INSPIRED LISTENING - Topakustik®
-
Upload
khangminh22 -
Category
Documents
-
view
4 -
download
0
Transcript of INSPIRED LISTENING - Topakustik®
BEAUTY MEETS
PERFORMANCE
We are proud to present our revised Topakustik product range. Our products can still be configured to satisfy all your requirements for function, form and aesthetic, so you can sustainably improve your or your customers’ quality of life by appealing to their eyes and their ears.
This brochure features classic products, such as the widely used TOPAKUSTIK Type 14/2M, but if you really want to do your own thing and realize your own ideas, please don’t hesitate to contact us. Our motivated and experienced team of specialists from planning, technology and production see themselves as your solutions partner and are ready to rise to any challenge.
Together we can make your interiors sound more beautiful!
Marcel M. Müller, CEO
HQ “La Française”, Boulevard Raspail, Paris Architect: Franklin Azzi, Paris – Photo: Luc Boegly, Paris Product: TOPPERFO Micro 2/2/0.5, Oak veneered
This ceiling, consisting entirely of triangular shapes, adds that special extra touch to the reception area at the headquarters of finance group “La Française” on Boulevard Raspail in Paris. Over 30 different triangles were first produced in our factory and then the readytoinstall elements were quickly and easily mounted on site.
3
TECHNICAL INFORMATION
THE REF INED ACOUST IC SYSTEM
Ava i l a b l e i n p l a n k s w i t h a t o ngue a nd g r oo v e c onnec t i o n ( p l a n k w id t h = 128 mm*) f o r j o i n t f r e e su r f a c e appea r an c e o r i n p ane ls ( p ane l w i d t h = 300 – 1200 mm) f o r r emovab l e o r f i x ed c e i l i n gs, wa l l s o r c ab i n e t f r o n t s .
PERFORAT ION AS REQU IRED
A w ide range o f pe r f o ra t i ons f o r wa l l and ce i l i ng f i n i shes . Conven t i ona l MPer fo ra t i on , d i sc re te TPer f o ra t i on o r m ic ro per f o ra t i ons (C l ou + M ic ro ) . Ava i l ab l e i n pane l s and p l anks .
The information in boxes is very important and should be read carefully !
WIPO Geneva CHArchitect: Behnisch Architekten, Stuttgart DE – Photo: David Matthiessen, Stuttgart DE Product: TOPPERFO Micro 2/2/0.5, Silver Fir veneered
Panels
Planks
Rear Perforation
Grooving
Rear Perforation
Face
Perforation
Panels
Planks
* 1 IN C H = 25.4 m m e .q . 128 m m = 5.0 4”
NEW!= new P r oduc t s
CONTENTS
4 / 5
6 / 7
8 / 9
1 0 / 1 1
1 4
1 5
1 6 / 1 7
1 8
1 9
2 0 / 2 1
2 2 / 2 3
2 4 / 2 5
2 6 / 2 7
3 0 / 3 1
3 2 / 3 3
3 4 / 3 5
3 6
3 7
3 8
3 9
4 0
4 1
4 4
4 5
4 6
4 7
4 8
4 9
TE
CH
NIC
B A S I C S
N A R R O W G R O O V E S
M E D I U M S I Z E D G R O O V E S
W I D E G R O O V E S
T O PA K U S T I K R
T O PA K U S T I K S p e c i a l g r o o v e s
T O PA K U S T I K L i n e
T O PA K U S T I K A R I A P l u s
T O PA K U S T I K A R I A P u r e
C O R E M AT E R I A L
S U R FA C E S E C O
E D G E S + D E TA I L S
M O U N T I N G
BAS ICS T O P P E R F O M i c r o
T O P P E R F O M i c r o S p e c i a l
T O P P E R F O C l o u
T O P P E R F O T
T O P P E R F O M
T O P P E R F O G r a p h i c
T O P P E R F O S p e c i a l
S I X T Y – S Y S T E M ( 2 x 2 PA N E L S )
C A B I N E T S F R O N T S + D O O R S
S H A P E S
G Y M N A S I A
S W I M M I N G P O O L S
N H Q U A L I T Y + S E R V I C E
C O N TA C T I N F O R M AT I O N
NEW!
NEW!
NEW!
NEW!
NEW!
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000 Hz
a s
a w Euro NRC
0.80 M B 0.88
0.75 M C 0.87
55
mm 215
mm
321
321
4
4
128 mm
4 5
The refined acoustic system for wall and ceiling finishes. Many different groove patterns are available. Narrow spaced grooves appear as a textured surface (6/2, 8/3, 9/2) – wider spaced grooves can be seen individually by the eyes (12/4, 13/3, 14/2, 19/2, 28/ 4). Thanks to the rear perforation pattern, the core panel remains structurally intact allowing for cutouts (programmed or field performed) to address penetrations required for lighting, HVAC and sprinkler systems.
T-Perforation: For absorption in the low to medium frequency range. The high absorption in the lowfrequency range is based on the combination of small holes on the visible side and larger holes on the rear.
M-Perforation: For absorption in the medium to high frequency range. TOPAKUSTIK products with MPerforation are suited for applications in which the reverberation time is to be lowered across a broad frequency band.
Reflectors: TOPAKUSTIK products can also be used as reflectors by eliminating the perforations on the rear surface. The absorption figures are then equivalent to those of a standard reflecting panel.
4 air cavity
3 Fibreglass 30 mm (40 – 60 kg / m3;
2.5 – 3.75 pcf)
2 Acoustic fleece SP 60 laminated
1 TOPAKUSTIK element in 16 mm MDF
Measured according to ISO 354:
THE ACOUSTIC SYSTEM
All TOPAKUSTIK types are available with M and T perforations on the rear. This makes it possible for acousticians to match the TOPAKUSTIK surface treatment with the required absorption. The absorption coefficients stated in this brochure were measured according to the ISO 354 standard and are set up as described above. Additional absorption coefficients with other cavity depths and other porous materials in the air cavity (e.g. only fleece, melamine resin foam, etc.) are listed in the TOPAKUSTIK / TOPPERFO sound absorption document.
The sound absorption of our products is measured in a reverberation room in accordance with DIN ISO 354:1985. This provides the as (alpha) values either listed in tabular form or plotted on a chart. You can find such charts in the descriptions of the individual products.The aw value given in the table is the weighted sound absorption level that is calculated using a standardized method.The classification into Euroclasses A, B, C, D and E is calculated and derived from the aw value (A = highest absorption capacity)The NRC (noise reduction coefficient) is the value specified according to the US standard ASTM C423. Behind each aw value are the letters L, M and/or H to indicate if the sound absorption of the product is greater than 0.25 in a specific frequency range. L is for low or 250 Hz, M is for mid or 500 or 1000 Hz, and H is for high or 2000 or 4000 Hz.
Please note: Walls finished with lighter veneers (maple, birch) or lighter paint (white) can have a visually disturbing effect (flickeringMoiré Pattern) from the light to dark contrast from the face surface to the grooves. In these areas we recommend using the TOPAKUSTIK designs with 2 mm wide groove e.g. type 9/2 or 14/2 or 19/2 and / or using darker veneers or darker paint colours to minimize this effect.
Example:
DIMENSIONS AND MATERIALS
PlanksThanks to the precise tongue and groove connection, planks result in an attractive surface with a jointfree appearance, because the connecting joint matches the dimension of the grooves. The planks permit simple and flexible assembly. They can be installed by stapling to a timber batten or clamping to a Tbar with TOPAKUSTIK clips. (Assembly p. 26)
not fire rated Ds2,d0 / CH RF 3 fire retardant Bs1,d0 / CH RF 2 RESAP® Core non-flammable
Paint
16 mm
Wood Veneer
17 mm
Melamine
16 mm
Paint
16 mm
Wood Veneer
17 mm
Melamine
16 mm
Paint
16 mm
Wood Veneer
17 mm
Standard = Matched to MDF Core Sizes
2780 × 128 2780 × 128 2780 × 128 2780 × 128 2780 × 128 2780 × 128 2540 × 128 2540 × 128
3640 × 128 3080 × 128 3080 × 128
4080 × 128 4080 × 128 4080 × 128 4080 × 128 4080 × 128 4080 × 128
custom lengths are also available
not fire rated Ds2,d0 / CH RF 3 fire retardant Bs1,d0 / CH RF 2 RESAP® Core non-flammable
Paint
16 mm
Wood Veneer
17 mm
Melamine
16 mm
Paint
16 mm
Wood Veneer
17 mm
Melamine
16 mm
Paint
16 mm
Wood Veneer
17 mm
Standard = Matched to MDF Core Sizes
2040 × 992 / 640 2040 × 992 / 640 2040 × 992/640 2040 × 992/640 2040 × 992/640 2040 × 992/640 1540 × 608 1540 × 608
2780 × 992 / 640 2780 × 992 / 640 2780 × 992/640 2780 × 992/640 2780 × 992/640 2780 × 992/640 2540 × 608 2540 × 608
3640 × 608 3080 × 608 3080 × 608
4080 × 640 4080 × 640 4080 × 640 4080 × 640 4080 × 640 4080 × 640
custom lengths are also available – Max width depends on raw panel, approx. 1200–1250 mm
Panels Panels are used for removable or fixed ceilings and walls with visible joints. Panels can be provided with a number of different edges (p. 24) and are alsosuited for cabinet fronts and room dividers.
Interrupted grooves:With panels, the grooves can be interrupted. The distance can be chosen as required.
