S.No Discipline / Group Product / Material of Test Specific Test Performed Test Method Specification against which tests are performed Range of Testing/ Limits of Detection 1530 ELECTRICAL- CABLES & WIRES Winding Wires for submersible motors - Part 4 Specification for individual wires: Section 3 Polyester and Polypropylene Insulated Winding Wires Water Absorption Test (Gravimetric) IS 8783 (Part 4, Sec 3): 1995 0 mg/cm² to 20 mg/cm² 1531 ELECTRICAL- INDUCTORS & TRANSFORMERS Dry-Type Power Transformers Winding Resistance IS 11171: 1985 1.9999 m ohm to 1.9999 K ohm 1532 ELECTRICAL- INDUCTORS & TRANSFORMERS Dry-Type Power Transformers upto 1.25 MVA & 11 kV Short Circuit Impedance and Load Loss IEC 60076-11: 2005 1V, 1A, 1W to 900V, 100A, 300 kW 1533 ELECTRICAL- INDUCTORS & TRANSFORMERS Dry-Type Power Transformers upto 1.25 MVA & 33 kV No Load Loss and Current IS 11171: 1985 1 V, 500 mA, 1 W to 900V, 20A, 18 kW 1534 ELECTRICAL- INDUCTORS & TRANSFORMERS Dry-Type Power Transformers upto 1.25 MVA & 33 kV No Load Loss and Current IEC 60076-11: 2005 1V, 500 mA, 1W to 900V, 20A, 18 kW 1535 ELECTRICAL- INDUCTORS & TRANSFORMERS Dry-Type Power Transformers upto 11 kV, 1250 kVA Short Circuit Impedance and Load Loss IS 11171: 1985 1V, 1A, 1W to 900V, 100A, 300 kW 1536 ELECTRICAL- INDUCTORS & TRANSFORMERS Dry-Type Power Transformers upto 11 kV, 1250 kVA Temperature Rise IS 11171: 1985 Ambient to 100 oC 1537 ELECTRICAL- INDUCTORS & TRANSFORMERS Dry-Type Power Transformers upto 33 kV Lightening Impulse voltage withstand IS 11171: 1985 Qualitative This is annexure to 'Certificate of Accreditation' and does not require any signature. Laboratory Name RAJASTHAN TEST & RESEARCH CENTRE, PLOT NO. 296, SECTOR-7, GURGAON, HARYANA, INDIA Accreditation Standard ISO/IEC 17025:2017 Certificate Number TC-5073 Page No. : 248 / 256 Validity 08/12/2018 to 07/12/2020 Last Amended on 12/02/2019

Transcript of Laboratory Name Accreditation Standard Certificate Number ...

S.No Discipline / Group Product / Material ofTest

Specific TestPerformed

Test MethodSpecificationagainst which testsare performed

Range of Testing/Limits of Detection

1530 ELECTRICAL-CABLES & WIRES

Winding Wires forsubmersible motors -Part 4 Specification forindividual wires:Section 3 Polyesterand PolypropyleneInsulated WindingWires

Water Absorption Test(Gravimetric)

IS 8783 (Part 4, Sec 3):1995

0 mg/cm² to 20 mg/cm²

1531 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-Type PowerTransformers

Winding Resistance IS 11171: 1985 1.9999 m ohm to1.9999 K ohm

1532 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-Type PowerTransformers upto 1.25MVA & 11 kV

Short CircuitImpedance and LoadLoss

IEC 60076-11: 2005 1V, 1A, 1W to 900V,100A, 300 kW

1533 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-Type PowerTransformers upto 1.25MVA & 33 kV

No Load Loss andCurrent

IS 11171: 1985 1 V, 500 mA, 1 W to900V, 20A, 18 kW

1534 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-Type PowerTransformers upto 1.25MVA & 33 kV

No Load Loss andCurrent

IEC 60076-11: 2005 1V, 500 mA, 1W to900V, 20A, 18 kW

1535 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-Type PowerTransformers upto 11kV, 1250 kVA

Short CircuitImpedance and LoadLoss

IS 11171: 1985 1V, 1A, 1W to 900V,100A, 300 kW

1536 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-Type PowerTransformers upto 11kV, 1250 kVA

Temperature Rise IS 11171: 1985 Ambient to 100 oC

1537 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-Type PowerTransformers upto 33kV

Lightening Impulsevoltage withstand

IS 11171: 1985 Qualitative

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name RAJASTHAN TEST & RESEARCH CENTRE, PLOT NO. 296, SECTOR-7, GURGAON,HARYANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number TC-5073 Page No. : 248 / 256

Validity 08/12/2018 to 07/12/2020 Last Amended on 12/02/2019

S.No Discipline / Group Product / Material ofTest

Specific TestPerformed

Test MethodSpecificationagainst which testsare performed

Range of Testing/Limits of Detection

1538 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-Type PowerTransformers upto 33kV

Separate Sourcevoltage withstand(Primary & SecondaryWinding)

IS 11171: 1985 3 kV to 75 kV

1539 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-Type PowerTransformers upto 33kV & 1250 kVA

Induced over voltagewithstand

IS 11171: 1985 1 V to 1000 V

1540 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-Type PowerTransformers upto 33kV & 1250 kVA

Voltage ratio and checkof phase displacement

IS 11171: 1985 2 to 200

1541 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-type transformers Induced over voltagewithstand

IEC 60076-11: 2018 1 V to 1000 V

1542 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-type transformers Lightening Impulsevoltage withstand

IEC 60076-11: 2018 Qualitative

1543 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-type transformers Separate Sourcevoltage withstand(Primary & SecondaryWinding)

IEC 60076-11: 2018 3 V to 75 kV

1544 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-type transformersupto 1.25 MVA & 33 kV

Voltage ratio and checkof phase displacement

IEC 60076-11: 2005 2 to 200

1545 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-type transformersupto 1.25 MVA & 33 kV

Winding Resistance IEC 60076-11: 2005 1.9999 m ohm to1.9999 K ohm

1546 ELECTRICAL-INDUCTORS &TRANSFORMERS

Dry-type transformersupto 11 kV, 1250 kVA

Temperature Rise IEC 60076-11: 2005 -10 oC to 100 oC

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name RAJASTHAN TEST & RESEARCH CENTRE, PLOT NO. 296, SECTOR-7, GURGAON,HARYANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number TC-5073 Page No. : 249 / 256

Validity 08/12/2018 to 07/12/2020 Last Amended on 12/02/2019

S.No Discipline / Group Product / Material ofTest

Specific TestPerformed

Test MethodSpecificationagainst which testsare performed

Range of Testing/Limits of Detection

1547 ELECTRICAL-INDUCTORS &TRANSFORMERS

Insulating Oils Oil Breakdown Voltage IS 6792: 2003 20 KV to 100 kV

1548 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor type three-phase distributiontransformers up to andincluding 100 kVA 11kV

Air Pressure IS 1180 (Part 2): 1989 0 kg/cm2 to 1.06kg/cm2

1549 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor type three-phase distributiontransformers up to andincluding 100 kVA 11kV, Part 2: Sealed type

Over Fluxing IS 1180 (Part 2): 1989 500 mA, 1 V to 20 A,1000 V

1550 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformer upto 1.25MVA & 33 kV

Air Pressure CBIP Manual oftransformer-295: 2006

0 kg/cm2 to 1.06kg/cm2

1551 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformer upto 1.25MVA & 33 kV

Air Pressure CBIP Maual ofTransformer 317: 2013

0 kg/cm2 to 1.06kg/cm2

1552 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformer upto 1.25MVA & 33 kV

Lightning Impulsevoltage withstand

IEEE 57.12.90: 2015 Qualitative

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name RAJASTHAN TEST & RESEARCH CENTRE, PLOT NO. 296, SECTOR-7, GURGAON,HARYANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number TC-5073 Page No. : 250 / 256

Validity 08/12/2018 to 07/12/2020 Last Amended on 12/02/2019

S.No Discipline / Group Product / Material ofTest

Specific TestPerformed

Test MethodSpecificationagainst which testsare performed

Range of Testing/Limits of Detection

1553 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformer upto 1.25MVA & 33 kV

Magnetic Balance CBIP Publication -Manual of TransformerGP-295: 2006

300 mV to 750 V

1554 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformer upto 1.25MVA & 33 kV

Magnetic Balance CBIP Manual ofTransformer GP-317:2013

300 mV to 750 V

1555 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformer upto 1.25MVA & 33 kV

Unbalance Current CBIP Manual ofTransformer -317: 2013

60 mA to 20 A

1556 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformer upto 1.25MVA & 33 kV

Unbalance Current CBIP Manual oftransformer 275: 1999

60 mA to 20 A

1557 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformer upto 1.25MVA & 33 kV

Vacuum Test up to 200kVA

CBIP Manual ofTransformer -317: 2013

0 mm Hg to -760 mmHg

1558 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformer upto 200kVA & 33 kV

Vacuum Test CBIP Manual ofTransformer 295: 2006

0 mm Hg to -760 mmHg

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name RAJASTHAN TEST & RESEARCH CENTRE, PLOT NO. 296, SECTOR-7, GURGAON,HARYANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number TC-5073 Page No. : 251 / 256

Validity 08/12/2018 to 07/12/2020 Last Amended on 12/02/2019

S.No Discipline / Group Product / Material ofTest

Specific TestPerformed

Test MethodSpecificationagainst which testsare performed

Range of Testing/Limits of Detection

1559 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformers Up toand Including 1250kVA, 11 kV

Short CircuitImpedance and LoadLoss

IS 1180 (Part 1): 2014 1V, 1A 1W to 900V,100A, 300 kW

1560 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformers Up toand Including 1250kVA, 11 kV

Temperature Rise IS 1180 (Part 1): 2014 ambient to 100 oC

1561 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformers Up toand Including 1250kVA, 33kV

Air Pressure IS 1180 (Part 1): 2014 0 kg/cm2 to 1.06kg/cm2

1562 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformers Up toand Including 1250kVA, 33kV

No Load Loss andCurrent

IS 1180 (Part 1): 2014 1V, 500 mA, 1W to205V, 20A, 18 kW

1563 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformers Up toand Including 2 500kVA, 33 kV

Winding Resistance IS 1180 (Part 1): 2014 1.9999 m ohm to1.9999 K ohm

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name RAJASTHAN TEST & RESEARCH CENTRE, PLOT NO. 296, SECTOR-7, GURGAON,HARYANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number TC-5073 Page No. : 252 / 256

Validity 08/12/2018 to 07/12/2020 Last Amended on 12/02/2019

S.No Discipline / Group Product / Material ofTest

Specific TestPerformed

Test MethodSpecificationagainst which testsare performed

Range of Testing/Limits of Detection

1564 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformers Up toand Including 2 500kVA, 33kV

Induced over voltagewithstand

IS 1180 (Part 1): 2014 1 V to 1000 V

1565 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformers Up toand Including 2 500kVA, 33kV

Insulation Resistance IS 1180 (Part 1): 2014 1 M ohm to 5000 Mohm

1566 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformers Up toand Including 2 500kVA, 33kV

Oil Leakage Test IS 1180 (Part 1): 2014 0 kg/cm2 to 1.06kg/cm2

1567 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformers Up toand Including 2 500kVA, 33kV

Over Fluxing IS 1180 (Part 1): 2014 500 mA to 20 A

1568 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformers Up toand Including 2 500kVA, 33kV

Separate Sourcevoltage withstand(Primary & SecondaryWinding)

IS 1180 (Part 1): 2014 3 kV to 75 kV

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name RAJASTHAN TEST & RESEARCH CENTRE, PLOT NO. 296, SECTOR-7, GURGAON,HARYANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number TC-5073 Page No. : 253 / 256

Validity 08/12/2018 to 07/12/2020 Last Amended on 12/02/2019

S.No Discipline / Group Product / Material ofTest

Specific TestPerformed

Test MethodSpecificationagainst which testsare performed

Range of Testing/Limits of Detection

1569 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformers Up toand Including 2 500kVA, 33kV

Vacuum Test up to 200kVA

IS 1180 (Part 1): 2014 0 mm Hg to -760 mmHg

1570 ELECTRICAL-INDUCTORS &TRANSFORMERS

Outdoor/Indoor TypeOil ImmersedDistributionTransformers Up toand Including 2 500kVA, 33kV

Voltage ratio and checkof phase displacement

IS 1180 (Part 1): 2014 2 to 200

1571 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformer upto33 kV

Induced over voltagewithstand

IS 2026 (Part 1): 2011 1 V to 1000 V

1572 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformers Separate Sourcevoltage withstand(Primary & SecondaryWinding)

IEC 60076-1: 2011 3 V to 75 kV

1573 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformers Short CircuitImpedance and LoadLoss

IS 2026 (Part 1): 2011 0 V to 1008 V

1574 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformers Winding Resistance IS 2026 (Part 1): 2011 1.9999 m ohm to1.9999 K ohm

1575 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformers Winding Resistance IEC 60076-1: 2011 1.9999 m ohm to1.9999 K ohm

1576 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformersupto 33 kV

Insulation Resistance IS 60076-1: 2011 1 M ohm to 5000 Mohm

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name RAJASTHAN TEST & RESEARCH CENTRE, PLOT NO. 296, SECTOR-7, GURGAON,HARYANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number TC-5073 Page No. : 254 / 256

Validity 08/12/2018 to 07/12/2020 Last Amended on 12/02/2019

S.No Discipline / Group Product / Material ofTest

Specific TestPerformed

Test MethodSpecificationagainst which testsare performed

Range of Testing/Limits of Detection

1577 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformersupto 1.25 MVA & 33 kV

No Load Loss andCurrent

IS 2026 (Part 1): 2011 1V, 500 mA, 1W to900V, 20A, 18 kW

1578 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformersupto 11 kV & 1250 kVA

Short CircuitImpedance and LoadLoss

IEC 60076-1: 2011 1V,1A, 1W to 900V,100A, 300 kW

1579 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformersupto 11 kV & 1250 kVA

Temperature Rise IEC 60076-2: 2011 Ambient to 100 oC

1580 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformersupto 11 kV, 1250 kVA

Temperature Rise IS 2026 (Part 2): 2011 Amibent oC to 100 oC

1581 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformersupto 33 kV

Induced over voltagewithstand

IEC 60076-1: 2011 1 V to 1000 V

1582 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformersupto 33 kV

Insulation Resistance IS 2026 (Part 1): 2011 1 M ohm to 5000 Mohm

1583 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformersupto 33 kV

Lightening Impulsevoltage withstand

IEEE 57.12.60: 2009 Qualitative

1584 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power Transformersupto 33 kV

Lightening Impulsevoltage withstand

IS 2026 (Part 3): 2009 Qualitative

1585 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformersupto 33 kV

Lightening Impulsevoltage withstand

IEC 60076-3: 2013 Qualitative

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name RAJASTHAN TEST & RESEARCH CENTRE, PLOT NO. 296, SECTOR-7, GURGAON,HARYANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number TC-5073 Page No. : 255 / 256

Validity 08/12/2018 to 07/12/2020 Last Amended on 12/02/2019

S.No Discipline / Group Product / Material ofTest

Specific TestPerformed

Test MethodSpecificationagainst which testsare performed

Range of Testing/Limits of Detection

1586 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformersupto 33 kV

Separate Sourcevoltage withstand(Primary & SecondaryWinding)

IS 2026 (Part 1): 2011 3 kV to 75 kV

1587 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformersupto 33 kV

Voltage ratio and checkof phase displacement

IS 60076-1: 2011 2 to 200

1588 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformersupto 33 kV & 1.25 MVA

No Load Loss andCurrent

IEC 60076-1: 2011 1V, 500 mA, 1W to900V, 20A, 18 kW

1589 ELECTRICAL-INDUCTORS &TRANSFORMERS

Power transformers, Voltage ratio and checkof phase displacement

IS 2026 (Part 1): 2011 2 to 200

This is annexure to 'Certificate of Accreditation' and does not require any signature.

Laboratory Name RAJASTHAN TEST & RESEARCH CENTRE, PLOT NO. 296, SECTOR-7, GURGAON,HARYANA, INDIA

Accreditation Standard ISO/IEC 17025:2017

Certificate Number TC-5073 Page No. : 256 / 256

Validity 08/12/2018 to 07/12/2020 Last Amended on 12/02/2019