Fire-Rated Glass

41
Fire-Rated Glass Fire-Resistive Fire-Protective Pyrobel PyroDoors™ PyroFrames™ StileLite PyroGuard Pyran® Platinum New Wire

Transcript of Fire-Rated Glass

Fire-Rated GlassFire-Resistive

Fire-Protective

Pyrobel PyroDoors™ PyroFrames™ StileLite

PyroGuardPyran® Platinum New Wire

Pyrobel 45

• Manufactured by AGC for 45 minute fire rating with hose stream

• Multi-laminated glass with intumescent interlayers

• Designated on drawings and in specifications as Pyrobel 45

• Tested for use as door lites and 48” x 96” fixed lites in accordance with ASTM E119, NFPA 80, NFPA 257, NFPA 252, UL 9, UL 10B, and UL 10C

• Tested to ANSI Z97.1 and CPSC 16CFR 1201 to meet maximum safety ratings

• Available for standard steel door and frame assemblies with 5/8” stops

• Available with additional lite for decorative, patterned, or painted appearance

• For use in interior and exterior applications

• U.S. fabrication for fast delivery

Features & Benefits

Width Height Max. Sq. In. Stop Height ListingDoors 58 3/4” 58 3/4” 2747” 5/8” Intertek/WHI

Windows and Borrowed Lites

96” 96” 4608” 5/8” Intertek/WHI

Sidelites 96” 96” 4608” 5/8” Intertek/WHI

Maximum Glazing Sizes (ClearView)

For more information, please contact [email protected].

General Characteristics

Interior Exterior Insulated Exterior

Usage Interior Ext. below 120°F, above -20°F

Ext. above 120°F, below -20°F

Thickness 5/8” (16mm) -0/+1.5mm 3/4” (20mm) +/-1mm 1 1/4” (34mm) +/-2mm

Weight/sq.ft. 8.2 lbs (40kg/sq.m) 9.8 lbs (48kg/sq.m) 13.12 lbs (64kg/sq.m)

Light transmission 85% 83% 74%

Sound reduction Rw=39 dB Rw=40 dB Rw=42 dB

Safety rating CPSC 16CFR1201 Cat. II 400 ft. lbs. ANSI Z97.1

Fire rating 45 minutes

R-value 1.09 1.14 1.89

U-value 0.915 0.881 0.528

Product Guidelines

LISTINGSTesting completed by Intertek/Warnock-Hersey and UL

LABELINGAll products are labeled bearing the manufacturers name, testing laboratory, rating and safety standards.

INSTALLATIONAll systems require 1/4” x thickness of glass x 3” calcium silicate setting blocks placed at sill quarter points. Each lite of Pyrobel must be inspected prior to installation for damage including review of edge protecting tape. (DO NOT INSTALL GLASS THAT HAS BEEN DAMAGED.) Pyrobel must be glazed with 1/8” x 1/2” closed cell foam glazing tape. Exterior glazing must have PVB side facing to exterior side. Refer to shop drawings for final assembly requirements.

STORAGE AND HANDLINGStore in a dry, ventilated location, not exposed to solar radiation at temperatures not to exceed -20°F or 120°F. Always maintain glass in a vertical position with back slightly inclined at 6-10°.

QUALITY STANDARDPyrobel products are specially prepared products designed to prevent the expansion of fire. Thus, the specific optical quality should not be compared to single float or laminated PVB glazing. Consult GGI for specific acceptable quality standards.

GUARANTEEThe manufacturer, AGC Flat Glass Europe, guarantees the characteristics of Pyrobel for a period of 5 years from date of delivery. Due to the nature of its interlayers, Pyrobel may develop some minor im-perfections such as small bubbles or a slight distortion which will not affect the free vision through the glazing or fire performance. A variation of up to 5% of light transmission or haze shall not be considered a defect. This guarantee is for replacement of glass only. Any other costs associated with the removal or replacement of defective units is not the responsibility of the manufacturer. The guarantee shall apply only to glass handled, transported, stored and installed in accordance with normal procedures.

For more information, please contact [email protected].

Pyrobel 60

• Manufactured by AGC for 60 minute fire rating with hose stream

• Multi-laminated glass with intumescent interlayers

• Available in butt-glazed assembly*

• Designated on drawings and in specifications as Pyrobel 60

• Tested in accordance with ASTM E119, NFPA 80, NFPA 252, NFPA 257, UL 9, UL 10B, UL 10C and UL 263 as a transparent wall assembly using StileLite™ or GGI-KwicKap™ or GGI PyroFrames™

• Tested to ANSI Z97.1 and CPSC 16CFR 1201 to meet maximum safety ratings

• Available for use in door vision lite assemblies with 5/8” stop height

• Available with additional lite for decorative, patterned, or painted appearance

• For use in interior and exterior applications

• U.S. fabrication for fast delivery

Features & Benefits

Width Height Max. Sq. In. Stop Height ListingDoors 87 5/8” 87 5/8” 3855 5/8” Intertek/WHI

PyroFrames™ 86 5/8” 86 5/8” 3833 5/8” Intertek/WHI

KwicKap™ *87 5/8” *87 5/8” *3855 1 1/4” Intertek/WHI & UL

Vision 60™ *48” *96” *4608 5/8” Intertek/WHI

StileLite 60™ 93” 93” 4487 5/8” Intertek/WHI

Maximum Glazing Sizes (ClearView)

For more information, please contact [email protected].

General CharacteristicsInterior Exterior Insulated Exterior

Usage Interior Ext. below 120°F, above -20°F

Ext. above 120°F, below -20°F

Thickness 1” (25mm) +/-2mm 1 1/4” (29mm) +/-2mm 1 3/4” (45mm) +/-2mm

Weight/sq.ft. 12.3 lbs (60kg/sq.m) 13.94 lbs (68kg/sq.m) 17 lbs (83kg/sq.m)

Light transmission 81% 80% 71%

Sound reduction Rw=42 dB Rw=43 dB Rw=44 dB

Safety rating CPSC 16CFR1201 Cat. II 400 ft. lbs. ANSI Z97.1

Fire rating 60 minutes

R-value 1.14 1.16 2.18

U-value 0.881 0.862 0.458

Maximum structural load performance (wind load–ASTM E330) of Pyrobel-60-25 is 1119.1 lbs./sq. ft.

Product Guidelines

LISTINGS

Testing completed by Intertek/Warnock-Hersey and UL

LABELING

All products are labeled bearing the manufacturers name, testing laboratory, rating and safety standards.

INSTALLATION

All systems require 1/4” x thickness of glass x 3” calcium silicate setting blocks placed at sill quarter points. Each lite of Pyrobel must be inspected prior to installation for damage including review of edge protecting tape. (DO NOT INSTALL GLASS THAT HAS BEEN DAMAGED.) Pyrobel must be glazed with 1/8” x 1/2” closed cell foam glazing tape. Exterior glazing must have PVB side facing to exterior side.Refer to shop drawings for final assembly requirements.

STORAGE AND HANDLING

Store in a dry, ventilated location, not exposed to solar radiation at temperatures not to exceed -20°F or 120°F. Always maintain glass in a vertical position with back slightly inclined at 6-10°.

QUALITY STANDARD

Pyrobel products are specially prepared products designed to prevent the expansion of fire. Thus, the specific optical quality should not be compared to single float or laminated PVB glazing. Consult GGI for specific acceptable quality standards.

GUARANTEE

The manufacturer, AGC Flat Glass Europe, guarantees the characteristics of Pyrobel for a period of 5 years from date of delivery. Due to the nature of its interlayers, Pyrobel may develop some minor imperfections such as small bubbles or a slight distortion which will not affect the free vision through the glazing or fire performance. A variation of up to 5% of light transmission or haze shall not be considered a defect. This guarantee is for replacement of glass only. Any other costs associated with the removal or replacement of defective units is not the responsibility of the manufacturer. The guarantee shall apply only to glass handled, transported, store and installed in accordance with normal procedures.

For more information, please contact [email protected].

Pyrobel 90

• Manufactured by AGC for 90 minute fire rating with hose stream

• Multi-laminated glass with intumescent interlayers

• Designated on drawings and in specifications as Pyrobel 90

• Tested in accordance with ASTM E119, NFPA 80, NFPA 252, NFPA 257, UL 9, UL 10B, UL 10C and UL 263 as a transparent wall assembly using GGI-PyroFramesTM or GGI-KwicKapTM and in GGI-PyroDoorsTM

• Tested to ANSI Z97.1 and CPSC 16CFR 1201 to meet maximum safety ratings

• Available for standard steel door vision lite assemblies with 5/8” stop height

• Available with additional lite for decorative, patterned, or painted appearance

• For use in interior and exterior applications

• U.S. fabrication for fast delivery

Features & Benefits

Width Height Max. Sq. In. Stop Height ListingPyroDoors™ 39 3/4” 87 5/8” 3492 5/8” Intertek/WHI

PyroFrames™ 87 5/8” 87 5/8” 3833 5/8” Intertek/WHI

KwicKapTM 87 5/8” 87 5/8” 3528 5/8” Intertek/WHI

Vision Lites 36” 61” 2196 5/8” Intertek/WHI

Maximum Glazing Sizes (ClearView)

For more information, please contact [email protected].

General CharacteristicsInterior Exterior Insulated Exterior

Usage Interior Ext. below 120°F, above -20°F

Ext. above 120°F, below -20°F

Thickness 1 3/8” (35mm) +/-2mm 1 1/2” (37mm) +/-2mm 2” (50mm) +/-2mm

Weight/sq.ft. 16.4 lbs (80kg/sq.m) 18 lbs (88kg/sq.m) 21 lbs (103kg/sq.m)

Light transmission 82% 81% 72%

Sound reduction Rw=43 dB Rw=44 dB Rw=46 dB

Safety rating CPSC 16CFR1201 Cat. II 400 ft. lbs. ANSI Z97.1

Fire rating 90 minutes

R-value 1.16 1.21 2.22

U-value 0.862 0.828 0.460

Maximum structural load performance (wind load–ASTM E330) of Pyrobel-90-37 is 512.4 lbs/sq.

Product Guidelines

LISTINGS

Testing completed by Intertek/Warnock-Hersey and UL

LABELING

All products are labeled bearing the manufacturers name, testing laboratory, rating and safety standards.

INSTALLATION

All systems require 1/4” x thickness of glass x 3” calcium silicate setting blocks placed at sill quarter points. Each lite of Pyrobel must be inspected prior to installation for damage including review of edge protecting tape. (DO NOT INSTALL GLASS THAT HAS BEEN DAMAGED.) Pyrobel must be glazed with 1/8” x 1/2” closed cell foam glazing tape. Exterior glazing must have PVB side facing to exterior side. Refer to shop drawings for final assembly requirements.

STORAGE AND HANDLING

Store in a dry, ventilated location, not exposed to solar radiation at temperatures not to exceed -20°F or 120°F. Always maintain glass in a vertical position with back slightly inclined at 6-10°.

QUALITY STANDARD

Pyrobel products are specially prepared products designed to prevent the expansion of fire. Thus, the specific optical quality should not be compared to single float or laminated PVB glazing. Consult GGI for specific acceptable quality standards.

GUARANTEE

The manufacturer, AGC Flat Glass Europe, guarantees the characteristics of Pyrobel for a period of 5 years from date of delivery. Due to the nature of its interlayers, Pyrobel may develop some minor imperfections such as small bubbles or a slight distortion which will not affect the free vision through the glazing or fire performance. A variation of up to 5% of light transmission or haze shall not be considered a defect. This guarantee is for replacement of glass only. Any other costs associated with the removal or replacement of defective units is not the responsibility of the manufacturer. The guarantee shall apply only to glass handled, transported, store and installed in accordance with normal procedures.

For more information, please contact [email protected].

Pyrobel 120Features & Benefits

Width Height Max. Sq. In. Stop Height Listing

PyroFrames™ 86 5/8” 86 5/8” 3833 5/8” Intertek/WHI

StileLite300 94” 94” 4434 5/8” Intertek/WHI & UL

KwicKap™ *100 7/8” *100 7/8” *4434 11/4” UL

Butt-Glazed Panel 40” 114” 4560 11/4” UL

Maximum Glazing Sizes (ClearView)

For more information, please contact [email protected]

• Manufactured by AGC for 120 minute fire rating with hose stream

• Multi-laminated glass with intumescent interlayers

• Available in butt-glazed assembly*

• Designated on drawings and in specifications as Pyrobel 120

• Tested in accordance with ASTM E119, NFPA 80, NFPA 252, NFPA 257, UL 9, UL 10B, UL 10C and UL 263 as a transparent wall assembly using GGI-PyroFramesTM or StileLite 300TM or GGI-KwickKapTM

• Tested to ANSI Z97.1 and CPSC 16CFR 1201 to meet maximum safety ratings

• Available for standard steel door vision lite assemblies with 5/8” stop height

• Available with additional lite for decorative, patterned, or painted appearance

• Meets maximum performance requirements of ASTM C1629 Hard Body Impact testing

• ASTM C1629 Hard Body impact Classification Level 3 for materials; soft Body Impact Classification Level 2 for the Assembly as required by NYBC

General Characteristics

Interior Exterior Insulated Exterior

Usage Interior Ext. below 120°F, above -20°F

Ext. above 120°F, below -20°F

Thickness 2 1/8” (53mm) +3/-1mm 2 5/16” (57mm) +3/-1mm 2 3/4” (70mm) +3/-1mm

Weight/sq.ft. 24.6 lbs (120kg/sq.m) 26.2 lbs (128kg/sq.m) 30 lbs (146kg/sq.m)

Light transmission 71% 70% Varies

Sound reduction Rw=46 dB Rw=47 dB Varies

Safety rating CPSC 16CFR1201 Cat. II 400 ft. lbs. ANSI Z97.1

Fire rating 120 minutes

R-value 1.18 1.21 Varies

U-value 0.845 0.828 Varies

Maximum structural load performance (wind load–ASTM E330) of Pyrobel 120 is 512.4 lbs/sq. ft.

Product Guidelines

LISTINGS

Testing completed by Intertek/Warnock-Hersey and UL

LABELING

All products are labeled bearing the manufacturers name, testing laboratory, rating and safety standards.

INSTALLATION

All systems require 1/4” x thickness of glass x 3” calcium silicate setting blocks placed at sill quarter points. Each lite of Pyrobel must be inspected prior to installation for damage including review of edge protecting tape. (DO NOT INSTALL GLASS THAT HAS BEEN DAMAGED.) Pyrobel must be glazed with 1/8” x 1/2” closed cell foam glazing tape. Exterior glazing must have PVB side facing to exterior side.Refer to shop drawings for final assembly requirements.

STORAGE AND HANDLING

Store in a dry, ventilated location, not exposed to solar radiation at temperatures not to exceed -20°F or 120°F. Always maintain glass in a vertical position with back slightly inclined at 6-10°.

QUALITY STANDARD

Pyrobel products are specially prepared products designed to prevent the expansion of fire. Thus, the specific optical quality should not be compared to single float or laminated PVB glazing. Consult GGI for specific acceptable quality standards.