Fire category – more information page 20 / 21
page 22 / 23
Date 2022 – please check the current dimensions on www.topakustik.ch
depending wood depending wood
depending wood depending wood
300 – ca.1200 mm
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000
a w Euro NRC
0.85 M B 0.90
0.80 M B 0.85
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000
a s
86 2 10.66*8.7 2
a w Euro NRC
0.80 B 0.80
0.75 C 0.80
a sHz
125
250
500
1000
2000
4000
a w Euro NRC
0.40 LM D 0.55
0.40 LM D 0.60
Hz Hz
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000
a s
125
250
500
1000
2000
4000
a w Euro NRC
0.85 L B 0.90
0.8 M B 0.85
a w Euro NRC
1.00 A 1.00
0.7 MH C 0.85
10.66*7.7 3
1.4.2
Abhängehöhe 200 mmAbhängehöhe 56 mm
9.50%Seite 7
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
Seite 7 - 1-4-2_TOPAK_8-3-M_9.5%_200-56.xls 05.07.2016
1.4.1
Abhängehöhe 200 mmAbhängehöhe 56 mm
19%Seite 7
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
Seite 7 - 1-4-1_TOPAK_8-3-M_19%_200-56.xls 30.06.2016
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
321
6 7
NARROW GROOV INGCENTER-TO-CENTER DISTANCE = 8 mm or 10.66 mm
This grooving is less «visible» as the interaction of light and shadow occurs regularly due to the close spacing of the grooves, thus creating a 2dimensional effect. The narrow grooves require perfect assembly, as even the smallest differences in the surface are visible.
Type 6 /2 M or T
See page 5 for dimensions and materialsSee page 22 / 23 for surfaces
TOTAL THICKNESS
≈ 215 mm
≈ 55 mm
More information Page 4
6/2 M7 % 6/2 T
1 LVM, Münster DE – Architect: HPP Düsseldorf, DE – Photo: HGEsch / Hennef, Blankenberg DE 2 Pilatus Businesscenter, CH 3 AVM Computersysteme, Berlin DE – Architect: Trucks Architekten, Berlin DE
9/2 M6 %8/3 M9.5 % 8/3 M19 %
Type 8 /3 M Type 9 /2 M
Type 8/3 + 9/2:please respect 10.66 mm for planning
Hz
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000
a sHz
125
250
500
1000
2000
4000 12
5
250
500
1000
2000
4000
a w Euro NRC
0.90 A 0.90
0.85 B 0.85
a w Euro NRC
0.65 L C 0.70
0.60 LM C 0.75
a w Euro NRC
0.35 LM D 0.55
0.35 LM D 0.60
a w Euro NRC
0.75 L C 0.75
0.65 LM C 0.80
1.21
0.80.60.40.2
0
125
250
500
1000
2000
400012
5
250
500
1000
2000
4000 Hz
1614 2 1612 4
a w Euro NRC
0.80 M B 0.85
0.80 B 0.90
a s
125
250
500
1000
2000
4000
a w Euro NRC
0.75 L C 0.80
0.65 LM C 0.75
1613 3
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000
a w Euro NRC
0.90 A 0.90
0.85 B 0.85
a s
Seite 8 - linke Grafik -7%
rote schrift 0,85 B 0,86
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
Seite 8 - 3-9-3_TOPAK_14-2-M_7%_216-56.xls 23.08.2016
3.12.1
Abhängehöhe 216 mmAbhängehöhe 56 mm
3.50%
Seite 8
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
Seite 8 - 3-12-1_TOPAK_14-2-M_3.5%_216-56.xls 05.07.2016
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
14/2 M3.5 % 13/3 M12 % 13/3 M6 % 13/3 T 12/4 M15 % 12/4 M7.5 %14/2 M7 %
54 6
8 9
MEDIUM-S IZED GROOV INGCENTER-TO-CENTER DISTANCE = 16 mm
The most popular TOPAKUSTIK types. High sound absorption combined with easy assembly. The grooving is visible even from a long distance.
See page 5 for dimensions and materialsSee page 22 / 23 for surfaces
Type 14 /2 M Type 13 /3 M or T
TOTAL THICKNESS
≈ 215 mm
≈ 55 mm
More information Page 4
Type 12 /4 M
4 AWZ, Kleindöttingen CH – Architect: Birchmeier Uhlmann Architekten, Zürich ZH – Photo: Sibylle Kathriner Fotografie, Stans CH 5 Alfred Wegener Institut, Bremerhaven DE – Architect: Westphal Architekten, Bremen DE – Photo: Anke Müllerklein, Hamburg DE 6 Hôpital Leon Bérard, Lyon
TOTAL THICKNESS
≈ 245 mm
≈ 95 mm
More information Page 4
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000
a s
a w Euro NRC
0.65 L C 0.75
0.60 LM C 0.75
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000
a w Euro NRC
0.85 B 0.80
0.80 B 0.85
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000
a s
21.33*19 2 3228 4
a w Euro NRC
0.55 LM D 0.80
0.55 M D 0.70
a s
0
0.2
0.4
0.6
0.8
1
1.2
0
0.2
0.4
0.6
0.8
1
1.2
0
0.2
0.4
0.6
0.8
1
1.2
0
0.2
0.4
0.6
0.8
1
1.2
3229 3
125
250
500
1000
2000
4000 12
5
250
500
1000
2000
4000 Hz
a w Euro NRC
0.5 LM D 0.65
0.5 LM D 0.70
a w Euro NRC
0.25 LM E 0.40
0.25 LM E 0.50
4.7.1
Abhängehöhe 216 mmAbhängehöhe 56 mm
Seite 10
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
Seite 10 - 4-7-1_TOPAK_19-2-M_6%_216-56.xls 05.07.2016
4.8.3
Abhängehöhe 216 mmAbhängehöhe 76 mm
Seite 11
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
Seite 11 - 4-8-3_TOPAK_28-4-M_4.7%_216-76.xls 05.07.2016
30 2
125
250
500
1000
2000
4000
a w Euro NRC
0.55 LM D 0.70
0.50 LM D 0.70
Hz
125
250
500
1000
2000
4000
a w Euro NRC
0.80 B 0.85
0.80 B 0.85
Hz
18 3
19/2 M6 % 29/3 M6 % 28/4 M7.5 % 28/4 M3.75 % 28/4 T30/2 M3.5 %18/3 M8.5 %
97 8
10 11
WIDE GROOV INGCENTER-TO-CENTER DISTANCE = 21.3 or 32 mm
These grooves are the ideal solution for standard absorption requirements. As with all centretocentre distances, the wide grooving comes with 2 mm, 3 mm and 4 mm groove, as laid out in this and page 11.
See page 5 for dimensions and materialsSee page 22 / 23 for surfaces
Type 19 /2 M & 18 /3 M Type 29/3 M & 30 /2 M Type 28 /4 M or T
TOTAL THICKNESS
≈ 215 mm
≈ 55 mm
More information Page 4
Type 19/2 + 18/3:please respect 21.33 mm* for planning
7 Landratsamt Ostallgäu, Marktoberdorf DE – Architect: Stadtmüller.Burkhardt.Graf Architekten GbR, Kaufbeuren DE – Photo: Klein & Schneider GbR, Mindelheim DE 8 University of Sydney AU – Architect: Kannfinch, Sydney AU – Photo: Euroline Pty Ltd., Auburn AU 9 Wheaton High School, USA – Architect : Grimm + Parkins Architects, USA – Photo: Kevin Burns, USA
NEW!
COMPOSING A
MASTERP IECE
Should you require each panel to be a different shape or a standard solution is preferred – we can manufacture both. For products that are easier to use such as our TOPAKUSTIK planks, you can decide how the surface will look. You can choose any RAL/NCS colour, any commercially available wood veneer or perhaps you prefer a decorative melamine resin finish, with many being available. Whatever your choice, we’ll be delighted to play our part in composing your «MASTERPIECE».
Aviva HQ, St. Helens Tower, London GBArchitect: TTSP Archi. + Design, London GB – Photo: Nick Guttridge, London GBProduct: TOPAKUSTIK Planks 14/2 M-7 %
This auditorium is naturally dominated by the gigantic screen that extends across its entire front. But all the other walls are covered with TOPAKUSTIK planks to ensure that the acoustics are perfect! Another benefit: the warmth emanated by the genuine wood veneer provides a pleasant counterbalance to the otherwise cool interior.
10.668.66 2
16
Lamellen Typ R 2
128
4
Paneelen Typ R 3
5
336
592
28
30
4
2
16 (
17)
16 (
17)
+19
(20
)
29 3 1
1
1
3
2
4
332/620/908/1196
= RL3
= RL4
= RL2
128
128
128
A
A
A
A
B
B
A
A
C
A
B
B
Solo
Duo
Trio
592
28
30
4
2
29 3 1
1
1
3
2
4= RP3
= RP4
= RP2
R4 M -9,4 % a w Euro NRC
226 mm 0.80 B 0.80
56 mm 0.80 B 0.85
R3 M -7,4 % a w Euro NRC
226 mm 0.80 B 0.80
56 mm 0.75 C 0.80
R2 M -4,5 % a w Euro NRC
216 mm 0.70 L C 0.75
56 mm 0.65 M C 0.75
121110
14 15
TOPAKUST IK-R
Type R has an irregular grooving pattern that repeats itself systemically every 128 mm. Two (Type Duo) or even three (Type Trio) differently grooved planks increase the irregularity, especially when its assembly happens randomly. On panels, the grooving repeats itself only every 592 mm, which would not be noticed.
R-P lanks R-Pane ls
NEW!
10 EPFL, Lausanne CH – Architecte: Richter-Dahl Rocha & Associés architectes SA, Lausanne CH – Photo: EPFL, Lausanne 11 Family Lodge + Spa, Melchsee-Frutt CH – Architect: Architekturwerk AG, Sarnen CH – Photo: Sibylle Kathriner Fotografie, Stans CH 12 Theater Agora, Lelystad NL – Architect: UNStudio, Amsterdam NL
SPEC IAL GROOVES
Would you like the grooving to be something special? How about our type HR 9/2 M with its semicircular grooves? Many more variations are possible: for instance, the distance between the grooves can be widened to 62 or 96 mm. Absorption values are available.
HR 9 /2 M
Surface: (only paint)
Fire category: Bs1,d0 + Ds2,d0
Planks: 3800 × 128 mm2600 × 128 mm
HR 9/2 M a w Euro NRC
215 mm 0.75 L B 0.80
55 mm 0.75 M C 0.85
61/3 M a w Euro NRC
226 mm 0.50 L D 0.50
66 mm 0.45 L D 0.50
60/4 M a w Euro NRC
226 mm 0.45 L D 0.55
66 mm 0.40 LM D 0.55
93/3 M a w Euro NRC
226 mm 0.35 L D 0.40
66 mm 0.35 L D 0.40
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
2/2/0.5
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
1.21
0.80.60.40.2
0a s
a w Euro NRC
0.60 (LM) C 0.75
0.60 (LM) C 0.80
a w Euro NRC
0.70 (L) C 0.80
0.70 (LM) C 0.85
a w Euro NRC
0.50 (LM) D 0.70
0.50 (LM) D 0.75
a w Euro NRC
0.70 (L) C 0.80
0.65 (LM) C 0.85
a w Euro NRC
0.75 (L) C 0.85
0.75 (M) C 0.90
a w Euro NRC
0.75 C 0.72
0.75 C 0.70
125
250
500
1000
2000
4000 Hz
a w Euro NRC
0.80 L B 0.95
0.75 LM C 0.95
125
250
500
1000
2000
4000
1.21
0.80.60.40.2
0a sHz
16 17
SURFACES Wood Veneer all types of wood veneer
(light veneers must be sampled)
Paint all except white and very light colours
(after consultation)
Melamine our ecoCollection 2.0 (only with MDF)
HPL coating on request
CORE MATER IAL– MDF 16 mm standard Ds2,d0 and
fire retardant Bs1,d0– RESAP® 16 mm (without melamine)– 3layer White Fir 16 mm
FORMATS– max. 4000 × 1280 mm
Panel dimensions are dependant on the repeated design in horizontal and vertical direction, which are assigned to each of the different designs.
Microperforation can be added to the complete surface of each of the 16 patterns. This increases the sound absorption values to those for our TOPPERFO Micro.
10 more designs in our flyer or on the homepage
CREATE YOUR OWN DESIGNIf you can’t find the right one, you can easily create your own! Send us your DXF file – we will be happy to check it out! Soon you’ll have your very own soundabsorbing wall or ceiling cladding.
TOTAL THICKNESS
ca. 226 mm
ca. 66 mm
MW 40 mm
TOPAKUST IK L ine
SOUND ABSORPT ION NEWLY DES IGNED– A completely new concept giving ornamental designs instead of perforations or
grooving– Virtually limitless individualisation through almost any design on nearly any surface
START ING COLLECT ION FOR 2022 We have chosen 16 different pattern (or designs) for our 2022 starting collection. On our website, you can find these designs in the four surfaces oak, white, grey and beige for convenient comparison – each surface gives the pattern a different finish. We are continuously adding new designs to our collection.
EXCELLENT PRODUCT DES IGN The Red Dot Design Award is one of the world’s largest design competitions. The products submitted are evaluated and awarded by a renowned jury of around 50 interna
tional experts. TOPAKUSTIK Line is the winner of the highest distinction in the competition, the «Best of the Best 2021».Statement by the Jury: TOPAKUSTIK has emerged with an entirely new aesthetic for soundabsorbing wall and ceiling finishes. The idea of using diverse graphic ornaments to aestheticise this area opens up ample freedom for individualisation in interior
design. The underlying concept is impressive in its logic as well as its highquality implementation. It removes the anonymous appearance of acoustic panels by introducing visually enticing qualities.
TOPAKUST IK L INE PLUS
Foto
s: P
rodu
ktio
n TO
PAKU
STIK
AG
L INE 2112Rep. Pattern w = 58 mm
h = 58 mm
L INE 2110Rep. Pattern w = 236.68 mm
h = 236.68 mm
L INE 2111Rep. Pattern w = 50 mm
h = 20 mm
L INE 2121Rep. Pattern w = 140 mm
h = 192 mm
L INE 2115Rep. Pattern w = 202.50 mm
h = 116.913 mm
L INE 2113Rep. Pattern w = 16 mm
h = 16 mm
2/2/0.5
h
w
h
h h
hh
w
w w
NEW!
Topakustik AG
Obseestrasse 11, 6078 Lungern, (+41) 41 679 73 73, [email protected], www.topakustik.chA+ und FSC Produkte sind gekennzeichnet / A+ and FSC products are marked /
Produits A+ et FSC sur demande / Prodotti A+ e FSC sono contrassegnati
SURFACES
Wood Veneer
all types of wood veneer
(light veneers must be sampled)
Paint all except white and very light colours
(after consultation)
Melamine
our eco-Collection 2.0 (only with MDF)
HPL coating on request
FORMATS
– max. 4000 × 1280 mm
Panel dimensions are dependant on the repeated design in
horizontal and vertical direction, which are assigned to each
of the 16 different designs.
NEW INNOVATION BY THE COMPANY YOU TRUST
TOPAKUSTIK® Line has been developed by Topakustik AG and manu-
factured by the same company in the heart of Switzerland.
Founded in 1991, Topakustik AG have a broad portfolio of products
with extensive experience and outstanding references worldwide,
in the field of acoustic wall and ceiling cladding manufactured from
timber materials. With our TOPAKUSTIK® Line, you can choose a
new product from a leading company.
TOPAKUSTIK® Line 2115
Rep. Pattern w = 202.50 mm
h = 116.913 mm
TOPAKUSTIK® Line 2113
Rep. Pattern w = 16 mm
h = 16 mm
Euro NRC
0.75 (L) C 0.85
0.75 (M) C 0.900.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
1.21
0.80.60.40.2
0 Hz
125
250
500
1000
2000
4000
TOPAKUSTIK® Line 2124
Rep. Pattern w = 120.5 mm
h = 147.0 mm
TOPAKUSTIK® Line 2120
Rep. Pattern w = 128 mm
h = 136 mm
Euro NRC
0.70 (L) C 0.80
0.70 (LM) C 0.85
Euro NRC
0.65 (L) C 0.61
0.65 (LM) C 0.60
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
1.21
0.80.60.40.2
0 Hz
125
250
500
1000
2000
4000
TOPAKUSTIK® Line 2119
Rep. Pattern w = 96 mm
h = 96 mm
TOPAKUSTIK® Line 2114
Rep. Pattern w = 128 mm
h = 128 mm
1.21
0.80.60.40.2
0 Hz
125
250
500
1000
2000
4000
5.12.3
15.20%
Abhängehöhe 200 mm
Abhängehöhe 60 mm
Seite 39
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
Seite 39 - 5-12-3_TOPP_M-Graphic-16-16-8_200-60.xls
05.07.2016
TOPAKUSTIK® Line
Sound Absorption Newly Designed
– A completely new concept giving ornamental
designs instead of perforations or grooving
– Virtually limitless individualisation through almost
any design on nearly any surface
SAMPLES A4:
Euro
pean
Oak
Am
eric
an C
herr
y
Oak
M32
80 N
TL
Map
le M
2106
SM
A
Whi
te B
3002
LP
RAL/
NC
S yo
ur c
hoic
e
RAL
beig
e 10
15
RAL
grey
700
4
RAL
gree
n 15
0 80
10
Am
eric
an W
alnu
t
Am
eric
an C
herr
y
veneered Ecolacquered veneered
17 mm 16 mm3–4 mm
2110 5 5 5 5 5 10 2
2111 5 5 5 5 5 102
2112 5 5 5 5 5 102
2113 5 5 5 5 5 10
2114 5 5 5 5 5 10 2
2115 5 5 5 5 5 10 2
2116 5 5 5 5 5 10 2
2117 5 5 5 5 5 10 2
2118 5 5 5 5 5 10 2
2119 5 5 5 5 5 10 2
2120 5 5 5 5 5 10 2
2121 5 5 5 5 5 102
2122 5 5 5 5 5 102
2123 5 5 5 5 5 102
2124 5 5 5 5 5 102
2125 10 10 10 10 10 10
within 2 working days ex works
within 5 working days ex works
within 10 working days ex works
Other surfaces on request.
1:4
1:4
1:8
1:4
1:4
1:8
CORE MATERIAL
– MDF 16 mm standard D-s2,d0 and
fire retardant B-s1,d0
– RESAP® 16 mm (without melamine)
– 3-layer White Fir 16 mm
hh
hh
h
h
w
w
w
w
w
NH_EN_Prospekt_TOPAKUSTIK Line_6seitig.indd 1
NH_EN_Prospekt_TOPAKUSTIK Line_6seitig.indd 1
22.12.21 12:1222.12.21 12:12
1413 15
+
18 19+
White Fir, finger – jointedpicture shows 65 x 15 cm Spruce Hardwood – picture shows 65 x 15 cm
ARIA-PLUS The perforation is barely visible thanks to the deep grooving and the black MDF board. The grooves create the effect of individual bars. ARIAPlus is available in knotty spruce or fingerjointed silver fir.
Size of core Planks
Spruce Hardwood4080 x 2050 x 20 mm ideal = 4080 x 128 x 20 mm
White Firfingerjointed
TOPAKUSTIK 12/4 MARIAPlus
TOPAKUSTIK 28/4 MARIAPlus
TOPAKUSTIK RL4 MARIAPlus
Lam
e
Pane
ls* Total thickness ≈ 215 mm Total thickness ≈ 55 mm
TOPAKUSTIK alpha w Euro NRC alpha w Euro NRC
12/4 M 15.0 % X 0.80 B 0.90 0.80 M B 0.85
28/4 M 7.5 % X 0.55 LM D 0.80 0.55 M D 0.70
RL3 M 7.4 % X 0.80 LM B 0.80 0.75 C 0.80
RL4 M 9.4 % X 0.80 B 0.80 0.80 B 0.85
Sound absorption data acc. to ISO 354 with acoustic fleece and Mineral wool 30 mm (60 kg/m3)
*Panels can only be produced for absolutely symmetrical products (stability)
13 Living room, Gonten CH – Architect and Photo: Roland Koch Innenarchitektur, Gonten CH 14 Pan Zentrum, Berlin DE – Architect: Parmakerli-Fountis Gesellschaft von Architekten mbH, Kleinmachnow DE – Photo: Allard van der Hoek, Amsterdam NL 15 Gotthard Autobahn Raststätte, Erstfeld CH – Architect: architektur lischer partner ag, Luzern – Photo: Roger Frei, Zürich
ARIA-PURE ARIAPure means silver fir through and through! We have the fingerjointed 3layer silver fir plywood in stock in two 16 mmthick formats.
Size of core Planks Panels
White Firfingerjointed4080 x 2050 mm ideal = 4080 x 128 mm ideal = 2020 x 640 mm
5000 x 2050 mm ideal = 2480 x 128 mm ideal = 2490 x 640 mm
TOPAKUSTIK RL3 MARIAPure
TOPPERFOM 16/16/6ARIAPure
TOPPERFOMicroARIAPure
Plan
ks
Pane
ls* Total thickness ≈ 215 mm Total thickness ≈ 55 mm
alpha w Euro NRC alpha w Euro NRC
TOPAKUSTIK
12/4 M 15.0 % X 0.80 B 0.90 0.80 M B 0.85
28/4 M 7.5 % X 0.55 LM D 0.80 0.55 M D 0.70
RL3 M 7.4 % X 0.80 LM B 0.80 0.75 C 0.80
RL4 M 9.4 % X 0.80 B 0.80 0.80 B 0.85
13.5/2.5 M 9.5 % X 0.90 A 0.90 0.85 B 0.85
18.5/2.5 M 3D 7.3 % X 0.80 B 0.85 0.75 M C 0.80
TOPPERFO
Micro 2/2/0.5 X 0.60 LM C 0.75 0.60 LM C 0.80
Micro 1.8/1.8/0.5 X 0.65 L C 0.80 0.65 LM C 0.85
16/16/6 11.0 % X 0.50 LM D 0.80 0.50 M D 0.75
16/16/8 19.6 % X 0.75 LM C 0.90 0.70 M C 0.80
16/16/10 31.0 % X 0.95 A 0.95 0.90 A 0.90
Sound absorption data acc. to ISO 354 with acoustic fleece and Mineral wool 30 mm (60 kg/m3)
Type 18.5/2.5 M with 3DSurface
➡➡
*Panels can only be produced for absolutely symmetrical products (stability)
NEW!
1
20 21
FIRE STABILITY ACCORDING TO EUROCLASS EN 13501-1
TOPAKUSTIK and TOPPERFO have successfully passed extensive tests in accordance with Euroclass EN 135011 and are classified as follows in the flameretardant specification: B-s1,dO
MEDIUM DENSITY F IBREBOARD (MDF)
TOPAKUSTIK and TOPPERFO products are manufactured from medium density fibreboard (MDF) as a standard. Thanks to the homogeneous structure, MDF is well suited for this application. MDF panels are produced from soft and hard wood fibers with added binding agents. Only panels meeting the international emission values E1 are processed. Panels are also avaialble in No added Formaldehyde and FSC certified upon request.
SPECIAL
CORE PANELS
TOPAKUSTIK and TOPPERFO can also be manufactured from other standard core panels.These can be broken down according to requirements with regard to– Behaviour in fire– Appearance, e.g. special surface or panel design– Special properties with regard to stability or moisture
RESAP® is a nonflammable panel (EN A1s1, d0 / DIN A1 / CH RF 1) made from natural gypsum and recycled cellulose fibres.
Core Materialdesignation
Firecategory DIN (CH)
Suitable for humid rooms
Basic sizes of core materials
Maximum expansion due to humidity increase for 1000 mm length in air conditioning
RESAP® A1 (RF 1)EN A1 – s1,d0
– + + –3100 × 12602560 × 1260
0.4 mm / 1 m = 0.4 %
3layer ARIA B2 (RF 3) ~ – ~ – page 18 / 19
Cement A2 (RF 1) + – & – 2600 / 3100 × 1250 0.8 mm / 1 m = 0.8 %
Particle board B2 (RF 3) – & & & DIV 0.8 mm / 1 m = 0.8 %
Flakeboard OSB B2 (RF 3) ~ – & – DIV 0.8 mm / 1 m = 0.8 %
Forex B1 (RF 2) + – & – 3050 × 1220
Plywood B2 (RF 3) ~ + & – DIV 0.8 mm / 1 m = 0.8 %
Legend:
– unsuited
+ well suited
& upon request
~ conditionally suited, take
differences in colour in
untreated panels into account
DIV various further formats,
please inquire.
Painted panels: homogenous design – surface and edges can be finished for seamless transition.The RESAPPlus version is recommended for a largely nonporous coat of paint.
Veneered panels:The lightbrown/beige colouring of the panel is visible in the grooves or perforations and in combination with oak, beech or light veneers gives a highquality appearance.
Explanations:
Wood veneer p. 22
Paint p. 23
Melamine p. 23
This code comprises the following value:B little or no contribution to the spread of fires1 little or insignificant smoke emissiond0 no flammable particles or drops in the event of a fire
The system is broken down into the following categories:A1 no contribution to the spread of fireA2 no significant contribution to the spread of fireB little or no contribution to the spread of fireC limited contribution to the spread of fireD contributor to the spread of fireE major contributor to the spread of fire
OVERVIEW OF SPECIAL CORE PANELS
TE
CH
NIC
CONTENT OF UREA-FORMALDEHYDE
We only use class E05 panels or panels glued without any addition of urea formaldehyde whatsoever. An overview of the panels we use is provided here.
All US Products are ordered as NoAdded Formaldehyde as a Standard.
TOPAKUSTIK, with MDF fibreboard bonded without formaldehyde, has been examined for volatile pollutants as per ISO 1600: it was awarded the best possible classification (A+).
Finish No add. urea formaldehyde Class E05
Veneered On request Products
Colour or white lacquered Standard products Special products
Eco (melamine finish) Standard products Special products
FOR EXAMPLE: BLACK MDF
Black or coloured MDF core boards offer many interesting possibilites. They contrast well with both painted and wood veneer TOPAKUSTIK planks or panels.
When the core is the finish: All of the core panels are industrially manufactured. Colour differences, even within one production batch, cannot be avoided. The application of a topcoat can make these differences even more apparent.
EXPANSION AND CONTRACTION OF THE CORE MATERIALS:
Wooden materials are hygroscopic and have a balancing effect on the relative humidity of the room. Changing room humidity also causes the shrinkage and expansion of wooden materials. In air conditioned rooms the panel and plank dimensions can change by +/– 1 mm per 1000 mm. In non air conditioned rooms this can increase to +/– 2 mm per 1000 mm. Therefore panels and planks should be separated with joints of 3 mm to 6 mm depending on their size.
Acclimatise:The installation should only be done when the normal operating humidity and temperature conditions are in place. The elements are to be acclimatised inside the installation room 3 – 4 days before installation. Take care elements are exposed evenly to the room air. For more detailed information, please consult the «guidelines for TOPAKUSTIK and TOPPERFO» in the installation manual.
Table of Classification
CH DIN EN US
RF 1 A1 A1s1,d0 A
RF 1 A2 A2s1,d0 A
RF 2 B1 Bs2,d0 A
RF 3 B2 Ds2,d0 C
as an indication
US classifications according to ASTM E84 standard
22 23
PA INT SURFACES
Matching is available for any manufacturer‘s colour specification (RAL / NCS / …). The application is done with the latest generation spray robotics, providing a guaranteed even application. Due to the grooves and perforations of the products, the colour appearance is different from that on smooth surfaces. If TOPAKUSTIK products are finished by the client, please remember that an even paint application, even in the grooves, is absolutely necessary for a good final result.
The advantage of painted surfaces is that the grooves are also the same colour.
White coating in MDFeco melamine gives the grooves greater prominence.
TE
CH
NIC
Oak M3280 NTL Maple M2106 SMA Beech M3247 SMA Cherry M760 SMA Walnut M4462 SMA
Ash M3965 NTL White B3002 LP Silver L4068 LP Acacia M4451 NTL Oak Rustic M6263 NTL
basic: 4100 × 2070 mm 5600 × 2070 mm
extra: 4100 × 2070 mm
MELAMINE (eco)
Details for eco:– 12 different cuttingedge Decors– All panels are classified as no added urea formaldehyde NAUF– Short delivery times, all decors in stock NH– Both fire classes available Ds2,d0 (B2) and Bs1,d0 (B1)– FSC mix possible on request (depending on quantity)
WOOD VENEERED
SURFACES:
The TOPAKUSTIK products are veneered in all customary types of wood. The veneer are processed individually for each order. This helps to obtain the most even appearance possible for colour and pattern. Furthermore, the veneer appearance is influenced by the cut and the composition of the veneers. Since wood is a natural product, the matching of the veneer must be done in connection with each individual order.
Oak Europe Knotty Oak Oak Optic ST2002 Maple US Birch Ash
am. Nut Tree/Walnut Cherry US
Quarter cut + Random matched Quarter cut Quarter cut Crown cut Crown cuthalf crown cut slip matched book matched slip matched book matched
VARNISH:
A high quality, clear, flat varnish is provided on all orders unless otherwise specified. Light kinds of wood such as maple or birch are varnished with a slight lightening effect as a matter of principle.
NM = natural, gloss varnish AM = lightening, gloss varnish
Different lengths of planks and panels: The choice of the veneers is tailored to the length of the plank or panel. Different veneers may be used for various lengths. If the entire project needs to be manufactured using the same veneer, that needs to be specified as a condition.Rift veneers (sliced veneers or true quarters) on panels:joining rift veneers on the bias is not advisable with certain types of wood such as maple or cherry as the appearance of the veneers becomes striped. We recommend random match veneering = our ‚Random matched‘ range.
Advantage: uniform impression for whole project Disadvantage: not uniform impression for whole project
Collection 209( subject to a nominal charge ) 20 coloured natural wood veneer and9 Natural wood veneer
… and many other types of wood
You can use our configurator to choose your veneer and perforation. The effect can be seen immediately.See www.topakustik.com
eco plus collection: Further melamine finishes for quantities above 150 m2 upon request.
HPL coating: All customary HPL laminate coatings are possible. Contact the factory for details.
Concrete F2204 STU Oxyde F2195 STU
stone: 5600 × 2070 mm NEW!
44
14
30
50
30
50
F: +41 41 679 73 79P: +41 41 679 73 73
WWW.TOPAKUSTIK.CH
N'H AKUSTIK + DESIGN AGOBSEESTRASSE 11CH-6078 LUNGERN, SWITZERLAND
Gez.Plan Nr.Auftr.Nr.
Rev.Dat.Wandecke Typ 27 anw
L:\03_AVOR_Dokumente\02_Avor_Vorlagen_CAD_Bestellungen_Stücklisten\04_CAD-CadWork\01_CAD_Detail-Bibliotek\5. Randstäbe_Wand u. Decken Abschlüsse\5.27_Typ 27\527_Wandecke Typ 27.2d
Mst.Dat.
1:116.5.13
527
Seite 23
© "unsere Dokumente unterliegen ausdrücklich dem Copyright"
10
12
3030
503 20
24 25
Groove interrupted at edge
For blind edges, perforations are visible
TOPAKUSTIK-Panels edge details:
EDGES
TOPAKUSTIK-planks edge details:
Longitudinal edges with tongue and groove.If requested an extra groove can be inserted for fitting with a mounting clip. Transverse edges are cut industrialy and at a 90 degree angle. When planks of multiple lengths are requested, the perforations are visible on the front edge.
If requested, perforations on the transverse edges are set back. Edge varnished. The rear stress relief grooves are necessary for stability and are visible.
If requested, the first and last plank may have a visible edge without tongue or groove. It may also be veneered or painted.
Product tolerancesPlanks: the front edges of TOPAKUSTIK planks are supplied with a industrial 90 degree angle cut as a standard. The length tolerance amounts
to + / – 3 mm. If requested, the planks can be supplied to a «fixed» dimension with a reduced tolerance of approx. + / – 0.25 mm per m1. This is only recommended for lengths shorter than 2 m because of the potential for greater expansion and contraction of core materials.
Panels: TOPAKUSTIK panels are produced on computer controlled machinery with tolerances of + / – 0.5 mm per m1).
TOPAKUSTIK products are delivered with small tolerances as above. By grooving and perforating, the surface area is increased by a factor of two or three, depending on the design. Therefore TOPAKUSTIK products can react quickly to varying humidity and temperature conditions. Size differences can occur before installation caused by expansion and contraction of core materials during storage and acclimatization. (> page 20)
Visible edge, perforation set back(Edge finished in coloured paint version!)
Female rabbet joint 4 mm deep for a spline joint
CEIL ING F IN ISHES FOR PLANKS + PANELS
Edge Moulding Type 1 Edge Moulding Type 2 Edge Moulding Type 3
CEIL ING F IN ISHES FOR PANELS
Mitre Type 10 Visible Edge with Grooves set back Visible Edge with continuous grooves Type 11 Type 12
CUTOUTS
On site or factory cut Produced with interrupted grooves Inserts for planks 128 / 256 / 384 mm
WALL CORNERS AND TERMINATIONS
Type 21 (Alu elox. nat. 35·3 mm) Type 22 (Alu elox. nat. 10 mm) Type 23 (Alu elox. nat. 12 mm)
Type 27 Type 25 Type 26 (Alu elox. nat. 30·20·3 mm)
TE
CH
NIC
Lamellen-Montage mit Klammern
Lamellen-Montage mit Drehclips
47
128
36 36
128
RiegelsetRiegelsetRiegelsetRiegelset
Lamellen-Montage mit Klammern
Lamellen-Montage mit Drehclips
110
110
x · 16 mm
9080
MontagehandbuchBitte vor Montagebeginn lesenAusgabe 2017
Montagehandbuch_alle Sprachen_V2017.indd 1
20.04.2017 17:30:43
26 27
MOUNTING OF TOPAKUSTIK PLANKS
Mounting on wooden Battens: The TOPAKUSTIK planks are installed like conventional tongue and groove planks. It is important that compressed air pressure used for the nailing or stapling gun is set precisely, so the staples do not protrude in the groove or penetrate too deeply.
Mounting on Metal Ceiling Grids: The TOPAKUSTIK plank is fitted to the suspended H-bar rail with special «twist on» mounting clips. This form of assembly is ideal for non-flammable ceiling finishes.
ACCESS PANEL
closed:
open:
LAYOUT
Offset joints: The installation with offset joints permits a slight material expansion without it becoming visible. In combination with joint widths of about 3 mm, a clear and tidy joint apppearance results.
English Serrated Random
MOUNTING OF TOPAKUST IK-PANELS
Z-System: Every other panel is inserted and can easily be removed by lifting. This system is suitable for all ceilings. Recommended planning width of panels (axe) = 642 mmPanel joints = width of grooves + 2 mm (e.g., 14/2 = 2 + 2 = joint 4 mm)
G-System: Each panel is easy to remove by lifting. Recommended planning width of panels (axe) = 642 mmPanel joints = width of grooves + 2 mm (e.g., 14/2 = 2 + 2 = joint 4 mm)
S11: Each panel is easy to remove.Recommended width of panel 640 mm incl. joint* (multiple of 16 mm) * Panel joints : appr. double width of grooves (2 = 4, 3 = 5, 4 = 6 mm)Max. panel length = 2510 mm
LAYOUT
Offset joints: The installation with offset joints permits a slight material expansion without it becoming visible. In combination with joint widths of about 3 mm, a clear and tidy joint appearance results.
Parallel – English Serrated Not recommended for G-System
TE
CH
NIC
open
closed
Narrow grooving (Type 6/2, 8/3, 9/2) is not suitable for the system S11
Planks are manufactured with a precise large notch finger joint ,which permits a plain ceiling design. However, individual planks or joints may be visible, in particular if dark colours or shiny varnishes are used. The planks are installed without dilation joint, which is only possible because of the narrow plank width of «just» 128 mm. However, it is mandatory to observe the installation rules regarding room climate – see page 20!
Joints have two functions: Absorbing material dilatation and allowing panels to be demounted. Panel joints for this reason can not be hidden in copying the width of the grooves to the joints of panels. As a general rule we recommend adding 2 mm to the grooving. For example, for 2 mm grooves (14/2 or 19/2…) this means: 2 + 2 mm results in a joint of 4 mm. It is extremely important to observe the installation rules regarding room climate – see page 20!
Narrow grooving (Typ 6/2, 8/3, 9/2) is not suitable for this system
… for more information see installation manual!
… SMALLER AND
SMALLER!
For a long time, high sound absorption was equated with large open areas that also entailed large perforations. However, architects and designers wanted, and still want, to make the perforations less visible. Following the launch of our TOPPERFO-T and TOPPERFO-Clou products with smaller perforations, we have now achieved hole diameters of a mere 0.5 mm or even 0.3 mm with our TOPPERFO-Micro range. In other words, the circle has been squared: small perforations and high sound absorption combined in one and the same product!
Living room, Küsnacht am Zürichsee CHArchitect: Sybille Cartier Vogt, Erlenbach – Photo: Sibylle Kathriner Fotografie, StansProduct: TOPPERFO-Micro 2/2/0.5, white lacquered
The ceiling cladding in this family home on Lake Zurich exudes cool elegance. The neutral ceiling surface enhances the tasteful decor rather than competing with it. The functioning of the room acoustics is virtually invisible.
Montagehandbuch
Bitte vor Montagebeginn lesenAusgabe 2017
Montagehandbuch_alle Sprachen_V2017.indd 1
20.04.2017 17:30:43
31 30
TOPPERFO are perforated acoustic panels tailor made specifically for each project. Various panel sizes and hole diameters are available for selection. TOPPERFO-Micro and TOPPERFO-Clou, developed by NH, are discrete in their appearance and simultaneously very effective in sound absorption thanks to the small hole diameters. TOPPERFO panels can be provided with various edge designs.
T-Perforation: For absorption in the low to medium frequency range. The absorption in the low-frequency range is based on the combination of small diameter holes on the visible side and larger diameter holes on the rear. The small perforations present an aesthetic surface suited for wall finishes.
M-Perforation: For absorption in the medium to high frequency range. The absorption depends on the percentage open area, the depth of the rear air cavity between the acoustic elements and the ceiling or wall and the porous absorption in the cavity.
Reflector: TOPPERFO products can also be used as reflectors by eliminating the perforations on the rear surface. The absorption figures are then equivalent to those of a standard reflecting panel.
THE ACOUSTIC SYSTEM
All TOPPERFO types are available with M and T perforations on the rear. This makes it possible for acousticians to match the TOPPERFO surface treatment with the required absorption. The absorption coefficients stated in this brochure were measured according to the ISO 354 standard as described previously. Additional absorption coefficients with other porous materials in the air cavity (e.g. only fleece, melamine resin foam, fiber-glass, etc.) are listed in the TOPAKUSTIK / TOPPERFO sound absorption document.
MOUNTING
DIMENSIONS AND MATERIALS
PANELS (Planks see page 34)
Clean cut With surrounding groove Visible edge and tongue
EDGES
TOPPERFO-M, Ø 6 mmSpecial screws: in half depth «dummy» perforations
TOPPERFO-M, Ø 8 mmWith insert from rear side
TOPPERFO-T, Ø 4 + 5 mmSpecial screws:in half depth «dummy» perforations
See installation manual!
Fire category – more information page 20 / 21
page 22 / 23
… or according to your specifi-cations
Large perforation diameters may be problematic due to the strong light and dark contrast > risk of flickering!Recommendation: use fine perforations for wall panels (TOPPERFO-T, -Clou or -Micro).
Clou Perforation in core panels with nor-mal flammability. Developed on the basis of T-Perforation, our Clou Perforation product features even smaller bore dia-meters, starting at 1.2 mm. The sound energy is channelled through four bores on the visible side into one larger bore on the rear side. Materials other than MDF can also be used for core panels.
Clou Perforation in low-flammability or non-flammable core panels. The bore on the rear side is replaced by a groove that has a slight influence on the absorption values – note the measurements. The perforation on the visible side remains the same on low-flammability panels; the minimum diameter for non-flammable core panels is 2 mm.
Micro Perforation delivers convincingly high sound absorption – but it can’t be seen! The core panel is fully perforated and the covering, veneer or coating mate-rial is micro-perforated. TOPPERFO-Micro is suitable for almost all areas, except for outdoor applications.
not fire rated D-s2,d0 / CH RF 3 fire retardant B-s1,d0 / CH RF 2 RESAP® Core non-flammable
Paint
16 mm
Wood Veneer
17 mm
Melamine
16 mm
Paint
16 mm
Wood Veneer
17 mm
Melamine
16 mm
Paint
16 mm
Wood Veneer
17 mm
Standard = Matched to MDF Core Sizes
2040 × 992 / 640 2040 × 992 / 640 2040 × 992/640 2040 × 992/640 2040 × 992/640 2040 × 992/640 1540 × 608 1540 × 608
2780 × 992 / 640 2780 × 992 / 640 2780 × 992/640 2780 × 992/640 2780 × 992/640 2780 × 992/640 2540 × 608 2540 × 608
3640 × 608 3080 × 608 3080 × 608
4080 × 640 4080 × 640 4080 × 640 4080 × 640 4080 × 640 4080 × 640
custom lengths are also available – Max width depends on raw panel, approx. 1200–1250 mm
Date 2022 – please check the current dimensions on www.topakustik.com
depending wood depending wood
11 12 1311 12 1311 12 1311 12 1311 12 1311 12 13
a w Euro NRC
0.60 LM C 0.80
0.55 LM D 0.85
a w Euro NRC
0.90 A 0.95
0.90 A 0.95
a w Euro NRC
0.80 L B 0.95
0.75 LM C 0.95
125
250
500
1000
2000
4000 125
250
500
1000
2000
4000 125
250
500
1000
2000
4000
1.21
0.80.60.40.2
0a sHz
1.8/1.8/0.5
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
3/3/0.5
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
2/2/0.5
2/2/0.5
3/3/0.51.8/1.8/0.52/2/0.5
16 17 18
- M i c r o
33 32
With TOPPERFO-Micro, the sound absorption function becomes almost completely invisible. The perforation measures a mere 0.5 mm, so it is virtually invisible from a certain dis-tance. TOPPERFO micro-perforation is available in various grids and diameters, depending on the required level of sound absorption. The choice of surface coverings is also virtually unrestricted. All veneers and paint colours are available, as well as CPL and HPL surfaces by arrangement.
Micro-perforation for almost all boards! We transform industrially manufactured boards “directly” into a sound absorber! For example:- Melamine-coated boards – see our Eco collection, page 23- Branchless three-layer or solid boards – see support plate, page 19- MDF boards veneered by a joinery (> 800 x 300 mm)- Black or coloured MDF core (page 21)…and many more
M I C R O - D I R E C T
The micro-perforation is provided in fields with a width of around 150 mm. In sided light, it is possible that the excess length between the individual fields becomes visible on UniEco decors or if a dark colour varnish is used. The grid 1.8/1.8 is therefore not recommended for these surfaces. For a grid of 2/2, we recom-mend to provide samples.
TOTAL THICKNESS
ca. 226 mm
ca. 66 mm
MW 40 mm
16 Galerie Lafayette, Paris FR – Architect/Photo: CALQ Architecture, Paris FR 17 Kantonsspital, Luzern CH – Architect: Schärli Architekten, Luzern CH – Photo: Kantonsspital, Luzern CH 18 Ericusspitze, Hamburg DE – Architect: Henning Larsen Architects, Kopenhagen DK – Photo: Anke Müllerklein, Hamburg DE
125
250
500
1000
2000
4000
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
1.21
0.80.60.40.2
0
a w Euro NRC
0,60 LM C 0,75
0,60 LM C 0,80
a w Euro NRC
0,65 L C 0,80
0,65 LM C 0,85
128 mm
1 mm
Micro 1,8/1,8/0,5Micro 2/2/0,5
19 2120
35
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
34
TOPPERFO-Micro planks are easy to install as they are laid like traditional panelling. The width of 128 mm with a 1 mm separation joint allows for expansion tolerance.
Ideal lengths:MDF 16mm B-s1,d0 (CH RF2): 2780 / 3640 / 4080 mm MDF 16mm D-s2,d0 (CH RF3): 2780 / / 4080 mm
Surfaces:
Real wood veneer - length dependent on veneer type
Paint
Melamine Eco Collection 2.0 (see page 23)
H-System – with turning clips on H-profile
T-System – with turning clips on T-profile
SC-System – with screw clips on wooden batten or metal substructure
W-System – with staple machine on wooden battens
TOTAL THICKNESS
ca. 226 mm
ca. 66 mm
MW 40 mm
Graphic designs and patterns are available in every imaginable form. Would you like a portrait, or do you prefer an abstract pattern? The possibilities are virtually limitless.The back cover of this brochure shows a project featuring an abstract pattern.
TOPPERFO-Micro is also ideal for printed walls or ceilings.Because the Clou- or Micro-perforation is almost invisible, it does not clash with the printed subject – but the surface still absorbs sound. At the DaVinci College high school in Roosendaal (Netherlands), the pupils› imaginative versions of the Mona Lisa were assembled to create a very unusual collage.
M I C R O - G R A P H I C D I G I TA L P R I N T
19 4 Times Square Durst building, New York, USA – Architect: Studios Architecture, New York – Photo: @jeremyfrechette 20 Lycée Edward Steichen, Clervaux LUX – Architect: Jonas Architectes Associés SA, Ettelbruck LUX – Photo: Stephan Offermann, LUX 21 Mona Lisa, Da Vinci College, NL – Architect: Ector Hoogstad Architecten, Rotterdam NL, Photo: Petra Appelhof Fotografie, Nijmegen NL
- M i c r o P l a n k s
a w Euro NRC
0.30 LM D 0.55
0.30 LM D 0.60
a w Euro NRC
0.55 LM D 0.80
0.55 LM D 0.80
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000
a s
125
250
500
1000
2000
4000 Hz
125
250
500
1000
2000
4000
10.3.2
Abhängehöhe 216 mmAbhängehöhe 76 mm
Seite 32 zwischen die beiden bestehenden
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
Seite 32 - 10-3-2_TOPP_Clou_8-8-1.2_216-76.xls 23.08.2016
10.5.3
Abhängehöhe 246 mmAbhängehöhe 96 mm
Seite 32 - ganz rechts einfügen
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
Seite 32 - 10-5-3_TOPP-Clou_8-8-2_246-96.xls 23.08.2016
a w Euro NRC
0.25 LM E 0.45
0.25 LM E 0.50
a w Euro NRC
0.45 LM D 0.75
0.45 LM D 0.75
125
250
500
1000
2000
4000
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000
a w Euro NRC
0.70 L C 0.80
0.70 M C 0.85
a sHz
125
250
500
1000
2000
4000
a w Euro NRC
0.55 LM D 0.75
0.50 LM D 0.80
1.21
0.80.60.40.2
0a s
125
250
500
1000
2000
4000
a w Euro NRC
0.40 LM D 0.65
0.35 LM D 0.70
Diagramm.x ls
16/16/10-3 Seite 31
Abhängehöhe 50 mm 200 mm
100 0.09 0.320.14 0.42
160 0.26 Tiefton 0.55 Tiefton0.49 0.44 0.78 0.62
250 0.72 0.760.95 0.91
400 1.1 0.841.06 0.75
630 0.93 Mittelton 0.73 Mittelton0.73 0.81 0.67 0.69
1000 0.6 0.650.45 0.52
1600 0.37 0.430.33 0.37
2500 0.27 Hochton 0.31 Hochton0.24 0.27 0.28 0.31
4000 0.21 0.240.18 0.2
23.4.2004 ac
Hz
-Clou 8 / 8 /1.2 8 / 8 / 2 - T 16 /16 /10 - 5 16 /16 /10 - 4 ( 3 )
16/16/10-5 16/16/10-4 16/16/10-3
8
8
Ø 1.2 mm 8
8
Ø 2 mm 16
16
Ø 5 16
16
Ø 4
22 2423
36 37
8/8/1.2 Rear perforated 8/8/2 Rear grooved8/8/1.2 Rear grooved 8/8/2 Rear perforated
The fine Clou perforation in an 8 mm grid with a diameter of only 1.2 mm can hardly be seen at a distance. The wooden texture is therefore com-pletely retained in its natural beauty.
Clou perforation is provided over the whole surface to add the benefit of a shine The middle of the last perforation row should therefore be at the following distance from the board edge:Grid 8/8 x = max. 6,5 mm Grid 6,4/6,4 x = max. 5,0 mm Grid 5,3/5,3 x = max. 4,0 mm
MDF not fire rated perfora-ted
Ø 1.2 mm Ø 2.0 mm
MDF fire retardantgrooved Ø 2.0 mm
Resap
rear
8 / 8
6.4 /
6.4
5.3 /
5.3
x
x TOTAL THICKNESS
≈ 216/246 mm
≈ 76/96 mm
More information Page 4
The T-perforation developed and successfully used by Topakustik AG has a discreet effect, yet offers appreciable absorption. TOPPERFO-T panels are available with perforation bores of x 3, 4 and 5 mm. Decreasing the diameter of the visible perforations, shifts the absorption maximum to a lower frequency.
See page 31 for dimensions and materialsSee page 22 / 23 for surfaces
22 APA Tower, USA – Architect: Gensler, USA – Photo: Keith Trotta, USA 23 Swiss Lounge, Flughafen Zürich CH – Architect: Greutmann Bolzer AG für Gestaltung, ZH CH – Photo: Valentin Jeck, Stäfa CH 24 Sporthalle, Niederglatt CH – Architect: L3P Architekten, Regensberg CH – Photo: Vito Stallone, Dottikon CH
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000
a w Euro NRC
0.50 LM D 0.80
0.50 M D 0.75
Hza s
125
250
500
1000
2000
4000
a w Euro NRC
0.95 A 0.95
0.90 A 0.90
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000
a w Euro NRC
0.75 LM C 0.90
0.70 M C 0.80
a sHz
5.17.1
Abhängehöhe 216 mmAbhängehöhe 56 mmSeite 37
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
Seite 37 - 5-17-1_TOPP_M_16-16-10_216-56.xls 21.08.2015
125
250
500
1000
2000
4000 125
250
500
1000
2000
4000 Hz
5.12.3
15.20%Abhängehöhe 200 mmAbhängehöhe 60 mmSeite 39
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
Seite 39 - 5-12-3_TOPP_M-Graphic-16-16-8_200-60.xls 05.07.2016
5.12.4
Abhängehöhe 200 mmAbhängehöhe 56 mm
11.50%Seite 39
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
Seite 39 - 5-12-4_TOPP_M-Graphic B-16-16-8_200-56.xls 05.07.2016
a w Euro NRC
0.65 C 0.60
0.65 C 0.60
a w Euro NRC
0.75 C 0.70
0.75 C 0.70
- M 16 /16 / 6 16 /16 / 8 (10 )
16/16/6-12% 16/16/8-20% 16/16/10-30%
- G r a p h i c
16
16
Ø 6 16
16
Ø 8
2725 26
39 38
25 Ernst & Young, London GB – Architect: Perkins + Will, London GB – Photo: David Churchill, Hove GB 26 Devon Energy, USA – Architect: Kendall Heaton Architects, Houston USA 27 Affenhaus, Zoo Basel CH – Architect: Peter Stiner, Basel CH – Photo: Zoo Basel CH
TOPPERFO-M are acoustic panels in their conventional form in all materials and sur-faces. Perforation-free edges and un-perfo-rated borders for cut-outs are available as a client’s choice. Other hole spacings and bore diameters are available upon request.
See page 31 for dimensions and materialsSee page 22 / 23 for surfaces
Offset 16/20/40
x y Ø open area ISO 354
16 16 6 12 % ✓
16 16 8 19 % ✓
16 16 10 31 % ✓
40 40 10 5 % ✓
20 20 10 20 % ✓
20 20 8 12 % ✓
20 20 6 7 % ✓
Hole spacings andbore diameters
… and many others! TOTAL THICKNESS
≈ 215 mm
≈ 55 mm
More information Page 4
UNO GRAPHICIndividual perforations are exposed to create a graphic pattern. This page shows just a few ideas, but the possibilities are almost unlimited. The only rule: the bore grid of 16 mm must always be observed. Sound absorption values are available for «minus 20 %» and «minus 40 %» of the perforation.
GRAPHIC MULT IMultiple bore diameters offer considerably more possibilities, but production is also more complex.
Many other designs under www.topakustik.ch/products/topperfo/graphic
16/16/8-15 % 16/16/8-11 %« minus 20 % » « minus 40 % »
Star 8 Text 8 (or 6) Rain 8 Rollo
Phot
os:
Fact
ory
TOPA
KUST
IK A
G
a w Euro NRC
0.80 B 0.80
0.80 B 0.75
a w Euro NRC
0.65 C 0.65
0.70 C 0.65
a w Euro NRC
0.50 L D 0.50
0.50 D 0.50
9.4.1
Abhängehöhe 200 mmAbhängehöhe 56 mm
Seite 38
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
Seite 38 - 9-4-1_TOPP-Split 96-32-72_200-56.xls 20.10.2016
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
0.00
0.20
0.40
0.60
0.80
1.00
1.20
100
160
250
400
630
1000
1600
2500
4000
Split 96/32/72-8Bubble 2.0 (7%) Bubble 3.0 (12.5%)
594 mm
594
mm
1194 mm
594
mm
6
15/24
15/24
15
125
250
500
1000
2000
4000 Hz
1.21
0.80.60.40.2
0
125
250
500
1000
2000
4000 125
250
500
1000
2000
4000
a s
28 29 30 31
32
41 40
Three different holes Longitudinal slots
TOTAL THICKNESS
≈ 215 mm
≈ 55 mm
More information Page 4
Would you like a special perforation?TOPPERFO-Bubble, that is three different drill diameters, which we now offer in two different open areas.Or longitudinal milling? We offer these under the product name TOPPERFO-Split.
NEW!
28 Kantonalbank Graubünden, Chur CH – Architect: Domenig Architekten, Chur CH – Photo: Feiner Ralph, Chur CH 29 Altersheim Obere Mühle, Lenzburg CH – Architect: Oliv Brunner Volk, ZH CH 30 Restaurant Compas, Vernier CH 31 TOPAKUSTIK Sixty Typ 29/3 M 32 TOPPERFO Sixty Typ M, 16/16/6
SIXTY-SYSTEM
(US = 2x2 GRID PANELS)
The ceiling system offering maximum choice and extremely easy assembly. Sixty-System 2 x 2 grid panels fit into all standard T-pro-files.
Opening upwards: types A, B and C
Opening downwards: type D
Only available with ungrooved borders (exept 29/3)
Type D
Type A
Type B
Type C
Ungrooved borders
Groovingwithout border
Ungrooved borders
Groovingwithout border
- S p e c i a l B u b b l e S p l i t
COLL ABORAT ION
We offer far more than innovative products that bring together architec-tural materials with acoustical performance. Our strength in systems engineering coupled with the excellent craftsmanship of our fabricators allows us to also bridge invention and reality. We offer time tested engineering and installation strategies for the most unique projects. Early design motifs can be quickly adapted into prototyping for feasibility studies, and our design commitment maintains its endurance through the entire project lifecycle to final commissioning. Our goal is to both encourage creativity and meet its demands.
Falkonergårdens Gymnasium DKArchitect: Falko Arkitekter, Copenhagen – Photo: Stamers Kontor, CopenhagenProduct: TOPPERFO-M 16/16/8, Oak veneered
The extension built onto the Falkonergården high school in Frederiks-berg, Denmark, houses a rather unusual gymnasium. The Falko Arki-tekter firm created an additional space between two traditional brick buildings, providing accommodation for sports as well as meetings. TOPPERFO panels with a large M-perforation alternating with smooth veneered areas were used for the wall claddings. The installation was slightly curved.
Formelemente Formelemente r>2mr>2m
Formelemente Formelemente
r>2mr>2m
Dublextüren
22.07.2016
830
P: +41 41 679 73 73F: +41 41 679 73 79WWW.TOPAKUSTIK.CH
N'H AKUSTIK + DESIGN AGOBSEESTRASSE 11CH-6078 LUNGERN, SWITZERLAND
Gez.Plan Nr.
anw
L:\03_AVOR_Dokumente\02_Avor_Vorlagen_CAD_Bestellungen_Stücklisten\04_CAD-CadWork\01_CAD_Detail-Bibliotek\8. Schranktüren\800 Akustik Türen.2d
Mst.Dat.
1:1/1:1011.3.13Topakustik Türen Dublex
32
RK-Türen
22.07.2016
P: +41 41 679 73 73F: +41 41 679 73 79WWW.TOPAKUSTIK.CH
N'H AKUSTIK + DESIGN AGOBSEESTRASSE 11CH-6078 LUNGERN, SWITZERLAND
Gez.Plan Nr.
anw
L:\03_AVOR_Dokumente\02_Avor_Vorlagen_CAD_Bestellungen_Stücklisten\04_CAD-CadWork\01_CAD_Detail-Bibliotek\8. Schranktüren\800 Akustik Türen.2d
Mst.Dat.
1:1/1:105.3.13Topakustik Türen RK 810
31
33 34 35
44 45
In conjunction with the fleece attached to the inside (RK 280), the acoustic surface ensures an absorption across the entire frequency band.The fleece developed by NH is tear-proof and set back from the hinges and handles.
→ 3 point-lock must be used!
Duplex is particularly suited to large hinged or sliding doors. These have invisible, integrated absorptive panels.
→ 3 point-lock must be used!
sw* is comparable to Duplex
CABINET FRONTS
Cabinet fronts or rear walls of cabinets can be used as sound absorbers. The following products are most suitable: TOPAKUSTIK 14 / 2, 19 / 2, 6/2, TOPPERFO-Micro/-T and Clou.
Type RK
FORMED SHAPES
For ceiling clouds, curved walls and other shapes TOPAKUSTIK and TOPPERFO elements can be used for shaped wall and ceiling finishes without significant additional effort. For radii above 10 metres, the standard TOPAKUSTIK planks are assembled on the round sub-construction in a segmented way. For smaller radii, the planks or panels can be made flexible by deeper relief grooving on the rear side. In this way, the panels can simply be adapted to the curved sub-construction.
Grooving
Gro
ovin
g
Convex
Concave
Convex
Concave
Radius Machining
Planks > 10 m> 5 m
Assembled in segmentsGrooved on the back
Panels > 5 m> 1 m
Grooved on the backPrepared as shapes in the factory
Radius Machining
Planks > 15 m> 8 m
No special machiningGrooved on the back
Panels > 8 m> 1 m
Grooved on the backPrepared as shapes in the factory
Door RK inside
Type Duplex
Type a w Euro NRC
sw* 16/16/12-3 0.25 (L) E 0.27
sw* Clou 8/8/1.2 0.35 (L) D 0.39
Type a w Euro NRC
RK 9/2 M 0.55 D 0.56
RK 14/2 M 0.60 (H) C 0.68
TOPAKUSTIK:Type a w Euro NRC
RK Clou 8/8/1.2 0.35 (LM) D 0.54
RK Micro 2/2/0.5 0.7 C 0.82
TOPPERFO:
Type a w Euro NRC
sw* 14/2 M 0.50 D 0.55
TOPAKUSTIK: TOPPERFO:
33 Centre scolaire, Fully CH – Architect: Suter Sauthier Achitectes SA, Sion CH – Photo: Patrick Zufferey, Sierre CH 34 Binagadi Auditorium, AZE – Architect: Lider Monolit, Baku AZE – Photo: Idris Ahadov, Baku AZE 35 EKZ, Dietikon CH
36 37 38
46 47
GYMNASIA
Wall and ceiling finishes are subjected to high impacts in gymnasia. TOPAKUSTIK and TOPPERFO finishes, in combination with the subconstruc-tion systems specifically developed for sports venues, fulfil the high requirements with regard to physical impact and room acoustics.Various TOPAKUSTIK and TOPPERFO products have been tested and certified to DIN 18 032 part 3.
SWIMMING POOLS
For acoustic finishes in high humidity rooms, requirements corresponding to the application are to be fulfilled, e.g.:
• Ceilings and walls constructed to local code requirements• Rear ventilation of wall and ceiling finish• Use of corrosion-proof subconstruction materials• Use of specific, moisture-resistant core panels in production• Use of specific varnishes or impregnations• Consideration of the (extraordinary) shrinkage and swelling properties of the core panels• Water-repellent absorbers such as polyester fleece
The use of acoustic surfaces in damp areas is highly complex. Please contact us with your project and we shall be happy to assist you with deve-loping it.
SchwimmbSchwimmbääderder
36 Centre scolaire, Salvan CH – Architect: Bonnard Wœffray Architectes, Monthey CH – Photo: Patrick Zufferey, Sierre CH 37 École de Châteauneuf, Conthey CH – Architect: Bonnard Wœffray Architectes, Monthey CH – Photo: Patrick Zufferey, Sierre CH 38 Infinity House, GB – Architect: Spaced Out Ltd., London GB – Photo: Josh Pulman, London GB
L 4266-III / IV 13/3M, 12 % Planks MDF 19 mmL 4266-IV / IV 28/4M, 7.5 % Planks MDF 19 mmL 4266-I / IV 16/16/8 Panels MDF 19 mmL 4266-II / IV 16/16/10-5 Panels MDF 19 mmL 4266-I / II 16/16/8 Impact wall testL 4266-II / II 28/4M Impact wall test
SchwimmbSchwimmbääderder
1
USA-PATENTPATENTNo 5, 362, 931No 5, 422, 446
EU-PATENTPATENTNo 0504629
CH-PATENTPATENTNo 683 112
40
42
39
41
48 49 49
QUAL ITY IS NEVER A COINCIDENCE
What we do, we do perfectly: to the highest quality for our customers,
with respect for the environment, with products that comply with EN standards
and with world-wide patent protection for our inventions.
are registered brands of Topakustik AG
FSC products are marked
39 KKL, Luzern CH Architect: Jean Nouvel, Paris FR40 Reichstag Berlin DE Architect: Foster + Partner, London GB41 New York Times, New York USA Architect: Renzo Piano, Genova / Paris 42 Burj Khalifa 828 m, UAE Architect: Adrian Smith SOM, Chicago USA Rear cover photo: Micro Graphic
TOPAKUSTIK-SERVICE
VISIT OUR PLANT IN LUNGERN
Our company headquarters and the Production site in Lungern are 30 minutes south of Lucerne, accessible by rail or road.
TOPAKUSTIK installation manual with sub-construc-tions, guidelines and tips for the tried and tested TOPAKUSTIK installation systems. For specific installation solutions, please contact our technical department.
Deluxe sample box(subject to a nominal charge)17 different samplesincluding 5 differentveneers
Basic sample box
Eco sample box
ARIA sample box
A5 sample from stock:
TOPPERFO whi
te
RAL
9010
Beec
hst
eam
ed
Map
le
euro
pean
Birc
h
Oak
eu
rope
an
Am.
Wal
nut
Am
. C
herr
y
Map
le
kana
disc
h
whi
te
B300
2 LP
light
gra
y L4
068L
P
Oak
32
80N
TL
Ash
M39
65N
TL
Map
le
M21
06N
M
Beec
h-M
3247
SMA
Wal
nut
M44
62N
M
Chee
ry
M76
0NM
Acac
ia
M44
51N
TL
Oak
M
6263
NTL
Micro 2/2/0.5 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Micro 3/3/0.5 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Clou 8/8/1.2 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Clou 8/8/2 ✓ ✓
T 16/16/10-3 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
T 16/16/10-4 ✓ ✓
T 16/16/10-5 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
M 16/16/6 ✓ ✓ ✓
M 16/16/8 ✓ ✓ ✓
M 16/16/10 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
M 20/20/8 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
TOPAKUSTIK whi
te
RAL
9010
Beec
hst
eam
ed
Map
le
euro
pean
Birc
h
Oak
eu
rope
an
Am.
Wal
nut
Am
. C
herr
y
Map
le
kana
disc
h
whi
te
B300
2 LP
light
gra
y L4
068L
P
Oak
32
80N
TL
Ash
M39
65N
TL
Map
le
M21
06N
M
Beec
h-M
3247
SMA
Wal
nut
M44
62N
M
Chee
ry
M76
0NM
Acac
ia
M44
51N
TL
Oak
M
6263
NTL
6/2 M 7 % ✓ ✓ ✓ ✓ ✓ ✓
8/3 M 19 %9/2 M 6 %9/2 HR 6 % ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
13/3 M 12 %12/4 M 15 % ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
14/2 M 7 %19/2 M 6 %28/4 M 7.5 % ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
29/3 M 6 %30/2 M 3.5 % ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
Typ R ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
… more than 250 different samples available immediately from our stock! Special samples
within 2 weeks + shipping (nominal charge)
EN 13986WO O D - B A S E D PA N E L S
EN 20354S O U N D A B S O R P T I O N
EN 13501-1FI R E C L A S S I F I C AT I O N
2022 EDITION
SUBJECT TO CHANGES
© TOPAKUSTIK
Printed in Switzerland on FSC-Mix Paper
MORE INNOVAT IVE
DES IGNS AT
W W W.TOPAKUST IK .COM
TOPAKUSTIK IS A BRAND OF:
TOPAKUSTIK AGOBSEESTRASSE 116078 LUNGERNSWITZERLAND
[email protected] T +41 41 679 73 73
DISTRIBUTED BY: