WiseWay
Software User Manual Contents
iii
Foreword
Summaries
Thank you for choosing the WiseWay software product!
This document mainly introduces the installation and operation of the WiseWay software product.
Please save the information after reading, in order to consult in the future.
Term Convention
Abbreviation Description
SNMP Simple Network Management Protocol
HTTP HyperText Transfer Protocol
Web Browser Web browser, i.e. webpage browser
TCP Transmission Control Protocol
UDP User Datagram Protocol
DHCP Dynamic Host Configuration Protocol
DNS Domain Name System
FTP File Transfer Protocol
ARP Address Resolution Protocol
WiseWay
Software User Manual Contents
iv
Contents
1 Overview......................................................................................................................................... 1
1.1 System Overview ............................................................................................................................................... 1
2 Hardware Overview ..................................................................................................................... 2
2.1 Appearance of SNMP card ................................................................................................................................. 2
2.2 Function Description for Hardware Port ........................................................................................................... 2
2.3 LED Signal Indicator ........................................................................................................................................ 2
3 Software Overview ....................................................................................................................... 4
3.1 Application ........................................................................................................................................................ 4
3.2 Software Detailed List ...................................................................................................................................... 4
3.3 Software Environment....................................................................................................................................... 5
4 First Use SNMP Card ................................................................................................................... 6
4.1 First Login ......................................................................................................................................................... 6
4.2 Account Number Setting .................................................................................................................................... 7
5 Use Guide ....................................................................................................................................... 8
5.1 Main Page Information...................................................................................................................................... 8
5.1.1 Real Time Status of UPS ......................................................................................................................... 9
5.1.2 UPS Current Running Data ..................................................................................................................... 9
5.1.3 UPS Current Running Status .................................................................................................................10
5.2 UPS Information and Status ............................................................................................................................11
5.2.1 System Information and Status ...............................................................................................................11
5.2.2 UPS Basic Information ..........................................................................................................................13
5.2.3 UPS Real-time Data ..............................................................................................................................14
5.2.4 UPS Real-time Status ............................................................................................................................16
5.2.5 Module Real-time Status .......................................................................................................................18
5.2.6 Chart Display .........................................................................................................................................20
5.3 Setting and Control .........................................................................................................................................21
WiseWay
Software User Manual Contents
v
5.3.1 Remote Control ......................................................................................................................................21
5.3.2 UPS Parameters Setting .........................................................................................................................22
5.3.3 UPS ON/OFF .........................................................................................................................................25
5.3.4 Wake on LAN ........................................................................................................................................26
5.3.5 Network Setting .....................................................................................................................................27
5.3.6 SNMP Configuration .............................................................................................................................29
5.3.7 Email Setting..........................................................................................................................................32
5.3.8 SMS Setting............................................................................................................................................34
5.3.9 485 Bus Module Setting ........................................................................................................................37
5.3.10 System Setting ......................................................................................................................................37
5.4 Log Query .......................................................................................................................................................38
5.4.1 Event Log ..............................................................................................................................................39
5.4.2 SMS Log ................................................................................................................................................39
5.4.3 UPS Data ...............................................................................................................................................40
5.5 Other Functions ...............................................................................................................................................41
5.5.1 Firmware Update ...................................................................................................................................41
5.5.2 Port Debug .............................................................................................................................................43
5.6 About ...............................................................................................................................................................43
WiseWay
Software User Manual 1Overview
1
1 Overview
1.1 System Overview
SNMP card is a new network monitoring product which is designed to manage the UPS conveniently.
The product provides real time network monitoring and management for UPS, and it can also look up
the real time dynamic data to realize the remote control of UPS, which make the networked
management for UPS more convenient. The product can realize the monitoring for single UPS,
matching with corresponding PC software, it can achieve integration monitoring management.
SNMP card provides speedy installation procedure, you can search and set the IP address after
installing the NetFind software in PC. Login the webpage of SNMP card through browser (such as IE
browser), and you can obtain the operating status of UPS, such as working voltage, current,
frequency, temperature, humidity, etc. of UPS. Through Web interface, you can set the parameters of
device and system, such as start or shut down the UPS in a certain time, set the user authority, user
name, IP, etc.
SNMP card provides close software for different operating system. If necessary, please close the
operating system to avoid abnormal shutdown caused by mains abnormal.
WiseWay
Software User Manual 2Hardware Overview
2
2. Hardware Overview
2.1 Appearance of SNMP card
Figure2 -1 Appearance of SNMP card
2.2 Function Description for Hardware Port
Table2-1 Function description for hardware port
Picture Name Function
NETWORK port
Ethernet port
2.3 LED Signal Indicator
Table2-2 Corresponding signal indicator status of SNMP card
Red indicator Yellow indicator Green indicator Status description
Off Off Continuously lighting on System starting
WiseWay
Software User Manual 2Hardware Overview
3
Red indicator Yellow indicator Green indicator Status description
* * Flickers (once per second) System running
* * Flickers (twice per second) System running
* Flickers (once per
second)
Flickers (once per second) UPS is in communicating
Off Continuously
lighting on
Flickers (once per second) UPS is judging the
overtime
Continuously
lighting on
Off Flickers (once per second) UPS lost connection
Off/
Continuously
lighting on
Off/ Continuously
lighting on
Off/ Continuously lighting
on
System fault
* means that the indicator stay in random status.
WiseWay
Software User Manual 3Software Overview
4
3. Software Overview
3.1 Application
SNMP card is a new network monitoring product which is designed to manage the UPS conveniently.
Login the webpage of SNMP card through browser (such as IE browser), and you can obtain the
operating status of UPS, such as work voltage, current, frequency, temperature, humidity, etc. of UPS.
Through Web interface, you can set the parameters of device and system, such as start or shut down
the UPS in a certain time, set the user authority, user name, IP, etc.
The detailed function is as follows.
Monitor the real time status of UPS through browser to login SNMP card.
Set the function of UPS through browser to login SNMP card.
Support the protocol of TCP/IP, SNMP, FTP, NTP, HTTP, SMTP, etc.
Provide software (WiseFind) to upgrade the SNMP card.
Send daily report forms by Email.
When UPS abnormal, administrator can receive related information through message, SNMP,
Email, etc.
It can attach message module to achieve message alarm.
3.2 Software Detailed List
User manual for SNMP card
Installation program for WiseFind searching software.
Installation program for WiseClose shutdown software.
Installation program for WiseSMS message server
Installation program for WiseInsight integration monitoring software
WiseWay
Software User Manual 3Software Overview
5
3.3 Software Environment
It is suitable, but not only, for the following browsers: (mark the browser version in detail).
IE6+ browser
Firefox 14+ browser
Opera13+ browser
Chrome31+ browser
Safari5+ browser
The early operating system may not so good in compatibility.
WiseWay
Software User Manual 4First Use SNMP Card
6
4. First Use SNMP Card
4.1 First Login
After hardware connecting and setting of SNMP card and network, you can obtain the IP address of
SNMP card through WiseFind software. Open browser, enter the IP address of SNMP card (default IP
is 192.168.69.100), enter user name and password in login interface, then click OK to enter
monitoring page. Default user name of administrator is admin, corresponding password is admin.
Figure4-1 Login interface for SNMP card
After login the monitoring interface of SNMP card, you can remote monitoring the UPS or set the
related information.
Please ensure that the setting IP address is in the same network segment with user ’s computer IP
address.
WiseWay
Software User Manual 4First Use SNMP Card
7
The login interface is different in different browser, the manual take IE as an example.
4.2 Account Number Setting
User can modify the account, add new user and set user authority, etc. through setting and control ->
network setting-> webpage remote login according to needs.
Figure4-2 Remote login page
Details please see 5.3.5 Network Setting.
For system safety, please modify the default password of admin.
Please save the password of admin properly, if lost unfortunately, please contact the supplier.
If set the authority to no authority, the user will not login, please set carefully.
WiseWay
Software User Manual 5Use Guide
8
5. Use Guide
After login the webpage of SNMP card, it will show the current login user name and permission,
system function menu, system information and status, etc.
System menu includes basic information of main page, UPS information and status, setting and
control, log query, other functions. Details for each function are as follows.
5.1 Main Page Information
Main page shows the main information of monitored UPS, which makes the administrator understand
the real time status of the UPS conveniently.
5.1.1 Real Time Status of UPS
Figure5-1 UPS real time status
WiseWay
Software User Manual 5Use Guide
9
Item Description
Input voltage Shows the real time input voltage of the UPS
Output voltage Shows the real time output voltage of the UPS
Bypass voltage Shows the real time bypass voltage of the UPS
Battery status Shows the real time battery status of the UPS
Battery voltage Shows the real time battery voltage of the UPS
5.1.2 UPS Current Running Data
Figure5-2 UPS current running data
It shows the current running data of the UPS (note: the non-uploading data are all display as N/A, the
following tables are the same).
