Kinetico Drinking Water System - Plus Deluxe Models VX & GX

22
Kinetico Drinking Water System Plus Deluxe Models VX & GX

Transcript of Kinetico Drinking Water System - Plus Deluxe Models VX & GX

Kinetico Drinking Water SystemPlus Deluxe Models VX & GX

PERFORMANCE DATA SHEETPERFORMANCE DATA SHEETKinetico Drinking Water System

Plus Deluxe Models

KineticoIncorporated10845KinsmanRoad,Newbury,Ohio44065 440-564-9111 Rev10/05ProductNo.11355A

2

KineticoDrinkingWaterSystemPlusDeluxeGXandVXmodelsaretestedandcertifiedtoNSF/ANSIStandard42forthereductionofKineticoDrinkingWaterSystemPlusDeluxeGXandVXmodelsaretestedandcertifiedtoNSF/ANSIStandard42forthereductionofaestheticchlorine,tasteandodorandtoStandard58forthereductionofsubstanceslistedherein.VXmodelsarealsotestedandcertifiedtoNSF/ANSIStandard53forVOC(volatileorganiccompounds)andMTBE(methyltertiarybutylether)reduction.

Inaddition,thematerialsandcomponentsaswellasthedesignandconstructionofthissystemhavebeentestedbyNSFInternationaltotherequirementsofNSF/ANSIStandard58.Thisistoassurethatlevelsofextractablecontaminantsdonotexceedestablishedlimitsandthatthesystemwillaccomplishitsintendedpurposewheninstalledandoperatedaccordingtothemanufacturer’sinstructions.

REPLACEMENT CARTRIDGES FOR KINETICO DRINKING WATER SYSTEM PLUS DELUXE MODELS

Prefilter ROMembrane MACGuard™Postfilter

CHLORINATEDWATERSUPPLY

(CityWaterorChlorinatedWell)

NON-CHLORINATEDWATERSUPPLY

75gpd/285LpdROMembrane(PartNo.10501)

ALLWATERSUPPLIES(CITYWATERORWELL)

HighCapacityCarbon/SedimentPrefilter

(PartNo.9461A)

SedimentPrefilter(PartNo.9309A)

ForGXModelsTaste&OdorPostfilter

(PartNo.9306B)

ForVXModelsTaste,Odor,MTBE&VOCPostfilter

(PartNo.9307A)

PERFORMANCE and MAINTENANCEThisreverseosmosissystemcontainsreplaceabletreatmentcomponentscriticalfortheeffectivereductionoftotaldissolvedsolids(TDS).Testtheproductwaterquarterlytoverifythatthesystemisperformingsatisfactorily.ThissystemhasbeentestedandverifiedbyNSFInternationalandtheWQAthatitwilldecreasethedischargeofproductwaterby50%orgreaterat500gallons.Thisshutdownpre-ventstheeffluentcontaminantlevelfromexceedingtheEPA’smaximumcontaminantlevelundernormaloperatingconditions.Torestoreservice,replaceboththeprefilterandpostfiltercartridges.Annualreplacementisrecommendedevenifyoursystemhasnotyetshutdown.Seethechartabovetoselectcartridgesforyoursystem.ThesecartridgesareavailablethroughyourlocalKineticodealer.Youmayopttohavetheproductwatertestedatthistimetoverifyperformance.Foroperationandmaintenanceinformation,consulttheowner’smanual.InstallationinstructionsareavailableforreviewfromyourauthorizedKineticodealer.

WARRANTY COVERAGETheKineticoDrinkingWaterSystemPlusDeluxecarriesalimitedmanufacturer’swarranty.IftheKineticoDrinkingWaterSystemPlusDeluxeisinstalledinconjunctionwithaKineticoWaterConditioner,thewarrantycoversthepartsoftheKineticoDrinkingWaterSystemPlusDeluxeforsevenyearsandthereverseosmosismembraneforsevenyears.IftheKineticoDrinkingWaterSystemPlusDeluxeisinstalledwithoutaKineticoWaterConditioner,thePlusDeluxesystempartsarecoveredforsevenyearsandthemem-braneiscoveredforfouryears.Forcompletedetails,seetheactualwarranty.Thewarrantywillbevoidifinfluentwaterconditionsexceedthosespecifiedinthesystemparameters.

IMPORTANT•Donotuseonwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequatedisinfectionbeforeorafterthesystem.Systemscertified

forcystreductionmaybeusedondisinfectedwaterthatmaycontainfilterablecysts.•Installationofthisproductmustcomplywithallapplicablelaws.•Provisionsforanantisiphonairgapshouldbepartoftheinstallationtopreventacrossconnectionbetweenthewatersystemandthewastesystem.•Donotuseonwaterthatcontainsmorethan0.1ppmiron,morethan10gpghardness,morethan3000ppmTDSorthatfallsoutsidethepHrangeof

3to11.Donotusesystemswithsedimentprefiltersonwaterthatcontainschlorine.•Ifanoticeablechangeinproductwaterproduction,tasteorodoroccurs,contactyourauthorizedKineticodealer.•Modelsusedfornitrate/nitritereductionareacceptablefortreatmentofinfluentconcentrationsofnomorethan27mg/Lnitrateand3mg/Lnitritein

combinationmeasuredasNandarecertifiedfornitrate/nitritereductiononlyforwatersupplieswithapressureof280kPa(40psig)orgreater(withtestkit–partno.7329with1gal/3.8LQuickFlotank,3gal/11.4LQuickFlotankorstandardtank).

•Ifyoupurchasedyoursystemspecificallyfornitratereduction,Kineticorecommendsperiodic(quarterly)testingwithanitrate/nitritetestkit(partno.7329)toassurethatnitrate/nitritesarebeingreducedtoacceptablelevels.

PERFORMANCE DATA SHEETPERFORMANCE DATA SHEETKinetico Drinking Water System

Plus Deluxe Models

KineticoIncorporated10845KinsmanRoad,Newbury,Ohio44065 440-564-9111 Rev10/05ProductNo.11355A

3

SUBSTANCE

TestPressure(psi)

FlowR

ate(gpm

)

Temperature(°F)

pH

Average

InfluentA

verageA

verage

Level(m

g/L)

Average

Effluent

Average

Average

Level(m

g/L)

Maxim

umE

ffluentLevel

(mg/L)

PercentR

eduction

Minim

umPercent

Reduction

USE

PAM

CL

(mg/L)

InfluentC

hallengeC

oncentration(m

g/L)

Maxim

umPerm

issibleProductW

aterC

oncentrations(m

g/L)

PentavalentArsenicC 50 0.75 77 5.89 0.30 <0.001 0.004 99.7 98.5 0.010 0.30±10%

Barium 50 0.75 77 5.81 10.2 0.13 0.27 98.7 ---- 2.0 10.0±10%

HexavalentChromium 50 0.75 77 5.89 0.3 0.006 0.013 98.0 ---- .05 0.3±10% 0.1

TrivalentChromium 50 0.75 77 5.81 0.30 0.003 0.008 99.0 ---- .05 0.3±10% 0.1

Cadmium 50 0.75 77 7.53 0.031 0.0001 0.0009 99.7 ---- 0.005 0.03±10% 0.005

AestheticChlorine 60 0.75 67.6 7.55 1.8 0.04 0.10 97.7 94.4 ---- 2.0±10%

Copper 50 0.75 77 7.51 3.0 0.04 0.06 98.7 ---- ---- 3.0±10% 1.3

Fluoride 50 0.75 77 7.53 8.0 0.33 0.47 95.9 96 4.0 8.0±10% 1.5

*MTBEmethyltertiarybutylether 60 0.75 65 7.68 0.015 0.0006 0.0012 95.7 92 ---- 0.015±20% 0.005

Radium226/228 50 0.75 77 5.81 25pCi/L 5pCi/L 5 80 ---- 5pCi/L 25pCi/L±10% 5pCi/L

Selenium 50 0.75 77 7.53 0.10 <0.001 <0.001 99.0 ---- 0.05 0.10±10% 0.05

Lead 50 0.75 77 5.68 0.15 0.004 0.008 97.3 ---- 0.015 0.15±10% 0.010

CystA (3-4micron) 50 0.75 77 7.81 140000/ml 8/ml 20/ml 99.99 ---- ---- Min

50,000/ml 99.95%

Turbidity 50 0.75 69.8 7.52 81NTU 0.15NTU

0.28NTU 99.8 97.9 ---- 11±1NTU 0.5NTU

*VOCsB 60 0.75 68.8 7.90 0.29 0.0011 0.0037 99.6 98.7 ---- ---- ----

Drinking Water System Plus Deluxe

A-Cystreductionincludesoocystsofcryptosporidiumandcystsofgiardiaandentamoeba.Cystinfluentandeffluentaremeasuredin#/ml.B-ChloroformwasusedasasurrogateforthesechemicalsperNSF/ANSIStandard53.*VXModelsonlyCaliforniaDept.ofHealthServicescertificatenumbersforPlusDeluxeGXModel:05-1577w/1GQuickFlo;05-1726w/3GQuickFlo;05-1725w/3Gair-chargedtank.CaliforniaDept.ofHealthServicescertificatenumbersforPlusDeluxeVXModel:05-1578w/1GQuickFlo;05-1724w/3GQuickFlo;05-1723w/3Gair-chargedtank.C-ConformstoNSF/ANSI53forpentavalentarsenicreduction.Seepage6foradditionalarsenictreatmentfacts.

