Air Insulated switchgear 311216.cdr A4

20
MV Switchgear Range from the leaders in LV Switchgear Diverse demands. Numerous applications. SINGLE SOLUTIONS.

Transcript of Air Insulated switchgear 311216.cdr A4

MV Switchgear Range from the leaders in LV Switchgear

Diverse demands. Numerous applications. SINGLE SOLUTIONS.

Switchgear Factory, Ahmednagar

Switchgear Factory, Navi Mumbai

Switchgear Factory, Vadodara

L&T Switchgear, a part of the

Electrical and Automation business,

is India’s largest manufacturer of

low voltage switchgear, with the

scale, sophistication and range to

meet global benchmarks.

With over, Six decades of experience

in this field, the company today

enjoys a leadership position in the

Indian electrical market with growing

presence in international markets.

Larsen and Toubro entered into

medium voltage field by acquiring

Malaysian company TAMCO in 2008.

TAMCO has over four decades of

experience in MV switchgear and

supplied to large number of

customers worldwide.

Our ranges of MV products are

manufactured at various factories

across the world. In India these are

manufactured at L&T’s state of

the art facility at Ahmednagar.

Our MV products have worldwide

acceptance in sectors like Metals,

Power, Oil & Gas, Petrochemicals,

Infrastructure, Buildings, etc.

1 ABOUT US

Ahmednagar MV Manufacturing Facility

Air Insulated Switchgear (AIS) is used for control and protection of electrical power

distribution system. In our AIS, Vacuum Circuit Breaker (VCB) is used as the switching

device with air as the insulating medium in a metal clad enclosure. The protection and

control is offered by numerical relays.

The VCB is type tested as per IEC 62271-100 and the metal clad enclosure is type

tested as per IEC 62271-200, at reputed international laboratories viz. CPRI, ERDA,

CESI, KEMA, ASTA to assure highest quality standards.

The AIS panel is available for the system voltage of 3.3kV, 6.6kV, 11kV, 22kV, & 33kV

and for current ratings upto 3150A with natural cooling. The short circuit ratings are

available upto 50kA for 3 sec for 11kV & 31.5kA for 3 sec for 33kV. To prove its

suitability for use in severe climatic conditions, the switchgear has been subjected to

climatic aging tests according to IEC 60932, and proven to Design Class 2 (the highest

class). The switchgear has been designed and tested as per IEC 62271-200 to ensure

the safety of the operator in the event of an internal-arc fault. Arc vents are provided in

the busbar, cable and VCB compartments.

The switchgear has also been successfully tested to withstand seismic forces of 5-7 on

the Richter scale, in accordance with IEC 60068-3-3.

AIR INSULATED SWITCHGEAR (AIS) 2

* 36kV VCB will be given for 24kV requirements.

11kV, 800A, 40kA VCB 33kV, 800A, 31.5kA VCB

OFFERINGS3

Fault Level (kA)

Current Rating(A)

Rated Voltage

Type ofPanel

630A 800A 1250A

26.3

800A2000A 1250A 2000A

40/50

3150A

upto12kV

Full panel

Sub-cubicle

Half-panel

Fault Level (kA)

Current Rating(A)

Rated Voltage

Type ofPanel

800A 1250A

31.5

2000A

24kV*

Full panel

Half-panel

Fault Level (kA)

Current Rating(A)

Rated Voltage

Type ofPanel

800A 1250A

31.5

2000A

36kV

Full panel

Half-panel

PANEL OPTIONS

• Full Panel: Complete panel having all components as per specification / BOM

• Subcubicle: VCB compartment, i.e. VCB in an enclosure with door and

safety interlocks

• Half Panel: Consist of VCB and fabrication of VCB compartment, Busbar

compartment, LV compartment and Cable compartment. LV components, Control

wiring, Busbar, Busbar links & supports, CTs and PTs are not included

GENERAL

• Complies with IEC 62271-100, 62271-102 and 62271-200

• Metal clad, fully compartmentalized panel

• Horizontal isolation, horizontal draw-out & floor rolling trolley type VCB

• Panel readily extensible on both sides

• Panel is designed to meet temperature rise limits as per standards

• Fully type tested at renowned STL laboratories

• Partition class is PM

• Mechanical endurance class is M2

• Electrical endurance class is E2

• Loss of service continuity category is LSC2B

• Indoor type panel with ingress protection rating IP4X (Higher IP on request)

SAFETY

• True close door operation as per IEC standard

• Rack in / Rack out, breaker closing / tripping are behind closed door

• Automatic independent safety shutters to prevent accidental contact with live parts

• Pad lockable door to ensure operator safety

USER FRIENDLY

• Compact, light weight & hence easy to maneuver

• Generous space for cable termination

• Safety Shutters with individual padlocking facility are available.

Both the shutters can be independently kept in open or close

position during maintenance

• Draw out and fixed type PT available

UNIQUE

• Current rating upto 3150A with natural cooling

• Internal arc classification AFLR upto 40kA for 1 second

and 50kA for 0.5 second

• Compact and safe

• Single latch door closing & optional rear door interlock

4

VCB Compartment Busbar Compartment

* 12NO + 12NC auxiliary contacts can be given on request for 26.3kA, 40kA & 50kA VCBs.** For 33 kV VCB Closing & tripping coil voltage available for 110V & 220V DC.

IEC 62271-100, IEC 62271-102, IEC 62271-200

12kV 24kV 36kV

630, 8001250, 2000

800, 12502000, 3150

800, 12502000, 3150

800, 12502000

800, 12502000

50 Hz

O-0.3 sec-CO-3 min-CO

<3 Cycles

>10,000 operations

IP4X (Higher IP on request)

24V, 30V, 110V, 220V DC **

110V, 220V DC/ 110V, 230V AC

6NO + 6NC *

26.3kA 40kA 50kA 31.5kA 31.5kA

3 sec

65.75kA 100kA 125kA 79kA 79kA

75kVp 125kVp 170kVp

28kV (rms) 50kV (rms) 70kV (rms)

Standards

Voltage

Frequency

Short time current rating

Duration of short circuit withstand

Making Capacity

Impulse withstand voltage

One minute power frequency withstand

Suitable for operating sequence

Break time

Mechanical life

Degree of protection

Closing and tripping coil voltage

Spring charging motor voltage

Auxiliary contacts*

Normal current (A)

TECHNICAL SPECIFICATION5

DIMENSIONAL DRAWING 6

12kV, 800A, 26.3kA Full Panel with PT

VCB

METERING

COMPARTMENT

600

FDR.

800A

24

95

1570

21

70

WOUNDCT

PT

METERING

COMPARTMENT

BUSBARCOMPARTMENT

BREAKERCOMPARTMENT

CABLE COMPARTMENT

R

Y

B

BREAKER COMPARTMENT

12kV, 800A, 26.3kA Full Panel without PT

600

METERING

COMPARTMENT

21

95

21

70

WOUND

CT

FDR.

800 AVCB

METERING

COMPARTMENT

1570

BUSBARCOMPARTMENT

BREAKERCOMPARTMENT

CABLE COMPARTMENT

R

Y

B

BREAKER COMPARTMENT

7 DIMENSIONAL DRAWING

12kV, 800A, 26.3kA Bus Sectionalizer Panel

12kV, 800A, 26.3kA ICOG Full Panel with PT

600

METERINGCOMPARTMENT

FDR

800AVCB

24

95

1970

21

70

WOUND CT

BUSBAR COMPARTMENT

BREAKERCOMPARTMENT

CABLE COMPARTMENT

METERING

COMPARTMENT

BREAKER COMPARTMENT

600

METERINGCOMPARTMENT

FDR

800AVCB

21

95

1970

WOUNDCT

BREAKERCOMPARTMENT

BUSBARCOMPARTMENT

CABLE COMPARTMENT

R

Y

B

BREAKER COMPARTMENT

METERING

COMPARTMENT

21

70

DIMENSIONAL DRAWING 8

12kV, 800A, 26.3kA Half Panel without CT, PT

12kV, 630A, 26.3kA Subcubicle

600

METERINGCOMPARTMENT

FDR

800AVCB

21

95

1570

21

70

BREAKERCOMPARTMENT

BUSBARCOMPARTMENT

R

Y

B

CABLE COMPARTMENT

METERING

COMPARTMENT

BREAKER COMPARTMENT

600

BREAKERCOMPARTMENT

16

19

12

26

METERINGCOMPARTMENT

SHUTTERBUSBAR

COMPARTMENT

CABLINGCOMPARTMENT

1012

DIMENSIONAL DRAWING9

12kV, 800A, 40kA Full Panel with PT

12kV, 800A, 40kA Full Panel without PT

6002

49

5

BREAKER COMPARTMENT

METERINGCOMPARTMENT

1570

21

70

METERINGCOMPARTMENT

BREAKERCOMPARTMENT

BUSBARCOMPARTMENT

R Y

B

WINDOWCT

LINEVT

FDR

800A VCB

CABLE COMPARTMENT

600

24

95

BREAKER COMPARTMENT

METERINGCOMPARTMENT

FDR

1570

21

70

METERINGCOMPARTMENT

BREAKER COMPARTMENT

BUSBARCOMPARTMENT

R Y

B

WINDOWCT

800A VCB

CABLE COMPARTMENT

DIMENSIONAL DRAWING 10

12kV, 800A, 40kA ICOG Full Panel with PT

12kV, 800A, 40kA ICOG Half Panel without CT, PT

600

METERING

COMPARTMENT

800AVCB

24

95

1970

21

70

BREAKER COMPARTMENT

BUSBAR COMPARTMENT

BREAKERCOMPARTMENT

CABLE COMPARTMENT

METERING

COMPARTMENT

600

METERINGCOMPARTMENT

FDR

800AVCB

24

95

1970

21

70

WOUND CT

BREAKER COMPARTMENT

BREAKERCOMPARTMENT

CABLE COMPARTMENT

METERING

COMPARTMENT

BUSBAR COMPARTMENT

DIMENSIONAL DRAWING11

33kV, 800A, 31.5kA Standard Half Panel without PT, CT

800A VCB

METERINGCOMPARTMENT

1000

25

00

2650

30

40

BREAKER COMPARTMENT

METERING

COMPARTMENT

BREAKERCOMPARTMENT

BUSBARCOMPARTMENT

RY

B

CABLE COMPARTMENT

33kV, 800A, 31.5kA Standard Full Panel with PT

1000

METERINGCOMPARTMENT

FDR

800A VCB

25

00

2650

30

40

BUSBARCOMPARTMENT

PT

WOUNDCT

METERING

COMPARTMENT

BREAKERCOMPARTMENT

BUSBARCOMPARTMENT

BREAKER COMPARTMENT

CABLE COMPARTMENT

RY

B

DIMENSIONAL DRAWING 12

33kV, 800A, 31.5kA ICOG Half Panel without PT, CT

33kV, 800A, 31.5kA ICOG Full Panel with PT

1000

GA

SD

UC

TO

UT

LE

T

METERINGCOMPARTMENT

FDR

800A VCB

25

00

3250

30

40

INC

OM

ING

P

OW

ER

C

AB

LE

S

OU

TG

OIN

GP

OW

ER

C

AB

LE

S

BUSBAR COMPARTMENT

BREAKERCOMPARTMENT

CABLE COMPARTMENT

METERING

COMPARTMENT

BREAKER COMPARTMENT

* All Dimensions are in mm

800A VCB

METERINGCOMPARTMENT

1000

GA

SD

UC

TO

UT

LE

T

25

00

3250

INC

OM

ING

P

OW

ER

C

AB

LE

S

OU

TG

OIN

GP

OW

ER

C

AB

LE

SBREAKERCOMPARTMENT

BUSBAR COMPARTMENT

CABLE COMPARTMENT

BREAKERCOMPARTMENT

30

40

OPTIONAL ACCESSORIES

• Annunciator & Hooter

• Power pack with inbuilt battery backup

• Earthing Truck

Bus earthing truck & Line/Cable earthing truck are available with safety interlocks

• Earthing Switch

Integral earthing switch can be provided for earthing cable/line. Bus earthing switch for busbar side

will also provided. Earth switch are provided with full making capacity

Surge arresters

Earthing Switch Earthing Truck

Current Rating (A)

Rated voltage Dimensions

12kV(26.3kA/40kA)

24kV & 36kV*(31.5kA)

Width (mm)

Depth (mm)

Height (mm)

Width (mm)

Depth (mm)

Height (mm)

600

1570

2195

1000

2650

2500

600

1570

2195

1000

2650

2500

800

1970

2195

1000

2650

2500

1000

1970

2195

800 1250 2000 3150

• Height will change depending on components of LV compartment.

* 36kV VCB will be provided for 24kV VCB requirement.

Depth will vary with the no. & size of cable & current transformers.

DIMENSIONS13

ORDERING PARAMETERS

2. BREAKER RACK IN/RACK OUT INTERLOCKS

• VCB cannot be racked in/out when it is in closed position and is possible only when it is in open position

• VCB can be closed only when it is either in test or service position

• VCB cannot be closed in the intermediate position

3. EARTHING SWITCH INTERLOCKS

4. OTHER INTERLOCKS

• Earthing switch cannot be closed when VCB is in service position

• VCB cannot be racked in from isolated or test position to service position when earthing switch is closed

• Earthing switch can be closed only when VCB is in isolated or test position

• VCB cannot be closed electrically unless spring is fully charged

• VCB compartment door cannot be opened when VCB is in service & intermediate position & can be opened

only when the VCB is in test / isolated position

• Safety shutter opens automatically when the VCB is racked in the service position

• Safety shutter closes automatically when the VCB is racked out from the service position

• Rear door interlock can be provided on request. Rear door cannot be opened when the VCB is in

service & intermediate position and can be opened only when the VCB is in test/isolated position

or taken out from panel.

* For subcubicle control supply voltage should be mention during ordering.

SAFETY INTERLOCKS 14

1. SECONDARY DISCONNECTING SWITCH (SDS) INTERLOCKS

• VCB cannot be racked in unless the SDS plug is inserted

• SDS plug cannot be removed when VCB is in service or intermediate position

• SDS plug can be removed only when the VCB is in test or isolated position

Application

Voltage

Current Rating (A)

Short Circuit BreakingCapacity

Panel Options

Panel Version

Frequency

Busbar Type

CT Details

PT Details

Meters

Control Supply Voltage

12kV 24kV 36kV

630, 800,1250, 2000

26.3kA 40kA / 50kA

800, 1250,2000, 3150

31.5kA 31.5kA

800, 1250, 2000 800, 1250, 2000

Full Panel/Half Panel/ICOG/Subcubicle*

With PT/Without PT

50 Hz

Copper/Aluminium

Ratio/VA rating/Accuracy Class

Ratio/ /Accuracy ClassVA rating

A/V/MFM/TVM/Other

24/110/220V DC or 110/230V AC

Feeder/Transformer/Motor/Capacitor/Generator Protection/Other

• VCU available upto current rating 400A & Voltage rating 7.2kV

(12kV VCU will be offered on request)

• Fused short circuit protection up to 50kA

• Available in latched & non latched configurations

• Encapsulated current carrying parts for higher safety

• Truck mounted design similar to draw out VCB

• Suitable for motor starters with numerous switching operations

• Two VCUs can be accommodated in single panel for optimum

space utilisation

• VCU panels can be coupled with VCB panels owing to similar

dimensions

15 VACUUM CONTACTOR UNIT

# 2 Tier Panel width & depth starts from 800 mm & 1970 mm respectively*12kV VCU will be offered on request.

Standards

Type Designation

Voltage

Power Frequency Withstand Voltage

Impulse Withstand Voltage

Frequency

Rated Current

Short Time Withstand Current

Short Time Withstand Current (with Fuse)

Width#

Depth#

Height

Partition Class

Loss of Service continuity

Degree of Protection

Damage Classification

Internal Arc Classification

IEC Standard

VCU Type

Type Designation

Opening time

Mechanical Endurance

Electrical Endurance

Rated Duties (40% on Load Factor)

Closing/Tripping Coil

Auxiliary Contacts

IEC 62271-200

VH1H

up to 7.2kV*

20 kVrms

60 kVp

50 / 60 Hz

200 - 400 A

up to 8kA

25 / 40 / 50kA

600 MM

1570 / 1970 MM

2195 / 2495 MM

PM

LSC-2B

IP4X (Higher IP on request)

Type C

A (F, L, R), 40kA, upto 1s

IEC 62271-106

<35 ms

upto 0.3 Million (AC-3)

Class 300

110 / 220 V DC

3NO + 3NC

Panel Details

Voltage Ratings

Current Ratings

Dimensions

Construction

VCU

Non Latched Latched

VCU7N200 VCU7N400 VCU7L200 VCU7L400

upto 3 Million upto 0.3 Million

7.2kV AIS with VCU

16TECHNICAL SPECIFICATIONS

Notes:

Please contact any of the training centres for participation and detailed training programme schedule.

So gain the advantage and go the extra mile with:�

The typical training programmes cover:

22 courses on contemporary topicsCourses applicable to all switchgear brandsTraining Centers in Pune, Lucknow, Coonoor, Vadodara, Delhi & KolkataBlend of theory and practical experience

Low Voltage & Medium Voltage Switchgear

Switchboard Electrical Design

AC Drives & Building Management Solutions

Protective Relays & Earthing

Power Quality Solutions

Pune

Larsen & Toubro LimitedSwitchgear Training Centre, T-156/157, MIDCBhosari, Pune - 411 026Tel: 020 2712 0037 / 2712 0653 Fax: 020 2712 2933 E-mail: [email protected]

Lucknow

Larsen & Toubro LimitedSwitchgear Training Centre, C - 6 & 7, UPSIDCP. O. Sarojininagar, Lucknow - 226 008Tel: 0522 247 6015 / 97944 54455 Fax: 0522 247 6015 E-mail: [email protected]

Coonoor

Larsen & Toubro LimitedSwitchgear Training Centre, Ooty-Coonoor Main RoadYellanahalli P.O., The Nilgiris - 643 243Tel. : 0423 251 7107Fax : 0423 251 7158E-mail: [email protected]

Vadodara

Larsen & Toubro LimitedSwitchgear Training CentreBehind L&T Knowledge City, Near Village Ankhol, Vadodara - 390019Tel: 0265 2457805E-mail: [email protected]

Delhi

Larsen & Toubro LtdSwitchgear Training Centre32, Shivaji Marg,Near Motinagar Metro Station,New Delhi - 110015 Tel: 011 41419515 / 41419695 / 41419500Fax: 011 41419600E-mail: [email protected]

Kolkata

Larsen & Toubro LimitedSwitchgear Training Centre4th Floor, 3B, Shakespeare Sarani, Kolkata - 700071Tel: 033 42005975 / 42005978E-mail: [email protected]

Aimed at maximizing productivity, conserving energy, minimizing costs and enhancing safety, our Electrical

& Automation training programmes have benefitted over 1.35 Lakh professionals in the last 28 years. These

training programmes are highly beneficial as they provide right exposure and impart knowledge on

selection, installation, maintenance and testing of Electrical & Automation Products.

Khairasol, Degaul AvenueDurgapur 713 212Tel: 0343-2540448 / 2540449 / 2540443Fax: 0343-2540442e-mail: [email protected]

5, Milanpur Road, Bamuni MaidanGuwahati 781 021Tel: +91 8876554410 / 8876554417Fax: 361-2551308e-mail: [email protected]

II Floor, Vasantha Chambers5-10-173, Fateh Maidan RoadHyderabad 500 004Tel: 040-67015052Fax: 040-23296468e-mail: [email protected]

Monarch Building, 1st FloorD-236 & 237, Amrapali MargVaishali NagarJaipur 302 021Tel: 0141-4385914 to 18Fax: 0141-4385925e-mail: [email protected]

Akashdeep Plaza, 2nd FloorP. O. GolmuriJamshedpur 831 003JharkhandTel: 0657-2312205 / 38Fax: 0657-2341250e-mail: [email protected]

Skybright Bldg; M. G. RoadRavipuram Junction, ErnakulamKochi 682 016Tel: 0484-4409420 / 4 / 5 / 7Fax: 0484-4409426e-mail: [email protected]

3-B, Shakespeare SaraniKolkata 700 071Tel: 033-42005982Fax: 033-22821025 / 7587e-mail: [email protected]

A28, Indira Nagar, Faizabad Road Lucknow 226 016Tel: 0522-4929905 / 04Fax: 0522-2311671e-mail: [email protected]

No: 73, Karpaga Nagar, 8th StreetK. PudurMadurai 625 007Tel: 0452-2567405 / 2561068 / 2561657Fax: 0452-2567552e-mail: [email protected]

Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here.

Electrical Standard Products (ESP) Offices:

HEAD OFFICEL&T Business Park,Tower 'B' / 3rd FloorSaki Vihar Road, PowaiMumbai 400 072Tel: 022-67053229 Fax: 022-67051112e-mail: [email protected]

BRANCH OFFICES501, Sakar Complex I Opp. Gandhigram Rly. Station Ashram RoadAhmedabad 380 009Tel: 079-66304006-11Fax: 079-66304025e-mail: [email protected]

38, Cubbon Road, P. O. Box 5098Bengaluru 560 001Tel: 080-25020100 / 25020324Fax: 080-25580525e-mail: [email protected]

131/1, Zone IIMaharana Pratap NagarBhopal 462 011Tel: 0755-3080511 / 05 / 08 / 13 / 17 / 19 Fax: 0755-3080502e-mail: [email protected]

Plot No. 559, Annapurna ComplexLewis RoadBhubaneswar 751 014Tel: 0674-6451342 / 2436690 / 2436696Fax: 0674-2537309e-mail: [email protected]

Aspire Towers, 4th FloorPlot No. 55, Phase-IIndustrial & Business ParkChandigarh-160 002Tel: 0172-4646840 / 41 / 42 / 46 / 53Fax: 0172-4646802Email: [email protected]

L&T Construction CampusTC-1 Building, II FloorMount-Poonamallee RoadManapakkamChennai 600 089Tel: 044-2270 6800Fax: 044-22706940e-mail: [email protected]

67, Appuswamy RoadPost Bag 7156 Opp. Nirmala CollegeCoimbatore 641 045Tel: 0422-2588120 / 1 / 5Fax: 0422-2588148e-mail: [email protected]

L&T Business Park,Tower 'B' / 5th FloorSaki Vihar Road, PowaiMumbai 400 072Tel: 022-67052874 / 2737 / 1156Fax: 022-67051112e-mail: [email protected]

12, Shivaji NagarNorth Ambajhari RoadNagpur 440 010Tel: 0712-2260012 / 6606421Fax: 2260030 / 6606434e-mail: [email protected]

32, Shivaji Marg P. O. Box 6223New Delhi 110 015Tel: 011-41419514 / 5 / 6Fax: 011-41419600e-mail: [email protected]

L&T House P. O. Box 119 191/1, Dhole Patil RoadPune 411 001Tel: 020-66033395 / 66033279Fax: 020-26164048 / 26164910e-mail: [email protected]

Crystal Tower, 4th Floor, G. E. RoadTelibandhaRaipur - 492 006Tel: 0771-4283214e-mail: [email protected]

3rd Floor Vishwakarma ChambersMajura Gate, Ring RoadSurat 395 002Tel: 0261-2473726Fax: 0261-2477078e-mail: [email protected]

Radhadaya ComplexOld Padra RoadNear Charotar SocietyVadodara 390 007Tel: 0265-6613610 / 1 / 2Fax: 0265-2336184e-mail: [email protected]

Door No. 49-38-14/3/2, 1st floor,NGGO's Colony, Akkayyapalem,Visakhapatnam - 530 016Tel: 0891-2791126 / 2711125Fax: 0891-2791100Email: [email protected]

Larsen & Toubro Limited, Electrical Standard Products

Powai Campus, Mumbai 400 072

Customer Interaction Center (CIC)

BSNL / MTNL (toll free) : 1800 233 5858 Reliance (toll free) : 1800 200 5858

Tel : 022 6774 5858, Fax : 022 6774 5859

E-mail : [email protected] / Website www.Lntebg.com

Registered Office: L&T House, N. M. Marg, Ballard Estate, Mumbai 400 001, INDIA CIN: L99999MH1946PLC004768

SP 50604 R3