WiseWay
Software User Manual 5Use Guide
10
Item Description
Input voltage Shows the UPS real time input voltage
Input frequency Shows the UPS real time input frequency
Output voltage Shows the UPS real time output voltage
Output frequency Shows the UPS real time output frequency
Output source Shows the current system power supply way
Output load Shows the UPS output load
Bypass voltage Shows the UPS real time bypass voltage
Bypass frequency Shows the UPS real time bypass frequency
Battery voltage Shows the UPS real time battery voltage
Battery current Shows the UPS real time battery current
Battery fault Shows that whether the UPS is in fault
Battery temperature Shows the UPS real time battery temperature
Battery discharge time Shows the UPS battery discharging time
Remaining time of battery Shows the batter remaining time of the UPS
Remaining capacity of battery Shows the battery remaining capacity of the UPS.
5.1.3 UPS Current Running Status
Figure5-3 UPS current running status
It shows the current running status of the UPS.
WiseWay
Software User Manual 5Use Guide
11
Item Description
UPS communication status Shows the UPS current communication status
Input abnormal Shows that if there is abnormal input
Input power pending Shows that if it is in input power pending
Output abnormal Shows that if the UPS output abnormally
Output overload Shows that if the UPS is overload
UPS output off Shows the UPS output status
On bypass mode Shows that if the UPS stay in bypass mode
Bypass abnormal Shows that if the bypass is abnormal
Battery abnormal Shows that if the UPS battery is abnormal
On battery mode Shows that if the UPS stay in battery mode
Battery low voltage Shows that if the UPS is low voltage
Battery use up Shows that if the UPS battery is used up.
Temperature abnormal Shows that if the battery temperature is abnormal
5.2 UPS Information and Status
It provides basic information and running status of the UPS, including: system information and status,
UPS basic information, UPS real time data, UPS real time status, module real time status, chart
display.
5.2.1 System Information and Status
It provides the SNMP car information, UPS system information, network status, etc.
Information of SNMP card
Figure5-4 System information
WiseWay
Software User Manual 5Use Guide
12
Item Description
System name System name of SNMP card. It can be set according to “setting and
control->system setting”
System administrator System administrator of SNMP card. It can be set according to “setting
and control->system setting”
System location System location of SNMP card. It can be set according to “setting and
control->system setting”.
Total running time Total running time of SNMP card. It times as soon as powering on.
Hardware version Hardwire version information of SNMP card.
Firmware version
Firmware version of SNMP card.
S/N S/N of SNMP card.
Information of UPS system
Figure5-5 UPS system
Item Description
UPS last selftest time Shows the last selftest time.
UPS next selftest time Shows the next selftest time.
Email daily report time Shows the daily email report time.
Time of send alarm
information before shutdown
Shows the time of sending alarm information before shutdown.
Network status
Figure5-6 Network status
WiseWay
Software User Manual 5Use Guide
13
Item Description
MAC address Shows the MAC address of SNMP card.
Connection type Shows the connection type of SNMP card.
SNMP_IP address Shows the IP address of SNMP card.
Subnet mask Shows the subnet mask of SNMP card.
Gateway IP address Shows the gateway IP address of SNMPR card.
Primary DNS server
Secondary DNS server Shows the secondary DNS server address.
Time sever Shows the time server of SNMP card.
Email server Shows the address of email server
Login IP address Shows the login IP address of current user.
5.2.2 UPS Basic Information
It provides the UPS basic information and rated information.
Basic information
Figure5-7 UPS basic information
Item Description
Manufacturer Shows the UPS manufacturer
Firmware version Shows the UPS firmware version
Model Shows the UPS model
WiseWay
Software User Manual 5Use Guide
14
Rating information
Figure5-8 Rating information
Item Description
Rated input voltage Show the UPS rated input voltage
Rated input frequency Show the UPS rated input frequency
Rated output voltage Show the UPS rated output voltage
Rated output frequency Show the UPS rated output frequency
Rated apparent power Show the UPS rated capacity
Rated active power Show the UPS rated power
5.2.3 UPS Real-time Data
It provides the real-time data of the UPS. The data are obtained real time by system. It is made up of
UPS information, input information, output information, bypass information, battery information.
Figure5-9 Real-time data
WiseWay
Software User Manual 5Use Guide
15
It shows whole UPS real-time data information (the items, which out of the communication protocol,
will show as N/A)
UPS information
UPS communication status: shows the UPS real-time communication status.
Input information
Item Description
Input voltage Shows the real-time input voltage of UPS.
