DRAINAGE REPORT - City of East Orange
-
Upload
khangminh22 -
Category
Documents
-
view
0 -
download
0
Transcript of DRAINAGE REPORT - City of East Orange
TABLE OF CONTENTS
Page No.
I. Summary………………………………………………….…….….1
II. Runoff Rate Reductions Performance……………………….......2
III. Proposed Water System…………………………………………...2
IV. Proposed Sanitary Sewer System………………………….……...3
V. Conclusion…………………………………………………….…...4
APPENDIX
• NRCS Web Soil Survey
• Runoff Curve Number (CN) Calculations – Existing
• Runoff Curve Number (CN) Calculations – Proposed
• Hydrograph Summary Reports – Existing and Proposed Conditions 2 yr. & 10 yr.
• Hydrograph Summary Reports – Existing and Proposed Conditions 100 yr.
• Stormwater Collection System Calculations
• Drainage Area Maps
• Surface infiltration Testing Report (By Dynamic Earth, LLC) (Under separate cover)
• Capacity of Circular Pipe Flowing ½ Full
KSH N. Oraton Development, LLC - 1 - December 2020
DEC# 3421-99-001 Last Revised February 2021
I. Summary This Drainage Statement & Water and Sanitary Sewer Engineer’s Report has been prepared to define
and analyze the stormwater drainage conditions as well as the water and sewer utility connections
that would occur as a result of the redevelopment of Block 243, Lot 1 as shown on the City of East
Orange Tax Map Sheet No. 24, located in the City of East Orange, Essex County, New Jersey. The
subject site consists of 0.305 acres (13,296 SF) and is located on North Oraton Parkway and Freeway
Drive East.
Under existing conditions, the site is undeveloped with gravel and surface vegetation. The proposed
project consists of developing the property with a 5-story multi-family apartment building with parking
provided beneath the ground floor. Additional site improvements will include lighting, landscaping,
grading, driveways, and other associated site amenities. The new development proposes to reduce the
impervious coverage on site by approximately 13.1% (1,737 SF).
The project consists of less than one (1) acre of disturbance and will not increase the impervious
coverage on-site by ¼ acre or more. Therefore, the proposed project does not meet the definition of a
‘major development’ and is not subject to the NJDEP Stormwater Management Rules (NJAC 7:8).
Furthermore, the proposed development does not increase the existing impervious surfaces on site;
therefore, it is not subject to the New Jersey Standards for Soil Erosion and Sediment Control runoff
rate reduction requirements.
The stormwater runoff is drains via sheet flow to the north of the property towards Route 280 and the
existing stormwater conveyance system located within the intersection of Route 280 and North Oraton
Parkway. Please reference the enclosed Boundary and Topographic Survey, prepared by Dynamic
Survey, LLC, dated 04/29/2020, last revised 10/27/2020, indicating the existing conditions of the
site for additional information.
For the stormwater analysis, the existing gravel surfaces onsite were modeled as impervious surfaces
in accordance with the NJDEP based on the surface infiltration testing and field study that was
conducted. Please refer to the Surface Infiltration Testing Report, prepared by Dynamic Earth, LLC,
dated November 13, 2020 for reference.
KSH N. Oraton Development, LLC - 2 - December 2020
DEC# 3421-99-001 Last Revised February 2021
The stormwater drainage for the proposed site has been designed to maintain existing runoff patterns
as feasible. The proposed roof leader system routes stormwater from the roof of the proposed building
to the proposed inlets located within the parking lot. The stormwater within the parking lot and
subterranean parking area will be collected by the proposed trench drains and inlets that will be
ultimately drain into the existing stormwater conveyance system within Freeway Drive East.
Stormwater runoff from the landscaped areas on the remainder of the site will drain via sheet flow
towards the north of the site.
II. Runoff Rate Reduction Performance
As noted above, a majority of the stormwater runoff from the proposed development discharges into
the existing stormwater conveyance system located within Freeway Drive East. Due to the
improvements associated with the proposed development, the total runoff discharging to this existing
stormwater conveyance system decreases for the two (2), ten (10) and one-hundred (100) year design
storms modeled as 24-hour SCS Type III design storms as compared to existing conditions. Please
refer to the appendix of this report for the hydrography summary reports indicating the same.
Pre-Development and Post Development Peak Runoff Results Summary
for North Oraton Parkway and Freeway Drive East
Design Storm Pre-Development
Conditions
Post-Development
Conditions
Reduction in
Flow
2 Year 0.751 CFS 0.709 CFS 0.042 CFS
10 Year 1.147 CFS 1.105 CFS 0.042 CFS
100 Year 1.910 CFS 1.872 CFS 0.038 CFS
III. Proposed Water System
A 2.5” domestic water service line is proposed to connect to the existing main located long North
Oraton Parkway.
a) DOMESTIC WATER DEMAND CALCULATIONS
In accordance with N.J.A.C. 7:10-12.6(2) 2 – Table 1, the NJDEP standard for the daily
domestic water demand for multiple family dwellings (apartments) is 75 gallons per person.
Estimated domestic water average daily demand can be calculated as follows:
KSH N. Oraton Development, LLC - 3 - December 2020
DEC# 3421-99-001 Last Revised February 2021
• Multiple family dwelling (28 one-bedroom & 12 two-bedroom units)
o 52 Persons * 75 GPD = 3,900 GPD
• Total Proposed Water Average Daily Demand = 3,900 GPD
IV. Proposed Sanitary Sewer System
A 6” SDR-35 sanitary sewer service lateral is proposed to connect to the existing sanitary sewer main
located within Freeway Drive East via doghouse manhole connection
a) PROPOSED SANITARY SEWER DEMANDS
In accordance with N.J.A.C. 7:14A-23.3(a), the NJDEP standard for the daily sanitary
sewerage flow for the one (1) bedroom units are 150 GPD and two (2) bedroom units are 225
GPD.
Estimated sanitary sewer average daily demand can be calculated as follows:
• One (1) bedroom unit:
o 28 Units* 150 GPD/Unit = 4,200 GPD
• Two (2) bedroom unit:
o 12 Units *225 GPD/Unit = 2,700 GPD
• Total Proposed Sanitary Sewer Demand = 6,900 GPD
b) PROPOSED SANITARY SEWER DESIGN
Per NJDEP regulations, the criteria for establishing the size of sanitary sewer gravity pipes is
to convey two times the average flow with the pipe flowing half full. Utilizing Manning’s
equation with a roughness coefficient of 0.010 for a PVC pipe, the following is the minimum
capacity of the proposed gravity sewer lateral.
Pipe Size Minimum Slope Roughness (n) Capacity at ½ Full 2 X ADF
6” 2.08% 0.010 334,262 GPD 13,800 GPD
The proposed sanitary sewer design can efficiently convey two times the proposed average
daily flow at minimum required pipe slope while flowing half full while utilizing
approximately 4.1% of the line’s total capacity.
KSH N. Oraton Development, LLC - 4 - December 2020
DEC# 3421-99-001 Last Revised February 2021
V. Conclusion
The proposed project has been designed to ensure safe and efficient control of the stormwater runoff
in a manner that will not adversely impact the existing drainage patterns and systems, adjacent
roadways, or adjacent parcels. Furthermore, the project decreases the impervious coverage on-site and
thereby does not increase the peak stormwater runoff rates from the parcel. In addition, this report has
been prepared to further expand on the water and sanitary sewer designs for the proposed development
as shown within the accompanying site plan drawings. The water and sanitary sewer demand
generated from this development will not exceed the approved demands and allocated flows based on
the actual usages. We anticipate that the proposed development will not significantly impact the
existing drainage & utility infrastructure located within North Oraton Parkway, Freeway Drive East,
and Route 280.
Soil Map—Essex County, New Jersey
Natural ResourcesConservation Service
Web Soil SurveyNational Cooperative Soil Survey
5/13/2020Page 1 of 3
4512
190
4512
199
4512
208
4512
217
4512
226
4512
235
4512
244
4512
253
4512
262
4512
190
4512
199
4512
208
4512
217
4512
226
4512
235
4512
244
4512
253
4512
262
566797 566806 566815 566824 566833 566842 566851
566806 566815 566824 566833 566842 566851
40° 45' 31'' N74
° 1
2' 3
1'' W
40° 45' 31'' N
74° 1
2' 2
8'' W
40° 45' 28'' N
74° 1
2' 3
1'' W
40° 45' 28'' N
74° 1
2' 2
8'' W
N
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 18N WGS840 15 30 60 90
Feet0 5 10 20 30
MetersMap Scale: 1:356 if printed on A portrait (8.5" x 11") sheet.
Soil Map may not be valid at this scale.
MAP LEGEND MAP INFORMATION
Area of Interest (AOI)Area of Interest (AOI)
SoilsSoil Map Unit Polygons
Soil Map Unit Lines
Soil Map Unit Points
Special Point FeaturesBlowout
Borrow Pit
Clay Spot
Closed Depression
Gravel Pit
Gravelly Spot
Landfill
Lava Flow
Marsh or swamp
Mine or Quarry
Miscellaneous Water
Perennial Water
Rock Outcrop
Saline Spot
Sandy Spot
Severely Eroded Spot
Sinkhole
Slide or Slip
Sodic Spot
Spoil Area
Stony Spot
Very Stony Spot
Wet Spot
Other
Special Line Features
Water FeaturesStreams and Canals
TransportationRails
Interstate Highways
US Routes
Major Roads
Local Roads
BackgroundAerial Photography
The soil surveys that comprise your AOI were mapped at 1:12,000.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale.
Please rely on the bar scale on each map sheet for map measurements.
Source of Map: Natural Resources Conservation ServiceWeb Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required.
This product is generated from the USDA-NRCS certified data as of the version date(s) listed below.
Soil Survey Area: Essex County, New JerseySurvey Area Data: Version 15, Sep 16, 2019
Soil map units are labeled (as space allows) for map scales 1:50,000 or larger.
Date(s) aerial images were photographed: Aug 25, 2014—Sep 27, 2014
The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident.
Soil Map—Essex County, New Jersey
Natural ResourcesConservation Service
Web Soil SurveyNational Cooperative Soil Survey
5/13/2020Page 2 of 3
Map Unit Legend
Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI
USBOOB Urban land, Boonton substratum - Boonton complex, red sandstone lowland, 0 to 8 percent slopes
0.3 100.0%
Totals for Area of Interest 0.3 100.0%
Soil Map—Essex County, New Jersey
Natural ResourcesConservation Service
Web Soil SurveyNational Cooperative Soil Survey
5/13/2020Page 3 of 3
Project: Proposed Multi-Family Apartment Building Computed By: RTO
Job #: 3421-99-001 Checked By: LMS
Location: East Orange, NJ Date:
Drainage Area Impervious
Area (acre)
Impervious
Area (sf)
Curve
Number
(CN) Used
Avg. Perv.
Curve
Number
Total
Pervious
Area
(acres)
Total Area
(acres)
TC (Min.)
NORTH ORATON PARKWAY 0.31 13,296 98 N/A N/A 0.31 10
Total 0.31 13296.00 0.00 0.31
USBOOB HSG D Soil Urban
DescriptionImpervious Surface 98
Gravel 91Open Space (lawn) (good) 80
Woods (good) 77
12/1/2020
Runoff Curve Number (CN) (HSG
D)
Per County Soil Survey -
Project: Proposed Multi-Family Apartment Building Computed By: RTO
Job #: 3421-99-001 Checked By: JEH
Location: East Orange, NJ Date:
Drainage Area Impervious
Area (acre)
Impervious
Area (sf)
Curve
Number
(CN) Used
HSG D -
Open
Space Area
(acre)
HSG D -
Open
Space Area
(sf)
Curve
Number
(CN) Used
Avg. Perv.
Curve
Number
Total
Pervious
Area
(acres)
Total Area
(acres)
TC (Min.)
NORTH ORATON PARKWAY 0.27 11,559 98 0.04 1,737 80 80 0.04 0.31 10
Total 0.27 11559.00 0.04 1737.00 0.04 0.31
USBOOB HSG D Soil Urban
DescriptionImpervious Surface 98
Gravel 91Open Space (lawn) (good) 80
2/17/2021
Runoff Curve Number (CN) (HSG
D)
Per County Soil Survey -
NOTES:Project: Proposed Mult-Family Apartment Building Computed By: ACC 1) Design method used is Rational Method, unless otherwise noted.Job #: 3421-99-001 Checked By: RTO 2) Refer to Weighted Runoff Coefficient table
Location: East Orange Date: 11/30/2020 for calculation of incremental areas and C valuesDesign Storm: 25 YR
SUBCATCHMENT AREA
CUMULATIVE I PIPING INPUT PIPING DATA
FROM TO Area (Acres) "C" A x C Ac A x C (acres)Tc to Inlet (min)
Tc in Pipe
(min.)
Final Tc (min)
(In/Hr)Q to Inlet
(CFS)
Q cum. for Pipe (CFS)
Dia. (In)
Length (Ft)
Man. "n"
Slope (ft/ft)
Pipe Capacity
(cfs)
Pipe Velocity
(fps)
Trench Drain 1 Inlet 16 0.01 0.95 0.01 0.01 10 0.19 10 6.80 0.07 0.07 4 32 0.01 0.01 0.25 2.87Trench Drain 2 Inlet 16 0.01 0.95 0.01 0.01 10 0.05 10 6.80 0.07 0.07 4 9 0.01 0.01 0.25 2.87Trench Drain 3 Inlet 16 0.01 0.95 0.01 0.01 10 0.21 10 6.80 0.07 0.07 4 36 0.01 0.01 0.25 2.87Roof Leader 1 Inlet 16 0.08 0.95 0.08 0.08 10 0.1 10 6.80 0.54 0.54 6 23 0.01 0.01 0.73 3.72Roof Leader 2 Inlet 16 0.08 0.95 0.08 0.08 10 0.1 10 6.80 0.54 0.54 6 23 0.01 0.01 0.73 3.72Roof Leader 3 Inlet 16 0.08 0.95 0.08 0.08 10 0.22 10 6.80 0.54 0.54 6 50 0.01 0.01 0.73 3.72
Inlet 16 Inlet 17 0.07 0.95 0.07 0.34 10 0.26 10.22 6.80 0.48 2.31 15 58 0.013 0.005 4.57 3.73Trench Drain 4 Inlet 17 0.01 0.95 0.01 0.01 10 0.29 10 6.80 0.07 0.07 4 50 0.01 0.01 0.25 2.87Trench Drain 5 Inlet 17 0.01 0.95 0.01 0.01 10 0.18 10 6.80 0.07 0.07 4 31 0.01 0.01 0.25 2.87
Inlet 17 Inlet 18 0.07 0.95 0.07 0.43 10 0.21 10.48 6.80 0.48 2.92 15 46 0.013 0.005 4.57 3.73Inlet 18 Manhole 10 0.01 0.95 0.01 0.44 10 0.16 10.69 6.68 0.07 2.94 15 36 0.013 0.005 4.57 3.73
PIPE SECTION INCREMENTALTIME OF
CONCENTRATIONPEAK RUNOFF
ã
1904 Main StreetLake Como, NJ 07719
T: 732.974.0198F: 732.974.3521
www.dynamicec.com
LAND DEVELOPMENT CONSULTING ● PERMITTING ● GEOTECHNICAL ● ENVIRONMENTAL ● SURVEY ● PLANNING & ZONINGOffices conveniently located in:
Lake Como, New Jersey T: 732.974.0198 | Chester, New Jersey T: 908.879.9229 | Newark, New Jersey T: 973.755.7200 | Toms River, New Jersey T: 732.974.0198Allen, Texas T: 972.534.2100 | Austin, Texas T:512.646.2646 | Houston, Texas T: 281.789.6400
Newtown, Pennsylvania T: 267.685.0276 | Delray Beach, Florida T: 561.921.8570
JAMES E. HENRYJOSHUA M. SEWALD
UP
ã
1904 Main StreetLake Como, NJ 07719
T: 732.974.0198F: 732.974.3521
www.dynamicec.com
LAND DEVELOPMENT CONSULTING ● PERMITTING ● GEOTECHNICAL ● ENVIRONMENTAL ● SURVEY ● PLANNING & ZONINGOffices conveniently located in:
Lake Como, New Jersey T: 732.974.0198 | Chester, New Jersey T: 908.879.9229 | Newark, New Jersey T: 973.755.7200 | Toms River, New Jersey T: 732.974.0198Allen, Texas T: 972.534.2100 | Austin, Texas T:512.646.2646 | Houston, Texas T: 281.789.6400
Newtown, Pennsylvania T: 267.685.0276 | Delray Beach, Florida T: 561.921.8570
JAMES E. HENRYJOSHUA M. SEWALD
UP
ã
1904 Main StreetLake Como, NJ 07719
T: 732.974.0198F: 732.974.3521
www.dynamicec.com
LAND DEVELOPMENT CONSULTING ● PERMITTING ● GEOTECHNICAL ● ENVIRONMENTAL ● SURVEY ● PLANNING & ZONINGOffices conveniently located in:
Lake Como, New Jersey T: 732.974.0198 | Chester, New Jersey T: 908.879.9229 | Newark, New Jersey T: 973.755.7200 | Toms River, New Jersey T: 732.974.0198Allen, Texas T: 972.534.2100 | Austin, Texas T:512.646.2646 | Houston, Texas T: 281.789.6400
Newtown, Pennsylvania T: 267.685.0276 | Delray Beach, Florida T: 561.921.8570
JAMES E. HENRYJOSHUA M. SEWALD
Project: Parkway Commons Computed By: AC
Job #: 3421-99-001 Checked By: RTO
Location: City of East Orange, Essex County, NJ Date: 2/15/2021
PIPE DESCRIPTION SLOPE SIZE MANNING'S VELOCITY CAPACITY CAPACITY CAPACITY
(%) (IN) COEFFICIENT (FT/S) (CFS) (GPD) (MGD)
(n)
Prop. 6" Lateral 2.080% 6 0.010 5.27 0.52 334,262 0.33
Variables Defined Typical Values for Manning's Coefficient (n)
Q=Capacity of Pipe (CFS) n(RCP)= 0.013
V=Velocity in Pipe Section (FT/S) n(HDPE-Smooth Interior)= 0.012 *Varies with Manufacturer
R=Hydraulic Radius of Pipe Section n(DIP)= 0.013
S=Slope of Pipe Section (FT/FT) n(PVC)= 0.010
D=Diameter of Pipe (FT) n(CMP)= 0.024
d=Depth of Flow in Pipe (FT)
n=Manning's Coefficient
Wp=Wetted Perimeter (FT)
Equations used:
Q=VA
V=(1.49/n)*R^(2/3)*S^(1/2)
Q=(1.49/n)*R^(2/3)*S^(1/2)*A
Utilizing Appendix 16.A from the Civil Engineering Reference Manual-Seventh Edition, by Micheal Lindeburg, Copyright 1999
The following equations were utilized to calculate the Hydraulic Radius and Area of a Circular Pipe Section flowing 1/2 full
A=(π*D^2/4)*0.5=0.3927*D^2
R=A/Wp=0.3927*D^2/((2*π*D/2)*0.5)=0.25*D
Therefore:
Q=(1.49/n)*(0.25*D)^(2/3)*S^(1/2)*(0.3927*D^2)
V=(1.49/n)*(0.25*D)^(2/3)*S^(1/2)
Unit Conversion Equations
1 Cubic Foot=7.4805 Gallons
1 Day = 86,400 Seconds
Therefore:
Cubic Foot 86,400 Seconds 7.4805 Gallons Gallon
Second 1 Day 1 Cubic Foot Day
Gallon 1 Million Gallons Million Gallons
Day 1,000,000 Gallons Day
=X X
X =