system qos service-policy type network-qos N_AVID_POLICY1 policy-map type queuing AVID_EGRESS_QUEUEING class type queuing c-out-8q-q7 priority level 1 class type queuing c-out-8q-q6 bandwidth remaining percent 0 class type queuing c-out-8q-q5 bandwidth remaining percent 0 class type queuing c-out-8q-q4 bandwidth remaining percent 0

class type queuing c-out-8q-q3 bandwidth remaining percent 60 class type queuing c-out-8q-q2 bandwidth remaining percent 0 class type queuing c-out-8q-q1 bandwidth remaining percent 0 class type queuing c-out-8q-q-default bandwidth remaining percent 40 system qos service-policy type queuing output AVID_EGRESS_QUEUEING

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 198 of 242

Flow control activity can be monitored using

show interface flowcontrol For 802.3x or

show interface priority-flow-control For 802.1Qbb This will show information for multiple interfaces e.g. NEW_TEST_3# sh interface flowcontrol | n -------------------------------------------------------------------------------- Port Send FlowControl Receive FlowControl RxPause TxPause admin oper admin oper -------------------------------------------------------------------------------- Eth1/1 off off off off 0 0 Eth1/2 off off off off 0 0 Eth1/3 off off off off 0 0 Eth1/4 off off off off 0 0 Eth1/5 off off off off 0 0 Eth1/6 off off off off 0 0

Or NEW_TEST_3# sh interface priority-flow-control | n

slot 1 ======= ============================================================ Port Mode Oper(VL bmap) RxPPP TxPPP ============================================================

Review PRIMARY QOS commands

show run ipqos | n Or to see the default/hidden commands too (it is a. Long list so use | no-more)

sh run ipqos all | n

B.52 Flow control in Dell S4048 switches with AVID Nexis storage In OS9 for S4048 Dell has a very different way of handling 802.3x flow control in comparison to Cisco. There are no supporting policies needed. Apparently, there is little way to influence the buffer management, the outcome is in the hands of the OS flowcontrol rx {off | on} tx {off | on} [pause- threshold {<1-12480>] [resume-offset <1-12480>] [negotiate]

rx on Enter the keywords rx on to process the received flow control frames on this port.

rx off Enter the keywords rx off to ignore the received flow control frames on this port.

tx on Enter the keywords tx on to send control frames from this port to the connected

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 199 of 242

device when a higher rate of traffic is received.

tx off Enter the keywords tx off so that flow control frames are not sent from this port to the connected device when a higher rate of traffic is received.

pause-threshold

Enter the buffer threshold limit for generating PAUSE frames.

resume-offset

Enter the offset value for generating PAUSE frames to resume traffic.

To monitor is not easy either, EACH interface must be viewed separately (THANKS DELL!!), there is no way to monito all interfaces in one go. Look for THROTTLES in the Input Statistics and Output Statistics of CLI output from show interface command.

B.53 Mellanox ConnectX-3 adapter firmware version in NEXIS The ability of how to obtain this information has only been recently provide to me (NOV 2020) and will not be provide in this document. The firmware version of the Mellanox NIC in the NEXIS controller is not directly related to NEXIS version. It cannot be field-upgraded, hence replacement controllers may have a different version to existing controller. Since mid 2018 new systems should have firmware-version: 2.42.5000. Firmware-version 2.42.5000 This added support for a SINGLE long-range optic 40GbE MC2210511-LR4 Mellanox® optical module, 40Gb/s, QSFP, LC-LC, 1310nm, LR4 up to 10km, which of course will be compatible with Cisco LR Cisco QSFP-40G-LR4-S transceiver at the other end. The maximum TWINAX distance supported in the NEXIS controller NIC remains as 5M Before that systems used firmware-version: 2.40.5030, so as a rough guide, systems delivered in 2017 will probably e fitted with 2.40.5030 which does support 40GbE QSFP-40G-SR-BD Cisco 40G BD Module, but no long range optics Earlier systems 2016 and before will probably have firmware-version: 2_34_5000 In order to confirm driver version, user can go to the agent page of the engine (https://<engine ip or hostname>:5015, go to the Advanced tab and under System Tools use the op3on “Issue Shell Command”. In that window user type “ethtool -i gt0”. If user prefers to use Putty and ssh to the engine, the same information is available using the same command. ALL engines should be checked.

B.54 DELL S4100 OS10 vs. OS9 LACP and VLT commands OS 10 and OS 9 have different syntax. See session 1.1.1 regarding known VLT-LACP to HOST in OS10.5.2.2 that will affect NEXIS and possibly ESXi, and likely to affect other platform operating systems/devices too. OS10 OS9

interface port-channel31 !

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 200 of 242

description NEXIS ENGINE AGGREGATE

no shutdown

switchport access vlan 30

!

interface ethernet1/1/1

description NEXIS CONTROLLER P1

no shutdown

channel-group 31 mode active

no switchport

![flowcontrol receive on]

!

interface ethernet1/1/2

description NEXIS CONTROLLER P2

no shutdown

channel-group 31 mode active

no switchport

![flowcontrol receive on]

NOTE: that the port shows a no

switchport

command for the physical

interface, but this has no

effect because the port is

controlled in in primary

parameters by the port channel,

hence this is a syntactical

peculiarity of the DELL OS10

CLI.

interface Port-channel 70

description PORT CHANNEL TO NEXIS

no ip address

switchport

no shutdown

interface TenGigabitEthernet 1/11

description NEXIS CTLR P1

no ip address

!

port-channel-protocol LACP

port-channel 70 mode active

no shutdown

!

! interface TenGigabitEthernet 1/12

description NEXIS CTLR P2

no ip address

!

port-channel-protocol LACP

port-channel 70 mode active

no shutdown

!

VLT configuration OS10 example VLT configuration OS9 example

interface port-channel1

description NEXIS ENGINE AGGREGATE

no shutdown

switchport access vlan 30

vlt-port-channel 1

!

interface ethernet1/1/1

description NEXIS CONTROLLER P1

no shutdown

channel-group 1 mode active

no switchport

flowcontrol receive on

!

!

interface vlan30

no shutdown

ip address 172.16.30.251/24

!

vrrp-group 30

priority 40

virtual-address 172.16.30.253

!

interface Port-channel 70

description VLT PORT CHANNEL TO NEXIS SDA-

TOP

no ip address

switchport

vlt-peer-lag port-channel 70

no shutdown

interface TenGigabitEthernet 1/11

description NEXIS SDA TOP CT P1

no ip address

!

port-channel-protocol LACP

port-channel 70 mode active

no shutdown

!

!

vlt domain 1

peer-link port-channel 100

back-up destination 169.254.1.2

primary-priority 4096

unit-id 0

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 201 of 242

!

!

vlt-domain 1

backup destination 172.16.30.252

discovery-interface ethernet1/1/25-1/1/28

primary-priority 8192

vlt-mac 00:11:22:33:44:55

!

interface ethernet1/1/25

description VLT SW1-SW2 PEER LINK

no shutdown

no switchport

flowcontrol receive on

!

interface ethernet1/1/26

description VLT SW1-SW2 PEER LINK

no shutdown

no switchport

flowcontrol receive on

!

interface ethernet1/1/27

description VLT SW1-SW2 PEER LINK

no shutdown

no switchport

flowcontrol receive on

!

interface ethernet1/1/28

description VLT SW1-SW2 PEER LINK

no shutdown

no switchport

flowcontrol receive on

!

A corresponding ―almost mirror‖ configuration would be needed in the peer-partner switch.

!

interface TenGigabitEthernet 1/24

description To VLT peer - backup link to

VLTCORE2

ip address 169.254.1.1/28

no shutdown

!

interface Vlan 40

description AVID

ip address 10.21.40.253/24

tagged TenGigabitEthernet 1/4,1/6,1/8

tagged Port-channel 30,40,100

untagged TenGigabitEthernet 1/17,1/19-1/21

untagged Port-channel 70-74,80-84

!

vrrp-group 40

authentication-type simple 7 <<REMOVED>>

priority 90

virtual-address 10.21.40.1

no shutdown!

!

interface fortyGigE 1/53

description To VLT peer link to VLTCORE2

Fo53

no ip address

no shutdown

!

interface fortyGigE 1/54

description To VLT peer link to VLTCORE2

Fo54

no ip address

no shutdown

!

interface Port-channel 100

description To VLT peer PO link to VLTCORE2

no ip address

channel-member fortyGigE 1/53,1/54

no shutdown

!

A corresponding ―almost mirror‖ configuration would be needed in the peer-partner switch.

B.55 CISCO SWITCH HARDWARE BEACONS The NEXUS 9000 and Catalyst 9000 have the ability to remotely activate a blue BEACON LED. Occasionally it might be useful to activate, especially if the project is in one country and the operator in another and you need to identify specific device to remote colleague!!

B.55.1 NEXUS 9000

Syntax Description

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 202 of 242

no Negate a command or set its defaults

locator-led blink locator led on device

chassis blink chassis led

module blink module led

module

Type: integer please enter the module number

fan blink Fan led

fan_num

Type: uinteger min: 1 max: 12 fan number

Command Modes

/exec

locator-led fex [no] locator-led fex chas_no

Syntax Description

no Negate the command

locator-led Turn on locator beacon

fex Blink FEX ID

chas_no

Type: uinteger min: 100 max: 199 FEX number

https://www.cisco.com/c/en/us/td/docs/switches/datacenter/nexus9000/sw/6-x/command_reference/config_612I22/b_n9k_command_ref/b_n9k_command_ref_chapter_01110.html

B.55.2 CATALYST 9000 See these URLs https://www.youtube.com/watch?v=PWFiyiC_OBQ https://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst9500/software/release/16-10/command_reference/b_1610_9500_cr/stackwise_virtual_commands.html#wp3778239026 hw-module beacon switch To control the blue beacon LED in a field-replaceable unit (FRU), use the hw-module beacon switch command in privileged EXEC mode.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 203 of 242

hw-module beacon switch { switch-number| active| standby} { RP{ active| standby} | fan-tray| power-supply power-supply slot number| slot slot number} { off| on| status}

B.56 DELL N3224 FIRST SETUP A kind ASCR has provide the information below, MAR 2021. While not my words, they are worthy of inclusion here.

The DELL N3224 switches, and they are not as straight forward out of the box as the N30XX switches that they effectively replace. Here’s a quick guide that an ACSR has written. The PDF version is here: https://www.dropbox.com/s/3yl7fzr13dvwxo5/Quick%20Setup%20of%20DELL%20N3224%20Switches%20for%20NEXIS%20use.pdf?dl=0

QUICK SETUP OF DELL N3224 SWITCHES FOR NEXIS USE Unlike the earlier 3024 switch the 4 x SFP ports on the front of the 3224 are capable of running at 25GbE OR 10GbE. However, out of the box these ports are NOT set to auto negotiate to the incoming connections speed. If you turn on the unit straight out of the box and plugin an SFP and connect it to a 10GbE source the activity lights will show no activity. To address this, you will have to setup the switch for remote access and change the ports speed. This process can also be achieved using the switches CLI but for people who are not familiar with the commands here’s how to change the ports to be 10GbE through the web interface. SETTING UP THE SWITCH FOR WEB INTERFACE ACCESS You will need to be able to connect to the switch using the serial cable that is supplied (with a 9pin d type!?) so will more than likely need a USB for serial adaptor cable. You can use the DELL Quick Start Guide for a more details break down of setting the system up but here’s quick rundown of how I did this… Power off your switch by pulling the power Connect the serial cable from your laptop to the correct port (labeled 10101) on the DELL switch. Start a terminal session (e.g. using putty) and set it up as follows: Select the appropriate serial port (for me that COM 4) that will connect to the console. Set the data rate to 115,200 Set the data format to 8 data bits, 1 stop bit, and no parity Set the flow control to none Start the serial session Power on the switch. After a few seconds you should be able to see the switches boot code start to appear and populating the serial connection you have established. If this is the first time you have booted the switch you will be asked… Would you like to run the setup wizard (you must answer this question within 60 seconds)? (y/n) At this point enter Y. Follow the onscreen requests to setup the initial access to the switch> Here you will need to be able to supply IP addresses to be used to access it as well as an admin username and password. Once you have this complete you should be able to access the switch using a browser. Login with your username and password.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 204 of 242

At the web interfaces left hand menu navigate to Switching > Ports > Port Configuration. On the Port selection window at the top of this page choose TW1/0/1 from the drop down menu ( this is marked as port 25 on the front of the unit and is the left most SFP slot) Now go to the Admin Port Speed drop down menu and change this from 25000 to 10000. Note that Operational Auto Negotiation is marked as Disable and that the Auto Negotiate Speed radio buttons below cannot be chosen unlike the other 24 copper ports. This is why the port will not switch down to 10GbE automatically. Choose Apply at the bottom of the page to make this port 10GbE. Repeat for other ports as needed.

IMHO, it is probably easier to do this at the CLI ,but as ever it depends on one comfort level at the coal face.

