Post on 04-May-2023
Ayanda
Biosystems SA
PSE Parc ScientifiqueEPFLCH-1015 LausanneSwitzerland
Phone/Fax: +41 21 693 8631info@ayanda-biosys.comhttp://www.ayanda-biosys.com
Ayanda™ MEA Biochips
Product Catalog
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 100 3D
Substrate dimension: 15 mm x 15 mm x 0.6 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 60Electrode material: platinumElectrode geometry: 3DElectrode height: 25-35 µmElectrode layout: 8 x 8 matrix without corner
electrodesElectrodes dimension: ø 30 µm circular electrodesElectrode spacing: 100 µm centre to centreImpedance @ 1 kHz: 600-900 kΩNoise level: 15-20 µVRe-use: up to 100 times when usingwith acute tissue slices, severaltimes when used for organotypic
cultures.Required accessories: MEA60 Spa-Y1 or
MEA60 Spa-Y2
Characteristics
Acute slice preparations and organotypic slice cultures(brain tissue, spinal cord, retina, etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 100 Au
Substrate dimension: 15 mm x 15 mm x 0.7 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 60Electrode material: goldElectrode geometry: planarElectrode layout: 8 x 8 matrix without corner
electrodesElectrodes dimension: ø 30 µm circular electrodesElectrode spacing: 100 µm centre to centreImpedance @ 1 kHz: 1000-1300 kΩNoise level: 25-30 µVRe-use: several times depending ontype and duration of cultures.Required accessories: MEA60 Spa-Y1 or
MEA60 Spa-Y2
Characteristics
Organotypic slice cultures and dissociated cell cultures(brain tissue, spinal cord, retina, heart muscle cells,etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 100 Pt
Substrate dimension: 15 mm x 15 mm x 0.7 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 60Electrode material: platinumElectrode geometry: planarElectrode layout: 8 x 8 matrix without corner
electrodesElectrodes dimension: ø 30 µm circular electrodesElectrode spacing: 100 µm centre to centreImpedance @ 1 kHz: 800-1100 kΩNoise level: 20-25 µVRe-use: several times depending ontype and duration of cultures.Required accessories: MEA60 Spa-Y1 or
MEA60 Spa-Y2
Characteristics
Organotypic slice cultures and dissociated cell cultures(brain tissue, spinal cord, retina, heart muscle cells,etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 200 3D
Substrate dimension: 15 mm x 15 mm x 0.6 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 60Electrode material: platinumElectrode geometry: 3DElectrode height: 50-70 µmElectrode layout: 8 x 8 matrix without corner
electrodesElectrodes dimension: 40 µm x 40 µm squareelectrodesElectrode spacing: 200 µm centre to centreImpedance @ 1 kHz: 250-450 kΩNoise level: 15-20 µVRe-use: up to 100 times when usingwith acute tissue slices, severaltimes when used for organotypic
cultures.Required accessories: MEA60 Spa-Y1 or
MEA60 Spa-Y2
Characteristics
Acute slice preparations and organotypic slice cultures(brain tissue, spinal cord, retina, etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 200 3D GND
Substrate dimension: 15 mm x 15 mm x 0.6 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 60 (59 recording electrodes and
1 large GND electrode)Electrode material: platinumElectrode geometry: 3DElectrode height: 50-70 µmElectrode layout: 8 x 8 matrix without corner
electrodesElectrodes dimension: ø 40 µm circular electrodesElectrode spacing: 200 µm centre to centreImpedance @ 1 kHz: 250-450 kΩ, GND < 2 kΩNoise level: 15-20 µVRe-use: up to 100 times when usingwith acute tissue slices, severaltimes when used for organotypic
cultures.Required accessories: MEA60 Spa-Y1 or
MEA60 Spa-Y2
Characteristics
Acute slice preparations and organotypic slice cultures(brain tissue, spinal cord, retina, etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 200 Au
Substrate dimension: 15 mm x 15 mm x 0.7 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 60Electrode material: goldElectrode geometry: planarElectrode layout: 8 x 8 matrix without corner
electrodesElectrodes dimension: 40 µm x 40 µm squareelectrodesElectrode spacing: 200 µm centre to centreImpedance @ 1 kHz: 600-800 kΩNoise level: 25-30 µVRe-use: several times depending ontype and duration of cultures.Required accessories: MEA60 Spa-Y1 or
MEA60 Spa-Y2
Characteristics
Organotypic slice cultures and dissociated cell cultures(brain tissue, spinal cord, retina, heart muscle cells,etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 200 ITO
Substrate dimension: 15 mm x 15 mm x 0.7 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 60Electrode material: ITO (indium-tin oxide), a
transparent conductive metal oxide
Electrode geometry: planarElectrode layout: 8 x 8 matrix without corner
electrodesElectrodes dimension: 40 µm x 40 µm squareelectrodesElectrode spacing: 200 µm centre to centreImpedance @ 1 kHz: 1000-1300 kΩNoise level: 30-40 µVRe-use: several times depending ontype and duration of cultures.Required accessories: MEA60 Spa-Y1 or
MEA60 Spa-Y2
Characteristics
Organotypic slice cultures and dissociated cell cultures(brain tissue, spinal cord, retina, heart muscle cells,etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 200 Pt
Substrate dimension: 15 mm x 15 mm x 0.7 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 60Electrode material: platinumElectrode geometry: planarElectrode layout: 8 x 8 matrix without corner
electrodesElectrodes dimension: 40 µm x 40 µm squareelectrodesElectrode spacing: 200 µm centre to centreImpedance @ 1 kHz: 400-600 kΩNoise level: 20-25 µVRe-use: several times depending ontype and duration of cultures.Required accessories: MEA60 Spa-Y1 or
MEA60 Spa-Y2
Characteristics
Organotypic slice cultures and dissociated cell cultures(brain tissue, spinal cord, retina, heart muscle cells,etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 200 Pt GND
Substrate dimension: 15 mm x 15 mm x 0.7 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 60 (59 recording electrodes and
1 large GND electrode)Electrode material: platinumElectrode geometry: planarElectrode layout: 8 x 8 matrix without corner
electrodesElectrodes dimension: ø 40 µm circular electrodesElectrode spacing: 200 µm centre to centreImpedance @ 1 kHz: 500-650 kΩNoise level: 20-25 µV, GND < 2 kΩRe-use: several times depending ontype and duration of cultures.Required accessories: MEA60 Spa-Y1 or
MEA60 Spa-Y2
Characteristics
Organotypic slice cultures and dissociated cell cultures(brain tissue, spinal cord, retina, heart muscle cells,etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 200 Pt/ITO
Substrate dimension: 15 mm x 15 mm x 0.7 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 60Electrode material: platinumElectrode leads: ITO (indium-tin oxide), a
transparent conductive metal oxide
Electrode geometry: planarElectrode layout: 8 x 8 matrix without corner
electrodesElectrodes dimension: 40 µm x 40 µm squareelectrodesElectrode spacing: 200 µm centre to centreImpedance @ 1 kHz: 400-600 kΩNoise level: 20-25 µVRe-use: several times depending ontype and duration of cultures.Required accessories: MEA60 Spa-Y1 or
MEA60 Spa-Y2
Characteristics
Organotypic slice cultures and dissociated cell cultures(brain tissue, spinal cord, retina, heart muscle cells,etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 5x13 3D
Substrate dimension: 15 mm x 15 mm x 0.6 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 60Electrode material: platinumElectrode geometry: 3DElectrode height: 35-45 µmElectrode layout: 5 x 13 matrixElectrodes dimension: ø 40 µm circular electrodesElectrode spacing: 140 µm and 200 µm centre to
centreImpedance @ 1 kHz: 350-500 kΩNoise level: 15-20 µVRe-use: up to 100 times when usingwith acute tissue slices, severaltimes when used for organotypic
cultures.Required accessories: MEA60 Spa-Y1 or
MEA60 Spa-Y2
Characteristics
Acute slice preparations and organotypic slice cultures(brain tissue, spinal cord, retina, etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 5x13 Au
Substrate dimension: 15 mm x 15 mm x 0.7 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 60Electrode material: goldElectrode geometry: planarElectrode layout: 5 x 13 matrixElectrodes dimension: ø 40 µm circular electrodesElectrode spacing: 140 µm and 200 µm centre to
centreImpedance @ 1 kHz: 700-900 kΩNoise level: 25-30 µVRe-use: several times depending ontype and duration of cultures.Required accessories: MEA60 Spa-Y1 or
MEA60 Spa-Y2
Characteristics
Organotypic slice cultures and dissociated cell cultures(brain tissue, spinal cord, retina, heart muscle cells,etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 5x13 Pt
Substrate dimension: 15 mm x 15 mm x 0.7 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 60Electrode material: platinumElectrode geometry: planarElectrode layout: 5 x 13 matrixElectrodes dimension: ø 40 µm circular electrodesElectrode spacing: 140 µm and 200 µm centre to
centreImpedance @ 1 kHz: 500-650 kΩNoise level: 20-25 µVRe-use: several times depending ontype and duration of cultures.Required accessories: MEA60 Spa-Y1 or