Input current Shows the real-time input current of UPS.
Input frequency Shows the real-time input frequency of UPS.
Input true power Shows the input true power of UPS.
Output information
Item Description
Output source Shows the power supply method.
Output voltage Shows the real-time output voltage of UPS
Output current Shows the real-time output current of UPS.
Output frequency Shows the real-time output frequency of UPS.
Output load Shows the real-time output load of UPS.
Output true power Shows the output active power of UPS.
Bypass information
Item Description
Bypass voltage Shows the real-time bypass voltage of UPS.
Bypass current Shows the real-time bypass current of UPS.
Bypass frequency Shows the real-time bypass frequency of UPS.
Battery true power Shows the real-time bypass active power.
WiseWay
Software User Manual 5Use Guide
16
Battery information
Item Description
Battery status Shows if the UPS fault is fault.
Battery voltage Shows the real-time battery voltage of UPS.
Battery current Shows the real-time battery current of UPS.
Battery temperature Shows the real-time battery temperature of UPS.
Battery discharge time Shows the battery discharge time of UPS.
Remaining time of battery Shows the remaining time of battery.
Remaining capacity of battery Shows the remaining capacity of battery.
5.2.4 UPS Real-time Status
It provides the real-time status of the UPS. The data are obtained real time by system, it is made up of
system information, input information, output information, bypass information, battery information.
Figure5-10 UPS real-time status
It shows the UPS real-time status (the items, which out of the communication protocol, will show as
N/A).
WiseWay
Software User Manual 5Use Guide
17
System information
Item Description
UPS communication status Shows the real-time communication status of UPS.
Remote shutdown UPS output Chooses whether to enable the remote shutdown UPS output.
Remote shutdown UPS Chooses whether to enable the remote shutdown UPS.
UPS system off Shows whether the system is off.
Charger abnormal Shows whether the battery charge is abnormal.
Fan abnormal Shows whether the UPS fan is abnormal.
Fuse abnormal Shows whether the UPS fuse is abnormal.
Other faults Shows whether the UPS is fault.
Shutdown pending Shows whether to enable the UPS shutdown pending.
Immediate shutdown Shows that the UPS will shut down immediately.
Testing Shows whether the UPS is testing.
Diagnostic test fail Shows the diagnostic test status.
Input information
Item Description
Input abnormal Shows whether the input of UPS is abnormal.
Input power pending Shows whether the UPS stay in input power pending status.
Output information
Item Description
Output abnormal Shows whether there exit output abnormal of UPS.
Output overload Shows whether the UPS is overload.
UPS output off Shows whether the output of UPS is closed.
WiseWay
Software User Manual 5Use Guide
18
Bypass information
Item Description
On bypass mode Shows whether the UPS is on bypass mode.
Bypass abnormal Shows whether the bypass is abnormal
Battery information
Item Description
On battery mode Shows whether the UPS is on battery mode.
Battery abnormal Shows whether the UPS battery is abnormal.
Battery low voltage Shows whether the UPS is low voltage.
Battery use up Shows whether the UPS battery is used up.
Temperature abnormal Shows whether the UPS temperature is abnormal.
5.2.5 Module Real-time Status
It provides the real-time status of message and temperature & humidity module. It is made up of
Modem real-time status and 485 module real-time status.
Modem real-time status
It includes local Modem mode and remote server mode.
Figure5-11 Modem real-time status (local Modem mode)
Item Description
Communication status Shows the communication status of Modem.
Signal quality Shows the communication signal quality of Modem.
WiseWay
Software User Manual 5Use Guide
19
Modem manufacturer Shows the manufacturer of Modem.
Module model Shows the model of Modem.
Software version Shows the software version of Modem
operator
SMS service centre number Shows the SMS service centre number of operator.
Figure5-12 Modem real-time status (remote server mode)
Item Description
Server IP address Shows the SMS server IP address.
Port number Shows the port number of SMS server.
Connection status
Communication status Shows the communication status of Modem.
Signal quality
Modem manufacturer Shows the manufacturer of Modem.
Module mode Shows the mode of Modem
Software version Shows the software version of Modem.
operator
SMS service centre number Shows the SMS service centre number of operator.
485 module real-time status
This function is only available for mode KC501S, not applicable for KC502S.
WiseWay
Software User Manual 5Use Guide
20
Figure5-13 485 module real-time status
Item Description
THS module (1~4) Shows the temperature & humidity module information, it supports at
most 4 temperature & humidity modules
Communication status Shows the communication status of SNMP card and temperature &
humidity module.