TheKineticoDrinkingWaterSystemPlusDeluxeistestedandcertifiedunderNSF/ANSIStandard58forthereductionofPentavalentarsenic,barium,cadmium,copper,cysts(includingoocystsofcryptosporidiumandcystsofgiardiaandentamoeba),fluoride,hexavalentchromium,lead,nitrite/nitrate(withtestkit,partno.7329andonthe1gal/3.8LQuickFlotank,3gal/11.4LQuickFlotankandstandardtank),radium226/228,selenium,totaldissolvedsolids,turbidityandtrivalentchromiumandNSF/ANSIStandard42foraestheticchlorinetasteandodorreduction.VXmodelsarealsocertifiedtoNSF/ANSIStandard53forMTBEandVOCreductionasverifiedandsubstantiatedbytestdata.

CONTAMINANT REDUCTION CAPABILITIESIMPORTANTNOTICE! ReadthisperformancedatasheetandcomparethecapabilitiesofthePlusDeluxeunitwithyouractualwatertreatmentneeds.Pleasenotethatthecontaminantslistedbelowarenotnecessarilyinyourwaterandthatwhiletestingwasperformedunderstandardlaboratoryconditions,actualperformancemayvary.Itisrecommendedthatbeforepurchasingawatertreat-mentunit,youhaveyourwatersupplytestedtodetermineyouractualwatertreatmentneeds.ThesystemhasbeentestedaccordingtoNSF/ANSIStandard42,53and58forreductionofthesubstanceslistedbelow.Theconcentrationoftheindicatedsubstancesinwaterenteringthesystemwasreducedtoaconcentrationlessthanorequaltothepermissiblelimitforwaterleavingthesystem,asspecifiedinNSF/ANSIStandard42,53and58.ThechartbelowcontainsthefollowinginformationbasedonNSFtestresults: • AlistofsubstancesthatwillbereducedbyKineticoDrinkingWaterSystemPlusDeluxemodels • Thepercentofreductionthatcanbeexpected • Conditionsunderwhichtheunitsweretested(pressure,pHandtemperature) • Influentandeffluentlevelsofcontaminatedtestedwater • TheUSEPA’smaximumcontaminantlevel(MCL)

2.0

0.010

----

----

PercentReduction

Requirem

ent

----

----

----

----

----

----

----

----

----

----

----

----

95%

≥50%

PERFORMANCE DATA SHEETPERFORMANCE DATA SHEETKinetico Drinking Water System

Plus Deluxe Models

KineticoIncorporated10845KinsmanRoad,Newbury,Ohio44065 440-564-9111 Rev10/05ProductNo.11355A

4

MODEL SPECIFIC INFORMATION

ModelName:DrinkingWaterSystemPlusDeluxeGXorVXwithStandardTankDischargeWater/ProductWaterRatio:3to1ProductWaterProductionRate(DailyProductionRate) 19.75gpd(74.76Lpd)EfficiencyRating1:25.94%,RecoveryRating2:40.25%

TestPressure(psi)

FlowR

ate(gpm

)

Temperature(°F)

Temperature

Temperature

pH

Average

InfluentA

verageA

verage

Level(m

g/L)

Average

Effluent

Average

Average

Level(m

g/L)

Maxim

umE

ffluentLevel

(mg/L)

Average

PercentR

eduction

Minim

umPercent

Reduction

USE

PAM

CL

(mg/L)

InfluentC

hallengeC

oncentration(m

g/L)

50 0.75 75.2 7.75 ---- ---- ---- ---- ---- 10.0 30.0±10%

50 0.75 75.2 7.75 28 5.4 7.8 80.71 72.14 10.0 27.0±10%

50 0.75 75.2 7.75 3.1 0.55 0.67 82.26 78.39 1.0 3.0±10%50 0.75 77 6.09 766 82.2 89 89.2 88.4 500 750±40mg/L

General Specifications (ALL MODELS)Minimum/MaximumOperatingTemperature:2°C-38°C(35°F-100°F)

AmbientTemperature,OperatingConditions:32°C/90°F Minimum/MaximumOperatingPressure:241.3-689.5kPa(35/100psi;40-100psi(275kPa-689.5kPa)fornitrate/nitritereduction)