MEA60 Spa-Y2
Characteristics
Organotypic slice cultures and dissociated cell cultures(brain tissue, spinal cord, retina, heart muscle cells,etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 200 Pt 21x21
Substrate dimension: 21 mm x 21 mm x 0.7 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 72 (60 recording electrodes, 8
stimulation electrodes, 4 GNDelectrodes)
Electrode material: platinumElectrode geometry: planarElectrode layout: 8 x 8 matrix without corner
electrodesElectrodes dimension: 40 µm x 40 µm squareelectrodesElectrode spacing: 200 µm centre to centreImpedance @ 1 kHz: 400-600 kΩ, stimulation
electrodes 50-90 kΩ, GND < 10 kΩ
Noise level: 20-25 µVRe-use: several times depending ontype and duration of cultures.Required accessories: MEA60 Spa-Y2 and
MEA1060-Y1 or MEA1060-Y2depending on MEA1060
amplifier f rom Mult iChannel
Characteristics
Organotypic slice cultures and dissociated cell cultures(brain tissue, spinal cord, retina, heart muscle cells,etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 4Wells
Substrate dimension: 21 mm x 21 mm x 0.7 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 72 (60 recording electrodes, 8
stimulation electrodes, 4 GNDelectrodes)
Electrode material: platinumElectrode geometry: planarElectrode layout: 4x4 matrix without 1 corner
electrodeElectrodes dimension: ø 40 µmElectrode spacing: 200 µm centre to centreImpedance @ 1 kHz: 500-700 kΩ, stimulation
electrodes 20-30 kΩ, GND 500 Ω
Noise level: 20-25 µVRe-use: several times depending on
type and duration of cultures.Required accessories: MEA60 Spa-Y2 and
MEA1060-Y1 or MEA1060-Y2depending on MEA1060 amplifier from Multi Channel Systems MCS GmbH
Characteristics
Dissociated cell cultures (brain tissue, spinal cord,retina, heart muscle cells, etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 4x15 3D (size 1)
Substrate dimension: 21 mm x 21 mm x 0.55 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 72 (60 recording electrodes, 8
stimulation electrodes, 4 GNDelectrodes)
Electrode material: platinumElectrode geometry: 3DElectrode height: 60-80 µmElectrode layout: 4 x 15 matrixElectrodes dimension: ø 80 µm circular electrodesElectrode spacing: X axis: 250 µm, Y axis: 750 µm
centre to centreImpedance @ 1 kHz: 80-150 kΩ, stimulation
electrodes 50-90 kΩ, GND < 10 kΩ
Noise level: 10-15 µVRe-use: several times depending ontype and duration of cultures.Required accessories: MEA60 Spa-Y2 and
MEA1060-Y1 or MEA1060-Y2depending on MEA1060
amplifier f rom Mult iChannel
Characteristics
Organotypic slice cultures and dissociated cell cultures(brain tissue, spinal cord, retina, heart muscle cells,etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 4x15 3D (size 2)
Substrate dimension: 21 mm x 21 mm x 0.55 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 72 (60 recording electrodes, 8
stimulation electrodes, 4 GNDelectrodes)
Electrode material: platinumElectrode geometry: 3DElectrode height: 60-80 µmElectrode layout: 4 x 15 matrixElectrodes dimension: ø 80 µm circular electrodesElectrode spacing: X axis: 300 µm, Y axis: 900 µm
centre to centreImpedance @ 1 kHz: 80-150 kΩ, stimulation
electrodes 50-90 kΩ, GND < 10 kΩ
Noise level: 10-15 µVRe-use: several times depending ontype and duration of cultures.Required accessories: MEA60 Spa-Y2 and
MEA1060-Y1 or MEA1060-Y2depending on MEA1060
amplifier f rom Mult iChannel
Characteristics
Organotypic slice cultures and dissociated cell cultures(brain tissue, spinal cord, retina, heart muscle cells,etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 4x15 3D (size 3)
Substrate dimension: 21 mm x 21 mm x 0.55 mmSubstrate material: float glassInsulation material: SU-8 epoxy, thickness 5 µmNumber of electrodes: 72 (60 recording electrodes, 8
stimulation electrodes, 4 GNDelectrodes)
Electrode material: platinumElectrode geometry: 3DElectrode height: 60-80 µmElectrode layout: 4 x 15 matrixElectrodes dimension: ø 80 µm circular electrodesElectrode spacing: X axis: 400 µm, Y axis: 1000µm centre to centreImpedance @ 1 kHz: 80-150 kΩ, stimulation
electrodes 50-90 kΩ, GND < 10 kΩ
Noise level: 10-15 µVRe-use: several times depending ontype and duration of cultures.Required accessories: MEA60 Spa-Y2 and
MEA1060-Y1 or MEA1060-Y2depending on MEA1060
amplifier f rom Mult iChannel
Characteristics
Organotypic slice cultures and dissociated cell cultures(brain tissue, spinal cord, retina, heart muscle cells,etc.)
Applications
Product typeMulti-electrode array biochip compatible with theMEA60 data acquisition system from Multi ChannelSystems MCS GmbH, Reutlingen, germany.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 Spa-Y1
Printed Circuit Board that is required for save handlingof Ayanda™ MEA60 Biochips. It has to be placed atbottom of MEA1060 amplifier from Multi ChannelSystems MCS GmbH, Germany.
Adapted to all Ayanda™ MEA60 Biochips based on15 mm x 15 mm glass substrates.
Dimensions: 49 mm x 49 mm x 0.7 mmHole: ø 25 mm
Characteristics
Avoids MEA60 biochip irreversible damage whileplaced in the MCS MEA1060 amplifier.
Applications
Product typeSpacer for multi-electrode array biochip.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA60 Spa-Y2
Printed Circuit Board that is required for save handlingof Ayanda™ MEA60 Biochips. It has to be placed atbottom of MEA1060 amplifier from Multi ChannelSystems MCS GmbH, Germany.
Adapted to all Ayanda™ MEA60 Biochips.
Dimensions: 49 mm x 49 mm x 0.7 mmHole: ø 33 mm
Characteristics
Avoids MEA60 biochip irreversible damage whileplaced in the MCS MEA1060 amplifier.
Applications
Product typeSpacer for multi-electrode array biochip.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA1060-Y1
Small printed circuit board that is fixed on theMEA1060-1 amplifier for inverted microscopes fromMulti Channel Systems MCS GmbH, Germany.
Allows connection to 8 supplementary stimulationelectrodes (4 pairs of 2) and 4 substrate integratedGND electrodes for Ayanda™ MEA60 Biochips basedon large (21x21 mm2) substrates.
Allows connection of 2 supplementary wires to GND.
Dimensions: 34 mm x 34 mm x 22 mm
Characteristics
Allows connection to supplementary MEA60 biochipintegrated GND and stimulaiton electrodes.
Applications
Product typeAccessory for connection of supplementary GND andstimulation electrodes.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
MEA1060-Y2
Printed circuit board that is fixed on the MEA1060-2amplifier for upright microscopes from Multi ChannelSystems MCS GmbH, Germany.
Allows connection to 8 supplementary stimulationelectrodes (4 pairs of 2) and 4 substrate integratedGND electrodes for Ayanda™ MEA60 Biochips basedon large (21x21 mm2) substrates.
Allows connection of 8 supplementary wires to GND.
Dimensions: 103 mm x 103 mm x 22 mm
Characteristics
Allows connection to supplementary MEA60 biochipintegrated GND and stimulaiton electrodes.
Applications
Product typeAccessory for connection of supplementary GND andstimulation electrodes.
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com
Innovative diagnostic and drug discovery toolsAyanda BiosystemsAyanda Biosystems
Custom Designed MEA Biochips
We can also offer upon request user-specific solutions interms of MEA-layout configuration. Ayanda™ MEAbiochips can be adapted to other amplification and dataacquisition systems.
We would be pleased to provide a quote upon request.
There would be some tooling costs and the minimum orderquantity is 25 MEA biochips.
Price of MEA biochips corresponds to price of similarexisting MEA biochips.
Characteristics
Dissociated cell culturesOrganotypic culturesAcute tissue slices ...
Applications
Product typeCustom layout MEA biochips
Ayanda Biosystems S.A., PSE Parc Scientifique, Building C, EPFL, CH-1015 Lausanne, SwitzerlandTel / fax: +41 21 693 8631; Email: info@ayanda-biosys.com; Internet: www.ayanda-biosys.com