B.57 DELL N3024 N2024 DEFAULT INTERFACE COMMANDS The DELL OS6 CLI is a fearsome opponent for a those well versed in Cisco CLI, some elements and omissions just defy logic, unless you become deeply immersed in the CLI and fin the “New Logic” . Every time I use DELL at the coal-face I curse a lot. The default interface command is a joy in Cisco but is “missing in DELL OS6 until…. https://www.dell.com/community/Networking-General/Delete-all-configuration-from-a-port-N4000-N2000/td-p/6069920

They have this command on version 6.5.3.4: default gi1/0/29 This operation may take a few minutes. The console prompt will return when the operation is complete. Are you sure you want to factory default the interface configuration? (y/n) y

For those who are on lower version this same article contains other useful nuggets that are not TOTALLY accurate, depending on you OS version. Here is what worked for me on a Dell N2024 running version 6.3.2.3

no description no spanning-tree portfast no switchport mode no switchport access vlan no switchport trunk allowed vlan no switchport trunk native vlan

to clean out ! interface Gi1/0/2 switchport mode trunk

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 205 of 242

switchport trunk allowed vlan 153-159 exit to ! interface Gi1/0/2 So I could get to ! interface Gi1/0/2 description "TVS-ESXnn_VM MANAGEMENT CONNECTION_ NON CRITICAL" switchport access vlan 152 exit or for all the gigabit ports in one go interface range gigabitethernet 1/0/1-24 no description no spanning-tree portfast no switchport mode no switchport access vlan no switchport trunk allowed vlan no switchport trunk native vlan ! switchport mode access switchport access vlan 152 description "TVS-ESXnn_VM MANAGEMENT CONNECTION_ NON CRITICAL" Also the interface range command takes some wrangling and “helpfully” DELL OS 6 wants more than just a G or a T for interfaces…. It wants Gi or Te interface range gigabitethernet 1/0/19-20 it also auto fills….you can do int rang go 1/0/19-20

B.58 DELL N3024 N2024 PASSWORD RECOVERY The default Password for Avid supplied switch Dell Networking N3024 (maybe N2024 too) N3048 User: avid Password: avid1234 http://resources.avid.com/SupportFiles/attach/AvidISIS/AvidNetworkSwitchGuide_v4.7.3_Rev_F.pdf URL operational - MAY 2021

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 206 of 242

Also try this….. https://www.dell.com/support/kbdoc/en-uk/000108365/how-to-recover-from-forgotten-password-on-dell-networking-n-series-switch

B.59 SRT LEARNING RESOURCES While this is not a document about MC | STREAM, these you tube URL will help understand how SRT works on the wire. GOOD SRT URL on YOUTUBE HIGH LEVEL https://www.youtube.com/watch?v=rI1EZVc3cNc https://www.youtube.com/watch?v=e5YLItNG3lA https://www.youtube.com/watch?v=kzRJeAYDKEQ DEEPDIVES https://www.youtube.com/watch?v=m1FABQtAjgU https://www.youtube.com/watch?v=MFJeyInLKZY https://www.youtube.com/watch?v=o3BngqPyxd0

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 207 of 242

Appendix C - Power Connections While not strictly networking, this is a good place to locate the information. Historically, Avid products use the standard “kettle” type lead for a power connection and been 100-240V PSU. The IEC 60320 C13 connection or the C15 if it is key like a REAL kettle lead is the standard type of connection is prevalent on PC/Workstations, and has a current rating of 10 Amps. https://en.wikipedia.org/wiki/IEC_60320#C13.2FC14_coupler

Be prepared about power installation of the Cisco Catalyst 4500X – the power supply does not use the common IEC C13/C14 power cable which can normally be found in a data centre rack environment, but the less common C15/C16 power cable. The power cable that is provided with the switch is terminated may be a country-specific wall socket plug, which typically cannot be used in the rack PDU system or even have the wrong county spec. if it was a GREY IMPORT. A possible solution performed successfully many times is to modify the provided C15/C16 power cable and terminate it with the IEC C13/C14 to match the datacentre PDU. This should be considered, planned and executed well in advance to avoid unpleasant surprises at the time of switch installation.

The ISIS 2000/2500 with more demanding power supplies, needs a high current capacity connection and this is the C19 connection and has a current rating of 16 Amps. https://en.wikipedia.org/wiki/IEC_60320#C19.2FC20_coupler

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 208 of 242

Appendix D – NEXIS with MLAG Connections sequence This appendix shows the connection sequence and the CLI output from a switch when enabling a system with aggregated connections

D.1 C4500X VSS and dual controllers in NEXIS This CLI output below is from a VSS pair of C4500X and five E4 engines and and SDA each fitted with dual controllers. The process for do this is well documented in the Avid documentation, but only from a NEXIS perspective, not what happens at the switch. This system has a single SDA with redundant controllers, and five E4 NEXIS engines also with redundant controllers, so that is a total of 24 physical connections all at 10G. The required method is to do basic configuration on the NEXIS engines and prepare them with IP addresses and then to connect them one by one, with the SDA being first. When applying Link aggregation on the controller, this requires a re-start. The CLI output below shows what happens on a C4500X-VSS (it will be slightly different on a NEXUS switch as there is better support for INDIVIDUAL mode of LACP and some command are different). Three useful articles for configuring a VSS from scratch are: Virtual switching system (VSS) Configuration For Cisco 4500 series switches https://supportforums.cisco.com/t5/network-infrastructure-documents/virtual-switching-system-vss-configuration-for-cisco-4500-series/ta-p/3147865 and https://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4500/15-1-2/XE_340/configuration/guide/config/vss.html and Catalyst 4500 Series Switch VSS Member - Replacement Configuration Example https://www.cisco.com/c/en/us/support/docs/switches/catalyst-4500-series-switches/117640-configure-vss-00.html

D.1.1 SDA !! BELOW we have NO SHUT the ports for the SDA, all 4 of them on both controllers !! We gets a message that the ports are not able to join the Aggregate !! - note on NEXUS they will come up in individual mode (I) and not (s)

Enter configuration commands, one per line. End with CNTL/Z.

AVID-CORE1-VSS(config)#int ran t1/1/1-6

AVID-CORE1-VSS(config-if-range)#int range t1/1/1, t1/1/17,t2/1/1, t2/1/17

AVID-CORE1-VSS(config-if-range)#no shut

AVID-CORE1-VSS(config-if-range)#

*Jul 19 07:54:42.223: %EC-5-L3DONTBNDL2: Te1/1/1 suspended: LACP currently not enabled on the

remote port.

*Jul 19 07:54:43.939: %EC-5-L3DONTBNDL2: Te1/1/17 suspended: LACP currently not enabled on

the remote port.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 209 of 242

*Jul 19 07:54:47.124: %EC-5-L3DONTBNDL2: Te2/1/17 suspended: LACP currently not enabled on

the remote port.

*Jul 19 07:54:58.376: %EC-5-L3DONTBNDL2: Te2/1/1 suspended: LACP currently not enabled on the

remote port.

AVID-CORE1-VSS(config-if-range)#do sh etherch

AVID-CORE1-VSS(config-if-range)#do sh etherchannel sum

Flags: D - down P - bundled in port-channel

I - stand-alone s - suspended

H - Hot-standby (LACP only)

R - Layer3 S - Layer2

U - in use f - failed to allocate aggregator

M - not in use, minimum links not met

u - unsuitable for bundling

w - waiting to be aggregated

d - default port

Number of channel-groups in use: 18

Number of aggregators: 18

Group Port-channel Protocol Ports

------+-------------+-----------+-----------------------------------------------

1 Po1(SU) - Te1/1/15(P) Te1/1/16(P) Te1/1/31(P)

Te1/1/32(P)

2 Po2(SU) - Te2/1/15(P) Te2/1/16(P) Te2/1/31(P)

Te2/1/32(P)

10 Po10(SD) LACP Te1/1/1(s) Te2/1/1(s)

11 Po11(SD) LACP Te1/1/2(D) Te2/1/2(D)

12 Po12(SD) LACP Te1/1/3(D) Te2/1/3(D)

13 Po13(SD) LACP Te1/1/4(D) Te2/1/4(D)

14 Po14(SD) LACP Te1/1/5(D) Te2/1/5(D)

15 Po15(SD) LACP Te1/1/6(D) Te2/1/6(D)

40 Po40(SD) LACP Te1/1/17(s) Te2/1/17(s)

41 Po41(SD) LACP Te1/1/18(D) Te2/1/18(D)

42 Po42(SD) LACP Te1/1/19(D) Te2/1/19(D)

43 Po43(SD) LACP Te1/1/20(D) Te2/1/20(D)

44 Po44(SD) LACP Te1/1/21(D) Te2/1/21(D)

45 Po45(SD) LACP Te1/1/22(D) Te2/1/22(D)

91 Po91(SU) LACP Te1/1/24(P) Te2/1/24(P)

92 Po92(SU) LACP Te1/1/25(P) Te2/1/25(P)

93 Po93(SD) LACP Te1/1/26(D) Te2/1/26(D)

94 Po94(SD) LACP Te1/1/27(D) Te2/1/27(D)

!! NOW enable the SDA for LACP and restart the controllers !! then the interfaces come on line, and then the SECOND controller goe off again AVID-CORE1-VSS(config-if-range)#

*Jul 19 07:57:53.040: %EC-5-L3DONTBNDL2: Te2/1/1 suspended: LACP currently not enabled on the

remote port.

*Jul 19 07:58:25.896: %EC-5-L3DONTBNDL2: Te2/1/17 suspended: LACP currently not enabled on

the remote port.

*Jul 19 07:58:57.056: %EC-5-BUNDLE: Interface Te1/1/1 joined port-channel Po10

*Jul 19 07:58:57.152: %EC-5-BUNDLE: Interface Te2/1/1 joined port-channel Po10

*Jul 19 07:58:57.153: %EC-5-BUNDLE: STANDBY:Interface Te1/1/1 joined port-channel Po10

*Jul 19 07:58:57.252: %EC-5-BUNDLE: STANDBY:Interface Te2/1/1 joined port-channel Po10

*Jul 19 07:59:30.336: %EC-5-BUNDLE: Interface Te1/1/17 joined port-channel Po40

*Jul 19 07:59:30.787: %EC-5-BUNDLE: Interface Te2/1/17 joined port-channel Po40

*Jul 19 07:59:30.454: %EC-5-BUNDLE: STANDBY:Interface Te1/1/17 joined port-channel Po40

*Jul 19 07:59:30.887: %EC-5-BUNDLE: STANDBY:Interface Te2/1/17 joined port-channel Po40

*Jul 19 07:59:34.078: %EC-5-UNBUNDLE: Interface Te1/1/17 left the port-channel Po40

*Jul 19 07:59:34.135: %EC-5-UNBUNDLE: Interface Te2/1/17 left the port-channel Po40

*Jul 19 07:59:34.079: %EC-5-UNBUNDLE: STANDBY:Interface Te1/1/17 left the port-channel Po40

*Jul 19 07:59:34.154: %EC-5-UNBUNDLE: STANDBY:Interface Te2/1/17 left the port-channel Po40

AVID-CORE1-VSS(config-if-range)#

!! then see Po10 (SDA 1 TOP) is UP but Po80 (SDA 1 BOTTOM) is NOT AVID-CORE1-VSS(config-if-range)#do sh etherchannel sum

Flags: D - down P - bundled in port-channel

I - stand-alone s - suspended

H - Hot-standby (LACP only)

R - Layer3 S - Layer2

U - in use f - failed to allocate aggregator

M - not in use, minimum links not met

u - unsuitable for bundling

w - waiting to be aggregated

d - default port

Number of channel-groups in use: 18

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 210 of 242

Number of aggregators: 18

Group Port-channel Protocol Ports

------+-------------+-----------+-----------------------------------------------

1 Po1(SU) - Te1/1/15(P) Te1/1/16(P) Te1/1/31(P)

Te1/1/32(P)

2 Po2(SU) - Te2/1/15(P) Te2/1/16(P) Te2/1/31(P)

Te2/1/32(P)

10 Po10(SU) LACP Te1/1/1(P) Te2/1/1(P)

11 Po11(SD) LACP Te1/1/2(D) Te2/1/2(D)

12 Po12(SD) LACP Te1/1/3(D) Te2/1/3(D)

13 Po13(SD) LACP Te1/1/4(D) Te2/1/4(D)

14 Po14(SD) LACP Te1/1/5(D) Te2/1/5(D)

15 Po15(SD) LACP Te1/1/6(D) Te2/1/6(D)

40 Po40(SD) LACP Te1/1/17(D) Te2/1/17(D)

41 Po41(SD) LACP Te1/1/18(D) Te2/1/18(D)

42 Po42(SD) LACP Te1/1/19(D) Te2/1/19(D)

43 Po43(SD) LACP Te1/1/20(D) Te2/1/20(D)

44 Po44(SD) LACP Te1/1/21(D) Te2/1/21(D)

45 Po45(SD) LACP Te1/1/22(D) Te2/1/22(D)

91 Po91(SU) LACP Te1/1/24(P) Te2/1/24(P)

92 Po92(SU) LACP Te1/1/25(P) Te2/1/25(P)

93 Po93(SD) LACP Te1/1/26(D) Te2/1/26(D)

94 Po94(SD) LACP Te1/1/27(D) Te2/1/27(D)

AVID-CORE1-VSS(config-if-range)#

!! then Po80 (SDA 1 BOTTOM) is coming online

*Jul 19 08:01:16.903: %EC-5-BUNDLE: Interface Te1/1/17 joined port-channel Po40

*Jul 19 08:01:16.987: %EC-5-BUNDLE: Interface Te2/1/17 joined port-channel Po40

*Jul 19 08:01:16.989: %EC-5-BUNDLE: STANDBY:Interface Te1/1/17 joined port-channel Po40

*Jul 19 08:01:17.091: %EC-5-BUNDLE: STANDBY:Interface Te2/1/17 joined port-channel Po40

AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#do sh etherchannel sum

Flags: D - down P - bundled in port-channel

I - stand-alone s - suspended

H - Hot-standby (LACP only)

R - Layer3 S - Layer2

U - in use f - failed to allocate aggregator

M - not in use, minimum links not met

u - unsuitable for bundling

w - waiting to be aggregated

d - default port

Number of channel-groups in use: 18

Number of aggregators: 18

Group Port-channel Protocol Ports

------+-------------+-----------+-----------------------------------------------

1 Po1(SU) - Te1/1/15(P) Te1/1/16(P) Te1/1/31(P)

Te1/1/32(P)

2 Po2(SU) - Te2/1/15(P) Te2/1/16(P) Te2/1/31(P)

Te2/1/32(P)

10 Po10(SU) LACP Te1/1/1(P) Te2/1/1(P)

11 Po11(SD) LACP Te1/1/2(D) Te2/1/2(D)

12 Po12(SD) LACP Te1/1/3(D) Te2/1/3(D)

13 Po13(SD) LACP Te1/1/4(D) Te2/1/4(D)

14 Po14(SD) LACP Te1/1/5(D) Te2/1/5(D)

15 Po15(SD) LACP Te1/1/6(D) Te2/1/6(D)

40 Po40(SU) LACP Te1/1/17(P) Te2/1/17(P)

41 Po41(SD) LACP Te1/1/18(D) Te2/1/18(D)

42 Po42(SD) LACP Te1/1/19(D) Te2/1/19(D)

43 Po43(SD) LACP Te1/1/20(D) Te2/1/20(D)

44 Po44(SD) LACP Te1/1/21(D) Te2/1/21(D)

45 Po45(SD) LACP Te1/1/22(D) Te2/1/22(D)

91 Po91(SU) LACP Te1/1/24(P) Te2/1/24(P)

92 Po92(SU) LACP Te1/1/25(P) Te2/1/25(P)

93 Po93(SD) LACP Te1/1/26(D) Te2/1/26(D)

94 Po94(SD) LACP Te1/1/27(D) Te2/1/27(D)

AVID-CORE1-VSS(config-if-range)#

D.1.2 ENGINE 1 !! NOW LETS DO ENGINE 1, the procedure will be the same but with different PO NUMBERS,

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 211 of 242

!! and the intervening states are not shown, !! NOR are enable the ENGINE 1 for LACP and restart the controllers AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#int ran t1/1/2,t1/1/18,t2/1/2,t2/1/18

AVID-CORE1-VSS(config-if-range)#no shut

AVID-CORE1-VSS(config-if-range)#

*Jul 19 08:07:51.399: %EC-5-L3DONTBNDL2: Te2/1/2 suspended: LACP currently not enabled on the

remote port.