Temperature Shows the real-time temperature of temperature & humidity module.
Humidity Shows the real-time humidity of temperature & humidity module.
5.2.6 Chart Display
It displays the main data of UPS by chart, which is easy to observe for administrator. It includes
battery capacity, battery temperature, output load and real-time voltage line chart.
Figure5-14 Chart display
WiseWay
Software User Manual 5Use Guide
21
Item Description
battery capacity Shows the battery capacity.
battery temperature Shows the battery temperature.
output load Shows the output load of UPS. If it is single-phase, it will show in
output load_R.
Real-time voltage line chart Shows the real-time voltage curve of UPS.For single-phase power, it
shows input voltage, output voltage, bypass voltage; for three-phase
power, it shows input voltage_R, input voltage_S, input voltage_T,
output voltage_R, output voltage_S, output voltage_T, bypass
voltage_R, bypass voltage_S, bypass voltage_T.
5.3 Setting and Control
It is used to set and control the SNMP card and UPS, including remote control, UPS parameters
setting, UPS ON/OFF setting, wake up LAN, network setting, SNMP setting, Email setting, SMS
setting, 485 bus module setting, system setting.
5.3.1 Remote Control
It includes UPS selftest and other items, which allow user to test the UPS by remote control. Click
the performing test items, click “Apply” icon to carry on the test.
UPS selftest
Figure5-15 UPS selftest
UPS selftest for 10 seconds: UPS performs the discharging test for 10 seconds.
UPS discharge test XX minutes: UPS performs the discharging test according to the setting time.
UPS test until low voltage: UPS performs the discharging test to low voltage.
Cancel UPS test: UPS cancel each performing selftest.
WiseWay
Software User Manual 5Use Guide
22
Only equipped with the selftest module, the UPS can carry out the selftest. At present, it supports the
UPS which use the AEC protocol only, for other models, please consult supplier.
Other items
Figure5-16 Other items
UPS shutdown: UPS turn into shutdown status.
the minutes UPS to standby: UPS enter standby status for the minutes you set.
UPS wake-up from standby state: the UPS switch to normal status from standby status.
Restart UPS: UPS perform shutdown then restart again.
Only equipped with the selftest module, the UPS can carry out the above function. At present, it
supports the UPS which use the AEC protocol only, for other models, please consult supplier.
5.3.2 UPS Parameters Setting
It includes the UPS parameter, battery parameter, UPS records, UPS selftest, alarm value and port
setting.
Figure5-17 UPS parameters
WiseWay
Software User Manual 5Use Guide
23
The detailed parameters setting of UPS differs from others because the protocols are different. The
manual take the AEC protocol as an example to introduce the setting. For other models, please
consult supplier.
Manufacturer: select the manufacturer of UPS.
UPS communication protocol: select corresponding UPS communication protocol.
Number of battery: set the battery number.
Group of battery: set the battery group number.
Enable battery management: select “Yes” to enable the battery management.
UPS rated power: enter UPS power.
Battery rated capacity: enter battery rated capacity
Date of battery installation: enter the battery replacement time.
Single battery full charge voltage: enter single battery full charge voltage.
Single battery end of discharge voltage: enter single battery end of discharge voltage.
When enable battery management, user needs to provide the above information for SNMP card to
calculate. But the calculated battery capacity and remaining discharging time may exist error for the
battery quantity is different and that may differ voltage difference, battery aging, measure error, etc.
the calculated data is for reference only. Please use these information with care.
WiseWay
Software User Manual 5Use Guide
24
UPS log
Figure5-19 UPS log
UPS data log (minute): set the record interval time of UPS log.
UPS selftest
Figure5-20 UPS selftest
UPS testing interval: set the interval time of test, if it set to “no test”, the following function will
close.
UPS testing time per week: set the date of test per week.
UPS selftest time: set the date of selftest per week.
UPS test type: set the test type of UPS.
Only equipped with the selftest module, the UPS can carry out the selftest function. At present, it
supports the UPS which use the AEC protocol only, for other models, please consult supplier.
Alarm setting
Figure5-21 Alarm setting
UPS failed to communicate over time: set the waiting time for communication break off when it
judges the UPS fail to communicate.
WiseWay
Software User Manual 5Use Guide
25
Port setting
Figure5-22 Port setting
UPS: the setting data should be in accord with that of UPS.
5.3.3 UPS ON/OFF
It is used to set the schedule for UPS startup and shutdown. After finishing setting, click “apply” to
make it tale effect.
