PERMIT DATA FOR PERMIT APPLICATION 1246826
The work category of your project is Potable Water
in DeKalb County/Counties
TPro Project ID 0013333
Location Information
The Utility installation location was narrowed down to
Beginning Mile Point 0.62 and Ending Mile Point 1.03
on Route No 040200
General Encroachment Information
Traffic Control type is MUTCD Part 6 - Typical Application Plan
Traffic Control Plan Upload
Utility Information
Work
description
Proposed water facilities relocation work includes the following: adjust one
fire hydrant, adjust one water meter box, abandon one water valve, adjust
one water valve. install one water meter and box, install one 6in gate valve,
install four 8in valves, install one fire hydrant
Work days estimate 51 Bridge and Wall Attachments No
Facility Placement Type Both Installation Length 1372.8
Facility Type Distribution Service Type Both
Pipe Size 8 Pipe Material DIP
Pressure 250 Casing Material None
Casing Diameter 0.0 Valve Quantity 0
Main Type Pressure
Manhole Quantity 0 Handhole Quantity 0
Minimum Depth 4 Maximum Depth 5
Number of Test Holes 0 Involves Pavement Cutting Yes
Joint Trench No Underground
Construction
Type(s)
Trench ,Open
Cut
Number of
Lanes
1
Pavement Cut
Size
4155 Pavement Cut
Type
Crossing Drawings
Upload
Upload #
1 File Name EURI.pdf File
Description
Other
Information
Upload #
2 File Name PLANS.pdf File
Description
Permit Plans Upload #
3 File Name No cost
Letter.pdf
File
Description
Other
Information
Upload #
4 File Name NPDES
Compliance
Statement.pdf
File
Description
Other
Information
Blasting
Information
Blasting
Required is
No.
General
Utility
Adjustment
Schedule
Plan Date Jul 23, 2021 Project
Number
0013333
Schedule Type Original Facility
Identificatio
n
Subsurface
investigation
(SUE)
Special
Requirements
The work
noted in this
schedule will
be performed
by GDOT
Contractor,
schedule for
roadway and
pedestrian
improvements.
GDOTs
Contractor to
provide at
least four-
week advance
notice of
work in areas
identified
for COA
relocations.
Plan Type Original Cost Borne By Utility Owner Cost Approval
Status
Pending
Existing
Utility
Details: # 1
Service
Provided
Adjust Water
Meter Box to
Grade
Quantity 1 Unit
EA Existing
Utility
Details: # 2
Service
Provided
Adjust Water
Valve Box to
Grade
Quantity 1
Unit EA Existing
Utility
Details: # 3
Service
Provided
Adjust Fire
Hydrant to
Grade
Quantity
1 Unit EA Existing
Utility
Details: # 4
Service
Provided
Install Water
Main, 6-inch
Quantity 26 Unit LF Existing
Utility
Details: # 5
Service
Provided
Install Fire
Hydrant
Quantity 1 Unit EA Existing
Utility
Details: # 6
Service
Provided
Remove
Existing Fire
Hydrant
Quantity 1 Unit EA
Existing
Utility
Details: # 7
Service
Provided
Remove Water
Main, 8-inch
Quantity 253 Unit
LF Existing
Utility
Details: # 8
Service
Provided
Install Water
Meter
Quantity 4
Unit EA Existing Service Install Water Quantity
Utility
Details: # 9
Provided Main, 8-inch
805 Unit LF Existing
Utility
Details: # 10
Service
Provided
Install Gate
Valve, 6-inch
Quantity 1 Unit EA Existing
Utility
Details: # 11
Service
Provided
Install Gate
Valve, 8-inch
Quantity 4 Unit EA Existing
Utility
Details: # 12
Service
Provided
Install Water
Service Line,
¾-inch
Quantity 70 Unit LF
Existing
Utility
Details: # 13
Service
Provided
Install Water
Service Line,
1-inch
Quantity 85 Unit
LF Existing
Utility
Details: # 14
Service
Provided
Remove
Existing
Water Meter
Box
Quantity 4
Unit EA Project Phase Construction Is Applicable Yes
Work Plan
Details: # 1
Work Plan
Description
STA 107+04,
17' LT
Dependent
Activities
NA Plan Stage
NA Average
Number of
Workers
5 Begin Day 1 Duration in
Calendar
Days:
1 Productive
Days/Week
5 Work Plan
Details: # 2
Work Plan
Description
STA 107+06,
10' LT
Dependent
Activities
NA Plan Stage NA Average
Number of
Workers
5
Begin Day 2 Duration in
Calendar
1 Productive
Days/Week
5
Days:
Work Plan
Details: # 3
Work Plan
Description
STA 107+00,
19' LT
Dependent
Activities
NA Plan Stage
NA Average
Number of
Workers
5 Begin Day 3 Duration in
Calendar
Days:
1 Productive
Days/Week
5 Work Plan
Details: # 4
Work Plan
Description
STA 107+97,
19'RT
Dependent
Activities
NA Plan Stage NA Average
Number of
Workers
5
Begin Day 4 Duration in
Calendar
Days:
3 Productive
Days/Week
5
Work Plan
Details: # 5
Work Plan
Description
STA 107+97,
19' RT
Dependent
Activities
STA 107+97,
19' RT
Install Water
Meter
Plan Stage
na Average
Number of
Workers
5 Begin Day 7 Duration in
Calendar
Days:
3 Productive
Days/Week
5 Work Plan
Details: # 6
Work Plan
Description
STA 107+01,
17' RT
Dependent
Activities
na Plan Stage na Average
Number of
Workers
5
Begin Day 10 Duration in
Calendar
Days:
2 Productive
Days/Week
5
Work Plan
Details: # 7
Work Plan
Description
STA 107+21,
9' LT
Dependent
Activities
na Plan Stage
na Average
Number of
Workers
5 Begin Day 12 Duration in
Calendar
Days:
3 Productive
Days/Week
5 Work Plan
Details: # 8
Work Plan
Description
STA 201+39,
31' RT
Dependent
Activities
na Plan Stage na Average
Number of
Workers
5
Begin Day 15 Duration in
Calendar
Days:
3 Productive
Days/Week
5
Work Plan
Details: # 9
Work Plan
Description
STA 210+26,
35' RT
Dependent
Activities
na Plan Stage
na Average
Number of
Workers
5 Begin Day 18 Duration in
Calendar
Days:
3 Productive
Days/Week
5 Work Plan
Details: # 10
Work Plan
Description
STA 210+26,
35' RT
Dependent
Activities
STA 210+26,
35' RT
Install Water
Meter
Plan Stage na Average
Number of
Workers
5
Begin Day 21 Duration in
Calendar
Days:
3 Productive
Days/Week
5
Work Plan
Details: # 11
Work Plan
Description
STA 108+89,
41' LT
Dependent
Activities
na Plan Stage
na Average
Number of
Workers
5 Begin Day 24 Duration in
Calendar
Days:
3 Productive
Days/Week
5 Work Plan
Details: # 12
Work Plan
Description
STA 108+89,
41' LT
Dependent
Activities
STA 108+89,
41' LT
Install Water
Meter
Plan Stage na Average
Number of
Workers
5
Begin Day 27 Duration in 3 Productive 5
Calendar
Days:
Days/Week
Work Plan
Details: # 13
Work Plan
Description
STA 109+35,
57' LT
Dependent
Activities
na Plan Stage
na Average
Number of
Workers
5 Begin Day 30 Duration in
Calendar
Days:
3 Productive
Days/Week
5 Work Plan
Details: # 14
Work Plan
Description
STA 109+356,
62' LT
Dependent
Activities
STA 109+35,
57' LT
Install Fire
Hydrant
Plan Stage na Average
Number of
Workers
5
Begin Day 33 Duration in
Calendar
Days:
3 Productive
Days/Week
5
Work Plan
Details: # 15
Work Plan
Description
STA 108+75,
13' LT
Dependent
Activities
na Plan Stage
na Average
Number of
Workers
5 Begin Day 36 Duration in
Calendar
Days:
2 Productive
Days/Week
5 Work Plan
Details: # 16
Work Plan
Description
STA 109+41,
44' RT
Dependent
Activities
na Plan Stage na Average
Number of
Workers
5
Begin Day 38 Duration in
Calendar
Days:
2 Productive
Days/Week
5
Work Plan
Details: # 17
Work Plan
Description
STA 109+06,
64' RT
Dependent
Activities
na Plan Stage
na Average
Number of
Workers
5 Begin Day 40 Duration in
Calendar
Days:
3 Productive
Days/Week
5 Work Plan
Details: # 18
Work Plan
Description
STA 109+06,
64' RT
Dependent
Activities
STA 109+06,
64' RT
Install Water
Meter
Plan Stage na Average
Number of
Workers
5
Begin Day 43 Duration in
Calendar
Days:
3 Productive
Days/Week
5
Work Plan
Details: # 19
Work Plan
Description
STA 111+06,
22' RT
Dependent
Activities
na Plan Stage
na Average
Number of
Workers
5 Begin Day 46 Duration in
Calendar
Days:
3 Productive
Days/Week
5 Work Plan
Details: # 20
Work Plan
Description
STA 200+02,
23' LT
Dependent
Activities
na Plan Stage na Average
Number of
Workers
5
Begin Day 48 Duration in
Calendar
Days:
3 Productive
Days/Week
5
DOT 8413 A
Sept 2005 DEPARTMENT OF TRANSPORTATION
State of Georgia
Atlanta,Georgia 30308
APPLICATION AND PERMIT FOR UTILITY FACILITY ENCROACHMENT
APPLICATION IS HEREBY MADE TO THE GEORGIA DEPARTMENT OF TRANSPORTATION BY:
CITY OF ATLANTA (UTILITY - NAME AND ADDRESS)
72 Marietta Street 5th Floor , Atlanta GA-30303
FOR PERMISSION TO CONSTRUCT OPERATE AND MAINTAIN THE FOLLOWING DESCRIBED UTILITY FACILITY WITHIN OR FROM THE RIGHT-OF-WAY
OFSTATE HIGHWAY NO. 040200 COUNTY ROAD NO. IN DeKalb COUNTY.
DESCRIPTION: Proposed water facilities relocation work includes the following: adjust one fire hydrant,
adjust one water meter box, abandon one water valve, adjust one water valve. install one water meter and
box, install one 6in gate valve, install four 8in valves, install one fire hydrant
LOCATION: Mile Point(0.62) TO Mile Point(1.03)
THE UTILITY SHALL COMPLY WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) CURRENT EDITION. IT IS ANTICIPATED
THAT THE TEMPORARY TRAFFIC CONTROL UTILIZED FOR THIS INSTALLATION WILL BE IN ACCORDANCE WITH ONE OF THE FOLLOWING:
[X] MUTCD 6-TYPICAL APPLICATION PLAN [ ] DETAILED TRAFFIC CONTROL PLAN
(ATTACHED)
[ ] COMBINATION TYPICAL APPLICATION &
DETAIL TRAFFIC CONTROL PLAN (ATTACHED)
THE UTILITY FACILITIES COVERED HEREBY SHALL BE INSTALLED IN ACCORDANCE WITH THE PLANS ATTACHED HERETO AND MADE A PART
HEREOF. UTILITY AGREES TO COMPLY WITH AND BE BOUND BY THE DEPARTMENTS UTILITY ACCOMMODATION POLICY AND STANDARDS,
CURRENT EDITION, ON FILE IN THE GENERAL OFFICE OF THE DEPARTMENT OF TRANSPORTATION, MADE A PART HEREOF BY REFERENCE, AND
ALL GENERAL PROVISIONS AND SPECIAL PROVISIONS SHOWN ON THE REVERSE HEREOF, OR ATTACHED HERETO, DURING THE INSTALLATION,
OPERATION AND MAINTENANCE OF SAID UTILITY FACILITIES WITHIN OR FROM THE RIGHT-OF-WAY.
PERMIT REQUESTED THIS 31 DAY OF August, 2021
100220
( MEMBER CODE )
LaTonya Moore
WITNESS TO SIGNATURE
LaTonya Moore
( SIGNATURE - Electronic )
Special Projects Coordinator 404-546-3256 (TITLE & PHONE NUMBER)
PERMISSION IS GRANTED FOR THE ABOVE DESCRIBED UTILITY FACILITY ENCROACHMENT IN ACCORDANCE WITH THE PLANS AND PROVISIONS
HEREOF.
THIS PERMIT IS TO BE STRICTLY CONSTRUED AND NO WORK OTHER THAN THAT SPECIFICALLY DESCRIBED ABOVE IS HEREBY AUTHORIZED.
PERMIT GRANTED THIS_________________DAY OF_______________20_____. DEPARTMENT OF TRANSPORTATION
BY:____________________________________________
(DISTRICT ENGINEER)
DISTRICT NO. 7 COUNTY DeKalb STATE ROUTE NO.040200 U.S._____________ CO. RD. NO.
PROJECT NO. 0013333 ACTIVE___________
UNDER CONSTR___________________
PERMIT NO. 1246826
Existing facility locations were identified using Subsurface investigation(SUE) dated: Mar 11, 2020
This schedule is based on Revision dated: Jul 23, 2021
If any changes are made to the plans after this date, which affect the utility, then this schedule may require modification.
Original schedule
Project: County: DeKalb Route/Road :040200
Description: I-20 EB @ CS 2776/MAYNARD TERRACE
A. SUMMARY OF UTILITY FACILITIES AND UTILITY ADJUSTMENT SCHEDULE.List of all existing facilities within project (exclude minor items)
Quantity, Type of facility, Type ofservice Quantity in conflict Units
Adjust Water Meter Box to Grade 1 EA
Adjust Water Valve Box to Grade 1 EA
Adjust Fire Hydrant to Grade 1 EA
Install Water Main, 6-inch 26 LF
Install Fire Hydrant 1 EA
Remove Existing Fire Hydrant 1 EA
Remove Water Main, 8-inch 253 LF
Install Water Meter 4 EA
Install Water Main, 8-inch 805 LF
Install Gate Valve, 6-inch 1 EA
Install Gate Valve, 8-inch 4 EA
Install Water Service Line, þ-inch 70 LF
Install Water Service Line, 1-inch 85 LF
Remove Existing Water Meter Box 4 EA
Prepared by Title Phone Date
LaTonya MooreSpecial ProjectsCoordinator 404-546-3256 Aug 31, 2021
Approved by GDOT Title Phone Date
Comments
B. SPECIAL REQUIREMENTS (staging required, dependent activities, joint-use coordination,etc.).The work noted in this schedule will be performed by GDOT Contractor, schedule for roadway and pedestrianimprovements. GDOTs Contractor to provide at least four-week advance notice of work in areas identified for COArelocations.