GUARANTEE

The manufacturer, AGC Flat Glass Europe, guarantees the characteristics of Pyrobel for a period of 5 years from date of delivery. Due to the nature of its interlayers, Pyrobel may develop some minor imperfections such as small bubbles or a slight distortion which will not affect the free vision through the glazing or fire performance. A variation of up to 5% of light transmission or haze shall not be considered a defect. This guarantee is for replacement of glass only. Any other costs associated with the removal or replacement of defective units is not the responsibility of the manufacturer. The guarantee shall apply only to glass handled, transported, stored and installed in accordance with normal procedures.

For more information, please contact [email protected]

GGI-PyroFrames™• Narrow profile, roll-formed steel framing manufactured

for 45 to 120 minute fire rating applications with hose stream

• Designated on drawings and in specifications as GGI-PyroFrames™

• Tested in accordance with UL 263, ASTM E119, and NFPA 251 as a transparent wall assembly with Pyrobel glazing

• Available with narrow stile GGI-PyroDoors™

• Internal and external surface protection provided by Sendzimir galvanizing for maximum durability in combination with painted finishes

• Multiple profile options available, including stainless steel

• Fully weeped system with glazing gaskets

• Shear block construction can be supplied in KD bar lengths or fully fabricated

Features & Benefits

General Characteristics

For more information, please contact [email protected].

Profile materials:

-Mild steel to ST37-2 quality according to DIN 17100. (Equivalent to S235 JRG2 according to EN10025)-Stainless steel to 1.4301 & 1.4404 quality according to DIN 17100. (Equivalent to 304 & 316L to AISI standards)-Sendzimir galvanising of interior and exterior of profiles to 275g/m2 according to EN10142.

Cap materials:

-Aluminium alloy to eloxadisable ALMgSi0.5 according to DIN 1747 and DIN 17615. (Equivalent to 6063-T6 to BSEN573-3)

For more information, please contact [email protected].

Product Guidelines

LISTINGS

Testing completed by Intertek/ Warnock-Hersey

LABELING

All products are labeled bearing the manufacturers name, testing laboratory, rating and safety standards.

INSTALLATION

GGI-PyroFrames™ have been tested in combination with Pyrobel fire-resistive glazing and require ¼” x 3” calcium silicate setting blocks at quarter points. Refer to shop drawing setting conditions for final installation requirements.

STORAGE AND HANDLING

Store in a dry, ventilated location, not exposed to solar radiation at temperatures not to exceed -20°F or 120°F. Always maintain in original packaging until ready for use.

QUALITY STANDARD

Sendzimir galvanizing process uses a small amount of aluminum in the zinc bath and produces a coating with essentially no iron-zinc alloy. The process guarantees high resistance to oxidation and increased durability versus hot-dipped and electro-galvanizing processes.

GUARANTEE

The manufacturer guarantees the characteristics of GGI-PyroFrames™ for a period of 5 years from date of delivery.

This guarantee is for replacement only. Any other costs associated with the removal or replacement of defective parts or units is not the responsibility of the manufacturer. The guarantee shall apply only to materials transported, stored and installed in accordance with recommended procedures.

System fasteners:

-Zinc coated 1.4301 stainless steel according to DIN EN17440. (Equivalent to 304 quality to AISI standards)

System gaskets:

-Non cellular elastomer compound to DIN EN7863. (Equivalent to BS3734)Performance classifications according to EN13830 : 2003:-Water Intrusion Resistance 1650 Pa / Air Permeability >600 Pa / Sound Insulation up to 47 dB

GGI-PyroDoors™• Narrow profile, roll-formed steel doors and frames

manufactured for 20 to 90 minute fire rating applications with hose stream

• Designated on drawings and in specifications as GGI-PyroDoors™

• Tested in accordance with UL 10c, UBC 7-2 , NFPA 252, CAN4 S104 with Pyrobel glazing

• Available with narrow profile GGI-PyroFrames™

• Internal and external surface protection provided by Sendzimir galvanizing for maximum durability in combination with painted finishes

• Limits Temperature - Rise to 2500 F at 30 minutes

• A choice of concealed or surface mounted hinges and closers

• Non-rebated or rebated meeting stiles

• Standard panic bars and automatic operators available

• Fully fabricated door and frame assembly for ease of installation

Features & Benefits

General Characteristics

For more information, please contact [email protected].

Profile materials:

-Mild steel to ST37-2 quality according to DIN 17100. (Equivalent to S235 JRG2 according to EN10025)-Stainless steel to 1.4301 & 1.4404 quality according to DIN 17100. (Equivalent to 304 & 316L to AISI standards)-Sendzimir galvanising of interior and exterior of profiles to 275g/m2 according to EN10142.

For more information, please contact [email protected].

Product Guidelines

LISTINGS

Testing completed by Intertek/ Warnock-Hersey

LABELING

All products are labeled bearing the manufacturers name, testing laboratory, rating and safety standards.

INSTALLATION

GGI-PyroDoors™ have been tested in combination with Pyrobel fire-resistive glazing. Refer to shop drawing setting conditions for final installation requirements.

STORAGE AND HANDLING

Store in a dry, ventilated location, not exposed to solar radiation at temperatures not to exceed -20°F or 120°F. Always maintain in original packaging until ready for use.

QUALITY STANDARD

Sendzimir galvanizing process uses a small amount of aluminum in the zinc bath and produces a coating with essentially no iron-zinc alloy. The process guarantees high resistance to oxidation and increased durability versus hot-dipped and electro-galvanizing processes.

GUARANTEE

The manufacturer guarantees the characteristics of GGI-PyroDoors™ for a period of 5 years from date of delivery.

This guarantee is for replacement only. Any other costs associated with the removal or replacement of defective parts or units is not the responsibility of the manufacturer. The guarantee shall apply only to materials transported, stored and installed in accordance with recommended procedures.

System fasteners:

-Zinc coated 1.4301 stainless steel according to DIN EN17440. (Equivalent to 304 quality to AISI standards)

System gaskets:

-Non cellular elastomer compound to DIN EN7863. (Equivalent to BS3734)

-Water Intrusion Resistance 1650 Pa / Air Permeability >600 Pa / Sound Insulation up to 47 dB

StileLite™Frames & Doors

• 60-120 minute temperature rise hollow metal transparent wall systems

• 20-90 doors with temperature-rise option

• Unlimited number of framing modules up to 49-7/8” wide

• Visible glass area of each opening can be up to 3,916 sq. in., not exceeding 46-3/4” x 83-3/4”

• All frames 14 gauge steel

• Jamb size from 4-3/4” to 14” with 5/8” glass stops

• Tnemec factory painted finishes and powder coating available

• Can be manufactured from cold-rolled, galvanized, or No. 4 stainless steel

• Doors up to 48” wide (96” pairs) x 108” high

• Finishing options for doors include: wood grain stainable steel, plastic laminate, factory-finished wood

• Frames and doors comply with ASTM E119, NFPA 251, UL 263, and CANULC S101, and UL 10c

Features & Benefits

General Characteristics

For more information, please contact [email protected].

After extensive testing over the last 3 decades, Stiles has become a groundbreaking industry leader in developing hollow metal technology for fire rated doors, windows, sidelites, and storefront systems. Stiles pioneered uniquely modular 60 and 120 minute transparent wall systems tested in combination with Pyrobel fire-resistive glazing.

The maximum overall door and frame sizes that can be fire rated by Stiles are as follows:a) Frames: 174” X 144”b) Single Doors: 51” X 120”c) Door Pairs: 102” X 120”d) Transparent Wall System: No Size Limit

Product GuidelinesLISTINGS

Testing completed by Intertek / Warnock-Hersey and UL

LABELING

All products are labeled bearing the manufacturers name, testing laboratory, rating and safety standards.

INSTALLATION

StileLite™ frames and doors have been tested in combination with Pyrobel fire-resistive glazing and require ¼” x 3” calcium silicate setting blocks at quarter points. Refer to shop drawing setting conditions for final installation requirements

STORAGE AND HANDLING

Store in a dry, ventilated location, not exposed to solar radiation at temperatures not to exceed -20°F or 120°F. Always maintain in original packaging until ready for use.

QUALITY STANDARD

StileLite™ framing and doors conform to the Hollow Metal Manufacturer’s Association (HMMA) quality and performance standards.

GUARANTEE

The manufacturer guarantees the characteristics of their framing and doors for a period of 5 years from date of delivery.

This guarantee is for replacement only. Any other costs associated with the removal or replacement of defective parts or units is not the responsibility of the manufacturer. The guarantee shall apply only to materials transported, stored and installed in accordance with recommended procedures.

For more information, please contact [email protected].

SCHOTT PYRAN® Platinum

For more information, please contact [email protected].

• Fire-rated up to 90 minutes with required hose stream test

• Specially floated glass-ceramic does not require polishing

• Transparent and wireless

• Withstands thermal shock

• Approved for use with any standard fire-rated frame with the same rating

• Conforms to positive pressure test standards

• Environmentally-friendly glass-ceramic; produced without hazardous heavy metals arsenic and antimony

• Cradle to Cradle® Certified Silver by MBDC

• Meets Leed Innovation in Design requirements

• Qualifies for Environmentally Preferred Purchasing Program (EPP)

• Can be used to construct insulated glazing units

• Can be lightly sandblasted or delivered with surface-applied opacity film

• Available locally through GGI distributor network

Features & Benefits

General Characteristics• Thickness: 3/16” (5mm)• Weight: 2.5 lbs/ft²• Clear, No amber tint• Surface finish: Float glass quality• Maximum sheet sizes: Approximately 43” x 77”• Impact Rating: None (For applications requiring an impact-rated material

SCHOTT offers PYRAN® Platinum F and PYRAN® Platinum L products)

For more information, please contact [email protected].

Classified and labeled by Underwriters Laboratories, Inc. for the United States and Canada under File # R22036. All fire tests performed in accordance with UL 9, UL 10C, UBC 7-2 (1997), UBC 7-4 (1997), NFPA 257, NFPA 80, ASTM E2010-01, ASTM E2074-00, and ULC CAN4-S106.

Note: This product is not considered a barrier to radiant heat and has not met the ASTM E-119 or UL 263 test standards. For additional information: contact GGI, 101 Venture Way, Secaucus, NJ 07094 or call (800) 431-2042.

LabelingAfter cutting, each lite of PYRAN® Platinum fire-rated glass-ceramic shall be permanently labeled according to local building code requirements with product and manufacturers name, UL certification mark, fire-rating, etc.

Ratings in Minutes Location

Max. exposed area of glazing

(in²)

Max. width of exposed glazing (in)

Max. height of exposed glazing (in)

Min. depth of groove

(in)Groove

width (in)

Building code

marking

Up to 90 min

Transom lites, sidelites, windows

3,422 (23.7 ft2) 76 76 5/8 7/16, 3/8 OH-90

Storage and HandlingPYRAN® Platinum fire-rated glass-ceramic should be handled with care during transportation, storage, inspection, and installation. It should be stored in dry conditions only and needs to be stacked upright or at a slight angle. In addition, the panels must be separated by an appropriate material, such as soft pads made of cork, and the bottom edge must be supported along its entire length.

InstallationPYRAN® Platinum shall only be installed into fire-rated frame and window assemblies carrying the same rating. Each PYRAN® Platinum panel should be inspected carefully before installation, and any pieces visible edge or surface damage should be sorted out. All glazing components and the stop height must be chosen according to the PYRAN® Platinum UL classification. The panel must be placed on calcium silicate or hardwood setting blocks and glazed using PYRAN® Platinum classified glazing tape, such as closed cell PVC, Fiberfrax tape or Pemko FG3000S90. The installation of the framed unit must comply with the frame supplier’s instructions.

PYRAN® Platinum is a specially developed glass-ceramic that fulfills the fire protection rating requirements. The production process may create certain optical imperfections, such as bubbles or knots. Since these do not generally impair the transparency or the technical performance of the glass-ceramic, they do not represent cause for rejection or replacement.

Maintenance and CareTo maintain the aesthetics, it is important to keep the panel clean. A soft, clean, non-abrasive cloth and a mild soap, detergent, or non abrasive window cleaning solution is suitable for cleaning. After cleaning, rinse immediately with clean water and remove any excess water from the panel surface. Also, do not allow any metal or hard parts of the cleaning equipment to come in contact with the panel surface.

Notes

Failure to comply with any of the Labeling, Storage & Handling, Installation, and/or Maintenance & Care guidelines may result in a loss of warranty.

SCHOTT PYRAN® Platinum F

For more information, please contact [email protected].

• Fire-rated up to 90 minutes (up to 180 minutes in doors) with required hose stream test

• Specially-floated glass-ceramic with surface applied safety film - does not require surface polishing

• Transparent and wireless

• Withstands thermal shock

• Approved for use with any standard fire-rated frame with the same rating

• Conforms to positive pressure test standards

• Environmentally-friendly glass-ceramic; produced without hazardous heavy metals arsenic and antimony

• Cradle to Cradle® Certified Silver by MBDC

• Meets Leed innovation in Design Requirements

• Qualifies for Environmentally Preferred Purchasing Program (EPP)

• Can be used to construct insulated glazing units

• Can be lightly sandblasted or delivered with surface-applied opacity film

• Available locally through GGI distributor network

Features & Benefits

General Characteristics• Thickness: 3/16” (5mm)• Weight: 2.5 lbs/ft²• Clear, No amber tint• Surface: Float glass quality• Maximum sheet sizes: Approximately 51” x 99”• Impact Rating: ANSI Z97.1 (Class A) and CPSC 16 CFR1201 (Cat. l and ll)

For more information, please contact [email protected].

LabelingAfter cutting, each lite of PYRAN® Platinum F fire- and safety-rated glass-ceramic shall be permanently labeled according to local building code requirements with product and manufacturers name, UL certification mark, fire-rating, etc.

Ratings in Minutes Location

Max. exposed area of glazing

(in²)

Max. width of exposed glazing (in)

Max. height of exposed glazing (in)

Min. depth of groove

(in)Groove

width (in)

Building code

marking

Up to 90 min

Doors Non-Temp Ride 2,736 (19 ft2) 36 76 5/8 7/16, 3/8 D-H-

NT-90

Up to 180 min

Doors Temp Rise and Non-

Temp Rise100 (0.69 ft2) 12 33 1/2 7/16, 3/8 D-H-

NT-180

Up to 90 Min

Transom lites, sidelites, win-

dows3,422 (23.7 ft2) 76 76 5/8 7/16, 3/8 OH-90

Storage and HandlingPYRAN® Platinum F fire-rated glass-ceramic should be handled with care during transportation, storage, inspection, and installation. It should be stored in dry conditions only and needs to be stacked upright or at a slight angle. In addition, the panels must be separated by an appropriate material, such as acid-free tissue paper, and the bottom edge must be supported along its entire length.

InstallationPYRAN® Platinum F shall only be installed into fire-rated frame and window assemblies carrying the same rating. Each panel should be inspected carefully before installation, and any pieces with visible edge or surface damage should be sorted out. All glazing components and the stop height must be chosen according to the PYRAN® Platinum F UL classification. The panel must be placed on calcium silicate or hardwood setting blocks and glazed using PYRAN® Platinum F classified glazing tape, such as closed cell PVC, Fiberfrax tape or Pemko FG3000S90. The installation of the framed unit must comply with the frame supplier’s instructions.

PYRAN® Platinum F is a specially developed glass-ceramic that fulfills the fire and safety protection rating requirements. The production process may create certain optical imperfections, such as bubbles or knots. Since these do not generally impair the transparency or the technical performance of the glass-ceramic, they do not represent cause for rejection or replacement.

Maintenance and CareTo maintain the aesthetics, it is important to keep the panel clean. A soft, clean, non-abrasive cloth and a mild soap, detergent, or non abrasive window cleaning solution is suitable for cleaning. After cleaning, rinse immediately with clean water and remove any excess water from the panel surface. Also, do not allow any metal or hard parts of the cleaning equipment to come in contact with the panel surface.

Notes

Failure to comply with any of the Labeling, Storage & Handling, Installation, and/or Maintenance & Care guidelines may result in a loss of warranty.

Classified and labeled by Underwriters Laboratories, Inc. for the United States and Canada under File # R22036. All fire tests performed in accordance with UL 9, UL 10B, UL10C, UBC 7-2 (1997), UBC 7-4 (1997), NFPA 252, NFPA 257, NFPA 80, ULC CAN4-5104, and ULC Can4-5106.

Note: This product is not considered a barrier to radiant heat and has not met the ASTM E-119 or UL 263 test standards.

SCHOTT PYRAN® Platinum L

For more information, please contact [email protected].

• Fire-rated up to 90 minutes (up to 180 minutes in doors) with required hose stream test

• Laminated specially floated glass-ceramic does not require polishing

• Transparent and wireless

• Withstands thermal shock

• Approved for use with any fire-rated frame

• Conforms to positive pressure test standards

• Environmentally-friendly glass-ceramic; produced without hazardous heavy metals arsenic and antimony

• Cradle to Cradle® Certified Silver by MBDC

• Meets Leed Innovation in Design requirements

• Qualifies for Environmentally Preferred Purchasing Program (EPP)

• Can be used to construct insulated glazing units

• Can be lightly sandblasted or delivered with surface-applied opacity film

• Available locally through GGI distributor network

Features & Benefits

General Characteristics• Thickness: 3/8” (9mm)

• Weight: 4.0 lbs/ft²

• Clear, No amber tint

• Surface finish: Float glass quality

• Maximum sheet sizes: Approximately 43” x 77”

• Impact Rating: ANSI Z97.1 (Class A) and CPSC 16CFR1201 (Cat. l and ll)

• STC rating: Approximately 36 dB

For more information, please contact [email protected].

LabelingAfter cutting, each lite of PYRAN® Platinum L fire-and safety-rated glass-ceramic shall be permanently labeled according to local building code requirements with product and manufacturers name, UL certification mark, fire-rating, etc.

Ratings in Minutes Location

Max. exposed area of glazing

(in²)

Max. width of exposed glazing (in)

Max. height of exposed glazing (in)

Min. depth of groove

(in)Groove

width (in)

Building code

marking

Up to 90 min

Doors Non-Temp Rise 2,736 (19 ft2) 76 75 5/8 5/8, 1/2 D-H-

NT-90

Up to 180 min

Doors Temp Rise and Non-

Temp Rise100 (0.69 ft2) 12 33 1/2 5/8 D-H-

NT-180

Up to 90 Min

Transom lites, sidelites, windows

3,143 (21.8 ft2) 75 75 5/8 5/8 OH-90

Storage and HandlingPYRAN® Platinum L fire-rated glass-ceramic should be handled with care during transportation, storage, inspection, and installation. It should be stored in dry conditions only and needs to be stacked upright or at a slight angle. In addition, the panels must be separated by an appropriate material, such as soft pads made of cork, and the bottom edge must be supported along its entire length.

InstallationPYRAN® Platinum L shall only be installed into fire-rated frame and window assemblies carrying the same rating. Each PYRAN® Platinum panel should be inspected carefully before installation, and any pieces visible edge or surface damage should be sorted out. All glazing components and the stop height must be chosen according to the PYRAN® Platinum L product classification. The panel must be placed on calcium silicate or hardwood setting blocks and glazed using PYRAN® Platinum L classified glazing tape, such as closed cell PVC, Fiberfrax tape or Pemko FG3000S90. The installation of the framed unit must comply with the frame supplier’s instructions.

PYRAN® Platinum L is a specially developed glass-ceramic that fulfills fire-protection rating requirements. The production process may create certain optical imperfections, such as bubbles or knots. Since these do not generally impair the transparency or the technical performance of the glass-ceramic, they do not represent cause for rejection or replacement.glass-ceramic, they do not represent cause for rejection or replacement.

Maintenance and CareTo maintain the aesthetics, it is important to keep the panel clean. A soft, clean, non-abrasive cloth and a mild soap, detergent, or non abrasive window cleaning solution is suitable for cleaning. After cleaning, rinse immediately with clean water and remove any excess water from the panel surface. Also, do not allow any metal or hard parts of the cleaning equipment to come in contact with the panel surface.

Notes

Failure to comply with any of the Labeling, Storage & Handling, Installation, and/or Maintenance & Care guidelines may result in a loss of warranty.

Classified and labeled by Underwriters Laboratories, Inc. for the United States and Canada under File # R22036. All fire tests performed in accordance with UL 9, UL 10B, UL10C, UBC 7-2 (1997), UBC 7-4 (1997), NFPA 252, NFPA 257, NFPA 80, ULC Can4-5104, and ULC CAN4-5106.

Note: This product is not considered a barrier to radiant heat and has not met the ASTM E-119 or UL 263 test standards.

NEW WIRE by GGI

For more information, please contact [email protected].

• Meets impact safety standards ANSI Z97.1 Class A

• UL certified for fire-ratings of 20, 45, 60 and 90 minutes.

• Case quantity sheet sizes up to 48” by 100” in Diamond (misco) and Georgian (square) patterns available for distribution

• Locally available through GGI distributor network

Features & Benefits

• Handled with care when shipping to prevent damage to edges and filmed surface.

Small occlusions and process marks from the manufacturing process may be visible,

but do not affect the fire-rating or safety performance of the product.

• Store in a dry place.

• Thickness: Nominal 1/4” (6.8 mm)

• Weight: approximately 3.85 lbs. per square foot

• Visible Light Transmittance: Approximately 78%

Specifications

Installation

• Must be glazed into appropriate fire-rated framing.

• Appropriate glazing compounds, such as Fiberfrax tape, closed cell PVC and Pemko FG300S45, must be used.

• For interior applications, fire-rating will not be affected by which surface has the film

Storage and Handling

Warranty• 3-year limited warranty

For more information, please contact [email protected].

Rating Application

Max. exposed area of glazing

(in2)

Max. width of exposed glazing (in)

Max. height of exposed glazing (in)

Min. depth of groove

(in)

Groove width (in)

Building code marking

20, 30, and 45

min

Doorframe, window, sidelite/transom

with or w/o 2nd piece

of 1/4” thick tempered

glass

1296 54 54 5/8 1/2

D-H-NT-20, OH-20, D-H-NT-

30, OH-30, D-H-NT-45, OH-45

20 min. No Hose

Hollow metal door 3289 35 3/4 92 3/4 1/2 D-NH-NT-20

45 min. Transom light 3456 96 36 5/8 1/2 D-H-NT-45

45 min. Sidelite or window 4608 100 100 5/8 1/2 D-H-NT-45, OH-45

45 min. Hollow metal door 2856 34 84 5/8 1/2 D-H-NT45

90 min. Hollow metal door 552 12 46 5/8 1/2 D-H-NT-90

60 min. Wood door 960 12 80 5/8 1/2 D-H-NT-60

Pyroguard

For more information, please contact [email protected].

• Wire-free laminated glass• 7mm thickness for 20 minute applications without

hose stream• Intumescent interlayer provides protection against

radiant heat• Easy to cut, no edge taping needed• UV stability for interior and exterior applications• UL certified, ANSI Z97.1 Class B impact resistance• Cut-to-size available locally through GGI distributor

network• Case quantity available with sheet size of 62” x 109”

Features & Benefits

General Characteristics

Ratings in Minutes Location

Max. exposed area of glazing

(in2)

Max. width of exposed glazing (in)

Max. height of exposed glazing (in)

Min. depth of groove

(in)Groove

width (in)

Building code

marking

20 min NH Door Lites 1404 28 62 3/4 9/16 D-NH-NT-20

GGI-PYROFRAMESTM - JAMB

3 9/16"

3/16"

Pyrobel 60 / 120

3/16"

9/16"

3/8" 2 3/8"

GGI-PYROFRAMESTM - STRUCTURAL MULLION

3 9/16"

3/16"

Pyrobel 60 / 120

3/16"

9/16"

2 3/8"

GGI-PYROFRAMESTM - HEAD

9/16"

2 3/8"3

9/16

"

3/16

"

Pyr

obel

60

/ 120

3/16

"

9/16

"

GGI-PYROFRAMESTM - HORIZONTAL MULLION

2 3/8"

9/16

"

3/16

"

Pyro

bel 6

0 / 1

20

3/16

"

3 9/

16"

GGI-PYROFRAMESTM - SILL

9/16

"

3/16

"

Pyr

obel

60

/120

3/16

"

3 9/

16"

2 3/8"

GGI-PYRODOORSTM

- JAMB

2 3/

8"

Max

imum

3/8"

1 15

/16"

3/8"

1 15

/16"

13/1

6"

GGI-PYRODOORSTM - HEAD

3/8"

1 15/16"

1/2"

1 15/16"

13/16"

1 1/2"

2 3/8"

2 3/8"

1 1/2"

GGI-PYRODOORSTM - SILL

13/16"

1 15/16"

5/16"

2 3/

8”1

15/1

6” 3

/8”

13/

16”

1 15

/16”

GGI-PYRODOOR™GGI-PYROFRAME™CONNECTION

T14

1.87

5".6

25"

.625

"

.625

"

.938

".9

38"

.625

"

.625

"

DR

T14

1.87

5".6

25"

.063

"

.625

"

.938

"

1.93

8"

4.75

" - 1

4"

4.75

" - 1

4"4.

75" -

14"

4.75

" - 1

4"

DIS

TRIB

UTE

D B

Y G

GI

.625

" 1.

875"

.6

25"

Mul

lion

DR

T14

1.87

5"0.

625"

0.62

5"

0.62

5"

1.93

8"4.75

" -

14"

1.93

8"

1.87

5".6

25"

DR

T14

.625

"

.625

"

1.87

5".6

25"

.625

"

.625

"

T14

.625

".6

25"

.938

".9

38"

1.56

3"1.

563"

4.75

" - 1

4"4.

75" -

14"

1.87

5".6

25"

.063

".9

38"

1.56

3".6

25"

DR

T14

.625

"

4.75

" - 1

4"

4.75

" - 1

4"

.625

"1.

875"

.625

"

3.12

5"

4.75

" - 1

4"

Mul

lion

DIS

TRIB

UTE

D B

Y G

GI

101

VEN

TURE

WAY

SECA

UCU

S, N

J 07

094

Mod

ular

Con

nect

ion

STIL

ELIT

E 20

0 - 6

0 M

IN M

OD

ULA

R W

ALL

ASSE

MBL

Y

Doo

r / F

ram

eD

oor /

Sid

elite

Jam

b /

Hea

d

DO

OR

JAM

B CO

NN

ECTI

ON

3.50

0" M

IN

2.37

5"

JAM

B O

R H

EAD

CAP

2.37

5"

ANCH

OR

BOLT

BO

HO

RIZO

NTAL

MU

LLIO

NSI

LL

SETT

ING

BLO

CK

3.50

0" M

IN

1.62

5"2.

375"

VER

TICA

L M

ULLIO

N

2.37

5"

3.50

0" M

IN3.

500"

MIN

RETA

INER

W

ITH

CAP

RETA

INER

W

ITH

CAP

2 H

OU

R T

EMP

RISE

GLA

SS B

O2

HO

UR

TEM

P RI

SE GLA

SS B

O

RETA

INER

W

ITH

CAP

2 H

OU

R T

EMP

RISE

GLA

SS B

OD

OO

R

DO

OR

JAM

B

CAP

RETA

INER

CA

P

PYRO

BEL

120

DIS

TRIB

UTE

D B

Y G

GI

101

VEN

TUR

E W

AY

SEC

AU

CU

S, N

J 07

094

CAP

2.37

5"

ANCH

OR

BOLT

BO

3.50

0" M

IN

RETA

INER

W

ITH

CAP

PYRO

BEL

120

JAM

B O

R H

EAD

2.37

5"

3.50

0" M

IN

RETA

INER

W

ITH

CAP

PYRO

BEL

120

VERT

ICAL

MU

LLIO

N

1.62

5"2.

375"

3.50

0"MI

N

RETA

INER

W

ITH

CAP

PYRO

BEL 1

20

DOOR

DOOR

JA

MB

CAP

DO

OR

JAM

B CO

NN

ECTI

ON

3.500

" MIN

2.375

"

SILL

ANC

HOR

BOLT

BO

RETA

INER

CA

P

PYRO

BEL 1

20 CAP

SETT

ING

BLOC

K

APPE

NDI

X A

- 201

5 IB

C SE

CTIO

N 7

16 T

ABLE

S

Mar

king

Fire

-Rat

ed G

lazi

ng A

ssem

blie

s

Fire

Tes

tSta

ndar

dM

arki

ngD

efin

ition

ofM

arki

ngPr

oduc

ts a

dded

forr

efer

ence

AS

TM E

119

or U

L26

3W

M

eets

wal

l ass

embl

ycrit

eria

.P

yrob

el60

-120

NFP

A 2

57 o

r UL

9 O

HM

eets

fire

win

dow

ass

embl

ycr

iteria

in

clud

ing

the

hose

stre

amte

st.

Pyr

obel

45P

YR

AN

Pla

tinum

PY

RA

NP

latin

um F

PYR

AN P

latin

um L

GG

I NEW

WIR

E

NFP

A 2

52 o

r UL

10B

or U

L10

CD

H

T

Mee

ts fi

re d

oor a

ssem

blyc

riter

ia.

Mee

ts fi

re d

oor a

ssem

bly

“Hos

eS

tream

”te

st.

Mee

ts 4

50º F

tem

pera

ture

rise

crit

eria

for

30m

inut

es

Pyr

ogua

rd 2

0 P

yrob

el45

-120

PY

RA

N P

latin

um F

PY

RAN

Pla

tinum

LG

GI N

EW W

IRE

Pyr

obel

45-1

20

PY

RA

N P

latin

um F

PYR

AN P

latin

um L

GG

I NEW

WIR

E

Pyr

obel

45-

120

XXX

The

time

in m

inut

es o

f the

fire

resi

stan

ce

or f

ire p

rote

ctio

n ra

ting

of t

hegl

azin

gas

sem

bly

For S

I: °

C =

[(°F

) – 3

2]/1

.8.

The

follo

win

g pa

ges p

rovi

de p

rodu

ct re

fere

nces

bas

ed o

n ty

pica

l IBC

requ

irem

ents

. Pl

ease

co

nsul

t with

you

r loc

al A

utho

rity

Havi

ng Ju

risdi

cco

nfirm

cor

rect

pro

duct

app

lic.

IBC

RE

FE

RE

NC

E T

AB

LES

2015

Inte

rnat

iona

l Bui

ldin

g C

ode,

Inte

rnat

iona

l Cod

e C

ounc

il, In

c., W

ashi

ngto

n, D

.C.

Rep

rodu

ced

with

per

mis

sion

. All

right

s re

serv

ed. w

ww

.iccs

afe.

org

(con

nued

on

next

pag

e)

2015

IBC

Tabl

e 71

6.5

Ope

ning

Fire

Pro

tec

on A

ssem

blie

s, R

ang

s and

Mar

king

s

TYPE

OF

ASSE

MBL

Y RE

QU

IRED

W

ALL

ASSE

MBL

Y RA

TIN

G (H

RS.)

MIN

IMU

M

FIRE

DO

OR

AND

FIRE

SH

UTT

ER

ASSE

MBL

Y RA

TIN

G (H

RS.)

DOO

R VI

SIO

N

PAN

EL S

IZE

b

FIRE

RAT

ED

GLAZ

ING

MAR

KIN

G DO

OR

VISI

ON

PA

NEL

d

Prod

ucts

for D

oor

Visi

on

Pane

l add

ed fo

rre

fere

nce

MIN

IMU

M S

IDEL

ITE/

TRAN

SOM

AS

SEM

BLY

RATI

NG

(HRS

.) FI

RE R

ATED

GLA

ZIN

G M

ARKI

NG

SIDE

LITE

/TRA

NSO

M P

ANEL

Pr

oduc

tsfo

r Si

delit

e/Tr

anso

m

adde

d fo

rre

fere

nce

Fire

Prot

ectio

nFi

reR

esis

tanc

eFi

rePr

otec

tion

Fire

Res

ista

nce

Fire

wal

lsan

d

4 3

See

Not

e b

D-H

-W-2

40N

otP

erm

itted

4 N

otW

-240

Per

mitt

ed

3 3a

See

Not

e b

D-H

-W-1

80N

otP

erm

itted

3 N

otP

erm

itted

W-1

80

2 1-

1/2

100

sq.i

n

in.

= D

-H-9

0

>100

sq.

in.

=D-H

-W-9

0

Not

Per

mitt

ed2

Not

Per

mitt

edW

-120

Pyr

obel

120

fire

barr

iers

havi

nga

requ

ired

fire

resi

stan

cera

ting

grea

ter

than

1ho

ur

1-1/

21-

1/2

100

sq.i

n

in.

= D

-H-9

0

>100

sq.

in.

=D-H

-W-9

0

Not

Per

mitt

ed1-

1/2

Not

Per

mitt

edW

-90

Pyro

bel9

0

Enc

losu

res

for

shaf

ts,

inte

rior

exit

stai

rway

s

2 1-

1/2

100

sq.i

n

in.

= D

-H-9

0PY

RAN

Pla

tinum

F a

ndL

Not

Per

mitt

ed2

Not

Per

mitt

edW

-120

Pyr

obel

120

and

inte

rior

exit

ram

ps>1

00 s

q.in

.=

D-H

-T-9

0P

yrob

el90

orD

-H-T

-W-9

0

Hor

izon

tal

exits

infir

ew

alls

e

4 3

100

sq.i

n.

in.

= D

-H-1

80>1

00 s

q.in

.

D-H

-W-2

40

PYR

AN

Pla

tinum

F a

nd L

N

otP

erm

itted

4 N

otP

erm

itted

W-2

40

3 3

a10

0 sq

.in.

in.

= D

-H-1

80>1

00 s

q.in

.D

-H-W

-180

PYR

AN

Pla

tinum

F a

nd L

N

otP

erm

itted

3 N

otP

erm

itted

W-1

80

GG

I NEW

WIR

E

PYR

AN P

latin

um F

and

L

Pyro

bel 9

0

GG

I NEW

WIR

E

PYR

AN P

latin

um F

and

L

Pyro

bel 9

0

GG

I NEW

WIR

E

2015

Inte

rnat

iona

l Bui

ldin

g C

ode,

Inte

rnat

iona

l Cod

e C

ounc

il, In

c., W

ashi

ngto

n, D

.C.

Rep

rodu

ced

with

per

mis

sion

. All

right

s re

serv

ed. w

ww

.iccs

afe.

org

(con

nued

on

next

pag

e)

TYPE

OF

ASSE

MBL

Y RE

QU

IRED

W

ALL

ASSE

MBL

Y RA

TIN

G (H

RS.)

MIN

IMU

M

FIRE

DO

OR

AND

FIRE

SH

UTT

ER

ASSE

MBL

Y RA

TIN

G (H

RS.)

DOO

R VI

SIO

N

PAN

EL S

IZE

b

FIRE

RAT

ED

GLAZ

ING

MAR

KIN

G DO

OR

VISI

ON

PA

NEL

d

Prod

uct f

or D

oor V

isio

nPa

nel

adde

d fo

r ref

eren

ce

MIN

IMU

M S

IDEL

ITE/

TRAN

SOM

AS

SEM

BLY

RATI

NG

(HRS

.) FI

RE R

ATED

GLA

ZIN

G M

ARKI

NG

SIDE

LITE

/TRA

NSO

M P

ANEL

Pr

oduc

tsfo

r Si

delit

e/Tr

anso

m

adde

d fo

rre

fere

nce

Fire

Prot

ectio

nFi

reR

esis

tanc

eFi

rePr

otec

tion

Fire

Res

ista

nce

Fire

barr

iers

1 1

100

sq. i

nc

in.

GG

I NE

W W

IRE

PYR

AN P

latin

um F

and

L

Pyr

obel

60N

otP

erm

itted

1 N

otW

-60

Pyro

bel6

0

havi

nga

requ

ired

fire-

resi

stan

ce=

D-H

-60

ratin

g of

1ho

ur:

Enc

losu

res

for

shaf

ts,e

xit

acce

ssst

airw

ays,

exit

Per

mitt

edac

cess

ram

p,in

terio

rexi

tst

airw

ays,

>100

sq.

in.

inte

riore

xit

=D

-H-T

-60

ram

ps a

ndex

itor

pass

agew

ayD

-H-T

-W-6

0w

alls

.

Fire

Prot

ectio

n

Oth

erFi

reB

arrie

rs1

3/4

Max

imum

S

ize

Test

edD

-HG

GI N

EW W

IRE

Pyr

obel

45PY

RAN

Pla

tinum

Fan

dL

3/4

D-H

Pyr

obel

45G

GI N

EW

WIR

EP

YR

AN

Pla

tinum

Fan

dL

Fire

Par

titio

ns/

Cor

ridor

Wal

ls

1 1/

3b

Max

imum

S

ize

Test

edD

-20

Pyro

guar

d20

GG

I NEW

WIR

EP

YR

AN

Pla

tinum

Fan

dL

3/4b

D-H

-OH

-45

Pyr

obel

45G

GI N

EW

WIR

EP

YR

AN

Pla

tinum

Fan

dL

0.5

1/3

bM

axim

um

Siz

eTe

sted

D-2

0Py

rogu

ard

20G

GI N

EW

WIR

EPY

RAN

Plat

inum

F a

ndL

1/3

D-H

-OH

-20

Pyr

obel

45G

GI N

EW

WIR

EP

YR

AN

Pla

tinum

Fan

dL

Oth

erFi

reP

artit

ions

1 3/

4M

axim

um

Siz

eTe

sted

D-H

-45

Pyro

bel4

5G

GI N

EW W

IRE

PYR

ANPl

atin

um F

and

L3/

4D

-H-4

5

Pyr

obel

45G

GI N

EW

WIR

EP

YR

AN

Pla

tinum

Fan

dL

0.5

1/3

Max

imum

S

ize

Test

edD

-H-2

0Py

robe

l45

GG

I NE

W W

IRE

PYR

ANPl

atin

um F

and

L1/

3D

-H-2

0

Pyr

obel

45G

GI N

EW

WIR

EP

YR

AN

Pla

tinum

Fan

dL

2015

Inte

rnat

iona

l Bui

ldin

g C

ode,

Inte

rnat

iona

l Cod

e C

ounc

il, In

c., W

ashi

ngto

n, D

.C.

Rep

rodu

ced

with

per

mis

sion

. All

right

s re

serv

ed. w

ww

.iccs

afe.

org

TYPE

OF

ASSE

MBL

Y RE

QU

IRED

W

ALL

ASSE

MBL

Y RA

TIN

G (H

RS.)

MIN

IMU

M

FIRE

DO

OR

AND

FIRE

SH

UTT

ER

ASSE

MBL

Y RA

TIN

G (H

RS.)

DOO

R VI

SIO

N

PAN

EL S

IZE

b

FIRE

RAT

ED

GLAZ

ING

MAR

KIN

G DO

OR

VISI

ON

PA

NEL

d

Prod

uct f

or D

oor V

isio

nPa

nel

adde

d fo

r ref

eren

ce

MIN

IMU

M S

IDEL

ITE/

TRAN

SOM

AS

SEM

BLY

RATI

NG

(HRS

.) FI

RE R

ATED

GLA

ZIN

G M

ARKI

NG

SIDE

LITE

/TRA

NSO

M P

ANEL

Pr

oduc

tsfo

r Si

delit

e/Tr

anso

m

adde

d fo

rre

fere

nce

Fire

Prot

ectio

nFi

reR

esis

tanc

eFi

rePr

otec

tion

Fire

Res

ista

nce

Ext

erio

rWal

ls

3 1-

1/2

100

sq. i

n.b

in.

= D

-H-9

0

>100

sq.

in.

=D-H

-W-9

0

PYR

AN P

latin

um F

and

L

Pyr

obel

90

Not

Per

mitt

ed3

Not

Per

mitt

edW

-180

2 1-

1/2

100

sq. i

n.b

in.

= D

-H-9

0

>100

sq.

in.

=D-H

-W-9

0

PYR

AN P

latin

um F

and

L

Pyr

obel

90

Not

Per

mitt

ed2

Not

Per

mitt

edW

-120

Pyr

obel

120

Fire

Prot

ectio

n

1 3/

4M

axim

um

Siz

eTe

sted

D-H

-45

Pyro

bel 4

5

PYR

ANPl

atin

um F

and

L3/

4D

-H-4

5

Pyr

obel

45

PY

RA

N P

latin

umF

and

L

Sm

oke

Bar

riers

Fire

Prot

ectio

n

1 1/

3M

axim

um

Siz

eTe

sted

D-2

0Py

rogu

ard

20

PYR

ANPl

atin

um F

and

L3/

4D

-H-O

H-4

5

Pyr

obel

45

PY

RA

N P

latin

umF

and

LFo

r SI:

1 sq

uare

inch

– 6

45.2

mm

a.Tw

odo

ors,

each

with

a fi

repr

otec

tion

ratin

gof

1-1

/2ho

urs,

inst

alle

don

oppo

site

side

sof

the

sam

eop

enin

gin

a fi

rew

all,

shal

lbe

deem

edeq

uiva

lent

infir

epr

otec

tion

ratin

gto

one

3-h

our f

iredo

or.

b.Fi

re re

sist

ance

rate

d gl

azin

g te

sted

to A

STM

E11

9 in

acc

orda

nce

with

Sec

tion

716.

2 sh

all b

e pe

rmitt

ed, i

n th

e m

axim

um s

ize

test

ed.

c.E

xcep

t whe

reth

ebu

ildin

gis

equi

pped

thro

ugho

ut w

ithan

auto

mat

icsp

rinkl

eran

dth

efir

e-ra

ted

glaz

ing

mee

tsth

ecr

iteria

esta

blis

hed

inS

ectio

n71

6.5.

5.d.

Und

erth

eco

lum

nhe

adin

g“F

irera

ted

glaz

ing

mar

king

door

vis

ion

pane

l”, W

refe

rsto

the

fire-

resi

stan

ce ra

ting

ofth

egl

azin

g,no

tthe

fram

e.e.

See

Sect

ion

716.

5.8.

1.2.

1.

2015

Inte

rnat

iona

l Bui

ldin

g C

ode,

Inte

rnat

iona

l Cod

e C

ounc

il, In

c., W

ashi

ngto

n, D

.C.

Rep

rodu

ced

with

per

mis

sion

. All

right

s re

serv

ed. w

ww

.iccs

afe.

org

2015

IBC

Tabl

e 71

6.6

Fire

Win

dow

Ass

embl

y Fi

re P

rote

con

Ra

ngs

TYPE

OF

WAL

L ASS

EMBL

Y RE

QU

IRED

WAL

L AS

SEM

BLY

RATI

NG

(hou

rs)

MIN

IMU

M F

IRE

WIN

DO

W

ASSE

MBL

Y RA

TIN

G (h

ours

)

FIRE

RAT

ED

GLA

ZIN

G

MAR

KIN

G

Prod

ucts

add

ed fo

rref

eren

ce

Inte

rior w

alls

All

NPa

W-X

XXb

Fire

wal

ls Fi

re b

arrie

rs

>1N

PaW

-XXX

b

1N

PaW

-XXX

b

Inci

dent

al u

se

1 ¾

O

H-45

or W

-60

area

s (70

7.3.

7),

Mix

ed o

ccup

ancy

se

para

ons(

707.

3.9)

Fire

Par

ons

1 ¾

O

H-45

or W

-60

0.5

1/3

OH-

20 o

r W-3

0

Smok

e Ba

rrie

r 1

¾

OH-

45 o

r W-6

0

Pyro

bel 6

0-12

0

Pyro

bel 4

5 or

60

If le

ss th

an 2

5% o

f the

wal

l are

a: P

yrob

el 4

5, G

GI

NEW

WIR

E or

Non

-Film

ed W

ired

Glas

s, PY

RAN

Pl

am

, PYR

AN P

lam

F o

r L

Pyro

bel 4

5 or

60

If le

ss th

an 2

5% o

f the

wal

l are

a: P

yrog

uard

20,

GGI

N

EW W

IRE

or N

on-F

ilmed

Wire

d Gl

ass,

PYRA

N

Pla

m, P

YRAN

Pl

num

F o

r L

Exte

rior w

alls

>1

1-1/

2O

H-90

or W

-XXX

b

1 ¾

OH-

45 o

r W-6

0

0.5

1/3

OH-

20 o

r W-3

0

Pyro

bel 9

0 or

120

N

ote

open

ing

limits

per

Tab

le 7

05.8

Pyro

bel 4

5 or

60

GGI

NEW

WIR

E or

Non

-Film

ed w

ired

Glas

s, PY

RAN

Pl

am

, PYR

AN P

lam

F o

r L

Not

e op

enin

g lim

its p

er T

able

705

.8:

Part

y w

all

All

NP

Not

App

licab

le

NP

– N

otP

erm

itted

a.N

ot p

erm

itted

exc

ept f

ire re

sist

ance

rate

d gl

azin

g as

sem

blie

s te

sted

to A

STM

E11

9 or

UL

263,

as

spec

ified

in S

ectio

n71

6.2.

b.X

XX

= T

he fi

re ra

ting

dura

tion

perio

d in

min

utes

, whi

ch s

hall

be e

qual

to th

e fir

e re

sist

ance

ratin

g re

quire

d fo

r the

wal

lass

embl

y.

2015

Inte

rnat

iona

l Bui

ldin

g C

ode,

Inte

rnat

iona

l Cod

e C

ounc

il, In

c., W

ashi

ngto

n, D

.C.

Rep

rodu

ced

with

per

mis

sion

. All

right

s re

serv

ed. w

ww

.iccs

afe.

org