FIRE DEPARTMENT NOTES
1. FOR MAXIMUM OCCUPANT LOAD REFER TO LEGAL INFORMATION, OCCUPANT LOAD ON SHEET CS0.10. FINAL APPROVAL OF THE OCCUPANT LOAD IS CONTINGENT UPON FIELD INSPECTION AND OBTAINING A PERMIT TO OPERATE THAT PORTION OF THE PREMISES AS AN ASSEMBLY OCCUPANCY.
2. PLANS FOR PERMITS FOR AN AUTOMATIC EXTINGUISHING SYSTEM FOR KITCHEN HOODS WITH FRYERS. INSTALLATION SHALL BE SUBMITTED IN TRIPLICATE FOR APPROVAL TO THE FIRE DEPARTMENT.
3. INTERIOR WALL AND CEILING FINISHES FOR ASSEMBLY AREAS SHALL NOT EXCEED A FLAME
SPREAD CLASSIFICATION OF 200 (CLASS B).
4. ANY DECORATIONS USED SHALL BE NON-COMBUSTIBLE OR FLAME-RETARDANT TREATED IN
AN APPROVED MANNER (CURTAINS,DRAPES,SHADES HANGINGS,ETC.)5. PROVIDE DRAFT STOPS IN CONCEALED SPACES AS PER CURRENT CODE.
6. TWO(2)FIRE EXTINGUISHERS RATED AT 2A 10BC SHALL BE MOUNTED ON WALLS IN
ACCESSIBLE AND VISIBLE LOCATIONS. ONE IN THE KITCHEN/FOOD PREP. AREA, AND THE OTHER IN THE DINING AREA.
7. ONE PORTABLE FIRE EXTINGUISHER WHICH HAS A CLASSIFICATION OF NOT LESS THAN TYPE 'K’ SHALL BE PROVIDED FOR THE KITCHEN.
8. A MINIMUM OF ONE 2A10BC CLASSIFICATION FIRE EXTINGUISHER SHALL BE PROVIDED WITHIN SEVENTY-FIVE OF TRAVEL DISTANCE FOR EACH SIX THOUSAND SQUARE FEET OR PORTION THEREOF OF EACH FLOOR.
9. THE INSULATION IN THE FREEZER AND COOLER SHALL HAVE A FLAME SPREADING RATING NOT GREATER THAN 75 AND THE SMOKE-DEVELOPED RATING OF NOT MORE THAN 450. PROVIDE SPECIFICATIONS FOR THE INSULATION SHOWING THE FLAME SPREAD RATING AND SMOKE-DEVELOPED RATING.
10. PROVIDE ADDRESS NUMBERS AT LEAST EIGHT (8)INCHES HIGH, WHICH SHALL BE PLAINLY
VISIBLE FROM ROADWAY.11. EACH DINING AREA SHALL HAVE ONE WHEELCHAIR SEATING SPACE FOR EVERY TWENTY
SEATS. FOOD SERVICE AISLES SHALL BE NOT LESS THAN 36" CLR. WIDTH, WHILE A PREFERRED WIDTH OF 42",WHERE PASSAGE OF STOPPED WHEELCHAIRS BY PEDESTRIANS IS DESIRED. ACCESSIBLE SEATS ARE INTEGRATED WITH/ THE GENERAL SEATING TO ALLOW A REASONABLE SELECTION OF SEATING AREA AND TO AVOID HAVING ONE AREA SPECIFICALLY HIGHLIGHTED. TABLEWARE, DISHWARE, CONDIMENTS, FOOD BEVERAGE DISPLAY SHELVES AND DISPENSING DEVICES SHALL BE ACCESSIBLE. WHERE FIXED OR BUILT-IN TABLES, COUNTERS OR SEATS ARE PROVIDED FOR THE PUBLIC, AND IN GENERAL
EMPLOYEE AREAS, 5%(BUT NEVER LESS THAN ONE)MUST BE ACCESSIBLE.
12. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL OCCUPANT LOAD SIGN AS PER CURRENT CODE.
13. PLANS FOR ALL FIXED FIRE PROTECTION EQUIPMENT SHALL BE SUBMITTED TO THE FIRE
MARSHALL FOR APPROVAL PRIOR TO INSTALLATION.(HOOD)14. FOR LIGHTING FIXTURES AND EQUIPMENT SEE ELECT. PLANS - LIGHTING FIXTURE SCHEDULE15. FOR PLUMBING FIXTURES AND EQUIPMENT SEE PLUMBING PLANS - PLUMBING FIXTURE
SCHEDULE16. FOR MECHANICAL FIXTURES AND EQUIPMENT SEE MECHANICAL PLANS - MECHANICAL
FIXTURE SCHEDULE17. ALL GALVANIZED FINISHES TO RECEIVE ACID WASH.
REQUIRED SUBMITTALS
GENERAL CONTRACTOR SHALL PROVIDE THE FOLLOWING SUBMITTALS TO PROJECT OWNER FOR APPROVAL BEFORE PROCEEDING WITH WORK. CONTRACTOR SHALL ALSO PROVIDE ANY ADDITIONAL SUBMITTALS REQUIRED BY PROJECT OWNER, ARCHITECT, OR ENGINEER.A. PREFABRICATED ROOF TRUSSESB. DRIVE-THRU WINDOWC. STOREFRONT SYSTEM
OVERLAPPING AND CONFLICTING REQUIREMENTS:WHERE COMPLIANCE WITH 2 OR MORE INDUSTRY STANDARDS OR SETS OF REQUIREMENTS IS SPECIFIED, AND OVERLAPPING OF THOSE DIFFERENT STANDARDS ESTABLISHES DIFFERENT OR CONFLICTING MINIMUMS OR LEVELS OR REQUIREMENTS OF QUALITY, MOST STRINGENT REQUIREMENT (WHICH IS
GENERALLY RECOGNIZED TO BE ALSO MOST COSTLY)IS INTENDED AND WILL BE ENFORCED, REFER
APPARENTLY-EQUAL-BUT-DIFFERENT REQUIREMENTS, AND UNCERTAINTIES AS TO WHICH LEVEL OF QUALITY IS MORE STRINGENT, TO ARCHITECT/ ENGINEER FOR A DECISION BEFORE PROCEEDING.
MINIMUM QUALITY/QUANTITY:IN EVERY INSTANCE, QUALITY LEVEL OR QUANTITY SHOWN OR SPECIFIED IS INTENDED AS MINIMUM FOR THE WORK TO BE PERFORMED OR PROVIDED. EXCEPT AS OTHERWISE SPECIFICALLY INDICATED, ACTUAL
WORK MAY EITHER COMPLY EXACTLY WITH THAT MINIMUM (WITHIN SPECIFIED TOLERANCES), OR MAY
EXCEED MINIMUM WITHIN REASONABLE LIMITS. IN COMPLYING WITH REQUIREMENTS,INDICATED NUMERIC VALUES ARE EITHER MINIMUMS OR MAXIMUMS AS NOTED OR AS APPROPRIATE FOR CONTEXT OF REQUIREMENTS. REFER INSTANCES OF UNCERTAINTY TO ARCHITECT/ ENGINEER FOR DECISION BEFORE PROCEEDING.
NOTES TO CONTRACTOR
1. WHERE CONTRACT DOCUMENTS (DRAWINGS AND SPECIFICATIONS)ARE INCOMPLETE,
AMBIGUOUS OR CONTAIN CONFLICTING INSTRUCTIONS, DO NOT PROCEED UNTIL RECEIVING CLARIFICATION FROM THE ARCHITECT OR OWNER IN WRITING.
2. PROVIDE PROTECTION OF PEDESTRIANS AND PUBLIC DURING CONSTRUCTION. PROVIDE BARRICADES AND CANOPIES AS REQUIRED FOR PUBLIC SAFETY. PROVIDE MINIMUM 6’-0’’ AWAY FROM CONSTRUCTION OR OTHER APPROVED MEANS OF PROTECTION AS ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION.
SIGNAGEALL SIGNAGE AND SIGN DETAILS ARE UNDER SEPARATE DRAWINGS AND PERMIT BY OWNER'S VENDOR. ON SITE DELIVERY AND INSTALLATION TO BE SCHEDULED BY GENERAL CONTRACTOR. GC TO
COORDINATE ANY POWER AND FOOTING REQUIREMENTS PRIOR TO COMMENCING WORK.
SEPARATE SUBMITTALSA. SIGNAGEB. IRRIGATIONC. FENCE (WHEN REQUIRED)
INFORMATION:ALL SPECIAL INSPECTIONS WILL BE THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. INSPECTIONAL SERVICES DIVISION (ISD) WILL NEED COPIES OF ALL 3RD PARTY SPECIAL INSPECTIONS AND ALSO A SUMMARY OF ALL SPECIAL INSPECTIONS. PLEASE MAKE CERTAIN THE COPIES OF THE 3RD PARTY INSPECTIONS ARE AVAILABLE FOR ISD FIELD INSPECTORS TO PICK-UP WHEN MAKING THEIR NORMAL INSPECTIONS.
A.F.F.ADH.ADJ.A/CALUM.TH.&L/APPROX.@
B./BOT.BLK./BLKING.BD.
CAB.CEM.CLG.C.L./CCLR.CERM.[ ]COL.CONC.CTR.C.M.U.CONST.CONT.CONTR.
D.DEMODIA/φDIF.DR.DN.DWG.
EA.ELEC.EQUIP.EXIST./(E)E.J.EXT./EXTR.
FIN.FIN. FLR./F.F.F.P.F.R.
ABOVE FINISH FLOORADHEREADJACENT/ADJUSTABLEAIR CONDITIONING/ERALUMINUMTHRESHOLDANDANGLEAPPROXIMATEAT
BOTTOMBLOCK/BLOCKINGBOARD
CABINETCEMENTCEILINGCENTER LINECLEARCERAMICCHANNELCOLUMNCONCRETECOUNTERCONCRETE MASONRY UNITCONSTRUCTIONCONTINUOUSCONTRACTOR
DEPTHDEMOLITIONDIAMETERDIFFUSER/DIFFERENTDOORDOWNDRAWING
EACHELECTRIC/ELECTRICALEQUIPMENTEXISTINGEXPANSION JOINTEXTERIOR
FINISH/FINISHESFINISH FLOORFIRE PROOFFIRE RESISTANT
F.S.E.F.S.E.C.FIXT.FLR.FLUOR.FRAM'G.FR.FURN.
GALV.GA.G.C.GYP.GYP.BD.
HDW.HVACHT./H./HGT.H.C.HR.
INCL.INSUL.INT./INTR.
JAN.JT.
LAM.LTG.
MACH.MFGR.MAS.MAX.MECH.MTL.MIN.
N.NOM.N.I.C.#
O.O.F.C.I.O.C.OPP.
FOOD SERVICE EQUIPMENTFOOD SERVICE EQUIPMENT CONTRACTORFIXTUREFLOORFLUORESCENTFRAMINGFROMFURNISH/FURNISHING
GALVANIZEDGAGE/GAUGEGENERAL CONTRACTORGYPSUM BOARD
HARDWAREHEATING,VENTILATING & AIR CONDITIONINGHEIGHTHOLLOW CREHOUR
INCLUDING/INCLUSIVEINSULATION/INSULATEINTERIOR
JANITORJOINT
LAMINATELIGHTING
MACHINEMANUFACTURERMASONRYMAXIMUMMECHANICALMETALMINIMUM
NETNOMINALNOT IN CONTRACTNUMBER
OWNEROWNER FURN., G.C. INSTALLEDON CENTEROPPOSITE
P./PT.PLAS. LAM./P.L.PL.PLYWD.POL.
QTY.Q.T.
R./RAD.R.A./ R /ARECPREINF.REQ'D.RM.R.O.
S.A./ S/SSCHEDS.SK.S.S./ S/S / S.ST.SHT.SIM.S.C.SK.SPEC.STL.STO./STOR.STRUCT.SUSP.
T.TEMP.T.V.TH.T,F.T.F.&P.TYP.
VAR.
W.W.R.W.S.W/WD.
PAINT/POINTPLASTIC LAMINATEPLATEPLYWOODPOLISHED
QUANTITYQUARRY TILE
RADIUSRETURN AIRRECEPTACLEREINFORCEDREQUIREDROOMROUGH OPENING
SUPPLY AIRSCHEDULESERVICE SINKSTAINLESS STEELSHEETSIMILARSOLID CORESINKSPECIFICATIONSTEELSTORAGESTRUCTURE/STRUCTURALSUSPENDED
TOP/TILETEMPORARYTELEVISIONTHICK/THRESHOLDTAPE, FLOAT TAPE,FLOAT & PAINTTYPICAL
VARIES
WIDTHWATER RESISTANTWEATHER STRIPWITHWOOD
ADD MAP
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
CS0.01
XXXXX
BID & PERMIT
XX-XX-XX
COVER SHEET
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
GENERAL BUILDING NOTES CONSULTANT/ CONTACTS VICINITY MAP
SHEET INDEX
SHEET LIST - ARCHITECTURE
A0.10 SITE PLAN
A0.20 SITE DETAILS
A1.00 FLOOR PLAN
A1.40 ROOF PLAN
A1.41 ROOF DETAILS
A1.50 EXTERIOR ELEVATIONS
A1.51 EXTERIOR ELEVATIONS
A1.60 SECTIONS
A1.61 SECTION & WALL SECTIONS
A3.10 ENLARGED RR PLAN & DETAILS
A4.10 REFLECTED CEILING PLAN
A4.11 REFLECTIVE CEILING PLAN - DETAILS
A5.10 FINISH FLOOR PLAN & FINISH DETAILS
A5.60 ELEVATIONS & DETAILS - INTERIOR
A5.61 ELEVATIONS & DETAILS - INTERIOR
A5.62 ELEVATIONS & DETAILS - INTERIOR
A5.63 ELEVATIONS & DETAILS - INTERIOR
A6.00 FINISH SCHEDULES
A6.01 WINDOW & DOOR SCHEDULES
A7.00 BACKING PLAN
PROJECT LOCATION
JOB NAME:
CLIENT:
JOB LOCATION: ADDRESS, CITY, STATE, ZIP CODE
EL POLLO LOCO STORE NUMBER:
EL POLLO LOCO 2995 PROTO
XXXX
ABBREVIATIONS CONCEPTUAL DESIGN
SCOPE OF WORKNEW ONE STORY BUILDING RESTAURANT, WITH DRIVE-THRU, AWNINGS AND DRIVE-THRU. REQUIRED PARKING AND ACCESS TO ADJACENT TENANTS AND PUBLIC WALKWAY.
OWNEREL POLLO LOCO3535 HARBOR BLVD.,SUITE 100COSTA MESA, CA 92626(714) 599.5000
CIVIL ENGINEERSUPDATE
KITCHEN DESIGNERTRIMARK2801 MCGAW AVENUE, SUITE BIRVINE, CA 92614(949) 398.8683EMAIL: [email protected]
ARCHITECTSTK ARCHITECTS106 W 11TH STREET, SUITE 1900KANSAS CITY, MO 64105TEL: (816) 842-7552FAX: (816) 842-1302CONTACT: ERIN GARRISONEMAIL: [email protected]
STRUCTURAL ENGINEERTK ARCHITECTS106 W 11TH STREET, SUITE 1900KANSAS CITY, MO 64105TEL: (816) 842-7552FAX: (816) 842-1302CONTACT: DAVID TAYLOREMAIL:[email protected]
MECHANICAL / PLUMBING / ELECTRICAL ENGINEERTK ARCHITECTS106 W 11TH STREET, SUITE 1900KANSAS CITY, MO 64105TEL: (816) 842-7552FAX: (816) 842-1302CONTACT: BRAD REYNOLDSEMAIL: [email protected]
SHEET LIST - CIVIL
C1.00 CIVIL COVER SHEET
C1.10 GENERAL NOTES
C2.00 EROSION CONTROL PLAN
C2.10 EROSION CONTROL DETAILS
C3.00 DEMOLITION PLAN
C4.00 DIMENSION CONTROL & PAVING PLAN
C5.00 GRADING PLAN
C6.00 EXISTING DRAINAGE AREA MAP
C7.00 PROPOSED DRAINAGE AREA MAP
C8.00 UTILITY PLAN
C9.00 CONSTRUCTION DETAILS
SHEET LIST - LANDSCAPE
L1.00 LANDSCAPE PLAN
SHEET LIST - STRUCTURAL
S1.00 GENERAL NOTES & ABBREVIATIONS
S2.00 TYPICAL DETAILS
S3.00 TYPICAL DETAILS
S4.00 FOUNDATION PLAN
S5.00 ROOF FRAMING PLAN
S6.00 FOUNDATION DETAILS
S7.00 ROOF FRAMING DETAILS
S8.00 ROOF FRAMING DETAILS, ISOMETRIC VIEW
SHEET LIST - PLUMBING
P0.10 SITE PLAN - PLUMBING
P1.00 PLUMBING SYMBOLS AND SCHEDULES
P1.10 FLOOR PLAN - LOWER PLUMBING
P1.20 FLOOR PLAN - UPPER PLUMING
P1.30 FLOOR PLAN - GAS PLUMBING
P1.40 ROOF PLAN - PLUMBING
P1.70 DOMESTIC WATER RISER DIAGRAM
P1.80 WASTE & VENT RISER DIAGRAM
P1.90 GAS RISER DIAGRAM
SHEET LIST - MECHANICAL
M1.00 SCHEDULES AND REQUIREMENTS
M1.10 FLOOR PLAN - MECHANICAL
M1.20 ROOF PLAN - MECHANICAL
M1.30 MECHANICAL DETAILS
M1.40 HOOD DETAILS
M1.41 HOOD DETAILS
M1.42 HOOD DETAILS
M1.43 HOOD DETAILS
M1.44 HOOD DETAILS
M1.45 HOOD DETAILS
SHEET LIST - ELECTRICAL
E0.10 SITE ELECTRICAL PLAN
E1.00 NOTES AND SYMBOL LIST
E1.10 LIGHTING PLAN
E1.20 POWER PLAN
E1.40 ROOF POWER PLAN
E1.50 SINGLE LINE DIAGRAM
E1.70 ELEVATIONS AND DATA PLAN
SHEET LIST - KITCHEN
K1 EQUIPMENT FLOOR PLAN
K2 EQUIPMENT SCHEDULE
K3 PLUMBING ROUGH-IN PLAN
K4 ELECTRICAL ROUGH-IN PLAN
K5 EQUIPMENT ELEVATIONS
K6 EQUIPMENT ELEVATIONS
SHEET LIST - COVER SHEET
CS0.01 COVER SHEET
CS0.02 RESPONSIBILITY MATRIX
CS0.10 CODE INFORMATION
REVISIONS
NO. DATE DESCRIPTION
UPDATE
ITEMPROVIDE INSTALL COMMENTS
DESCRIPTION
1 HVAC RTU'S, MUA UNIT AND CURBS
2 HOODS, HOOD FIRE SUPPRESSION SYSTEMS AND HOOD EXHAUST FAN/CURB PACKAGE
3 MUSIC SYSTEM
4 CCTV SYSTEM
5 SECURITY SYSTEM
6 DRIVE-THRU LOOPS
7 DRIVE-THRU TIMER/HEADSET SYSTEM
8
LIGHTING FIXTURE PACKAGE (EXCLUDING SITE LIGHTING)9
LIGHTING CONTROLS
10
METAL CANOPIES AND LIGHTING
11
CO2 SYSTEM
12
SODA SYSTEMS (AND WATER FILTER)
13
STAINLESS STEEL FIXTURES AND COUNTERTOPS
14
KITCHEN EQUIPMENT PACKAGE AND KITCHEN SINKS
15
KITCHEN FAUCETS
16
DRIVE-THRU EQUIPMENT PACKAGE
17
RESTROOM MIRROR
18
QUARRY TILE AND CERAMIC FLOOR & WALL TILE AND BASE
19
FACE BRICK (INTERIOR & EXTERIOR)
20
PAINTED TILE PATTERN PANELS (EXTERIOR ONLY)
21
22
WINDOW SHADES23
INTERIOR ARTWORK AND MENU BOARD (NOT INCLUDING OCCUPANCY SIGN)24
EXTERIOR GRAPHIC MARQUEE PANELS25
MILLWORK, SETTEES, TABLES, DIVIDER WALLS (WOOD, METAL & GLASS) PACKAGE26
CHAIRS27
LOCKS AND CORES28
BUILDING SIGNAGE AND DRIVE-THRU SIGNAGE29
CHEMICAL AND HAND SOAP30
OFFICE AND POS SAFES
31
IT EQUIPMENT AND POS EQUIPMENT
32
PATIO FURNITURE AND UMBRELLAS
32
HOOD COMMISSIONING
OWNER GC
GC TO UNPACK AND PLACE CHAIRS AND TABLES
FOOTINGS AND POWER BY GC
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
GC
GC
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
OWNER
GC
GC
GC
GC
GC
GC
GC
GC
GC
GC
GC
GC
VENDOR
VENDOR
VENDOR
VENDOR
VENDOR
VENDOR
VENDOR
VENDOR
VENDOR
VENDOR
VENDOR
VENDOR
VENDOR
VENDOR
VENDOR
VENDOR/GC
VENDOR
OWNER
VENDOR
RESPONSIBILITY MATRIX
33
SITE LIGHTING GC GC
GC TO INSTALL IN RESTROOMS
GC TO COORDINATE AFTER ALL EQUIPMENT IS ON-LINE AND PRIOR TO FINAL AIR BALANCE
INCLUDES GAS SOLENOID
INCLUDES LOW-VOLTAGE RE-WIRE
INCLUDES LOW-VOLTAGE RE-WIRE
WALK-IN COOLER OWNER VENDOR
PAPER TOWEL DISPENSERS OWNER GC
LIGHTING IS PRE-INSTALLED
INCLUDES HORCHATA
EXCLUDES MOP SINK
34
POINT OF SALE EQUIPMENT INCLUDES LOW-VOLTAGE PRE-WIREOWNER VENDOR
35
HVAC TEST AND BALANCE OWNER OWNER GC TO COORDINATE; 2 WEEKS NOTICE REQUIRED36
NOTE: GC TO REFER TO OWNER-PROVIDED CONTACT LIST FOR SPECIFIC VENDOR CONTACTS AND DETAILS.
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
TKa r c h i t e c t s
I
®™N T E R N A T I O N A L
____________________________
PROJECT #
SHEET NUMBER
CS0.02
XXXXX
BID & PERMIT
XX-XX-XX
RESPONSIBILITYMATRIX
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
REVISIONS
NO. DATE DESCRIPTION
W/H
S2442
F
S2424
S2424
S1424
S2448
S2448
S2448
2436
G
LEGEND
EGRESS PATH
F.E.
F.E.C.
FIRE EXTINGUISHER (WALL BRACKET MOUNT)
FIRE EXTINGUISHER AND CABINET
EGRESS WIDTH PER OCC. PER TABLE FOR SPRINKLED BUILDING. 0.2" STAIRS 0.3" ELSE WHERE.
28 OCCUPANT CONVERGENCE
2' -
6"
4' - 0"
ACCESSIBLE SEATING AREA
8"38
(72")
EGRESS WIDTH PER OCC. PER TABLE FOR NON-SPRINKLED BUILDING.0.2" DOORS
POPULATION EXITING MIN. REQ'D EGRESS CLR. WIDTH PROVIDED
DINING
62
6"31
(34")
31
9"44
(72")
1"7
(34")
5
15
31 44
102' - 4"
1"3
(34")
006
006
004009
006
102' - 10" 102' - 10"
102' - 4"
102' - 4"
004
004
SALSA BAR
0
CUSTOMER PICK-UP
12
DRIVE-THRU
1
OFFICE
1
SERVING
3
WORK AREA
0
STORAGE
1
MENS
111WOMENS
110
COOLER
107
WATER HEATER
114
KITCHEN
4
7
002003
002
005
000 001
003
006
009
006
006
006
006
006
006
136
003
THE INTERNATIONAL SYMBOL OF ACCESSIBILITY ISREQUIRED ON:
• PARKING SPACES DESIGNATED AS RESERVED FOR INDIVIDUALS WITHDISABILITIES
• ACCESSIBLE ENTRANCES (INACCESSIBLE ENTRANCES SHALL HAVEDIRECTIONAL SIGNAGE TO INDICATE THE ROUTE TO THE NEARESTACCESSIBLE ENTRANCE)
• ACCESSIBLE TOILET AND BATHING FACILITIES
THE INTERNATIONAL SYMBOL OF ACCESSIBILITY
DISPLAY CONDITIONS
PLACEMENT/ LOCATIONPERMANENT SIGNAGE TO BE INSTALLED ON THEWALL ADJACENT TO THE LATCH SIDE OF THE DOOR.MOUNTING LOCATION MUST ALLOW A PERSON TOAPPROACH WITHOUT ENCOUNTERING PROTRUDING OBJECTSOR STANDING WITHIN THE SWING PATH OF THE DOOR.
LITERARY BRAILLE STANDARD DIMENSIONS:
DOT DIAMETER .059 IN.INTER-DOT SPACING .090 IN.HORIZONTAL SEPARATION BETWEEN CELLS .241 IN.VERTICAL SEPARATION BETWEEN CELLS .395 IN.
FINISH & CONTRAST:CHARACTERS, SYMBOLS AND THEIR BACKGROUND SHALLHAVE A NON-GLARE FINISH. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND, EITHER LIGHTCHARACTERS ON A DARK BACKGROUND OR DARKCHARACTERS ON A LIGHT BACKGROUND.
LETTERS AND NUMERALS SHALL BE RAISED 1/32", UPPERCASE, SANS SERIF TYPE AND SHALL BE ACCOMPANIEDWITH GRADE II BRAILLE. RAISED CHARACTERS SHALL BEAT LEAST 5/8" HIGH, BUT NO HIGHER THAN 2"
CORRESPONDING GRADE II BRAILLE
EXIT
4' -
10" A
.F.F
MIN
.
TO H
IGH
EST
LIN
E O
F R
AISE
D L
ETTE
RS
5' -
0" A
.F.F
MAX
.
EXIT
48" MIN.
30" M
IN.
NOTE: UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCE COMPLYING WITH 306.
11" MIN.
30" M
IN.
25" MAX.ELEVATION PLAN
NOTE: SPACE UNDER AN ELEMENT BETWEEN 9 INCHES AND 27 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL BE CONSIDERED KNEE CLEARANCE AND SHALL COMPLY WITH 306.3.
MINIMUM REQUIRED DEPTH: WHERE KNEE CLEARANCE IS REQUIRED UNDER AN ELEMENT AS PART OF A CLEAR FLOOR SPACE, THE KNEE CLEARANCE SHALL BE 11 INCHES DEEP MINIMUM AT 9 INCHES ABOVE THE FINISH FLOOR OR GROUND, AND 8 INCHES DEEP MINIMUM AT 27 INCHES ABOVE THE FINISH FLOOR OR GROUND.
WIDTH: KNEE CLEARANCE SHALL BE 30 INCHES WIDE MINIMUM.
9" M
IN.
8" MIN.
27" M
IN.
9"
MAX.
6"
30" M
IN.
17" - 25"
ELEVATION
PLAN
NOTE: SPACE UNDER AN ELEMENT BETWEEN THE FINISH FLOOR OR GROUND AND 9 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL BE CONSIDERED TOE CLEARANCE AND SHALL COMPLY WITH 306.2.
MINIMUM REQUIRED DEPTH: WHERE TOE CLEARANCE IS REQUIRED AT AN ELEMENT AS PART OF A CLEAR FLOOR SPACE, THE TOE CLEARANCE SHALL EXTEND 17 INCHES MINIMUM UNDER THE ELEMENT.
WIDTH: TOE CLEARANCE SHALL BE 30 INCHES WIDE MINIMUM.
OCCUPANT LOADLOBBY 140
TOTAL BUILDING1126
MEN WOMEN
GENERAL NOTES:1. ALL SIGNS ARE TO BE PLASTIC WITH EMBOSSED SYMBOLS AND TEXT2. SIGNS ARE TO BE VINYL TAPE MOUNTED WHERE POSSIBLE3. SIGN BACKGROUND IS TO MATCH COLOR OF WALL IF PERMITTED BY CODE AND LOCAL OFFICIALS. ALL BRAILLE TO CONFORM WITH ADA AND CODE REQUIREMENTS.4. VERIFY SIGN SIZE, COLORS, GRAPHICS, AND LOCATIONS WITH LOCAL OFFICIALS. 5. ACTUAL SIZES MAY VARY FROM THOSE SHOWN. NOTIFY THE ARCHITECT AND OWNER OF ANY CHANGES BEFORE PRODUCTION AND INSTALLATION.6. LOCATIONS OF SIGNS CALLED OUT ON CODE PLAN. 7. ADDITIONAL SIGNS MAY BE REQUIRED. SIGNAGE TO BE VERIFIED WITH OWNER8. ALL CODE SIGNAGE TO BE PROVIDED AND INSTALLED BY G.C.
8"
9"
8"
9"
6 1/2"
3 3/
8"
1/2" LETTERS
1" LETTERS1" LETTERS
S2
FAMILYRESTROOM
8"
9"
1" LETTERS
S1 S3
S4 S6
27x42
2' -
6"
48" MIN.
30" M
IN.
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
CS0.10
XXXXX
BID & PERMIT
XX-XX-XX
CODEINFORMATION
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
APPLICABLE CODES
OCCUPANCY GROUP:
OCCUPANCY TYPE : A2CONSTRUCTION TYPE : VB
ALLOWABLE HEIGHTS: 50'-0"
OCCUPANCY SUMMARY
BUILDING SQUARE FOOTAGE: 2,995 SQ FT
ALLOWABLE AREAS: 6,000 SQ FT
FIRE PROTECTION:
EGRESS:
PLUMBING REQUIREMENTS:
CODE
BUILDING CODE AND RELATED EXCERPTS OF THE MUNICIPAL 2012 ELECTRICAL CODE NATIONAL ELECTRICAL CODE 2012 FUEL/GAS CODE INTERNATIONAL FUEL GAS CODE 2012 BUILDING CODE INTERNATIONAL BUILDING CODE 2012 LIFE SAFETY CODE NFPA 101 - LIFE SAFETY CODE 2012 MECHANICAL CODE INTERNATIONAL MECHANICAL CODE 2012 FIRE CODE INTERNATIONAL FIRE CODE2012 PLUMBING CODE INTERNATIONAL PLUMBING CODE2012 ENERGY CODE INTERNATIONAL ENERGY CONSERVATION CODE2012 ADA CODE ADA STANDARDS FOR ACCESSIBLE DESIGN
1/4" = 1'-0"1
CODE PLAN
LEGAL JURISDICTION:
DINING AREA
SEATING COUNT (BASED ON TABLE/CHAIRS PROVIDED) 960 SF = 62 OCC.
SERVICE (BASED ON # OF EMPLOYEE) FIXED # OF EMPLOYEE = 3 OCC.CUSTOMER PICK UP 60 SF/5 = 12 OCC.KITCHEN AREA 829 SF/200 = 4 OCC.
STORAGE AREA (DRY & COOLER) 286 SF/300 = 1 OCC.
OFFICE 40 SF/100 = 1 OCC.
ACCESSORY USE (RESTROOMS, CIRCULATION, ETC.) 835 SF = 0 OCC.
TOTALS*73 OCC. 83 OCC.
*TOTAL SQUARE FOOTAGE INCLUDES ± 86 SF OF INTERIOR WALL THICKNESS
EXITS REQUIREMENTS: > 50 OCCUPANTS 2 EXITS REQ'D / 3 PROVIDED
TOTAL OCCUPANT LOAD/2 = 83/2 = 41.5MAIN EXIT WIDTH REQUIRED = 41.5 X 0.2= 8.3"
TOTAL EGRESS WIDTH PROVIDED: 176'', THEREFORE COMPLIES WITH CODES SECTION 1028.2
BASED ON TOTAL OCCUPANCY LOAD = 83 TOTAL OCCUPANTS
MINIMUM PLUMBING FIXTURES FOR IBC 2902.1:1 PER 75 MALES = 1 REQ'D/ 1 WATER CLOSET & 1 URINAL PROVIDED1 PER 75 FEMALES = 2 REQ'D / 2 WATER CLOSET PROVIDED1 LAVATORY PER 200 REQ'D / 1 FOR EACH SEX PROVIDED1 SERVICE SINK REQ. / 1 SERVICES SINK PROVIDEDDRINKING FOUNTAIN NOT REQ'D DUE TO RESTAURANT USE
FIRE SPRINKLERS: NO FIRE SPRINKLERS REQUIRED
FIRE ALARM: NO FIRE ALARM REQUIRED
N.T.S.3
ACCESSIBLE ENTRANCE SIGN
1/4" = 1'-0"2
TACTILE SIGN
PROPERLY EXISTING THE NEW BUILDING DURING AN EMERGENCY BASED ON THE 2012 IBC REGARDING "EGRESS". DOORS AT EXIT PASSAGEWAYS, EXIT DISCHARGE, AND EXIT STAIRWAYS SHALL BE IDENTIFIED BY TACTILE SIGNS COMPLYING WITH 703.1, 703.2, AND 703.5. IF PROVIDED, MUST FULLY COMPLY. PLEASE VERIFY COMPLIANCE ACCORDINGLY PRIOR TO THE REQUIRED ON-SITE ACCESSIBILITY/ USABILITY INSPECTION.
EXCEPTIONS:A. WHERE MEANS OF EGRESS ARE PERMITTED BY LOCAL BUILDING OR LIFE SAFETY CODES TO SHARE A COMMON PATH OF EGRESS TRAVEL, ACCESSIBLE MEANS OF EGRESS SHALL BE PERMITTED TO SHARE A COMMON PATH OF EGRESS TRAVEL.
WHERE FIRE ALARM SYSTEMS PROVIDE AUDIBLE ALARM COVERAGE, ALARMS SHALL COMPLY WITH 215.
KEYNOTE LEGEND - NEW
000 TACTILE EXIT SIGN AT 48" A.F.F. TO READ "EXIT" IN1" UPPERCASE SAN SERIF LETTERS RAISED 1/32"AND ACCOMPANIED BY GRADE 2 BRAILLE. RE:2/CS0.10.
001 PROVIDE OCCUPANCY LOAD SIGN AT ENTRYDOORS. RE: 4/CS0.10.
002 PROVIDE ADA COMPLIANT SIGNAGE AT RESTROOMDOORS. RE: 4/CS0.10.
003 PROVIDE INTERNATIONAL SYMBOL OFACCESSIBILITY. RE: 3/CS0.10
004 ACCESSIBLE SEATING, 30" X48" OF CLEAR FLOORSPACE.
005 ACCESSIBLE COUNTER AREA, 30" X48" OF CLEARFLOOR SPACE.
006 ACCESSIBLE 30" X 48" CLEAR FLOOR SPACE.
009 AIR CURTAIN TO BE DOOR ACTIVATED.
136 ROOF LADDER.
3/4" = 1'-0"8
CLEAR FLOOR
3/4" = 1'-0"6
KNEE CLEARANCE
3/4" = 1'-0"5
TOE CLEARANCE
CITY OF XXXXXXXX, XXXXXXXX COUNTY
3" = 1'-0"4
CODE SIGNAGE DETAILS
3/4" = 1'-0"7
CLEARANCE AT TABLE
REVISIONS
NO. DATE DESCRIPTION
UPDATE
UPDATE
UPDATE
WHEN CA
UPDATE
WHEN CA
A-0
03
9
7
8 8 8
SCR
EEN
FO
RPA
TIO
LOT
LIN
E
LOT
LIN
E
EXIS
TIN
GW
ALK
55
55
5
EXIS
TIN
G P
ARKI
NG
AN
DIS
LAN
DS
TO R
EMAI
N
EXIS
TIN
G P
ARKI
NG
AN
DIS
LAN
DS
TO R
EMAI
N
AREA
OF
PAD
TO
BE M
OD
IFIE
D
TRASH
PATI
O97
4 SF
9
EXIT
ON
LY
DRIVE
THRU24'
20'
TOTAL PARKING = 30
A0.20
1
611
611
614
TRASH
EXIT
O
NLY
UPDATE BACKGROUND
PER CIVIL
617
TYP
TYP
8' - 6".
TYP
9' - 0"
TYP
612
601
603
616
TYP
606
TYP
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A0.10
XXXXX
BID & PERMIT
XX-XX-XX
SITE PLAN
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1. PER THE SUBMITTED CONSTRUCTION CONTRACT DOCUMENT WORKING DRAWINGS SHEETS C-1, C-2 & C-5, C-6, C-7, C-8, THE FEDERAL GOVERNMENT THROUGH THE 2010 A.D.A. AND THE STATE OF TEXAS THROUGH THIS 2012 T.A.S. HAVE GONE ON RECORD INDICATING THAT ALL OF THE SHARED ACCESS AISLE AT ACCESSIBLE PARKING SPACES MUST BE 5'-0" WIDE - EVEN FOR VAN SPACES (MUST STILL ALLOW A MINIMUM TOTAL OF 16'-0" VEHICLE FRONT - APPROACH WIDTH - WITH AN 11'-0" MINIMUM WIDE PARKING SPACE AND A 5'-0" WIDE ACCESS AISLE) -BECAUSE PEOPLE ARE EITHER PARKING ON-PURPOSE OR BY MISTAKE WITHIN 8'-0" WIDE ACCESS AISLES. NOTE: ONLY THROUGH THE APPLICATION OF THE EXCEPTION PER SECTION 502.2 IS AN 8'-0" WIDE ACCESS AISLE ALLOWED AT A VAN SPACE. PLEASE VERIFY COMPLIANCE ACCORDINGLY PRIOR TO THE REQUIRED ON-SITE ACCESSIBILITY/ USABILITY INSPECTION.
2. WHERE PARKING SPACES ARE PROVIDED, PARKING SPACES SHALL BE PROVIDED IN ACCORDANCE WITH 208.EXCEPTION: PARKING SPACES USED EXCLUSIVELY FOR BUSES, TRUCKS, OTHER DELIVERY VEHICLES, LAW ENFORCEMENT VEHICLES, OR VEHICULAR IMPOUND SHALL NOT BE REQUIRED TO COMPLY WITH 208 PROVIDED THAT LOTS ACCESSED BY THE PUBLIC ARE PROVIDED WITH A PASSENGER LOADING WITH 503.
3. CAR AND VAN PARKING SPACES SHALL COMPLY WITH 502. WHERE PARKING SPACES ARE MARKED WITH LINES, WIDTH MEASUREMENTS OF PARKING SPACES AND ACCESS AISLES SHALL BE MADE FROM THE CENTERLINE OF THE MARKINGS. EXCEPTION: WHERE PARKING SPACES OR ACCESS AISLES ARE NOT ADJACENT TO ANOTHER PARKING SPACE OR ACCESS AISLE, MEASUREMENTS SHALL BE PERMITTED TO INCLUDE THE FULL WIDTH OF THE LINE DEFINING THE PARKING SPACE OR ACCESS AISLE.
4. ACCESS AISLES SERVING PARKING SPACES SHALL COMPLY WITH 502.3. ACCESS AISLES ADJOIN AN ACCESSIBLE ROUTE. TWO PARKING SPACES SHALL BE PERMITTED TO SHARE A COMMON ACCESS AISLE. ACCESS AISLES SERVING CAR AND VAN PARKING SPACES SHALL BE 60" WIDE MINIMUM.
PARKING SPACES NOTE
3/32" = 1'-0"1
SITE PLAN
PARKING CALCULATION
BUILDING SQUARE FOOTAGE 2,995 SF AREA
PARKING REQUIREMENT REQUIRED PROVIDED1 PER 100 SQ FT OF FLOOR 30 SPACES 30 SPACES
HANDICAP PARKING REQUIREMENT REQUIRED PROVIDED2 PER 26 - 50 TOTAL SPACES IN LOT 2 SPACES 2 SPACES
KEYNOTE LEGEND - NEW
600 MAXIMUM HEIGHT CLEARANCE POLE BEFORE THE 8THCAR. PROVIDED BY OWNER VENDOR. CLEARANCE BARFOOTING DETAIL, RE: A1.01 BY G.C.
601 DRIVE-THRU DIRECTIONAL SIGN PROVIDED BY VENDOR.G.C. TO INSTALL SIGN FOOTING AND ANCHOR BOLTSPER SIGN VENDOR CUT SHEETS.
602 PRE-MENU BOARD FOR THE 6TH CAR. PROVIDE BY SIGNVENDOR. FOR PRE-MENU BOARD FOOTING DETAIL, RE:A1.01 BY G.C.
603 MENU BOARD FOR THE 5TH CAR PROVIDED ANDINSTALLED BY OWNER'S SIGN VENDOR. FOR MENUBOARD FOOTING DETAIL, RE: A1.01 BY G.C.
606 SIGN SHOWS "THANK YOU" ON ONE SIDE AND "WRONGWAY" ON THE OTHER SIDE. RE: SIGN VENDORSPREADSHEETS.
610 ACCESSIBLE SPACE TO BE 9'-0" X 18'-0"
611 LANDSCAPE. RE: L DRAWING.
612 TRAVEL DISTANCE IS 12.5'
614 DRIVE-THRU CANOPY BY VENDOR.
616 ADA ACCESS STRIPING.
617 WHEELSTOPS.
618 GUARD POST BOLLARD.
REVISIONS
NO. DATE DESCRIPTION
UPDATE
UPDATE:DIMENSION ALL SIGN FOOTINGS FROM
SURVEY POINT
ADD MONUMENT SIGN IF APPLICABLE
COORDINATE W/ CIVIL AND SIGN SHOP DRAWINGS
NOTES
1. PROVIDE CAGE AND BOLLARDS AS NEEDED WHEREVER A BACKFLOW DEVICE IS LOCATED ABOVE GROUND WHERE VEHICLE TRAFFIC OCCURS NEARBY.
2. GC TO CONFIRM LOCATION OF MONUMENTOR POLE SIGN WITH SIGN VENDOR AND OWNER. LOCATION ON THIS PLAN IS FOR REFERENCE ONLY.
SOLID GROUT ALL CORES
#5 BARS @48" O.C. CONT. THRU WALL & INTO FTG. W/ 3" HOOK
8"x8"x16" CMU WALL W/ DUR-O-WALL EVERY SECOND COURSE. STUCCO & PAINT TO MATCH BUILDING
#5 HORIZ. BAR @ MID-HEIGHT; TIE TO #5 VERT. BAR (TYP)
6" P.C.C. SLAB ON 6" AGG. BASE W/ #4 CONT. E.W. @ 4'-0" O.C.
#5 HORIZ. BAR @ TOP (TYP) TIE TO #5 VERT. BARS
NOTES:1. STUCCO MAY BE OMITTED IF CMU IS SPLIT FACE BLOCK, SLUMP STONE BLOCK OR FLUTED BLOCK
2. FOOTINGS SHALL EXTEND 18" MIN. BELOW ADJACENT FINISH GRADE/SURFACE OR BELOW FROST DEPTHS PER LOCAL CODES. SEE SOILS REPORT FOR ANY ADDITIONAL DESIGN CRITERIA
#5 BARS CONT. TOP & BOTTOM
PAVEMENT SURFACE AS SPECIFIED
6"1'
- 6"
1' - 4" CLR
.3"
INTERIOR CURB SEALED TO BLOCK WALL
CONCRETE SLAB & CURB TO BE SEALED PER FINISH SCHEDULE
1"x18GA. METAL DECK
3"x4"x1/4" METAL ANGLE FRAME 4 SIDES EA. GATE
2 PAIR McKINNEY T4B3781 HINGES EA. GATE WELDED TO GATE & POST
GROUT SOLID W/ CONCRETE
METAL SCREED
STUCCO ON METAL LATH
#5 VERT. BAR @48" O.C.
#5 HORIZ. BARS @ TOP & MID-HEIGHT
8"x8"x16" CMU WALL
38/" DIA. A.B. 14"x2" @ 16" O.C. VERT.; BOLT TO T.S. W/ ACORN NUT ON OUTSIDE
5"x5"x1/4" T.S. W/ 5"x5"x1/4" CAP PLATE EMBEDDED 12" INTO FOOTING
NOTES:
1. LOCATION SHALL BE APPROVED BY THE PUBLIC WORKS DEPARTMENT.2. AREAS SHALL BE ACCESSIBLE FOR DELIVERY AND COLLECTION.3. GATES SHALL BE CORRUGATED METAL DOORS AND MUST BE APPROVED BY PUBLIC WORKS DEPARTMENT PRIOR TO INSTALLATION.4. GATE LATCHES SHALL BE OF THE PLUNGER BAR TYPE OR EQUIVALENT AS APPROVED BY THE PUBLIC WORKS DEPARTMENT.5. SEE ATTACHED SPECIFICATIONS, NOTES AND PROCEDURES.
TRASH ENCLOSURE DETAIL MATERIAL SPECIFICATIONS:
1. CONCRETE BLOCK: 6" MINIMUM IN SIZE. ASTM C90.2. REINFORCING STEEL: ASTM 615. GRADE 40.3. ACCEPTABLE SOIL TYPES:
A. MIN. ALLOWABLE BEARING: 1000 LBS/SQ. FT.B. MIN. LATERAL BEARING: 100 LBS/SQ. FT./FT.C. MAX. EXPANSION INDEX: 20
4. CONCRETE: 2000 LBS/SQ. IN. IN 28 DAYS.5. MORTAR: 1: 1/4:3 (PORTLAND CEMENT: HYDRATED LIME OR LIME PUTTY: SAND. BY VOLUME).6. GROUT: 1:1/10:3 (PORTLAND CEMENT: HYDRATED LIME OR LIME PUTTY: SAND BY VOLUME). MIX TO FLOW WITHOUT SEGREGATION. GROUT MAY CONTAIN 2 PARTS PEA GRAVEL (3/8" MAX. SIZE).7. MINIMUM COMPRESSIVE STRENGTH: 2000 LBS/SQ. IN. REFER TO UBC TABLE 24-B FOR OTHER TYPES OF CEMENT.
GENERAL NOTES:
1. FOOTINGS SHALL BE IN COMPACTED NATURAL SOIL OR CERTIFIED FILL.2. BLOCKS TO BE STAGGERED (RUNNING BOND).3. ALL CELLS CONTAINING REINFORCING STEEL SHALL BE GROUTED.4. APPROVED GROUT STOPS ARE REQUIRED BELOW HORIZONTAL STEEL IN PARTIALLY-GROUTED WALLS. BAGS, NEWSPAPERS, ETC. ARE NOT APPROVED GROUT STOPS.5. INITIAL BED JOINT SHALL BE 1/4" MIN. 1" MAX. SUBSEQUENT BED JOINTS SHALL BE 1/4"-MIN., 5/8" MAX.6. VERTICAL CONTINUITY OF CELLS SHALL BE UNOBSTRUCTED. MORTAR PROJECTIONS SHALL NOT EXCEED 1/2" FOR 6" AND LARGER BLOCK. MORTAR DROPPINGS OR OTHER FOREIGN MATTER ARE
NOT PERMITTED IN CELLS AND MUST BE REMOVED.7. EXPANSION JOINTS REQUIRED AT 60'-0" MAX. INTERVALS.8. REQUIRED BAR LAPS:
A. VERTICAL STEEL: 30 BAR DIAMETERS.B. HORIZONTAL STEEL: 40 BAR DIAMETERS.C. WIRE JOINT REINFORCEMENT IN THE MORTARED BED JOINT: 75 WIRE DIAMETERS OR IN ALTERNATE BED JOINTS OF RUNNING BOND. 54 DIAMETERS PLUS TWICE THE BED JOINT SPACING.
9. WHERE HORIZONTAL WIRE JOINT REINFORCEMENT IS REQUIRED OR UTILIZED. IT SHALL BE EQUIVALENT TO TWO 3/16' DIAMETER BARS CONNECTED AT 16" INTERVALS BY NO. 9 GAUGE WELDED WIRE.10. FOR PIPES AND CONDUIT EMBEDDED IN MASONRY, REFER TO SEC. 24-07(G). UBC. 21. 3" MIN. COVER REQUIRED FOR REINFORCEMENT IN CONCRETE WHICH IS CAST AGAINST EARTH.
INSPECTION PROCEDURES:
1. FOUNDATION: AFTER TRENCHES ARE DUG, STEEL IS TIED IN PLACE AND BEFORE ANY CONCRETE IS POURED.2. PRE-GROUT: AFTER ALL BLOCKS (EXCEPT CAP) ARE IN PLACE. VERTICAL AND HORIZONTAL STEEL IS IN PLACE, GROUT STOPS (FOR PARTIALLY GROUTED MASONRY) ARE IN PLACE AND PRIOR TO
GROUTING.
TRASH ENCLOSURE GENERAL REQUIREMENTS
NOTES:
(2) EQUAL (+/-6'-0") WIDE x6'-0" HIGH MTL. GATES, TYPE 'B' 1 1/2" DECKING, 22GA. W/ T.S. 5x5x.1875 BAR CROSS BRACING WELD AND GRIND SOOTH ALL CONNECTIONS, TYP. PRIME AND PAINT COLOR TO MATCH ENCLOSURE OUTSIDE FINISH. INTERIOR WALLS TO BE PAINTED WITH EPOXY PAINT, COLOR TO MATCH EXTERIOR FINISH. CONCRETE SLAB TO BE SEALED PER FINISH SCHEDULE.
GATE HARDWARE:
1. ALL HARDWARE AND ACCESSORIES SHALL BE HEAVY GALVANIZED.2. GATE STOP - MUSHROOM TYPE OR FLUSH PLATE WITH THE ANCHORS SET IN CONCRETE TO ENGAGE THE CENTER DROP ROD
GATE GENERAL REQUIREMENTS
63.4.1 GALV. FRAME
TYPE 'B' 1 1/2" DECKING. TACK WELD TO FRAME; CRIMP EDGES
A HEAD B LATCH3/4" DIA. SOLID SLIDE BOLT
1" DIA. GALV. PIPE, FASTEN/WELD TO GATE FRAME (TYP)
NOTE:PRIME AND PAINT ALL METAL WORK TO MATCH BLOCK WALL
6" PIPE 3" PIPE 3" PIPE
6" DIAMETER GUARD POST
6" C.F.
#4xCONT. E.W. @ 4'-0" O.C.
SLEEVE FOR CANE BOLT (TYP.)
18 GA. PAINTED METAL GATE (BOX RIB) WITH BRACKET FOR PADLOCK TYP.
7" THICK PCC SLAB W/ 6"x6"-1.4x1.4 W.W.F. ON 6" GRAVEL BASE
CONST. JOINTS @ 10'-0" O.C.
CONC. FOOTING
4
A0.20
A0.20
5
A0.20
8
2
A0.20
3
A0.20
8' - 3"5' - 0"5' - 2 1/2"2' - 2 1/2"
22' - 0"
5' - 1 1/2"5' - 2"
NOTE:FINAL LAYOUT TO BE CONFIRMED WITH AHJ & LOCAL WASTE MANAGEMENT SERVICE FOR REVIEW PRIOR TO BEING SUBMITTED FOR BUILDING PERMIT TO ENSURE ALL LOCAL & SITE SPECIFIC REQUIREMENTS.
DESIGN OF ENCLOSURE TO BE APPROVED BY LANDLORD PRIOR TO FINAL PERMIT ISSUANCE.
GC TO SEAL CONCRETE INSIDE TRASH ENCLOSURE
13' -
5"
20' -
0"
7' -
10"
18GA. CLEANED, PRIMED & PAINTED METAL GATE (BOX RIB)
5"x5"x1/4" TS EMBEDDED 12" INTO FOOTING
7' -
2"
CANE BOLTS
BRACKETS FOR PADLOCKS
22' - 0"
5"x5"X1/4" T.S. EMBEDDED 12" INTO FOOTING
7' -
10"
13' - 5" 5"
STUCCO; PAINT EP1
2' - 6"
5' -
0"
FINISH GRADE
6"
U-BARS. 6-#4 VERTICAL BARS WITH STANDARD HOOK.
6"
10"
TIES #3 & 12" O.C. PROVIDE 3 TIES @ 1 1/2" O.C. @ TOP OF PIER.
LOCATE 3 - #3 TIES IN TOP 5"
ANCHOR BOLTS 2X18X1/4 BY GC
CHAMFER
1 1/2" NON-SHRINK GROUT
BASE PLATE BY OTHERS WELDED TO POLE GROUT BACK FLUSH WITH TOP OF BASE AFTER SETTING AND ALIGNING POLE
SECTION
3"
3"3'
- 0"
4' -
0"
CONCAVE TOP CONCRETE SURFACE
6" DIAMETER GALVANIZED STEEL PIPE FILLED W/ CONCRETE. PRIMED & PAINTED SAFETY RED.
FINISH SURFACE
18" DIA. CONCRETE FOOTING
(PIE
R H
EIG
HT
ABO
VE
SOIL
)
h1 =
2'-0
" @ [p
arki
ng lo
t] &
0'-6
" @ [s
ide
wal
k]
(PIE
R E
MB E
DM
ENT)
L =
5'-0
"
LIGHT POLE
POLE GROUND LUG
HAND HOLE
BOLT COVER
POLE BASE
1 1/2" CHAMFER
ANCHOR BOLTS (4 THUS.)
GRADE
(6) #5 VERTICAL REBARS
#3 REBAR TIES AT 10" O.C.
POWER CONDUIT
GROUND CONDUIT
#8 GROUND IN 3/4" PVC
THERMOWELD TO 5/8" X 6'-0" GROUND ROD2" CLR
3" C
LR
11" DIA.
BASE
BASE
(4) 3/4" DIA. CAST-IN-PLACE HOOK ANCHOR BOLTS (ASTM F1554-55) [PROJECTION =3 1/2", LENGTH = 30", HOOK LENGTH = 3"]
NOTE: 1. CONCRETE TO BE 2500 PSI COMPRESSIVE STRENGTH @ 28 DAYS.2. CONCRETE SHALL HAVE A MAXIMUM WATER/CEMENT RATIO OF 0.55.3. CONCRETE SHALL BE NORMAL WEIGHT AND BE AIR ENTRAINED WITH 6% (+/-) 1.5% ENTRAINED AIR BY VOLUME @ POINT OF DISCHARGE.4. GC TO VERIFY ANCHOR BOLT PATTERN AND CONDUIT PLACEMENT WITH OWNER'S VENDOR PRIOR TO POUR. G.C. WILL BE RESPONSIBLE FOR INSTALLATION CONFLICTS RESULTING FROM ANCHOR BOLTS INCORRECTLY PLACED.
ANCHOR BOLT PLAN
POLE BASE DETAIL
ANCHOR BOLT PLAN
PRO
JEC
TIO
N
LEN
GTH
HOOK LENGTH
1'-6"
NOTE: GC TO VERIFY ANCHOR BOLT PATTERN AND CONDUIT PLACEMENT WITH OWNER'S VENDOR PRIOR TO POUR. G.C. WILL BE RESPONSIBLE FOR ANY INSTALLATION CONFLICTS RESULTING FROM ANCHOR BOLTS INCORRECTLY PLACED.
1'-8" PREVIEW BD.
2' - 0" MENU BD.
5' -
0"
12" M
IN6"
ANCHOR BOLTS 5/8" -11x18 LG. W/ A 2" BEND (4 REQ'D) BY GC
G.L.
DESIGN SPEC.: 3000 P.S.I. CONC. 0.6 CU. YDS.
DETAIL N.T.S.
SECTION
DETAIL 1/2" = 1'-0"
4".
NUT
LOCK WASHER
FLAT WASHER
LEVELING NUT
NOTE: TRASH ENCLOSURE ROOF CANOPY TO BE INCLUDED ONLY WHEN REQUIRED BY AHJ.
SOLID GROUT ALL CORES
#5 BARS @48" O.C. CONT. THRU WALL & INTO FTG. W/ 3" HOOK
8"x8"x16" CMU WALL W/ DUR-O-WALL EVERY SECOND COURSE. PAINT TO MATCH BUILDING
#5 HORIZ. BAR @ MID-HEIGHT; TIE TO #5 VERT. BAR (TYP)
6" P.C.C. SLAB ON 6" AGG. BASE W/ #4 CONT. E.W. @ 4'-0" O.C.
#5 HORIZ. BAR @ TOP (TYP) TIE TO #5 VERT. BARSNOTES:
1. STUCCO MAY BE OMITTED IF CMU IS SPLIT FACE BLOCK, SLUMP STONE BLOCK OR FLUTED BLOCK
2. FOOTINGS SHALL EXTEND 18" MIN. BELOW ADJACENT FINISH GRADE/SURFACE OR BELOW FROST DEPTHS PER LOCAL CODES. SEE SOILS REPORT FOR ANY ADDITIONAL DESIGN CRITERIA
#5 BARS CONT. TOP & BOTTOM
PAVEMENT SURFACE AS SPECIFIED
6"1'
- 6"
8"
CLR
.3"
CURBGUARD POST BOLLARD RE: 8/A1.01
4"
OUT LINE OF BASE COVER
1/2" STL BASE PLATE
6 1/
2"
10"
4 3/
4"
4" 4"
1" CONDUIT (FOR AUDIO)
1 5/
8"
4"4" 1" ELECTRICAL CONDUIT (FOR SIGN LIGHTING)
ANCHOR BOLT & CONDUIT SETTING
DETAIL 1" = 1'-0"
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A0.20
XXXXX
BID & PERMIT
XX-XX-XX
SITE DETAILS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1" = 1'-0"4
TRASH ENCLOSURE SECTION @ SIDECURB
1 1/2" = 1'-0"5
JAMB DETAIL
1/4" = 1'-0"1
ENLARGED TRASH ENCLOSURE PLAN 1/4" = 1'-0"
2
TRASH ENCLOSURE - FRONTELEVATION
1/4" = 1'-0"3
TRASH ENCLOSURE - SIDE ELEVATION
1/2" = 1'-0"7
CLEARANCE BAR FOOTING
1/2" = 1'-0"8
GUARD POST BOLLARD
1/2" = 1'-0"9
FDN - POLE DETAIL
1/2" = 1'-0"10
MENU FOOTING
REVISIONS
NO. DATE DESCRIPTION
1/2" = 1'-0"6
TRASH ENCLOSURE ROOF CANOPY
1" = 1'-0"11
TRASH ENCLOSURE SECTION @ REAR
2424
2436
S2442
F
TEA
2424
2424
S1424
S2448
S2448
S2448
2436
G
A1.512
A1.50
A1.51
3
4
A
B
C
D
D.1
A3.10
1
UPP
ER G
LASS
PAN
ELS
PRO
VID
ED/ I
NST
ALLE
D B
Y VE
ND
OR
LOW
WAL
L BY
GC
6' -
0"5'
- 4
1/2"
1' -
8 1/
2"37
' - 5
1/2
"5'
- 4"
8"
DINING
100
1
A1.60
8
A1.61
3
A1.61
6
A1.61
4
A1.61
1
A1.61
120
121
EXIT
EXIT
104
EXIT
104
5
A5.63
7
A5.10
TYP. ALL INTERIOR RESTROOM WALLS
105
8
A6.01
8
A6.01
8
A6.01
3
A1.60
2
A1.61
141
105
111
112112
A5.62
1
117
117
108
117
1 2 3 4 5
OVERALL
75' - 3 3/4"
OV
ERAL
L
37' -
9 1
/4"
OV
ERAL
L
44' -
8 3
/4"
15' -
4 3
/8"
8' -
0 3/
4"13
' - 0
3/8
"8'
- 0
1/2"
102
103
105
107
106
108
101
27' - 6 1/2" 10' - 8 3/4" 11' - 4 3/4" 25' - 5"
W2B
W1B
W1W1B
W1B
2' - 1" 3' - 9"
125
B
1' - 9 1/2" 4' - 11" 17' - 6" 5' - 1 1/2" 10' - 9" 8' - 10 1/2" 8' - 8" 19' - 3"
D D
116
116
117
1' -
4 1/
2"6'
- 10
"21
' - 6
"7'
- 9"
117
3' -
4"
6' -
6 1/
2"2'
- 3
1/2"
5' -
4 1/
2"
A
C
E2
7' - 0 1/2"
3' -
6 1/
2"4'
- 4"
3' - 8"3' - 8"
3' -
3 1/
2"
3' -
6 1/
2"3'
- 6
1/2"
120
WOMENS
110
MENS
111
108D4D1D1
D1
D1
D2
D1
104
6' -
5"1'
- 11
1/2
"
10' -
11"
3' - 0" 5' - 5 1/2" 9' - 8 1/2" 9' - 1 1/2" 9' - 7 1/2"
1' -
0"4'
- 2
1/2"
12' -
7 1
/2"
4' -
0 1/
2"
2' - 7 1/2"
136
110
116
116
116
116
116
110110
116116
116
116
116
3' -
7 1/
2"8'
- 8
1/2"
3' -
11 1
/2"
6' -
1"
2' - 6 1/2"
7"
6' - 6 1/2"
2' - 11" 6' - 8 1/2"
108
108
1' -
1"6'
- 0"
5' -
11"4'
- 5
1/2"
1' -
1"0"
104
117
103118
118
118
109
109
126
123
OFFICE
105
WATER HEATER
114
B.2
4' - 9" 15' - 0" 7' - 9 1/2" 10' - 9" 3' - 10" 4' - 0" 3' - 7" 14' - 1" 7' - 10 1/2" 3' - 5"
2' - 11"
106
105
105
101
18' -
5"
2' -
8"
105
105
106
105
105106
3' - 2"
108
2 1/
2"
105
8' - 8 1/2"
117
132
12' - 5"
12' - 0"
VESTIBULE
113
CUSTOMER PICK-UP
101
SALSA BAR
100a
STORAGE
106
COOLER
107
W1B
W2BW2B
5
A1.61
139
139 139139
106
111
111 111
107
106
106
142
D2
D1
+44" A.F.F.
SERVING
119
DRIVE-THRU
109
WORK AREA
118
9' - 8"
A1.00
3
133
D1
3' - 2"
3' -
1"
2' -
7"
ALIG
NAL
IGN
2' - 3"
11 1
/2"
1' -
2 1/
2" 1' - 2 1/2"
10' - 5"
1' - 11 1/2" 3' - 3"
INTERIOR EXTERIOR
W1 5 1/2" WOOD STUDS WITH SHEATHING, STUCCO TO EXTERIOR, 1 LAYER 5/8" GYP TO INTERIOR
W1B SAME AS W1 WITH 1" BRICK ON EXTERIOR SIDE INSTEAD OF STUCCO
PARTITION TYPES - METAL STUD INTERIOR
6" METAL STUDS WITH NO INSULATION IF 1 HR RATED =UL# U-465D2
GENERAL PARTITION NOTES:ALL DIMENSIONS TAKEN TO FACE OF STUDS, MASONRY OR GRID LINE U.N.O.
1. REFER TO STRUCTURAL DRAWINGS FOR LOAD BEARING STUD GAUGES2. USE MOLD RESISTANT BOARD AND 12" DUROCK IN ALL RESTROOMS & WATER HEATER
CLOSET AND ALL OTHER WET AREAS. PER DETAIL 5/A5.63.3. ALL GYPSUM BOARD IS 5/8" (TYPE 'X') UNLESS NOTED OTHERWISE (UNO)4. ALL FIRE RATED WALLS CONTINUOUS TO DECK OR HARD LID. TYP. REF DOCS. ALL GYPSUM
BOARD IS INSTALLED TO DECK (UNO). AT DEFLECTION TRACKS - HOLD GYP DOWN FROM DECK PER MANUFACTURERS WRITTEN INSTRUCTIONS.
5. AT ANY EXTERIOR WALLS - ENSURE A VAPOR BARRIER IS INSTALLED6. ANY WALLS RECEIVING TILE TO HAVE NATIONAL TILE ASSOCIATION APPROVED BACKING TYP. 7. ALL WALLS ARE TO BE BRACED ABOVE THE FINISHED CEILING AS RECOMMENDED BY THE
METAL STUD MANUFACTURER TO PREVENT WALL MOVEMENT.8. ALL WALLS WHICH SEPARATE A SPACE FROM UNCONDITIONED AREA (E.G. EXTERIOR,
COVERED SERVICE/DELIVERY, INTERIOR UNCONDITIONED SPACE), SHALL HAVE THERMAL BATT INSULATION INSTALLED PER SPECIFICATION REQUIREMENTS.
9. ALL PARTITIONS ENCLOSING PLUMBING TO BE INSULATED.10. ALL ELECTRICAL, MECHANICAL ROOMS TO HAVE SOUND INSULATION WITHIN THE WALL.11. PER MOLD PREVENTION GUIDELINES, NEVER INSTALL GYPSUM WALL BOARD IN DIRECT
CONTACT WITH CONCRETE FLOORS. GC TO PROVIDE A CONTINUOUS BEAD OF CAULK THE ENTIRE LENGTH OF WALL BETWEEN GYP AND FLOOR.
12. USE DEFLECTION TRACKS WHEN EVER STUD WALLS CONNECT DIRECTLY TO STRUCTURE ABOVE
HORZ. BRACING AS REQ, REF STRUCT.TYP. TO ALL MTL. STUDS
3 5/8" MTL. STUDS
D1 3 5/8" METAL STUD
PARTITION TYPES - WOOD STUD EXTERIOR
5/8" GYP. BD.5 1/2" WOOD STUD WITH R-19 BATT INSULATION
AIR/MOISTURE BARRIER
STUCCO
2 1/2" METAL FURRING STUD E
HORZ. BRACING AS REQ, REF STRUCT.TYP. TO ALL MTL. STUDS
1 1/2" MTL. STUDS
WALL
1/2" WOOD SHEATHING
3 5/8" METAL STUDS WITH INSULATIOND3
6" METAL STUDS WITH INSULATION D4
SAME AS W1B WITH NO INSULATION AND NO GYP. BD.W2B
1. ALL CONSTRUCTION SHALL COMPLY WITH CURRENT CODES, ADDITIONS, ALL AMENDMENTS, AND LOCAL CODES.
2. ALL EXPOSED WALLS IN RESTROOMS AND ALL PLUMBING WALLS TO BE COVERED IN CERAMIC TILE OR FRP. PER DRAWINGS, FLOOR TO CEILING AS INDICATED IN SPECS, UNLESS OTHERWISE NOTED ON PLANS.
3. ALL CONDENSATION LINES (INDIRECT WASTE WATER) SHALL BE ACCESSIBLE TO FLOOR SINKS, INSTALLED FLUSH WITH FLOOR, 1/2 EXPOSED, WITH GRATE.
4. ALL DOORS, WINDOWS, AND OTHER JOINTS IN THE EXTERIOR WALLS SHALL BE FULLY INSULATED.
5. A CERTIFICATE OF COMPLIANCE SHALL BE PROVIDED FOR ALL EXTERIOR DOORS AND WINDOWS.6. ALL CONDUIT, PLUMBING, ETC. NOT CONCEALED WITHIN WALLS, MUST BE INSTALLED AT LEAST 6
INCHES OFF THE FLOOR AND 1 INCH AWAY FROM WALLS. ALL EXPOSED FLEX CONDUITS TO BE SEAL-TIGHT OR EQUIVALENT.
7. ALL EQUIPMENT, INCLUDING (BOTTOM) SHELVING, MUST BE SUPPORTED BY (6) INCH HIGH, ROUND, STAINLESS STEEL LEGS OR BE ON 6" CASTORS.
8. G.C. TO PROVIDE ALL NECESSARY BLOCKING OR REINFORCEMENT AT ALL ATTACHMENTS TO WALLS INCLUDING BUT NOT LIMITED TO BLOCKING FOR SHELVING, SINKS, SOAP DISPENSERS, AND GRAB BARS.
9. GENERAL CONTRACTOR SHALL PROVIDE STRUCT. SUPPORT FOR ALL ROOF MOUNTED OR SUSPENDED MECHANICAL & FOOD SERVICE EQUIPMENT. AS REQ'D.
10. GENERAL CONTRACTOR TO VERIFY WITH THE OWNER THE EXACT EXTENT OF WORK TO BE COMPLETED PRIOR TO CONSTRUCTION.
11. FLASHING AND COUNTER FLASHING. EXTERIOR OPENINGS EXPOSED TO THE WEATHER SHALL BE FLASHED IN SUCH A MANNER AS TO MAKE THEM WEATHERPROOF.
12. INSULATION MATERIAL SHALL MEET THE CURRENT IBC AND IEEC WITH LOCAL & CITY CODES.13. THE GENERAL CONTRACTOR AND ELECTRICAL SUB-CONTRACTOR MUST VERIFY A FULL 3' - 0"
CLEAR SPACE IN FRONT OF ELECTRICAL EQUIPMENT PRIOR TO POURING CONCRETE FOUNDATION SLAB. NOTIFY THE ARCHITECT IMMEDIATELY IF THIS DIMENSION IS IN QUESTION.
14. PROVIDE DEEPENED FOOTINGS (GRADE BEAMS) AS REQUIRED WHERE ADJACENT FINISH GRADE IS SUBSTANTIALLY BELOW (OR SLOPING AWAY FROM) THE FINISHED FLOOR SEE GRADING PLANS.
15. PRIOR TO BID, CONTRACTOR SHALL VISIT THE SITE TO ADEQUATELY DETERMINE ALL PRE-EXISTING CONDITIONS AND THE FULL EXTENT OF ALL REQUIRED DEMOLITION. BY THE ACT OF SUBMITTING A BID, THE CONTRACTOR WILL BE DEEMED TO HAVE COMPLIED WITH THE FOREGOING, TO HAVE ACCEPTED SUCH CONDITIONS, AND TO HAVE MADE ALLOWANCES THEREFORE IN PREPARING HIS BID.
16. GENERAL CONTRACTOR TO CONFIRM LAYOUT W/ APPROVED SEATING PLAN BY OWNER.17. SHEET ENTIRE BUILDING WITH PLYWOOD. REFER TO STRUCTURAL DRAWINGS FOR
SHEAR AS REQUIRED.18. ALL EXTERIOR DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A
KEY OR ANY SPECIAL KNOWLEDGE.19. FOR INTERIOR ELEVATIONS, SEE SHEETS A5.60, A5.61, A5.62, A5.63.20. ALL DIMENSIONS TO FACE OF STUDS.21. PVC PIPE SHALL NOT BE USED IN COOK-LINE WALLS.22. AT THE TIME OF ROUGH INSTALLATION OR DURING STORAGE ON THE CONSTRUCTION
SITE AND UNTIL FINAL STARTUP OF THE HEATING AND COOLING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF DUST OR DEBRIS WHICH MAY COLLECT IN THE SYSTEM.
23. SEAL/ FOAM ALL PENETRATIONS AT EXTERIOR WALL PLATE PRIOR TO INSULATION AND DRYWALL.
18' -
9"
6 1/2"
1 1/2"
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A1.00
XXXXX
BID & PERMIT
XX-XX-XX
FLOOR PLAN
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/4" = 1'-0"1
FIRST FLOOR
KEYNOTE LEGEND - NEW
141 HOT WATER AND DRAIN PIPES ACCESSIBLE UNDERLAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED.THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDERLAVATORIES.
142 SODA RACK AND WATER FILTER PROVIDED AND INSTALLEDBY OWNER VENDOR. GC TO PROVIDE ALL PLUMBING POCPER OWNER VENDOR INSTALLATION INSTRUCTION. GC TOSCHEDULE OWNER VENDOR INSTALL 2 WEEKS OUT.
425 PREFERRED GAS METER LOCATION. FINAL LOCATION TO BEDETERMINED BY GAS SERVICE COMPANY.
KEYNOTE LEGEND - NEW
117 VISION ARTWORK PROVIDED BY VENDOR AND INSTALLED BYGC. SEE INTERIOR ELEVATIONS ON SHEET A5.60 FORARTWORK TYPE AND PLACEMENT. SEE SHEET A6.00 FORARTWORK SCHEDULE.
118 ALL DINING ROOM WINDOWS TO HAVE BLACK ROLLERSHADES. BY OWNER.
120 SEATING PACKAGE BY SEATING VENDOR - TYP.
121 DECORATIVE GLASS SCREEN WALL. GC TO PROVIDE ANDINSTALL LOW WALL. COORDINATE PLACEMENT OF WALLUNDER FRAMED BEAM OVERHEAD WITH OWNER VENDORSHOP DRAWINGS. OWNER VENDOR TO PROVIDE AN DINSTALLALL METAL AND GLASS COMPONENTS.
123 SALSA BAR BY STAINLESS STEEL VENDOR TO HAVE SELFREFRIGERATION. 34" MAX. HT. TO SERVING AREA.
124 PROVIDE 5" PIPE CHASE IN WALL TO GET BUNDLE FROMABOVE CEILING TO UNDER COUNTER. FOAM ALLPENETRATIONS (TYP).
125 QUEUE RAIL SEE 3/A5.10. BY OWNER VENDOR.
126 FOR DRIVE-THRU WINDOW SEE A6.01. VERIFY WINDOW TYPEPER STATE.
131 1'-0" CHASE BY FSEC.
132 3-5/8" METAL STUD WALL 3'-4" HIGH.
133 48"X48" PLYWD. FOR TELEPHONE BACKBOARD, CENTER OFPLYWD. TO BE @48" A.F.F.
136 ROOF LADDER.
139 PICTURE LIGHT OUTLET (LF-14). TYP. OF 5. SEE ELEV. GC TOCOORDINATE LOCATION WITH OWNER VENDOR SHOPDRAWINGS.
KEYNOTE LEGEND - NEW
101 FLUSH MOUNTED ELECTRICAL PANELS IN 6" WALL. SEEINTERIOR ELEVATIONS SHEET A5.60 FOR SUB-PANEL LAYOUT.
103 SODA COUNTER BY STAINLESS STEEL VENDOR. 34" MAX.HEIGHT TO SERVING AREA. WILL DRAIN TO KITCHEN FLOORSINK.
104 PROVIDE EXIT SIGNS WHERE NOTED PER ELECTRICAL PLAN.
105 PROVIDE FLOOR DRAINS FLUSH WITH FINISH FLOOR - SEEPLUMBING PLAN AND KITCHEN EQUIPMENT VENDOR PLAN.SEE DETAIL 4/A5.10 FOR SLOPE REQUIREMENTS.
106 PROVIDE AND VERIFY EXACT LOCATIONS OF FLOOR SINKWITH EQUIPMENT SPECIFICATIONS AND KITCHEN EQUIPMENTVENDOR. SEE DETAIL 5/A5.10 AND "K" SHEETS.
107 ELECT. MAIN SWITCH GEAR AND METER G.C. TO VERIFYDIMENSIONS AND LOCATIONS W/ SITE CONSTRAINTS.
108 PROVIDE WATER RESISTANT GYPSUM BOARD & 12" DUROCKTHROUGH-OUT KITCHEN, WATER HEATER CLOSET AND ALLOTHER WET AREAS.
109 PROVIDE PLYWOOD BACKING AT ALL WALL MOUNTEDSHELVES AND EQUIPMENT. SEE SHEET A7.00.
110 2" MIN. AIR SPACE BETWEEN WALL AND COOLER WALL.
111 FSEC TO PROVIDE CLOSURE TRIM AT JUNCTION OF WALK-INCOOLER WALLS WITH GC WALL FINISHES.
112 4" PVC CONDUIT FOR SODA LINES FROM 6" ABOVE CEILING TOSWEEP AT BOTTOM OF WALL (BOTTOM EDGE OF SWEEP TOEXIT WALL @ 12" A.F.F.). RUN SODA LINES OVERHEAD TO BAG'N' BOX LOCATION. SEE DETAIL 10/A1.70.
116 GC TO INSTALL WALL GUARDS AT OUTSIDE CORNERS ANDEND OF WALLS PROVIDED BY STAINLESS STEEL VENDOR.TYP. SEE DETAIL 6/A5.10.
NOTES TO CONTRACTOR
REVISIONS
NO. DATE DESCRIPTION
1/2" = 1'-0"3
ENLARGED SERVICE COUNTER PLAN
A
B
C
D
D.1
SLO
PE
DO
WN
AT
1/2"
/12"
1/4" / 12" SLOPE
1/4" /
12" S
LOPE
1/4" /
12" S
LOPE
SLO
PE
DO
WN
AT
1/4"
/ 12"
SLO
PE
DO
WN
AT
1/4"
/12"
2
A1.60
1
A1.60
8
A1.61
3
A1.61
6
A1.61
4
A1.61
1
A1.61
1
A1.41
5
A1.41
3
A1.41
1
A1.41
5
A1.41
13
A1.41
304
307
3
A1.60
13
A1.41
300
301
301
300
1/4" / 12" SLOPE1/4" /
12" S
LOPE
1/4" /
12" S
LOPE 1/4" / 12" SLOPE
1 2 3 4 5
B.2
315
17
A1.41
5
A1.61
1/4" /
12" S
LOPE 1/4" / 12" SLOPE
RT1
RT2
KF4
307
KF1
310
307
307
EF1
KF3
MAU1
1. CONTRACTOR TO CONFIRM THAT ALL AREAS ARE PROVIDED WITH POSITIVE DRAINAGE PRIOR TO SHEATHING OF ROOF.
2. ALL ELEVATIONS ARE GIVEN FROM TOP OF FLOOR SLAB ELEVATIONS.3. PROVIDED INSULATION BETWEEN ALL ROOF FRAMING AND BETWEEN STUDS AT EXTERIOR WALL
TYPICAL U.N.O.4. VERIFY SIZES AND LOCATIONS OF ALL OPENINGS PLATFORMS ETC. WITH RESPECTIVE
CONTRACTORS.5. WHERE VENT PIPES PENETRATE SHEATHING REFER TO DETAIL 9/A1.41.6. ROOFING FIRE RETARDANT PER IBC TABLE 1505.7. FOR ALL CURBED ROOF OPENINGS REFER TO DETAIL 13/A1.41.8. ATTIC SPACES SHALL BE DIVIDED WITH DRAFTSTOPS INTO HORIZONTAL AREAS NOT EXCEEDING 3000
S.F. (60 LINEAR FEET MAXIMUM).9. ROOF CRICKETS SHALL BE CONSTRUCTED OF RIGID INSULATION. MAINTAIN MINIMUM SLOPE OF 3/8"
PER FOOT. CRICKET LOCATIONS ARE SHOWN ON ROOF PLANS. PROVIDE CRICKETS AS SHOWN ON PLAN AT HIGH SIDE OF ALL EQUIPMENTS.
10. ALL CURBS TO BE MINIMUM 8" HIGH EXCEPT A/C UNIT WHICH BE 14" HIGH AND PER MANUFACTURER RECOMMENDATION.
11. FOR ALL PENETRATIONS & SUPPORT OF PIPE @ ROOF SEE SHEET A1.41.12. FOR ALL SUPPORT OF CONDENSATE LINES SEE SHEET A1.41.13. INSULATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.14. VERIFY FINAL LOCATIONS OF ALL HVAC UNITS, FAN UNITS AND OTHER EQUIPMENT WITH MECHANICAL
AND TRUSS DRAWINGS AND WITH ALL PERTINENT FIELD CONDITIONS.15. ALL MECHANICAL ROOF EQUIPMENT ON ROOF SHALL BE SCREENED BY THE PARAPET.
ROOF DRAIN HEIGHT, FLUSHWITH ROOF COLOR TO
MATCH ADJACENT SURFACE
FLASHING W/ W.P.MASTIC & SEALANT BEAD
FLASHING W/ W.P. MASTICAND MECHANICALFASTENER BELOW
ROOFING ON RIGIDINSULATION ON METALDECK
WALL PER PLANS
CONTINUOUS BEAD OF SEALANTBOTH SIDES & ALL EDGES,TYPICALSIZE PER ROOF PLAN
2".
ABOVE ROOF
8". H
ROOF DRAIN LEADER FROM CANOPY ROOF
PIPE STRAPS SECURED TO WALL
"V2" DOWNSPOUT NOZZLE IN WALL
CONTINUOUS SEALANT
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A1.40
XXXXX
BID & PERMIT
XX-XX-XX
ROOF PLAN
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/4" = 1'-0"3
ROOF PLAN
ABBREVIATIONS & SYMBOLS
T.S. TOP OF SHEATHING
T.P. TOP OF PARAPET
O.D. OVERFLOW DRAIN
R.D. ROOF DRAIN
V.I.F. VERIFY IN FIELD
GENERAL DIRECTION OF WATER DRAINAGESLOPE
GENERAL NOTES
KEYNOTE LEGEND - NEW
300 3" ROOF DRAIN TYP. 2 LOCATIONS. SEE DETAIL 12/A1.41.
301 ROOF TOP UNIT. VERIFY LOCATION WITH MECHANICAL. FORROOF EQUIPMENT CURB SEE DETAIL SHEET A1.41.
304 ROOF MEMBRANE. MIN. TOTAL SOLAR REFLECTANCE OF 0.70AND MIN. THERMAL EMITTANCE OF 0.75 WHEN TESTED. SEEDETAIL 3/A1.41. GC TO PRICE MULITPLE MANUFACTURERS.
307 UTILITY EXHAUST FAN WITH CURBS. FOR ROOF EQUIPMENTCURB SEE DETAIL SHEET A1.41.
310 VENDOR TO SLOPE CANOPY AWAY FROM BUILDING.
315 ROOF HATCH. RE: SPECS.
3/4" = 1'-0"1
OVERFLOW SCUPPER DETAIL 3/4" = 1'-0"
2LAMB'S TONGUE DETAIL
REVISIONS
NO. DATE DESCRIPTION
A1.41
3
A1.41
2
ROOFING PER SPECIFICATIONS
PARAPET WALL
RIGID INSULATION CRICKET (MAINTAIN MINIMUM OF 1/8'' SLOPE AT FLOW LINES)
MEMBRANE ROOFING PER SPECIFICATIONS
ROOF FRAMING PER PLANS
NOTE: FOR ADDITIONAL INFORMATION SEE
4/A1.41
INSULATION PER SPECIFICATIONS
PLYWOOD DECKING
EXTEND ROOFING
PARAPET WALL
3x3 CANT. STRIP
ROOF MEMBRANE PER SPECIFICATIONS
NOTE: FOR ADDITIONAL INFORMATION SEE
4/A1.41
PER SPECIFICATION
PLYWOOD DECKING
30''
OR
60
'' R
OL
L (
no
te3)
30''
OR
60
'' R
OL
L (
no
te3)
30''
OR
60
'' R
OL
L (
no
te3)
30''
OR
60
'' R
OL
L (
no
te3)
TACK WELDS
HEAT-WELDED SEAM
PLATES AND FASTENERS: ROOF MEMBRANE
PLATES AND FASTENERS: WALL MEMBRANE
EDGE OF UNDERLYING SHEET
SHEET OVERLAP
HEAT-WELDED SEAMS
NOTE 1: THIS DETAIL APPLIES TO ROOF MEMBRANE WHEN MECHANICALLY FASTENED TO WALLS SO THAT THE SEAMS BETWEEN MEMBRANE SHEETS ARE VERTICAL
NOTE 2: THE ROOF MEMBRANE AT THE ROOF - TO - WALL TRANSITION SHALL BE ATTACHED USING THE SAME FASTENER SPACING USED FOR THE ROOF MEMBRANE IN THE PERIMETER AREA.
NOTE 3: 60 - INCH WIDE ROLLS SHALL NOT BE USED ON WALLS TALLER THAN 24 INCHES. 30 - INCH WIDE ROLLS CAN BE USED FOR ALL HEIGHTS.
NOTE 4: REFER TO THE SPECIFICATION FOR THE FASTENER SPACING REQUIREMENTS ON THE WALL AND ROOF DECK.
NOTE 5: OVERLAP WALL SHEETS A MINIMUM OF 6 INCHES.
NOTE 6: TACK WELD THE WALL MEMBRANE TO THE ROOF MEMBRANE AT THE ROOF - TO - WALL TRANSITION BETWEEN THE ROOF MEMBRANE FASTENERS.
NOTE 7: ALL HEAT - WELDED SEAMS MUST BE A MINIMUM OF 1 1/2 INCHES WIDE.
FLASHING LAPS 6'' SET IN VAKLEM 116, SEALANT TO SHOW AT EXPOSED LEADING EDGE
PARAPET WALL
METAL COPING
MEMBRANE UNDER JOINT
FOR PARAPET PROFILE SEE SECTIONS ON A1.60
1/2'' W
IDE GAP
BTWN. PIECES
LENGTH EA. PIECE
10' - 0" M
INIMUM
A1.41
3A1.41
2
RUN CAP SHEET UNDER COPING TYP
2x STUDS PER PLAN
2/8'' HEAD SCREW THRU 5/8'' STEEL/NEOPRENE WASHER @ 16' 0.C
COMPRESSION CLEAT
24 GA. G.I. FLASHING WITH CONTINUOUS CLEAT ON JIFFY SEAL, PAINT FLASHING TO MATCH
3”
2 1/
2”
ROOFING PER SPECIFICATIONS OVER 2 LAYERS BLDG. PAPER
EXTERIOR FINISH PER ELECATIONS
INSULATION
PLYWOOD DECKING
EXHAUST FAN
CANT. STRIP BY ROOFERROOFING PER SPECS.
EXHAUST FAN METAL DUCTING PER MECHANICAL DRAWINGS
LEVEL CURB BY G.C. SEE STRUCTURAL DRAWINGS
RUN ROOFING BENEATH FLASHING
LAG SCREW (1-1/4)EXHAUST FAN BASE TO WOOD CURB
MASTIC AT EDGES OF ROOFING FELTS
ROOF JACK
PLUMBING VENT STACK
STRIP IN WITH TWO PLIES OF FELT
SET FLANGE IN MASTIC -PRIME FLANGE BEFORE STRIPPING
4”MIN.
12'' MIN.
NOTES:
1. SHEET LEAD MINIMUM OF 2-1/2 LB. PER SQ. FOOT.
2. SEE DETAIL 'U' FOR MIN. CLEARANCE FROM PIPES WALLS AND CURBS.
SEAL WITH SEALANT
1 /4'' MINIMUM CLEARANCE TO UMBRELLA
DRAW BAND
WATERTIGHT UMBRELLA OVERLAPPING JACK BY RADIUS OF 3'' TO 4''
SHEET METAL ROOF JACK MINIMUM OF 8'' ABOVE ROOFING
1 /4'' MINIMUM CLEARANCE TO PIPE
8'' OVERLAP MIN. OF STRIPS
STEEL PIPE
3'' MINIMUM TO 4'' MAX. FLANGE SET IN MASTIC OVER ROOFING PRIME FLANGE BEFORE STRIPPING
TOP OF FLUE
RAIN CAP
VENTED ROOF
FLASH & COUNTERFLASH
VENTED CEILING PLATE
METALBESTOS FLUE
ROOF STRUCTURE
FLASHING STRIPS SET IN MASTIC
VENT CAP
2' -0
'' MIN
.
1' -0
'' MIN
.
MIN.
3”
3'' ROOF DRAIN W/ ABS DOME
CANT -TYP.
FINAL POINT OF TERMINATION LAMB'S TONGUE APPROVED LOCATION BY ARCHITECT OR BLDG. OFFICIAL
2x BLOCKING
RIGID INSULATION CRICKET
3'' CANT STRIP
TRUSSES PER PLAN
PARAPET WALL
BASE FLASHING
6'' MIN.
THUNDER BIRD COMBO ROOF DRAIN AND OVERFLOW W/ COPPER DRAIN BASIN (26" x 36") AND ABS DOME. INSTALL PER MANUFACTURER'S SPECIFICATIONS
RIGID INSULATION W/ 2X2 NAILING STRIP AT TOP BY ROOFING CONTRACTOR
METAL CURB BY EQUIPMENT MANUFACTURER
16D @ 12'' O.C.
SHAPED 2X LEVELING SHIM
CUT OPENING IN ROOF PER MECH DWG.
2X BLKG OR TOP CHORD OF TRUSS
ROOF SHEATHING
CANT
1/4'' X 1 1/2'' WOOD SCREWS SPACED PER MANUFACTURER'S RECOMMENDATION
ROOF MEMBRANE
26 GA. GALVANIZED STEEL FLASHING
3/8''φ LAG BOLTS, 1 1/2'' LONG
2 -3/4''φ STEEL BOLTS CADMIUM PLATED W/ LOCK WASHERS
2''x 3/16'' BEND GALVANIZED STEEL PLATE BRACKET. ONE NEAR EACH CORNER OF AC UNIT (4 REQ'D)
3/8''φ LAG BOLTS, 1 1/2'' LONG
1'' ROOFING NAILS @12'' O.C.
A/C UNIT OR FAN HOUSING
SLOPE 1/8'' PER FOOT
SLOPE 1/8''
PER FOOT
MINIMUM MINIMUM
VERIFY W/ MECHANICAL
MIN
.
1 1/
2”
2X BLOCKING
3X3 CONT. CANT STRIP
BASE FLASHING
ROOFING PER PLAN
SCREWS & NEOPRENE WASHER AT SLOTTED HOLES AT 12'' 0/C
ONE PIECE 18 GA. GALVANIZED SHEET METAL CAP OVER 3/4'' PLYWOOD OVER 2X8 AT 24'' O/C OVER ROOF SHEATHING
SIMPSON A35 AT 32'' 0/C TYP. W/ 1 1/2'' LONG WOOD SCREWS TYP.
DRAIN LINE SLOPE AS REQUIRED TO DRAIN CONNECTION
14 GA. 1'' GALV. STRAPS SCREWED TO BLOCK
FROM A/C UNIT DRAIN PAN
P -TRAP
TO ROOF JACK, DOWN THRU ROOF TO DRAIN
3'' AIR GAP
PROVIDE DRAIN NUT IN BOTTOM OF P. TRAP
4''X4''X8'' TREATED WOOD BLKS. PLACED AT 4' -0'' O.C. & ALL TURNS, JUNCTION IN LINES.
SET BOLTS IN ELEASTOMERIC SEALANT
ADJUSTS VERTICALLY & HORIZONTALLY
6'' M
IN. C
LR.
ABO
VE R
OOF
AT G
AS P
IPE
1. NRCA REAFFIRMS ITS OPPOSITION TO PIPES AND CONDUITS BEING PLACED ON ROOFS. HOWEVER, WHERE THEY ARE NECESSARY AND AVAILABLE, A PIPE ROLLER SUPPORT IS RECOMMENDED. THE DETAIL SHOWN IS GENERIC ONLY.
2. THIS DETAIL ALLOWS FOR EXPANSION AND CONTRACTION OF PIPES WITHOUT ROOF DAMAGE
NOTES:
VARIES
VARIESROOF
PARAPETVARIES
2' - 0" 2' - 4"
2' -
6"
0' -
2" M
IN.
TYP.
1' -
0"
MAX
.
1' -
4"
8" M
IN.
MAX
1' -
4"
7"7"
PAINTED/PREFINISHED.MTL.COPING
2" GALV. PIPE
2" DIA. GALV. STEEL PIPE
PROVIDE TREATED BLOCKING @ METAL STUDLOCATIONS, FULLY SEAL @ROOF MOUNTING BRACKETPENETRATIONS
SECTION
ELEVATION
PLAN
ALTERNATE: ACL INDUSTRIES ACL-203 PREFAB ALUMINUM UNIT-TEL:603=668-1267 FAX: 603-668-1281. GC PROVIDE PRICING ALTERNATE TO ARCHITECT & OWNER
TOP OF PARAPET
9"x9"x1/4" GALV. STEEL PLATEW/ (4) 3/8" DIA. BOLTSSET IN BED ROOFSEALANT & SEAL ALLEDGES AS PER ROOFMFG RECOMMENDATIONS
PROVIDE SEALANTAT ALL BOLT HEADS-TYP.
3/4" DIA. GALV.STEEL PIPEPAINTED W/NON-SKID PAINT
3/4" DIA. PIPE
2" DIA. PIPE
CLG. HT.RE: R.C.P.
VARIEST.O. JOIST
R 1 1/4"
6"
6"
12" T
YP.
3"
2 1/2"x2 1/2"x3/8" STL. ANGLE, W/ 1/2" EXP.BOLT EACH SIDE.
24" WIDE F.R.P. BD. FULL HGT.OF WALL BEHIND LADDER
1 LAYER OF 5/8" GYP. BD. ON 3SIDES (PAINTED) ON 3 5/8" MTL. STUDS WITH FRP FINISH TO ALLFACES OF ENCLOSURE SHAFT
2 LAYER OF 3/4" EXT. RATED PLY
STEEL DECK ANGLE
EXTEND MMB. FLSHG.UNDER CAP FLASHING
GALV. METAL FLASHING
ROOF HATCHREF: SPECS
30" MIN. EXTENDING SAFETY POST(BY MANUFACTURER)
ROOF ACCESS LADDER2 1/2"x3/8" STL RAILSW/ 3/4" DIA. x 1'-6" RUNGS.PAINTED BLACK BY G.C.
MULTIPLE-PLY MEMBRANE BASE FLASHING
REF: WALL TYPES
WALL ANCHORBLKG AS REQD
2 1/2"x3/8" BENT STL.BRACKET @MID POINT
ALTERNATE: ACL INDUSTRIES ACL-200 PREFAB ALUMINUM UNITTEL:603-668-1267 FAX: 603-668-1281.GC TO PROVIDE PRICING ALT TO ARCHITECT & OWNER
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A1.41
XXXXX
BID & PERMIT
XX-XX-XX
ROOF DETAILS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1 1/2" = 1'-0"1
TYPICAL CRICKET
1 1/2" = 1'-0"2
PARAPET DETAIL
1 1/2" = 1'-0"3
BASE FLASHING
1 1/2" = 1'-0"4
JOINT COVER @ PARAPET
1 1/2" = 1'-0"5
PARAPET
1 1/2" = 1'-0"7
EXHAUST FAN CURB
1 1/2" = 1'-0"8
VENT FLASHING
1 1/2" = 1'-0"9
PIPE PENETRATION
1 1/2" = 1'-0"14
FLUE PENETRATION
3" = 1'-0"12
ROOF DRAIN
1 1/2" = 1'-0"13
ROOF EQUIPMENT CURB
1 1/2" = 1'-0"10
CONDENSER PLATFORM
1 1/2" = 1'-0"11
CONDENSATE SUPPORT
1 1/2" = 1'-0"15
GAS PIPE ROLLER SUPPORT
1/4" = 1'-0"16
ROOF LADDER
REVISIONS
NO. DATE DESCRIPTION
1" = 1'-0"17
ROOF HATCH
FIRST FLOOR100' - 0"
3
A1.61
EP-2 AW-1
T-4
MF-1
BK-1
EP-2
5
A1.41
8' -
0"
8' -
0"
3
A1.60
404
415
404
EP-2 MF-1
123' - 11"
EQ EQ
403 420
5
A1.50
5
A1.50
BK-1
114' - 2 1/2"
120' - 0"
404
EQ 1' - 9 1/2"
MF-1
421
10' -
0"
10' -
0"
A
101
512 512 512
RT2 RT1 MAU1
427
FIRST FLOOR100' - 0"
2
A1.60
1
A1.60
8
A1.61
6
A1.61
4
A1.61
1
A1.61MF-1
5
A1.41BK-1
BK-1
5
A1.41
8' -
0"
TYP
8' -
0"
AW-1AR2 AR2 AR2
EP-1
11' -
3"
T-4
T-4
121' - 0"
123' - 11"
8' -
0"
118' - 11 1/8"
407
407407
409 409 409
410 410410
408420
420403
MF-1
MF-1
5
A1.50
5
A1.50
421
421
5
A1.61
420
417 417420420
404
404
2' -
0".
BOTT
OM
OF
CH
ANN
EL L
ETTE
RS
19' -
0"
EQ EQ EQ EQ
10' -
0"B
D D102
417
BK-1
9' - 8"
512
RT1 RT2
512
427
417
PPG - PPG1001-5 DOVER GRAYEXTERIOR GRADE EGGSHELL FINISH
McNear BRICK & BLOCK - THIN BRICK, SAND MOLD SERIES (TIVOLI)CONTACT: RESOURCE BUILDING MATERIALS (949) 855-9994MORTAR: SPEC MIX TYPE #750 SILVERSTONE; JOINT WIDTH: 1/8"
PRINTED TILE PANEL BY VENDOR
DARK BRONZE ALUMINUM
AWNINGS BY VENDOR: FINISH BLACK
EP-2
BK-1
T-4
MF-1
AW-1
PPG - PPG1007-4 HOT STONESTUCCO = EXTERIOR GRADE EGGSHELL FINISHDOORS = EXTERIOR GRADE SEMI-GLOSS FINISH
EP-1
BUILDING PAPER CONTINUES BEHINDMORTAR
EXTERIOR PLYWOODSHEATHING
2X STUD & INSULATION
BRICK VENEER
NOTE: USE @ BRICK VENEER (NOT CMU VENEER)
MORTAR
BRICK VENEER AS OCCURS.
PLYWD. BOTTOM 6"TO BE TREATEDW/ WATERPROOFCOATING
BUILDINGPAPER
P.T. SILL
WEEP SCREED
CONC. SLAB
FINISHED GRADE
1/4" EXPANSION JOINT
CONCRETE SIDEWALK
TYPICAL CONDITION CONDITION AT SIDEWALK
A B
1" M
IN.
4" M
IN.
NAI
LIN
G F
LAN
GE
3 1/
2" M
IN.
PAINTGRAY
MORTAR
MIN
.
1"
MIN
.
2"
1"
REVEAL FINISH:BLACK
7/8" STUCCO
BUILDING PAPER
1/2" PLYWOOD
ATTACH W/ 1/2" SCREWAT TOP & BOTTOM
3/16
".1"
3/16
".7/8"
7/8"
2X FRAMING
PLASTER STUCCO OVER PLYWOODSHEATH (3/8" OR PER STRUCT.
"ZIP STRIP" TO BE REMOVED AFTERAPPLICATION OF PLASTER
"KEENE" PLASTER EXPANSION SCREED- PAINT TO MATCH PLASTER
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A1.50
XXXXX
BID & PERMIT
XX-XX-XX
EXTERIORELEVATIONS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/4" = 1'-0"4
FRONT ELEVATION
1/4" = 1'-0"3
SIDE ENTRY ELEVATION
LEGENDGENERAL NOTES
1. SEAL ALL WALL AND ROOF PENETRATIONS.2. SEE SHEAR SCHEDULE PER STRUCTURAL FOR NAILING PATTERN AND
REQUIREMENTS FOR ALL EXTERIOR GRADE PLYWOOD.3. SEAL ALL WINDOW AND DOOR FRAMES AT HEAD, SILL AND JAMB.4. ALL BUILDING SIGNAGE ARE UNDER SEPARATE PERMIT. LOCATION AND SIZE
OF SIGNAGE TO BE FIELD COORDINATED WITH THE SIGN CONTRACTOR.5. ADDRESS NUMBERS AT 8" HT TO BE ILLUMINATED BY ADJACENT SITE LIGHT
(MINIMUM 5 FOOT CANDLES).6. REFLECTIVE GLAZING AT THE PEDESTRIAN LEVEL IS PROHIBITED. (GLAZING
ABOVE THE PEDESTRIAN LEVEL SHALL BE LIMITED TO MAX. REFLECTANCERATING OF 22% PER NIST). (PER CONDITION 9 OF SDR - 29382)
7. COPING: COPING FLASHING TO BE PAINTED BLACK TO MATCH CANOPIES8. DOOR NOTE: EXTERIOR DOORS & SWITCH GEAR TO BE PAINTED TO MATCH
COLOR OF ADJ. WALL. TYP.9. ANTI-GRAFFITI COATING: ALL EXTERIOR WALLS & DOORS, MEASURED 9'-0" FROM
GRADE, AND ANY WALLS ENCLOSING THE PROPERTY SHALL BE COATEDW/A RENEWABLE COATING OF AN ANTI GRAFFITI MATERIAL.
10. ALL WINDOWS SHALL BE PROVIDED WITH ANTI-GRAFFITI FILM.
KEYNOTE LEGEND - NEW
403 STOREFRONT GLAZING. MULLIONS TO ALIGN WITHCHAIR RAIL ON INTERIOR (TYP).
404 SIGNAGE BY OWNER VENDOR. BLOCKING ANDPOWER BY GC. SEPARATE PERMIT. TYP.
407 NEW LF-12 FIXTURE, TYP. (DARK BRONZE)
408 STOREFRONT GLASS DOOR.
409 NEW LF-14 FIXTURE INTEGRAL WITH MARQUEEBOARD, TYP. COORDINATE WITH VENDOR.
410 MARQUEE BOARD BY OTHERS. GC TO PROVIDEBLOCKING AS REQUIRED.
415 ADDRESS NUMBERS AT 8" HT. PIN-MOUNTEDTHROUGH STUCCO BY GC. BLACK FINISH. FINALLOCATION TO BE APPROVED BY FIRE MARSHALL.
417 FIRST COURSE IS SOLDIER COURSE.
420 BREAK METAL TO MATCH STOREFRONT. FINISH TOCORNER (TYP). AT CANOPY INFILL BETWEEN BOTTOMOF CANOPY AND TOP OF STOREFRONT.
421 TOP COURSE OF TILE TO ALWAYS BE FULL TILE(TYP).
427 EM2 EMERGENCY LIGHT, RE: ELECTRICAL.
512 OUTLINE OF MECHANICAL EQUIPMENT. SEE ROOFPLAN FOR EXACT LOCATIONS. SEE MECH. PLAN FORADDITIONAL INFORMATION.
3" = 1'-0"1
BRICK VENEER
REVISIONS
NO. DATE DESCRIPTION
3" = 1'-0"2
WEEP SCREED 6" = 1'-0"
5TYP. REVEAL
3" = 1'-0"6
STUCCO EXPANSION JOINT
NOTE:CAULK FACE PLATES OF ALL EXTERIOR LIGHT FIXTURES TO PREVENT PEST INFILTRATION.
FIRST FLOOR100' - 0"
2
A1.60
1
A1.60
8
A1.61
6
A1.61
4
A1.61
1
A1.61
EP-1
V.I.F
.
11' -
3"
AR2 AR2
5
A1.41
5
A1.41
5
A1.41
EP-1
EP-1
8' -
0"
T-4AW-1
5
A1.41
412
EP-1
412
BK-1
412407
T-4
409 409
404
404
.
5
A1.50
5
A1.50
BK-1
EP-2
AW1
123' - 5"
EP-1
EQEQ
8' -
0"
EQEQ
8' -
0"
MF-1
BK-1
EQ EQ
403420 420
5
A1.61
410 410
2' -
0".
BOTT
OM
OF
CH
ANN
EL L
ETTE
RS
17' -
0"
10' -
0"
E2 C
RT2RT1
MF-1
5
A1.41
EP-2
3
A1.60
404
EP-1EP-1
EP-2
EP-2
EP-2
5
A1.50
413 TYP2'
- 0"
.
BOTT
OM
OF
CH
ANN
EL L
ETTE
RS
17' -
0"
10' -
0"
425
426
MAU1 RT1 RT2
5
A1.50
PPG - PPG1001-5 DOVER GRAYEXTERIOR GRADE EGGSHELL FINISH
McNear BRICK & BLOCK - THIN BRICK, SAND MOLD SERIES (TIVOLI)CONTACT: RESOURCE BUILDING MATERIALS (949) 855-9994MORTAR: SPEC MIX TYPE #750 SILVERSTONE; JOINT WIDTH: 1/8"
PRINTED TILE PANEL BY VENDOR
DARK BRONZE ALUMINUM
AWNINGS BY VENDOR: FINISH BLACK
EP-2
BK-1
T-4
MF-1
AW-1
PPG - PPG1007-4 HOT STONESTUCCO = EXTERIOR GRADE EGGSHELL FINISHDOORS = EXTERIOR GRADE SEMI-GLOSS FINISH
EP-1
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A1.51
XXXXX
BID & PERMIT
XX-XX-XX
EXTERIORELEVATIONS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/4" = 1'-0"3
DRIVE-THRU ELEVATION
1/4" = 1'-0"2
REAR ELEVATION
LEGEND
KEYNOTE LEGEND - NEW
403 STOREFRONT GLAZING. MULLIONS TO ALIGN WITHCHAIR RAIL ON INTERIOR (TYP).
404 SIGNAGE BY OWNER VENDOR. BLOCKING ANDPOWER BY GC. SEPARATE PERMIT. TYP.
407 NEW LF-12 FIXTURE, TYP. (DARK BRONZE)
409 NEW LF-14 FIXTURE INTEGRAL WITH MARQUEEBOARD, TYP. COORDINATE WITH VENDOR.
410 MARQUEE BOARD BY OTHERS. GC TO PROVIDEBLOCKING AS REQUIRED.
412 NEW LF-13 FIXTURE, TYP.
413 SECURITY LIGHTING FIXTURES, TYP. (BLACK)
420 BREAK METAL TO MATCH STOREFRONT. FINISH TOCORNER (TYP). AT CANOPY INFILL BETWEEN BOTTOMOF CANOPY AND TOP OF STOREFRONT.
421 TOP COURSE OF TILE TO ALWAYS BE FULL TILE(TYP).
425 PREFERRED GAS METER LOCATION. FINALLOCATION TO BE DETERMINED BY GAS SERVICECOMPANY.
426 VENTS REQUIRED FOR UTILITY ROOM.
512 OUTLINE OF MECHANICAL EQUIPMENT. SEE ROOFPLAN FOR EXACT LOCATIONS. SEE MECH. PLAN FORADDITIONAL INFORMATION.
REVISIONS
NO. DATE DESCRIPTION
NOTE:CAULK FACE PLATES OF ALL EXTERIOR LIGHT FIXTURES TO PREVENT PEST INFILTRATION.
ABCDD.1
SUSP
END
ED C
EILI
NG
10' -
6"
B.O
.BEA
M
9' -
0"
DINING
100 507
A1.61
2
B.O. WINDOW/B.O. CANOPY
T.O. PARAPET
T.O. PARAPET
B.2
315
B.O. CANOPY
502
509
RT1
512
EF1
121' - 9"
110' - 0" 110' - 0"
123' - 5"
ABCDD.1
T.O. PARAPET
T.O. MID PARAPET
T.O. PARAPET
503
B.2
315
502
500
501
B.O. CANOPY
RT2
512512
KF4 KF1
512
EF1
512
MAU1
118' - 11 1/8"
123' - 5"
121' - 9"
110' - 0"
T.O. DECAL123' - 11"
2
A1.601
A1.60
8
A1.61
6
A1.61
1
A1.61
507
A5.61
14
DINING
100
A4.11
2
A1.41
9
A1.41
13
12345
315
123' - 5"
T.O. PARAPET
CUSTOMER PICK-UP
101
DINING
100
2' -
10"
9' -
0"
500 501500 501
MAU1EF1
102
TOP TURN BUCKLE
ATTACHED WITH A35 AT EA. END PAD BLOCKING BY G.C.
MIN. 4X WOOD BLOCKING PAD BLOCKING BY G.C.
3/8" X 4-1/2" LAG BOLT(TYP. 4 PER PLATE)
1/4" THICK, 10" X 10"ALUMINUM MOUNTING PLATEWITH WELDED CLIP
3' - 3"
3' - 8".
1" DIAMETERALUMINUM TUBINGSPACING VARIES SEE ELEV.
2" X 2" X 1/8"ALUMINUM
MOUNTING ANGLE
10 1
/2".125" ALUMINUM
FORMED CANOPY@10-3/8" X 2"
CHANNELOPEN AWING, NO COVER
(40.0" AT DRIVE - THRU)
2' - 10" OR 2' - 6 1/2" OR 3' - 7/8"
7 1/
2"
#10 X 5/8"PHILIP PAN HEADTEK SCREW TYP.
2' -
6" T
O C
ENTE
R O
F C
LIP/
PLAT
E
MIN, 4X WOOD BLOCKING W/ A35CONNECTOR AT BOTH ENDS OF STUD. BY G.C.
0125" ALUMINUM FORMED CANOPY @ 10" X 2" STRUT
MAX. SPACING 24".PROVIDED BY
AWNING VENDOR.
#10 X 5/8"PHILIP PAN HEADTEK SCREW TYP.
3/8" X 4-1/2" LAG BOLT(TYP. 4 PER BLK'G)
MIN, 4X WOOD BLOCKING W/ A35CONNECTOR AT BOTH ENDS OF STUD. BY G.C.
AWING CONNECTION
EXTERIORZIP WALL SYSTEM, RE: SPECS
FINISH. SEEELEV. SCHEDULE
2X STUD PERPLAN
R-19 BATT.INSULATION.SEE SPEC.(TYP.)
ANCHOR BOLTPER STRUCT.DWG.FLASHING TO
PROTECT BASE
SNAP GAP SEALANT
110' - 6"110' - 0"
AWNING BY VENDOR
2X BLOCKING
1/2" PLYWOODPRINTED TILE PANEL BY VENDOR
WOOD BEAM. RE: STRUCTURE.
MOISTURE BARRIER
FLASHING
SEALANT
BRAKE METAL, MATCH STOREFRONT
SEALANT
GC TO PROVIDE BACKING AS NEEDED PER OWNER'S VENDOR SHOP DRAWINGS
SUBSTRATE AND FINISH TO RUN BEHIND CANOPIES, TYP
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A1.60
XXXXX
BID & PERMIT
XX-XX-XX
SECTIONS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/4" = 1'-0"2
BUILDING SECTION 2
KEYNOTE LEGEND - NEW
315 ROOF HATCH. RE: SPECS.
500 ROOF MEMBRANE SOLAR REFLECTANCE OF 0.70 AND MIN THERMALEMITTANCE OF 0.75 WHEN TESTED.
501 5" RIGID INSULATION.
502 ROOF TRUSSES. RE: STRUCTURAL.
503 DECORATIVE WOOD CUT TILES.
507 SEE STRUCTURAL DRAWINGS FOR FOUNDATION AND CONCRETESLAB.
509 BATT INSULATION.
512 OUTLINE OF MECHANICAL EQUIPMENT. SEE ROOF PLAN FOR EXACTLOCATIONS. SEE MECH. PLAN FOR ADDITIONAL INFORMATION.
1/4" = 1'-0"1
BUILDING SECTION 3
1/4" = 1'-0"3
BUILDING SECTION 1
REVISIONS
NO. DATE DESCRIPTION
1" = 1'-0"5
AWNING
1" = 1'-0"7
BASE
1 1/2" = 1'-0"6
AWNING DETAIL @ STOREFRONT
FIRST FLOOR100' - 0"
A B C D D.1
T.O. LOW PARAPET122' - 5"
3
A1.61
A1.61
6
3
A1.60T.O. BRICK PARAPET
B.2
A1.61
5
512
RTU1
STUCCO
MEMBRANE ROOFING OVER 1/2" PLYWD.
6" WOOD STUDS
CANOPY BY VENDOR (N.I.C.) TYP.
SEE STRUCT FOR PSL BEAM SIZE
SUSPENDED CEILING
A1.41
5
DINING
100
A6.01
8
CONCRETE FOOTING & SLAB. RE: STRUCTURE.
A1.60
6
A1.41
2
STOREFRONT
CONTROL JOINT
ROOF TRUSS. RE: STRUCTURE.
1
100' - 0"
T-4 PANEL BY VENDOR
STO
REF
RO
NT
10' -
0"
110' - 6"
FLASHING
ZIP WALL SYSTEM, RE: SPECS
A
EXTERIOR SMOOTH STUCCO OVER METAL
LATH
BATT INSULATION
AIR/ MOISTURE BARRIER
A1.41
5
A1.41
2ZIP WALL SYSTEM
RE: SPECS
6" WOOD STUD
MARQUEE BOARD BY VENDOR. PROVIDE
BLOCKING AS REQUIRED. COORDINATE WITH
VENDOR FOR LOCATION
A1.60
7
CONCRETE FOOTING & SLAB. RE: STRUCTURE.
ROOF TRUSSES. RE: STRUCTURE.
MEMBRANE OVER 1/2" PLYWOOD.
CONTROL JOINT
4" RIGID INSULATION
STORAGE
106
SEE PLUMBING PLANS FOR
BEVERAGE & SALSA BAR DRAINAGE
6" WOOD STUDS
3 5/8" 20 GA. STUD @ 16" O.C.
BATT INSULATION TYP. AT EXTERIOR
WALLS
A1.41
5
A1.41
2
A1.60
7
CONCRETE FOOTING & SLAB. RE: STRUCTURE.
STUCCO
WOOD TRUSSES RE: STRUCTURE
4" RIGID INSULATION
ZIP WALL SYSTEM,
RE: SPECS
CONTROL JOINT
2X WOOD CANT
1/2" PLYWOOD SHEATHING
RUN ROOFING MEMBRANE UP WALL AND UNDER PARAPET CAP (TYP)
SALSA BAR
100a
FIRST FLOOR100' - 0"
AWNING BY VENDOR (N.I.C.). GC TO PROVIDE ALL REQUIRED BLOCKING FOR OWNER VENDOR INSTALL
WOOD BEAM. RE: STRUCT.
BATT INSULATION TYP. AT EXTERIOR WALLS
1/2" PLYWOOD SHEATHING
A1.41
5
A1.41
2
DK BRONZE ANODIZED STOREFRONT
T-4 PANEL BY OTHERS
AIR/MOISTURE BARRIER
6" WOOD STUD
ROOF ASSEMBLY
ROOF TRUSSES. RE: STRUCTURE.
CONCRETE FOOTING & SLAB. RE: STRUCTURE
A6.01
7
CONTROL JOINT
1" INSULATED GLAZING TEMPERED WHERE REQUIRED
A6.01
8
VAPOR BARRIER
118' - 11"
BRAKE METAL, MATCH STOREFRONT
B
A6.01
7
A6.01
8
BRICK VENEER
PROVIDE BLOCKING AS REQ. COORDINATE WITH VENDOR FOR PLACEMENT & SIZE.
WOOD TRUSS RE: STRUCTURE.
RUN ROOF MEMBRANE UP PARAPET WALL 24"
SIGNAGE BY VENDOR. SEPARATE PERMIT. TYP
A1.41
2
A1.41
5
DINING
100
STOREFRONT. RE: SPECS.
EXTERIOR LIGHTING. RE: MEP
AWNINGS BY VENDOR (N.I.C.)
6" WOOD STUDS.
ZIP WALL SYSTEM, RE: SPECS
FLASHING
CONCRETE FOOTING & SLAB. RE: STRUCTURE.
BATT INSULATION
123' - 5"
CONTROL JOINT
1/2" PLYWOOD DECK
2X WOOD CANT
4" RIGID INSULATION
2' -
0"
CONTINUOUS SEALANT BETWEEN STOREFRONT AND MASONRY
RETURN BRICK TO STOREFRONT
A1.60
6
110' - 0"
T4 PRINTED TILE PANEL BY OTHERS
STOP FLASHING
PLYWOOD AS REQUIRED FOR SIGNAGE.
COORDINATE LOACTION WITH VENDOR
D.1
STUCCO
DRIVE-THRU WINDOW
CONCRETE FOOTING & SLAB. RE: STRUCTURE.
WOOD HEADER RE: STRUCTURE
CANOPY/ AWNING BY VENDOR (N.I.C.) TYP.PROVIDE BLOCKING AS REQ. COORDINATE WITH VENDOR FOR PLACEMENT & SIZE. TYP.
AIR/ MOISTURE BARRIER
6" WOOD STUD
ROOF TRUSSES. RE: STRUCTURE.
PLYWOOD SHEATHING
ROOF MEMBRANE. CONTINUE UP PARAPET WALL AND UNDER PARAPET CAP
2X CANT
FLASHING
CONTROL JOINT
FLASHING AND SEALANT
ZIP WALL SYSTEM, RE: SPECS
6" WOOD STUD FRAMING
STUCCO
RETURN STUCCO TO WALL. SEAL
BETWEEN STUCCO AND TILE
BATT INSULATION TYP. AT EXTERIOR WALLS
4" RIGID INSULATION
A1.41
5
FLASHING
A1.41
2
A1.60
6
A5.63
6
A1.60
7
T-4 PANEL BY VENDOR
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A1.61
XXXXX
BID & PERMIT
XX-XX-XX
SECTION & WALLSECTIONS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/4" = 1'-0"8
BUILDING SECTION 4
1/2" = 1'-0"3
WALL SECTION @ DINING 1/2" = 1'-0"
6WALL SECTION @ B.O.H
KEYNOTE LEGEND - NEW
512 OUTLINE OF MECHANICAL EQUIPMENT. SEE ROOF PLAN FOREXACT LOCATIONS. SEE MECH. PLAN FOR ADDITIONALINFORMATION.
1/2" = 1'-0"4
WALL SECTION @ SALSA BAR 1/2" = 1'-0"
1WALL SECTION @ ENTRANCE
1/2" = 1'-0"2
WALL SECT. @ DINING
REVISIONS
NO. DATE DESCRIPTION
1/2" = 1'-0"5
WALL SECTION @DRIVE THRU
A3.10
4
A3.10 12
13
9
10
6
7
3
A3.10
5
8
TA-2
TA-2
TA-8
TA-12 TA-8
TA-4
1' - 6"
TA-6
1' - 6"
8' - 4"
7' -
9 1/
2"
TA-10
1' - 6"
MAX
6"
MIN
3' - 0"
MIN
3' -
6"
MAX
1' -
0"
TA-1
TA-1
1' -
6 1/
2"
TA-1 TA-3 TA-1TA-10
TA-3
TA-4
TA-6
MIN
3' -
0"
MA
X
6"
5' -
3"5'
- 0"
1' -
6"
1' - 6" 1' - 6 1/2"
8' - 3 1/2" MIN
3' - 6"
MAX
1' - 0"
WOMENS
110
MENS
111
TA-4
1. FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE TIGHT GASPING, PINCHING, OR TWISTING OF THE WRIST AND SHALL BE MOUNTED NO MORE THAN 44 INCHES ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS PER FOOT.
2. TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE TIGHT GASPING, PINCHING OR TWISTING OF THE WRIST. CONTROLS FOR THE FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF THE TOILET AREAS, NO MORE THAN 44 INCHES ABOVE THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS PER FOOT. (TYPICAL)
3. THE HARDWARE ON "BOTH SIDES" OF THE ACCESSIBLE WATER-CLOSET PLUMBING FIXTURE'S STALL/ COMPARTMENT PARTITION SWING DOORS HAS OPEN LEVER ACTION AND/ OR U-SHAPED TYPE WIRE-PULL HANDLES, THAT DO NOT FORCE PEOPLE WITH DISABILITIES TO HAVE TO TIGHTLY GRASP AND/ OR TWIST TO OPEN/ CLOSE THE DOOR.
4. WALL-MOUNTED TOILET ACCESSORIES THAT MIGHT ENCROACH MORE THAN 4" INTO THE REQUIRED CLEAR FLOOR SPACES (CFS) OF THE ACCESSIBLE PLUMBING FIXTURES (SUCH AS OVERHEAD WALL-MOUNTED STORAGE CABINETS LOCATED ABOVE ACCESSIBLE WATER CLOSET FIXTURES, PAPER TOWEL DISPENSERS, AUTOMATIC ELECTRIC HAND-DRYERS, ETC. - CLEAR FROM FINISHED FLOOR TO 80" AFF), COAT HOOKS MOUNTED ON THE TOILET PARTITION DOORS OF THE ACCESSIBLE STALL (HIGHLY SUGGEST PLACING THE HOOK SOMEWHERE ELSE INSIDE THE STALL - NOT ON THE CLOSING DOOR - RIGHT AT KID'S EYE HEIGHT), SHOWER CURTAIN RODS INCORRECTLY MOUNTED BELOW 80", MORE THAN 4" DEEP DEFIBRILLATOR CABINETS, ECT. THAT MAY BE HAZARDS ALONG ACCESSIBLE ROUTES (AS MAY BE APPLICABLE).
5. OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM.
6. WATER CLOSETS AND TOILET COMPARTMENTS SHALL COMPLY WITH 604.2 THROUGH 604.8. PLEASE VERIFY COMPLIANCE ACCORDINGLY PRIOR TO THE REQUIRED ON-SITE ACCESSIBILITY/ USABILITY INSPECTION.
7. DOOR AT MEN'S RESTROOM TO HAVE A PRIVACY LOCKS AND SELF CLOSER. (WOMEN'S RESTROOM LESS PRIVACY LOCK). ACCESSIBLE TOILET COMPARTMENT DOORS WILL HAVE AT LEAST 34" CLEAR OPENING. FLUSH VALVES ON WIDE SIDE OF WATER CLOSETS.
8. FOR ADDITIONAL RESTROOM CLEARANCE INFORMATION SEE SHEET CS0.10.
ALL ACCESSORIES LISTED BELOW TO BE SUPPLIED & INSTALLED BY GENERAL CONTRACTOR, UNO.
MIN9"
7
A5.10
PT-3
TA-11TA-10
TL-7
10"X34" KICKPLATE
PL-4
7
A5.10
42"
WALL BACKING BEHIND GRAB BARS, TYP
TA-1 TA-2 TA-3
TL-7
TA-8
A3.10
2
TA-4
7
A5.10
TA-4
TA-2
TA-1
TA-3
TA-6
TL-7
PL-4
TA-8
TL-7
7
A5.10
TA-1
TA-2
TL-7
TA-8
7
A5.10
TA-1
TA-2
A3.10
2
TA-6
TL-7
2
A3.10
7
A5.10
TA-10
TA-6
TL-7
7
A5.10
PT-3
STAINLESS STEEL ANTI-GRAFFITI ON MEN'S DOOR ONLY
TL-7
10"X34" KICKPLATE
BRAILLE SIGN REF 3/CS0.10
PL-2
PT-5
PT-4
10"X34" STN. STL. KICKPLATE
CS0.10
4
TL-11
PT-4
PT-5
PL-2
CS0.10
4BRAILLE SIGN REF 3/CS0.10
10"X34" STN. STL. KICKPLATE
TL-11
HARDWARE PROVIDED PERMANUFACTURE, KOALACARE-KB200 BABYCHANGING STATION. SIX 1/4"X 3" LONG SCREWS
2X BLOCKING
HARDWARE PROVIDED PERMANUFACTURE, KOALACARE-KB200 BABYCHANGING STATION. SIX 1/4"X 3" LONG SCREWS
2X BLOCKING
FLOORMAX. WT. 60 LBS
TOP
(2)
SC
REW
SAT
42
1/4"
TO
MEE
T AD
A H
T.R
EQ. 2X BLK'G
TYPICAL
GYP. BRD.
WALL TILE FINISH
F.F.
NOTE:1. ACCESSIBLE TOILET COMPARTMENTS CANNOT BE OBSTRUCTED BY CHANGING
TABLE IN EITHER AN OPEN OF CLOSED POSITION. PER TAS 604.8.1.1
2. CLEAR FLOOR SPACE REQ. FOR CHANGING TABLE MAY OVERLAP THE WATERCLOSET CLEARANCE BASED ON TAS 604.3.2 PER ADVISORY 604.8.1.1
3 3/
4".
4 1/
2".
5 1/
2".
16".
LINER DISPENSER DIMENSIONS WHEN ATTACHED
19 11/16".
+/- 20"
FRO
M F
.F.
31".
+/-1
4"
35 3/16".RE
ACH
40" M
AX.
KNEE
CLR
.
33" M
IN.
9" M
IN.
27" M
IN.
8" MIN.
29" M
IN.
34" M
AX.
40" M
AX.
6" MAX.
17" MIN.
74" M
IN.
ADA PIPE COVER
FIXTURE & ACCESSORY MOUNTING HEIGHTS 1/4" = 1'-0"
STANDARD MOUNT PAPER TOWEL DISPENSER
1' -
10"
1' -
0"3'
- 6"
1' -
5"
URINALS
MIN 30" CLR BETWEENURINAL SCREENS TYP. STANDARD URINAL 22" TO RIM ADA URINAL 17" TO RIM
1' - 6"
3' -
6"1'
- 0"
URINAL DIVIDER WITHFULL HEIGHT WALLBRACKET & END FLOOR SUPPORT
STANDARD STALL STANDARD STALL LAYOUT ADA STALL LAYOUT ADA STALL LAYOUT
CLR.
3' - 0"
1' -
3" T
O R
IM
EQ. EQ.TOILET PARTITION
TA-4
TA-2
TA-3
TOILETPARTITION
TA-4
TA-2
TA-3
2' -
10"
2' -
8"
7" 4"
C/L
2' - 8" TOCLR.
5' - 9"
3' - 5" TO C/L
48" M
AX.
15" M
IN.
1' -
5"2' -
8"
1' -
5"
7" TO 9"
12" MAX
TA-3TA-2
TA-1
TA-1TA-1 TA-4
NOTE: FLUSH HANDLE LOCATEDON "WIDE" SIDE OF STALL. TYP. ATALL ACCESSIBLE LOCATIONS
TA-1
TA-4
TA-1TA-1TA-3TA-2
ACCESIBLE STALL
16" TO 18"ADA STALL
NOTE: INSTALLER TO REFER TO & COMPLY WITH ALL LOCAL CODES/ ANSI REGULATIONS WHEN SETTING OUT ALL ACCESSIBLE TOILET ROOM ACCESSORIES. THESE WILL SUPERSEDE ANY DIMENSIONS SHOWN ON PLANS. REFER TO TOILET ACCESSORY SCHEDULE FOR ADDITIONAL INFORMATION. MOUNT COAT HOOKS IN ALL STALLS, MOUNT 48" MAX.A.F.F. IN ADA STALLS
MIN.
1' - 0" 6"
2' -
8" 1' - 8 1/2"
4"
4' -
1 1/
4"
9 1/
2"2'
- 11
1/2
"
1' - 8 1/2"
1' - 4"
3' - 0 1/8"
HORIZONTAL BABY CHANGING STATION
TA-10
AMBULATORY STALL
17" TO 19"
ADA RECESS
3' -
1"DEPTH
COORDINATE RECESS
4" MAX
AMBULATORY STALL LAYOUT AMBULATORY STALL LAYOUT
TA-4
TA-2TA-3
48" M
AX.
15" M
IN.2'
- 8"
12" MAX.
CLR.
5' - 9"
1' -
5"
7" TO 9"
NOTE: FLUSH HANDLE LOCATEDON "WIDE" SIDE OF STALL. TYP. ATALL ACCESSIBLE LOCATIONS
TA-1
1' -
5"
TA-4
TA-1TA-3TA-2
ACCESIBLE STALL
16" TO 18"
AMBULATORY STALL
17" TO 19"
TA-1
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A3.10
XXXXX
BID & PERMIT
XX-XX-XX
ENLARGED RRPLAN & DETAILS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/2" = 1'-0"1
ENLARGED RESTROOM PLAN
RESTROOM NOTES
TAG DESCRIPTION MFG./MODEL REMARKS
TA-1 GRAB BAR BORICK #B-6806 (24",36", 42")
TA-2 TOILET PAPERDISPENSER
BORICK #B-2888 STAINLESS STEEL. FLUSHMOUNTED IN CALIF.
TA-3 SANITARY NAPKINDISPOSAL
BOBRICK #B-270 STAINLESS STEEL, SURFACEMOUNTED/ FLUSH MOUNTED INCALIF.
TA-4 DISPOSABLE SEATCOVER DISPENSER
BOBRICK #B-221 STAINLESS STEEL, SURFACEMOUNTED
TA-6 LIQUID SOAPDISPENSER
MBM STAINLESS STEEL
TA-7 1/4" POLISHED PLATEGLASS MIRROR 18" x36" ANTI - GRAFFITI
CENTURY MIRROR(661) 251 8059 / SMS1836
WOMEN'S ONLY
TA-8 PAPER TOWELDISPENSER
MBM
TA-9 BOBRICK BOBRICK CLASSICSERIES #1542
TOILET PARTITIONS (LEAD TIMEITEM)
TA-10 BABY CHANGINGSTATION
KOALA CARE/KB200-00 CREAM
SEE THIS SHEET FORMOUNTING REQUIREMENTS
TA-11 COMTEC #HADPZ CHROMEPLATED ZAMAKDOOR PULL FORHANICAPPED &AMBULATORYSTALLS ONLY
DOOR PULL FOR ACCESSIBLE &AMBULATORY STALLS ONLYINSTALL BOTH SIDES OF DOOR
TA-12 COAT HOOKS BOBRICK STAINLESS STEEL. SURFACEMOUNTED/ FLUSH MOUNTED INEVERY STALL.
1/4" = 1'-0"9
WOMEN'S RESTROOM-A
1/4" = 1'-0"10
WOMEN'S RESTROOM-B
1/4" = 1'-0"12
WOMEN'S RESTROOM-C
1/4" = 1'-0"13
WOMEN'S RESTROOM-D
1/4" = 1'-0"3
MEN'S RESTROOM-A
1/4" = 1'-0"4
MEN'S RESTROOM-B
1/4" = 1'-0"6
MEN'S RESTROOM-C
1/4" = 1'-0"7
MEN'S RESTROOM-D
1/4" = 1'-0"5
VESTIBULE-A 1/4" = 1'-0"
8VESTIBULE-B
NOTE:TOILET TISSUE DISPENSERS THAT CONTROL DELIVERY OR THAT DO NOT PERMIT CONTINUOUS PAPER FLOW SHALL NOT BE USED. SEE ENLARGED PLAN THIS SHEET FOR ADDITIONAL ACCESSORY INFO
N.T.S.11
BABY CHANGING TABLE DETAILSN.T.S.
2SINK DETAIL
REVISIONS
NO. DATE DESCRIPTION
SUPPLY
GC
INSTALL
GC
GC GC
GC GC
GC GC
OWNER GC
OWNER GC
OWNER GC
GC GC
GC GC
GC GC
GC GC
A
B
C
D
D.1
109' - 0"
CL-4, PT-4
CL-1, PT-4
109' - 2"
SOFFIT HT
B.O.WD. TRIM
TILES
109' - 0"
CL-4, PT-5108' - 0"
CL-2
108' - 0"
CL-2
2
A1.60
1
A1.60
8
A1.61
1
A1.61
204
204
212
110' - 6"
CL-1, PT-4
KITCHEN VENDORTO SUPPLY S.S. FILLER
14
A5.61
8
A4.11
8
A4.11
3
A1.60
DINING
100
A4.11
1
4' -
1"16
' - 7
"
201
204204
109' - 2"
CL-2
1 2 3 4 5
B.2
4' -
1"
CO
OR
DIN
ATE
EXAC
T SI
ZE &
LO
CAT
ION
W/ V
END
OR
26' -
2 1
/2"
6' -
1 1/
2"
W-3
109'-8"
4' - 9 1/2"
COORDINATE EXACT SIZE & LOCATION W/ VENDOR
16' - 11" 4' - 10"
206
210
3' -
3 1/
2"
5' - 6"
1' -
8"
212
OFFICE
105 WATER HEATER
114
WOMENS
110MENS
111
109' - 0"
CL-2
201
206
206
COOLER
107
STORAGE
106
SALSA BAR
100a
CUSTOMER PICK-UP
101
VESTIBULE
113
5
A1.61
17 5
/8".
1' -
5 1/
2"EQ
EQEQ
EQEQ
EQEQ
EQEQ
EQ
3' -
1"2' -
4"
3' - 2 1/2" 4' - 5 1/2"
1' -
10 1
/2"
5' -
0 1/
2"5'
- 0
1/2"
5' -
0"1'
- 9
1/2"
1' - 5"
1' - 3 1/2"
3
A4.11
109' - 2"
CL-1, PT-3
220
CO
OR
DIN
ATE
EXAC
T SI
ZE A
ND
LO
CAT
ION
W/ V
END
OR
20' -
4 1
/4"
1' -
2 3/
4"1'
- 1
1/8"
1' - 4" 1' - 9 1/2" 1' - 4" 2' - 7 5/8"
1010' - 6"
CL-1, PT-1
W-3
109'-10"
222
COORDINATE EXACT SIZE AND LOCATION W/ VENDOR
6' - 3 3/8".
222
222
222
222
1. CONTRACTOR SHALL VERIFY FIXTURE QUANTITIES & ALSO MAKE PROPER ADJUSTMENTS FOR ANY CHANGES IN PLAN DUE TO ADDITIONAL REQUIREMENTS, LOCAL CODES ETC.
2. LIST FOR MATERIALS, SPECIFICATIONS SEE FINISH SCHEDULE AND FINISH MATERIALS & ADDITIONAL INFORMATION ON SHEET A6.10.
3. FOR H.V.A.C. PLAN, SECTIONS, DUCT LOCATIONS, SUPPLY AND RETURN AIR GRILLE SIZES AND ADDITIONAL INFORMATION SEE SHEET MECHANICAL DRAWINGS.
4. ALL FIXTURES SHALL BE LOCATED IN CENTER OF CEILING TILES UNLESS OTHERWISE NOTED.5. SEE MEP DRAWINGS FOR LIGHTING LAY-OUT REQUIREMENTS & ADDITIONAL INFORMATION.6. CONTRACTOR TO COORDINATE PENDANT LIGHT LOCATIONS.7. SEE ELECTRICAL DRAWINGS FOR LIGHTING CIRCUITS AND SWITCHING.8. CENTER EXIT SIGNS OVER DOOR OPENINGS AND CEILING FIXTURES IN GRID SPACES WHERE
POSSIBLE.9. WALK - IN COOLER FLUORESCENT LIGHTING PROVIDED AND INSTALLED BY ELECTRICAL
CONTRACTOR.10. SHATTER SHIELDS FOR ALL LIGHTS ABOVE FOOD PREP, WORK AND STORAGE AREAS SHALL BE
PROVIDED.11. PRIOR TO INSTALLATIONS, A SAMPLE OF CEILING TILE IS TO BE SUBMITTED TO ENVIRONMENTAL
HEALTH FOR APPROVAL.12. FOR MONITOR MOUNTING SEE DETAIL A5.61.13. ALL DIMENSIONS TO FACE OF STUDS.14. PROVIDE 'SS' CLOSURE FLASHING BETWEEN TOP OF HOODS & CEILING. TYP.15. SEE EXTERIOR ELEVATIONS FOR EXTERIOR WALL SIGNAGE.16. FOR FINISH/MATERIAL SCHEDULE SEE SHEET A6.0017. WALL AND CEILING SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS PER IBC 201218. EXIT ILLUMINATION PER IBC 201219. THE LIGHTING MUST PROVIDE A MINIMUM OF ONE - FOOT CANDLE AT THE FLOOR LEVEL
THROUGHOUT THE EXIT PATH. TESTING OF THE FIXTURES WILL BE REQUIRED AT FINAL INSPECTION. THE FIRE INSPECTOR MAY REQUEST A NIGHTTIME TEST AT HIS DISCRETION TO CONFIRM THE MINIMUM REQUIREMENT OF ONE - FOOT CANDLE AT FLOOR LEVEL.
ITEM SYMBOL DESCRIPTION
UNIVERSAL LED EDGE-LIT EXIT SIGN
AIR SUPPLY DIFFUSER
ADJUSTABLE DOWNLIGHT W/ REFLECTOR KIT
ADJUSTABLE DOWNLIGHT
RECESSED LED TROFFER
EM HEADLIGHT
DECORATIVE PENDANT
DECORATIVE SWAG CHANDELIER
DECORATIVE PENDANT
EXTERIOR SCONCE
EXTERIOR DECORATIVE LIGHT PENDANT
EXTERIOR DOWN LIGHT FOR ARTWORK
EXTERIOR RECESSED LED
EMERGENCY LIGHT
EXTREME ENVIRONMENT LENSED & GASKETED FIXTURE
EXTERIOR MOUNTED LIGHT FIXTURE
LF-2
LF-1
LF-3
EM-2
LF-9
LF-10
LF-12
LF-13
LF-14
LF-16
EM-1
LF-20
EX-1
LF-5A
LINEAR RECESSED MENU BOARD LIGHTING
SURFACE MOUNTED STRIP LIGHTLF-19
EXTERIOR LIGHTINGLF-15
LF-17
DISPLAY SPOTLIGHT
LF-6 DECORATIVE STRIP LIGHTING
LF-7
LF-8
LF-11A DECORATIVE PENDANT
LF-11B DECORATIVE PENDNT
LF-21 RECESSED LED TROFFER
LF-22 SURFACE MOUNTED STRIP LIGHT
ALL THREADSUPPORT PER DETAIL 2/A1.40
5/8" TYPE 'X' GYP. BD.BOTH SIDES
2x STUDS-SIZE & SPACINGPER PLAN
STAINLESS STEEL HOOD-PERMECHANICAL PLAN SHT. M1
TOP OF HOOD
1" SHT. MTL. SCREWS AT 16" O.C.
5 1/4" x 3/8" LAG BOLT W/1" O.D. WASHER
GALV. HAT CLIP SPACERCONTINUOUS AT BACK OF HOOD& SIDE WHERE HOOD ABUTS WALL.
4x6 BLOCKING - ATTACH TOSTUDS W/ AS REQUIRED FORHAT CLIP BACKING
1/4" BEND W/2-1/2" MB
TOP CHORD OF TRUSS
DOUBLE 2x BLOCKING BETWEENTRUSSES - USE SIMPSONPF26A HANGERS
1/4"x3"x3" METAL ANGLE 6" LONGATTACHED W/ (2) 1/2" DIA. BOLTS
1/2" ALL THREAD W/DOUBLENUTS AT EACH END
HOOD
EXISTING CHANNEL BY HOODMANUFACTURER
SEISMIC CABLES (TYP. @ ALLCORNERS)
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A4.10
XXXXX
BID & PERMIT
XX-XX-XX
REFLECTEDCEILING PLAN
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/4" = 1'-0"3
REFLECTED CEILING PLAN
GENERAL NOTES
KEYNOTE LEGEND - NEW
201 GC TO PROVIDE J-BOXES FOR CANOPY AND J-BOXES FORSIGNAGE.
204 FOR SUSPENDED CEILING SEE DETAIL 6, 7 & 9/A4.11.
206 BULKHEAD AT 7'-0" INTERIOR AND AT 10'-0" ATSTOREFRONT.
210 EXHAUST HOOD.
212 AIR CURTAIN TO BE DOOR ACTIVATED.
220 CONTINUE CEILING TILE UNDER DECORATIVE BEAMS.PAINT GRID AND TILE BLACK WITHIN FOAM BEAMS.
221 FOAM BEAM BY VENDOR.
222 CEILING-MOUNTED MONITOR RE: K-DRAWINGS.
1" = 1'-0"1
HOOD CONNECTION 1 1/2" = 1'-0"
2HOOD ATTACHMENT
REVISIONS
NO. DATE DESCRIPTION
+ 11' - 2"B.O. TRUSS
+ 9' - 2"+ 9' - 2"
B.O. SOFFIT
ENTRY CEILING FEATURE BY VENDOR, INSTALLED BY VENDOR
CL-1CL-1
6' - 3 3/8".