GDOT - UTILITY ADJUSTMENT SCHEDULE - Page 1 of 3
Utility: CITY OF ATLANTA P.I. No: 0013333 Permit #: 1246826 Date: Aug 31, 2021
C. WORK PLAN - provide disposition of all existing and proposed facilities on project.
LocationDescription of
utility workDependentactivities Plan Stage No. Days
Averagenumber ofworkers
Construction
STA 107+04,17' LT
Adjust WaterValve Box to
Finished Grade NA NA 1 5
STA 107+06,10' LT
Adjust WaterValve Box to
Finished Grade NA NA 1 5
STA 107+00,19' LT
Adjust WaterMeter Box to
Finished Grade NA NA 1 5
STA 107+97,19'RT
Install WaterMeter NA NA 3 5
STA 107+97,19' RT
Install 27 LF of3/4" Water
Service Line
STA 107+97,19' RT InstallWater Meter na 3 5
STA 107+01,17' RT
RemoveExisting Water
Meter na na 2 5
STA 107+21, 9'LT
Install 8"GateValve na na 3 5
STA 201+39,31' RT
RemoveExisting Water
Meter na na 3 5
STA 210+26,35' RT
Install WaterMeter na na 3 5
STA 210+26,35' RT
Install 43 LF of3/4" Water
Service Line
STA 210+26,35' RT InstallWater Meter na 3 5
STA 108+89,41' LT
Install WaterMeter na na 3 5
STA 108+89,41' LT
Install 75 LF of1" Water
Service Line
STA 108+89,41' LT InstallWater Meter na 3 5
STA 109+35,57' LT
Install FireHydrant withThrust Block na na 3 5
STA 109+356,62' LT
Install 6" GateValve
STA 109+35,57' LT InstallFire Hydrant na 3 5
STA 108+75,13' LT
RemoveExisting Water
Meter na na 2 5
STA 109+41,44' RT
RemoveExisting Water
Meter na na 2 5
STA 109+06,64' RT
Install WaterMeter na na 3 5
STA 109+06,64' RT
Install 10 LF of1" Water
Service Line
STA 109+06,64' RT InstallWater Meter na 3 5
STA 111+06,22' RT
Install 8" GateValve na na 3 5
STA 200+02,23' LT
Install 8" GateValve na na 3 5
GDOT - UTILITY ADJUSTMENT SCHEDULE - Page 2 of 3
Utility: CITY OF ATLANTA P.I. No: 0013333 Permit #: 1246826 Date: Aug 31, 2021
D. SCHEDULE SUMMARY FOR WORK PLAN.Exclude weekends, weather delays and non-productive time:
Project duration for non-concurrent activities in days: 51
Work Phase Total estimated days Prior to project award After project award
Construction 51 51
GDOT - UTILITY ADJUSTMENT SCHEDULE - Page 3 of 3
Utility: CITY OF ATLANTA P.I. No: 0013333 Permit #: 1246826 Date: Aug 31, 2021
PROJECT LOCATION
THE DEPARTMENT OF TRANSPORTATION.
STATE HIGHWAY DEPARTMENT OF GEORGIA, AND SHALL BE DEEMED TO MEAN
DEPARTMENT ", OR " DEPARTMENT " WHEN THE CONTEXT THEREOF MEANS THE
HIGHWAY DEPARTMENT ", GEORGIA STATE HIGHWAY DEPARTMENT ", " HIGHWAY
WITH THIS DOCUMENT, TO " STATE HIGHWAY DEPARTMENT OF GEORGIA ", "STATE
DOCUMENTS, DRAWINGS, OR PHOTOGRAPHS USED, OR TO BE USED IN CONNECTION
ALL REFERENCES IN THIS DOCUMENT, WHICH INCLUDES ALL PAPERS, WRITINGS,
NOTE :
OF 1988.
AMERICAN VERTICAL DATUM (NAVD)
1983)/94 WEST ZONE, AND THE NORTH
COORDINATE SYSTEM OF 1984 (NAD
USING THE HORIZONTAL GEORGIA
THIS PROJECT HAS BEEN PREPARED
44-0001
PLANS COMPLETED
DEPARTMENT OF TRANSPORTATIONSTATE OF GEORGIA
REVISIONS
FEDERAL ROUTE #
STATE ROUTE #
P.I. NO.
LOCATION SKETCH
SUBSECTIONS 102.04, 102.05, AND 104.03 OF THE SPECIFICATIONS.
OF TRANSPORTATION IN ANY WAY. THE ATTENTION OF BIDDER IS SPECIFICALLY DIRECTED TO
SAME ARE SHOWN AS INFORMATION ONLY, ARE NOT GUARANTEED, AND DO NOT BIND THE DEPARTMENT
FIELD INVESTIGATIONS AND ARE BELIEVED TO BE INDICATIVE OF ACTUAL CONDITIONS. HOWEVER, THE
INDICATED THEREBY, WHETHER BY DRAWINGS OR NOTES, OR IN ANY OTHER MANNER, ARE BASED UPON
THE DATA, TOGETHER WITH ALL OTHER INFORMATION SHOWN ON THESE PLANS OR IN ANYWAY
UTILITY RELOCATION PLANS
US 29
SR 14
FEDERAL AID PROJECT
DRAWING INDEX
COVER
GENERAL NOTES
LEGEND
UTILITY RELOCATION PLANS
CONSTRUCTION DETAILS
44-0002 to 44-0003
DESCRIPTION
44-0005 to 44-0008
44-0009 to 44-0010
SUMMARY OF QUANTITIES SHEET06-XXXX
44-0004
44-0001
DRAWING NO.
PARSONS BRINCKERHOFF - BENCHMARK
DESIGN
PROPOSED ROUNDABOUT
I-20 EAST BOUND AT MAYNARD TERRACE
0013333
B
B
B
B
TS
A T E
O
GF
EO
R
GI
A
17
76
CONS
TIT
UTI
ON
JU
STI
C
E
OM
DER
ATIO
N
DOMWIS
FAX: 404-237-3015
TEL: 404-237-2115
ATLANTA, GA 30326
SUITE 2400, TOWER PLACE 100
3340 PEACHTREE RD NE
WSP USA Inc.
12/17/2020
USER:USCW670696
GPLOT-V8
gplotborder-V8i-PO-COA.tbl
C:\Users\uscw670696\Desktop\CAD\0013333\700 CAD\740 Sheets\0013333_44-0001.dgn
GRWCOV
CONCOV
07/31/2015
DRAWING No.
0013333
117
+00
116
+00
10
5+0
0
10
6+0
0
10
7+00
108
+00
109
+00
110
+00
111
+00
112
+00
113
+00
114
+00
115
+00
RA
MP
I-20 EB M
cP
HERS
ON
AVE
TERRACE
MAYNARD
MAYNARD TERRACE
E 2245457.793N 1361599.109STA 106+83.00MAYNARD TERRACE CLBEGIN PROJECT
E 2245727.053
N 1362402.373
STA 115+57.00
MAYNARD TERRACE CL
END PROJECT
200+00300+00
300 600
SCALE IN FEET
0 150
Project No.
PL
PL
PL
PLPL
PL
PL
PL
PL
P L P L
P L P L
P L
PL
PL
PL
PL
P L
P L
P L
P L
P L
P L P L
TO ASSURE WATER TIGHTNESS PRIOR TO BACKFILLING.
CONSTRUCTED OF MATERIALS AND WITH JOINTS THAT ARE EQUIVALENT TO WATER MAIN STANDARDS OF CONSTRUCTION AND SHALL BE PRESSURE TESTED
WHEN LOCAL CONDITIONS PREVENT A VERTICAL SEPARA110N OF 18-INCHES, THE SEWER PASSING OVER OR UNDER THE WATER MAIN SHALL BE 19.
WATER-TIGHTNESS PRIOR TO BACKFILLING.
OF MATERIALS AND WITH JOINTS THAT ARE EQUIVALENT TO WATER MAIN STANDARDS OF CONSTRUCTION AND BE PRESSURED TESTED TO ASSURE
ELEVATION THAT THE BOTTOM OF THE WATER MAIN IS AT LEAST 18-1NCHES ABOVE THE TOP OF THE SEWER, PROVIDED THE SEWER BE CONSTRUCTED
PROVIDED THE SEWER IS LAID IN A SEPARATE TRENCH OR AN UNDISTURBED EARTH SHELF LOCATED ON ONE SIDE OF THE WATER MAIN AT SUCH AN
WHEN LOCAL CONDITIONS PREVENT A HORIZONTAL SEPARATION OF 10 FEET, THE SEWER PIPE MAY BE LAID CLOSER AT THE DISCRETION OF THE DWM, 18.
THEIR LATERAL SEPARATION IS LESS THAN 10 FEET. THE DISTANCE SHALL BE MEASURED EDGE-TO-EDGE.
A PARALLEL BURIED WATER MAIN IF AS IN NO INSTANCE SHALL A PROPOSED BURIED SEWER BE INSTALLED AT THE SAME OR HIGHER ELEVATION 17.
THE MINIMUM DEPTH OF COVER REQUIREMENTS.
ALIGNMENT OF THE PROPOSED WATER MAINS SHALL BE ADJUSTED TO ALLOW A MIN. CLEARANCE OF 18-INCHES. SUCH ADJUSTMENT SHALL CONFORM TO
WHERE PROPOSED WATER MAINS SHOWN ON PLANS ARE REQUIRED TO CLEAR EXISTING UTILITIES, WHETHER SHOWN OR NOT ON PLANS, THE VERTICAL 16.
OBTAINING THE NECESSARY HYDRANT METER PERMIT AND HYDRANT KEY FROM THE DWM METER APPLICATION OFFICE (404-330-8091).
WATER MAINS OR OTHER EXISTING SERVICES UNLESS OTHERWISE AUTHORIZED BY THE DWM INSPECTORS. CONTRACTORS MAY OPERATE HYDRANTS AFTER
THE CONTRACTOR SHALL NOT OPERATE OR WORK ON ANY VALVES, WATER METERS, OR HYDRANTS, OR MAKE ANY CONNECTIONS ON OR TO, EXISTING 15.
TEMPORARY SERVICE CONNECTIONS WILL BE MADE UNDER THE SUPERVISION OF THE DWM INSPECTORS.
CONTINUOUS SERVICE TO ALL EXISTING METERS AND FIRE SERVICES SHALL BE MAINTAINED EXCEPT AS AUTHORIZED BY THE DWM. THE REQUIRED 14.
ALL SUCH MATERIAL ARE NOT SALVAGEABLE BY ANY CONTRACTOR.
ALL METERS, FIRE HYDRANTS, VALVES, AND PIPES WITHIN THE CITY OF ATLANTA WATER SYSTEM ARE THE SOLE PROPERTY OF THE CITY OF ATLANTA. 13.
GRAVEL SHALL BE MINIMUM OF 8-INCH ABOVE THE WEEP HOLES AND SHALL EXTEND TO A POINT 18-INCHES BELOW THE WEEP HOLES.
TO ALLOW THE FIRE HYDRANT "WEEP HOLES" TO FUNCTION PROPERLY, THE SHOE OF THE FIRE-HYDRANT SHALL BE SURROUNDED BY GRAVEL. THE 12.
DIRECTED BY THE DWM.AS BLOCK AND IT SHALL BE TIED TO THE PIPE WITH SUITABLE METAL TIE-RODS OR CLAMPS
THE SHOE OF EACH HYDRANT SHALL BE WELL BRACED AGAINST UNDISTURBED EARTH AT THE END OF THE TRENCH WITH A POURED CONCRETE BRACE 11.
LOCATED AT THE TEE UNLESS OTHERWISE SPECIFIED OR APPROVED BY THE DWM ENGINEER.
ALL FIRE HYDRANTS SHALL BE INSTALLED OR RELOCATED WITH A 6-INCH DIAMETER BRANCH LINE AND SHALL HAVE A 6-INCH GATE VALVE 10.
500 FEET FOR RESIDENTIAL AREAS. CONTRACTOR SHALL FIELD VERIFY FINAL DEPTH OF BURY BASED UPON PROPOSED WATER MAIN INSTALLATION.
ALL FIRE-HYDRANTS SHALL BE A MAXIMUM DISTANCE OF 300 FEET FOR AREAS ZONED AS COMMERCIAL CENTRAL BUSINESS DISTRICT AREAS, AND 9.
ENGINEER. ALL CONSTRUCTION SHALL BE IN CONFORMITY WITH THE MINIMUM STANDARDS AND SPECIFICATIONS OF THE CITY OF ATLANTA.
IMMEDIATELY. ANY REVISED WATER CONSTRUCTION BASED ON FIELD CONDITIONS DIFFERING FROM THE PLANS SHALL BE APPROVED BY THE CITY
CONSTRUCTION. ANY VARIANCES OR UNFORESEEN CONFLICTS WITH ANY PROPOSED CONSTRUCTlON SHALL BE COMMUNICATED TO THE CITY ENGINEER
WATER MAINS, SERVICE LINES, AND APPURTENANCES. CONTRACTOR SHALL FIELD VERIFY THE SIZE AND DEPTH OF WATER FACIL1T1ES PRIOR TO
THE WATER FACILITIES ILLUSTRATED ON THESE PLANS ARE FOR INFORMATIONAL PURPOSES ONLY, AND SHOW APPROXIMATE LOCATIONS OF VARIOUS 8.
BE NOTIFIED OF INTENT TO PRESSURE TEST PRIOR TO SCHEDULED TESTING.
ALL LINES 8" OR GREATER MUST BE PRESSURE TESTED AT 250 PSI FOR A MINIMUM OF TWO (2) HOURS. CITY OF ATLANTA INSPECTOR MUST 7.
ANY CHANGES TO THE APPROVED WATER DRAWINGS MUST BE APPROVED BY DWM WATER DEPARTMENT ENGINEER.6.
BE OUTSIDE OF CURVE RADIUS.
FIRE-HYDRANTS SHOWN IN THE RADIUS OF A CURVE SHALL BE FIELD ADJUSTED SO THAT THE ACTUAL INSTALLATION OF FIRE HYDRANTS WILL 5.
CONCRETE THRUST BLOCKING SHALL BE INSTALLED AT ALL BENDS, TEES, HYDRANTS, PLUGS, ETC. PER DETAIL4.
MUST BE NOTIFIED 48 HOURS PRIOR TO START OF EACH CONSTRUCTlON ACTIVITY AND ANY CHANGES IN THE ADVANCE SCHEDULE.
A 2-WEEK ADVANCED SCHEDULE TO THE INSPECTOR INDICATING THE PROPOSED WORK AND AREAS OF CONSTRUCTION. THE DWM WATER INSPECTOR
THESE ITEMS SHALL BE NECESSARY PRIOR TO THE ASSIGNMENT OF A CITY OF ATLANTA INSPECTOR. THE CONTRACTOR SHALL PROVIDE
EXECUTED HOLD HARMLESS AGREEMENT
COMPLETED CITY OF ATLANTA QUALIFIED CONTRACTOR EXPERIENCE FORM
MANUFACTURER CUT SHEETS FOR ALL MATERIALS TO BE USED
GEORGIA UTILITY LICENSE CERTIFICATION
ENGINEER PRIOR TO CONSTRUCTION THE FOLLOWING ITEMS:
THE CONTRACTOR PERFORMING THE WATER CONSTRUCTION SHALL REQUEST A PRE-CONSTRUCTION CONFERENCE AND SUBMIT TO THE CITY 3.
MADE OF DUCTlLE IRON, AND COMPLY WITH THE CITY OF ATLANTA STANDARDS AND SPECIFICATIONS.
ALL CONSTRUCTION METHODS AND MATERIALS USED TO EXTEND, RELOCATE, OR ABANDON CITY OF ATLANTA WATER SYSTEM MUST BE 2.
WATERSHED MANAGEMENT (DWM) ENGINEERS OR INSPECTORS.
ALL REFERENCES TO ENGINEER OR INSPECTOR WITHIN THESE WATER GENERAL NOTES SHALL REFER TO CITY OF ATLANTA DEPARTMENT OF1.
CITY OF ATLANTA WATER GENERAL NOTES:
MATERIAL BE DROPPED OR DUMPED INTO THE TRENCH.
AS TO PREVENT DAMAGE TO WATER MAIN MATERIALS AND PROTECTIVE COATINGS AND LININGS. UNDER NO CIRCUMSTANCES SHALL WATER MAIN
LOWERED INTO THE TRENCH, PIECE BY PIECE, BY MEANS OF A DERRICK, ROPE, OR OTHER SUITABLE TOOLS OR EQUIPMENT, IN SUCH A MANNER
CONTRACTOR) FOR THE SAFE AND CONVENIENT EXECUTION OF THE WORK. ALL PIPE, FITTINGS, VALVES, AND FIRE HYDRANTS SHALL BE CAREFULLY
PROPER IMPLEMENTS, TOOLS, AND FACILITIES SATISFACTORY TO THE INSPECTOR SHALL BE PROVIDED AND USED BY APPLICANT (DEVELOPER OR 35,
VEHICULAR AND PEDESTRIAN SAFETY AND INGRESS AND EGRESS.
TO PREVENT MOVEMENT, INTERFERENCE AND/OR DANGER TO AS THEM FROM DAMAGE. ALL STORED PIPE SHALL BE SECURED IN SUCH A MANNER
AND FOREIGN MATTER AT ALL TIMES. PIPE, VALVES, AND FIRE HYDRANTS SHALL BE DRAINED AND STORED IN A MANNER THAT WILL PROTECT
INCORPORATED IN THE COMPLETED PROJECT. THE INTERIOR OF ALL PIPE, FITTINGS,AND OTHER APPURTENANCES SHALL BE KEPT FREE FROM DIRT
SAFE STORAGE: THE APPLICANT (DEVELOPER OR CONTRACTOR) SHALL BE RESPONSIBLE FOR THE SAFE STORAGE OF MATERIAL UNTIL IT HAS BEEN 34.
(DEVELOPER OR CONTRACTOR) SHALL EXERCISE CARE IN THE USE OF THE WATER. THE POINT OF USE. THE APPLICANT
DEPARTMENT. THE APPLICANT (DEVELOPER OR CONTRACTOR) SHALL FURNISH ALL NECESSARY PIPE OR HOSE EXTENSIONS AND TRANSPORTATION TO
AVAILABLE TO THE REQUESTING APPLICANT (DEVELOPER OR CONTRACTOR) AT HIS EXPENSE AND AT THE NEAREST EXISTING FACILITIES OF THE
CONTRACTOR) SHALL OBTAIN THROUGH THE DWM'S APPLICATIONS OFFICE. WATER USED FOR TESTING MAINS AND WASHING STREETS WILL BE MADE
WATER USED FOR ALL PURPOSES WILL BE SUPPLIED THROUGH A METERED CONNECTION WHICH THE APPLICANT (DEVELOPER OR 33.
SPECIFICALLY APPROVED BY THE DWM ENGINEER.
THE MINIMUM DEPTH OF COVER SHALL BE FOUR (4) FEET AND THE MAXIMUM COVER SHALL BE FIVE (5) FEET. ANY DEVIATIONS MUST BE 32.
DWM ENGINEER SHALL BE FINAL AND CONCLUSIVE AND BINDING UPON ALL PARTIES TO THE WORK.
POINT CONCERNING THE CHARACTER, ACCEPTABILITY AND NATURE OF THE SEVERAL KINDS OF WORK AND CONSTRUCTION THEREOF, THE DECISION OF THE
TO THE CLASSIFICATIONS, OR AS TO THE MEANING OF THE PLANS OR SPECIFICATIONS ON ANY AS SHOULD ANY DISAGREEMENT OR DIFFERENCE ARISE 31.
THE INTENT OF THE JOB PLANS AND SPECIFICATIONS
INSPECTOR WITH EVERY REASONABLE FACILITY TO DETERMINE WHETHER OR NOT THE WORK PERFORMED IS IN ACCORDANCE WITH THE REQUIREMENTS AND
ITS OWN EXPENSE UPON BEING NOTIFIED OF SUCH DEFECTS BY THE INSPECTOR. THE REQUESTING AGENCY OR CONTRACTOR SHALL FURNISH THE
CONSIDERED AS A WAIVER OF ANY DEFECTS WHICH MAY BE DISCOVERED LATER AND THE REQUESTING AGENCY SHALL MAKE NECESSARY REPAIRS AT
FULFILL THE CONTRACT IN A SATISFACTORY MANNER. THE FAILURE OF THE INSPECTOR TO DISCOVER IMPROPER WORKMANSHIP SHALL NOT BE
THE INSPECTION OF THE WORK SHALL NOT RELIEVE THE DEVELOPER OR CONTRACTOR OF ANY OF THEIR RESPONSIBILITIES AND OBLIGATIONS TO 30.
THE STANDARDS ARE MET.AS TIME
BY THE DWM ENGINEER. FAILURE OF A PROJECT TO MEET THE DEPARTMENT'S STANDARDS WILL RESULT IN ACCEPTANCE BEING WITHHELD UNTIL SUCH
SUSPEND OR REQUEST THE DEVELOPER AND CONTRACTOR TO SUSPEND THE WORK UNTIL ANY QUESTIONS CAN BE REFERRED TO AND A DECISION RENDERED
AGENCY'S ENGINEER OF ANY FAILURE OF THE WORK TO CONFORM TO THE DEPARTMENTS CURRENT REQUIREMENTS AND STANDARDS. THE INSPECTOR MAY
THE DWM WILL PROVIDE INSPECTORS WHO WILL BE AUTHORIZED TO OBSERVE AND/OR INSPECT ALL WORK DONE AND WHO SHALL INFORM THE REQUESTING 29.
WORK.
PROGRESS OF THE WORK AND THE CONVENIENCE, COMFORT, AND SAFETY OF THE PUBLIC AND PROPERTY OWNERS OR TENANTS IN THE VICINITY OF THE
THE LENGTH OF TRENCH TO BE OPENED IN ADVANCE OF THE COMPLETED WORK SHALL BE LIMITED BY THE ENGINEER WITH REGARD TO BOTH THE RAPID 28.
AND SHALL NOT ROCK. THE TOP OF THE LID SHALL BE FLUSH WITH THE TOP OF THE BOX, AND BANDED FOR SHIPMENT.
PLUS OR MINUS 1/32". WHEN COATING IS COMPLETE, THE LID SHALL FIT SNUGLY IN ITS RECEPTACLES IN THE TOP OF THE BOX WITHOUT FORCING
ALL OF THE VALVE BOXES TO BE THE ATLANTA WATER DEPARTMENT PATTERN. TOP SECTION TO BE CAST WITH A SHELL CORE AND A TOLERANCE OF 27.
48-INCH-405 TURNS
12-INCH-38 TURNS, 24-INCH-230 TURNS, 42-INCH-350 TURNS
8-INCH-27 TURNS, 20-INCH-133 TURNS, 36-INCH-450 TURNS
6-INCH-21 TURNS, 16-INCH-102 TURNS, 30-1NCH-350 TURNS
MINUS FIVE FOR 16&-INCH AND LARGER VALVES:
SHOWN BELOW PLUS OR MINUS THREE FOR 6-INCH THROUGH 12-INCH VALVES, AND PLUS ORAS THE NUMBER OF TURNS TO OPEN SHALL BE 26.
APPROVAL PRIOR TO THE START OF ANY WATER MAIN WORK.
MAIN INSTALLATION CONTRACTOR EXPERIENCE QUALIFICATION FORM AND THEIR STATE OF GEORGIA UTILITY LICENSE CERTIFICATION TO THE DWM FOR
INSTALLER OF WATER MAINS OR WATER FACILITIES.THE CONTRACTOR OR HIS AUTHORIZED SUB-CONTRACTOR MUST SUBMIT THE COMPLETED FORM WATER
AN AS TO PERMIT THE DWM TO EVALUATE THEIR ACCEPTABILITY AS PREVIOUS EXPERIENCE OR EXPERIENCE OF THEIR AUTHORIZED SUB-CONTRACTOR
AN INSTALLER OF ANY WATER FACILITIES MUST PROVIDE SUFFICIENTLY DETAILED INFORMATION OF THEIR AS ANY CONTRACTOR WHO IS PROPOSED 25.
ALL TAPS SHALL REMAIN EXPOSED AT THE MAIN UNTIL THE SYSTEM HAS BEEN SUCCESSFULLY INSPECTED, DISINFECTED AND TESTED FOR PRESSURE.24.
UTILITIES EXCEPT SANITARY SEWER LINES WHERE FEASIBLE.
WATER MAINS, VALVES, HYDRANTS AND APPURTENANCES SHALL BE INSTALLED BEFORE INSTALLATION OF THE SUB-BASE COURSE OF PAVING OR ANY OTHER 23.
PAPER COPY.AS WELL AS FOLLOWING RECEIPT OF ACCEPTABLE "AS-BUILT" PLANS IN ELECTRONIC FORMAT
COA DWM PERSONNEL WILL BE MADE. THE ACCEPTANCE OF THE WATER WILL BE CONFIRMED BY A LETTER OF ACCEPTANCE WHICH WILL BE ISSUED
UPON COMPLETION OF THE SUCCESSFUL HYDROSTATIC TEST, AND THE LABORATORY ACCEPTANCE OF THE WATER QUALITY TEST A FINAL INSPECTION BY22.
INSPECTOR AND THAT THE NEW OR REARRANGED WATER MAIN PASSES THE DWM'S STANDARD QUALITY AND BACTERIOLOGICAL TESTS.
ACCEPTANCE OF THE NEW OR REARRANGED WATER MAIN IS CONDITIONAL UPON A SUCCESSFUL HYDROSTATIC TEST UNDER THE SUPERVISION OF A DWM 21.
THE WATER MAIN. THE SEWER SHALL BE CONSTRUCTED OF DIP AND SUBJECTED TO HYDROSTATIC TESTS.
THE LENGTH OF PROPOSED PIPE BE CENTERED AT THE POINT OF CROSSING SO THAT THE JOINTS WILL BE EQUIDISTANT AND AS FAR AS POSSIBLE FROM
TO PREVENT EXCESSIVE DEFECTION OF JOINTS AND SETTING ON AND BREAKING THE WATER MAIN. THE SEWER SHALL BE LAID IN SUCH A MANNER THAT
BOTTOM OF THE SEWER AND TOP OF THE WATER MAIN AS WELL AS ENCASEMENT OF THE SEWER IN CONCRETE TO PROVIDE ADEQUATE STRUCTURAL SUPPORT
WHEN WATER MAINS CROSS UNDER SEWERS, ADDITIONAL MEASURES SHALL BE TAKEN BY PROVIDING A VERTICAL SEPARATION OF 18-INCHES BETWEEN THE 20.
GENERAL NOTES
44-0002
I-20 EB @ CS 2776/MAYNARD TERRACE
REVISION DATES
12/17/2020
USER:USCW670696
GPLOT-V8
gplotborder-V8i-PO-COA.tbl
C:\Users\uscw670696\Desktop\CAD\0013333\700 CAD\740 Sheets\0013333_44-0002.dgn
10:57:53 PM
GPLN10/23/2015
CHECKED:
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
DRAWING No.
Project No.
0013333
BY THE AGENCY OR CONTRACTOR AFTER INSTALLATION WITH A COMPATIBLE PROTECTIVE MATERIAL.
53. ALL STRAPS AND RODS SHALL BE COATED PRIOR TO INSTALLATION WITH AN APPROVED PROTECTIVE COATING. THE NUTS AND THREADS SHALL BE COATED
BE DIRECTED BY THE INSPECTOR. VALVE BOX LIDS SHALL BE SET AT FINISHED GRADE PRIOR TO POURING CONCRETE.
OVER THE OPERATING NUT OF THE VALVE WITH THE BOX COVER FLUSH WITH THE SURFACE OF THE FINISHED PAVEMENT OR SUCH OTHER LEVEL AS MAY
NO GEARING OR OPERATING MECHANISM. THE VALVE BOX SHALL NOT TRANSMIT SHOCK OR STRESS TO THE VALVE AND SHALL BE CENTERED AND PLUMB
52. A CAST IRON VALVE BOX OR MASONRY VAULT SHALL BE PROVIDED FOR EVERY VALVE. A VALVE BOX SHALL BE PROVIDED FOR EVERY VALVE WHICH HAS
AND A NEW CAN OF JOINT LUBRICANT PROVIDED.
SUBSTANCES, SHOULD DIRT OR OTHER FOREIGN SUBSTANCES CONTAMINATE THE LUBRICANT, THEN THE CONTAMINATED LUBRICANT SHALL BE THROWN AWAY
CARE MUST BE TAKEN. IN THE USE AND STORAGE OF THE JOINT LUBRICANT. THE LUBRICANT MUST BE KEPT FREE FROM DIRT AND OTHER FOREIGN
ENTRY OF SPIGOT INTO SOCKET. CLOSURE OF FLEXIBLE JOINT PIPE SHALL BE MADE ONLY THROUGH THE USE OF MECHANICAL JOINT SLEEVES.
WILL PROTECT THE GASKET FROM DAMAGE, PERMIT THE PROPER CENTERING OF PIPE IN GASKET, PROVIDE UNIFORM COMPRESSION OF GASKET, AND EASY
TOOL. THE SPIGOT ENDS OF CUT PIPE SHALL BE DRESSED AND TAPERED WITH A COARSE FILE OR APPROVED BEVELING DEVICE IN A MANNER THAT
ENTRY OF THE PIPE INTO THE SOCKET. THE SPIGOT END OF THE PIPE SHALL BE PUSHED "HOME" BY THE USE OF A RATCHET TYPE ASSEMBLY
(FURNISHED BY THE PIPE MANUFACTURER) SHALL BE APPLIED TO THE INSIDE OF THE GASKET AND SPIGOT END OF THE PIPE TO PERMIT EASY
THE GASKET SHALL BE CAREFULLY PLACED INTO THE SOCKET RECESS BY HAND, AND EVENLY SEATED. A THIN FILM OF SPECIAL LUBRICANT
THOROUGHLY CLEANED BY WASHING WITH SOAP AND WATER AND WIPED CLEAN AND DRY BEFORE THE GASKET IS INSERTED INTO THE SOCKET RECESS.
51. JOINTING OF FLEXIBLE ("PUSH-ON") JOINT PIPE SHALL BE MADE BY EXPERIENCED MECHANICS. SOCKETS, SPIGOTS, AND GASKETS SHALL BE
COMPLETED.
SHALL BE KEPT CLEAN AND SOCKETS, SPIGOTS, AND GASKETS SHALL BE KEPT CLEAN AND WET WITH CLEAN SOAPY WATER UNTIL EACH JOINT HAS BEEN
TIGHTENED SHALL BE THE BOTTOM BOLT, SECOND SHALL BE THE TOP BOLT, AND SO ON UNTIL ALL BOLTS ARE PULLED UP. THE GLANDS AND BOLTS
TIGHTNESS USING A TORQUE WRENCH SET TO THE MANUFACTURER'S SPECIFICATIONS. BOLTS SHALL BE TIGHTENED ALTERNATELY; FIRST BOLT
50. THE GLAND SHALL BE PUSHED INTO POSIT10N FOR COMPRESSING THE GASKET, ALL BOLTS AND NUTS SHALL BE TIGHTENED TO A UNIFORM PERMANENT
BRUSHED WITH CLEAN SOAPY WATER AND SHALL BE PUSHED INTO POSITION MAKING SURE THAT THE GASKET IS EVENLY SEATED IN THE SOCKET.
BEFORE SLIPPING THE GLAND AND GASKET OVER SPIGOT. THE SPIGOT SHALL BE INSERTED IN THE SOCKET TO FULL DEPTH. THE GASKET SHALL BE
49. JOINTS FOR MECHANICAL JOINT PIPE SHALL BE MADE BY EXPERIENCED MECHANICS. SOCKETS AND SPIGOTS SHALL BE WASHED WITH CLEAN SOAPY WATER
48. THE FLAME CUTTING OF PIPE BY ANY MEANS WILL NOT BE ALLOWED.
47. ALL 16-INCH AND LARGER DIAMETER PIPE SHALL BE CUT WITH A POWER-DRIVEN CUTTER OR OTHER APPROVED EQUIPMENT.
46. A WHEEL TYPE CUTTER OR POWER-DRIVEN SAW OR OTHER APPROVED EQUIPMENT SHALL BE USED FOR CUTTING 6-INCH, 8-INCH, AND 12-INCH INVOLVED.
SPIGOT SHALL BE BEVELED A MINIMUM OF 1/4-INCH WHEN "SLIP" JOINT CONNECTIONS ARE INVOLVED.
DAMAGE TO END PIPE OR LINING AND SO AS TO LEAVE A SMOOTH END AT RIGHT ANGLES TO THE AXIS OF THE PIPE. THE EDGE OF THE CUT
45. THE CUTTING OF PIPE FOR INSERTING VALVES, FITTINGS, OR CLOSURE PIECES SHALL BE DONE IN A NEAT AND WORKMAN LIKE MANNER WITHOUT
INSIDE DIAMETER OF THE PIPE. THE BRUSH SHALL AT ALL TIMES BE SUSPENDED OFF THE GROUND WHEN NOT IN USE.
OF EACH LENGTH OF PIPE SHALL BE BRUSHED CLEAN AS REQUIRED BY THE USE OF A CIRCULAR FIBER BRUSH HAVING A DIAMETER EQUAL TO THE
WIRE BRUSHED AND WIPED CLEAN AND DRY AND FREE FROM OIL AND GREASE OR OTHER FOREIGN MATERIAL BEFORE THE PIPE IS LAID. THE INTERIOR
44. ALL LUMPS, BLISTERS AND EXCESS COAL TAR COATING SHALL BE REMOVED FROM THE BELL AND SPIGOT, AND THE INSIDE OF THE BELLS SHALL BE
THAT THE NEWLY INSTALLED PIPE LENGTHS DO NOT "SLIDE" AND CAUSE A SEPARATION IN THE PREVIOUSLY MADE-UP JOINTS.
IS BEING LAID DOWN A HILL IN WHICH CASE, THE JOINTS ARE TO BE REVERSED SO THAT THE BELLS POINT UP THE HILL. CARE MUST BE TAKEN
43. IT IS THE NORMAL PROCEDURE TO LAY THE PIPE WITH THE BELLS FACING IN THE DIRECTION IN WHICH THE WORK IS PROGRESSING, UNLESS THE MAIN
AS WELL AS OVERNIGHT. IF WATER IS IN THE TRENCH, THE SEAL SHALL REMAIN IN PLACE UNTIL THE TRENCH HAS BEEN PUMPED COMPLETELY DRY.
APPROVED BY THE INSPECTOR. THE CONTRACTOR SHALL HAVE PLUGS AVAILABLE AT ALL TIMES. THIS PROVISION SHALL APPLY DURING THE NOON HOUR
42. AT TIMES WHEN PIPE LAYING IS NOT IN PROGRESS, THE OPEN ENDS OF THE PIPE SHALL BE CLOSED BY A WATERTIGHT PLUG OR OTHER MEANS
OF PROPER DIMENSIONS TO INSURE SUCH UNIFORM SPACE. PRECAUTIONS SHALL BE TAKEN TO PREVENT EARTH FROM ENTERING THE JOINT SPACE.
41. PIPE AND FITTINGS WHICH DO NOT ALLOW A SUFFICIENT AND UNIFORM SPACE FOR JOINTS SHALL BE REMOVED AND REPLACED WITH PIPE AND FITTINGS
THE BELLS.
TO THE CORRECT LINE AND GRADE. THE PIPE SHALL BE SECURED IN PLACE WITH APPROVED BACKFILL MATERIAL AND TAMPED AROUND IT EXCEPT AT
40. AFTER PLACING A LENGTH OF PIPE IN THE TRENCH, THE SPIGOT END SHALL BE CENTERED IN THE BELL AND THE PIPE FORCED HOME AND BROUGHT
OTHER MATERIAL SHALL BE PLACED IN THE PIPE.
LEFT THERE UNTIL THE CONNECTION IS TO BE MADE TO THE ADJACENT PIPE. DURING LAYING OPERATIONS, NO DEBRIS, TOOLS, CLOTHING OR
THAT BEFORE LOWERING THE PIPE INTO THE TRENCH, A HEAVY, TIGHTLY WOVEN CANVAS BAG OF SUITABLE SIZE BE PLACED OVER EACH END AND
THE PIPE LAYING CREW CANNOT PUT THE PIPE INTO TRENCH AND IN PLACE WITHOUT GETTING EARTH IN IT, THEN THE INSPECTOR MAY REQUIRE
39. EVERY PRECAUTION SHALL BE TAKEN TO PREVENT FOREIGN MATERIAL FROM ENTERING THE PIPE WHILE IT IS BEING PLACED IN THE TRENCH. IF
PERIOD SHALL BE THE RESPONSIBILITY OF THE DEVELOPER/CONTRACTOR.
ITS CONTRACTOR AT THEIR EXPENSE. DAMAGES TO STREETS, SIDEWALKS ETC. DUE TO FAILURE OF THE NEW WATER MAIN DURING THE WARRANTY
38. ANY MATERIAL THAT BECOMES DAMAGED BEFORE ACCEPTANCE OR FAILS WITHIN THE WARRANT PERIOD SHALL BE REPLACED BY THE DEVELOPER OR
ENGINEER.
DAMAGED, THE REPAIR SHALL BE MADE BY THE APPLICANT (DEVELOPER OR CONTRACTOR) AT THEIR EXPENSE IN A MANNER SATISFACTORY TO THE
37. PIPE SHALL BE SO HANDLED THAT THE COATING AND LINING WILL NOT BE DAMAGED. IF, HOWEVER, ANY PART OF THE COAT1NG OR LINING IS
GROUND.
SUCH A MANNER AS TO AVOID SHOCK OR DAMAGE. PIPE HANDLED ON A SKIDWAY SHALL NOT BE SKIDDED OR ROLLED AGAINST PIPE ALREADY ON THE
36. ALL PIPE, FITTINGS, VALVES, FIRE HYDRANTS, AND APPURTENANCES WHICH ARE LOADED OR UNLOADED BY HOIST OR SKIDS SHALL BE HANDLED IN
DATESIGNED (GA PROFESSIONAL ENGINEER SEAL)
Distribution System.
correct and In general compliance with existing Rules end Regulations Governing Installation of Water Line In the Atlanta Water
1 certify that the date reflected on this drawing has been verified In the field and to the best of my knowledge accurate and
Construction Administration containing the following statements:
b) Certificate: The final water plat will also contain a certificate signed by the Contractors, Engineer responsible for the
ALL DRAWING SHEETS IN A SET FOR A PROPOSED PROJECT SHALL BE OF THE SAME
tabular format to include description and accurate coordinate location. The size of the plans will be standard 24" x 36".
(I.e. fire hydrants, manholes, valves, pipe bends, etc.) are to be shown by applicable symbols on the drawings and also presented In
(I.e. property corners) which are labeled and tied to the Fulton County (FC) GPS monument network. All Infrastructure assets
the U.S. State Plane Coordinate System, NAD83 GA West Zone, US Survey Feet. All drawings must contain two reference pins
"as-built" locations of facilities determined by review or resurvey after construction. As-built drawings must be georeferenced to
the information previously outlined with the further provision that said final plat shall reflect In reproducible form containing
a) The proposed and final water line plat required under these provisions shall consist of a revised and corrected plan and profile
AS-BUILT PLAN WITH A GA PROFESSIONAL ENGINEER SEAL ATTACHED THAT MEETS THE FOLLOWING CONDITIONS:
67. PRIOR TO THE CITY OF ATLANTA FINAL INSPECTION AND ACCEPTANCE OF WORK, CONTRACTOR SHALL SUBMIT IN ELECTRONIC AND PAPER FORMAT A FINAL
66. PAYMENT FOR NEW FIRE HYDRANTS SHALL INCLUDE THE 6-INCH GATE VALVE AND CONNECTION TO THE MAIN
REMOVED FROM SITE AT NO ADDITIONAL COST.
65. ALL ABANDONED PIPE SHALL BE INSPECTED BY CONTRACTOR AND CONFIRMED AS ASBESTOS FREE. ANY ABANDONED PIPE CONTAINING ASBESTOS SHALL BE
HYDRANTS SHALL BE BORNE BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE CITY.
FAlLS TO NOTIFY THE CITY IN WRITING PRIOR TO CONSTRUCTION ALL COSTS ASSOCIATED WITH THE REPAIR OR REPLACEMENT OF DAMAGED OR LEAKING
64. CONTRACTOR SHALL NOTIFY CITY OF ANY LEAKING OR DAMAGED FIRE HYDRANTS IN WRITING PRIOR TO START OF CONSTRUCTION. IF THE CONTRACTOR
EXISTING METER, INCLUDING BYPASS AND VAULT.
63. CONTRACTOR SHALL INCLUDE CONSTRUCTION OF A NEW VAULT AS NEEDED AT NO ADDITIONAL COST TO OWNER FOR PAY ITEM 670-9737 RELOCATE
PLANS ARE TO BE PREPARED IN ACCORDANCE WITH REQUIREMENTS OF THE CITY OF ATLANTA DEPARTMENT OF WATERSHED MANAGEMENT.
62. THE CONTRACTOR SHALL PROVIDE A SET OF AS-BUILT PLANS FOR ALL WATER UTILITY INFRASTRUCTURE RELOCATION ADJUSTMENT WORK. AS-BUILT
OF WATERSHED MANAGEMENT WILL HAVE THIRTY (30) DAYS TO REVIEW AND RESPOND TO ALL SUBMITTAL'S.CITY OF ATLANTA DEPARTMENT
INFRASTRUCTURE DURING CONSTRUCTION. THIS PLAN SHALL BE SUBMITTED TO THE CITY OF ATLANTA -DEPARTMENT OF WATERSHED MANAGEMENT. THE
FOR APPROVAL, A DETAILED PLAN OUTLYING THE PROPOSED METHOD OF PROTECTING AND SUPPORTING THE EXISTING WATER MAIN AND WATER UTILITY
61. CARE SHALL BE TAKEN TO PROTECT THE EXISTING WATER UTILITY INFRASTRUCTURE DURING CONSTRUCTION. THE CONTRACTOR IS REQUIRED TO SUBMIT,
PROJECT PRE-CONSTRUCTION MEETING.
6Q, THE CITY OF ATLANTA CONSTRUCTION INSPECTION AND CONSTRUCTION MANAGEMENT CONTACT INFORMATION SHALL BE SUPPLIED AT THE TIME OF THE
(404) 546-3240.
OR REPORTING. FOR PROJECT SPECIFIC INFORMATION, PLEASE CONTACT THE CITY OF ATLANTA DEPARTMENT OF WATERSHED MANAGEMENT AT
59. THE CONTRACTOR SHALL NOTIFY THE CITY OF ATLANTA DEPARTMENT OF WATERSHED MANAGEMENT AT {404) 658-6500 FOR ANY EMERGENCY NOTIFICATIONS
VIA DOOR HANGERS AND/OR AUTOMATED PHONE MESSAGES PRIOR TO DISRUPTION.
SERVICE DISRUPTIONS. CONTRACTOR SHALL COORDINATE WITH THE DWM INSPECTOR TO ENSURE A 48 HOUR NOTICE 1S ISSUED; NOTICE TO CITIZENS
58. THE CONTRACTOR SHALL NOTIFY THE DWM INSPECTOR AND RECEIVE APPROVAL FROM THE DWM INSPECTOR AT LEAST 72 HOURS IN ADVANCE OF ANY
REQUIRED, TO SECURE THE REQUIRED COMPACT10N. THE METHOD USED FOR BACKFILLING SHALL BE SUBJECT TO THE APPROVAL OF THE INSPECTOR.
(DEVELOPER OR CONTRACTOR) SHALL MAKE THE NECESSARY REPAIRS AT THEIR OWN EXPENSE. THE BACKFILL MATERIAL MAY BE SLIGHTLY MOISTENED, IF
57. IF ANY SETTLEMENT OF THE EARTH IS OBSERVED AT ANY TIME WITHIN ONE (1) YEAR AFTER THE ACCEPTANCE OF THE PROJECT, THEN THE APPLICANT
(A.S.T.M. 0698).
56. ALL BACKFILL SHALL BE THOROUGHLY COMPACTED TO NOT LESS THAN 95% OF MAXIMUM DRY DENSITY AS DETERMINED BY A MODIFIED PROCTOR TEST
APPROVED BY THE INSPECTOR FOR BACKFILL.
PAVEMENT NO LARGER THAN 6-INCHES IN THE GREATEST DIMENSION, MAY BE USED PROVIDED THE EXCAVATION, AND EXCAVATED MATERIAL HAS BEEN
ABOVE THE TOP OF THE PIPE TO THE SUBGRADE OF THE PAVEMENT, EXCAVATED MATERIAL CONTAINING AN OCCASIONAL STONE OR BROKEN PIECE OF
MATERIAL IN THE BOTTOM OF THE TRENCH AND UP TO ONE (1) FOOT OVER THE TOP OF THE PIPE SHALL BE EARTH FILLED ONLY. FROM ONE (1) FOOT
FOR DUCTILE IRON PIPE, PIPE BEDDING CONSISTING OF SAND, GRAVEL SHALL BE PLACED IN BOTTOM OF TRENCH AND UP TO 1/8 PIPE DIA. BACKFILL 55.
GENERAL NOTES
44-0003
I-20 EB @ CS 2776/MAYNARD TERRACE
REVISION DATES
12/17/2020
USER:USCW670696
GPLOT-V8
gplotborder-V8i-PO-COA.tbl
C:\Users\uscw670696\Desktop\CAD\0013333\700 CAD\740 Sheets\0013333_44-0003.dgn
10:57:58 PM
GPLN10/23/2015
CHECKED:
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
DRAWING No.
Project No.
0013333
LEGEND AND ABBREVIATIONS
44-0004
I-20 EB @ CS 2776/MAYNARD TERRACE
U
N
D
E
R
G
R
O
U
N
D
O
V
E
R
H
E
A
D
EXISTING TO BE REMOVED
UTILITY LINECODES
TYPE OF UTILITYPROPOSED EXISTING PROPOSED TEMPORARY
UTILITY SYMBOLS
EXISTING PROPOSED TEMPORARY
HAND HOLE
TRANSFORMER
LIGHT POLE
MARKER
SPLICE BOX
CABINET
PHONE BOOTH
(aka "SLICK")
SUBCRIBER LOOP CARRIER
WELL
STAND PIPE
BACKFLOW PREVENTER
PRESSURE INDICATOR VALVE
AIR RELEASE VALVE
CLEANOUT
GREASE TRAP
VENT
AIR RELEASE VALVE
ELECTRIC MANHOLE
ELECTRIC METER
ELECTRIC BOX
CABLE TV MANHOLE
WATER VALVE
WATER METER
WATER MANHOLE
WATER VAULT
SANITARY SEWER MANHOLE
GAS PRESSURE REGULATOR
UTILITY POLE/GUY POLE
PETROLEUM VALVE
GAS VAULT
GAS MANHOLE
GAS VALVE
GAS METER
TELECOMMUNICATIONS MANHOLE
TELECOMMUNICATIONS PEDESTAL
CABLE TV PEDESTAL
SANITARY SEWER FORCE MAIN VALVE
WATER VALVE MARKER
##"W(C)
##"W
##
##
##
##
##
##
##
##
##
##
##
##
##
##
##
##
##
##
##
##
GAS TEST STATION
ELECTRIC (QL-D)
TELECOMMUNICATIONS (QL-D)
CABLE TV (QL-D)
WATER (QL-D)
WATER FOR LABELED PIPE SIZES (QL-D)
NON-POTABLE WATER (QL-D)
NON-POTABLE WATER FOR LABELED PIPE SIZES (QL-D)
STEAM (QL-D)
STEAM FOR LABELED PIPE SIZES (QL-D)
SANITARY SEWER WITH FLOW DIRECTION (QL-D)
SANITARY SEWER WITH FLOW DIRECTION FOR LABELED PIPE SIZES (QL-D)
SANITARY SEWER FORCE MAIN WITH FLOW DIRECTION (QL-D)
GAS (QL-D)
GAS FOR LABELED PIPE SIZES (QL-D)
PETROLEUM (QL-D)
PETROLEUM FOR LABELED PIPE SIZES (QL-D)
TRAFFIC CONTROL (QL-D)
##"W
##"W(B)
GUY ANCHOR
(INCLUDES ASSOCIATED VALVE)
FIRE HYDRANT ASSEMBLY##"W(C)
##
##
##
##"W
##"W(B)
##
##
##
##
##
##
##
##
##
##
##
##
ELECTRIC (QL-C)
ELECTRIC (QL-B)
TELECOMMUNICATIONS (QL-C)
TELECOMMUNICATIONS (QL-B)
CABLE TV (QL-C)
CABLE TV (QL-B)
WATER (QL-C)
WATER (QL-B)
WATER FOR LABELED PIPE SIZES (QL-C)
WATER FOR LABELED PIPE SIZES (QL-B)
NON-POTABLE WATER (QL-C)
NON-POTABLE WATER (QL-B)
NON-POTABLE WATER FOR LABELED PIPE SIZES (QL-C)
NON-POTABLE WATER FOR LABELED PIPE SIZES (QL-B)
STEAM (QL-C)
STEAM (QL-B)
STEAM FOR LABELED PIPE SIZES (QL-C)
STEAM FOR LABELED PIPE SIZES (QL-B)
SANITARY SEWER WITH FLOW DIRECTION (QL-C)
SANITARY SEWER WITH FLOW DIRECTION (QL-B)
SANITARY SEWER WITH FLOW DIRECTION FOR LABELED PIPE SIZES (QL-C)
SANITARY SEWER WITH FLOW DIRECTION FOR LABELED PIPE SIZES (QL-B)
SANITARY SEWER FORCE MAIN WITH FLOW DIRECTION (QL-C)
SANITARY SEWER FORCE MAIN WITH FLOW DIRECTION (QL-B)
GAS (QL-C)
GAS (QL-B)
GAS FOR LABELED PIPE SIZES (QL-C)
GAS FOR LABELED PIPE SIZES (QL-B)
PETROLEUM (QL-C)
PETROLEUM (QL-B)
PETROLEUM FOR LABELED PIPE SIZES (QL-C)
PETROLEUM FOR LABELED PIPE SIZES (QL-B)
TRAFFIC CONTROL (QL-C)
TRAFFIC CONTROL (QL-B)
UNKNOWN UTILITY FOUND IN SUE INVESTIGATION (QL-B)
ELECTRIC
ELECTRIC/TRAFFIC CONTROL
GUY WIRE
TRAFFIC CONTROL
ELECTRIC/CABLE TV
ELECTRIC/CABLE TV/TRAFFIC CONTROL
CABLE TV
CABLE TV/TRAFFIC CONTROL
ELECTRIC/TELECOMMUNICATIONS
ELECTRIC/TELECOMMUNICATIONS/TRAFFIC CONTROL
TELECOMMUNICATIONS
TELECOMMUNICATIONS/TRAFFIC CONTROL
ELECTRIC/TELECOMMUNICATIONS/CABLE TV
ELECTRIC/TELECOMMUNICATIONS/CABLE TV/TRAFFIC CONTROL
TELECOMMUNICATIONS/CABLE TV/TRAFFIC CONTROL
SIGNAL/BUTTON POST
TRAFFIC CONTROL PEDESTRIAN
ELECTRIC COMMUNICATIONS BOX
TRAFFIC CONTROL MANHOLE/
REFER TO TRAFFIC SIGNAL PLANS
TRAFFIC CONTROL INFORMATION
FOR PROPOSED/TEMPORARY
REFER TO TRAFFIC SIGNAL PLANS
TRAFFIC CONTROL INFORMATION
FOR PROPOSED/TEMPORARY
QUALITY LEVELS AND DEFINITIONS
TELEPHONE PAIR SIZE TELEPHONE CABLE DIAMETER
101 - 2400
0.50 TO 2.00 IN5 - 100
UP TO 3.50 IN
TELEPHONE PAIR SIZE TABLE
QL-D DEPICTED ACCORDING TO UTILITY RECORD INFORMATION AND IN-FIELD VISUAL INSPECTION. NO ELECTRONIC DESIGNATING INFORMATION WAS OBTAINED.
QL-C EXISTING UTILITY STRUCTURES HAVE BEEN FIELD LOCATED AND SURVEYED TO ASSIST IN DEPICTING THE UTILITIES SHOWN ON RECORDS. NO ELECTRONIC DESIGNATING INFORMATION WAS OBTAINED.
BY THE PROJECT AND REDUCED ONTO PLAN DOCUMENTS.
SUBSURFACE UTILITIES. QL-B DATA SHOULD BE REPRODUCIBLE BY SURFACE GEOPHYSICS AT ANY POINT OF THEIR DEPICTION. THIS INFORMATION IS SURVEYED TO APPLICABLE TOLERANCES DEFINED
QL-B INFORMATION WAS OBTAINED THROUGH THE APPLICATION OF APPROPRIATE SURFACE GEOPHYSICAL METHODS TO DETERMINE THE EXISTENCE AND APPROPRIATE HORIZONTAL POSITION OF THE
EXACT LOCATION AND POSITION OF THE UTILITY LINE.
NONDESTRUCTIVE EQUIPMENT IN A MANNER AS TO CAUSE NO DAMAGE TO THE UTILITY LINE. AFTER EXCAVATING A TEST HOLE, A FIELD SURVEY SHALL BE PERFORMED TO DETERMINE THE
QL-A OBTAIN PRECISE HORIZONTAL AND VERTICAL POSITION OF THE UTILITY LINE BY EXCAVATING A TEST HOLE. THE TEST HOLE SHALL BE DONE USING VACUUM EXCAVATION OR COMPARABLE
POLE ID
QUALITY LEVEL (QL) DELINEATION
SANITARY SEWER MANHOLE (SSMH) ID
END OF INFORMATION
TEST HOLE (QL-A ONLY)
UTILITY INVESTIGATION
LIMITS OF OVERHEAD AND SUBSURFACE
(UTILITY IMPACT ANALYSIS (UIA) ONLY)
CONFLICT LOCATION
MISCELLANEOUS
UTILITY LINE 3
UTILITY LINE 2
UTILITY LINE 1
12
3
MULTI-UTILITY IDENTIFICATION
1
3
2
UTILITY LINE 3
UTILITY LINE 2
UTILITY LINE 1
END OF UTILITY
123
A01
TH
EOI
C123
TELECOMMUNICATIONS/CABLE TV
ABBREVIATIONS
WATER SERVICE LINEWSL
WATER MAINWM
VITRIFIED CLAY PIPEVCP
TRANSITE (ASBESTOS) DUCTTRD
TERRA COTTA PIPETCP
SERVICE, UNKNOWN SIZE/TYPESVC
FIBER STRAND SIZESTR
SINGLE TILE DUCTSTD
SPLIT DUCTSD
FSINGLE CREOSOTE PINE DUCTSCP
SCREEN CABLESC
SANITARYSAN
RESTRAINED JOINTRJ
POLY VINYL CHLORIDEPVC
PROPOSEDPR
POLYETHYLENEPET
MULTIPLE TILE DUCTMTD
MANHOLEMH
MULTIPLE CONCRETE DUCTMCD
GATE VALVEGV
FIBER OPTIC CABLEFOC
EXISTINGEX
DUCTILE IRON PIPEDIP
CONCRETE CONC
CAST IRON PIPECIP
ASBESTOS CONCRETE PIPEACP
3 PHASE ELECTRIC3PH
REVISION DATES
12/17/2020
USER:USCW670696
GPLOT-V8
gplotborder-V8i-PO-COA.tbl
C:\Users\uscw670696\Desktop\CAD\0013333\700 CAD\740 Sheets\0013333_44-0004.dgn
10:58:02 PM
GPLN10/23/2015
CHECKED:
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
DRAWING No.
Project No.
0013333
UTILITY RELOCATION PLANS
44-0005
I-20 EB @ CS 2776/MAYNARD TERRACE
B
B
3/4" WATER SERVICE LINE
CUT AND CAP EXISTING
REMOVE EXISTING WATER METER
STA 107+01, 17' RT
1-8" DI 45-DEGREE BEND
TO FINISHED GRADE
ADJUST EX SAN SEWER MANHOLE
STA 107+82, 0' LT/RT
3/4" WATER SERVICE LINE
INSTALL 27 LF OF
INSTALL WATER METER
STA 107+97, 19' RT
TO FINISHED GRADE
ADJUST EX SAN SEWER MANHOLE
STA 107+88, 0' LT/RT
INSTALL 8" GATE VALVE
STA 107+21, 9' LT
TO FINISHED GRADE
ADJUST EX FIRE HYDRANT
STA 107+04, 17' LT1-8" DI 45-DEGREE BEND
OF 8" DIP WATER MAIN
BEGIN INSTALLATION FOR 450 LF
WATER MAIN WITH SOLID SLEEVE
CONNECT TO EXISTING 8" CI
STA 107+14, 9' RT
TO FINISHED GRADE
ADJUST EX WATER VALVE BOX
STA 107+06, 10' LT
TO FINISHED GRADE
ADJUST EX WATER METER BOX
STA 107+00, 19' LT (SEE NOTE 1)
1-8" DI CAP
8" CI WATER MAIN
GROUT FILL EXISTING
REVISION DATES
12/17/2020
USER:USCW670696
GPLOT-V8
gplotborder-V8i-PO-COA.tbl
C:\Users\uscw670696\Desktop\CAD\0013333\700 CAD\740 Sheets\0013333_44-0005.dgn
10:58:21 PM
GPLN10/23/2015
CHECKED:
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
20
SCALE IN FEET
0 40 80
DRAWING No.
Project No.
0013333
EASEMENT FOR CONSTR
EASEMENT FOR CONSTR OF SLOPES
EASEMENT FOR CONSTR OF DRIVES
CONSTRUCTION LIMITS
& MAINTENANCE OF SLOPES
C F
REQUIRED R/W LINE
PROPERTY AND EXISTING R/W LINE PL
ORANGE BARRIER FENCE
LIMIT OF ACCESS
BEGIN LIMIT OF ACCESS............BLA
END LIMIT OF ACCESS..............ELA
REQ'D R/W & LIMIT OF ACCESS
(SEE ERIT TABLE)
ESA - ENV. SENSITIVE AREA
EXISTING R/W
P L P L
P L
EXI
STI
NG
R/
W
PL
EXI
ST.
R/
W
EXISTING R/W
P LP L
LP
P L
P L
P L
EXI
STI
NG
R/
W
EXI
STI
NG
R/
W
2
1
3
4
5
REQ'D R/W REQ'D R/W
REQ'D R/W
REQ'D R/W
6' FE
NCE
5' FE
NCE
EC
NE
F '
4
4' FE
NCE
A07
A08
SV
C
SVC
TO SSMH A09
2"PLAS
UN
REI
NF
OR
CE
D
8"
CO
NC
UNREINFORCED
8" CONC
8"CI6"CI
SVCSVC
THIS LOCATION
8" CI TO 6" CI APPROX.
EX. WM TRANSITIONS FROM
103
+00
104
+00
105
+00
106
+00
108
+00
107
+00
CONSTRUCTION c
MAYNARD TERRACE AVEA6
A5.2
18"
18"
SEE
DR
AWI
NG
No. 44-0006
MATC
H LI
NE ST
A. 108+50
NOTES:
PROPOSED STORM DRAINAGE PIPE.
AND LOCATE 8" DI CAP AT LIMIT OF CONFLICT WITH
STORM DRAINAGE PIPE. REMOVE EXISTING WATER MAIN
WATER MAIN AND EXTENT OF CONFLICT WITH PROPOSED
CONTRACTOR TO VERIFY LOCATION OF EXISTING 8" CI 1.
UTILITY RELOCATION PLANS
44-0006
I-20 EB @ CS 2776/MAYNARD TERRACE
B
B
TO FINIS
HED
GRADE
ADJUS
T EXIS
TING
WATER V
ALVE
STA
121+
36,
95'
LT
WITH THRUST BLOCK
INSTALL FIRE HYDRANT
STA 201+97, 45' RT
1" WATER SERVICE LINE
CUT AND CAP EXISTING
REMOVE EXISTING WATER METER
STA 109+41, 44' RT
1" WATER SERVICE LINE
INSTALL 10 LF OF
INSTALL WATER METER
STA 109+06, 64' RT
1" WATER SERVICE LINE
CUT AND CAP EXISTING
REMOVE EXISTING WATER METER
STA 108+75, 13' LT
1-6" DI 90-DEGREE BEND
1-8" DI 22.5-DEGREE BEND
1-8" DI 45-DEGREE BEND
1-8" DI 45-DEGREE BEND
1-8" DI 6.125-DEGREE BEND
1-8" DI CAP
OF 8" DIP WATER MAIN
BEGIN INSTALLATION FOR 310 LF
1-8"x8" DI TEE
INSTALL 8" GATE VALVE
STA 111+06, 22' RT
INSTALL 8" GATE VALVE
STA 109+56, 64' RT
3/4" WATER SERVICE LINE
INSTALL 43 LF OF
INSTALL WATER METER
STA 210+26, 35' RT
1" WATER SERVICE LINE
INSTALL 75 LF OF
INSTALL WATER METER
STA 108+89, 41' LT
INSTALL 6" GATE VALVE
STA 202+06, 1' LT
IN PLACE
ABANDON EX WATER VALVE
STA 109+64, 9' LT
INSTALL 70 LF OF 6" DIP
1-8"x6" DI TEE
3/4" WATER SERVICE LINE
CUT AND CAP EXISTING
REMOVE EXISTING WATER METER
STA 201+39, 31' RT
2-8" DI 22.5-DEGREE BENDS
2-8" DI 45-DEGREE BENDS
OF 8" DIP WATER MAIN
END INSTALLATION FOR 450 LF
WATER MAIN WITH SOLID SLEEVE
CONNECT TO EXISTING 8" CI
STA 111+63, 21' RT
8" CI WATER MAIN
GROUT FILL EXISTING
8" CI WATER MAIN
GROUT FILL EXISTING
CUT AND CAP EX. 6" WM
RETURN TO COA DWM
REMOVE EX. FIRE HYDRANT
STA 109+94, 10' LT
REVISION DATES
12/17/2020
USER:USCW670696
GPLOT-V8
gplotborder-V8i-PO-COA.tbl
C:\Users\uscw670696\Desktop\CAD\0013333\700 CAD\740 Sheets\0013333_44-0006.dgn
10:58:39 PM
GPLN10/23/2015
CHECKED:
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
20
SCALE IN FEET
0 40 80
DRAWING No.
Project No.
0013333
EASEMENT FOR CONSTR
EASEMENT FOR CONSTR OF SLOPES
EASEMENT FOR CONSTR OF DRIVES
CONSTRUCTION LIMITS
& MAINTENANCE OF SLOPES
C F
REQUIRED R/W LINE
PROPERTY AND EXISTING R/W LINE PL
ORANGE BARRIER FENCE
LIMIT OF ACCESS
BEGIN LIMIT OF ACCESS............BLA
END LIMIT OF ACCESS..............ELA
REQ'D R/W & LIMIT OF ACCESS
(SEE ERIT TABLE)
ESA - ENV. SENSITIVE AREA
STREAM 1PERENNIAL
PL
PL
R/
WE
XI
ST.
EXI
ST.
R/
W
EXI
ST.
R/
W
&
L/
A
EXIST. R/W
R/
W
&
L/
A
EXI
ST.
4
5
6
7
REQ'D R/W
REQ'D
R/W
REQ'D R/W
CULVERTF/L = 925.97'
6'X6' (WxH)
ECNE
F '
6
ECNEF '6
ECNEF '6
ECNEF '6
ECNEF '6
RGM
RGM
TO BRIDGEWATER LINE ATTACHED
SVC
SVC
2" PL
AS
8"CI
SVC
8"CI
8"CI8"CI
SVC
SVC W(B)8"CI
8"CI
110
+00
111
+00
112
+00
113
+00
202+00
109+00
MAYNARD TERRACE AVECONSTRUCTION c
MAYNARD TERRACE
AVE
CONSTRUCTION
c
CO
NS
TR
UC
TI
ON c
MC
PH
ER
SO
N
AV
E
I-20
EB
OFF
RA
MP
CO
NS
TR
UC
TI
ON c
302+00
303+00
A1
A2
A3
A4
A5
A5.1
A3.2
A3.1
A3.3
A3.4
A3.5
A3.3.1
A4.1
A4.2
18"
18"
18"
18"
18"
18"
18"
18"
18"
18"
24"
24"
MATCH L
INE S
TA. 20
1+00
SEE DR
AWING N
o. 44-
0008
SEE DRA
WING No. 44-0005
MATCH LINE STA. 108+50
MAT
CH LI
NE ST
A. 113+50
SEE
DR
AWI
NG
No. 44-0007
MATCH LINE STA. 302+50
SEE DRAWING No. 44-0008
NOTES:
DRAIANGE PIPE.
WATER MAIN AND EDGE OF PROPOSED STORM
OF 18-INCHES BETWEEN EDGE OF PROPSOED
MAINTAIN A MINIMUM VERTICAL CLEARANCE 1.
UTILITY RELOCATION PLANS
44-0007
I-20 EB @ CS 2776/MAYNARD TERRACE
REVISION DATES
12/17/2020
USER:USCW670696
GPLOT-V8
gplotborder-V8i-PO-COA.tbl
C:\Users\uscw670696\Desktop\CAD\0013333\700 CAD\740 Sheets\0013333_44-0007.dgn
10:58:56 PM
GPLN10/23/2015
CHECKED:
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
20
SCALE IN FEET
0 40 80
DRAWING No.
Project No.
0013333
EASEMENT FOR CONSTR
EASEMENT FOR CONSTR OF SLOPES
EASEMENT FOR CONSTR OF DRIVES
CONSTRUCTION LIMITS
& MAINTENANCE OF SLOPES
C F
REQUIRED R/W LINE
PROPERTY AND EXISTING R/W LINE PL
ORANGE BARRIER FENCE
LIMIT OF ACCESS
BEGIN LIMIT OF ACCESS............BLA
END LIMIT OF ACCESS..............ELA
REQ'D R/W & LIMIT OF ACCESS
(SEE ERIT TABLE)
ESA - ENV. SENSITIVE AREA
6'X6' (WxH)
F/L = 918.72'
CULVERT
ECNEF '6
ECNEF '6
15" ACP
24"
ACP
ACP
24"
8"CI
11
4+
00
11
5+
00
11
6+
00
117
+00
MAYNARD TERRACE AVE
CONSTRUCTION c
SEE
DR
AWI
NG
No. 24-0002
MAT
CH LI
NE ST
A. 113+50
ASSETS ON THIS SHEET.
WITH CITY OF ATLANTA WATER OR SEWER
THERE IS NO PROPOSED WORK ASSOCIATED1.
NOTES:
UTILITY RELOCATION PLANS
44-0008
I-20 EB @ CS 2776/MAYNARD TERRACE
1-8" DI 45-DEGREE BEND
1-8" DI 45-DEGREE BEND
INSTALL 8" GATE VALVE
STA 201+06, 20' LT
OF 8" DIP WATER MAIN
END INSTALLATION FOR 310 LF
WATER MAIN WITH SOLID SLEEVE
CONNECT TO EXISTING 8" CI
STA 200+31,23' LT
(SEE NOTE 1)
1-8" DI CAP
8" CI WATER MAIN
GROUT FILL EXISTING
REVISION DATES
12/17/2020
USER:USCW670696
GPLOT-V8
gplotborder-V8i-PO-COA.tbl
C:\Users\uscw670696\Desktop\CAD\0013333\700 CAD\740 Sheets\0013333_44-0008.dgn
10:59:13 PM
GPLN10/23/2015
CHECKED:
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
20
SCALE IN FEET
0 40 80
DRAWING No.
Project No.
0013333
EASEMENT FOR CONSTR
EASEMENT FOR CONSTR OF SLOPES
EASEMENT FOR CONSTR OF DRIVES
CONSTRUCTION LIMITS
& MAINTENANCE OF SLOPES
C F
REQUIRED R/W LINE
PROPERTY AND EXISTING R/W LINE PL
ORANGE BARRIER FENCE
LIMIT OF ACCESS
BEGIN LIMIT OF ACCESS............BLA
END LIMIT OF ACCESS..............ELA
REQ'D R/W & LIMIT OF ACCESS
(SEE ERIT TABLE)
ESA - ENV. SENSITIVE AREA
ST
RE
AM 1
PE
RE
NNI
AL
ST
RE
AM 1
PE
RE
NNI
AL
PL
PL
PL
PL
PL
EXISTING R
/W
EXISTI
NG R/
W
PL
PL
EXISTING R/W & L/A
R/W & L/A
EXIST.
6
7
REQ'D R/
W
6'X6' (WxH)
6'X6'(WxH)
CULVERT
F/L = 926.84'
CULVERT
F/L = 926.95'
ECNEF '6
4 FT FENCE
A02
A03
A04
4" PLA
S
SVC
SVC
SVC
TO SS
MH A0
5
UNREINFORCED
8" CONC
UN
REI
NF
OR
CE
D
15"
CO
NC
UN
REI
NF
OR
CE
D
15"
CO
NC
8"CI
SVC W(B)
SVC
8"CI
8"
DIP
8" DIP
200
+00
MCPHERSON AVE
CONSTRUCTION cI-20 EB OFF RAMP
297
+52
298
+00
299
+00
300
+00
301
+00
CONSTRUCTION c
SEE
DR
AWI
NG
No. 44-0006
MATC
H LI
NE ST
A. 201+00
MATC
H LI
NE ST
A. 301+50
SEE
DR
AWI
NG
No. 44-0006
NOTES:
WALL.
CONFLICT WITH PROPOSED RETAINING
LOCATE 8" DI CAP AT LIMIT OF
REMOVE EXISTING WATER MAIN AND
RETAINING WALL FOOTING.
AND EXTENT OF CONFLICT WITH
OF EXISTING 8" CI WATER MAIN
CONTRACTOR TO VERIFY LOCATION 1.
VOLUME
CUBIC YARD
MINIMUM
DIMENSIONS IN FEET FOR CONCRETE BLOCKING
24"
20"
16"
12"
8"
6" 1.0
1.0
1.0
2.0
2.0
3.0
1.0
1.25
2.0
3.0
3.0
4.0 22"
19"
15"
11"
7"
7" 1.0
1.0
2.0
2.0
3.0
3.0
0.03
0.04
0.1
0.3
0.5
0.8
24"
20"
16"
12"
8"
6" 1.0
1.0
2.0
2.0
3.0
4.0
1.5
2.0
3.0
4.0
5.0
6.0 22"
19"
15"
11"
7"
7" 1.0
2.0
2.0
3.0
3.0
4.0
0.04
0.1
0.3
0.6
0.1
2.3
24"
20"
16"
12"
8"
6" 1.5
2.0
2.0
3.0
4.0
5.0
2.0
3.0
4.0
5.0
6.0
8.0 22"
19"
15"
11"
7"
7" 1.5
2.0
3.0
4.0
5.0
6.0
0.11
0.3
0.7
1.4
2.8
5.0
24"
20"
16"
12"
8"
6" 1.75
2.0
4.0
4.0
5.0
6.0
2.5
3.0
6.0
7.0
8.0
10.0 22"
19"
15"
11"
7"
7" 2.0
3.0
4.0
5.0
7.0
8.0
0.2
0.4
2.1
3.1
5.3
10.5
24"
20"
16"
12"
8"
6" 1.5
2.0
2.0
3.0
4.0
5.0
2.0
3.0
4.0
5.0
7.0
8.0 22"
19"
15"
11"
7"
7" 1.75
2.0
4.0
5.0
6.0
7.0
0.13
0.3
0.8
1.8
3.9
5.5
BEND SIZE A B C D
4111
2122
45
90
PLUGS
AND
TEES
D
1/
2-
D
BY THE ENGINEER BEFORE THRUST BLOCK
SOIL CONDITIONS SHALL BE VERIFIED
DESIGN IS IMPLEMENTED.
NOTES:
SECTION A
TYPICAL HORIZONTAL THRUST BLOCK
B
AC
A
1/2 O.D.
A
3000 P.S.I. HIGH EARLY.
CONCRETE SHALL BE CLASS B,
PER SQUARE INCH TEST PRESSURE.
FOOT SOIL BEARING PRESSURE AND 250 LBS.
BASED ON 2000 POUNDS PER SQUARE
DIMENSION OF THRUST BLOCK IS
1.
2.
3.
35
W
ELEVATION
A
B
C
A
1/2" O.D.
A
A
VOLUME
CUBIC YARD
MINIMUM
DIMENSIONS IN FEET FOR CONCRETE BLOCKING
24"
20"
16"
12"
8"
6" 1.0
1.0
1.0
2.0
2.0
3.0
1.0
1.25
2.0
3.0
3.0
4.0 22"
19"
15"
11"
7"
7" 1.0
1.0
2.0
2.0
3.0
3.0
0.03
0.04
0.1
0.3
0.5
0.8
24"
20"
16"
12"
8"
6" 1.0
1.0
2.0
2.0
3.0
4.0
1.5
2.0
3.0
4.0
5.0
6.0
7"
7"
11"
15"
19"
22"
1.0
2.0
2.0
3.0
3.0
4.0
0.04
0.1
0.3
0.6
1.0
2.3
24"
20"
16"
12"
8"
6" 1.5
2.0
2.0
3.0
4.0
5.0
2.0
3.0
4.0
5.0
6.0
8.0 22"
19"
15"
11"
7"
7" 1.5
2.0
3.0
4.0
5.0
6.0
0.11
0.3
0.7
1.4
2.8
5.0
24"
20"
16"
12"
8"
6" 1.75
2.0
4.0
4.0
5.0
6.0
2.5
3.0
6.0
7.0
8.0
10.0 22"
19"
15"
11"
7"
7" 2.0
3.0
4.0
5.0
7.0
8.0
0.2
0.4
2.1
3.1
5.3
10.5
24"
20"
16"
12"
8"
6" 1.5
2.0
2.0
3.0
4.0
5.0
2.0
3.0
4.0
5.0
7.0
8.0 22"
19"
15"
11"
7"
7" 1.75
2.0
4.0
5.0
6.0
7.0
0.13
0.3
0.5
1.5
3.5
5.5
BEND SIZE A B C D
4111
2122
45
90
PLUGS
AND
TEES
D
1/2-D
SECTION A
3000 P.S.I. HIGH EARLY.
3. CONCRETE SHALL BE CLASS B,
PRESSURE.
250 LBS. PER SQUARE INCH TEST
FOOT SOIL BEARING PRESSURE AND
BASED ON 2000 POUNDS PER SQUARE
2. DIMENSION OF THRUST BLOCK IS
ELEVATION
DESIGN IS IMPLEMENTED.
CONDITIONS BEFORE THRUST BLOCK
1. ENGINEER SHALL VERIFY SOIL
NOTES:
TYPICAL DOWNWARD THRUST BLOCK34
W
A
A
PROFILE
SECTION A
MIN.
3"
MIN.
3"
BRACE
BRACE
"21 3
ENGINEER
BY
DETERMINED
SHALL BE
LADDER
HEIGHT OF
PLAN
LC
BOLT SIZE AND NUMBER OF BOLTS SHALL
BE DETERMINED BY SIZE OF PIPE. (SEE
CHART)
FLAT IRON SHALL BE 12" X 3" UP TO 12" PIPE. 16" TO 24" PIPE
SHALL HAVE 34 " X 4" FLAT IRON AND HAVE (2) TWO BOLTS PER SIDE
BY ENGINEER
BE DETERMINED
DEADMAN SHALL
DIMENSIONS OF
VOLUME
CUBIC YARD
DEADMAN DETAILS
1
1
2
2
2
2
2
58" X 3"
58" X 3"
34" X 4"
34" X 4"
(2)34" X 5"
(2)34" X 5"
(2)34" X 6"
1
1
2
2
2
2
2
1
1
2
2
2
2
2
1
1
2
2
2
2
2
BEND SIZEBOLTS
OF
SIZE
4111
2122
45
90
24"
20"
16"
12"
10"
8"
6"
24"
20"
16"
12"
10"
8"
6"
24"
20"
16"
12"
10"
8"
6"
24"
20"
16"
12"
10"
8"
6"
LADDERS
OF
NUMBERS
0.3
0.6
1.0
1.4
2.4
3.8
5.3
0.7
1.2
1.7
2.7
4.8
7.4
10.3
1.2
2.2
3.3
4.3
8.8
13.7
19.8
1.8
3.1
5.3
7.0
12.4
19.4
22.0
HIGH EARLY.
3. CONCRETE SHALL BE CLASS B, 3000 P.S.I.
TEST PRESSURE.
PRESSURE AND 250 LBS. PER SQUARE INCH
POUNDS PER SQUARE FOOT SOIL BEARING
2. DESIGN OF THRUST BLOCK IS BASED ON 2000
BEFORE THRUST BLOCK DESIGN IS IMPLEMENTED.
1. ENGINEER SHALL VERIFY SOIL CONDITIONS
NOTES:
34A
W
THRUST DEADMAN
TYPICAL UPWARD
" X 6"43(2)
" X 5"43(2)
" X 5"43(2)
" X 4"43
" X 4"43
" X 3"85
" X 3"85
" X 6"43(2)
" X 5"43(2)
" X 5"43(2)
" X 4"43
" X 4"43
" X 3"85
" X 3"85
" X 6"43(2)
" X 5"43(2)
" X 5"43(2)
" X 4"43
" X 4"43
" X 3"85
" X 3"85
FOR TRENCH DETAIL
SEE DETAIL W/47A
EX. CONCRETE
PAVEMENT
6" GRADED AGGREGATE BASE
12" CUT BACK
TYP. EACH SIDE
PAVEMENT
EXISTING ASPHALT
6" GRADED AGGREGATE BASE
12" CUT BACK
TYP. EACH SIDE
CONCRETE WITH ASPHALT OVERLAY
CONCRETE PAVEMENT
CLASS "B"
10" MIN. CONCRETE
AND PAVEMENT REPLACEMENT
ASPHALT & CONCRETE STREETCUT7
G
LIMIT OF PAVEMENT
PAYMENT WIDTH
LIMIT OF PAVEMENT
PAYMENT WIDTH
ROUGH CONCRETE FINISH
VERTICAL EDGE (TYP)
FINAL SAW CUT
TACK COAT
SURFACE COURSE
2" TYPE "E"
VERTICAL EDGE (TYP)
INITIAL SAW CUT
CLASS "B"
8" MIN. CONCRETE
FOR TRENCH DETAIL
SEE DETAIL W-47A
PIPE O.D. +2'-0"
MAX.
MAX.
PIPE O.D. +2'-0"
VERTICAL EDGE(TYP.)
FINAL SAW CUT
VERTICAL EDGE(TYP.)
INITIAL SAW CUT
TYPICAL FIRE HYDRANT1
W
CONCRETE THRUST
BLOCK
6" GATE VALVE
& VALVE BOX
WATER MAIN
ANCHOR
COUPLING
EXISTING
GROUND 24" 0 x6" THICK
CONCRETE COLLAR
R/
W
18"
MIN.
FIRE HYDRANT
NOTES:
1. CONCRETE COLLAR NOT REQUIRED IF HYDRANT IS
2. STONE SHALL BE PLACED A MINIMUM 6" ABOVE DRAIN
PORTS, A MINIMUM 18" BELOW DRAIN PORTS, 15" LATERALLY
ON EACH SIDE OF SHOE AND 24" FROM BACK OF HYDRANT
TOWARD THE MAIN.
SURROUNDED BY CONCRETE SIDEWALK.
MINIMUM
4'-0" COVER
MAXIMUM
5'-0" COVER
21" MIN.
HYDRANT
TEE
CONCRETE THRUST
BLOCK
(SEE NOTE 1)
PIPEVALVE
MARKER BALL
MARKER BALL
TEE OR BEND
TYPICAL SECTION A-A
TRENCH
MARKER BALL
PIPE
(M
AX)
5'-
0"
4" MIN.
HAND BACKFILL
BALL
MARKER
TO 6" OVER
TYPICAL PLAN
62
W ELECTRONIC BALL MARKER DETAIL
A
A
A
A
(SEE NOTE 3)
CUT PIPE AND CAP
EARTH
UNDISTURBED
CUT PIPE AND CAP
(ITEM 16B)
SEE DETAIL W/36
THRUST BLOCK(SEE NOTE 2)
EXISTING VALVE
ABANDONED/KILLED
MAIN TO BE
EXISTING WATER
EARTH
UNDISTURBED
IN SERVICE
MAIN TO REMAIN
EXISTING WATER
(ITEM 7F)
AS SPECIFIED
VALVE TO BE ABANDONED
EXISTING IN LINE
61
W CUT AND PLUG/VALVE ABANDONMENT DETAIL
PLAN VIEW
4. OPEN VALVE WHEN DIRECTED BY ENGINEER.
PIPE AND POUR THRUST BLOCK AGAINST CAP.
3. WHERE VALVE DOES NOT EXIST, INSTALL CAP ON END OF
BLOCK AGAINST VALVE.
REMOVE COVER AND EXTENSION STEM AND POUR TRUST
2. IF VALVE EXISTS WITHIN LIMITS OF EXCAVATION, CLOSE VALVE
1. CLOSE VALVE PRIOR TO CUTTING AND PLUGGING MAIN.
NOTES:
AND 4)
(SEE NOTE 1
IN SERVICE
MAIN TO REMAIN
VALVE ON WATER
LIMIT OF EXCAVATION
12"
D
4'-
0"(
MIN.)
UNPAVED AREAPAVED AREA
EXISTING GROUND SURFACE
UNDISTURBED EARTH
FOUNDATION:
CRUSHED STONE
BEDDING/HAUNCHING:
12"
AND FOREIGN MATTER.
MATERIAL FREE OF ROCKS, STONES
INITIAL BACKFILL:
6" ABOVE EXISTING GRADE
MOUND BACKFILL
5'-
0"(
MA
X.)
EARTHROCK
X
PIPE
X= 12" MIN. WHEN D> 24"
X= 8" MIN. WHEN D < 21"
UNDISTURBED EARTH
FOUNDATION:
COMPACTED IN 6-INCH LAYERS
SUITABLE EXCAVATED MATERIAL,
FINAL BACKFILL:
G-7
REPLACEMENT DETAILS
SEE STREET CUT AND
47
W
TRENCH SECTION
DUCTILE IRON WATER MAIN
BASE
AGGREGATE
6" GRADED
AS DETERMINED BY ASTM-D698
OF ITS MAXIMUM DRY DENSITY
BE COMPACTED TO 95
ALL BACKFILL MATERIAL SHALL
NOTE:
>
ORIG. DATE: OCT. 2004
DATE: OCT. 2011
SCALE: N.T.S.
STANDARD DETAILS
TRENCH TERMINOLOGY
DETAIL NO. WR-G_TR003
AND SHOULD BE REVIEWED THOROUGHLY.
THIS DETAIL WAS TAKEN FROM THE CITY OF ATLANTA'S WEBSITE. IT MAY HAVE BEEN MODIFIED
DIA
METE
R
OUTSID
EPIP
E
BOTTOM OF
DITCH IF NO
FOUNDATION
REQUIRED
,
A.
G
A
56
81
74
81
ATNAL
T
S
NEG
R
USE
R
City of Atlanta REV.
FINAL BACKFILL
INTIAL BACKFILL
12"
(TRENCH STABILIZATION)
FOUNDATION IF REQUIRED
(DEPTH VARIES)
HAUNCHING
TRENCH SLOPE
MIN. HEIGHT START
BEDDING
ORIG. DATE: OCT. 2004
DATE: OCT. 2011
SCALE: N.T.S.
STANDARD DETAILS
TRENCH SECTION
TYPICAL WATERLINE
DETAIL NO. WR-G_TR001
AND SHOULD BE REVIEWED THOROUGHLY.
THIS DETAIL WAS TAKEN FROM THE CITY OF ATLANTA'S WEBSITE. IT MAY HAVE BEEN MODIFIED
THE ENGINEER, WARRANT THE NEED FOR ADDITIONAL TESTS.
CONSTRUCTION, UNLESS SOIL CONDITIONS OR CONSTRUCTION PRACTICES, IN THE OPINION OF
JOB, AND A MAXIMUM OF ONE REQUIRED TEST FOR 400 FEET OF LESS OF WATER MAIN
AND AT INTERVALS AS DETERMINED BY THE ENGINEER WITH A MINIMUM OF ONE TEST ON EACH
SIDEWALKS, DRIVES AND OTHER EXISTING OR PROPOSED PAVED AREAS AT VARYING DEPTHS
COMPACTION TEST: COMPACTION TEST WILL BE REQUIRED IN EXISTING OR PROPOSED STREETS, 3.
CLASSIFICATION. AS DETERMINED BY THE STANDARD PROCTOR TEST, ASTM D698.
COMPACTED AT NOT LESS THAN 98% OF THEIR OPTIMUM COMPACTION FOR ANY SPECIFIC SOIL
AMOUNT OF MOISTURE FOR PROPER COMPACTION, AND THESE MATERIALS SMALL BE
COMPACTION STANDARDS: ALL BACKFILL MATERIALS USED SHALL CONTAIN A SUFFICIENT 2.
MATERIAL BE PLACED IN TRENCHES.
THAN 12-INCHES IN DEPTH, PUDDLING WILL NOT BE PERMITTED, NOR WILL FROZEN OR WET
THOROUGHLY COMPACTED BEFORE BEGINNING ANOTHER LAYER. LAYERS SHALL BE NO MORE
COMPACTION: BACKFILLS SHALL BE BUILT UP IN LAYERS AND EACH LAYER SHALL BE 1.
NOTES:
9"WIDTH FOR REPAVING
ALLOWABLE TRENCH
A
PAVEMENT CUT-BACK
DETAIL 12"
DUCTILE IRON PIPE
BELL HOLE
DBA
CK
FIL
L
MA
TE
RIA
L
CO
VE
R
4'-
0"
MIN/ 5'-
0"
MA
X.
TRENCH SHALL BE EXCAVATED TO
DEPTH REQUIRED PROVIDING A UNIFORM
AND CONTINOUS BEARING AND
SUPPORT FOR THE PIPE OS SOLID AND
UNDISTURBED GROUND AT EVERY POINT
BETWEEN BELL OR COUPLING HOLES.FOR EXCAVATION IN POOR SOIL:
REMOVE UNSUITABLE MATERIAL
TO WIDTH AND DEPTH
DIRECTED. BEFORE PIPE IS
LAID, THE SUBGRADE SHALL BE
BACKFILLED WITH AN APPROVED
MATERIAL IN 3" LAYERS, EACH
LAYER SHALL BE THOROUGHLY
TAMPED TO 95% COMPACTION.
PIPE SIZE(NOMIANAL)
A
(MAXIMUM)
EARTH/ROCK
B
(MAXIMUM)
EARTH/ROCK
C D
MIN./MAX.
6" 3.50'/4.00' 2.00'/2.50' AS REQ'D 9"/12"
8" 3.50'/4.00' 2.00'/2.50' 9"/12"
4.00'/4.50' 2.50'/3.00' 9"/12"
4.50'/5.00' 3.00'/3.50' 9"/12"
9"/12"
5.00'/5.50' 9"/12"
5.50'/6.00' 9"/12"
6.00'/6.50' 9"/12"
7.00'/7.50' 9"/12"
12"
16"
20"
24"
30"
36"
48"
4.50'/5.00' 3.00'/3.50'
3.50'/4.00'
4.00'/4.50'
5.50'/6.00'
4.50'/5.00'
"
"
"
"
"
"
"
"
AND COMPACTED AS SPECIFIED.
AND THE BACKFILL TO BE PLACED
TO BE LAID AND JOINTED PROPERLY
B-WIDTH REQUIRED TO PERMIT PIPE
SUPPORT, SHEETING, BRACING, ETC.
PROVIDE FOR PLACING OF TIMBER
C-EXTRA WIDTH AS REQUIRED TO
B
C
,
A.
G
A
56
81
74
81
ATNAL
T
S
NEG
R
USE
R
City of Atlanta REV.
CONSTRUCTION DETAILS
44-0009
I-20 EB @ CS 2776/MAYNARD TERRACE
REVISION DATES
12/17/2020
USER:USCW670696
GPLOT-V8
gplotborder-V8i-PO-COA.tbl
C:\Users\uscw670696\Desktop\CAD\0013333\700 CAD\740 Sheets\0013333_44-0009_Details.dgn
10:59:20 PM
GPLN10/23/2015
CHECKED:
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
DRAWING No.
Project No.
0013333
ORIG. DATE: NOV. 2004
DATE: OCT. 2011
SCALE: N.T.S.
STANDARD DETAILS
VALVE BOX
TYPICAL UNDERGROUND
DETAIL NO. WR-G_VB001
AND SHOULD BE REVIEWED THOROUGHLY.
THIS DETAIL WAS TAKEN FROM THE CITY OF ATLANTA'S WEBSITE. IT MAY HAVE BEEN MODIFIED
WAT E R
CONCRETE COLLAR
CAST IRON LID
4 #4 REBARS
VALUE OPERATING NUT
VALVE OPERATOR
2' FT BELOW GRADE
WRENCH NUT
2 INCH SQUARE
GREATER THAN 4FT. DEEP
VALUE OPERATING NUT IS
EXTENSION STEM REQ. WHERE
SUPPORT BOX W/BRICK
NO CONTACT ON VALVE.
EXT. (AS REQ'D)
DUCTILE OR CAST IRON
CAST.IN.PLACE
PRECAST OR
24" SQ. OR 24" DIAM.
VALUE BOX
CAST IRON
9"8"
WRENCH NUT
FIT 2 INCH SQUARE
,
A.
G
A
56
81
74
81
ATNAL
T
S
NEG
R
USE
R
City of Atlanta REV.
VALVE BOX COVER
ORIG. DATE: OCT. 2004
DATE: OCT. 2011
SCALE: N.T.S.
STANDARD DETAILS
BOX ASSEMBLIES
TYPICAL 4"-12" VALVE
DETAIL NO. WR-G_VB002
AND SHOULD BE REVIEWED THOROUGHLY.
THIS DETAIL WAS TAKEN FROM THE CITY OF ATLANTA'S WEBSITE. IT MAY HAVE BEEN MODIFIED
4. WHEN COATING IS COMPLETE, LID SHALL FIT SNUGLY WITHOUT ROCKING.
ADHERE TO THE METAL AT ALL TEMPERATURES.
GLOSSY NOT BRITTLE WHEN COLD, NOT STICKY WHEN EXPOSED TO THE SUN, AND SHALL
AND SHALL THOROUGHLY COVER ALL METAL SURFACES. FINISHED COATING SHALL BE SMOOTH,
INDICATED IN A.W.W.A. SPECIFICATIONS C110 LATEST REVISION. COATING MAY BE APPLIED COLD
3. FINISHED CASTING SHALL BE COATED INSIDE AND OUTSIDE WITH COAL TAR PITCH VARNISH AS
FOUNDRY PRACTICE, CHIPPED AND GROUND AS NEEDED TO REMOVE FINS AND ROUGH PLACES.
2. CASTING SHALL BE TRUE AND FREE OF HOLES. THEY SHALL BE CLEANED ACCORDING TO GOOD
LATEST REVISION FOR CLASS 20 GREY IRON CASTINGS.
1. UNLESS NOTED OTHERWISE, CAST IRON SHALL CONFORM TO A.S.T.M. SPECIFICATIONS A48
NOTES:
4 1/
4"
DIA.
5 1/
2"
DIA.
6 1/
2"
DIA.
2"
7 1/2"
5/8"
1"
1/2"
7 3/8" DIA.
7" DIA.
6 1/2" DIA.
4 3/4" DIA.
4" DIA. 2"
PLAN
1/2"
SECTION
5/8"R
R1/4"
8" DIA.
6 3/4"
DIA.
3/4"
1 3/4"
12"
SPECIAL TOP SECTION
VALVE BOX
1/
2"1 1/4"
R1/2"
7 1/2"
2"
1/8"
1/8"
1/2"
6" DIA.
10" DIA.
7 5/8" DIA.
1/2"
9 1/2"
7 5/8"
6 3/4"
5/8"
8
1/
4"
5/8"
3/8"12"
2 1/2"
9 1/2" DIA.
18 1/2" DIA.
2"
2 1/4"
STANDARD TOP SECTION
VALVE BOX
1/8"
2 1/2"
,
A.
G
A
56
81
74
81
ATNAL
T
S
NEG
R
USE
R
City of Atlanta REV.
GENERAL NOTES:
METER BOX
WHEN COATING IS COMPLETE, LID SHALL FIT SNUGLY WITHOUT ROCKING.4.
SUN, AND SHALL ADHERE TO THE METAL AT ALL TEMPERATURES.
AND SHALL BE SMOOTH, GLOSSY, NOT BRITTLE WHEN COLD, NOT STICKY WHEN EXPOSED TO THE
INDICATED IN A.W.W.A. SPECIFICATIONS C110, LATEST REVISION. COATING MAY BE APPLIED COLD
FINISHED CASTINGS SHALL BE COATED INSIDE AND OUTSIDE WITH COAL TAR PITCH VARNISH AS 3.
FOUNDRY PRACTICE, CHIPPED AND GROUND AS NEEDED TO REMOVE FINS AND ROUGH PLACES.
CASTINGS SHALL BE TRUE AND FREE OF HOLES. THEY SHALL BE CLEANED ACCORDING TO GOOD 2.
REVISION FOR CLASS 20 GREY IRON CASTINGS.
UNLESS NOTED OTHERWISE, CAST IRON SHALL CONFORM TO A.S.T.M. SPECIFICATIONS A48 LATEST 1.
3/
4"
PLAN
1/8"
7/16"
1/
2"
5"
10"
18 1/2"
18 3/8"
11/16"
1 3/8"
1/
2"
1/
8"
5/
16"
1/8"
20"
1 1/4"
2 1/2"
7/16"
4 1/4"
3/4"
5"1"
1/2" R
7"R
3/4"
1
1/
4"
9 7/
8"
4 1/4"
4 15/16"R
1/4"
3/4"R
3/
8"
2
1/
2"
2 7/
8"
2"
30"R1/2"
3/16"
3/8" 1/
8"
1 3/8"
1/2"
1/16"
METER BOX LID
5/16"
ORIG. DATE: OCT. 2004
DATE: OCT. 2011
SCALE: N.T.S.
DETAIL NO. WR-G_ME001
AND SHOULD BE REVIEWED THOROUGHLY.
THIS DETAIL WAS TAKEN FROM THE CITY OF ATLANTA'S WEBSITE. IT MAY HAVE BEEN MODIFIED
AND LAY OFF 1-21/64" C.C.
AT CENTER OF LID, STRADDLE C.L.
ALL RIBS EQUALLY SPACED. BEGIN
,
A.
G
A
56
81
74
81
ATNAL
T
S
NEG
R
USE
R
STANDARD DETAILS
ASSEMBLY
TYPICAL METER BOX
1/4"
1 3/4"
WA
TE
R ME
TE
R
METER BOX PLAN
4 3/4" x 2 1/2"
ATLANTA ONLY ALL OTHERS
END SLOT DIMENSIONS
5/16"x1/16"
BEVELED
OF ALL RIBS
SIDES AN ENS
METER BOX SECTION
Department of Public Works
City of Atlanta
1/8"
ORIG. DATE: NOV. 2004
DATE: OCT. 2011
SCALE: N.T.S.
STANDARD DETAILS
GUTTER REPAIRS
SIDEWALK, CURB AND
DETAIL NO. WR-G_PV004
AND SHOULD BE REVIEWED THOROUGHLY.
THIS DETAIL WAS TAKEN FROM THE CITY OF ATLANTA'S WEBSITE. IT MAY HAVE BEEN MODIFIED
EXISTING MATERIALS AS DIRECTED.
REPLACE SIDEWALKS, CURB AND GUTTER AND CURBING TO MATCH 2.
DETAILS ARE TYPICAL1.
NOTE:
"A"-"A" "B"-"B"
SERVICE LINE
A B
2%
1
2
A B
6' MAX
EXPANSION JOINTS
30'-0"
SCORED
JOINTS
TRENCH TO BE
COMPACTED TO
95% DENSITY
EXPANSION
JOINT
CONCRETE
SIDEWALK
EXPANSION
JOINT
CONCRETE
SIDEWALK
10x10 MESH
12"
4"R0.75
3'-0" TO 5'-0" VARIES 2'-0" 2'-0"
1'-6"ASPHALT
4" BITUMINOUS
MACADAM BASE
6"
1.5"
CONCRETE OR
GRANITE CURB
PAVEMENT
BASE
,
A.
G
A
56
81
74
81
ATNAL
T
S
NEG
R
USE
R
City of Atlanta REV.
CONSTRUCTION DETAILS
44-0009
I-20 EB @ CS 2776/MAYNARD TERRACE
REVISION DATES
12/17/2020
USER:USCW670696
GPLOT-V8
gplotborder-V8i-PO-COA.tbl
C:\Users\uscw670696\Desktop\CAD\0013333\700 CAD\740 Sheets\0013333_44-0009_Details.dgn
10:59:26 PM
GPLN10/23/2015
CHECKED:
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
DRAWING No.
Project No.
0013333
SUMMARY OF QUANTITIES
ITEM NO. ITEM DESCRIPTION UNIT QUANTITY
500-3200 CLASS B CONCRETE (FOR THRUST RESTRAINTS) CY 3.7
600-0001 FLOWABLE FILL CY 8.2
610-2370 REMOVE WATER MAIN, 8 IN LF 50
611-8010 ADJUST HYDRANT TO GRADE EA 1
611-8050 ADJUST SANITARY SEWER MANHOLE TO GRADE EA 2
611-8120 ADJUST WATER METER BOX TO GRADE EA 1
611-8140 ADJUST WATER VALVE BOX TO GRADE EA 1
670-0800 WATER METER EA 4
670-1060 WATER MAIN, 6 IN, RESTRAINED JOINT LF 70
670-1080 WATER MAIN, 8 IN, RESTRAINED JOINT LF 760
670-1600 CUT & PLUG EXISTING WATER MAIN EA 3
670-2060 GATE VALVE, 6 IN EA 1
670-2080 GATE VALVE, 8 IN EA 4
670-2700 ABANDONMENT OF WATER VALVE EA 1
670-4000 FIRE HYDRANT EA 1
670-5620 WATER SERVICE LINE, 3/4 IN LF 70
670-5010 WATER SERVICE LINE, 1 IN LF 85
670-9900 REMOVE EXIST WATER METER, INCL BOX EA 4
670-9920 REMOVE EXISTING FIRE HYDRANT EA 1
(INCIDENTAL ITEMS)
SUMMARY OF QUANTITIES
06-XXXX
I-20 EB @ CS 2776/MAYNARD TERRACE
REVISION DATES
12/17/2020
USER:USCW670696
GPLOT-V8
gplotborder-V8i-PO-COA.tbl
C:\Users\uscw670696\Desktop\CAD\0013333\700 CAD\740 Sheets\0013333_06-XXXX.dgn
11:04:46 PM
GPLN10/23/2015
CHECKED:
BACKCHECKED:
CORRECTED:
VERIFIED:
DATE:
DATE:
DATE:
DATE:
DRAWING No.
Project No.
0013333
Emergency Utility Response Information (EURI)
The purpose of Emergency Utility Response Plan (EURP) is to ensure that utility systems of the
project can be taken out of service in the event of damage, provide emergency contact
information, and to assist the Contractor in developing an Emergency Response Plan for the
project. This is particularly important to public safety where electrical, water, sanitary and
natural gas systems are involved. Thus, the Emergency Response plan should identify switches
and valves that control the flow of utility services that should be stopped when continued flow
would compromise public safety. The Emergency Response Plan is not meant to put others in
charge of these same switches and valves. It is meant to ensure that these switches and valves
have been checked for access and operation. For telecommunications systems, the EURP should
detail the procedure for initiating repair efforts in the shortest order. Provide this information
under Special Requirements.
Project Description/Permit Number: P.I. 0013333 I-20 EB to CS 2776/Maynard Terrace
Company Name: City of Atlanta - DWM
Type of Facility: Potable Water: 6-inch and 8-inch water mains and
appurtenances
(gas/water/sewer/electric/cable/telecommunications/ etc…)
• Emergency Contact Name: Joe Carpenter Phone Office: 404-546-1331
Cell: 678-414-9042 Email:
• Alternate Contact Name: Daniel Ephraim Phone Office: 404-546-3368
Cell: 678-382-4567 Email:
• Emergency Response Time: 2 hours
• Type of Material: Ductile Iron
• Number of existing valves within the project limits: 2
• Number of Emergency Response valves within the project limits (approximate location
details / Station Numbers based on the Project Utility Plans): N/A
• Number of switches within project limits (approximate location details / Station Numbers
based on the Project Utility Plans): N/A
• Date of last maintenance survey of valves, switches and pertinent devices: N/A
• Working condition of devices/Special Requirements: N/A
• In the case of non-functioning valves/switches within the project limits, provide the
approximate location details of the nearest valve / switch outside the project limits: N/A
Created: 2/05/2010 First Use: Revised:
NPDES UTILITY COMPLIANCE STATEMENT
Utility Owner Name: City of Atlanta Department of Watershed Management P.I. Number: 0013333
1. Check the appropriate box regarding applicability of the NPDES General Permit, No. GAR100002. If subject to coverage under GAR100002, attach a copy of the Notice of Intent signed by the Utility listed above. If not subject to coverage under GAR100002, provide a statement regarding permit coverage and use of best management practices consistent with the Manual for Erosion & Sediment Control in Georgia.
Yes (NOI attached*) – (*this copy is not proof of submittal to EPD and will not be considered as the copy on the construction
site).
No (not subject to NOI coverage; provide statement below). This project disturbs less than one (1) acre of the ground surface and is not subject to coverage under GAR100002. Best Management Practices (BMPs) will be established and implemented per the Manual for Erosion & Sediment Control in Georgia.
2. Insert a statement regarding the applicability of State Waters Buffer variances:
State Waters Buffer variances are not applicable for this project.
3. Check “Yes” if buffer variance is required or check “Not Applicable”.
Yes (executed variance is attached).
Not Applicable (buffer variance is not required).
4. This Compliance Statement should be completed by a representative possessing current design professional credentials as defined in the GAR100002 permit. If completed by a design professional, please insert the certification ID number. Acceptance of this Statement by the Department does not confer legitimacy and accuracy or in any way transfers liability for errors or omissions made by the preparer.
Printed Name: Samuel Broder Date: 03/9/2022
Signature: Title: Project Manager
Certification ID:
March 9, 2022 RE: P.I. 0013333_I-20 EB at CS 2776/Maynard Terrace in Fulton County
City of Atlanta (“City”) Georgia Utilities Permit Application – No Cost – Water Facilities To Whom It May Concern,
This letter is in support of attached Georgia Utilities Permit Application for the relocations and adjustments
of water facilities within the project limits of P.I. 0013333 – Maynard Terrace Roundabout. Proposed water
facilities relocation work includes the following: removal & replacement of one (1) fire hydrant, as well as
associated water mains, connections, and valves as shown on the Utility Relocation Plans dated July 23,
2021. Proposed water facilities relocation work includes the following: adjustment of one (1) fire hydrant,
and the adjustment of one (1) water meter box, the abandonment of one (1) water valve, and the adjustment
of one 1) water valve. Proposed water facilities relocation work also includes the following: installation of
one (1) water meter and box, installation of one (1) 6-inch gate valve, installation of four (4) 8-inch gate
valves, and the installation of one (1) fire hydrant. The relocations and adjustments are necessary to facilitate
the construction of proposed signal upgrades and pedestrian accommodations that will allow each
intersection in the project to meet ADA requirements. The existing water facilities in the project limits
conflict with the proposed work. Therefore, it will be necessary to relocate and adjust the water facilities
through conventional construction methods, as shown on the Utility Relocation Plans dated July 23, 2021.
The adjustments will be completed in accordance with the 2016 Georgia Department of Transportation
Utility Accommodations Policy and Standards. Adjustments will be performed through a GDOT-let contract
performed by a GDOT Contractor. There will be no cost to GDOT related to this portion of the work. The
City of Atlanta will assume the costs associated with the adjustments of water assets for this project.
If there are any questions or if any additional information is needed, please contact Daniel Ephraim of the
City of Atlanta by email at [email protected], or phone at (404) 546-3368.
Regards,
Sam Broder
Samuel Broder, PE Project Representative
City of Atlanta Department of Watershed Management
cc: Christopher Merzius, City of Atlanta DWM
Joseph Carpenter, City of Atlanta DWM
Attachments
1. Georgia Utilities Permitting Application
GENERAL PROVISIONS
IT IS EXPRESSLY STIPULATED THAT THIS PERMIT IS A LICENSE FOR PERMISSIVE USE ONLY, AND THE PLACING OF UTILITY FACILITIES UPON PUBLIC PROPERTY, PURSUANT TO THIS PERMIT, SHALL NOT OPERATE TO CREATE OR VEST ANY PROPERTY RIGHT IN THE HOLDER.
WHENEVER NECESSARY FOR THE CONSTRUCTION, REPAIR, IMPROVEMENT, MAINTENANCE, SAFE AND EFFECTIVE OPERATION, ALTERATION OR RELOCATION OF ALL OR ANY PORTION OF THE HIGHWAY, AS DETERMINED BY THE DEPARTMENT, ANY OR ALL OF SAID FACILITIES AND APPURTENANCES AUTHORIZED HEREUNDER SHALL BE IMMEDIATELY REMOVED FROM THE RIGHT-OF-WAY, OR RESET OR RELOCATED THEREON, AS REQUIRED BY THE CHIEF ENGINEER, AND AT THE SOLE EXPENSE OF THE UTILITY, UNLESS REIMBURSEMENT IS AUTHORIZED BY SEPARATE AGREEMENT. SHOULD THE UTILITY FAIL TO REMOVE OR RELOCATE ITS FACILITIES UPON DUE NOTICE FROM THE DEPARTMENT, THE UTILITY SHALL BE LIABLE FOR ANY EXTRAORDINARY COSTS OR DAMAGES INCURRED BY THE DEPARTMENT AS A RESULT THEREOF.
IF THE DEPARTMENT UNDERTAKES TO IMPROVE THIS HIGHWAY, IT SHALL BE THE RESPONSIBILITY OF THE UTILITY TO PLAN, WITH THE DEPARTMENT AND ITS CONTRACTOR, A SCHEDULE WHICH WILL CLEARLY SETS FORTH AT WHICH STAGE OF OPERATIONS THE UTILITY WILL BE REQUIRED TO PERFORM ANY ADJUSTMENT TO ITS FACILITIES NECESSARY TO ACCOMMODATE THE HIGHWAY IMPROVEMENTS.
DURING THE INITIAL INSTALLATION OR CONSTRUCTION OF FACILITIES AUTHORIZED BY THIS PERMIT, OR DURING ANY FUTURE REPAIR, REMOVAL OR RELOCATION THEREOF OR ANY MISCELLANEOUS OPERATIONS, THE UTILITY SHALL, AT ALL TIMES, MAINTAIN FLAGMEN, SIGNS, LIGHTS, FLARES, BARRICADES, AND OTHER SAFETY DEVICES IN ACCORDANCE WITH THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD), CURRENT EDITION, AND, AS MAY BE NECESSARY, TO PROPERLY PROTECT TRAFFIC UPON THE HIGHWAY AND TO WARN AND SAFEGUARD THE PUBLIC AGAINST INJURY OR DAMAGE.
IT IS EXPRESSLY PROVIDED THAT, WITH RESPECT TO ANY LIMITED ACCESS HIGHWAY, THE UTILITY SHALL NOT HAVE OR GAIN DIRECT ACCESS, EITHER INGRESS OR EGRESS, FROM THE MAIN TRAVELED WAY OF SAID HIGHWAY OR ITS ON OR OFF RAMPS TO ANY FACILITIES AUTHORIZED BY THE PERMIT EXCEPT UPON SPECIFIC APPROVAL BY
THE DEPARTMENT.
IT IS THE UTILITY’S RESPONSIBILITY TO VERIFY THE LIMITS OF RIGHT-OF-WAY FOR LOCATION OF THE UTILITY FACILITIES AUTHORIZED HEREBY.
NO INHERENT OR RETAINED RIGHT OR PRIVILEGE OF ANY ABUTTING PROPERTY OWNER IS AFFECTED BY THIS PERMIT NOR IS THE DEPARTMENT RESPONSIBLE FOR ANY CLAIM WHICH MAY DEVELOP BETWEEN THE UTILITY AND ANY PROPERTY OWNER CONCERNING USE OF THE RIGHT OF WAY. THE UTILITY IS RESPONSIBLE FOR MAINTAINING REASONABLE ACCESS TO PRIVATE DRIVEWAYS DURING INSTALLATION OF ITS FACILITIES AND FOR RESTORATION OF DRIVEWAYS TO THE PROPERTY OWNER’S SATISFACTION.
APPROVAL OF THIS PERMIT DOES NOT CONSTITUTE APPROVAL OF DESIGN OR CONSTRUCTION DETAILS FOR THE PROPOSED UTILITY FACILITIES. THE UTILITY IS RESPONSIBLE FOR COMPLIANCE WITH ALL APPLICABLE GOVERNMENTAL CODES AND REGULATIONS.
THE UTILITY SHALL GIVE THE DEPARTMENT A MINIMUM OF 24 HOURS NOTICE PRIOR TO BEGINNING ANY WORK UNDER THIS PERMIT.
THIS PERMIT SHALL BE VOID UNLESS WORK HEREUNDER IS BEGUN WITHIN TWELVE (12) MONTHS OF THE DATE OF ITS APPROVAL.
THE PROVISIONS OF THIS PERMIT ARE REGULATORY AND NOT CONTRACTUAL. NO INTEREST OR RIGHT OF A UTILITY GRANTED BY THIS PERMIT MAY BE TRANSFERRED TO ANOTHER EXCEPT BY WRITTEN CONSENT OF THE DEPARTMENT. THIS PERMIT MAY BE REVOKED AT THE PLEASURE OF THE DEPARTMENT UPON THIRTY (30) DAYS WRITTEN NOTICE TO THE UTILITY.