Figure5-23 Weekly timing on/off set
Date: from Sunday to Saturday.
Start time: set the everyday starting time.
Off time: set the everyday shutdown time.
Figure5-24 Special day on/off setting
Date: set the special on/off date.
Start time: set the starting time of special day.
Off time: set the shutdown time of special day.
WiseWay
Software User Manual 5Use Guide
26
If you enable the special day on/off setting, the corresponding weekly timing on/off time of that day
will be invalid.
Figure5-25 Other setting
Shutdown UPS ahead of time to send alarm: set the shutdown alarm time in advance.
Shutdown after mains abnormal: set if shut down UPS after mains abnormal and waiting time before
shutdown.
Low battery voltage delay shutdown: set if shut down UPS after battery low and waiting time before
shutdown.
Shutdown after over-temperature: set if shut down UPS after over-temperature and waiting time
before shutdown.
Shutdown after overload: set if shut down UPS after overload and waiting time before shutdown.
Only equipped with the function, the UPS can carry out the above function. At present, it supports the
UPS which use the AEC protocol only, for other models, please consult supplier.
5.3.4 Wake on LAN
It is used to wake up the computer in LAN after mains normal. After setting, click “apply” to save the
setting.
WiseWay
Software User Manual 5Use Guide
27
Figure5-26 Wake on LAN
Remote port number: set the remote port number (range 1~65535), and the setting cannot conflict
with others.
MAC address (1~6): select the computer MAC address which needs to be woke up, click apply.
If using LAN wake up function, please ensure if the main board of woke up computer supports the
function and enable the setting “Wake up by LAN” or other similar items.
5.3.5 Network Setting
It provides network setting of SNMP card and account assign and authority setting. After setting,
click “apply” to save the setting.
Figure5-27 Connection status
Connection status
IP access method: if it is set to DHCP automatically set, the SNMP card will obtain data
automatically. If it is set to manual setting, it needs to set the following parameters.
IP address: set IP address.
Subnet mask: set subnet mask.
Gateway address: set gateway address.
WiseWay
Software User Manual 5Use Guide
28
If the IP address is reset, please use the setting IP address to login.
DNS server IP address
If the IP access method is DHCP automatically set, the SNMP card will obtain data automatically. If
it is set to manual setting, you should set the following parameters manually.
Primary DNS server IP address:
Set the primary DNS server IP address.
Secondary DNS server IP address:
Set the secondary DNS server IP address.
If the server prohibits setting the IP address or there is no DHCP server, it will not obtain IP
automatically. While using the function, please confirm the network environment.
Remote login
Figure5-28 Remote login page
It sets the administrator’s account and distributes the authority.
User name: distributes the user name of SNMP card.
Password: sets the user password.
Permissions: sets the user’s authority. If it is set to no authority, user will lose the login authority.
WiseWay
Software User Manual 5Use Guide
29
IP address management: if is set to *.*.*.*, administrator can login and visit SNMP card in the IP
address of current network segment; if it is set to specific IP, user can login in the specific IP address
only.
If all users are deleted, user will not login the SNMP card. If cannot login SNMP card by
misoperation, please contact supplier.
If the permissions of all users are set to no authority, user will not login SNMP card, please set the
permission with care. If cannot login SNMP card by misoperation, please contact supplier.
5.3.6 SNMP Configuration
The data in this page are used to connect with the software of SNMP webmaster. The setting
parameters in this page are used to connect with SNMP webmaster and match with WiseClose,
WiseFind in the CD of SNMP card. After setting, click “apply” to save the setting.
Figure5-29 SNMP configuration
SNMP Configuration
Community: set the community name, and the name should be as the same as that of upper computer,
or, it will not communicate properly.
SNMP port: set the SNMP port.
Trap receiving port: set the trap receiving port.
WiseWay
Software User Manual 5Use Guide
30
Trap sending type: set the trap sending type according pull-down list, at present, it only supports
RFC1628 protocol.
Trap notice
IP address of the recipient: set the IP address of upper computer recipient.
Community: set the name of community, and the setting should be as the same as that of upper
computer, or it will not communicate properly.
Engine ID: set the Engine ID and the setting should be as the same as that of upper computer, or it
will not communicate properly.
Receive: it will take effect after checked.
Permission setting
Figure5-30 Permission setting
Authorized IP address: set the authorized IP address.
Community: set the name of community, and the setting should be as the same as that of upper
computer, or it will not communicate properly.
Permission: set the permission of visited IP.
V3 user configuration
Figure5-31 V3 user configuration
WiseWay
Software User Manual 5Use Guide
31
There has 3 safety level, they are no Auth No Rriv, auth No Rriv, authRriv.
No Auth No Rriv: Authentication method is that the confirm password and encrypted password is
empty.
AuthNoRriv: Authentication method is that the confirm password is not empty and encrypted
password is empty.
AuthRriv: Authentication method is that the confirm password and encrypted password is not empty.
User name: set the user name of SNMPV3
Authentication method: set the authentication method, and it can be set to MD5 and SHA.
Confirm password: set the confirm password, and the password should be no less than 8 characters.
Encryption method: set the encryption method, and it can be set to DES and AES128.
Encrypted password: set the encrypted password, and the password should be no less than 8
characters.
Permission: set the authority of V3 user.
When using the SNMP configuration module, if user is non-professional person, please read the
manual carefully or consult professional person. Once set the module improperly, the module will not
be used. If any question, please consult the supplier.
Context setting
Figure5-32 Context setting
The function is used to obtain the data of other SNMP card.
Context: set the context to communicate with upper computer.
WiseWay
Software User Manual 5Use Guide
32
SNMP version: select SNMP version.
Community: set the communication community.
IP address: set the IP address of SNMP card.
5.3.7 Email Setting
The page is mainly used to send the data or events, detected by SNMP card, to the Email of
administrator immediately. After setting, click “apply” to save the setting.
Email server: set the server address of sent Email.
Email port: set the SMTP port of sent Email. (note: SMTP port should be in accord with the Email
server).
Email address sender: set the sending Email address.
Email transmission is encrypted using SSL: set whether use SSL encrypted to transfer message email
(note: it needs that the Email server supports SSL encrypted.).
Use password authentication: set if the Email server needs password authentication (note: it needs
that the email server supports account and password to login).
Email account: when the email server needs account checking, enter the email account.
Email password: when the email server needs account checking, enter the email password.
Before use, please confirm that the email of sender enable SMTP service, which is to avoid the email
alarm function cannot be used properly.
WiseWay
Software User Manual 5Use Guide
33
Email address of recipient (receiving the event log available)
Email sent when the event occurs warning: when set to “Yes”, the function is available.
Account (1~8): this row is used to enter the sender email.
Event set: click it to enter event setting.
Figure5-35 Event setting
Select the receiving events, click “apply” to save the setting. Click “back” to return email setting
page.
Figure5-36 Email address of recipient (receiving daily report available)
Daily reports sent on time: set to “yes” to enable the function. And set the sending time in date box.
WiseWay
Software User Manual 5Use Guide
34
Account (1~4): set the email of recipients.
Test set
Figure5-37 Test set
Test e-mail recipient: enter the testing email of receiving email, click “send email” to test the setting.
The language of receiving mailbox should be in accord with that of SNMP card. If inconformity, it
may cause the sending email messy code.
5.3.8 SMS Setting
The page is mainly used to send the data or events, detected by SNMP card to the administrator by
phone massage . After setting, click “apply” to save the setting.
SMS setting
Connection mode: it can be set to remote server or local server.
Remote server
Figure5-38 SMS setting (remote server)
SMS server IP: set the IP address of message sending server.
Server port: set the port of message sending server.
Use password authentication: select whether to use password authentication
Server user name: set the server account of message sending server.
Server password: set the corresponding account password of message sending server.
Local modem
WiseWay
Software User Manual 5Use Guide
35
Figure5-39 SMS setting (local modem)
Model port: the setting data should be in accord with connected UPS.
Phone number to receive event notifications
Figure5-40 Phone number to receive event notifications
When the event occurs to send short message alarm: set to “yes” to enable the function.
Phone number(1~8):set the administrator ’s phone number.
Event set: click “event set” to enter event setting page, select the received events and click “apply” to
confirm the setting. Click “back” to return SMS setting page.
Figure5-41 Event setting page
WiseWay
Software User Manual 5Use Guide
36
UPS control: you can select enable UPS control and disable UPS control in pull-down list. If
selecting enable UPS control, you can send remote control command to UPS by phone, detailed
commands are as follows:
S1: selftest for 10S
S2+NN: UPS discharge test for N min
S3: UPS discharge to low-voltage
S4: cancel UPS test
S5: shut down UPS power
S6+NNNN: let the UPS keep sleepy for XXXX minutes
S7:wake up the UPS from sleepy
S8: restart UPS
Running remote control function needs the UPS equipped with the function module. At present, it
supports the UPS which use AEC protocol only, for other model, please consult supplier.
