Projeto Lumière - GEOCITIES.ws

48
Projeto Lumière Sala Lumière Date: 02-06-2002 Customer: Revista Lumière Designer: Wilson Teixeira Description: Projeto para avaliação/demonstração do software CALCULUX INDOOR 4.5b CalcuLuX Indoor 4.5b E-Mail: [email protected] Fax: (21) 2565-7847 Telephone: (21) 2565-7847 Caixa Postal 24165 20522-970 Rio de Janeiro BRAZIL W. Teixeira The nominal values shown in this report are the result of precision calculations, based upon precisely positioned luminaires in a fixed relationship to each other and to the area under examination. In practice the values may vary due to tolerances on luminaires, luminaire positioning, reflection properties and electrical supply.

Transcript of Projeto Lumière - GEOCITIES.ws

Projeto Lumière

Sala LumièreDate: 02-06-2002Customer: Revista Lumière

Designer: Wilson Teixeira

Description: Projeto para avaliação/demonstração do software CALCULUX INDOOR 4.5b

CalcuLuX Indoor 4.5b E-Mail: [email protected]: (21) 2565-7847Telephone: (21) 2565-7847

Caixa Postal 2416520522-970Rio de JaneiroBRAZIL

W. Teixeira

The nominal values shown in this report are the result of precision calculations, based upon precisely positioned luminaires in a fixed relationship to each other and to the area under examination. In practice the values may vary due to tolerances on luminaires, luminaire positioning, reflection properties and electrical supply.

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

Table of Contents

1. Project Description 4

1.1 3-D Project Overview 41.2 Top Project Overview 51.3 Left Project Overview 61.4 Right Project Overview 71.5 Front Project Overview 81.6 Back Project Overview 9

2. Summary 10

2.1 Room Summary 102.2 Project Luminaires 102.3 Calculation Results 10

3. Calculation Results 11

3.1 Grid: Textual Table 113.2 Grid: Graphical Table 123.3 Grid: Iso Contour 133.4 Grid: Filled Iso Contour 143.5 Grid: Mountain Plot 153.6 Mesa3: Textual Table 163.7 Mesa3: Graphical Table 173.8 Mesa3: Iso Contour 183.9 Mesa3: Filled Iso Contour 193.10 Mesa3: Mountain Plot 203.11 Mesa2: Textual Table 213.12 Mesa2: Graphical Table 223.13 Mesa2: Iso Contour 233.14 Mesa2: Filled Iso Contour 243.15 Mesa2: Mountain Plot 253.16 Mesa1: Textual Table 263.17 Mesa1: Graphical Table 273.18 Mesa1: Iso Contour 283.19 Mesa1: Filled Iso Contour 293.20 Mesa1: Mountain Plot 303.21 Mesa1a: Textual Table 313.22 Mesa1a: Graphical Table 323.23 Mesa1a: Iso Contour 333.24 Mesa1a: Filled Iso Contour 343.25 Mesa1a: Mountain Plot 353.26 Mesa1a1: Textual Table 363.27 Mesa1a1: Graphical Table 373.28 Mesa1a1: Iso Contour 383.29 Mesa1a1: Filled Iso Contour 393.30 Mesa1a1: Mountain Plot 403.31 Mesa1a2: Textual Table 413.32 Mesa1a2: Graphical Table 423.33 Mesa1a2: Iso Contour 433.34 Mesa1a2: Filled Iso Contour 443.35 Mesa1a2: Mountain Plot 45

4. Luminaire Details 46

4.1 Project Luminaires 46

5. Installation Data 47

5.1 Legends 475.2 Luminaire Positioning and Orientation 47

6. Financial Information 48

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 2/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

6.1 Installation Data 486.2 Luminaire Information 486.3 Total cost 48

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 3/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

1. Project Description

1.1 3-D Project Overview

4.00 mLength

6.00 mWidth Height

2.80 mWorking Plane Height

0.80 m

A Fluorescente de embutir Refletor branco

AA

AA

X

Y

Z

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 4/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

1.2 Top Project Overview

4.00 mLength

6.00 mWidth Height

2.80 mWorking Plane Height

0.80 m

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-2-1

01

23

45

6

Y(m

)

AA

AA

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 5/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

1.3 Left Project Overview

4.00 mLength

6.00 mWidth Height

2.80 mWorking Plane Height

0.80 m

A Fluorescente de embutir Refletor branco

4.2 3.7 3.2 2.7 2.2 1.7 1.2 0.7 0.2

Y(m)

-1-0

.50

0.5

11.

52

2.5

33.

5

Z(m

)

AA AA

Scale1:25

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 6/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

1.4 Right Project Overview

4.00 mLength

6.00 mWidth Height

2.80 mWorking Plane Height

0.80 m

A Fluorescente de embutir Refletor branco

-0.2 0.3 0.8 1.3 1.8 2.3 2.8 3.3 3.8

Y(m)

-1-0

.50

0.5

11.

52

2.5

33.

5

Z(m

)

AAAA

Scale1:25

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 7/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

1.5 Front Project Overview

4.00 mLength

6.00 mWidth Height

2.80 mWorking Plane Height

0.80 m

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-2.5

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

Z(m

)

AA AA

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 8/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

1.6 Back Project Overview

4.00 mLength

6.00 mWidth Height

2.80 mWorking Plane Height

0.80 m

A Fluorescente de embutir Refletor branco

6.5 5.5 4.5 3.5 2.5 1.5 0.5

X(m)

-2.5

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

Z(m

)

A AA A

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 9/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

2. Summary

2.1 Room Summary

Room DimensionsWidth 6.00 mLength 4.00 mHeight 2.80 mWorking Plane Height 0.80 m

Surface ReflectanceCeiling 0.70Left Wall 0.50Right Wall 0.50Front Wall 0.50Back Wall 0.50Floor 0.20

Room Position (Front Bottom Left)X 0.00 mY 0.00 m

Total Average Room Surface Luminance (cd/m2):Ceiling

30.7

LeftLeft

52.8

RightRight

52.8

FrontFront

51.3

BackBack

51.3

FloorFloor

26.6

Unified Glare Rating (CIE): 21

The overall maintenance factor used for this project is 1.00.

2.2 Project Luminaires

Code

A

QtyQty

4

Luminaire TypeLuminaire Type

Fluorescente de embutir Refletor branco

Lamp TypeLamp Type

2 * Fluorescente 36W

Power (W)Power (W)

64.0

Flux (lm)Flux (lm)

2 * 2700

The total installed power: 0.26 (kWatt)

Number of Luminaires Per Arrangement:

Arrangement

Room Block

LuminaireCode

A4

Power (kWatt)Power (kWatt)

0.26

2.3 Calculation Results

(Il)luminance Calculations:Calculation

GridMesa3Mesa2Mesa1Mesa1aMesa1a1Mesa1a2

TypeType

Surface IlluminanceSurface IlluminanceSurface IlluminanceSurface IlluminanceSurface IlluminanceSurface IlluminanceSurface Illuminance

UnitUnit

luxluxluxluxluxluxlux

AveAve

519 467 594 593 431 494 479

Min/AveMin/Ave

0.690.800.920.910.750.860.78

Min/MaxMin/Max

0.590.700.900.890.600.760.66

ResultResult

TotalTotalTotalTotalTotalTotalTotal

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 10/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3. Calculation Results

3.1 Grid: Textual Table

Grid : Grid at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 519 0.69 0.59 1.00

X (m) 0.25 0.75 1.25 1.75 2.25 2.75 3.25 3.75 4.25 4.75 5.25 5.75 Y (m) 3.75 357< 413 460 481 479 470 470 479 481 460 413 357<

3.25 410 484 541 565 559 544 544 559 565 541 484 410

2.75 443 520 579 605 600 585 585 600 605 579 520 443

2.25 450 526 581 607> 607 595 595 607 607 581 526 450

1.75 450 526 581 607> 607 595 595 607 607> 581 526 450

1.25 443 520 579 605 600 585 585 600 605 579 520 443

0.75 410 484 541 565 559 544 544 559 565 541 484 410

0.25 357< 413 460 481 479 470 470 479 481 460 413 357<

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 11/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.2 Grid: Graphical Table

Grid : Grid at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 519 0.69 0.59 1.00

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

5.5

Y(m

)

A A

A A

357

410

443

450

450

443

410

357

413

484

520

526

526

520

484

413

460

541

579

581

581

579

541

460

481

565

605

607

607

605

565

481

479

559

600

607

607

600

559

479

470

544

585

595

595

585

544

470

470

544

585

595

595

585

544

470

479

559

600

607

607

600

559

479

481

565

605

607

607

605

565

481

460

541

579

581

581

579

541

460

413

484

520

526

526

520

484

413

357

410

443

450

450

443

410

357

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 12/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.3 Grid: Iso Contour

Grid : Grid at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 519 0.69 0.59 1.00

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

5.5

Y(m

)

A A

A A

400

400

400

400

450

450

450

450

500

500

500

500

550

550

550

600 600

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 13/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.4 Grid: Filled Iso Contour

Grid : Grid at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 519 0.69 0.59 1.00

A Fluorescente de embutir Refletor branco

600

550

500

450

400

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-0.5

0.5

1.5

2.5

3.5

4.5

Y(m

)

A A

A A

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 14/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.5 Grid: Mountain Plot

Grid : Grid at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 519 0.69 0.59 1.00

0

1

2

3

4

5

6

X(m)

0

1

2

3

4

Y(m)

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 15/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.6 Mesa3: Textual Table

Grid : Mesa3 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 467 0.80 0.70 1.00

X (m) 5.20 5.35 5.50 5.65 5.80 5.95 Y (m) 3.20 496 475 454 431 406 372<

3.04 512 491 469 445 420 385

2.87 522 500 478 455 430 396

2.70 528 507 484 460 436 401

2.54 532 510 488 464 439 404

2.37 532> 512 490 466 441 406

2.21 532 512 490 467 442 407

2.04 532 512 490 467 442 407

1.88 532 512 490 467 442 407

1.71 532 512 490 467 442 406

1.55 511 489 466 440 405

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 16/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.7 Mesa3: Graphical Table

Grid : Mesa3 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 467 0.80 0.70 1.00

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

5.5

Y(m

)

A A

A A

372

385

396

401

404

406

407

407

407

406

405

406

420

430

436

439

441

442

442

442

442

440

431

445

455

460

464

466

467

467

467

467

466

454

469

478

484

488

490

490

490

490

490

489

475

491

500

507

510

512

512

512

512

512

511

496

512

522

528

532

532

532

532

532

532

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 17/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.8 Mesa3: Iso Contour

Grid : Mesa3 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 467 0.80 0.70 1.00

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

5.5

Y(m

)

A A

A A

375400

425

450

475500

525

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 18/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.9 Mesa3: Filled Iso Contour

Grid : Mesa3 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 467 0.80 0.70 1.00

A Fluorescente de embutir Refletor branco

525

500

475

450

425

400

375

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-0.5

0.5

1.5

2.5

3.5

4.5

Y(m

)

A A

A A

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 19/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.10 Mesa3: Mountain Plot

Grid : Mesa3 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 467 0.80 0.70 1.00

5

5.2

5.4

5.6

5.8

6

X(m)

1.4

1.6

1.8

2

2.2

2.4

2.6

2.8

3

3.2

Y(m)

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 20/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.11 Mesa2: Textual Table

Grid : Mesa2 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 594 0.92 0.90 1.00

X (m) 3.20 3.35 3.50 3.65 3.80 3.95 Y (m) 3.20 550< 553 557 562 567 571

3.04 569 572 576 581 585 588

2.87 579 583 587 592 596 600

2.70 586 589 594 598 603 607

2.54 590 594 598 603 607 609

2.37 593 596 600 604 608 610

2.21 594 597 600 605 608 610

2.04 594 597 601 605 608 609

1.88 594 597 601 605 608 610

1.71 593 597 600 604 608 610>

1.55 595 599 604 608 610

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 21/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.12 Mesa2: Graphical Table

Grid : Mesa2 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 594 0.92 0.90 1.00

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

5.5

Y(m

)

A A

A A

571

588

600

607

609

610

610

609

610

610

610

567

585

596

603

607

608

608

608

608

608

608

562

581

592

598

603

604

605

605

605

604

604

557

576

587

594

598

600

600

601

601

600

599

553

572

583

589

594

596

597

597

597

597

595

550

569

579

586

590

593

594

594

594

593

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 22/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.13 Mesa2: Iso Contour

Grid : Mesa2 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 594 0.92 0.90 1.00

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

5.5

Y(m

)

A A

A A

560570

580

590

600

610

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 23/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.14 Mesa2: Filled Iso Contour

Grid : Mesa2 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 594 0.92 0.90 1.00

A Fluorescente de embutir Refletor branco

610

600

590

580

570

560

550

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-0.5

0.5

1.5

2.5

3.5

4.5

Y(m

)

A A

A A

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 24/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.15 Mesa2: Mountain Plot

Grid : Mesa2 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 594 0.92 0.90 1.00

3

3.2

3.4

3.6

3.8

4

X(m)

1.4

1.6

1.8

2

2.2

2.4

2.6

2.8

3

3.2

Y(m)

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 25/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.16 Mesa1: Textual Table

Grid : Mesa1 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 593 0.91 0.89 1.00

X (m) 1.20 1.35 1.50 1.65 1.80 1.95 Y (m) 3.20 542< 556 565 570 572 572

3.04 559 572 582 587 590 589

2.87 570 583 593 599 600 601

2.70 575 591 601 606 606 608

2.54 577 593 603 608 608 610

2.37 577 592 602 607 608 610

2.21 575 590 601 606 606 610

2.04 574 589 600 605 605 608

1.88 575 590 600 605 606 609

1.71 576 591 601 607 607 610

1.55 592 602 608 608 610>

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 26/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.17 Mesa1: Graphical Table

Grid : Mesa1 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 593 0.91 0.89 1.00

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

5.5

Y(m

)

A A

A A

572

589

601

608

610

610

610

608

609

610

610

572

590

600

606

608

608

606

605

606

607

608

570

587

599

606

608

607

606

605

605

607

608

565

582

593

601

603

602

601

600

600

601

602

556

572

583

591

593

592

590

589

590

591

592

542

559

570

575

577

577

575

574

575

576

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 27/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.18 Mesa1: Iso Contour

Grid : Mesa1 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 593 0.91 0.89 1.00

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

5.5

Y(m

)

A A

A A

550

560

570

580 590

600

610

610

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 28/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.19 Mesa1: Filled Iso Contour

Grid : Mesa1 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 593 0.91 0.89 1.00

A Fluorescente de embutir Refletor branco

610

600

590

580

570

560

550

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-0.5

0.5

1.5

2.5

3.5

4.5

Y(m

)

A A

A A

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 29/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.20 Mesa1: Mountain Plot

Grid : Mesa1 at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 593 0.91 0.89 1.00

1

1.2

1.4

1.6

1.8

2

X(m)

1.4

1.6

1.8

2

2.2

2.4

2.6

2.8

3

3.2

Y(m)

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 30/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.21 Mesa1a: Textual Table

Grid : Mesa1a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 431 0.75 0.60 1.00

X (m) 0.25 0.41 0.57 0.73 0.88 1.04 1.20 Y (m) 3.95 323< 339 353 367 380 396 406

3.76 356 374 391 408 425 441 453

3.58 378 399 419 439 458 474 487

3.39 397 421 443 464 485 503 517

3.20 440 463 486 508 527 542>

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 31/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.22 Mesa1a: Graphical Table

Grid : Mesa1a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 431 0.75 0.60 1.00

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

5.5

Y(m

)

A A

A A

406

453

487

517

542

396

441

474

503

527

380

425

458

485

508

367

408

439

464

486

353

391

419

443

463

339

374

399

421

440

323

356

378

397

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 32/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.23 Mesa1a: Iso Contour

Grid : Mesa1a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 431 0.75 0.60 1.00

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

5.5

Y(m

)

A A

A A

350

400

450

500

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 33/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.24 Mesa1a: Filled Iso Contour

Grid : Mesa1a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 431 0.75 0.60 1.00

A Fluorescente de embutir Refletor branco

500

450

400

350

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-0.5

0.5

1.5

2.5

3.5

4.5

Y(m

)

A A

A A

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 34/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.25 Mesa1a: Mountain Plot

Grid : Mesa1a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 431 0.75 0.60 1.00

0.2

0.4

0.6

0.8

1

1.2

X(m)

3

3.2

3.4

3.6

3.8

4

Y(m)

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 35/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.26 Mesa1a1: Textual Table

Grid : Mesa2a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 494 0.86 0.76 1.00

X (m) 2.25 2.41 2.57 2.73 2.88 3.04 3.20 Y (m) 3.95 432 430 429 427 426 426< 426

3.76 477 474 471 468 467 466 467

3.58 511 507 502 499 497 496 498

3.39 540 535 531 526 524 523 525

3.20 560> 555 551 548 547 550

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 36/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.27 Mesa1a1: Graphical Table

Grid : Mesa2a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 494 0.86 0.76 1.00

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

5.5

Y(m

)

A A

A A

426

467

498

525

550

426

466

496

523

547

426

467

497

524

548

427

468

499

526

551

429

471

502

531

555

430

474

507

535

560

432

477

511

540

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 37/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.28 Mesa1a1: Iso Contour

Grid : Mesa2a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 494 0.86 0.76 1.00

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

5.5

Y(m

)

A A

A A

450

475

500

525

550

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 38/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.29 Mesa1a1: Filled Iso Contour

Grid : Mesa2a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 494 0.86 0.76 1.00

A Fluorescente de embutir Refletor branco

550

525

500

475

450

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-0.5

0.5

1.5

2.5

3.5

4.5

Y(m

)

A A

A A

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 39/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.30 Mesa1a1: Mountain Plot

Grid : Mesa2a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 494 0.86 0.76 1.00

2.2

2.4

2.6

2.8

3

3.2

X(m)

3

3.2

3.4

3.6

3.8

4

Y(m)

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 40/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.31 Mesa1a2: Textual Table

Grid : Mesa3a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 479 0.78 0.66 1.00

X (m) 4.25 4.41 4.57 4.72 4.88 5.04 5.20 Y (m) 3.95 427 425 420 411 402 387 373<

3.76 478 476 470 460 448 433 416

3.58 514 512 506 494 481 466 448

3.39 545 543 537 525 510 494 474

3.20 569> 562 549 535 518 496

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 41/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.32 Mesa1a2: Graphical Table

Grid : Mesa3a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 479 0.78 0.66 1.00

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

5.5

Y(m

)

A A

A A

373

416

448

474

496

387

433

466

494

518

402

448

481

510

535

411

460

494

525

549

420

470

506

537

562

425

476

512

543

569

427

478

514

545

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 42/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.33 Mesa1a2: Iso Contour

Grid : Mesa3a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 479 0.78 0.66 1.00

A Fluorescente de embutir Refletor branco

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-1.5

-0.5

0.5

1.5

2.5

3.5

4.5

5.5

Y(m

)

A A

A A

400450

500

550

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 43/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.34 Mesa1a2: Filled Iso Contour

Grid : Mesa3a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 479 0.78 0.66 1.00

A Fluorescente de embutir Refletor branco

550

500

450

400

-0.5 0.5 1.5 2.5 3.5 4.5 5.5

X(m)

-0.5

0.5

1.5

2.5

3.5

4.5

Y(m

)

A A

A A

Scale1:40

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 44/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

3.35 Mesa1a2: Mountain Plot

Grid : Mesa3a at Z = 0.80 mCalculation : Surface Illuminance (lux)Result Type : Total

Average Min/Ave Min/Max Project maintenance factor 479 0.78 0.66 1.00

4.2

4.4

4.6

4.8

5

5.2

X(m)

3

3.2

3.4

3.6

3.8

4

Y(m)

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 45/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

4. Luminaire Details

4.1 Project Luminaires

Fluorescente de embutir Refletor branco 2 x Fluorescente 36W

Light output ratios DLOR : 0.83 ULOR : 0.00 TLOR : 0.83Ballast : EletrônicoLamp flux : 2700 lmLuminaire wattage : 64.0 W

Note: Luminaire data not from database.

200

0o 30o30o

60o 60o

90o 90o

120o 120o150o 150o180o

C = 180o C = 0o

C = 270o Imax C = 90o

Luminous Intensity Diagram (candela/1000 lumen)

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 46/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

5. Installation Data

5.1 Legends

Project Luminaires:Code

A

QtyQty

4

Luminaire TypeLuminaire Type

Fluorescente de embutir Refletor branco

Lamp TypeLamp Type

2 * Fluorescente 36W

Flux (lm)Flux (lm)

2 * 2700

5.2 Luminaire Positioning and Orientation

Qty and Code

1 * A1 * A1 * A1 * A

X (m)

1.50 1.50 4.50 4.50

Y (m)

1.00 3.00 1.00 3.00

Position

Z (m)

2.80 2.80 2.80 2.80

Rot.

0.00 0.00 0.00 0.00

Tilt90

0.00 0.00 0.00 0.00

Aiming Angles

Tilt0

0.00 0.00 0.00 0.00

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 47/48

Projeto Lumière W. TeixeiraSala Lumière Date: 02-06-2002

6. Financial Information

6.1 Installation Data

Burning hours/year hr 0Amortization period yr1.0Interest rate %0.0kWh price 0.00

6.2 Luminaire Information

Project Luminaires

Fluorescente de embutir Refletorbranco

QtyQty

4

Lamp

0.00

Luminaire

0.00

Installation

0.00

Prices ()

Maintenance

0.00

Relampingperiod (yr)Relampingperiod (yr)

1.00

6.3 Total cost

Costs per yearEnergy 0.00Investment 0.00Lamps 0.00Maintenance 0.00

-------------Total 0.00

Total investment 0.00

CalcuLuX Indoor 4.5b Philips Lighting B.V. Page: 48/48