*Jul 19 08:07:52.175: %EC-5-L3DONTBNDL2: Te2/1/18 suspended: LACP currently not enabled on

the remote port.

*Jul 19 08:07:56.444: %EC-5-L3DONTBNDL2: Te1/1/18 suspended: LACP currently not enabled on

the remote port.

*Jul 19 08:08:08.676: %EC-5-L3DONTBNDL2: Te1/1/2 suspended: LACP currently not enabled on the

remote port.

*Jul 19 08:09:55.827: %EC-5-L3DONTBNDL2: Te2/1/2 suspended: LACP currently not enabled on the

remote port.

*Jul 19 08:10:05.907: %EC-5-L3DONTBNDL2: Te2/1/18 suspended: LACP currently not enabled on

the remote port.

*Jul 19 08:10:58.564: %EC-5-BUNDLE: Interface Te1/1/18 joined port-channel Po41

*Jul 19 08:10:58.682: %EC-5-BUNDLE: STANDBY:Interface Te1/1/18 joined port-channel Po41

*Jul 19 08:11:00.455: %EC-5-BUNDLE: Interface Te2/1/18 joined port-channel Po41

*Jul 19 08:11:00.764: %EC-5-BUNDLE: Interface Te1/1/2 joined port-channel Po11

*Jul 19 08:11:00.556: %EC-5-BUNDLE: STANDBY:Interface Te2/1/18 joined port-channel Po41

*Jul 19 08:11:00.885: %EC-5-BUNDLE: STANDBY:Interface Te1/1/2 joined port-channel Po11

*Jul 19 08:11:02.536: %EC-5-BUNDLE: Interface Te2/1/2 joined port-channel Po11

*Jul 19 08:11:02.635: %EC-5-BUNDLE: STANDBY:Interface Te2/1/2 joined port-channel Po11

AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#do sh etherchannel sum

Flags: D - down P - bundled in port-channel

I - stand-alone s - suspended

H - Hot-standby (LACP only)

R - Layer3 S - Layer2

U - in use f - failed to allocate aggregator

M - not in use, minimum links not met

u - unsuitable for bundling

w - waiting to be aggregated

d - default port

Number of channel-groups in use: 18

Number of aggregators: 18

Group Port-channel Protocol Ports

------+-------------+-----------+-----------------------------------------------

1 Po1(SU) - Te1/1/15(P) Te1/1/16(P) Te1/1/31(P)

Te1/1/32(P)

2 Po2(SU) - Te2/1/15(P) Te2/1/16(P) Te2/1/31(P)

Te2/1/32(P)

10 Po10(SU) LACP Te1/1/1(P) Te2/1/1(P)

11 Po11(SU) LACP Te1/1/2(P) Te2/1/2(P)

12 Po12(SD) LACP Te1/1/3(D) Te2/1/3(D)

13 Po13(SD) LACP Te1/1/4(D) Te2/1/4(D)

14 Po14(SD) LACP Te1/1/5(D) Te2/1/5(D)

15 Po15(SD) LACP Te1/1/6(D) Te2/1/6(D)

40 Po40(SU) LACP Te1/1/17(P) Te2/1/17(P)

41 Po41(SU) LACP Te1/1/18(P) Te2/1/18(P)

42 Po42(SD) LACP Te1/1/19(D) Te2/1/19(D)

43 Po43(SD) LACP Te1/1/20(D) Te2/1/20(D)

44 Po44(SD) LACP Te1/1/21(D) Te2/1/21(D)

45 Po45(SD) LACP Te1/1/22(D) Te2/1/22(D)

91 Po91(SU) LACP Te1/1/24(P) Te2/1/24(P)

92 Po92(SU) LACP Te1/1/25(P) Te2/1/25(P)

93 Po93(SD) LACP Te1/1/26(D) Te2/1/26(D)

94 Po94(SD) LACP Te1/1/27(D) Te2/1/27(D)

AVID-CORE1-VSS(config-if-range)#

D.1.3 ENGINE 2 !! ENGINE 2 !! and here is what happens when a mistake is made, one port was not turned on correctly due to a typo !! T2/1/13 is enable instead of T2/1/3, so only three ports come up and SH ETHERCHANNEL SUM !! shows that port T2/1/3 is DOWN (D) while others expected ports are just suspended (s) AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#int ran t1/1/3,t1/1/19,t2/1/13,t2/1/19

AVID-CORE1-VSS(config-if-range)#no shut

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 212 of 242

AVID-CORE1-VSS(config-if-range)#

*Jul 19 08:22:57.280: %EC-5-L3DONTBNDL2: Te1/1/3 suspended: LACP currently not enabled on the

remote port.

*Jul 19 08:22:58.524: %EC-5-L3DONTBNDL2: Te1/1/19 suspended: LACP currently not enabled on

the remote port.

*Jul 19 08:23:02.080: %EC-5-L3DONTBNDL2: Te2/1/19 suspended: LACP currently not enabled on

the remote port.

AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#do sh etherchannel sum

Flags: D - down P - bundled in port-channel

I - stand-alone s - suspended

H - Hot-standby (LACP only)

R - Layer3 S - Layer2

U - in use f - failed to allocate aggregator

M - not in use, minimum links not met

u - unsuitable for bundling

w - waiting to be aggregated

d - default port

Number of channel-groups in use: 18

Number of aggregators: 18

Group Port-channel Protocol Ports

------+-------------+-----------+-----------------------------------------------

1 Po1(SU) - Te1/1/15(P) Te1/1/16(P) Te1/1/31(P)

Te1/1/32(P)

2 Po2(SU) - Te2/1/15(P) Te2/1/16(P) Te2/1/31(P)

Te2/1/32(P)

10 Po10(SU) LACP Te1/1/1(P) Te2/1/1(P)

11 Po11(SU) LACP Te1/1/2(P) Te2/1/2(P)

12 Po12(SD) LACP Te1/1/3(s) Te2/1/3(D)

13 Po13(SD) LACP Te1/1/4(D) Te2/1/4(D)

14 Po14(SD) LACP Te1/1/5(D) Te2/1/5(D)

15 Po15(SD) LACP Te1/1/6(D) Te2/1/6(D)

40 Po40(SU) LACP Te1/1/17(P) Te2/1/17(P)

41 Po41(SU) LACP Te1/1/18(P) Te2/1/18(P)

42 Po42(SD) LACP Te1/1/19(s) Te2/1/19(s)

43 Po43(SD) LACP Te1/1/20(D) Te2/1/20(D)

44 Po44(SD) LACP Te1/1/21(D) Te2/1/21(D)

45 Po45(SD) LACP Te1/1/22(D) Te2/1/22(D)

91 Po91(SU) LACP Te1/1/24(P) Te2/1/24(P)

92 Po92(SU) LACP Te1/1/25(P) Te2/1/25(P)

93 Po93(SD) LACP Te1/1/26(D) Te2/1/26(D)

94 Po94(SD) LACP Te1/1/27(D) Te2/1/27(D)

AVID-CORE1-VSS(config-if-range)#int t2/1/3

AVID-CORE1-VSS(config-if)#no shut

AVID-CORE1-VSS(config-if)#int t2/1/13

AVID-CORE1-VSS(config-if)#shut

AVID-CORE1-VSS(config-if)#

*Jul 19 08:25:04.112: %EC-5-L3DONTBNDL2: Te2/1/3 suspended: LACP currently not enabled on the

remote port.

AVID-CORE1-VSS(config-if)#

AVID-CORE1-VSS(config-if)#do sh etherchannel sum

Flags: D - down P - bundled in port-channel

I - stand-alone s - suspended

H - Hot-standby (LACP only)

R - Layer3 S - Layer2

U - in use f - failed to allocate aggregator

M - not in use, minimum links not met

u - unsuitable for bundling

w - waiting to be aggregated

d - default port

Number of channel-groups in use: 18

Number of aggregators: 18

Group Port-channel Protocol Ports

------+-------------+-----------+-----------------------------------------------

1 Po1(SU) - Te1/1/15(P) Te1/1/16(P) Te1/1/31(P)

Te1/1/32(P)

2 Po2(SU) - Te2/1/15(P) Te2/1/16(P) Te2/1/31(P)

Te2/1/32(P)

10 Po10(SU) LACP Te1/1/1(P) Te2/1/1(P)

11 Po11(SU) LACP Te1/1/2(P) Te2/1/2(P)

12 Po12(SD) LACP Te1/1/3(s) Te2/1/3(s)

13 Po13(SD) LACP Te1/1/4(D) Te2/1/4(D)

14 Po14(SD) LACP Te1/1/5(D) Te2/1/5(D)

15 Po15(SD) LACP Te1/1/6(D) Te2/1/6(D)

40 Po40(SU) LACP Te1/1/17(P) Te2/1/17(P)

41 Po41(SU) LACP Te1/1/18(P) Te2/1/18(P)

42 Po42(SD) LACP Te1/1/19(s) Te2/1/19(s)

43 Po43(SD) LACP Te1/1/20(D) Te2/1/20(D)

44 Po44(SD) LACP Te1/1/21(D) Te2/1/21(D)

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 213 of 242

45 Po45(SD) LACP Te1/1/22(D) Te2/1/22(D)

91 Po91(SU) LACP Te1/1/24(P) Te2/1/24(P)

92 Po92(SU) LACP Te1/1/25(P) Te2/1/25(P)

93 Po93(SD) LACP Te1/1/26(D) Te2/1/26(D)

94 Po94(SD) LACP Te1/1/27(D) Te2/1/27(D)

AVID-CORE1-VSS(config-if)#

!! NOW enable the ENGINE 2 for LACP and restart the controllers !! first activity after 1.5 minutes AVID-CORE1-VSS(config-if)#do sh clock

*11:30:41.139 AST Wed Jul 19 2017

AVID-CORE1-VSS(config-if)#

*Jul 19 08:32:03.396: %EC-5-L3DONTBNDL2: Te2/1/19 suspended: LACP currently not enabled on

the remote port.

*Jul 19 08:32:07.984: %EC-5-L3DONTBNDL2: Te2/1/3 suspended: LACP currently not enabled on the

remote port.

*Jul 19 08:33:07.351: %EC-5-BUNDLE: Interface Te1/1/19 joined port-channel Po42

*Jul 19 08:33:07.471: %EC-5-BUNDLE: STANDBY:Interface Te1/1/19 joined port-channel Po42

*Jul 19 08:33:09.147: %EC-5-BUNDLE: Interface Te2/1/19 joined port-channel Po42

*Jul 19 08:33:09.248: %EC-5-BUNDLE: STANDBY:Interface Te2/1/19 joined port-channel Po42

*Jul 19 08:33:12.008: %EC-5-BUNDLE: Interface Te1/1/3 joined port-channel Po12

*Jul 19 08:33:12.127: %EC-5-BUNDLE: STANDBY:Interface Te1/1/3 joined port-channel Po12

*Jul 19 08:33:13.720: %EC-5-BUNDLE: Interface Te2/1/3 joined port-channel Po12

*Jul 19 08:33:13.831: %EC-5-BUNDLE: STANDBY:Interface Te2/1/3 joined port-channel Po12

AVID-CORE1-VSS(config-if)#

AVID-CORE1-VSS(config-if)#do sh etherchannel sum

Flags: D - down P - bundled in port-channel

I - stand-alone s - suspended

H - Hot-standby (LACP only)

R - Layer3 S - Layer2

U - in use f - failed to allocate aggregator

M - not in use, minimum links not met

u - unsuitable for bundling

w - waiting to be aggregated

d - default port

Number of channel-groups in use: 18

Number of aggregators: 18

Group Port-channel Protocol Ports

------+-------------+-----------+-----------------------------------------------

1 Po1(SU) - Te1/1/15(P) Te1/1/16(P) Te1/1/31(P)

Te1/1/32(P)

2 Po2(SU) - Te2/1/15(P) Te2/1/16(P) Te2/1/31(P)

Te2/1/32(P)

10 Po10(SU) LACP Te1/1/1(P) Te2/1/1(P)

11 Po11(SU) LACP Te1/1/2(P) Te2/1/2(P)

12 Po12(SU) LACP Te1/1/3(P) Te2/1/3(P)

13 Po13(SD) LACP Te1/1/4(D) Te2/1/4(D)

14 Po14(SD) LACP Te1/1/5(D) Te2/1/5(D)

15 Po15(SD) LACP Te1/1/6(D) Te2/1/6(D)

40 Po40(SU) LACP Te1/1/17(P) Te2/1/17(P)

41 Po41(SU) LACP Te1/1/18(P) Te2/1/18(P)

42 Po42(SU) LACP Te1/1/19(P) Te2/1/19(P)

43 Po43(SD) LACP Te1/1/20(D) Te2/1/20(D)

44 Po44(SD) LACP Te1/1/21(D) Te2/1/21(D)

45 Po45(SD) LACP Te1/1/22(D) Te2/1/22(D)

91 Po91(SU) LACP Te1/1/24(P) Te2/1/24(P)

92 Po92(SU) LACP Te1/1/25(P) Te2/1/25(P)

93 Po93(SD) LACP Te1/1/26(D) Te2/1/26(D)

94 Po94(SD) LACP Te1/1/27(D) Te2/1/27(D)

AVID-CORE1-VSS(config-if)#do sh clock

*11:33:45.238 AST Wed Jul 19 2017

AVID-CORE1-VSS(config-if)#

!! the Portchannels are online after approx. 3 minutes but the engine is still in the restart cycle.

D.1.4 ENGINE 3 !! and now for engine 3 !! the timestamps have been up dated to local time AVID-CORE1-VSS(config)#int ran t1/1/4, t1/1/20, t2/1/4, t2/1/20

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 214 of 242

AVID-CORE1-VSS(config-if-range)#do sh clock

*11:38:26.304 AST Wed Jul 19 2017

AVID-CORE1-VSS(config-if-range)#no shut

AVID-CORE1-VSS(config-if-range)#

*Jul 19 11:38:46.612: %EC-5-L3DONTBNDL2: Te1/1/20 suspended: LACP currently not enabled on

the remote port.

*Jul 19 11:38:47.239: %EC-5-L3DONTBNDL2: Te1/1/4 suspended: LACP currently not enabled on the

remote port.

*Jul 19 11:38:51.432: %EC-5-L3DONTBNDL2: Te2/1/20 suspended: LACP currently not enabled on

the remote port.

*Jul 19 11:39:00.400: %EC-5-L3DONTBNDL2: Te2/1/4 suspended: LACP currently not enabled on the

remote port.

AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#do sh etherchannel sum

Flags: D - down P - bundled in port-channel

I - stand-alone s - suspended

H - Hot-standby (LACP only)

R - Layer3 S - Layer2

U - in use f - failed to allocate aggregator

M - not in use, minimum links not met

u - unsuitable for bundling

w - waiting to be aggregated

d - default port

Number of channel-groups in use: 18

Number of aggregators: 18

Group Port-channel Protocol Ports

------+-------------+-----------+-----------------------------------------------

1 Po1(SU) - Te1/1/15(P) Te1/1/16(P) Te1/1/31(P)

Te1/1/32(P)

2 Po2(SU) - Te2/1/15(P) Te2/1/16(P) Te2/1/31(P)

Te2/1/32(P)

10 Po10(SU) LACP Te1/1/1(P) Te2/1/1(P)

11 Po11(SU) LACP Te1/1/2(P) Te2/1/2(P)

12 Po12(SU) LACP Te1/1/3(P) Te2/1/3(P)

13 Po13(SD) LACP Te1/1/4(s) Te2/1/4(s)

14 Po14(SD) LACP Te1/1/5(D) Te2/1/5(D)

15 Po15(SD) LACP Te1/1/6(D) Te2/1/6(D)

40 Po40(SU) LACP Te1/1/17(P) Te2/1/17(P)

41 Po41(SU) LACP Te1/1/18(P) Te2/1/18(P)

42 Po42(SU) LACP Te1/1/19(P) Te2/1/19(P)

43 Po43(SD) LACP Te1/1/20(s) Te2/1/20(s)

44 Po44(SD) LACP Te1/1/21(D) Te2/1/21(D)

45 Po45(SD) LACP Te1/1/22(D) Te2/1/22(D)

91 Po91(SU) LACP Te1/1/24(P) Te2/1/24(P)

92 Po92(SU) LACP Te1/1/25(P) Te2/1/25(P)

93 Po93(SD) LACP Te1/1/26(D) Te2/1/26(D)

94 Po94(SD) LACP Te1/1/27(D) Te2/1/27(D)

AVID-CORE1-VSS(config-if-range)#

!! NOW enable the ENGINE 2 for LACP and restart the controllers !! first activity after 1.5 minutes VID-CORE1-VSS(config-if-range)#

*Jul 19 11:40:55.175: %EC-5-L3DONTBNDL2: Te2/1/20 suspended: LACP currently not enabled on

the remote port.

*Jul 19 11:40:55.819: %EC-5-L3DONTBNDL2: Te2/1/4 suspended: LACP currently not enabled on the

remote port.

*Jul 19 11:42:01.020: %EC-5-BUNDLE: Interface Te1/1/4 joined port-channel Po13

*Jul 19 11:42:01.141: %EC-5-BUNDLE: Interface Te1/1/20 joined port-channel Po43

*Jul 19 11:42:01.720: %EC-5-BUNDLE: Interface Te2/1/20 joined port-channel Po43

*Jul 19 11:42:01.895: %EC-5-BUNDLE: Interface Te2/1/4 joined port-channel Po13

*Jul 19 11:42:01.139: %EC-5-BUNDLE: STANDBY:Interface Te1/1/4 joined port-channel Po13

*Jul 19 11:42:01.260: %EC-5-BUNDLE: STANDBY:Interface Te1/1/20 joined port-channel Po43

*Jul 19 11:42:01.830: %EC-5-BUNDLE: STANDBY:Interface Te2/1/20 joined port-channel Po43

*Jul 19 11:42:02.001: %EC-5-BUNDLE: STANDBY:Interface Te2/1/4 joined port-channel Po13

AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#do sh etherchannel sum

Flags: D - down P - bundled in port-channel

I - stand-alone s - suspended

H - Hot-standby (LACP only)

R - Layer3 S - Layer2

U - in use f - failed to allocate aggregator

M - not in use, minimum links not met

u - unsuitable for bundling

w - waiting to be aggregated

d - default port

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 215 of 242

Number of channel-groups in use: 18

Number of aggregators: 18

Group Port-channel Protocol Ports

------+-------------+-----------+-----------------------------------------------

1 Po1(SU) - Te1/1/15(P) Te1/1/16(P) Te1/1/31(P)

Te1/1/32(P)

2 Po2(SU) - Te2/1/15(P) Te2/1/16(P) Te2/1/31(P)

Te2/1/32(P)

10 Po10(SU) LACP Te1/1/1(P) Te2/1/1(P)

11 Po11(SU) LACP Te1/1/2(P) Te2/1/2(P)

12 Po12(SU) LACP Te1/1/3(P) Te2/1/3(P)

13 Po13(SU) LACP Te1/1/4(P) Te2/1/4(P)

14 Po14(SD) LACP Te1/1/5(D) Te2/1/5(D)

15 Po15(SD) LACP Te1/1/6(D) Te2/1/6(D)

40 Po40(SU) LACP Te1/1/17(P) Te2/1/17(P)

41 Po41(SU) LACP Te1/1/18(P) Te2/1/18(P)

42 Po42(SU) LACP Te1/1/19(P) Te2/1/19(P)

43 Po43(SU) LACP Te1/1/20(P) Te2/1/20(P)

44 Po44(SD) LACP Te1/1/21(D) Te2/1/21(D)

45 Po45(SD) LACP Te1/1/22(D) Te2/1/22(D)

91 Po91(SU) LACP Te1/1/24(P) Te2/1/24(P)

92 Po92(SU) LACP Te1/1/25(P) Te2/1/25(P)

93 Po93(SD) LACP Te1/1/26(D) Te2/1/26(D)

94 Po94(SD) LACP Te1/1/27(D) Te2/1/27(D)

AVID-CORE1-VSS(config-if-range)#

D.1.5 ENGINE 4 !! and NOW ENGINE 4 here at 11:52:33 we can see that the PO in DOWN(D) as interfaced are DOWN during AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#int ran t1/1/5,t1/1/21, t2/1/5, t2/1/21

AVID-CORE1-VSS(config-if-range)#no shut

AVID-CORE1-VSS(config-if-range)#do sh clock

*11:50:32.242 AST Wed Jul 19 2017

AVID-CORE1-VSS(config-if-range)#

*Jul 19 11:50:40.744: %EC-5-L3DONTBNDL2: Te1/1/5 suspended: LACP currently not enabled on the

remote port.

*Jul 19 11:50:44.327: %EC-5-L3DONTBNDL2: Te1/1/21 suspended: LACP currently not enabled on

the remote port.

*Jul 19 11:50:46.832: %EC-5-L3DONTBNDL2: Te2/1/21 suspended: LACP currently not enabled on

the remote port.

*Jul 19 11:50:53.432: %EC-5-L3DONTBNDL2: Te2/1/5 suspended: LACP currently not enabled on the

remote port.

AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#do sh etherchannel sum

Flags: D - down P - bundled in port-channel

I - stand-alone s - suspended

H - Hot-standby (LACP only)

R - Layer3 S - Layer2

U - in use f - failed to allocate aggregator

M - not in use, minimum links not met

u - unsuitable for bundling

w - waiting to be aggregated

d - default port

Number of channel-groups in use: 18

Number of aggregators: 18

Group Port-channel Protocol Ports

------+-------------+-----------+-----------------------------------------------

1 Po1(SU) - Te1/1/15(P) Te1/1/16(P) Te1/1/31(P)

Te1/1/32(P)

2 Po2(SU) - Te2/1/15(P) Te2/1/16(P) Te2/1/31(P)

Te2/1/32(P)

10 Po10(SU) LACP Te1/1/1(P) Te2/1/1(P)

11 Po11(SU) LACP Te1/1/2(P) Te2/1/2(P)

12 Po12(SU) LACP Te1/1/3(P) Te2/1/3(P)

13 Po13(SU) LACP Te1/1/4(P) Te2/1/4(P)

14 Po14(SD) LACP Te1/1/5(s) Te2/1/5(s)

15 Po15(SD) LACP Te1/1/6(D) Te2/1/6(D)

40 Po40(SU) LACP Te1/1/17(P) Te2/1/17(P)

41 Po41(SU) LACP Te1/1/18(P) Te2/1/18(P)

42 Po42(SU) LACP Te1/1/19(P) Te2/1/19(P)

43 Po43(SU) LACP Te1/1/20(P) Te2/1/20(P)

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 216 of 242

44 Po44(SD) LACP Te1/1/21(s) Te2/1/21(s)

45 Po45(SD) LACP Te1/1/22(D) Te2/1/22(D)

91 Po91(SU) LACP Te1/1/24(P) Te2/1/24(P)

92 Po92(SU) LACP Te1/1/25(P) Te2/1/25(P)

93 Po93(SD) LACP Te1/1/26(D) Te2/1/26(D)

94 Po94(SD) LACP Te1/1/27(D) Te2/1/27(D)

AVID-CORE1-VSS(config-if-range)#do sh clock

*11:51:16.817 AST Wed Jul 19 2017

AVID-CORE1-VSS(config-if-range)#

*Jul 19 11:52:33.504: %EC-5-L3DONTBNDL2: Te2/1/21 suspended: LACP currently not enabled on

the remote port.

*Jul 19 11:52:38.067: %EC-5-L3DONTBNDL2: Te2/1/5 suspended: LACP currently not enabled on the

remote port.

AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#do sh etherchannel sum

Flags: D - down P - bundled in port-channel

I - stand-alone s - suspended

H - Hot-standby (LACP only)

R - Layer3 S - Layer2

U - in use f - failed to allocate aggregator

M - not in use, minimum links not met

u - unsuitable for bundling

w - waiting to be aggregated

d - default port

Number of channel-groups in use: 18

Number of aggregators: 18

Group Port-channel Protocol Ports

------+-------------+-----------+-----------------------------------------------

1 Po1(SU) - Te1/1/15(P) Te1/1/16(P) Te1/1/31(P)

Te1/1/32(P)

2 Po2(SU) - Te2/1/15(P) Te2/1/16(P) Te2/1/31(P)

Te2/1/32(P)

10 Po10(SU) LACP Te1/1/1(P) Te2/1/1(P)

11 Po11(SU) LACP Te1/1/2(P) Te2/1/2(P)

12 Po12(SU) LACP Te1/1/3(P) Te2/1/3(P)

13 Po13(SU) LACP Te1/1/4(P) Te2/1/4(P)

14 Po14(SD) LACP Te1/1/5(D) Te2/1/5(D)

15 Po15(SD) LACP Te1/1/6(D) Te2/1/6(D)

40 Po40(SU) LACP Te1/1/17(P) Te2/1/17(P)

41 Po41(SU) LACP Te1/1/18(P) Te2/1/18(P)

42 Po42(SU) LACP Te1/1/19(P) Te2/1/19(P)

43 Po43(SU) LACP Te1/1/20(P) Te2/1/20(P)

44 Po44(SD) LACP Te1/1/21(D) Te2/1/21(D)

45 Po45(SD) LACP Te1/1/22(D) Te2/1/22(D)

91 Po91(SU) LACP Te1/1/24(P) Te2/1/24(P)

92 Po92(SU) LACP Te1/1/25(P) Te2/1/25(P)

93 Po93(SD) LACP Te1/1/26(D) Te2/1/26(D)

94 Po94(SD) LACP Te1/1/27(D) Te2/1/27(D)

AVID-CORE1-VSS(config-if-range)#

*Jul 19 11:53:38.892: %EC-5-BUNDLE: Interface Te1/1/21 joined port-channel Po44

*Jul 19 11:53:38.939: %EC-5-BUNDLE: Interface Te2/1/21 joined port-channel Po44

*Jul 19 11:53:38.940: %EC-5-BUNDLE: STANDBY:Interface Te1/1/21 joined port-channel Po44

*Jul 19 11:53:39.064: %EC-5-BUNDLE: STANDBY:Interface Te2/1/21 joined port-channel Po44

*Jul 19 11:53:44.047: %EC-5-BUNDLE: Interface Te1/1/5 joined port-channel Po14

*Jul 19 11:53:44.055: %EC-5-BUNDLE: Interface Te2/1/5 joined port-channel Po14

*Jul 19 11:53:44.058: %EC-5-BUNDLE: STANDBY:Interface Te1/1/5 joined port-channel Po14

*Jul 19 11:53:44.194: %EC-5-BUNDLE: STANDBY:Interface Te2/1/5 joined port-channel Po14

AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#do sh etherchannel sum

Flags: D - down P - bundled in port-channel

I - stand-alone s - suspended

H - Hot-standby (LACP only)

R - Layer3 S - Layer2

U - in use f - failed to allocate aggregator

M - not in use, minimum links not met

u - unsuitable for bundling

w - waiting to be aggregated

d - default port

Number of channel-groups in use: 18

Number of aggregators: 18

Group Port-channel Protocol Ports

------+-------------+-----------+-----------------------------------------------

1 Po1(SU) - Te1/1/15(P) Te1/1/16(P) Te1/1/31(P)

Te1/1/32(P)

2 Po2(SU) - Te2/1/15(P) Te2/1/16(P) Te2/1/31(P)

Te2/1/32(P)

10 Po10(SU) LACP Te1/1/1(P) Te2/1/1(P)

11 Po11(SU) LACP Te1/1/2(P) Te2/1/2(P)

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 217 of 242

12 Po12(SU) LACP Te1/1/3(P) Te2/1/3(P)

13 Po13(SU) LACP Te1/1/4(P) Te2/1/4(P)

14 Po14(SU) LACP Te1/1/5(P) Te2/1/5(P)

15 Po15(SD) LACP Te1/1/6(D) Te2/1/6(D)

40 Po40(SU) LACP Te1/1/17(P) Te2/1/17(P)

41 Po41(SU) LACP Te1/1/18(P) Te2/1/18(P)

42 Po42(SU) LACP Te1/1/19(P) Te2/1/19(P)

43 Po43(SU) LACP Te1/1/20(P) Te2/1/20(P)

44 Po44(SU) LACP Te1/1/21(P) Te2/1/21(P)

45 Po45(SD) LACP Te1/1/22(D) Te2/1/22(D)

91 Po91(SU) LACP Te1/1/24(P) Te2/1/24(P)

92 Po92(SU) LACP Te1/1/25(P) Te2/1/25(P)

93 Po93(SD) LACP Te1/1/26(D) Te2/1/26(D)

94 Po94(SD) LACP Te1/1/27(D) Te2/1/27(D)

AVID-CORE1-VSS(config-if-range)#

D.1.6 ENGINE 5 !! AND now the final engine Engine 5 AVID-CORE1-VSS(config-if-range)#int ran t1/1/6,t1/1/22,t2/1/6, t2/1/22

AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#do sh clock

*11:59:30.056 AST Wed Jul 19 2017

AVID-CORE1-VSS(config-if-range)#no shut

AVID-CORE1-VSS(config-if-range)#

*Jul 19 11:59:47.442: %EC-5-L3DONTBNDL2: Te1/1/6 suspended: LACP currently not enabled on the

remote port.

*Jul 19 11:59:55.577: %EC-5-L3DONTBNDL2: Te2/1/22 suspended: LACP currently not enabled on

the remote port.

*Jul 19 12:00:04.007: %EC-5-L3DONTBNDL2: Te2/1/6 suspended: LACP currently not enabled on the

remote port.

*Jul 19 12:00:04.280: %EC-5-L3DONTBNDL2: Te1/1/22 suspended: LACP currently not enabled on

the remote port.

AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#do sh etherchannel sum

Flags: D - down P - bundled in port-channel

I - stand-alone s - suspended

H - Hot-standby (LACP only)

R - Layer3 S - Layer2

U - in use f - failed to allocate aggregator

M - not in use, minimum links not met

u - unsuitable for bundling

w - waiting to be aggregated

d - default port

Number of channel-groups in use: 18

Number of aggregators: 18

Group Port-channel Protocol Ports

------+-------------+-----------+-----------------------------------------------

1 Po1(SU) - Te1/1/15(P) Te1/1/16(P) Te1/1/31(P)

Te1/1/32(P)

2 Po2(SU) - Te2/1/15(P) Te2/1/16(P) Te2/1/31(P)

Te2/1/32(P)

10 Po10(SU) LACP Te1/1/1(P) Te2/1/1(P)

11 Po11(SU) LACP Te1/1/2(P) Te2/1/2(P)

12 Po12(SU) LACP Te1/1/3(P) Te2/1/3(P)

13 Po13(SU) LACP Te1/1/4(P) Te2/1/4(P)

14 Po14(SU) LACP Te1/1/5(P) Te2/1/5(P)

15 Po15(SD) LACP Te1/1/6(s) Te2/1/6(s)

40 Po40(SU) LACP Te1/1/17(P) Te2/1/17(P)

41 Po41(SU) LACP Te1/1/18(P) Te2/1/18(P)

42 Po42(SU) LACP Te1/1/19(P) Te2/1/19(P)

43 Po43(SU) LACP Te1/1/20(P) Te2/1/20(P)

44 Po44(SU) LACP Te1/1/21(P) Te2/1/21(P)

45 Po45(SD) LACP Te1/1/22(s) Te2/1/22(s)

91 Po91(SU) LACP Te1/1/24(P) Te2/1/24(P)

92 Po92(SU) LACP Te1/1/25(P) Te2/1/25(P)

93 Po93(SD) LACP Te1/1/26(D) Te2/1/26(D)

94 Po94(SD) LACP Te1/1/27(D) Te2/1/27(D)

AVID-CORE1-VSS(config-if-range)#do sh clock

*12:00:23.799 AST Wed Jul 19 2017

AVID-CORE1-VSS(config-if-range)#

*Jul 19 12:01:46.936: %EC-5-L3DONTBNDL2: Te2/1/22 suspended: LACP currently not enabled on

the remote port.

*Jul 19 12:01:52.179: %EC-5-L3DONTBNDL2: Te2/1/6 suspended: LACP currently not enabled on the

remote port.

*Jul 19 12:02:52.188: %EC-5-BUNDLE: Interface Te1/1/22 joined port-channel Po45

*Jul 19 12:02:52.340: %EC-5-BUNDLE: Interface Te2/1/22 joined port-channel Po45

*Jul 19 12:02:52.306: %EC-5-BUNDLE: STANDBY:Interface Te1/1/22 joined port-channel Po45

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 218 of 242

*Jul 19 12:02:52.455: %EC-5-BUNDLE: STANDBY:Interface Te2/1/22 joined port-channel Po45

AVID-CORE1-VSS(config-if-range)#

AVID-CORE1-VSS(config-if-range)#do sh etherchannel sum

Flags: D - down P - bundled in port-channel

I - stand-alone s - suspended

H - Hot-standby (LACP only)

R - Layer3 S - Layer2

U - in use f - failed to allocate aggregator

M - not in use, minimum links not met

u - unsuitable for bundling

w - waiting to be aggregated

d - default port

Number of channel-groups in use: 18

Number of aggregators: 18

Group Port-channel Protocol Ports

------+-------------+-----------+-----------------------------------------------

1 Po1(SU) - Te1/1/15(P) Te1/1/16(P) Te1/1/31(P)

Te1/1/32(P)

2 Po2(SU) - Te2/1/15(P) Te2/1/16(P) Te2/1/31(P)

Te2/1/32(P)

10 Po10(SU) LACP Te1/1/1(P) Te2/1/1(P)

11 Po11(SU) LACP Te1/1/2(P) Te2/1/2(P)

12 Po12(SU) LACP Te1/1/3(P) Te2/1/3(P)

13 Po13(SU) LACP Te1/1/4(P) Te2/1/4(P)

14 Po14(SU) LACP Te1/1/5(P) Te2/1/5(P)

15 Po15(SD) LACP Te1/1/6(D) Te2/1/6(D)

40 Po40(SU) LACP Te1/1/17(P) Te2/1/17(P)

41 Po41(SU) LACP Te1/1/18(P) Te2/1/18(P)

42 Po42(SU) LACP Te1/1/19(P) Te2/1/19(P)

43 Po43(SU) LACP Te1/1/20(P) Te2/1/20(P)

44 Po44(SU) LACP Te1/1/21(P) Te2/1/21(P)

45 Po45(SU) LACP Te1/1/22(P) Te2/1/22(P)

91 Po91(SU) LACP Te1/1/24(P) Te2/1/24(P)

92 Po92(SU) LACP Te1/1/25(P) Te2/1/25(P)

93 Po93(SD) LACP Te1/1/26(D) Te2/1/26(D)

94 Po94(SD) LACP Te1/1/27(D) Te2/1/27(D)

AVID-CORE1-VSS(config-if-range)#

!! THEN SAVE THE CONFIG, which is copied to the other VSS member. AVID-CORE1-VSS(config-if-range)#do wr

Building configuration...

Compressed configuration from 20872 bytes to 7338 bytes[OK]

AVID-CORE1-VSS(config-if-range)#

*Jul 19 12:03:41.450: %C4K_REDUNDANCY-5-CONFIGSYNC: The private-config has been successfully

synchronized to the standby supervisor

*Jul 19 12:03:41.736: %C4K_REDUNDANCY-5-CONFIGSYNC: The startup-config has been successfully

synchronized to the standby supervisor

~SECTION END~

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 219 of 242

Appendix E – Useful articles In no particular order or vendor preference, things I found while looking up other stuff or for related information

E.1 Cabling, Optics and Transceivers MELLANOX BLOG http://www.mellanox.com/blog/author/bradsmith/ Part I of Three Part Blog Series on Cables & Transceivers http://www.mellanox.com/blog/2016/10/16-ways-linkx-dac-cables-are-breaking-out-all-over-servers-and-storage/ This blog is Part 2 in a 3-part series on Mellanox’s high-speed interconnect products. AOCs – Active Optical Cables Why are 2 transceivers and fibers priced less than one connectorized transceiver http://www.mellanox.com/blog/2016/12/aocs-active-optical-cables-why-are-2-transceivers-and-fibers-priced-less-than-one-connectorized-transceiver/ NEVER FOUND PART 3of 3 Do You Know about Active Optical Cable (AOC Cable)? http://www.cables-solutions.com/do-you-know-about-active-optical-cable-aoc.html Active Optical Cable (AOC) – Rising Star of Telecommunications & Datacom Transceiver Markets https://community.fs.com/blog/active-optical-cable-aoc-rising-star-of-telecommunications-datacom-transceiver-markets.html ACTIVE OPTICAL CABLE (AOC) EXPLAINED IN DETAILS ! https://www.fiberoptics4sale.com/blogs/archive-posts/95047430-active-optical-cable-aoc-explained-in-details.

Avid does NOT test any AoC products (active over optical). While AoC might work between a Switch and relatively recent NIC (happily passing NEXIS traffic) , you are likely to encounter problems if this is connected directly to a NEXIS engine, the Mellanox CX3 adapter (an old legacy 1-/40G device in Mellanox terms because there are so many newer 10/25G products) does not support any AoC vendor that I am aware of. AoC is a great, reduced cost short haul fibre method with “sealed” transceivers at each end and hence fixed lengths up to 150m (for MMF variants). However just like TWINAX (that was not supported with ISIS7x00) the firmware on the terminating devices need to support AoC too.

QSFP-DD vs OSFP: The Wave of the Future 400G Transceiver http://www.fiber-optic-transceiver-module.com/qsfp-dd-vs-osfp-the-wave-of-the-future-400g-transceiver.html OSFP interconnect: what is it? https://www.connectortips.com/osfp-interconnect-consortium/

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 220 of 242

E.2 CISCO FABRIC INTERCONNECT TUTORIAL Cisco Fabric Interconnect looks (physically) like a network switch, but they are a very different animal that server an important purpose, reduce wiring sprawl with UCS blade servers. UCS HARDWARE TUTORAL SEVERAL LESSONS IN SERIES LESSON 1 UCS HARDWARE https://www.youtube.com/watch?v=hTZj0_H0kSA LESSON 2 UCS Chassis Discovery https://www.youtube.com/watch?v=1F4p7GF4Rks LESSON 3 UCS LAN Uplinks https://www.youtube.com/watch?v=nKTp02s9Asc

E.3 Packet Life and CLOUDSHARK This website (https://packetlife.net/captures/) has Wireshark captures for reviewing online in CLOUDSHARK. A great tool for looking into the weeds of routing protocols messages or multicast messages a learning what is not discussed in sufficient depth in most books and articles. Thanks to Stretch!

E.4 Articles on Loopback interfaces Cisco Loopback Interfaces Tutorial (EIGRP) https://www.flackbox.com/cisco-loopback-interfaces Understanding the Loopback Interface & Loopback Address (OSPF) https://study-ccna.com/loopback-interface-loopback-address/ OSPF Advertising Loopback Interface https://www.n-study.com/en/ospf-detail/ospf-advertising-loopback/

E.5 MULTICAST ARTICLES & TUTORIALS RATINGS ** VERY GOOD * GOOD + OK - POOR All approx 1 hour but incredibly detailed yet easy to comprehend 17AUG21 **Lecture 1 - IP Multicast Basics and Addressing Nic Bhasin https://www.youtube.com/watch?v=fRiOOWJDcK8&ab_channel=DecodingPackets **Lecture 2 - IP Multicast Routers and Routing Protocols https://www.youtube.com/watch?v=Wao6FHI8rgE&ab_channel=DecodingPackets **Lecture 3 - IP Multicast Receiver Signaling with IGMPv1 and IGMPv2 https://www.youtube.com/watch?v=BC8MfzMSRhY&ab_channel=DecodingPackets **Lecture 4 - IP Multicast Receiver Signaling with IGMPv3 https://www.youtube.com/watch?v=Sgppv6HRFSs&t=4s&ab_channel=DecodingPackets **Lecture 5 - IP Multicast Source Signaling

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 221 of 242

https://www.youtube.com/watch?v=HZdXpyMbq20&ab_channel=DecodingPackets **Lecture 6 - Introduction to PIM, PIM Dense Mode Deep Dive https://www.youtube.com/watch?v=9sNOiLjyPnk&t=9s&ab_channel=DecodingPackets **Lecture 7 - Introduction to PIM Sparse Mode https://www.youtube.com/watch?v=QaNFiRJiTNM&t=2s&ab_channel=DecodingPackets **Lecture 8 - Advanced PIM Sparse Mode Deep Dive Part 1 https://www.youtube.com/watch?v=WQvbTxDmXMc&t=2s&ab_channel=DecodingPackets **Lecture 9 - Advanced PIM Sparse Mode Deep Dive Part 2 https://www.youtube.com/watch?v=bMVbDiwN7UY&ab_channel=DecodingPackets **Lecture 10 - Advanced PIM Sparse Mode Deep Dive Part 3 https://www.youtube.com/watch?v=SCVDPlmsl4g&ab_channel=DecodingPackets **Demo 0 - Topology Information for Multicast Lecture Series https://www.youtube.com/watch?v=QJfN0aHgF_I&ab_channel=DecodingPackets **Demo 1.1 - IGMPv2 on IOS Routers https://www.youtube.com/watch?v=-YR3PqRqDak&ab_channel=DecodingPackets **Demo 2 - IGMPv3 on IOS and Junos Routers https://www.youtube.com/watch?v=qfiiHcG2QXQ&ab_channel=DecodingPackets DONE **Demo 3.1 - PIM Dense Mode on IOS Routers https://www.youtube.com/watch?v=J6vc59BKeIg&ab_channel=DecodingPackets NOT REQUIRED IN MODERN NETWWORKS **Demo 4.1 - PIM Sparse Mode on IOS Routers Part 1 https://www.youtube.com/watch?v=nx2fpcJ2QC0&ab_channel=DecodingPackets **Demo 4.2 - PIM Sparse Mode on IOS Routers Part 2 https://www.youtube.com/watch?v=zZpQ-8hx5Lc&ab_channel=DecodingPackets **IGMP Snooping and VLC player KeithBarker https://www.youtube.com/watch?v=5Ovh9dUsAWU&ab_channel=KeithBarker **IGMP - Internet Group Management Protocol Tall Paul Tech

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 222 of 242

https://www.youtube.com/watch?v=MaTkt-wNHRg&ab_channel=TallPaulTech

E.6 SDWAN ARTICLES & TUTORIALS RATINGS ** VERY GOOD * GOOD + OK - POOR --- SD WAN BASICS ---- *Software-Defined WAN (SD-WAN) - Explained 227,489 views•14 Nov 2017 https://www.youtube.com/watch?v=u2N7q1w26Mg&ab_channel=Riverbed **What is SD-WAN? 4m 137,594 views•17 Jun 2019 https://www.youtube.com/watch?v=5Tv-Lf8_3NM&ab_channel=SilverPeak THIS LEADS ONTO OTHER SHORT VIDEOS a GOOD TUTORIAL with SIX SHORT SEGMENTS * What is SD-WAN and why do you need it? Quick Explainer Video DELL! 86,510 views•18 Oct 2019 13 min https://www.youtube.com/watch?v=OF997v3H2i4&ab_channel=Dell THIS LEADS ONTO OTHER SHORT VIDEOS *Fundamentals of SD-WAN 12min 88,312 views•11 Feb 2020 https://www.youtube.com/watch?v=cos4ujj80iI&ab_channel=KevinWallaceTraining%2CLLC

E.7 AZURE TUTORIALS & ARTICLES RATINGS ** VERY GOOD * GOOD + OK - POOR https://docs.microsoft.com/en-us/azure/virtual-wan/virtual-wan-about What is Azure Virtual WAN? --- EXPRESS ROUTE --- +Windows Azure ExpressRoute Overview John Savill 31,537 views•17 Mar 2014 7m https://www.youtube.com/watch?v=rYqL5-nNpjc OLD BUT A GOOD TASTER, LOTS HAS CHANGED IN 7 YEARS (SINCE ER- PREVIEW) http://msdn.microsoft.com/library/windowsazure/dn606309.aspx *ExpressRoute Deep Dive John Savill 19,476 views•16 Apr 2020 79m https://www.youtube.com/watch?v=oevwZZ1YFS0

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 223 of 242

2018 *Azure ExpressRoute demystified | whiteboarding session Marc Kean Stephane Budo 17,208 views•4 Aug 2018 31m https://www.youtube.com/watch?v=RkuZD8y2JnM&t=1s *Azure ExpressRoute demystified (part 2) | whiteboarding session Marc Kean Stephane Budo https://www.youtube.com/watch?v=6U-Mheb6Qnw 4,032 views•29 Oct 2018 30m *Azure ExpressRoute demystified (part 3) | whiteboarding session Marc Kean https://www.youtube.com/watch?v=P9qsA0EOFvU 1,350 views•19 Feb 2020 29m also see https://aka.ms/VPN-over-ER https://docs.microsoft.com/en-us/azure/expressroute/expressroute-config-samples-routing *ExpressRoute: What is it, and why should I use it? Billy Clay Myers 7,059 views•21 Jan 2018 26m https://www.youtube.com/watch?v=2mNYLVUvDj8 * 2016-09-26 - Azure Networking, From Rookie to Expert 30,713 views•27 Sept 2016 56m https://www.youtube.com/watch?v=0FN-rlLUtj4 *https://azure.microsoft.com/en-us/documentation/videos/azurecon-2015-expressroute-for-experts/ xx Mark Russinovich on Software defined networking in azure xx https://www.youtube.com/watch?v=RffHFlhg5Sc + AzureTalk | Azure Networking | Session 1 Niraj Kumar 54,651 views•2 Jul 2017 78m https://www.youtube.com/watch?v=yel-ssaoVXQ + AzureTalk: Azure Networking Part 2 Niraj Kumar 16,298 views•10 Jul 2017 67m https://www.youtube.com/watch?v=OBpK3tP30hk !! POWERSHELL COMMANDS * AzureTalk: Azure Networking Part 3, ExpressRoute Niraj Kumar 16,455 views•15 Jul 2017 71m https://www.youtube.com/watch?v=miGhu_pPwQQ

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 224 of 242

- AzureTalk-Networking Part 4: Azure DNS, Application gateway, Traffic Manager, Load balancer Niraj Kumar 15,274 views•31 Jul 2017 106m https://www.youtube.com/watch?v=ezIsW_6GcVg -POOR AUDIO AND LONG WINDED * THIS GUY IS VERY GOOD Generally has 10-20 Minute sessions ** Azure Traffic Manager Tutorial | DNS load balancer intro Adam Marczak•2 Jan 2020 21m https://www.youtube.com/watch?v=aPNa7Axulhg **Azure Load Balancer Tutorial Adam Marczak•9 Jan 2020 20m https://www.youtube.com/watch?v=T7XU6Lz8lJw ** Azure Storage Tutorial | Introduction to Blob, Queue, Table & File Share Adam Marczak •5 Aug 2019 23m https://www.youtube.com/watch?v=UzTtastcBsk * What is Azure Application Gateway? | How to Deploy Application Gateway Adam Gordon ITProTV views•7 Nov 2020 17m https://www.youtube.com/watch?v=n9uHSHO25cE https://www.youtube.com/watch?v=Ma7VAQE7ga4&ab_channel=AdamMarczak-AzureforEveryone Azure Active Directory (AD, AAD) Tutorial | Identity and Access Management Service Adam Marczak - Azure for Everyone views•23 Jun 2020 31m marczak.io/az-900#ep01 Adam Marczak AZ-900 series has 39 episodes as at APRIL 2021 AZ-900 Episode 1 | Cloud Computing and Vocabulary | Microsoft Azure Fundamentals Full Course Adam Marczak •7 Jul 2020 https://www.youtube.com/watch?v=Pt9LelJ0fL0 marczak.io/az-900#ep01 NO ADVERTS!! HOORAY https://www.youtube.com/watch?v=NPEsD6n9A_I&ab_channel=AdamMarczak-AzureforEveryone ** Episode 0 AZ-900 | Microsoft Azure Fundamentals Full Course Preview 7m ** AZ-900 Episode 1 | Cloud Computing and Vocabulary | 7 Jul 2020 | 10m ** AZ-900 Episode 2 | Principle of economies of scale | 7 Jul 2020 | 4m ** AZ-900 Episode 3 | CapEx vs OpEx and their differences | 7 Jul 2020 | 5m ** AZ-900 Episode 4 | Consumption-based Model | 14 Jul 2020 | 6m

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 225 of 242

** AZ-900 Episode 5 | IaaS vs PaaS vs SaaS cloud service models | 14 Jul 2020 | 8m Episodes 1-5 33 minutes ** AZ-900 Episode 6 | Public, Private & Hybrid cloud deployment models | 14 Jul 2020 | 5m ** AZ-900 Episode 7 | Geographies, Regions & Availability Zones | 30 Jul 2020 | 15m ** AZ-900 Episode 8 | Resources, Resource Groups & Resource Manager | 3 Aug 2020 | 13m ** AZ-900 Episode 9 | Compute Services : VMs, VM Scale Set, App Service, Functions, ACI, AKS | 14 Aug 2020 | 26m ** AZ-900 Episode 10 | Networking Services : Virtual Network, VPN Gateway, CDN, Load Balancer, App GW| 18 Aug 2020| 17m Episodes 6-10 76minutes ** AZ-900 Episode 11 | Azure Storage Services : Blob, Queue, Table, Files, Disk and Storage Tiers | 26 Aug 2020 | 19m * AZ-900 Episode 12 | Database Services : Cosmos DB, SQL Database, Db for MySQL & PostgreSQL | 1 Sept 2020 | 13m *AZ-900 Episode 13 | Azure Marketplace| 9 Sept 2020 | 6m *AZ-900 Episode 14 | Azure IoT Services : IoT Hub, IoT Central, Azure Sphere | 10 Sept 2020 | 10m *AZ-900 Episode 15 | Azure Big Data & Analytics Services : Synapse, HDInsight, Databricks | 16 Sept 2020 | 10m Episodes 11-15 58 minutes * AZ-900 Episode 16 | Azure Artificial Intelligence (AI) Services : Machine Learning Studio & Service | 21 Sept 2020 | 8m * AZ-900 Episode 17 | Azure Serverless Computing Services : Functions, Logic Apps, Event Grid | 23 Sept 2020 | 10m ** AZ-900 Episode 18 | Azure DevOps Solutions : Azure DevOps, DevTest Labs | 29 Sept 2020 | 11m ** AZ-900 Episode 19 | Azure Tools : Azure Portal, CLI, PowerShell & Cloud Shell | 30 Sept 2020 | 10m ** AZ-900 Episode 20 | Azure Advisor | 1 Oct 2020 | 6m Episodes 16-20 45m (3.5 "linear hours" so far) BEGIN MODULE 3 ** AZ-900 Episode 21 | Azure Security Groups : Network and Application Security Groups (NSG, ASG) | 5 Oct 2020 | 9m ** AZ-900 Episode 22 | User-defined Routes (UDR) with Route Tables | Oct 2020 | 6m ** AZ-900 Episode 23 | Azure Firewall | 9 Oct 2020 | 6m ** AZ-900 Episode 24 | Azure DDoS Protection : Distributed Denial of Service | 9 Oct 2020 |5m ** AZ-900 Episode 25 | Azure Identity Services : Authentication, Authorization & Active Directory (AD) | 13 Oct 2020 | 12m Episodes 21-25 38m * AZ-900 Episode 26 | Azure Security Center | 20 Oct 2020 | 11 m ** AZ-900 Episode 27 | Azure Key Vault : Secret, Key and Certificate Management | 21 Oct 2020 | 9m * AZ-900 Episode 28 | Azure Role-based Access Control (RBAC) | 6 Nov 2020 | 14m

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 226 of 242

** AZ-900 Episode 29 | Azure Resource Locks | 11 Nov 2020 | 8m ** AZ-900 Episode 30 | Azure Resource Tags | 17 Nov 2020 |13m Episodes 26-30 55m * AZ-900 Episode 31 | Azure Policy | 9 Dec 2020 | 15m * AZ-900 Episode 32 | Azure Blueprints | 18 Dec 2020 | 10m * AZ-900 Episode 33 | Cloud Adoption Framework for Azure | 14 Jan 2021 |23m + AZ-900 Episode 34 | Core tenets of Security, Privacy, Compliance (Trust Center, DPA, OST, and more.) | 29 Jan 2021 | 16m * AZ-900 Episode 35 | Cost Affecting Factors | 5 Feb 2021 | 11m * AZ-900 Episode 36 | Cost Reduction Methods, Reservations, Hybrid benefit, Spot VM, Pricing & TCO | 23 Feb 2021 |16m * AZ-900 Episode 37 | Azure Cost Management | 12 Mar 2021 | 10m ** AZ-900 Episode 38 | SLA and Composite SLA in Azure | 31 Mar 2021 | 15m ** AZ-900 Episode 39 | Service Lifecycle in Azure : Public Preview and General Availability | 23 Apr 2021 | 7m Episodes 36-39 55m https://docs.microsoft.com/en-us/learn/certifications/exams/az-900 https://www.youtube.com/watch?v=NKEFWyqJ5XA&ab_channel=freeCodeCamp.org Microsoft Azure Fundamentals Certification Course (AZ-900) - Pass the exam in 3 hours! freeCodeCamp.org •17 Jun 2020 Andrew Brown -Exam Pro, BUT IT IS 3HR 10MIN Annoying voice though. AZ-900 | Microsoft Azure Virtual Training Day Fundamentals - Part 1 [CC] 9,020 views•17 Dec 2020 MATT HESTER 3hr 08min https://www.youtube.com/watch?v=oDqaJlNd5B4&ab_channel=DineshRaju https://www.youtube.com/watch?v=efizFa8IJ_Q&ab_channel=DineshRaju AZ-900 | Microsoft Azure Virtual Training Day Fundamentals - Part 2 [CC] 3,945 views•18 Dec 2020 MATT HESTER 2hr 32min --- JOHN SAVILL ---- JOHN SAVILL, is GOOD STUFF https://www.youtube.com/watch?v=7rzawA--r20 Azure Virtual Network Overview 28,451 views•4 Feb 2020 Network Security Groups in Azure Virtual Networks John Savill Apr 16, 2015

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 227 of 242

https://www.youtube.com/watch?v=9qG-5Hzx-8w LONG SESSIONS! ** Azure Master Class Part 1 - Cloud Foundation John Savill•8 Sept 2020 | 51m https://www.youtube.com/watch?v=aHJe0qBqwmk ** Azure Master Class Part 2 - Identity John Savill•15 Sept 2020 | 105m https://www.youtube.com/watch?v=Jd3IzN9x2as ** Azure Master Class Part 3 - Governance John Savill•22 Sept 2020 | 91m https://www.youtube.com/watch?v=cIh_Nfl67T0 ** Azure Master Class Part 4 - Resiliency John Savill•29 Sept 2020 | 103m https://www.youtube.com/watch?v=zLMXu4rtlEk ** Azure Master Class Part 5 - Storage John Savill•6 Oct 2020 | 119m https://www.youtube.com/watch?v=ZNuzmUKt6IE ** Azure Master Class Part 6 - Networking John Savill•13 Oct 2020 | 108m https://www.youtube.com/watch?v=K8ePZdLfU7M ** Azure Master Class Part 7 - VMs and VMSS John Savill•Oct 20, 2020 | 122m https://www.youtube.com/watch?v=LLhzCgIJMdo + Azure Master Class Part 8 - Application Services John Savill•Oct 27, 2020 | 119m https://www.youtube.com/watch?v=_E73_SQN8ZU * Azure Master Class Part 9 - Monitoring and Security John Savill•Nov 3, 2020 | 95 m https://www.youtube.com/watch?v=hTS8jXEX_88 Azure Master Class Part 10 - Database John Savill•Nov 10, 2020 | 118m https://www.youtube.com/watch?v=Af8s5uaMLgY Azure Master Class Part 11 - Infrastructure as Code, GIT and DevOps

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 228 of 242

John Savill•Nov 17, 2020 | 128m https://www.youtube.com/watch?v=wR92fLyrW6I Azure Infrastructure State of the Union 2021 John Savill•Jan 5, 2021 https://www.youtube.com/watch?v=acOzfw3z0Rc Advanced networking best practices with Azure ExpressRoute BRK3172 Marc Kean https://www.youtube.com/watch?v=0wsQrP6cAB8 --- OTHER GOOD STUFF ---- Azure Bastion: Private and fully managed RDP and SSH access to your virtual machines https://azure.microsoft.com/en-gb/services/azure-bastion/ ** GOOD SHORT VIDEO https://docs.microsoft.com/en-us/azure/bastion/bastion-overview --- AWS & AZURE & GXP --- Comparing Dedicated Cloud Connectivity Options An overview of AWS Direct Connect, Microsoft Azure ExpressRoute, and Google Cloud Dedicated Interconnect. https://www.networkcomputing.com/networking/comparing-dedicated-cloud-connectivity-options --- AZURE WAN ---- * https://www.youtube.com/watch?v=f-GyAURZWzg&ab_channel=JohnSavill Azure Virtual WAN Overview 9,249 views•25 Jul 2020 18m + Architect hybrid networking with Azure Virtual WAN and SD-WAN 4,331 views•10 Nov 2020 26m (slow down voice to 0.75) https://www.youtube.com/watch?v=2g-_empU0GU&ab_channel=MicrosoftAzure *An Introduction to Azure Virtual WAN 46m 1,162 views•6 Nov 2020 https://www.youtube.com/watch?v=7C_6TYz6q8g&ab_channel=AidanFinn --- EXAM GOODIES ---- [New] Azure Fundamentals - AZ-900 - Real Exam Questions for 2021 - Part 6 (tricks & explanation) T3P•2 Feb 2021 https://www.youtube.com/watch?v=acRyNsCvZ8s https://www.youtube.com/watch?v=kikcPTxcYCA&ab_channel=CloudGuru Azure Foundation - AZ-900 - Real Exam Questions - Part -1 (with explanations)

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 229 of 242

27m 64,466 views•31 Oct 2020 https://www.youtube.com/watch?v=vVSVX-86Qxs&ab_channel=CloudGuru Azure 900 certification - Real Exam Questions (Part 2) 19,643 views•1 Nov 2020

E.8 KUBERNETES TUTORIALS & ARTICLES Kubernetes Concepts Explained in 9 minutes! 538,980 views•31 Oct 2019 https://www.youtube.com/watch?v=QJ4fODH6DXI What is Kubernetes | Kubernetes explained in 15 mins 197,519 views•20 Dec 2019 https://www.youtube.com/watch?v=VnvRFRk_51k The Illustrated Children's Guide to Kubernetes 476,467 views•9 Jun 2016 https://www.youtube.com/watch?v=4ht22ReBjno Kubernetes Architecture Simplified | K8s Explained in 10 Minutes 208,432 views•27 Apr 2019 https://www.youtube.com/watch?v=8C_SCDbUJTg Docker for Beginners: Full Free Course! 590,806 views•9 Aug 2019 https://www.youtube.com/watch?v=zJ6WbK9zFpI Docker For Beginners: From Docker Desktop to Deployment 330,698 views•12 Apr 2020 https://www.youtube.com/watch?v=i7ABlHngi1Q Kubernetes is dropping Docker support - What does it mean for YOU? 316,377 views•10 Dec 2020 https://www.youtube.com/watch?v=7KUdmFyefSA Kubernetes is dropping Docker support?! 174,691 views. •2 Dec 2020 https://www.youtube.com/watch?v=0oVDPf8zPS0 Azure Kubernetes Services (AKS) Overview 16,593 views•7 Jun 2020 John Savill

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 230 of 242

https://www.youtube.com/watch?v=c4nTKMU6fBU

Appendix F – Which Cisco Operating system to use? The information here for CATALYST was imported for NETREQS V1.x, so it might seem quite old, but the rationale still applies, as later versions exist since the time of writing (approx. spring 2016). It has now been extended to include NXOS in section F.2. Similar principles can be applied to other vendors such as Arista, Dell, and Juniper. Many of the principles apply equally well to NXOS and the minimum recommended version is listed elsewhere in this document. Avid does not routinely test any/new IOS or NXOS, but I list ones which I know have given Avid problems, and hence this should be avoided.

F.1 Catalyst

F.1.2 Which version of (Cisco) IOS is supported? With regard to the switches that Avid supplies, there are no special commands that require specific IOS versions. Avid does not routinely test newer versions of IOS. When Avid tests a switch, the version supplied will be the minimum software version supported. This “minimum version” principle applies to both QUALIFIED switches and APPROVED switches. Specific hardware options in a vendor switch family may well dictate software versions. In rare situations when a network vendor rectifies a specific DEFECT, then an upgrade may be required or recommended.

Note: this principle applies to Foundry/Brocade & Dell/Force10 products, but the software names are different to IoS.

There are rare situations when in extended deployment (not direct connect to ISIS with vanilla configuration), with special features that certain commands are required. One example of this is with the Foundry and IEEE802.1q trunks on 10G links that is described elsewhere in this document.

Minimum s/w versions are described in The Avid ISIS 7000 Ethernet Switch Reference Guide available at: http://resources.avid.com/SupportFiles/attach/AvidISIS/AvidNetworkSwitchGuide_v4.7.3_Rev_F.pdf

NOTE: C4900M and C4948E and C4500E/SUP6 should avoid the s/w version below: 15.1(1)SG (APR 2012) and 15.1(2)SG (NOV2012) These versions have a bug in a new feature called Bidirectional Forwarding Detection, which can drop ISIS packets.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 231 of 242

The aforementioned bug is corrected in: ENTERPRISE SERVICES W/O CRYPTO cat4500e-entservices-mz.151-2.SG1.bin 24-JUL-2013 IP BASE W/O CRYPTO cat4500e-ipbase-mz.151-2.SG1.bin 24-JUL-2013 http://software.cisco.com/download/release.html?mdfid=283027810&flowid=3592&softwareid=280805680&release=15.1.2-SG1&relind=AVAILABLE&rellifecycle=ED&reltype=latest

C4900M, C4948E, C4948-10GE and C4500E devices using 12.2.x IOS will not exhibit the BFD problems and do not need to be upgraded.

F.1.2.1 What is the minimum software version recommended? As mention in Section 1.3.2/Above Avid does not test all the IOS versions, this would be a massive and untenable undertaking. When projects purchase their own product, I am often asked what I recommend as a suitable software version. Well, the answer is “IT DEPENDS….”, which at first sight is unhelpful. Initially understand that for Avid solutions the additional features in the new release are extremely unlikely to be needed by the Avid applications, so the major version and point version may be of little relevance, but the maintenance version might be critical in terms of avoiding bugs. Secondly consider that when you are reading this content and when it was written will have significant bearing on any suggestion of version number, as they keep advancing with all vendors. Also, there may be corporate policies of the destination deployment that will restrict the choices that can be made. Using cisco and an example see the screen shot below from their website

from http://www.cisco.com/c/en/us/products/collateral/ios-nx-os-software/ios-xr-software/product_bulletin_c25-478699.html

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 232 of 242

So, the key thing when looking at release notes is to pick a recent version, that is above the maintenance version and not too new and not too old, and that has a long maintenance window. The h So, I WOULD ALWAYS AVOID a version that was X.0.0, and one that was X.Y.0 The hypothetical version 8 and 9 is used below for explanation, and we will assume that the minimum version Avid was 7.8.9 and that was 5 years from the reading date Hence lest us consider: Hypothetical Version 8 introduced 3 years from the reading date 8.0.x = AVOID 8.1.0 = AVOID 8.1.2 = GOOD 8.1.3 = GOOD 8.2.0 = AVOID 8.2.1 = GOOD 8.2.2 = GOOD 8.3.0 = AVOID 8.3.1 = GOOD 8.3.3 = GOOD 8.3.4 = GOOD – LAST VERSION BEFORE V9 Hypothetical Version 9 introduced 1 year from the reading date 9.0.x = AVOID 9.1.0 = AVOID 9.1.1 = GOOD 9.1.2 = GOOD 9.2.0 = AVOID LATEST VERSION Generally, I will also avoid anything that is too new. I like it to have at least 3 months in the field. And I would avoid anything new major release for 6 months. But if the “latest” version is older than 9 months, as might be the case on more mature (or end of sale) products then it should be a safe choice. So again, to use hypothetical situation of the 9.2.x thread was release in 1/JAN/2001 I would not even consider is until 1/JUL/2001 and would want 9.1.1 minimum F.1.2.2 Which IOS should I use on C4948E/C4900M? First read all of section 1.3.2 above because it has a bearing on the suggestions below. Also consider version mapping with the C45xx products below and they versions should ideally be equivalents when the products are mixed (which will frequently be the reality).

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 233 of 242

C4500-X /C4500E SUP7/8

First publish dates

C4900M/C4948E

First publish dates

3.3.0

First Published: 16-APR-2012

15.1.1

First Published: 16-APR-2012

3.4.1

First Published: 24-JUL-2013

15.1.2

First Published: 24-JUL-2013

3.5.1

First Published: 26-NOV-2013

15.2.1E1

First Published: 26-NOV-2013

3.6.0

First Published: 27-JUN-2014

15.2.2 E

First Published: 27-JUN-2014

3.7.0

First Published: 10-DEC-2014

15.2.3 ED

First Published: 10-DEC-2014

3.8.xE

First Published: 02-OCT-2015

15.2.4 ED

First Published: 02-OCT-2015

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 234 of 242

Avid does not MANDATE the version beyond the MINIMUM tested and specific version to avoid as listed by Avid or Cisco deprecation. At the time of writing this section [APRIL2016], below is the information from Cisco http://www.cisco.com/c/en/us/support/switches/catalyst-4900-series-switches/products-release-notes-list.html

I would be considering IOS- 15.2(3)E2 or 15.2(2)E4, the most recent update for them are 2 months old (or more) and the base software has a maturity level that in comforting. IOS-15.2(4)E was first published in First Published: October 1, 2015 and Last Updated: January 29, 2016, so this new kid on the block is probably too young for my preferences, the minimum version Avid supports is 12.2.(46) and the latest 12.2.(54) version is—AUG 2014 so this would be suitable too. BUT, by the time you read this, in 4 weeks, 3 months or 2 years on (you get the gist I hope), the paragraphs/screenshots immediately above will almost certainly be superseded by newer information. The point is to apply the principles.

Also be aware that some upgrades from older version might need a ROMMON upgrade too, if in doubt set up a TFTP boot to see if the desired code will RUN before doing the REAL upgrades into NVRAM via TFTP.

Cisco Catalyst C4500E EoS announcement 31 OCT 19 https://www.cisco.com/c/en/us/products/collateral/switches/catalyst-4500-series-switches/eos-eol-notice-c51-743088.html

F.1.2.3 Which IOS-XE should I use on C4500-X?

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 235 of 242

First read all of section 1.3.2 above because it has a bearing on the suggestions below. Also consider version mapping with the C49xx products below and they versions should ideally be equivalents when the products are mixed (which will frequently be the reality).

Avid does not MANDATE the version beyond the MINIMUM tested and specific version to avoid as listed by Avid or Cisco deprecation. At the time of writing this section [APRIL2016], below is the information from Cisco http://www.cisco.com/c/en/us/support/switches/catalyst-4500-x-series-switches/products-release-notes-list.html [STILL VALID FEB 2019]

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 236 of 242

I would be considering IOS-XE 3.7.x or 3.6.x, the most recent update for them are 2 months old and the software has a maturity level that in comforting. IOS-XE 3.8.x was first published in First Published: October 1, 2015 and Last Updated: April 25, 2016 So, this new kid on the block is probably too young for my preferences, the minimum version Avid supports is 3.4.1 and the latest 3.4.x version is IOS XE 3.4.7SG—Dec 07, 2015 so this would be suitable As for IOS-XE3.5 as has not been updated for almost 2 years. BUT, by the time you read this, in 4 weeks, 3 months or 2 years on (you get the gist I hope), the paragraphs/screenshots immediately above will almost certainly be superseded by newer information. The point is to apply the principles.

Also be aware that some upgrades from older version might need a ROMMON upgrade too, if in doubt set up a TFTP boot to see if the desired code will RUN before doing the REAL upgrades into NVRAM via TFTP.

F.1.3.2.4 Which IOS- should I use on C4948-10GE First read all of section 1.3.2 above because it has a bearing on the suggestions below. Also As the C4948 10GE has been end of sales since AUG 2013 and is approaching end of Vulnerability S/W support and has less than 2 years until end of HW support, this is a difficult question. The best advice is to replace with C4948E or C4500X (or both), but in many cases that cannot be done in the short term. As Avid no longer sells this device, and it only really likely to be used a “dumb” layer 2 switch with good buffers for ISIS clients, cascaded from a newer higher function switch, it is not possible to give comprehensive advise as for other currently sold products. Hence keeping it running as 12.2(25) EWA8 or 12.2.46 will be satisfactory for these duties. There are a small number of legacy sites with little need for 10G connections sites still using these old switches as a L3 Primary switch, which should really be considering a MAJOR upgrade as soon as possible rather than worry about how to upgrade a C4948-10GE IOS. The running version on IOS is sufficient to provide all the necessary software features needed by a currently running legacy ISIS implementation. Assuming that the C4948-10GE was supplied by Avid is will probably be 12.2(25) EWA8 and the highest that can go WITHOUT a ROMMON upgrade is 12.2(46). The technical documentation on release note for C4948-10GE and C4500-Classic (SUP5 and SUP2) is very complex.

Also be aware that some upgrades from older version might need a ROMMON upgrade too, if in doubt set up a TFTP boot to see if the desired code will RUN before doing the REAL upgrades into NVRAM via TFTP.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 237 of 242

F.2 NEXUS and NXOS – Which one to choose? The subject of switch firmware is a constantly moving target. There are minimum recommended versions, where we know of bugs to avoid. Avid does not routinely trawl NXOS release notes. When bugs impact customer systems there will inevitably be some write up in this document soon after. NXOS 7.x and NXOS 9.x are different software streams that offer different feature sets and licencing conditions.

F.2.1 Which version of (Cisco) NXOS is supported? With regard to the Nexus switches that Avid supply or recommend, there are no special commands that require specific IOS versions. Avid does not routinely test newer versions of NXOS. When Avid tests a switch, the version supplied will be the minimum software version supported. This “minimum version” principle applies to both QUALIFIED switches and APPROVED switches. Specific hardware options in a vendor switch family may well dictate software versions. In rare situations when a network vendor rectifies a specific DEFECT, then an upgrade may be required or recommended. As can be seen in NETREQS 2.x section 1.3.0 there are known versions to avoid and use newer versions than those affected. This will inevitably always be a moving target as new versions are introduced. Avid certainly does not need any of the features in 9.x that are not part of 7.x, hence each is equally suitable providing the minimum version required by Avid is used. There are many successfully deployed systems of both s/w streams. While I tend to avoid X.0 releases, this depends on the naming convention, on NXOS 7.x EVERYTHING is X.0, but there are 47 versions (at the time of counting) of 7.0(3)Ix. My general advice is to use one version below the latest, as more folks will have used it beforehand than the latest and any nasty bugs may already be known and on the worksheet for the forthcoming version. But if the “latest” version is older than 9 months, as might be the case on more mature (or end of sale) products then it should be a safe choice. Sometime bugs are specific hardware, for example 9.3(1) has a bug which impacts the 9336C when used with QSA (and certain ports only) which is fixed in 9.3(2). (see my NETREQS page 21)… but does not impact N93180YC. NXOS 9.x has the benefit of a longer life than NXOS 7.x, especially as NXOS 10.x is now released (Q1/21), and that is necessary for the FX3 series of Nexus 93000 family which can also operate in FEX mode. Release Notes for Cisco Nexus 9000 Series Switches in NX-OS Mode https://www.cisco.com/c/en/us/support/switches/nexus-9000-series-switches/products-release-notes-list.html This URL is a good place to see if any of the known/fixed issues in the most recent release will impact the choice of version. NXOS is halfway downs the pages after all the ACI release notes.

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 238 of 242

Appendix Z Full Revision history Note: Holder for search engines: The Flockenator, Stingerator/Stingrator and Nexirator are internal system modelling tools created by Avid for use by Internal Sales. NETREQS this word is here for search ENGINES

Revision history Note Version for this document number DOES NOT directly correlate to ISIS or Interplay Production version

Version, Name & DATE

Comment

Initial Issue V1.0 04 July 2007 David Shephard

24 Version issues See Appendix Z in NETREQA V1.23

Initial Issue V2.0 15 DEC 2018 David Shephard

Major reformatting, re-write and removal of ISIS and Interplay content to NEXIS & Media CEntral

Version, Name & Date

Comment

Initial Issue V1.0

04 July 2007 David Shephard

V1.23 15 DEC 2017 David Shephard 340 Pages (from 324) FINAL VERSION of V1.x V2.x for NEXIS and MEDIA CENTRAL COMING VERY SOON

UPDATE & Restructure SECTION 11 for move to NETREQS V2 ADD 12.0 Network Designs for NEXIS (OLD SECTION 12 becomes SECTION 13) UPDATE (and correct typo) 1.4.19.2 New product naming for Nexus 6000 family UPDATE 1.5.7.3 Interim testing Nexus 93000 UPDATE 1.5.4 Cisco Nexus 5500/5000 ADD 11.2 Architecturally Capable Network switches (similar content at the beginning of section 1.4 and 1.5)

V2.0 15 DEC 2017 David Shephard 79 pages (from 340 in V1.23)

Restructure documents and remove legacy ISIS and Interplay information, which remains available in V1.23 Section 11 in V1.23 is section 1 in V2.0 Avid NEXIS specific information Section 12 in V1.32 is Section 2 in V2.0 Network Designs for NEXIS Section 13 in V1.23 is Section 3 in V2.0 Virtual Machines and Blade servers

V2.1 03 APR 2018 Up to 91 Pages

V2.1 NOTES Change section 1 name to Avid Nexis Requirements ADD 1.0.3 Zones - an evolved definition ADD 1.3.1 Partially Tested Switches ADD 1.7.1 Catalyst 9000 ADD 4.0 Wide Area and Data Centre Networking ADD 4.1 MPLS ADD 4.2 Wavelength-division multiplexing ADD 4.3 Software Defined Networking –SDN ADD 4.4 VXLAN

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 239 of 242

Version, Name & DATE

Comment

ADD 4.5 Spine/Leaf Networks ADD 4.6 Adapter Teaming ADD B.33 Cisco Nexus vPC best practices ADD B.34 Cisco Nexus 93180LC port breakout ADD 1.3.1.2 Cisco Nexus 9348-GC-FXP Field testing (FEB 2018) UPDATE 1.3 Architecturally Capable Network switches ADD 1.8 Network Interface Cards

V2.2 05 OCT 2018 103 Pages

UPDATE 1.0.1 NEXIS and Latency UPDATE Section 1.1 Qualified Switches for Avid NEXIS ADD Section 1.9 Airspeed 5500 (3rd GENERATION) network connection UPDATE 2.3 Custom/Deployed designs - CISCO UPDATE 2.4 Custom/Deployed designs - JUNIPER ADD 2.5 Custom/Deployed designs – ARISTA ADD Appendix E – Useful articles UPDATE 1.8 Network Interface Cards UPDATE 1.6.2 Chassis Based Switch Families ADD 5.1 Media Central UX Bandwidth requirements UPDATE B.22 Speed setting on Switch ports

V2.3 26 APR 2019 132 Pages

UPDATE: 1.0.1 NEXIS and Latency UPDATE: 1.1 Qualified Switches for Avid NEXIS UPDATE: 1.3 Architecturally Capable Network switches UPDATE: 1.7.1 Catalyst 9000 ADD 1.8.4 10GBASET Transceivers UPDATE 4.6.4 Linux Bonding ADD 5.2 Media Central Cloud UX Server Connectivity requirements ADD Section 7.0 Custom Testing UPDATE: B.5 Deploy BPDU guard on all ports that use PORTFAST ADD B5.2 Using spanning-tree port type edge with Cisco Nexus and AVID NEXIS UPDATE: B.20 Multicast Propagation Does Not Work in the same VLAN in Catalyst and NEXUS Switches ADD B.20.3 – UCS Blade Servers Multicast Propagation UPDATE B.22 Speed setting on Switch ports UPDATE B.29 Service Timestamps and Time setting in Dell N3024/48 UPDATE B.30 Service Timestamps and Time setting in DELL S4048 UPDATE B.31 HOW TO FIND IP ADDRESS OF A MAC ADDRESS ADD B.36 LINUX CONFIGURATION FOR TEAMED ADAPTERS ADD B.37 NEXUS WATCH COMMAND (FIELD-TIP) ADD B.38 AUTOMATING BACKING UP CISCO CONFIG FILES ADD Appendix F – Which Cisco Operating system to use? (IMPORTED SECTION from NETREQS V1.x) ADD B.39 NEXUS 93xxx USEFUL COMMANDS FROM SHOW TECH ADD INFOR ON SPICEWORKS & LORIOT PRO 8 for SNMP and LOG MANAGEMENT ADD INFOR on Catalyst auto backup for config file (SEE END OF DOC

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 240 of 242

Version, Name & DATE

Comment

AND SAME FOR NEXUS

V2.4 11OCT2019 153 pages

UPDATE 1.2 Approved Switches for Avid NEXIS ADD 1.5.2 Breakout cables NEXIS and NEXUS 93180 ADD 1.8.5 I350-T2 NIC Eol – Replaced by I350T2V2 UPDATE 1.8.4 10GBASET Transceivers UPDATE 2.2.2 MLAG/VSS ADD 2.3.3.1 Cisco Nexus 9336C with Nexus N93108TC/9348GC ADD 2.6 SPINE/LEAF - Custom/Deployed designs ADD 4.7 Cisco Transceiver Enterprise-Class versions ADD 4.8 Jumbo Frames and Avid applications ADD B.20.4 Some other useful Multicast URL & Information MINOR UPDATE: B.36 LINUX TEAM CONFIGURATION FOR TEAMED ADAPTERS ADD B.34.3 Optical breakout useful information ADD B.34.4 TWINAX breakout useful information ADD B.39.2 Show interface counters - Errors only ADD B.39.3 NEXUS copy run start SHORTCUT ADD B.40 NEXUS FX2 Models and ISIS STORAGE LIMITATIONS ADD B.41 Using DHCP with Avid Applications ADD B.42 IP address allocation with NEXIS and MediaCentral ADD B.43 Navigating Cisco NXOS versions

V2.5 13FEB2020 175 pages

UPDATE 1.1 Qualified Switches for Avid NEXIS >>> C4500X end of life announcement UPDATE 1.2 Approved Switches for Avid NEXIS ADD 1.10 NAT/PAT Incompatibility ADD 1.7.2 Catalyst 9000. B series ADD 1.5.3 Breakout cables NEXIS and DELL S4048 ADD 4.6.5 Teaming with FastServe Ingest UPDATE B.20.2.1 – Field Knowledge NEXUS & Multicast UPDATE B.34 Cisco Nexus 93000 series Port Breakout & QSA UPDATE B.34.3 Optical breakout useful information ADD B.34.5 QSA adapter UPDATE B.39.2 Show interface counters - Errors only ADD B.39.4 NEXUS other useful alias SHORTCUTS ADD B.44 FIELD TIP: large file sending ADD B.45 FIELD TIP: Upgrading Nexus 9000 switch firmware ADD B.46 Multicast propagation on DELL switches ADD B.47 Multicast propagation on Arista switches ADD B.48 Useful cabling information

V2.6 20JUL2020 173 pages

UPDATE section 1.3 in regard of Minimum S/W version for NXOS on 93000 FX series to use 7.0(3)I7(6) ADD 1.5.4 Avid supplied 40G Transceivers and NEXIS ADD 1.5.5 3rd Party Transceivers and Switch Vendors UPDATE 1.10.1 Kubernetes – the “core” of the “network” problem UPDATE 2.2.1 The Traditional/Legacy way UPDATE 2.2.2 MLAG/vPC/VSS Single Controller

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 241 of 242

Version, Name & DATE

Comment

UPDATE 2.2.3 MLAG/vPC/VSS Dual Controller ADD 4.9 NO specific VPN requirements for use with Thin Client applications UPDATE B.20.2 – Nexus switches Multicast Propagation UPDATE B.33 Cisco Nexus vPC Best Practices UPDATE B.39.1 SHOW COMMANDS NEXUS 93xxx USEFUL COMMANDS FROM SHOW TECH ADD B.49 LACP for NEXIS clients – is it supported?

V2.7 27JAN2021 191 pages

ADD 1.1.1 Issues to be aware of with Dell S4100 Series Switches UPDATE 1.10.1 Kubernetes – the “core” of the “network” problem with MCCUX ADD 1.7.3 Catalyst 9000 - B series – USING SOFTMAX ONLY UPDATE 1.8.3 NICs in a VM environment – applies to bare metal too ADD 4.6.4.1 LINUX TEAMING UPDATE B.20.2.2 – Field Knowledge NEXUS & Multicast PART 2UPDATE B.25 Serial connection alternatives to DB9 using USB (FIELD-TIP) ADD B25.1. Use the management network on NEXUS switches & remote connection ADD B.36.6 DEPLOYMENT CONSIDERTATIONS with MEDIA CENTRAL CLOUD UX ADD B.46.1 DELL 0S10 IGMP SNOOPING ADD B.50 Flow control with AVID Nexis storage – is it needed? ADD B.51 Flow control in Cisco NEXUS switches with AVID Nexis storage ADD B.52 Flow control in Dell S4048 switches with AVID Nexis storage ADD B.53 Mellanox ConnectX-3 adapter firmware version in NEXIS ADD B.54 DELL S4100 OS10 vs. OS9 LACP and VLT commands

V2.8 24MAY2021 222 pages

ADD 1.1.2 Dell S4100 Series Switches Model Variants UPDATE 1.3.0 Known Cisco Issues impacting Avid Storage solutions ADD 1.3.1.5 Cisco Nexus 93180YC-FX3 ADD 1.5.6 Gigabit Media Converters UPDATE 1.8.3 NICs in a VM environment – applies to bare metal too UPDATE 1.6.1 1U Switch Families UPDATE 1.10.1 Kubernetes – the “core” of the “network” problem with MCCUX (added paragraph at end.) ADD 1.10.2 MCCUX “Kubernetes” – NO LONGER USING MULTICAST MINOR UPDATE B.20 Multicast Propagation Does Not Work in the same VLAN in Catalyst and NEXUS Switches ADD 2.5.2 ARISTA - PROVEN DEPLOYMENTS WITH NEXIS UPDATE B.20.2.1 – Field Knowledge NEXUS & Multicast PART 1 UPDATE B.36.2 TEXT of COMMANDS for LACP SIMILAR UPDATE B.36.4 LACP TEAMING CONCLUSIONS SIMILAR UPDATE B.49 LACP for NEXIS clients – is it supported? UPDATE B.36 (.0) LINUX TEAM CONFIGURATION FOR TEAMED ADAPTERS ADD B.36.7 CHECKING/DEBUGGING LACP BOND CONNECTION STATUS in LINUX ADD B.55 CISCO SWITCH HARDWARE BEACONS ADD B.56 DELL N3224 FIRST SETUP ADD B.57 DELL N3024 N2024 DEFAULT INTERFACE COMMANDS ADD B.58 DELL N3024 N2024 PASSWORD RECOVERY

V2.9 07DEC 2021 245 pages

UPDATE 1.0.3 Zones - an evolved definition UPDATE 1.1.1.2 DELL S4100 VLT issue with NEXIS ADD 1.1.1.3 DELL OS10 Certificate Issue

NETREQS2_for_NEXIS_and_MediaCentral_V2.9.docx Page 242 of 242

Version, Name & DATE

Comment

UPDATE 1.2 Approved Switches for Avid NEXIS ADD 1.2.1 SWITCH GRADING UPDATE 1.3.0 Known Cisco Issues impacting Avid Storage solutions UPDATE: 1.5.3 Breakout cables NEXIS and DELL OS9/OS10 ADD 1.8.6 Architecturally Capable NIC Chipsets ADD 1.8.7 Known Vendor NIC Chipsets UPDATE 1.5.4 Avid supplied 40G Transceivers and NEXIS ADD 2.4.4 QFX 5120 & EX4400 NETWORK DESIGN UPDATE 2.6 SPINE/LEAF - Custom/Deployed designs UPDATE 7.1 TESTING BONDED ADAPTER WITH MEDIA CENTRAL CLOUD UX SERVER ADD 7.3 JUNIPER QFX5210 and EX4400 APPROVAL - SEP 2021 ADD 7.3.1 QFX QFX5120 CUSTOM TEST ADD 7.3.2 EX4400 CUSTOM TEST ADD 4.6.4 Windows Server TEAMING – MORE ARTICLES UPDATE 4.6.5.1 LINUX TEAMING UPDATE B.12 Get Putty 0.06 (or later) ADD B.20.5 Some good tutorials on IGMP SNOOPING ADD B.20.6 Wireshark examples on IGMP SNOOPING UPDATE B.36.7 CHECKING/DEBUGGING LACP BOND CONNECTION STATUS in LINUX ADD B.59 SRT LEARNING RESOURCES ADD E.2 CISCO FABRIC INTERCONNECT TUTORIAL ADD E.3 Packet Life and CLOUDSHARK ADD E.4 Articles on Loopback interfaces ADD E.5 MULTICAST ARTICLES & TUTORIALS ADD E.6 SDWAN ARTICLES & TUTORIALS ADD E.7 AZURE TUTORIALS & ARTICLES ADD E.8 KUBERNETES TUTORIALS & ARTICLES ADD F.2 NEXUS and NXOS – Which one to choose?