Figure5-42 Test set
Test message recipient mobile phone No.: enter the test phone number in the box, click “send SMS”
to start the test.
The signal quality of sent message is related to the network environment of message module and the
operator. Please ensure that the operator and network environment is normal, which is to ensure the
module function can work normally.
WiseWay
Software User Manual 5Use Guide
37
5.3.9 485 Bus Module Setting
It is mainly used to set the communication with temperature & humidity module, at the same time,
set each temperature & humidity module. After setting, click “apply” to save the setting.
RS485
Set the port according to temperature & humidity module.
Figure5-43 Bus module setting
Module: temperature & humidity module.
Module type: select corresponding module type according to temperature & humidity module.
Device address: set the temperature & humidity module address.
Upper limit of temperature/ lower limit of temperature: set the max. and min. temperature, if setting
exceeds the range, it will send alarm.
Upper limit of humidity/ lower limit of humidity: set the max. and min. temperature, if setting
exceeds the range, it will send alarm.
5.3.10 System Setting
The page is to set the basic information of system. After setting, click “apply” to save the setting.
Figure5-44 System configuration
System name: set the system name.
System administrator: set the administrator of the system.
System location: set the system location.
WiseWay
Software User Manual 5Use Guide
38
Above settings can be Chinese, Chinese traditional, English. Due to the problem of operating system
and browser language environment, the display may exit messy code. It is suggested that using
English as the international common language.
Figure5-45 Internet time
Auto update interval: set the interval time of auto update.
Time server: after checked web, it can choose corresponding different internet time; if choose custom,
user can adjust the time according to time server.
Figure5-46 Time and date
System time: set the system time of SNMP card, click “adjust the system time” to make it take effect.
Time zone: set the time zone of SNMP card, click “change the time zone” to make it take effect.
Regulate time by DST: select whether use the DST.
Figure5-47 Language setting
Interface language: set the interface language. At present, there are 3 options: Chinese, Chinese
traditional, English.
Email and SMS language: At present, there are 3 options: Chinese, Chinese traditional, English.
5.4 Log Query
It provides the query for event log, SMS log and UPS data.
WiseWay
Software User Manual 5Use Guide
39
5.4.1 Event Log
The page can look up and export happened event logs.
Figure5-48 Event log
Query date: click it to select the query date.
Export: export the event log of current month by Excel.
Clean: clear event log, you can select the clear date in pull-down list.
Once the event log is cleared, the data will not restore, please use the function with care.
5.4.2 SMS Log
The page can look up and export the SMS logs.
Figure5-49 SMS log
WiseWay
Software User Manual 5Use Guide
40
Query date: click it to select the query date.
Export: export the event log of current month by Excel.
Clean: clear event log, you can select the clear date in pull-down list.
Once the SMS log is cleared, the data will not restore, please use the function with care.
5.4.3 UPS Data
The page can look up and export the UPS data logs.
Figure5-50 UPS data log
Query date: click it to select the query date.
Export: export the UPS data log of that day by Excel.
Clean: clear UPS data log, you can select the clear date in pull-down list.
WiseWay
Software User Manual 5Use Guide
41
Once the UPS data log is cleared, the data will not restore, please use the function with care.
5.5 Other Functions
The module provides the function of firmware update, port debug and product manufacturer
information.
5.5.1 Firmware Update
The page displays the firmware version and update method of the firmware.
Figure5-51 Firmware update
Version
Firmware version: show the version information of current firmware.
WiseWay
Software User Manual 5Use Guide
42
Location update
Update file: select the folder of location update, click “update” to start the update.
FTP update
FTP server: set the FTP server address for saving the update file.
User name: user name of FTP server.
Password: password of FTP server.
Time of automatic update: set the auto update time. If you choose the “weekly”, program will be updated every seven days.
Manual update: click “update” to start to update.
If there needs to use the function of FTP network update, the user network environment must support the FTP server transmission.
If there needs to use FTP server to update, it is necessary to put the update files to the root directory of FTP server.
WiseWay
Software User Manual 5Use Guide
43
If user’s network does not support the FTP server transmission, please use location update.
5.5.2 Port Debug
It provides port information display and export function.
Figure5-52 Port debug
Play mode: it can be set to close, manually and auto mode.
Coding type: it includes ASCII code, hexadecimal.
Port type: it includes: UPS, Modem, RS485, and System.
Export debug data: click the button to export the debug data by compressed files.
5.6 About
The page includes firmware information of SNMP card and manufacturer information.
Figure5-53 About