A-TDSiscommonlycomprisedofcalcium,magnesium,sodium,iron,manganese,bicarbonate,chloride,sulfateandcarbonateA-TDSiscommonlycomprisedofcalcium,magnesium,sodium,iron,manganese,bicarbonate,chloride,sulfateandcarbonate1-EfficiencyRatingmeansthepercentageoftheinfluentwatertothesystemthatisavailabletotheuserasreverseosmosistreatedwaterunderoperatingconditionsthatapproximatetypicaldailyusage.2-RecoveryRatingmeansthepercentageoftheinfluentwatertothemembraneportionofthesystemthatisavailabletotheuserasreverseosmosistreatedwaterwhenthesystemisoper-atedwithoutastoragetankorwhenthestoragetankisbypassed.

ModelName:DrinkingWaterSystemPlusDeluxeGXorVXwith3GallonQuickFloTankDischargeWater/ProductWaterRatio:2.7to1ProductWaterProductionRate(DailyProductionRate)35.5gpd(134.4Lpd)EfficiencyRating1:27.52%,RecoveryRating2:35.19%

SUBSTANCE

TestPressure(psi)

FlowR

ate(gpm

)

Temperature(°F)

Temperature

Temperature

pH

Average

InfluentA

verageA

verage

Level(m

g/L)

Average

Effluent

Average

Average

Level(m

g/L)

Maxim

umE

ffluentLevel

(mg/L)

Average

PercentR

eduction

Minim

umPercent

Reduction

USE

PAM

CL

(mg/L)

InfluentC

hallengeC

oncentration(m

g/L)

Maxim

um

PermissibleProduct

WaterC

oncentrations(m

g/L)t

Nitrate/NitritebothasN 50 0.75 75.2 7.75 ---- ---- ---- ---- ---- 10.0 30.0±10% 10.0

Nitrate-N 50 0.75 75.2 7.75 26 3.2 4.81 87.69 81.54 10.0 27.0±10% 10.0

Nitrite-N 50 0.75 75.2 7.75 3 <0.50 <0.5 >83.3 >83.3 1.0 3.0±10% 1.0TDSA 50 0.75 77 6.10 759 38.3 46 94.9 93.9 500 750±40mg/L 187

ModelName:DrinkingWaterSystemPlusDeluxeGXorVXwith1GallonQuickFloTankDischargeWater/ProductWaterRatio:2.7to1ProductWaterProductionRate(DailyProductionRate) 32.45gpd(122.8Lpd)EfficiencyRating1:26.76%,RecoveryRating2:35.23%

SUBSTANCE

TestPressure(psi)

FlowR

ate(gpm

)

Temperature(°F)

Temperature

Temperature

pH

Average

InfluentA

verageA

verage

Level(m

g/L)

Average

Effluent

Average

Average

Level(m

g/L)

Maxim

umE

ffluentLevel

(mg/L)

Average

PercentR

eduction

Minim

umPercent

Reduction

USE

PAM

CL

(mg/L)

InfluentC

hallengeC

oncentration(m

g/L)

Maxim

umPerm

issibleProductW

aterC

oncentrations(m

g/L)

Nitrate/NitritebothasN 50 0.75 75.2 7.75 ---- ---- ---- ---- ---- 10.0 30.0±10% 10.0

Nitrate-N 50 0.75 75.2 7.75 28 5.4 7.8 80.71 72.14 10.0 27.0±10% 10.0

Nitrite-N 50 0.75 75.2 7.75 3.1 0.55 0.67 82.26 78.39 1.0 3.0±10% 1.0TDSA 50 0.75 77 6.42 761 24.07 29 96.8 96.18 500 750±40mg/L 187

----

----

--------

PercentReduction

Requirem

enPercentR

eductionR

equirement

----

----

--------

SUBSTANCE

Nitrate/NitritebothasNNitrate-N

Nitrite-NTDSA

Maxim

um

PermissibleProduct

WaterC

oncentrations(m

g/L)

10.0

10.01.0

187

PercentReduction

Requirem

ent

----

----

--------

PERFORMANCE DATA SHEETPERFORMANCE DATA SHEETKinetico Drinking Water System

Plus Deluxe Models

KineticoIncorporated10845KinsmanRoad,Newbury,Ohio44065 440-564-9111 Rev10/05ProductNo.11355A

5

VOCsInclude: USEPAMCLmg/L(ppm)

InfluentChallengeConcentrationmg/L(ppm)

ChemicalReductionPercent

MaximumPermissibleProductWater

Concentrationmg/L(ppm)

alachlor 0.002 0.050 >98 0.001

atrazine 0.003 0.10 >97 0.003

benzene 0.005 0.081 >99 0.001

carbofuran 0.04 0.190 >99 0.001

carbontetrachloride 0.005 0.078 98 0.0018

chlorobenzene 0.1 0.077 >99 0.001

chloropicrin ---- 0.015 99 0.0002

2,4-D 0.07 0.110 98 0.0017

dibromochloropropane(DBCP) 0.0002 0.052 >99 0.00002

o-dichlorobenzene 0.6 0.080 >99 0.001

p-dichlorobenzene 0.075 0.040 >98 0.001

1,2-dichloroethane 0.005 0.088 95 0.0048

1,1-dichloroethylene 0.007 0.083 >99 0.001

cis-1,2-dichloroethylene 0.07 0.170 >99 0.0005

trans-1,2-dichloroethylene 0.1 0.086 >99 0.001

1,2-dichloropropane 0.005 0.080 >99 0.001

cis-1,3-dichloropropylene ---- 0.079 >99 0.001

dinoseb 0.007 0.170 99 0.0002

endrin 0.002 0.053 99 0.00059

ethylbenzene 0.7 0.088 >99 0.001

ethylenedibromide(EDB) 0.00005 0.044 >99 0.00002

haloacetonitriles(HAN):bromochloroacetronitriledibromoacetonitriledichloroacetonitriletrichloroacetonitrile

----0.0220.0240.00960.015

98989898

0.00050.00060.00020.0003

haloketones(HK)1,1-dichloro-2-propanone1,1,1-trichloro-2-propanone

---- 0.00720.0082

9996

0.00010.0003

heptachlor 0.0004 0.25 >99 0.00001

heptachlorepoxide 0.0002 0.0107 98 0.0002

hexachlorobutadiene ---- 0.044 >98 0.001

hexachlorocyclopentadiene 0.05 0.06 >99 0.000002

lindane 0.0002 0.055 >99 0.00001

methoxychlor 0.04 0.05 >99 0.0001

pentachlorophenol 0.001 0.096 >99 0.001

simazine 0.004 0.12 >97 0.004

styrene 0.1 0.15 >99 0.0005

1,1,2,2-tetrachloroethane ---- 0.081 >99 0.001

tetrachloroethylene 0.005 0.081 >99 0.001

toluene 1.0 0.078 >99 0.001

2,4,5-TP(silvex) 0.05 0.27 99 0.0016

tribromoaceticacid ---- 0.042 >98 0.001

1,2,4-trichlorobenzene 0.07 0.16 >99 0.0005

1,1,1-trichloroethane 0.2 0.084 95 0.0046

1,1,2-trichloroethane 0.005 0.15 >99 0.0005

trichloroethylene 0.005 0.18 >99 0.001

trihalomethanes(surrogatechemical) 0.080 0.300 95 0.015

xylenes(total) 10.0 0.07 >99 0.001

PERFORMANCE DATA SHEETPERFORMANCE DATA SHEETKinetico Drinking Water System

Plus Deluxe Models

KineticoIncorporated10845KinsmanRoad,Newbury,Ohio44065 440-564-9111 Rev10/05ProductNo.11355A

6

Thissystemhasbeentestedforthetreatmentofwatercontainingpentavalentarsenic(alsoknownasAs(V),As(+5),andarsenate)atconcentrationsof0.30mg/Lorless.Thissystemreducespentavalentarsenic,butmaynotremoveotherformsofarsenic.Thissystemistobeusedonwatersuppliescontainingadetectablefreechlorineresidualatthesysteminletoronwatersuppliesthathavebeendemonstratedtocontainonlypentavalentarsenic.Treatmentwithchloramine(combinedchlorine)isnotsufficienttoensurecompleteconversionoftrivalentarsenictopentavalentarsenic.

Arsenic(abbreviatedAs)isfoundnaturallyinsomewellwater.Arsenicinwaterhasnocolor,tasteorodor.Itmustbemeasuredbyalabtest.Publicwaterutilitiesmusthavetheirwatertestedforarsenic.Youcangettheresultsfromyourwaterutility.Ifyouhaveyourownwell,youcanhavethewatertested.Yourlocalhealthdepartmentorstateenvironmentalhealthagencycanprovidealistofcerti-fiedlabs.Thecostistypically$15to$30.YoucanfindinformationaboutarsenicinwaterontheInternetattheUSEnvironmentalProtectionAgencywebsite:www.epa.gov/safewater/arsenic.html.

Therearetwoformsofarsenic:pentavalentarsenic(alsocalledAs(V),As(+5)andarsenate)andtrivalentarsenic(alsocalledAs(III),As(+3),andarsenite).Inwellwater,arsenicmaybepentavalent,trivalentoracombinationofboth.Labsrequirespecialsamplingpro-cedurestodeterminewhattypeandhowmuchofeachtypeofarsenicisinthewater.Checkwiththelabsinyourareatoseeiftheycanprovidethistypeofservice.

Reverseosmosis(RO)watertreatmentsystemsdonotremovetrivalentarsenicfromwaterverywell.ROsystemsareveryeffectiveatremovingpentavalentarsenic.Afreechlorineresidualwillrapidlyconverttrivalentarsenictopentavalentarsenic.Otherwatertreat-mentchemicalssuchasozoneandpotassiumpermanganatewillalsochangetrivalentarsenictopentavalentarsenic.Acombinedchlo-rineresidual(alsocalledchloramine)maynotconvertallthetrivalentarsenic.Ifyougetyourwaterfromapublicwaterutility,contacttheutilitytofindoutiffreechlorineorcombinedchlorineisusedinthewatersystem.

TheDrinkingWaterSystemPlusDeluxeisdesignedtoremovepentavalentarsenic.Itwillnotconverttrivalentarsenictopentavalentarsenic.Thesystemwastestedinalab.Underthoseconditions,thesystemreduced0.30mg/L(ppm)pentavalentarsenicto0.010mg/L(ppm)(theUSEPAstandardfordrinkingwater)orless.Theperformanceofthesystemmaybedifferentatyourinstallation.Havethetreatedwatertestedforarsenictocheckifthesystemisworkingproperly.

YoumustperiodicallyreplacetheROcomponent*oftheDrinkingWaterSystemPlusDeluxetoensurethesystemwillcontinuetoremovepentavalentarsenic.ThecomponentidentificationandlocationswhereyoucanpurchasethecomponentarelistedinthisPerformanceDataSheet,theOwner’sManualandtheinstallationinstructionsforyoursystem.

Inmostdrinkingwatersources,theinorganicformofarsenictendstobemorepredominantthanorganicforms.Inorganicarsenicindrinkingwatercanexerttoxiceffectsafteracute(short-term)orchronic(long-term)exposure.Althoughacuteexposuresto highdosesofinorganicarseniccancauseadverseeffects,suchexposuresdonotoccurfrompublicwatersuppliesintheU.S.atthecurrentMCLof50 µg/L.EPA'sproposeddrinkingwaterregulationaddressesthelong-term,chroniceffectsofexposuretolowconcentrationsofinorganicarsenicindrinkingwater.Chroniceffectsatlowconcentrationsinclude:

•CancerEffects:skin,bladder,lungandprostatecancer•Non-cancerEffects:skin,pigmentationandkeratosis,(callus-likeskingrowthsseenearliestandmostoften),gastrointestinal,cardiovascular,hor-

monal(e.g.diabetes),hematological(e.g.anemia),pulmonary,neurological,immunological,reproductive/developmentalfunctions

Thecontaminationofadrinkingwatersourcebyarseniccanresultfromeithernaturalorhumanactivities.Arsenicisanelementthatoccursnaturallyinrocksandsoil,water,air,plantsandanimals.Volcanicactivity,theerosionofrocksandmineralsandforestfiresarenatu-ralsourcesthatcanreleasearsenicintotheenvironment.Althoughabout90percentofthearsenicusedbyindustryintheUnitedStatesisusedforwoodpreservativepurposes,arsenicisalsousedinpaints,drugs,sedforwsedforw dyes,soaps,metalsandsemi-conductors.Burningfossilfuelsandwastes,paperproduction,glassmanufacturing,cementmanufacturing,miningandsmeltingcanalsoreleasearsenic.Whilearseniccannolongerbeusedinmakingpesticides,weedkillersandembalmingfluids,theAgencyisawarethatpriortothisbanthesesubstanceshavecontributedtodrinkingwatercontamination.

*SeeWarrantycoverageonpage2.

PERFORMANCE DATA SHEETPERFORMANCE DATA SHEETKinetico Drinking Water System

Plus Deluxe Models

KineticoIncorporated10845KinsmanRoad,Newbury,Ohio44065 440-564-9111 Rev10/05ProductNo.11355A

7

KineticoDrinkingWaterSystemPlusDeluxemodelswillreducethelevelsofcertainsubstancesindrinkingwater.Thesesubstancesarenotnecessarilyinyourwater.Becausewemaketheseclaims,theattachedinformationwascompiledtohelpyoubetterunderstandhowtheseproductswillperforminyourhome.

ContaminantreductiontestswereconductedbyNSFInternationalinaccordancewiththetestingprotocolsoftheUnitedStatesEnvironmentalProtectionAgency(USEPA).Givencertaininfluentlevels,theKineticoDrinkingWaterPlusDeluxewillreducethecontaminantlevelsbelowthosesetbytheUSEPA.TheseproductsconformtotheDrinkingWaterStandardsofyourstate.Ifyouwouldlikemoreinformation,contactyourauthorizedKineticodealer.

Pleasesignbelowtoverifythatyou’vereadandunderstandtheattachedinformation.

CONSUMER COPY

CONSUMER

Signature

Name (please print)

Address

City, State/Province, Zip/Postal Code

AUTHORIZED KINETICO DEALER REPRESENTATIVE

Signature

Salesperson's Name (please print)

Dealer's Name

Dealer's Address

City, State/Province, Zip/Postal Code

Dealer's Phone Number

PERFORMANCE DATA SHEETPERFORMANCE DATA SHEETKinetico Drinking Water System

Plus Deluxe Models

KineticoIncorporated10845KinsmanRoad,Newbury,Ohio44065 440-564-9111 Rev10/05ProductNo.11355A

8

KineticoDrinkingWaterSystemPlusDeluxemodelswillreducethelevelsofcertainsubstancesindrinkingwater.Thesesubstancesarenotnecessarilyinyourwater.Becausewemaketheseclaims,theattachedinformationwascompiledtohelpyoubetterunderstandhowtheseproductswillperforminyourhome.

ContaminantreductiontestswereconductedbyNSFInternationalinaccordancewiththetestingprotocolsoftheUnitedStatesEnvironmentalProtectionAgency(USEPA).Givencertaininfluentlevels,theKineticoDrinkingWaterPlusDeluxewillreducethecon-taminantlevelsbelowthosesetbytheUSEPA.TheseproductsconformtotheDrinkingWaterStandardsofyourstate.Ifyouwouldlikemoreinformation,contactyourauthorizedKineticodealer.

Pleasesignbelowtoverifythatyou’vereadandunderstandtheattachedinformation.

DEALER COPY

AUTHORIZED KINETICO DEALER REPRESENTATIVE

Signature

Salesperson's Name (please print)

Dealer's Name

Dealer's Address

City, State/Province, Zip/Postal Code

Dealer's Phone Number

CONSUMER

Signature

Name (please print)

Address

City, State/Province, Zip/Postal Code

State of CaliforniaDepartment of Health Services

Water Treatment DeviceCertificate Number

Date Issued: June 14, 2005

Trademark/Model Designation Replacement Elements

172305 -

Kinetico Drinking Water System Plus VX Deluxe withStandard Tank

Membrane #10501Sediment Prefilter #9309Carbon/Sediment Prefilter #9461VOC Postfilter #9307

Manufacturer: Kinetico Incorporated

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section116830 of the Health and Safety Code for the following health related contaminants:

CystsTurbidity

CadmiumFluorideLeadNitrate/Nitrite1

MTBEVOCs

Microbiological Contaminants and Turbidity Inorganic/Radiological Contaminants

Organic Contaminants

Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified forcyst reduction may be used on disinfected waters that may contain filterable cysts.1 Claims for arsenic reduction shall only be made on water supplies maintaining detectable residual free chlorine at thereverse osmosis (RO) system inlet. Water systems using an in-line chlorinator should provide a minimum of 1 minutechlorine contact time before the RO system.

N/ARated Service Capacity: 19.8 gpdRated Service Flow:

2This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite incombination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa(40 psig) or greater. A sampling and analysis test kit for nitrate is provided for checking the performance of this system.Frequent analysis is encouraged.

Conditions of Certification:

State of CaliforniaDepartment of Health Services

Water Treatment DeviceCertificate Number

Date Issued: June 14, 2005

Trademark/Model Designation Replacement Elements

172405 -

Kinetico Drinking Water System Plus VX Deluxe with 3 galQuick Flo

Membrane #10501Sediment Prefilter #9309Carbon/Sediment Prefilter #9461VOC Postfilter #9307

Manufacturer: Kinetico Incorporated

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section116830 of the Health and Safety Code for the following health related contaminants:

CystsTurbidity

CadmiumFluorideLeadNitrate/Nitrite1

MTBEVOCs

Microbiological Contaminants and Turbidity Inorganic/Radiological Contaminants

Organic Contaminants

Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified forcyst reduction may be used on disinfected waters that may contain filterable cysts.1 Claims for arsenic reduction shall only be made on water supplies maintaining detectable residual free chlorine at thereverse osmosis (RO) system inlet. Water systems using an in-line chlorinator should provide a minimum of 1 minutechlorine contact time before the RO system.

N/ARated Service Capacity: 35.5 gpdRated Service Flow:

2This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite incombination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa(40 psig) or greater. A sampling and analysis test kit for nitrate is provided for checking the performance of this system.Frequent analysis is encouraged.

Conditions of Certification:

State of CaliforniaDepartment of Health Services

Water Treatment DeviceCertificate Number

Date Issued: June 14, 2005

Trademark/Model Designation Replacement Elements

172505 -

Kinetico Drinking Water System Plus GX Deluxe withStandard Tank

Membrane #10501Sediment Prefilter #9309Carbon/Sediment Prefilter #9461Postfilter #9306

Manufacturer: Kinetico Incorporated

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section116830 of the Health and Safety Code for the following health related contaminants:

CystsTurbidity

CadmiumFluorideNitrate/Nitrite1

None

Microbiological Contaminants and Turbidity Inorganic/Radiological Contaminants

Organic Contaminants

Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified forcyst reduction may be used on disinfected waters that may contain filterable cysts.1This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite incombination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280kPa (40 psig) or greater. A sampling and analysis test kit for nitrate is provided for checking the performance of thissystem. Frequent analysis is encouraged.

N/ARated Service Capacity: 19.8 gpdRated Service Flow:

Conditions of Certification:

State of CaliforniaDepartment of Health Services

Water Treatment DeviceCertificate Number

Date Issued: June 14, 2005

Trademark/Model Designation Replacement Elements

172605 -

Kinetico Drinking Water System Plus GX Deluxe with 3 galQuick Flo

Membrane #10501Sediment Prefilter #9309Carbon/Sediment Prefilter #9461Postfilter #9306

Manufacturer: Kinetico Incorporated

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section116830 of the Health and Safety Code for the following health related contaminants:

CystsTurbidity

CadmiumFluorideNitrate/Nitrite1

None

Microbiological Contaminants and Turbidity Inorganic/Radiological Contaminants

Organic Contaminants

Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified forcyst reduction may be used on disinfected waters that may contain filterable cysts.1This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite incombination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280kPa (40 psig) or greater. A sampling and analysis test kit for nitrate is provided for checking the performance of thissystem. Frequent analysis is encouraged.

N/ARated Service Capacity: 35.5 gpdRated Service Flow:

Conditions of Certification:

State of CaliforniaDepartment of Health Services

Water Treatment DeviceCertificate Number

Date Issued: June 14, 2005

Trademark/Model Designation Replacement Elements

157705 -

Kinetico Drinking Water System Plus GX Deluxe with 1 galQuick Flo

Membrane #10501Sediment Prefilter #9309 orCarbon/Sediment Prefilter #9461Postfilter #9306

Manufacturer: Kinetico Incorporated

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section116830 of the Health and Safety Code for the following health related contaminants:

CystsTurbidity

CadmiumFluorideNitrate/Nitrite1

None

Microbiological Contaminants and Turbidity Inorganic/Radiological Contaminants

Organic Contaminants

Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified forcyst reduction may be used on disinfected waters that may contain filterable cysts.1 This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite incombination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280kPa (40 psig) or greater. A sampling and analysis test kit for nitrate is provided for checking the performance of thissystem. Frequent analysis is encouraged.

not applicableRated Service Capacity: 32.5 gpdRated Service Flow:

Conditions of Certification:

State of CaliforniaDepartment of Health Services

Water Treatment DeviceCertificate Number

Date Issued: June 14, 2005

Trademark/Model Designation Replacement Elements

157805 -

Kinetico Drinking Water System Plus VX Deluxe with 1 galQuick Flo

Membrane #10501Sediment Prefilter #9309 orCarbon/Sediment Prefilter #9461VOC Postfilter #9307

Manufacturer: Kinetico Incorporated

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section116830 of the Health and Safety Code for the following health related contaminants:

CystsTurbidity

CadmiumFluorideLeadNitrate/Nitrite1

MTBEVOCs

Microbiological Contaminants and Turbidity Inorganic/Radiological Contaminants

Organic Contaminants

Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified forcyst reduction may be used on disinfected waters that may contain filterable cysts.1This system is acceptable for treatment of influent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite incombination measured as N and is certified for nitrate/nitrite reduction only for water supplies with a pressure of 280kPa (40 psig) or greater. A sampling and analysis test kit for nitrate is provided for checking the performance of thissystem. Frequent analysis is encouraged.

500 galRated Service Capacity: 32.5 gpdRated Service Flow:

Conditions of Certification: