Air Insulated switchgear 311216.cdr A4
-
Upload
khangminh22 -
Category
Documents
-
view
6 -
download
0
Transcript of Air Insulated switchgear 311216.cdr A4
MV Switchgear Range from the leaders in LV Switchgear
Diverse demands. Numerous applications. SINGLE SOLUTIONS.
Switchgear Factory, Ahmednagar
Switchgear Factory, Navi Mumbai
Switchgear Factory, Vadodara
L&T Switchgear, a part of the
Electrical and Automation business,
is India’s largest manufacturer of
low voltage switchgear, with the
scale, sophistication and range to
meet global benchmarks.
With over, Six decades of experience
in this field, the company today
enjoys a leadership position in the
Indian electrical market with growing
presence in international markets.
Larsen and Toubro entered into
medium voltage field by acquiring
Malaysian company TAMCO in 2008.
TAMCO has over four decades of
experience in MV switchgear and
supplied to large number of
customers worldwide.
Our ranges of MV products are
manufactured at various factories
across the world. In India these are
manufactured at L&T’s state of
the art facility at Ahmednagar.
Our MV products have worldwide
acceptance in sectors like Metals,
Power, Oil & Gas, Petrochemicals,
Infrastructure, Buildings, etc.
1 ABOUT US
Ahmednagar MV Manufacturing Facility
Air Insulated Switchgear (AIS) is used for control and protection of electrical power
distribution system. In our AIS, Vacuum Circuit Breaker (VCB) is used as the switching
device with air as the insulating medium in a metal clad enclosure. The protection and
control is offered by numerical relays.
The VCB is type tested as per IEC 62271-100 and the metal clad enclosure is type
tested as per IEC 62271-200, at reputed international laboratories viz. CPRI, ERDA,
CESI, KEMA, ASTA to assure highest quality standards.
The AIS panel is available for the system voltage of 3.3kV, 6.6kV, 11kV, 22kV, & 33kV
and for current ratings upto 3150A with natural cooling. The short circuit ratings are
available upto 50kA for 3 sec for 11kV & 31.5kA for 3 sec for 33kV. To prove its
suitability for use in severe climatic conditions, the switchgear has been subjected to
climatic aging tests according to IEC 60932, and proven to Design Class 2 (the highest
class). The switchgear has been designed and tested as per IEC 62271-200 to ensure
the safety of the operator in the event of an internal-arc fault. Arc vents are provided in
the busbar, cable and VCB compartments.
The switchgear has also been successfully tested to withstand seismic forces of 5-7 on
the Richter scale, in accordance with IEC 60068-3-3.
AIR INSULATED SWITCHGEAR (AIS) 2
* 36kV VCB will be given for 24kV requirements.
11kV, 800A, 40kA VCB 33kV, 800A, 31.5kA VCB
OFFERINGS3
Fault Level (kA)
Current Rating(A)
Rated Voltage
Type ofPanel
630A 800A 1250A
26.3
800A2000A 1250A 2000A
40/50
3150A
upto12kV
Full panel
Sub-cubicle
Half-panel
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
Fault Level (kA)
Current Rating(A)
Rated Voltage
Type ofPanel
800A 1250A
31.5
2000A
24kV*
Full panel
Half-panel
�
�
�
�
�
�
Fault Level (kA)
Current Rating(A)
Rated Voltage
Type ofPanel
800A 1250A
31.5
2000A
36kV
Full panel
Half-panel
�
�
�
�
�
�
PANEL OPTIONS
• Full Panel: Complete panel having all components as per specification / BOM
• Subcubicle: VCB compartment, i.e. VCB in an enclosure with door and
safety interlocks
• Half Panel: Consist of VCB and fabrication of VCB compartment, Busbar
compartment, LV compartment and Cable compartment. LV components, Control
wiring, Busbar, Busbar links & supports, CTs and PTs are not included
GENERAL
• Complies with IEC 62271-100, 62271-102 and 62271-200
• Metal clad, fully compartmentalized panel
• Horizontal isolation, horizontal draw-out & floor rolling trolley type VCB
• Panel readily extensible on both sides
• Panel is designed to meet temperature rise limits as per standards
• Fully type tested at renowned STL laboratories
• Partition class is PM
• Mechanical endurance class is M2
• Electrical endurance class is E2
• Loss of service continuity category is LSC2B
• Indoor type panel with ingress protection rating IP4X (Higher IP on request)
SAFETY
• True close door operation as per IEC standard
• Rack in / Rack out, breaker closing / tripping are behind closed door
• Automatic independent safety shutters to prevent accidental contact with live parts
• Pad lockable door to ensure operator safety
USER FRIENDLY
• Compact, light weight & hence easy to maneuver
• Generous space for cable termination
• Safety Shutters with individual padlocking facility are available.
Both the shutters can be independently kept in open or close
position during maintenance
• Draw out and fixed type PT available
UNIQUE
• Current rating upto 3150A with natural cooling
• Internal arc classification AFLR upto 40kA for 1 second
and 50kA for 0.5 second
• Compact and safe
• Single latch door closing & optional rear door interlock
4
VCB Compartment Busbar Compartment
* 12NO + 12NC auxiliary contacts can be given on request for 26.3kA, 40kA & 50kA VCBs.** For 33 kV VCB Closing & tripping coil voltage available for 110V & 220V DC.
IEC 62271-100, IEC 62271-102, IEC 62271-200
12kV 24kV 36kV
630, 8001250, 2000
800, 12502000, 3150
800, 12502000, 3150
800, 12502000
800, 12502000
50 Hz
O-0.3 sec-CO-3 min-CO
<3 Cycles
>10,000 operations
IP4X (Higher IP on request)
24V, 30V, 110V, 220V DC **
110V, 220V DC/ 110V, 230V AC
6NO + 6NC *
26.3kA 40kA 50kA 31.5kA 31.5kA
3 sec
65.75kA 100kA 125kA 79kA 79kA
75kVp 125kVp 170kVp
28kV (rms) 50kV (rms) 70kV (rms)
Standards
Voltage
Frequency
Short time current rating
Duration of short circuit withstand
Making Capacity
Impulse withstand voltage
One minute power frequency withstand
Suitable for operating sequence
Break time
Mechanical life
Degree of protection
Closing and tripping coil voltage
Spring charging motor voltage
Auxiliary contacts*
Normal current (A)
TECHNICAL SPECIFICATION5
DIMENSIONAL DRAWING 6
12kV, 800A, 26.3kA Full Panel with PT
VCB
METERING
COMPARTMENT
600
FDR.
800A
24
95
1570
21
70
WOUNDCT
PT
METERING
COMPARTMENT
BUSBARCOMPARTMENT
BREAKERCOMPARTMENT
CABLE COMPARTMENT
R
Y
B
BREAKER COMPARTMENT
12kV, 800A, 26.3kA Full Panel without PT
600
METERING
COMPARTMENT
21
95
21
70
WOUND
CT
FDR.
800 AVCB
METERING
COMPARTMENT
1570
BUSBARCOMPARTMENT
BREAKERCOMPARTMENT
CABLE COMPARTMENT
R
Y
B
BREAKER COMPARTMENT
7 DIMENSIONAL DRAWING
12kV, 800A, 26.3kA Bus Sectionalizer Panel
12kV, 800A, 26.3kA ICOG Full Panel with PT
600
METERINGCOMPARTMENT
FDR
800AVCB
24
95
1970
21
70
WOUND CT
BUSBAR COMPARTMENT
BREAKERCOMPARTMENT
CABLE COMPARTMENT
METERING
COMPARTMENT
BREAKER COMPARTMENT
600
METERINGCOMPARTMENT
FDR
800AVCB
21
95
1970
WOUNDCT
BREAKERCOMPARTMENT
BUSBARCOMPARTMENT
CABLE COMPARTMENT
R
Y
B
BREAKER COMPARTMENT
METERING
COMPARTMENT
21
70
DIMENSIONAL DRAWING 8
12kV, 800A, 26.3kA Half Panel without CT, PT
12kV, 630A, 26.3kA Subcubicle
600
METERINGCOMPARTMENT
FDR
800AVCB
21
95
1570
21
70
BREAKERCOMPARTMENT
BUSBARCOMPARTMENT
R
Y
B
CABLE COMPARTMENT
METERING
COMPARTMENT
BREAKER COMPARTMENT
600
BREAKERCOMPARTMENT
16
19
12
26
METERINGCOMPARTMENT
SHUTTERBUSBAR
COMPARTMENT
CABLINGCOMPARTMENT
1012
DIMENSIONAL DRAWING9
12kV, 800A, 40kA Full Panel with PT
12kV, 800A, 40kA Full Panel without PT
6002
49
5
BREAKER COMPARTMENT
METERINGCOMPARTMENT
1570
21
70
METERINGCOMPARTMENT
BREAKERCOMPARTMENT
BUSBARCOMPARTMENT
R Y
B
WINDOWCT
LINEVT
FDR
800A VCB
CABLE COMPARTMENT
600
24
95
BREAKER COMPARTMENT
METERINGCOMPARTMENT
FDR
1570
21
70
METERINGCOMPARTMENT
BREAKER COMPARTMENT
BUSBARCOMPARTMENT
R Y
B
WINDOWCT
800A VCB
CABLE COMPARTMENT
DIMENSIONAL DRAWING 10
12kV, 800A, 40kA ICOG Full Panel with PT
12kV, 800A, 40kA ICOG Half Panel without CT, PT
600
METERING
COMPARTMENT
800AVCB
24
95
1970
21
70
BREAKER COMPARTMENT
BUSBAR COMPARTMENT
BREAKERCOMPARTMENT
CABLE COMPARTMENT
METERING
COMPARTMENT
600
METERINGCOMPARTMENT
FDR
800AVCB
24
95
1970
21
70
WOUND CT
BREAKER COMPARTMENT
BREAKERCOMPARTMENT
CABLE COMPARTMENT
METERING
COMPARTMENT
BUSBAR COMPARTMENT
DIMENSIONAL DRAWING11
33kV, 800A, 31.5kA Standard Half Panel without PT, CT
800A VCB
METERINGCOMPARTMENT
1000
25
00
2650
30
40
BREAKER COMPARTMENT
METERING
COMPARTMENT
BREAKERCOMPARTMENT
BUSBARCOMPARTMENT
RY
B
CABLE COMPARTMENT
33kV, 800A, 31.5kA Standard Full Panel with PT
1000
METERINGCOMPARTMENT
FDR
800A VCB
25
00
2650
30
40
BUSBARCOMPARTMENT
PT
WOUNDCT
METERING
COMPARTMENT
BREAKERCOMPARTMENT
BUSBARCOMPARTMENT
BREAKER COMPARTMENT
CABLE COMPARTMENT
RY
B
DIMENSIONAL DRAWING 12
33kV, 800A, 31.5kA ICOG Half Panel without PT, CT
33kV, 800A, 31.5kA ICOG Full Panel with PT
1000
GA
SD
UC
TO
UT
LE
T
METERINGCOMPARTMENT
FDR
800A VCB
25
00
3250
30
40
INC
OM
ING
P
OW
ER
C
AB
LE
S
OU
TG
OIN
GP
OW
ER
C
AB
LE
S
BUSBAR COMPARTMENT
BREAKERCOMPARTMENT
CABLE COMPARTMENT
METERING
COMPARTMENT
BREAKER COMPARTMENT
* All Dimensions are in mm
800A VCB
METERINGCOMPARTMENT
1000
GA
SD
UC
TO
UT
LE
T
25
00
3250
INC
OM
ING
P
OW
ER
C
AB
LE
S
OU
TG
OIN
GP
OW
ER
C
AB
LE
SBREAKERCOMPARTMENT
BUSBAR COMPARTMENT
CABLE COMPARTMENT
BREAKERCOMPARTMENT
30
40
OPTIONAL ACCESSORIES
•
• Annunciator & Hooter
• Power pack with inbuilt battery backup
• Earthing Truck
Bus earthing truck & Line/Cable earthing truck are available with safety interlocks
• Earthing Switch
Integral earthing switch can be provided for earthing cable/line. Bus earthing switch for busbar side
will also provided. Earth switch are provided with full making capacity
Surge arresters
Earthing Switch Earthing Truck
Current Rating (A)
Rated voltage Dimensions
12kV(26.3kA/40kA)
24kV & 36kV*(31.5kA)
Width (mm)
Depth (mm)
Height (mm)
Width (mm)
Depth (mm)
Height (mm)
600
1570
2195
1000
2650
2500
600
1570
2195
1000
2650
2500
800
1970
2195
1000
2650
2500
1000
1970
2195
800 1250 2000 3150
•
• Height will change depending on components of LV compartment.
* 36kV VCB will be provided for 24kV VCB requirement.
Depth will vary with the no. & size of cable & current transformers.
DIMENSIONS13
ORDERING PARAMETERS
2. BREAKER RACK IN/RACK OUT INTERLOCKS
• VCB cannot be racked in/out when it is in closed position and is possible only when it is in open position
• VCB can be closed only when it is either in test or service position
• VCB cannot be closed in the intermediate position
3. EARTHING SWITCH INTERLOCKS
4. OTHER INTERLOCKS
• Earthing switch cannot be closed when VCB is in service position
• VCB cannot be racked in from isolated or test position to service position when earthing switch is closed
• Earthing switch can be closed only when VCB is in isolated or test position
• VCB cannot be closed electrically unless spring is fully charged
• VCB compartment door cannot be opened when VCB is in service & intermediate position & can be opened
only when the VCB is in test / isolated position
• Safety shutter opens automatically when the VCB is racked in the service position
• Safety shutter closes automatically when the VCB is racked out from the service position
• Rear door interlock can be provided on request. Rear door cannot be opened when the VCB is in
service & intermediate position and can be opened only when the VCB is in test/isolated position
or taken out from panel.
* For subcubicle control supply voltage should be mention during ordering.
SAFETY INTERLOCKS 14
1. SECONDARY DISCONNECTING SWITCH (SDS) INTERLOCKS
• VCB cannot be racked in unless the SDS plug is inserted
• SDS plug cannot be removed when VCB is in service or intermediate position
• SDS plug can be removed only when the VCB is in test or isolated position
Application
Voltage
Current Rating (A)
Short Circuit BreakingCapacity
Panel Options
Panel Version
Frequency
Busbar Type
CT Details
PT Details
Meters
Control Supply Voltage
12kV 24kV 36kV
630, 800,1250, 2000
26.3kA 40kA / 50kA
800, 1250,2000, 3150
31.5kA 31.5kA
800, 1250, 2000 800, 1250, 2000
Full Panel/Half Panel/ICOG/Subcubicle*
With PT/Without PT
50 Hz
Copper/Aluminium
Ratio/VA rating/Accuracy Class
Ratio/ /Accuracy ClassVA rating
A/V/MFM/TVM/Other
24/110/220V DC or 110/230V AC
Feeder/Transformer/Motor/Capacitor/Generator Protection/Other
• VCU available upto current rating 400A & Voltage rating 7.2kV
(12kV VCU will be offered on request)
• Fused short circuit protection up to 50kA
• Available in latched & non latched configurations
• Encapsulated current carrying parts for higher safety
• Truck mounted design similar to draw out VCB
• Suitable for motor starters with numerous switching operations
• Two VCUs can be accommodated in single panel for optimum
space utilisation
• VCU panels can be coupled with VCB panels owing to similar
dimensions
15 VACUUM CONTACTOR UNIT
# 2 Tier Panel width & depth starts from 800 mm & 1970 mm respectively*12kV VCU will be offered on request.
Standards
Type Designation
Voltage
Power Frequency Withstand Voltage
Impulse Withstand Voltage
Frequency
Rated Current
Short Time Withstand Current
Short Time Withstand Current (with Fuse)
Width#
Depth#
Height
Partition Class
Loss of Service continuity
Degree of Protection
Damage Classification
Internal Arc Classification
IEC Standard
VCU Type
Type Designation
Opening time
Mechanical Endurance
Electrical Endurance
Rated Duties (40% on Load Factor)
Closing/Tripping Coil
Auxiliary Contacts
IEC 62271-200
VH1H
up to 7.2kV*
20 kVrms
60 kVp
50 / 60 Hz
200 - 400 A
up to 8kA
25 / 40 / 50kA
600 MM
1570 / 1970 MM
2195 / 2495 MM
PM
LSC-2B
IP4X (Higher IP on request)
Type C
A (F, L, R), 40kA, upto 1s
IEC 62271-106
<35 ms
upto 0.3 Million (AC-3)
Class 300
110 / 220 V DC
3NO + 3NC
Panel Details
Voltage Ratings
Current Ratings
Dimensions
Construction
VCU
Non Latched Latched
VCU7N200 VCU7N400 VCU7L200 VCU7L400
upto 3 Million upto 0.3 Million
7.2kV AIS with VCU
16TECHNICAL SPECIFICATIONS
Please contact any of the training centres for participation and detailed training programme schedule.
So gain the advantage and go the extra mile with:�
�
�
�
The typical training programmes cover:
�
�
�
�
�
22 courses on contemporary topicsCourses applicable to all switchgear brandsTraining Centers in Pune, Lucknow, Coonoor, Vadodara, Delhi & KolkataBlend of theory and practical experience
Low Voltage & Medium Voltage Switchgear
Switchboard Electrical Design
AC Drives & Building Management Solutions
Protective Relays & Earthing
Power Quality Solutions
Pune
Larsen & Toubro LimitedSwitchgear Training Centre, T-156/157, MIDCBhosari, Pune - 411 026Tel: 020 2712 0037 / 2712 0653 Fax: 020 2712 2933 E-mail: [email protected]
Lucknow
Larsen & Toubro LimitedSwitchgear Training Centre, C - 6 & 7, UPSIDCP. O. Sarojininagar, Lucknow - 226 008Tel: 0522 247 6015 / 97944 54455 Fax: 0522 247 6015 E-mail: [email protected]
Coonoor
Larsen & Toubro LimitedSwitchgear Training Centre, Ooty-Coonoor Main RoadYellanahalli P.O., The Nilgiris - 643 243Tel. : 0423 251 7107Fax : 0423 251 7158E-mail: [email protected]
Vadodara
Larsen & Toubro LimitedSwitchgear Training CentreBehind L&T Knowledge City, Near Village Ankhol, Vadodara - 390019Tel: 0265 2457805E-mail: [email protected]
Delhi
Larsen & Toubro LtdSwitchgear Training Centre32, Shivaji Marg,Near Motinagar Metro Station,New Delhi - 110015 Tel: 011 41419515 / 41419695 / 41419500Fax: 011 41419600E-mail: [email protected]
Kolkata
Larsen & Toubro LimitedSwitchgear Training Centre4th Floor, 3B, Shakespeare Sarani, Kolkata - 700071Tel: 033 42005975 / 42005978E-mail: [email protected]
Aimed at maximizing productivity, conserving energy, minimizing costs and enhancing safety, our Electrical
& Automation training programmes have benefitted over 1.35 Lakh professionals in the last 28 years. These
training programmes are highly beneficial as they provide right exposure and impart knowledge on
selection, installation, maintenance and testing of Electrical & Automation Products.
Khairasol, Degaul AvenueDurgapur 713 212Tel: 0343-2540448 / 2540449 / 2540443Fax: 0343-2540442e-mail: [email protected]
5, Milanpur Road, Bamuni MaidanGuwahati 781 021Tel: +91 8876554410 / 8876554417Fax: 361-2551308e-mail: [email protected]
II Floor, Vasantha Chambers5-10-173, Fateh Maidan RoadHyderabad 500 004Tel: 040-67015052Fax: 040-23296468e-mail: [email protected]
Monarch Building, 1st FloorD-236 & 237, Amrapali MargVaishali NagarJaipur 302 021Tel: 0141-4385914 to 18Fax: 0141-4385925e-mail: [email protected]
Akashdeep Plaza, 2nd FloorP. O. GolmuriJamshedpur 831 003JharkhandTel: 0657-2312205 / 38Fax: 0657-2341250e-mail: [email protected]
Skybright Bldg; M. G. RoadRavipuram Junction, ErnakulamKochi 682 016Tel: 0484-4409420 / 4 / 5 / 7Fax: 0484-4409426e-mail: [email protected]
3-B, Shakespeare SaraniKolkata 700 071Tel: 033-42005982Fax: 033-22821025 / 7587e-mail: [email protected]
A28, Indira Nagar, Faizabad Road Lucknow 226 016Tel: 0522-4929905 / 04Fax: 0522-2311671e-mail: [email protected]
No: 73, Karpaga Nagar, 8th StreetK. PudurMadurai 625 007Tel: 0452-2567405 / 2561068 / 2561657Fax: 0452-2567552e-mail: [email protected]
Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here.
Electrical Standard Products (ESP) Offices:
HEAD OFFICEL&T Business Park,Tower 'B' / 3rd FloorSaki Vihar Road, PowaiMumbai 400 072Tel: 022-67053229 Fax: 022-67051112e-mail: [email protected]
BRANCH OFFICES501, Sakar Complex I Opp. Gandhigram Rly. Station Ashram RoadAhmedabad 380 009Tel: 079-66304006-11Fax: 079-66304025e-mail: [email protected]
38, Cubbon Road, P. O. Box 5098Bengaluru 560 001Tel: 080-25020100 / 25020324Fax: 080-25580525e-mail: [email protected]
131/1, Zone IIMaharana Pratap NagarBhopal 462 011Tel: 0755-3080511 / 05 / 08 / 13 / 17 / 19 Fax: 0755-3080502e-mail: [email protected]
Plot No. 559, Annapurna ComplexLewis RoadBhubaneswar 751 014Tel: 0674-6451342 / 2436690 / 2436696Fax: 0674-2537309e-mail: [email protected]
Aspire Towers, 4th FloorPlot No. 55, Phase-IIndustrial & Business ParkChandigarh-160 002Tel: 0172-4646840 / 41 / 42 / 46 / 53Fax: 0172-4646802Email: [email protected]
L&T Construction CampusTC-1 Building, II FloorMount-Poonamallee RoadManapakkamChennai 600 089Tel: 044-2270 6800Fax: 044-22706940e-mail: [email protected]
67, Appuswamy RoadPost Bag 7156 Opp. Nirmala CollegeCoimbatore 641 045Tel: 0422-2588120 / 1 / 5Fax: 0422-2588148e-mail: [email protected]
L&T Business Park,Tower 'B' / 5th FloorSaki Vihar Road, PowaiMumbai 400 072Tel: 022-67052874 / 2737 / 1156Fax: 022-67051112e-mail: [email protected]
12, Shivaji NagarNorth Ambajhari RoadNagpur 440 010Tel: 0712-2260012 / 6606421Fax: 2260030 / 6606434e-mail: [email protected]
32, Shivaji Marg P. O. Box 6223New Delhi 110 015Tel: 011-41419514 / 5 / 6Fax: 011-41419600e-mail: [email protected]
L&T House P. O. Box 119 191/1, Dhole Patil RoadPune 411 001Tel: 020-66033395 / 66033279Fax: 020-26164048 / 26164910e-mail: [email protected]
Crystal Tower, 4th Floor, G. E. RoadTelibandhaRaipur - 492 006Tel: 0771-4283214e-mail: [email protected]
3rd Floor Vishwakarma ChambersMajura Gate, Ring RoadSurat 395 002Tel: 0261-2473726Fax: 0261-2477078e-mail: [email protected]
Radhadaya ComplexOld Padra RoadNear Charotar SocietyVadodara 390 007Tel: 0265-6613610 / 1 / 2Fax: 0265-2336184e-mail: [email protected]
Door No. 49-38-14/3/2, 1st floor,NGGO's Colony, Akkayyapalem,Visakhapatnam - 530 016Tel: 0891-2791126 / 2711125Fax: 0891-2791100Email: [email protected]
Larsen & Toubro Limited, Electrical Standard Products
Powai Campus, Mumbai 400 072
Customer Interaction Center (CIC)
BSNL / MTNL (toll free) : 1800 233 5858 Reliance (toll free) : 1800 200 5858
Tel : 022 6774 5858, Fax : 022 6774 5859
E-mail : [email protected] / Website www.Lntebg.com
Registered Office: L&T House, N. M. Marg, Ballard Estate, Mumbai 400 001, INDIA CIN: L99999MH1946PLC004768
SP 50604 R3