GRID-TO-GRID
6' - 0"
T-GRIDPIN WHEEL BY VENDOR
SINGLE TRACK LIGHTING RE: ELEC.
2' - 0" 2' - 0" 2' - 0"
T-GRID
WOOD TRIM BY VENDOR
PT-4
PT-4
A4.11
3
2
A4.1110
' - 1
" VER
IFY
IN F
IELD
VERIFY IN FIELD
2X2 LAY-IN CEILING
PIN WHEEL PANELS BY VENDOR
PREFERRED NO VISIBLE CONNECTORS
EQ
20' - 4 1/4".
EQ6'
- 3
3/8"
.EQ
GYP BD OVER SALSA BAR
3' - 5"
EQ
CEILING GRID TO ALIGN W/ WOOD TRIM
PT-4
PT-3
LAY-IN CEILING AND GRID; PAINT PT-4 THIS SIDE OF BEAM
FAUX BEAM COVER BY VENDOR
4X8 LIGHTWEIGHT FAUX WOOD BEAM. ATTACHMENT BY VENDOR
+ 9' - 10"
+ 9' - 8"
+ 10' - 6"
+ 11' - 0"
B.O. TRUSS
NO CORNER BEADS WHERE FAUX FOAM BEAM OCCURS. TYP.
TRANSITION FROM GRAY TO BLACK CEILING TILES TO OCCUR UNDER FAUX BEAM
BLOCKING BY VENDOR
CONECTIONN.T.S.
A
A2X BLOCKING BY VENDOR
ALL-THREAD ATTACHED TO UNISTRUT BY G.C.
LAY-IN CEILING AND GRID, PAINT PT-1
ALL-THREAD ATTACHED TO UNISTRUT BY G.C.
LAY-IN CEILING AND GRID; PAINT PT-1 THIS SIDE OF BEAM
1" MIN
.
3-1 1/2" X 9 GA. STAPLES OR3 STRONG HOLD 'U' NAILSAT EA. WIRE LOOP
ROOF STRUCTURE
WIRE HANGER OR BRACE(TYPICAL)
ROOF STRUCTURE
1/4" EYE SCREW W/ MIN.1 1/4" PENETRATION
CEILING GRIDMAIN RUNNER
3"MAX.
12 GAGE WIRE ATDIAGONAL CORNERS(STRUNG TIGHT-NOTENSION) FOR LIGHTFIXTURE SUPPORT TOSTRUCTURE
12 GAGE VERTICALSUSPENSION WIREAT 12'-0" O.C.
RECESSED LIGHTFIXTURE HOUSING
CEILING GRIDMAIN RUNNER
12 GAGE WIRE AT DIAGONAL CORNERS
UNDERSIDE OFSTRUCTURE
(1) LAYER5/8" TYPE "X"W.R. GYP.GYPSUM BOARD
2"ANGLE SUPPORT
6"
CONTINUOUS FRPJ-TRIMFINISH PERFINISH SCHEDULE
NOTE: CEILING AREAS GREATER THAN 2,500 SQUARE FEET SHALL BE BROKEN INTOAREAS NOT EXCEEDING 2,500 SQUARE FEET SEPARATED BY EITHER FULL- HEIGHTPARTITION WALLS OR SEISMIC JOINTS THAT ARE A MINIMUM OF 1.5 INCHES WIDE.
EACH AREA SHALL BE SEISMICALLY RESTRAINED, (ASCE 7 SECTION 13.5.6.2.2, ITEM D)
BOTTOM CHORDOF ROOF TRUSS
PROTECT SYRUP LINESFROM TRUSS ANGLES
BUNDLED SYRUP LINES
NOTE:SYRUP BUNDLE SUPPLIED BY K.E.C. & INSTALLED BY SODA VENDOR
+ 9' - 0"
CL-1
PT-4
+ 9' - 2"
T-GRID
CEILING ENTRY FEATURE PROVIDED AND INSTALLED BY VENDOR
WOOD TRIM BY VENDOR
GYP BD
3 1/2" METAL STUDS
PT-4
T-BAR PERMIMETER ANGLE
5/8" REVEAL BEAD PAINTED TO MATCH CEILING
W-3
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
TKa r c h i t e c t s
I
®™N T E R N A T I O N A L
____________________________
PROJECT #
SHEET NUMBER
A4.11
XXXXX
BID & PERMIT
XX-XX-XX
REFLECTIVECEILING PLAN -
DETAILS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1" = 1'-0"2
SECTION - ORDER AREA CEILINGPANELS
1/2" = 1'-0"1
PARTIAL REFLECTED CEILING PLAN -ORDER AREA CEILING PANELS
3" = 1'-0"8
DETAIL - WOOD BEAM AT DININGSOFFIT
3" = 1'-0"6
GRID SUSPENSION
1/2" = 1'-0"7
SUSPENDED FIXTURE
3" = 1'-0"9
CEILING TO PARTITION WALL
REVISIONS
NO. DATE DESCRIPTION
3/4" = 1'-0"5
SYRUP LINES IN CEILING
3" = 1'-0"3
SALSA BAR SOFFIT
TL-5
TL-3
TL-5
TL-3
C-1
DINING
100
A5.10
6
A5.10
6
A5.10
6
A5.10
6
A5.10
6
A5.10
3
A5.10
6
A5.10
6
5
A5.10
4
A5.10
12
A5.61
703703
703703
TL-3
9
A5.10
9
A5.10
9
A5.10
A5.10
6
A5.10
6
A5.10
6
A5.10
6
A5.10
6
A5.10
6
A5.10
6
A5.10
6A5.10
6
SALSA BAR
100a
CUSTOMER PICK-UP
101
COOLER
107
STORAGE
106
OFFICE
105
WOMENS
110
MENS
111
VESTIBULE
113
WATER HEATER
114
701700
704
700
711
711
TYP TYP
TYP
TL-11
CUT BASE
TL-11
CUT BASE
TL-11
CUT BASE
TL-11
CUT BASE
TL-11
CUT BASE
TL-11
CUT BASE
TL-11
CUT BASE
TL-5
CUT BASE W/ SCHLUTER COVE
TL-5
CUT BASE W/ SCHLUTER COVE
TL-5
CUT BASE W/ SCHLUTER COVE
TL-11
CUT BASE
TL-11
CUT BASE
TL-11
CUT BASE
TL-11CUT BASE
710710
FRP-1
FRP-1
FRP-1
FRP-1
FRP-1
FRP-1
FRP-1
TL-3
TL-3
TL-5
FRP-1
FRP-1
708
708
FRP-1
LOW WALL
TL-1 FRP-2
FRP-2
FRP-2
FRP-2
705
TL-1
TL-2 BASE
TL-2 BASE
TL-2 BASE
TL-2 BASE
TL-2 BASE
SERVING
119
TL-5: +/- 1,518 SF
C-1: +/- 22 SF
TL-3: +/- 1,237 SF
XX FINISH KEY RE: FINISH SCHEDULE
TILE TAKEOFF
SEALED CONCRETE
TL-1
TL-2
TL-3
TL-4
TL-5/TL-11
22 SF +/-
59 SF +/-
81 LF +/-
1,237 SF +/-280 LF +/-
46 SF +/-
262 LF +/-
TL-781 LF +/-645 SF +/-
TL-5 1,518 SF +/-
CONT. CLEARSILICONE SEALANT(TYP.)
3/4" X 3/4" X 1/16" CORNERGUARD:- RADIAL-SANDED STAINLESS STEEL FOR KITCHEN AND HALLWAY- CLEAR ANODIZED FOR DININGFROM TOP OF BASE TO CEILINGSUPPLIED & INSTALLED BY FSEC
ISOMETRIC VIEW
6"U
P T
O C
EIL
ING
VER
IFY
1' -
0"
#14 REBAR RAIL BY OWNERVENDOR
CORE DRILL &SET IN POP-ROCK
FLOOR TILE AS SPECIFIED
1/4" GAP FOR GROUT INFILL
GROUT TO CONTINUE OVER CORE
WALL FRAMING
GYP. BD. W.R. GYP. BD. FOR WET LOCATIONS
1/2" CEMENT BACKER BD. TO 12" AFF
6" CONTINUOUS COVED WALL TILE W/ 3/8" RADIUS FOR KITCHEN AND RESTROOMS
FLOOR TILE THIN SETAS SCHEDULE
CONC. SLAB
FOR WALL FIN. SEE INTERIORELEV'S & FIN. SCHEDULE
SEE SCHEDULE FOR ALL FINISHES
48" DIA.
FLOOR BEYOND
SET DRAIN TO ALLOW FOR 1/2" QUARRY TILE FLOOR FINISH
1/4"
AT
RST
RM
S.
1/2"
AT
LITC
HEN
MAXIMUM 1/2" GRATE OPENING
SLOPESLOPE
FLOOR DRAIN PERPLUMBING DRAWINGSAND SPECIFICATIONS
CONCRETE FLOOR SLABPER FOUNDATION PLAN
1"
SET FLOOR SINK TO ALLOW FOR FLOOR FINISH PER FINISH PLAN
FILL GAP BETWEEN TILE AND FLOOR SINK WITH GROUT
HALF GRATE SHOWN -SEE PLUMBING FOR
EACH ACTUAL LOCATION
FLOOR SINK WITH BEEHIVE STRAINERPER PLUMBING DRAWINGS
GRATE PER PLAN
INDIRECT WASTE PIPING WITHAIR GAP PER HEALTH DEPT.
VERIFY W/ HEALTH DEPT. INSPECTOR IF ALL FLOOR SINKS MUST FLUSHWITH THE FLOOR AS SHOWN BELOW ORTO BE SET ABOVE FINISH FLOOR
A5.10
3
3' -
0"
VER
IFY
1' -
0"
#14 REBARBY VENDOR
MITER CORNERWHERE RAILINGRETURNS 90°
CORE DRILL &SET IN POP-ROCK
LEAVE 1/2" FOR GROUT INFILL
WHERE WALLTILE OCCURS
METAL STUD
NOTE: 16 GA. ST. CORNERGUARDS 2" X 2" VERIFY HEIGHT(8'-0" TYPICAL)
STAINLESS STEEL WALL GUARD PROVIDED AND INSTALLED BY STAINLESS STEEL BY VENDOR
STAINLESS CAP TO EXTEND TO COVER TILE EDGE WHERE OCCURS
CONCRETE
SCHLUTER TRANSITION PROFILERENO-RAMP, (AE FINISH)
THIN SET TILE(RE: SCHED.)
COVE TILE BASE
FLOOR TILE -KITCHEN & RESTROOM
OUTSIDE CORNER INSIDE CORNER
WALL TILE
MITER CORNERS OF TRIM PIECE
WALL TILE
WALL TILE DETAIL AT WING WALLSFLOOR TILE AT MILLWORK BASE
GENERAL TILE INSTALLATION NOTES
1. ALWAYS USE PRE MANUFACTURED INSIDE AND OUTSIDE CORNERS AT TILE BASE. 2. WHERE TILE MEETS VINYL WALL COVERING INSTALL WALL COVERING FIRST AND EXTEND A MINIMUM OF 6" BEHIND WALL TILE. 3. START WALL TILE PATTERNS WITH A FULL TILE AT FLOOR OR ABOVE BASE UNLESS NOTED OTHERWISE.
RIPPED FLOOR TILE FOR 4" BASE
MILLWORK (BY OTHERS) TO SIT ON CONCRETE FLOOR
AB
C
E
FLOOR TILE
2X P.T. PLATE
WALL FRAMING
GYP. BD.
SEALANT TO MATCH WALLCOLOR
CONC. SLAB
CUT TILE FOROVERALL HT. PERSCHEDULE SEEELEV.ALUM. SCHLUTERCOVE
POUREDCONC.FLOORING
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A5.10
XXXXX
BID & PERMIT
XX-XX-XX
FINISH FLOORPLAN & FINISH
DETAILS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/4" = 1'-0"1
FINISH FLOOR PLAN
1. USE SQUARE EDGE BEADS AT ALL SOFFITS AND VERTICAL WALL CORNERS. (U.N.O.)2. ALL INTERIOR FINISHES SHALL COMPLY WITH 2012 IBC FOR MATERIAL ADHESIVES & PAINTING COATING VOC
LIMITS (2012 IBC). INTERIOR FINISH MATERIALS APPLIED TO WALL AND CEILINGS SHALL BE TESTED AS SPECIFIED IN 2012 IBC. ALL DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME-RETARDANT CONDITION AND MEET THE REQUIREMENTS OF LOCAL AND STATE FIRE MARSHAL CODES.
3. ALL INTERIOR FINISHES SHALL NOT EXCEED A FLAME SPREAD CLASSIFICATION OF 200.4. WALL TILE GROUT SHALL BE SEALED BY G.C.5. FLOOR TILE GROUT WILL BE GREASE, OIL, ACID AND WATER RESISTANT.6. WALLS, FLOORS, AND CEILING SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS IN IBC TABLE
803.97. GROUND & FLOOR SURFACES ALONG ACCESSIBLE ROUTES & IN ACCESSIBLE ROOMS & SPACES, INCLUDING
FLOORS, WALKS, RAMPS, STAIRS, & CURB RAMPS, SHALL BE STABLE, FIRM & SLIP-RESISTANT.8. FOR HEALTH DEPT. NOTES, SEE CS4.9. DINING SURFACES AND WORK SURFACES SHALL COMPLY WITH 902.2 AND 902.3. EXCEPTION: DINING
SURFACES AND WORK SURFACES FOR CHILDREN'S USE SHALL BE PERMITTED TO COMPLY WITH 902.4.10. DINING SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS, TABLES, LUNCH COUNTERS, AND BOOTHS.
EXAMPLES OF WORK SURFACES INCLUDE WRITING SURFACES, STUDY CARRELS, STUDENT LABORATORY STATIONS, BABY CHANGING AND OTHER TABLES OR FIXTURES FOR PERSONAL GROOMING, COUPON COUNTERS, AND WHERE COVERED BY THE ABA SCOPING PROVISIONS, EMPLOYEE WORK STATIONS.
1. EXTERIOR PAINT SHALL BE ACRYLIC SEMI-GLOSS FINISH. SEE SPECIFICATIONS FOR DETAIL.2. INTERIOR WALL PAINT SHALL BE EGG SHELL U.N.O. SEE SPECIFICATIONS FOR DETAIL.3. INTERIOR SOFFITS SHALL BE EGG SHELL FINISH U.N.O. SEE SPECIFICATIONS FOR DETAIL.4. INTERIOR CHAIR RAIL TRIM AS OCCURS AND LOW WALL CAP SHALL BE EPOXY SEMI-GLOSS FINISH IF
LAMINATE & SOLID SURFACE MATERIAL IS NOT OTHERWISE SPECIFIED. SEE SPECIFICATION FOR DETAIL.5. DOOR FRAMES AND OTHER MISCELLANEOUS METAL SHALL BE ACRYLIC SEMI-GLOSS ENAMEL U.N.O. SEE
SPECIFICATIONS FOR DETAIL.6. EXTERIOR SIDE OF EXTERIOR HOLLOW METAL DOORS AND DOOR FRAMES TO MATCH EXTERIOR BUILDING
BODY COLOR.
FINISH NOTES
PAINT FINISH NOTES
FINISH MATERIAL TAKEOFF & SYMBOL LEGEND
KEYNOTE LEGEND - NEW
700 START POINT OF FULL FLOOR TILE. FULL GROUTUNDER TRANSITIONS.
701
703 FLOOR TILE TO RUN COMPLETELY UNDER ALLSTAINLESS STEEL CABINETRY.
704 APPLY FRP TO WALLS BEHIND STAINLESS STEELEQUIPMENT.
705 STAINLESS STEEL WALL FINISH BY FSEC BEHINDFRYER. SEE K SERIES FOR MORE INFO
706 FINISH SIDE OF DIVIDER WALL AT DINING WHEREVISIBLE.
707 STAINLESS STEEL WALL FINISH BY FSEC AT MOPSINK AND TUMBLER SINK. SEE K SERIES FOR MOREINFO
708 EXPOSED FACE OF WALK IN COOLER TO REMINA -GC RESPONSIBLE TO PROTECT DURINGCONSTRUCTION. ANY DAMAGE TO WIC WILL BE THESOLE RESPONSIBILITY OF THE GC UNTIL TURNOVERTO EPL OPERATIONS
710 BR-1 SOLDIER COURSE BASE PROVIDED ANDINSTALLED BY GC.
711 TL-7 WALL TILE AS BASE WITH SCHLUTER COVEWHERE ALLOWED BY AJH - USE TL-2 AS ALTERNATEONLY WHEN REQUIRED.
1 1/2" = 1'-0"6
CORNER GUARDS
1 1/2" = 1'-0"3
QUEUE RAIL CORE
3" = 1'-0"7
COVE BASE
1 1/2" = 1'-0"4
FLOOR DRAIN
1" = 1'-0"5
FLOOR SINK 3/4" = 1'-0"
2ELEVATION - QUEUE RAIL #MTL1
REVISIONS
NO. DATE DESCRIPTION
6" = 1'-0"11
DETAIL - ST. STL. END CAP
6" = 1'-0"9
TILE TO CONCRETE TRANSITION DETAIL
3" = 1'-0"8
SCHLUTER COVE BASE
UPDATE
WHEN CA
A5.60
16
A5.60 109
3
2
A5.60 1415
12
13
A5.60
7
11
6
A5.604 5
1
8
17
101
102
105
104
103
107
108
106
AR1 A
PT-4PT-4
W-2 PT-3
AR1 B
ALIGN
W-2
EQEQ EQ
5' -
10"
5' -
10"
PT-3 101
TL-11
PT-4
WD-1
TYP. @ DINING
PT-4
MF-2
AR1 E
CENTER ART BETWEEN SODA TOWER AND STOREFRONT
5' -
10"ALIGN
PT-3
W-2
2' -
6"
W-3
TL-11TL-5
9' -
0" B
.O. B
EAM
OPEN TO ORDER AREA
OPEN TO ORDER AREA
A4.11
85
A5.62
DECORATIVE GLASS PANELS AND WALL CAP BY VENDOR. G.C. TO PROVIDE AND INSTALL LOW WALL AND BRICK VENEER.
MF-1 BK-1
W-2
PT-3
W-3
PT-4
W-3 PT-4 GYP. BD. SOFFIT BEYOND
PT-4 SS-1 SS-1FT-11 FT-11
W-2
PT-3W-2PT-3
PT-4
AR1 D
5' -
10"
PT-4
3' -
0"
ALIGN
AR1 C
EQ EQ
TL-5 TL-11
SALSA BAR WW#5
PT-4
6' -
8"2'
- 4"
OPEN TO HALLWAY
14
A5.61
MF-1
1 1/4" NAIL HEAD
T-4
FULL TILE
ADJUST STILE TO FIT FULL TILES. NO CUT TILES
W-1
SS-1W-3
109' - 0"
6
A5.10AR1 F
5' -
6"
MENU BOARD
TYP
2' - 0"
2' -
10"
OPEN TO KITCHEN
PT-4
2' - 0"
TL-5W-1
1' -
5"
TL-5 TL-11
TL-1
SS-1
WALL TILE
PT-5
DECORATIVE METAL CEILING PANEL BY VENDOR, INSTALLED BY G.C.
WD-1T-4
GL-5
MF-2
TOP & SPLASH
STILES & SIDES
SNEEZE GUARD BUTT JOINTED GLASS TO BE 1/2" TEMPERED W/ POLISHED FLAT EDGES, TYP.
PRE-PRINTED CHICKEN HEAD
MURAL VENDOR, INSTALLED BY G.C.
G.C. TO PROVIDE BACKING THIS WALL FOR FUTURE USE. SEE A7.00
A4.11
2
AR4
FRP-1
T-5
10' - 1"
OPEN TO DINING AREA
OPEN TO DINING AREA
BK-1 MF-1
5
A5.62
C6X13 STEEL CHANNEL CAP
DECORATIVE GLASS PANELS AND WALL CAP BY VENDOR. G.C. TO PROVIDE AND INSTALL LOW WALL AND BRICK VENEER. RE: 1/A5.62.
SS-1
MF-1PT-3
W-2
PT-4
MF-1
TL-5
W-2
PT-3
PT-4
ALIGN
102
TL-11
A4.11
8
A5.63
2
NOTE:CEILING BEAM & BOOTH PARTITION TO ALIGN (VERIFY IN FIELD)
AR1 B
W-3 W-3 PT-1
WOOD TRIM (BEYOND)
4X8 WOOD BEAM
GYP. BD. (BEYOND)
AR1 A
WALL BY VENDOR
110' - 3"
ALIGN
PT-3
PT-4EQ EQ
5' -
10"
W-3
EQ
PT-3
PT-4
FT-11
TYP
7' -
0"
2
A5.63
W-3PT-1 GYP. BD.
BEYOND
WALL BY VENDOR. G.C. TO INSTALL
A4.11
8 A5.60
7BOOTH PARTITION WW#2
PT-4
MF-1
PL-3MF-2
AR1 E
CENTER ART BETWEEN SODA TOWER AND STOREFRONT
5' -
10"
PT-4
ALIGN
PT-3
W-2
3' -
0"
TL-5TL-11
LASER CUT METAL PANEL BY OWNER
W-1
WD-1
W-2 WOOD CAP
1X4 AT 45° DIAGONAL W/ 1/4" REVEAL
WOOD END CAP
2X3 WOOD FRAME, WIRE BRUSHED,W/ STREET MTL. BACK FOR MAGNETIC SIGNAGE.
W-3
#12 REBAR WELDED TO FLOOR FLANGE, SATIN CLEAR COAT FINISH. (PROVIDE SAMPLE TO HDG PRIOR TO FABRICATION)
PENDANT LIGHTS @ +7'-0" A.F.F.
OVER CENTER OF TABLE. VERIFY
WITH APPROVED SEATING PLAN.
TYP.
3/8" VERT. REVEAL, TYP.
NOTE: ALL BOOTH PARTITIONS BY
MILLWORK VENDOR,
INSTALLED BY GC.
HOT DIPPED GALVANIZED FLOOR FLANGE SECURED TO RAFTER &
LOW WALL CAP, SATIN CLEAR COAT FINISH (PROVIDE SAMPLE
TO HDG PRIOR TO FABRICATION)
FT-11
FRP-1
TL-3
PT-6
BOTH SIDES
POS CABINET
108
30"x30"x12" WALL
CABINET AND SHELVES BY
G.C.
FRP-1
TL-37
A5.10
2' - 6"
3' -
2"
CLR
1' -
3"
14"x18" SHELF
POS CABINET
24" DEEP COUNTER
TL-37
A5.10
FRP-1
FRP-1
TL-3
24" DEEP COUNTER
14"X18" SHELF
30"x30"x12" WALL CABINET AND SHELVES BY G.C.
2' -
6"1'
- 3"
PT-3
10"X34" STN. STL. KICKPLATE
AR1 G
PT-4
5' -
10"
4' - 6"
TL-11
103
AR1 H
SS-1
PT-4
5' -
10"
PT-3
EQ
105
TL-11
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A5.60
XXXXX
BID & PERMIT
XX-XX-XX
ELEVATIONS &DETAILS -INTERIOR
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/4" = 1'-0"15
DINING AREA/BEV. BAR-D
1/4" = 1'-0"13
DINING AREA/BEV. BAR-B
1/4" = 1'-0"14
DINING AREA/BEV. BAR-C
1/4" = 1'-0"12
DINING AREA/BEV. BAR-A
1/4" = 1'-0"10
CUSTOMER PICK-UP AREA-D
1/4" = 1'-0"3
CUSTOMER PICK-UP AREA-B
1/4" = 1'-0"9
CUSTOMER PICK-UP AREA-C
1/4" = 1'-0"2
CUSTOMER PICK-UP AREA-A
1/4" = 1'-0"6
CENTER DINING-A
1/4" = 1'-0"11
CENTER DINING-C
1/4" = 1'-0"7
CENTER DINING-B
1/4" = 1'-0"1
OFFICE-A 1/4" = 1'-0"
4OFFICE-B
1/4" = 1'-0"5
OFFICE-C 1/4" = 1'-0"
8OFFICE-D
KEY PLAN
REVISIONS
NO. DATE DESCRIPTION
1/4" = 1'-0"16
HALLWAY-A 1/4" = 1'-0"
17HALLWAY-B
A5.61
6
A5.618A5.61
2
1
5
4
11
7
10
3
A5.6116 9
15
101
102
105
104
103
107
106
108
TL-3 TL-37
A5.10
SAFE
U/C REFRIG.
BAGS
G.C. TO PROVIDE (2) 2"W. x 16" L x 3/4" D RUNNERS @ 16" O.C.
TL-3
G.C. SHALL PROVIDE 1 1/2" DIA. GROMMETS THRU COUNTER FOR POS LINES HOLES SHALL BE FILED LOCATED. G.C. TO PROVIDE BLACK TRIM RINGS
SCREW CUP HOLDER TO COUNTER PLYWOOD SUBSTRATE
SS COUNTERTOP
MF-2
MOUNT (1) CASH DRAWERS TO COUNTER PLYWOOD SUBSTRATE
TL-1
TL-1 FRP-1
FRP-1
TL-37
A5.10
GLOVE BOX
G.C. SHALL PROVIDE 5/8" PLYWOOD BACKING AS SHOWN. INCLUDE SIDE WALL. SEE A7.00 BACKING PLAN
FRP-1
TL-3
HOODSS-1
FRP-1
TL-3
SEE WINDOW SCHEDULE FOR CORRECT DIVE-THRU WINDOW USED
A5.61
13
OPEN TO
WORK AREA
7
A5.10
FRP-2
SS CORNER GUARDS TYP. W/ FRP AT JAMBS AND HEADER
TL-3
SS-1
RFP-1
OPEN TO
WORK AREA
SUBWAY TILE PATTERN. REFER TO FINISH PLAN.
TL-3
FRP-1 FRP-1
TL-1
FRP-2
PT-67
A5.10
A5.61
14
SOFF
IT
7' -
0"
SUBWAY TILE PATTERN W/ BLACK SCORE LINES THIS WALL ONLY
103
FRP-1 FRP-1
7
A5.10
TL-3
SS-1
VERTICAL METAL COVER AT COOLER BY VENDOR
FRP-1
TL-37
A5.10
TL-3
FRP-1
7
A5.10
FIAT TERRAZZO MOP SINK 12" DEPTH CONTINUOUS MODEL TSB700. RE: MEP DRAWINGS.
SEALANT
1/2" LAYER OF MORTAR BED
STAINLESS STEEL CAPS ON ALL CURBS
SEALANT
FLASHING
FRP OR STAINLESS STEEL. RE: INTERIOR ELEVATION.
PLYWOOD BACKING
1' -
0"
COVE BASE
SEALANT
BACKER BOARD4"8' - 6"
ABOVESLAB
7' - 6"
ABOVESLAB
ROOF DECK
DRILL HOLEAT CENTER OFDOUBLE 4X6
FLANGE SCREWEDTO 4X6 WITH(4) 1/4" SCREWS
4X 6 W/HANGER
MOUNTINGESCUTCHEON
3/4" PIPECOUPLING
1 1/4"CHROMEPLATED TUBE
CEILING
1 1/4" ESCUTCHEONBY P.O.S. INSTALLER
3/4" I.P.S. PIPEBY G.C.
MONITOR ASSEMBLYBY P.O.S. INSTALLER
NOTE: BRACING BY VENDOR VERIFY LOCATIONS WITH P.O.S. EQUIPMENT INSTALLER
SUPPORT POST BY POS INSTALLER
+ 7' - 0"
MAGNETIC MENUSIGNAGE BY OTHERS
+ 9' - 2"
LAY-IN CEILING, RE: RCP
METAL CABINET MENU BOARD TO BE PROVDED AND INSTALLED BY OWNER'S VENDOR
+ 9' - 0"
HOOD RE: MECHANICAL
SOFFIT OVER ORDER COUNTER
THREADED ROD TO FRAME
TL-37
A5.10
FRP-1SS-1SS-1
SS-1
TL-3
12
A5.61
FRP-1
ON (3) SIDES
CHEM RACK ABOVE MOP SINK. SUPPLIED BY OWNER AND INSTALLED BY G.C.
SS-1
PT-6TL-3
FRP-1
FRP-1
7
A5.10
108
FRP-1
TL-3
EXIT SIGNCLG MTD
AIR CURTAIN TO BE DOOR ACTIVATED
7
A5.10
107
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A5.61
XXXXX
BID & PERMIT
XX-XX-XX
ELEVATIONS &DETAILS -INTERIOR
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
INTERIOR NOTES
1. REGARDING NEW CEILING/ WALL-HUNG EQUIPMENT/ SECURITY & TV MONITORS, BUILT-IN MILLWORK/ CASEWORK COUNTERTOP EXTENSIONS, EXTERIOR AND/ OR INTERIOR WALL-MOUNTED SCONE LIGHT FIXTURES, DRINKING FOUNTAINS NOT SET BACK WITHIN AN ALCOVE (MAY NEED A VERTICAL CANE-DETECTION "SKIRT" ON THE REGULAR-HEIGHT FIXTURE), ECT. THAT MAY BE HAZARDS ALONG ACCESSIBLE ROUTES (AS MAY BE APPLICABLE).
2. VERTICAL CLEARANCE SHALL BE 80 INCHES HIGH MINIMUM. GUARDRAILS OR OTHER BARRIERS SHALL BE PROVIDED WHERE THE VERTICAL CLEARANCE IS LESS THAN 80 INCHES HIGH. THE LEADING EDGE OF SUCH GUARDRAIL OR BARRIER SHALL BE LOCATED 27 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
EXCEPTION: DOOR CLOSERS AND DOOR STOPS SHALL BE PERMITTED TO BE 78 INCHES MINIMUM ABOVE THE FINISH FLOOR OR GROUND.
3. OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES AND NOT MORE THAN 80 INCHES ABOVE THE FINISH FLOOR OR GROUND SHALL PROTRUDE 4 INCHES MAXIMUM HORIZONTALLY INTO THE CIRCULATION PATH.
EXCEPTION: HANDRAILS SHALL BE PERMITTED TO PROTRUDE 4 1/2 INCHES MAXIMUM.
ADVISORY 307.2 PROTRUSION LIMITS. WHEN A CANE IS USED AND THE ELEMENT IS IN THE DETECTABLE RANGE, IT GIVES A PERSON SUFFICIENT TIME TO DETECT THE ELEMENT WITH THE CANE BEFORE THERE IS BODY CONTACT. ELEMENTS LOCATED ON CIRCULATION PATHS, INCLUDING OPERABLE ELEMENTS, MUST COMPLY WITH REQUIREMENTS FOR PROTRUDING OBJECTS. FOR EXAMPLE, AWNINGS AND THEIR SUPPORTING STRUCTURES CANNOT REDUCE THE MINIMUM REQUIRED VERTICAL CLEARANCE. SIMILARLY, CASEMENT WINDOWS, WHEN OPEN, CANNOT ENCROACH MORE THAN 4 INCHES INTO CIRCULATION PATHS ABOVE 27 INCHES.
4. INTRUDING OBJECTS SHALL NOT REDUCE THE CLEAR WIDTH REQUIRED FOR ACCESSIBLE ROUTES. PROTRUDING OBJECTS ON CIRCULATION PATHS SHALL COMPLY WITH 307.
EXCEPTIONS:
5. WITHIN AREAS OF SPORT ACTIVITY, PROTRUDING OBJECTS ON CIRCULATION PATHS SHALL NOT BE REQUIRED TO COMPLY WITH 307 PROVIDED THAT GROUND LEVEL ACCESSIBLE ROUTES PROVIDE VERTICAL CLEARANCE IN COMPLIANCE WITH 1008.2.
6. PLEASE VERIFY COMPLIANCE ACCORDINGLY PRIOR TO THE REQUIRED ON-SITE ACCESSIBILITY/ USABILITY INSPECTION.
7. PARTS ON ACCESSIBLE ELEMENTS, ACCESSIBLE ROUTES, AND IN ACCESSIBLE ROOMS AND SPACES SHALL COMPLY WITH 309. CONTROLS COVERED BY 205.1 INCLUDE, BUT ARE NOT LIMITED TO, LIGHT SWITCHES, CIRCUIT BREAKERS, DUPLEXES AND OTHER CONVENIENCE RECEPTACLES, ENVIRONMENTAL AND APPLIANCE CONTROLS, PLUMBING FIXTURE CONTROLS, AND SECURITY AND INTERCOM SYSTEMS.
EXCEPTIONS:
A. OPERABLE PARTS THAT ARE INTENDED FOR USE ONLY BY SERVICE OR MAINTENANCE PERSONNEL SHALL NOT BE REQUIRED TO COMPLY WITH 309.B. ELECTRICAL OR COMMUNICATION RECEPTACLES SERVING A DEDICATED USE SHALL NOT BE REQUIRED TO COMPLY WITH 309.C. WHERE 2 OR MORE OUTLETS ARE PROVIDED IN A KITCHEN ABOVE A LENGTH OF COUNTER TOP THAT IS UNINTERRUPTED BY A SINK OR APPLIANCE, ONE OUTLET SHALL NOT BE REQUIRED TO COMPLY WITH 309.D. FLOOR ELECTRICAL RECEPTACLES SHALL NOT BE REQUIRED TO COMPLY WITH 309.E. HVAC DIFFUSERS SHALL NOT BE REQUIRED TO COMPLY WITH 309.F. EXCEPT FOR LIGHT SWITCHES, WHERE REDUNDANT CONTROLS ARE PROVIDED FOR A SINGLE ELEMENT, ONE CONTROL IN EACH SPACE SHALL NOT BE REQUIRED TO COMPLY WITH 309.G. CLEATS AND OTHER BOAT SECUREMENT DEVICES SHALL NOT BE REQUIRED TO COMPLY WITH 309.3.H. EXERCISE MACHINES AND EXERCISE EQUIPMENT SHALL NOT BE REQUIRED TO COMPLY WITH 309.
1/4" = 1'-0"2
WALK-IN COOLER-B 1/4" = 1'-0"
1WALK-IN COOLER-A
1/4" = 1'-0"11
KITCHEN-D
1/4" = 1'-0"7
KITCHEN-B
1/4" = 1'-0"10
KITCHEN-C 1/4" = 1'-0"
6KITCHEN-A
1/4" = 1'-0"8
WORK AREA-C
1/4" = 1'-0"5
WORK AREA-B 1/4" = 1'-0"
4WORK AREA-A
KEY PLAN
1 1/2" = 1'-0"12
MOP SINK
3/4" = 1'-0"13
MONITOR MOUNTING
REVISIONS
NO. DATE DESCRIPTION
3" = 1'-0"14
MENU BOARD
1/4" = 1'-0"3
WALK-IN COOLER-C
1/4" = 1'-0"16
WORK AREA-F
1/4" = 1'-0"15
WORK AREA-E
1/4" = 1'-0"9
WORK AREA-D
3' - 11 1/2" 2" 7' - 10" 2" 3' - 11 1/2"
1" EQ. 1" EQ. 1" EQ. 1" 1" EQ. 1" EQ. 1" EQ. 1" EQ. 1" EQ. 1" EQ. 1" 1" EQ. 1" EQ. 1" EQ. 1"
ROOM DIVIDER WALL BY
VENDOR. GC TO INSTALL LOW
WALL FRAMING, BRICK CENEER,
CAULK AND SEAL
GLASS FINISH LEGEND
9' -
0"BY
G.C
.
3' -
9"
BY V
END
OR
5' -
3"
OPEN
OPEN OPEN
A5.62
4
A5.62
3
3
A5.62
4
A5.62
5
A5.62
GL-1 GL-2 GL-3 GL-4 GL-6
GROUT 1/4" GAPS AFTER VENDOR INSTALL
17' - 1" G.C.LOW WALL
A5.62
9
7
A5.62
8
A5.62
A5.62
9
16' - 5"
17' - 9"
NOTE: GC IS RESPONSIBLE FOR COORDINATING ALL DIMENSIONS AND CLEARANCES REQUIRED WITH OWNER VENDOR TO ENSURE SMOOTH INSTALLATION.
1/2 X 1/2 X 3/32 STEEL ANGLE GLASS STOP - TYP.
1 X 2 X .060STEEL TUBEMULLION - TYP.
FOR GLASSTYP. SEE
2 X 4 X .090 STEEL TUBE JAMB - TYP.
C6 X 13 STEEL CHANNEL SILL -TYP.
THINSET BRICK VENEER
A5.61
1GL-
MF1
MF1
MF1
MF1
BK1
SEALANT BY GCSEALANT
1/2 X 1/2 X 3/32 STEEL ANGLE GLASS STOP -TYP.
1 X 2 X .060 STEEL TUBE MULLION - TYP.
FOR GLASSTYP. SEE
2 X 4 X .090 STEEL TUBE JAMB - TYP.
A5.61
1
MF1
MF1
MF1
GL-
1/2 X 1/2 X 3/32 STEEL ANGLE GLASS STOP - TYP.
1 X 2 X .060 STEEL TUBE MULLION - TYP.
FOR GLASSTYP. SEE
GL-
MF1
MF1
A5.61
1
5' -
3"
1' -
1 1/
2"2
1/2"
1' -
1 1/
2"2
1/2"
9' -
0"
A5.62
6
A5.62
4
A5.62
2
2x3 RIPPED STUDS AT16" O.C. W/ 3/4"WONDER BOARD EA. SIDE
GC TO SUPPLY AND INSTALLTHINSET BRICKVENEER BOTH SIDES
9' - 0" A.F.F.
GC TO SUPPLY AND INSTALL THINSET BRICKSOLDIERS COURSE VENEER BOTH SIDES. SET ON TOP OF TILE FLOOR FINISH
BK-1
BK-1
7 1/
2"
FINISHED
5"
3' -
8 1/
4" T
O S
TUD
1/2"
FRO
M T
OP
STO
P BR
ICK
GC
OWNER/ VENDOR
FLOOR TILE FINISH PER SCHEDULE
CONCRETE SLAB
1/2 X 1/2 X 3/32 STEEL ANGLE GLASS STOP - TYP.
1 X 2 X .060 STEEL TUBE MULLION - TYP.
FOR GLASS TYP. SEE
2 X 4 X .090 STEEL TUBE JAMB - TYP.
MF1
MF1
MF1
GLA5.61
1
SEALANTSEALANT
GC
OWNER/ VENDOR
1/2 X 1/2 X 3/32 STEEL ANGLE GLASSSTOP - TYP.
1 X 2 X .060 STEEL TUBE MULLION -TYP.
FOR GLASS TYP. SEE
2 X 4 X .090 STEEL TUBE JAMB - TYP.
VERTICAL STEEL TUBE POST SUPPLIED AND INSTALLED BY OWNER VENDOR
A5.61
1
MF1
MF1
MF1
GL-
MF-1
THINSET BRICK VENEEREACH SIDE OF WALL
VERTICAL STEEL TUBE POST SUPPLIED AND INSTALLED BY OWNER VENDOR
MF-1
SOLDIER COURSE AT BOTTOM
VERTICAL STEEL TUBE POST SUPPLIED AND INSTALLED BY OWNER VENDOR
LINE OF STEELCHANNEL ABOVE
THINSET BRICK VENEEREACH SIDE OF WALL
3/4" WONDERBOARDEACH SIDE OF WALL
MF-1106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
TKa r c h i t e c t s
I
®™N T E R N A T I O N A L
____________________________
PROJECT #
SHEET NUMBER
A5.62
XXXXX
BID & PERMIT
XX-XX-XX
ELEVATIONS &DETAILS -INTERIOR
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
3/4" = 1'-0"1
PLAN & ELEVATION - ROOM DIVIDERWALL, WW#4
6" = 1'-0"2
DETAIL - STL. CHANNEL CAP
6" = 1'-0"3
DETAIL - STL. WINDOW FRAME MULLION 6" = 1'-0"
4DETAIL - STL. WINDOW FRAME
1 1/2" = 1'-0"5
SECTION - ROOM DIVIDER WINDOWWALL
6" = 1'-0"6
DETAIL - STL. WINDOW FRAME HEAD 3" = 1'-0"
7
DETAIL - STL. WDW. FRAME AT WD.COL.
3" = 1'-0"9
DETAIL - WD. COL. BASE/HEAD
3" = 1'-0"8
DETAIL - LOW WALL AT WD. COL.
REVISIONS
NO. DATE DESCRIPTION
3' -
6"
9' -
8"
3' -
7 1/
2"
1/2" TYP.
DIAGONAL 1X4 AT 45° W/ 1/4" GAP BETWEEN BOARDS BOTH SIDES OF PARTITION
PLYWOOD SUBSTRATE,PAINT BLACK
THREADED ROD, WELDED TO REBAR. CUT ROD TO PROPER LENGTH TO FIT CAP NUT.
WOOD FACE FRAME
14GA. STEEL PATTERN
#12 REBAR WELDED TO FLOOR FLANGE, SATIN CLEAR COAT FINISH. (PROVIDE SAMPLE TO HDG PRIOR TO FABRICATION)
HOT DIPPED GALVANIZED FLOOR FLANGE SECURED TO RAFTER & LOW WALL CAP, SATIN CLEAR COAT FINISH (PROVIDE SAMPLE TO HDG PRIOR TO FABRICATION)
2X SOLID STOCK WOOD CAP W/ EASED EDGES
+ 2' - 6"T.O. TABLEA.F.F. TYP.
2"
109'-8"
110'-6"
10"
109'-10"
LIGHT FIXTURES RE: ELECTRICAL
2' - 0 1/2" 2' - 7" 3' - 2" 2' - 7" 2' - 0 1/2"
12' - 5"
6"
DASHED LINE OF LOWWALL BELOW CAP
LARGE DASHED LINE OF METAL FAME FORSIGNAGE ABOVE
FLOOR FLANGE SECURED TORAFTER & LOW WALL CAP,
27x42 24x27
24x30
A5.60
7
2' - 6"
2' - 6"T.O. TABLEA.F.F. TYP.
27x42
2' - 6"
24x30
2' - 6"
T.O. TABLEA.F.F. TYP.
MF-1
ALL WORK TO BE BY OWNER'S MILLWORK VENDOR. GC TO INSTALL TILE BASE AT LOW WALL AFTER VENDOR COMPLETES INSTALL.
WALL PROVIDED BY MILLWORK VENDOR.
BOOTH-TYPE DINING ON THE SIDE AND IN THE CENTER OF THE NEW RESTAURANT - ALL AT HIGH 30" ABOVE FINISHED FLOOR (AFF.) TABLES AND 18" CHAIRS. IF THE NOTED SEATING IS FIXED, VERIFY THAT AT LEAST A 5% PORTION OF THE FIXED DINING TABLE SURFACES IN THE MULTIPLE DINING OPPORTUNITY AREAS FULLY COMPLY REGARDING THE TABLE MOUNTED AT A MAXIMUM 34" AFF. - DO NOT DENY ACCESS BY PEOPLE WITH DISABILITIES (I.E. - ARE NOT MOUNTED TOO HIGH AND ALLOW THE MINIMUM FRONT APPROACH ARM-RESTS/ KNEE/ TOE SPACE CLEARANCES REQUIRED. PLEASE VERIFY COMPLIANCE ACCORDINGLY PRIOR TO THE REQUIRED ON-SITE ACCESSIBILITY/ USABILITY INSPECTION.
DINING SURFACES AND WORK SURFACES SHALL COMPLY WITH 902.2 AND 902.3. EXCEPTION: DINING SURFACES AND WORK SURFACES FOR CHILDREN'S USE SHALL BE PERMITTED TO COMPLY WITH 902.4.
DINING SURFACES INCLUDE, BUT ARE NOT LIMITED TO, BARS, TABLES, LUNCH COUNTERS, AND BOOTHS. EXAMPLES OF WORK SURFACES INCLUDE WRITING SURFACES, STUDY CARRELS, STUDENT LABORATORY STATIONS, BABY CHANGING AND OTHER TABLES OR FIXTURES FOR PERSONAL GROOMING, COUPON COUNTERS, AND WHERE COVERED BY THE ABA SCOPING PROVISIONS, EMPLOYEE WORK STATIONS.
A CLEAR FLOOR SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED.
THE TOPS OF DINING SURFACES AND WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES MAXIMUM AFF.
FURNITURE NOTE
2"X P.T. SILL PLATE
ANCHOR BOLT PER STRUCT.DWG.
WATER RESISTANT GYP. BOARD
WALL PER PLAN
FINISH PER INTERIORELEVATIONS
5/8" DUROCK TO 12" ABOVE SLAB
CONT. "J" MOLD TRIM TO MATCH FINISH (FRP @ FRP, STAINLESS @ STAINLESS)
6" HIGH COVE BASE W/ 3/8" R
FLOOR TILE PER PLAN
1/2"
1 1/
2"
WALL PER PLANS
CONT. BEAD OF CLEAR SILICONE SEAL AFTER INSTALLATION OF WALL PANELS AND BASE
CONCRETE SLAB
1' -
0"
GYP. BOARD PAINTED
1/2" 1/4"
3/4"
1/4"
2 1/
4"
2 1/
2"
1X3 SOLID STOCK CHAIR RAIL PROVIDED AND INSTALLED BY OWNER VENDOR
GYP. BOARD PAINTED
PT4
W3
PT3
2' - 6"
SIMPSON DTC ROOF TRUSS CLIP ON BOTH SIDES
6" M
IN.
5/8"
GYP
. BD
. U.O
.N.
4' -
0"
5/8"
PLY
WO
OD
4' -
0"
5/8"
GYP
. BD
.
2' -
6"
VAR
IES
( SEE
INT.
ELE
VATI
ON
S )
1' -
6"
A5.63
5
SEE INTERIOR. ELEV.FOR FINISHES
UTILITY AND/ORDISPLAY SHELVINGSEE KITCHEN DWG'SFOR TYPE, QTY. &LOCATIONS.
SEE INT. ELEV. SHEETSFOR BASE TYPES
ROOF TRUSSES, TYP.
CLR
.1"
METAL STUD WALLS AT INTERIOR, TYP.
INTERIOR VIEW
SEE WINDOW SCHEDULE FOR PROPER DRIVE THRU WINDOW. VERIFY TYPE PRIOR TO ORDERING AND INSTALLING.
4' - 0"
OPENING
18" MAX. FOR
PLAN VIEW
EXTERIOR
INTERIOR TYPE"E"
CENTER J-BOXON ACTIVE LEAF
1/2" PLYWOOD
2X6 STUD
STUCCOEXT. FIN.
5/8" GYP. BD.
SEE WINDOW SCHEDULE FORAIR CURTAIN LOCATION/INFO.
NOTE: ACTIVE LEAF SHALL BE ON THE KITCHENSIDE OF THE BUILDING (SIDE AWAY FROM THEDINING ROOM). G.C. TO CONFIRM DIRECTIONWITH SUB-CONTRACTOR PRIOR TO ORDERING
3' - 7 3/4"
RO
UG
H O
PEN
ING
1' -
0"
1 1/
2" S
HEL
F
NO
MIN
AL
5' -
0"
3' - 8"
36" T
O F
INIS
H O
FIN
TER
IOR
FLO
OR
SEE WINDOW SCHEDULE FOR AIR CURTAINLOCATION & INFO.
EQ EQ
SEALANTSEALANT
5/8" TYP "X"GYP. BD.
PAINT PERFIN, SCHED.
PLYWD.(SEE STRUCT.)
METAL CORNERBEAD TYP.
5/8" TYPE "X"GYP. BD.
DRIVE-IN PASSTHRU METALWINDOW HEAD
CLEAR GLASS(SEE SCHED.)
6"X WOOD HEADER(SEE STRUCT.)
SHIM AS REQUIRED
TILE OVER PLYWOOD
FINISH STOP ANDFLASHING
CAULKINGAND BACKER ROD
Z-METAL FLASHINGAT HEAD
4"
1"
1/2"
1/4"
SEALANT
INTERIOR
2 1/
2"
SS SHELF DRIVE-IN PASSTHRU WINDOW
EXTERIOR
TILE OVER PLYWOOD
BATTINSULATION
5/8" CDXW/ FRP FINISH
2-2X DBL.PLATE(SEE STRUCT.)
2X STUD WALL(SEE STRUCT.)
36"
A.F.F.
INTERIOREXTERIOR
SS SHELF
1 1/
2"34
1/2
"
A.F.
F.
READY ACCESS
C.R. LAURENCE
SEALANT AND BACKER ROD
SEALANT AND BACKER ROD
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
TKa r c h i t e c t s
I
®™N T E R N A T I O N A L
____________________________
PROJECT #
SHEET NUMBER
A5.63
XXXXX
BID & PERMIT
XX-XX-XX
ELEVATIONS &DETAILS -INTERIOR
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
3/4" = 1'-0"2
SECTION - BOOTHWORK PARTITION
1/2" = 1'-0"1
PLAN - BOOTH PARTITION #WW2
REVISIONS
NO. DATE DESCRIPTION
1 1/2" = 1'-0"5
WATERPROOF WALL BASE @ INT.
6" = 1'-0"3
CHAIR RAIL
3/4" = 1'-0"4
WALL SECTION 3/4" = 1'-0"
7DRIVE THRU WINDOW
3" = 1'-0"6
DRIVE-THRU WINDOW HEAD
1 1/2" = 1'-0"8
DRIVE-THRU WINDOW SILL
ARTWORK
MARK
A
B
C
D
E
DINING
LOCATION IMAGE SIZE OVERALL SIZE
30"X48" 34"X52"
AR4 SALSA BAR
DINING
DINING
DINING
ORDER COUNTER
42"X56"
BY VENDOR
TYPE
AR1
AR1
AR1
AR1
AR1
AR4
IMAGE COMMENTS
BY VENDOR
FIELD VERIFY. IMAGE TO BE PRINTED DIRECT TO COMMERCIAL GRADE VINYL WALL COVERING THEN APPLIED TO WALL.
BY VENDOR
BY VENDOR
BY VENDOR
BY VENDOR
BY VENDOR
46"X60"
30"X48" 34"X52"
30"X48" 34"X52"
9'-11"X8'-6"
F
G
H
AR1
AR1
AR1
DINING
CORRIDOR
CORRIDOR
30"X48" 34"X52"
30"X48" 34"X52"
30"X48" 34"X52"
BY VENDOR
BY VENDOR
BY VENDOR30"X48" 34"X52"
AR2 EXTERIOR MARQUEE BY VENDOR
ALL ARTWORK SIZES, LOCATION & MOUNTING HEIGHT TO BE APPROVED BY EPL OPERATIONS.
ALL ARTWORK SIZES, LOCATION & MOUNTING HEIGHT TO BE APPROVED BY EPL OPERATIONS.
ALL ARTWORK SIZES, LOCATION & MOUNTING HEIGHT TO BE APPROVED BY EPL OPERATIONS.
ALL ARTWORK SIZES, LOCATION & MOUNTING HEIGHT TO BE APPROVED BY EPL OPERATIONS.
ALL ARTWORK SIZES, LOCATION & MOUNTING HEIGHT TO BE APPROVED BY EPL OPERATIONS.
ALL ARTWORK SIZES, LOCATION & MOUNTING HEIGHT TO BE APPROVED BY EPL OPERATIONS.
ALL ARTWORK SIZES, LOCATION & MOUNTING HEIGHT TO BE APPROVED BY EPL OPERATIONS.
ALL ARTWORK SIZES, LOCATION & MOUNTING HEIGHT TO BE APPROVED BY EPL OPERATIONS.
ALL ARTWORK SIZES, LOCATION & MOUNTING HEIGHT TO BE APPROVED BY EPL OPERATIONS.AR2 72"X48"70 1/2"X46 1/2"
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A6.00
XXXXX
BID & PERMIT
XX-XX-XX
FINISHSCHEDULES
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
INTERIOR FINISH MATERIALS LISTFINISH TYPE OF MATERIAL MANUFACTURER NAME / MODEL NO. COLOR SIZE LOCATION / NOTES
PLASTIC LAMINATE
PL-1 PLASTIC LAMINATE WILSONART ARBORITE - LAMINATE W460 WINTER ELM 48" X 96" PANELS. CUT TO SIZE TABLE TOPS, PROVIDED BY FURNITURE VENDOR
PL-4 PLASTIC LAMINATE OCTOPUS PRODUCTS CONTACT:LOUIE ESQUEDA (818) 522-2048
OCTOPUS PRODUCTS - OCTOLAM 964 HAZEL CAMBRIC RESTROOM PARTITIONS
PL-5 PLASTIC LAMINATE WILSONART WILSONART - #1573 FROSTY WHITE DOOR FINISH ON KITCHEN SIDE AND ALT. TO PT-6
WALL COVERING
BK-1 CLAY BRICK MCNEAR BRICK & BLOCK CONTACT:RESOURCE BUILDING MATERIALS(949) 855-9994
MCNEAR BRICK & BLOCK - THIN BRICK -SANDMOLD SERIES
TIVOLI 8 1/8" X 2 7/16" X 5/8" W/ CORNER PIECES ASREQ'D
SALSA BAR BACK WALL & LOW WALL AT DININING MORTAR COLOR: SPEC MIX TYPE #213 -SLATE JOINT WIDTH 3/8"
FRP-1 FIBERGLASS REINFORCEDPLASTIC
MARLITE CONTACT: CUSTOMERSERVICE (800) 377-1221
MARLITE - FIBERGLASS REINFORCEDPLASTIC PANEL W/ NONPOROUS SURFACE
P - 100 WHITE BACKSIDE OF FRONT COUNTER LOW WALL, REAR OF KITCHEN, & WATER HEATER CLOSET;HEAVY-DUTY 1" CORNER GUARDS THROUGHOUT
FRP-2 FIBERGLASS REINFORCEDPLASTIC
MARLITE CONTACT: CUSTOMERSERVICE (800) 377-1221
MARLITE - SYMMETRIX A916G63FIBERGLASS REINFORCED PLASTIC PANEL
P - 100 WHITE W/ BLACK CORE WALL VISIBLE FROM ORDER COUNTER
PAINT
PT-1 PAINT PPG PAINTS #A2009 BLACK MICA #30BB 05/022 SEE"NOTES" FOR SHEEN
CAD CEILING PANELS (CT-3) & HIGH CEILING AT CENTER OF DINING AREA - FLATT FINISH.U.N.O LRV=6
PT-2 PAINT PPG PAINTS #A2008 GREY TABBY #00NN 16/000 CEILING LRV = 14
PT-3 PAINT PPG PAINTS PPG 1001-5 DOVER GRAY WALLS, CEILING & WAINSCOT AS NOTED LRV = 23; RESTROOM DOORS (VESTIBULE SIDE) -SEMI-GLOSS LRV = 6
PT-4 PAINT PPG PAINTS PPG 1007-4 HOT STONE SEE "NOTES" FOR SHEEN TECTUM CEILING PANELS (CT1) & MAIN DINNING ROOM WALLS - EGGSHELL FINISH RESTROOMCEILING, FRONT COUNTER SOFFIT & RESTROOM DOORS (RESTROOM SIDE) - SEMI-GLOSS
PT-5 PAINT PPG PAINTS PPG 1008-2 SOTRM'S COMING HIGH CEILING ABOVE CAD PANELS. SEMI-GLOSS FINISH. U.N.O
PT-6 PAINT PPG PAINTS PPG 1007-1 WILLOW SPRINGS KITCHEN, DOOR FRAMES & DOORS (KITCHEN, OFFICE, INT. SIDE OF REAR SERVICE DOOR).SEMI-GLOSS FINISH. U.N.O.
METAL FINISHES
MF-1 POWDER COAT METAL BY VENDOR COUCH & PHILIPPI MATTE BLACK THROUGHOUT, SEE DRAWING
MF-2 STAINLESS STEEL STAINLESS STEEL VENDOR ORBITAL SANDED COUNTERTOPS
SS-1 STAINLEES STEEL WALL PANEL KITCHEN VENDOR STAINLESS STEEL VENDOR WALLS AT BROILER
TILE
TL-1 WALL TILE TILEPORT WHITE GLOSSY 3" X 6" SIDE WALLS AT FRONT COUNTER GROUT: MAPEI - 47 CHARCOAL; JOINT WIDTH: 1/8" LEAD TIME: 1-2 WEEKS
TL-2 COVE BASE (WALL TILE) TILEPORT - CROSSVILLE THIN FOOT WHITE GLOSSY 4" X 8" X 1/4" RESTROOMS INTERIOR COVE BASE TILE (K175) GROUT: MAPEI - 01 ALABASTER; JOINT WIDTH:1/16"
TL-3 FLOOR TILE TILEPORT QUARRY TILE RED SMOOTH 6" X 6" X 3/8"
TL-3 COVE BASE TILEPORT QUARRY TILE RED
TL-3 TRIM (LEFT OUTSIDE) TILEPORT QUARRY TILE RED
TL-3 TRIM (RIGHT OUTSIDE) TILEPORT QUARRY TILE RED
TL-3 TRIM (INSIDE) TILEPORT QUARRY TILE RED
TL-4 FLOOR TILE TILEPORT QUARRY TILE RED ABRASIVE 6" X 6" X 3/8" KITCHEN FLOOR, SCHLUTER AT KITCHEN & AT TUMBLER, SMOOTH UNDER EQUIPMENT,ABRASIVE AT WALKWAYS. GROUT: MAPEI - 47 CHARCOAL; JOINT WIDTH: 3/8" LEAD TIME: 3-4WEEKS
TL-7 WALL TILE TILEPORT WHITE GLOSSY 4"X 12" RESTROOM WALLS (FULL HEIGHT OF WALL) USE W/ SCHLUTER DILEX-AHKA (ANODIZEDALUMINUM) COVER AT FLOOR WHERE REQ'D BY HEALTH DEPT, USE COVE BASE TO MATCHWALL TILE TRIM GROUT: MAPEI - 01 ALABASTER; JOINT WIDTH 1/16"
TL-9 CONCRETE TILE TILEPORT ECOCRETE WEATHERED BLACK 24" X 24" X 5/16" DINING ROOM FLOOR, CORRIDOR FLOOR, RESTROOM FLOOR
TL-10 CONCRETE TILE TILEPORT ECOCRETE WEATHERED BLACK 6" X 12" DINING ROOM FLOOR, CORRIDOR FLOOR, RESTROOM FLOOR
TL-11 /TL-5
CONCRETE TILE TILEPORT ECOCRETE - CUT BASE WEATHERED BLACK 6" X 12" (CUT FROM 24" X 24") DINING ROOM FLOOR, CORRIDOR FLOOR, RESTROOM FLOOR
CEILINGS
CL-1 ACOUSTICAL CEILING PANELS TECTUM, INC. CONTACT: CUST.SERVICE (714) 892-2882
ARMSTRONG CORTEGA INTERIORACOUSTICAL PANELS - LAY-IN SUSPENDED
PAINT PT-4 (SEE SPEC AT LEFT) 24" WIDE X 48" LENGTH DINING ROOM CEILING STAGGERED PATTERN, SEE RCP, 24"X24" AT ORDERING ANDRESTROOMS
CL-1 GRID SYSTEM ARMSTRONG 15/16 GRID STAC PAINT TO MATCH CEILING TILE (PT-4) 15/16" TO BE USED WITH ACOUSTICAL LAY-IN AT DINING AREA FOR STAGGERED PATTERN
CL-2 CEILING GRID & TILES USG CONTACT: CUST. SERVICE (888)874-2450
GRID: DONN DX/DXL TILE: SHEETROCKBRAND CLIMAPLUS FIRECODE LAY-INVINYL PANELS ITEM# 3200
GRID & TILE: FLAT WHITE 050 24" X 48" TILES KITCHEN CEILING CLEAN ROOM PANELS (VINYL-LAMINATED FACE W/ SEALED BACK & EDGES)CLASS 'A' VINYL FLAME SPREAD: 25; SMOKE DEVELOPED; 50
CL-3 CAD CAM PANELS CLASS 'A' 1/2" MDF W/ CAD CAM PATTERN PANELS: PAINT P1 WOOD TRIM T-BAR:W3
CUSTOMER PICK-UP AREA
CL-4 GYP. BOARD SEE CEILING PLAN FOR PAINT.SMOOTH FINISH.
5/8" THICK SERVING & WATER HEATER
WOOD
W-1 STAIN GRADE WOOD SPECIES: BIRCH STAIN TO MATCH HATCH DESIGNGROUP'S CONTROL SAMPLE -4861K-07"GOLD ALCHEMY"
VARIES, SEE DRAWINGS LOW WALLS & WOOD FIXTURES PLYWOOD, VENEER & SOLID STOCK
W-2 STAIN GRADE WOOD SPECIES: DOUGLAS FIR MATTE STAIN TO MATCH HDG'SCONTROL SAMPLE - 9283-NG "WALNUTRIFTWOOD"
VARIES, SEE DRAWINGS LOW WALL CAP, CEILING TRIM, CHAIR RAIL, BOOTH BASE & MENU BOARD FRAME PLAIN SAWNWITH LIGHT SANDBLASTING
W-3 STAIN GRADE WOOD SPECIES: DOUGLAS FIR STAIN TO MATCH HDG'S CONTROLSAMPLE - 9283-NG "WALNUTRIFTWOOD"
VARIES, SEE DRAWINGS CEILING BEAMS & TRIM PLYWOOD, VENEER & SOLID STOCK
RUBBER BASE
RB-1 COVE BASE BURKE RUBBER / COVE BLACK 4" MIN WATER HEATER / ELEC. ROOM 3/8" COVE BASE
CONCRETE SEALANT
C-1 SEALED CONCRETE SEAL-KRETE CLEAR-SEAL 365001 LOW GLOSS SEALER EXTERIOR GRADE CONCRETE SEALANT NEEDED AT WATER HEATER CLOSET (114) & TRASHENCLOSURE PAD
INTERIOR FINISH SCHEDULEROOM NUM. NUMBER FLOOR FINISH BASE FINISH WALL FINISH
CEILINGFINISH COMMENTS
FIRST FLOOR
DINING 100 TL-9 TL-11 P-3 BELOW WAINSCOT, P-4ABOVE WAINSCOT
CL-1/ CL-4 /PT-4
GYP. BD CEILING TO BE SMOOTH COAT. SEE ELEV.FOR PATTERN
SALSA BAR 100a TL-9 TL-5 AR4 CL-4/ SOFFITPT-4
CHICKEN HEAD MURAL BY VENDOR. INSTALLED BYG.C./ SEE CEILING PLAN FOR ADDITIONALINFORMATION
CUSTOMERPICK-UP
101 TL-9 TL-5 TL-1/ FRP SEE ELEV. CL-3/ CL-1/SOFFIT PT-4
SOFFIT AND GYP BD CEILING TO BE SMOOTH
KITCHEN 103 TL-3 TL-3 COVE TL-1/ FRP SEE ELEV. CL-2
OFFICE 105 TL-3 TL-3 COVE FRP-1 CL-2
STORAGE 106 TL-3 TL-3 COVE FRP-1 CL-2
COOLER 107 TL-3 TL-3 COVE - PER MANUFACTURE'S REQ
DRIVE-THRU 109 TL-3 TL-3 COVE TL-1/ FRP SEE ELEV. CL-2
WOMENS 110 TL-9 TL-7 T-7 (SEE ELEV.) OVER WATERRESISTIVE GYP. BD., GROUTSIZE 1/16"
CL-2
MENS 111 TL-9 TL-7 T-7 (SEE ELEV.) OVER WATERRESISTIVE GYP. BD., GROUTSIZE 1/16"
CL-2
VESTIBULE 113 TL-9 TL-11 PT-4 CL-4/ PT-3
WATER HEATER 114 C-1 RB-1 CL-4/PT-6
WORK AREA 118 TL-3 TL-3 COVE T-1/ FRP SEE ELEV. CL-2
SERVING 119 TL-3 TL-3 COVE TL-1 SEE ELEV. CL-2
REAR KITCHENDELIVERY
122
REVISIONS
NO. DATE DESCRIPTION
PANIC HARDWARE
INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN
44" M
AX
30" M
IN
DOORS SHALL BEDARK BRONZE
8' -
0"
10"
10"
ROTON HINGE
T= TEMPERED GLASS
T T
8' -
0"
DOORS SHALL BEDARK BRONZE
INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN
ROTON HINGE
PANIC HARDWARE 5' -
0"
EQ. EQ.
3' -
4"
LEVER HARDWAREAS PER TASREQUIREMENTS
BRAILLE SIGNAGE AS PER ACCESSIBILITY REQ.
MIN. 1/4" THICK H.C.SYMBOL SIGNAGE ASPER TASREQUIREMENT
DEADBOLTHARDWARE
HOLD TO 90°DOOR SWEEP
VERIFY IF LOUVERS/VENT IN DOOR IS REQUIRED PER W/H EQUIPMENT
3' -
8"
ROTON HINGE
PANIC HARDWARE
26" H X 40" WDIAMOND PLATEKICKPLATE
10"
VIEWER "DOORSCOPE"
BOTTOM KICKPLATE 10" SMOOTH UNINTERRUPTED SURFACE
5' -
0"
A - STOREFRONT A2 - STOREFRONT B - RESTROOMS
NOTE: ALL DOORS, ENTRYWAYS, LATCHES, THRESHOLDS, LEVEL FLOOR AREAS RAMPS, ETC., SHALL COMPLY WITH 2009 C.B.C
D - WATERHEATER E - BACKDOOR
T 30"
TO 4
4"
CS0.10
4
T
6
A6.01
6
A6.01
6
A6.01
6
A6.01
8
A6.01
8
A6.01
1
A6.01
1
A6.01
1
A6.01
1
A6.01
3
A6.01
3
A6.01
4
A6.01
2
A6.01
DOOR TYPES
TEMP GLASS WINDOW@ 60" A.F.F. BRONZEANODIZED W/ALUMINUM FRAME12"X12"
4
A6.01
2
A6.01
C - OFFICE /HALLWAY
GYPSUM BOARD
STUDS AT JAMB TYP.
16 GA. WELDEDH.M. FRAME PAINT COLORTO MATCH ADJACENTWALL SURFACE. TYPICALU.N.O.
2" 5/8"1/
2"
TYP
.
NOTE:SEE ROOM FINISH SCHEDULE AND INTERIOR ELEVATIONS FOR WALL FINISHES
STOP
JAMB
DOOR PER SCHEDULE
TILE FLOOR PERSCHEDULE
1"
F.R.P. PANELING OVER5/8" TYPE 'X' W.R. GYP. BD.
EXT. BRICK VENEER(OR STONE SEE ELEV.) & VAPOR BARRIER MEMBRANE
6X @ HEAD CONDITION
2-2X6 @ JAMB CONDITION
26 GA. G.I. FLASHING@ HEAD CONDITION ONLY
BACKER ROD & CAULKING
1X NAILERHOLLOW METAL DOORFRAME - ATTACH PERMANUFACT. RECMD.
HOLLOW METAL DOORSEE SCHEDULE
STEEL DOOR PER PLAN BOTTOM W/ VINYLWEATHERSTRIP
1/2" TILE
METAL THRESHOLD
SLAB PER PLAN
CAULK - MATCHGROUT COLOR
CONTINUOUS CAULK BEAD
1/4" EXPANSION JOINTSILICON
1/2"
MA
X.
1/4"
MA
X.
MAX.
21
DOOR BOTTOM -MODEL: PEMKO - 217AVFINISH: A
1/4" DUAL PANE FULLYTEMPERED GLASS
SET ALUM. SILL INFULL BED OFSEALANT
TILE SLAB
SOLID BOTTOM TRACE
SHOT PINS 2 1/2"EMBEDMENT @ 16" O.C.
CONC. SIDEWALK CONTROL JOINT SEESTRUCT. DWGS.
2"
RE: STRUCTURE
6"
DOOR
DUAL PANE GLAZING
THERMAL BREAK
ALUMINUM FRAME
10"
FLOOR FINISH
METALTHRESHOLD
ALUMINUM DOORAND FRAME
EXPANSIVE MATERIAL
211/
4" M
AX.
1/2"
MA
X.
DOOR TYPE1. G.C. TO PROVIDE CONSTRUCTION CORES DURING JOB. G.C. RESPONSIBLE FOR ALL DOORS, HARDWARE, LOCKSETS, PANIC DEVICES,
ETC. ALL HOLLOW METAL DOOR FRAMES TO BE WELDED (UNLESS MATCHING EXISTING TIMELY FRAMES). ALL LOCKSETS CYLINDERS TO BE ORDERED TO ACCEPT A 6 PIN FALCON IC LOCK CORE. VERIFY WITH OWNER PRIOR TO ORDERING.
2. HOLLOW METAL DOORS AND FRAMES SHALL BE 16 GA. STEEL. HOLLOW METAL FRAMES SHALL BE WELDED TYPE.
3. ALL HARDWARE SHALL BE US 26D UNLESS NOTED.
4. ALL DOORS SHALL BE KEYED ALIKE WITH 6 PIN FALCON INTERCHANGEABLE CORES. U.O.N. (CORES SUPPLIED BY OWNER)
5. ALL MOUNT CLOSER’S ON PUBLIC SIDE.
6. DOORS 1 & 2 TO HAVE STD. MANUFACTURER DOOR PULL SUPPLIED BY DOOR MANUFACTURER.
7. NO THUMB LATCHES OR KEYED CYLINDER DEAD BOLTS ALLOWED ON ANY DOORS UNLESS OPERATED BY A SINGLE ACTION WITH A LEVER.
8. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT. FLUSH BOLTS OR SURFACE BOLTS ARE PROHIBITED.
9. ALL DOORS ARE REQUIRED PANIC HARDWARE FOR OCCUPANT GROUP A-2.
10. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN THE PATH OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, BY PANIC BARS, PUSH-PULL ACTIVATING BARS, OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE OPENING HARDWARE. HANDLES, PULLS, LATCHES, AND LOCKS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE WITH ONE HAND OPERATION AND DOES NOT REQUIRE TWISTING THE WRIST TO OPERATE.
11. THE WIDTH AND HEIGHT OF REQUIRED EXIT DOORWAYS SHALL BE NOT LESS THAN 3’ IN NOMINAL WIDTH BY 6’-8” IN NOMINAL HEIGHT AND SHALL BE CAPABLE OF OPENING SUCH THAT THE CLEAR WIDTH IS NOT LESS THAN 32.”
12. ALL WOOD DOORS TO BE SEALED AT BOTTOM. INCLUDING LAMINATED DOORS.
13. ALL INTERIOR DOORS TO HAVE STAINLESS STEEL KICKPLATES, WIDTH OF DOOR, 10” HT., BOTH SIDES. U.O.N.
14. G.C. TO SUPPLY AND INSTALL NEW STAINLESS STEEL ANTI-GRAFFITI BACK DOOR PANEL ON MEN’S RESTROOM DOOR.
15. G.C. TO PROVIDE SUBMITTALS TO EPL.
16. THE DOOR SHALL SWING TO THE FULLY OPEN POSITION WITH AN OPENING FORCE NOT TO EXCEED 5 POUNDS (INTERIOR AND EXTERIOR DOORS) AND 15 POUNDS (FIRE DOORS) IS APPLIED TO THE LATCH SIDE.
17. HAND—ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN 30” AND 44” ABOVE FLOOR.
18. VERIFY THAT THE HARDWARE HANDLES ON BOTH SIDES OF THE ACCESSIBLE WATER-CLOSET PLUMBING FIXTURE'S STALL/ COMPARTMENT PARTITION SWING DOORS IN THE NEW MAN'S & WOMEN'S RESTROOMS ARE ACCESSIBLE (E.G. - OPEN LEVER ACTION AND/ OR U-SHAPED TYPE WIRE-PULL HANDLES, ECT. - THAT DO NOT FORCE PEOPLE WITH DISABILITIES TO HAVE TO TIGHTLY GRASP AND/ OR TWIST TO OPEN/ CLOSE THE DOOR). PLEASE VERIFY COMPLIANCE ACCORDINGLY PRIOR TO THE REQUIRED ON-SITE ACCESSIBILITY/ USABILITY INSPECTION.
19. DOORS AND DOORWAYS THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH SECTION 404. MANUAL DOORS AND DOORWAYS, AND MANUAL GATES, INCLUDING TICKET GATES, SHALL COMPLY WITH SECTION 404.2.
20. OPERABLE PARTS SHALL COMPLY WITH 309.
1/2" PLYWOOD
HEADER PER PLAN
#12 SCREWS 2 1/2" L.@ 24" O.C.
SHIM AS REQ.
CAULKING W/ BACKER ROD
GALVANIZED SHEET METALFLASHING W/ DRIP - LEG. @ HDRPAINT TO MATCH FRAME
CAULKING
STOREFRONT
THERMAL BREAK
DUAL PANE GLAZING
110' - 0"
BOTTOM OF CANOPY
110' - 3"
FLAS
HIN
G
6" M
IN.
PRINTED TILE PANEL BY VENDOR
CONTINUOUS MOISTURE BARRIER
FLASHING
SEALANT
109' - 2"
TOP OF WINDOW
SEE 6/A1.60 FOR CANOPY DETAIL
PANIC HARDWARE, WHENEVER REQUIRED, SHALL BE EQUIPPED ANDINSTALLED AS FOLLOWED:
1. PANIC HARDWARE SHALL CONTAIN A MINIMUM OF TWO (2) LOCKING POINTS ON EACH DOOR, ONE LOCATED AT THE HEADER, THE OTHER AT THE THRESHOLD OF THE DOOR.
2. ON SINGLE DOORS, PANIC HARDWARE MAY HAVE ONE LOCKING POINT WHICH IS NOT LOCATED AT EITHER THE TOP OR BOTTOM RAILS OF THE DOOR FRAME. THE DOOR SHALL HAVE AN ASTRAGAL CONSTRUCTED OF STEEL 0.125 INCH THICK WHICH SHALL BE ATTACHED WITH NON-REMOVABLE BOLTS TO THE OUTSIDE OF THE DOOR. THE ASTRAGAL SHALL EXTEND A MINIMUM OF SIX (6) INCHES VERTICALLY ABOVE AND BELOW THE LATCH OF THE PANIC HARDWARE. THE ASTRAGAL SHALL BE A MINIMUM OF TWO (2) INCHES WIDE AND EXTEND A MINIMUM OF ONE INCH BEYOND THE EDGE OF THE DOOR TO WHICH IT IS ATTACHED.
3. DOUBLE DOORS CONTAINING PANIC HARDWARE SHALL HAVE A FULL ASTRAGAL CONSTRUCTED OF STEEL, ATTACHED TO THE DOORS AT THEIR MEETING POINT WHICH WILL CLOSE THE OPENING BETWEEN THEM, BUT NOT INTERFERE WITH THE OPERATION OF EITHER DOOR.
DOOR HARDWARE NOTES
HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON DOORS AND GATES SHALL COMPLY WITH 309.4. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX. AFF. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES.
EXCEPTIONS:1. EXISTING LOCKS SHALL BE PERMITTED IN ANY LOCATION AT EXISTING GLAZED DOORS WITHOUT STILES, EXISTING OVERHEAD ROLLING DOORS OR GRILLES, AND SIMILAR EXISTING DOORS OR GRILLES THAT ARE DESIGNED WITH LOCKS THAT ARE ACTIVATED ONLY AT THE TOP OR BOTTOM RAIL.2. ACCESS GATES IN BARRIER WALLS AND FENCES PROTECTING POOLS, SPAS, AND HOT TUBS SHALL BE PERMITTED TO HAVE OPERABLE PARTS OF THE RELEASE OF LATCH ON SELF-LATCHING DEVICES AT 54" MAX. AFF. PROVIDED THE SELF-LATCHING DEVICES ARE NOT ALSO SELF-LOCKING DEVICES AND OPERATED BY MEANS OF A KEY, ELECTRONIC OPENER, OR INTEGRAL COMBINATION LOCK.
TOILET COMPARTMENT DOORS, INCLUDING DOOR HARDWARE, SHALL COMPLY WITH 404 EXCEPT THAT IF THE APPROACH IS TO THE LATCH SIDE OF THE COMPARTMENT DOOR, CLEARANCE BETWEEN THE DOOR SIDE OF THE COMPARTMENT AND ANY OBSTRUCTION SHALL BE 42 INCHES MIN. DOORS SHALL BE LOCATED IN THE FRONT PARTITION OR IN THE SIDE WALL OR PARTITION FARTHEST FROM THE WATER CLOSET. WHERE LOCATED IN THE FRONT PARTITION, THE DOOR OPENING SHALL BE 4" MAX. FROM THE SIDE WALL OR PARTITION FARTHEST FROM THE WATER CLOSET. WHERE LOCATED IN THE SIDE WALL OR PARTITION, THE DOOR SHALL BE SELF-CLOSING. A DOOR PULL COMPLYING WITH 404.2.7 SHALL BE PLACED ON BOTH SIDES OF THE DOOR NEAR THE LATCH. TOILET COMPARTMENT DOORS SHALL NOT SWING INTO THE MIN. REQUIRED COMPARTMENT AREA.
1. DIMENSIONS ARE APPROXIMATE INCLUDING FRAMES. FIELD VERIFY ALL DIMENSIONS FOR ALL WINDOWS.
2. ALL WINDOW LESS THEN 16'-0" FROM GRADE SHALL BE TEMPERED GLASS. PER 2012 IBC.
3. STOREFRONT FRAME FINISH SHALL BE DARK BRONZE - SEE SPECIFICATIONS.
4. GLASS SPEC: REFER TO ENERGY COMPLIANCE REPORT. 1” LOW-E 1/4” CLEAR ANNEALED GLASS WITH SOLARBAN 70XL (2% LOW E-COATING ON INSIDE SURFACE AT OUTBOARD LIGHT),1/2” AIR SPACE, 1/4” CLEAR INBOARD LIGHT. U-VALUE =.29, SHGC=.39. ASSEMBLY SHALL COMPLY WITH 2012 IBC.
6. WINDOW ”E” IS A SELF CLOSING PASS-THRU SERVICE WINDOW WHICH WILL BE SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR. E1 - READY ACCESS - AA100; 275 SINGLE PANEL SLIDER WINDOW W/ ATTACHED SPLIT DOUBLE TRANSOM FOR AA100 FLYFAN (RESTRICTED OPENING CONFIGURATION) MANUAL OPEN/ SELF CLOSING OPERATION. SEE SHELF. CONTACT E2 - READY ACCESS-AA100; 275 SINGLE PANEL SLIDER WINDOW W/ ATTACHED 16"H SPLIT TRANSOM FOR AA100 FLYFAN. MANUAL OPEN/ SELF CLOSING OPERATION.CONTACT: ANNA ELLIS OR KELLY - 1.800.621.5054. G.C. TO REQUEST EPL PRICING FOR READY ACCESS A/T WINDOWS.
WINDOW HARDWARE NOTES
CAN SYSTEM OR SUB-SEAL@ BOTTOM MULLION
NOTE: ACTIVE LEAF SHALL BE ON THE KITCHEN SIDE OF THE BUILDING (SIDE AWAY FROM THE
DINING ROOM) G.C. TO CONFIRM DIRECTION WITH SUB-CONTRACTOR PRIOR TO ORDERING.
EQ. 6' -2 1/2". EQ.
9' - 7 1/2".
9' -
2"
8' -
0"1'
- 2"
DOOR A2
16' - 2"
EQ EQ EQ EQ
B C
D
A5.63
8
T T T T
13' - 9 1/2". E
B
T T
7
A6.01
7
A6.01
8
A6.01
7
A6.01
7
A6.01
6
A6.01
8
A6.01
8
A5.63
6
A5.637
A6.01
WINDOW TYPE
8' -
0"
10' -
0"
T = TEMPERED GLASS
EQEQEQEQEQ
18' - 4 1/2"
TTTT
A
6
A6.01
7
A6.01
7
A6.01
8
A6.01
DOOR A
DRIVE-THRU WINDOW REQUIRED PER STATE.VERIFY TYPE PRIOR TO ORDER/INSTALL.
E
CENTER
J一BOX ON
ACTIVE LEAFS.S. SHELFBY EPL
AIR CURTAININ TRANSOMWINDOW
OUTSIDE CALIFORNIAE2
FOR ADDITIONAL INFO. SEE
3' - 7 3/4"
RO
UG
H O
PEN
ING
1' -
0"
1 1/
2"
NO
MIN
AL
5' -
0"
AIR CURTAINABOVE
TRANSOMBY G.C.
OPENING NOTEXCEED 432" SQ(IN CALIF.)
STAINLESSSTEEL SHELF
CENTER
J一BOX ON
ACTIVE LEAF
CALIFORNIA ONLY
CLR. OPENING
1' - 7"
1 1/
2"5'
- 0"
IN C
ALIF
.
2' -
6"
4' - 0"
E1
ACTIVE LEAF TO BE ON KITCHEN SIDE (REAR) OF RESTAURANT
NOTE: SHOWN FROM EXTERIOR
2' -
10 1
/2"
2' -
10 1
/2"
8
A5.63
6
A5.637
A6.01
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A6.01
XXXXX
BID & PERMIT
XX-XX-XX
WINDOW & DOORSCHEDULES
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
DOOR SCHEDULE
IDENTITY
Name
DOOR FRAME
FIRERATING
HARDWARESET
NUMBER COMMENTSDOORMARK
SIZE
MATERIAL TYPE FINISH MATERIAL FINISHWIDTH HEIGHT THICKNESS
101 DINING 3' - 0" 8' - 0" 1 3/4" ALUM. A DARKBRONZE
ALUM DARKBRONZE
N/A 1 PROVIDE PUSH AND PULL SIGN W/ PANICHARDWARE. PROVIDE 1"HT. LETTERS ABOVE DOORTO READ "THIS DOOR TO REMAIN UN-LOCKED WHEN
BUILDING IS OCCUPIED"
102 CUSTOMERPICK-UP
6' - 0" 8' - 0" 1 3/4" ALUM A2 DARKBRONZE
ALUM DARKBRONZE
N/A 2 PROVIDE PUSH AND PULL SIGN W/ PANICHARDWARE. PROVIDE 1"HT. LETTERS ABOVE DOORTO READ "THIS DOOR TO REMAIN UN-LOCKED WHEN
BUILDING IS OCCUPIED"
103 KITCHEN 3' - 0" 7' - 0" 1 3/4" S.C. WOOD C PT-3 H.M. PT-3 N/A 3 SELF CLOSING / TIGHT FITTING / 12" X 12" CLR. GLASSIN DOOR, UNDERCUT DOOR 1". VERIFY LAM. SPEC. W/
EPL. LAM. BOTH SIDES. CLOSER'S MOUNT ONPRIVATE SIDE.
104 WOMENS 3' - 0" 7' - 0" 1 3/4" S.W.C. (ALT.HPL)
B PT-3 H.M. PT-3 N/A 4 VERIFY LAM SPEC. W/ EPL LAM. BOTH SIDESPAINT/SEAL HINGE SIDE, TOP, & BOTTOM OF DOORS/TIGHT FITTING. ALL CLOSER'S MOUNT ON PRIVATE
SIDE. DOOR TO HAVE STAINLESS STEEL KICKPLATES,WIDTH OF DOOR, 10" HT., BOTH SIDES.
105 MENS 3' - 0" 7' - 0" 1 3/4" S.W.C. (ALT.HPL)
B PT-3 H.M. PT-3 N/A 4 VERIFY LAM SPEC. W/ EPL LAM. BOTH SIDESPAINT/SEAL HINGE SIDE, TOP, & BOTTOM OF DOORS/TIGHT FITTING. ALL CLOSER'S MOUNT ON PRIVATE
SIDE. DOOR TO HAVE STAINLESS STEEL KICKPLATES,WIDTH OF DOOR, 10" HT., BOTH SIDES.
106 WATERHEATER
3' - 0" 7' - 0" 1 3/4" H.M. D PT-6 @INTERIOR,SEE ELEV
H.M. SEEELEV.
N/A 7 PROVIDE 6"X12" LOUVER @ BOTTOM OF DOOR(W/10'H X 14'W LOUVER IN WALL ABOVE DOOR.)
107 REARKITCHENDELIVERY
3' - 6" 7' - 0" 1 3/4" H.M. E SEE ELEV. H.M. SEEELEV.
N/A 5 INTERIOR, PT-4 W/ PANIC HARDWARE
108 WORKAREA
3' - 0" 7' - 0" 1 3/4" H.M. C PT-6 BOTHSIDES
H.M. PT-6 N/A 6 SELF CLOSING / TIGHT FITTING / 12"X12" ONE WAYGLASS IN DOOR UNDERCUT DOOR 1".
3" = 1'-0"2
HEAD / JAMB DETAIL 3" = 1'-0"
4DOOR SILL
3" = 1'-0"1
EXTERIOR DOOR HEAD/JAMB 6" = 1'-0"
3EXTERIOR DOOR SILL
3" = 1'-0"8
ALUM. STOREFRONT SILL
3" = 1'-0"6
ALUM. STOREFRONT HEADER/JAMB
3" = 1'-0"5
ALUM. STOREFRONT DOOR SILL
WINDOW SCHEDULE
TYPESIZE
HEAD HT.DETAILS
REMARKSW. HT. THICKNESS FRAME GLASS
A 21' - 6" 9' - 8" 1 3/4" 9' - 8" ALUM 1/4" TEMP SEE NOTES &SPECS
B 17' - 6" 10' - 0" 1 3/4" 9' - 8" ALUM 1/4" TEMP SEE NOTES &SPEC.'S
C 15' - 0" 10' - 0" 1 3/4" 9' - 8" ALUM 1/4" TEMP SEE NOTES &SPEC.'S
D 11' - 0 1/2" 9' - 2" 1 3/4" 9' - 2" ALUM 1/4" TEMP SEE NOTES &SPEC.'S BRAKEMETAL INSETINFILLED ATMULLIONS
3" = 1'-0"7
ALUM. WINDOW HEADER/JAMB
REVISIONS
NO. DATE DESCRIPTION
9' - 8"
UPDATE
NOTE: BACKING SUBJECT TO VERIFICATION OF CONDITION OF ITEMS IN FIELD
B
A
A D A
F
D
B
E
CC
I
A
A
C
C
C
A
2' -
8 1/
2"
8' -
0"
C
2' - 4"
3' -
0"4"
4' -
0"
A
I 4' -
4"
F
2' -
8 1/
2"
DINING
100
SALSA BAR
100a
CUSTOMER PICK-UP
101
COOLER
107
STORAGE
106
MENS
111
WOMENS
110
VESTIBULE
113
OFFICE
105
WATER HEATER
114
E
A5/8" PLY CDX 3' - 0" TO 7' - 0" A.F.F.
5/8" PLY CDX 1' - 6" A.F.F. TO 7' - 0" A.F.F.
2X SOLID WOOD AT GRAB BARS, PARTITIONS AND LADDER
5/8" CDX 1' - 0" TP 9' - 0" A.F.F.
5/8" PLY CDX 2' - 6" A.F.F. TO 8' - 6" A.F.F.
5/8" PLY CDX 5' - 6" A.F.F. TO 9' - 6" A.F.F.
5/8" FIRE RATED CDX 0' - 0" TO 1' - 6" A.F.F.
5/8" FIRE RATED CDX 4' - 0" A.F.F. TO BOTTOM OF HOOD
5/8" CDX 6' - 8" TO 9' - 0" A.F.F.
B
C
D
E
F
G
H
I
NOT USED
NOT USED
106 West 11th StreetSuite 1900Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
A7.00
XXXXX
BID & PERMIT
XX-XX-XX
BACKING PLAN
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/4" = 1'-0"1
BACKING PLAN
BACKING LEGEND
REVISIONS
NO. DATE DESCRIPTION
GENERAL1. ALL DESIGN AND CONSTRUCTION SHALL COMPLY WITH THE 2012 INTERNATIONAL BUILDING CODE AND ALL APPLICABLE LOCAL
ORDINANCES.
2. ALL CONSTRUCTION SHALL COMPLY WITH THE PROVISIONS OF FOLLOWING CODES, STANDARDS AND SPECIFICATIONS (LATEST EDITIONS, U.N.O.), EXCEPT WHERE NOTED TO THE CONTRARY ON DRAWINGS AND SPECIFICATIONS OR WHERE MORE STRINGENT REQUIREMENTS ARE SPECIFIED OR SHOWN:
ACI 117 - "STANDARD SPECIFICATIONS FOR TOLERANCE FOR CONCRETE CONSTRUCTION AND MATERIALS" ACI 301 - "SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS" ACI 318 - "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" AISC - "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" AISI - "SPECIFICATIONS FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS" AWS D1.1 - "STRUCTURAL WELDING CODE - STEEL"
3, STRUCTURAL ELEMENTS ARE NON-SELF SUPPORTING AND REQUIRE INTERACTION WITH OTHER ELEMENTS FOR STABILITY AND RESISTANCE TOLATERAL FORCES. FRAMING AND WALLS SHALL BE TEMPORARILY BRACED BY THE CONTRACTOR UNTIL PERMANENT BRACING, FLOOR ANDROOF DECKS, AND WALLS HAVE BEEN INSTALLED AND CONNECTIONS BETWEEN THESE ELEMENTS HAVE BEEN MADE.
4. THE SIZE AND LOCATION OF ALL EQUIPMENT PADS AND PENETRATIONS THROUGH THE STRUCTURE FOR MECHANICAL, ELECTRICAL, AND PLUMBING WORK SHALL BE VERIFIED BY THE CONTRACTOR. PENETRATIONS SHALL BE SUBJECT TO APPROVAL BY THE ARCHITECT AND STRUCTURAL ENGINEER. RE: MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS FOR OPENING LOCATIONS NOT SHOWN ON THE STRUCTURAL DRAWINGS.
5. DO NOT SCALE DRAWINGS.
6. ALL FABRICATIONS OF PREFABRICATED STRUCTURAL MATERIALS MUST BE APPROVED APPROVAL/ACCEPTANCE OF THE FABRICATORS BY THE CITY OF JURISDICTION. INSPECTION SERVICES MUST BE OBTAINED PRIOR TO BEGINNING FABRICATION.
7. FRAMING CONDITIONS NOT SPECIFICALLY SHOWN OR INDICATED SHALL BE FRAMED SIMILAR TO DETAILS SHOWN FOR THE RESPECTIVE MATERIAL OR CONDITIONS.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS BEFORE STARTING WORK AND REPORT ANY DISCREPANCIES TO THE ARCHITECT.
9. WITHOUT EXCLUSION OF ANY REFERENCE IN THE CONSTRUCTION DOCUMENTS TO ANY RULE OR REGULATION, THE STRUCTURAL ENGINEER IS NOT ASSUMING ANY PROVISIONS OF SUPERVISION OF CONSTRUCTION METHODS OR PROCESSES.
10. SUBMITTALS FOR DEFERRED SUBMITTAL ITEMS SUCH AS [WOOD ROOF TRUSSES, AWNINGS, AND CANOPIES] SHALL BE SUBMITTED AND APPROVED BEFORE INSTALLATION CAN BEGIN.
CONCRETE
1. CAST-IN-PLACE CONCRETE CONSTRUCTION SHALL CONFORM TO THE LATEST AMERICAN CONCRETE INSTITUTE DOCUMENTS, ACI-301, 305, 306, 315, 318 AND 347 UNLESS OTHERWISE NOTED IN THESE CONTRACT DOCUMENTS.
2. ALL CONCRETE, UNLESS OTHERWISE NOTED, SHALL DEVELOP A 28 DAY COMPRESSIVE STRENGTH AND HAVE MAXIMUM WATER/CEMENT RATIOS AS FOLLOWS:FOOTINGS, PIERS, GRADE BEAMS, WALLS: 2500 PSI (w/c < 0.58)SLABS-ON-GRADE: 2500 PSI (w/c < 0.50) - REQUIRED FOR STAINED/POLISHED CONCRETE
3. CONCRETE EXPOSED TO WEATHER, VEHICLES AND/OR DEICING CHEMICALS SHALL BE AIR-ENTRAINED WITH 6% (+/-) 1.5% ENTRAINED AIR BY VOLUME AT POINT OF DISCHARGE. DO NOT ALLOW AIR CONTENT OF TROWELED FINISHED FLOORS TO EXCEED 3%.
4. NORMAL WEIGHT AGGREGATES SHALL COMPLY WITH ASTM C33, CLASS 3S COARSE AGGREGATE OR BETTER, GRADED. PROVIDE AGGREGATES FROM A SINGLE SOURCE.A.) MAXIMUM COARSE AGGREGATE SIZE IS 1/2 INCH NOMINAL.B.) FINE AGGREGATE SHALL BE FREE OF MATERIALS WITH DELETERIOUS REACTIVITY TO ALKALI IN CEMENT.C.) COMBINED AGGREGATE GRADATION SHALL BE AS FOLLOWS: WELL GRADED FROM COARSEST TO FINEST WITH NOT MORE THAN 18 % AND NOT LESS THAN 8 %
RETAINED ON AN INDIVIDUAL SIEVE, EXCEPT THAT LESS THAN 8 % MAY BE RETAINED ON THE COARSEST SIEVE AND THE #50 AND FINER SIEVES.
5. THE CONCRETE SLAB-ON-GRADE HAS BEEN DESIGNED FOR ITS FINAL USE AND NOT FOR CONSTRUCTION CONSIDERATIONS. CONTRACTOR SHALL COORDINATE THE SLAB DESIGN WITH CONSTRUCTION NEEDS. THE SLAB DESIGN INDICATED ON THESE DRAWINGS IS TO BE CONSIDERED A MINUMUM. SUBMIT CHANGES TO THE SLAB DESIGN TOTHE ENGINEER OF RECORD FOR REVIEW.
6. IT IS THE INTENT OF THESE CONCRETE SPECIFICATIONS THAT THE CONTRACTOR SUPPLY CONCRETE MIXES WITH A MINIMUM AMOUNT OF WATER IN ORDER TO LIMIT PLASTIC SHRINKAGE CRACKING IN FRESHLY PLACED CONCRETE. IT IS EXPECTED THAT PRODUCING WORKABILITY FOR CONCRETE MIXES WILL REQUIRE THE ADDITION OFWATER-REDUCING AND/OR SUPER-PLASTICIZING CHEMICAL ADMIXTURES.
7. CONCRETE SLUMP SHALL BE A MAXIMUM OF 4" +/- 1" (ASTM C-143) AS DELIVERED IN THE FIELD. CONTRACTOR MAY USE CHEMICAL ADMIXTURES TO ATTAIN A MAXIMUMSLUMP OF 8" FOR WORKABILITY.
8. NO WATER MAY BE ADDED TO THE CONCRETE MIX ON SITE.
9. FLY ASH MAY BE USED AT A RATE NOT TO EXCEED 15% OF THE TOTAL CEMENT CONTENT.
10. CHAMFER ALL EXPOSED CORNERS OF CONCRETE WALLS, BEAMS, AND COLUMNS 3/4".
11. ALL CONTROL JOINTS IN CONCRETE SLABS-ON-GRADE SHALL BE CUT TO 1/3 OF THE DEPTH. CUT JOINTS AS SOON AS POSSIBLE AFTER CONCRETE HAS BEEN PLACEDWITHOUT DISLODGING AGGREGATE, OR USE KEYED COLD JOINT.
12. THE UNIT POUR FOR SLABS AND WALLS SHALL NOT EXCEED 100 LINEAL FEET IN ANY ONE DIRECTION. CUT SLABS TO 1/3 THE DEPTH ON GRID LINES INTO AREAS OF ABOUT150 SQUARE FEET.
13. PRIOR TO PLACING CONCRETE IN ANY LOCATION, IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO HAVE THOROUGHLY CHECKED AND COORDINATED ALL DIMENSIONS, ELEVATIONS, OPENINGS, RECESSES, AND BLOCKOUTS SHOWN ON THE ARCHITECTURAL, STRUCTURAL, AND MECHANICAL DRAWINGS. IN THE EVENT ERRORS, CONFLICTS, OR OMISSIONS EXIST, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE ARCHITECT OR ENGINEER FOR NECESSARY CORRECTIVE ACTION.
14. EMBEDDED ITEMS ARE TO BE FURNISHED AND INSTALLED BY THE CONTRACTOR PRIOR TO PLACING CONCRETE.
15. ANCHOR RODS SHALL BE HELD IN PLACE WITH A RIGID TEMPLATE.
STEEL
1. ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED, AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, LATEST EDITION AND AISC CODE OF STANDARD PRACTICE.
2. ALL STRUCTURAL STEEL FOR WIDE FLANGE & WT SHAPES SHALL BE A992 GRADE 50 UNLESS NOTED OTHERWISE ON THE PLANS. ALL ANGLES, PLATES, AND CHANNELS AND SHALL BE ASTM A36 UNLESS NOTED OTHERWISE. ALL RECTANGULAR AND ROUND HSS SHAPES SHALL BE ASTM A500, GRADE B.
3. ALL BOLTS SHALL BE 3/4" DIAMETER A-307 BOLTS WITH HEAVY HEX HEADS, UNLESS NOTED OTHERWISE ON DRAWINGS. ALL CONNECTIONS SHALL HAVE A MINIMUM OF TWO 3/4" DIAMETER BOLTS, SNUG-TIGHTENED TYPE CONNECTIONS UNLESS NOTED OTHERWISE IN THEDOCUMENTS.
4. ALL STRUCTURAL STEEL WELDS IN THE SHOP OR THE FIELD SHALL BE PERFORMED BY A QUALIFIED WELDER AND SHALL CONFORM TO THE CURRENT REQUIREMENTS OF A.W.S.
5. SHOP WELDED AND FIELD BOLTED CONNECTIONS ARE PREFERRED, UNLESS OTHERWISE SHOWN.
6. FILLET WELDS NOT SPECIFICALLY SIZED IN THESE DOCUMENTS SHALL BE THE MINIMUM SIZE IN ACCORDANCE WITH AWS D1.1 LATEST EDITION, DEPENDENT ON THE THINNER PART JOINED, BUT NO LESS THAN 3/16”.
7. WELDING ELECTRODES SHALL BE E70XX WITH MINIMUM CHARPY V-NOTCH TOUGHNESS (CVN) OF 20 FT-LB AT -20 DEGREES.
8. THE CONTRACTOR SHALL PROVIDE SHELF ANGLES, GLASS SUPPORTS, LINTELS AND OTHER MISCELLANEOUS STEEL, AS SHOWN ON THE DRAWINGS AND AS REQUIRED TO PROVIDE SUPPORT (STABILIZATION) AROUND AND THROUGHOUT THE BUILDING. NOT EVERY DETAIL IS SHOWN. SEE ARCHITECTURAL AND ELEVATOR DRAWINGS FOR ADDITIONAL MISCELLANEOUS STEEL DETAILS.
9. ALL BRICK LEDGER ANGLES AND LINTEL BEAMS WITHIN EXTERIOR WALLS SHALL BE HOT DIPPED GALVANIZED IN ACCORDANCE WITH ASTM A123.
POST INSTALLED ANCHORS
1. ALL POST INSTALLED ANCHORS SHALL MEET THE REQUIREMENTS OF ACI 318, APPENDIX D AND SHALL BE ACCEPTABLE FOR BOTH CRACKED AND UNCRACKED CONCRETE.
2. EXPANSION ANCHORS SHALL BE POWER-STUD + SD2 (ICC ESR 2502) ANCHORS UNLESS NOTED OTHERWISE. MINIMUM EMBEDMENT UNLESS NOTED OTHERWISE SHALL BE:
A.) 3 5/8" FOR 1/2" DIAMETER ANCHORSB.) 4 1/2" FOR 5/8" DIAMETER ANCHORSC.) 5 3/8" FOR 3/4" DIAMETER ANCHORS
3. ADHESIVE ANCHORS SHALL BE F1554-36 THREADED ROD ANCHORS UNLESS NOTED OTHERWISE. EMBEDMENT OF ANCHOR SHALL BE IN ACCORDANCE WITH POWER FASTENER SPECIFICATIONS FOR F1554-36 THREADED RODS:
A.) 3 1/2" FOR 1/2" DIAMETER ANCHORSB.) 4" FOR 5/8" DIAMETER ANCHORSC.) 5 1/4" FOR 3/4" DIAMETER ANCHORS
4. ADHESIVE ANCHORS SHALL USE POWER FASTENERS AC110+ GOLD ADHESIVE IN SOLID CONCRETE UNLESS NOTED OTHERWISE ON THE DRAWINGS.
5. EMBEDMENT DEPTH SHALL BE DEFINED AS THE DISTANCE FROM THE SURFACE OF THE LOAD-BEARING BASE MATERIAL TO THE DEEPEST PART OF THE ANCHOR AFTER THE ANCHOR HAS BEEN DRIVEN INTO THE HOLE BUT NOT YET EXPANDED.
6. ADHESIVE ANCHORS SHALL BE ACCEPTABLE FOR LONG-TERM LOADING. ONLY NON-EPOXY BASED ADHESIVES SHALL BE USED WHEN BASE MATERIAL TEMPERATURES ARE BELOW 40 DEG F.
7. POST INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE DRAWINGS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE ENGINEER PRIOR TO USING POST INSTALLED ANCHORS FOR MISSING OR MISPLACED C.I.P. ANCHORS. CARE SHALL BE TAKEN
TO AVOID CONFLICTS WITH EXISTING REINFORCING BARS. HOLES SHALL BE DRILLED AND CLEANED PER ANCHOR MANUFACTURER’S SPECIFICATIONS.
8. EQUIVALENT ANCHORS MAY BE SUBMITTED FOR THE ENGINEERS APPROVAL. SUBMITTALS ARE THE CONTRACTOR’S RESPONSIBILITY AND MUST INCLUDE EVALUATION REPORTS FROM THE INTERNATIONAL CODE COUNCIL.
9. STAINLESS STEEL ANCHORS ARE REQUIRED AT ALL EXPOSED WEATHER CONDITIONS.
1. ALL REINFORCING STEEL SHALL BE ASTM A615 GRADE 60, EXCEPT WELDED REINFORCING WHICH SHALL BE ASTM A706 GRADE 60.
2. ALL WELDED WIRE FABRIC SHALL BE ASTM A185 AND A82 COLD DRAWN WIRE.
3. ALL ACCESSORIES FOR SUPPORTING REINFORCING SHALL BE GALVANIZED OR HAVE PLASTIC-COATED FEET.
4. PROVIDE CORNER BARS AT THE EXTERIOR FACE OF ALL WALL AND FOOTING CORNERS EQUAL TO HORIZONTAL BARS.
5. PROVIDE AT LEAST TWO VERTICAL #5 BARS AT ALL STEPS IN FOUNDATION WALLS, FOOTINGS, AND GRADE BEAMS.
6. REINFORCING SHALL BE DETAILED, FABRICATED, PLACED, AND SUPPORTED IN ACCORDANCE WITH ACI 315, LATEST EDITION.
7. STANDARD COVERAGE OF REINFORCING, UNLESS OTHERWISE SHOWN, SHALL BE AS FOLLOWS:
CAST AGAINST EARTH, PERMANENTLY EXPOSED TO WEATHER _______ 3"EXPOSED TO EARTH & WEATHER (FORMED) ______________________ 2"
NOT EXPOSED TO EARTH OR WEATHER: SLABS, WALLS ____________ 3/4" BEAMS AND COLUMNS___________________________________________ 1-1/2"
8. ALL LAP SPLICES SHALL BE CLASS B UNLESS NOTED OTHERWISE.
9. FOR REINFORCING BAR LAP LENGTHS IN CONCRETE, SEE DETAIL 2 ON S2.
REINFORCING STEEL
STANDARD
AB : ANCHOR BOLTA.F.F. : ABOVE FINISHED FLOORALT. : ALTERNATEALUM : ALUMINIUMAPA : AMERICAN PLYWOOD ASSOC.& : AND@ : AT
B.O.F. : BOTTOM OF FOOTINGBLDG. : BUILDINGBLK'D : BLOCKEDBLKG : BLOCK(ING)BLW : BELOWBOT. : BOTTOMBM : BEAMB.N. : BOUNDARY NAILINGBRDG. : BRIDGINGBS : BOTH SIDES
C.C.J. : CRACK CONTROL JOINTCDX : EXTERIOR GRADE PLYWOODCIP : CAST IN PLACEC.O.G. : CENTER OF GRAVITYC.L. : CENTER LINEC.N. : COMMON NAILCOL. : COLUMNCONC. : CONCRETECONST. : CONSTRUCTION
d : PENNY NAILSD.B.A. : DEFORMED BAR ANCHORDBL : DOUBLEDF : DOUGLAS FIRDET. : DETAILDIA. : DIAMETERDIM. : DIMENSIONDWG. : DRAWING
E.F. : EACH FACEE.J. : EXPANSION JOINTELEV. : ELEVATIONEQ. : EQUALE.W. : EACH WAYEXP. : EXPANSIONEXT. : EXTERIOREXIST. : EXISTING
FAB : FABRICATIONFDN. : FOUNDATIONF.F. : FINISHED FLOORFN : FIELD NAILF.S. : FAR SIDEFT (') : FOOT (FEET)FTG. : FOOTING
GA : GAUGE (THICKNESS)G.B. : GRADE BEAMGLB : GLUE LAMINATED BEAMGYP. BD. : GYPSUM BOARD
(H) : HORIZONTALHORIZ. : HORIZONTALHT. : HEIGHT
I.D. : INSIDE DIAMETERIN. (") : INCH(ES)INSUL. : INSULATIONINT. : INTERIOR
JT. : JOINT
k : KIPS (1,000 POUND FORCE)KP : KING POSTKS : KING STUD
LB (#) : POUND(S) FORCEL.B. : LAG BOLTLG. : LONGLLH : LONG LEG HORIZONTALLLV : LONG LEG VERTICALLLBB : LONG LEG BACK-TO-BACKLSL : TIMBERSTRAND BEAM
MAS : MASONRYMAX. : MAXIMUMMIN. : MINIMUMML : MICROLLAMM.B. : MACHINE BOLT
NOM. : NOMINALN.S. : NEAR SIDEN.T.S. : NOT TO SCALE
O.C. : ON CENTERO.D. : OUTSIDE DIAMETEROPT : OPTIONAL
PL. : PLATEPLY : PLYWOODPSF : POUNDS PER SQUARE FOOTPSI : POUNDS PER SQUARE INCH
R. : RADIUSR.D. : ROOF DRAINREINF. : REINFORCINGR.O. : ROUGH OPENING
SCH. : SCHEDULESDWS : SELF DRILLING WOOD SCREWS.F. : SQUARE FEETSHT. : SHEETSIM. : SIMILARS.L. : STRUCTURAL LINESLBB : SHORT LEG BACK-TO-BACKSPEC. : SPECIFICATIONSSTL. : STEELSTR 1 : STRUCTURAL #1
T.S. : TUBE STEELTN : TOE NAILT.O.B. : TOP OF BEAMT.O.C. : TOP OF CONCRETET.O.F. : TOP OF FOOTINGT.O.G. : TOP OF GIRDERT.O.J. : TOP OF JOISTT.O.M. : TOP OF MASONRYT.O.P. : TOP OF PIERT.O.S. : TOP OF SHEATHINGT.O.SLAB : TOP OF SLABTYP. : TYPICALT PL. : TOP PLATE
U.N.O. : UNLESS NOTED OTHERWISE
VERT. : VERTICAL
W.W.F. : WELDED WIRE FABRIC
DESIGN CRITERIA
1. BUILDING CODE & LOCAL AMENDMENTS 2012 IBC
2. DEAD LOADS A. ROOF (INCLUDING COLLATERAL) LOAD 20 PSF
3. LIVE LOADSA. ROOF (REDUCIBLE) 20 PSFB. SLAB ON GRADE 100 PSF
4. SNOW LOADS A. GROUND SNOW LOAD, Pg (BASE) 0 PSF
5. WIND LOADSA. ULTIMATE DESIGN WIND SPEED, Vult 115 MPHB. NOMINAL DESIGN WIND SPEED, Vasd 89.1 MPHB. RISK CATEGORY IIC. WIND IMPORTANCE FACTOR 1.0D. WIND EXPOSURE BE. INTERNAL PRESSURE COEFFICIENT +/- 0.18F. COMPONENTS AND CLADDING (Ae = 75 S.F.) -28.51 PSF (ZONE 5) ULTIMATE / -17.11 PSF (ZONE 5) SERVICE
6. EARTHQUAKE LOADS A. RISK CATEGORY IIB. SEISMIC IMPORTANCE FACTOR, Ie 1.0C. MAPPED SPECTRAL RESPONSE ACCELERATION, Ss 0.163D. MAPPED SPECTRAL RESPONSE ACCELERATION, S1 0.055E. SOIL SITE CLASS DF. DESIGN SPECTRAL RESPONSE COEFFICIENT, Sds 0.174G. DESIGN SPECTRAL RESPONSE COEFFICIENT, SdI 0.088H. SEISMIC DESIGN CATEGORY BI. SEISMIC FORCE RESISTING SYSTEM: LIGHT-FRAMED STRUCTURAL SYSTEM w/ SHEATHING J. DESIGN BASE SHEAR 1.93 kipsK. SEISMIC RESPONSE COEFFICIENT (s), Cs 0.0.027L. RESPONSE MODIFICATION FACTOR (s), R 6.5 M. ANALYSIS PROCEDURE USED EQUIVALENT LATERAL FORCE PROCEDURE
FOUNDATION & SLAB ON GRADE1. FOOTING DESIGNS ARE BASED ON A NET ALLOWABLE SOIL BEARING PRESSURE OF 2,500 PSF FOR SPREAD FOOTINGS AND
CONTINUOUS WALL FOOTINGS. FOOTINGS SHALL BEAR ON EXISTING SUB-GRADE OR ENGINEERED FILL AS DESCRIBED IN THE SOILS REPORT BY: SPEEDIE AND ASSOCATES, GEOTECHNICAL ENGINEERS, PROJECT # [XXXX], DATED [XXXXXX].
2. CONTRACTOR SHALL READ THE SOILS REPORT AND THOROUGHLY FAMILIARIZE HIMSELF WITH THE SITE AND SUB-GRADE INFORMATION GIVEN THEREIN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING EXACT QUANTITIES FOR ESTIMATING AND CONSTRUCTION.
3. ALL EXISTING FOUNDATIONS, IF PRESENT, SHALL BE DEMOLISHED A MINIMUM OF 24 INCHES BELOW BOTTOM OF PROPOSED FOOTINGS.
4. FOOTINGS (INCLUDING STAIR AND RAMP FOUNDATIONS) SHALL BEAR AT OR BELOW MINIMUM BEARING DEPTH. MINIMUM BEARING DEPTH IS 18 INCHES BELOW ADJACENT FINISHED GRADE.
5. SLAB POURS SHALL BE SEPARATED BY A CONSTRUCTION JOINT.
6. CRACK CONTROL JOINTS SHALL BE LOCATED AS SHOWN ON PLANS OR AS DIRECTED BY THE ARCHITECT OR ENGINEER.
7. FOUNDATION WALLS SHALL HAVE ADEQUATE TEMPORARY BRACING BEFORE BACKFILL IS PLACED AGAINST THEM. TEMPORARY BRACING SHALL NOT BE REMOVED UNTIL WALL IS PERMANENTLY BRACED.
8. PRIOR TO FORMING AND PLACING OF THE REINFORCING, ALL EXCAVATIONS SHALL BE INSPECTED BY AND APPROVED BY THE GEO-TECHNICAL ENGINEER.
9. PROVIDE TWO COPIES OF A COMPACTION REPORT CERTIFIED BY THE SOILS ENGINEER. THE REPORTS ARE TO BE SUBMITTED TO AND ACCEPTED BY THE BUILDING DEPARTMENT PRIOR TO CALLING FOR FOUNDATION INSPECTION.
10. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE ALL FOOTINGS AND UTILITY LINE RELATIONSHIPS SO THAT THE REQUIREMENTS OF DETAIL 1/S2 ARE MET. NEW UTILITY LINES SHALL BE LOCATED PRIOR TO FOUNDATION EXCAVATION.
WOOD1. ALL DESIGN AND CONSTRUCTION SHALL CONFORM TO THE APPLICABLE BUILDING CODE AND THE LATEST EDITION OF THE NATIONAL DESIGN
SPECIFICATION FOR WOOD CONSTRUCTION.
2. ALL STUDS AND PLATES SHALL BE SOUTHERN PINE OR DOUGLAS FIR LARCH NO. 2 (19% MAX. MOISTURE CONTENT) OR BETTER.
3. ROOF DECK SHALL BE APA 32/16 SPAN RATED SHEATHING, EXPOSURE 1. ATTACH WITH 8D COMMON OR DEFORMED SHANK NAILS PER ROOF PLAN. STAGGER PANELS AS REQUIRED TO AVOID LINING UP END JOINTS.
4. WOOD PLATES, SILLS AND SLEEPERS WHICH REST ON CONCRETE SLABS, ARE IN DIRECT CONTACT WITH THE EARTH, AND SILLS WHICH REST ON CONCRETE OR MASONRY FOUNDATIONS SHALL BE CCA PRESSURE TREATED WOOD, OR SHALL HAVE APPROVED METAL ATTACHMENT.
5. ALL TRUSSES MUST BE SECURELY BRACED BOTH DURING ERECTION AND PERMANENTLY AS REQUIRED BY THE TRUSS MANUFACTURER. CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY FIELD BRACING TO ASSURE ROOF TRUSSES ARE INSTALLED AT THE PROPER SPACING AND ARE STRAIGHT AND PLUMB.
6. METAL PLATE CONNECTED WOOD TRUSSES SHALL BE DESIGNED, FABRICATED, AND ERECTED IN ACCORDANCE WITH ANSI/TPI -1995. ENGINEERING DRAWINGS AND DESIGN CALCULATIONS SHALL BEAR THE SEAL OF A PROFESSIONAL ENGINEER WHO IS LEGALLY AUTHORIZED TO PRACTICE IN THE JURISDICTION WHERE PROJECT IS LOCATED AND WHO IS EXPERIENCED IN PROVIDING ENGINEERING SERVICES OF THE KIND INDICATED AND SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW PRIOR TO FABRICATION. THE TRUSS FABRICATOR SHALL SUPPLY ALL HARDWARE ANDFASTENERS FOR JOINING MEMBERS SUPPLIED BY THE TRUSS FABRICATORS.
7. ROOF TRUSSES SHALL BE DESIGNED FOR THE STRUCTURAL LOADS INDICATED ON THE STRUCTURAL DRAWINGS.
8. ROOF TRUSSES SHALL BE DESIGNED TO LIMIT THE MAXIMUM LIVE LOAD DEFLECTION TO SPAN/360 AND MAXIMUM TOTAL LOAD DEFLECTION TO SPAN/240.
9. CONTRACTOR SHALL NOT CUT, NOTCH OR BORE HOLES IN WOOD TRUSSES UNLESS APPROVED BY THE WOOD TRUSS DESIGNER.
10. TRUSS BOTTOM CHORDS SHALL BE PERMANENTLY CONNECTED BY BRIDGING. BRIDGING REQUIREMENTS SHALL BE DETERMINED BY THE TRUSS DESIGNER/MANUFACTURER, BUT SHALL CONSIST OF NOT LESS THAN 1-INCH BY 3-INCH LUMBER, DOUBLE NAILED AT EACH TRUSS LOCATION. SPACINGOF BRIDGING SHALL NOT EXCEED 8'-O" O.C.
11. WEB MEMBER PLANE BRIDGING SHALL BE DETERMINED BY THE TRUSS DESIGNER/MANUFACTURER.
12. CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY FIELD BRACING TO ASSURE ROOF TRUSSES ARE INSTALLED AT THE PROPER SPACING AND THAT THEY ARE STRAIGHT AND PLUMB.
13. TRUSS CHORDS SHALL BE FABRICATED OF SOUTHERN PINE OR DOUGLAS FIR LARCH NO.2 (19% MAX. MOISTURE CONTENT) OR BETTER.
14. TRUSS WEB MEMBERS SHALL BE FABRICATED OF SOUTHERN PINE OR DOUGLAS FIR LARCH NO. 2 (19% MAX. MOISTURE CONTENT) OR BETTER.
15. ALL SPECIFIED FASTENERS SHOWN IN THESE DOCUMENTS MUST BE INSTALLED ACCORDING TO THE MANUFACTURERS INSTRUCTIONS. ALL FASTENERS IN A CONNECTION MUST BE USED. ALL FASTENERS MUST BE INSTALLED PRIOR TO LOADING THE CONNECTION.
16. SUBSTITUTIONS FOR SIMPSON STRONG TIE CO., INC’S PRODUCTS MUST BE PRE-APPROVED IN WRITING BY THE ENGINEER OR ARCHITECT. SUBSTITUTION REQUESTS MUST BE ACCOMPANIED BY EVALUATION REPORTS FROM THE INTERNATIONAL CODE COUNCIL.
17. PARALLEL STRAND LUMBER (PSL) MEMBERS SHALL CONFORM TO THE FOLLOWING:E = 2,000,000 PSIFb = 2,900 PSIFv = 285 PSI
1. INSPECTION BY A REGISTERED BUILDING INSPECTOR EMPLOYED BY A TESTING LAB SHALL BE PROVIDED FOR THE ITEMS IN THE TABLE BELOW.
INSPECTION
2. A CERTIFICATE OF SATISFACTORY COMPLETION OF WORK REQUIRING SPECIAL INSPECTION MUST BE COMPLETE & SUBMITTED TO THE FIELD INSPECTION DIVISION.
3. AN APPLICATION FOR OFF-SITE FABRICATION MUST BE SUBMITTED TO THE FIELD INSPECTION DIVISION FOR APPROVAL PRIOR TO FABRICATION.
4. A CERTIFICATE OF COMPLIANCE FOR OFF-SITE FABRICATION MUST BE COMPLETED AND SUBMITTED TO THE FIELD INSPECTION DIVISION PRIOR TO THE ERECTION OF PREFABRICATED COMPONENTS.
MATERIAL, SYSTEM, COMPONENT AND WORK REQUIRED TO HAVE SPEC. INSP.
TYPE OF SPEC. INSP. INSPECTION NOTESCONTINUOUS PERIODIC
STRUCTURAL WOOD:
CONCRETE:
SPECIAL CASES:
SOILS:
NAILING, BOLTING, ANCHORING AND OTHER FASTENING OF COMPONENTS WITHIN THE SEISMIC FORCE RESISTING SYSTEM
SHEARWALLS, DIAPHRAGMS WITH FASTENER SPACING OF THE SHEATHINGIS MORE THAN 4 INCHES
X
NOT REQUIRED
INCLUDING SHEARWALLS, DIAPHRAGMS, DRAG STRUTS,BRACES AND HOLDOWNS.
FOUNDATIONS WITH f'c <= 2500 NOT REQUIREDINSPECTION OF REINF. STEEL INCLUDING PRESTRESSING TENDONS, AND PLACEMENT
VERIFYING USE OF REQUIRED DESIGN MIX
TAKING TEST SAMPLES
X
X
X
INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT
INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMP. AND TECHNIQUE
INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMESIONS OF THE CONCRETE MEMBER BEING FORMED.
X
X
X
ACI 318: 3.5, 7.1-7.7
ACI 318: CHAPTER 4, 5.2-5.4
ACI 318: 5.6, 5.8
ACI 318: 5.9, 5.10
ACI 318: 5.9, 5.10
ACI 318: 6.1.1
EPOXY:SIMPSON 'SET-XP' (ICC-ESR 2500)SIMPSON 'SET' (ICC-ESR 1772)HILTI 'RE 500' (ICC-ESR 2322)HILTI 'HY 200' (ICC-ESR 3187)
AWNING CONSTRUCTIONS
INSPECTION OF FABRICATORS
X
X
X
THE SPECIAL INSPECTOR MUST BE ON THE JOBSITE DURING ANCHOR INSTALLATION TO VERIFY ANCHOR TYPE, CONCRETE COMPRESSIVE STRENGTH, HOLE DIMENSIONS AND CLEANING, SPACING, EDGE DISTANCE AND EMBOEDMENT.
VERIFY MATERIAL BELOW FOOTING AREADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITYVERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIALPERFORM CLASSIFICATION AND TESTING OF CONTROLLED FILL MATERIALVERFIY USE OF PROPER MATERIALS,DENSITIES AND LIFT THICKNESSES DURING PALCEMENT AND PRIOR TO PLACEMENT OF CONTROLLEDFILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY
X
X
X
X
X
SPECIAL INSPECTIONS TABLE
SHOP DRAWINGS
1. CODE COMPLIANT STRUCTURAL DESIGN OF THE FOLLOWING ITEMS IS DEFERRED TO THE GENERAL CONTRACTOR.A.) METAL PLATE CONNECTED WOOD TRUSSESB.) CANOPYC.) AWNING
2. DEFERRED SUBMITTALS SHALL INCLUDE SUBSTANTIATING STRUCTURAL CALCULATIONS AND SHALL BEAR THE SIGNED WET STAMP OF A REGISTERED PROFESSIONAL ENGINEER WHO IS LEGALLY AUTHORIZED TO PRACTICE IN THE JURISDICTION WHERE PROJECT IS LOCATED AND WHO IS EXPERIENCED IN PROVIDING ENGINEERING SERVICES OF THE KIND INDICATED. DEFERRED SUBMITTALS SHALL BEAR THE APPROVAL STAMP OF THE PROJECT ENGINEER OF RECORD.
3. ALL SHOP DRAWINGS AND SUBMITTALS MUST BE REVIEWED AND APPROVED BY THE CONTRACTOR PRIOR TO SUBMITTAL. ENGINEER’S REVIEW OF SHOP DRAWINGS IS LIMITED TO CHECKING FOR GENERAL CONFORMANCE WITH DESIGN DRAWINGS AND STRENGTH OF COMPONENTS AND MATERIALS. CONTRACTOR IS RESPONSIBLE FOR ANY CHANGES FROM THE DESIGN DRAWINGS, QUANTITIES, DIMENSIONAL ERRORS OR OMISSIONS IN THE SHOP DRAWINGS.
4. ALL SHOP DRAWINGS MUST BE ORIGINAL DOCUMENTS AND SHALL NOT BE REPRODUCTIONS OF THESE CONTRACT DOCUMENTS.
5. SUBMIT SHOP DRAWINGS DETAILING FABRICATION OF EACH MEMBER AND ITS CONNECTIONS. DETAIL DRAWINGS ARE TO BEPREPARED UNDER THE SUPERVISION OF A LICENSED PROFESSIONAL ENGINEER.
6. CONTRACTOR SHALL SUBMIT STRUCTURAL SHOP DRAWINGS FOR THE FOLLOWING:A.) CONCRETE MIX DESIGN AND MATERIALSB.) CONCRETE REINFORCING STEELC.) PREFABRICATED WOOD AND LIGHT GAGE TRUSSES & CONNECTIONSD.) CANOPY AND AWNING CONNECTION DETAILS
LIGHT GAGE METAL FRAMING1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
ALL LIGHT GAGE METAL FRAMING AND CONNECTIONS SHALL BE DESIGNED, FABRICATED, AND ERECTED IN ACCORDANCE WITH AISI “SPECIFICATION FOR THE DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS” AND NAAMM ML/SFA 540 “LIGHTWEIGHT STEEL FRAMING SYSTEMS MANUAL.”
ALL LIGHT GAGE METAL FRAMING IDENTIFICATION SHOWN IN THESE DOCUMENTS IS IN ACCORDANCE WITH THE STEEL STUD MANUFACTURERS ASSOCIATION (SSMA).
ALL STRUCTURAL MEMBERS SHALL BE FORMED FROM STEEL HAVING A GALVANIZED COATING MEETING THE REQUIREMENTS OF ASTM A-653. STEEL MATERIAL SHALL HAVE A MINIMUM YIELD STRESS OF 33 KSI EXCEPT MEMBERS OF 54 MIL THICKNESS OR HEAVIER SHALL HAVE A MINIMUM YIELD STRESS OF 50 KSI.
ALL CONNECTIONS SHALL BE MADE WITH A MINIMUM OF (4) #10-16 SCREWS OR EQUIVALENT WELDS. (UNLESS NOTED OTHERWISE ON THE DRAWINGS)
ALL SCREWS SHALL BE OF THE DIAMETER AND SIZE INDICATED ON THE DRAWINGS, AND SHALL BE THOSE MANUFACTURED AND TESTED BY ITW BUILDEX. MINIMUM SPACING AND EDGE DISTANCE FOR SCREWS SHALL BE THE GREATER OF EITHER 1/2 INCH OR 3 X SHANK DIAMETER, UNLESS NOTED OTHERWISE ON THE DRAWINGS. SCREW PENETRATION THROUGH JOINED MATERIALS SHALL NOT BE LESS THAN THREE EXPOSED THREADS. SELECT SCREWS WITH AN ADEQUATE CUTTING TIP TO ACCOMMODATE THE TOTAL THICKNESS TO BE DRILLED. DRILLING MUST BE COMPLETED BEFORE THE THREADS ENGAGE THE MATERIAL. WHERE SCREW ATTACHMENTS ARE MADE TO FRAMING COMPONENTS OF DIFFERENT THICKNESSES, THE THINNEST COMPONENT MUST BE PENETRATED FIRST. (UNLESS NOTED OTHERWISE) ALL SCREWS ARE TYPE ‘T1'.
DIAGONAL STRAP BRACING SHALL BE ATTACHED AT ALL INTERSECTIONS WITH VERTICAL MEMBERS WITH A #10-16 SCREW OR EQUIVALENT WELDS.
WELDING SHALL BE DONE IN ACCORDANCE WITH AWS D1.3 - LATEST EDITION, STRUCTURAL WELDING CODE, SHEET STEEL.
SUGGESTED WELD METAL AND PROCESS FOR SHOP WELDING ARE: 70 ksi WELD METAL STRENGTH (MINIMUM). SUGGESTED METHODS FOR FIELD WELDING: 1/8" (UNLESS NOTED OTHERWISE) E70XX (MINIMUM) ELECTRODE - SMAW; OR”GASLESS” MIG.
MINIMUM WELD THROAT THICKNESS (t) MUST MATCH OR EXCEED THE BASE STEEL THICKNESS OF THE THINNEST CONNECTED PART UNLESS NOTED OTHERWISE.
WEB STIFFENERS FOR STUD JOISTS SHALL BE PROVIDED AT ALL REACTION POINTS, INTERMEDIATE CONCENTRATED LOADS, AND WHERE INDICATED ON THE DRAWINGS.
SEQUENCING OF WELDS SHALL BE SO AS TO AVOID DISTORTION OF MEMBERS. REPLACE ALL MEMBERS WHEN BURN THROUGH OCCURS DURING WELDING.
ALL FRAMING COMPONENTS SHALL BE CUT SQUARELY FOR ATTACHMENT TO PERPENDICULAR MEMBERS OR AS REQUIRED ON ANGULAR FIT AGAINST ABUTTING MEMBERS. MEMBERS SHALL BE HELD POSITIVELY IN PLACE UNTIL PROPERLY FASTENED.
NO SPLICES IN STUDS, JOISTS, OR OTHER LOAD CARRYING MEMBERS MAY BE MADE WITHOUT PRIOR ENGINEERING REVIEW AND SPECIFIC DETAILS FOR ANY SUCH SPLICE(S).
TRACK MEMBERS SHALL MATCH DEPTH AND MIL THICKNESS (GAGE) OF STUDS UNLESS NOTED OTHERWISE.
PROVIDE HEADERS AND SUPPORTING STUDS FOR FRAMING OF WALL OPENINGS.
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
NOT FOR CONSTRUCTIO
N
S1.00
17XXX
[Project Status]
[Date]
GENERAL NOTES&
ABBREVIATIONS
EL P
OLL
O L
OC
O29
95 T
EMPL
ATE
FOR
STA
TE O
F AR
IZO
NA
REVISIONS
NO. DATE DESCRIPTION
SHEET LIST
SHEETNUMBER SHEET NAME
CURRENTREVISION
CURRENTREVISION
DATE
S1.00 GENERAL NOTES &ABBREVIATIONS
S2.00 TYPICAL DETAILS
S5.00 ROOF FRAMING PLAN
S3.00 TYPICAL DETAILS
S4.00 FOUNDATION PLAN
S6.00 FOUNDATION DETAILS
S7.00 ROOF FRAMING DETAILS
S8.00 ROOF FRAMING DETAILS,ISOMETRIC VIEW
A DETAILA/
S2
1'-6"
10'-0"
N.T.S.
FOR PIPES MORE THAN3'-0" BELOW THE BOTTOMOF THE FOOTING. TRENCHMAY BE BACKFILLED WITHCOMPACTED FILL PERSPECIFICATIONS. DO NOTTRENCH BELOW FOOTINGAFTER FOOTING HAS BEENPOURED.
NO PIPE ALLOWED TOPASS THROUGH THISPORTION OF FOOTING.
PLUMBING OR CONDUIT TO BEHELD AS HIGH AS POSSIBLE.
CONCRETE FILL SHALL BE SAME WIDTHAS FOOTING AND FULL WIDTH OF TRENCH.PLACE FILL BEFORE FOOTING IS PLACED.
NO EXCAVATIONBELOW THESE LINES.
1
2
2
1
COMPACT TO90% OPTIMUMDENSITY.
T.O.GRADE
BACKFILL PER SPECIFICATIONS
MIN
.
6"
MIN
.
4"9"
2" M
IN.
1'-6" MIN. 1'-6" MIN.
ØØ
12Ø
1
6
BENDS AND HOOKS #3 THRU #8
#9,#10 & #11
#14 & # 18
SPLICES
NOTE: LENGTH OF LAPFOR CLASS B SPLICESHALL BE 50Ø FORCONCRETE (60Ø FORMASONRY). CLASS BSPLICES SHALL BENOTED ON THE PLANS.
NOTE: USE THE LARGER BARDIAMETER (Ø) OF THE BARSIN THE SPLICE TO DETERMINESPLICE LENGTH.
CLASS A SPLICE
4Ø
5Ø
6Ø
4" MIN.
6Ø
Ø1
1/2"
MIN
.1
1/2Ø
Ø2'-0" MIN. LAP
50Ø FOR MASONRY40Ø FOR CONCRETE
TYP.
2x STUD TYP.
2x OR 3x BLOCKING, TYP.
DBL 2x END STUD, MIN. U.N.O.KING POST
2x TRIMMER
HOLDOWN ANCHOR PER SCHEDULE AND PLAN
6" (TYP.)14" AT HOLDOWN ANCHOR
"X"INDICATES EDGE NAILING-SEE SHEAR PANEL
SCHEDULE FOR NAIL SIZE AND SPACING.
2x TREATED SILL PLATE, TYP.
SILL ANCHOR BOLT PER SCHEDULE
S3
3
S3
1
S2
5
3/8"
MIN
., TY
P
2' -
0" M
IN. O
FFSE
T2'
- 0"
MIN
. OFF
SET
12" T
YP.
FN
ENEN
EN EN
DBL PL.
OFF
SET
2' -
0" M
IN.
*
*
EN EN
ENEN
EN EN
ENEN
EN EN
*
** - MINIMUM DIMENSION OF ANY SHEET = 2' - 0"
NOTES:1. FOR SHEAR WALL SCHEDULE, SEE
2. INDIVIDUAL PIECES OF WOOD STRUCTURAL PANEL SHALL BE NOT LESS THAN 2'-0" IN LEAST DIMENSION NOR 8 FT. IN AREA.
3. RE-TIGHTEN BOLTS BEFORE CLOSING.
4. FOR DOUBLE TOP PLATE SPLICE, SEE
PROVIDE FURRING OR BACKING OF THICKNESS AS REQUIRED TO MAINTAIN A COMMON WALL PLANE AT ALL WOOD STUD WALL SURFACES WHICH ARE ONLY PARTIALLY SHEATHED WITH WOOD STRUCTURAL PANEL COORDINATE AND ADJUST HEAD, JAMB AND SILL DETAILS AS REQUIRED FORPROPER OVERALL WALL THICKNESS.
"X" 3/8"
3/8"
(2) 2x PLATES OR PLATES TO BEAM
SPLICE STRAP PER PLAN
SPLICE
NOTE:SPLICE ONLY PERMITTED ATMID 1/3 OF SHEAR WALL.
w/ (10) 16d NAILS, MIN, U.N.O.
48" SPLICE
EQ EQ
STRAP PER PLAN
(2) 2x PLATES OR PLATES TO BEAM
LOCATE VERTICAL STUDS AT SPLICE
BUTT END OR ENDOF SILL PLATE
6"6"
3" MIN. WHEREDRYPACK OCCURS
TOP OF CONC.
2x NAILER, TYP.U.N.O.
BORE OR NOTCH
"W"
TYPICAL SILL PLATE
PLAN
MINIMUM SILL BOLT
A
C
B
SILL BOLT REQUIREMENTS
1. PROVIDE A MINIMUM SILL BOLT EMBEDMENT OF 7" BELOW FINISH FLOOR OR TOP OF CURB.
2. PROVIDE AN ADDITIONAL SILL BOLT 6 INCHES FROM EACH END OF EACH
3. WHERE SILL PLATES ARE BORED OR NOTCHED IN EXCESS OF 1/3 OF THE SILL PLATE WIDTH, PROVIDE ADDITIONAL SILL BOLTS 6 INCHES EACH SIDE OF BORE OR NOTCH.
4. SET ALL SILL BOLTS WITH A SETTING TEMPLATE BEFORE PLACING CONCRETE. STABBING OR PUSHING OF SILL BOLTS INTO WET CONCRETE IS EXPRESSLY PROHIBITED
5. PROVIDE A MINIMUM SILL BOLT PROJECTION ABOVE THE CONCRETE AS SHOWN ON DETAIL C.
6"
.
t
WIDTH = 1/8"
t/3
SLAB ON GRADE PER PLAN
CRACK CONTROL JOINT (CCJ)
CONSTRUCTION JOINT
0' - 8" 0' - 8"
tt
SLAB ON GRADE PER PLAN
LOAD TRANSFER DEVICEPER SPECIFICATION
NOTE: CUT CONTROL JOINT AS SOON AS CONCRETE CAN SUPPORT MACHINE AND LABORERS WITHOUT DAMAGING CONCRETE SURFACE. SEE FOUNDATION PLAN OF CONTROL JOINT LOCATIONS.
#5 VERT. MIN.TYP. U.O.N.
TYP. CORNER TYP. INTERIOR
DOUBLE LAYER REINFORCING
30 x DIA. (18" MIN.)
30 x DIA. (18" MIN.)
30 x
DIA
. (18
" MIN
.)
TYP.
6"
2x STUDREF. PLAN
HEADERREF. PLAN
USE (4) 16d TO POSTAT 4x6 TRIMMER &20d AT 12" O.C. AT REMAINDER
TRIMMER STUD(1) 2x MIN. (U.O.N.)WHERE INDICATED
1 STUD ADJACENTFOR EXTERIOR OPENING (U.O.N.) ON THE PLANS & INTERIOR OPENING
FOR MULTIPLE
2x BLOCKING AT MID HEIGHT
16d AT 12" O.C.TYP. (U.O.N.)
2x FIRESTOP
(4) 16dEACH
END
WALLHEIGHT
OPENINGWIDTH
KING POST(U.O.N)
8"
8"
10"
10"
10"
6'-0"
10'-0"
4'-0"
8'-0"
10'-0"
(1) 2x
(2) 2x
(1) 2x
(2) 2x
(3) 2x
SILL PLATE
0.145" DIAMETER AT 32" O.C.POWDER ACTUATEDFASTENER W/ (2) 7/8" WASHER W/ MIN. 1 1/2" EMBED AT 32" O.C.
SIMPSON DTC ROOF TRUSS CLIP ON BOTH SIDES
SIMPSON A35, TYP.
ROOF TRUSS, TYP.
2x6VERT. BLOCKINGAT 24" O.C. W/ (2) 16dEACH END, EACH SIDE
SILL PLATE
0.145" DIAMETER AT 32" O.C.POWDER ACTUATEDFASTENER W/ (2) 7/8" WASHER W/ MIN. 1 1/2" EMBED AT 32" O.C.
SIMPSON DTC ROOF TRUSS CLIP ON BOTH SIDES
ROOF TRUSSES, TYP.
WALL PARALLEL TO TRUSSES WALL PERPENDICULAR TO TRUSSES
1" C
LR
1" C
LR
SLAB ON GRADE PER PLAN
PREPARED SUBGRADE PER GEOTECHNICAL ENGINEER
4" GRANULAR FILL
WWF OR REINF. (CENTERED IN SLAB) PER PLAN
VAPOR BARRIER PER PLAN
VERT. STUDS
2x D.F. SILL PLATE (P.T.)
0.146" DIA. x 2 7/8" REDHEAD PIN AND WASHER (ICC ESR-2690) @ 32" O.C.
1 1/2"#4 CONT. NOSING BAR
't'
MAX8"
NOTE: SEE DETAIL ABOVE FOR INFORMATION NOT SHOWN.
't'
2 x 't'
TYPICAL SLAB ON GRADE
DEPRESSED SLAB ON GRADE
EQ.
EDGENAILING
EDGE OF ROOFAND/OR EXTERIORWALL BELOW
BUTT WOOD STRUCTURALPANEL SHEETS ALONG
OF SUPPORTS
EDGE NAILINGFOR SIZE ANDSPACING- SEENOTES
2x4 FLAT BLOCKING WITH Z-SHAPED SHEET METAL CLIPS WITH 4-NAILS EACH END
BUTT WOOD STRUCTURAL PANELSHEETS ALONG
OF BLOCKING
RAFTERS
BLOCKING
FIELD NAILINGTYPICAL-SEENOTES FORSPACING
E.N.
ROOF SHEATHING NOTES:
1. WOOD STRUCTURAL PANEL SHEATHING: PER ROOF PLAN
-THICKNESS: 3/4 INCH
2. NAILS FOR WOOD STRUCTURAL PANEL SHEATHING: PER PLAN
3. PROVIDE WOOD STRUCTURAL PANEL SHEETS NOT LESS THAN 2'-0" IN LEAST DIMENSION NOR LESS THAN 8'-0" SQ. FEET IN AREA. USE FULL SHEETS WHEREVER POSSIBLE.
4. PLACE WOOD STRUCTURAL PANEL SHEET WITH FACE PLIES PERPENDICULAR TO JOISTS.
5. COORDINATE JOIST LAYOUT WITH 4'-0" MODULE AS RELATED TO 48/24 APA RATED SHEATHING EXPOSURE 1.
6. MACHINE APPLIED NAILING: THE CONTRACTOR WILL DEMONSTRATE SATISFACTORY INSTALLATION ON THE JOB AND OBTAIN THE ACCEPTANCE OF ARCHITECT AND/OR STRUCTURAL ENGINEER BEFORE THE USE OF MACHINE APPLIED NAILS CAN BE APPROVED. APPROVAL IS SUBJECT TO CONTINUED SATISFACTORY PERFORMANCE. REMOVE ALL "SHINERS".
7. PREDRILL HOLES FOR NAILING WHEN WOOD TENDS TO SPLIT.
DETAIL
SECTION
A
A
B
BSLAB ON GRADEPER PLAN
SIMPSON CPS6 ARCHITECTURAL POST BASE w/ (4) 10d NAILS AND (1) 5/8" DIA. x 1'-4"
F1554-36 THREAEDED ROD. DRILL AND EPOXY w/ SIMPSON SET EPOXY. EMBED = 5"
L3x3x1/4' 0'-6" EACH SIDEw/ (2) 3/8" DIA. x 3" LAG SCREWS
TO COLUMN & TO BLOCKING. SHORT SLOT HOLES ON VERT. LEG IN VERT.
DIRECTION
SIMPSON A34 AT 24" O.C.TO BLOCKING
GIRDER TRUSS
2x BLOCKING CONT. OVER WINDOW WALL
CLR3"
(2) #4 IN EACH DIRECTION
8"
1' - 0"
10"
HSS4x2 (LLH) HORIZ. TUBE PER ARCH.
1 1/2"
3"1 1/2"
1"
1/2"
HSS4x2 (LLH) VERT. TUBE PER ARCH. w/ 1/2" DIA. x 4" LAG SCREWS @ 12" O.C.
1/8TYP.
2" DIA. ACCESS HOLES FOR SOCKET ACCESS, TYP.
6x6 D.F. POST
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
NOT FOR CONSTRUCTIO
N
S2.00
17XXX
[Project Status]
[Date]
TYPICAL DETAILS
EL P
OLL
O L
OC
O29
95 T
EMPL
ATE
FOR
STA
TE O
F AR
IZO
NA
N.T.S.1
TYPICAL PIPE & TRENCH DETAIL
N.T.S.2
TYPICAL REINFORCING BAR DETAILS 1/2" = 1'-0"
3TYPICAL SHEAR WALL CONSTRUCTION
3/4" = 1'-0"4
TOP PLATE SPLICE PLAN
1" = 1'-0"5
DOUBLE TOP PLATE SPLICE
N.T.S.13
SILL PLATE DETAILS 3/4" = 1'-0"
11TYP DTL - SLAB ON GRADE JOINT
3/4" = 1'-0"6
TYP. REINF. @ INTERSECTION OF CONC. BEAMS, WALLS & FTG.
3/4" = 1'-0"10
TYP. HEADER DETAILS (U.O.N.) 3/4" = 1'-0"
12TYPICAL NON-BEARING WALL DETAIL
3/4" = 1'-0"7
TYP DTL - SLAB ON GRADE
N.T.S.9
STRUCTURAL PANEL ROOF SHEATHING 3/4" = 1'-0"
8PARTITION SUPPORT
REVISIONS
NO. DATE DESCRIPTION
FASTENING SCHEDULE PER TABLE ESR-1539CONNECTION FASTENING LOCATION
a,m
1.) JOIST TO SILL OR GIRDER
2.) BRIDGING TO JOIST
3.) 1x6 SUBFLOOR OR LESS TO EACH JOIST
4.) WIDER THAN 1x6 SUBFLOOR OR LESS TO EACH JOIST
5.) 2" SUBFLOOR TO JOIST OR GRIDER
7.) TOP PLATE TO STUD
9.) DOUBLE STUD
12.) RIM JOIST TO TOP PLATE
13.) TOP PLATES, LAPS AND INTERSECTIONS
14.) CONTINUOUS HEADER, TWO PIECES
15.) CEILING JOIST TO PLATE
16.) CONTINUOUS HEADER TO STUD
17.) CEILING JOIST, LAPS OVER PARTITIONS
18.) CEILING JOIST PARALLEL TO RAFTERS
19.) RAFTER TO PLATE
20.) 1" DIAGONAL BRACE TO EACH STUD AND PLATE
21.) 1x8 SHEATHING TO EACH BEARING
22.) WIDER THAN 1x8 SHEATHING TO EACH BEARING
25.) 2" PLANKS
26.) COLLAR TIE TO HIP
29.) JOIST TO BAND JOIST
30.) LEDGER STRIP 5 -3" X 0.131" NAILS
4 - 3" X 0.131" NAILS
4 - 3" X 0.131" NAILS
3" X 0.131" NAILS
3 - 3" X 0.131"
2 - 3" X 0.131" FACE NAIL
2 - 3" X 0.131" NAILS
3 - 3" 0.131 NAILS
4 - 3" X 0.131" NAILS
4 - 3" X 0.131" NAILS
4 - 3" X 0.131"
4 - 3" X 0.131" NAILS
3" X 0.131"
3 - 3" X 0.131 NAILS
3" X 0.131 NAILS AT 6" O.C.
3" X 0.131 NAILS AT 16" O.C.
4 - 3" X 0.162" NAILS
3-1/2" X 0.162" NAILS
2-1/2" X 0.131" NAILS
2-1/2" X 0.131" NAILS
2 - 3" X 0.131" NAILS
3 - 3" X 0.131" NAILS TOE NAIL
TOE NAIL EACH END
FACE NAIL
FACE NAIL
BLIND & FACE NAIL
END NAIL
FACE NAIL
TOE NAIL
FACE NAIL
8" O.C. ALONG EDGE
TOE NAIL
TOE NAIL
FACE NAIL
FACE NAIL
TOE NAIL
FACE NAIL
FACE NAIL
AT EACH BEARING
FACE NAIL
FACE NAIL FACE NAIL
6.) SOLE PLATE TO JOIST OR BLOCKING
SOLE PLATE TO JOIST OR BLOCKING AT BRACED WALL PANEL
8.) STUD TO SOLE PLATE
10.) DOUBLE TOP PLATES DOUBLE TOP PLATES
11.) BLOCKING BETWEEN JOIST OR RAFTERS TO TOP PLATE
23.) BUILT UP CORNER STUDS
24.) BUILT UP GIRDERS BEAMS
27.) JACK RAFTER TO HIP
28.) ROOF RAFTER TO 2X RIDGE BEAM
3" X 0.131 NAILS AT 12" O.C.
4 - 3" X 0.131 NAILS AT 12" O.C.
4 - 3" X 0.131" NAILS
4 - 3" X 0.131" NAILS
3" X 0.131 NAILS AT 12" O.C.12-3" X 0.131" C
3 - 3" X 0.131" NAILS
3" X 0.131 NAILS
3" X 0.131 NAILS AT 24" O.C.
3" X 0.131 NAILS
5 - 3" X 0.131 NAILS
3" X 0.131" NAILS
5 -3" X 0.131 NAILS
4 - 3" X 0.131 NAILS
TYPICAL FACE NAIL BRACED WALL PANELS
TOE NAILEND NAIL
TYPICAL FACE NAIL LAP SPLICE
TOE NAIL
24" O.C.16" O.C.
FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPOSITE SIDES
FACE NAIL AT ENDSAND AT EACH SPLICE
TOE NAIL
FACE NAIL
TOE NAIL
FACE NAIL
A. NAILS SHOWN ARE POWER DRIVEN.B. NAILS SPACED AT 6 INCHES ON CENTER AT EDGES, 12 INCHES AT INTERMEDIATE SUPPORTS EXCEPT 6 INCHES AT SUPPORTS WHERE SPANS ARE 48 INCHES OR MORE. * FOR NAILING OF WOOD STRUCTURAL PANEL AND PARTICLEBOARD DIAPHRAGMS AND SHEAR WALLS, REFER TO SECTION 2305. * NAILS FOR WALL SHEATHING ARE PERMITTED TO BE COMMON, BOX OR CASING.C. COMMON OR DEFORMED SHANK (6d - 2" X 0.113"; 8d - 2 1/2" X 0.131"; 10d - 3" X 0.148")D. COMMON OR DEFORMED SHANK (6d - 2" X 0.113"; 8d - 2 1/2" X 0.131"; 10d - 3" X 0.148")E. DEFORMED SHANK (6d - 2" X 0.113"; 8d - 2 1/2" X 0.131"; 10d - 3 X 0.148")F. CORROSION-RESISTANT SIDING (6d - 1-7/8" X 0.106"; 8d - 2 3/8" X 0.128") OR CASING (6d - 2" X 0.099": 8d - 2 1/2" X 0.113") NAIL.G. FASTENERS SPACED 3 INCHES ON CENTER AT EXTERIOR EDGES AND 6 INCHES ON CENTER AT EXTERIOR EDGES AND 6 INCHES ON CENTER AT INTERMEDIATE SUPPORTS, WHEN USED AS STRUCTURAL SHEATHING. SPACING SHALL BE 6 INCHES ON CENTER ON THE EDGES AND 12 INCHES ON CENTER INTERMEDIATE SUPPORTS FOR NON-STRUCTURAL APPLICATIONS.H. CORROSION- RESISTANT ROOFING NAILS WITH 7/16 INCH DIAMETER HEAD AND 1 1/2 INCH LENGTH FOR 1/2 INCH SHEATHING AND 1 3/4 INCH LENGTH FOR 24/32 INCH SHEATHING.I. CORROSION - RESISTANT STAPLES WITH A NORMAL 7/16 INCH CROWN AND 1 1/8" LENGTH FOR 1/2 SHEATHING AND 1 1/2 INCH LENGTH FOR 25.32 INCH SHEATHING. PANEL SUPPORTS AT 16 INCHES (20 INCHES IF STRENGTH AXIS IN THE LONG DIRECTION OF THE PANEL, UNLESS OTHERWISE MARKED). J. CASING (1 1/2" X 0.080") OR FINISH ( 1 1/2" X 0.072") NAILS SPACED 6 INCHES ON PANEL EDGES, 12 INCHES AT INTERMEDIATE SUPPORTS.K. PANEL SUPPORTS AT 24 INCHES. CASING OR FINISH NAILS SPACED 6 INCHES ON PANEL EDGES, 12 INCHES AT INTERMEDIATE SUPPORTS.L. FOR ROOF SHEATHING APPLICATIONS, 8d NAILS (2 1/2" X 0.113") ARE THE MINIMUM REQUIRED FOR WOOD STRUCTURAL PANELS.M. STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7/16 INCH.N. FOR ROOF SHEATHING APPLICATIONS, FASTENERS SPACED 4 INCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE SUPPORTS.O. FASTENING SPACED 4 INCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE SUPPORTS FOR SUB-FLOOR AND WALL SHEATHING AND 3 INCHES ON CENTER AT EDGES, 6 INCHES AT INTERMEDIATE SUPPORTS FOR ROOF SHEATHING.P. FASTENERS SPACED 4 INCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE SUPPORTS.
SW SHEATHING EDGE FIELD PLATE / ANCHOR BOLT HOLDOWN REMARKS
2
3
4
1/2" CDX PLWD (32/16), PS1 RATING (EA. SIDE)
1/2" CDX PLWD (32/16), PS1 RATING
1/2" CDX PLWD (32/16), PS1 RATING (EA. SIDE)
1/2" CDX PLWD (32/16), PS1 RATING
0.135"x2" @ 2" O.C.
0.135"x2" @ 4 O.C.
0.135"x2" @ 4" O.C.
0.135"x2" @ 6" O.C.
0.135"x2" @ 12" O.C.
0.135"x2" @ 12" O.C.
0.135"x2" @ 12" O.C.
0.135"x2" @ 12" O.C.
5/8" DIA. A307 (10") @ 12" O.C. W/ WASHER
5/8" DIA. A307 (10") @ 36" O.C. W/ WASHER
5/8" DIA. A307 (10") @ 16" O.C. W/ WASHER
5/8" DIA. A307 (10")@ 48" O.C. W/ WASHER
HDQ8-SDS3
HDU2-SDS2.5
HDU8-SDS2.5
PLYWOOD ON EACH FACE OF STUDS
PLYWOOD ON EXTERIOR FACE OF STUDS
PLYWOOD ON EACH FACE OF STUDS
1. OSB OF COMPARABLE THICKNESS MAY BE USED IN LIEU OF PLYWOOD WHEN APPROVED IN WRITING BY THE PROJECT ENGINEER AND THE LOCAL JURISDICTION.
2. EDGE NAIL WALL PLYWOOD TO STUDS OR POSTS WITH HOLD-DOWNS.
3. ALL PLYWOOD NAILS SHALL BE POWER DRIVEN.
4. EXTERIOR WALLS NOT DESIGNATED AS SHEARWALLS IN THE WALL FRAMING PLAN SHALL MEET REQUIREMENTS INDICATED FOR NON-SHEARWALL WALLS IN THE SCHEDULE ABOVE.
5. SHEARWALL LENGTHS WHERE NOTED ARE MIMIMUM. DO NOT LOCATED HOLDOWN FROM THESE DIMENSIONS. SEE ARCH DWGS FOR ACTUAL WALL LENGTHS.
6. HD REFERS TO SIMPSON STRONGTIE CO. HOLDOWNS. INSTALL PER HOLDOWN SCHEDULE 2/S3. POST WIDTH SHALL MATCH STUD WALL WIDTH. SEE FOUNDATION PLAN FOR OTHER REQ'S.
7. WHERE PANELS ARE APPLIED TO BOTH FACES OF A WALL AND NAIL SPACING IS LESSTHAN 4" O.C. ON EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO WALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3x OR THICKER AND NAILS ON EACH SIDE SHALL BE STAGGERED.
8. THE ANCHOR BOLT LENGTH LISTED IN SCHEDULE ABOVE (EXAMPLE : 10") SHALL BE THE EMBEDMENT LENGTH INTO CONCRETE AND NOT THE OVERALL LENGTH OF THE ANCHOR.
4 REQUIREMENTS FOR EXTERIOR WOOD SHEATHING AT NON-SHEARWALL WALLS
1
PLYWOOD ON EXTERIOR FACE OF STUDS
SIMPSONHOLDOWN
MACHINE BOLT DIA
A B*(MIN.)
SIMPSONANCHOR BOLT
HDU8
HDU2
N/A
N/A
1-3/8"
1-5/16"
12"
10"
PAB7-16
PAB5-16
SINGLE POUR
TOP OF FDN. POURWHERE OCCURS -MAY ALSO BE TOP OF SLAB
3" MIN. CLR. TOBOT. OF FTG.
2x TRIMMER
END POST PER PLAN W/SHEAR PANEL E.N.FULL HEIGHT
HOLDOWN PER PLAN W/SDS-2.5 SCREWS PER
MANUF. SPECIFICATIONS
PRESSURE TREATED SILL PER PLAN
TOP OF SLAB
SIMPSON "PAB" CIP ANCHOR BOLTSINSTALLED PER MANUFACTURER
RECOMMENDATIONS
* INCREASE FOOTING DEPTH AS REQ'D FORANCHOR BOLTEMBEDMENT
** ANCHOR BOLT LENGTH TO EXTEND 6"BEYOND CONST. JOINT
A
.B
2 x 'B', MIN
.
MINIMUM CLEAR COVER
B
6" MIN.
HDQ8 N/A 1- 1/4" 10" PAB7-16
BRIDGING PER TRUSS SUPPLIER
WOOD TRUSS BY TRUSS SUPPLIER, TYP.
NAILS AS REQUIRED PER TRUSS SUPPLIER
1" MAX.
DRILL 1"Ø HOLEBEFORE CUTTINGNOTCH IN WOOD
WOOD STUD
NOTE:
THIS DETAIL SHALL APPLY FOR ELECTRICAL CONDUITS, PLUMBING AND FOR ANY OTHER USES WHICH REQUIRE NOTCHING.
14" MAX.
14" M
AX.
MINOR OPENING
MECHANICAL DUCT OPENINGS
NOTES :
1. NO OPENINGS OVER ONE STUD WIDTH TO OCCUR IN WOOD STRUCTURAL PANEL SHEAR PANELS UNLESS DETAILED ON STRUCTURAL ELEVATIONS. OPENINGS IN WOOD STRUCTURAL PANEL SHALL BE CUT WITH SABER SAW.
2. SEE , THERE SHALL BE
NO OPENINGS/PENETRATIONS AT
SHEAR PANEL. GENERAL CONTRACTOR TO COORDINATE, TYP. U.N.O. ON PLAN
DRILL 1"ØAT CORNERSBEFORECUTTINGOPENINGS
METAL TIE STRAP ATCORNER 2x OR 3x
2x OR 3x BLK'G.TYP.
EDGE NAILAROUNDOPENING
A
B
S3
1
TIE STRAPABOVE SHT'G. TYP.AT CORNERS.
JOIST HANGEREA. END
2x4 FLAT BLK'G. WITH Z-SHAPED SHEET METAL CLIPS WITH 4-NAILS EA. END
PROVIDE FILLER BLOCK
EA. END
JOIST HANGERS EA. END
2x6 MIN.
DBL.
EDGE NAIL SHT'G. TOALL MEMBERS FRM'G.
EDGE OF OPN'G.
DBL. JOIST
2x6 MIN.
NOTE: FOR SMALLOPNG'S. SEE DETAIL S3
6
48" MAX
40" M
AX
GYP. BOARD OR PLYWOOD
SHEATHING - SEE WALL SCHEDULE FOR NAILING
SIMPSON HOLDOWN REF. 2/S3
SSTB ANCHOR BOLT TYP.REF 2/S3
KING STUD POST(2) 2x6
1 TRIMMER STUD REF. PLAN FOR LOCS.
FACE OF ROUGH OPENING
GYP. BOARD OR PLYWOOD
PLYWOOD SHEATHING - SEE WALL SCHEDULE FOR TYPEAND NAILING
SSTB ANCHOR BOLTTYP., REF 2/S3
SIMPSON HOLDOWN REF. 2/S3
WALL PLYWOOD E.N.
KING STUD POST (4) 2X6
WALL PLYWOOD E.N.
1X NAILER FOR GYP. BOARD
GYP. BOARD OR PLYWOOD
SHEATHING - SEE WALL SCHEDULEFOR NAILING TYPE
SIMPSON HOLDOWN REF. 3/S3
SSTB ANCHOR BOLT TYP.REF 3/S3
KING STUD POST(3) 2x6
1 TRIMMER STUD REF. PLAN FOR LOCS.
FACE OF ROUGH OPENING
GYP. BOARD OR PLYWOOD
SHEATHING - SEE WALL SCHEDULE FOR NAILING TYPE
SIMPSON HOLDOWN REF. 3/S3
SSTB ANCHOR BOLT TYP.REF 3/S3
KING STUD POST(2) 2x6
GYP. BOARD OR PLYWOOD
PLYWOOD SHEATHING - SEE WALL SCHEDULE FOR TYPEAND NAILING
SSTB ANCHOR BOLT TYP.
REF 2/S3 SIMPSON HOLDOWN REF. 3/S3.
WALL PLYWOOD E.N.
KING STUD POST (2) 2X6
WALL PLYWOOD E.N.
1X NAILER FOR GYP. BOARD
GYP. BOARD OR PLYWOOD
SHEATHING - SEE WALL SCHEDULEFOR NAILING TYPE
SIMPSON HOLDOWN REF. 2/S3
SSTB ANCHOR BOLT TYP.REF: 2/S3
KING STUD POST (2) 2x6
WALL PLYWOOD E.N.
KING STUD POST (1) 4x6 & (2) 2x6
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
NOT FOR CONSTRUCTIO
N
S3.00
17XXX
[Project Status]
[Date]
TYPICAL DETAILS
EL P
OLL
O L
OC
O29
95 T
EMPL
ATE
FOR
STA
TE O
F AR
IZO
NA
N.T.S.3
HOLDOWN DETAILS
6" = 1'-0"1
SHEATHING AND SHEAR WALL SCHEDULE 3/4" = 1'-0"
2HOLDOWN SCHEDULE
3/4" = 1'-0"4
TRUSS BRIDGING 3" = 1'-0"
5NOTCH IN STUD
3/4" = 1'-0"6
OPENING IN PLYWOOD SHEATHING
3/4" = 1'-0"7
ROOF OPENING AT JOIST
3A 3B 3C
3D 3E
3F
REVISIONS
NO. DATE DESCRIPTION
FOUNDATION PLAN NOTES 1. SLAB ON GRADE SHALL BE 4" THICK MINIMUM w/ #3 REBARS EACH WAY @
18" O.C. AT MIDSLAB ON TOP OF PROPERLY PREPARED SUBGRADE PER SOIL REPORT.
2. FOOTING SIZES PER PLAN.3. ALL ANCHOR BOLTS AND HOLD DOWN ANCHORS SHALL BE TIED IN PLACE
PRIOR TO FOUNDATION INSPECTION.
4. ALL SILL PLATES TO BE PRESSURE TREATED DOUG.FIR.
5. FOR DIMENSIONS AND DETAILS NOT SHOWN, SEE ARCHITECTURAL DRAWINGS.
6. SEE ARCHITECTURAL DRAWINGS, FOR SLAB SLOPES AND FLOOR DRAINS.
7. INDICATES SHEAR WALL PER SHEAR WALL PER SCHEDULE ON SHEET S3.
8. PRIOR TO CONTRACTOR REQUESTING A BUILDING DEPT. FOUNDATION INSPECTION, THE GEOTECHNICAL ENGINEER SHALL ADVISE THE BUILDING OFFICIAL IN WRITING THAT:
A. THE BUILDING PAD WAS PREPARED IN ACCORDANCE WITH SOILS REPORT.
B. THE UTILITY TRENCHES HAVE BEEN PROPERLY BACKFILLED AND COMPACTED.
C. THE FOUNDATION EXCAVATIONS, SOIL EXPANSION CHARACTERISTICS & BEARING CAPACITY CONFORM TO THE SOILS REPORT.
9. INDICATES SHEAR WALLS AND SHEAR TRANSFERS FOR WALLS BELOW ROOF FRAMING. SEE SHEET S3 FOR SHEARWALL SCHEDULE.
10. INDICATES INTERIOR METAL STEEL STUD WALL. REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION.
11. GRID LINES INDICATE OUTSIDE FACE OF STRUCTURAL STUD WALL.
12. INDICATES FOUNDATION KEYNOTE.
1 2 3 4 5
D.1
D
C
B
A
75' - 1"
27' - 6 1/2" 10' - 8 3/4" 11' - 4 3/4" 25' - 5"
15' - 0" 7' - 9"
3
S6.00
38' - 3 1/4" 36' - 9 3/4"
PER
AR
CH
.R
EF. A
RC
H.
PER ARCH.
1
S6.00
S3.00
3F
S3.00
3E
S3.00
3A
S3.00
3A
37'-0"
C.J
.
C.J
.
C.J
.
C.J
.
C.J
.
1
S6.00
3
S6.00
3
S6.00
1
S6.00
C.J
.
C.J.
C.J.
C.J.
1' -
4"
425"-0"
425'-0"
15' - 0"
17' - 9"
S3.00
3C
PER ARCH.
S3.00
3D
S3.00
3E
S3.00
3E
4
S6.00
4
S6.00
8
S6.00
3
3
6x6 WOOD POST
6x6 WOOD POST
1
4' - 9 1/2"
1' -
1 1/
8"
3' - 9 7/8" 4' - 0"
44' -
6"
8"
19' -
7"
3' -
10"
3' -
4"2'
- 8"
B.2B.2
6 3/4" 9' - 9"
5"
37' -
5 1
/2"
7' -
9"21
' - 6
"8'
- 2
1/2"
1' -
8 1/
2"
10' - 8 3/4"
5' - 0" 17' - 6" 5' - 0 1/2"
15'-0"
27'
-6"
14'- 9"
5' -
11"
C.J.
36'
-0"
5
S6.00
215'-0"
27'
- 6"
36' - 9 3/4"
5
5
6
5
4
4
2
2
2
S3.00
3F
4
SIM.
6
4
S6.00
SIM.
S3.00
3C
S3.00
3E
5
4
4
1
1' - 9 1/2"
6 6
1' -
4"
4
4
11' - 4 3/4"
1' - 4"
100' - 0"100' - 0"
6
6
5
S6.00
SIM
5
S6.00
SIM 5
S6.00
SIM
S3.00
3E
1' -
4 1/
2"
2
8
8
88
8
8
8
8
2' -
6"
2' -
6"
1' - 4"
1' - 4"
1' - 10"
1' -
10"
1' - 4"
1' -
10"
1' - 4"
1' - 10"
1' -
10"
1' -
4"
1' - 4"
1' -
4"
1' -
4"
1' -
4"
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
NOT FOR CONSTRUCTIO
N
S4.00
17XXX
[Project Status]
[Date]
FOUNDATIONPLAN
EL P
OLL
O L
OC
O29
95 T
EMPL
ATE
FOR
STA
TE O
F AR
IZO
NA
1/4" = 1'-0"1
FOUNDATION PLAN
FOUNDATION KEYNOTE
1 8" DEEP x 12" WIDE THICKENED SLAB FOR QUEUE PARTITION COREDRILLING
2 2'-6" x 2'-0" DEEP FOOTING WITH #6 REINFORCING @ 12" O.C. AT TOP AND BOTTOM OF FOOTING WITH #3TIES @ 48" O.C.
3 1'-0" x 1'-0" x 0'-8" DEEP THICKENED SLAB PER DETAIL 8/S2.
4 (2) 2X6 KING STUD WITH E.N.
5 (3) 2X6 KING STUD WITH E.N.
6 4X KING STUD WITH (2)2X TRIMMER WITH E.N.
8 PROVIDE MINIMUM CONCRETE EDGE DISTANCE FOR HOLDOWN ANCHOR BOLT PER DETAIL 2 ON S3.
REVISIONS
NO. DATE DESCRIPTION
TRUSS DESIGN CRITERIA
NOTE:IN ADDITION TO LOADS SHOWN ABOVE, TRUSS SUPPLIER TO DESIGN TRUSSES FOR CONCENTRATED LOADS FROM MECHANICAL UNITS AS SHOWN ON ROOF PLANS. SEE ROOF PLAN FOR PRELIMINARY WEIGHT & LOCATION. CONFIRM LOADS WITH MECHANICAL SUPPLIER PRIOR TO DESIGN OF TRUSS.
BOTTOM CHORD
DEAD LOAD(SERVICE)
10 PSF
TOP CHORD
DEAD LOAD(SERVICE)
10 PSF
TOP CHORD
LIVE LOAD(SERVICE)
20 PSF
WINDWARD PARAPET LOAD
LEEWARD PARAPET LOAD
26.5 PSF WINDWARD14.7 PSF LEEWARD
26.5 PSF WINDWARD14.7 PSF LEEWARD
NOTE: PARAPET (SERVICE) WIND PRESSURES FROM ASCE 7-10 FIGURE 30.9-1, 30.4-1 & 30.4-2A
TOP CHORD
NET WIND UPLIFT (SERVICE)
17.1 PSF (CORNER & EDGE ZONE) / 14.0 PSF (FIELD)
ROOF FRAMING PLAN NOTES
1. ALL ROOF SHEATHING SHALL BE 3/4" THICK (48/24) CDX, TONGUE AND GROOVE w/ BN/EN 10d @ 6" O.C. & FN 10d AT 12" O.C. (U.N.O.)
2. INDICATES FRAMING DIRECTION.3. ALL STRUCTURAL BEARING WOOD WALLS SHALL BE 2x6 VERTICAL STUDS @ 16" O.C. (U.N.O.)4. MINIMUM HEADERS, U.N.O. SHALL BE:
A. 6X6 - UP TO 4'-0" OPENING SPANB. 6X8 - UP TO 6'-0" OPENING SPANC. 6X10 - UP TO 8'-0" OPENING SPAN
5. INDICATES BLOCKED DIAPHRAGM. REFER TO DETAIL 7 ON S7 FOR MORE INFORMATION.
6. FOR ROOF SLOPES & OPENINGS, REFER TO ARCHITECTURAL ROOF PLAN.7. (10) 16d NAILS EACH SIDE OF TOP PLATE SPLICES (TYPICAL, U.N.O.). SEE DETAIL 5 ON S2.8. (F) - INDICATES FLUSH BEAMS.9. BOUNDARY NAILING IS REQUIRED AT ALL DRAG STRUTS & EDGE NAILING IS
REQUIRED AT ALL SHEARWALLS, TYP. 10. INDICATES SHEAR WALL PER SHEAR WALL
SCHEDULE ON SHEET S3.11. SHEARWALLS #1, #2 & #3 ARE REQUIRED TO BE BLOCKED.12. ALL NAILS ARE COMMON, U.N.O.13. (1) 2x IS REQUIRED MINIMUM UNDER BEAMS AND HEADERS, U.N.O.14. MST & CS SIMPSON STRAPS SHALL BE LOCATED ON TOP OF DOUBLE TOP PLATES.15. ENGINEERED WOOD TRUSSES:
A. EACH TRUSS SHALL BE LEGIBLY BRANDED (MARKED) OR OTHERWISE PERMANENTLY AFFIXED WITH THE FOLLOWINGINFORMATION LOCATED WITHIN TWO FEET OF THE CENTER SPAN ON THE FACE OF THE BOTTOM CHORD:
1.) NAME OF TRUSS MANUFACTURING COMPANY2.) DESIGN LOAD AS SHOWN ON CRITERIA BELOW.3.) SPACING OF TRUSS4.) DESIGNED SPAN ON THE FACE OF THE BOTTOM CHORD.
B. BOTTOM CHORD BRACING IS REQUIRED AT 10'-0" O.C. MAXIMUM.C. TRUSS DRAWINGS MUST BE APPROVED WITHIN FIFTY (50) DAYS OF
PERMIT ISSUANCE.D. SUBMIT APPROVED SHOP DRAWINGS & CALCULATIONS TO CITY FOR
PLAN CHECK & APPROVAL.E. APPROVED TRUSS DRAWINGS MUST BE ON JOB SITE FOR INSPECTION PURPOSES.
16. INDICATES ROOF PLAN KEYNOTE.
1 2 3 4 5
D.1
D.1
D
C
BB
A
4
S8.00
3
S8.00
2X8 BLOCKING @ 32" O.C. IN FIRST TWO BAYS,
1
S8.00
6
S8.00
5
S8.00
2
S8.00
DIAPHRAGM
6' - 0" BLOCKED
DIAPHRAGM
3 BAYS BLOCKED
3
S8.00
SIM
2X6 BLOCKING @ 16" O.C. IN FIRST BAY, MATCH STUD
SPACING IN WALL FRAMING
2X6 BLOCKING @ 16" O.C. IN FIRST BAY, MATCH STUD SPACING IN WALL
1
S8.00
SIM
1
S7.00
1
S7.00
1
S7.00
6
S7.00
9
S7.00
1
S7.00 5
S7.00
2
S7.00
5
S7.00
2
S7.00
4
S7.00
R1
4
S7.00
6
S7.00
10
S7.00
8
S7.00
2x8 BLOCKING @ 32" O.C. IN FIRST TWO BAYS,
425"-0"
425'-0"
5.25x16 PSL
5.25x16 PSL
6x8 (LLV)
6x8 (LLV)
4x6
(LLH
)
5.2
5x1
4 P
SL
CANOPYBY OTHERS
AT LDGRSPLICE TYP.
PROVIDE 6x6 BACKING ATTRELLIS CONN., TYP.
CANOPYBY OTHERS
AWNING, BEAM& CONNECTIONSBY OTHERS
(16) 16d EACH SIDEOF TOP PLATE SPLICETYP. AT THIS LINE
2x4 MIN. BLKG.AROUND UNITW/ SIMPSON A34EACH END, TYP.
AT LDGRSPLICE TYP.
CANOPYBY OTHERS
T.O. TRUSS EL. = 15'- 10 1/2"
T.O. TRUSS EL. = 16'- 8"T.O. TRUSS EL. = 16'- 7 3/4"
T.O. TRUSS EL. = 15'- 9"
GIR
DER
TR
USS
DES
FO
R 4
500#
AXI
AL
GIR
DER
TR
USS
DES
IGN
ED F
OR
345
0# A
XIAL
FO
RC
E
4x6
(LLH
)
27' - 6 1/2" 10' - 8 3/4" 11' - 4 3/4" 25' - 5"
1' -
8 1/
2"37
' - 5
1/2
"5'
- 4"
8"
ROOF DRAINS PER PLUMBING DRAWINGS. (TYPICAL)
R1
R3
R7
R6R3
R3
R5
R3
2' - 10"2' - 5" 2' - 8" 1' - 6" 2' - 8"
1' - 2" 2' - 8" 2' - 8" 2' - 8" 10 1/2"2' - 8" 2' - 8" 2' - 8" 2' - 8" 2' - 8" 1' - 6" 2' - 8"
2' - 8" 2' - 8" 2' - 8" 2' - 8" 2' - 8" 1' - 0" 2' - 8" 1' - 8" 2' - 5" 1' - 8"
B.2B.2
R1
RT- 12,400#
MAU- 11,412#
RT- 22,400#
KF- 2352#
KF- 1352#
KF- 396#
R8
R8
R8
R8R8
ROOF ACCESS OPENING
215
'-0"
27'
-6"
27'
- 6"
14'- 9" 1
7' - 9"
15'-0"
15' - 0"
37'
-0"
36'
-0"
EF- 150#
R8
44' -
6"
8"
6' -
4 1/
2"4' -
8"
2x8
MIN
. @ 2
4" O
.C.
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
NOT FOR CONSTRUCTIO
N
S5.00
17XXX
[Project Status]
[Date]
ROOF FRAMINGPLAN
EL P
OLL
O L
OC
O29
95 T
EMPL
ATE
FOR
STA
TE O
F AR
IZO
NA
1/4" = 1'-0"1
ROOF FRAMING PLAN
STRAP/ CONNECTOR KEYNOTES
R1 MSTC28 (H)
R3 CS14 (H) X 7'-0" WITH (15) 8D TO TOP PLATE OR LEDGER & 8D AT 6" O.C. TO BLK
R5 HTS24 (H) LEDGER TO TRUSS
R6 LTP4 @ 6" O.C. GIRDER TO TOP PLATE
R7 CMST12 (H) X 7'-0" WITH (37) 16D TO TOP PLATE & GIRDER
R8 CMSTC16 (H) X 6'-0" WITH (42) 8D TO TOP PLATE
REVISIONS
NO. DATE DESCRIPTION
FIRST FLOOR100' - 0"
A
DETAIL "B"
DETAIL "B"
2x6 AT 16" O.C.
CONTINUOUS SHEAR WALLREF. PLAN
2x PRE-TREATED SILL PLATEW/ 5/8" DIA. HEAVY HEX BOLT AT 48" O.C. MAX. (U.O.N.) REF. 1/S3 AT SHEARWALLS
#5 CONT. SLAB REF. PLAN
0.135x2 AT 12" O.C. OR AS REQUIRED PER
SHEAR WALL (REF. PLAN)
EXTERIORSHEATHING
EXTERIORSHEATHING
EDGE NAILING
FACE OF STUDS (TYP.)
.
3" C
LR.
1' - 4"
2' -
0"
#6 REINF. BARS @ 12" O.C. T&Bw/ #3 STIRRUPS AT 48" O.C.
CLR2"
CLR2"
FIRST FLOOR100' - 0"
5
(2) #6 REINF. BARS T&Bw/ #3 STIRRUPS AT 48" O.C.
SLAB REF. PLAN
#4 CONT.
2x PRE-TREATED SILL PLATEW/ 5/8" DIA. HEAVY HEX BOLTS AT 48" O.C. MAX. (U.O.N.) REF. 1/S3 AT SHEARWALLS
SHEARWALL REF. PLAN
EDGE NAILING
3" C
LR.
2' -
0"
1' - 4"
.
CLR2"
CLR2"
FIRST FLOOR100' - 0"
B
2x PRE-TREATED SILL PLATEW/ 5/8" DIA. HEAVY HEX BOLT AT 48" O.C. MAX. (U.O.N.) REF. 1/S3 AT SHEARWALLS
#4 CONT.
SLAB REF. PLAN
EXTERIORSHEATHING
EDGE NAILING
#6 REINF. BARS @ 12" O.C. T&Bw/ #3 STIRRUPS AT 48" O.C.
2' -
0"TYP2" CLR
2' - 6"
CLR3"
1' - 10 1/2"
2x6 AT 16" O.C.
0.135x2 AT 12" O.C. OR AS REQUIRED PER
SHEAR WALL (REF. PLAN)
EXTERIORSHEATHING
FACE OF STUDS (TYP.)
COUNTINOUS SHEAR WALREF. PLAN
DETAIL "C"
DETAIL "C"
4"
2' -
0"
2
STEEL TUBE PER ARCH.
GLAZING PER ARCH
T.O. SLAB 100' - 0"
SLAB ON GRADE PER PLAN
WOOD POST PER SECTION (BEYOND)
8
S2.00
FIRST FLOOR100' - 0"
C
(3) #6 REINF. BARS T&Bw/ #3 STIRRUPS AT 48" O.C.
SLAB REF. PLAN
#4 CONT.
STOREFRONT GLAZING PER ARCH.
3" C
LR.
2' -
0"
.
1' - 4"
CLR2"
CLR2"
1' - 10"
6"
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
NOT FOR CONSTRUCTIO
N
S6.00
17XXX
[Project Status]
[Date]
FOUNDATIONDETAILS
EL P
OLL
O L
OC
O29
95 T
EMPL
ATE
FOR
STA
TE O
F AR
IZO
NA
3/4" = 1'-0"3
GRADE BEAM AT BUMP OUT 3/4" = 1'-0"
1PERIMETER GRADE BEAM
3/4" = 1'-0"4
EXTERIOR SHEAR WALL FOUNDATION
3/4" = 1'-0"8
SECTION @ INTERIOR GLAZING
3/4" = 1'-0"5
GRADE BEAM AT STOREFRONT
REVISIONS
NO. DATE DESCRIPTION
NOT USED
NOT USED
NOT USED
OPEN
(2) SIMPSON A35FOR ONE TRUSS EACH SIDE OF KING STUD
KING STUDREF. PLAN
SIMPSON A35 EACH SIDE (2 TOTAL)
SIMPSON A35 EACH SIDE
(2 TOTAL)
SIMPSON HUCHANGER
HEADER REF. PLAN
TRIMMERSREF. PLAN
EDGE NAILING
REF. S3
SIMPSON LTS12AT 16" O.C.
BOUNDARY NAILING
EDGE NAILING
2x LEDGER W/ HANGERS & (3)16d AT 24" O.C. & 16d AT 8" O.C.TO TOP CHORD
PROVIDE VERTS.AT 16" O.C.
2-2x6 CONT. FROM BLDG.
CORNER
T.O. PARAPET
REF. ARCH'L.
2x6 STUDSAT 16" O.C.
SIMPSON H2AAT 16" O.C.
NAIL PERSCHEDULE
2x6 BLOCKING AT 16" O.C.
W/ SIMPSON A35AT EACH END
GIRDER TRUSSREF. PLAN
4
STUD OR STUDSTO MATCH TRUSSVERTICAL LEG
TRUSSTRUSS
A34 TYP.
PLYWOOD& BLOCKINGBEYOND
SIMPSON H2.5A AT EACH TRUSS,TYP.AT BUILDING CORNERS, SIMPSON H3 (EA SIDE - WITHIN 5'-0")
TOP PLATE OR BEAM
A34 TYP.
A34 TYP.
EDGE NAILING
STRAP REF. PLAN
BOUNDARYNAILING
LEDGERREF. PLAN
2x LEDGER W/(2) 16d TO STUDOR BLOCKING
TRUSS REF. PLAN
POST REF. PLAN
BOUNDARYNAILING
PANEL BLOCKING W/ 8d AT 6" O.C.
SIMPSON H2AAT 16" O.C.
2x6 STUDSAT 16" O.C.
REF. S3
4
2' - 0"
2
S8.00
SPLICE PARAPETTOP PLATE AS INDICATED ON PLAN
GIRDER TRUSSREF. PLAN
POST REF. PLAN
2x BLOCKING
SIMPSON HTSREF. PLAN
2x BLOCKING
SIMPSON A35AT 16" O.C. (U.O.N.)
LEDGER BEYOND
LINE OF PARAPET BEYOND
STRAP REF. PLAN
MIN.
3 4
MIN.
BN
2
S7.00ROOF DECK
ROOF DECK
EDGE NAILING
3x4 FLAT BLOCKING
DOUBLE 2x BLOCKING ATTACHED TO ROOF JOIST W/
SIMPSON PF 26A HANGERSAT EACH HOOD HANGER
L3x3x1/4x0'-6"W/ (2) 1/2" DIAMETER A307 BOLTSTO BLOCKING
VIBRATION ISOLATOR WHERE NECESSARY (TYP. OF 4)
1/2" DIAMETER HANGER ROD (TYP. OF 4)REF. PLAN FOR HOOD LOCATIONSHOOD
REF. PLAN
1/8" DIA. BRAIDED WIRE BRACING (4 TOTAL) AT 45 DEGREES, TYP.
7'-0
" MAX
2x LADDER FRAMING PER PLAN
HANGER
TRUSS REF. PLAN
EQUIPMENT SECURE PERMANUF. SPECS.
TRUSS ORBLOCKINGREF. PLAN
4x SLEEPERS ATPERIMETER OF
PLATFORM
ROOF SHEATHING
(1) SIMPSON A35 ATEACH TRUSS LOCATION
OR AT 24" O.C. (MIN OF 2 EACH SIDE) ATPERIMETER OF MECH'L.PLATFORM. SECURE W/
#10x1" GALV. SCREWS
NOTE: CONTRACTOR TO VERIFYPENETRATIONS W/ ROOF WARRANTY
BOUNDARY NAILING
ROOF ACCESS
2x REF. PLAN
TRUSS BEYOND
1 1/2"
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
NOT FOR CONSTRUCTIO
N
S7.00
17XXX
[Project Status]
[Date]
ROOF FRAMINGDETAILS
EL P
OLL
O L
OC
O29
95 T
EMPL
ATE
FOR
STA
TE O
F AR
IZO
NA
1" = 1'-0"1
HEADER 1" = 1'-0"
2WALL RETURN
1" = 1'-0"3
TRUSS INFILL PARAPET 1" = 1'-0"
4DRAG STRUT
1" = 1'-0"5
DRAG TRUSS
1" = 1'-0"7
TRUSS BAY BLOCKING & ROOF DECK BLOCKING 1" = 1'-0"
8HOOD CONNECTION DETAIL
1" = 1'-0"6
TRUSS BAY BLOCKING
1" = 1'-0"9
RTU CURB 1" = 1'-0"
10OPENING IN ROOF
REVISIONS
NO. DATE DESCRIPTION
TRUSS BEARING111' - 2"
A
T.O. HIGH PARAPET123' - 5"
2-2x6 TOP PLATE
2x6 VERTICAL LEG OR TRUSS
2x6 BLOCKING & SIMPSON LTP4AT 16" O.C. BETWEEN 2x6
2x6 BLOCKING W/10d AT 4" O.C. TO WALL BLOCKING
ROOF SHEATHING
PRE-FAB TRUSS REF. PLAN
SIMPSON H2.5A AT EACH TRUSS,TYP.AT BUILDING CORNERS, SIMPSON H3(EA SIDE - WITHIN 5'-0")
2-2x6 TOP PLATE
2x6 AT 16" O.C.
BOUNDARY NAILING
SHEAR WALL PLYWOODSHEATHING
SIMPSON A34 TO 2x6 PARAPETINFILL STUD
TRUSS BEARING111' - 2"
A (2) 2x6 TOP PLATE
2x6 BLOCKING
2x6 BLOCKING W/ 10d AT 4" O.C. TO WALL BLOCKING
ROOF SHEATHING
2x6 AT 16" O.C. BETWEEN TRUSSES
PLYWOODSHEATHING
SIMPSON A34 TO 2x6 PARAPETINFILL STUD
3
S7.00
T.O. PARAPET121' - 0"
4x BLOCKING AT EXTERIOR ELEMENT SUPPORTS
PRE-FAB TRUSS REF. PLAN
SIMPSON H2.5A AT EACH TRUSS,TYP.AT BUILDING CORNERS, SIMPSON H3(EA SIDE - WITHIN 5'-0")
2-2x6 TOP PLATE
2x6 AT 16" O.C.
TRUSS BEARING111' - 2"
5
2x6 BLOCKING
BOUNDARY NAILING
SIMPSON H2A AT EACH STUDTO BLOCKING
2x6 LEDGER W/ (3)10d AT EACH STUD
2x6 BRACE AT 16" O.C.w/ (4) 10d TO 2x6
BLOCKING EACH END
2x6 CONT.W/ (3) 10d
AT EACH STUD
SIMPSON A35AT EACH STUD
2-2x6 TOP PLATE
2x6 AT 16" O.C.
ROOF DECK
2x6 BLOCKINGAT 16" O.C.
2x6 AT EACH STUDW/ SIMPSON LU26EACH END
T.O. PARAPET121' - 0"
TRUSS BEARING111' - 2"
2-2x6 TOP PLATE
2x6 AT 16" O.C.
ROOF DECK
10d AT 4" O.C. TO BLOCKING
2x8 BLOCKING AT EACH STUDIN 1ST TWO BAYS
SIMPSON LSTA12 AT BLOCKING
2x6 BLOCKING
BOUNDAR NAILING
2x JOIST AT WALL W/ (4) 10d AT EACH STU & 10d AT 4" O.C. TO
BLOCKING
SIMPSON H2A AT EACH STUD
T.O. LOW PARAPET118' - 11"
T.O. MID PARAPET120' - 0"
TRUSS BEARING111' - 2"
C
2-2x6 TOP PLATE
2x6 AT 16" O.C. BETWEEN TRUSSES
2x6 VERTICAL LEG OF TRUSS
2x6 BLOCKING
2x6 BLOCKING W/(3) 10d TO INFILL STUD & 10d AT 4" O.C. TO WALL BLOCKING
ROOF DECK
SIMPSON H2. 5A AT EA. INFILL STUD
SHEAR WALLPLYWOOD SHEATHING
SIMPSON A34 TO 2x6 PARAPET INFILL STUD
PRE-FAB TRUSSREF. PLAN
T.O. GLAZING = 109' - 10"
CANOPYBY OTHERS
BEAM PER PLAN
6x BLOCKING AT CANOPY TENSION ROD SUPPORT w/ A35 EA END
GLAZING PER ARCH.
TRUSS BEARING111' - 2"
B
T.O. HIGH PARAPET123' - 5"
2x6 AT 16" O.C. BETWEEN TRUSSESW/ SIMPSON LTP4 AT 32" O.C.
2x6 BLOCKING W/ (3) 10d TO INFILL STUD10d AT 4" O.C. TO WALL BLOCKING
ROOF SHEATHING
PRE-FAB TRUSSREF. PLAN
SIMPSON H2.5AAT EACH TRUSS
BEAM PER PLAN
PLYWOODSHEATHING
BOUNDARY NAILING
SHEAR WALLPLYWOOD
SHEATHING
SIMPSON A34TO 2x6 PARAPET
INFILL STUD
3
S7.00 2-2x6 TOP PLATE
CANOPYBY OTHERS
AWNING (BY OTHERS)
6x BLOCKING AT CANOPY TENSION ROD SUPPORT w/ A35 EA END
GLAZING PER ARCH.
T.O. GLAZING = 109' - 10"
CANOPY BY OTHERS
T.O. WALL = 120' - 0"
T.O. WALL = 123' - 5"
T.O. WALL = 118' - 11"
T.O. WALL = 118' - 11"
T.O. WALL = 121' - 9"
T.O. WALL = 121' - 0"
T.O. WALL = 123' - 5"
RT- 12,400#
RT- 22,400#
KF- 2352#
KF- 1352#
KF- 396#
MAU- 11,412#
T.O. SLAB 100' - 0"
MONOSLOPE TRUSS, TYP.
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT
PROJECT #
SHEET NUMBER
NOT FOR CONSTRUCTIO
N
S8.00
17XXX
[Project Status]
[Date]
ROOF FRAMINGDETAILS,
ISOMETRIC VIEW
EL P
OLL
O L
OC
O29
95 T
EMPL
ATE
FOR
STA
TE O
F AR
IZO
NA
3/4" = 1'-0"4
ROOF FRAMING SECTION 3/4" = 1'-0"
3ROOF FRAMING SECTION 3/4" = 1'-0"
1ROOF FRAMING SECTION 3/4" = 1'-0"
2ROOF FRAMING SECTION 3 @ MID ROOF
3/4" = 1'-0"6
ROOF FRAMING SECTION @ GLAZING 3/4" = 1'-0"
5ROOF FRAMING SECTION
73D ISOMETRIC VIEW
REVISIONS
NO. DATE DESCRIPTION
VENTILATION SCHEDULE (ASHRAE 62.1)
RT. # MINIMUM VENTILATION DESIGN VENTILATION SUPPLY RETURN
TOTAL VENTILATION
RT-1 900 900 4375 3475
RT-2 900 900 4375 3475
1800
MECHANICAL SYMBOLS & SPECIFICATIONS
18"/24"
12"SD1
325 CFM
12"SD2
325 CFM
24"X24"RG1
EG1
400 CFM
T
RT
X
12"SD4
325 CFM
S
F
12"SD3
325 CFM
EF
X
CONNECT TO EXISTING
RECTANGULAR SHEET METAL DUCTWORK, SIZE IS AIRSIDE. FABRICATION, GAUGES, AND REINFORCING IN ACCORDANCE WITH SMACNA STANDARDS FOR 2" W.C. PRESSURE. LINE ALL RECTANGLE SUPPLY DUCTS WITH 1" THICK 1-1/2 LB. DENSITY NON SLOUGH FINISH GLASS FIBER DUCT LINER. INSULATE ALL ROUND SUPPLY SHEET METAL DUCTWORK WITH 1-1/2" FACED GLASS RISER DUCT WRAP.
SLOPE UP OR DOWN IN DUCTWORK. COORDINATE DUCTWORK WITH EXISTING CONDITIONS AND PROVIDE OFFSET AS NECESSARY.
LAY-IN SUPPLY DIFFUSER, NECK SIZE AND CFM. SIMILAR TO TITUS TDC LOUVERED FACE AND FRAM TO FIT 24"X24" INVERTED T-BAR CEILING.. WHITE FINISH STEEL. PAINT DIFFUSER TO MATCH ADJACENT CEILING COLOR. COORDINATE COLOR WITH ARCHITECT. CONNECT TO DIFFUSER WITH NECK SIZE INSULATED ROUND FLEXIBLE DUCT SIMILAR TO THERMAFLEX TYPE "G-KM" MAXIMUM 6'-0" IN LENGTH. CONNECT TO TRUNK DUCT WITH SPIN-IN FITTING, ADJUSTABLE BALANCING DAMPER AND ROUND SHEET METAL DUCTWORK. IN RUNS EXCEEDING 6'-0" INSULATE ROUND SHEET METAL DUCTWORK WITH 1-1/2" FACED GLASS FIBER DUCT WRAP. PROVIDE DIFFUSERS WITH OPTIONAL VOLUME DAMPER. PROVIDE DIFFUSER WITH TITUS TRM RAPID MOUNT FRAME FOR INSTALLATION IN GYP. BOARD CEILING.
LAY-IN SUPPLY DIFFUSER, NECK SIZE, AND CFM, 24"X24". SIMILAR TO TITUS PAS PERFORATED FACE AND FRAME TO FIT 24"X24" INVERTED T-BAR CEILING. WHITE FINISH STEEL. INSTALLATION CHARACTERISTICS SIMILAR TO SD1. PROVIDE DIFFUSERS WITH OPTIONAL VOLUME DAMPER.
SURFACE MOUNT SUPPLY DIFFUSER, NECK SIZE AND CFM. SIMILAR TO TITUS TDC LOUVERED FACE 18"X18". WHITE FINISH STEEL. PAINT DIFFUSER TO MATCH ADJACENT CEILING COLOR. COORDINATE COLOR WITH ARCHITECT. PROVIDE DIFFUSERS WITH OPTIONAL VOLUME DAMPER. INSTALLATION CHARACTERISTICS SIMILAR TO SD1.
LAY-IN SUPPLY DIFFFUSER, NECK SIZE, AND CFM, 12"X12". SIMILAR TO TITUS TMS. INSTALLATION CHARACTERISTICS SIMILAR TO SD1. PROVIDE DIFFUSER WITH OPTIONAL VOLUME DAMPER.
LAY-IN RETURN GRILLE. SIMILAR TO TITUS 50F, 1"X1"X1" EGGCRATE GRILLE WITH FRAME TO FIT 24"X24" INVERTED T-BAR CEILING. WHITE FINISH ALUMINUM. WHERE INDICATED TO INSTALL IN GYP BOARD CEILING, PROVIDE TITUS MODEL TRM FLANGED FRAME FOR GYP BOARD MOUNTING OF LAY-IN FRAME.
SURFACE MOUNTED ALUMINUM EXHAUST GRILLE. GRILLE SIZE AND CFM. SIMILAR TO TITUS 355FL, WITH 35° FIXED DEFLECTION BLADES ON 1/2" CENTERS. FURNISH IN STANDARD WHITE FINISH. PROVIDE GRILLE WITH OPTIONAL OPPOSED BLADE DAMPER.
PROVIDE 5" STAINLESS CATEGORY III VENTING SYSTEM, UL LISTED WITH APPROVED HEAT RESISTAN SEALANT, BACKFLOW PREVENTER, VERTICAL CONDENSATION DRAIN, ROOF FLASHING AND ROOF CAP. ENTIRE SYSTEM SHALL BE IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS AND DIAGRAMS.
PROGRAMMABLE ROOM THERMOSTAT. PROVIDE MULTI-STAGE HEAT/COOL HEAT PUMP PROGRAMMABLE THERMOSTAT COMPATIBLE WITH INSTALLED EQUIPMENT AND LANDLORD'S SYSTEM. MOUNT THERMOSTAT AT 60" AFF AS COORDINATED WITH INTERIOR WALL FINISHES. PROVIDE COMPATIBLE REMOT SENSOR FOR SYSTEM WHEN INDICATED ON PLAN. INSTALL WITH ALL WIRES, NUMBER AS REQUIRED, IN CONDUIT TO MAKE SYSTEM FULLY OPERATIONAL IN ACCORDANCE WITH MANUFACTURER'S WIRING DIAGRAMS AS NECESSARY.
REMOTE TEMPERATURE SENSOR FOR THERMOSTAT WHEN INDICATED ON PLAN. INSTALL SENSOR AT 60" AFF AS COORDIANTED WITH INTERIOR WALL FINISHES.
NEW ROOFTOP UNIT. UNIT SHALL BE OF MANUFACTURER AND MODEL AS SCHEDULED OR APPROVED EQUAL. UNIT SHALL BE U.L. LISTED AND RATED IN ACCORDANCE WITH ARI STANDARDS. UNIT SHALL HAVE ENTHALPY CONTROLLED ECONOMIZER CYCLE WITH BAROMETRIC RELIEF TO UTILIZE OUTSIDE AIR FOR COOLING WHEN OUTSIDE ENTHALPY IS LESS THAN RETURN AIR. PROVIDE STAGED HEATING AND COOLING PROGRAMMABLE THERMOSTAT WITH 'AUTO-ON-OFF" FAN SWITCH, CRANKCASE HEATER AND SHORT CYCLE PROTECTION CIRCUIT. CONTROL WIRING, INCLUDING T'STAT AND SMOKE DETECTOR SHUT DOWN WHERE REQUIRED, SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR. WIRING SHALL BE RUN CONCEALED IN FINISHED AREAS. CONDENSATE SHALL BE TRAPPED PER MANUFACTURERS RECOMMENDATIONS, 3/4" PIPING SHALL TERMINATE OVER JANITORS SINK OR AS OTHERWISE APPROVED BY LOCAL JURISDICTION. ELECTRICAL DRAWINGS ARE BASED ON MECHANICAL EQUIPMENT AS SCHEDULED. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ELECTRICAL REQUIREMENTS FOR ACTUAL EQUIPMENT SUPPLIED WITH THE ELECTRICAL CONTRACTOR AND SHALL PAY ANY COST ASSOCIATED WITH REVISIONS TO ELECTRICAL WORK.
EXHAUST FAN. FAN SHALL BE ROOF MOUNTED WITH CHARACTERISTICS AS SCHEDULED. PROVIDE MANUFACTURER'S ROOF CURB FOR INSTALLATION. ELECTRICAL DRAWINGS ARE BASED ON THE EQUIPMENT AS SCHEDULED. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ELECTRICAL REQUIREMENTS FOR ACTAUL EQUIPMENT SUPPLIED WITH THE ELECTRICAL CONTRACTOR AND SHALL PAY ANY COSTS ASSOCIATED WITH REVISIONS TO ELECTRICAL WORK.
BUILDING AIR BALANCE SCHEDULE
EQUIP. # OA SUPPLY CFM EXHAUST CFM TOTAL
RT-1 900 - 900
RT-2 900 - 900
MAU-1
KF-1
KF-2
KF-3
EF-1
BUILDING TOTAL CFM
8520 - 8520
- 4400 -4400
- 4400 -4400
- 600 -600
- 360 -360
+560
DUCT BRACING AND SUPPORTS SHALL BE OF NONCOMBUSTIBLE MATERIAL BOLTS, SCREWS, RIVETS, AND OTHER MECHANICAL FASTENERS SHALL NOT PENETRATE DUCT WALLS.JOINTS AND SEAMS SHALL BE MADE WITH CONTINUOUS WELD OR BRAZE MADE ON THE EXTERNAL SURFACE OF DUCT.
DUCTS SERVING A TYPE 1 HOOD SHALL BE CONSTRUCTED TO AVOID GREASE POCKET, THE DUCT SYSTEM SHALL HAVE A MINIMUM 1/4" SLOPE TOWARD HOOD OR GREASE COLLECTING DEVICE: PROVIDE CLEANOUT DOOR IF DUCT ON HORIZONTAL ANGLE AND FIRE RESISTANT ACCESS DOOR TO SHAFT ENCLOSURE.
AIR VELOCITY WITHIN TYPE 1 HOOD EXHAUST DUCT SHALL BE 1500 TO 2500 FPM.
PROVIDE MINIMUM OF 3" AND MAXIMUM OF 12" CLEARACE BETWEEN TYPE 1 HOOD DUCT AND FIRE RATED ENCLOSURE.
EXHAUST OUTLETS OF BOTTOM HORIZONTAL CENTRIFUGAL FANS SHALL BE MIN 2 FT. ABOVE THE ROOF. EXHAUST OUTLETS SERVING GREASE DUCT SYSTEMS AND POWER ROOF VENTILATORS FOR RESTAURANT COOKING APPLIANCES SHALL BE 40 INCHES ABOVE ROOF SURFACE, 10 FT. ABOVE ADJOINING GRADE, 10 FT. FROM BUILDING STRUCTURE AND/OR PARAPETS.
THE FIRE-EXTINGUISHING SYSTEM SHALL BE INTERCONNECTED TO THE FUEL AND/OR CURRENT SUPPLY SO THAT THE FUEL OR CURRENT IS AUTOMATICALLY SHUT OFF TO ALL EQUIPMENT UNDER THE HOOD WHEN THE SYSTEM IS ACTUATED. INSTAL AN AUTOMATIC FIRE SPRINKLER SYSTEM WHENEVER THE BUILDING IS FULLY SPRIKLERED. ACCESS DOORS ARE REQUIRED FOR SERVICE AND REPLACEMENT AT EACH SPRIKLER.
PROVIDE AT LEAST ONE PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 10BC FOR KITCHEN AREA.
HOOD EXHAUST NOTES
MECHANICAL DESIGN IS BASED ON 2012 INTERNATIONAL MECHANICAL CODE.ALL DUCTS TO COMPLY WITH 2012 IMC. ALL TRANSVERSE JOINTS TO BE SEALED WITH TAPE OR MASTIC. ALL LOW PRESSURE DUCT WORK SIZED EQUAL TO OR LESS THAN 0.1"W.G./100 FT.
INSTALLATION OF DUCT WORK SHALL BE COORDINATED WITH ALL OTHER TRADES.
PROVIDE MASTIC OR DUCT TAPE JOINT SEALANT TO SEAL TRANSVERSE JOINTS ON AIR SUPPLY DUCTS INSTALLED IN LOCATIONS WHERE AIR LEAKAGE THROUGH THE JOINTS WOULD BE NONBENEFICIAL TO THE OCCUPIED AREA TEMPERATURE REQUIREMENTS. AND , SEAL LONGITUDINAL JOINTS ON LOW PRESSURE SUPPLY DUCTS WHERE INTERNAL STATIC PRESSURE EXCEED 0.75" OF WATER COLUMN.
EQUIPMENT AND DUCT WORK EXPOSED TO WEATHER TO BE WEATHERPROOF. VERIFY WITH THE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR EXACT LOCATION OF DUCT OPENINGS ON ROOF.
ALL WORKS SHALL COMPLY WITH REQUIREMENTS OF ALL APPLICABLE CODES LAWS ORDINANCES AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS PLAN CHECK FEES, INSPECTIONS, ETC. AND FURNISH SIGNED, CERTIFIED AND ACCEPTABLE COPIES TO THE OWNER FOR HIS RECORD.
TOILET EXHAUST FAN DUCTS SHALL BE OF SMOOTH, NON-ABSORBENT AND NON-COMBUSTIBLE SURFACE MATERIAL.
ALL OSA INTAKES MUST BE A MINIMUM OF 10'-0" AWAY FROM TOILET OR KITCHEN HOOD EXHAUST DISCHARGE, PLUMBING OR APPLIANCE VENT (OR 3'-0" MINIMUM BELOW VENT).
MANUAL VOLUME DAMPER OR ADJUSTABLE EXTRACTORS TO BE INSTALLED IN ALL BRANCH TAKE-OFFS. ALL DAMPERS TO HAVE LOCKING QUADRANTS.
ALL AIR CONDITIONING UNITS TO BE FURNISHED WITH MAINTENANCE MANUALS, SCHEDULES AND TAGS.
ALL LOW VOLTAGE WIRING SHALL CONFORM MECHANICAL SECTION.
THE MECHANICAL CONTRACTOR SHALL GUARANTEE ALL EQUIPMENT, APPARATUS ACCESSORIES (I.E. THE ENTIRE INSTALLATION) AS FURNISHED BY HIM FOR A PERIOD OF ONE YEAR.
THE MECHANICAL CONTRACTOR SHALL OBTAIN & PAY FOR ALL PERMITS, LICENSES & INSPECTIONS REQUIRED FOR THIS JOB.
COORDINATE THE SIZE, LOCATION AND SERVICE REQUIREMENTS OF ALL MECHANICAL EQUIPMENT & DUCTWORK WITH THE GENERAL, PLUMBING, ELEC. CONTROL & FIRE PROTECTION CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. REPORT ALL UNSOLVED CONFLICTS TO THE OWNER.
COORDINATE THE LOCATION OF ALL CEILING DIFFUSERS, REGISTERS, GRILLES & ETC. WITH THE ARCHITECTURAL REFLECTED CEILING PLAN.
FLEXIBLE CONNECTIONS SHALL BE PROVIDED FOR ALL DUCTWORK ATTACHED TO AIR MOVING EQUIPMENT MOUNTED VIBERATION ISOLATORS AND OR SUSPENDED FROM VIBRATION HANGERS.
THE ELECTRICAL AND PLUMBING CONTRACTORS SHALL PROVIDE FLEXIBLE CONNECTIONS AT ALL MECHANICAL EQUIPMENT MOUNTED ON VIBRATION ISOLATORS AND OR SUSPENDED FROM VIBRATION HANGERS.
ALL CONDENSATE DRAIN LINES RUNNING INSIDE BUILDING SPACES SHALL BE INSULATED WITH JOHN'S-MANVIL "AEROTUBE" TYPE PREFORMED SNAP-ON PLASTIC INSULATION.
PROVIDE ALL FIRE AND SMOKE DAMPERS AS REQUIRED BY LEGALLY CONSTITUTED AUTHORITIES AND CODES HAVING JURISDICTION.
PAINT PLENUM BEHIND EACH GRILLE OR REGISTER WITH FLAT BLACK PAINT.
BALANCE AND ADJUST ALL DIFFUSERS ,REGISTER, ETC. FOR OPTIMUM AIR DISTRIBUTION AND MINIMUM NOISE. SUBMIT A CERTIFIED AIR BALANCE REPORT TO THE MECHANICAL ENGINEER FOR APPROVAL. BALANCING OF THE SYSTEMS SHALL BE PERFORMED BY AN INDEPENDENT TEST & BALANCING AGENCY WHICH SPECIALIZES IN THE BALANCING & TESTING OF HEATING VENTILATING AND AIR CONDITIONING SYSTEMS.
ALL AIR CONDITIONING FILTERS SHALL BE REPLACED ON DAY OF BALANCING PRIOR TO TESTING. ALL EXPOSED AIR DISTRIBUTION SYSTEM (DUCTWORK, CD, CRR, ETC.) SHALL BE PAINTED AS PER PLAN OR DIRECTED BY ARCHITECT.
CONTRACTOR TO VISIT THE JOB & INFORM OWNER OF ANY PROBLEMS OR DISCREPANCY BEFORE STARTING THE JOB.
LABEL AIR CONDITIONING UNITS OR DEVICES WITH SPACE NAME AND NUMBER.
ALL HORIZONTAL DUCTS AT SOFFIT AREA SHALL BE INSIDE THE SOFFIT.
ALL EXPOSED DUCTWORK SHALL BE AS CLOSE TO WALLS & ROOF DECK AS POSIBLE.
PROVIDE ALL TRASITIONS AS REQUIRED FROM MAIN DUCT OR BRANCHES TO DIFFUSERS OR REGISTERS OR GRILLES.
ALL DIFFUSERS AND REGISTERS SHALL BE INSTALLED AS HIGH AS POSSIBLE.
ALL NEW DUCTWORK SHALL BE INSTALLED AS HIGH AS POSSIBLE.
-GENERAL CONTRACTOR PROVIDE ALL NECESSARY EQUIPMENT CURBS, RUNNERS AND PLATFORMS. PROVIDE ALL NECESSARY ROOFING, PATCHING, CUTTING, RATED SHAFTS, FURRING, FLASHING AND PAINTING.
-PLUMBING CONTRACTOR PROVIDE ALL NECESSARY DRAINS, GAS, CONDENSATE DRAINS WITH TRAPS, MAKE-UP WATER, INCLUDING FINAL CONNECTIONS.
-ELECTRICAL CONTRACTOR FURNISH AND INSTALL ALL LINE VOLT. WIRING, ALL CONDUITS AND AUXILIARIES AS SHOWN ON PLANS.
GENERAL NOTES
NOTES:
1. AN AIR BALANCE TEST WILL BE REQUIRED TO VERIFY THE PROPER VOLUME OF OUTSIDE AIR TO COMPLY WITH THE 2012 IMC, BEFORE THE FINAL APPROVAL OF THIS PROJECT.
2. AIR HANDLING DUCT SYSTEMS SHALL BE CONSTRUCTED, INSTALLED AND INSULATED AS PROVIDED IN CHAPTER 6 OF THE 2012 IMC.
3. PRIOR TO FINAL APPROVAL OF THE MECHANICAL PERMIT, A SMOKE DETECTOR SHUT-OFF TEST SHALL BE REQUIRED.
4. SEAL PENETRATIONS THROUGH SMOKE BARRIER PER 2012 IBC.
5. A PERFORMANCE TEST WILL BE REQUIRED TO VERIFY THE RATE OF AIRFLOW AND THE PROPER OPERATION OF THE EXHAUST AND MAKE-UP AIR FOR KITCHEN HOOD SYSTEM BEFORE THE FINAL APPROVAL OF THIS INSTALLATION.
6. SMOKE DETECTORS SHALL BE LABELED BY AN APPROVED AGENCY APPROVED AND LISTED BY THE TEXAS STATE FIRE MARSHALL FOR AIR DUCT INSTALLATION AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S APPROVED INSTALLATION INSTRUCTIONS.
7. INSTALLATIONS OF HVAC, REFRIGERATION, AND FIRE SUPPRESSION EQUPMENT SHALL NOT CANTAIN CHLOROFLUOROCARBONS (CFCS) OR HALONS.
NOTES: #2
ALL ROOF MOUNTED EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW.
FOR HOOD PLANS SEE HOOD MANUFACTURER'S DRAWINGS PROVIDED BY "CAPTIVEAIRE".
FOR MOBILE EQUIPMENT, POSI-SETS SHALL BE INSTALLED BELOW REAR CASTERS OF THE EQUIPMENT PER NFPA 17A.5.6.4. USE OF THE POSI-SET WHEEL PLACEMENT SYSTEM WILL ENSURE THAT SPECIFIC COOKNG EQUIPMENT IS REPLACED IN THE PROPER LOCATION AFTER REMOVAL.
REFRIGERANT SERVICE PARTS LOCATED OUTDOORS SHALL BE FITTED WITH LOCKING TYPE TAMPER-RESISTANT CAPS OR SHALL BE PROTECTED FROM UNAUTHORIZED ACCESS BY MEANS ACCEPTABLE TO THE ENFORCING AGENCY.
PRIOR TO MECHANICL PERMIT FINAL, A SMOKE DETECTOR SHUT-OFF TEST WILL BE REQUIRED. 2012 IMC.
NOTE:
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
M1.00
XXXXX
BID & PERMIT
XX-XX-XX
SCHEDULES ANDREQUIREMENTS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1.2.3.4.5.6.7.
GAS ROOFTOP UNIT SCHEDULE
DESIGNATION
MFGR. MODEL CFM E.S.P. "W.C.
COOLING (MBH) HEATING (MBH)
EER VOLTS PHASE MCA MOCP NOTES WEIGHTTYPE # TOT. AMB INPUT OUTPUT
RT 1 TRANE YZD150G3RLA 4,375 CFM 0.88 in-wg 150.0 105 °F 150.0 122.0 12.5 208 V 3 71 A 80 A 1,3,4,5,6 2,400
RT 2 TRANE YZD150G3RLA 4,375 CFM 0.88 in-wg 150.0 105 °F 150.0 122.0 12.5 208 V 3 71 A 80 A 1,3,4,5,6 2,400
EXHAUST FAN SCHEDULE
DESIGNATION
MFGR. MODEL CFM S.P. HP VOLTS PHASE FLA NOTES WEIGHTTYPE #EF 1 COOK ACEB-80C2B 360 CFM 0.375 in-wg 1/6 120 V 1 4.0 A 4,5,6 50
KF 1 CAPTIVEAIRE CASRE24BD 4,400 CFM 1.200 in-wg 5 208 V 3 18.8 A 1,2,3,5,8 352
KF 2 CAPTIVEAIRE CASRE24BD 4,400 CFM 1.200 in-wg 5 208 V 3 18.8 A 1,2,3,5,8 352
KF 3 CAPTIVEAIRE NCA8FA 600 CFM 0.500 in-wg .5 208 V 3 1.9 A 1,2,3,5,8 96
INTERLOCK FAN WITH RT1, RT2, RT3.PROVIDE FAN WITH GREASE SCOPE AND GREASE COLLECTOR.FAN SHALL BE NFPA 96 APPROVED.INTERLOCK FAN TO RUN DURNING 'OCCUPIED' OPERATION OF ROOFTOP UNIT 'RT-1'.PROVIDE FAN WITH STANDARD DISCONNECT.PROVIDE FAN WITH BACKDRAFT DAMPER.PROVIDE FAN WITH MOTORIZED DAMPER.PROVIDE FAN WITH VENTED ROOF CURB AND HINGED BASE.
NOTES:
1.2.3.4.5.6.7.8.
PROVIDE UNIT WITH 14" LOW PROFILE ROOF CURB AND MANUFACTURER'S HOLD DOWN CLIPS.PROVIDE UNIT WITH 100% ENTHALPY CONTROL ECONOMIZER HOOD AND OUDOOR AIR INTAKE, AND BAROMETRIC RELIEF.PROVIDE WITH CONVENIENCE RECEPTACLE ON ROOF AND HAIL GUARDS.INTERLOCK UNIT WITH KF1, KF2, AND KF3.COORDINATE SMOKE DETECTOR INSTALLATION AND AUTOMATIC SHUT-OFF REQUIREMENTS WITH FIRE ALARM CONTRACTOR.UNIT SHALL BE FREON-FREE.PROVIDE UNIT WITH REMOTE OPERATOR DISPLAY, MOTORIZED DAMPER, HINGED ACCESS PANELS.
NOTES:
MAKE-UP AIR UNIT
DESIGNATION
MFGR. MODEL CFMSTATIC
PRESSURE
EVAP COOLING
VOLTS PHASE MCA MOCP NOTES WEIGHTTYPE # ENT. DB LEAVING DBMAU 1 CAPTIVEAIRE A4-920 8,520 CFM .750 in-wg 100.0 65.0 208 V 3 19 A 30 A 1,2,3,4,5 1,412
INTERLOCK MAU WITH KF1, KF2, KF3.PROVIDE UNIT WITH EVAPORATIVE COOLER.PROVIDE UNIT WITH MANUFACTURER'S RECOMMENDED DISCONNECT.PROVIDE UNIT WITH REMOTE OPERATOR DISPLAY, MOTORIZED DAMPER, AND HINGED ACCESS PANELS.INTERLOCK MAU WITH HOODS 1,2,3 TO SHUT DOWN UPON FIRE SIGNAL FROM HOOD.
NOTES:
1.2.3.4.5.
REVISIONS
NO. DATE DESCRIPTION
S
T
S
AT THE TIME OF ROUGH INSTALLATION OR DURING STORAGE ON THE CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING AND COOLING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEETMETAL OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF DUST OR DEBRIS WHICH MAY COLLECT IN THE SYSTEM.
ALL RECTANGULAR DUCTWORK TO BE SHEET METAL WITH LINER PER SPECIFICATIONS. RECTANGULAR DUCTWORK DIMENSIONS SHOWN ARE AIRSIDE DIMENSIONS AND NEED TO BE INCREASED TO ACCOMODATE LINER WHEN APPLICABLE.
ROUND DUCTWORK DIMENSIONS SHOWN ARE AIRSIDE. RUNOUTS TO DIFFUSERS SHALL BE THE SAME SIZE AS DIFFUSER NECK UNLESS INDICATED OTHERWISE.
COORDINATE EXACT ROUTING OF DUCTWORK WITH STRUCTURE. DUCTWORK LOCATIONS SHALL HAVE PRECEDENCE OVER SPRINKLER PIPING.
COORDINATE THERMOSTAT AND SENSOR LOCATIONS WITH WALL ELEVATIONS. INSTALL THERMOSTATS AND SENSORS AT 60" AFF.
PRIOR TO OCCUPANCY, PROVIDE CLEAN FILTERS CAPABLE OF PROVIDING AT LEAST A MERV OF 11.
SPACE ABOVE CEILING IS LIMITED. COORDIANTE WITH STRUCTURE AND ROUTE DUCTS THROUGH AND BETWEEN ROOF JOISTS WHERE POSSIBLE.
1.
2.
3.
4.
5.
6.
7.
GENERAL MECHANICAL NOTES
12"SD1
420 CFM
12"SD1
420 CFM
12"SD1
420 CFM
12"SD1
420 CFM
12"SD1
420 CFM
12"SD1
420 CFM
12"SD1
420 CFM
12"SD2
450 CFM
12"SD2
450 CFM
12"SD2
450 CFM
12"SD2
450 CFM
12"SD2
450 CFM
6"SD4
100 CFM 6"SD4
100 CFM
12"x12"ER1
180 CFM12"x12"ER1
180 CFM
8"SD4
150 CFM
12"SD1
375 CFM
12"SD1
375 CFM
16"ø
16"ø
18"ø
24"x24"RG1
RT
2
RT
1
22"ø
1
2
3
4
4
4
5
6 12"x24"RG1
1
2
3 4
5
D.1
D
C
B
A
16"ø
16"ø
12"SD1
420 CFM
12"ø
12"SD1
420 CFM
12"SD1
420 CFM
5
5
24"x24"RG1
12"SD2
450 CFM
8"/8"
8"/8"
10"/10"
12"SD2
450 CFM
12"SD2
450 CFM
24"/20"
24"/20"
7
7
7
7 7
7
77
7
7
7777 16"/12"16"/12" 16"/12"
16"/12"16"/12"
16"/12"
22"/18"
7
16"/10"
24"x24"RG2
18"ø 18"ø
18"ø
24"x24"RG2
18"ø
18"ø
12"ø
20"ø
18"ø
22"ø22"ø
1
8"/8"
16"ø
12"ø
26"/26"
22"/26"
22"/18"
22"/20"
22"/18"
8
9
8"ø
24"x24"RG2
24"x24"RG2
10
MAU
1
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
M1.10
XXXXX
BID & PERMIT
XX-XX-XX
FLOOR PLAN -MECHANICAL
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
PLAN NOTES
1 LOCATE UNIT REMOTE TEMPERATURE SENSOR IN RETURN DUCT DROP.
2 LOCATION OF UNIT (RT1,RT2) THERMOSTATS.
3 EXTEND AND CONNECT EXHAUST DUCT UP TO FAN ON ROOF. PROVIDE FLEXIBLE CONNECTION ATFAN. SIZE AS INDICATED.
4 NEW TYPE 1 GREASE RATED EXHAUST HOOD. CONTRACTOR SHALL FURNISH AND INSTALL HOOD ASCOORDIANTED WTIH OWNER. MAINTAIN REQUIRED CLEARANCES FROM HOOD AND GREASE DUCT.RE: HOOD DETAILS FOR MORE INFORMATION.
5 GREASE EXHAUST DUCT UP TO GREASE EXHAUST FAN ON ROOF. SIZE AS INDICATED. MAKECONNECTION TO GREASE EXHAUST FAN AS REQUIRED.
6 EXTEND AND CONNECT GREASE DUCT DOWN TO HOOD AS REQUIRED. SIZE PER HOOD CONNECTION.RE: HOOD DETAILS FOR MORE INFORMATION.
7 EXTEND AND CONNECT MAKE-UP AIR DUCT DOWN TO HOOD. SIZE PER HOOD CONNECTION SIZE.BALANCE EACH DUCT CONNECTION PER HOOD DETAIL SHEETS. RE: HOOD DETAILS FOR MOREINFORMATION.
8 MAKE-UP AIR DUCT FROM UNIT ON ROOF ABOVE. SIZE AS INDICATED. EXTEND TO ABOVE CEILINGAND CAP.
9 ROUTE MAKE-UP AIR DUCTS BETWEEN AND THROUGH JOISTS.
10 ROUTE DUCTS BETWEEN AND THROUGH JOISTS SO AS TO NOT INTERFERE WITH CEILING ELEMENTSAND DECORATIVE LIGHTING ABOVE.
1/4" = 1'-0"1
FLOOR PLAN - MECHANICAL
REVISIONS
NO. DATE DESCRIPTION
KF
1
KF
2
KF
3
RT
1
RT
2
EF
1
OUTDOOR AIR/ECONOMIZER INTAKE. MAINTAIN 10' CLEARANCE FROM EXHAUST FANS AND PLUMBING VENTS.
OUTDOOR AIR/ECONOMIZER INTAKE. MAINTAIN 10' CLEARANCE FROM EXHAUST FANS AND PLUMBING VENTS.
1
2 3 4
5
D.1
D
C
B
A
OUTDOOR AIR INTAKE. MAINTAIN 10' CLEARANCE FROM EXHAUST FANS AND PLUMBING VENTS.
MAU
1
SUPPORT CONDENSATE PIPING ON TREATED WOOD BLOCKING SECURED TO ROOF AT 8' INTERVALS.
MAINTAIN 1/4" SLOPE TO DRAIN ON ALL CONDENSATE PIPING.
PROVIDE CLEANOUT PLUGS AT 90° CHANGES OF DIRECTION.
ALL ROOF MOUNTED EQUPMENT TO BE PROVIDED WITH RESTRAINTS. LOCATE AND SIZE RESTRAINTS PER BUILDING CODE, LOCAL AUTHORITIES, AND LOCAL WIND LOAD REQUIREMENTS.
COORDINATE FINAL LOCATIONS OF ALL HVAC UNITS, FANS AND MECHANICAL EQUIPMENT WITH STRUCTURE AND FIELD CONDITIONS.
ALL MECHANICAL EQUIPMENT ON ROOF SHALL BE SCREENED BY PARAPET.
MAINTAIN 10' CLEARANCE FROM ALL OUTDOOR AIR INTAKES. PROVIDE OUTDOOR AIR INTAKE EXTENSIONS AS REQUIRED AND COORDINATED WITH FIELD CONDITIONS.
1.
2.
3.
4.
5.
6.
7.
GENERAL MECHANICAL ROOF NOTES
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
M1.20
XXXXX
BID & PERMIT
XX-XX-XX
ROOF PLAN -MECHANICAL
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/4" = 1'-0"1
ROOF PLAN - MECHANICAL
REVISIONS
NO. DATE DESCRIPTION
PER CODE
OR STRAP
18 GA. WIRE
4'-0" MIN. LENGTH
6'-0" MAX. LENGTH
FLEXIBLE DUCT
SHEET METAL DIFFUSER
LOCKING INDICATING
MANUAL DAMPER WITH
AROUND BOX (TYP.)
BOX WITH INSULATION
QUADRANT
RECTANGULAR OR
ROUND DUCT
T-BAR CEILING
EXTENDED PANEL
CEILING DIFFUSER
T-BAR CEILING
CEILING DIFFUSER
EXTENDED PANEL
(TYPICAL)
QUADRANT
MANUAL DAMPER WITH
SHEET METAL DUCT
WITH INSULATION
LOCKING INDICATING
TAPE (TYP.)
BAND AND DUCT
FLEXIBLE DUCT
TO DUCT AND CURBSUPPORT, SECURE
4x4 CANT STRIP
ANGLE DUCT
FOR SIZESDUCT - SEE PLANS
ROOF
NOTE:
COUNTER FLASHINGFLASHING AND
POCKET LOCK
2x6 CURB
CONTRACTORCURBING BY GENERAL
ROOFING
ATTACH ROOF CURB TO ROFF STRUCTURE AND PROVIDE BLOCKING AS REQUIRED.
SEE ARCHITECTURAL DRAWINGS FOR ROOF OPENING AND CURB DETAIL.
MASTIC BETWEEN
REDWOOD & ROOF
ROOF LINE
WEATHER TIGHT DUCT
9"(MIN.)
1-1/2"X 1-1/2"X 1/4" DUCT SUPPORT
WELD TO SOLE PLATE AND SECURE
TO DUCT.
1"STANDING SEAM
2"X6"RED WOOD
RAFTER
32"O.C. 2" EMBED
1/4"∅ LAG SCREWS @
LAG SCREWS
SUPPORTS SHALL BE
8'-0" O.C. (MAX.)
FOUR 1/4"X1-1/2"
4"X4" PLATE
1/4" THICK
Thermal Ceramics
Commercial Kitchen Grease Duct Enclosure SystemAir Ventilation Duct Enclosure System
FireMaster FastWrap XL
1 or 2 Hour Shaft Alternative / Zero Clearance to Combustibles
The integrity of Firemaster duct systems is limited to the quality of the installation.
Steel Banding
3" longitudinal overlap
3" transverse overlap
Min. 3/8" diameter hanger rod
Two Layers of FireMaster FastWrap XL
LEGEND
1
7
4
6
5
3
2
BUTT-JOINT/COLLAR
24"
12"
1 1/2"
3"
1 1/2"
BUTT-JOINT/3"OVERLAP
10 1/2"
Filament tape
2" x 2" x 1/8" angle
R R
1
4
2 2
8
6
7
8
95
8
5
322
3
3
3
2 3
1" compressed butt joint
9
8
6" wide Firemaster FastWrap XL collar
Thermal Ceramics
60" MAXIMUM
1
3
2
5
3
4
The integrity of Firemaster duct systems is limited to the quality of the installation.
Min. 3/8" All-threaded rod
2"x2"x1/8" Steel Angle
Steel washer & nut sized to fit item 3
Floor/Ceiling Assembly
LEGEND
1
4
5
3
2 16 Gage Carbon Steel or 18 Gage Stainless Steel Duct
Maximum 24"X48" or 34"x36"
Horizontal Support DetailsFireMaster FastWrap XL
R
TYPICAL PENETRATION OF FLOOR/CEILING
FLOOR/CEILINGFLOOR/CEILING
6" MAXIMUM
Clearance From Edgeof Protected Duct
1. THERMAL CERAMICS FIREMASTER FASTWRAP XL OR PYROSCAT XL HAS BEEN TESTED IN
ACCORDANCE WITH ASTM E2336 TO PROVIDE ZERO CLEARANCE TO COMBUSTIBLES AND
MEETS THE REQUIREMENTS FOR ONE OR TWO HOUR ENCLOSURES. THROUGH
PENETRATIONS FIRESTOP SYSTEMS ARE TESTED IN ACCORDANCE WITH EITHER ASTM E 814
OR UL 1479. ICC-ES APPROVAL PER REPORT ESR 2213 OR ESR 2832. UNDERWRITER'S
LABORATORIES (UL) LISTINGS SHOW COMPLIANCE TO UL 1479 FOR THROUGH PENETRATION
FIRESTOP SYSTEMS.
2. COMPLIANT TO THE FOLLOWING CODES:
NFPA 96
2003 AND 2006 INTERNATIONAL MECHANICAL CODES
2006 UNIFORM MECHANICAL CODE.
3. INSULATION APPLIED IN TWO LAYERS WITH TIGHT COMPRESSION JOINT ON INSIDE LAYER
AND 3 INCH MINIMUM OVERLAPS ON BOTH PERIMETER AND LONGITUDINAL OVERLAPS ON
OUTSIDE LAYER.
4. GREASE EXHAUST DUCT RUNS FROM THE HOOD EXHAUST CONNECTION UP TO THE EXHAUST
FAN ON THE ROOF WITH MINIMAL TURNS OR BENDS AND MAINTAINING MINIMUM 1/4 UNIT
VERTICAL RISE PER 12 UNITS HORIZONTAL RUN. NFPA 96 COMPLIANT ACCESS DOORS
LOCATED AS REQUIRED BY CODE.
5. THERMAL CERAMICS FIREMASTER ACCESS DOORS AS SPECIFIED IN ICC-ES BUILDING CODE
REPORTS ESR 2213 OR ESR 2832.
6. ROOF MOUNTED EXHAUST FAN IS MOUNTED ON A HINGED BASE WHICH ALLOWS ACCESS TO
THE DUCT FROM THE ROOF.
7. SUPPORT HANGER SYSTEMS DO NOT NEED TO BE WRAPPED PROVIDED THE HANGER RODS
ARE AT LEAST A MINIMUM OF 3/8 IN. DIAMETER. USE MINIMUM 2 X 2 X 1/8 IN. STEEL ANGLE OR
SMACNA EQUIVALENT SUPPORT SYSTEM.
8. THERMAL CERAMICS DUCT ENCLOSURE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH
MANUFACTURERS INSTRUCTIONS.
9. THERMAL CERAMICS DUCT WRAP SHALL BE INSTALLED ON THE DUCT FROM THE HOOD
CONNECTION TO THE CONNECTION TO THE FAN.
Thermal Ceramics
The integrity of the duct wrap insulation product is limited to the quality of the installation
LEGEND
Access Door SystemsCommercial Kitchen Grease Duct Enclosure System
FireMaster FastWrap XL
FireMaster F2-HT-XL3 Door System
NOTE: Available from Thermal CeramicsFireMaster Distributors.
One layer Firemaster Duct Product56
234
1 Door hole
16 Gage Access coverAll Thread Rods (1/4")
Insulation pins - welded to plate or access cover
7
FireMaster Field Fabricated Door System
Note:Label Required
"Access Door"Do Not Obstruct
Note:Label Required
"Access Door"Do Not Obstruct
R
R
7
4
137
8
11
2
3
4
1011
1
2
3
6
5
8
12
6
5
1
9
One layer Firemaster Duct Product, 1 1/2" OverlapOne layer Firemaster Duct Product, 1 1/2" Overlap1-1/2" Round or Square Speed clips8
910
Aluminum tape at edgesSpool pieces for threaded rods (Field Fab. only)Wing nuts sized to fit All Threaded Rod in Item 211
1213
Washers sized to fit All Threaded Rods in Item 2Insulation Plate
BUILT UP ROOF
TO PLATFORM WITHSECURE ROOF CURB
RIGID INSULATION
ROOF CURB
3/8"∅ x 3" LONG
LAG BOLTS @24" O.C.
RESILIENT GASKET
SEE STRUCTURAL DWGSPLATFORM AND SUPPORTS
TOP OF PLATFORM
ROOFING MATERIAL
METAL COUNTERFLASHING
1" ROOFING NAILS @12" O.C.
AC UNIT
2"x 3/16" BENT GALV. STEELPLATE BRACKET. ONE NEAR EACHCORNER OF AC UNIT.(4 REQ'D)
2-3/8"∅ STEEL BOLTSCADMIUM PLATED W/LOCK WASHERS.
3/8"∅ LAG BOLTS,1-1/2" LONG
3/8"∅ LAG BOLTS,1-1/2" LONG
CANT STRIP
FOR ATTACHMENT TO ROOFSEE ARCHITECTURAL DRAWINGS.
20 GAGE SHEET METAL-WEATHERPROOF, WATERTIGHT, ALL CORNERSAND SEAMS SOLDERED
1/2" PLYWOOD -
PLATFORM FRAMEFOR FASTENING METHODSSEE STRUCTURAL DWGS.
FASTENED TO 2"x 6"
ROOF DECK
NOTE: COORDINATE INSTALLATION WITH ARCHITECTURAL DRAWINGS AND DETAILS.
ROOFING FELT AND
COMPLETE WATER-HOT MOP FOR A
ROOFING FELT OVER
CANT STRIPS, 4 SIDES
ENTIRE PLATFORM
4 SIDES AND CENTER4"x 6" PLATFORM
TIGHT SEAL
DISCONNECT SWITCH
FLASHED TO ROOFFLASHED AND COUNTER
ALUMINUM INSECT SCREEN
HOUSING RIGIDLY INSTALLEDEXHAUSTER WITH ALUMINUMBELT-DRIVEN CENTRIFUGAL
FACTORY MOUNTED INTERNAL
REMOVABLE ALUMINUM CAP
INSULATED CURB PROPERLY12" HIGH SOUND ATTENUATING
BACKDRAFT DAMPER
BLOCKING AS REQUIRED
FOR DUCT PENETRATION
MODIFIED AND RIGIDLY
ROOF AS REQUIREDSEAL PENETRATION OFTHROUGH ROOF CURB;
ELECTRICAL CONDUIT
SEE ARCHITECTURAL DRAWINGS FOR ROOF OPENING AND CURB DETAIL.
SIZE OF FAN CONNECTIONOPEN END DUCT EQUAL TO
& SECURE TO STRUCTURE
ROOF OPENING, PROVIDE
REINFORCED AS NEEDED FOR
ROOF STRUCTURE PROPERLY
FEET. SLOPE 1 INCH PER FOOT.
WHEN DUCT LENGTH EXCEEDS 75
CLEANOUT DOORS IN DUCTS
SHALL BE TIGHT FITTING.
VELOCITY: MAX. 2500
SLOPE DUCT TO HOOD MINIMUM 1/4" PER FOOT
2'-0" MINIMUM
ABOVE ROOFROOF ROOF
MOTORS AND FANS.
SEE REQUIREMENTS FORMAKE UP AIR INTAKE OR AIR INTAKES;
ADJACENT BUILDING; ADJACENT PROPERTY LINE;
EXHAUST TERMINATION -10' MINIMUM FROM
AND 10' ABOVE ADJOINING GRADE LEVEL.
TO BE MIN. 25 GAGE GALVANIZED STEEL
WEATHER PROTECTION FOR OPENINGS
TYPE I HOOD
18"
CEILING CEILING
18"MIN. FIRE
RATED WALL
ENCLOSE WITH 22 GA SHEET METAL
3" CLEARANCE
FROM WALL
2% SLOPE
GREASE
BOX
2) THE MAXIMUM TOTAL DEVELOPED LENGTH OF DUCT
SHALL NOT EXCEED 3 TIMES THE VERTICAL DIMENSION
AND FITTING MEASURED ALONG THE CENTRELINE
OF THE FAN OUTLET.
3) THE DUCT AND FITTING SHALL HAVE ADEQUATE OPENINGS
TO A SUITABLE COLLECTION DEVICE.
AT THE LOWEST POINT TO PERMIT DRAINAGE OF GREASE
GENERAL
REFER TO 2010 CMC
40" MINIMUM
1) THE DUCT SHALL BE CONSTRUCTED OF METAL IN
COMPLIANCE WITH 2010 CMC.
USE "THERMAL CERAMICS"
FIREMASTER DUCTWRAP XL
COMBUSTIBLE CEILING
18"MIN. NON-
NON-COMBUSTIBLE CEILING
7. SECTIONS OF DUCT SHALL NOT CONTAIN
SEAMS ON THE EXTERNAL SURFACE.
6. WELD OR BRAZE ALL DUCT JOINTS AND
STANDARD GAGE STAINLESS STEEL
GAGE) STEEL OR NO. 18 MANUFACTRER'S
0.055-INCH (NO.16 MANUFACTURER'S STANDARD
5. THICKNESS OF DUCTS SHALL BE AT LEAST
GREASE POCKETS.
1. DESIGN OF VIBRATION ISOLATION CONNECTORS
SHALL BE APPROVED BY THE
2. PROVIDE ADEQUATE CLEANOUT OPENINGS FOR
THOROUGH CLEANING OF DUCT SYSTEM.
3. PROVIDE ADEQUATE MAKEUP AIR FOR
PROPER OPERATION.
4. PROVIDE A SEPARATE DUCT SYSTEM FOR
8. "THERMAL CERAMICS" FIREMASTER DUCTWRAP XL
SHALL BE INSTALLED PER MANUFACTURER'S
EACH HOOD.
BUILDING OFFICIAL. REFER TO 2010 CMC
REFER TO 2010 CMC
REFER TO 2010 CMC
REFER TO 2010 CMC
REQUIREMENTS. DUCTWRAP XL IS ESR-2213
LISTED.
FLOOR
COOKING
EQUIPMENT
48" MAX6" MIN
COOK TOP
ON ALL SIDES
9. HOODS, FILTERS, EXHAUST FANS, AND DUCTS SHALL HAVE A CLEARANCE OFAT LEAST 18" TO COMBUSTIBLE MATERIALS, 3" TO LIMITED COMBUSTIBLEMATERIALS, AND 0" TO NON-COMBUSTIBLE MATERIAL.
80" MAX
30"
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
M1.30
XXXXX
BID & PERMIT
XX-XX-XX
MECHANICALDETAILS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
NOT TO SCALE3
CEILING DIFFUSER DETAILNOT TO SCALE
5DUCT THRU ROOF DETAIL
NOT TO SCALE7
ROOF MOUNTED DUCT SUPPORT DETAIL
NOT TO SCALE9
GREASE DUCT INSULATION DETAILNOT TO SCALE
11GREASE DUCT SUPPORT DETAIL
NOT TO SCALE10
GREASE DUCT NOTESNOT TO SCALE
8INSULATED ACCESS DOOR DETAIL
NOT TO SCALE6
ROOF CURB DETAILNOT TO SCALE
4ROOF PLATFORM DETAIL
NOT TO SCALE2
POWERED ROOF TOP EXHAUST FAN
NOT TO SCALE1
GREASE EXHAUST DUCT REQUIREMENTS HOODS #1, #2, & #3
REVISIONS
NO. DATE DESCRIPTION
PATENT NUMBERS
AC-PSP Wall (Canada) - CA Patent 2820509
AC-PSP (United States) - US Patent 7963830 B2
AC-PSP Island (Canada) - CA Patent 2520330
C US
ww
w.c
apt
ive
aire
.co
m
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION DATE:
AC
CORD
ANC
E
No
. 96B
UIL
T
NF
PA
WITH
IN
S
L
ID
TE
R
HOOD INFORMATION - Job#2979337
1
2
3
P095
P095
P133
4830
ND-2-PSP-FSS
4830
ND-2-PSP-FSS
3347
BD-2-PSP-F
13' 2.00"
13' 2.00"
3' 0.00"
600Deg.
600Deg.
450Deg.
4400
4400
800
14"
14"
9"
28"
28"
8"
4"
4"
4"
4400
4400
800
-0.642"
-0.642"
-0.353"
3960
3960
600
430 SS
Where Exposed
430 SS
Where Exposed
430 SS
Where Exposed
ALONE
ALONE
ALONE
FRONT
BACK
ALONE
HOODNO.
TAG MODEL LENGTHMAX.
COOKINGTEMP.
EXHAUST PLENUM
TOTALEXH. CFM
RISER(S)
WIDTH LENG. HEIGHT DIA. CFM S.P.
TOTALSUPPLY
CFM
HOODCONSTRUCTION
HOOD CONFIG.
END TOEND
ROW
HOOD INFORMATION
1
2
3
P095
P095
P133
SS Baffle with Handles
SS Baffle with Handles
SS Baffle with Handles
9
9
2
20"
20"
16"
16"
16"
16"
30%
30%
30%
4
4
1
L55 Series E26
L55 Series E26
L55 Series E26
NO
NO
NO
YES
YES
YES
716LBS
716LBS
162LBS
HOODNO.
TAG
FILTER(S)
TYPE QTY. HEIGHT LENGTH EFFICIENCY @ 9 MICRONS
LIGHT(S)
QTY. TYPEWIRE
GUARD
UTILITY CABINET(S)
LOCATION SIZE
FIRE SYSTEM
TYPE SIZE
ELECTRICAL
MODEL #
SWITCHES
QUANTITY
FIRESYSTEMPIPING
HOODHANGING
WGHT
HOOD OPTIONS
1
2
3
P095
P095
P133
STRUCTURAL FRONT PANEL
STRUCTURAL FRONT PANEL
RIGHT QUARTER END PANEL 23" Top Width, 0" Bottom Width, 23" High 430 SS
LEFT QUARTER END PANEL 23" Top Width, 0" Bottom Width, 23" High 430 SS
RISER SENSOR INSTALL 6IN PLEN
HOOD NO. TAG OPTION
PERFORATED SUPPLY PLENUM(S)
1
2
3
P095
P095
P133
Front
Left
Right
Front
Left
Right
Front
158"
62"
62"
158"
62"
62"
36"
14"
14"
14"
14"
14"
14"
12"
6"
6"
6"
6"
6"
6"
6"
MUA
MUA
MUA
MUA
MUA
MUA
MUA
MUA
MUA
MUA
MUA
MUA
MUA
MUA
MUA
12"
12"
12"
10"
10"
10"
10"
12"
12"
12"
10"
10"
10"
10"
10"
28"
28"
28"
20"
20"
20"
20"
28"
28"
28"
20"
20"
20"
20"
24"
739
739
739
435
435
435
435
739
739
739
435
435
435
435
600
0.205"
0.205"
0.205"
0.128"
0.128"
0.128"
0.128"
0.205"
0.205"
0.205"
0.128"
0.128"
0.128"
0.128"
0.194"
HOOD NO. TAG POS. LENGTH WIDTH HEIGHT TYPE
RISER(S)
WIDTH LENG. DIA. CFM S.P.
3' 0.00"Nom./3' 0.00"OD
33"
12"
18"
6"
10"
24"
3"
18" 18"
8 1/2"
9"
8"
PLAN VIEW - Hood #3 (P133)3' 0.00" LONG 3347BD-2-PSP-F
U.L. Listed L55 Series E26 Canopy Light Fixture -High Temp Assembly
3" INTERNAL STANDOFF
GREASE DRAINWITH REMOVABLE CUP
SEE HOOD TABLE
§EXHAUST RISER
HANGING ANGLE
L55 SERIES E26 CANOPY LIGHT FIXTURE -HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMALAND SHOCK RESISTANT GLOBE (L55 FIXTURE)
23.5% OPEN STAINLESSSTEEL PERFORATED PANEL
SUPPLY RISER WITHVOLUME DAMPER
6"
4"
12"
48"
FIELD INSTALLEDQUARTER END PANELS
EQUIPMENT BY OTHERS
47.0" MAX
47"
38"
71"
14" NOM.
33"
SECTION VIEW - MODEL 3347BD-2-PSP-F
HOOD - #3 (P133)
IT IS THE RESPONSIBILITY OF THE ARCHITECT/OWNER TO
ENSURE THAT THE HOOD CLEARANCE FROM LIMITED-COMBUSTIBLE
AND COMBUSTIBLE MATERIALS IS IN COMPLIANCE WITH
LOCAL CODE REQUIREMENTS.
16" SS BAFFLE WITHHANDLES AND HOOK
2979337
MASTER DRAWING
AHJ-86
1
4/6/2017
El P
ollo
Loc
o #X
XX
X -
Avo
ndal
e A
Z
3/4" =1'-0"
AV
ON
DA
LE
, A
Z, 85323
Southern C
alifornia
Offic
e
30
02
Do
w A
ve
., S
uite
410
, T
ustin
, C
A, 9
278
0 P
HO
NE
: (7
14
) 9
57
-15
00
FA
X: (9
19
) 2
27
-59
75
EM
AIL
: re
g86
@ca
ptive
aire
.co
m
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
M1.40
XXXXX
BID & PERMIT
XX-XX-XX
HOOD DETAILS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
CAPTIVE-AIRE HOODS AREBUILT IN COMPLIANCE WITH
UL 710 AND NFPA 96AND ARE RECOGNIZED BY
ONEOR MORE OF THE
FOLLOWING:
ETL SANITATION LISTED
ETL LISTED FILE#: 3054804-001
REVISIONS
NO. DATE DESCRIPTION
C US
ww
w.c
apt
ive
aire
.co
m
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION DATE:
AC
CORD
ANC
E
No
. 96B
UIL
T
NF
PA
WITH
IN
S
L
ID
TE
R
13' 2.00"Nom./13' 2.00"OD
48"
14"
26 1/4"
7"
12"
28"
52 3/4"
7"
12"
28"
52 3/4"
7"
12"
28"
14"
15 1/2"
7"
20"
10"31" 7"
20"
10"
14"
15 1/2"
7"
20"
10"
31"
7"
20"
10"
3"
79" 79"
11"
14"
28"
PLAN VIEW - Hood #1 (P095)13' 2.00" LONG 4830ND-2-PSP-FSS
NOTE: Additional hanging angles provided for hoods 12' and longer.
U.L. Listed L55 Series E26 Canopy Light Fixture -High Temp Assembly
13' 2.00"Nom./13' 2.00"OD
48"
14"
26 1/4"
7"
12"
28"
52 3/4"
7"
12"
28"
52 3/4"
7"
12"
28"
14"
15 1/2"7"
20"
10"31"7"
20"
10"
14"
15 1/2"
7"
20"
10"
31"
7"
20"
10"
3"
79"79"
11"
14"
28"
PLAN VIEW - Hood #2 (P095)13' 2.00" LONG 4830ND-2-PSP-FSS
NOTE: Additional hanging angles provided for hoods 12' and longer.
U.L. Listed L55 Series E26 Canopy Light Fixture -High Temp Assembly
SEE HOOD TABLE
§
L55 SERIES E26 CANOPY LIGHT FIXTURE -HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMALAND SHOCK RESISTANT GLOBE (L55 FIXTURE)
23.5% OPEN STAINLESSSTEEL PERFORATED PANEL
ATTACHING PLATES
SUPPLY RISER WITHVOLUME DAMPER
6"
4"
14"
24"
EQUIPMENT BY OTHERS
48.0" MAX
80"
30" NOM.
48"
SECTION VIEW - MODEL 4830ND-2-PSP-FSS
HOOD - #1 (P095)
SEE HOOD TABLE
§
L55 SERIES E26 CANOPY LIGHT FIXTURE -HIGH TEMP ASSEMBLY, INCLUDES CLEAR THERMAL
AND SHOCK RESISTANT GLOBE (L55 FIXTURE)
23.5% OPEN STAINLESSSTEEL PERFORATED PANEL
ATTACHING PLATES
SUPPLY RISER WITHVOLUME DAMPER
6"
4"
14"
24"
EQUIPMENT BY OTHERS
48.0" MAX
80"
30" NOM.
48"
SECTION VIEW - MODEL 4830ND-2-PSP-FSS
HOOD - #2 (P095)
2979337
MASTER DRAWING
AHJ-86
2
4/6/2017
El P
ollo
Loc
o #X
XX
X -
Avo
ndal
e A
Z
3/4" =1'-0"
AV
ON
DA
LE
, A
Z, 85323
Southern C
alifornia
Offic
e
30
02
Do
w A
ve
., S
uite
410
, T
ustin
, C
A, 9
278
0 P
HO
NE
: (7
14
) 9
57
-15
00
FA
X: (9
19
) 2
27
-59
75
EM
AIL
: re
g86
@ca
ptive
aire
.co
m
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
M1.41
XXXXX
BID & PERMIT
XX-XX-XX
HOOD DETAILS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
CAPTIVE-AIRE HOODS AREBUILT IN COMPLIANCE WITH
UL 710 AND NFPA 96AND ARE RECOGNIZED BY
ONEOR MORE OF THE
FOLLOWING:
ETL SANITATION LISTED
ETL LISTED FILE#: 3054804-001
REVISIONS
NO. DATE DESCRIPTION
- HIGH HEAT OPERATION BELT DRIVE 500°F (260°C)
AT 600°F (316°C) FOR A PERIOD OF
DAMAGED TO ANY EXTENT THAT COULD CAUSE
15 MINUTES WITHOUT THE FAN BECOMING
WHILE EXHAUSTING BURNING GREASE VAPORS
EXHAUST FAN MUST OPERATE CONTINUOUSLY
- TILT OUT WHEEL
ABNORMAL FLARE-UP TEST BELT & DIRECT DRIVE
AN UNSAFE CONDITION.
- UL762
- ROOF MOUNTED FANS
- RESTAURANT MODEL
FEATURES:
- GREASE CLASSIFICATION TESTING
- LOCKING PIN FOR POWER PACK
- MOTOR WEATHER COVER
- HIGH HEAT OPERATION DIRECT DRIVE 300°F (149°C)
- HEAT SLINGER
23 7/8
28
31 1/2
33
73
28 7/8
36
2" DRAIN
20"
51 3/8
19
42 3/8
25 1/2
14 3/4
19
LOCK & SPRING PIN
65°
6 1/4"
- INTERLOCKED DISCONNECT SWITCH
DETERIORATING EFFECTS TO THE FAN WHICH
THERMAL EQUILIBRIUM, AND WITHOUT ANY
UNTIL ALL FAN PARTS HAVE REACHED
WHILE EXHAUSTING AIR AT 500°F (260°C)
EXHAUST FAN MUST OPERATE CONTINUOUSLY
WOULD CAUSE UNSAFE OPERATION.
NORMAL TEMPERATURE TEST BELT DRIVE
DUCTWORK BETWEEN
AND FAN (BY OTHERS)
EXHAUST RISER ON HOOD
3" FLANGE
2828
ROOF OPENING
DIMENSIONS
20 GAUGE
CONSTRUCTIONSTEEL
20"
31 1/2"
31 1/2"
VENTED
CURB
EXAMPLE: 7/12 PITCH = 30° SLOPE
PITCHED CURBS ARE AVAILABLE
FOR PITCHED ROOFS.
SPECIFY PITCH:
0"
0°
12"
FANS #1 (P095), #2 (P095) - CASRE24BD EXHAUST FAN
OPTIONS
UTILITY SET GREASE CUP
- WEATHERPROOF DISCONNECT
- GREASE CLASSIFICATION TESTING
- HIGH HEAT OPERATION 300°F (149°C)
DAMAGED TO ANY EXTENT THAT COULD CAUSE
15 MINUTES WITHOUT THE FAN BECOMING
AT 600°F (316°C) FOR A PERIOD OF
WHILE EXHAUSTING BURNING GREASE VAPORS
EXHAUST FAN MUST OPERATE CONTINUOUSLY
ABNORMAL FLARE-UP TEST
WOULD CAUSE UNSAFE OPERATION.
DETERIORATING EFFECTS TO THE FAN WHICH
THERMAL EQUILIBRIUM, AND WITHOUT ANY
UNTIL ALL FAN PARTS HAVE REACHED
WHILE EXHAUSTING AIR AT 300°F (149°C)
EXHAUST FAN MUST OPERATE CONTINUOUSLY
NORMAL TEMPERATURE TEST
- AMCA SOUND AND AIR CERTIFIED
- WIRING FROM MOTOR TO DISCONNECT SWITCH
21
17 1/2
12 1/8
27 1/4
25 1/4
2
18 1/2
AN UNSAFE CONDITION.
FEATURES:
- RESTAURANT MODEL
- ROOF MOUNTED FANS
- UL705 AND UL762
DUCTWORK BETWEENEXHAUST RISER ON HOODAND FAN (BY OTHERS)
GREASE DRAIN
3" FLANGE
17 1/217 1/2
ROOF OPENING
DIMENSIONS
20 GAUGE
CONSTRUCTIONSTEEL
22"
19 1/2"
19 1/2"
VENTED
CURB
FAN #3 NCA8FA - EXHAUST FAN (P133)
OPTIONS
GREASE BOX
C US
ww
w.c
apt
ive
aire
.co
m
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION DATE:
AC
CORD
ANC
E
No
. 96B
UIL
T
NF
PA
WITH
IN
S
L
ID
TE
R
EXHAUST FAN INFORMATION - Job#2979337
1
2
3
P095
P095
P133
CASRE24BD
CASRE24BD
NCA8FA
4400
4400
800
1.200
1.200
1.250
1043
1043
1691
5.000
5.000
0.500
2.6050
2.6050
0.3790
3
3
3
208
208
208
15.0
15.0
1.9
1494 FPM
1494 FPM
455
455
96
22
22
11.9
FANUNITNO.
TAG FAN UNIT MODEL # CFM ESP. RPM H.P. B.H.P. ∅ VOLT FLADISCHARGEVELOCITY
WEIGHT(LBS.)
SONES
MUA FAN INFORMATION - Job#2979337
4 PALL A4-920 920 A4 8520 0.750 587 5.000 3.0610 3 208 15.0 100.0°F 65.0°F 79.0°F 65.0°F 1421 24
FANUNITNO.
TAG FAN UNIT MODEL # BLOWER HOUSINGDESIGN
CFMESP. RPM H.P. B.H.P. ∅ VOLT FLA
EVAP COOLERENTERING DB
TEMP.
EVAP COOLERENTERING WB
TEMP.
EVAP COOLERLEAVING DB
TEMP.
EVAP COOLERLEAVING WB
TEMP.
WEIGHT(LBS.)
SONES
FAN OPTIONS
1
2
3
4
P095
P095
P133
PALL
1 - Utility Set Grease Cup
1 - Utility Set Grease Cup
1 - Grease Box
1 - Evaporative Cooler Wiring Harness
1 - Separate 120V Wiring Package (Required and used only for DCV or Prewirewith VFD) - Three Phase Only
FANUNITNO.
TAG OPTION (Qty. - Descr.)
FAN ACCESSORIES
1
2
3
4
P095
P095
P133
PALL
YES
YES
YES
FANUNITNO.
TAG
EXHAUST
GREASE CUPGRAVITYDAMPER
WALLMOUNT
SUPPLY
SIDEDISCHARGE
GRAVITYDAMPER
MOTORIZED DAMPERWALL
MOUNT
CURB ASSEMBLIES
1
2
3
4
# 1
# 2
# 3
# 4
# 4
43 LBS
43 LBS
30 LBS
40 LBS
Curb
Curb
Curb
Curb
Rail
31.500"W x 31.500"L x 20.000"H Vented
31.500"W x 31.500"L x 20.000"H Vented
19.500"W x 19.500"L x 22.000"H Vented Hinged
42.000"W x 42.000"L x 12.000"H
4.000"W x 4.000"L x 36.000"H
NO.ONFAN
WEIGHT ITEM SIZE
2979337
MASTER DRAWING
AHJ-86
3
4/6/2017
El P
ollo
Loc
o #X
XX
X -
Avo
ndal
e A
Z
3/4" =1'-0"
AV
ON
DA
LE
, A
Z, 85323
Southern C
alifornia
Offic
e
30
02
Do
w A
ve
., S
uite
410
, T
ustin
, C
A, 9
278
0 P
HO
NE
: (7
14
) 9
57
-15
00
FA
X: (9
19
) 2
27
-59
75
EM
AIL
: re
g86
@ca
ptive
aire
.co
m
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
M1.42
XXXXX
BID & PERMIT
XX-XX-XX
HOOD DETAILS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
CAPTIVE-AIRE HOODS AREBUILT IN COMPLIANCE WITH
UL 710 AND NFPA 96AND ARE RECOGNIZED BY
ONEOR MORE OF THE
FOLLOWING:
ETL SANITATION LISTED
ETL LISTED FILE#: 3054804-001
REVISIONS
NO. DATE DESCRIPTION
FLEX CONDUITFOR FIELD
WIRING
8 9/16"
24 7/8"
24 7/8"
BLOWER DISCHARGE
1 1/8"
CURB
LIFTING LUG
5 1/4"
AIRFLOW
BLOWER/MOTORACCESS DOOR24" SERVICECLEARANCE REQ.
SERVICEDISCONNECT
SWITCH
AIRFLOW
28 7/8"
4 1/2"
5 3/4"
17 1/2"
∅1 1/2"WATERDRAIN
AIRFLOW
∅1/2" NPTWATER INLET
FILTER/CONTROLACCESS DOOR
LPD CELDEK
AIRFLOW
48 7/16"
6 3/4"
42"
12" EQUIPMENT CURB
64 3/16"
51 3/8"
42"
35 1/4"
58 3/8"
58 5/8"
ADJUSTABLELEG
99 7/16"
170 13/16"
FAN #4 A4-920 - SUPPLY FAN (PALL)1. UNTEMPERED SUPPLY UNIT WITH 20" BLOWER IN SIZE #4 HOUSING2. EVAP COOLER (LPD CELDEK) – W/INTAKE HOOD W/EZ FILTERS3. DOWN DISCHARGE - AIR FLOW RIGHT -> LEFT4. 120V WIRING CONNECTION TO ENERGIZE EVAPORATIVE COOLERS FROM UNTEMPERED SUPPLY FANS.5. SEPARATE 120VAC WIRING PACKAGE FOR MAKE-UP AIR UNITS. OPTION MUST BE SELECTED WHEN MOUNTING VFD IN PREWIRE PANEL OR WITH DCVPACKAGE. PROVIDES SEPARATE 120VAC INPUT TO SUPPLY FAN. THIS 120V SIGNAL MUST BE RUN BY ELECTRICIAN FROM DCV TO MUA SWITCH.
L ETS DI
R
ROOF OPENING 2" SMALLER THAN CURB DIMENSION.
EXAMPLE: 7/12 PITCH = 30° SLOPE
PITCHED CURBS ARE AVAILABLE
FOR PITCHED ROOFS.
SPECIFY PITCH:
0"
0°
12"
C US
ww
w.c
apt
ive
aire
.co
m
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION DATE:
AC
CORD
ANC
E
No
. 96
BU
ILT
NF
PA
WITH
IN
S
L
ID
TE
R
2979337
MASTER DRAWING
AHJ-86
4
4/6/2017
El P
ollo
Loc
o #X
XX
X -
Avo
ndal
e A
Z
3/4" =1'-0"
AV
ON
DA
LE
, A
Z, 85323
Southern C
alifornia
Offic
e
30
02
Do
w A
ve
., S
uite
410
, T
ustin
, C
A, 9
278
0 P
HO
NE
: (7
14
) 9
57
-15
00
FA
X: (9
19
) 2
27
-59
75
EM
AIL
: re
g86
@ca
ptive
aire
.co
m
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
M1.43
XXXXX
BID & PERMIT
XX-XX-XX
HOOD DETAILS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
CAPTIVE-AIRE HOODS AREBUILT IN COMPLIANCE WITH
UL 710 AND NFPA 96AND ARE RECOGNIZED BY
ONEOR MORE OF THE
FOLLOWING:
ETL SANITATION LISTED
ETL LISTED FILE#: 3054804-001
REVISIONS
NO. DATE DESCRIPTION
C US
ww
w.c
apt
ive
aire
.co
m
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION DATE:
AC
CORD
ANC
E
No
. 96B
UIL
T
NF
PA
WITH
IN
S
L
ID
TE
RJOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
BREAKER 1PH
CONTROL POWER. DO NOT WIRE
TO SHUNT TRIP BREAKER.
1ST HOOD LIGHT BREAKER SHARED W/ CONTROLPOWER. SWITCH #1
WIRE TO VFD QUICK CONNECTOR
BREAKER 3PH
MCA:
MOCP:
WIRE TO VFD QUICK CONNECTOR
BREAKER 3PH
MCA:
MOCP:
WIRE TO VFD QUICK CONNECTOR
BREAKER 3PH
MCA:
MOCP:
BREAKER 3PH
WIRE TO VFD QUICK CONNECTOR
MCA:
MOCP:
Load Wiring
WIRE TO
VFD QUICK
WIRE TO
DISCONNECT
CONNECTOR
MUST HAVE ITS OWN CONDUIT
DO NOT SHARE CONDUIT!
FLA:
HP:
VOLT:
Load Wiring
WIRE TO
VFD QUICK
WIRE TO
DISCONNECT
CONNECTOR
MUST HAVE ITS OWN CONDUIT
DO NOT SHARE CONDUIT!
FLA:
HP:
VOLT:
Load Wiring
WIRE TO
VFD QUICK
WIRE TO
DISCONNECT
CONNECTOR
MUST HAVE ITS OWN CONDUIT
DO NOT SHARE CONDUIT!
FLA:
HP:
VOLT:
Load WiringBLACK
BLACK
BLACK
GREEN
WIRE TO
VFD QUICK
CONNECTORWHITE
RED
FLA:
HP:
VOLT:
MUST HAVE ITS OWN CONDUIT
DO NOT SHARE CONDUIT!
MAKE UP AIR
PROVING
INTERLOCK
DAMPER
LOW VOLTAGE CONNECTION FOR
DAMPER INTERLOCK. SHOULD
HAVE CONTINUITY WHEN DAMPER
IS PROVEN OPEN.
IN MUA #1
TERMINAL NAMES
DO NOT APPLY
IF MUA BY OTHERS
ON PCB
REMOVE JUMPER
NOT REQUIRED FOR ALL UNITS.
SEE MAKE-UP AIR SCHEMATIC.
WIRE C1 TO COMMON (1).
C1 TO AR1 SHOULD HAVE
CONTROL PANEL
FIRE SYSTEM
TO
MICROSWITCH
CONTINUITY WHEN ARMED.
IF MORE THAN ONE
WIRE AR1 TO NORMALLY CLOSED (2).
CAP
OFF
CAP
OFF
CAP
OFFFIRE SYSTEM, WIRE
IN SERIES AS SHOWN
WIRE DIRECTLY TO CONTROL BOARD
CAT-5 CONNECTION
CONTROL PANEL
REMOTE
TO
MOUNTED
SWITCHES
PLACE END OF LINE PLUG
EOL120AIN EMPTY JACK. PN: EOL120A
HMI
CONTROL PANEL
HOOD LIGHTS
TO
1400 W MAXWIRE TO J-BOX ON TOP OF HOOD
WIRE DIRECTLY TO COMMUNICATION
CONTROL PANEL
WORLD WIDE
TO
WEB
ROUTER
COMM
MODULE. SEE CASLINK OWNERS
MANUAL FOR FURTHER INSTRUCTIONS.
CAT-5 ETHERNET CONNECTION
WIRE TO CONTROL BOARD.
SENSOR MOUNTED IN ROOM AWAY
FROM HEAT SOURCES. SEE MANUAL
CONTROL PANEL
KITCHEN TEMP
TO
SENSOR
WIRE TO CONTROL BOARD.
SENSOR MOUNTED IN EXHAUST DUCT
CONTROL PANEL
DUCT SENSOR
TO
WIRE TO CONTROL BOARD.
SENSOR MOUNTED IN EXHAUST DUCT
CONTROL PANEL
DUCT SENSOR
TO
WIRE TO CONTROL BOARD.
SENSOR MOUNTED IN EXHAUST DUCT
CONTROL PANEL
DUCT SENSOR
TO
WIRE TO CONTROL BOARD.
SENSOR MOUNTED IN SUPPLY PLENUM.
CONTROL PANEL
PSP SENSOR
TO
THE FOLLOWING CONNECTIONS
MAY OR MAY NOT BE
REQUIRED BASED ON JOBSITE
SPECIFICATIONS
CONTROL PANEL
EXTERNAL
SIGNAL FOR
SHUNT TRIP
ST TERMINAL IS ENERGIZED
IN FIRE CONDITION.
SYSTEM DRY
SPARE FIRE
CONTACT
CONTROL PANEL
SPARE CONTACTS WILL MAKE C2 TO
AR2 WHEN SYSTEM IS ARMED. THEY
ARE USED TO DISABLE EQUIPMENT
OR PROVIDE SIGNALS. (NOT FOR
BUILDING FIRE ALARM WHICH MUST
BE WIRED DIRECTL TO THE ANSUL
ALARM INITIATING SWITCH LOCATED
IN ANSUL AUTOMAN)
SPARE CONTACTS WILL MAKE
CONTROL PANEL
ON/OFF WITH
DRY CONTACT
SUPPLY FAN
COMMON TO NORMALLY OPEN
WHEN SUPPLY FAN IS ON.
GROUP 1
WIRE TO ECPM03 TERMINALS.
CONFIGURABLE OUTPUT.
DCV SPEED
(TOTAL)
0-10V OUTPUT
ON PCB
SEE ECPM03 OWNERS MANUAL.
TO BMS
+
-
WIRE TO VFD TERMINAL STRIP.
PROPORTIONAL TO FREQUENCY.
VFD ANALOG
(EACH VFD)
0-10V OUTPUT
IN VFD
SEE VFD OWNERS MANUAL.
TO BMS
+
-
Hot
NeutralH1N1
120 V
15 A
Ground GND
LINE
LINE
Ground
P095 SM-1GND
L1L2
LINE L3208 V
18.8 A
30 A
LINE
LINE
Ground
P095 SM-2GND
L4L5
LINE L6208 V
18.8 A
30 A
LINE
LINE
Ground
P133 SM-3GND
L7L8
LINE L9208 V
2.4 A
15 A
LINE
LINE
208 V
Ground
PALL SM-4GND
L10L11
LINE L1218.8 A
30 A
P09501LOAD LEG 1
LOAD LEG 2
GND GROUND
FAN:
SM-1LOAD LEG 3
U1V1W1
15.0
5.000
208 V
P09502LOAD LEG 1
LOAD LEG 2
GND GROUND
FAN:
SM-2LOAD LEG 3
U2V2W2
15.0
5.000
208 V
P13303LOAD LEG 1
LOAD LEG 2
GND GROUND
FAN:
SM-3LOAD LEG 3
U3V3W3
1.9
0.500
208 V
U4V4W4
LOAD LEG 1
LOAD LEG 2
LOAD LEG 3
GND GROUND
PALL04FAN:
SM-4
N1 120V NEUTRAL
120V HOT
N1
15.0
5.000
208 V
IL1AIL1B
D3D7
C1AR1
MICROSWITCH 1
1:C
4:NO
2:NC
MS-1
1:C
4:NO
2:NC
1:C
4:NO
2:NC
MS-2
C1
AR1
J4 1
2
B1W1
GND
HOOD LIGHTS 1
- -
T1AT1B
ROOM TEMP
T2AT2B HOOD 1
RISER 1
T3AT3B HOOD 2
RISER 1
T4AT4B HOOD 3
RISER 1
T5AT5B HOOD 1
PSP TEMP
STN1
NEUTRAL FROM SHUNT COIL
HOT TO SHUNT COILSHUNT COIL
C2AR2
COMMON
NORMALLY OPEN
SFC1SFO1
COMMON
NORMALLY OPEN
SFC2SFO2
COMMON
NORMALLY OPEN
VO+VO-
302
BREAKER PANEL CONTROL PANEL
CONTROL PANEL FANS
CONTROL PANEL COMPONENT
BREAKER PANEL TO CONTROL PANEL
Responsibility: ElectricianBREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED
CONTROL PANEL TO FANS
Responsibility: Electrician
CONTROL PANEL TO ACCESSORY ITEMS
Responsibility: Electrician
2979337El Pollo Loco #XXXX - Avondal...
DCV-3111
2979337
MASTER DRAWING
AHJ-86
5
4/6/2017
El P
ollo
Loc
o #X
XX
X -
Avo
ndal
e A
Z
3/4" =1'-0"
AV
ON
DA
LE
, A
Z, 85323
Southern C
alifornia
Offic
e
30
02
Do
w A
ve
., S
uite
410
, T
ustin
, C
A, 9
278
0 P
HO
NE
: (7
14
) 9
57
-15
00
FA
X: (9
19
) 2
27
-59
75
EM
AIL
: re
g86
@ca
ptive
aire
.co
m
ELECTRICAL PACKAGES - Job#2979337
1 DCV-3111 Wall Mount In SS Box08 - Ship Loose
w/ Prewire
1 Light
1 Fan
Smart Controls DCV
P095
P095
P133
PALL
Exhaust
Exhaust
Exhaust
Supply
3
3
3
3
5.000
5.000
0.500
5.000
208
208
208
208
15.0
15.0
1.9
15.0
NO. TAGPACKAGE
#LOCATION
SWITCHES
LOCATION QUANTITY
OPTIONFANS CONTROLLED
FAN TAG TYPE ɸ H.P. VOLT FLA
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
4/6/2017
INSTALL
ECP #1-1
Demand Control Ventilation, w/ control for 3 Exhaust Fans, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fans
modulate based on duct temperature. INVERTER DUTY THREE PHASE MOTOR REQUIRED! Room temperature sensor shipped
loose for field installation.Verify distance between VFD and Motor; additional cost could apply if distance exceeds
50 feet.
SF1
BLACK
WHITE
GREEN
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
M1.44
XXXXX
BID & PERMIT
XX-XX-XX
HOOD DETAILS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
CAPTIVE-AIRE HOODS AREBUILT IN COMPLIANCE WITH
UL 710 AND NFPA 96AND ARE RECOGNIZED BY
ONEOR MORE OF THE
FOLLOWING:
ETL SANITATION LISTED
ETL LISTED FILE#: 3054804-001
REVISIONS
NO. DATE DESCRIPTION
C US
ww
w.c
apt
ive
aire
.co
m
SHEET NO.
SCALE:
DWG.#:
DRAWN
DATE:
BY:
REVISIONS
DESCRIPTION DATE:
AC
CORD
ANC
E
No
. 96B
UIL
T
NF
PA
WITH
IN
S
L
ID
TE
R
JOB NO
JOB NAME
MODEL NUMBER
DATE
DRAWN BY
DWG NO
SCHEMATIC TYPE
CONTROL PANEL
EXTERNAL
TO
SWITCH
SIGNAL SWITCH THROUGH BMS
WILL ACTIVATE ZONE1 FANS AND
LIGHTS
H1IO1
BMS SWITCHC NO
2979337El Pollo Loco #XXXX - Avondal...
DCV-3111
2979337
MASTER DRAWING
AHJ-86
6
4/6/2017
El P
ollo
Loc
o #X
XX
X -
Avo
ndal
e A
Z
3/4" =1'-0"
AV
ON
DA
LE
, A
Z, 85323
Southern C
alifornia
Offic
e
30
02
Do
w A
ve
., S
uite
410
, T
ustin
, C
A, 9
278
0 P
HO
NE
: (7
14
) 9
57
-15
00
FA
X: (9
19
) 2
27
-59
75
EM
AIL
: re
g86
@ca
ptive
aire
.co
m
DESCRIPTION OF OPERATION:
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
4/6/2017
INSTALL
ECP #1-2
Demand Control Ventilation, w/ control for 3 Exhaust Fans, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Fans
modulate based on duct temperature. INVERTER DUTY THREE PHASE MOTOR REQUIRED! Room temperature sensor shipped
loose for field installation.Verify distance between VFD and Motor; additional cost could apply if distance exceeds
50 feet.
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
M1.45
XXXXX
BID & PERMIT
XX-XX-XX
HOOD DETAILS
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
CAPTIVE-AIRE HOODS AREBUILT IN COMPLIANCE WITH
UL 710 AND NFPA 96AND ARE RECOGNIZED BY
ONEOR MORE OF THE
FOLLOWING:
ETL SANITATION LISTED
ETL LISTED FILE#: 3054804-001
REVISIONS
NO. DATE DESCRIPTION
W/H
S2442
F
S2424
S2448
S2448
S2448
2436
G
A-0
03
9
24'
20'
CW
MG
GCO
GI
GCO
GCOGCO2"
(1,500 GAL.)
SAMPLING PORT PER LOCAL JURISDICTION AUTHORITY
6" SANITARY SEWER, FOR CONTINUATION REFER TO CIVIL PLANS
2" DOMESTIC WATER, FOR CONTIUATION REFER TO CIVIL PLANS
PROPOSED GAS METER LOCATION.
V
V
3"
3"
4"4"
4"4"
GCO4"
4"6"
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
P0.10
XXXXX
BID & PERMIT
XX-XX-XX
SITE PLAN -PLUMBING
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/16" = 1'-0"1
SITE PLAN - PLUMBING
REVISIONS
NO. DATE DESCRIPTION
PLUMBING NOTES1. BEFORE COMMENCEMENT OF WORK, THE CONTRACTOR SHALL VERIFY EXACT LOCATIONS, ELEVATIONS
AND CHARACTERISTICS OF UTILITIES AND PIPING AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
2. EXACT LOCATION AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BE OBTAINED FROM ARCHITECTURAL AND FOOD SERVICE DRAWINGS.
3. THE CONTRACTOR SHALL MAKE ALL ARRANGEMENTS WITH UTILITY COMPANIES FOR SERVICE AND CONNECTIONS AND SHALL PAY ALL FEES, CHARGES, PERMITS, INCLUDING COST OF VAULTS AND METERS.
4. ALL VENT AND FLUE OUTLETS SHALL BE 10'-0" MINIMUM FROM ANY FRESH AIR INTAKES OR TERMINATE 3'-0" ABOVE ANY FRESH AIR INTAKE.
5. THE CONTRACTOR SHALL PROVIDE: ALL FAUCETS, TRAPS, TRAP PRIMERS, STOPS, GATE VALVES, GAS COCKS, BACKFLOW PREVENTION DEVICE WATER HAMMER ARRESTORS, CLEANOUT COVERS AND INDIRECT WASTE TO AN APPROVED RECEPTOR.
6. INSTALL ALL PLUMBING TO AVOID INTERFERENCE WITH ELECTRICAL AND MECHANICAL EQUIPMENT AND FRAMING.
7. THE CONTRACTOR SHALL RECORD ON AS-BUILT DRAWINGS ALL SIZES, LOCATIONS, AND MATERIALS OF EXISTING PIPING ENCOUNTERED DURING EXCAVATION AND NEW PIPING INSTALLED.
8. ALL LAVATORY AND SINK FAUCETS SHALL BE CERTIFIED REQUIRING FLOW CONTROL OF 2.2 GPM.
9. CONTRACTOR SHALL LABEL ALL ACCESSIBLE GAS & WATER SHUT-OFFS.
10. SEE KITCHEN EQUIPMENT DRAWINGS FOR THE EXACT LOCATIONS AND ROUGH-IN.
11. REFER TO ARCHITECTURAL FLOOR PLANS FOR EXACT LOCATIONS OF PLUMBING FIXTURES.
12. PLUMBING CONTRACTOR SHALL COORDINATE EXACT LOCATION OF PLUMBING ROUGH-IN.
13. PLUMBING CONTRACTOR SHALL COORDINATE SITE UTILITIES WITH ARCHITECT AND CIVIL ENGINEER.
14. ALL WORK SHALL BE DONE IN ACCORDANCE WITH ALL LOCAL CODES, RULES AND WITH KITCHEN DRAWINGS AND ADJUST ROUTING OF PIPING IF NECESSARY. REGULATIONS.
15. UPON COMPLETION OF JOB, THIS CONTRACTOR SHALL INSPECT ALL EXPOSED PORTIONS OF THE PLUMBING INSTALLATION AND COMPLETELY REMOVE ALL EXPOSED LABELS, SOIL, MARKINGS, AND FOREIGN MATERIAL EXCEPT PRODUCT LABELS AND THOSE REQUIRED BY LAW.
16. "ALL BURRED ENDS OF ALL (POTABLE WATER) PIPING AND TUBING SHALL BE REAMED TO THE FULL BORE OF THE PIPE OR TUBE AND ALL CHIPS SHALL BE REMOVED (SEE 2006 UNIFORM PLUMBING CODE SECTION 310).
17. INSULATE CONDENSATE DRAIN LINES BELOW ROOF FROM A/C EQUIPMENT WITH 1/2" MINIMUM UNICELLULAR FOAM TO PREVENT CONDENSATE DRIP.
18. WATER PIPING: BELOW GRADE OUTSIDE BUILDING SHALL BE TYPE "K", HARD DRAWN COPPER TUBING WITH SILVER SOLDER JOINT FITTINGS. PIPING ABOVE SLAB SHALL BE TYPE "L", HARD DRAWN COPPER TUBING WITH 2% LEAD SOLDER JOINT FITTINGS. SHOULD STREET PRESSURE EXCEED 80 PSI, A PRESSURE REDUCING VALVE ASSEMBLY SHALL BE INSTALLED. NO JOINTS SHALL BE ALLOWED UNDER BUILDING SLAB. GATE VALVES SHALL BE BRONZE WITH ENDS TO SUITE PIPE, NON- RISING STEM FOR 150 PSI WORKING PRESSURE. INSULATE HOT WATER LINES WITH 1" THICK UNICELLULAR FOAM AND WEATHER JACKET WHERE REQUIRED. CONTRACTOR OPTION TO PROVIDE PEX PIPING AS APPROVED BY LOCAL AUTHORITIES HAVING JURISDICTION.
19. INDIRECT AND CONDENSATE DRAIN PIPING: SHALL BE COPPER, TYPE "M" WITH 95-5 SILVER SOLDER JOINT FITTINGS.
20. STORM DRAIN PIPING: PLACED WITHIN THE INTERIOR OF THE BUILDING SHALL BE GALVANIZED STEEL, CAST IRON, PVC (AS APPROVED BY LOCAL AUTHORITIES) OR OTHER APPROVED PIPING MATERIAL , LOCATED UNDERGROUND SHALL BE CAST IRON SCHEDULED 40, ABS, PVC OR OTHER APPROVED MATERIALS.
21. INSULATION: ALL HOT AND COLD WATER PIPING AND TEMPERED WATER PIPING SHALL BE INSULATED:AIR CONDITIONER CONDENSATE :AIR CONDITIONER CONDENSATE DRAIN LINES SHALL BE INSULATED WITH MANVILLE "AEROTUBE" FOAM PLASTIC PIPE INSULATION.
22. WATER HAMMER ARRESTORS: SHALL BE ALL STAINLESS STEEL CONSTRUCTION, BELLOWS-TYPE "PDI" APPROVED AND CERTIFIED SIZING AND PLACEMENT CONFIRMING TO PLUMBING AND DRAINAGE INSTITUTE STANDARD "PDI-WH 201" LATEST EDITION AND AS MANUFACTURED BY J.R. SMITH, ZERN, OR PPP INC.
23. CLEANOUTS: SHALL BE MANUFACTURED BY J.R. SMITH, ZERN, JOSAM OR FP & M AS FOLLOWS:
A. FINISHED ROOM FLOORS: J.R. SMITH 4163 W/ N.B. TOP GASKETED WATERTIGHT COVER. B. WALLS: J.R. SMITH 4532 W/ BRONZE PLUG AND CHROME PLATED COVER. C. YARD AND PARKING LOT: J.R. SMITH 4253 CAST IRON SURFACE LEVEL CLEANOUT.
24. GAS PIPING: SHALL BE SCHEDULE 40 BLACK STEEL PIPE CONFORMING TO ASTM A53 GRADE A AND B, WITH 150 LB. BLACK MALLEABLE IRON SCREWED FITTINGS AND COUPLINGS. GAS VALVES 1" AND SMALLER SHALL BE LEVER HANDLE TYPE WITH CHECK, ALL BRONZE SCREWED, "CRANE NO. 298" OR EQUAL. 1-1/4" AND LARGER VALVES SHALL BE IRON BODY WITH BRONZE SQUARE HEAD PLUG, "CRANE NO. 324 " OR EQUAL. PROVIDE OPERATING WRENCH WHERE REQUIRED FOR EACH VALVE. PROVIDE APPROVED GAS PRESSURE REGULATORS. NATURAL GAS RIGHT AND LEFT HAND NIPPLES AND COUPLINGS SHALL BE NEW BLACK IRON. UNIONS SHALL NOT BE USED EXCEPT AT UNITS AND VALVES.
25. SOIL WASTE AND VENT PIPING: ALL WASTE & VENT PIPING IS TO BE CAST IRON. NON-METALLIC PIPE ONLY AS PERMITTED BY LOCAL AUTHORITIES (OR SOILS ENGINEERS FOR BELOW GROUND PIPING). ALL PIPING IN METAL STUD COOK LINE WALLS SHALL BE METALLIC PIPING. NO EXCEPTION.
26. PENETRATIONS THROUGH FIRE RESISTIVE ASSEMBLIES SHALL BE SEALED WITH APPROVED/LISTED MATERIALS.
1. ALL REQUIRED CLEANOUTS SHALL BE INSTALLED AS PER SEC. 707.0 & 719.0 OF THE PLUMBING CODE.2. EACH PLUMBING VENT SHALL TERMINATE NOT LESS THAN TEN (10) FEET FROM OR AT LEAST THREE (3)
FEET ABOVE ANY WINDOW, DOOR, OPENING, AIR INTAKE OR VENT SHAFT. 3. NEW OR REPAIRED POTABLE WATER SYSTEMS SHALL BE DISINFECTED PRIOR TO USE ACCORDING TO
THE METHOD SET IN SECTION 609.9 OF THE PLUMBING CODE. 4. EACH VENT SHALL RISE VERTICALLY TO A POINT NOT LESS THAN SIX (6) INCHES IN HEIGHT ABOVE THE
FLOOD LEVEL RIM OF THE FIXTURE BEFORE BEING CONNECTED TO ANY OTHER VENT. 5. MINIMUM SIZE SCREEN PERMITTED ON COMBUSTION AIR DUCT IS ONE-FOURTH (1/4) INCH.
D
PROVIDE CLEANOUTS IN TURNS/END OF PIPE. USE DWV FITTINGS IF SIZE IS LARGER THAN 1".
DISCHARGE INTO CENTER HOLE OF GRATE OF FLOOR SINK WITH AIR GAP SUFFICIENT TO REMOVE GRATE AND STRAINER. MINIMUM GAP = TWICE PIPE DIAMETER.
SLOPE PIPE AS MUCH AS POSSIBLE TOWARD DISCHARGE.
MAKE CONNECTION TO EQUIPMENT AS REQUIRED.
MAKE PIPE MINIMUM ONE SIZE LARGER THAN EQUIPMENT CONNECTION, MINIMUM 3/4". USE "M" OR "L" HARD COPPER UP TO 1" AND TYPE DWV FOR LARGER.
ROUTE PIPE INCONSPICUOUSLY AND UNOBTRUSIVELY. HANG PIPE AS REQUIRED. DO NOT INSULATE INDIRECT DRAIN PIPE WHEN INSTALLED IN FOOD SERVICE FACILITY. REFER TO LOCAL CODES FOR FURTHER INFORMATION.
PLUMBING SYMBOLS
CONNECT TO EXISTING.
EXISTING PIPING TO REMAIN.
PREFIX FOR EXISTING PIPING.
SOIL AND WASTE PIPING.
GREASE WASTE PIPING.
VENT PIPING.
DOMESTIC COLD WATER PIPING.
DOMESTIC HOT WATER PIPING.
DOMESTIC FILTERED COLD WATER PIPING.
DOMESTIC HOT WATER RETURN PIPING.
NATURAL GAS CUT-OFF VALVE.
NATURAL GAS SOLENOID VALVE.
CUT-OFF VALVE.
CHECK VALVE.
BALANCING VALVE.
UNION.
FLOOR DRAIN.
FLOOR SINK.
TRENCH DRAIN.
FLUSH FLOOR AND GRADE CLEANOUTS.
2 PSI MEDIUM PRESSURE NATURAL GAS PIPING.
DRAIN PIPING.
ROOF DRAIN.
OVERFLOW DRAIN.
OVERFLOW DRAIN NOZZLE.
ROOF DRAIN PIPING.
OVERFLOW DRAIN PIPING.
PLUMBING STACK
ACCESS PANEL
MG
K
HW
V
P
AP
D
CW
FW
(E)XX
FCO
RD
OD
HWR
FD1
FS1
TDPIPE MATERIAL SCHEDULE
SERVICE LOCATION REMARKS
CO
PPER
TYPE
"M"
P.V.
C.
CO
PPER
TYPE
"L"
CO
PPER
TYP
E "K
"
ASB
EST.
CEM
ENT
BLA
CK
STEE
LG
ALVA
NIZ
EDST
EEL
VITR
IFIE
DC
LAY
CAS
T IR
ON
A.B.
S.
WATER
SANITARYDRAINAGE
GAS
SANITARYDRAINAGE
STORMDRAIN
INDIRECTDRAINAGE
INSIDE
ABOVE GRADE
BELOW GRADE
OUTSIDE
INSIDE
OUTSIDE
INSIDE
OUTSIDE
INSIDE
OUTSIDE
INSIDE
OUTSIDE
*
*
*
*
*
*
*
*
*
*
* : ALL METAL PIPES UNDERGROUND SHALL BE PROTECTED BY CORROSION RESISTANCE TAPES.
PEX
1500 GALLONGREASE INTERCEPTOR
MODEL JP1500G
TRAFFIC RATES 24" CAST IRON FRAME & COVER WITH CASKET (TWO STANDARD)
24".
5' - 0" 4' - 9"
6' - 0"
2432 RISER-3",6" OR 12"
AS REQUIRED
4"PVC INLET & OUTLET PIPE AND FITTINGS STANDARD
SIDE VIEW(CUTAWAY)
INLETINVERT
OUTLETINVERT
10' - 8"
5' - 7"
TOP VIEW(COVERS & RISERS REMOVED)
• LIQUID CAPACITY: 1,500 GALLONS
• TANK DESIGNED FOR H-20 TRAFFIC WHEEL LOAD WITH DRY SOIL CONDITIONS (WATER TABLE BELOW TANK) EARTH COVER OVER TANK NOT TO EXCEED 6 FT.
• SUITABLE NATIVE OR SUB-BASE SHALL BE PREPARED TO HANDLE ANTICIPATED LOADS. THE EXCAVATION SHALL BE BEDDED WITH SUITABLE GRANULAR MATERIAL AND SHALL BE COMPACTED TO 90% MAXIMUM DRY DENSITY, OR TO REQUIREMENTS OF THE PROJECT GEOTECHNICAL ENGINEER.
• FOR COMPLETE DESIGN AND PRODUCT INFORMATION CONTACT JENSEN PRECAST.
THE DESIGN AND DETAIL OF THIS DRAWING ARE THE PROPERTY OF JENSEN PRECAST AND NOT TO BE USED EXCEPT IN CONNECTION WITH ITS OWN WORK. DESIGN AND INVENTION RIGHTS ARE RESERVED.
SAMPLE BOXWITH PIPE CONNECTORS
MODEL 2432-Z
MINIMUM EXCAVATION SIZE: 6'-7" X 11'-8" X DEPTH REQ'D.
BOX WEIGHT: 1250 LBS. BOX DESIGN LOAD: H-20 TRAFFIC
SAMPLE BOX MUST BE PLACED ON SUITABLE BASE OF COMPACTED SOIL OR UNDISTURBED EARTH IN TRAFFIC CONDITION. FOR COMPLETE DESIGN AND PRODUCT INFORMATION, CONTACT JENSEN PRECAST.
DETAILPIPE CONNECTOR
(Z-LOK)
PIPE CONNECTOR CAST INTEGRALLY IN WALL. WILL ACCEPT PIPE O.D. (INCHES)
MAX. MIN. 6.25 4.25
SEE Z-LOK PIPE CONNECTOR PAGE FOR ADDITIONAL
INFORMATION
VARIABLE
TOP VIEW(COVERS &
RISERS REMOVED)
OUTSIDE INSIDE
SHOWN WITH PIPE (AFTER INSTALLATION)
SIDE VIEW(CUTAWAY)
COMPACTED FILL OR UNDISTURBED EARTH
PIPE CONNECTOR SEE DETAIL BELOW
24" CAST TRION FRAME & COVER WITH CASKET (GASTIGHT)
2432-12 RISER-12"
2432-06 RISER-6"2432-03 RISER-3"
AS REQUIRED(AT EXTRA COST)VARIABLE
.
VARIABLE36 1/2"
MINIMUM DIA.
24".
32".
17".
DIA.
32".
12".
12" MIN. WHEN SUBJECT TO
TRAFFIC.
STRAP-ON AQUASTAT SET 5° LOWER THAN HEATER
PROVIDE A 210° F ASME APPROVED TEMPERATURE AND 150 PSI PRESSURE RELIEF VALVE WITH TEST LEVER SIZED WITH AGA/CGA TEMPERATURE STEAM RATING 10% OVER HEATER INPUT. PROVIDE A HARD COPPER RELIEF LINE FULL SIZE OF VALVE DISCHARGE OUTSIDE OF BUILDING VALVE OUTLET TO TERMINATE WITHIN 18" OF GRADE.
CW CUT-OFF VALVE
HWR CUT-OFF VALVE
CW CHECK VALVE
HWR CHECK VALVE
HWR CUT-OFF VALVE
HW CUT-OFF VALVE
GAS COCK
DIRT LEG
UNION PROVIDE CONDENSATE DRAIN PIPING TO TERMINATE 6" ABOVE GRADE ON EXTERIOR OF BUILDING.
LOW PROFILE SIDE WALL VENT TERMINAL
PVC EXHAUST FLUE
PRV
WH
(199MBH)
PVC INTAKE
CP
ET
(ST-12)
3/4"HWR
1 1/4"CW
3/4"HWR
1 1/4"CW
1 1/4"CW
3/4"HWR
1 1/4"CW3/4"HWR
1"HW3/4"MG (199MBH)
1"HW
UNION
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
P1.00
XXXXX
BID & PERMIT
XX-XX-XX
PLUMBINGSYMBOLS ANDSCHEDULES
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/4" = 1'-0"3
INDIRECT DRAIN DETAIL
WATER HEATER SIZING CALCULATION
FIXTURE QTY. @GPHEA. = TOTAL GPH HOT WATER STORAGE DEMAND .
LAVATORY 3 @ 5 GPH = 10 GPH GPH MAX. POSSIBLE DEMAND 175
MOP SINK 1 @ 15 GPH = 15 GPH MINUS GPH DISHWASHER 0
HAND SINK 3 @ 5 GPH = 15 GPH EQUALS GPH REMAINING 175
SINK 0 @ 5 GPH = 0 GPH DEMAND FACTOR 0.9
3-COMP SINK 1 @ 90 GPH = 90 GPH EQUALS GPH 158
PREP SINK 1 @ 45 GPH = 45 GPH PLUS GPH DISHWASHER 0
PRE-RINSE 0 @ 45 GPH = 0 GPH GPH MAX. PROBABLE DEMAND 0
DISHWASHER 0 @ 0 GPH = 0 GPH STORAGE FACTOR 0.4
TOTAL = 175 GPH TOTAL GALLONS STORAGE REQUIRED 63
(175 GPH X 80°F X 8.33 LBS PER GAL)96% EFF.
= 122 MBH
2 PSI GAS LOAD CALCULATION
EQUIPMENTGAS LOAD
MBHTDL FOR
BRANCH ONLYBRANCHPIPE SIZE
4-BURNER RANGE 128 100' 3/4"
BROILER 48" 250 100' 3/4"
BROILER 48" W/LIDKIT
250 100' 3/4"
BROILER 60" 300 100' 3/4"
BROILER 60" 300 100' 3/4"
FRYER ASSEMBLY 160 100' 3/4"
GAS RICE COOKER 35 100' 3/4"
ROOFTOP UNIT 150 100' 3/4"
ROOFTOP UNIT 150 100' 3/4"
WATER HEATER 199 100' 3/4"
TOTAL 1922
2 PSI GAS PIPES SIZED BASED FOR TDL=100 FT.MAXIMUM MAIN PIPE SIZE SHALL BE:
PIPE SIZE MAX MBH
1/2" 320
3/4" 669
1" 1,261
1 1/4" 2,588
1 1/2" 3,878
2" 7,469
2 1/2" 11,904
3" 21,044
ITEMS LISTED TO BE PROVIDED BY GC
PLUMBING FIXTURE SCHEDULE
ITEM FIXTURE
CONNECTION SIZES
DESCRIPTIONW V CW HW FW GAS
W1 ADA WATER CLOSET 4" 2" 1" "KOHLER" K-4405 HIGHLINE ELONGATED TOILET BOWL ADA W/ SLOAN VALVE MANUALLY OPERATED. W/ OPEN FRONT SEATS.
W2 WATER CLOSET 4" 2" 1" "KOHLER" K-4405 HIGHLINE ELONGATED TOILET BOWL ADA W/ SLOAN VALVE MANUALLY OPERATED. W/ OPEN FRONT SEATS.
U URINAL 2" 1 1/2" WATERLESS URINAL MODEL SLOAN WES 4000 W/ WES 150 CARTRIDGE KIT.
L ADA LAVATORY 2" 1 1/2" 1/2" 1/2" "KOHLER" PINOIR K-2035 ADA WALL-MOUNT BATHROOM SINK W/ KOHLER 15199 FAUCET, CONTROLS SHALL BE SELF-CLOSING AND LIMITTHE FLOW RATE TO 0.4GPM AND 110°F.
MS MOP SINK W/ STRAINER 3" 2" "FIAT" TSB700 TERRAZZO 12" MOP BASIN WITH STAINLESS STEEL CAPS ON ALL SIDES AND TILE FLANGES ON THREE SIDES.
FD1 EMERGENCY FLOOR DRAIN 2" 1 1/2" ADJUSTABLE COLLAR "ZURN"415 OR "SMITH"2005-Y POLISHED BRONZED W/ STRAINER.
FD2 EMERGENCY FLOOR DRAIN 2" 2" ADJUSTABLE COLLAR "ZURN"415 OR "SMITH"2005-Y POLISHED BRONZED W/ STRAINER.
FD3 FLOOR DRAIN 3" 2" ADJUSTABLE COLLAR "ZURN"415 OR "SMITH"2005-Y POLISHED BRONZED W/ 3" OUTLET.
TD TRENCH DRAIN 2" 1 1/2" JOSAM SERIES 46300 FABRICATED STAINLESS STEEL TRENCH DRAIN WITH 48" LENGTH, 2" OUTLET AND PERFORATED SHEET GRATE.
FS1 FLOOR SINK 2" 1 1/2" COMMERCIAL ENAMELING No. 906-2-C-G 12" x 12" x 6" W/ DOME STRAINER & HALF GRATE.
FS2 FLOOR SINK 3" 2" COMMERCIAL ENAMELING No. 910-3-C-G 12" x 12" x 10" W/ DOME STRAINER & HALF GRATE.
RD ROOF DRAIN J.R. SMITH #1310 W/ SUMP RECEIVER & 5" SHAPED UNDERDECK CLAMP
DSN DOWNSPOUT NOZZLE WADE SERIES 3940 CAST BRONZE DOWNSPOUT NOZZLE WITH THREADED OUTLET. PROVIDE WITH FLANGE TO SECURE TO WALL WITHTAMPERPROOF SCREWS.
GI GREASE INTERCEPTOR 4" 3" JENSEN No. JP1500G 1500 GALLON SHALL BE APPROVED FOR TRAFFIC UP TO 6 FT. COVER L = 10'-8", W = 5'-7", D = 6' MINIMUM. (SEECIVIL DRAWINGS FOR MORE INFORMATION)
MXV MIXING VALVE 1/2" 1/2" BRADLEY "NAVIGATOR" MODEL S59-4016, SIZE 1/2" LOCATED UNDER SINK.
PRV PRESSURE REGULATING VALVE 3/4" MAXITROL MODEL 325 SERIES GAS PRESSURE REGULATING VALVE FOR 2 PSI INLET PRESSURE. PROVIDE WITH MAXITROL "LIMITER"VENT LIMITING DEVICE FOR INDOOR INSTALLATIONS.
BFP1 BACKFLOW PREVENTER 3/4" STAINLESS STEEL BACK FLOW PREVENTER "WATTS" MODEL SS-009 MOUNTED ON WALL. BELOW WATER FILTER. IAPMO FILE NO.1563
HB HOSE BIBB 3/4" J.R.SMITH MODEL 5609QT NON-FREEZE HOSE BIBB WITH INTEGRAL VACUUM BREAKER
WH GAS WATER HEATER 1 1/4" 1" 1" A.O.SMITH BTH 199, 100 GAL., 199,000 BTUH INPUT, 96% EFF. 120V., 60 HZ., POWER
ET EXPANSION TANK AMTROL THERM-X-TROL NO. ST-12
CP CIRCULATING PUMP DOMESTIC HOT WATER CIRCULATING PUMP " GRUNDFOS " MODEL UP 15-18 1/25 HP,120 V. SINGLE PHASE WITH PROGRAMABLE TIMERAND SENSORS.
THE MINIMUM SLOPE FOR DRAINAGE SYSTEM IS 2% UNLESS APPROVED BY THE CITY BUILDING OFFICIAL.
2012 INTERNATIONAL PLUMBING CODE USED FOR DESIGN.
NOT TO SCALE2
PRECAST CONCRETE GREASE INTERCEPTOR DETAIL
NOT TO SCALE1
WATER HEATER DETAIL
REVISIONS
NO. DATE DESCRIPTION
2424
2436
W/H
S2442
F
S2424
S2424
JW
TEA
2424
2424
S1424
S2448
S2448
S2448
2436
G
1. ALL VENT TERMINATIONS ON ROOF SHALL BE MINIMUM OF 10 FT. AWAY FROM A/C UNITS AND MAKE-UP AIR FRESH AIR INTAKE OR ANY OPENING TO THE BUILDING.
2. WALK-IN COOLER BOX CONDENSATE DRAIN SHALL BE 1" COPPER AND TERMINATE OVER FLOOR SINK WITH A P-TRAP AND 1" AIR GAP.
3. EACH VENT SHALL RISE VERTICALLY TO A POINT NOT LESS THAN SIX (6) INCHES IN HEGHT ABOVE THE FLOOD LEVEL RIM OF THE FIXTURE BEFORE BEING CONNECTED TO ANY.
4. ALL WASTE & VENT PIPING IS TO BE CAST IRON. NON-METALLIC PIPE ONLY AS PERMITTED BY LOCAL AUTHORITIES (OR SOILS ENGINEERS FOR BELOW BROUND PIPING). ALL PIPING IN METAL STUD COOK LINE WALLS SHALL BE METALLIC PIPING. NO EXCEPTION.
5. WASTE PIPE DESIGN BASED ON 2% SLOPE.
NOTES:
1 2 3 4 5
D.1
D
C
B
A
CW V
V
GCO GCO
GCO
GCO
2"
1
GI
SAMPLE BOX
(1,500 GAL)
3"
3"
B.2
2
DSN
K
KK
K
K
K
K
K
K
KFCO P100
P137
P115-1
P097
FCO
P016
WH
P016
S020
MS
P016TD
P135B
P135
W1LW1
W2
L
U
FCO
FD1
FD1
P033A
P033
S045
FCO
S015
S015
P125
P123
S047B
FD3
FS2
FS2
FD1
FS1
FS2FD2
FCO
FS1
FCO
FD3
FD3
FD3
FS1
FD2
FS1FS1
4" 4"2"
2"
4"
4" 4" 4"4"
4"4"
4"
3"
4"
4"
4" 4"
4"
4"
2"
4"
4"
4"2"
4"
4"
4"
3"3" 3"3"
3" KK
2"4"4"
2"
2"
3"3"
4" 4" 4" 4" 4"4"
4"
2"
3"
4"
4"
3"
3"
4"
4"
4"
2"
4"
2"
3"
4"
4"
4"
3"3"3"
3
3
3
4"
4"
3
3
45
6
3
3
6
6
66
2
DSN
3
66
S011A
S011B
7
8
9
10
1 1
11
11
11
1111
11
11
11
11
3
FS1 2"
4"
4"
P018
P018-1
113 6
3"
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
P1.10
XXXXX
BID & PERMIT
XX-XX-XX
FLOOR PLAN -LOWER
PLUMBING
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
ALL ITEMS LISTED TO BE PROVIDED BY OWNER
PLUMBING SCHEDULE
EQUIPNO.
QTYREQD. DESCRIPTION
WATER WASTE GAS
PRI_HT REMARKSCW HW FW IW DW SIZE MBH
P015 1 CARBONATORS 1/2" 60" AFF PROVIDE COLD WATER FOR R.P. DEVICE, COKE TO CONNECT FROM R.P. TO CARBONATORS.
P015-1 1 BOOSTER PUMP 3/4" 6" BELOW CLG. PROVIDE 1/2" FEMALE THREADED FITTING FOR COKE TO CONNECT BOOSTER PUMP.
P016 3 HAND SINK, PEDESTAL 1/2" 1/2" 2" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P018 1 ICE MACHINE 1/2" 3/4" 96" AFF FROM FILTER BANK PIPE TO ICE MACHINE. TWO DRAIN CONNECTIONS.
P018-1 1 ICE BIN 3/4" PROVIDE INDIRECT DRAIN TO FLOOR SINK.
P018-5 1 WATER FILTER 3/4" 3/4" 6" BELOW CLG TO FEED (1) 1/2" ICE MACH, (2) 1/2" SODA CARBS (CONN. SODA THRU BFP PRIOR TO CARBONATOR) & ALL BEV MACHINES.
P023 3 FAUCET, POT & PREP SINKS 1/2" 1/2" 14" AFF PROVIDE ALL MATERIALS FOR CONNECTION. USE S/S FLEX LINES & BALL VALVES.
P032 1 4-BURNER RANGE 3/4" 128 30" AFF CONNECT WITH FLEX HOSE.
P033 1 WALK-IN COOLER
P033A 2 WALK-IN COOLER REFRIGERATION 3/4" PROVIDE INSULATED INDIRECT DRAIN PIPING TO FLOOR SINK. PROVIDE APPROVED ROOF PENETRATIONS AS REQUIREDFOR REFRIGERATION PIPING SET INSTALLATION. COORDINATE LOCATION WITH REFRIGERATION PIPING SET INSTALLER.
P034 1 FILLER FAUCET 1/2" 58" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P048 1 FRYER ASSEMBLY 1" 160 12" AFF CONNECT WITH FLEX HOSE.
P054 1 GAS RICE COOKER 1/2" 35 44" AFF CONNECT WITH FLEX HOSE.
P065D 1 BROILER 48" 3/4" 250 18" AFF SEE DETAIL "2" ON SHEET K3
P065E 2 BROILER 60" 3/4" 300 18" AFF SEE DETAIL "2" ON SHEET K3
P066D 1 BROILER 48" W/LID KIT 3/4" 250 18" AFF SEE DETAIL "2" ON SHEET K3
P071 1 FAUCET, MOP SINK 1/2" 1/2" 44" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P076 1 HOT WATER DISPENSER 1/2" 84" AFF PROVIDE ALL MATERIALS FOR CONNECTION, 1/4" O.D. TUBE, 45 DEGREES FLARE. CONN THRU FILTER.
P076-3 1 WATER FILTER 1/2" 1/2" 84" AFF TO HOT WATER DISPENSER.
P095 2 EXHAUST HOOD 1 1/2" PROVIDE DRAIN FROM BLOWERS TO FLOOR SINK SEE DETAIL "1" ON SHEET K3
P097 1 BEVERAGE DISPENSER, SURE FILL 1/2" 3/4" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P097A 1 JUICY WHIP DISP, CUSTOMER 1/2" 1/2" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P097B 1 JUICY WHIP DISPENSER, D.T. 1/2" 1/2" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P098B 1 DUAL BREWER, ICED TEA 1/2" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P100 1 BEVERAGE DISPENSER, PUSH BUTTON 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P115-1 1 REFRIGERATED COLD PAN 3/4" PROVIDE INDIRECT DRAINS FROM SALSA PAN AND BEER DISPLAY TO FLOOR SINK.
P123 8 BUILT-IN FOOD WARMER 1/2" PROVIDE INDIRECT DRAIN TO FLOOR SINK.
P125 1 BUILT-IN SOUP WELLS 1/2" PROVIDE INDIRECT DRAIN TO FLOOR SINK.
P135 1 MARINATING TUMBLER 3/4" PROVIDE INDIRECT DRAIN TO S/S FLOOR SINK.
P135B 1 S/S FLOOR SINK 3" SEE DETAIL ON SHEET P-1 FOR APPROVED FLOOR SINK.
P137 1 SODA DISPENSER MOUNTED ICE MACHINE 1/2" 3/4" 90" AFF FROM FILTER BANK PIPE TO ICE MACHINE.
S011A 1 CHICKEN TROUGH 2" DRAIN THRU COOLER WALL TO FLOOR SINK MIN. 6" AFF.
S015 2 BROILER PAN, WATER BATH 1/2" 2" 48" AFF PROVIDE ALL MATERIALS FOR CONNECTION. OUTSET SPOUT @ +18". BALL VALVE IN S/S. ACCESS COVER @ 48"
S020 1 3-COMP SINK 3" PROVIDE ALL MATERIAL FOR CONNECTION. VER WASTE W/ P SHTS.
S026A 1 BURRITO & SIDES ASSEMBLY 3/4" PROVIDE INDIRECT DRAINS TO FLR SINK FOR REFRIGERATED BASE.
S047B 1 PAN CHILLERS 1/2" PROVIDE INSULATED INDIRECT DRAIN TO FLOOR SINK
PLAN NOTES
1 SEE SITE PLAN FOR CONTINUATION.
2 4"RD DOWN FROM ABOVE.
3 1 1/2"V UP
4 2"CW UP
5 3"V UP
6 2"V UP
7 RUN ALL INDIRECT DRAIN PIPING IN COOLER TIGHT TO WALL.
8 G.C. TO PROVIDE ACCESS THRU WALL FOR DRAIN LINE.
9 PROVIDE INSULATED CONDENSATE DRAIN PIPING TIGHT TO WALL TO CLOSEST FLOOR SINK TO TERMINATE WITH APPROVED AIR GAP. INSTALL OWNER PROVIDED REFRIGERANT LINE SET TO REMOTE CONDSER.
10 PROVIDE ALL INDIRECT DRAIN PIPING AS REQUIRED TO EXTERIOR OF BUILING AND TERMINATE MINIMUM OF 6" ABOVE GRADE.
11 PROVIDE INDIRECT DRAIN PIPING TO CLOSEST FLOOR SINK TO TERMINATE WITH APPROVED AIR GAP.
1/4" = 1'-0"1
FIRST FLOOR PLAN - LOWER PLUMBING
REVISIONS
NO. DATE DESCRIPTION
2424
2436
W/H
S2442
F
S2424
S2424
JW
TEA
2424
2424
S1424
S2448
S2448
S2448
2436
G
USE PEX TUBING OR EQUIVALENT DOWN STREAM OF BACK FLOW PREVENTER.
STAINLESS STEEL BACK FLOW PREVENTER ON WALL. BELOW WATER FILTER (COKE TO MAKE CONNECTION FROM THIS POINT TO CARBONATORS.) PROVIDE INDIRECT DRAIN PIPING TO CLOSEST FLOOR SINK TO TERMINATE WITH APPROVED AIR GAP.
FW CUT-OFF VALVE
FW CUT-OFF VALVE
CW CUT-OFF VALVE
CW CUT-OFF VALVE3/4"FW TO EQUIPMENT
3/4"FW
3/4"FW
3/4"FW
3/4"FW
3/4"FW
3/4"FW
3/4"FW
3/4"CW
3/4"CW
3/4"CW
P018-5
P015-1
1
2 3 4 5
D.1
D
C
B
A
HB
CW
CW
1
3/4"
3/4"
3/4"
2
2
3
3 4
4
44
P097B
P097
P016
P100
P137
P098B
P097A
P018
WH
ETCP
P016
P023
P023
P071
P016
MS
P018-5
P015-1
5W1
U
L W1
W2
L
4
6
4
7
7
7
77
S015
S015
P076-3
P076MXV
MXV
MXV
8
MXV
P3
6
P2
P1 P4
CW
CW
CW
HW
CW
CW
FW
V
V
V
VHWHW
HWR
HW
R D
DD
D
D
D
D
CW
HW
CW
HW
HW
R
HWRCW
HW
FW
HW
HW
R
V
V
FW
FW
V
FWHW
HW
9
10
10
11
12
HW
CW
CW
CW
VV
VV
3/4"HW
3/4"CW
2"V
13
HB
3/4"1 1/2"
3/4"
1 1/2"3/4"
1 1/4" 2"
2"1 1/4" 1/2"
1 1/4"
2"
2"
2 1/2"
2"
2"2" 2"
2" 2" 14
1 1/4"
2"
2"
2"
2"
1"1"
2"
1/2"
1/2"
2"
1/2"
1/2" 3/4"
3/4"
3/4"1 1/2"1 1/2"1"
1"
3/4"1/2" 3/4"
1/2"
1 1/2" 1 1/2"3/4"
3/4"1"
1/2"
1/2"
1/2"
1"1"
3/4"
2"3/4"
1 1/2"
1 1/2"
2"
1 1/2"
1 1/2"
2"
2"7
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
2"
4
3/4"
1 1/2"
3/4"
3/4"
3/4"
3/4"
2"
3/4"
2"2 1/2"
V
1 1/2"
3/4"1/2"
3/4"
3/4"
1 1/4"
1"
3/4"
3/4"
3/4"
2"1/2"
3/4"
2" 2"2"
1/2"
2"
2"
2"
1 1/2"
1 1/2"
3/4"
1 1/2"
1 1/2" 1/2"
3/4"
3/4"
LOW PROFILE SIDE WALL VENT TERMINATION.
(100 GAL., 199 MBH)
(ST-12)
S020
3"V
4
P023
P015
P034
4"RD
15
1/2"2"
1 1/2"
16
4"RD
2" 2 1/2"V
7
4
CW
FWFW
3/4"
FWFW1/2"
3/4"
1/2"
7 4
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
P1.20
XXXXX
BID & PERMIT
XX-XX-XX
FLOOR PLAN -UPPER PLUMING
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
PLAN NOTES
1 3"V UP FROM BELOW
2 4"RD DN FROM 4" ROOF DRAIN
3 4"RD DN
4 1 1/2"V UP FROM BELOW
5 3"V UP TO 3"VTR
6 2 1/2"V UP TO 2 1/2"VTR
7 2"V UP FROM BELOW
8 2"V UP TO 2"VTR
9 TERMINATE CONDENSATE DRAIN PIPING INTO MOP SINK WITH APPROVED AIR GAP.
10 1" CONDENSATE DRAIN DN FROM ABOVE.
11 3/4"CW UP TO HOSE BIBB ON ROOF.
12 VERIFY FILTER SCHEMATIC W/ DETAIL 2/P1.20. CONNECT THRU BOOSTER PUMP THEN FILTER.
13 PROVIDE HOT WATER SHUT OFF VALVE IN WALL WITH ACCESS PANEL.
14 2"CW UP FROM BELOW
15 1/2"CW UP TO "MAU-1"
16 1 1/2" CONDENSATE DRAIN DN FROM ABOVE.
ALL ITEMS LISTED TO BE PROVIDED BY OWNER
PLUMBING SCHEDULE
EQUIPNO.
QTYREQD. DESCRIPTION
WATER WASTE GAS
PRI_HT REMARKSCW HW FW IW DW SIZE MBH
P015 1 CARBONATORS 1/2" 60" AFF PROVIDE COLD WATER FOR R.P. DEVICE, COKE TO CONNECT FROM R.P. TO CARBONATORS.
P015-1 1 BOOSTER PUMP 3/4" 6" BELOW CLG. PROVIDE 1/2" FEMALE THREADED FITTING FOR COKE TO CONNECT BOOSTER PUMP.
P016 3 HAND SINK, PEDESTAL 1/2" 1/2" 2" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P018 1 ICE MACHINE 1/2" 3/4" 96" AFF FROM FILTER BANK PIPE TO ICE MACHINE. TWO DRAIN CONNECTIONS.
P018-1 1 ICE BIN 3/4" PROVIDE INDIRECT DRAIN TO FLOOR SINK.
P018-5 1 WATER FILTER 3/4" 3/4" 6" BELOW CLG TO FEED (1) 1/2" ICE MACH, (2) 1/2" SODA CARBS (CONN. SODA THRU BFP PRIOR TO CARBONATOR) & ALL BEV MACHINES.
P023 3 FAUCET, POT & PREP SINKS 1/2" 1/2" 14" AFF PROVIDE ALL MATERIALS FOR CONNECTION. USE S/S FLEX LINES & BALL VALVES.
P032 1 4-BURNER RANGE 3/4" 128 30" AFF CONNECT WITH FLEX HOSE.
P033 1 WALK-IN COOLER
P033A 2 WALK-IN COOLER REFRIGERATION 3/4" PROVIDE INSULATED INDIRECT DRAIN PIPING TO FLOOR SINK. PROVIDE APPROVED ROOF PENETRATIONS AS REQUIREDFOR REFRIGERATION PIPING SET INSTALLATION. COORDINATE LOCATION WITH REFRIGERATION PIPING SET INSTALLER.
P034 1 FILLER FAUCET 1/2" 58" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P048 1 FRYER ASSEMBLY 1" 160 12" AFF CONNECT WITH FLEX HOSE.
P054 1 GAS RICE COOKER 1/2" 35 44" AFF CONNECT WITH FLEX HOSE.
P065D 1 BROILER 48" 3/4" 250 18" AFF SEE DETAIL "2" ON SHEET K3
P065E 2 BROILER 60" 3/4" 300 18" AFF SEE DETAIL "2" ON SHEET K3
P066D 1 BROILER 48" W/LID KIT 3/4" 250 18" AFF SEE DETAIL "2" ON SHEET K3
P071 1 FAUCET, MOP SINK 1/2" 1/2" 44" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P076 1 HOT WATER DISPENSER 1/2" 84" AFF PROVIDE ALL MATERIALS FOR CONNECTION, 1/4" O.D. TUBE, 45 DEGREES FLARE. CONN THRU FILTER.
P076-3 1 WATER FILTER 1/2" 1/2" 84" AFF TO HOT WATER DISPENSER.
P095 2 EXHAUST HOOD 1 1/2" PROVIDE DRAIN FROM BLOWERS TO FLOOR SINK SEE DETAIL "1" ON SHEET K3
P097 1 BEVERAGE DISPENSER, SURE FILL 1/2" 3/4" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P097A 1 JUICY WHIP DISP, CUSTOMER 1/2" 1/2" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P097B 1 JUICY WHIP DISPENSER, D.T. 1/2" 1/2" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P098B 1 DUAL BREWER, ICED TEA 1/2" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P100 1 BEVERAGE DISPENSER, PUSH BUTTON 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P115-1 1 REFRIGERATED COLD PAN 3/4" PROVIDE INDIRECT DRAINS FROM SALSA PAN AND BEER DISPLAY TO FLOOR SINK.
P123 8 BUILT-IN FOOD WARMER 1/2" PROVIDE INDIRECT DRAIN TO FLOOR SINK.
P125 1 BUILT-IN SOUP WELLS 1/2" PROVIDE INDIRECT DRAIN TO FLOOR SINK.
P135 1 MARINATING TUMBLER 3/4" PROVIDE INDIRECT DRAIN TO S/S FLOOR SINK.
P135B 1 S/S FLOOR SINK 3" SEE DETAIL ON SHEET P-1 FOR APPROVED FLOOR SINK.
P137 1 SODA DISPENSER MOUNTED ICE MACHINE 1/2" 3/4" 90" AFF FROM FILTER BANK PIPE TO ICE MACHINE.
S011A 1 CHICKEN TROUGH 2" DRAIN THRU COOLER WALL TO FLOOR SINK MIN. 6" AFF.
S015 2 BROILER PAN, WATER BATH 1/2" 2" 48" AFF PROVIDE ALL MATERIALS FOR CONNECTION. OUTSET SPOUT @ +18". BALL VALVE IN S/S. ACCESS COVER @ 48"
S020 1 3-COMP SINK 3" PROVIDE ALL MATERIAL FOR CONNECTION. VER WASTE W/ P SHTS.
S026A 1 BURRITO & SIDES ASSEMBLY 3/4" PROVIDE INDIRECT DRAINS TO FLR SINK FOR REFRIGERATED BASE.
S047B 1 PAN CHILLERS 1/2" PROVIDE INSULATED INDIRECT DRAIN TO FLOOR SINK
NOT TO SCALE2
WATER FILTER & BACKFLOW DETAIL
1/4" = 1'-0"1
FIRST FLOOR PLAN - UPPER PLUMBING
REVISIONS
NO. DATE DESCRIPTION
2424
2436
W/H
S2442
F
S2424
S2424
JW
TEA
2424
2424
S1424
S2448
S2448
S2448
2436
G
1. GAS PIPING SHALL BE KEPT A MINIMUM OF 6 INCHES ABOVE GRADE OR STRUCTURE.
NOTE:
6".
12".
9".
2' - 0".
4".
1/4"Ø STEEL PIPE (GALVANIZED)
ONE HOLE PIPE STRAP (GALVANIZED)
1/8" TK. COMP. ROOFING
4" X 4" X 12" TREATED TIMBERPIPE SIZE AS SHOWN ON PLANS
GRAVEL
BUIT-UP ROOF OR GROUND
TOP VIEW
END VIEW
1 2 3 4 5
D.1
D
C
B
A
MG
TOTAL DEVELOPED LENGTH 100 FT. TOTAL 1,922MBH, 2 PSI GAS METER & PRESSURE REGULATOR BY GAS COMPANY.
GAS METER
SHUT-OFF VALVE
B.2
MGMG
MG
MG
MG
MG
MG
MG
MG
MG
MG
3/4"MG UP TO 'RT-2'(150MBH)
3/4"MG UP TO 'RT-1'(150MBH)
3/4"(150MBH)
3/4"(150MBH) 3/4"(150MBH)
1 1/4"(1,423MBH)
PROVIDE CEILING ACCESS PANEL WITH LABEL IDENTIFYING THE LOCATION OF THE AUTOMATIC GAS SHUT-OFF VALVE
AUTOMATIC GAS S.O.V. TO BE INTERLOCKED WITH FIRE SUPPRESSION SYSTEM PROVIDED BY G.C. INSTALLED BY P.C.
1 1/4"(1,423MBH)
1 1/4"(1,263MBH)
3/4"(160MBH)
3/4"(160MBH)
3/4"(160MBH)
3/4"(160MBH)
P048
P065E P066D
P065E
3/4"(199MBH)
3/4"(349MBH)
1 1/4"(1,573MBH)
1 1/4"(1,922MBH)
P065D P032
P054
3/4"(128MBH)
1 1/4"(1,100MBH)1"(850MBH)
1"(600MBH)3/4"(300MBH)
3/4"(0MBH)
WH
(300MBH) (250MBH)
(300MBH) (250MBH)
(128MBH)
(35MBH)
(160MBH)
(199MBH)
MG
3/4"(150MBH)
3/4"(349MBH)
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
P1.30
XXXXX
BID & PERMIT
XX-XX-XX
FLOOR PLAN -GAS PLUMBING
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
MAXIMUM DELIVERY CAPACITY OF ONETHOUSAND BTUS OF GAS PER HOUR OF IPSPIPE CARRYING NATURAL GAS OF 0.60SPECIFIC GRAVITY BASED ON PRESSUREDROP OF 1.5 PSI
TDL = 100 FT.
2 PSI NATURAL GAS SIZING GAS PIPINGSYSTEM
PIPE SIZE MBH
1/2" 320
3/4" 669
1" 1,261
1 1/4" 2,588
1 1/2" 3,878
2" 7,469
2 1/2" 11,904
3" 21,044
NOT TO SCALE2
GAS PIPE SUPPORT DETAIL
1/4" = 1'-0"1
FIRST FLOOR PLAN - GAS PLUMBING
ALL ITEMS LISTED TO BE PROVIDED BY OWNER
PLUMBING SCHEDULE
EQUIPNO.
QTYREQD. DESCRIPTION
WATER WASTE GAS
PRI_HT REMARKSCW HW FW IW DW SIZE MBH
P015 1 CARBONATORS 1/2" 60" AFF PROVIDE COLD WATER FOR R.P. DEVICE, COKE TO CONNECT FROM R.P. TO CARBONATORS.
P015-1 1 BOOSTER PUMP 3/4" 6" BELOW CLG. PROVIDE 1/2" FEMALE THREADED FITTING FOR COKE TO CONNECT BOOSTER PUMP.
P016 3 HAND SINK, PEDESTAL 1/2" 1/2" 2" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P018 1 ICE MACHINE 1/2" 3/4" 96" AFF FROM FILTER BANK PIPE TO ICE MACHINE. TWO DRAIN CONNECTIONS.
P018-1 1 ICE BIN 3/4" PROVIDE INDIRECT DRAIN TO FLOOR SINK.
P018-5 1 WATER FILTER 3/4" 3/4" 6" BELOW CLG TO FEED (1) 1/2" ICE MACH, (2) 1/2" SODA CARBS (CONN. SODA THRU BFP PRIOR TO CARBONATOR) & ALL BEV MACHINES.
P023 3 FAUCET, POT & PREP SINKS 1/2" 1/2" 14" AFF PROVIDE ALL MATERIALS FOR CONNECTION. USE S/S FLEX LINES & BALL VALVES.
P032 1 4-BURNER RANGE 3/4" 128 30" AFF CONNECT WITH FLEX HOSE.
P033 1 WALK-IN COOLER
P033A 2 WALK-IN COOLER REFRIGERATION 3/4" PROVIDE INSULATED INDIRECT DRAIN PIPING TO FLOOR SINK. PROVIDE APPROVED ROOF PENETRATIONS AS REQUIREDFOR REFRIGERATION PIPING SET INSTALLATION. COORDINATE LOCATION WITH REFRIGERATION PIPING SET INSTALLER.
P034 1 FILLER FAUCET 1/2" 58" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P048 1 FRYER ASSEMBLY 1" 160 12" AFF CONNECT WITH FLEX HOSE.
P054 1 GAS RICE COOKER 1/2" 35 44" AFF CONNECT WITH FLEX HOSE.
P065D 1 BROILER 48" 3/4" 250 18" AFF SEE DETAIL "2" ON SHEET K3
P065E 2 BROILER 60" 3/4" 300 18" AFF SEE DETAIL "2" ON SHEET K3
P066D 1 BROILER 48" W/LID KIT 3/4" 250 18" AFF SEE DETAIL "2" ON SHEET K3
P071 1 FAUCET, MOP SINK 1/2" 1/2" 44" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P076 1 HOT WATER DISPENSER 1/2" 84" AFF PROVIDE ALL MATERIALS FOR CONNECTION, 1/4" O.D. TUBE, 45 DEGREES FLARE. CONN THRU FILTER.
P076-3 1 WATER FILTER 1/2" 1/2" 84" AFF TO HOT WATER DISPENSER.
P095 2 EXHAUST HOOD 1 1/2" PROVIDE DRAIN FROM BLOWERS TO FLOOR SINK SEE DETAIL "1" ON SHEET K3
P097 1 BEVERAGE DISPENSER, SURE FILL 1/2" 3/4" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P097A 1 JUICY WHIP DISP, CUSTOMER 1/2" 1/2" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P097B 1 JUICY WHIP DISPENSER, D.T. 1/2" 1/2" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P098B 1 DUAL BREWER, ICED TEA 1/2" 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P100 1 BEVERAGE DISPENSER, PUSH BUTTON 18" AFF PROVIDE ALL MATERIALS FOR CONNECTION.
P115-1 1 REFRIGERATED COLD PAN 3/4" PROVIDE INDIRECT DRAINS FROM SALSA PAN AND BEER DISPLAY TO FLOOR SINK.
P123 8 BUILT-IN FOOD WARMER 1/2" PROVIDE INDIRECT DRAIN TO FLOOR SINK.
P125 1 BUILT-IN SOUP WELLS 1/2" PROVIDE INDIRECT DRAIN TO FLOOR SINK.
P135 1 MARINATING TUMBLER 3/4" PROVIDE INDIRECT DRAIN TO S/S FLOOR SINK.
P135B 1 S/S FLOOR SINK 3" SEE DETAIL ON SHEET P-1 FOR APPROVED FLOOR SINK.
P137 1 SODA DISPENSER MOUNTED ICE MACHINE 1/2" 3/4" 90" AFF FROM FILTER BANK PIPE TO ICE MACHINE.
S011A 1 CHICKEN TROUGH 2" DRAIN THRU COOLER WALL TO FLOOR SINK MIN. 6" AFF.
S015 2 BROILER PAN, WATER BATH 1/2" 2" 48" AFF PROVIDE ALL MATERIALS FOR CONNECTION. OUTSET SPOUT @ +18". BALL VALVE IN S/S. ACCESS COVER @ 48"
S020 1 3-COMP SINK 3" PROVIDE ALL MATERIAL FOR CONNECTION. VER WASTE W/ P SHTS.
S026A 1 BURRITO & SIDES ASSEMBLY 3/4" PROVIDE INDIRECT DRAINS TO FLR SINK FOR REFRIGERATED BASE.
S047B 1 PAN CHILLERS 1/2" PROVIDE INSULATED INDIRECT DRAIN TO FLOOR SINK
REVISIONS
NO. DATE DESCRIPTION
ROOF SURFACE
AC UNIT
1" TEE/LOOSE CAP. FOR CLEANOUT
1" OPEN TEE VENT
1" COND. DRAIN TO MS1
1. ALL THE VENTS SHOULD BE 10 FEET AWAY FROM AIR INTAKE OF AC UNITS & MUA UNIT.
2. CONDENSATE AND GAS PIPING FOR ROOF TOP EQUIPMENT SHALL INSTALL BELOW THE ROOF.
3. STORM DRAIN PIPE SIZES BASED ON 2% SLOPE & 5" RAIN FALL PER HOUR
NOTES:
PROVIDE DIRT LEG, PRESSURE REGLUATING VALVE & SHUT-OFF VALVE AT EACH UNIT. MAKE FINAL CONNECTION W/ APPROVED FLEXIBLE CONNECTOR.
12 3 4 5
D.1
D
C
B
A
RT
1
RT
2
KF
2
KF
1
EF
1
KF
3
1
1
HB
3/4"CW UP FROM BELOW
4" ROOF DRAIN W/ 8"X6" OVERFLOW SCUPPER FOR 1,725 SF
2
2
RD
RD
4" ROOF DRAIN W/ 8"X6" OVERFLOW SCUPPER FOR 1,132 SF
P4
P1
P2
P3
(150MBH)
(150MBH)
3/4"MG UP FROMBELOW (150MBH)
3/4"MG UP FROMBELOW (150MBH)
MAU
1
P033A
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
P1.40
XXXXX
BID & PERMIT
XX-XX-XX
ROOF PLAN -PLUMBING
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
NOT TO SCALE2
CONDENSATE DRAIN DETAIL
1/4" = 1'-0"1
ROOF PLAN - PLUMBING
PLAN NOTES
1 1" CONDENSATE DRAIN DOWN
2 3" BELL W/ 1 1/2" DRAIN TO FLOOR SINK FOR GREASE DRAIN VERIFY LOCATION.
REVISIONS
NO. DATE DESCRIPTION
3/4" (1.0)
3/4" (1.0)
3/4" (1.0)
3/4" (1.0)
3/4" (1.0)
3/4" (2.0)
3/4" (2.0)
3/4" (3.0)
1 1/4" (7.5)
1 1/4" (7.5)
1 1/4" (7.5)
1" (6.0)
1" (6.0)
1/2" (1.5)
1/2" (0.5)
1/2" (1.0)
1/2" (1.0)1/2" (0.5)
1/2" (0.5)
1/2" (0.5)
W1
U
L
MXV
W1
W2
L
P016
P018-5
P015-1
P023
P023P016
S015
S015
P016
P097
P097BP100
P098B
P097A
P137
P076-3
P0763/4" (2.0)
1 1/4" (10.5)
2" (56.5)
1 1/4" (7.5)2" (64.0)
2" (64.0)
1 1/4" (7.5)
1" (6.0)
1/2" (1.5)
1" (6.0)
1" (6.0)
1" (6.0)
1" (6.0)
1/2" (1.0)1/2" (0.5)
1/2" (0.5)
1/2" (0.5)1/2" (0.5)
1/2" (0.5)
1/2" (0.5)
2" (46.0)
2" (39.0)
2" (39.0)
3/4" (13.0)
3/4" (13.0)
1 1/2" (26.0)
1 1/2" CW (26.0)
3/4" (13.0)
3/4" (3.5) 3/4" (3.5)
3/4" (8.0)
3/4" (10.0)
3/4" (10.0)
3/4" (3.0)3/4" (3.0)
3/4" (10.0)
3/4" (13.0)
ET
CP
1/2" (1.0)1/2" (1.0)
1/2" (1.0)
3/4" (2.0)
1/2" (1.0)3/4" (1.0)
1/2" (0.5)
3/4" (5.5)
1 1/2" (20.5)
3/4" (7.0)
3/4" (7.0)
HB
HB+18"
+18"
3/4" (2.5)
3/4" (2.5)
3/4" CW (1.5)
3/4" (4.0)
3/4" (2.5)
3/4" CW (1.5)3/4" HW (1.5) 3/4" (1.5)3/4" HW (1.5) 3/4" (1.5)
3/4" (1.5)3/4" (1.5)
3/4" (3.0)
1/2" CW (1.5)
1/2" (1.5)
1/2" CW (1.0)
1/2" (1.0)
1/2" (0.5)
1/2" CW (0.5)
MXV
1/2" HW (0.5)
1/2" (0.5)
1/2" HW (0.5)
3/4" (2.0)
3/4" (3.5)
1 1/2" (13.5)
1 1/4" (9.5)
1 1/4" (9.5)1 1/4" (9.5)
3/4" (0.0)3/4" (0.0)
3/4" (0.0)
WH(100 GAL., 199MBH)
3/4"
3/4"
1" (9.5)
1" (9.5)
3/4" (9.0)
1/2" (0.5)
1/2" (0.5)
MXV
3/4" (4.0)
HB 3/4" (2.5)
3/4" (2.5)
3/4" (2.5)3/4" (2.5)
1/2" (1.5)
1/2" (1.5)
UP TO MAU 1
3/4" (3.5)
3/4" (5.5)
3/4" (2.0)
1/2" (1.0)
1/2" (1.0)
1/2" (1.0)3/4" (1.0)
3/4" (0.5)
1/2" (0.5)
1/2" (0.5)
1/2" (0.5)
1/2" (0.5)
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"HWR
3/4"
3/4"
1/2" (5.0)
1/2" (5.0)1/2" (2.0)1/2" (2.0)
1/2" (3.0)
1/2" (1.0)
1/2" (2.0)
1/2" (2.0)
1/2" (2.0)
1/2" (2.0)
1/2" (1.0)
1/2" (1.0)
1/2" (1.0)
3/4" (7.0)
3/4" (7.0)
1/2" (1.0)
1/2" (1.0)1/2" (1.0)
3/4" (8.0)
HW
CW
HW
HWR
HW
CW
FW
FW
CW
HW
HW
HW
HW
CW
CW
CW
CW
CW
CW
CW
CW
HWHW
FW
CW 2" (64.0)
2" (64.0)
1 1/4" (9.5)
P071
MXV
MXV
(ST-12)
P034
1/2" (1.0)
1/2" (1.0)
1/2"CW UP TO 'MAU-1'
P023
1/2" CW (1.5)
3/4" HW (1.5)
3/4" HW (1.5)3/4" CW (1.5)
1/2" CW (1.0)
CW
1/2" (0.5)
1/2" (1.0)
3/4" (1.5)
3/4" (2.0) 3/4" (1.5)
3/4" (3.0)
3/4" (5.5)
3/4" (2.5)
FW
FW
1/2" (2.0)1/2" (2.0)
1/2" (2.0)
1/2" (2.0)
3/4" FW (3.0)
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
P1.70
XXXXX
BID & PERMIT
XX-XX-XX
DOMESTICWATER RISER
DIAGRAM
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
NOT TO SCALE1
DOMESTIC WATER RISER DIAGRAM
REVISIONS
NO. DATE DESCRIPTION
2" (2.0) 2" (2.0)3" (0.0)
3" (0.0)
FCO
3" (2.0)
2" (2.0)
2" (2.0)
3" (4.0)
3" (6.0)
3" (6.0)
3" (3.0)
4" (10.0)
4" (7.0)
2" (2.0)
2" (2.0)2" (0.0)
2" (0.0)
2" (0.0)
2" (1.0)
2" (1.0)
3" (3.0)
3" (3.0)
4" (1.0)
FS1
FS1
FS1
FD1
FS2
FD3
FD2
FCO
FS1
FCO
FD3
FS2FD3
FS2
FD2
FS1
FCO
FD1
FD1
FCO
GCO
GCO
4" (41.0) 6" (69.0)
4" (28.0)
4" (28.0)
GCO
GCO
FS1
FD3
W1
W2L
W1
L
P135B
P016
P016
S020
MS
P016
WH
P2
P4
P1
P3
3" (3.0)
2" (0.0)
2" (0.0)
4" (10.0)
4" (10.0)
4" (0.0)
4" (11.0)
3" (3.0)
4" (17.0)
3" (6.0)
3" (6.0)
3" (3.0)
3" (3.0)
3" (3.0)
4" K (22.0) 4" (25.0)
3" (3.0)
2" (1.0)
4" (29.0)
4" (31.0)
3" (5.0)
3" (5.0)
3" (0.0)
3" (3.0)
3" (3.0)
2" (0.0)
2" (0.0)
3" (3.0)
4" (0.0)
4" (6.0)
2" (1.0)
2" (1.0)
3" (3.0)
2" (2.0)2" (2.0)
2" (2.0)
4" (38.0)
2" (2.0)
2" (2.0)
2" (2.0)
4" (41.0)
3" (3.0)
4" (41.0)
4" (0.0)
4" (6.0)
4" (6.0)
4" (0.0)
4" (6.0)
2" (2.0)
2" (2.0)
2" (2.0)
4" (8.0)
2" (0.0)
2" (0.0)
2" (1.0)
2" (1.0)
4" (9.0)
4" (6.0)4" (6.0)
4" (15.0)
4" (28.0)
GCO
4" (6.0)
4" (6.0)
2" (0.0)
4" (13.0)
4" (13.0)
4" (7.0)
2" (1.0)
2" (1.0)4" (6.0)
TD
GI(1,500 GALLON)
K
K
K
K
K
K
K
1 1/2" (1.0)
1 1/2" (0.0)
2" (6.0)
1 1/2" (1.0)
1 1/2" (1.0)
2" (7.0)
2" (7.0)
V
1 1/2" (2.0)
2" (9.0)
V
2" (20.0)
2" (7.0)
2 1/2" (27.0)
2 1/2"VTR
2" (7.0)
2" (11.0)
2" (6.0)2" (6.0)
2" (5.0)
3" (0.0)
3" (0.0)
3" (0.0)
3" (0.0)
3" (0.0)3" (0.0)
3" (0.0)
3"VTR
1 1/2" (2.0)
2" (3.0)
2" (3.0)
2" (3.0)
2" (3.0)
2" (5.0)
1 1/2" (2.0)
2" (7.0)
2" (9.0)
2" (16.0)
2 1/2" (26.0) 2 1/2"VTR
2" (10.0)
2" (10.0)
2" (3.0)
2" (3.0)
1 1/2" (1.0)
2" (7.0)
2" (6.0)
1 1/2" (1.0)
3"
2" (5.0)
2" (9.0)
1 1/2" (1.0)
2" (3.0)
2" (3.0)
1 1/2" (1.0)
2" (6.0)
1 1/2" (0.0)
1 1/2" (1.0)
1 1/2" (1.0)
2" (6.0)
2" (5.0)1 1/2" (0.0)
2" (3.0)1 1/2" (2.0)
2" (6.0)
2" (18.0)2" (18.0)
2" (14.0)
2" (14.0)
2" (5.0)
2" (5.0)
2" (3.0)2" (0.0)
2"V (5.0)
2" (9.0)
2" (3.0)
2" (6.0)
2" (3.0)
1 1/2" (1.0)
1 1/2" (2.0)1 1/2" (0.0)
1 1/2" (2.0)
1 1/2" (2.0)
2" (3.0)
2" (3.0)
2" (6.0)
2" (3.0)
1 1/2" (4.0)
1 1/2" (2.0)
1 1/2"
1 1/2" (2.0)
1 1/2"
1 1/2" (2.0)
1 1/2" (2.0)
1 1/2" (2.0)
2 1/2" (26.0)
1 1/2" (2.0)
1 1/2" (1.0)2" (4.0)
1 1/2" (2.0)
1 1/2" (2.0)
2" (7.0)
2" (7.0)
K
K
K
K
K
KK
K
K
V
V
V
V
V
V
V
V V
V
V
V
V
V
V
V
V
V
V
VV
V
V
LOW PROFILE SIDE WALL VENT TERMINATION.
U
2"VTR
1 1/2" (2.0)
1 1/2" (2.0)
4" (41.0)
4" (41.0)
4" (41.0)
SAMPLING PORT
4" (0.0)
4" (1.0)
3" (3.0)
4" (36.0)
4" (28.0)
V
2 1/2" (27.0)
2" (5.0)
V
1 1/2" (2.0)2" (5.0)
4" (19.0)
1 1/2" (2.0)
2" (3.0)2" (0.0)
2" (5.0)
K
2" (2.0)3" (3.0)
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
P1.80
XXXXX
BID & PERMIT
XX-XX-XX
WASTE & VENTRISER DIAGRAM
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
NOT TO SCALE1
WASTE & VENT RISER DIAGRAM
REVISIONS
NO. DATE DESCRIPTION
RT
1
RT
2
AUTOMATIC GAS S.O.V. TO BE INTERLOCKED WITH FIRE SUPPRESSION SYSTEM PROVIDED BY G.C. INSTALLED BY P.C.
TOTAL DEVELOPED LENGTH 100 FT. TOTAL 1,922MBH, 2 PSI GAS METER & PRESSURE REGULATOR BY GAS COMPANY.
GAS METER
SHUT-OFF VALVE
MG
(150MBH)
(150MBH)
MG
MG
MG
MG
MG
MG
MG
MGMG
MG
MG
MG
WH
PRV
PRV
PRV
PRV
PRV
PRV
PRV
PRV
PRV
PRV
P048
P065E
P065E
P065D
P066D
P054
P032
(300MBH)
(300MBH)
(250MBH)
(250MBH)
(35MBH)
(128MBH)
(160MBH)
(199MBH)
3/4"(150MBH)
3/4"(150MBH)
3/4"(150MBH)3/4"(150MBH)
3/4"(150MBH)
3/4"(150MBH)
3/4"(150MBH)
1 1/4"(1,423MBH)
1 1/4"(1,573MBH)
1 1/4"(1,922MBH)
1 1/4"(1,573MBH)
3/4"(349MBH)1 1/4"(1,922MBH)
1 1/4"(1,922MBH)
1 1/4"(1,922MBH)
3/4"(199MBH)
3/4"(199MBH)
3/4"(199MBH)
1 1/4"(1,423MBH)
1 1/4"(1,263MBH)
3/4"(160MBH)
3/4"(160MBH)3/4"(160MBH)
3/4"(160MBH)
3/4"(160MBH)
3/4"(160MBH)
1 1/4"(1,263MBH)
3/4"(163MBH)
3/4"(128MBH)
3/4"(128MBH)
3/4"(35MBH)
3/4"(0MBH)
1 1/4"(1,100MBH)
1"(850MBH)
3/4"(250MBH)
1"(600MBH)
3/4"(250MBH)
3/4"(300MBH)
3/4"(300MBH)3/4"(0MBH)
3/4"(300MBH)
MG
MG
3/4"(150MBH)
3/4"(349MBH)
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
P1.90
XXXXX
BID & PERMIT
XX-XX-XX
GAS RISERDIAGRAM
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
MAXIMUM DELIVERY CAPACITY OF ONETHOUSAND BTUS OF GAS PER HOUR OF IPSPIPE CARRYING NATURAL GAS OF 0.60SPECIFIC GRAVITY BASED ON PRESSUREDROP OF 1.5 PSI
TDL = 100 FT.
2 PSI NATURAL GAS SIZING GAS PIPINGSYSTEM
PIPE SIZE MBH
1/2" 320
3/4" 669
1" 1,261
1 1/4" 2,588
1 1/2" 3,878
2" 7,469
2 1/2" 11,904
3" 21,044
NOT TO SCALE1
GAS RISER DIAGRAM
REVISIONS
NO. DATE DESCRIPTION
2424
2436
W/H
S2442
F
S2424
2424
2424
S2448
S2448
S2448
2436
G
A-0
03
9
7
8 8 8
SCR
EEN
FO
RPA
TIO
LOT
LIN
E
LOT
LIN
E
LOT
LIN
E
EXIS
TIN
GW
ALK
6
5
55
55
5
EXIS
TIN
G P
ARKI
NG
AN
DIS
LAN
DS
TO R
EMAI
N
EXIS
TIN
G P
ARKI
NG
AN
DIS
LAN
DS
TO R
EMAI
N
AREA
OF
PAD
TO
BE M
OD
IFIE
D
LOT
LIN
E
TRASH
PATI
O97
4 SF
9
EXIT
ON
LY
DRIVE
THRU
24'
20'
J
J
J
J
A-19
LF-12
A-19
LF-13
A-19
LF-12
A-19
LF-12 A-19
LF-14
A-19
LF-14
A-19
LF-14
A-19
LF-17
A-19
LF-17
A-19
LF-14
LF-16LF-16
A-19
LF-12A-19
LF-13
A-19
LF-13
A-19
LF-13
S1
1
2 3 4
5
D.1D
C
BA
WP
WP
WP
- 33A1
2
2
3- 35A
WP
PANEL MS
4
A-19
LF-14
5
LF-15 LF-15
LF-16LF-16
LF-15LF-16
LF-16
LF-15
LF-16
LF-15
LF-16
LF-15LF-16
LF-16
LF-15
LF-16
LF-16
LF-16LF-16
S1S1
#10
EXISTING DEVELOPMENT SITE LIGHTING
EXISTING POLE LIGHT
PROPOSED TELEPHONE PEDISTAL
UTILITY XFMR
PROPOSED NEW PRIMARY DROP AND TRANSFOMER
S1- 23A
EXISTING DEVELOPMENT SITE LIGHTING
EXISTING DEVELOPMENT SITE LIGHTING
LF-15
EXISTING SITE LIGHTING LAYOUT SUBMITTED, APPROVED AND
CONSTRUCTION IS TO REMAIN.
LIGHTING SHOWN FOR EXITING UNLIT PORTION OF SITE. PLEASE ALSO REFER TO APPROVED SITE
LIGHTING FROM PREVIOUS DEVELOPER'S SUBMITTAL.
- 31A
EXISTING DEVELOPMENT SITE LIGHTING
EXISTING DEVELOPMENT SITE LIGHTING
EXISTING DEVELOPMENT SITE LIGHTING
LIGHT FIXTURE SCHEDULE NOTES
1. FURNISH WITH HUBBELL OUTDOOR LIGHTING SSS-H-16-40-B-1-S2-DB-UL POLE. FULL CUT OFF FIXTURE.
(PIE
R H
EIG
HT
ABO
VE
SOIL
)
h1 =
2'-0
" @ [p
arki
ng lo
t] &
0'-6
" @ [s
ide
wal
k]
(PIE
R E
MB E
DM
ENT)
L =
5'-0
"
LIGHT POLE
POLE GROUND LUG
HAND HOLE
BOLT COVER
POLE BASE
1 1/2" CHAMFER
ANCHOR BOLTS (4 THUS.)
GRADE
(6) #5 VERTICAL REBARS
#3 REBAR TIES AT 10" O.C.
POWER CONDUIT
GROUND CONDUIT
#8 GROUND IN 3/4" PVC
THERMOWELD TO 5/8" X 6'-0" GROUND ROD2" CLR
3" C
LR
11" DIA.
BASE
BASE
(4) 3/4" DIA. CAST-IN-PLACE HOOK ANCHOR BOLTS (ASTM F1554-55) [PROJECTION =3 1/2", LENGTH = 30", HOOK LENGTH = 3"]
NOTE: 1. CONCRETE TO BE 2500 PSI COMPRESSIVE STRENGTH @ 28 DAYS.2. CONCRETE SHALL HAVE A MAXIMUM WATER/CEMENT RATIO OF 0.55.3. CONCRETE SHALL BE NORMAL WEIGHT AND BE AIR ENTRAINED WITH 6% (+/-) 1.5% ENTRAINED AIR BY VOLUME @ POINT OF DISCHARGE.
ANCHOR BOLT PLAN
POLE BASE DETAIL
ANCHOR BOLT PLAN
PRO
JEC
TIO
N
LEN
GTH
HOOK LENGTH
1'-6"
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
E0.10
XXXXX
BID & PERMIT
XX-XX-XX
SITE ELECTRICALPLAN
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
ELECTRICAL PLAN NOTES
1 PROVIDE J-BOX FOR MENU BOARD. PROVIDE 2#10, #10G, 1/2"C. COORDINATEEXACT LOCATION AND MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGSAND APPROVED SIGN VENDOR SHOP DRAWINGS. CIRCUIT VIA LIGHTINGCONTROLS. RE: E2.0/LIGHTING CONTROL DIAGRAM.
2 PROVIDE J-BOX FOR DIRECTIONAL SIGNAGE. PROVIDE 2#10, #10G, 1/2"C.COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH ARCHITECTURALDRAWINGS AND APPROVED SIGN VENDOR SHOP DRAWINGS. CIRCUIT VIALIGHTING CONTROLS. RE: E2.0/LIGHTING CONTROL DIAGRAM.
3 PROVIDE J-BOX FOR PRE-ORDER MENU BOARD. PROVIDE 2#10, #10G, 1/2"C.COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH ARCHITECTURALDRAWINGS AND APPROVED SIGN VENDOR SHOP DRAWINGS. CIRCUIT VIALIGHTING CONTROLS. RE: E2.0/LIGHTING CONTROL DIAGRAM.
4 UNDERGROUND ELECTRICAL SERVICE FROM UTILITY TRANSFORMER. REFER TOCIVIL SHEETS FOR LOCATION AND ROUTING. REFER TO RISER, SHEET E5.0 FORADDITIONAL INFORMATION. VERIFY AND COORDINATE ALL REQUIREMENTS WITHUTILITY BEFORE BEGINNING WORK.
5 UNDERGROUND TELEPHONE SERVICE. PROVIDE (2) 4" CONDUITS ASCOORDINATED WITH LOCAL UTILITY COMPANY. REFER TO CIVIL SHEETS FOREXACT LOCATION AND ROUTING. VERIFY AND COORDINATE ALL REQUIREMENTSWITH UTILITY BEFORE BEGINNING WORK.
1/16" = 1'-0"1
SITE PLAN - ELECTRICAL
LIGHT FIXTURE SCHEDULE SITE LIGHTING
FXT.LTR. MANUFACTURER CAT. NO. FIXTURE DESCRIPTION
LAMP
MOUNTING REMARKSNO. WATTS TYPE
LF-12 CONTECH CYL6227KMVDUDXMCLR-B EXTERIOR - DECORATIVE SCONCE - UP AND DOWN LIGHT - BLACK 1 28 LED SCONCE - PER ARCH 2700K, 460 LUMEN, WET LOCATION
LF-13 CONTECH CYL6-2-27K-MVD-W-X-M-CLR-B EXTERIOR - DECORATIVE SCONCE - BLACK 1 14 LED SCONCE - PER ARCH 2700K, WET LOCATION
LF-14 JUNO S313L2-2K-WFL-BLK EXTERIOR - DOWNLIGHT AT ARTWORK - ALUMINUM BRONZE 1 18 LED WALL WASH 2700K, 500 LUMENS
LF-15 ECOSENSE WSH-M-27-120IC-BK-11/WSH-M-LSD-80 EXTERIOR - GRAZING SYSTEM AIMED UP AT WALL 1 50 LED SURFACE 2700K, 80 DEGREE ANGLE
LF-16 COUCH & PHILIPPI C&P DOWNLIGHT EXTERIOR - RECESSED LED LENSED CAN LIGHT - BLACK 1 10.5 LED RECESSED TO BE COORDINATED WITH AWNING VENDOR
LF-17 RAB WPLED52Y EXTERIOR - WALL PACK - BRONZE 1 52 LED SURFACE REPLACE EXISTING IF REQUIRED
S1 HUBBELL ASL-16L-4K-210-3-TYPE III SITE LIGHTING - MEDIUM SIZE 16 LED CONFIGURATION - DARK BRONZE - SSS-H SERIES POLES 1 123 LED POLE MOUNT 16' 120-277V, 4000K, 11153 LUMENS, NOTE 1
ALL LIGHT FIXTURES, EXCEPT SITE LIGHTING, TO BE FURNISHED BY OWNER, COORDINATE AS REQUIRED WITH ANDY BRUBAKER WITH CS ILLUMINATION [email protected]
FIXTURES LF-15 & LF-16 TO BE FURNISHED WITH AWNING/CANOPY WIRED BY ELECTRICAL CONTRACTOR. SUPPLIED AND INSTALLED BY CANOPY VENDOR.
REVISIONS
NO. DATE DESCRIPTION
D
J
DS
OS
TC
TS
M
LIGHT FIXTURE AND DESIGNATION. REFER TO LIGHT FIXTURE SCHEDULE FOR CHARACTERISTICS. LOWER CASE LETTER INDICATES SWITCHING.
DUPLEX RECEPTACLE. PROVIDE COMMERCIAL SPECIFICATION GRADE, GRAY, GROUNDING, THREE-WIRE TYPE WITH PARALLEL SLOTS RATED AT 20A, 120V. PASS AND SEYMOUR OR APPROVED EQUAL. PROVIDE PRESSED PLATED STEEL IN UNFINISHED AREAS. MOUNT AT 18"AFF UNLESS NOTED OTHERWISE. `GFI' DENOTES GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLES. `U' DENOTES COMBINATION USB CHARGER/RECEPTACLE SIMILAR TO NEWER TECHNOLOGY #NWTPWR2U15ATRW RECEPTACLE WITH TWO 2.5A USB PORTS COMPATABLE WITH USB 1.1/2.0/3.0 DEVICES:
a. OUTLETS TO BE GREY W/ STAINLESS STEEL COVERS, WHERE ADJACENT SURFACE IS STAINLESS STEEL.
b. OUTLETS TO BE WHITE, W/ STAINLESS STEEL COVERS, WHERE ADJACENT SURFACE IS IVORY/WHITE.
SPECIAL RECEPTACLE. PROVIDE RECEPTACLE WITH CONFIGURATION AS COORDINATED WITH EQUIPMENT AND MOUNT AS NOTED.
SINGLE POLE SWITCH AT 48"AFF OR AS NOTED. PROVIDE COMMERCIAL SPECIFICATION GRADE, QUIET TYPE, GRAY, FLUSH TOGGLE SWITCHES RATED FOR 20A, 120V PASS & SEYMOUR OR APPROVED EQUAL. PROVIDE STAINLESS STEEL DEVICE PLATES IN FINISHED AREAS, PRESSED PLATED STEEL IN UNFINISHED AREAS. WHERE MULTIPLE SWITCHES ARE INDICATED, INSTALL SINGLE COVERPLATE.
MOTOR RATED SWITCH.
TELEPHONE OUTLET 48"AFF. PROVIDE OUTLET BOXES WITH SINGLE GANG FRONT FLANGE & STAINLESS STEEL DEVICE PLATE WITH PHONE RECEPTACLE AS REQUIRED BY EQUIPMENT INSTALLER. PROVIDE 3/4" CONDUIT FROM OUTLET BOX TO ACCESSIBLE CEILING SPACE AND TERMINATE WITH BUSHING.
JUNCTION OR PULL BOXES. PROVIDE CODE GAUGE GALVANIZED STEEL BOXES WITH SCREWED OR BOLTED METAL COVERS.
COMBINATION EXIT/EMERGENCY LIGHT. REFER TO LIGHT FIXTURE SCHEDULE FOR CHARACTERISTICS.
EMERGENCY LIGHT. REFER TO LIGHT FIXTURE SCHEDULE FOR CHARACTERISTICS.
2" X 4" DATA BOX 18"AFF OR AS NOTED. WITH 3/4' CONDUIT STUBBED OUT ABOVE ACCESSIBLE CEILING SPACE. RE: E04.00/1 FOR ADDITIONAL INFORMATION.
OCCUPANCY SENSOR MODEL PW-200-W BY WATTSTOPPER OR EQUAL.
TIME CLOCK:TC-1 TO BE: INTERMATIC T101 OR APPROVED EQUAL.
TIMESWITCH:TS-1 TO BE: INTERMATIC MODEL ET70415CR OR APPROVED EQUAL.
DAYLIGHT SENSOR LUTRON RADIO POWR SAVR OR APPROVED EQUAL.
EXISTING TENANT PANEL. REFER TO PANEL SCHEDULE FOR NEW CIRCUIT BREAKER CHARACTERISTICS. NEW BREAKERS IN EXISTING PANELS SHALL HAVE INTERUPTING CAPACITITES NOT LESS THAN THE EXISTING BREAKERS TO REMAIN.
DENOTES ISOLATED GROUND RECEPTACLE
U
DENOTES COMBINATION USB CHARGER/ RECEPTACLE
ELECTRICAL SYMBOLS (SYMBOL SPEC)1. MAXIMUM SHORT CIRCUIT AVAILABLE AT THE MAIN SWITCHBOARD IS _42,000___________ AMPS SYMMETRICAL.
2. MAIN SWITCHBOARD SHALL HAVE A MINIMUM BUS BRACING OF 65KAIC
3. MAIN DISCONNECT SHALL BE PADLOCKABLE IN THE "OFF" POSITION.
4. UNLESS OTHERWISE NOTED, ALL FUSES SHALL BE CURRENT LIMITING CLASS RK1 EQUAL TO BUSS KTN-R FOR 250V DISCONNECT SWITCHES AND BUSS KTS-R FOR 480V DISCONNECT SWITCHES.
5. UNLESS OTHERWISE NOTED, ALL FUSES FOR THE PROTECTION OF MOTOR CIRCUITS SHALL BE DUAL-ELEMENT (TIME DELAY) CLASS RK5 EQUAL TO BUSS FRN-R FUSETRON FUSES FOR 250V AND BUSS FRS-R FUSES FOR 480V.
6. ALL CIRCUIT BREAKERS SHALL HAVE A MINIMUM 10,000 A.I.C. UNLESS NOTED OTHERWISE.
7. ALL FEEDER LENGTHS SHOWN ARE FOR VOLTAGE DROP CALCULATIONS ONLY. ELECTRICAL CONTRACTOR SHALL DETERMINE EXACT FEEDER LENGTH FOR HIS BID.
8. ALL SPLICES AND TERMINATIONS FOR ALUMINUM CONDUCTORS SHALL BE MADE WITH APPROVED HIGH PRESSURE TYPE FITTINGS. TERMINATION AT DEVICES WITH LUGS AS AN INTEGRAL PART OF DEVICE SHALL HAVE COPPER PIGTAILS TO ALUMINUM CONDUCTORS. THOROUGHLY COAT ALL ALUMINUM TERMINATIONS WITH APPROVED OXIDATION INHIBITOR.
9. PROVIDE A METAL CABINET AND SET OF SPARE FUSES FOR EACH SIZE AND TYPE SHOWN ON THE SINGLE LINE DIAGRAM. CABINET SHALL HAVE HINGED DOOR AND NAMEPLATE "SPARE FUSES".
10. ALL SECTIONS OF THE MAIN SWITCHBOARD SHALL BE EQUIPPED WITH MICARTA NAMEPLATES INDICATING: "CAUTION-INSTALL CURRENT LIMITING FUSES AS ORIGINALLY INSTALLED".
11. THE DISCONNECTING MEANS FOR THE F.A. CONTROL PANEL SHALL BE 10' MIN. AND 25' MAX. AWAY FROM SERVICE MAIN DISCONNECT.
12. PROVIDE CARD HOLDERS ON INSIDE OF DOORS OF PANELBOARDS FOR INDEX CARDS.
13. PROVIDE TWO (2) KEYS WITH EACH PANELBOARD.
14. SPACES IN PANELBOARDS SHALL BE FULLY BUSSED TO ACCEPT FUTURE CIRCUIT BREAKERS.
15. TOP AND BOTTOM GUTTERS SHALL BE MINIMUM 6" HIGH. PROVIDE 12" GUTTER WHERE DOUBLE LUGS ARE REQUIRED.
16. SUBMIT MAIN SWITCHBOARD SHOP DRAWINGS TO THE UTILITY COMPANY FOR THEIR REVIEW AND APPROVAL.
17. ALL PULL BOXES SIZES SMALL BE PER UTILITY CO.'S REQUIREMENTS.
18. WHERE CIRCUIT BREAKERS SUPPLY POWER TO FIXTURES, MOTORS, AND SIGNAL SYSTEMS, THE BREAKERS SHALL BE FURNISHED WITH LOCKING FACILITIES SO THAT EACH INDIVIDUAL BREAKER CAN BE LOCKED OFF WITH A PADLOCK.
19. ALL CIRCUIT BREAKERS USED TO CONTROL LIGHTING FIXTURES SHALL BE U.L. LISTED FOR SWITCHING DUTY, 'SWD'.
20. A. CONTRACTOR SHALL PROVIDE A "UFER GROUND" FOR SERVICE GROUNDING SYSTEM WHICH SHALL CONSIST OF, BUT NOT LIMITED TO:
1. 20' LENGTH OR MORE OF A COPPER CONDUCTOR (SIZED PER N.E.C. 2005. SEC.#250-52A)(3) LOCATED BELOW THE VAPOR BARRIER AND ABOUT 3" ABOVE THE BASE OF CONCRETE FOOTING. MINIMUM NO. 2 BARE COPPER CONDUCTOR ENCASES IN MINIMUM 2" OF CONCRETE. 2. ACCESSIBLE AND APPROVED GROUND CLAMPS. 3. BONDING OF COPPER CONDUCTOR TO INTERIOR METALLIC COLD WATER PIPING SYSTEM. 4. BONDING JUMPER OR SCREWS FOR NEUTRAL TERMINAL IN MAIN SWITCHBOARD, IF INSTALLED FROM THE CAN.
PROVIDE ALL REQUIRED COMPONENTS FOR A COMPLETE "UFER GROUND SYSTEM" AS APPROVED BY LOCAL INSPECTOR AND REGULATIONS, OR
B. COLD WATER PIPE GROUNDING METHOD, IF USED, SHALL BE SUPPLEMENTED BY AN ADDITIONAL GROUNDING ELECTRODE AS INDICATED BY SECTION 250-53(D). SUPPLEMENTAL ELECTRODE SHALL BE 5/8" DIAMETER X 10 FEET DRIVEN COPPER GROUND ROD BONDED TO WATER MAIN BY CONDUCTOR SIZED THE SAME AS THE SERVICE GROUND CONDUCTOR.
21. BUSES IN PANEL BOARDS, SWITCHBOARDS, SERVICES ETC., FEEDERS AND BRANCH CIRCUIT CONDUCTORS SHALL BE ALUMINUM. INSTALL NYLON PULL WIRE IN EACH SPARE CONDUIT.
22. TEMPERATURE RATING OF ALL CONDUCTOR TERMINALS SHALL BE 75 DEGREE CELSIUS.
23. FOR SWITCHBOARDS, PANELBOARDS AND EQUIPMENT CONTAINING BREAKERS, SWITCHES AND CONDUCTOR TERMINATIONS SHALL BE LISTED FOR 75 DEGREE TERMINATION WITH ALUMINUM SERVICE FEEDERS.
24. HORIZONTAL PORTION OF CONDUIT EXPOSED ON THE ROOF AND FEEDING EQUIPMENT SHALL NOT BE MORE THAN 5' UNLESS THE WRITTEN APPROVAL FROM ARCHITECT OR ENGINEER IS OBTAINED.
ELECTRICAL NOTES:
1. THE GENERAL CONDITIONS AND THE ELECTRICAL SECTION OF SPECIFICATIONS SHALL APPLY TO THIS PORTION OF WORK, IN ADDITION TO ELECTRICAL NOTES AND GENERAL NOTES STATED HEREIN.
2. REFER TO ALL THE DRAWINGS AND VISIT SITE IN ORDER TO COORINATE THE ELECTRICAL WORK WITH OTHER WORK ON THE PREMISES AND WITH FIELD CONDITIONS. THE ARCHITECTURAL AND STRUCTURAL DRAWINGS TAKE PRECEDENCE OVER THE ELECTRICAL DRAWINGS IN THE REPRESENTATION OF THE GENERAL CONSTRUCTION WORK OF THESE TRADES. REFER TO REFLECTED CEILING PLANS FOR FIXTURE LOCATION AND TO EQUIPMENT SUPPLIER DRAWINGS FOR OUTLET LOCATION.
3. WHERE THE WORK AFFECTS THE OPERATION OF EXISTING FACILITIES INCLUDE ANY PREMIUM COSTS REQUIRED TO AVOID SHUT-DOWN OF FACILITIES DURING NORMAL OPERATION.
4. PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, TRANSPORTATION, AND SERVICE REQUIRED FOR A COMPLETE AND OPERATIVE ELECTRICAL SYSTEM AS INDICATED ON DRAWINGS OF SPECIFIED.
SCOPE:
THE WORK SHALL INCLUDE: A. PROVISION OF ELECTRICAL AND TELEPHONE SERVICE. B. LIGHTING AND POWER SYSTEM. C. LIGHTING FIXTURES, LAMPS, OUTLETS, DEVICES. D. WIRING FOR HVAC. AND PLUMBING, INCLUDING CONTROLS AND CONTROL WIRING PER MECH. DRAWING. E. TELEPHONE CONDUITS AND OUTLETS. F. SHOP DRAWINGS, WIRING DIAGRAMS, EQUIPMENT DATA. G. TESTING, CLEANING, ADJUSTING. H. METAL SUPPORTS, PLYWOOD BACKINGS. I. PERMITS, INSPECTIONS, FEES. J. TEMPORARY POWER AND LIGHT FOR ELECTRICAL WORK. K. RECORD "AS BUILT" DRAWINGS. L. PANELBOARDS, TRANSFORMERS, FEEDERS ETC. M. EMERGENCY LIGHTING. N. GROUNDING, BONDING. O. PULL WIRE IN ALL EMPTY CONDUITS. P. SERVICE & EQUIPMENT GROUNDING SYSTEM..
ALL LIGHT EMITTED FROM THE BUILDING AND PARKING LOT SHALL BE CONFINED TO THE PROPERTY.
l. THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE OF THE WORK AND THOROUGHLY FAMILIARIZE HIMSELF WITH THE WORKING CONDITIONS AND THE EXACT NATURE AND EXTENT OF THE WORK TO BE DONE. TAKING INTO ACCOUNT ANY SPECIAL OR UNUSUAL FEATURES PECULIAR TO THIS JOB.
2. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY ELECTRICAL PERMIT(S) PRIOR TO JOB START AND OBTAIN PROPER INSPECTION FROM DEPARTMENT OF BUILDING AND SAFETY.
3. ALL ELECTRICAL INSTALLATION SHALL COMPLY WITH THE APPLICABLE ELECTRICAL CODE AND ENERGY CONSERVATION AND OTHER APPLICABLE ORDINANCES AND STATUES.
4. OVERCURRENT PROTECTION AND DISCONNECTING MEANS FOR ALL MOTORS SHALL BE INSTALLED TO COMPLY WITH ELECTRICAL CODE AND EQUAL TO MOTOR H.P.
5. EXACT LOCATION OF ALL EQUIPMENT SHALL BE VERIFIED IN THE FIELD AND ROUTING OF CONDUITS SHALL SUIT FIELD CONDITIONS.
6. ALL ELECTRICAL EQUIPMENT OUTDOORS SHALL BE WEATHERPROOF AND LISTED FOR THE PURPOSE.
7. IT IS THE INTENT OF THESE DRAWINGS THAT THIS BE A COMPLETE ELECTRICAL JOB. ANY ERRORS OR OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO BIDDING THE JOB.
8. CONTACT POWER AND TELEPHONE CO. AND INSTALL SERVICES AS PER UTILITY CO. REQUIREMENTS. CONTRACTOR SHALL PAY ALL FEES AND INCLUDE THEM IN HIS/HER BID.
9. THE CONTRACTOR SHALL EXAMINE THE CONTRACT PLANS IN ORDER TO LOGICALLY LOCATE WORK IN COORDINATION WITH CONSTRUCTION SUCH AS CABINETS, BEAMS, FURRING, DOOR SWINGS E.T.C.
10. CONDUITS SHALL BE CLEAN OF WATER, DEBRIS, AND OTHER FOREIGN MATERIAL PRIOR TO PULLING CONDUCTORS.
11. CONDUITS WHICH ARE INSTALLED AT THIS TIME AND LEFT EMPTY FOR FUTURE USE, INCLUDING TELEPHONE AND INTERCOMMUNICATION SYSTEM, SHALL HAVE #12 GALVANIZED PULL WIRE LEFT IN PLACE FOR FUTURE USE.
12. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER PHASING OF THE BRANCH CIRCUITS INSIDE PANELBOARD(S),
13. ALL PANELS SHALL HAVE HINGED AND LOCKABLE DOORS. INSTALL A TYPEWRITTEN DIRECTORY IN ALL PANELS.
14. ALL CONTROL WIRING FOR THE A/C AND HEATING SHALL BE OF 600V INSULATION. CABLE SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY ELECTRICAL CONTRACTOR.
15. ALL WIRING SHALL BE TYPE THHN OR THWN 600 VOLTS UNLESS NOTED OTHERWISE.
16. THERMOSTATS SHALL BE MOUNTED ON 4S x 1 1/2" DEEP J-BOX.
17. BOND ALL METALLIC GAS AND WATER PIPING FOR CONTINUITY PER N.E.C. PREVAILING EDITION.
18. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LTG. FIXTURE LOCATION.
19. CONDUITS ENTERING OR LEAVING FREEZER OR COOLER AREA SHALL BE PROVIDED WITH SEAL.
20. CONTRACTOR SHALL CONSULT WITH ARCHITECT AND KITCHEN SUPPLIER FOR EXACT LOCATIONS OF EQUIPMENTS PRIOR TO ROUGH-IN AND COORDINATE LOCATION OF OUTLETS AND SWITCHES WITH OTHER TRADES.
21. ROOF ACCESS IS PROVIDED. SEE ARCHITECTURAL PLAN.
22. CHECK WITH MECHANICAL FOR ACTUAL NO. OF CONTROL WIRE TO A/C UNIT AND TIMECLOCK. CONTRACTOR TO PROVIDE AND INSTALL TIMECLOCK AS REQUIRED BY MECHANICAL CONTRACTOR FOR A/C UNIT IN ACCORDANCE TO TITLE 24 PRIOR TO START OF WORK. ELECTRICAL CONTRACTOR SHALL VERIFY WITH A/C CONTRACTOR THE ELECTRICAL REQUIREMENTS FOR THE A/C AND HEATING SYSTEM. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NECESSARY ELECTRICAL WORK TO MAKE A COMPLETE AND OPERABLE SYSTEM. PROVIDE 1/2" C.O. FROM EACH A/C UNIT TO THERMOSTAT.
23. ALL FEEDER AND BRANCH CIRCUIT CONDUCTORS ARE BASED ON COPPER CONDUCTOR RATING.
24. CONTRACTOR SHALL BE RESPONSIBLE FOR ORDERING PROPER TYPES OF TRIM FOR ALL RECESSED FIXTURES TO FIT CEILING.
25. ALL FIXTURES SHALL BE U.L. LISTED AND APPROVED FOR THE PURPOSE.
26. ACRYLIC LENS SHALL BE 100% PURE. VIRGIN ACRYLIC.
27. ALL LIGHTING FIXTURES SHALL BE INSTALLED PER MANUFACTURERS INSTRUCTIONS.
28. RECESSED FIXTURES IN FIRE RATED CEILING OR SUPPLY AIR PLENUMS SHALL BE APPROVED FOR THE FIRE RATING OF THE CEILING. PROVIDE AIR-TIGHT GASKETS TO SEAL AROUND OPENINGS.
29. FIXTURES IN LUMINOUS CEILINGS OR CEILING CAVITIES OR SOFFITS SHALL BE APPROVED FOR TYPE OF INSTALLATION.
30. FINISH OF TRIMS OF ALL RECESSED FIXTURES SHALL MATCH CEILING FINISH AS DIRECTED BY THE ARCHITECT.
31. VERIFY LETTER SIZE AND COLOR OF INTERNALLY ILLUMINATED EXIT SIGNS WITH LOCAL AUTHORITIES PRIOR TO SUBMITAL OF SHOP DRAWINGS.
32. RECESSED FIXTURES SHALL BE PRE-WIRED TO ATTACH J-BOX IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. FIXTURES SHALL BE APPROVED FOR MAXIMUM NUMBER OF WIRES GOING IN AND OUT OF THE FIXTURE AS SHOWN ON PLANS.
33. CONTRACTOR SHALL VERIFY THE TYPE OF CEILING BEFORE ORDERING ANY FIXTURES. HE IS FULLY RESPONSIBLE TO PROVIDE ALL MOUNTING BRACKETS, CEILING CONDITIONS, AT NO EXTRA CHARGE TO THE OWNER.
34. PROVIDE GROUNDING CONDUCTOR FOR FLEXIBLE METALLIC CONDUIT SUPPLIED BY OVER 20A O.C.P. OR OVER 6 FT. IN LENGTH PER SECT. 250-118(6).
35. ALL OUTLET BOXES MUST BE SIZE PER CODE SECT. 370-6 AND 370-18. MINIMUM SIZE TO BE 4" TRADE SIZE.
36. ALL CONDUITS SHALL BE RUN CONCEALED UNLESS NOTED OTHERWISE.
37. FROM EACH PANELBOARD RECESSED IN WALLS, STUB TWO 3/4 " CONDUITS INTO ACCESSIBLE CEILING SPACE FOR FUTURE USE. LABEL 'SPARE'.
38. TERMINATE ALL TELEPHONE HOME-RUNS AT TELEPHONE BACKBOARD.
39. STEMS OF PENDANT MOUNTED FIXTURES SHALL BE APPROVED BY APPLICABLE CODES OR UL LISTED.
40. INSTALL NYLON PULL WIRE IN EACH CONDUIT, SPECIFIED AS "CONDUIT ONLY".
41. ELECTRICAL CONTRACTOR SHALL VERIFY WITH OTHER TRADES ALL ELECTRICAL CHARACTERISTICS OF EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS. CONTRACTOR SHALL VERIFY VOLTAGE, PHASE AND HORSEPOWER, AND SHALL NOTIFY ENGINEER OF ANY DISCREPENCIES PRIOR TO START OF WORK.
42. ELECTRICAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF ALL ELECTRICAL EQUIPMENT, INCLUDING EQUIPMENT SUPPLIED BY OTHER TRADES PRIOR TO ORDERING OF EQUIPMENT. ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED ONLY AFTER SHOP DRAWINGS ARE REVIEWED.
GENERAL NOTES:
1. FIXTURE CATALOG NUMBERS ARE INDICATED FOR GUIDANCE PURPOSES. ALL WRITTEN DESCRIPTION IN SPECIFICATIONS AND ON DRAWING SHALL APPLY.
2. ALL ADJUSTABLE FIXTURES SHALL BE AIMED AND ADJUSTED DURING EVENING HOURS TO THE SATISFACTION OF THE ARCHITECT.
3. ALL RECESSED FIXTURES SHALL BE COMPATIBLE WITH THE FINISH CEILING SYSTEM.
4. RECESSED INCANDESCENT FIXTURES SHALL BE PRE-WIRED TO ATTACHED JUNCTION BOX IN ACCORDANCE TO LOCAL CODE REQUIREMENTS.
5. ALL SUSPENDED FIXTURES SHALL BE STEM MOUNTED UNLESS SPECIFICALLY CALLED FOR AS CHAIN MOUNTED. SEE SPECIFICATION FOR REQUIREMENTS.
6. FIXTURES INSTALLED IN WET LOCATION SHALL BE MARKED "SUITABLE FOR WET LOCATIONS".
7. FIXTURES INSTALLED IN LUMINOUS CEILING SHALL BE APPROVED FOR THAT PURPOSE.
8. VERIFY LETTER SIZE AND COLOR OF INTERNALLY ILLUMINATED EXIT SIGN WITH LOCAL
MULTIWIRE BRANCH CIRCUITS SHALL COMPLY WITH 2011 NEC 210.4(B)
NOTES:
- ALL WORK TO COMPLY WITH THE CURRENT EDITION OF THE NEC (NFPA 70).
- THERMOSTATS AND SWITCHES INSTALLED IN AREAS EQUIPPED FOR THE DISABLED SHALL BE LOCATED AT NOT MORE THAT 48" TO TOP OF BOX FROM THE FLOOR. THE BOTTOM OF BOX FOR RECEPTACLES SHALL BE NO MORE THAN 48" OR LOWER THAN 15" TO BOTTOM OF BOX. PER A.D.A.
- ALL PANELS SHALL BE SERIES RATED AND PROPERLY IDENTIFIED PER SECTION 110-22 NEC.
- ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY.
NOTES - FIXTURE LIST:
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
E1.00
XXXXX
BID & PERMIT
XX-XX-XX
NOTES ANDSYMBOL LIST
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
REVISIONS
NO. DATE DESCRIPTION
OS
OS
OS
OSTC
J
J
J J J
J
J
J
J J
J
J
J
LED STRIP LIGHT, SEELIGHTING SPEC
A-9a
LD2
FIXTURE TYPE
PANEL SECTION
CIRCUIT
SWITCH
LIGHTING INTENSITY SHALL BE AS FOLLOWS:1. AT LEAST TEN (10) FOOT CANDLES (ONE HUNDRED EIGHT LUX) AT A DISTANCE OF THIRTY INCHES (SEVENTY FIVE CENTIMETERS) ABOVE THEFLOOR, IN WALK-IN REFRIGERATION UNITS AND DRY FOOD STORAGE AREAS AND IN OTHER AREAS AND ROOMS DURING PERIODS OF CLEANING.
2. AT LEAST TWENTY (20) FOOT CANDELS (TWO HUNDRED FIFTEEN LUX):a. AT A SURFACE WHERE FOOD IS PROVIDED FOR CONSUMER SELF-SERVICE SUCH AS BUFFETS AND SALAD BARS OR WHERE FRESH PRODUCE OR PACKAGED FOODS ARE SOLD OR OFFERED FOR CONSUMPTION;b. INSIDE EQUIPMENT SUCH AS REACH-IN AND UNDER-COUNTER REFRIGERATORS;c. AT A DISTANCE OF THIRTY INCHES (SEVENTY FIVE CENTIMETERS) ABOVE THE FLOOR IN TOILET ROOMS AND IN AREAS USED FOR HANDWASHING WAREWASHING, EQUIPMENT STORAGE, OR UTENSIL STORAGE;
3. AT LEAST FIFTY FOOT CANDLES (FIVE HUNDRED FOURTY LUX) AT A SURACE WHERE A FOOD EMPLOYEE IS WORKING WITH FOOD, UTENSILS, OREQUIPMENT SUCH AS KNIVES, SLICERS, GRINDERS, OR SAWS WHERE EMPLOYEE SAFETY IS A FACTOR. (THIS INCLUDES ANY AREAS WHERE EMPLOYEES ARE WORKING WITH FOOD AND ABOVE ICE MACHINES.)
LIGHT FIXTURES LOCATED OVER UNCOVERED EQUIPMENT MUST HAVE SHATTERPROOF BULBS AND/OR LENS COVERS.
PROVIDE SUPPORT FOR ALL LIGHT FIXTURES PER N.E.C.
A-19
LF-13
A-19
LF-13
A-19
LF-13
A-19
LF-13
A-9b
LF-1
A-9b
LF-1
A-9b
LF-1
A-9b
LF-1
A-9b
LF-1
A-3
EM1
A-1
LF-3
A-1a
LF-3
A-1a
LF-3
A-1a
LF-3
A-3
LF-3
A-1a
LF-3 A-1a
LF-3
A-1
LF-3
A-1
LF-3
A-1a
LF-3
A-3
EM1
A-5
LF-19
A-19
LF-17
A-19
LF-17
A-19
LF-14
A-19
LF-14
A-19
LF-14
A-19
LF-14
A-19
LF-16
A-19
LF-16
A-19
LF-12A-19
LF-12
A-19
LF-12
A-19
LF-12
A-3
EM1
A-3
EX1
A-1a
LF-3
A-1
LF-3
A-1a
LF-3
A-3a
LF-3
A-1a
LF-3
A-3
EX1
A-19
LF-14
1
LF-20
LF-20 22
EM2
EM2
EM2
A-7e
LF-2
A-19
LF-15
A-19
LF-15
A-19
LF-15
A-19
LF-15
A-19
LF-16
A-19
LF-16
A-19
LF-15
A-19
LF-15
A-19
LF-16
A-19
LF-16
A-19
LF-15
A-19
LF-15
A-19
LF-16
A-19
LF-16A-19
LF-16
A-19
LF-16
A-19
LF-15
- 19A
A-19
LF-16
A-19
LF-16
3
A-19
LF-15
44
55
A-3
EM1LF-20
2
67
5
A-3
EX1
A-3
EM1
A-3
EM1
A-3
EM1
A-3
EM1
A-3
EM1
5
5
5
55
5
A-3
EM1
A-7g
LF-2
A-7g
LF-2
A-7j
LF-7
A-7g
LF-2
A-7d
LF-6
A-7g
LF-2
8
A-9c
LF-11B
A-7e
LF-2
A-7e
LF-2
A-9c
LF-11A
A-9c
LF-11A
A-7d
LF-22
A-7d
LF-22
A-7d
LF-22
A-7d
LF-22
A-3
EM1
A-3
LF-2
A-3
EX1
NL
- 19A3
5
999
A-5
LF-21
A-5
LF-21
A-5
LF-21
99
5
A-3
EM1
A-3
EM1
A-9m
LF-8
A-9b
LF-1
A-7e
LF-2
A-3e
LF-2
A-9m
LF-8
A-7e
LF-2A-9b
LF-1
A-9b
LF-1
A-7e
LF-2
A-7e
LF-2
NL
- 19A
- 19A
A-9m
LF-8
A-9f
LF-10
A-9f
LF-10
A-9i
LF-5A
A-9i
LF-5A
A-9i
LF-5A
A-9i
LF-5A
A-9f
LF-10
A-9i
LF-5A
A-9i
LF-5A
A-9i
LF-5A
A-9i
LF-5A
A-9f
LF-10
A-7e
LF-2
A-7e
LF-2
A-7e
LF-2
- 19A
3
A-9b
LF-1
5
5
3
3
A-19
LF-17
A-7d
LF-22
A-9h
LF-9
A-9h
LF-9A-9h
LF-9
5
1. SEE SHEET E2 FOR LIGHTING CIRCUITS AND SWITCHING.
2. SEE FINISH SCHEDULE AND FINISH SPECIFICATION FOR INFORMATION ON CEILING MATERIALS.
3. SEE SHEET M1 FOR LOCATION AND SIZE OF HVAC EQUIPMENT.
4. CENTER EXIT SIGNS OVER DOOR OPENINGS AND CEILING FIXTURES IN GRID SPACES WHERE POSSIBLE.
5. WALK-IN COOLER FLUORESCENT LIGHTING PROVIDED & INSTALLED BY E.C.
6. SHATTER SHIELDS FOR ALL LIGHTS ABOVE FOOD PREP, WORK AND STORAGE AREAS SHALL BE PROVIDED.
7. PROVIDE A MIN. OF 12 AIR CHANGES PER HOUR VENTILATION TO ALL TOILETS,JANITOR CLOSETS W/ MOP SINKS, ANTEROOMS AND DRESSING ROOMS. IF MECHANICALLY EXHAUSTED, THE FAN IS TO BE ACTIVATED BY THE LIGHT SWITCH.
8. PROVIDE 100% MECHANICAL MAKE-UP AIR AND INTERLOCKING ELECTRICAL SWITCH.
9. ALL SWITCH PLATES TO BE STAINLESS STEEL
NOTES:
CEILING SUSPENSION SYSTEM & WIRES
SUSPENSION WIRES
CEILING MATERIAL
CEILING T-BAR
TYP. FOR EACH SIDE OF FIXTURE
ATTACH TO STRUCTURE TYP.
FIXTURE SUPPORT WIRES (DIAGONAL CORNERS)
12" OR 24"
5"
120 VAC FROM PANEL "A"
PC
LIGHTING CONTACTOR (SEE MATERIAL LIST): ASCO MODEL 917, OR APPROVED EQUAL WITH 120 VAC, 60HZ COIL, 20 AMP CONTACTS (QUANTITY AS SHOWN)
PHOTOCELL (SEE MATERIAL LIST) SHALL BE 120 VAC, 1800VA WITH INTEGRAL OFF TIME DELAY & NEMA TWISTLOCK BAE. ALR CAT #LM1000.
OUTDOOR LIGHTING BYPASS SWITCH. LOCATE IN COVER OF JF FOR LIGHTING CONTACTOR & PHOTOCELL . PROVIDE LABEL.
LC
(#3) 7 DAY TIME CLOCKTORK 24HR
(#1) 7 DAY TIME CLOCKTORK 24HR
(#2) 7 DAY TIME CLOCKTORK 24HR
DIRECTIONAL SIGNS
SPARE
EXT. MONUMENT SIGN
SPARE
EXT. MENU BD.
EXT. PREVIEW BD.
SPARE
SPARE
SPARE
SPARE
EXTERIOR LTS.
EXTERIOR LTS.
EXTERIOR LTS.
BUILDING WALL SIGNAGE
BUILDING WALL SIGNAGE
BUILDING WALL SIGNAGE
N.T.S.
A-29
A-33
A-35
A-19
A-21
A-23
A-37
A-39
A-41
A-31
T - DESIGNATES TOGGLE SWITCH
D1 - DESIGNATES 120V LINE VOLTAGE DIMMER. LUTRON NOVA/DIVA OR COMPATIBLE.
D2 - 0-10V DIMMING ONLY CONTROL. LUTRON NOVA/DIVA OR COMPATIBLE.
W - DIGITAL SWITCH WITH WIRELESS INPUT. LUTRON MAESTRO WIRELESS MRF2-8S-DV OR COMPATIBLE WITH DAYLIGHT SENSOR
COORDINATE AND VERIFY DIMMER SWITCH TYPES WITH LIGHT FIXTURES PRIOR TO ORDERING AND INSTALLING.
SET TIMERS
SITE LIGHTING: ON AT 5PM AND OFF AT 5AM
SIGNAGE: ON AT 5PM AND OFF AT 11PM
DRIVE-THRU EQUIPMENT: ON AT 10AM AND OFF AT 11PM
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
E1.10
XXXXX
BID & PERMIT
XX-XX-XX
LIGHTING PLAN
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
LIGHT FIXTURE SCHEDULE
FXT.LTR. MANUFACTURER CAT. NO. FIXTURE DESCRIPTION
LAMP
MOUNTING REMARKSNO. WATTS TYPE
EM1 DUALITE EV4D-02L COMPACT FULLY REC. EMERGENCY FIXTURE W/BATTERY PACK INCLUDED CEILING OR WALL 90 MIN. BATTERY BACK-UP, WITH EM
EM2 DUALITE EV4-0-W/EVO OUTDOOR REMOTE BLACK REMOTE EMERGENCY HEAD 1 6 INCLUDED CEILING OR WALL MOUNT FIXTURE ABOVE ACCESSIBLE CEILING WITH WEATHERPROOF REMOTE EMERGENCY HEAD
EX1 ISOLITE EUN-EM-COLOR-1C LED EXIT - EDGE LIT INCLUDED CEILING OR WALL 90 MIN. BATTERY BACK-UP
LF-1 HALO H457TATE010 / EL406927 / TL402SNS LED GIMBAL ADJUSTABLE DOWNLIGHT - 4" 1 13 LED RECESSED 2700K
LF-2 HALO PD6-10-ED010-PDM6A-827-61V-C LED GIMABL ADJUSTABLE DOWNLIGHT - 6" 1 13 LED RECESSED 2700K, 1000 LUMENS
LF-3 METALUX 24GR-LD4-48-F1-UNV-L830-CD1-U RECESSED 2'X4' LED TROFFER 1 43 LED RECESSED 3000K, 4800 LUMENS
LF-5A WAC LIGHTING MO-808-X12-BK BLACK MR16 DISPLAY SPOT LIGHT W/12" EXTENSION 1 8 LED SURFACE 3000K, 475-525 LUMES, PROVIDE WAC REMOTE TRANSFORMER
LF-6 CORE LIGHTING ALU-SF-78-CL-LSM45-WW-PF-24/PSDM-24V LED ACCENT DECORATIVE STRIP LIGHTING 1 4/LF LED SURFACE 2700K, WARM WHITE, 300 LUMENS
LF-7 ECOSENSE L35-I-48-06-27-80-MULT-120 LINEAR SURFACE MENU BOARD LIGHTING 1 6 LED SURFACE 3000K, 500 LM/FT
LF-8 CURREY & COMPANY EARTHSHINE PENDANT 9782 22" DIAMETER WROUGHT IRON - BLACKENED STEEL 1 18.5 LED PENDANT - PER ARCH 2700K, 84" AFF - OVER CENTER OF TABLE, VERIFY
LF-9 ARCHIPELAGO LIGHTING SST-800 SINGLE PENDANTS BY SUNSET DESIGNS 8 10 LED PENDANT - PER ARCH 2200K, 300 LUMEN, 84" AFF
LF-10 CURREY & COMPANY TRUBINA PENDANT 9861 5" DIAMETER WROUGHT IRON - HIROSHI GRAY 1 9 LED PENDANT - PER ARCH 2700K, 800 LUMEN, 84" AFF - OVER CENTER OF TABLE, VERIFY
LF-11A VARALUZ MASQUERADE 149M01SG 5" DIAMETER - STATUE GARDEN 1 9 LED PENDANT - PER ARCH 2700K, 800 LUMEN, 84" AFF
LF-11B VARALUZ MASQUERADE 149P0ISG 9" DIAMETER - STATUE GARDEN 1 9 LED PENDANT - PER ARCH 2700K, 800 LUMEN, 80" AFF
LF-19 METALUX SSF-232-UNV-EB81 SURFACE MOUNTED STRIP LIGHT 2 32 F32T8 SPX35 SURFACE UNV, ELECTRONIC BALLAST
LF-20 COLUMBIA LXEM4-40ML-RA-EU EXTREME ENVIORNMENT LENSED AND GASKETED FIXTURE 1 47 LED RECESSED 3000K, 114 LUMENS/WATT
LF-21 HE WILLIAMS LT-22-L43-AF-DRV-120 RECESSED 2'X2' LED TROFFER 1 41 LED RECESSED 3000K, 4300 LUMENS
LF-22 CORE LIGHTING ALP80-CC-FR-LSM45-2700K-24V-REM-SM SURFACE MOUNTED 6' STRIP LIGHT 1 1.5/LF LED SURFACE 2700K, 24V, DIMMABLE
PLAN NOTES
1 PROVIDE 120V POWER FOR WALK-IN COOLER LIGHTS AND DOOR HEATER. COORDINATE INSTALLATIONWITH COOLER INSTALLER. PROVIDE APPROVED MATERIAL SEALANT IN CONDUIT AT COOLERPENATRATIONS PER NEC 300.7 TO PREVENT CIRCULATION OF WARM AIR TO THE COLDER SECTION.
2 LIGHTS IN COOLER PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR.
3 ELECTRICAL CONTRACTOR TO INSTALL J-BOX ON THE INSIDE OF THE EXTERIOR WALL ABOVE FINISHEDCEILING WITH 120V CIRCUIT INDICATED. LOCATE J-BOX ON THE CENTERLINE OF THE CANOPY AND MAKEUP CONNECTIONS TO PREWIRED CANOPY LIGHTING AS COORDINATED WITH INSTALLER. CANOPY TO BEFURNISHED TO SITE PREWIRED WITH FIXTURES INSTALLED.
4 OCCUPANCY SENSOR FOR AUTOMATIC CONTROL OF TOILET LIGHTING. (WATTSTOPPER MODEL PW-200-W)
5 EMERGENCY OR NIGHT LIGHT ON UNSWITCHED CIRCUIT.
6 PROVIDE TIMECLOCK FOR SITE AND EXTERIOR LIGHTING. TIMECLOCK SHALL BE SIMILAR TO INTERMATICET9000 FOR 365 DAY ASTRONOMICAL CONTROL. CONTACTOR SHALL BE ELECTRICALLY HELD IN NEMA 1ENCLOSURE. LOCATE TIMECLOCK AND CONTACTOR NEAR ELECTRICAL PANELS.
7 LOCATION OF SWITCH BANK WITH DIMMERS. SEE DETAILS THIS SHEET.
8 UNDER COUNTER LIGHTING. REFER TO ARCHITECTURAL PLANS FOR DETAILS.
9 RECESSED J-BOX AS COORDINATED WITH VENDOR SHOP DRAWING. CONNECT TO LIGHT FIXTUREFURNISHED AND INSTALLED BY VENDOR.
3/16" = 1'-0"2
FIRST FLOOR - LIGHTING
NOT TO SCALELIGHTING FIXTURE MOUNTING DETAIL
NOT TO SCALELIGHTING CONTROL DIAGRAM
SWITCH SCHEDULE
SWITCHLABEL SWITCH AREA
SWITCHTYPE
A KITCHEN LIGHTING D2
B DISPLAY LIGHTING D2
C GENERAL LIGHTING D2
D LINEAR LIGHTING D2
E GENERAL LIGHTING D2
F PENDANT LIGHTING D1
G COUNTER DOWNLIGHTS D2
H PENDANT LIGHTING D1
I SPOT LIGHTING D1
J MENUBOARD D2
NOT TO SCALE3
ORDER COUNTER - LIGHTING DETAIL
USE #10 CONDUCTORS FOR EXTERIOR WIRING
ALL LIGHT FIXTURES, EXCEPT SITE LIGHTING, TO BE FURNISHED BY OWNER, COORDINATE AS REQUIRED WITH JASON SPRENGER WITH CS ILLUMINATION [email protected]
REFER TO SHEET E-6 FOR EXTERIOR FIXTURES
LF-9 FIXTURE BULBS TO BE HUNG BY CORD WITH CEILING HOOKS MOUNTED TO THE CEILING GRID. COORDINATE EXACT INSTALLATION IN FIELD.
REVISIONS
NO. DATE DESCRIPTION
2424
2436
W/H
S2442
F
S2424
S2424
JW
TEA
2424
2424
S1424
S2448
S2448
S2448
2436
G
+18
+18
C
GF
CI
GF
CI
GF
CI
GF
CI
GFCIGFCI JJ
+96GFCI
C
GF
CI
GF
CI
GF
CI
+74
GFCI
GF
CI
GF
CI
GF
CI
GF
CI
GFCIJ
GFCI
GFCI GFCIGFCI GFCI GFCIGFCI
J
JJ
GF
CI
GF
CI
GF
CI
GF
CI
J
JTB *
C
GF
CI
J
+102
J
J
3
3
J
MTC
AS
J
+18 +18
GFCI
GF
CI
BF
-GF
CI
BF
-GF
CI
GFCI
+74
+72"-
GF
CI
+48"-GFCI
PANEL C
PANEL K
PANEL A
PANEL B
- 17A
- 15A
- 13A
- 18B
- 28A
- 30A
P029
P029
4" CONDUIT CHASE FROM 6" ABOVE CEILING DOWN TO 72" AFF TO ACCOMMODATE ICE MACHINE REFRIGERATION SET TO REMOTE CONDENSOR. PROVIDE LONG SWEEP ELBOW, CUT FLUSH WITH FINISHED WALL.
4" CONDUIT CHASE FROM 6" ABOVE CEILING DOWN TO 12" AFF TO ACCOMMODATE BEVERAGE LINES. PROVIDE LONG SWEEP ELBOW, CUT FLUSH WITH FINISHED WALL.
- 23B - 21B
- 38,40BP137
P100P100P098B
2 3 4
D.1
D
C
B
A
P042 - 27B
- 16B
SECURITY MONITOR
2" C. THROUGH WALL FOR POS LINES TO ABOVE CEILIING POS DROP
1" CONDUIT TO SINGLE GANG AT 18" AFF
PANEL MS
P029
- 5B P076
P026
P027
- 4B
- 2B
P055
P115-1
- 29B
1" CONDUIT FOR POS
1" CONDUIT FOR COMM
P029- 14A
- 18A
P063P063
P097
P028A
- 7B
- 9B
- 11B
- 16A
P029
1" CONDUIT FOR POS
P007
- 20B
P043
P029-4
P064
- 19B- 11A
- 26B
- 12B- 10B - 6B - 14B
P050
P047
P048 P117A
P133- 22BIN CEILING
3" CONDUIT TO CEILING FOR REF. LINES
- 31,33B
P018
3#10, 1/2" C.30A, 2P, 25" AFF
3#10, 1/2" C.30A, 2P, 25" AFF
P135- 25BP135A
4" CONDUIT IN CEILING FOR BEVERAGE LINES MINIMUM 24" SWEEPS AT EACH END (IF REQUIRED BY CODE)
P015- 13B
- 15B
JBOX IN CEILING FOR SECURITY
MOUNTED ABOVE CEILING DOOR BELL XFMR
12" BELOW CEILING DOOR BELL
BUG LIGHT 18" BELOW CEILING MOUNTED HORIZONTAL
1"TT"
- 38A
IRR. CONTR.
- 36A
- 2A
- 4A
- 6A
- 8A
- 12A
- 10A
ON WALL
FOR SECURITY+90" NEXT TO POS POWER
C. FOR POSC. FOR VIDEOC. FOR MUSICC. FOR ALARM
P060
P062
P061
P029-2
P029-2
P029-2
P029-2
P029-2
P006
P095
- 24B
IN CEILING
P132
- 37B
- 41BTO EF-4
P029-4
IN CEILING
BUG LIGHT 18" BELOW CEILING MOUNTED HORIZONTAL
P055
B - 30B - 28
P033
22
22
2
2
- 32AELECTRIAN TO PROVIDE TIMECLOCK. COORDINATE CIRC PUMP INSTALL WITH PLUMBER.
CIRC PUMP PROVIDE 2#12, #12G., 1/2"C.
AQUASTAT PROVIDED BY PLUMBER
20A MOTOR RATED SWITCH
SERVICE LINE BUNDLE ABOVE CEILING
1/2" C. FOR ALARM AT 24" AFF
(2) 1" C. FOR POS AT 24" AFF
1/2" C. TO SECURITY KEYPAD AT 54" AFF HORIZONTAL
1" C. FOR SECURITY WINDOW CONTACT/PANIC
1" C. FOR POS AT 24" AFF
1" C. FOR (2) POS AT 24" AFF.
1" C. AT 26" O.C.
POS PRINTER 1" C. AT 24" AFF
1-1/2" C. FOR DRIVE THRU MENU BOARD AND 1-1/2" C. UNDERGROUND TO MENU BOARD LOCATIONS
P044
- 26A
- 24A
- 38C
4' - 9" 7' - 10"
8' -
0"4'
- 6"
3' -
11"
BUG LIGHT 18" BELOW CEILING MOUNTED HORIZONTAL
- 2,4,6C4#3, #8G., 1-1/4"C.
3
PROVIDE ISOLATED QUAD OUTLET AT 48" AFF FOR TELEPHONE EQUIPMENT, PROVIDE 48"x48"x3/4" PLYWOOD TELEPHONE BOARD. PROVIDE ADDITIONAL #8 ISOLATED G. TO SERVICE GROUND.P118A
- 42B
P029-2 +48" HOLDING CAB RESET
FRYER RESETIN CEILING
P115-1
P131
P029-4
IN CEILING
P095
P055- 40C
UP TO B - 35
S010
- 1B
C - 42
P064
- 41C
ON
- 18B
P044A
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
ALL WORK SHALL BE DONE IN ACCORDANCE WITH LOCAL BUILDING CODE, NATIONAL ELECTRICAL CODE, NATIONAL FIRE PROTECTION CODE, EPA REGULATIONS, AMERICANS WITH DISABILITIES ACT MINIMUM CONSTRUCTION STANDARDS AND OCCUPATIONAL SAFETY AND HEALTH ACT.
CONTRACTOR SHALL INCLUDE ALL PERMITS, LABOR, PLANT MATERIAL, AND EQUIPMENT TO PROVIDE FIRST CLASS AND COMPLETE INSTALLATIONS, AND ALL MATERIAL AND EQUIPMENT SHALL BE NEW UNLESS OTHERWISE SPECIFIED.
CONTRACTOR SHALL COORDINATE ROUGH-IN REQUIREMENTS AND FINAL CONNECTIONS TO KITCHEN EQUIPMENT WITH KITCHEN EQUIPMENT SUPPLIER. INSTALLATION SHALL MEET ALL CODES AND BE IN ACCORDANCE WITH EQUIPMENT MANUFACTURER'S RECOMMENDATIONS. VERIFY AND PROVIDE AS REQUIRED ALL DISCONNECTING MEANS, OVERLOAD PROTECTION, GROUNDING, ETC. TO ASSURE PROPER INSTALLATION.
CONTRACTOR SHALL PROTECT ALL EXISTING WORK TO REMAIN, AND SHALL REPAIR ANY DAMAGE INCIDENTAL TO PERFORMANCE OF NEW WORK. INTERFERENCE WITH OWNER'S OPERATIONS OR INTERRUPTION OF SERVICES SHALL BE KEPT TO A MINIMUM AND FULLY COORDINATED WITH OWNER AND UTILITY AS APPLICABLE.
UNLESS SPECIFIED OR DIRECTED BY OWNER OTHERWISE, ALL EXISTING MATERIAL AND EQUIPMENT SHOWN OR REQUIRED TO BE REMOVED FROM EXISTING CONSTRUCTION AND NOT SHOWN TO BE REUSED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE PROMPTLY REMOVED FROM THE SITE.
ACCEPTANCE OF WORK SHALL BE SUBJECT TO OWNER'S REPRESENTATIVE APPROVAL OF WORK IN PLACE AS WELL AS SHOP DRAWINGS AND SAMPLES OF MATERIALS AND EQUIPMENT WHICH SHALL BE CHECKED BY CONTRACTOR BEFORE SUBMITTAL.
CONTRACTOR SHALL SUBMIT MARKED-UP CLEAN PRINTS OF AS-BUILT CONDITIONS SHOWING CONCEALED DEVIATIONS FROM DESIGN.
CONTRACTOR SHALL KEEP PREMISES OF WORK AREA CLEAN DAILY, BROOM CLEAN AT PROJECT COMPLETION, AND SHALL REMOVE ALL REFUSE FROM SITE.
CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH EXISTING CONDITIONS BEFORE STARTING NEW WORK. CONCEALED CONDITIONS SHALL BE ADDRESSED WITH DUE CAUTION SUCH THAT UTILITIES AND SYSTEMS ARE PROTECTED.
CONTRACTOR SHALL CUT AND PATCH HOLES IN EXISTING CONSTRUCTION AS REQUIRED FOR NEW WORK WITH DUE CAUTION SUCH THAT STRUCTURAL INTEGRITY IS MAINTAINED WITHOUT IMPAIRMENT.
CONTRACTOR SHALL WARRANTY ALL NEW WORK FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTABLE AND SHALL REPAIR OR REPLACE ANY DEFECTIVE WORK INCLUDING MATERIAL, LABOR AND EQUIPMENT AT NO ADDITIONAL COST TO THE OWNER.
ALL WORK SHOWN ON DRAWINGS IS IN PART SCHEMATIC INTENDED TO CONVEY SCOPE OF WORK AND GENERAL LAYOUT. VERIFY ALL EXISTING CONDITIONS AND MAKE ADJUSTMENTS AS REQUIRED.
GENERAL ELECTRICAL REQUIREMENTS
TO OTHER RELAYS, AS REQUIRED.
NOTE:MOUNT RELAYS IN FLUSH NEMA 1 CABINET.
SNAP-ACTION SWITCH. FURNISHED WITH FIRE SUPPRESSION SYSTEM.
120 VOLT, 20 AMP CONTROL CIRCUIT
N
H
MANUAL RESET RELAY. FURNISHED WITH FIRE SUPPRESSION SYSTE..
INTERNAL WIRING. (TYPICAL)
K1
K1b
K1aPB
MAGNETICALLY HELD RELAYS SEE PLANS FOR NO. OF POLES REQUIRED.
C
C
NOTE:ALL 125-VOLT, SINGLE PHASE, 15 AND 20 A RECEPTACLES INSTALLED IN COMMERCIAL KITCHENS SHALL HAVE GHROUND FAULT INTERRUPTER PROTECTION FOR PERSONNEL. PER NEC SECTION 210-8 (B)(2)
NOTE:CONDUIT ENTERING AND LEAVING WALK-IN COOLER AND WALK-IN FREEZER AREA SHALL BE SEALED PER NEC SECTION 300.7(A) SHALL HAVE EXPANSION FITTINGS PER NEC SECTION 300.7(B)
NOTE:
REFER TO SHEET E1.70 FOR LOCATION AND ELEVATION OF RECEPTACLES LOCATED IN OFFICE.
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
E1.20
XXXXX
BID & PERMIT
XX-XX-XX
POWER PLAN
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
1/4" = 1'-0"1
FIRST FLOOR - POWER
ELECTRICAL PLAN NOTES
1 MAINTAIN NEC REQUIRED 36" MINIMUM CLEARANCE IN FRONT OF ELECTRICALPANELS.
2 MOUNT RECEPTACLES FLUSH IN CEILING OR ABOVE WINDOW. OUTLET SHALL BEWITHING 18" OF TOP OF WINDOW. CIRCUIT VIA TIME CLOCK.
3 CONNECT TO ELECTRICAL PANEL FURNISHED AND INSTALLED BY EQUIPMENTFABRICATOR.
NOT TO SCALE2
HOOD FIRE SYSTEM INTERLOCK DETAIL
REVISIONS
NO. DATE DESCRIPTION
WP-GFCI
WP-GFCI
S D
S D
S D
J
J
J
J
WP-GFCI
2 3 4
D.1
D
C
B
A
RT
1
KF
3
KF
1
KF
2
EF
1
RT
2
- 6MS
- 5MS
- 4MS
100A/3P, WP80A FUSES
30A/3P, WP30A FUSES
100A/3P, WP80A FUSES
30A/3P, WP30A FUSES
30A/3P, WP30A FUSES
30A/3P, WP20A FUSES
30A/1P, WP20A FUSES
- 41A
- 39A
- 37A
- 20A
- 7,9,11C
- 1,3,5C
- 26,28,30C
C-35
- 35B
B - 41
PROVIDE 3#12, #12G., 1/2"C.
PROVIDE 3#10, #10G., 1/2"C.
PROVIDE 3#10, #10G., 1/2"C.
1
2
2
2
2
3
4
4
4
5
5
5
1
30A/3P,WP20A FUSES
PROVIDE 3#12, #12G., 1/2"C.
- 19,21,23C
P033A
DOWN TOB - 35
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
E1.40
XXXXX
BID & PERMIT
XX-XX-XX
ROOF POWERPLAN
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
ELECTRICAL PLAN NOTES
1 WEATHERPROOF GFCI RECEPTACLE WITH IN USE COVERPLATE, CIRCUITED TOPANEL DESIGNATED. COORDINATE INSTALLATION WITH MECHANICALCONTRACTOR.
2 PROVIDE J-BOX FOR BUILDING SIGNAGE. PROVIDE 2#12, #12G, 1/2"C. COORDINATEEXACT LOCATION AND MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS ANDAPPROVED SIGN VENDOR SHOP DRAWINGS. CIRCUIT VIA LIGHTING CONTROLS. RE:E2.0/LIGHTING CONTROL DIAGRAM.
3 EXHAUST FAN EF-1 TO BE INTERLOCKED WITH RT-1. PROVIDE CONTROL WIRING ASREQUIRED AND COORDINATE INSTALLATION WITH MECHANICAL CONTRACTOR.
4 EXHAUST FAN TO BE INTERLOCKED WITH RT-1, RT-2, AND RT-3. PROVIDE CONTROLWIRING AS REQUIRED AND COORDINATE INSTALLATION WITH MECHANICALCONTRACTOR.
5 PROVIDE 2#12, #12G. FOR DUCT DETECTOR CIRCUIT AS INDICATED ON PLANS.PROVIDE CONTROL WIRING AS REQUIRED AND COORDINATE INSTALLATION WITHMECHANICAL CONTRACTOR.
1/4" = 1'-0"1
ROOF PLAN - POWER
REVISIONS
NO. DATE DESCRIPTION
PANEL A
PANEL B
PANEL C
M
NEW PANELS 'A', 'B', & 'C'
600A3P65KAICT
600 AMP, 120/208V, 3PH, 4W BUS BRACED @ 65 KAIC.
F F
TYPE"ED"200A3P
F
TYPE"ED"200A3P
TYPE"ED"200A3P
COLD WATER PIPE WITHN 5' OF BUILDING ENTRANCEGAS SYSTEM
UNDERGROUND TO BUILDING FOUNDATION STEEL 'UFFER'
(2 SETS) 4#350MCM, #4G., 4"C. TO POWER COMPANY XFMR
TYPE"FD"80A3P
TYPE"FD"80A3P
TYPE"FD"30A3P
#3/0 BARE COPPER
METER & MAIN SW. BD. "MS"W.P. NEMA 3R CABINET
AVAILABLE FAULT CURRENT = 42,000 AIC"MS" BRACED FOR 65,000 AIC
NEW NEMA 3R
RT-1
NEW NEMA 3R
RT-2
NEW NEMA 3R
RT-3
100AS3P80AFW.P.
100AS3P80AFW.P.
30AS3P30AFW.P.
1 2 3 4 5 6
4#3/
0, #
6G.,
2"C
.
3#4,
#8G
., 1"
C.
4#3/
0, #
6G.,
2"C
.
4#3/
0, #
6G.,
2"C
.
3#4,
#8G
., 1"
C.
3#10
, #10
G.,
1/2"
C.
#6 I.
G.
120V
N
A
365 DAY/HOLIDAY PROGRAMMABLE TIME CLOCK
TCS1
2 HR TIMER WITH PILOT LIGHT
20 AMP LIGHTING CONTACTOR
C1
PANEL A
TO LIGHTING
1 5 7 9
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
E1.50
XXXXX
BID & PERMIT
XX-XX-XX
SINGLE LINEDIAGRAM
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE
(1) INTERLOCK KF-2, KF-1, KF-3, AND MAU-1 UNITS. SEE MECH & CAPTIVE AIRE DWGS(3) INTERLOCK MUA-1 & AC-1; MAU-1 & AC-2 UNITS. SEE MECH DWGS.(4) GFCI CIRCUIT BREAKER(5) PROVICE LOCK-ON-DEVICE
Notes:
C 12522 W
B 13587 W EMD 33.4 kW
A 15877 W TCL 42.0 kW
41 P064 HOLDING CAB 20 1 1060 450 1 20 P122A DRAWER WARMER 42
39 SPARE 20 1 0 1900 1 20 P055 MICROWAVE (4) 40
37 SPARE 20 1 0 1900 1 20 P055 MICROWAVE (4) 38
35 SMOKE DETECTOR 20 1 300 1130 36
33 SPACE -- -- 0 1130 34
31 SPACE -- -- 0 1130
3 20 MAU-1 (1)
32
29 SPACE -- -- 0 228 30
27 SPACE -- -- 0 228 28
25 SPACE -- -- 0 228
3 20 KF-3
26
23 1140 0 -- -- SPACE 24
21 1140 0 -- -- SPACE 22
19
20 3
1140 0 -- -- SPACE 20
17 SPARE 20 1 0 0 -- -- SPACE 18
15 SPARE 20 1 0 0 -- -- SPACE 16
13 SPARE 20 1 0 0 -- -- SPACE 14
11 2252 0 -- -- SPACE 12
9 2252 0 -- -- SPACE 10
7
KF-1 (1) 30 3
2252 0 -- -- SPACE 8
5 2252 3710 6
3 2252 4685 4
1
KF-2 (1)(3) 30 3
2252 6975
3 100 PANEL K
2
CKT Circuit Description Trip Pole
A B C
Pole Trip Circuit Description CKT
FAULT... 10,000 AIC MAIN: MLO
PHASE: 3 WIRE: 4 C BUS: 225 A
VOLTAGE: 120/208 Wye PANELBOARD: MOUNTING: RECESSED
(1) PROVIDE LOCK-ON-DEVICE(3) PROVIDE RELAY CONTROLLED BY ASTRONOMICAL TIME CLOCK(4) PROVIDE RELAY CONTROLLED BT TIME CLOCK FOR MENU LIGHT ONLY(5) PROVE SHUT-OFF LTG. SHUT-OFF CONTROL DIAGRAM BELOW
Notes:
C 13857 W
B 11528 W EMD 39.2 kW
A 13441 W TCL 38.8 kW
41 EXT. SIGN (1)(3) 20 1 1200 0 -- -- SPACE 42
39 EXT. SIGN (1)(3) 20 1 1200 0 -- -- SPACE 40
37 EXT. SIGN (1)(3) 20 1 1200 360 1 20 "TT" TEL. 38
35 PRE-ORDER BOARD (1)(3) 20 1 1200 1000 1 20 IRR. CONTROLLER 36
33 MENU BOARD 20 1 1200 500 1 20 ANSUL SYSTEM (1) 34
31 DIRECTIONAL SIGNAGE (1)(3) 20 1 1200 300 1 20 CIRC PUMP 32
29 MONUMENT SIGN (1)(3) 20 1 600 1200 1 20 P029-1 ISO. GRND. (1) 30
27 SPARE 20 1 0 1200 1 20 P029-1 ISO. GRND. (1) 28
25 SPARE 20 1 0 540 1 20 TV 26
23 SITE LIGHTING 20 1 505 400 1 20 CLG MONITORS 24
21 SITE LIGHTING 20 1 303 0 1 20 SPARE 22
19 SITE LIGHTING 20 1 1003 1200 1 20 EXT. SIGN (1)(2) 20
17 SHOW WINDOW 20 1 3400 1200 1 20 P063 D/T COMM 18
15 SHOW WINDOW 20 1 2800 1200 1 20 P029-1, P029-2 (1) 16
13 SHOW WINDOW 20 1 3300 1200 1 20 P029-1, P029-2 (1) 14
11 P029-4 ISO. GRND. (1) 20 1 400 1200 1 20 ALARM ISO GRND (1) 12
9 GENERAL LIGHTING 20 1 257 1200 1 20 COMP ISO GRND (1) 10
7 GENERAL LIGHTING (5) 20 1 630 900 1 20 MANAGERS OUTLETS 8
5 RESTROOM LIGHTING 20 1 352 1200 1 20 VIDEO 6
3 EM & NIGHT LIGHTING (1) 20 1 469 1200 1 20 MUSIC 4
1 KITCHEN LIGHTING (5) 20 1 1248 360 1 20 FASTTRACK (1) 2
CKT Circuit Description Trip Pole
A B C
Pole Trip Circuit Description CKT
FAULT... 10,000 AIC MAIN: MLO
PHASE: 3 WIRE: 4 A BUS: 225 A
VOLTAGE: 120/208 Wye PANELBOARD: MOUNTING: RECESSED
(1) INDICATES HANDLE LOCKS(2) CIRCUIT VIA TIME CLOCK(3) HACR CIRCUIT BREAKER
Notes:
C 13870 W
B 11210 W EMD 26.1 kW
A 12710 W TCL 37.8 kW
41 EF-1 20 1 500 720 1 20 P118A REACH-IN REFRIGERATOR 42
39 SHUNT TRIP -- -- 0 1040 40
37 P131, P132 TIMER 20 1 700 10402 20 P137-1 ICE MACHINE
38
35 ROOF RECEPTS 20 1 540 0 1 20 SPARE 36
33 1650 0 1 20 SPARE 34
31P018 ICE MACHINE 30 2
1650 0 1 20 SPARE 32
29 P155-1 REFR. COLD PAN 20 1 1200 1200 1 20 P033 LTS, FAN 30
27 P042, P043 U.C. REFR. 20 1 500 1200 1 20 P033 LTS, FAN 28
25 P135, P135A 20 1 1340 500 1 20 P043 U.C. REFR. 26
23 P098B DUAL BREWER 20 1 1800 600 1 20 HOOD CONTROLS 24
21 P100 BEV STATION 20 1 1200 1200 1 20 P095, P133, LTS 22
19 P064 HOLDING CAB 20 1 1060 930 1 20 P006, P007 AIR CUR 20
17 SPACE -- -- 0 1260 1 20 OUTL., BUG LIGHT 18
15 P015 CARBONATOR 20 1 540 1000 1 20 SECURITY 16
13 COKE CARBONATOR 20 1 1000 1200 1 20 P117A FREEZER 14
11 P028A WORK TABLE 20 1 1800 1200 1 20 P050 U.C. FREEZER 12
9 S.C. 20 1 840 1200 1 20 P047A FRY DUMP 10
7 P097 D/T BEV. DISP. 20 1 1200 0 -- -- SHUNT TRIP 8
5 P076 HOT WATER 20 1 1850 1200 1 20 P048 6
3 SHUNT TRIP -- -- 0 840 1 20 P026 GRINDER 4
1 S010 PREP TABLE 20 1 960 1130 1 20 P027 PROCESSOR 2
CKT Circuit Description Trip Pole
A B C
Pole Trip Circuit Description CKT
FAULT... 10,000 AIC MAIN: MLO
PHASE: 3 WIRE: 4 B BUS: 225 A
VOLTAGE: 120/208 Wye PANELBOARD: MOUNTING: RECESSED
NOT TO SCALE1
SINGLE LINE DIAGRAM
PANELBOARD 'MS' ELECTRICAL LOAD SUMMARY
CIRCUIT TYPECONNECTED
LOAD DEMAND FACTOR DEMAND LOAD
LIGHTING 6,620 VA 1.25 8,275 VA
SHOW WINDOW 9,500 VA 45 FT @ 200 W/LF 9,000 VA
RECEPTACLES 1,260 VA 1.0 1,260 VA
SIGN 9,000 VA 1.25 11,250 VA
KITCHEN EQUIP 69,834 VA 0.65 45,392 VA
HVAC(LARGEST MOTOR @1.25%,REMAINING 100% PER 430-24)
72,873 VA SEE NOTE 72,873 VA
WATER HEATER 300 VA 1.0 300 VA
MISC. 8,720 VA 1.0 8,720 VA
TOTAL KVA 178.1 kVA 157.1 kVA
TOTAL AMPERES 495.0 A @208V, 3PH 436.5 A
NOT TO SCALELTG. SHUT OFF CONTROL DIAGRAM
(PROVIDE WITH ISOLATED GROUNDED BUSS)ALL 20 A KITCHEN RECEPTACLES TO BE FED THROUGH LEVITON GFRBF-KW BLANK FACE GFCI RECEPTACLE PLACED IN A FIELD LOCATED ACCESSIBLE LOCATION
REVISIONS
NO. DATE DESCRIPTION
MTC
AS
BF
-GF
CI
+72"-
GF
CI
PANEL A
PANEL B
PANEL C
VIEW D
VIEW C
VIEW B
VIEW A
2' -
6"
2' -
0"
5' -
6"
2' -
6"
5' -
6"
0' -
6"
1/2" CONDUIT STUB ABOVE LID FOR SECURITY-ADT
SINGLE COMMUNICATIONS CHASE
DOUBLE GANG P-RING
1" CONDUIT TO MENU LOOP AT O/T WINDOW
1-1/2" CONDUIT TO MENU BOARD
(2) DUPLEX
1" CHASE
D/T COMMUNICATION SINGLE GANG P-RING
1" CHASE
DUPLEX - MOUNT HORIZONTAL
1" CONDUIT STUB ABOVE LID FOR POS
1" CONDUIT STUB ABOVE LID FOR ADT WINDOW CONTACT
2" CONDUIT STUB ABOVE LID FOR COMMUNICATIONS
A
FILE CABINETSAFE
A - 8
QUAD A - 4
A - 6
A - 8
MAIN
(3) 1" CONDUIT AT 48" AFF FOR DSL, FAX, AND CREDIT CARD
POS POWER ISO GROUND DED CIRCUIT A - 10 AT 48" AND 90"
OFF
ICE
DB
U
DSL
COMPUTERMONITOR
CPU
DESKJET
FAX MACHINE
MUSIC VOLUME CONTROL
1" CONDUITSOUND RECEIVER
1' -
4"
A
SHELF
(2) 1" CONDUIT AT 42" AFF FOR MAIN AND FAX
POS CABINET
COMPUTER MONITOR
A - 2
CPU
FAX MACHINE
B
2" CONDUIT2" CONDUIT
HMETSP
HME CU
HMEUPS
SWITCH TO 1" CONDUIT
1" CONDUIT
HME EOS
SINGLE GANG MUD RING BEHIND CU
SINGLE GANG MUD RING BEHIND EOS
SECURITY MONITOR
SECURITYCAMERA
DESKJET
POS CABINET
SECURITY PHONE
SECURITY ALARMCONTROL PANEL
C
1" CONDUIT
DUPLEX A - 2B-16
1" CONDUIT STUBABOVE LID
SECURITYMONITOR
PANEL B PANEL C PANEL A
SAFE
CABINET
A - 8
THERMOSTATS
D
MUSIC VOLUME CONTROL
SOUND RECEIVER
1100 Main StreetSuite 2200Kansas City, Missouri 64105
Phone : 816-842-7552Fax : 816-842-1302
DRAWINGS & SPECIFICATIONS REMAIN THE PROPERTY OF THE DESIGN PROFESSIONAL. COPIES OF THE DRAWINGS & SPECIFICATIONS RETAINED BY THE CLIENT MAY BE UTILIZED ONLY FOR THEIR USE & FOR OCCUPYING THE PROJECT FOR WHICH THEY WERE PREPARED & NOT FOR CONSTRUCTION OF ANY OTHER PROJECT.
PROJECT #
SHEET NUMBER
E1.70
XXXXX
BID & PERMIT
XX-XX-XX
ELEVATIONS ANDDATA PLAN
EL P
OLL
O L
OC
O29
95 P
RO
TOTY
PEAD
DR
ESS
CIT
Y, S
TATE
, ZIP
CO
DE 3/4" = 1'-0"
5FIRST FLOOR - ENLARGED OFFICE
NOT TO SCALE1
DRIVE THRU
NOT TO SCALE2
MANAGER'S OFFICE A NOT TO SCALE3
MANAGER'S OFFICE BNOT TO SCALE
4MANAGER'S OFFICE C
NOT TO SCALE6
MANAGER'S OFFICE D
REVISIONS
NO. DATE DESCRIPTION