Scheme Design Report - EMA - WKCDA
-
Upload
khangminh22 -
Category
Documents
-
view
0 -
download
0
Transcript of Scheme Design Report - EMA - WKCDA
M+ CONSULTANCY JV SUBMISSION OF TREE AND TURF GRASS PLANTING AND LANDSCAPE PLANS (REV E)
30062020
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
Project
Museum for Visual Culture in West Kowloon Cultural District
Client Consultant
WKCDA
M+ Consultancy JV (MJV)
Element Other
3AXXX-TFP-LAN-REP-0001-LMP-WS2-XE Submission of Tree and Turf Grass Planting and Landscape Plans
Discipline
LAN
E 30 JUN 2020 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
D 22 MAR 2020 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
C 29 JUL 2015 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
B 11 Nov 2014 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
A 23 Jun 2014 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans For review
Rev Date Prepared by Checked by Approved by Endorsed by Description Status
Internal Review and Approval Table
F 30 JUN 2020 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
E 15 MAR 2020 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
D 29 JUL 2015 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
C 13 JUL 2015 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
B 11 Nov 2014 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
A 23 Jun 2014 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
Rev Date Prepared by Checked by Approved by Endorsed by Description Status
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
CHECKING ROUTING SHEET
CLIENT West Kowloon Cultural District Authority
PROJECT TITLE Consultancy Services for M+ Museum for Visual Culture in West Kowloon Cultural District
DOCUMENT TITLE Tree and Turf Grass Planting and Landscape Plan
(Rev E)
PREPARED BY NAME Stanley Sze
(ISA Certified Arbotist HK-0034A)
SIGNED DATE 30 June 2020
CHECKED BY NAME Lam Tak Wah (RLA 070)
SIGNED DATE 30 June 2020
1
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
Table of Content 1 OBJECTIVE AND PURPOSE OF THE REPORT 2 INTRODUCTION 3 LANDSCAPE TREE AND PLANTING PLAN 4 POST PLANTING CARE PLAN
Appendix A PLANTING PLANS AND SCHEDULE B NOT USED C GREEN COVERAGE PLANS D POST-PLANTING CARE PLAN
F SUPPLEMENTARY INFORMATION G IMPLEMENTATION PROGRAMME
H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
1 OBJECTIVE AND PURPOSE OF THE REPORT
111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approval under Section 8(3) of the EIA Ordinance (Appendix H) This report is only prepared for the M+ Museum because the Tree and Turf Grass Planting and Landscape Plan will be developed in phases as such there will not be an entire plan serving for the WKCD
112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on 04 August 2015
113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
2 INTRODUCTION
211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital part of any world-class cityrsquos economic and social fabric The West Kowloon Cultural District Authority (WKCDA) was established under the West Kowloon Cultural District Authority Ordinance (WKCDA Ordinance) Cap 601 to develop the WKCD (named ldquothe Siterdquo hereafter) The WKCD include
i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and as exhibition centre) other arts and cultural facilities (OACF) Retail Dining and Entertainment (RDE) facilities transport facilities and 23 ha public open space (which collectively constitute the ldquoCapital Projectsrdquo)
ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
iii) Major repair and renovation of the facilities and iv) Collection exhibition development conservation
laboratory equipment and library setup for the M+
212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
3 LANDSCAPE TREE AND PLANTING PLAN
31 Ground Floor and B1 Floor 311 Along the northern perimeter inter-planting of diverse trees forms a
thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent on the structural elements below grade Trees have been selected for their structural characteristics Eucalyptus tereticornis forms the upper canopy It is traditionally planted to form barriers and grows tall and straight very quickly It has fragrant leaves and flowers and lovely peeling bark The lower canopy consists of the native trees Sterculia lanceolata and Viburnum odoratissimum These species have an expressive and organic habit and will grow out and away from the Eucalyptus flank The understory is composed of Polyspora axillaris and Ligustrum sinense These are flowering small trees or large shrub with a light canopy and wide branching habit The species provides immediate screening at planting and bears a profusion of white flowers in spring and winter (refer to Table C and D) For the planting plan and planting schedule please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A accordingly
312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenable to the changing light conditions that will occur as the trees in front of the fenceline grow in (refer to Table E) For the planting plan and planting schedule please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A accordingly
313 Not used
314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely define zones
for congregation along the promenade Terminalia mantaly could reach to a potential height of 10-15 m and is distinguished by its erect stem and conspicuously layered branches It has smooth leaves with wavy margins that are bright green in youth held in terminal rosettes (refer to Table B) For the planting plan and planting schedule please refer to Drawing No 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 and 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 in Appendix A accordingly
315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appearance of a new planting In the same vein trees are to be planted at slightly irregular intervals and not on a straight line again to simulate more mature environmental habits of the species
316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high buildings they should a have a strong visual and spatial impact from the day of planting
317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively (refer to Table A)
318 Hydroseed turf grass is proposed at pedestrian zone of B1 floor and Ground floor covering approximately 1287 m2 which is 143 of the total greenery area The details of the percentage of grass coverage refer to Appendix C Further to the approval condition of EIAR-1782013 it is confirmed that Carpet Grass of the Axonopus genus including Axonopus compressus will not be planted within M+ Boundary for compliance Hydroseed species to refer to Appendix A accordingly
319 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B - Table F )
32 3 Floor Podium Roof 321 On the roof slabs of concrete are divided by long joints Built into the
strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a range of scaled gathering spaces Twelve related plant palettes composed largely of subtropical monocots have been selected for foliage suitability and form The selected species are marked by their subtle gradations and
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
modulations of colour as well as the formal architecture of their leaves and flowers These species are arranged into vegetative clans led by a majority species and supported by a set of supporting species Dense mass-planting of a restrained planting palette in wide swaths will generate a subtle graphic field condition legible from upper stories of the building as well as on the roof itself
322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cadence of vegetation that modulates in section as well as plan while still preserving sight lines across and over the flora towards the Hong Kong skyline and beyond This overall height scheme is altered in specific locations to provide for moments of greater insularity or exposure
323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles of the individual plants are to be left visible seedpods dried blooms etc are to be left on the plants nuancing the formal qualities of the scheme throughout the year
324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-LAN-DWG-0524-P00-L003-WS4 and 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4 in the Appendix A
325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
1 The site area of this project is approx 22966 m2 The green coverage is 9002774m2 22966m2 which is approximately 39
Table A ndash Greening Coverage Summary Table
Location Green Coverage (m2) Remarks
Green area at pedestrian zone
B1 Floor 297940 (GP3) Refer to Appendix C
Ground Floor 989065 (GP1 + GP2) Refer to Appendix C
Vertical Greenery at pedestrian zone
Green Area at Pedestrian zone
500556 (VP1 + VP2) Refer to Appendix C
Green area at 3 Floor Terrace Zone
3 Floor podium roof 7215213 (GT1-GT18) Refer to Appendix C
Total Greenery Area 9002774
Total Greenery Area Percentage
~ 391 Comply with the Master Register greenery
requirement 2
2 Based on the Approved West Kowloon Cultural District Development Plan No SK20WKCD2 there is a requirement for the provision of minimum green coverage of 30 and 60 for the whole WKCD and the Park respecvely
Table B- Tree Planng Schedule for B1 Floor
SCIENTIFIC NAME HEIGHT
(MM)
SPREAD (MM) DBH (MM) QTY
Terminalia mantaly 5000 3000 100 3 please refer to Drawing No 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 and 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 in Appendix A These 3 trees planng is planted at a planter interfacing with promenade planter and is subject to the planng design co-ordinaon with Promenade design
Table C- Tree Planng Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM)
SPREAD (MM)
DBH (MM) QTY
Eucalyptus tereticornis 5000 3000 75 4
Eucalyptus tereticornis 7000 4000 100 3
Sterculia lanceolata 4000 3000 100 4
Viburnum odoratissimum 3000 2000 75 2
nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
Table D- Large Shrub Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM) SPREAD (MM) QTY
Polyspora axillaris 2000 1000 17 Ligustrum sinense 2000 1000 18
nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
Table E- Climber Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM) SPACING (MM)
Campsis grandiflora 600 200 Ficus pumila 600 200 Epipremnum aureum 600 200 Lonicera japonica 600 200 Tristellateia australasiae 600 200 nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
Table F- Hydroseeding Seed Mix for Ground Floor SCIENTIFIC NAME RATE
Imperata cylindrica Varmajor 20 GSQM
Celosia argentea 5 GSQM Kalimeris indica 5 GSQM native species
4 POST PLANTING CARE PLAN
411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX A PLANTING PLANS AND SCHEDULE noitpircseD -on gniwarD
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 1 of 2) 3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 2 of 2) 3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 1 of 4) 3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 2 of 4) 3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 3 of 4) 3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 4 of 4) 3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 3F Shrubs and Groundcovers Schedule 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 1 of 2) 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 2 of 2)
1
7
6
5
4
A B C D E F
SPACE ALL TREESAT LEAST 5mFROM BASE OF WALL
AHU AHU
+1270+1260
250mm SURFACE CHANNEL
CLIMBER PLANTINGON CSF FACADE
1100 (H)BALUSTRADE
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
LOJ
TRA
(ALT
ERNA
TE P
LANT
ING)
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
FUEL PIPERUNNING IN SOILMATCH LINE
REFER to INSERT A
MIN 2000
MIN 2000
GF - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Et(l) EUCALYPTUS TERETICORNIS 細葉桉 5000 3000 75 4
Et(h) EUCALYPTUS TERETICORNIS 細葉桉 7000 4000 100 3
Sla STERCULIA LANCEOLATA 假蘋婆 4000 3000 100 4
Pax POLYSPORA AXILLARIS 大頭茶 2000 1000 - 17 MULTI-TRUNK
Lsi LIGUSTRUM SINENSE 山指甲 2000 1000 75 18
Vod VIBURNUM ODORATISSIMUM 珊瑚樹 3000 2000 75 2
GF CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 60000 - 20000 1200 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 60000 - 20000 1800 4 SHOOTS PER PLANT
EPA EPIPREMNUM AUREUM 綠蘿 60000 - 20000 400 4 SHOOTS PER PLANT
LOJ LONICERA JAPONICA 忍冬 金銀花 60000 - 20000 72 4 SHOOTS PER PLANT
TRA TRISTELLATEIA AUSTRALASIAE 三星果 60000 - 20000 72 4 SHOOTS PER PLANT
CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED AS STATED
HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
Native Species
2
1
7
6
A
AT LEAST 5mFROM BASE OF WALL
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
PLANTING AREA TO BEDESIGNED BY THE PARK
PLANTING AREA TO BEDESIGNED BY THE PARK
MATCH LINE
REFER to INSERT A
MIN 2000
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBERALONG WALL
TREE
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-G
AM-L
AN-D
WG
-900
3-P0
0-L0
00-W
S4
CAG
FIP
(ALTERNATE PLANTING)
SEDTRANSFER
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED SELF-CLINGING CLIMBER
PLANTING ON VERTICALBOUNDARY WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
EPA
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P 72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
retaW tlaS gnitsixEPumping Station
KRAP05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBBox
15P
A05P kraP gnicafretnI +M
N
04PM+
A93PB93P
FSCEDR
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 2)
3AXXX-GAM-LAN-DWG-9002-P01-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
1 100 SCALE BAR
0 25 5m
N KEY PLAN
MAIN PLAN
INSERT A
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
031
220
19 9
40
40 A
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
1
7
6
5
4
3
2
G H J K L M
CAG
FIP
(ALTERNATE PLANTING)
SELF-CLINGING CLIMBER
PLANTING ON VERTICAL
BOUNDARY WALL
ARTIST
SQUARE
CSF
STAFF
ENTRANCE
ST
PR
LT-51
LT-53
LT-52
ART
LIFT
ST
PR
MEP
UP
UP
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
STREET FIRE HYDRANT
P39B BOUNDARY
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
EPA
P39B BOUNDARY
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-G
AM
-L
AN
-D
WG
-9
00
2-P
00
-L
00
0-W
S4
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBER
ALONG WALL
PROPRIETARY WIRE
GREEN WALL SYSTEM
TREE
P39B HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
P39B CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 600 - 200 700 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 600 - 200 630 4 SHOOTS PER PLANT
ALL CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED
Native Species
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFSFIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Medium
Theatre I
Medium
Theatre IICCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega Perfo
rmance V
enue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREES
AND SHRUBS PLAN
(SHEET 2 of 2)
3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01
11102019 101916 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
1
2
3
4
5
6
7
7
HR
FS3-1-005B
PA250 NOS
CAP750 NOS
AW700 NOS
CAS650 NOS
HP250 NOS
IC350 NOS
HS50 NOS
IC350 NOS
AZ250 NOS
HS350 NOS
SR490 NOS
HP150 NOS
HP950 NOS
HP250 NOS
SR300 NOS
CAS200 NOS
CA515 NOS
JG350
HS250 NOS
HP450 NOS
HS350 NOS
CAS450 NOS
JG150 NOS
AW200 NOS
CAP700 NOS
SR600 NOS
AZ350 NOS PA
650 NOS
JG1250 NOS
CAS350 NOS
CA450 NOS
SR500 NOS
DFL150 NOS
ABO150 NOS
HP450 NOS
HS400 NOS
HS150 NOS
SR250 NOS
HP400 NOS
AZ50 NOS
AZ350 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
AZ750 NOS
CAP500 NOS
CA150 NOS
FFS30 NOS
AZ200 NOS
HP300 NOS
CAP400 NOS
DFL100 NOS
500500
500
500
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 4)
3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
900mm (H) HS SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
1100mm (H) HP SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
^
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
31
04 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
2
3
4
5
6
7
HR
FS3-1-005A
FS3-1-005BHR
ST-76
HP400 NOS
AZ50 NOS
CAS700 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
CAP500 NOS
AW350 NOS
HP300 NOS
SR550 NOS
HS650 NOS
DFL150 NOS CAP
350 NOS DFL220 NOS
SR250 NOS
AZ250 NOS
SR520 NOS
HP350 NOS SR
340 NOS
AZ600 NOS JG
450 NOS HS250 NOS
ABG100 NOS
AZ250 NOS
SR650 NOS
JG900 NOS
PA200 NOS
HP250 NOS
AW850 NOS
CAS850 NOS
CAP800 NOS
CAS850 NOS
SR350 NOS
PA500 NOS
HP300 NOS
500
500
0
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
5398
5085
5258
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 2 of 4)
3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
29
41 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
B C E FDA
HR
11
FS3-1-005B
CFA180 NOS
CFC250 NOS
CFC150 NOS
CFB450 NOS
CFA250 NOS
JG150 NOS
DE350 NOS
OJ3050 NOS
DE350 NOS
ZCI2100 NOS
CAS400 NOS
CGY50 NOS
CGY250 NOS
CFC250 NOS
CFA550 NOS
TS60 NOS
CGY250 NOS
CFT150 NOS
ABO80 NOS
CFT80 NOS
ABO60 NOS
JG150 NOS
CFC100 NOS
CFA150 NOS
CGY250 NOS
CFA250 NOS
CFT500 NOS
CFA300 NOS
YGC150 NOS
CAS150 NOS
CT200 NOS
TS50 NOS
CFC150 NOS
CGY350 NOS
CFB350 NOS
ZCA2000 NOS
DE550 NOS
ZCI1450 NOS
DE100 NOS
ZCA1200 NOS ZCI
4400 NOS
DE550 NOS
ZCI4250 NOS
JG150 NOS
CFC50 NOS
CGY500 NOS
CFB200 NOS
CFA450 NOS
BC200 NOS
CFA392 NOS
FFS25 NOS
CGY600 NOS
CAS250 NOS
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
BC350 NOS
CFC800 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
ZCI3550 NOSOJ
250 NOSZCI
1350 NOSDE
450 NOS
ZCA2250 NOS
NCA150 NOS
150 NOS
CGY450 NOS
CFB50 NOS
CFA300 NOS
CAS200 NOSCGY
250 NOSCFA520 NOS
FFS60 NOS
BC100 NOS
CTSON 051
500
500
500
500
500
500
500
500
CAS120 NOS
TOP VENT OPENING
900 x 900ACCESSHATCH
900 x 900ACCESSHATCH
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
NOTES
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 3 of 4)
3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
^
^
^
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
35
44 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
HR
11
FS3-1-005A
FS3-1-005BHR
ST-76
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
NCA150 NOS
CFA100 NOS
CVI150 NOS
CFT350 NOS
JG150 NOS ZCI
2000 NOS
NCA60 NOS
ZCA2300 NOS
CFC150 NOS
JG100 NOS
ZCA1250 NOS
ZCI2500 NOS
NCA250 NOS
ZCA400 NOS
CFT400 NOS
ZCI600 NOS
CT250 NOS
CFC650 NOS JG
110 NOS
CFC50 NOS
OJ1350 NOS
CFB160 NOS
CFA500 NOS
DE750 NOS
ZCA5050 NOS
OJ2650 NOS
ZCI3750 NOS
ZCA3850 NOS
CFT1150 NOS
CT450 NOS
CT250 NOSCAS
800 NOSJG250 NOS
CT950 NOS
CAS100 NOS
CGY350 NOS
CT350 NOS
CAS500 NOS
CFT200 NOS
CT150 NOS
OGY100 NOS
CFA550 NOS
CFC200 NOS
CVI150 NOS
FFS100 NOS
CFB150 NOS
JG200 NOS
ABG250 NOS
CFC750 NOS
CFA450 NOS
CFC300 NOS
CVI150 NOS
CFB100 NOS
TSC100 NOS
ZCA2000 NOS
CGY300 NOS
CFT1200 NOS
BC250 NOS
JG100 NOS
CFC60 NOS
CVI50 NOS
CFB100 NOS
CVI50 NOSCGY
100 NOS
CAS250 NOS
CGY300 NOS
CFA1000 NOS
CAS900 NOS
CT550 NOSCVI
550 NOS
CFT400 NOS
CGY450 NOS
CFB50 NOS
BC100 NOS
CFA900 NOS
CFT350 NOS
CVI450 NOS
CT650 NOS
CVI250 NOS
4201
700
0
6756NCA60 NOS
TOP VENT OPENING
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 4 of 4)
3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^ ^
900mm (H) CT SURROUNDTHE DOG HOUSE FORSCREENING OFF
^
^
^
^
^
^
900mm (H) CFC SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
52
08 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
Project
Museum for Visual Culture in West Kowloon Cultural District
Client Consultant
WKCDA
M+ Consultancy JV (MJV)
Element Other
3AXXX-TFP-LAN-REP-0001-LMP-WS2-XE Submission of Tree and Turf Grass Planting and Landscape Plans
Discipline
LAN
E 30 JUN 2020 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
D 22 MAR 2020 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
C 29 JUL 2015 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
B 11 Nov 2014 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
A 23 Jun 2014 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans For review
Rev Date Prepared by Checked by Approved by Endorsed by Description Status
Internal Review and Approval Table
F 30 JUN 2020 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
E 15 MAR 2020 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
D 29 JUL 2015 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
C 13 JUL 2015 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
B 11 Nov 2014 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
For approve
A 23 Jun 2014 Arup TFP Submission of Tree and Turf Grass Planting and Landscape Plans
Rev Date Prepared by Checked by Approved by Endorsed by Description Status
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
CHECKING ROUTING SHEET
CLIENT West Kowloon Cultural District Authority
PROJECT TITLE Consultancy Services for M+ Museum for Visual Culture in West Kowloon Cultural District
DOCUMENT TITLE Tree and Turf Grass Planting and Landscape Plan
(Rev E)
PREPARED BY NAME Stanley Sze
(ISA Certified Arbotist HK-0034A)
SIGNED DATE 30 June 2020
CHECKED BY NAME Lam Tak Wah (RLA 070)
SIGNED DATE 30 June 2020
1
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
Table of Content 1 OBJECTIVE AND PURPOSE OF THE REPORT 2 INTRODUCTION 3 LANDSCAPE TREE AND PLANTING PLAN 4 POST PLANTING CARE PLAN
Appendix A PLANTING PLANS AND SCHEDULE B NOT USED C GREEN COVERAGE PLANS D POST-PLANTING CARE PLAN
F SUPPLEMENTARY INFORMATION G IMPLEMENTATION PROGRAMME
H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
1 OBJECTIVE AND PURPOSE OF THE REPORT
111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approval under Section 8(3) of the EIA Ordinance (Appendix H) This report is only prepared for the M+ Museum because the Tree and Turf Grass Planting and Landscape Plan will be developed in phases as such there will not be an entire plan serving for the WKCD
112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on 04 August 2015
113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
2 INTRODUCTION
211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital part of any world-class cityrsquos economic and social fabric The West Kowloon Cultural District Authority (WKCDA) was established under the West Kowloon Cultural District Authority Ordinance (WKCDA Ordinance) Cap 601 to develop the WKCD (named ldquothe Siterdquo hereafter) The WKCD include
i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and as exhibition centre) other arts and cultural facilities (OACF) Retail Dining and Entertainment (RDE) facilities transport facilities and 23 ha public open space (which collectively constitute the ldquoCapital Projectsrdquo)
ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
iii) Major repair and renovation of the facilities and iv) Collection exhibition development conservation
laboratory equipment and library setup for the M+
212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
3 LANDSCAPE TREE AND PLANTING PLAN
31 Ground Floor and B1 Floor 311 Along the northern perimeter inter-planting of diverse trees forms a
thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent on the structural elements below grade Trees have been selected for their structural characteristics Eucalyptus tereticornis forms the upper canopy It is traditionally planted to form barriers and grows tall and straight very quickly It has fragrant leaves and flowers and lovely peeling bark The lower canopy consists of the native trees Sterculia lanceolata and Viburnum odoratissimum These species have an expressive and organic habit and will grow out and away from the Eucalyptus flank The understory is composed of Polyspora axillaris and Ligustrum sinense These are flowering small trees or large shrub with a light canopy and wide branching habit The species provides immediate screening at planting and bears a profusion of white flowers in spring and winter (refer to Table C and D) For the planting plan and planting schedule please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A accordingly
312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenable to the changing light conditions that will occur as the trees in front of the fenceline grow in (refer to Table E) For the planting plan and planting schedule please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A accordingly
313 Not used
314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely define zones
for congregation along the promenade Terminalia mantaly could reach to a potential height of 10-15 m and is distinguished by its erect stem and conspicuously layered branches It has smooth leaves with wavy margins that are bright green in youth held in terminal rosettes (refer to Table B) For the planting plan and planting schedule please refer to Drawing No 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 and 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 in Appendix A accordingly
315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appearance of a new planting In the same vein trees are to be planted at slightly irregular intervals and not on a straight line again to simulate more mature environmental habits of the species
316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high buildings they should a have a strong visual and spatial impact from the day of planting
317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively (refer to Table A)
318 Hydroseed turf grass is proposed at pedestrian zone of B1 floor and Ground floor covering approximately 1287 m2 which is 143 of the total greenery area The details of the percentage of grass coverage refer to Appendix C Further to the approval condition of EIAR-1782013 it is confirmed that Carpet Grass of the Axonopus genus including Axonopus compressus will not be planted within M+ Boundary for compliance Hydroseed species to refer to Appendix A accordingly
319 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B - Table F )
32 3 Floor Podium Roof 321 On the roof slabs of concrete are divided by long joints Built into the
strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a range of scaled gathering spaces Twelve related plant palettes composed largely of subtropical monocots have been selected for foliage suitability and form The selected species are marked by their subtle gradations and
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
modulations of colour as well as the formal architecture of their leaves and flowers These species are arranged into vegetative clans led by a majority species and supported by a set of supporting species Dense mass-planting of a restrained planting palette in wide swaths will generate a subtle graphic field condition legible from upper stories of the building as well as on the roof itself
322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cadence of vegetation that modulates in section as well as plan while still preserving sight lines across and over the flora towards the Hong Kong skyline and beyond This overall height scheme is altered in specific locations to provide for moments of greater insularity or exposure
323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles of the individual plants are to be left visible seedpods dried blooms etc are to be left on the plants nuancing the formal qualities of the scheme throughout the year
324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-LAN-DWG-0524-P00-L003-WS4 and 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4 in the Appendix A
325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
1 The site area of this project is approx 22966 m2 The green coverage is 9002774m2 22966m2 which is approximately 39
Table A ndash Greening Coverage Summary Table
Location Green Coverage (m2) Remarks
Green area at pedestrian zone
B1 Floor 297940 (GP3) Refer to Appendix C
Ground Floor 989065 (GP1 + GP2) Refer to Appendix C
Vertical Greenery at pedestrian zone
Green Area at Pedestrian zone
500556 (VP1 + VP2) Refer to Appendix C
Green area at 3 Floor Terrace Zone
3 Floor podium roof 7215213 (GT1-GT18) Refer to Appendix C
Total Greenery Area 9002774
Total Greenery Area Percentage
~ 391 Comply with the Master Register greenery
requirement 2
2 Based on the Approved West Kowloon Cultural District Development Plan No SK20WKCD2 there is a requirement for the provision of minimum green coverage of 30 and 60 for the whole WKCD and the Park respecvely
Table B- Tree Planng Schedule for B1 Floor
SCIENTIFIC NAME HEIGHT
(MM)
SPREAD (MM) DBH (MM) QTY
Terminalia mantaly 5000 3000 100 3 please refer to Drawing No 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 and 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 in Appendix A These 3 trees planng is planted at a planter interfacing with promenade planter and is subject to the planng design co-ordinaon with Promenade design
Table C- Tree Planng Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM)
SPREAD (MM)
DBH (MM) QTY
Eucalyptus tereticornis 5000 3000 75 4
Eucalyptus tereticornis 7000 4000 100 3
Sterculia lanceolata 4000 3000 100 4
Viburnum odoratissimum 3000 2000 75 2
nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
Table D- Large Shrub Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM) SPREAD (MM) QTY
Polyspora axillaris 2000 1000 17 Ligustrum sinense 2000 1000 18
nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
Table E- Climber Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM) SPACING (MM)
Campsis grandiflora 600 200 Ficus pumila 600 200 Epipremnum aureum 600 200 Lonicera japonica 600 200 Tristellateia australasiae 600 200 nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
Table F- Hydroseeding Seed Mix for Ground Floor SCIENTIFIC NAME RATE
Imperata cylindrica Varmajor 20 GSQM
Celosia argentea 5 GSQM Kalimeris indica 5 GSQM native species
4 POST PLANTING CARE PLAN
411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX A PLANTING PLANS AND SCHEDULE noitpircseD -on gniwarD
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 1 of 2) 3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 2 of 2) 3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 1 of 4) 3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 2 of 4) 3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 3 of 4) 3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 4 of 4) 3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 3F Shrubs and Groundcovers Schedule 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 1 of 2) 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 2 of 2)
1
7
6
5
4
A B C D E F
SPACE ALL TREESAT LEAST 5mFROM BASE OF WALL
AHU AHU
+1270+1260
250mm SURFACE CHANNEL
CLIMBER PLANTINGON CSF FACADE
1100 (H)BALUSTRADE
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
LOJ
TRA
(ALT
ERNA
TE P
LANT
ING)
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
FUEL PIPERUNNING IN SOILMATCH LINE
REFER to INSERT A
MIN 2000
MIN 2000
GF - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Et(l) EUCALYPTUS TERETICORNIS 細葉桉 5000 3000 75 4
Et(h) EUCALYPTUS TERETICORNIS 細葉桉 7000 4000 100 3
Sla STERCULIA LANCEOLATA 假蘋婆 4000 3000 100 4
Pax POLYSPORA AXILLARIS 大頭茶 2000 1000 - 17 MULTI-TRUNK
Lsi LIGUSTRUM SINENSE 山指甲 2000 1000 75 18
Vod VIBURNUM ODORATISSIMUM 珊瑚樹 3000 2000 75 2
GF CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 60000 - 20000 1200 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 60000 - 20000 1800 4 SHOOTS PER PLANT
EPA EPIPREMNUM AUREUM 綠蘿 60000 - 20000 400 4 SHOOTS PER PLANT
LOJ LONICERA JAPONICA 忍冬 金銀花 60000 - 20000 72 4 SHOOTS PER PLANT
TRA TRISTELLATEIA AUSTRALASIAE 三星果 60000 - 20000 72 4 SHOOTS PER PLANT
CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED AS STATED
HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
Native Species
2
1
7
6
A
AT LEAST 5mFROM BASE OF WALL
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
PLANTING AREA TO BEDESIGNED BY THE PARK
PLANTING AREA TO BEDESIGNED BY THE PARK
MATCH LINE
REFER to INSERT A
MIN 2000
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBERALONG WALL
TREE
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-G
AM-L
AN-D
WG
-900
3-P0
0-L0
00-W
S4
CAG
FIP
(ALTERNATE PLANTING)
SEDTRANSFER
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED SELF-CLINGING CLIMBER
PLANTING ON VERTICALBOUNDARY WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
EPA
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P 72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
retaW tlaS gnitsixEPumping Station
KRAP05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBBox
15P
A05P kraP gnicafretnI +M
N
04PM+
A93PB93P
FSCEDR
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 2)
3AXXX-GAM-LAN-DWG-9002-P01-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
1 100 SCALE BAR
0 25 5m
N KEY PLAN
MAIN PLAN
INSERT A
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
031
220
19 9
40
40 A
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
1
7
6
5
4
3
2
G H J K L M
CAG
FIP
(ALTERNATE PLANTING)
SELF-CLINGING CLIMBER
PLANTING ON VERTICAL
BOUNDARY WALL
ARTIST
SQUARE
CSF
STAFF
ENTRANCE
ST
PR
LT-51
LT-53
LT-52
ART
LIFT
ST
PR
MEP
UP
UP
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
STREET FIRE HYDRANT
P39B BOUNDARY
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
EPA
P39B BOUNDARY
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-G
AM
-L
AN
-D
WG
-9
00
2-P
00
-L
00
0-W
S4
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBER
ALONG WALL
PROPRIETARY WIRE
GREEN WALL SYSTEM
TREE
P39B HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
P39B CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 600 - 200 700 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 600 - 200 630 4 SHOOTS PER PLANT
ALL CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED
Native Species
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFSFIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Medium
Theatre I
Medium
Theatre IICCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega Perfo
rmance V
enue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREES
AND SHRUBS PLAN
(SHEET 2 of 2)
3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01
11102019 101916 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
1
2
3
4
5
6
7
7
HR
FS3-1-005B
PA250 NOS
CAP750 NOS
AW700 NOS
CAS650 NOS
HP250 NOS
IC350 NOS
HS50 NOS
IC350 NOS
AZ250 NOS
HS350 NOS
SR490 NOS
HP150 NOS
HP950 NOS
HP250 NOS
SR300 NOS
CAS200 NOS
CA515 NOS
JG350
HS250 NOS
HP450 NOS
HS350 NOS
CAS450 NOS
JG150 NOS
AW200 NOS
CAP700 NOS
SR600 NOS
AZ350 NOS PA
650 NOS
JG1250 NOS
CAS350 NOS
CA450 NOS
SR500 NOS
DFL150 NOS
ABO150 NOS
HP450 NOS
HS400 NOS
HS150 NOS
SR250 NOS
HP400 NOS
AZ50 NOS
AZ350 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
AZ750 NOS
CAP500 NOS
CA150 NOS
FFS30 NOS
AZ200 NOS
HP300 NOS
CAP400 NOS
DFL100 NOS
500500
500
500
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 4)
3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
900mm (H) HS SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
1100mm (H) HP SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
^
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
31
04 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
2
3
4
5
6
7
HR
FS3-1-005A
FS3-1-005BHR
ST-76
HP400 NOS
AZ50 NOS
CAS700 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
CAP500 NOS
AW350 NOS
HP300 NOS
SR550 NOS
HS650 NOS
DFL150 NOS CAP
350 NOS DFL220 NOS
SR250 NOS
AZ250 NOS
SR520 NOS
HP350 NOS SR
340 NOS
AZ600 NOS JG
450 NOS HS250 NOS
ABG100 NOS
AZ250 NOS
SR650 NOS
JG900 NOS
PA200 NOS
HP250 NOS
AW850 NOS
CAS850 NOS
CAP800 NOS
CAS850 NOS
SR350 NOS
PA500 NOS
HP300 NOS
500
500
0
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
5398
5085
5258
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 2 of 4)
3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
29
41 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
B C E FDA
HR
11
FS3-1-005B
CFA180 NOS
CFC250 NOS
CFC150 NOS
CFB450 NOS
CFA250 NOS
JG150 NOS
DE350 NOS
OJ3050 NOS
DE350 NOS
ZCI2100 NOS
CAS400 NOS
CGY50 NOS
CGY250 NOS
CFC250 NOS
CFA550 NOS
TS60 NOS
CGY250 NOS
CFT150 NOS
ABO80 NOS
CFT80 NOS
ABO60 NOS
JG150 NOS
CFC100 NOS
CFA150 NOS
CGY250 NOS
CFA250 NOS
CFT500 NOS
CFA300 NOS
YGC150 NOS
CAS150 NOS
CT200 NOS
TS50 NOS
CFC150 NOS
CGY350 NOS
CFB350 NOS
ZCA2000 NOS
DE550 NOS
ZCI1450 NOS
DE100 NOS
ZCA1200 NOS ZCI
4400 NOS
DE550 NOS
ZCI4250 NOS
JG150 NOS
CFC50 NOS
CGY500 NOS
CFB200 NOS
CFA450 NOS
BC200 NOS
CFA392 NOS
FFS25 NOS
CGY600 NOS
CAS250 NOS
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
BC350 NOS
CFC800 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
ZCI3550 NOSOJ
250 NOSZCI
1350 NOSDE
450 NOS
ZCA2250 NOS
NCA150 NOS
150 NOS
CGY450 NOS
CFB50 NOS
CFA300 NOS
CAS200 NOSCGY
250 NOSCFA520 NOS
FFS60 NOS
BC100 NOS
CTSON 051
500
500
500
500
500
500
500
500
CAS120 NOS
TOP VENT OPENING
900 x 900ACCESSHATCH
900 x 900ACCESSHATCH
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
NOTES
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 3 of 4)
3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
^
^
^
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
35
44 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
HR
11
FS3-1-005A
FS3-1-005BHR
ST-76
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
NCA150 NOS
CFA100 NOS
CVI150 NOS
CFT350 NOS
JG150 NOS ZCI
2000 NOS
NCA60 NOS
ZCA2300 NOS
CFC150 NOS
JG100 NOS
ZCA1250 NOS
ZCI2500 NOS
NCA250 NOS
ZCA400 NOS
CFT400 NOS
ZCI600 NOS
CT250 NOS
CFC650 NOS JG
110 NOS
CFC50 NOS
OJ1350 NOS
CFB160 NOS
CFA500 NOS
DE750 NOS
ZCA5050 NOS
OJ2650 NOS
ZCI3750 NOS
ZCA3850 NOS
CFT1150 NOS
CT450 NOS
CT250 NOSCAS
800 NOSJG250 NOS
CT950 NOS
CAS100 NOS
CGY350 NOS
CT350 NOS
CAS500 NOS
CFT200 NOS
CT150 NOS
OGY100 NOS
CFA550 NOS
CFC200 NOS
CVI150 NOS
FFS100 NOS
CFB150 NOS
JG200 NOS
ABG250 NOS
CFC750 NOS
CFA450 NOS
CFC300 NOS
CVI150 NOS
CFB100 NOS
TSC100 NOS
ZCA2000 NOS
CGY300 NOS
CFT1200 NOS
BC250 NOS
JG100 NOS
CFC60 NOS
CVI50 NOS
CFB100 NOS
CVI50 NOSCGY
100 NOS
CAS250 NOS
CGY300 NOS
CFA1000 NOS
CAS900 NOS
CT550 NOSCVI
550 NOS
CFT400 NOS
CGY450 NOS
CFB50 NOS
BC100 NOS
CFA900 NOS
CFT350 NOS
CVI450 NOS
CT650 NOS
CVI250 NOS
4201
700
0
6756NCA60 NOS
TOP VENT OPENING
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 4 of 4)
3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^ ^
900mm (H) CT SURROUNDTHE DOG HOUSE FORSCREENING OFF
^
^
^
^
^
^
900mm (H) CFC SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
52
08 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
CHECKING ROUTING SHEET
CLIENT West Kowloon Cultural District Authority
PROJECT TITLE Consultancy Services for M+ Museum for Visual Culture in West Kowloon Cultural District
DOCUMENT TITLE Tree and Turf Grass Planting and Landscape Plan
(Rev E)
PREPARED BY NAME Stanley Sze
(ISA Certified Arbotist HK-0034A)
SIGNED DATE 30 June 2020
CHECKED BY NAME Lam Tak Wah (RLA 070)
SIGNED DATE 30 June 2020
1
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
Table of Content 1 OBJECTIVE AND PURPOSE OF THE REPORT 2 INTRODUCTION 3 LANDSCAPE TREE AND PLANTING PLAN 4 POST PLANTING CARE PLAN
Appendix A PLANTING PLANS AND SCHEDULE B NOT USED C GREEN COVERAGE PLANS D POST-PLANTING CARE PLAN
F SUPPLEMENTARY INFORMATION G IMPLEMENTATION PROGRAMME
H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
1 OBJECTIVE AND PURPOSE OF THE REPORT
111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approval under Section 8(3) of the EIA Ordinance (Appendix H) This report is only prepared for the M+ Museum because the Tree and Turf Grass Planting and Landscape Plan will be developed in phases as such there will not be an entire plan serving for the WKCD
112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on 04 August 2015
113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
2 INTRODUCTION
211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital part of any world-class cityrsquos economic and social fabric The West Kowloon Cultural District Authority (WKCDA) was established under the West Kowloon Cultural District Authority Ordinance (WKCDA Ordinance) Cap 601 to develop the WKCD (named ldquothe Siterdquo hereafter) The WKCD include
i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and as exhibition centre) other arts and cultural facilities (OACF) Retail Dining and Entertainment (RDE) facilities transport facilities and 23 ha public open space (which collectively constitute the ldquoCapital Projectsrdquo)
ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
iii) Major repair and renovation of the facilities and iv) Collection exhibition development conservation
laboratory equipment and library setup for the M+
212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
3 LANDSCAPE TREE AND PLANTING PLAN
31 Ground Floor and B1 Floor 311 Along the northern perimeter inter-planting of diverse trees forms a
thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent on the structural elements below grade Trees have been selected for their structural characteristics Eucalyptus tereticornis forms the upper canopy It is traditionally planted to form barriers and grows tall and straight very quickly It has fragrant leaves and flowers and lovely peeling bark The lower canopy consists of the native trees Sterculia lanceolata and Viburnum odoratissimum These species have an expressive and organic habit and will grow out and away from the Eucalyptus flank The understory is composed of Polyspora axillaris and Ligustrum sinense These are flowering small trees or large shrub with a light canopy and wide branching habit The species provides immediate screening at planting and bears a profusion of white flowers in spring and winter (refer to Table C and D) For the planting plan and planting schedule please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A accordingly
312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenable to the changing light conditions that will occur as the trees in front of the fenceline grow in (refer to Table E) For the planting plan and planting schedule please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A accordingly
313 Not used
314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely define zones
for congregation along the promenade Terminalia mantaly could reach to a potential height of 10-15 m and is distinguished by its erect stem and conspicuously layered branches It has smooth leaves with wavy margins that are bright green in youth held in terminal rosettes (refer to Table B) For the planting plan and planting schedule please refer to Drawing No 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 and 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 in Appendix A accordingly
315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appearance of a new planting In the same vein trees are to be planted at slightly irregular intervals and not on a straight line again to simulate more mature environmental habits of the species
316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high buildings they should a have a strong visual and spatial impact from the day of planting
317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively (refer to Table A)
318 Hydroseed turf grass is proposed at pedestrian zone of B1 floor and Ground floor covering approximately 1287 m2 which is 143 of the total greenery area The details of the percentage of grass coverage refer to Appendix C Further to the approval condition of EIAR-1782013 it is confirmed that Carpet Grass of the Axonopus genus including Axonopus compressus will not be planted within M+ Boundary for compliance Hydroseed species to refer to Appendix A accordingly
319 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B - Table F )
32 3 Floor Podium Roof 321 On the roof slabs of concrete are divided by long joints Built into the
strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a range of scaled gathering spaces Twelve related plant palettes composed largely of subtropical monocots have been selected for foliage suitability and form The selected species are marked by their subtle gradations and
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
modulations of colour as well as the formal architecture of their leaves and flowers These species are arranged into vegetative clans led by a majority species and supported by a set of supporting species Dense mass-planting of a restrained planting palette in wide swaths will generate a subtle graphic field condition legible from upper stories of the building as well as on the roof itself
322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cadence of vegetation that modulates in section as well as plan while still preserving sight lines across and over the flora towards the Hong Kong skyline and beyond This overall height scheme is altered in specific locations to provide for moments of greater insularity or exposure
323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles of the individual plants are to be left visible seedpods dried blooms etc are to be left on the plants nuancing the formal qualities of the scheme throughout the year
324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-LAN-DWG-0524-P00-L003-WS4 and 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4 in the Appendix A
325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
1 The site area of this project is approx 22966 m2 The green coverage is 9002774m2 22966m2 which is approximately 39
Table A ndash Greening Coverage Summary Table
Location Green Coverage (m2) Remarks
Green area at pedestrian zone
B1 Floor 297940 (GP3) Refer to Appendix C
Ground Floor 989065 (GP1 + GP2) Refer to Appendix C
Vertical Greenery at pedestrian zone
Green Area at Pedestrian zone
500556 (VP1 + VP2) Refer to Appendix C
Green area at 3 Floor Terrace Zone
3 Floor podium roof 7215213 (GT1-GT18) Refer to Appendix C
Total Greenery Area 9002774
Total Greenery Area Percentage
~ 391 Comply with the Master Register greenery
requirement 2
2 Based on the Approved West Kowloon Cultural District Development Plan No SK20WKCD2 there is a requirement for the provision of minimum green coverage of 30 and 60 for the whole WKCD and the Park respecvely
Table B- Tree Planng Schedule for B1 Floor
SCIENTIFIC NAME HEIGHT
(MM)
SPREAD (MM) DBH (MM) QTY
Terminalia mantaly 5000 3000 100 3 please refer to Drawing No 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 and 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 in Appendix A These 3 trees planng is planted at a planter interfacing with promenade planter and is subject to the planng design co-ordinaon with Promenade design
Table C- Tree Planng Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM)
SPREAD (MM)
DBH (MM) QTY
Eucalyptus tereticornis 5000 3000 75 4
Eucalyptus tereticornis 7000 4000 100 3
Sterculia lanceolata 4000 3000 100 4
Viburnum odoratissimum 3000 2000 75 2
nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
Table D- Large Shrub Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM) SPREAD (MM) QTY
Polyspora axillaris 2000 1000 17 Ligustrum sinense 2000 1000 18
nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
Table E- Climber Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM) SPACING (MM)
Campsis grandiflora 600 200 Ficus pumila 600 200 Epipremnum aureum 600 200 Lonicera japonica 600 200 Tristellateia australasiae 600 200 nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
Table F- Hydroseeding Seed Mix for Ground Floor SCIENTIFIC NAME RATE
Imperata cylindrica Varmajor 20 GSQM
Celosia argentea 5 GSQM Kalimeris indica 5 GSQM native species
4 POST PLANTING CARE PLAN
411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX A PLANTING PLANS AND SCHEDULE noitpircseD -on gniwarD
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 1 of 2) 3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 2 of 2) 3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 1 of 4) 3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 2 of 4) 3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 3 of 4) 3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 4 of 4) 3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 3F Shrubs and Groundcovers Schedule 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 1 of 2) 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 2 of 2)
1
7
6
5
4
A B C D E F
SPACE ALL TREESAT LEAST 5mFROM BASE OF WALL
AHU AHU
+1270+1260
250mm SURFACE CHANNEL
CLIMBER PLANTINGON CSF FACADE
1100 (H)BALUSTRADE
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
LOJ
TRA
(ALT
ERNA
TE P
LANT
ING)
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
FUEL PIPERUNNING IN SOILMATCH LINE
REFER to INSERT A
MIN 2000
MIN 2000
GF - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Et(l) EUCALYPTUS TERETICORNIS 細葉桉 5000 3000 75 4
Et(h) EUCALYPTUS TERETICORNIS 細葉桉 7000 4000 100 3
Sla STERCULIA LANCEOLATA 假蘋婆 4000 3000 100 4
Pax POLYSPORA AXILLARIS 大頭茶 2000 1000 - 17 MULTI-TRUNK
Lsi LIGUSTRUM SINENSE 山指甲 2000 1000 75 18
Vod VIBURNUM ODORATISSIMUM 珊瑚樹 3000 2000 75 2
GF CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 60000 - 20000 1200 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 60000 - 20000 1800 4 SHOOTS PER PLANT
EPA EPIPREMNUM AUREUM 綠蘿 60000 - 20000 400 4 SHOOTS PER PLANT
LOJ LONICERA JAPONICA 忍冬 金銀花 60000 - 20000 72 4 SHOOTS PER PLANT
TRA TRISTELLATEIA AUSTRALASIAE 三星果 60000 - 20000 72 4 SHOOTS PER PLANT
CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED AS STATED
HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
Native Species
2
1
7
6
A
AT LEAST 5mFROM BASE OF WALL
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
PLANTING AREA TO BEDESIGNED BY THE PARK
PLANTING AREA TO BEDESIGNED BY THE PARK
MATCH LINE
REFER to INSERT A
MIN 2000
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBERALONG WALL
TREE
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-G
AM-L
AN-D
WG
-900
3-P0
0-L0
00-W
S4
CAG
FIP
(ALTERNATE PLANTING)
SEDTRANSFER
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED SELF-CLINGING CLIMBER
PLANTING ON VERTICALBOUNDARY WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
EPA
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P 72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
retaW tlaS gnitsixEPumping Station
KRAP05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBBox
15P
A05P kraP gnicafretnI +M
N
04PM+
A93PB93P
FSCEDR
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 2)
3AXXX-GAM-LAN-DWG-9002-P01-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
1 100 SCALE BAR
0 25 5m
N KEY PLAN
MAIN PLAN
INSERT A
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
031
220
19 9
40
40 A
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
1
7
6
5
4
3
2
G H J K L M
CAG
FIP
(ALTERNATE PLANTING)
SELF-CLINGING CLIMBER
PLANTING ON VERTICAL
BOUNDARY WALL
ARTIST
SQUARE
CSF
STAFF
ENTRANCE
ST
PR
LT-51
LT-53
LT-52
ART
LIFT
ST
PR
MEP
UP
UP
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
STREET FIRE HYDRANT
P39B BOUNDARY
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
EPA
P39B BOUNDARY
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-G
AM
-L
AN
-D
WG
-9
00
2-P
00
-L
00
0-W
S4
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBER
ALONG WALL
PROPRIETARY WIRE
GREEN WALL SYSTEM
TREE
P39B HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
P39B CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 600 - 200 700 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 600 - 200 630 4 SHOOTS PER PLANT
ALL CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED
Native Species
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFSFIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Medium
Theatre I
Medium
Theatre IICCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega Perfo
rmance V
enue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREES
AND SHRUBS PLAN
(SHEET 2 of 2)
3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01
11102019 101916 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
1
2
3
4
5
6
7
7
HR
FS3-1-005B
PA250 NOS
CAP750 NOS
AW700 NOS
CAS650 NOS
HP250 NOS
IC350 NOS
HS50 NOS
IC350 NOS
AZ250 NOS
HS350 NOS
SR490 NOS
HP150 NOS
HP950 NOS
HP250 NOS
SR300 NOS
CAS200 NOS
CA515 NOS
JG350
HS250 NOS
HP450 NOS
HS350 NOS
CAS450 NOS
JG150 NOS
AW200 NOS
CAP700 NOS
SR600 NOS
AZ350 NOS PA
650 NOS
JG1250 NOS
CAS350 NOS
CA450 NOS
SR500 NOS
DFL150 NOS
ABO150 NOS
HP450 NOS
HS400 NOS
HS150 NOS
SR250 NOS
HP400 NOS
AZ50 NOS
AZ350 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
AZ750 NOS
CAP500 NOS
CA150 NOS
FFS30 NOS
AZ200 NOS
HP300 NOS
CAP400 NOS
DFL100 NOS
500500
500
500
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 4)
3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
900mm (H) HS SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
1100mm (H) HP SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
^
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
31
04 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
2
3
4
5
6
7
HR
FS3-1-005A
FS3-1-005BHR
ST-76
HP400 NOS
AZ50 NOS
CAS700 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
CAP500 NOS
AW350 NOS
HP300 NOS
SR550 NOS
HS650 NOS
DFL150 NOS CAP
350 NOS DFL220 NOS
SR250 NOS
AZ250 NOS
SR520 NOS
HP350 NOS SR
340 NOS
AZ600 NOS JG
450 NOS HS250 NOS
ABG100 NOS
AZ250 NOS
SR650 NOS
JG900 NOS
PA200 NOS
HP250 NOS
AW850 NOS
CAS850 NOS
CAP800 NOS
CAS850 NOS
SR350 NOS
PA500 NOS
HP300 NOS
500
500
0
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
5398
5085
5258
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 2 of 4)
3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
29
41 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
B C E FDA
HR
11
FS3-1-005B
CFA180 NOS
CFC250 NOS
CFC150 NOS
CFB450 NOS
CFA250 NOS
JG150 NOS
DE350 NOS
OJ3050 NOS
DE350 NOS
ZCI2100 NOS
CAS400 NOS
CGY50 NOS
CGY250 NOS
CFC250 NOS
CFA550 NOS
TS60 NOS
CGY250 NOS
CFT150 NOS
ABO80 NOS
CFT80 NOS
ABO60 NOS
JG150 NOS
CFC100 NOS
CFA150 NOS
CGY250 NOS
CFA250 NOS
CFT500 NOS
CFA300 NOS
YGC150 NOS
CAS150 NOS
CT200 NOS
TS50 NOS
CFC150 NOS
CGY350 NOS
CFB350 NOS
ZCA2000 NOS
DE550 NOS
ZCI1450 NOS
DE100 NOS
ZCA1200 NOS ZCI
4400 NOS
DE550 NOS
ZCI4250 NOS
JG150 NOS
CFC50 NOS
CGY500 NOS
CFB200 NOS
CFA450 NOS
BC200 NOS
CFA392 NOS
FFS25 NOS
CGY600 NOS
CAS250 NOS
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
BC350 NOS
CFC800 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
ZCI3550 NOSOJ
250 NOSZCI
1350 NOSDE
450 NOS
ZCA2250 NOS
NCA150 NOS
150 NOS
CGY450 NOS
CFB50 NOS
CFA300 NOS
CAS200 NOSCGY
250 NOSCFA520 NOS
FFS60 NOS
BC100 NOS
CTSON 051
500
500
500
500
500
500
500
500
CAS120 NOS
TOP VENT OPENING
900 x 900ACCESSHATCH
900 x 900ACCESSHATCH
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
NOTES
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 3 of 4)
3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
^
^
^
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
35
44 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
HR
11
FS3-1-005A
FS3-1-005BHR
ST-76
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
NCA150 NOS
CFA100 NOS
CVI150 NOS
CFT350 NOS
JG150 NOS ZCI
2000 NOS
NCA60 NOS
ZCA2300 NOS
CFC150 NOS
JG100 NOS
ZCA1250 NOS
ZCI2500 NOS
NCA250 NOS
ZCA400 NOS
CFT400 NOS
ZCI600 NOS
CT250 NOS
CFC650 NOS JG
110 NOS
CFC50 NOS
OJ1350 NOS
CFB160 NOS
CFA500 NOS
DE750 NOS
ZCA5050 NOS
OJ2650 NOS
ZCI3750 NOS
ZCA3850 NOS
CFT1150 NOS
CT450 NOS
CT250 NOSCAS
800 NOSJG250 NOS
CT950 NOS
CAS100 NOS
CGY350 NOS
CT350 NOS
CAS500 NOS
CFT200 NOS
CT150 NOS
OGY100 NOS
CFA550 NOS
CFC200 NOS
CVI150 NOS
FFS100 NOS
CFB150 NOS
JG200 NOS
ABG250 NOS
CFC750 NOS
CFA450 NOS
CFC300 NOS
CVI150 NOS
CFB100 NOS
TSC100 NOS
ZCA2000 NOS
CGY300 NOS
CFT1200 NOS
BC250 NOS
JG100 NOS
CFC60 NOS
CVI50 NOS
CFB100 NOS
CVI50 NOSCGY
100 NOS
CAS250 NOS
CGY300 NOS
CFA1000 NOS
CAS900 NOS
CT550 NOSCVI
550 NOS
CFT400 NOS
CGY450 NOS
CFB50 NOS
BC100 NOS
CFA900 NOS
CFT350 NOS
CVI450 NOS
CT650 NOS
CVI250 NOS
4201
700
0
6756NCA60 NOS
TOP VENT OPENING
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 4 of 4)
3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^ ^
900mm (H) CT SURROUNDTHE DOG HOUSE FORSCREENING OFF
^
^
^
^
^
^
900mm (H) CFC SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
52
08 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
Table of Content 1 OBJECTIVE AND PURPOSE OF THE REPORT 2 INTRODUCTION 3 LANDSCAPE TREE AND PLANTING PLAN 4 POST PLANTING CARE PLAN
Appendix A PLANTING PLANS AND SCHEDULE B NOT USED C GREEN COVERAGE PLANS D POST-PLANTING CARE PLAN
F SUPPLEMENTARY INFORMATION G IMPLEMENTATION PROGRAMME
H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
1 OBJECTIVE AND PURPOSE OF THE REPORT
111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approval under Section 8(3) of the EIA Ordinance (Appendix H) This report is only prepared for the M+ Museum because the Tree and Turf Grass Planting and Landscape Plan will be developed in phases as such there will not be an entire plan serving for the WKCD
112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on 04 August 2015
113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
2 INTRODUCTION
211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital part of any world-class cityrsquos economic and social fabric The West Kowloon Cultural District Authority (WKCDA) was established under the West Kowloon Cultural District Authority Ordinance (WKCDA Ordinance) Cap 601 to develop the WKCD (named ldquothe Siterdquo hereafter) The WKCD include
i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and as exhibition centre) other arts and cultural facilities (OACF) Retail Dining and Entertainment (RDE) facilities transport facilities and 23 ha public open space (which collectively constitute the ldquoCapital Projectsrdquo)
ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
iii) Major repair and renovation of the facilities and iv) Collection exhibition development conservation
laboratory equipment and library setup for the M+
212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
3 LANDSCAPE TREE AND PLANTING PLAN
31 Ground Floor and B1 Floor 311 Along the northern perimeter inter-planting of diverse trees forms a
thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent on the structural elements below grade Trees have been selected for their structural characteristics Eucalyptus tereticornis forms the upper canopy It is traditionally planted to form barriers and grows tall and straight very quickly It has fragrant leaves and flowers and lovely peeling bark The lower canopy consists of the native trees Sterculia lanceolata and Viburnum odoratissimum These species have an expressive and organic habit and will grow out and away from the Eucalyptus flank The understory is composed of Polyspora axillaris and Ligustrum sinense These are flowering small trees or large shrub with a light canopy and wide branching habit The species provides immediate screening at planting and bears a profusion of white flowers in spring and winter (refer to Table C and D) For the planting plan and planting schedule please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A accordingly
312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenable to the changing light conditions that will occur as the trees in front of the fenceline grow in (refer to Table E) For the planting plan and planting schedule please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A accordingly
313 Not used
314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely define zones
for congregation along the promenade Terminalia mantaly could reach to a potential height of 10-15 m and is distinguished by its erect stem and conspicuously layered branches It has smooth leaves with wavy margins that are bright green in youth held in terminal rosettes (refer to Table B) For the planting plan and planting schedule please refer to Drawing No 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 and 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 in Appendix A accordingly
315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appearance of a new planting In the same vein trees are to be planted at slightly irregular intervals and not on a straight line again to simulate more mature environmental habits of the species
316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high buildings they should a have a strong visual and spatial impact from the day of planting
317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively (refer to Table A)
318 Hydroseed turf grass is proposed at pedestrian zone of B1 floor and Ground floor covering approximately 1287 m2 which is 143 of the total greenery area The details of the percentage of grass coverage refer to Appendix C Further to the approval condition of EIAR-1782013 it is confirmed that Carpet Grass of the Axonopus genus including Axonopus compressus will not be planted within M+ Boundary for compliance Hydroseed species to refer to Appendix A accordingly
319 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B - Table F )
32 3 Floor Podium Roof 321 On the roof slabs of concrete are divided by long joints Built into the
strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a range of scaled gathering spaces Twelve related plant palettes composed largely of subtropical monocots have been selected for foliage suitability and form The selected species are marked by their subtle gradations and
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
modulations of colour as well as the formal architecture of their leaves and flowers These species are arranged into vegetative clans led by a majority species and supported by a set of supporting species Dense mass-planting of a restrained planting palette in wide swaths will generate a subtle graphic field condition legible from upper stories of the building as well as on the roof itself
322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cadence of vegetation that modulates in section as well as plan while still preserving sight lines across and over the flora towards the Hong Kong skyline and beyond This overall height scheme is altered in specific locations to provide for moments of greater insularity or exposure
323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles of the individual plants are to be left visible seedpods dried blooms etc are to be left on the plants nuancing the formal qualities of the scheme throughout the year
324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-LAN-DWG-0524-P00-L003-WS4 and 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4 in the Appendix A
325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
1 The site area of this project is approx 22966 m2 The green coverage is 9002774m2 22966m2 which is approximately 39
Table A ndash Greening Coverage Summary Table
Location Green Coverage (m2) Remarks
Green area at pedestrian zone
B1 Floor 297940 (GP3) Refer to Appendix C
Ground Floor 989065 (GP1 + GP2) Refer to Appendix C
Vertical Greenery at pedestrian zone
Green Area at Pedestrian zone
500556 (VP1 + VP2) Refer to Appendix C
Green area at 3 Floor Terrace Zone
3 Floor podium roof 7215213 (GT1-GT18) Refer to Appendix C
Total Greenery Area 9002774
Total Greenery Area Percentage
~ 391 Comply with the Master Register greenery
requirement 2
2 Based on the Approved West Kowloon Cultural District Development Plan No SK20WKCD2 there is a requirement for the provision of minimum green coverage of 30 and 60 for the whole WKCD and the Park respecvely
Table B- Tree Planng Schedule for B1 Floor
SCIENTIFIC NAME HEIGHT
(MM)
SPREAD (MM) DBH (MM) QTY
Terminalia mantaly 5000 3000 100 3 please refer to Drawing No 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 and 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 in Appendix A These 3 trees planng is planted at a planter interfacing with promenade planter and is subject to the planng design co-ordinaon with Promenade design
Table C- Tree Planng Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM)
SPREAD (MM)
DBH (MM) QTY
Eucalyptus tereticornis 5000 3000 75 4
Eucalyptus tereticornis 7000 4000 100 3
Sterculia lanceolata 4000 3000 100 4
Viburnum odoratissimum 3000 2000 75 2
nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
Table D- Large Shrub Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM) SPREAD (MM) QTY
Polyspora axillaris 2000 1000 17 Ligustrum sinense 2000 1000 18
nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
Table E- Climber Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM) SPACING (MM)
Campsis grandiflora 600 200 Ficus pumila 600 200 Epipremnum aureum 600 200 Lonicera japonica 600 200 Tristellateia australasiae 600 200 nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
Table F- Hydroseeding Seed Mix for Ground Floor SCIENTIFIC NAME RATE
Imperata cylindrica Varmajor 20 GSQM
Celosia argentea 5 GSQM Kalimeris indica 5 GSQM native species
4 POST PLANTING CARE PLAN
411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX A PLANTING PLANS AND SCHEDULE noitpircseD -on gniwarD
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 1 of 2) 3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 2 of 2) 3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 1 of 4) 3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 2 of 4) 3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 3 of 4) 3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 4 of 4) 3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 3F Shrubs and Groundcovers Schedule 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 1 of 2) 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 2 of 2)
1
7
6
5
4
A B C D E F
SPACE ALL TREESAT LEAST 5mFROM BASE OF WALL
AHU AHU
+1270+1260
250mm SURFACE CHANNEL
CLIMBER PLANTINGON CSF FACADE
1100 (H)BALUSTRADE
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
LOJ
TRA
(ALT
ERNA
TE P
LANT
ING)
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
FUEL PIPERUNNING IN SOILMATCH LINE
REFER to INSERT A
MIN 2000
MIN 2000
GF - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Et(l) EUCALYPTUS TERETICORNIS 細葉桉 5000 3000 75 4
Et(h) EUCALYPTUS TERETICORNIS 細葉桉 7000 4000 100 3
Sla STERCULIA LANCEOLATA 假蘋婆 4000 3000 100 4
Pax POLYSPORA AXILLARIS 大頭茶 2000 1000 - 17 MULTI-TRUNK
Lsi LIGUSTRUM SINENSE 山指甲 2000 1000 75 18
Vod VIBURNUM ODORATISSIMUM 珊瑚樹 3000 2000 75 2
GF CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 60000 - 20000 1200 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 60000 - 20000 1800 4 SHOOTS PER PLANT
EPA EPIPREMNUM AUREUM 綠蘿 60000 - 20000 400 4 SHOOTS PER PLANT
LOJ LONICERA JAPONICA 忍冬 金銀花 60000 - 20000 72 4 SHOOTS PER PLANT
TRA TRISTELLATEIA AUSTRALASIAE 三星果 60000 - 20000 72 4 SHOOTS PER PLANT
CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED AS STATED
HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
Native Species
2
1
7
6
A
AT LEAST 5mFROM BASE OF WALL
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
PLANTING AREA TO BEDESIGNED BY THE PARK
PLANTING AREA TO BEDESIGNED BY THE PARK
MATCH LINE
REFER to INSERT A
MIN 2000
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBERALONG WALL
TREE
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-G
AM-L
AN-D
WG
-900
3-P0
0-L0
00-W
S4
CAG
FIP
(ALTERNATE PLANTING)
SEDTRANSFER
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED SELF-CLINGING CLIMBER
PLANTING ON VERTICALBOUNDARY WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
EPA
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P 72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
retaW tlaS gnitsixEPumping Station
KRAP05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBBox
15P
A05P kraP gnicafretnI +M
N
04PM+
A93PB93P
FSCEDR
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 2)
3AXXX-GAM-LAN-DWG-9002-P01-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
1 100 SCALE BAR
0 25 5m
N KEY PLAN
MAIN PLAN
INSERT A
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
031
220
19 9
40
40 A
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
1
7
6
5
4
3
2
G H J K L M
CAG
FIP
(ALTERNATE PLANTING)
SELF-CLINGING CLIMBER
PLANTING ON VERTICAL
BOUNDARY WALL
ARTIST
SQUARE
CSF
STAFF
ENTRANCE
ST
PR
LT-51
LT-53
LT-52
ART
LIFT
ST
PR
MEP
UP
UP
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
STREET FIRE HYDRANT
P39B BOUNDARY
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
EPA
P39B BOUNDARY
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-G
AM
-L
AN
-D
WG
-9
00
2-P
00
-L
00
0-W
S4
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBER
ALONG WALL
PROPRIETARY WIRE
GREEN WALL SYSTEM
TREE
P39B HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
P39B CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 600 - 200 700 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 600 - 200 630 4 SHOOTS PER PLANT
ALL CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED
Native Species
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFSFIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Medium
Theatre I
Medium
Theatre IICCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega Perfo
rmance V
enue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREES
AND SHRUBS PLAN
(SHEET 2 of 2)
3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01
11102019 101916 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
1
2
3
4
5
6
7
7
HR
FS3-1-005B
PA250 NOS
CAP750 NOS
AW700 NOS
CAS650 NOS
HP250 NOS
IC350 NOS
HS50 NOS
IC350 NOS
AZ250 NOS
HS350 NOS
SR490 NOS
HP150 NOS
HP950 NOS
HP250 NOS
SR300 NOS
CAS200 NOS
CA515 NOS
JG350
HS250 NOS
HP450 NOS
HS350 NOS
CAS450 NOS
JG150 NOS
AW200 NOS
CAP700 NOS
SR600 NOS
AZ350 NOS PA
650 NOS
JG1250 NOS
CAS350 NOS
CA450 NOS
SR500 NOS
DFL150 NOS
ABO150 NOS
HP450 NOS
HS400 NOS
HS150 NOS
SR250 NOS
HP400 NOS
AZ50 NOS
AZ350 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
AZ750 NOS
CAP500 NOS
CA150 NOS
FFS30 NOS
AZ200 NOS
HP300 NOS
CAP400 NOS
DFL100 NOS
500500
500
500
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 4)
3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
900mm (H) HS SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
1100mm (H) HP SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
^
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
31
04 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
2
3
4
5
6
7
HR
FS3-1-005A
FS3-1-005BHR
ST-76
HP400 NOS
AZ50 NOS
CAS700 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
CAP500 NOS
AW350 NOS
HP300 NOS
SR550 NOS
HS650 NOS
DFL150 NOS CAP
350 NOS DFL220 NOS
SR250 NOS
AZ250 NOS
SR520 NOS
HP350 NOS SR
340 NOS
AZ600 NOS JG
450 NOS HS250 NOS
ABG100 NOS
AZ250 NOS
SR650 NOS
JG900 NOS
PA200 NOS
HP250 NOS
AW850 NOS
CAS850 NOS
CAP800 NOS
CAS850 NOS
SR350 NOS
PA500 NOS
HP300 NOS
500
500
0
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
5398
5085
5258
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 2 of 4)
3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
29
41 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
B C E FDA
HR
11
FS3-1-005B
CFA180 NOS
CFC250 NOS
CFC150 NOS
CFB450 NOS
CFA250 NOS
JG150 NOS
DE350 NOS
OJ3050 NOS
DE350 NOS
ZCI2100 NOS
CAS400 NOS
CGY50 NOS
CGY250 NOS
CFC250 NOS
CFA550 NOS
TS60 NOS
CGY250 NOS
CFT150 NOS
ABO80 NOS
CFT80 NOS
ABO60 NOS
JG150 NOS
CFC100 NOS
CFA150 NOS
CGY250 NOS
CFA250 NOS
CFT500 NOS
CFA300 NOS
YGC150 NOS
CAS150 NOS
CT200 NOS
TS50 NOS
CFC150 NOS
CGY350 NOS
CFB350 NOS
ZCA2000 NOS
DE550 NOS
ZCI1450 NOS
DE100 NOS
ZCA1200 NOS ZCI
4400 NOS
DE550 NOS
ZCI4250 NOS
JG150 NOS
CFC50 NOS
CGY500 NOS
CFB200 NOS
CFA450 NOS
BC200 NOS
CFA392 NOS
FFS25 NOS
CGY600 NOS
CAS250 NOS
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
BC350 NOS
CFC800 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
ZCI3550 NOSOJ
250 NOSZCI
1350 NOSDE
450 NOS
ZCA2250 NOS
NCA150 NOS
150 NOS
CGY450 NOS
CFB50 NOS
CFA300 NOS
CAS200 NOSCGY
250 NOSCFA520 NOS
FFS60 NOS
BC100 NOS
CTSON 051
500
500
500
500
500
500
500
500
CAS120 NOS
TOP VENT OPENING
900 x 900ACCESSHATCH
900 x 900ACCESSHATCH
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
NOTES
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 3 of 4)
3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
^
^
^
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
35
44 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
HR
11
FS3-1-005A
FS3-1-005BHR
ST-76
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
NCA150 NOS
CFA100 NOS
CVI150 NOS
CFT350 NOS
JG150 NOS ZCI
2000 NOS
NCA60 NOS
ZCA2300 NOS
CFC150 NOS
JG100 NOS
ZCA1250 NOS
ZCI2500 NOS
NCA250 NOS
ZCA400 NOS
CFT400 NOS
ZCI600 NOS
CT250 NOS
CFC650 NOS JG
110 NOS
CFC50 NOS
OJ1350 NOS
CFB160 NOS
CFA500 NOS
DE750 NOS
ZCA5050 NOS
OJ2650 NOS
ZCI3750 NOS
ZCA3850 NOS
CFT1150 NOS
CT450 NOS
CT250 NOSCAS
800 NOSJG250 NOS
CT950 NOS
CAS100 NOS
CGY350 NOS
CT350 NOS
CAS500 NOS
CFT200 NOS
CT150 NOS
OGY100 NOS
CFA550 NOS
CFC200 NOS
CVI150 NOS
FFS100 NOS
CFB150 NOS
JG200 NOS
ABG250 NOS
CFC750 NOS
CFA450 NOS
CFC300 NOS
CVI150 NOS
CFB100 NOS
TSC100 NOS
ZCA2000 NOS
CGY300 NOS
CFT1200 NOS
BC250 NOS
JG100 NOS
CFC60 NOS
CVI50 NOS
CFB100 NOS
CVI50 NOSCGY
100 NOS
CAS250 NOS
CGY300 NOS
CFA1000 NOS
CAS900 NOS
CT550 NOSCVI
550 NOS
CFT400 NOS
CGY450 NOS
CFB50 NOS
BC100 NOS
CFA900 NOS
CFT350 NOS
CVI450 NOS
CT650 NOS
CVI250 NOS
4201
700
0
6756NCA60 NOS
TOP VENT OPENING
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 4 of 4)
3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^ ^
900mm (H) CT SURROUNDTHE DOG HOUSE FORSCREENING OFF
^
^
^
^
^
^
900mm (H) CFC SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
52
08 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
1 OBJECTIVE AND PURPOSE OF THE REPORT
111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approval under Section 8(3) of the EIA Ordinance (Appendix H) This report is only prepared for the M+ Museum because the Tree and Turf Grass Planting and Landscape Plan will be developed in phases as such there will not be an entire plan serving for the WKCD
112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on 04 August 2015
113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
2 INTRODUCTION
211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital part of any world-class cityrsquos economic and social fabric The West Kowloon Cultural District Authority (WKCDA) was established under the West Kowloon Cultural District Authority Ordinance (WKCDA Ordinance) Cap 601 to develop the WKCD (named ldquothe Siterdquo hereafter) The WKCD include
i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and as exhibition centre) other arts and cultural facilities (OACF) Retail Dining and Entertainment (RDE) facilities transport facilities and 23 ha public open space (which collectively constitute the ldquoCapital Projectsrdquo)
ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
iii) Major repair and renovation of the facilities and iv) Collection exhibition development conservation
laboratory equipment and library setup for the M+
212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
3 LANDSCAPE TREE AND PLANTING PLAN
31 Ground Floor and B1 Floor 311 Along the northern perimeter inter-planting of diverse trees forms a
thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent on the structural elements below grade Trees have been selected for their structural characteristics Eucalyptus tereticornis forms the upper canopy It is traditionally planted to form barriers and grows tall and straight very quickly It has fragrant leaves and flowers and lovely peeling bark The lower canopy consists of the native trees Sterculia lanceolata and Viburnum odoratissimum These species have an expressive and organic habit and will grow out and away from the Eucalyptus flank The understory is composed of Polyspora axillaris and Ligustrum sinense These are flowering small trees or large shrub with a light canopy and wide branching habit The species provides immediate screening at planting and bears a profusion of white flowers in spring and winter (refer to Table C and D) For the planting plan and planting schedule please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A accordingly
312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenable to the changing light conditions that will occur as the trees in front of the fenceline grow in (refer to Table E) For the planting plan and planting schedule please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A accordingly
313 Not used
314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely define zones
for congregation along the promenade Terminalia mantaly could reach to a potential height of 10-15 m and is distinguished by its erect stem and conspicuously layered branches It has smooth leaves with wavy margins that are bright green in youth held in terminal rosettes (refer to Table B) For the planting plan and planting schedule please refer to Drawing No 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 and 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 in Appendix A accordingly
315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appearance of a new planting In the same vein trees are to be planted at slightly irregular intervals and not on a straight line again to simulate more mature environmental habits of the species
316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high buildings they should a have a strong visual and spatial impact from the day of planting
317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively (refer to Table A)
318 Hydroseed turf grass is proposed at pedestrian zone of B1 floor and Ground floor covering approximately 1287 m2 which is 143 of the total greenery area The details of the percentage of grass coverage refer to Appendix C Further to the approval condition of EIAR-1782013 it is confirmed that Carpet Grass of the Axonopus genus including Axonopus compressus will not be planted within M+ Boundary for compliance Hydroseed species to refer to Appendix A accordingly
319 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B - Table F )
32 3 Floor Podium Roof 321 On the roof slabs of concrete are divided by long joints Built into the
strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a range of scaled gathering spaces Twelve related plant palettes composed largely of subtropical monocots have been selected for foliage suitability and form The selected species are marked by their subtle gradations and
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
modulations of colour as well as the formal architecture of their leaves and flowers These species are arranged into vegetative clans led by a majority species and supported by a set of supporting species Dense mass-planting of a restrained planting palette in wide swaths will generate a subtle graphic field condition legible from upper stories of the building as well as on the roof itself
322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cadence of vegetation that modulates in section as well as plan while still preserving sight lines across and over the flora towards the Hong Kong skyline and beyond This overall height scheme is altered in specific locations to provide for moments of greater insularity or exposure
323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles of the individual plants are to be left visible seedpods dried blooms etc are to be left on the plants nuancing the formal qualities of the scheme throughout the year
324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-LAN-DWG-0524-P00-L003-WS4 and 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4 in the Appendix A
325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
1 The site area of this project is approx 22966 m2 The green coverage is 9002774m2 22966m2 which is approximately 39
Table A ndash Greening Coverage Summary Table
Location Green Coverage (m2) Remarks
Green area at pedestrian zone
B1 Floor 297940 (GP3) Refer to Appendix C
Ground Floor 989065 (GP1 + GP2) Refer to Appendix C
Vertical Greenery at pedestrian zone
Green Area at Pedestrian zone
500556 (VP1 + VP2) Refer to Appendix C
Green area at 3 Floor Terrace Zone
3 Floor podium roof 7215213 (GT1-GT18) Refer to Appendix C
Total Greenery Area 9002774
Total Greenery Area Percentage
~ 391 Comply with the Master Register greenery
requirement 2
2 Based on the Approved West Kowloon Cultural District Development Plan No SK20WKCD2 there is a requirement for the provision of minimum green coverage of 30 and 60 for the whole WKCD and the Park respecvely
Table B- Tree Planng Schedule for B1 Floor
SCIENTIFIC NAME HEIGHT
(MM)
SPREAD (MM) DBH (MM) QTY
Terminalia mantaly 5000 3000 100 3 please refer to Drawing No 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 and 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 in Appendix A These 3 trees planng is planted at a planter interfacing with promenade planter and is subject to the planng design co-ordinaon with Promenade design
Table C- Tree Planng Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM)
SPREAD (MM)
DBH (MM) QTY
Eucalyptus tereticornis 5000 3000 75 4
Eucalyptus tereticornis 7000 4000 100 3
Sterculia lanceolata 4000 3000 100 4
Viburnum odoratissimum 3000 2000 75 2
nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
Table D- Large Shrub Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM) SPREAD (MM) QTY
Polyspora axillaris 2000 1000 17 Ligustrum sinense 2000 1000 18
nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
Table E- Climber Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM) SPACING (MM)
Campsis grandiflora 600 200 Ficus pumila 600 200 Epipremnum aureum 600 200 Lonicera japonica 600 200 Tristellateia australasiae 600 200 nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
Table F- Hydroseeding Seed Mix for Ground Floor SCIENTIFIC NAME RATE
Imperata cylindrica Varmajor 20 GSQM
Celosia argentea 5 GSQM Kalimeris indica 5 GSQM native species
4 POST PLANTING CARE PLAN
411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX A PLANTING PLANS AND SCHEDULE noitpircseD -on gniwarD
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 1 of 2) 3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 2 of 2) 3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 1 of 4) 3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 2 of 4) 3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 3 of 4) 3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 4 of 4) 3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 3F Shrubs and Groundcovers Schedule 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 1 of 2) 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 2 of 2)
1
7
6
5
4
A B C D E F
SPACE ALL TREESAT LEAST 5mFROM BASE OF WALL
AHU AHU
+1270+1260
250mm SURFACE CHANNEL
CLIMBER PLANTINGON CSF FACADE
1100 (H)BALUSTRADE
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
LOJ
TRA
(ALT
ERNA
TE P
LANT
ING)
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
FUEL PIPERUNNING IN SOILMATCH LINE
REFER to INSERT A
MIN 2000
MIN 2000
GF - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Et(l) EUCALYPTUS TERETICORNIS 細葉桉 5000 3000 75 4
Et(h) EUCALYPTUS TERETICORNIS 細葉桉 7000 4000 100 3
Sla STERCULIA LANCEOLATA 假蘋婆 4000 3000 100 4
Pax POLYSPORA AXILLARIS 大頭茶 2000 1000 - 17 MULTI-TRUNK
Lsi LIGUSTRUM SINENSE 山指甲 2000 1000 75 18
Vod VIBURNUM ODORATISSIMUM 珊瑚樹 3000 2000 75 2
GF CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 60000 - 20000 1200 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 60000 - 20000 1800 4 SHOOTS PER PLANT
EPA EPIPREMNUM AUREUM 綠蘿 60000 - 20000 400 4 SHOOTS PER PLANT
LOJ LONICERA JAPONICA 忍冬 金銀花 60000 - 20000 72 4 SHOOTS PER PLANT
TRA TRISTELLATEIA AUSTRALASIAE 三星果 60000 - 20000 72 4 SHOOTS PER PLANT
CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED AS STATED
HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
Native Species
2
1
7
6
A
AT LEAST 5mFROM BASE OF WALL
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
PLANTING AREA TO BEDESIGNED BY THE PARK
PLANTING AREA TO BEDESIGNED BY THE PARK
MATCH LINE
REFER to INSERT A
MIN 2000
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBERALONG WALL
TREE
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-G
AM-L
AN-D
WG
-900
3-P0
0-L0
00-W
S4
CAG
FIP
(ALTERNATE PLANTING)
SEDTRANSFER
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED SELF-CLINGING CLIMBER
PLANTING ON VERTICALBOUNDARY WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
EPA
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P 72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
retaW tlaS gnitsixEPumping Station
KRAP05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBBox
15P
A05P kraP gnicafretnI +M
N
04PM+
A93PB93P
FSCEDR
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 2)
3AXXX-GAM-LAN-DWG-9002-P01-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
1 100 SCALE BAR
0 25 5m
N KEY PLAN
MAIN PLAN
INSERT A
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
031
220
19 9
40
40 A
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
1
7
6
5
4
3
2
G H J K L M
CAG
FIP
(ALTERNATE PLANTING)
SELF-CLINGING CLIMBER
PLANTING ON VERTICAL
BOUNDARY WALL
ARTIST
SQUARE
CSF
STAFF
ENTRANCE
ST
PR
LT-51
LT-53
LT-52
ART
LIFT
ST
PR
MEP
UP
UP
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
STREET FIRE HYDRANT
P39B BOUNDARY
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
EPA
P39B BOUNDARY
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-G
AM
-L
AN
-D
WG
-9
00
2-P
00
-L
00
0-W
S4
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBER
ALONG WALL
PROPRIETARY WIRE
GREEN WALL SYSTEM
TREE
P39B HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
P39B CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 600 - 200 700 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 600 - 200 630 4 SHOOTS PER PLANT
ALL CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED
Native Species
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFSFIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Medium
Theatre I
Medium
Theatre IICCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega Perfo
rmance V
enue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREES
AND SHRUBS PLAN
(SHEET 2 of 2)
3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01
11102019 101916 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
1
2
3
4
5
6
7
7
HR
FS3-1-005B
PA250 NOS
CAP750 NOS
AW700 NOS
CAS650 NOS
HP250 NOS
IC350 NOS
HS50 NOS
IC350 NOS
AZ250 NOS
HS350 NOS
SR490 NOS
HP150 NOS
HP950 NOS
HP250 NOS
SR300 NOS
CAS200 NOS
CA515 NOS
JG350
HS250 NOS
HP450 NOS
HS350 NOS
CAS450 NOS
JG150 NOS
AW200 NOS
CAP700 NOS
SR600 NOS
AZ350 NOS PA
650 NOS
JG1250 NOS
CAS350 NOS
CA450 NOS
SR500 NOS
DFL150 NOS
ABO150 NOS
HP450 NOS
HS400 NOS
HS150 NOS
SR250 NOS
HP400 NOS
AZ50 NOS
AZ350 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
AZ750 NOS
CAP500 NOS
CA150 NOS
FFS30 NOS
AZ200 NOS
HP300 NOS
CAP400 NOS
DFL100 NOS
500500
500
500
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 4)
3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
900mm (H) HS SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
1100mm (H) HP SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
^
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
31
04 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
2
3
4
5
6
7
HR
FS3-1-005A
FS3-1-005BHR
ST-76
HP400 NOS
AZ50 NOS
CAS700 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
CAP500 NOS
AW350 NOS
HP300 NOS
SR550 NOS
HS650 NOS
DFL150 NOS CAP
350 NOS DFL220 NOS
SR250 NOS
AZ250 NOS
SR520 NOS
HP350 NOS SR
340 NOS
AZ600 NOS JG
450 NOS HS250 NOS
ABG100 NOS
AZ250 NOS
SR650 NOS
JG900 NOS
PA200 NOS
HP250 NOS
AW850 NOS
CAS850 NOS
CAP800 NOS
CAS850 NOS
SR350 NOS
PA500 NOS
HP300 NOS
500
500
0
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
5398
5085
5258
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 2 of 4)
3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
29
41 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
B C E FDA
HR
11
FS3-1-005B
CFA180 NOS
CFC250 NOS
CFC150 NOS
CFB450 NOS
CFA250 NOS
JG150 NOS
DE350 NOS
OJ3050 NOS
DE350 NOS
ZCI2100 NOS
CAS400 NOS
CGY50 NOS
CGY250 NOS
CFC250 NOS
CFA550 NOS
TS60 NOS
CGY250 NOS
CFT150 NOS
ABO80 NOS
CFT80 NOS
ABO60 NOS
JG150 NOS
CFC100 NOS
CFA150 NOS
CGY250 NOS
CFA250 NOS
CFT500 NOS
CFA300 NOS
YGC150 NOS
CAS150 NOS
CT200 NOS
TS50 NOS
CFC150 NOS
CGY350 NOS
CFB350 NOS
ZCA2000 NOS
DE550 NOS
ZCI1450 NOS
DE100 NOS
ZCA1200 NOS ZCI
4400 NOS
DE550 NOS
ZCI4250 NOS
JG150 NOS
CFC50 NOS
CGY500 NOS
CFB200 NOS
CFA450 NOS
BC200 NOS
CFA392 NOS
FFS25 NOS
CGY600 NOS
CAS250 NOS
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
BC350 NOS
CFC800 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
ZCI3550 NOSOJ
250 NOSZCI
1350 NOSDE
450 NOS
ZCA2250 NOS
NCA150 NOS
150 NOS
CGY450 NOS
CFB50 NOS
CFA300 NOS
CAS200 NOSCGY
250 NOSCFA520 NOS
FFS60 NOS
BC100 NOS
CTSON 051
500
500
500
500
500
500
500
500
CAS120 NOS
TOP VENT OPENING
900 x 900ACCESSHATCH
900 x 900ACCESSHATCH
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
NOTES
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 3 of 4)
3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
^
^
^
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
35
44 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
HR
11
FS3-1-005A
FS3-1-005BHR
ST-76
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
NCA150 NOS
CFA100 NOS
CVI150 NOS
CFT350 NOS
JG150 NOS ZCI
2000 NOS
NCA60 NOS
ZCA2300 NOS
CFC150 NOS
JG100 NOS
ZCA1250 NOS
ZCI2500 NOS
NCA250 NOS
ZCA400 NOS
CFT400 NOS
ZCI600 NOS
CT250 NOS
CFC650 NOS JG
110 NOS
CFC50 NOS
OJ1350 NOS
CFB160 NOS
CFA500 NOS
DE750 NOS
ZCA5050 NOS
OJ2650 NOS
ZCI3750 NOS
ZCA3850 NOS
CFT1150 NOS
CT450 NOS
CT250 NOSCAS
800 NOSJG250 NOS
CT950 NOS
CAS100 NOS
CGY350 NOS
CT350 NOS
CAS500 NOS
CFT200 NOS
CT150 NOS
OGY100 NOS
CFA550 NOS
CFC200 NOS
CVI150 NOS
FFS100 NOS
CFB150 NOS
JG200 NOS
ABG250 NOS
CFC750 NOS
CFA450 NOS
CFC300 NOS
CVI150 NOS
CFB100 NOS
TSC100 NOS
ZCA2000 NOS
CGY300 NOS
CFT1200 NOS
BC250 NOS
JG100 NOS
CFC60 NOS
CVI50 NOS
CFB100 NOS
CVI50 NOSCGY
100 NOS
CAS250 NOS
CGY300 NOS
CFA1000 NOS
CAS900 NOS
CT550 NOSCVI
550 NOS
CFT400 NOS
CGY450 NOS
CFB50 NOS
BC100 NOS
CFA900 NOS
CFT350 NOS
CVI450 NOS
CT650 NOS
CVI250 NOS
4201
700
0
6756NCA60 NOS
TOP VENT OPENING
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 4 of 4)
3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^ ^
900mm (H) CT SURROUNDTHE DOG HOUSE FORSCREENING OFF
^
^
^
^
^
^
900mm (H) CFC SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
52
08 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
modulations of colour as well as the formal architecture of their leaves and flowers These species are arranged into vegetative clans led by a majority species and supported by a set of supporting species Dense mass-planting of a restrained planting palette in wide swaths will generate a subtle graphic field condition legible from upper stories of the building as well as on the roof itself
322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cadence of vegetation that modulates in section as well as plan while still preserving sight lines across and over the flora towards the Hong Kong skyline and beyond This overall height scheme is altered in specific locations to provide for moments of greater insularity or exposure
323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles of the individual plants are to be left visible seedpods dried blooms etc are to be left on the plants nuancing the formal qualities of the scheme throughout the year
324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-LAN-DWG-0524-P00-L003-WS4 and 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4 in the Appendix A
325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
1 The site area of this project is approx 22966 m2 The green coverage is 9002774m2 22966m2 which is approximately 39
Table A ndash Greening Coverage Summary Table
Location Green Coverage (m2) Remarks
Green area at pedestrian zone
B1 Floor 297940 (GP3) Refer to Appendix C
Ground Floor 989065 (GP1 + GP2) Refer to Appendix C
Vertical Greenery at pedestrian zone
Green Area at Pedestrian zone
500556 (VP1 + VP2) Refer to Appendix C
Green area at 3 Floor Terrace Zone
3 Floor podium roof 7215213 (GT1-GT18) Refer to Appendix C
Total Greenery Area 9002774
Total Greenery Area Percentage
~ 391 Comply with the Master Register greenery
requirement 2
2 Based on the Approved West Kowloon Cultural District Development Plan No SK20WKCD2 there is a requirement for the provision of minimum green coverage of 30 and 60 for the whole WKCD and the Park respecvely
Table B- Tree Planng Schedule for B1 Floor
SCIENTIFIC NAME HEIGHT
(MM)
SPREAD (MM) DBH (MM) QTY
Terminalia mantaly 5000 3000 100 3 please refer to Drawing No 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 and 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 in Appendix A These 3 trees planng is planted at a planter interfacing with promenade planter and is subject to the planng design co-ordinaon with Promenade design
Table C- Tree Planng Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM)
SPREAD (MM)
DBH (MM) QTY
Eucalyptus tereticornis 5000 3000 75 4
Eucalyptus tereticornis 7000 4000 100 3
Sterculia lanceolata 4000 3000 100 4
Viburnum odoratissimum 3000 2000 75 2
nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
Table D- Large Shrub Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM) SPREAD (MM) QTY
Polyspora axillaris 2000 1000 17 Ligustrum sinense 2000 1000 18
nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
Table E- Climber Schedule for Ground Floor
SCIENTIFIC NAME HEIGHT (MM) SPACING (MM)
Campsis grandiflora 600 200 Ficus pumila 600 200 Epipremnum aureum 600 200 Lonicera japonica 600 200 Tristellateia australasiae 600 200 nave species please refer to Drawing No 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4 and 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4 in Appendix A
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
Table F- Hydroseeding Seed Mix for Ground Floor SCIENTIFIC NAME RATE
Imperata cylindrica Varmajor 20 GSQM
Celosia argentea 5 GSQM Kalimeris indica 5 GSQM native species
4 POST PLANTING CARE PLAN
411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX A PLANTING PLANS AND SCHEDULE noitpircseD -on gniwarD
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 1 of 2) 3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 2 of 2) 3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 1 of 4) 3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 2 of 4) 3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 3 of 4) 3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 4 of 4) 3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 3F Shrubs and Groundcovers Schedule 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 1 of 2) 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 2 of 2)
1
7
6
5
4
A B C D E F
SPACE ALL TREESAT LEAST 5mFROM BASE OF WALL
AHU AHU
+1270+1260
250mm SURFACE CHANNEL
CLIMBER PLANTINGON CSF FACADE
1100 (H)BALUSTRADE
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
LOJ
TRA
(ALT
ERNA
TE P
LANT
ING)
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
FUEL PIPERUNNING IN SOILMATCH LINE
REFER to INSERT A
MIN 2000
MIN 2000
GF - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Et(l) EUCALYPTUS TERETICORNIS 細葉桉 5000 3000 75 4
Et(h) EUCALYPTUS TERETICORNIS 細葉桉 7000 4000 100 3
Sla STERCULIA LANCEOLATA 假蘋婆 4000 3000 100 4
Pax POLYSPORA AXILLARIS 大頭茶 2000 1000 - 17 MULTI-TRUNK
Lsi LIGUSTRUM SINENSE 山指甲 2000 1000 75 18
Vod VIBURNUM ODORATISSIMUM 珊瑚樹 3000 2000 75 2
GF CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 60000 - 20000 1200 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 60000 - 20000 1800 4 SHOOTS PER PLANT
EPA EPIPREMNUM AUREUM 綠蘿 60000 - 20000 400 4 SHOOTS PER PLANT
LOJ LONICERA JAPONICA 忍冬 金銀花 60000 - 20000 72 4 SHOOTS PER PLANT
TRA TRISTELLATEIA AUSTRALASIAE 三星果 60000 - 20000 72 4 SHOOTS PER PLANT
CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED AS STATED
HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
Native Species
2
1
7
6
A
AT LEAST 5mFROM BASE OF WALL
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
PLANTING AREA TO BEDESIGNED BY THE PARK
PLANTING AREA TO BEDESIGNED BY THE PARK
MATCH LINE
REFER to INSERT A
MIN 2000
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBERALONG WALL
TREE
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-G
AM-L
AN-D
WG
-900
3-P0
0-L0
00-W
S4
CAG
FIP
(ALTERNATE PLANTING)
SEDTRANSFER
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED SELF-CLINGING CLIMBER
PLANTING ON VERTICALBOUNDARY WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
EPA
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P 72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
retaW tlaS gnitsixEPumping Station
KRAP05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBBox
15P
A05P kraP gnicafretnI +M
N
04PM+
A93PB93P
FSCEDR
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 2)
3AXXX-GAM-LAN-DWG-9002-P01-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
1 100 SCALE BAR
0 25 5m
N KEY PLAN
MAIN PLAN
INSERT A
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
031
220
19 9
40
40 A
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
1
7
6
5
4
3
2
G H J K L M
CAG
FIP
(ALTERNATE PLANTING)
SELF-CLINGING CLIMBER
PLANTING ON VERTICAL
BOUNDARY WALL
ARTIST
SQUARE
CSF
STAFF
ENTRANCE
ST
PR
LT-51
LT-53
LT-52
ART
LIFT
ST
PR
MEP
UP
UP
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
STREET FIRE HYDRANT
P39B BOUNDARY
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
EPA
P39B BOUNDARY
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-G
AM
-L
AN
-D
WG
-9
00
2-P
00
-L
00
0-W
S4
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBER
ALONG WALL
PROPRIETARY WIRE
GREEN WALL SYSTEM
TREE
P39B HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
P39B CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 600 - 200 700 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 600 - 200 630 4 SHOOTS PER PLANT
ALL CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED
Native Species
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFSFIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Medium
Theatre I
Medium
Theatre IICCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega Perfo
rmance V
enue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREES
AND SHRUBS PLAN
(SHEET 2 of 2)
3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01
11102019 101916 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
1
2
3
4
5
6
7
7
HR
FS3-1-005B
PA250 NOS
CAP750 NOS
AW700 NOS
CAS650 NOS
HP250 NOS
IC350 NOS
HS50 NOS
IC350 NOS
AZ250 NOS
HS350 NOS
SR490 NOS
HP150 NOS
HP950 NOS
HP250 NOS
SR300 NOS
CAS200 NOS
CA515 NOS
JG350
HS250 NOS
HP450 NOS
HS350 NOS
CAS450 NOS
JG150 NOS
AW200 NOS
CAP700 NOS
SR600 NOS
AZ350 NOS PA
650 NOS
JG1250 NOS
CAS350 NOS
CA450 NOS
SR500 NOS
DFL150 NOS
ABO150 NOS
HP450 NOS
HS400 NOS
HS150 NOS
SR250 NOS
HP400 NOS
AZ50 NOS
AZ350 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
AZ750 NOS
CAP500 NOS
CA150 NOS
FFS30 NOS
AZ200 NOS
HP300 NOS
CAP400 NOS
DFL100 NOS
500500
500
500
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 4)
3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
900mm (H) HS SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
1100mm (H) HP SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
^
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
31
04 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
2
3
4
5
6
7
HR
FS3-1-005A
FS3-1-005BHR
ST-76
HP400 NOS
AZ50 NOS
CAS700 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
CAP500 NOS
AW350 NOS
HP300 NOS
SR550 NOS
HS650 NOS
DFL150 NOS CAP
350 NOS DFL220 NOS
SR250 NOS
AZ250 NOS
SR520 NOS
HP350 NOS SR
340 NOS
AZ600 NOS JG
450 NOS HS250 NOS
ABG100 NOS
AZ250 NOS
SR650 NOS
JG900 NOS
PA200 NOS
HP250 NOS
AW850 NOS
CAS850 NOS
CAP800 NOS
CAS850 NOS
SR350 NOS
PA500 NOS
HP300 NOS
500
500
0
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
5398
5085
5258
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 2 of 4)
3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
29
41 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
B C E FDA
HR
11
FS3-1-005B
CFA180 NOS
CFC250 NOS
CFC150 NOS
CFB450 NOS
CFA250 NOS
JG150 NOS
DE350 NOS
OJ3050 NOS
DE350 NOS
ZCI2100 NOS
CAS400 NOS
CGY50 NOS
CGY250 NOS
CFC250 NOS
CFA550 NOS
TS60 NOS
CGY250 NOS
CFT150 NOS
ABO80 NOS
CFT80 NOS
ABO60 NOS
JG150 NOS
CFC100 NOS
CFA150 NOS
CGY250 NOS
CFA250 NOS
CFT500 NOS
CFA300 NOS
YGC150 NOS
CAS150 NOS
CT200 NOS
TS50 NOS
CFC150 NOS
CGY350 NOS
CFB350 NOS
ZCA2000 NOS
DE550 NOS
ZCI1450 NOS
DE100 NOS
ZCA1200 NOS ZCI
4400 NOS
DE550 NOS
ZCI4250 NOS
JG150 NOS
CFC50 NOS
CGY500 NOS
CFB200 NOS
CFA450 NOS
BC200 NOS
CFA392 NOS
FFS25 NOS
CGY600 NOS
CAS250 NOS
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
BC350 NOS
CFC800 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
ZCI3550 NOSOJ
250 NOSZCI
1350 NOSDE
450 NOS
ZCA2250 NOS
NCA150 NOS
150 NOS
CGY450 NOS
CFB50 NOS
CFA300 NOS
CAS200 NOSCGY
250 NOSCFA520 NOS
FFS60 NOS
BC100 NOS
CTSON 051
500
500
500
500
500
500
500
500
CAS120 NOS
TOP VENT OPENING
900 x 900ACCESSHATCH
900 x 900ACCESSHATCH
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
NOTES
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 3 of 4)
3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
^
^
^
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
35
44 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
HR
11
FS3-1-005A
FS3-1-005BHR
ST-76
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
NCA150 NOS
CFA100 NOS
CVI150 NOS
CFT350 NOS
JG150 NOS ZCI
2000 NOS
NCA60 NOS
ZCA2300 NOS
CFC150 NOS
JG100 NOS
ZCA1250 NOS
ZCI2500 NOS
NCA250 NOS
ZCA400 NOS
CFT400 NOS
ZCI600 NOS
CT250 NOS
CFC650 NOS JG
110 NOS
CFC50 NOS
OJ1350 NOS
CFB160 NOS
CFA500 NOS
DE750 NOS
ZCA5050 NOS
OJ2650 NOS
ZCI3750 NOS
ZCA3850 NOS
CFT1150 NOS
CT450 NOS
CT250 NOSCAS
800 NOSJG250 NOS
CT950 NOS
CAS100 NOS
CGY350 NOS
CT350 NOS
CAS500 NOS
CFT200 NOS
CT150 NOS
OGY100 NOS
CFA550 NOS
CFC200 NOS
CVI150 NOS
FFS100 NOS
CFB150 NOS
JG200 NOS
ABG250 NOS
CFC750 NOS
CFA450 NOS
CFC300 NOS
CVI150 NOS
CFB100 NOS
TSC100 NOS
ZCA2000 NOS
CGY300 NOS
CFT1200 NOS
BC250 NOS
JG100 NOS
CFC60 NOS
CVI50 NOS
CFB100 NOS
CVI50 NOSCGY
100 NOS
CAS250 NOS
CGY300 NOS
CFA1000 NOS
CAS900 NOS
CT550 NOSCVI
550 NOS
CFT400 NOS
CGY450 NOS
CFB50 NOS
BC100 NOS
CFA900 NOS
CFT350 NOS
CVI450 NOS
CT650 NOS
CVI250 NOS
4201
700
0
6756NCA60 NOS
TOP VENT OPENING
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 4 of 4)
3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^ ^
900mm (H) CT SURROUNDTHE DOG HOUSE FORSCREENING OFF
^
^
^
^
^
^
900mm (H) CFC SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
52
08 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
Table F- Hydroseeding Seed Mix for Ground Floor SCIENTIFIC NAME RATE
Imperata cylindrica Varmajor 20 GSQM
Celosia argentea 5 GSQM Kalimeris indica 5 GSQM native species
4 POST PLANTING CARE PLAN
411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX A PLANTING PLANS AND SCHEDULE noitpircseD -on gniwarD
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 1 of 2) 3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 2 of 2) 3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 1 of 4) 3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 2 of 4) 3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 3 of 4) 3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 4 of 4) 3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 3F Shrubs and Groundcovers Schedule 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 1 of 2) 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 2 of 2)
1
7
6
5
4
A B C D E F
SPACE ALL TREESAT LEAST 5mFROM BASE OF WALL
AHU AHU
+1270+1260
250mm SURFACE CHANNEL
CLIMBER PLANTINGON CSF FACADE
1100 (H)BALUSTRADE
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
LOJ
TRA
(ALT
ERNA
TE P
LANT
ING)
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
FUEL PIPERUNNING IN SOILMATCH LINE
REFER to INSERT A
MIN 2000
MIN 2000
GF - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Et(l) EUCALYPTUS TERETICORNIS 細葉桉 5000 3000 75 4
Et(h) EUCALYPTUS TERETICORNIS 細葉桉 7000 4000 100 3
Sla STERCULIA LANCEOLATA 假蘋婆 4000 3000 100 4
Pax POLYSPORA AXILLARIS 大頭茶 2000 1000 - 17 MULTI-TRUNK
Lsi LIGUSTRUM SINENSE 山指甲 2000 1000 75 18
Vod VIBURNUM ODORATISSIMUM 珊瑚樹 3000 2000 75 2
GF CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 60000 - 20000 1200 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 60000 - 20000 1800 4 SHOOTS PER PLANT
EPA EPIPREMNUM AUREUM 綠蘿 60000 - 20000 400 4 SHOOTS PER PLANT
LOJ LONICERA JAPONICA 忍冬 金銀花 60000 - 20000 72 4 SHOOTS PER PLANT
TRA TRISTELLATEIA AUSTRALASIAE 三星果 60000 - 20000 72 4 SHOOTS PER PLANT
CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED AS STATED
HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
Native Species
2
1
7
6
A
AT LEAST 5mFROM BASE OF WALL
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
PLANTING AREA TO BEDESIGNED BY THE PARK
PLANTING AREA TO BEDESIGNED BY THE PARK
MATCH LINE
REFER to INSERT A
MIN 2000
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBERALONG WALL
TREE
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-G
AM-L
AN-D
WG
-900
3-P0
0-L0
00-W
S4
CAG
FIP
(ALTERNATE PLANTING)
SEDTRANSFER
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED SELF-CLINGING CLIMBER
PLANTING ON VERTICALBOUNDARY WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
EPA
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P 72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
retaW tlaS gnitsixEPumping Station
KRAP05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBBox
15P
A05P kraP gnicafretnI +M
N
04PM+
A93PB93P
FSCEDR
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 2)
3AXXX-GAM-LAN-DWG-9002-P01-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
1 100 SCALE BAR
0 25 5m
N KEY PLAN
MAIN PLAN
INSERT A
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
031
220
19 9
40
40 A
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
1
7
6
5
4
3
2
G H J K L M
CAG
FIP
(ALTERNATE PLANTING)
SELF-CLINGING CLIMBER
PLANTING ON VERTICAL
BOUNDARY WALL
ARTIST
SQUARE
CSF
STAFF
ENTRANCE
ST
PR
LT-51
LT-53
LT-52
ART
LIFT
ST
PR
MEP
UP
UP
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
STREET FIRE HYDRANT
P39B BOUNDARY
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
EPA
P39B BOUNDARY
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-G
AM
-L
AN
-D
WG
-9
00
2-P
00
-L
00
0-W
S4
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBER
ALONG WALL
PROPRIETARY WIRE
GREEN WALL SYSTEM
TREE
P39B HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
P39B CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 600 - 200 700 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 600 - 200 630 4 SHOOTS PER PLANT
ALL CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED
Native Species
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFSFIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Medium
Theatre I
Medium
Theatre IICCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega Perfo
rmance V
enue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREES
AND SHRUBS PLAN
(SHEET 2 of 2)
3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01
11102019 101916 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
1
2
3
4
5
6
7
7
HR
FS3-1-005B
PA250 NOS
CAP750 NOS
AW700 NOS
CAS650 NOS
HP250 NOS
IC350 NOS
HS50 NOS
IC350 NOS
AZ250 NOS
HS350 NOS
SR490 NOS
HP150 NOS
HP950 NOS
HP250 NOS
SR300 NOS
CAS200 NOS
CA515 NOS
JG350
HS250 NOS
HP450 NOS
HS350 NOS
CAS450 NOS
JG150 NOS
AW200 NOS
CAP700 NOS
SR600 NOS
AZ350 NOS PA
650 NOS
JG1250 NOS
CAS350 NOS
CA450 NOS
SR500 NOS
DFL150 NOS
ABO150 NOS
HP450 NOS
HS400 NOS
HS150 NOS
SR250 NOS
HP400 NOS
AZ50 NOS
AZ350 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
AZ750 NOS
CAP500 NOS
CA150 NOS
FFS30 NOS
AZ200 NOS
HP300 NOS
CAP400 NOS
DFL100 NOS
500500
500
500
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 4)
3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
900mm (H) HS SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
1100mm (H) HP SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
^
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
31
04 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
2
3
4
5
6
7
HR
FS3-1-005A
FS3-1-005BHR
ST-76
HP400 NOS
AZ50 NOS
CAS700 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
CAP500 NOS
AW350 NOS
HP300 NOS
SR550 NOS
HS650 NOS
DFL150 NOS CAP
350 NOS DFL220 NOS
SR250 NOS
AZ250 NOS
SR520 NOS
HP350 NOS SR
340 NOS
AZ600 NOS JG
450 NOS HS250 NOS
ABG100 NOS
AZ250 NOS
SR650 NOS
JG900 NOS
PA200 NOS
HP250 NOS
AW850 NOS
CAS850 NOS
CAP800 NOS
CAS850 NOS
SR350 NOS
PA500 NOS
HP300 NOS
500
500
0
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
5398
5085
5258
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 2 of 4)
3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
29
41 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
B C E FDA
HR
11
FS3-1-005B
CFA180 NOS
CFC250 NOS
CFC150 NOS
CFB450 NOS
CFA250 NOS
JG150 NOS
DE350 NOS
OJ3050 NOS
DE350 NOS
ZCI2100 NOS
CAS400 NOS
CGY50 NOS
CGY250 NOS
CFC250 NOS
CFA550 NOS
TS60 NOS
CGY250 NOS
CFT150 NOS
ABO80 NOS
CFT80 NOS
ABO60 NOS
JG150 NOS
CFC100 NOS
CFA150 NOS
CGY250 NOS
CFA250 NOS
CFT500 NOS
CFA300 NOS
YGC150 NOS
CAS150 NOS
CT200 NOS
TS50 NOS
CFC150 NOS
CGY350 NOS
CFB350 NOS
ZCA2000 NOS
DE550 NOS
ZCI1450 NOS
DE100 NOS
ZCA1200 NOS ZCI
4400 NOS
DE550 NOS
ZCI4250 NOS
JG150 NOS
CFC50 NOS
CGY500 NOS
CFB200 NOS
CFA450 NOS
BC200 NOS
CFA392 NOS
FFS25 NOS
CGY600 NOS
CAS250 NOS
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
BC350 NOS
CFC800 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
ZCI3550 NOSOJ
250 NOSZCI
1350 NOSDE
450 NOS
ZCA2250 NOS
NCA150 NOS
150 NOS
CGY450 NOS
CFB50 NOS
CFA300 NOS
CAS200 NOSCGY
250 NOSCFA520 NOS
FFS60 NOS
BC100 NOS
CTSON 051
500
500
500
500
500
500
500
500
CAS120 NOS
TOP VENT OPENING
900 x 900ACCESSHATCH
900 x 900ACCESSHATCH
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
NOTES
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 3 of 4)
3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
^
^
^
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
35
44 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
HR
11
FS3-1-005A
FS3-1-005BHR
ST-76
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
NCA150 NOS
CFA100 NOS
CVI150 NOS
CFT350 NOS
JG150 NOS ZCI
2000 NOS
NCA60 NOS
ZCA2300 NOS
CFC150 NOS
JG100 NOS
ZCA1250 NOS
ZCI2500 NOS
NCA250 NOS
ZCA400 NOS
CFT400 NOS
ZCI600 NOS
CT250 NOS
CFC650 NOS JG
110 NOS
CFC50 NOS
OJ1350 NOS
CFB160 NOS
CFA500 NOS
DE750 NOS
ZCA5050 NOS
OJ2650 NOS
ZCI3750 NOS
ZCA3850 NOS
CFT1150 NOS
CT450 NOS
CT250 NOSCAS
800 NOSJG250 NOS
CT950 NOS
CAS100 NOS
CGY350 NOS
CT350 NOS
CAS500 NOS
CFT200 NOS
CT150 NOS
OGY100 NOS
CFA550 NOS
CFC200 NOS
CVI150 NOS
FFS100 NOS
CFB150 NOS
JG200 NOS
ABG250 NOS
CFC750 NOS
CFA450 NOS
CFC300 NOS
CVI150 NOS
CFB100 NOS
TSC100 NOS
ZCA2000 NOS
CGY300 NOS
CFT1200 NOS
BC250 NOS
JG100 NOS
CFC60 NOS
CVI50 NOS
CFB100 NOS
CVI50 NOSCGY
100 NOS
CAS250 NOS
CGY300 NOS
CFA1000 NOS
CAS900 NOS
CT550 NOSCVI
550 NOS
CFT400 NOS
CGY450 NOS
CFB50 NOS
BC100 NOS
CFA900 NOS
CFT350 NOS
CVI450 NOS
CT650 NOS
CVI250 NOS
4201
700
0
6756NCA60 NOS
TOP VENT OPENING
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 4 of 4)
3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^ ^
900mm (H) CT SURROUNDTHE DOG HOUSE FORSCREENING OFF
^
^
^
^
^
^
900mm (H) CFC SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
52
08 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX A PLANTING PLANS AND SCHEDULE noitpircseD -on gniwarD
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 1 of 2) 3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 GF Landscape Trees and Shrubs Plan (Sheet 2 of 2) 3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 1 of 4) 3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 2 of 4) 3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 3 of 4) 3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 3F Landscape Trees and Shrubs Plan (Sheet 4 of 4) 3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 3F Shrubs and Groundcovers Schedule 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 1 of 2) 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4 B1F Landscape Tree and Shrubs Plan (Sheet 2 of 2)
1
7
6
5
4
A B C D E F
SPACE ALL TREESAT LEAST 5mFROM BASE OF WALL
AHU AHU
+1270+1260
250mm SURFACE CHANNEL
CLIMBER PLANTINGON CSF FACADE
1100 (H)BALUSTRADE
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
LOJ
TRA
(ALT
ERNA
TE P
LANT
ING)
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
FUEL PIPERUNNING IN SOILMATCH LINE
REFER to INSERT A
MIN 2000
MIN 2000
GF - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Et(l) EUCALYPTUS TERETICORNIS 細葉桉 5000 3000 75 4
Et(h) EUCALYPTUS TERETICORNIS 細葉桉 7000 4000 100 3
Sla STERCULIA LANCEOLATA 假蘋婆 4000 3000 100 4
Pax POLYSPORA AXILLARIS 大頭茶 2000 1000 - 17 MULTI-TRUNK
Lsi LIGUSTRUM SINENSE 山指甲 2000 1000 75 18
Vod VIBURNUM ODORATISSIMUM 珊瑚樹 3000 2000 75 2
GF CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 60000 - 20000 1200 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 60000 - 20000 1800 4 SHOOTS PER PLANT
EPA EPIPREMNUM AUREUM 綠蘿 60000 - 20000 400 4 SHOOTS PER PLANT
LOJ LONICERA JAPONICA 忍冬 金銀花 60000 - 20000 72 4 SHOOTS PER PLANT
TRA TRISTELLATEIA AUSTRALASIAE 三星果 60000 - 20000 72 4 SHOOTS PER PLANT
CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED AS STATED
HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
Native Species
2
1
7
6
A
AT LEAST 5mFROM BASE OF WALL
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
PLANTING AREA TO BEDESIGNED BY THE PARK
PLANTING AREA TO BEDESIGNED BY THE PARK
MATCH LINE
REFER to INSERT A
MIN 2000
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBERALONG WALL
TREE
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-G
AM-L
AN-D
WG
-900
3-P0
0-L0
00-W
S4
CAG
FIP
(ALTERNATE PLANTING)
SEDTRANSFER
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED SELF-CLINGING CLIMBER
PLANTING ON VERTICALBOUNDARY WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
EPA
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P 72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
retaW tlaS gnitsixEPumping Station
KRAP05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBBox
15P
A05P kraP gnicafretnI +M
N
04PM+
A93PB93P
FSCEDR
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 2)
3AXXX-GAM-LAN-DWG-9002-P01-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
1 100 SCALE BAR
0 25 5m
N KEY PLAN
MAIN PLAN
INSERT A
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
031
220
19 9
40
40 A
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
1
7
6
5
4
3
2
G H J K L M
CAG
FIP
(ALTERNATE PLANTING)
SELF-CLINGING CLIMBER
PLANTING ON VERTICAL
BOUNDARY WALL
ARTIST
SQUARE
CSF
STAFF
ENTRANCE
ST
PR
LT-51
LT-53
LT-52
ART
LIFT
ST
PR
MEP
UP
UP
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
STREET FIRE HYDRANT
P39B BOUNDARY
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
EPA
P39B BOUNDARY
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-G
AM
-L
AN
-D
WG
-9
00
2-P
00
-L
00
0-W
S4
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBER
ALONG WALL
PROPRIETARY WIRE
GREEN WALL SYSTEM
TREE
P39B HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
P39B CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 600 - 200 700 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 600 - 200 630 4 SHOOTS PER PLANT
ALL CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED
Native Species
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFSFIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Medium
Theatre I
Medium
Theatre IICCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega Perfo
rmance V
enue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREES
AND SHRUBS PLAN
(SHEET 2 of 2)
3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01
11102019 101916 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
1
2
3
4
5
6
7
7
HR
FS3-1-005B
PA250 NOS
CAP750 NOS
AW700 NOS
CAS650 NOS
HP250 NOS
IC350 NOS
HS50 NOS
IC350 NOS
AZ250 NOS
HS350 NOS
SR490 NOS
HP150 NOS
HP950 NOS
HP250 NOS
SR300 NOS
CAS200 NOS
CA515 NOS
JG350
HS250 NOS
HP450 NOS
HS350 NOS
CAS450 NOS
JG150 NOS
AW200 NOS
CAP700 NOS
SR600 NOS
AZ350 NOS PA
650 NOS
JG1250 NOS
CAS350 NOS
CA450 NOS
SR500 NOS
DFL150 NOS
ABO150 NOS
HP450 NOS
HS400 NOS
HS150 NOS
SR250 NOS
HP400 NOS
AZ50 NOS
AZ350 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
AZ750 NOS
CAP500 NOS
CA150 NOS
FFS30 NOS
AZ200 NOS
HP300 NOS
CAP400 NOS
DFL100 NOS
500500
500
500
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 4)
3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
900mm (H) HS SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
1100mm (H) HP SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
^
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
31
04 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
2
3
4
5
6
7
HR
FS3-1-005A
FS3-1-005BHR
ST-76
HP400 NOS
AZ50 NOS
CAS700 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
CAP500 NOS
AW350 NOS
HP300 NOS
SR550 NOS
HS650 NOS
DFL150 NOS CAP
350 NOS DFL220 NOS
SR250 NOS
AZ250 NOS
SR520 NOS
HP350 NOS SR
340 NOS
AZ600 NOS JG
450 NOS HS250 NOS
ABG100 NOS
AZ250 NOS
SR650 NOS
JG900 NOS
PA200 NOS
HP250 NOS
AW850 NOS
CAS850 NOS
CAP800 NOS
CAS850 NOS
SR350 NOS
PA500 NOS
HP300 NOS
500
500
0
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
5398
5085
5258
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 2 of 4)
3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
29
41 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
B C E FDA
HR
11
FS3-1-005B
CFA180 NOS
CFC250 NOS
CFC150 NOS
CFB450 NOS
CFA250 NOS
JG150 NOS
DE350 NOS
OJ3050 NOS
DE350 NOS
ZCI2100 NOS
CAS400 NOS
CGY50 NOS
CGY250 NOS
CFC250 NOS
CFA550 NOS
TS60 NOS
CGY250 NOS
CFT150 NOS
ABO80 NOS
CFT80 NOS
ABO60 NOS
JG150 NOS
CFC100 NOS
CFA150 NOS
CGY250 NOS
CFA250 NOS
CFT500 NOS
CFA300 NOS
YGC150 NOS
CAS150 NOS
CT200 NOS
TS50 NOS
CFC150 NOS
CGY350 NOS
CFB350 NOS
ZCA2000 NOS
DE550 NOS
ZCI1450 NOS
DE100 NOS
ZCA1200 NOS ZCI
4400 NOS
DE550 NOS
ZCI4250 NOS
JG150 NOS
CFC50 NOS
CGY500 NOS
CFB200 NOS
CFA450 NOS
BC200 NOS
CFA392 NOS
FFS25 NOS
CGY600 NOS
CAS250 NOS
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
BC350 NOS
CFC800 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
ZCI3550 NOSOJ
250 NOSZCI
1350 NOSDE
450 NOS
ZCA2250 NOS
NCA150 NOS
150 NOS
CGY450 NOS
CFB50 NOS
CFA300 NOS
CAS200 NOSCGY
250 NOSCFA520 NOS
FFS60 NOS
BC100 NOS
CTSON 051
500
500
500
500
500
500
500
500
CAS120 NOS
TOP VENT OPENING
900 x 900ACCESSHATCH
900 x 900ACCESSHATCH
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
NOTES
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 3 of 4)
3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
^
^
^
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
35
44 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
HR
11
FS3-1-005A
FS3-1-005BHR
ST-76
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
NCA150 NOS
CFA100 NOS
CVI150 NOS
CFT350 NOS
JG150 NOS ZCI
2000 NOS
NCA60 NOS
ZCA2300 NOS
CFC150 NOS
JG100 NOS
ZCA1250 NOS
ZCI2500 NOS
NCA250 NOS
ZCA400 NOS
CFT400 NOS
ZCI600 NOS
CT250 NOS
CFC650 NOS JG
110 NOS
CFC50 NOS
OJ1350 NOS
CFB160 NOS
CFA500 NOS
DE750 NOS
ZCA5050 NOS
OJ2650 NOS
ZCI3750 NOS
ZCA3850 NOS
CFT1150 NOS
CT450 NOS
CT250 NOSCAS
800 NOSJG250 NOS
CT950 NOS
CAS100 NOS
CGY350 NOS
CT350 NOS
CAS500 NOS
CFT200 NOS
CT150 NOS
OGY100 NOS
CFA550 NOS
CFC200 NOS
CVI150 NOS
FFS100 NOS
CFB150 NOS
JG200 NOS
ABG250 NOS
CFC750 NOS
CFA450 NOS
CFC300 NOS
CVI150 NOS
CFB100 NOS
TSC100 NOS
ZCA2000 NOS
CGY300 NOS
CFT1200 NOS
BC250 NOS
JG100 NOS
CFC60 NOS
CVI50 NOS
CFB100 NOS
CVI50 NOSCGY
100 NOS
CAS250 NOS
CGY300 NOS
CFA1000 NOS
CAS900 NOS
CT550 NOSCVI
550 NOS
CFT400 NOS
CGY450 NOS
CFB50 NOS
BC100 NOS
CFA900 NOS
CFT350 NOS
CVI450 NOS
CT650 NOS
CVI250 NOS
4201
700
0
6756NCA60 NOS
TOP VENT OPENING
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 4 of 4)
3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^ ^
900mm (H) CT SURROUNDTHE DOG HOUSE FORSCREENING OFF
^
^
^
^
^
^
900mm (H) CFC SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
52
08 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
1
7
6
5
4
A B C D E F
SPACE ALL TREESAT LEAST 5mFROM BASE OF WALL
AHU AHU
+1270+1260
250mm SURFACE CHANNEL
CLIMBER PLANTINGON CSF FACADE
1100 (H)BALUSTRADE
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
LOJ
TRA
(ALT
ERNA
TE P
LANT
ING)
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
FUEL PIPERUNNING IN SOILMATCH LINE
REFER to INSERT A
MIN 2000
MIN 2000
GF - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Et(l) EUCALYPTUS TERETICORNIS 細葉桉 5000 3000 75 4
Et(h) EUCALYPTUS TERETICORNIS 細葉桉 7000 4000 100 3
Sla STERCULIA LANCEOLATA 假蘋婆 4000 3000 100 4
Pax POLYSPORA AXILLARIS 大頭茶 2000 1000 - 17 MULTI-TRUNK
Lsi LIGUSTRUM SINENSE 山指甲 2000 1000 75 18
Vod VIBURNUM ODORATISSIMUM 珊瑚樹 3000 2000 75 2
GF CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 60000 - 20000 1200 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 60000 - 20000 1800 4 SHOOTS PER PLANT
EPA EPIPREMNUM AUREUM 綠蘿 60000 - 20000 400 4 SHOOTS PER PLANT
LOJ LONICERA JAPONICA 忍冬 金銀花 60000 - 20000 72 4 SHOOTS PER PLANT
TRA TRISTELLATEIA AUSTRALASIAE 三星果 60000 - 20000 72 4 SHOOTS PER PLANT
CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED AS STATED
HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
Native Species
2
1
7
6
A
AT LEAST 5mFROM BASE OF WALL
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
400mm (W) U
-CHANNEL WITH CAST IRON COVER (W G
RAVEL ON TOP)
CAG FIPALTERNATIVE PLANTING
TRAILING DOWN ON WALL
PLANTING AREA TO BEDESIGNED BY THE PARK
PLANTING AREA TO BEDESIGNED BY THE PARK
MATCH LINE
REFER to INSERT A
MIN 2000
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBERALONG WALL
TREE
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-G
AM-L
AN-D
WG
-900
3-P0
0-L0
00-W
S4
CAG
FIP
(ALTERNATE PLANTING)
SEDTRANSFER
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED SELF-CLINGING CLIMBER
PLANTING ON VERTICALBOUNDARY WALL
400mm WIDTHCLIMBER PLANTING AREADO NOT HYDROSEED
EPA
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P 72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
retaW tlaS gnitsixEPumping Station
KRAP05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBBox
15P
A05P kraP gnicafretnI +M
N
04PM+
A93PB93P
FSCEDR
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 2)
3AXXX-GAM-LAN-DWG-9002-P01-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
1 100 SCALE BAR
0 25 5m
N KEY PLAN
MAIN PLAN
INSERT A
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
031
220
19 9
40
40 A
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
1
7
6
5
4
3
2
G H J K L M
CAG
FIP
(ALTERNATE PLANTING)
SELF-CLINGING CLIMBER
PLANTING ON VERTICAL
BOUNDARY WALL
ARTIST
SQUARE
CSF
STAFF
ENTRANCE
ST
PR
LT-51
LT-53
LT-52
ART
LIFT
ST
PR
MEP
UP
UP
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
STREET FIRE HYDRANT
P39B BOUNDARY
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
EPA
P39B BOUNDARY
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-G
AM
-L
AN
-D
WG
-9
00
2-P
00
-L
00
0-W
S4
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBER
ALONG WALL
PROPRIETARY WIRE
GREEN WALL SYSTEM
TREE
P39B HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
P39B CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 600 - 200 700 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 600 - 200 630 4 SHOOTS PER PLANT
ALL CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED
Native Species
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFSFIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Medium
Theatre I
Medium
Theatre IICCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega Perfo
rmance V
enue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREES
AND SHRUBS PLAN
(SHEET 2 of 2)
3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01
11102019 101916 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
1
2
3
4
5
6
7
7
HR
FS3-1-005B
PA250 NOS
CAP750 NOS
AW700 NOS
CAS650 NOS
HP250 NOS
IC350 NOS
HS50 NOS
IC350 NOS
AZ250 NOS
HS350 NOS
SR490 NOS
HP150 NOS
HP950 NOS
HP250 NOS
SR300 NOS
CAS200 NOS
CA515 NOS
JG350
HS250 NOS
HP450 NOS
HS350 NOS
CAS450 NOS
JG150 NOS
AW200 NOS
CAP700 NOS
SR600 NOS
AZ350 NOS PA
650 NOS
JG1250 NOS
CAS350 NOS
CA450 NOS
SR500 NOS
DFL150 NOS
ABO150 NOS
HP450 NOS
HS400 NOS
HS150 NOS
SR250 NOS
HP400 NOS
AZ50 NOS
AZ350 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
AZ750 NOS
CAP500 NOS
CA150 NOS
FFS30 NOS
AZ200 NOS
HP300 NOS
CAP400 NOS
DFL100 NOS
500500
500
500
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 4)
3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
900mm (H) HS SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
1100mm (H) HP SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
^
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
31
04 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
2
3
4
5
6
7
HR
FS3-1-005A
FS3-1-005BHR
ST-76
HP400 NOS
AZ50 NOS
CAS700 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
CAP500 NOS
AW350 NOS
HP300 NOS
SR550 NOS
HS650 NOS
DFL150 NOS CAP
350 NOS DFL220 NOS
SR250 NOS
AZ250 NOS
SR520 NOS
HP350 NOS SR
340 NOS
AZ600 NOS JG
450 NOS HS250 NOS
ABG100 NOS
AZ250 NOS
SR650 NOS
JG900 NOS
PA200 NOS
HP250 NOS
AW850 NOS
CAS850 NOS
CAP800 NOS
CAS850 NOS
SR350 NOS
PA500 NOS
HP300 NOS
500
500
0
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
5398
5085
5258
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 2 of 4)
3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
29
41 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
B C E FDA
HR
11
FS3-1-005B
CFA180 NOS
CFC250 NOS
CFC150 NOS
CFB450 NOS
CFA250 NOS
JG150 NOS
DE350 NOS
OJ3050 NOS
DE350 NOS
ZCI2100 NOS
CAS400 NOS
CGY50 NOS
CGY250 NOS
CFC250 NOS
CFA550 NOS
TS60 NOS
CGY250 NOS
CFT150 NOS
ABO80 NOS
CFT80 NOS
ABO60 NOS
JG150 NOS
CFC100 NOS
CFA150 NOS
CGY250 NOS
CFA250 NOS
CFT500 NOS
CFA300 NOS
YGC150 NOS
CAS150 NOS
CT200 NOS
TS50 NOS
CFC150 NOS
CGY350 NOS
CFB350 NOS
ZCA2000 NOS
DE550 NOS
ZCI1450 NOS
DE100 NOS
ZCA1200 NOS ZCI
4400 NOS
DE550 NOS
ZCI4250 NOS
JG150 NOS
CFC50 NOS
CGY500 NOS
CFB200 NOS
CFA450 NOS
BC200 NOS
CFA392 NOS
FFS25 NOS
CGY600 NOS
CAS250 NOS
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
BC350 NOS
CFC800 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
ZCI3550 NOSOJ
250 NOSZCI
1350 NOSDE
450 NOS
ZCA2250 NOS
NCA150 NOS
150 NOS
CGY450 NOS
CFB50 NOS
CFA300 NOS
CAS200 NOSCGY
250 NOSCFA520 NOS
FFS60 NOS
BC100 NOS
CTSON 051
500
500
500
500
500
500
500
500
CAS120 NOS
TOP VENT OPENING
900 x 900ACCESSHATCH
900 x 900ACCESSHATCH
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
NOTES
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 3 of 4)
3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
^
^
^
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
35
44 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
HR
11
FS3-1-005A
FS3-1-005BHR
ST-76
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
NCA150 NOS
CFA100 NOS
CVI150 NOS
CFT350 NOS
JG150 NOS ZCI
2000 NOS
NCA60 NOS
ZCA2300 NOS
CFC150 NOS
JG100 NOS
ZCA1250 NOS
ZCI2500 NOS
NCA250 NOS
ZCA400 NOS
CFT400 NOS
ZCI600 NOS
CT250 NOS
CFC650 NOS JG
110 NOS
CFC50 NOS
OJ1350 NOS
CFB160 NOS
CFA500 NOS
DE750 NOS
ZCA5050 NOS
OJ2650 NOS
ZCI3750 NOS
ZCA3850 NOS
CFT1150 NOS
CT450 NOS
CT250 NOSCAS
800 NOSJG250 NOS
CT950 NOS
CAS100 NOS
CGY350 NOS
CT350 NOS
CAS500 NOS
CFT200 NOS
CT150 NOS
OGY100 NOS
CFA550 NOS
CFC200 NOS
CVI150 NOS
FFS100 NOS
CFB150 NOS
JG200 NOS
ABG250 NOS
CFC750 NOS
CFA450 NOS
CFC300 NOS
CVI150 NOS
CFB100 NOS
TSC100 NOS
ZCA2000 NOS
CGY300 NOS
CFT1200 NOS
BC250 NOS
JG100 NOS
CFC60 NOS
CVI50 NOS
CFB100 NOS
CVI50 NOSCGY
100 NOS
CAS250 NOS
CGY300 NOS
CFA1000 NOS
CAS900 NOS
CT550 NOSCVI
550 NOS
CFT400 NOS
CGY450 NOS
CFB50 NOS
BC100 NOS
CFA900 NOS
CFT350 NOS
CVI450 NOS
CT650 NOS
CVI250 NOS
4201
700
0
6756NCA60 NOS
TOP VENT OPENING
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 4 of 4)
3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^ ^
900mm (H) CT SURROUNDTHE DOG HOUSE FORSCREENING OFF
^
^
^
^
^
^
900mm (H) CFC SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
52
08 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
1
1
7
6
5
4
3
2
G H J K L M
CAG
FIP
(ALTERNATE PLANTING)
SELF-CLINGING CLIMBER
PLANTING ON VERTICAL
BOUNDARY WALL
ARTIST
SQUARE
CSF
STAFF
ENTRANCE
ST
PR
LT-51
LT-53
LT-52
ART
LIFT
ST
PR
MEP
UP
UP
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
STREET FIRE HYDRANT
P39B BOUNDARY
400mm WIDTH
CLIMBER PLANTING AREA
DO NOT HYDROSEED
EPA
P39B BOUNDARY
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-G
AM
-L
AN
-D
WG
-9
00
2-P
00
-L
00
0-W
S4
1 TREE AND SHRUB SCHEDULE FOR GF REFER TO DRAWING NO
3AXXX-GAM-LAN-DWG-9002-P00-L000-WS4
NOTES
LEGEND
BOUNDARY LINE
HYDROSEEDING
CLIMBER PLANTING AREA
SELF-CLINGING CLIMBER
ALONG WALL
PROPRIETARY WIRE
GREEN WALL SYSTEM
TREE
P39B HYDROSEEDING SEED MIX
SCIENTIFIC NAME CHINESE NAME RATE
IMPERATA CYLINDRICA 白茅 20 GSQM
CELOSIA ARGENTEA 青葙 5 GSQM
KALIMERIS INDICA 馬蘭 5 GSQM
P39B CLIMBER SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) SPACING (MM) QTY REMARKS
CAG CAMPSIS GRANDIFLORA 凌霄 600 - 200 700 4 SHOOTS PER PLANT
FIP FICUS PUMILA 薜荔 600 - 200 630 4 SHOOTS PER PLANT
ALL CLIMBER SPECIES ARE TO BEALTERNATELY PLANTED
Native Species
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFSFIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Medium
Theatre I
Medium
Theatre IICCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega Perfo
rmance V
enue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
GF LANDSCAPE TREES
AND SHRUBS PLAN
(SHEET 2 of 2)
3AXXX-GAM-LAN-DWG-9003-P00-L000-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01
11102019 101916 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
1
2
3
4
5
6
7
7
HR
FS3-1-005B
PA250 NOS
CAP750 NOS
AW700 NOS
CAS650 NOS
HP250 NOS
IC350 NOS
HS50 NOS
IC350 NOS
AZ250 NOS
HS350 NOS
SR490 NOS
HP150 NOS
HP950 NOS
HP250 NOS
SR300 NOS
CAS200 NOS
CA515 NOS
JG350
HS250 NOS
HP450 NOS
HS350 NOS
CAS450 NOS
JG150 NOS
AW200 NOS
CAP700 NOS
SR600 NOS
AZ350 NOS PA
650 NOS
JG1250 NOS
CAS350 NOS
CA450 NOS
SR500 NOS
DFL150 NOS
ABO150 NOS
HP450 NOS
HS400 NOS
HS150 NOS
SR250 NOS
HP400 NOS
AZ50 NOS
AZ350 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
AZ750 NOS
CAP500 NOS
CA150 NOS
FFS30 NOS
AZ200 NOS
HP300 NOS
CAP400 NOS
DFL100 NOS
500500
500
500
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 4)
3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
900mm (H) HS SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
1100mm (H) HP SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
^
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
31
04 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
2
3
4
5
6
7
HR
FS3-1-005A
FS3-1-005BHR
ST-76
HP400 NOS
AZ50 NOS
CAS700 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
CAP500 NOS
AW350 NOS
HP300 NOS
SR550 NOS
HS650 NOS
DFL150 NOS CAP
350 NOS DFL220 NOS
SR250 NOS
AZ250 NOS
SR520 NOS
HP350 NOS SR
340 NOS
AZ600 NOS JG
450 NOS HS250 NOS
ABG100 NOS
AZ250 NOS
SR650 NOS
JG900 NOS
PA200 NOS
HP250 NOS
AW850 NOS
CAS850 NOS
CAP800 NOS
CAS850 NOS
SR350 NOS
PA500 NOS
HP300 NOS
500
500
0
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
5398
5085
5258
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 2 of 4)
3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
29
41 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
B C E FDA
HR
11
FS3-1-005B
CFA180 NOS
CFC250 NOS
CFC150 NOS
CFB450 NOS
CFA250 NOS
JG150 NOS
DE350 NOS
OJ3050 NOS
DE350 NOS
ZCI2100 NOS
CAS400 NOS
CGY50 NOS
CGY250 NOS
CFC250 NOS
CFA550 NOS
TS60 NOS
CGY250 NOS
CFT150 NOS
ABO80 NOS
CFT80 NOS
ABO60 NOS
JG150 NOS
CFC100 NOS
CFA150 NOS
CGY250 NOS
CFA250 NOS
CFT500 NOS
CFA300 NOS
YGC150 NOS
CAS150 NOS
CT200 NOS
TS50 NOS
CFC150 NOS
CGY350 NOS
CFB350 NOS
ZCA2000 NOS
DE550 NOS
ZCI1450 NOS
DE100 NOS
ZCA1200 NOS ZCI
4400 NOS
DE550 NOS
ZCI4250 NOS
JG150 NOS
CFC50 NOS
CGY500 NOS
CFB200 NOS
CFA450 NOS
BC200 NOS
CFA392 NOS
FFS25 NOS
CGY600 NOS
CAS250 NOS
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
BC350 NOS
CFC800 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
ZCI3550 NOSOJ
250 NOSZCI
1350 NOSDE
450 NOS
ZCA2250 NOS
NCA150 NOS
150 NOS
CGY450 NOS
CFB50 NOS
CFA300 NOS
CAS200 NOSCGY
250 NOSCFA520 NOS
FFS60 NOS
BC100 NOS
CTSON 051
500
500
500
500
500
500
500
500
CAS120 NOS
TOP VENT OPENING
900 x 900ACCESSHATCH
900 x 900ACCESSHATCH
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
NOTES
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 3 of 4)
3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
^
^
^
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
35
44 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
HR
11
FS3-1-005A
FS3-1-005BHR
ST-76
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
NCA150 NOS
CFA100 NOS
CVI150 NOS
CFT350 NOS
JG150 NOS ZCI
2000 NOS
NCA60 NOS
ZCA2300 NOS
CFC150 NOS
JG100 NOS
ZCA1250 NOS
ZCI2500 NOS
NCA250 NOS
ZCA400 NOS
CFT400 NOS
ZCI600 NOS
CT250 NOS
CFC650 NOS JG
110 NOS
CFC50 NOS
OJ1350 NOS
CFB160 NOS
CFA500 NOS
DE750 NOS
ZCA5050 NOS
OJ2650 NOS
ZCI3750 NOS
ZCA3850 NOS
CFT1150 NOS
CT450 NOS
CT250 NOSCAS
800 NOSJG250 NOS
CT950 NOS
CAS100 NOS
CGY350 NOS
CT350 NOS
CAS500 NOS
CFT200 NOS
CT150 NOS
OGY100 NOS
CFA550 NOS
CFC200 NOS
CVI150 NOS
FFS100 NOS
CFB150 NOS
JG200 NOS
ABG250 NOS
CFC750 NOS
CFA450 NOS
CFC300 NOS
CVI150 NOS
CFB100 NOS
TSC100 NOS
ZCA2000 NOS
CGY300 NOS
CFT1200 NOS
BC250 NOS
JG100 NOS
CFC60 NOS
CVI50 NOS
CFB100 NOS
CVI50 NOSCGY
100 NOS
CAS250 NOS
CGY300 NOS
CFA1000 NOS
CAS900 NOS
CT550 NOSCVI
550 NOS
CFT400 NOS
CGY450 NOS
CFB50 NOS
BC100 NOS
CFA900 NOS
CFT350 NOS
CVI450 NOS
CT650 NOS
CVI250 NOS
4201
700
0
6756NCA60 NOS
TOP VENT OPENING
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 4 of 4)
3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^ ^
900mm (H) CT SURROUNDTHE DOG HOUSE FORSCREENING OFF
^
^
^
^
^
^
900mm (H) CFC SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
52
08 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
1
2
3
4
5
6
7
7
HR
FS3-1-005B
PA250 NOS
CAP750 NOS
AW700 NOS
CAS650 NOS
HP250 NOS
IC350 NOS
HS50 NOS
IC350 NOS
AZ250 NOS
HS350 NOS
SR490 NOS
HP150 NOS
HP950 NOS
HP250 NOS
SR300 NOS
CAS200 NOS
CA515 NOS
JG350
HS250 NOS
HP450 NOS
HS350 NOS
CAS450 NOS
JG150 NOS
AW200 NOS
CAP700 NOS
SR600 NOS
AZ350 NOS PA
650 NOS
JG1250 NOS
CAS350 NOS
CA450 NOS
SR500 NOS
DFL150 NOS
ABO150 NOS
HP450 NOS
HS400 NOS
HS150 NOS
SR250 NOS
HP400 NOS
AZ50 NOS
AZ350 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
AZ750 NOS
CAP500 NOS
CA150 NOS
FFS30 NOS
AZ200 NOS
HP300 NOS
CAP400 NOS
DFL100 NOS
500500
500
500
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 1 of 4)
3AXXX-GAM-LAN-DWG-9005-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
900mm (H) HS SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
1100mm (H) HP SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
^
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
31
04 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
1
2
3
4
5
6
7
HR
FS3-1-005A
FS3-1-005BHR
ST-76
HP400 NOS
AZ50 NOS
CAS700 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
CAP500 NOS
AW350 NOS
HP300 NOS
SR550 NOS
HS650 NOS
DFL150 NOS CAP
350 NOS DFL220 NOS
SR250 NOS
AZ250 NOS
SR520 NOS
HP350 NOS SR
340 NOS
AZ600 NOS JG
450 NOS HS250 NOS
ABG100 NOS
AZ250 NOS
SR650 NOS
JG900 NOS
PA200 NOS
HP250 NOS
AW850 NOS
CAS850 NOS
CAP800 NOS
CAS850 NOS
SR350 NOS
PA500 NOS
HP300 NOS
500
500
0
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
5398
5085
5258
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 2 of 4)
3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
29
41 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
B C E FDA
HR
11
FS3-1-005B
CFA180 NOS
CFC250 NOS
CFC150 NOS
CFB450 NOS
CFA250 NOS
JG150 NOS
DE350 NOS
OJ3050 NOS
DE350 NOS
ZCI2100 NOS
CAS400 NOS
CGY50 NOS
CGY250 NOS
CFC250 NOS
CFA550 NOS
TS60 NOS
CGY250 NOS
CFT150 NOS
ABO80 NOS
CFT80 NOS
ABO60 NOS
JG150 NOS
CFC100 NOS
CFA150 NOS
CGY250 NOS
CFA250 NOS
CFT500 NOS
CFA300 NOS
YGC150 NOS
CAS150 NOS
CT200 NOS
TS50 NOS
CFC150 NOS
CGY350 NOS
CFB350 NOS
ZCA2000 NOS
DE550 NOS
ZCI1450 NOS
DE100 NOS
ZCA1200 NOS ZCI
4400 NOS
DE550 NOS
ZCI4250 NOS
JG150 NOS
CFC50 NOS
CGY500 NOS
CFB200 NOS
CFA450 NOS
BC200 NOS
CFA392 NOS
FFS25 NOS
CGY600 NOS
CAS250 NOS
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
BC350 NOS
CFC800 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
ZCI3550 NOSOJ
250 NOSZCI
1350 NOSDE
450 NOS
ZCA2250 NOS
NCA150 NOS
150 NOS
CGY450 NOS
CFB50 NOS
CFA300 NOS
CAS200 NOSCGY
250 NOSCFA520 NOS
FFS60 NOS
BC100 NOS
CTSON 051
500
500
500
500
500
500
500
500
CAS120 NOS
TOP VENT OPENING
900 x 900ACCESSHATCH
900 x 900ACCESSHATCH
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
NOTES
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 3 of 4)
3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
^
^
^
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
35
44 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
HR
11
FS3-1-005A
FS3-1-005BHR
ST-76
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
NCA150 NOS
CFA100 NOS
CVI150 NOS
CFT350 NOS
JG150 NOS ZCI
2000 NOS
NCA60 NOS
ZCA2300 NOS
CFC150 NOS
JG100 NOS
ZCA1250 NOS
ZCI2500 NOS
NCA250 NOS
ZCA400 NOS
CFT400 NOS
ZCI600 NOS
CT250 NOS
CFC650 NOS JG
110 NOS
CFC50 NOS
OJ1350 NOS
CFB160 NOS
CFA500 NOS
DE750 NOS
ZCA5050 NOS
OJ2650 NOS
ZCI3750 NOS
ZCA3850 NOS
CFT1150 NOS
CT450 NOS
CT250 NOSCAS
800 NOSJG250 NOS
CT950 NOS
CAS100 NOS
CGY350 NOS
CT350 NOS
CAS500 NOS
CFT200 NOS
CT150 NOS
OGY100 NOS
CFA550 NOS
CFC200 NOS
CVI150 NOS
FFS100 NOS
CFB150 NOS
JG200 NOS
ABG250 NOS
CFC750 NOS
CFA450 NOS
CFC300 NOS
CVI150 NOS
CFB100 NOS
TSC100 NOS
ZCA2000 NOS
CGY300 NOS
CFT1200 NOS
BC250 NOS
JG100 NOS
CFC60 NOS
CVI50 NOS
CFB100 NOS
CVI50 NOSCGY
100 NOS
CAS250 NOS
CGY300 NOS
CFA1000 NOS
CAS900 NOS
CT550 NOSCVI
550 NOS
CFT400 NOS
CGY450 NOS
CFB50 NOS
BC100 NOS
CFA900 NOS
CFT350 NOS
CVI450 NOS
CT650 NOS
CVI250 NOS
4201
700
0
6756NCA60 NOS
TOP VENT OPENING
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 4 of 4)
3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^ ^
900mm (H) CT SURROUNDTHE DOG HOUSE FORSCREENING OFF
^
^
^
^
^
^
900mm (H) CFC SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
52
08 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
1
2
3
4
5
6
7
HR
FS3-1-005A
FS3-1-005BHR
ST-76
HP400 NOS
AZ50 NOS
CAS700 NOS
SR650 NOS AZ
400 NOS
HP400 NOS
CAP500 NOS
AW350 NOS
HP300 NOS
SR550 NOS
HS650 NOS
DFL150 NOS CAP
350 NOS DFL220 NOS
SR250 NOS
AZ250 NOS
SR520 NOS
HP350 NOS SR
340 NOS
AZ600 NOS JG
450 NOS HS250 NOS
ABG100 NOS
AZ250 NOS
SR650 NOS
JG900 NOS
PA200 NOS
HP250 NOS
AW850 NOS
CAS850 NOS
CAP800 NOS
CAS850 NOS
SR350 NOS
PA500 NOS
HP300 NOS
500
500
0
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
3AXX
X-GA
M-LA
N-DW
G-90
06-P
00-L
003-
WS4
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
5398
5085
5258
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 2 of 4)
3AXXX-GAM-LAN-DWG-9006-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
29
41 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
B C E FDA
HR
11
FS3-1-005B
CFA180 NOS
CFC250 NOS
CFC150 NOS
CFB450 NOS
CFA250 NOS
JG150 NOS
DE350 NOS
OJ3050 NOS
DE350 NOS
ZCI2100 NOS
CAS400 NOS
CGY50 NOS
CGY250 NOS
CFC250 NOS
CFA550 NOS
TS60 NOS
CGY250 NOS
CFT150 NOS
ABO80 NOS
CFT80 NOS
ABO60 NOS
JG150 NOS
CFC100 NOS
CFA150 NOS
CGY250 NOS
CFA250 NOS
CFT500 NOS
CFA300 NOS
YGC150 NOS
CAS150 NOS
CT200 NOS
TS50 NOS
CFC150 NOS
CGY350 NOS
CFB350 NOS
ZCA2000 NOS
DE550 NOS
ZCI1450 NOS
DE100 NOS
ZCA1200 NOS ZCI
4400 NOS
DE550 NOS
ZCI4250 NOS
JG150 NOS
CFC50 NOS
CGY500 NOS
CFB200 NOS
CFA450 NOS
BC200 NOS
CFA392 NOS
FFS25 NOS
CGY600 NOS
CAS250 NOS
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
BC350 NOS
CFC800 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
ZCI3550 NOSOJ
250 NOSZCI
1350 NOSDE
450 NOS
ZCA2250 NOS
NCA150 NOS
150 NOS
CGY450 NOS
CFB50 NOS
CFA300 NOS
CAS200 NOSCGY
250 NOSCFA520 NOS
FFS60 NOS
BC100 NOS
CTSON 051
500
500
500
500
500
500
500
500
CAS120 NOS
TOP VENT OPENING
900 x 900ACCESSHATCH
900 x 900ACCESSHATCH
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
NOTES
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 3 of 4)
3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
^
^
^
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
35
44 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
HR
11
FS3-1-005A
FS3-1-005BHR
ST-76
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
NCA150 NOS
CFA100 NOS
CVI150 NOS
CFT350 NOS
JG150 NOS ZCI
2000 NOS
NCA60 NOS
ZCA2300 NOS
CFC150 NOS
JG100 NOS
ZCA1250 NOS
ZCI2500 NOS
NCA250 NOS
ZCA400 NOS
CFT400 NOS
ZCI600 NOS
CT250 NOS
CFC650 NOS JG
110 NOS
CFC50 NOS
OJ1350 NOS
CFB160 NOS
CFA500 NOS
DE750 NOS
ZCA5050 NOS
OJ2650 NOS
ZCI3750 NOS
ZCA3850 NOS
CFT1150 NOS
CT450 NOS
CT250 NOSCAS
800 NOSJG250 NOS
CT950 NOS
CAS100 NOS
CGY350 NOS
CT350 NOS
CAS500 NOS
CFT200 NOS
CT150 NOS
OGY100 NOS
CFA550 NOS
CFC200 NOS
CVI150 NOS
FFS100 NOS
CFB150 NOS
JG200 NOS
ABG250 NOS
CFC750 NOS
CFA450 NOS
CFC300 NOS
CVI150 NOS
CFB100 NOS
TSC100 NOS
ZCA2000 NOS
CGY300 NOS
CFT1200 NOS
BC250 NOS
JG100 NOS
CFC60 NOS
CVI50 NOS
CFB100 NOS
CVI50 NOSCGY
100 NOS
CAS250 NOS
CGY300 NOS
CFA1000 NOS
CAS900 NOS
CT550 NOSCVI
550 NOS
CFT400 NOS
CGY450 NOS
CFB50 NOS
BC100 NOS
CFA900 NOS
CFT350 NOS
CVI450 NOS
CT650 NOS
CVI250 NOS
4201
700
0
6756NCA60 NOS
TOP VENT OPENING
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 4 of 4)
3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^ ^
900mm (H) CT SURROUNDTHE DOG HOUSE FORSCREENING OFF
^
^
^
^
^
^
900mm (H) CFC SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
52
08 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
8
9
10
12
13
14
B C E FDA
HR
11
FS3-1-005B
CFA180 NOS
CFC250 NOS
CFC150 NOS
CFB450 NOS
CFA250 NOS
JG150 NOS
DE350 NOS
OJ3050 NOS
DE350 NOS
ZCI2100 NOS
CAS400 NOS
CGY50 NOS
CGY250 NOS
CFC250 NOS
CFA550 NOS
TS60 NOS
CGY250 NOS
CFT150 NOS
ABO80 NOS
CFT80 NOS
ABO60 NOS
JG150 NOS
CFC100 NOS
CFA150 NOS
CGY250 NOS
CFA250 NOS
CFT500 NOS
CFA300 NOS
YGC150 NOS
CAS150 NOS
CT200 NOS
TS50 NOS
CFC150 NOS
CGY350 NOS
CFB350 NOS
ZCA2000 NOS
DE550 NOS
ZCI1450 NOS
DE100 NOS
ZCA1200 NOS ZCI
4400 NOS
DE550 NOS
ZCI4250 NOS
JG150 NOS
CFC50 NOS
CGY500 NOS
CFB200 NOS
CFA450 NOS
BC200 NOS
CFA392 NOS
FFS25 NOS
CGY600 NOS
CAS250 NOS
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
BC350 NOS
CFC800 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
ZCI3550 NOSOJ
250 NOSZCI
1350 NOSDE
450 NOS
ZCA2250 NOS
NCA150 NOS
150 NOS
CGY450 NOS
CFB50 NOS
CFA300 NOS
CAS200 NOSCGY
250 NOSCFA520 NOS
FFS60 NOS
BC100 NOS
CTSON 051
500
500
500
500
500
500
500
500
CAS120 NOS
TOP VENT OPENING
900 x 900ACCESSHATCH
900 x 900ACCESSHATCH
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NO3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
NOTES
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 3 of 4)
3AXXX-GAM-LAN-DWG-9007-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
^
^
^
^
^
^
^
^
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
35
44 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
8
9
10
12
13
14
HR
11
FS3-1-005A
FS3-1-005BHR
ST-76
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
NCA150 NOS
CFA100 NOS
CVI150 NOS
CFT350 NOS
JG150 NOS ZCI
2000 NOS
NCA60 NOS
ZCA2300 NOS
CFC150 NOS
JG100 NOS
ZCA1250 NOS
ZCI2500 NOS
NCA250 NOS
ZCA400 NOS
CFT400 NOS
ZCI600 NOS
CT250 NOS
CFC650 NOS JG
110 NOS
CFC50 NOS
OJ1350 NOS
CFB160 NOS
CFA500 NOS
DE750 NOS
ZCA5050 NOS
OJ2650 NOS
ZCI3750 NOS
ZCA3850 NOS
CFT1150 NOS
CT450 NOS
CT250 NOSCAS
800 NOSJG250 NOS
CT950 NOS
CAS100 NOS
CGY350 NOS
CT350 NOS
CAS500 NOS
CFT200 NOS
CT150 NOS
OGY100 NOS
CFA550 NOS
CFC200 NOS
CVI150 NOS
FFS100 NOS
CFB150 NOS
JG200 NOS
ABG250 NOS
CFC750 NOS
CFA450 NOS
CFC300 NOS
CVI150 NOS
CFB100 NOS
TSC100 NOS
ZCA2000 NOS
CGY300 NOS
CFT1200 NOS
BC250 NOS
JG100 NOS
CFC60 NOS
CVI50 NOS
CFB100 NOS
CVI50 NOSCGY
100 NOS
CAS250 NOS
CGY300 NOS
CFA1000 NOS
CAS900 NOS
CT550 NOSCVI
550 NOS
CFT400 NOS
CGY450 NOS
CFB50 NOS
BC100 NOS
CFA900 NOS
CFT350 NOS
CVI450 NOS
CT650 NOS
CVI250 NOS
4201
700
0
6756NCA60 NOS
TOP VENT OPENING
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 4 of 4)
3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^ ^
900mm (H) CT SURROUNDTHE DOG HOUSE FORSCREENING OFF
^
^
^
^
^
^
900mm (H) CFC SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
52
08 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
8
9
10
12
13
14
HR
11
FS3-1-005A
FS3-1-005BHR
ST-76
CFA700 NOS
CFB350 NOS
BC150 NOS
CGY350 NOS
CFA500 NOS
ZCA5750 NOS
DE250 NOS
NCA150 NOS
CFA100 NOS
CVI150 NOS
CFT350 NOS
JG150 NOS ZCI
2000 NOS
NCA60 NOS
ZCA2300 NOS
CFC150 NOS
JG100 NOS
ZCA1250 NOS
ZCI2500 NOS
NCA250 NOS
ZCA400 NOS
CFT400 NOS
ZCI600 NOS
CT250 NOS
CFC650 NOS JG
110 NOS
CFC50 NOS
OJ1350 NOS
CFB160 NOS
CFA500 NOS
DE750 NOS
ZCA5050 NOS
OJ2650 NOS
ZCI3750 NOS
ZCA3850 NOS
CFT1150 NOS
CT450 NOS
CT250 NOSCAS
800 NOSJG250 NOS
CT950 NOS
CAS100 NOS
CGY350 NOS
CT350 NOS
CAS500 NOS
CFT200 NOS
CT150 NOS
OGY100 NOS
CFA550 NOS
CFC200 NOS
CVI150 NOS
FFS100 NOS
CFB150 NOS
JG200 NOS
ABG250 NOS
CFC750 NOS
CFA450 NOS
CFC300 NOS
CVI150 NOS
CFB100 NOS
TSC100 NOS
ZCA2000 NOS
CGY300 NOS
CFT1200 NOS
BC250 NOS
JG100 NOS
CFC60 NOS
CVI50 NOS
CFB100 NOS
CVI50 NOSCGY
100 NOS
CAS250 NOS
CGY300 NOS
CFA1000 NOS
CAS900 NOS
CT550 NOSCVI
550 NOS
CFT400 NOS
CGY450 NOS
CFB50 NOS
BC100 NOS
CFA900 NOS
CFT350 NOS
CVI450 NOS
CT650 NOS
CVI250 NOS
4201
700
0
6756NCA60 NOS
TOP VENT OPENING
MATC
H LIN
ERE
FER
TO D
RAW
ING
NO
AR20
19M
ELO
DW30
04
MATCH LINEREFER TO DRAWING NOAR2019MELODW3004
FPTJTRA (ALTERNATEPLANTING)
LEGEND
FOR 3F PODIUM PLANTING SCHEDULE REFER TODRAWINGS3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4
FPTJ (ALTERNATEPLANTING)
NOTE
1 100 SCALE BAR
0 25 5m
N KEY PLAN
ALL DIMENSIONS ARE IN MILLIMETER UNLESSOTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGUREDDIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OFINDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR STRUCTURAL ELEMENTS
BME HVACMECHANICAL ELEMENTS
BTG GAS ELEMENTS
BDR DRAINAGE ELEMENTS
BEL ELECTRICAL ELEMENTS
BPL PLUMBING ELEMENTS
BFS FIRE PROTECTION ELEMENTS
MEP COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
24P
A34P
94P
84P
P45
74P
B34P
53P
ERAUQS TSITRA
64P
gnissorC ruobraH nretseW gnidliuB noitalitneV noitalitneV yawliaR tropriA gnidliuB noitatsbuS noitcarT dna
ertaehT ciryL
23P
43P92P
72P 42P
81P
22P
51P 31P
LARTNECERAUQS
13P82P
52P
32P
71P 61P
02P
12P
11P 01P20P 30P
40P
90P
60P
UQIXERAUQS
8P
21P41P
muideMI ertaehT
muideMII ertaehTPCC
cisuMertneClacisuM
ertaehT
03P
ertaehT taerG
91P
10PuqiX
ertneC
PLC-buS
noitatS
euneV ecnamrofreP ageMertneC noitibihxE
ANERAAZALP
Existing Salt WaterPumping Station
PARK05P
44P
strAnoilivaP25P
50P
70P
62P
kcalBxoB
15P
A05P kraP gnicafretnI +M
N
04P+M
P39AB93P
FSCRDE
MUSEUM PLUS (M+) OFTHE WEST KOWLOONCULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F LANDSCAPE TREESAND SHRUBS PLAN(SHEET 4 of 4)
3AXXX-GAM-LAN-DWG-9008-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOREASY REFERENCE
^ = ALTERNATIVE SPECIES
^ ^
900mm (H) CT SURROUNDTHE DOG HOUSE FORSCREENING OFF
^
^
^
^
^
^
900mm (H) CFC SURROUNDTHE DOG HOUSE FOR
SCREENING OFF
00 20 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
02
02 23 NOV 2019 SHOP DRAWING RESUBMISSION
281
120
19 2
52
08 P
M I
SO fu
ll bl
eed
A0 (8
410
0 x
1189
00
MM
) 1
1
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
A0 (1188mm x 840mm) Sheet
Size
ALL DIMENSIONS ARE IN MILLIMETER UNLESS
OTHERWISE SPECIFIED
DO NOT SCALE THE DRAWING FIGURED
DIMENSIONS ARE TO BE FOLLOWED
1
2
GENERAL NOTES
LEGEND SHOULD REFER TO SHOP DRAWING OF
INDIVIDUAL TRADE
3
4
KEY PLAN
DISCIPLINE COLOUR CODE
REFERENCE
ARC
DISCIPLINE
ARCHITECTURAL ELEMENTS
STR
STRUCTURAL ELEMENTS
BME
HVACMECHANICAL ELEMENTS
BTG
GAS ELEMENTS
BDR
DRAINAGE ELEMENTS
BEL
ELECTRICAL ELEMENTS
BPL
PLUMBING ELEMENTS
BFS
FIRE PROTECTION ELEMENTS
MEP
COMBINED SERVICES ELEMENTS
COLOUR
GAMMON CONSTRUCTION LIMITED
MANAGEMENT CONTRACTOR
28F Devon House TaiKoo Place 979 Kings Road Hong Kong
KEY PLAN
P42
P43A
P49
P48
P45
P47
P43B
P35
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQUARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Medium
Theatre II
CC
P
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
CLP
Sub-
Station
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
N
P40
M+
P39A
P39B
CSF
RDE
MUSEUM PLUS (M+) OF
THE WEST KOWLOON
CULTURAL DISTRICT
PROJECT
DRAWING NO
PRODUCED BY
APPROVED
CHECKED
SCALE PRINTED
DATE
DATE
DATE
REV
AUTHORITY
PHASE
DISCIPLINE
AUTHOR
SUB CONTRACTOR
TEL 2572 0048 FAX 2573 9099
125 HA YAU TIN TSUEN YUEN LONG NT HONG KONG
E-MAIL INFOMELOFIELDCOM
3F SHRUBS AND
GROUNDCOVER
SCHEDULE
3AXXX-GAM-LAN-DWG-9009-P00-L003-WS4 00
00
ALL ALTERNATIVE SPECIES ARE CLOUDED IN RED FOR
EASY REFERENCE
0020 SEP 2019 1ST SHOP DRAWING SUBMISSION
01 02 OCT 2019 SHOP DRAWING RESUBMISSION
01
3154
950
1575
02102019 105923 A
M IS
O full bleed A
0 (84100 x 118900 M
M) 11
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
B1-1-044
CAFE KITCHEN
268 msup2
B1-1-053
MUSEUM CAFE 1
885 msup2
B1-1-048
CAFE TOILET MALE
27 msup2
CATERING TABLE amp
CHAIR STORAGE
91 msup2
FS
B1-1-050
CAFE TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-045
CAFE TOILET FEMALE
31 msup2
B1-1-904M
CENTRAL CONTROL
CENTRE
70 msup2
SVB2
07
10
SVB2
12
SC
FS
DROP TO 25m AFFL
TEMPORARY
MAINTENANCE
VEHICLE PARKING
+6550
MUSEUM ENTRANCE
MUSEUM CAFE ENTRANCE
LT-21
ST PR
L PR
LIFT PIT
112UP
HR
HR
B1-1-342
CORRIDOR
3 msup2
B1-1-060
CAFE TOILET CLEANING
ROOM
1 msup2
HR
HR
HR
SPCV
ACCESIBLE
5 msup2
B1-1-059
STAFF TOILET MALE
5 msup2
A
+6300
+6300
+6300
ST-71
CORE amp SHELL
SC
DROP TO 25m AFFL
+6300
INTERFACING
PARK
EVA
EVA
11
12
13
14
A B
C D E F
Tm
Tm
Tm
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
3 NOS OF TREES WITHIN M+
BOUNDARY LOCATION TO BE
FURTHER COORDINATED ON SITE
10935
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
8-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
TURF (PASPALUM VAGINATUM ZOYSIA MATRELLA TIFTON 419
BERMYDAGRASS ) ARE THE TURF SPECIES THAT WILL BE USED IN THE PARK
NOTE
1 APPLY MULCH ON 1M DIAMETER CIRCLE AROUND ALL TREES IMMEDIATELY AFTER TREE
PLANTING KEEP MULCH AWAY FROM TREE TRUNK FLARE
2 APPLY HYDROSEEDING ONLY AFTER COMPLETION OF TREE PLANTING AND MULCHING
3 DO NO HYDROSEED INTO MULCHED AREA COVER ALL MULCHED AREA WITH NEWSPAPER
HESSIAN NYLON SHEET OR THE LIKE BEFORE HYDROSEEDING AND DISCARD AFTERWARDS
4 KEEP ALL MULCHED AREA FREE FROM GRASS GROWTH AT ALL TIMES
5 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE BOUNDARY ARE INDICATED
FOR REFERENCE ONLY SOFT LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE
CONTRACT
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
B1F - TREE SCHEDULE
CODE SCIENTIFIC NAME CHINESE NAME HEIGHT (MM) SPREAD (MM) DBH (MM) QTY REMARKS
Tm TERMINALIA MANTALY 小葉欖仁 5000 3000 100 3
(SHEET 1 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
UPUP
B1-1-051
DRESSING ROOMS
15 msup2
B1-1-047
AV WORKROOM STUDIO
26 msup2
B1-1-004
MOVING IMAGE CENTRE
OFFICES
28 msup2
B1-1-046
AV STORAGE 2
25 msup2
FS
B1-1-052
STAFF TOILET UNISEX
ACCESIBLE
6 msup2
B1-1-054
MUSEUM SHOP 2
182 msup2
SVB2
15
B1-1-806M
MEP
60 msup2
B1-1-055
MUSEUM SHOP
STORAGE 4
71 msup2
B1-1-059
CINEMA TOILET FEMALE
24 msup2
B1-1-006
CINEMA TOILET
CLEANING ROOM
2 msup2
+6300
B1-1-057
CINEMA TOILET MALE
17 msup2
FS
MEP
MEP
MEP
+5800
DELIVERY HATCH
TO B2F
B1-1-336
CORRIDOR
10 msup2
B1-1-707D
TRANSFORMER ROOM
FOR DCS
134 msup2
+5500
TH
+5850
MUSEUM ENTRANCE
MUSEUM SHOP ENTRANCE
FAD
LT-20
MEP
MEP
B1-1-951M
ICT
7 msup2
B1-1-905M
ELV
8 msup2
B1-ST-17
ST-17
39 msup2
FS
B1-1-349
LIFT LOBBY
11 msup2
B1-1-351
CORRIDOR
5 msup2
B1-1-952M
ELV LEAD IN ROOM
14 msup2
B1-1-049
ESPRESSO BAR
27 msup2
EL
EC
C
AB
IN
ET
HR
HR
HR
HR
LT-23
LT-19
A
D
D
+6300
+5500
+6300
ST-71
ST-72
ST-73
+5350
+6300
+5350
ST-84
ST-85
+5350
+6300
B1-1-066
MOVING IMAGE CENTRE
LOBBY
143 msup2
SC
DROP TO 25m AFFL
UP
UP
B1-1-343
LIFT LOBBY
8 msup2
B1-1-352
CORRIDOR
7 msup2
B1-ST-24
ST-24
12 msup2
B1-ST-17
ST-17
39 msup2
EVA
EVA
G H J K L M
10
11
12
13
14
THE PLANTER AREA AND TREES
OUTSIDE SITE BOUNDARY ARE
SHOWN FOR DESIGN TO BE
CARRIED OUT BY OTHERS
TEMPORARY LAWN AT
FORMATION LEVEL 200mm
BELOW ADJACENT HARDPAVING
PROVIDED BY OTHERS BEFORE
OP TEMPORARY PARAPET TO BE
DEMOLISHED AND PERMANENT
GRANITE PAVING TO BE
PROVIDED BY OTHERS AT THE
TIME OF L2 COMPLETION
L2 SITE (REFERENCE ONLY
CURRENT LEVEL AT +410mPD)
2470
10935
19800
MA
TC
H L
IN
E
RE
FE
R T
O D
RA
WIN
G N
O
3A
XX
X-T
FP
-L
AN
-D
WG
-0
50
7-P
00
-L
B0
1-W
S4
-0
2
BOUNDARY LINE
LEGEND
1 TREE AND SHRUB SCHEDULE FOR B1F REFER TO DRAWING NO
3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4
2 TREE AND TURF SPECIES AT B1F WITHIN AND OUTSIDE M+ SITE
BOUNDARY ARE INDICATED FOR REFERENCE ONLY SOFT
LANDSCAPE WORKS TO BE CARRIED OUT BY SEPARATE CONTRACT
NOTES
TURF (PASPALUM VAGINATUM ZOYSIA
MATRELLA TIFTON 419 BERMYDAGRASS ) ARETHE TURF SPECIES THAT WILL BE USED IN THE PARK
(SHEET 2 OF 2)
B1F LANDSCAPE TREES AND SHRUBS PLAN
TFPHdM
1 100 A0
TFPHdM
TFPHdM
28042017
28042017
28042017
TFPHdM
LAN
023AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4
WS4
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
1 100 SCALE BAR
0 25 5m
N
KEY PLAN
LEGEND
CAD REF NAME
DRAWING NO
DISCIPLINE
AUTHOR
PRODUCED BY
APPROVED
CHECKED
SCALE
DRAWING TITLE
JOB TITLE
REV DATE PURPOSE OF RELEASE PRODUCED BY
PRINTED
DATE
DATE
DATE
REV
NOTES
KEY PLAN
KEY PLAN
FSD REF
BD REF
3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02dwg
CONSULTANT
DESIGN CONSULTANT
EXECUTIVE ARCHITECT
ENGINEERING CONSULTANT
QUANTITY SURVEYOR
EMPLOYER
PHASE
HERZOG amp DE MEURON BASEL LTD RHEINSCHANZE 6 4056 BASEL
SWITZERLAND
TFP FARRELLS LIMITED SUITES 130-02 13F 625 KINGSROAD
NORTHPOINT HONG KONG
MJV SUBCONSULTANT
OVE ARUP amp PARTNERS HONG KONG LIMITED LEVEL5 FESTIVAL
WALK 80 TAT CHEE AVENUE KOWLOON TONG HONG KONG
AUTHORITYS CONSULTANT
MUSEUM PLUS (M+) OF THE
WEST KOWLOON CULTURAL
DISTRICT
UNLESS NOTED OTHERWISE COPYRIGHT AND DESIGN RIGHTS IN THIS DOCUMENT
ARE OWNED BY ONE OR ALL OF THE MEMBERS OF THE M+ CONSULTANCY JV FORMING
THE ldquoCONSULTANTrdquo WITHOUT DEROGATION TO ANY PROVISION OF THE
CONSULTANCY AGREEMENT THE CONSULTANT RESPECTIVELY THE MEMBER OF
THE M+ CONSULTANCY JV THAT OWNS SUCH INTELLECTUAL PROPERTY HAS
GRANTED AND GRANTS ONLY TO THE AUTHORITY ITS SUCCESSORS AND ASSIGNS A
PERPETUAL UNRESTRICTED EXCLUSIVE FREELY ASSIGNABLE AND IRREVOCABLE
WORLD-WIDE LICENCE (CARRYING THE RIGHT TO GRANT SUB LICENCES) TO USE
REPRODUCE MODIFY ADAPT AND TRANSLATE THE INTELLECTUAL PROPERTY IN
THIS DOCUMENT FOR ANY PURPOSE OF THE AUTHORITY NOTWITHSTANDING THE
ABOVE MENTIONED LICENCE THIS DOCUMENT SHALL BE MODIFIED ADAPTED OR
TRANSLATED ONLY BY THE MEMBER OF M+ CONSULTANCY JV INDICATED AS HAVING
PRODUCED THIS DOCUMENT THE USE OF THIS DOCUMENT AND THE INTELLECTUAL
PROPERTY VESTED THEREIN BY ANY OTHER PARTY THAN THOSE MENTIONED
ABOVE MUST BE SUBJECT TO AN AGREEMENT OR AUTHORISATION BY OR WITH THE
AUTHORITY
P42
P40
P43A
P49
P48
P45
P47
P43B
P35
M+
ARTIST S
QUARE
P46
Weste
rn H
arbour C
rossing
Ventilatio
n Build
ing
Airport
Railway V
entilatio
n
and Tra
ction S
ubstatio
n Build
ing
Lyric T
heatre
P32
P34
P29
P27
P24
P18
P22
P15
P13
CENTRAL
SQU
ARE
P31
P28
P25
P23
P17 P16
P20
P21
P11
P10
P02
P03
P04
P09
P06
XIQU
SQUARE
P8
P12
P14
Mediu
m
Theatre I
Mediu
m
Theatre II
CCP
Music
CentreMusical
Theatre
P30
Great T
heatre
P19
P01
Xiqu
Centre
P39A
P39B
M+ - CSF
CLP
Sub-
Sta
tion
Mega P
erform
ance Venue
Exhibition C
entre
ARENA
PLAZA
Existing Salt Water
Pumping Station
PA
RK
P50
P44
Arts
Pavilion
P52
P05
P07
P26
Black
Box
P51
P50A
M+ Interfa
cing Park
A0
TFPHdMCONSTRUCTION DRAWINGS2209201500
TFPHdMREVISED B1F PROMENADE3105201601
TFPHdMLAN LIGHTING DESIGN UPDATE2804201702
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX B NOT USED
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX C GREEN COVERAGE PLANS Drawing no- Description
3AXXX-TFP-ARC-SCH-9200-P00-XXXX-GBP Calculations of Site Coverage Plot Ratio Schedule of FRC and Diagrams
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX D POST-PLANTING CARE PLAN
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
a Replacement planting Replacement of dead dying plants eg failure grass species
Replanting andor reseeding of annual herbaceous plants depending on rate of self-regeneration
As directed by the Architect Immediately following weeding operations Preferably during planting season ie Mar-Sep
b Watering Watering of planted areas as required Daily operation except where rainfall gt 20mmday Early morning andor late afternoon
Duration of the irrigation system watering time to be reviewed periodically and any necessary adjustment made
c Weeding Removal of all non-specified plants for all planting areas 12 times per year ndash once every three weeks in growing season once every five weeks at other times
The three weeks weeding cycle ndash adjusted to five weeks in the winter season (continuous cycle of weeding)
d Noxious and invasive weeds Remove species of noxious and invasive weeds eg Mikania micrantha and Leucaena leucocephala immediately when discovered
Daily check as part of other inspections ndash immediate treatment as necessary
Observe the guidelines and practice notes promulgated by AFCD on treatment of noxious weeds
e Post-planting fertilizer Application of fertilizer to all planting areas Two applications with 100 to 300 days in first Spring Autumn after completion of planting grass laying
Application of fertilizer twice during the first year
f Soil aeration Forking over to a depth of 100mm for grass shrubs amp groundcover plants
First Spring Autumn following completion of planting Operation conducted concurrently with fertilizer application
g Mulching Topping up of mulch to specified depth Top up twice during the establishment period Timing dependent on completion of planting ndash first immediately after aeration + second immediately before end of Establishment Period
Observe GLTMS guidelines on keeping mulch away from trunk flare
h Firming up Firming of trees and shrubs to ensure plants are set upright and properly established in the ground
As directed by the Architect ndash immediately after strong winds typhoons and as necessary
Review on a monthly basis adjustments made as necessary
i Staking and tying Adjustment of stakes and tying materials for trees and palms to ensure that they are secure but allow room for plant growth
Review on a monthly basis adjustments made as necessary -
j Pruning of trees palms Pruning of trees and palms to remove dead or damaged branches fronds and to promote better canopy crown shape
(Formative pruning should be undertaken during plant preparation and immediately prior to planting)
According to species as determined by the Architect Observe relevant guidelines and Proper Planting Practices promulgated by GLTMS of DEVB
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
k Pruning of shrubs and groundcovers
Pruning of shrubs and groundcovers to encourage bushy growth tidy up appearance topiary as intended and remove dead diseased branches
Review on a monthly basis Prune according to species and agreed design intent as directed by the Architect
Pruning as necessary to maintain the agreed design height for shrubs (action trigger height down to pruned height for each species location)
l Training and pruning climbers Train climbers to obtain the desired effect Pruning of climbers to prevent uncontrolled spreading and strangling of other plants Adjust climber ties and wires to give proper support to climbing plants
As directed by the Architect Training and pruning according to agreed design intent Monthly check ties and wires and adjust as necessary
-
m Lawn care Includes grass cutting rolling weeding and general lawn care operations
Review on a weekly basis Cutting as required in accordance with grass height
Cut grass to a height of 50 mm when it reaches 100 mm high
n Top dressing for grass areas Top dress grass areas as required to smooth out minor depressions
Twice ndash timing to be agreed -
o Plant division Remove selected plants to reduce overcrowding and replant elsewhere on site
As directed by the Architect review on a monthly basis (Preferably during planting season ie Mar-Sep)
-
p Plant thinning Remove selected plants to reduce overcrowding and dispose off-site
As directed by the Architect Review on a monthly basis
-
q Infestation by rodents etc Check all planting areas for signs of infestation by rodents etc as part of the regular monthly inspection of the establishment works Treatment by pest control measures
Daily check as part of other inspections ndash immediately treatment as necessary
-
r Pest disease fungal growth and parasitic plants
Check all plants for signs of pest disease fungal growth and parasitic plants as part of the regular monthly inspection of the establishment works Treat pest disease and fungal growth by applying suitable chemical or pruning as appropriate Treat parasitic plants by physical removal
Daily check as part of other inspections ndash immediately treatment as necessary
-
s Protective fencing Check and repair protective fencing
As required -
t Typhoon damage Reinstatement of all displaced trees and shrubs treatment or replacement of damaged plants
As required -
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Description Frequency
Notes
u Clearance of unwanted vegetation
Carry out as part of site clearance and weeding Remove all unwanted vegetation including undersized wild growth undesirable to be kept at the location
As directed by the Architect -
v Litter collection Collection of litter and debris from site Daily operation across site
-
w Erosion control Application of erosion control measures as required preventing controlling soil erosions Repair of eroded areas
As required On-going exercise
x Removal of stakes amp protective fencing
Removal of stakes guys ties and protective fencing at the end of the Establishment Period
Once Part of the Final Inspection
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV -
LANDSCAPING
M+ Post Planting Care Plan
Operation Frequency Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
Replacement planting Mar-Sept (as required)
Watering daily
Weeding monthly
Removal of noxious and invasive weeds daily
Apply post-planting fertilizer FebAug
Soil aeration FebAug
Top up mulching 2 times per year
Firming up of tilted plants (as required)
Adjust staking and tying of trees palms monthly
Pruning of trees palms (as required)
Pruning of shrubs and groundcovers (as required)
Training and pruning of climbers adjust climber ties and wires (as required)
Lawn care (as required)
Top dressing for grass areas 2 times per year
Plant division Mar-Sept (as required)
Plant thinning (as required)
Control infestation by rodents etc (as required)
Control pest disease fungal growth and parasitic plants (as required)
Check and repair protective fencing (as required)
Repair typhoon damage (as required)
Clearance of unwanted vegetation (as required)
Removing litter stone rubbish and the like daily
Erosion control (as required)
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX F SUPPLEMENTARY INFORMATION
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
Appendix A ndash M+ Landscape Design Development
Justification of Omission of Tree Line along GF Avenue
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+LandscapeDesignDevelopmentJustificationofOmissionofTreeLineAlongGFAvenue
Appendix A
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+LANDSCAPEDESIGNDEVELOPMENT
INTRODUCTION
The West Kowloon Cultural District Authority and the M+ Joint Venture team genuinely value greenery andlandscape we believe it greatly enriches the architecture and enjoyment of our site and have incorporatedplantingwhereverpossibleWehavealsotothebestofourabilityconformedtothedistrictsrsquoDevelopmentPlan(refertopage4oftheattachedpresentation)originallypublishedin2013andinsomeregardshavegoneaboveandbeyonditsrecommendationsintermsoflandscapingHoweversince2013anumberofenhancementshavebeen made to the architecture planning and landscape design of M+ which now require some necessary andinevitable developments to the original Development Plan In particular the planting of trees along the M+Avenue would be both extremely difficult and detrimental to the functioning of the museum The followingdocumentservestoexplaintheseoperationalprogrammaticandstructuraldifficultiesandalsotoillustratethemeasuresthattheM+teamhastakentomaintainorenhancetheoriginalintentoftheDevelopmentPlan(refertopages2amp3oftheattachedpresentation)
AMUSEUMCLUSTER
The 2013 Development Plan predates the architectural competition for M+ In this original scheme all the M+functionswouldbehousedinonebuildingwhichwouldbeseparatedfromitsneighborsbyatreelinedAvenue(refertoPage5)HoweverthewinningdesignfortheM+competitionproposedgroupingtheM+programsintoacluster of buildings the M+ museum and the Conservation and Storage Facility (CSF) building with the P39Bbuilding providing the supporting retaildiningentertainment functions (refer to page 6) From the very earlystagesofM+planningitrsquosthereforebeencriticalthattheM+CSFandP39Bbuildingsfunctionnotas3separateneighboringentitiesbutasoneclusterandthattheybeclearlyvisuallyandphysicallylinkedForexamplevariousexhibitionsrelatedtotheM+artcollectionwillbestagedintheCSFGFroomsforthepublictoviewTheporousplanofthemuseumrsquosGFandthelargewindowsalongtheCSFandP39Bbuildingshavebeendesignedtoensurethelinkbetweenthem
InordertomaintainthislinkthetreesalongtheAvenuewererelocatedtotwoldquopocketparksrdquoaroundtheCSFandP39BbuildingsThesepocketparkswillbedescribedingreaterdetailfurtheron
EXTENSIONOFARTISTSQUAREINTOTHEM+SITE
Inthe2013DevelopmentPlantheArtistSquarewasclearlydefinedandboundbythebuildingsatitsperimeterShiftingthetreesalongtheM+AvenuetreestotheNorthallowsustoextendtheArtistSquareintooursiteandunderthecanopyoftheM+podiumwhichwillprovideampleshadeinplaceofthetreesaswellasprotectionfromtheelementsTheexpandedArtistSquarespacewillallowthemuseumflexibilityinstagingoutdooreventsorshowsaswellasensurethevisualandphysicalconnectionofthemuseumbuildings(refertopages6amp7)
EXTENSIONOFTHEPARKINTOTHEDISTRICT
TheoriginalDevelopmentPlancreatedaveryclearboundarybetweentheM+siteandtheParkAtGFwithintheM+sitetheprimaryplantedareawastheTreeAvenue
InthecurrentM+schemejustastheArtistSquareextendsintotheM+sitesodoestheParkTheplantedareashavebeenexpandedandinterconnected(refertopages6amp8)
Theproposedpocketparknextto theCSFopenstheParkontotheM+siteandspreadsSouthwardstocreatealushverdantbackdropvisiblefromallpointsoftheM+Avenue(refertopages9amp10)
FurtherconnectingtheParkandM+aretheldquoLearningCenterCourtyardrdquoa24hourpublicallyaccessiblesetofstairswithseatingareasescalatorsliftsandsuspendedplantersandthe3Fpodiumroofterracewithitspublicpathsbenchesshadingstructureandprogrammedareassupportingmuseumfunctions
FromtheParkyouhaveaclearviewtothestepsoftheLearningCentercourtyard(refertopage11)TheLearningCentercourtyardisbothadirectconnectiontotheroofgardenandalsoaplacetositandadmiretheviewfromtheGFSouthterraceBothNorthandSouthwallsof thecourtyardare linedwithcolumns ofverticalplanterswhichenhancethesetting(refertopage12)
The 3F podium roof is planted both on the North and South sides Paved paths carve through the landscapeprovidingHarborviewsandseatingandleadingintolargerspacesforpubliceventseducationandanoutdoorCafespaceAswehaveprovidedashadedpaviliontotheSouthsideandastheM+towershouldprovideshadetotheNorthsidewebelievetheroofgardenwillbeusedyearroundTheroofgardenwillbevisiblefromwithintheM+towerandfromallsurroundingtowersgreatlyenhancingviewswithinthedistrict(refertopage13)
POCKETPARKSANDTHEGREENBELT
As previously noted in order to maintain the link between the M+ CSF amp P39B buildings the trees along theAvenuewererelocatedtotwopocketparksaroundtheCSFandP39BbuildingsTheseparksenrichtheprogramofthesebuildingsarecreateanewenhancedenvironmentthatwasnotplannedforintheinitialDevelopmentPlanTogetherwiththeParktheyformaGreenBeltwhichbuffersthepedestrianareasalongtheAvenuefromtrafficnoiseandpollutioncomingfromtheaccessroadtotheNorth(refertopages8to10)
ThepocketparkbetweentheCSFampP39BbuildingswillbevisiblefromtheAvenueandalsocreateanenhancedenvironmentfortheFampBspaceintheGFofP39BThesuspendedlightingdesignaroundthetreesshouldcreateaveryspecialatmosphereintheevenings(refertopage14)
Along the northern perimeter interplanting of diverse trees forms a thick living wall providing a sense ofenclosureinternallyandvisuallybufferingthelargebuildingstothenorthofthesiteTreeshavebeenselectedfortheirstructuralcharacteristicsEucalyptustereticornisistraditionallyplantedtoformbarriersandgrowstallandstraightveryquicklyIthasfragrantleavesandflowersandlovelybarktextureSterculialanceolataandViburnumodoratissimummayliketheEucalyptusbeplantedintightproximitymakingitidealforformingfencelikestandsTheyhaveanexpressiveandorganichabitandwillgrowoutandawayfromtheEucalyptusflankThisformsthelowercanopyTheunderstoryiscomposedofPolysporaaxillarisandLigustrumsinenseThesearefloweringsmalltree or large shrub with a lush canopy and wide branching habit The species provides immediate screening atplantingandbearsaprofusionofwhiteflowersfromsummertoautumn(refertopage15)
Theclimberspeciesselected for thepocketparksareCampsisgrandifloraandFicuspumilaandshouldalsobevisibleatstreetlevelalongthePIWCarriagewayentrance(refertopage16)
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
REROUTINGOFPIWCARRIAGEWAYROAD
TheoriginalCarriagewaywaslaidoutalongtheWestandSouthsidesoftheM+sitewhichhadtheadvantageofallowingflexibilityinthedesignoftheM+basementandinsettingthebasementrsquoslevels(andthereforefacilitatingAvenuerecessedtreeplanting)However theroadeffectivelycutM+off fromthesurroundingareaDuringthecompetition stage the architects therefore proposed rerouting the Carriageway to create a direct pedestrianconnectionbetweenM+andtheParkampWaterfrontareas(refertopage17)WhilegreatlyimprovingcirculationonthesitethishashadtheeffectofconstrainingthelevelsoftheCarriagewayontheM+site
AELTUNNELCONTRAINTS
ThereroutedCarriagewayroadcrossesdirectlyabovetheMTRAELTunnel(refer topage18) The levelof theCarriageway floor is therefore constrained and could not be lowered without clashing with the tunnel (refer topage19)ThelevelsoftheCarriagewaysoffithavebeensetbytheleveloftheAvenueaboveandbythestructuralamp drainage requirements of the soffit Therefore the structural levels of the Carriageway floor and soffit areessentially fixed allowing the planning team very little flexibility The structural drawing prepared by the M+RegisteredStructuralEngineer(RSE)demonstratesthattheextentoftheAELtunneldirectlyunderneaththeM+structuralhasgovernedthestructurallevelofB1carriageway(refertopage20)
CARRIAGEWAYCLEARHEIGHTCONSTRAINTS
TheB1FCarriagewayrunsdirectlybelowtheGFAvenuethereforeanytreeplantingsalongtheAvenuewoulddirectlyaffectthestructuralloadingandortheclearheightoftheCarriageway
TorecessatreeplanterintheAvenuewhilemaintainingareasonabledistancefromtheM+CSFampP39BbuildingsandavoidingtheEVAtheplanterwouldhavetobeplaceddirectlyaboveeithera)theCarriagewaytrafficlanesorb)thepedestriandropoffarea
a) TheclearheightoftheCarriagewaytrafficlanesisquitetightasisOfthe5700mmclearheightavailable600mmarenecessary forMEPservices leaving just the5100mmclearheight required forCarriagewaytraffic As a recessed planter would reduce the clear height to less than 5100mm it is therefore notpossibletoplacearecessedplanterabovethetrafficlanes(refertopages21amp22)
b) OverthepedestriandropoffareaoftheCarriagewaytheclearheightrequirementislower(only3500mm)Howeverinthisareaitisstructurallyimpossibletorecessaplanterbecauseitwouldcutintothekeyprimarybeam(refertopage26)AgainthestructuraldrawingspreparedbytheRSEindicatethelocationoftherequiredprimarybeamattheGFslabwhichisalreadystretchedtothelimitintermsofdepthandreinforcementcontent(refertopages23to25)
SinceitisnotpossibletorecessatreeeitherovertheCarriagewaytrafficlanesoroverthepedestriandropoffitisthereforenotpossibletorecessaplanteratanypointalongtheM+Avenue
OPERATIONALANDFUNCTIONALCONSTRAINTS
WhileplacingabovegroundplantersontheAvenuewouldbetechnicallypossibletheseplanterswouldneedtobequitelargetoallowthehealthygrowthofatreeAccordingtotheSustainableBuildingDesignGuidelines(APP152)issuedbyBuildingDepartmentstherecommendedminimumsoildepthfortreesare12mInadditiontothesoilrequirement150mmTHKdrainageaggregatewouldbeneededbeneaththesoillayertoavoidwaterloggingAssuch14m(H)planterwouldberequiredtoensurehealthygrowthoftreesSuchlargeabovegroundplanters
wouldbeproblematic foranumberof reasonsAsnotedearlier the3buildings in themuseumclustershouldfunction as one entity with the Artist Square extending into the site Aboveground planters would defeat thefundamentaldesignprinciplesofM+byvisuallyandphysicallydisconnectingtheCSFandP39BbuildingsfromM+andfromtheArtistSquarereducingflexibilityinstagingoutdooreventsorshowsconcealingmuseumsignageand impeding site maintenance and museum access among other things (refer topage27) Therefore abovegroundplantersarestronglyopposed
CONCLUSION
Webelieveourproposal(refertopage28)toshifttheAvenuetreestothenorthernGreenBeltisnecessaryandjustifiableand togetherwiththecreationofvibrantpocketparksaswellas theLearningCenterCourtyardandpodiumroofgardenrepresentsagenuineimprovementoftheoriginalDevelopmentPlangoingevenfurtherthanoriginallyanticipatedinprovidingpublicallyaccessibleplantedspacesalongtheAvenueandthedistrictrsquosgroundlevel
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
2
-+ ~
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017
M+ IN CONTEXTM+ LANDSCAPE
IMAGE CREDIT AND SOURCE DLNWEST8
3
-+ ~
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017WKCD DEVELOPMENT PLAN - LANDSCAPE CONCEPT - 812013
M+ LANDSCAPE4
-+ ~
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
TREE-LINED AVENUE
M+ Consultancy JV - 08062017 M+ LANDSCAPE
M+
TREE-LINED AVENUEARTIST SQUARE
WKCD DEVELOPMENT PLAN - M+ AND ARTISTS SQUARE
PARK
25mAVENUE SECTION
13 TREES ALONG AVENUE
5
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
45m
GREEN BELT
M+ Consultancy JV - 08062017
CURRENT SITE PLANM+ LANDSCAPE
PARK
13 AVENUE TREES ARE KEPT AND RELOCATED
TO GREEN AREA SURROUNDING CSF
SUPPLEMENTED WITH 35 TALL SHRUBS
HARD PAVED AND ILLUMINATED AREA
BETWEEN CSF AND M+ FOR CAFE SEATING AND
PUBLIC ENJOYMENT
ARTIST SQUARE EXTENDED INTO M+ SITE TO MAINTAIN PHYSICAL AND VISUAL CONNECTION BETWEEN M+ CSF AND P39B
PARK EXTENDED INTO M+ SITE
AVENUE SECTION
BUILDING CANOPY PROVIDES ABUNDANT
SHADE IN PLACE OF TREES
ARTIST SQUARE
LYRIC THEATER
ARTI
ST S
QU
ARE
BRID
GE
CSF
M+
P39B
TREE-LINED AVENUE
6
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE EASTM+ LANDSCAPE
7
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017
GREEN BELT AND GREEN ROOFM+ LANDSCAPE
WATERFRONT PROMENADE
ARTIST SQUARE
GREEN BELT
M+ GREEN ROOF LYRIC THEATER
CSF
P39B
LEARNING CENTER COURTYARD
8
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017
VIEW WEST ALONG THE AVENUEM+ LANDSCAPE
9
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017
AVENUE VIEW FROM THE PARKM+ LANDSCAPE
10
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
LEARNING CENTER COURTYARD A DIRECT amp PUBLIC GREEN CONNECTION BETWEEN THE PARK AND M+ ROOF TERRACE GARDEN
M+ Consultancy JV - 08062017
M+ VIEWED FROM THE PARKM+ LANDSCAPE
11
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
VIEW OF LEARNING CENTER COURTYARD FROM PARK
SECTION THROUGH LEARNING CENTER COURTYARD
COVERED ESCALATOR TO M+ ROOF TERRACE GARDEN
PARKLEARNING CENTRE
GALLERY
COURTYARD MOUND
COURTYARDCOURTYARD
TERRACE GARDEN
GALLERYGALLERY
M+ Consultancy JV - 08062017M+ LEARNING CENTER COURTYARD
M+ LANDSCAPE12
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
PATHS AND BENCHES IN ROOF TERRACE GARDEN
SHADING STRUCTURE IN SOUTH ROOF TERRACE GARDENVIEW TO ROOF TERRACE GARDEN FROM CAFE
NORTH ROOF TERRACE GARDEN WITH VIEWS TO THE CSF P39B ICC
M+ Consultancy JV - 08062017M+ PODIUM ROOF TERRACE GARDEN
M+ LANDSCAPE13
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017
POCKET PARK AT CSF amp P39BM+ LANDSCAPE
IC GE JHFD
UP
UP
1072
1
7435
1106
2
8058
1200 1200
8313
1070
0
611
1757
3104
5303
9877
Et (h)
Et (h)
Et (l)
Vod
VodSla
Sla
Et (l)
Et (l)
VIEW FROM P39B 1F WINDOW
GF VIEW FROM THE NORTH
CSF P39B
14
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017 M+ LANDSCAPE
VIEW FROM NORTH PERIMETER ROAD16
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+
Park
13
M+
Park
13
M+ Consultancy JV - 08062017
UNDERGROUND ROAD IN DP- M+ largely inaccessible from the Park due to the underpass road
CURRENT UNDERGROUND ROAD GAZETTED AND UNDER CONSTRUCTION- The public can walk directly between the M+ Museum and the Park
M+ LANDSCAPE
WKCD UNDERPASS ROAD17
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
6400
EXISTING MTR AEL TUNNEL UNDERNEATH B1F
CARRIAGEWAY CROSSES OVER MTR AEL TUNNEL THIS SETS THE LEVELS OF CARRIAGEWAY WHICH CANNOT BE MODIFIED
+6300mPD (B1F Level)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LEVEL CONSTRAINTS AT B1F
+12700mPD (GF Level)
19
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH B1F20
Extent of AEL Tunnelunderneath M+ structurewhich govern the structurallevels of B1 slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT REQUIREMENTS
131313 13 1313
13
1313
13 13
13
$ 13 131313 13
lt=gt [
lt$gt ]
131313 13 13^ 13
_`jqz |^|
[ |~ |] `|q|| |
21
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
GF AVENUE PLAN1500
GF AVENUE SECTION1200
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY CLEAR HEIGHT CONSTRAINTS
NOT FEASIBLE DUE TO CLEAR HEIGHT REQUIREMENTSIN CARRIAGEWAY
lt 51m min
CSF
CSF P39B
M+
22
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - NORTH GF23
Key primary beam at GF slab
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL PLANS - SOUTH GF24
Key primary beam at GF slab(B1 ceiling soffit)
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017 M+ LANDSCAPE
CARRIAGEWAY STRUCTURAL SECTION25
Key primary beamat GF slab
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
walkway
M+ Consultancy JV - 08062017 M+ LANDSCAPE
STRUCTURAL LOADING CONSTRAINTS
TREE PITS OVER B1 COLUMNS AND BEAM
HOWEVER TREE PITS LOCATED DIRECTLY ABOVE COLUMNSBEAMS ARE NOT FEASIBLE STRUCTURALLY
GF AVENUE PLAN1500
GF AVENUE SECTION1200
AT PEDESTRIAN WALKWAY CLEAR HEIGHT REQUIREMENT IS AT ITS LOWEST (35m)
35m min
CSF
CSF P39B
M+
26
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017 M+ LANDSCAPE
MUSEUM OPERATION
ABOVE-GROUND PLANTERS WOULD BE LARGE AND HEAVY IMPEDING SITE MAINTENANCE
AND MUSEUM ACCESS
TREES AND PLANTERS REDUCE FLEXIBILITY WHEN USING
OUTDOOR SPACE FOR EVENTS AND DISPLAYING ARTWORK
TREES AND PLANTERS OBSTRUCT VISIBILITY
OF MUSEUM SIGNAGE DISPLAYS AND ACCESS
OUTDOOR EXHIBITION AREA OUTDOOR EXHIBITION AREA
NOT FEASIBLE OPERATIONALLY
14m min
17m min
M+ CSF
27
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - 08062017
M+ GREENERY PROVISIONM+ LANDSCAPE
CURRENT M+ LANDSCAPEM+ LANDSCAPE PER WKCD DEVELOPMENT PLANIMAGE CREDIT AND SOURCE DLNWEST8
28
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX G IMPLEMENTATION PROGRAMME Drawing no- Description
XXXXX-AUT-LAN-DWG-2371-P00-XXXX-WSX Tree and Turf Grass Planting and Landscape Plan Overall Master Plan
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
M+ Consultancy JV - Submission of Tree and Turf Grass Planting and Landscape Plans
APPENDIX H CONDITION OF APPROVAL UNDER SECTION 8 (3) OF THE EIA ORDINANCE
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- 1 OBJECTIVE AND PURPOSE OF THE REPORT
-
- 111 Further to the approval of the Environmental Impact Assessment (EIA) Report in the register (AEIAR-1782013) the project proponent is required to submit the Tree and Turf Grass Planting and Landscape Plan to comply with the Condition of Approva
- 112 Revision B of this report under report ref 3AXXX-TFP-LAN-REP-0001-LMP-WS2-XB was submitted on 18 Nov 2014 Subsequent comments on the submitted report were received from Planning Department dated 06 July 2015 and Revision C Report was made on
- 113 Comments from PlanD on Revision C Report was received on 23 September 2015 and comments are addressed in this Revision D and responses to comments are attached in Appendix E for further review
-
- 2 INTRODUCTION
-
- 211 The West Kowloon Cultural District Authority (named ldquoAuthorityrdquo hereafter) is invested by the Government of the Hong Kong Special Administrative Region to meet the long term infrastructure needs of the arts and cultural sector which is a vital
-
- i) Planning design and construction of 17 core arts and cultural facilities (CACF) (comprising 15 performing arts venues a cultural institution with museum functions (M+) together with its off-site conservatory laboratory and storage facilities and
- ii) Planning of the WKCD and project management which include consultancies technical studies and public consultations for the preparation of a development plan for the whole WKCD site and project management during the planning and construction stage
- iii) Major repair and renovation of the facilities and
- iv) Collection exhibition development conservation laboratory equipment and library setup for the M+
-
- 212 M+ Consultancy JV (MJV) was appointed as the consultant for the Design and Administration of the Construction of M+ (Phase 1) for the West Kowloon Cultural District Authority on 16 July 2013
-
- 3 Landscape Tree and planting plan
-
- 31 Ground Floor and B1 Floor
-
- 311 Along the northern perimeter inter-planting of diverse trees forms a thick living wall providing a sense of enclosure internally and visually buffering the large buildings to the north of the site Specific placement of the trees is dependent
- 312 Behind the tree planting climbing vines Campsis grandiflora and Ficus pumila are planted to effectively cover the boundary fence These species are quick and vigorous growers perform well in variety of conditions and are particularly amenabl
- 313 Not used
- 314 The tightly planted tree clusters along the waterfront promenade control and enhance view-sheds from the M+ Museum to the waterfront The groups are formed of Terminalia mantaly evergreen trees which provide shade screen winds and loosely def
- 315 In both the North and the South trees are to be planted at different calibers and heights even within the species group This helps to more closely mimic the natural variation of mature stands of trees and more quickly naturalizes the appeara
- 316 The required built-up for the lawn is a minimum of 030 metres and for trees 120 metres The trees should be of heavy standard size when being planted and again planted at a variety of heights ages and calibres Especially next to the high
- 317 In the current design as shown in Appendix C the green area at pedestrian zone provided for the B1 floor and Ground floor are approx 198 m2 and 989 m2 respectively ( refer to Table A)
- 318 The percentage of the native tree to be planted in the ground floor and B1 floor in terms of total quantity number are 375 ( 6 number out of 16 number are native species) ( refer to Table B and )
-
- 32 3 Floor Podium Roof
-
- 321 On the roof slabs of concrete are divided by long joints Built into the strict geometry of the concrete are curvilinear biomorphic planting fields Slender paths wind around and through these organically shaped planting zones carving out a r
- 322 There is general gradient in height from the Northern edge to the Southern face moving smoothly between 20 meters down to 01 meters in the South Additionally within each zone plants are arranged by height and foliage colour building a cade
- 323 Proposed shrub planting is to be planted on an informal grid Plants are to be planted in groups of the same species (group size of at least 20-30 plants) according to the percentages in the provided plan of the Podium Roof The flowering cycles
- 324 For the shrub and ground cover planting plan and planting schedule for the 3 floor podium roof please refer to drawing no 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4 3A40X-TFP-LAN-DWG-0523-P00-L003-WS43A40X-TFP-L
- 325 Greening coverage for the 3 floor podium roof is approx 7336 m2 as illustrated in Appendix C and summarized in Table A
- Table A ndash Greening Coverage Summary Table
-
- 4 Post Planting Care plan
-
- 411 It is anticipated that proposed landscape works would be implemented in year 2020 (refer to Appendix G)
- 412 Routine maintenance operations for the landscape works iepost planting care plan are provided in Appendix D
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-
- Binder1pdf
-
- 3A39A-TFP-LAN-DWG-0501-P01-L000-WS4-06_20190318
- 3A39A-TFP-LAN-DWG-0502-P01-L000-WS4-06_20190318
- 3A40X-TFP-LAN-DWG-0521-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0522-P00-L003-WS4-02
- 3A40X-TFP-LAN-DWG-0523-P00-L003-WS4-04
-
- Sheets and Views
-
- Layout
-
- 3A40X-TFP-LAN-DWG-0524-P00-L003-WS4-03
- 3A40X-TFP-LAN-DWG-0551-P00-L003-WS4-00
- 3AXXX-TFP-LAN-DWG-0507-P00-LB01-WS4-02_20190318
- 3AXXX-TFP-LAN-DWG-0508-P00-LB01-WS4-02_20190318
-