Level 7a69'-5 1/4"
49-G49-F49-E.1
Level 7_781-5.2569' - 5 1/4"
Level 8_793-4.2581' - 4 1/4"
Level 8_BOS78' - 10 1/4"
49-G49-F49-E.1
Level 7_781-5.2569' - 5 1/4"
Level 8_793-4.2581' - 4 1/4"
Level 8_BOS78' - 10 1/4"
2
MH-401
RA
RA
RA
SA
SA
OA
SD
34"x10"
20"x16"
20"x68"
8"x22"
12"x30"
8"x32"
6"ø
10"x20"EA
OA RAD
OAD
SA
Level 7a69'-5 1/4"
49-67149-8.1 102 49-7
Level 7_781-5.2569' - 5 1/4"
Level 8_793-4.2581' - 4 1/4"
Level 8_BOS78' - 10 1/4"
49-67149-8.1 102 49-7
Level 7_781-5.2569' - 5 1/4"
Level 8_793-4.2581' - 4 1/4"
Level 8_BOS78' - 10 1/4"
1
MH-401
OA
RA
RA
RA
EA
68"x20"
10"x34"
12"x40"
16"x20"
10"x20"
56"x20"
16"x50"RA
6"x10"EA
RA
EF-37
FD-5
FD-9
RAD
OAD
FD-7
SD
49-6
49-6
49-G 49-G
49-F 49-F
49-E.1 49-E.1
71
71
49-8.1
49-8.1
8686
102
102 49-7
49-7 49-6
49-6
49-G 49-G
49-F 49-F
49-E.1 49-E.1
71
71
49-8.1
49-8.1
8686
102
102 49-7
49-7
1
MH-401
2
MH-401
16"x7" 22"x8"
30"x12"6"ø
28"x10"
32"x8"
6"x8"
34"x10"
16"x7"
50"x16" 40"x12"
20"x16"
20"x10"
20"x8"
SD-1200 CFM
CAV-65
RG-3200 CFM
SA
SA
SA
OA
RA
RA
RA
EA
EA
EAEA
10"x6"
FD-5
FD-9
RA
EA
SA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
10/05/18RESPONSIBLE CHARGE
10/05/18COVERING HVAC DESIGN
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/5
/2018 5
:57:5
1 P
M
MH-401
MECHANICAL ROOM SECTIONS
10/05/18 PP KG
1/2" = 1'-0"MH-401
1 C7040 - MECHANICAL ROOM - SOUTH
1/2" = 1'-0"MH-401
2 C7040 - MECHANICAL ROOM - WEST 1/2" = 1'-0"MH-401
3 7TH FLOOR - NEW WORK - MECHANICAL ROOM
Revisions: Date:
W2
W1
W
"D"
45°MAX.
W
1/2" 1/2" 1 1/2"
SE
E N
OTE
4
SEE NOTE 3
SEE NOTE 2
SEE NOTE 1
WITH 3-WAY CONTROL VALVE11
NTS
RADIANT PANEL COIL PIPING DETAIL
COIL
TEST PLUG (TYP.)
REDUCER, IF REQUIRED
WA
TER
RE
TUR
N
MANUAL AIR VENT
UNION CONNECTIONS(TYP.)
WA
TER
SU
PP
LY
BALANCING VALVE
DRAIN WITH HOSECONNECTION
MV NO C
NC
AUTOMATIC 3-WAYVALVE
CONNECT RUNOUT PIPING TOCOIL OFF TOP OF MAIN
WITH 2-WAY CONTROL VALVE7
NTS
AIR TERMINAL UNIT REHEAT COIL PIPING DETAIL
COIL
TEST PLUG (TYP.)
REDUCER, IF REQUIRED
WATER RETURN
MANUAL AIR VENT
UNION CONNECTIONS (TYP.)
WATER SUPPLY
SHUT OFF VALVE
DRAIN WITH HOSECONNECTION
MV
MODULATION CONTROL VALVE
4NTS
DUCTWORK SQUARE VANE ELBOWS
NOTE:
1.
2.
3.
4.
ALL VANE ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS DETAILED BY SMACNA.
WHEN W1 DOES NOT EQUAL W2, VANE SHALL BE SINGLE THICKNESS VANE TYPE REGARDLESS OF W DIMENSION.
ALL SINGLE THICKNESS VANES SHALL HAVE A 2" [50mm] RADIUS, 1 1/2" [40mm] MAXIMUM SPACE BETWEEN VANESAND A 3/4" [20mm] TRAILING EDGE.
WHEN W EQUALS W2 AND W1 IS GREATER THAN 20" [500mm] VANES SHALL BE DOUBLE VANE TYPE.
5NTS
SUPPLY DUCTWORK TAKE-OFFS
AIR SPLIT DUCT TAKE-OFF PLAN VIEW
BRANCH DUCT TAKE-OFF PLAN VIEW
SUPPLY REGISTER TAKE-OFF PLAN VIEW
AIR FLOW
AIR FLOW
AIR
FLO
W
SUPPLY REGISTER ORBRANCH DUCT
TURNING VANES
MAIN SUPPLYDUCT
SEE FLOOR PLAN FOR SPLITDIMENSION
PROVIDE VOLUME DAMPER
PROVIDE VOLUMEDAMPER
ADJUSTABLEMETAL ROD ORLINKAGE
TOP REGISTER
MAINSUPPLYDUCT
VOLUME EXTRACTOR; ADJUSTABLE FROM FULLYCLOSED POSITION TO CFM NOTED ON FLOOR PLANS
AIR FLOW AIR FLOW
1/4 W OR 4" [100mm] MIN.
AIR FLOW
MAIN SUPPLY DUCT
AIR
FLO
W
6NTS
SUPPLY DUCT TAKEOFF - AIR TERMINAL UNIT
RIGID DUCT TO AIR TERMINAL UNIT.
ROUND SHEET METAL DUCT.
MAIN SUPPLY
PLAN VIEW
9NTS
EXHAUST OR RETURN BRANCH DUCTWORK
MAIN EXHAUST OR RETURN
PLAN VIEW
AIR FLOW
AIR FLOW
PROVIDE VOLUME DAMPERAT EACH BRANCH DUCT
1/4W OR 4" [100mm] MIN.
BRANCH DUCT
VD
8NTS
VOLUME DAMPER DETAIL
NOTE:
1.
2.
DELETE INSULATION STAND-OFF ON DUCTWORK WITHOUT EXTERIOR INSULATION.
DETAIL SHOWS SINGLE BLADE DAMPER. DAMPER INSTALLATION SHALL BE SIMILAR FOR MULTI-BLADE DAMPERS &
ROUND DAMPERS.
INSULATION SEESPECIFICATION
DAMPER BLADE
1/8" [6mm]CLEARANCE ALLAROUND
OUTSIDE END BEARING
INSIDE END BEARING
HANDLE WITHLOCKING QUADRANT
INSULATIONSTAND-OFF
1/2" [15mm] ROUND ROD PIN
DUCT
STIFFEN BLADE ASREQUIRED
SIDE ELEVATION SECTION
SECTION "A-A"
"B" "B"
1ACCESS PANEL AND DOOR DETAILNTS
NOTES:
1. LATCHES SHALL BE OF THE WEDGE TYPE TO CLOSE DOORS TIGHTLY.2. HINGES ON THE ACCESS DOORS SHALL HAVE NON-CORROSIVE PINS.3. SEE SMACNA 2005, FIGURE 9-15
ACCESS PANEL
ACCESS DOOR
CASING
GASKETHANDLE INSIDE
FLEXIBLEWASHER
FACTORYFABRICATEDLATCH
SECTION "B-B"
INSULATION
DUCT
GASKET
INSULATION
INSULATION
"A"
"A"
3NTS
FLEXIBLE DUCT CONNECTIONS
ROUND FLEXIBLE CONNECTION
RECTANGULAR FLEXIBLE CONNECTION
FLANGED CONNECTION ONFAN SIDE
WASHER 1-1/2" [40mm] MIN. TO 3" [75mm] MAX. INSTALLED. 6"[150mm] NOMINAL WITH MATERIAL TAUT
FLEXIBLEMATERIAL ASSPECIFIED
1"x1/8" [25x3mm] DRAW BAND
1"x1/8" [25x3mm] BAND IRON
BOLT ON 4" [100mm] CENTERS
5/16" [8mm] FLANGE
DUCT
SHEET METAL SCREWS ON 12"[300mm] CENTERS
RIVET ON 4" [100mm]CENTERS
SHEET METAL ASSPECIFIED FORDUCTWORK.
1"x1/8" [25x3mm] BAND IRON
BOLT ON 4" [100mm] CENTERS
1" [25mm] FLANGE & HEMALTERNATEPOSITION OFBOLT 1 1/2" [40mm] POCKET
SLIP
DUCT
SHEET METAL ASSPECIFIED FORDUCTWORK.
[15mm] [15mm] [40mm]
1 1/2" [40mm] MIN. TO 3" [75mm] MAX. INSTALLED. 6"[150mm] NOMINAL WITH MATERIAL TAUTFLANGED
CONNECTION ONFAN SIDE
WASHER
FLEXIBLE MATERIAL ASSPECIFIED
2NTS
DUCT CONNECTIONS - AIR TERMINAL UNITS
NOTE:
1.
2.
3.
4.
5.
6.
RIGID STRAIGHT TERMINAL UNIT INLET LENGTH SHALL BE A
MINIMUM OF 3 TIMES THE DIAMETER OF INLET
A FLEXIBLE AIR DUCT CONNECTOR IS NOT MANDATORY FOR INLET TO THIS BOX, BUT ALLOWED TOACCOMMODATE MINOR OFFSETS. MAXIMUM LENGTH 3'-0" [900mm].
A BRANCH DUCT SERVING AN INDIVIDUAL BOX MAY BE THE SAME SIZE AS THE BOX INLET,PROVIDED THE EQUIVALENT LENGTH OF THE BRANCH DUCT, AS SHOWN, DOES NOT EXCEED 10
FEET (3 METERS). FOR LONGER LENGTHS, INCREASE THE DUCT SIZE AND PROVIDE A DUCTTRANSITION TO MAINTAIN THE DUCT STATIC PRESSURE DROP AT OR BELOW 0.2"/100' [1.64Pa/m].
FLEXIBLE AIR DUCT CONNECTORS, WHEN USED FROM TERMINAL UNIT SUPPLY AIR DUCT TODIFFUSER, SHALL NOT EXCEED 5'-0" [1500mm]. USE RIGID ELBOWS FOR CHANGE OF DIRECTIONGREATER THAN 45°.
COMPONENT ARRANGEMENT MAY VARY BY MANUFACTURER. PROVIDEINSULATION W/VAPOR BARRIER FOR CONNECTING DUCT SECTIONS.
USE OF THE FLEXIBLE AIR DUCT CONNECTORS ARE NOT PERMITTED FOR THE DEDICATED AHUSERVING THE SURGICAL SUITE.
AIR TERMINAL UNIT (CVOR VAV)
REHEAT COIL
SOUND ATTENUATOR SEEEQUIPMENTSCHEDULE
FLEXIBLE AIR DUCTCONNECTOR. SEE DETAIL
DIFFUSER (TYP.)
SEE SPECIFICATIONS FOR CLAMPS ANDSEALANT (TYP.)
SEE NOTE 5
PIPING CONNECTIONS10
NTS
HYDRONIC RADIANT CEILING PANELS -
RADIANT CEILING PANEL
HWS
HWR
RUNOUT & INTERCONNECTING PIPING. PROVIDEDIELECTRIC FITTINGS AS REQUIRED. CIRCUIT TOCOMPLY WITH SPECIFIED CAPACITY & PRESSUREDROP. (TYP.)
NOTE:
1. MINIMUM FLOW SHALL BE NO LESS THAN0.5 GPM [1.9 LPM]
NOTE:
1.
2.
FOR RUNOUT PIPING SIZE REFER TO AIR TERMINAL UNITMINIMUM RUNOUT PIPING SIZE SHALL BE 3_
4" DIAMETER
PROVIDE AUTOMATIC 3-WAY VALVE BASED ON ATU SCHEDULE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
10/05/18RESPONSIBLE CHARGE
10/05/18COVERING HVAC DESIGN
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/5
/2018 5
:57:5
1 P
M
MH-501
HVAC DETAILS I
10/05/18 PP KGRevisions: Date:
25m
m1"
MA
X
PROVIDE INSULATION SHIELD& INSERT FOR ALL PIPING(200mm [8"] MIN.)
BAND
43mm [1-5/8"] 12 GAUGECHANNEL OR 50x50x6.4mm[2"X2"X1/4"] ANGLE
15mm [1/2"] DIA.HANGER RODS WITH900mm [36"] MAX.SPACING ON EACHCHANNEL
WELD
SADDLE
INSULATION SHIELDAT HANGER
PROVIDE HIGH COMPRESSIVESTRENGTH INSULATION (9 PSF MIN.DENSITY) UNDER INSULATION SHIELD
INSULATION (VAPORBARRIER TYPE ISREQUIRED FOR LOWTEMPERATURE PIPE)
HANGER ROD
NOTE:SEE SPECIFER FOR DETAILED HANGER REQUIREMENTS
1"
5NTS
SIDE VIEW TRAPEZE HANGER FOR UP TO453KG [1000 LB.] UNIFORM LOAD
ADJUSTABLE CLEVIS HANGER TYPE 1 -SEE SPECIFICATIONS
ADJUSTABLE CLEVIS HANGER TYPE 43 -SEE SPECIFICATIONS
MAXIMUM PIPE/TUBING SUPPORT SPACING
NOTE: FOR TRAPEZE HANGER TAKE SPACING OF SMALLEST SIZE ON TRAPEZE.
NOM. SIZE
PIPE
TUBING
PIPE HANGERS
mm[IN]
mm[FT]
mm[FT]
THRU 20
[THRU 3/4]
2100[7]
1500[5]
25[1]
2100[7]
1800[6]
32
[11/4]
2100[7]
2100[7]
40
[11/2]
2700[9]
2400[8]
50[2]
3000[10]
2400[8]
65
[21/2]
3400[11]
2700[9]
75[3]
3700[12]
3000[10]
100[4]
4100[14]
3700[12]
125[5]
4900[16]
4000[13]
150[6]
5200[17]
4100[14]
200[8]
5800[19]
4900[16]
250[10]
6700[22]
--
300[12]
7000[23]
--
350[14]
7600[25]
--
400[16]
8200[27]
--
450[18]
8500[28]
--
500[20]
9100[30]
--
600[24]
9600[32]
--
6NTS
NOTES:1. SEE SPECIFICATION SECTION "PUMPS" FOR Y STRAINER OPTION
FIRST 3 HANGERS FOR EACH PIPE AND BRANCHSHALL BE SPRING & NEOPRENE TYPE. TYPE "H" FOR4" [100mm] DIA. PIPE & SMALLER. TYPE "H-P" FOR 5"[125mm] DIA. PIPE & LARGER.
RIGID PIPEHANGER
INSTALL HANGER AS CLOSE TO PIPEELBOW AS POSSIBLE (TYPICAL)
1/2" [15mm]
FLEXIBLE CONNECTOR (TYPICAL)
PUMP
FLOOR
VIBRATION ISOLATOR(TYPICAL)
1" [25mm] MIN.DIA. PIPE STAND
CONCRETE INERTIABASE
DRAIN
SUCTION DIFFUSERWITH BUILT IN STRAINER.OPTIONAL: LONG RADIUSELBOW AND INLETSTRAINER WITH 3XDIAMSTRAIGHT INLET TO PUMP
1/2" [15mm]
PRESSURE GAUGE
RIGID PIPEHANGER
SINGLE SUCTION FLOOR-MOUNTED PUMPS -CONNECTIONS WITH FLEXIBLE CONNECTORS
OPTIONAL STRAINER
BUTTERFLY OR BALLSHUT OFF VALVE, TYP.
CHECK VALVE
1
2NTS
FIRE DAMPER INSTALLATIONSECTION THRU
NOTE:
1.
2.
3.
4.
5.
6.
A VERTICAL DAMPER IS SHOWN. HORIZONTAL DAMPER INSTALLATION, 1S SIMILAR. FOLLOW DAMPER MANUFACTURER'SINSTRUCTIONS, INCLUDING FASTENER OPTIONS AND GAGES FOR SLEEVE AND PERIMETER ANGLES. FIRE DAMPERS MUSTBE INSTALLED IN THE PARTITION OR FLOOR AND NOT OUTSIDE THE PENETRATION.
GALVANIZED SLEEVE: GAGE NOT LESS THAN CONNECTING DUCT. FASTEN SLEEVE TO DAMPER FRAME AND TOPERIMETER ANGLES.
PERIMETER ANGELS: GALVANIZED STEEL, NOT LESS THAN 1 1/2"x1 1/2" [40x40mm], 14 GAGE, TO PROVIDE 1" [25mm]MINIMUM OVERLAP OF OPENING ON ALL 4 SIDES.
BREAKAWAY DUCT CONNECTION: CONTRACTOR'S OPTION OF TYPES SHOWN IN SMACNA.ACCESS PANELS: SIZE AND LOCATION TO PERMIT SERVICING THE FUSIBLE LINK OR LINKS.
PROVIDE 1/4" TO 1/2" [6 TO 15mm] CLEARANCE ON HEIGHT AND WIDTH. FILL OPEN SPACE WITH ROCK WOOL FIRESTOPFIBER.
ALL DUCT WORK RISERS WHICH ARE RUN EXPOSED, SUCH AS THRU ATTIC FLOORS AND MECHANICAL ROOM FLOORS,SHALL BE PROVIDED WITH 3" [75mm] HIGH CONCRETE CURB AROUND OPENING FOR DUCT.
SLEEVE, NOTE 2
DUCTCONNECTIONNOTE 4
DAMPER, NOTE 1
DAMPER COLLAR EXTENSIONINTEGRAL PART OF SLEEVE
SLEEVE, NOTE 2
NOTE 6FIRE BARRIER PARTITION ORCHASE
TYPICAL DUCTINSULATION
PERIMETER ANGLE, NOTE 3 (NOTEFASTENED TO PARTITION)
ACCESSPANEL NOTE 5
[25m
m]
4NTS
SMOKE DAMPER CONTROLS1
NTS
TYP ROOM WITH EXTERIOR EXPOSURE
3/4" HWS
3/4" HWR
VARIABLE AIR VOLUMETERMINAL WITH HOT
WATER REHEAT
HD
3/4" HWS
3/4" HWR
RADIANT CEILINGHEATING PANEL
WINDOW
WALL
WALL
4'-0"
2'-0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
10/05/18RESPONSIBLE CHARGE
10/05/18COVERING HVAC DESIGN
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/5
/2018 5
:57:5
2 P
M
MH-502
HVAC DETAILS II
10/05/18 PP KGRevisions: Date:
VARIABLE AIR VOLUMEAIR TERMINAL UNIT & RADIANT PANEL
HOT HEATING WATERRISER DIAGRAM - EAST AND WEST CHASES
HEATING HOT WATERHEAT EXHANGER DIAGRAM
9TH FLOOR
8TH FLOOR
7TH FLOOR
6TH FLOOR
5TH FLOOR
4TH FLOOR
3RD FLOOR
2ND FLOOR
1ST FLOOR
BASEMENT
PENTHOUSE
EXISTING 4" HWS
EXISTING 4" HWR
EXIST. HWS
EXIST. HWR
NEW 4" HWS
NEW 4" HWR
EXIST. HWS
EXIST. HWR
EXIST. HWS
EXIST. HWR
WEST CHASE EAST CHASE
EXIST. HWS
EXIST. HWR
EXIST. HWS
EXIST. HWR
EX
IST
. H
WS
EX
IST
. H
WR
NE
W 4
" H
WR
NE
W 4
" H
WS
EX
IST
. H
WR
EX
IST
. H
WS
TO HEXC5
FROM HEXC5
HEXC5
PUMPED COND ANDPREHEAT SYSTEM
L. P. STEAM
TO HWSPUMPS
HWR
FILTER
A.S.
CHEMICALBY-PASSFEEDER
FROMHWSPUMPS
TO HWSUSERS
EXIST. HWS
EXIST. HWR
EXIST. HWS
EXIST. HWR
EXIST. HWS
EXIST. HWR
EXIST. HWS
EXIST. HWR
EXIST. HWS
EXIST. HWR
EXIST. HWS
EXIST. HWR
EXIST. HWS
EXIST. HWR
EXIST. HWS
EXIST. HWR
EXIST. HWS
EXIST. HWR
EXIST. HWS
EXIST. HWR
EXIST. HWS
EXIST. HWR
EXIST. HWS
EXIST. HWR
NEW HWS
NEW HWR
NEW HWS
NEW HWR
EXIST. HWS
EXIST. HWR
EXIST. HWS
EXIST. HWR
C SPACE TEMP
SENSOR
T
T
SUPPLY
HW
HH
WH
R
C
HW
HS
HW
HR
PANEL
TERMINAL
TO HEATING COIL
SEQUENCES OF OPERATIONA. GENERAL:
1. HVAC SYSTEMS SHALL BE CONTROLLED WITH DIRECT DIGITAL CONTROL (DDC) ACCORDING TO SEQUENCES SHOWN.
2. ADDITIONAL POINTS OR SOFTWARE PROGRAMMING NOT LISTED BUT WHICH ARE REQUIRED TO MEET FOLLOWING SEQUENCES OF
OPERATION SHALL BE PROVIDED.
3. HOUSE CONTROLLERS, RELAYS, TRANSDUCERS, AND OTHER COMPONENTS REQUIRED FOR STAND-ALONE CONTROL SHALL BE
PROVIDED INSIDE A NEMA 1 ENCLOSURE WITH LOCKABLE DOOR.
4. ACTUATORS ON MOTORIZED VALVES AND DAMPERS ON AIR HANDLING UNITS, CHILLED WATER, AND HOT WATER SYSTEMS TO BE DDC.
SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
5. ALL FIRE/SMOKE DAMPERS SHALL BE MONITORED BY BAS FOR TROUBLE CONDITIONS.
6. ALL AH AND SYSTEM SMOKE DAMPERS SHALL BE HARD-WIRE INTERLOCKED SUCH THAT THEY CLOSE FULLY WHEN AH FANS STOP.
7. A HAND-OFF-AUTO SWITCH FEATURE AT THE AH SUPPLY FAN AND AT EACH REMOTE EXHAUST FAN EF-32 AND EF-37 PERMITS MANUAL
OR AUTOMATIC OPERATION OF EACH FAN.
A) IN AUTO MODE, THE FAN IS ENABLED AND DISABLED BY THE DDC SYSTEM.
B) IN HAND MODE, THE FAN IS ENABLED FOR OPERATION REGARDLESS OF THE COMMAND FROM THE DDC SYSTEM. THE DDC SYSTEM
STILL MAY ATTEMPT TO ISSUE COMMANDS TO CONTROL THE FAN AND WILL CONTROL OTHER CONTROL LOOPS, BUT HAND MODE
TAKES THE FAN OUT OF AUTO MODE AND MANUALLY OVERRIDES THE FAN ON.
C) IN OFF MODE, THE FAN IS DISABLED REGARDLESS OF THE COMMAND FROM THE DDC SYSTEM. OFF MODE TAKES THE FAN OUT OF
AUTO MODE AND MANUALLY OVERRIDES THE FAN OFF.
D) SAFETIES (FREEZESTAT, HIGH AND LOW STATIC PRESSURE SWITCHES) OVERRIDE ALL HAND-OFF-AUTO COMMANDS AND FORCE THE
FANS OFF UNTIL MANUALLY RESET.
8. THE AH SUPPLY FAN AND BOTH REMOTE EXHAUST FANS EACH HAVE A CURRENT SWITCH FOR STATUS. IF THE SUPPLY FAN STATUS
OR EITHER REMOTE EXHAUST FAN INDICATES OFF, A HARDWIRED INTERLOCK CAUSES THE OTHER FANS TO GO OFF, OUTSIDE AIR
DAMPER TO CLOSE, RETURN AIR DAMPER TO OPEN, SMOKE DAMPERS AT AH AND EACH FAN TO CLOSE, AND EACH EXHAUST FAN
SHUTOFF DAMPER TO CLOSE.
B. SETPOINTS:
1. ALL SETPOINTS GIVEN IN THE SEQUENCE OF OPERATIONS OR IN THE DRAWINGS ARE FOR SYSTEM STARTUP AND ARE PRELIMINARY
AND SHALL BE ADJUSTABLE.
2. OPTIMUM OPERATING SETPOINTS MUST BE DETERMINED DURING ACTUAL OCCUPANCY AND WILL BE AFFECTED BY MANY FACTORS.
THESE MAY INCLUDE:
A) WEATHER CONDITIONS.
B) BUILDING OCCUPANCY.
C) BUILDING UTILIZATION PATTERNS.
D) VARIATIONS IN BUILDING CONSTRUCTION.
E) VARIATIONS IN OPERATING CHARACTERISTICS OF ACTUAL INSTALLED BUILDING EQUIPMENT.
IT IS THE RESPONSIBILITY OF THE BUILDING OPERATORS TO DETERMINE THOSE SETTINGS AND OPERATING METHODS WHICH
PROVIDE THE BEST BALANCE OF OPERATING EFFICIENCY AND OCCUPANT COMFORT. THIS IS AN ONGOING PROCESS. OPTIMUM
SETTINGS CHANGE AS OPERATING CONDITIONS CHANGE.
C. AIR HANDLING UNIT AH-70 AND REMOTE EXHAUST FANS EF-32 AND EF-37
1. GENERAL:
A) AH-70 IS A MINIMUM OUTSIDE AIR, VARIABLE AIR VOLUME WITH VARIABLE AIR VOLUME TERMINAL UNITS WITH REHEAT AND
PERIMETER RADIANT HEATING CEILING PANELS. THE AH HAS MIXING DAMPERS (OUTSIDE AIR DAMPER AND RETURN AIR DAMPER),
OUTSIDE AIRFLOW MEASURING STATION, SINGLE POINT TYPE RETURN TEMPERATURE SENSOR, RETURN HUMIDITY SENSOR,
RETURN SMOKE DAMPER WITH END SWITCH, RETURN SMOKE DETECTOR, LOW STATIC PRESSURE SWITCH, PREFILTER WITH
DIFFERENTIAL PRESSURE GAUGE, LOW LIMIT THERMOSTAT (FREEZESTAT), CHILLED WATER COOLING COIL WITH THREE-WAY VALVE,
AVERAGING TYPE COOLING COIL DISCHARGE AIR TEMPERATURE SENSOR (TS-1), SUPPLY FAN WITH VFD, AVERAGING TYPE
DISCHARGE AIR TEMPERATURE SENSOR (TS-2), HIGH STATIC PRESSURE SWITCH, SUPPLY SMOKE DETECTOR, SUPPLY SMOKE
DAMPER WITH END SWITCH, AND A DIFFERENTIAL STATIC PRESSURE SENSOR. TWO REMOTE EXHAUST FANS (EF-32 & EF-37) ARE
INTERLOCKED WITH AH-70. EACH REMOTE EXHAUST FAN HAS AN EXHAUST SMOKE DETECTOR, A MOTORIZED EXHAUST SHUTOFF
DAMPER, A SMOKE DAMPER WITH END SWITCH, AN EXHAUST FAN AIRFLOW MEASURING STATION, A LOW STATIC PRESSURE
SWITCH, AND A VFD.
B) AH SUPPLY AND REMOTE EXHAUST FANS SHALL EACH BE INTERLOCKED THROUGH A DAMPER END SWITCH, SO EACH CANNOT
START UNTIL ITS RESPECTIVE OUTSIDE OR EXHAUST AND SMOKE DAMPER ARE FULLY OPEN.
C) THE UNIT'S OCCUPIED, UNOCCUPIED, PRE-OCCUPANCY TIME PERIOD IS DETERMINED BY A TIME SCHEDULE AND PROGRAMMING.
2. UNOCCUPIED MODE:
A) DURING UNOCCUPIED MODE, THE AH IS OFF UNLESS THERE IS A CALL FOR HEATING OR COOLING OR DEHUMIDIFICATION TO
MAINTAIN UNOCCUPIED SPACE SETPOINTS OR FOR UNOCCUPIED MORNING WARM-UP OR COOL-DOWN CYCLE. WHEN THE AH IS
OFF, SUPPLY FAN AND REMOTE EXHAUST FANS ARE OFF, AND ALL DAMPERS AND VALVES GO TO NORMAL POSITIONS AS SHOWN ON
THE AH AND REMOTE EXHAUST FAN CONTROL SCHEMATICS.
B) UNOCCUPIED SPACE SETPOINTS ARE AS FOLLOWS:
UNOCCUPIED HEATING SETPOINT 60°F (ADJUSTABLE).
UNOCCUPIED COOLING SETPOINT 82°F (ADJUSTABLE).
WHENEVER AH IS STARTED TO MAINTAIN UNOCCUPIED SPACE SETPOINTS, IT BEHAVES AS IF IN OCCUPIED MODE EXCEPT IN FULL
RETURN MODE WITH OUTDOOR AIR DAMPER CLOSED AND REMOTE EXHAUST FANS REMAIN OFF. WHEN UNOCCUPIED SPACE
SETPOINTS ARE SATISFIED, THE AH WILL STOP.
C) UNOCCUPIED HEATING SETBACK MODE IS MAINTAINED AS FOLLOWS: IF ANY SPACE SENSOR READS BELOW THE UNOCCUPIED
HEATING SETPOINT, THE AH WILL BE STARTED AND RUN UNTIL ALL UNOCCUPIED HEATING SPACE SETPOINTS ARE SATISFIED. THE
AH MIXING DAMPERS WILL MODULATE TO FULL RETURN MODE TO MAINTAIN THE HIGHEST SUPPLY AIR TEMPERATURE SETPOINT
POSSIBLE. TERMINAL UNITS IN UNSATISFIED SPACES WILL BEHAVE AS IF IN OCCUPIED MODE UNTIL SETPOINT IS SATISFIED.
D) UNOCCUPIED COOLING SETUP MODE IS MAINTAINED AS FOLLOWS: IF ANY SPACE SENSOR READS ABOVE THE UNOCCUPIED
COOLING SETPOINT, THE AH WILL BE STARTED AND RUN UNTIL ALL UNOCCUPIED COOLING SPACE SETPOINTS ARE SATISFIED. THE
AH COOLING COIL VALVE WILL MODULATE OPEN TO MAINTAIN THE LOWEST RESET AH SUPPLY AIR TEMPERATURE SETPOINT. SEE
AH SUPPLY AIR TEMPERATURE RESET SCHEDULE. TERMINAL UNITS IN UNSATISFIED SPACES WILL BEHAVE AS IF IN OCCUPIED
MODE UNTIL SETPOINT IS SATISFIED.
3. PRE-OCCUPANCY MODE:
A) PRE-OCCUPANCY MODE IS INITIALLY SCHEDULED, AND THE SCHEDULED START TIME IS OPTIMIZED BASED ON INSIDE AND OUTSIDE
AIR TEMPERATURE AND SYSTEM HISTORY OF PERFORMANCE. THE DDC CONTROLLER CALCULATES THE OPTIMUM
PRE-OCCUPANCY MODE HEATING/COOLING TIME NECESSARY TO BRING BUILDING TO OCCUPIED TEMPERATURE IN EITHER
WARM-UP OR COOL-DOWN CYCLES.
B) UPON INITIATION OF A START IN PRE-OCCUPANCY MODE (WARM-UP OR COOL-DOWN CYCLE), THE FOLLOWING EVENTS OCCUR:
1) OPEN RETURN AIR DAMPER AND RETURN AND SUPPLY AIR SMOKE DAMPERS.
2) OUTSIDE AIR DAMPER SHALL REMAIN CLOSED.
3) REMOTE EXHAUST FANS SHALL REMAIN OFF.
4) WHEN AH RETURN, AND SUPPLY SMOKE DAMPERS ARE FULLY OPEN, END SWITCHES SHALL ALLOW AH SUPPLY FAN TO
START.
C) PRE-OCCUPANCY WARM-UP CYCLE: DURING PRE-OCCUPANCY MODE, THE DDC SYSTEM OPERATES THE UNIT IN ITS WARM-UP
CYCLE IF THE AVERAGE SPACE TEMPERATURE OF THE VAV BOX ZONES SERVED BY THE UNIT IS BELOW 70°F (ADJUSTABLE). THE
FOLLOWING EVENTS OCCUR DURING PRE-OCCUPANCY WARM-UP CYCLE:
1) OUTSIDE AIR DAMPER IS CLOSED.
2) RETURN AIR DAMPER IS OPEN.
3) REMOTE EXHAUST FANS ARE OFF.
4) AH COOLING COIL VALVE IS CLOSED TO COIL.
5) THE AH MIXING DAMPERS WILL MODULATE TO FULL RETURN MODE TO MAINTAIN THE HIGHEST RESET AH SUPPLY AIR
TEMPERATURE SETPOINT POSSIBLE. SUPPLY FAN WILL MODULATE TO MAINTAIN SUPPLY DUCT STATIC PRESSURE AT SETPOINT.
6) TERMINAL UNITS WILL BEHAVE AS IF IN OCCUPIED MODE UNTIL EACH OCCUPIED SPACE SETPOINT IS SATISFIED.
7) WARM-UP MODE IS TERMINATED WHEN THE UNIT IS INDEXED TO ITS OCCUPIED MODE TIME PERIOD, OR WHEN ALL SPACES
REACH THEIR OCCUPIED HEATING SPACE TEMPERATURE SETPOINTS BEFORE OCCUPIED MODE TIME PERIOD BEGINS. SEE
OCCUPIED MODE SEQUENCE FOR OCCUPIED SPACE TEMPERATURE SETPOINTS.
D) PRE-OCCUPANCY COOL-DOWN CYCLE: DURING PRE-OCCUPANCY MODE, THE DDC SYSTEM OPERATES THE UNIT IN ITS COOL-DOWN
CYCLE IF THE AVERAGE SPACE TEMPERATURE OF THE VAV BOX ZONES SERVED BY THE UNIT IS ABOVE 75°F (ADJUSTABLE). THE
FOLLOWING EVENTS OCCUR DURING PRE-OCCUPANCY COOL-DOWN CYCLE:
1) OUTSIDE AIR DAMPER IS CLOSED.
2) RETURN AIR DAMPER IS OPEN.
3) REMOTE EXHAUST FANS ARE OFF.
4) THE AH MIXING DAMPERS WILL MODULATE TO FULL RETURN MODE AND THE AH COOLING COIL VALVE WILL MODULATE OPEN
TO MAINTAIN THE LOWEST RESET AH SUPPLY AIR TEMPERATURE SETPOINT. SEE AH SUPPLY AIR TEMPERATURE RESET
SCHEDULE.
5) SUPPLY FAN WILL MODULATE TO MAINTAIN SUPPLY DUCT STATIC PRESSURE AT SETPOINT.
6) TERMINAL UNITS WILL BEHAVE AS IF IN OCCUPIED MODE UNTIL EACH OCCUPIED SPACE SETPOINT IS SATISFIED.
7) COOL-DOWN MODE IS TERMINATED WHEN THE UNIT IS INDEXED TO ITS OCCUPIED MODE TIME PERIOD, OR WHEN ALL SPACES
REACH THEIR OCCUPIED COOLING SPACE TEMPERATURE SETPOINTS BEFORE OCCUPIED MODE TIME PERIOD BEGINS. SEE
OCCUPIED MODE SEQUENCE FOR OCCUPIED SPACE TEMPERATURE SETPOINTS.
4. OCCUPIED MODE:
A) OCCUPIED SCHEDULE: OCCUPIED MODE STARTS BASED ON AN ADJUSTABLE SCHEDULE.
B) UPON A TRANSITION FROM PRE-OCCUPANCY MODE TO OCCUPIED MODE, THE FOLLOWING EVENTS OCCUR:
1) OPEN BOTH REMOTE EXHAUST FAN SHUTOFF AND SMOKE DAMPERS.
2) OUTSIDE AIR DAMPER SHALL BE OPENED TO ITS MINIMUM OUTDOOR AIR POSITION.
3) WHEN OUTDOOR AND DAMPER AND BOTH REMOTE EXHAUST FAN SMOKE DAMPERS ARE FULLY OPEN, END SWITCHES SHALL
ALLOW BOTH EXHAUST FANS TO START.
4) SUPPLY AND EXHAUST FANS RUN CONTINUOUSLY DURING OCCUPIED MODE, AND IF THEY ARE ALL RUNNING, THE DDC
SYSTEM INDEXES THE UNIT TO OCCUPIED MODE.
5) OCCUPIED SPACE SETPOINTS ARE AS FOLLOWS:
OCCUPIED HEATING SETPOINT 70°F (ADJUSTABLE).
OCCUPIED COOLING SETPOINT 75°F (ADJUSTABLE).
6) THE FOLLOWING AH CONTROL LOOPS WILL OPERATE TO MAINTAIN SETPOINTS DURING OCCUPIED MODE:
A. COOLING DISCHARGE AIR TEMPERATURE CONTROL LOOP.
B. MIXED AIR TEMPERATURE CONTROL LOOP.
C. MINIMUM OUTDOOR AIR CONTROL LOOP.
D. SUPPLY AIR DUCT STATIC CONTROL LOOP.
C) COOLING DISCHARGE AIR TEMPERATURE CONTROL LOOP:
1) MIXED AIR DAMPERS (OUTDOOR AND RETURN AIR DAMPERS) AND COOLING COIL VALVE SHALL MODULATE IN SEQUENCE TO
MAINTAIN THE RESET COOLING DISCHARGE AIR TEMPERATURE SETPOINT AT DISCHARGE AIR TEMPERATURE SENSOR TS-2.
2) THE UNIT'S DISCHARGE AIR TEMPERATURE SETPOINT IS RESET BASED ON VAV BOX WITH THE HIGHEST COOLING DEMAND.
DISCHARGE AIR TEMPERATURE RESET SCHEDULE:
A. DISCHARGE AIR TEMPERATURE SHALL BE RESET USING TRIM AND RESPOND LOGIC WITHIN THE RANGE 52°F (ADJUSTABLE) TO 62°F
(ADJUSTABLE). WHEN THE FAN IS OFF, FREEZE T-MAX AT THE MAXIMUM VALUE (62°F). WHILE FAN IS PROVEN ON, EVERY 2 MINUTES
(ADJUSTABLE), INCREASE THE SETPOINT BY 0.2°F (ADJUSTABLE) IF THERE ARE TWO (ADJUSTABLE) OR FEWER ZONE COOLING
REQUESTS. [ADJUST THE “TWO” OR FEWER ZONE COOLING REQUESTS VALUE TO LIMIT DOMINANCE OF ROGUE ZONES.] IF THERE ARE
MORE THAN TWO (ADJUSTABLE) COOLING REQUESTS, DECREASE THE SETPOINT BY 0.3°F (ADJUSTABLE). A COOLING REQUEST IS
GENERATED WHEN THE COOLING LOOP OF ANY ZONE SERVED BY THE SYSTEM IS >99% (ADJUSTABLE).
D) MIXED AIR TEMPERATURE CONTROL LOOP:
1) MIXED AIR DAMPERS (OUTDOOR AND RETURN AIR DAMPERS) SHALL MODULATE TO MAINTAIN THE MIXED AIR TEMPERATURE
SETPOINT OF 68°F (ADJUSTABLE).
E) MINIMUM OUTDOOR AIR CONTROL LOOP:
1) MIXED AIR DAMPERS (OUTDOOR AND RETURN AIR DAMPERS), BOTH EXHAUST FANS, AND SUPPLY FAN SHALL MODULATE IN
SEQUENCE TO MAINTAIN 4,200 CFM (ADJUSTABLE) MINIMUM OUTDOOR AIR SETPOINT MEASURED AT THE MINIMUM OUTDOOR
AIRFLOW MEASURING STATION.
2) EXHAUST FAN EF-32 (SERVES 6TH FLOOR) MODULATES TO MAINTAIN AIRFLOW SETPOINT AT 1,800 CFM (ADJUSTABLE), AND
EF-37 (SERVES 7TH FLOOR) MODULATES TO MAINTAIN AIRFLOW SETPOINT AT 2,200 CFM (ADJUSTABLE).
F) SUPPLY AIR DUCT STATIC CONTROL LOOP:
1) SUPPLY FAN MODULATES TO MAINTAIN A RESET DUCT STATIC PRESSURE SETPOINT WHENEVER THE SUPPLY FAIN RUNS.
DUCT STATIC PRESSURE SENSOR SHALL BE LOCATED APPROXIMATELY 2/3 OF THE WAY DOWNSTREAM OF THE AH. OPTIMUM
LOCATION SHALL BE DETERMINED IN THE FIELD BASED ON FIELD CONDITIONS AND MANUFACTURER'S INSTALLATION
INSTRUCTIONS. FINAL SETPOINTS SHALL BE DETERMINED WITH THE ASSISTANCE OF THE BALANCE CONTRACTOR.
2) SUPPLY AIR DUCT STATIC PRESSURE RESET LOGIC (TRIM & RESPOND):
STATIC PRESSURE SETPOINT SHALL BE RESET USING TRIM AND RESPOND LOGIC WITHIN THE RANGE 0.15 INWG (ADJUSTABLE) TO
2 INWG (ADJUSTABLE) AS SET BY BALANCE CONTRACTOR. WHEN FAN IS OFF, FREEZE SETPOINT AT THE MINIMUM VALUE. WHILE
FAN IS PROVEN ON, EVERY 2 MINUTES (ADJUSTABLE), DECREASE SETPOINT BY 0.04 INWG (ADJUSTABLE) IF THERE ARE TWO
(ADJUSTABLE) OR FEWER PRESSURE REQUESTS. [ADJUST THE “TWO” OR FEWER ZONE COOLING REQUESTS VALUE TO LIMIT
DOMINANCE OF ROGUE ZONES.] IF THERE ARE MORE THAN TWO (ADJUSTABLE) PRESSURE REQUESTS, INCREASE THE SETPOINT
BY 0.04 INWG (ADJUSTABLE). WHERE VAV ZONE DAMPER POSITION IS KNOWN, A PRESSURE REQUEST IS GENERATED WHEN ANY
VAV DAMPER SERVED BY THE SYSTEM IS WIDE OPEN. WHERE VAV ZONE DAMPER POSITION IS UNKNOWN, A PRESSURE
REQUEST IS MADE WHEN THE RATIO OF THE ZONE'S ACTUAL SUPPLY AIRFLOW TO SUPPLY AIRFLOW SETPOINT IS LESS THAN 90%
(ADJUSTABLE).
G) AH SHUTDOWN MODE: UPON AH SUPPLY FAN AND REMOTE EXHAUST FAN SHUTDOWN, ALL AH, BOTH EXHAUST FAN SYSTEM
SMOKE DAMPERS AND EXHAUST FAN SHUTOFF DAMPER SHALL CLOSE FULLY. OUTSIDE AIR DAMPER CLOSES FULLY AND RETURN
AIR DAMPER OPENS FULLY. AH DAMPER OPERATORS SHALL BE ADJUSTED SUCH THAT CLOSING OF SMOKE DAMPERS WILL BE
DELAYED UNTIL FAN ROLLS TO NEAR STOP.
1) SAFETIES:
2) ALL SAFETY/EMERGENCY CONTROLS SHALL BE HARD-WIRE INTERLOCKED SUCH THAT THEY ARE NOT DEPENDENT UPON DDC
SYSTEM SOFTWARE.
3) SMOKE CONTROL:
A) DUCT MOUNTED AIR SMOKE DETECTORS WILL BE FURNISHED AND INSTALLED AS SHOWN. PROVIDE POWER AND ALARM, CONTROL
AND INTERLOCK WIRING.
B) WHENEVER ANY DUCT-MOUNTED SMOKE DETECTOR GOES INTO ALARM, IT SHALL PERFORM THE FOLLOWING:
1. STOP ALL UNIT FANS.
2. CLOSE ALL ASSOCIATED SMOKE DAMPERS.
3. NOTIFY THE FIRE ALARM SYSTEM.
4. THIS CONTROL MUST BE MANUALLY RESET.
5. SMOKE ALARMS AFFECT ONLY AIR SYSTEMS SERVING THE ZONE IN ALARM. AIR SYSTEMS SERVING THE OTHER ZONES
CONTINUE TO OPERATE NORMALLY.
4) FREEZE PROTECTION:
A) IF THE AIR TEMPERATURE SENSED BY THE LOW LIMIT THERMOSTAT (FREEZESTAT) FZ-1 FALLS BELOW 45°F (ADJUSTABLE), AN
ALARM SHALL INDICATE AT THE ECC OPERATOR CONTROL PANEL (OCP).
B) IF THIS TEMPERATURE FALLS BELOW 40°F (ADJUSTABLE), THE SUPPLY FAN AND BOTH EXHAUST FANS SHALL SHUT DOWN AND A
CRITICAL ALARM SHALL INDICATE AT ECC OCP.
5) LOW STATIC PRESSURE AT EXHAUST FANS AND AH SUPPLY FAN
A) IF THE PRESSURE SWITCH LOW (PSL) AT EITHER EXHAUST FAN OR AH SUPPLY FAN SENSES A STATIC PRESSURE CONDITION BELOW
ITS SETPOINT OF -3 INWG (ADJUSTABLE), BOTH REMOTE EXHAUST FANS AND THE AH SUPPLY FAN SHALL BE DISABLED, AND
CONTROLS SHALL GO TO THEIR NORMAL POSITIONS UNTIL SAFETY THAT TRIPPED IS RESET MANUALLY.
B) IF THE PRESSURE SWITCH HIGH (PSH) AT THE DISCHARGE OF THE AH SUPPLY FAN SENSES A STATIC PRESSURE CONDITION ABOVE
ITS SETPOINT OF +3 INWG (ADJUSTABLE), BOTH REMOTE EXHAUST FANS AND THE AH SUPPLY FAN SHALL BE DISABLED, AND
CONTROLS SHALL GO TO THEIR NORMAL POSITIONS UNTIL SAFETY THAT TRIPPED IS RESET MANUALLY.
6) ALARMS: THE DDC GENERATES AN ALARM WHENEVER ANY OF THE FOLLOWING OCCURS:
A) THE SUPPLY FAN IS COMMANDED ON AND FAILS TO RUN.
B) THE SUPPLY FAN IS COMMANDED OFF BUT RUNS.
C) THE SUPPLY FAN SPEED DRIVE FAULT CONTACT IS ON.
D) EITHER EXHAUST FAN IS COMMANDED ON AND FAILS TO RUN.
E) EITHER EXHAUST FAN IS COMMANDED OFF BUT RUNS.
F) EITHER EXHAUST FAN SPEED DRIVE FAULT CONTACT IS ON.
G) THE LOW TEMPERATURE CUTOUT (FREEZESTAT) IS ACTIVATED.
H) ANY PRESSURE SWITCH IS ACTIVATED. PROVIDE UNIQUE ALARM FOR EACH PRESSURE SWITCH WITH UNIQUE TAGS.
I) THE SUPPLY AIR STATIC PRESSURE SENSOR FAILS (PRESSURE MORE THAN 10% ABOVE FINAL HIGH SETPOINT, ADJUSTABLE).
J) MIXED AIR TEMPERATURE SENSOR FAILS (LESS THAN 0°F, ADJUSTABLE OR MORE THAN 120°F, ADJUSTABLE).
K) MIXED AIR TEMPERATURE SENSOR FALLS BELOW 40°F, ADJUSTABLE.
L) DISCHARGE AIR TEMPERATURE SENSOR FAILS (LESS THAN 20°F, ADJUSTABLE OR MORE THAN 120°F, ADJUSTABLE).
M) RETURN AIR TEMPERATURE SENSOR FAILS (LESS THAN 20°F, ADJUSTABLE OR MORE THAN 120°F, ADJUSTABLE).
N) THE OUTSIDE AIRFLOW RATE IS LESS THAN 75% (ADJUSTABLE) OF MINIMUM OUTSIDE AIRFLOW SETPOINT, FOR A TIME PERIOD
GREATER THAN 15 MINUTES (ADJUSTABLE), WHEN OUTSIDE/RETURN AIR DAMPER OPERATION HAS BEEN ENABLED.
D. VARIABLE VOLUME AIR TERMINAL UNITS WITH REHEAT AND RADIANT PANELS:
1. DIRECT DIGITAL AIRFLOW CONTROLLER, DIFFERENTIAL PRESSURE SENSOR, AND ELECTRONIC DAMPER ACTUATOR SHALL BE
FURNISHED UNDER THIS SECTION BUT SHALL BE FACTORY MOUNTED BY THE TERMINAL UNIT MANUFACTURER. REHEAT AND RADIANT
PANEL CONTROL VALVES SHALL BE FURNISHED UNDER THIS SECTION BUT CAN BE FIELD INSTALLED.
2. SPACE COOLING AND HEATING SETPOINTS SHALL HAVE SEPARATE OCCUPIED AND UNOCCUPIED SETTINGS, AND CONTROLLER
SHALL AUTOMATICALLY SHIFT BETWEEN OCCUPIED AND UNOCCUPIED SETTINGS WHEN ASSOCIATED AH IS SHIFTED. SEE
UNOCCUPIED AND OCCUPIED SPACE SETPOINTS SECTIONS OF AH SEQUENCES.
3. IN PATIENT ROOMS, PRIVATE OFFICES, AND SIMILAR SPACES, SETPOINT SHALL BE ADJUSTABLE BY OCCUPANT AT SPACE
TEMPERATURE SENSOR BY PLUS OR MINUS 2-DEGREE FAHRENHEIT (ADJUSTABLE) AND AT OPERATOR WORKSTATION. IN PUBLIC
AREAS SETPOINT SHALL BE INACCESSIBLE. ALL SETPOINTS MAY BE OVERRIDDEN AT THE OPERATOR'S WORKSTATION.
4. CONTROLLER SHALL MAINTAIN SUPPLY AIR VOLUME SETTING REGARDLESS OF SYSTEM STATIC PRESSURE BY DIRECTLY
MEASURING AIR FLOW AND CONTROLLING UNIT DAMPER.
A) MAXIMUM AIR VOLUME SHALL BE PRESET TO EQUAL THE SUM OF ALL ATTACHED DIFFUSERS AND REGISTERS WHICH SHOULD
MATCH THE SCHEDULED MAXIMUM AIR VOLUME FOR EACH TERMINAL UNIT.
B) MINIMUM AIR VOLUME SHALL BE PRESET TO THE VOLUME LISTED IN SCHEDULE.
5. TEMPERATURE CONTROL:
A) CONTROLLER SHALL MODULATE AIR VOLUME BETWEEN MINIMUM AND MAXIMUM SETTINGS TO MAINTAIN SPACE
TEMPERATURE SETPOINT.
B) ON A CALL FOR COOLING, DAMPER SHALL MODULATE OPEN. BOTH REHEAT COIL AND RADIANT PANEL VALVES SHALL BE
CLOSED.
C) ON A CALL FOR HEATING, DAMPER MODULATES CLOSED TO MINIMUM POSITION. REHEAT VALVE MODULATES OPEN FIRST,
THEN ASSOCIATED (LINKED) PREHEAT VALVE IN SEQUENCE TO MAINTAIN SPACE TEMPERATURE SETPOINT.
D) TERMINAL REHEAT COIL CONTROL VALVE SHALL BE 2-WAY VALVES UNLESS OTHERWISE NOTED.
E) EACH RADIANT PANEL CONTROL VALVE SHALL BE 2-WAY VALVES UNLESS OTHERWISE NOTED, AND EACH RADIANT PANEL
SHALL HAVE ITS OWN DEDICATED CONTROL VALVE.
E. CONSTANT VOLUME AIR TERMINAL UNITS WITH REHEAT AND RADIANT PANELS:
1. DIRECT DIGITAL AIRFLOW CONTROLLER, DIFFERENTIAL PRESSURE SENSOR, AND ELECTRONIC DAMPER ACTUATOR SHALL BE
FURNISHED UNDER THIS SECTION BUT SHALL BE FACTORY MOUNTED BY THE TERMINAL UNIT MANUFACTURER. REHEAT AND RADIANT
PANEL CONTROL VALVES SHALL BE FURNISHED UNDER THIS SECTION BUT CAN BE FIELD INSTALLED. THERE ARE A FEW CAV
TERMINAL UNITS WITHOUT REHEAT AND/OR RADIANT PANELS.
2. SPACE COOLING AND HEATING SETPOINTS SHALL HAVE SEPARATE OCCUPIED AND UNOCCUPIED SETTINGS, AND CONTROLLER
SHALL AUTOMATICALLY SHIFT BETWEEN OCCUPIED AND UNOCCUPIED SETTINGS WHEN ASSOCIATED AH IS SHIFTED. SEE
UNOCCUPIED AND OCCUPIED SPACE SETPOINTS SECTIONS OF AH SEQUENCES.
3. IN PATIENT ROOMS, PRIVATE OFFICES, AND SIMILAR SPACES, SETPOINT SHALL BE ADJUSTABLE BY OCCUPANT AT SPACE
TEMPERATURE SENSOR BY PLUS OR MINUS 2-DEGREE FAHRENHEIT (ADJUSTABLE) AND AT OPERATOR WORKSTATION. IN PUBLIC
AREAS SETPOINT SHALL BE INACCESSIBLE. ALL SETPOINTS MAY BE OVERRIDDEN AT THE OPERATOR'S WORKSTATION.
4. CONTROLLER SHALL MAINTAIN SUPPLY AIR VOLUME SETTING REGARDLESS OF SYSTEM STATIC PRESSURE BY DIRECTLY
MEASURING AIR FLOW AND CONTROLLING UNIT DAMPER.
A) CONSTANT AIR VOLUME SHALL BE PRESET TO EQUAL THE SUM OF ALL ATTACHED DIFFUSERS AND REGISTERS WHICH
SHOULD MATCH THE SCHEDULED CONSTANT AIR VOLUME FOR EACH TERMINAL UNIT.
5. TEMPERATURE CONTROL:
A) CONTROLLER SHALL MODULATE DAMPER TO MAINTAIN CONSTANT AIR VOLUME TO MAINTAIN VENTILATION SETPOINT.
B) ON A CALL FOR COOLING, DAMPER MODULATE TO MAINTAIN CONSTANT AIR VOLUME SETPOINT. BOTH REHEAT COIL AND RADIANT
PANEL VALVES SHALL BE CLOSED.
C) ON A CALL FOR HEATING, DAMPER MODULATES TO MAINTAIN CONSTANT AIR VOLUME SETPOINT. REHEAT VALVE MODULATES OPEN
FIRST, THEN ASSOCIATED (LINKED) PREHEAT VALVE IN SEQUENCE TO MAINTAIN SPACE TEMPERATURE SETPOINT.
D) TERMINAL REHEAT COIL CONTROL VALVE SHALL BE 2-WAY VALVES UNLESS OTHERWISE NOTED.
E) EACH RADIANT PANEL CONTROL VALVE SHALL BE 2-WAY VALVES UNLESS OTHERWISE NOTED, AND EACH RADIANT PANEL SHALL
HAVE ITS OWN DEDICATED CONTROL VALVE.
NO SCALE
INPUT/OUTPUT SUMMARY
INPUTS OUTPUTS SYSTEM FEATURES
ANALOG GENERAL
MEASURED CALC DIGITAL ANALOG DIGITAL ALARMS PROGRAMS
System, Apparatus, or Area Point Description
Tem
pera
ture
Rel
. Hum
idity
Flow
Rat
e
Diff
. Pre
ssur
e
Sta
tic P
ress
u re
KW
Mot
or R
PM
Pre
ssur
e
Run
Tim
e
Ent
halp
y
Effi
cien
cy
Lb/H
r
KW
H
Sta
tus
Nor
mal
/Ala
rm
Sm
oke
Ala
rm
Hig
h S
tatic
Pre
ss.
Air
Flow
End
sw
itch
Low
Pre
ss. A
larm
Hig
h Le
vel A
larm
Low
Lev
el A
l arm
Flow
Sw
itch
Sta
tus
Dam
per P
osi ti
on
Val
ve P
ositi
o n
Mot
or S
peed
Set
Poi
nt A
dj
Off-
On
Ope
n-C
lose
Res
et
Failu
re
Hig
h V
alue
Low
Val
ue
Tim
e S
ched
u lin
g
Dem
and
Lim
iting
Ent
halp
y O
pt
Sm
oke
Cnt
Tren
d
Ala
rm In
stru
c t
Nig
ht S
et-b
ack
Mor
ning
War
m-u
p
Sta
tic P
ress
u re
Opt
.
Tem
p. R
eset
Opt
.
Lead
/Lag
Col
or G
raph
i c
Supplementary Notes
AHU-70 X X X X X X
Return Air X X X X
Exhaust Air Fan (EF- 37,41) X X X X
Outside Air X X
Outside Air Damper X X
Return Air Damper
Mixed Air X
Prefilter X
Cooling Coil X X
Supply Air Fan X X X X
SA Fan Variable Speed Drive X X X
Supply Air X X X X X
Smoke Dampers X X
AIR TERMINAL UNITS X X X X X
Supply Air X X X
Reheat X
Space X
RADIANT HEATING PANEL
Reheat
Space
KW
H
GP
M
WITH 4 INCH PIPING. SEE SHEET MP-404.2. REPLACE EXISTING 3 INCH HWS/R PIPING FROM TEE TOWARDS EAST CHASE
DIAGRAM NOTES:
Tota
lizat
ion
X X X
X
X
X
X
X X X X
X
X
XX X
NO SCALE
2
BAS (JOHNSON CONTROLS FACILITY EXPLORER).1. THE NEW HVAC SYSTEM CONTROLS SHALL BE COMPATABLE WITH THE EXISTING
NOTES FOR EXISTING/NEW CONTROL SYSTEM INTERFACE:
1
4
3. TIE EXISTING BRANCH PIPING INTO NEW 4 INCH RISER. SEE SHEET MP-406.4. END OF NEW 4 INCH RISER. TIE INTO EXISTING RISER BELOW NEW 6TH FLOOR
BRANCH.5. REPLACE EXISTING HWS VALVES WITH NEW COMBINATION BALANCING VALVE-
ISOLATION VALVE WITH MEMORY STOP. REPLACE EXISTING HWR VALVE WITHNEW ISOLATION VALVE. SEE SHEETS 401-406 FOR MORE DETAILS REGARDING
3
REPLACEMENT OF BALANCING VALVES.
1. TAB CONTRACTOR SHALL PERFORM A PRELIMINARY HOT WATER BALANCE
51 5
THE PRELIMINARY HOT WATER BALANCE REPORT SHALL BE ISSUED TO THE
AND RECORD FLOWS AT EACH EXISTING HOT WATER BALANCE VALVE BEFORE
SERVED ARE IN A MAX DESIGN FLOW FULL HEATING MODE OF OPERATION.IT IS REPLACED AS SHOWN ON RISER DIAGRAM WHEN HEATING SYSTEMS
RESIDENT ENGINEER FOR EVALUATION. AFTER NEW 4 INCH HOT WATER PIPE AND
BALANCE NEW HOT WATER VALVES TO MATCH FLOWS ON PRELIMINARY HOTNEW HOT WATER BALANCE VALVES ARE PROVIDED, TAB CONTRACTOR SHALL
WATER BALANCE REPORT OR TO NEW FLOW RATES AS DIRECTED BY THERESIDENT ENGINEER WHO EVALUATED THE PRELIMINARY REPORT.
NO SCALE
DIAGRAM NOTES:
1
1. REPLACE EXISTING AIR SEPARATOR WITH NEW LINE SIZE SPIROTHERM OR EQUAL COMBINATION AIR/DIRT SEPARATOR.PUMP SUCTION PIPING SHALL BE ADJUSTED TO ELEVATION THAT MATCHES WITH NEW AIR/DIRT SEPARATOR CONNECTIONS.
2. EXISTING FILTER/CHEMICAL TREATMENT SYSTEM TO BE DEMOLISHED BACK TO TAPS AT THE HWS PUMP DISCHARGE ANDTHE RELIEF VALVE. CHEMICAL BY-PASS FEEDER TO BE RETAINED AND PROVIDED TO THE VA.
3. NEW SHUTOFF VALVE AND CAPS TO BE INSTALLED AT EXISTING CHEMICAL TREATMENT TAPS FOR FUTURE INSTALLATIONOF CHEMICAL TREATMENT SYSTEM BY VA. INSULATE WHERE SHUTOFF VALVE/CAPS ARE ADDED AND WHERE INSULATIONIS DISTURBED ON EXISTING HWS PIPING.
2
3
3
1 5
1 5
1 5
1 5
1 5
1 5
1 5
1 5 51
51
51
51
51
51
X
EF Fan Variable Speed Drive X X X
X X
X
1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
10/05/18RESPONSIBLE CHARGE
10/05/18COVERING HVAC DESIGN
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/5
/2018 5
:57:5
3 P
M
MH-601
HVAC CONTROL AND DETAILS I
10/05/18 PP KGRevisions: Date:
SMOKE AND COMBINATION FIRE/SMOKE DAMPER SCHEDULE
MARK LOCATIONFAN
SYSTEM
SYSTEMAND/ORSERVICE
DUCT SIZEDUCT PRESSURE
CLASS REMARKS
IN [mm] IN WG [Pa]
FD-1 C6001 SF-70 AHU-70 24x8 [600 x 200] 3 [ 750 ] 2HR FIRE
FD-2 C6032 SF-70 AHU-70 24x8 [600 x 200] 3 [ 750 ] 2HR FIRE
FD-3 C6031 SF-70 AHU-70 8x8 [200 x 200] 3 [ 750 ] 2HR FIRE + SMOKE
FD-4 C6029 SF-70 AHU-70 24x8 [600 x 200] 3 [ 750 ] 2HR FIRE
FD-5 C7040 SF-70 AHU-70 20x16 [500 x 400] 3 [ 750 ] 2HR FIRE + SMOKE
FD-6 C6031 EF-37 AHU-70 20x10 [500 x 250] 3 [ 750 ] 2HR FIRE + SMOKE
FD-7 C6031 RF AHU-70 34x10 [850 x 250] 3 [ 750 ] 2HR FIRE
FD-8 C6029 RF AHU-70 34x10 [850 x 250] 3 [ 750 ] 2HR FIRE
FD-9 C7040 EF-41 AHU-70 20x10 [508 x 254] 3 [ 750 ] 2HR FIRE + SMOKE
AIR DEVICE SCHEDULE (SUPPLY)
MARK TYPE
AIR FLOWMAX APD
MOUNTING
PANEL/FRAME SIZE NECK SIZE
NC DAMPER FINISH REMARKSMIN MAXIN x IN [mm x mm] IN [mm ]
CFM [L/s] CFM [L/s] IN WG [Pa]
SD-1 SQUARE HIGH PERFORMANCE CONE 40 [ 19 ] 200 [ 94 ] 0.110 [ 28 ] CEILING 24 X 24 [ 600 X 600 ] 6 ø [ 150 ] 30 OBD WHITE 1
SD-2 SQUARE HIGH PERFORMANCE CONE 205 [ 97 ] 360 [ 170 ] 0.110 [ 28 ] CEILING 24 X 24 [ 600 X 600 ] 8 ø [ 200 ] 30 OBD WHITE 1
NOTES
1. PROVIDE SQUARE TO ROUND ADAPTER WHERE REQUIRED.
AIR DEVICE SCHEDULE (RETURN+EXHAUST)
MARK TYPE SIZE
AIR FLOWMAX APD
MOUNTING NC DAMPER FINISH REMARKSMIN MAX
CFM [L/s] CFM [L/s] IN WG [Pa]
RG-1 EGGCRATE 6X6 50 [ 24 ] 95 [ 45 ] 0.11 28 CEILING 20 OBD WHITE 1
RG-2 EGGCRATE 8X8 100 [ 47 ] 125 [ 59 ] 0.11 28 CEILING 20 OBD WHITE 1
RG-3 EGGCRATE 12X12 130 [ 61 ] 280 [ 130 ] 0.11 28 CEILING 20 OBD WHITE 1
RG-4 EGGCRATE 18X18 290 [ 140 ] 590 [ 280 ] 0.11 28 CEILING 20 OBD WHITE 1
RG-5 EGGCRATE 24X24 600 [ 280 ] 925 [ 440 ] 0.11 28 CEILING 20 OBD WHITE 1
EG-1 EGGCRATE 6X6 50 [ 24 ] 95 [ 45 ] 0.11 28 CEILING 20 OBD WHITE 1
EG-2 EGGCRATE 8X8 100 [ 47 ] 125 [ 59 ] 0.11 28 CEILING 20 OBD WHITE 1
EG-3 EGGCRATE 12X12 130 [ 61 ] 280 [ 130 ] 0.11 28 CEILING 20 OBD WHITE 1
EG-4 EGGCRATE 18X18 290 [ 140 ] 590 [ 280 ] 0.11 28 CEILING 20 OBD WHITE 1
EG-5 EGGCRATE 24X24 600 [ 280 ] 925 [ 440 ] 0.11 28 CEILING 20 OBD WHITE 1
NOTE
1. PROVIDE SQUARE TO ROUND ADAPTER WHERE REQUIRED
PUMP SCHEDULE
MARK LOCATION
AREAAND/ORBLDG
SERVED
SYSTEM AND/ORSERVICE
TYPE
CIRCULATING FLUIDMIN %EFF
ELECTRICAL MOTOR
REMARKSFLUID
FLOW HEAD TEMPERATURESP GR
NOMINAL POWERPHASE VOLT MAX RPM
SPEEDCONTROLGPM [L/s] FT [kPa] °F [°C] HP [kW]
P-1, P-2 PENTHOUSE ALL HEATING WATEREND
SUCTIONBUILDING HEATING
WATER150 [ 10 ] 50 [ 800 ] 180 [ 82 ] 0.975 73.5 5 [ 4 ] 3 230/460 1800 CONSTANT ----
VFD
S
TS
C CONTROLLER
CONTROL VALVE (2-WAY
OR 3-WAY-SEE PLANS
AND FLOW DIAGRAMS)
TEMPERATURE SENSOR
FZ-1
MD
MOTOR OPERATED SMOKE DAMPER
COIL (TYPE INDICATED)
LOW LIMIT THERMOSTAT
MOTOR OPERATED DAMPER
STATIC PRESSURE GAUGESP
SMOKE DETECTOR
SPACE TEMPERATURE SENSOR
CONTROL SYMBOLS
AIR FLOW SENSOR
VARIABLE FREQUENCY DRIVE
T
TEMPERATURE SENSOR
(AVERAGING STEM)
(RIGID STEM)
TS
STATIC PRESSURESPSSENSOR
DPGAUGEDIFFERENTIAL PRESSURE
ES
SD
END SWITCH
PSL
PSH
PRESSURE SWITCH HIGH
PRESSURE SWITCH LOW
AIR HANDLING UNIT
FILTERS COIL
CH
CH
R
NO SCALE AH-70
TEMPERED AIR
DP
TS-1
SUPPLYFAN
C
TS-2
SUPPLYAIR
COOLING
EXHAUSTAIR
ES
EXHAUSTFAN
RETURN AIR
C
S
MD
SD
VFD
C
STATICPRESSURESENSOR
PSH
FZ-1
C
MD
T
FROM AHU-1
AIR FLOW STATION
VFD
C
PSL
PSL-1
EXHAUST FANNO SCALE EF-37/EF-41
(NC)
(NC)
(NC)
(NC TO COIL)
TS
TS
SPS
TS
TS
REMOTE OUTSIDEOUTSIDE AIR
TEMPERATURESENSOR
SUPPLYAIR
ES
SD
S
(NC)
SUPPLYAIR
ES
SD
S
(NC)
DPS DIFFERENTIAL PRESSURE SENSOR
MD
DPS
C
ES
SD
S
(NC)
(FD-3&5)
(FD-3&5)
(FD-4)
(NO)
S
(FD-6&9)
ES SD
S
(NC)
(FD-7&8)
AIR FILTER SCHEDULE
MARK LOCATIONAREA AND/OR BLDG
SERVED
SYSTEMAND/ORSERVICE
MERVRATING
AIR FLOWAPD
HOUSINGTYPE
CARTRIDGES
INITIAL CHANGEOVER#
SIZEARRANGEMENT REMARKS
CFM [L/s] IN [mm] IN [mm] IN [mm]
PF-70A C7040C-WING, E, 6TH & 7TH
FLOORAHU-70 8 13000 [ 6100 ] 0.5 [ 13 ] 1.2 [ 30 ] SIDE 3 12 x 24 x 2 -----
PF-70B C7040C-WING, E, 6TH & 7TH
FLOORAHU-70 8 13000 [ 6100 ] 0.5 [ 13 ] 1.2 [ 30 ] SIDE 8 20 x 20 x 2 -----
AF-70A C7040C-WING, E, 6TH & 7TH
FLOORAHU-70 15 13000 [ 6100 ] 0.6 [ 15 ] 1 [ 25 ] SIDE 3 12 x 24 x 12 -----
AF-70B C7040C-WING, E, 6TH & 7TH
FLOORAHU-70 15 13000 [ 6100 ] 0.6 [ 15 ] 1 [ 25 ] SIDE 8 20 x 20 x 12 -----
CHILLED WATER COOLING COIL SCHEDULE
MARK LOCATIONAREA AND/OR BLDG
SERVED
SYSTEMAND/ORSERVICE
AIR FLOWMAX FACEVELOCITY
APDEAT LAT
TOTAL CAPACITY SENSIBLE CAPACITYCHILLED WATER
REMARKSDb Wb Db Wb FLOW EWT LWT WPD
CFM [L/s] FPM [M/s] IN WG [Pa] °F [°C] °F [°C] °F [°C] °F [°C] MBH [kW] MBH [kW] GPM [L/s] °F [°C] °F [°C] FT [M]
CC-70 C7040C-WING, E, 6TH & 7TH
FLOORAHU-70 13000 [ 6100 ] 481 [ 2 ] 0.45 [ 110 ] 68 [ 20 ] 60 [ 16 ] 54 [ 12 ] 53.4 [ 12 ] 209 [ 61 ] 188 [ 55 ] 42 [ 3 ] 44 [ 7 ] 54 [ 12 ] 10.9 [ 3 ] -----
FAN SCHEDULE
MARK LOCATIONAREA AND/OR BLDG
SERVED
SYSTEMAND/ORSERVICE
AIR FLOW TSP
FAN MOTOR ELECTRICAL
CONTROLSEQUENCE
REMARKSTYPE WHEEL CLASS
ARRANGEMENT,ROTATION, ANDDISCHARGE
DIAMETERMIN % EFF DRIVE
FAN MAXRPM
NOMINAL POWERPHASE VOLT RPM
SPEEDCONTROL
CFM [L/s] IN [Pa] IN [mm] BHP HP [kW]
SF-70 C7040C-WING, EAST, 6TH & 7TH
FLOORAHU-70 13000 [ 6100 ] 7.7 [ 1900 ] CENTRIFUGAL CF II PLENUM MANUF MANUF 66% DIRECT 3657 24 30 [ 22 ] 3 460 3600 VARIABLE 1,2
EF-37 EAST CHASE, 7TH FLOOR C-WING, EAST, 6TH FLOOR AHU-70 1770 [ 840 ] 0.9 [ 230 ] CENTRIFUGAL BI I INLINE MANUF MANUF 48% DIRECT 1725 0.5 1 [ 1 ] 3 460 1725 VARIABLE 1
EF-41 EAST CHASE, 8TH FLOOR C-WING, EAST, 7TH FLOOR AHU-70 2350 [ 1100 ] 1.6 [ 400 ] CENTRIFUGAL BI I INLINE MANUF MANUF 55% DIRECT 1725 1 2 [ 2 ] 3 460 1725 VARIABLE 1
NOTE
1. PROVIDE LOCKABLE PANEL WITH SINGLE POINT CONNECTION
2. FOUR (4) FANS TOTAL. HP DATA REFLECTS TOTAL OF ALL FOUR.
AIR HANDLING UNIT SCHEDULE
MARK LOCATION AREA AND/OR BLDG SERVED TYPE AIR FLOW
AIR FLOWSUPPLY FAN
MARKRETURN OR
RELIEF FAN MARKEXHAUSTFAN MARK
PREFILTERMARK
AFTER FILTERMARK
FINALFILTER MARK
HEATRECOVERY
MARK
PREHEATCOIL MARK
COOLINGCOIL MARK
REHEATCOIL
HUMIDIFIERMARK
REMARKSSUPPLY MIN OA RETURN
CFM [L/s] CFM [L/s] CFM [L/s]
AHU-70 C7040 C-WING, E, 6TH & 7TH FLOOR HORIZONTAL DRAW THRU VAV 13000 [ 6100 ] 4120 [ 1900 ] 8880 [ 4200 ] SF-70 N/A EF-37, EF-41 PF-70A/B AF-70 N/A N/A N/A CC-70 AT TU N/A ----
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
10/05/18RESPONSIBLE CHARGE
10/05/18COVERING HVAC DESIGN
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/5
/2018 5
:57:5
3 P
M
MH-602
HVAC CONTROL AND DETAILS II
10/05/18 PP KGRevisions: Date:
AHU-70 DUCT AIR TERMINAL UNIT SCHEDULE
MARK LOCATION
AREAAND/ORROOM
SERVED
SYSTEM AIRHANDLING
DUCT INLETSIZE
AIR FLOW HOT WATER HEATING COIL
PERIMETERSUPPLEMENTAL HEAT LINK
REMARKS90% EFFICIENT MAX MIN EAT EWT FLOW MAX WPD
PIPE RUNOUTSIZE TO COIL
MIN BTUH
IN CFM [L/s] CFM [L/s] CFM [L/s] °F °F GPM FT IN BTUH
VAV-1 C6001 C6001 AHU-70 10 x 8 1056 [ 500 ] 950 [ 450 ] 501 [ 240 ] 55 180 1.4 1 0.75 13,527 RP-01, RP-02, RP-03, RP-04 1,2,4,5
VAV-2 C6002 C6002 AHU-70 10 x 8 289 [ 140 ] 260 [ 120 ] 87 [ 41 ] 55 180 0.5 1 0.75 2,349 RP-05, RP-06 1,2,4,5
VAV-62 C6002 C6002A AHU-70 8 x 6 122 [ 58 ] 110 [ 52 ] 55 [ 26 ] 55 180 0.5 1 0.75 1,485 RP-07 1,2,4,5
VAV-5 C6006 C6006 AHU-70 8 x 6 189 [ 89 ] 170 [ 80 ] 169 [ 80 ] 55 180 0.5 1 0.75 4,563 NONE 1,2,4,5
VAV-6 C6007 C6007 AHU-70 10 x 8 722 [ 340 ] 650 [ 310 ] 249 [ 120 ] 55 180 0.7 1 0.75 6,723 RP-08, RP-09 1,2,4,5
VAV-7 C6007 C6008 AHU-70 10 x 8 611 [ 290 ] 550 [ 260 ] 164 [ 77 ] 55 180 0.5 1 0.75 4,428 RP-10, RP-11 1,2,4,5
VAV-9 C6-24 C6009 AHU-70 8 x 6 344 [ 160 ] 310 [ 150 ] 94 [ 44 ] 55 180 0.5 1 0.75 2,538 RP-12 1,2,4,5
VAV-10 C6-24 C6010 AHU-70 8 x 6 289 [ 140 ] 260 [ 120 ] 95 [ 45 ] 55 180 0.5 1 0.75 2,565 RP-13, RP-14 1,2,4,5
VAV-11 C6-24 C6011 AHU-70 8 x 6 122 [ 58 ] 110 [ 52 ] 55 [ 26 ] 55 180 0.5 1 0.75 1,485 RP-15 1,2,4,5
VAV-12 C6013 C6012 AHU-70 8 x 6 344 [ 160 ] 310 [ 150 ] 106 [ 50 ] 55 180 0.5 1 0.75 2,862 RP-16, RP-17 1,2,4,5
VAV-13 C6014 C6013 AHU-70 8 x 6 333 [ 160 ] 300 [ 140 ] 106 [ 50 ] 55 180 0.5 1 0.75 2,862 RP-18 1,2,4,5
VAV-14 C6015 C6014 AHU-70 8 x 6 344 [ 160 ] 310 [ 150 ] 103 [ 49 ] 55 180 0.5 1 0.75 2,781 RP-19 1,2,4,5
VAV-15 C6016 C6015 AHU-70 8 x 6 333 [ 160 ] 300 [ 140 ] 109 [ 51 ] 55 180 0.5 1 0.75 2,943 RP-20 1,2,4,5
VAV-16 C6-24 C6016 AHU-70 10 x 8 656 [ 310 ] 590 [ 280 ] 224 [ 110 ] 55 180 0.6 1 0.75 6,048 RP-21, RP-22 1,2,4,5
VAV-17 C6-23 C6017 AHU-70 8 x 6 89 [ 42 ] 80 [ 38 ] 64 [ 30 ] 55 180 0.5 1 0.75 1,728 NONE 1,2,4,5
VAV-18 C6019 C6019 AHU-70 10 x 8 811 [ 380 ] 730 [ 340 ] 443 [ 210 ] 55 180 1.2 1 0.75 11,961 RP-23, RP-24, RP-25, RP-26 1,2,4,5
CAV-21 C6-23 C6020 AHU-70 8 x 6 232 [ 110 ] 209 [ 99 ] 209 [ 99 ] 55 180 0.6 1 0.75 5,643 NONE 1,2,3,4
VAV-23 C6021 C6021 AHU-70 8 x 6 156 [ 74 ] 140 [ 66 ] 64 [ 30 ] 55 180 0.5 1 0.75 1,728 RP-27 1,2,4,5
VAV-25 C6020 C6022 AHU-70 8 x 6 200 [ 94 ] 180 [ 85 ] 93 [ 44 ] 55 180 0.5 1 0.75 2,511 RP-28 1,2,4,5
VAV-27 C6020 C6023 AHU-70 8 x 6 122 [ 58 ] 110 [ 52 ] 61 [ 29 ] 55 180 0.5 1 0.75 1,647 RP-29 1,2,4,5
VAV-29 C6024 C6024 AHU-70 8 x 6 156 [ 74 ] 140 [ 66 ] 74 [ 35 ] 55 180 0.5 1 0.75 1,998 RP-30, RP-31 1,2,4,5
VAV-28 C6025 C6025 AHU-70 8 x 6 244 [ 120 ] 220 [ 100 ] 128 [ 60 ] 55 180 0.5 1 0.75 3,456 RP-32, RP-33 1,2,4,5
VAV-26 C6020 C6026 AHU-70 8 x 6 211 [ 100 ] 190 [ 90 ] 94 [ 44 ] 55 180 0.5 1 0.75 2,538 RP-34 1,2,4,5
VAV-24 C6027 C6027 AHU-70 8 x 6 211 [ 100 ] 190 [ 90 ] 93 [ 44 ] 55 180 0.5 1 0.75 2,511 RP-35 1,2,4,5
VAV-22 C6029 C6028 AHU-70 8 x 6 211 [ 100 ] 190 [ 90 ] 92 [ 43 ] 55 180 0.5 1 0.75 2,484 RP-36 1,2,4,5
VAV-20 C6029 C6029 AHU-70 8 x 6 311 [ 150 ] 280 [ 130 ] 151 [ 71 ] 55 180 0.5 1 0.75 4,077 RP-37 1,2,4,5
VAV-19 C6-23 C6030 AHU-70 10 x 8 522 [ 250 ] 470 [ 220 ] 235 [ 110 ] 55 180 0.6 1 0.75 6,345 RP-38, RP-39 1,2,4,5
CAV-61 C6031 C6031 AHU-1 8 x 8 400 [ 190 ] 360 [ 170 ] 360 [ 170 ] 53 - - - - - NONE 1,3,5
VAV-3 C6-23 C6032 AHU-70 8 x 6 89 [ 42 ] 80 [ 38 ] 64 [ 30 ] 55 180 0.5 1 0.75 1,728 NONE 1,2,4,5
VAV-4 C6002 C6-23 AHU-70 8 x 6 189 [ 89 ] 170 [ 80 ] 167 [ 79 ] 55 180 0.5 1 0.75 4,509 NONE 1,2,4,5
VAV-8 C6008 C6-24 AHU-70 10 x 8 217 [ 100 ] 195 [ 92 ] 135 [ 64 ] 55 180 0.5 1 0.75 3,645 NONE 1,2,4,5
VAV-64 C6-25 C6-25 AHU-70 8 x 8 307 [ 140 ] 276 [ 130 ] 276 [ 130 ] 55 180 0.7 1 0.75 7,452 NONE 1,2,4,5
VAV-60 C7005 C7001 AHU-70 8 x 6 167 [ 79 ] 150 [ 71 ] 87 [ 41 ] 55 180 0.5 1 0.75 2,349 RP-40 1,2,4,5
VAV-59 C7005 C7003 AHU-70 8 x 6 233 [ 110 ] 210 [ 99 ] 145 [ 68 ] 55 180 0.5 1 0.75 3,915 RP-41, RP-42 1,2,4,5
VAV-58 C7005 C7005 AHU-70 8 x 6 689 [ 330 ] 620 [ 290 ] 303 [ 140 ] 55 180 0.8 1 0.75 8,181 RP-43, RP-44, RP-47 1,2,4,5
VAV-55 C7007 C7007 AHU-70 10 x 8 722 [ 340 ] 650 [ 310 ] 499 [ 240 ] 55 180 1.3 1 0.75 13,473 RP-48 1,2,4,5
VAV-56 C7007 C7007 AHU-70 8 x 6 156 [ 74 ] 140 [ 66 ] 108 [ 51 ] 55 180 0.5 1 0.75 2,916 RP-49 1,2,4,5
VAV-57 C7007 C7009/C7-11 AHU-70 8 x 6 333 [ 160 ] 300 [ 140 ] 198 [ 93 ] 55 180 0.5 1 0.75 5,346 RP-45, RP-46 1,2,4,5
VAV-49 C7011 C7011 AHU-70 8 x 6 291 [ 140 ] 262 [ 120 ] 102 [ 48 ] 55 180 0.5 1 0.75 2,754 RP-68 1,2,4,5
VAV-50 C7012 C7012 AHU-70 8 x 6 300 [ 140 ] 270 [ 130 ] 103 [ 49 ] 55 180 0.5 1 0.75 2,781 RP-69 1,2,4,5
VAV-51 C7013 C7013/C7014 AHU-70 8 x 6 444 [ 210 ] 400 [ 190 ] 114 [ 54 ] 55 180 0.5 1 0.75 3,078 RP-70 1,2,4,5
VAV-52 C7015 C7015 AHU-70 8 x 6 300 [ 140 ] 270 [ 130 ] 105 [ 50 ] 55 180 0.5 1 0.75 2,835 RP-71 1,2,4,5
VAV-53 C7016 C7016 AHU-70 8 x 6 311 [ 150 ] 280 [ 130 ] 108 [ 51 ] 55 180 0.5 1 0.75 2,916 RP-72, RP-73 1,2,4,5
VAV-48 C7017 C7017 AHU-70 8 x 6 278 [ 130 ] 250 [ 120 ] 105 [ 50 ] 55 180 0.5 1 0.75 2,835 RP-75, RP-76 1,2,4,5
VAV-47 C7018 C7018 AHU-70 8 x 6 178 [ 84 ] 160 [ 76 ] 100 [ 47 ] 55 180 0.5 1 0.75 2,700 RP-77 1,2,4,5
VAV-46 C7019 C7019 AHU-70 8 x 6 178 [ 84 ] 160 [ 76 ] 105 [ 50 ] 55 180 0.5 1 0.75 2,835 RP-78 1,2,4,5
VAV-45 C7020 C7020 AHU-70 8 x 6 278 [ 130 ] 250 [ 120 ] 103 [ 49 ] 55 180 0.5 1 0.75 2,781 RP-79 1,2,4,5
VAV-44 C7021 C7021 AHU-70 8 x 6 278 [ 130 ] 250 [ 120 ] 98 [ 46 ] 55 180 0.5 1 0.75 2,646 RP-80 1,2,4,5
VAV-43 C7022 C7022 AHU-70 8 x 6 278 [ 130 ] 250 [ 120 ] 92 [ 43 ] 55 180 0.5 1 0.75 2,484 RP-81 1,2,4,5
VAV-31 C7026 C7026 AHU-70 8 x 6 233 [ 110 ] 210 [ 99 ] 126 [ 59 ] 55 180 0.5 1 0.75 3,402 RP-50 1,2,4,5
VAV-32 C7027 C7027 AHU-70 8 x 6 156 [ 74 ] 140 [ 66 ] 92 [ 43 ] 55 180 0.5 1 0.75 2,484 RP-51 1,2,4,5
VAV-33 C7028 C7028 AHU-70 8 x 6 156 [ 74 ] 140 [ 66 ] 92 [ 43 ] 55 180 0.5 1 0.75 2,484 RP-52 1,2,4,5
VAV-35 C7029 C7029 AHU-70 8 x 6 156 [ 74 ] 140 [ 66 ] 92 [ 43 ] 55 180 0.5 1 0.75 2,484 RP-53 1,2,4,5
VAV-38 C7030 C7030 AHU-70 8 x 6 289 [ 140 ] 260 [ 120 ] 136 [ 64 ] 55 180 0.5 1 0.75 3,672 RP-54, RP-55 1,2,4,5
VAV-40 C7031 C7031 AHU-70 8 x 6 156 [ 74 ] 140 [ 66 ] 92 [ 43 ] 55 180 0.5 1 0.75 2,484 RP-56 1,2,4,5
VAV-41 C7032 C7032 AHU-70 8 x 6 189 [ 89 ] 170 [ 80 ] 92 [ 43 ] 55 180 0.5 1 0.75 2,484 RP-57, RP-58 1,2,4,5
VAV-42 C7033 C7033 AHU-70 8 x 6 267 [ 130 ] 240 [ 110 ] 115 [ 54 ] 55 180 0.5 1 0.75 3,105 RP-60, RP-61 1,2,4,5
VAV-39 C7-9 C7035 AHU-70 8 x 6 311 [ 150 ] 280 [ 130 ] 186 [ 88 ] 55 180 0.5 1 0.75 5,022 RP-62, RP-63 1,2,4,5
VAV-36 C7-9 C7037 AHU-70 8 x 6 311 [ 150 ] 280 [ 130 ] 176 [ 83 ] 55 180 0.5 1 0.75 4,752 RP-65 1,2,4,5
VAV-37 C7-9 C7037A/C7-9 AHU-70 8 x 6 244 [ 120 ] 220 [ 100 ] 115 [ 54 ] 55 180 0.5 1 0.75 3,105 RP-59, RP-64 1,2,4,5
VAV-34 C7039 C7039 AHU-70 8 x 6 222 [ 100 ] 200 [ 94 ] 85 [ 40 ] 55 180 0.5 1 0.75 2,295 RP-66, RP-67 1,2,4,5
CAV-65 C7040 C7040 AHU-70 6 x 8 222 [ 100 ] 200 [ 94 ] 200 [ 94 ] 53 - - - - - NONE 1,3,5
CAV-54 C7-10 C7-10 AHU-70 10 x 8 454 [ 210 ] 409 [ 190 ] 409 [ 190 ] 55 180 1.1 1 0.75 11,043 RP-74 1,3,4,5
VAV-30 C7-9 C7-9 AHU-70 8 x 6 329 [ 160 ] 296 [ 140 ] 229 [ 110 ] 55 180 0.6 1 0.75 6,183 NONE 1,2,4,5
NOTES
1. NO ADDITIONAL SOUND ATTENUATION REQUIRED.
2. CONTROL TYPE IS VAV; DISCHARGE AIR TEMPURATURE MAX 80°F
3. CONTROL TYPE IS CAV; DISCHARGE AIR TEMPURATURE MAX 80°F
4. REHEAT BY HOT WATER
5. VA DESIRES BOX EFFICIENCY BETWEEN 75% AND 90%. BOX EFFICIENCY EXAMPLE: 950 CFM/0.90 = 1056 CFM < VAV-1 BOX AIRFLOW RANGE SELECTION < 950 CFM/0.75 = 1267 CFMCHECKS: 0.90 X 1056 CFM = 950 CFM AND 0.75 x 1267 CFM = 950
CFM. ALSO 950/1056 = 0.90 AND 950/1267 = 0.75. SET UP VAV-1 BOX CAPABLE OF 1056 CFM TO 1267 CFM AT 950 CFM.
6. SIZE BOXES BASED OM 90% EFFICIENT AIRFLOW BUT BALANCE BOX AT MAX AIRFLOW.
RADIANT CEILING PANEL SCHEDULE (HYDRONIC )
MARKROOM
LOCATIONAREA SERVED
PANEL SIZE
HEATING
REMARKSHEATING CAPACITY EWT LWTHOT WATERFLOWRATE
WPD
IN [mm] BTUH [W] °F [°C] °F [°C] GPM [L/m] FT [kPa]
RP-1 C6001 LEARNERS 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10Basis: Sigma SLC,
Typical1-PASS
RP-2 C6001 LEARNERS 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-3 C6001 LEARNERS 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-4 C6001 LEARNERS 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-5 C6002 MD OFFICES 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-6 C6002 MD OFFICES 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-7 C6003 CHIEF 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-8 C6005 CONF RM 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-9 C6005 CONF RM 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-10 C6008 PHYS 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-11 C6008 PHYS 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-12 C6009 LEARNERS 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-13 C6010 NP 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-14 C6010 NP 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-15 C6011 CHIEF 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-16 C6012 RN 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-17 C6012 RN 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-18 C6013 LEARNERS 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-19 C6014 PHYS 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-20 C6015 MD OFFICE 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-21 C6016 MD OFFICES 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-22 C6016 MD OFFICES 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-23 C6019 MSAs 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-24 C6019 MSAs 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-25 C6019 MSAs 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-26 C6019 MSAs 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-27 C6021 BUS MNGR 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-28 C6022 CONFERENCE 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-29 C6023 PRACTICE MNGR 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-30 C6024 CHIEF 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-31 C6024 CHIEF 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-32 C6025 CHIEF 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-33 C6025 CHIEF 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-34 C6026 N CHIEF 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-35 C6027 N CHIEF 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-36 C6028 MSA SUPV 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-37 C6029 PSA 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-38 C6030 MD OFFICE 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-39 C6030 MD OFFICE 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-40 C7001 LOCKERS 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-41 C7003 LOCKERS 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-42 C7003 LOCKERS 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-43 C7005 BREAK RM/MAIL RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-44 C7005 BREAK RM/MAIL RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-45 C7-9 CORRIDOR 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-46 C7-9 CORRIDOR 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-47 C7007 WAITING ROOM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-48 C7007 WAITING ROOM 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-49 C7007 WAITING ROOM 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-50 C7026 TEAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-51 C7027 EXAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-52 C7028 EXAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-53 C7029 EXAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-54 C7030 TEAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-55 C7030 TEAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-56 C7031 EXAM RM 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-57 C7032 EXAM RM 48 X 24 [ 1219 X 610 ] 1856 [ 540 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.16 0.50 8-PASS
RP-58 C7032 EXAM RM 48 X 24 [ 1219 X 610 ] 1856 [ 540 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.16 0.50 8-PASS
RP-59 C7-11 CORRIDOR 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-60 C7033 EXAM RM 48 X 24 [ 1219 X 610 ] 1856 [ 540 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.16 0.50 8-PASS
RP-61 C7033 EXAM RM 48 X 24 [ 1219 X 610 ] 1856 [ 540 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.16 0.50 8-PASS
RP-62 C7035 EXAM-PROC 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-63 C7035 EXAM-PROC 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-64 C7038 TOILET 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-65 C7037 EXAM-PROC 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-66 C7039 CLEAN STORAGE 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-67 C7039 CLEAN STORAGE 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-68 C7011 EXAM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-69 C7012 EXAM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-70 C7013 TEAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-71 C7015 EXAM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-72 C7016 EXAM 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-73 C7016 EXAM 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-74 C7-10 CORRIDOR 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-75 C7017 EXAM 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-76 C7017 EXAM 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-77 C7018 TEAM RM 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-78 C7019 EXAM 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS
RP-79 C7020 EXAM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-80 C7021 TEAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
RP-81 C7022 EXAM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/6
/2018 3
:19:1
1 P
M
MH-603
MECHANICAL SCHEDULE I
10/05/18 PP KGRevisions: Date:
ROOM AIR BALANCE SCHEDULE
ROOM NO ROOM NAMEAIR
HANDLINGUNIT NO
TERMINAL UNITINDIVIDUALROOM TEMP
CONTROL
SUPPLY RETURN OR EXHAUSTROOM AIR
FLOW ROOM AIRBALANCE
NET INFILTRATIONNET
EXFILTRATIONREMARKSROOM AIR FLOW # OF AIR
DEVICESAIR DEVICE MARK
SUPPLYFAN
RETURN OREXHAUST
(R/E)
ROOM AIR FLOW # OF AIRDEVICES
AIR DEVICE MARK
RETURNOR
EXHAUSTFANCFM L/S CFM L/S CV VAV CFM [L/s] CFM [L/s]
C6001 LEARNERS AHU-70 VAV-1 Y 950 [ 450 ] 4 SD-2 SF-70 R 950 [ 450 ] 1 RG-5 X 0 0 [ ] 0 [ ] - - - -
C6002 MD OFFICES AHU-70 VAV-2 Y 260 [ 120 ] 3 SD-1 SF-70 R 260 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C6002A CHIEF AHU-70 VAV-62 Y 110 [ 52 ] 1 SD-1 SF-70 R 110 [ 52 ] 1 RG-2 X 0 0 [ ] 0 [ ] - - - -
C6004 TLT RM N/A N/A N 0 [ ] 0 N/A N/A E 75 [ 35 ] 1 EG-1 EF-37 X - - 75 [ 35 ] 0 [ ] - - - -
C6005 TLT RM N/A N/A N 0 [ ] 0 N/A N/A E 75 [ 35 ] 1 EG-1 EF-37 X - - 75 [ 35 ] 0 [ ] - - - -
C6006 BREAK RM AHU-70 VAV-5 Y 170 [ 80 ] 1 SD-1 SF-70 E 270 [ 130 ] 1 EG-3 EF-37 X - 100 [ 47 ] 0 [ ] - - - -
C6007 CONF RM AHU-70 VAV-6 Y 650 [ 310 ] 3 SD-2 SF-70 R 650 [ 310 ] 1 RG-5 X 0 0 [ ] 0 [ ] - - - -
C6008 PHYS AHU-70 VAV-7 Y 550 [ 260 ] 2 SD-2 SF-70 R 550 [ 260 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -
C6009 LEARNERS AHU-70 VAV-9 Y 310 [ 150 ] 1 SD-2 SF-70 R 310 [ 150 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -
C6010 NP AHU-70 VAV-10 Y 260 [ 120 ] 1 SD-2 SF-70 R 260 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C6011 CHIEF AHU-70 VAV-11 Y 110 [ 52 ] 1 SD-1 SF-70 R 110 [ 52 ] 1 RG-2 X 0 0 [ ] 0 [ ] - - - -
C6012 RN AHU-70 VAV-12 Y 310 [ 150 ] 1 SD-2 SF-70 R 310 [ 150 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -
C6013 LEARNERS AHU-70 VAV-13 Y 300 [ 140 ] 1 SD-2 SF-70 R 300 [ 140 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -
C6014 PHYS AHU-70 VAV-14 Y 310 [ 150 ] 1 SD-2 SF-70 R 310 [ 150 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -
C6015 MD OFFICE AHU-70 VAV-15 Y 300 [ 140 ] 1 SD-2 SF-70 R 300 [ 140 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -
C6016 MD OFFICES AHU-70 VAV-16 Y 590 [ 280 ] 2 SD-2 SF-70 R 590 [ 280 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -
C6017 MD OFFICE AHU-70 VAV-17 Y 80 [ 38 ] 1 SD-2 SF-70 R 80 [ 38 ] 1 RG-1 X 0 0 [ ] 0 [ ] - - - -
C6018 MECH RM N/A N/A N 0 [ ] 1 SD-2 AHU-1 N/A 0 [ ] 0 0 0 [ ] 0 [ ] - - - -
C6019 MSAs AHU-70 VAV-18 Y 730 [ 340 ] 4 SD-1 SF-70 R 730 [ 340 ] 2 RG-4 X 0 0 [ ] 0 [ ] - - - -
C6020 VESTIBULE AHU-70 VAV-21 Y 100 [ 47 ] 1 SD-2 SF-70 N/A 0 [ ] 0 X + 0 [ ] 100 [ 47 ] - - - -
C6021 BUS MNGR AHU-70 VAV-23 Y 140 [ 66 ] 1 SD-1 SF-70 R 140 [ 66 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C6022 CONFERENCE AHU-70 VAV-25 Y 180 [ 85 ] 1 SD-1 SF-70 R 180 [ 85 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C6023 PRACTICE MNGR AHU-70 VAV-27 Y 110 [ 52 ] 1 SD-1 SF-70 R 110 [ 52 ] 1 RG-2 X 0 0 [ ] 0 [ ] - - - -
C6024 CHIEF AHU-70 VAV-29 Y 140 [ 66 ] 1 SD-1 SF-70 R 140 [ 66 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C6025 CHIEF AHU-70 VAV-28 Y 220 [ 100 ] 1 SD-2 SF-70 R 220 [ 100 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C6026 N CHIEF AHU-70 VAV-26 Y 190 [ 90 ] 1 SD-1 SF-70 R 190 [ 90 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C6027 N CHIEF AHU-70 VAV-24 Y 190 [ 90 ] 1 SD-1 SF-70 R 190 [ 90 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C6028 MSA SUPV AHU-70 VAV-22 Y 190 [ 90 ] 1 SD-1 SF-70 R 190 [ 90 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C6029 PSA AHU-70 VAV-20 Y 280 [ 130 ] 1 SD-2 SF-70 R 280 [ 130 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C6030 MD OFFICE AHU-70 VAV-19 Y 470 [ 220 ] 2 SD-2 SF-70 R 470 [ 220 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -
C6031 MECH RM AHU-1 VAV-61 Y 360 [ 170 ] 1 SD-2 AHU-1 E 360 [ 170 ] 1 EG-4 EF-37 X 0 0 [ ] 0 [ ] FAN POWERED VAV
C6032 MD OFFICE AHU-70 VAV-3 Y 80 [ 38 ] 1 SD-1 SF-70 E 80 [ 38 ] 1 EG-1 EF-37 X 0 0 [ ] 0 [ ] - - - -
C6-23 CORRIDOR AHU-70 VAV-4 Y 170 [ 80 ] 1 SD-1 SF-70 E 1500 [ 710 ] 2 EG-5 EF-37 X + 1330 [ 630 ] 0 [ ] - - - -
C6-24 CORRIDOR AHU-70 VAV-8 Y 195 [ 92 ] 2 SD-1 SF-70 R 145 [ 68 ] 1 RG-3 X + 0 [ ] 50 [ 24 ] - - - -
C6-25 CORRIDOR AHU-70 VAV-64 Y 100 [ 47 ] 1 SD-1 SF-70 N/A 0 [ ] 0 0 [ ] 100 [ 47 ] - - - -
C7001 LOCKERS AHU-70 VAV-60 Y 150 [ 71 ] 1 SD-1 SF-70 E 220 [ 100 ] 1 EG-3 EF-41 X - 70 [ 33 ] 0 [ ] - - - -
C7001A STAFF TLT N/A N/A N 0 [ ] 0 N/A N/A E 75 [ 35 ] 1 EG-1 EF-41 X - - 75 [ 35 ] 0 [ ] - - - -
C7003 LOCKERS AHU-70 VAV-59 Y 210 [ 99 ] 1 SD-1 SF-70 E 280 [ 130 ] 1 EG-3 EF-41 X - 70 [ 33 ] 0 [ ] - - - -
C7003A STAFF TLT N/A N/A N 0 [ ] 0 N/A N/A E 75 [ 35 ] 1 EG-1 EF-41 X - - 75 [ 35 ] 0 [ ] - - - -
C7005BREAK RM/MAIL
RMAHU-70 VAV-58 Y 620 [ 290 ] 2 SD-2 SF-70 E+R 705 [ 330 ] 2 RG-3, EG-4 EF-41 X - 85 [ 40 ] 0 [ ] - - - -
C7006 HSKP N/A N/A N 0 [ ] 0 N/A N/A E 75 [ 35 ] 1 EG-1 EF-41 X - - 75 [ 35 ] 0 [ ] - - - -
C7007 WAITING ROOM AHU-70 VAV-55, VAV-56 Y 790 [ 370 ] 3 SD-1, SD-2, SD-2 SF-70 E+R 900 [ 420 ] 2 RG-5, EG-2 EF-41 X - 110 [ 52 ] 0 [ ] - - - -
C7008 PAT TLT N/A N/A N 0 [ ] 0 N/A SF-70 E 75 [ 35 ] 1 EG-1 EF-41 X - - 75 [ 35 ] 0 [ ] - - - -
C7009 RECEPT AHU-70 VAV-57 Y 200 [ 94 ] 1 SD-1 SF-70 N/A 0 [ ] 0 X 0 0 [ ] 200 [ 94 ] - - - -
C7010 CHECK OUT AHU-70 N/A N 0 N/A N/A R 200 [ 94 ] 1 RG-3 - - - -
C7011 EXAM AHU-70 VAV-49 Y 262 [ 120 ] 1 SD-2 SF-70 R 262 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7012 EXAM AHU-70 VAV-50 Y 270 [ 130 ] 1 SD-2 SF-70 R 270 [ 130 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7013 TEAM RM AHU-70 VAV-51 Y 350 [ 170 ] 1 SD-2 SF-70 R 350 [ 170 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -
C7014 TLT RM AHU-70 VAV-51 Y 50 [ 24 ] 0 SD-1 SF-70 E 100 [ 47 ] 1 EG-13 X - - 50 [ 24 ] 0 [ ] - - - -
C7015 EXAM AHU-70 VAV-52 Y 270 [ 130 ] 1 SD-2 SF-70 R 270 [ 130 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7016 EXAM AHU-70 VAV-53 Y 280 [ 130 ] 1 SD-2 SF-70 R 280 [ 130 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7017 EXAM AHU-70 VAV-48 Y 250 [ 120 ] 1 SD-2 SF-70 R 250 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7018 TEAM RM AHU-70 VAV-47 Y 160 [ 76 ] 1 SD-1 SF-70 R 160 [ 76 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7019 EXAM AHU-70 VAV-46 Y 160 [ 76 ] 1 SD-2 SF-70 R 160 [ 76 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7020 EXAM AHU-70 VAV-45 Y 250 [ 120 ] 1 SD-2 SF-70 R 250 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7021 TEAM RM AHU-70 VAV-44 Y 250 [ 120 ] 1 SD-2 SF-70 R 250 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7022 EXAM AHU-70 VAV-43 Y 250 [ 120 ] 1 SD-2 SF-70 R 250 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7023 STOR N/A N/A N 0 [ ] 0 N/A N/A N/A 0 [ ] 0 0 [ ] 0 [ ] - - - -
C7024 ELEC N/A N/A N 0 [ ] 0 N/A N/A N/A 0 [ ] 0 - - 0 [ ] 0 [ ] - - - -
C7025 SOILED HOLDING N/A N/A N 0 [ ] 0 N/A N/A E 210 [ 99 ] 1 EG-3 EF-41 x N/A 210 [ 99 ] 0 [ ] - - - -
C7026 TEAM RM AHU-70 VAV-31 Y 210 [ 99 ] 1 SD-1 SF-70 R 210 [ 99 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7027 EXAM RM AHU-70 VAV-32 Y 140 [ 66 ] 1 SD-1 SF-70 R 140 [ 66 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7028 EXAM RM AHU-70 VAV-33 Y 140 [ 66 ] 1 SD-1 SF-70 R 140 [ 66 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7029 EXAM RM AHU-70 VAV-35 Y 140 [ 66 ] 1 SD-1 SF-70 R 140 [ 66 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7030 TEAM RM AHU-70 VAV-38 Y 260 [ 120 ] 1 SD-2 SF-70 R 260 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7031 EXAM RM AHU-70 VAV-40 Y 140 [ 66 ] 1 SD-1 SF-70 R 140 [ 66 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7032 EXAM RM AHU-70 VAV-41 Y 170 [ 80 ] 1 SD-1 SF-70 R 170 [ 80 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7033 EXAM RM AHU-70 VAV-42 Y 240 [ 110 ] 1 SD-2 SF-70 R 240 [ 110 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -
C7034 STOR N/A N/A N 0 [ ] 0 N/A N/A N/A 0 [ ] 0 0 [ ] 0 [ ] - - - -
C7035 EXAM/PROC ROOM AHU-70 VAV-39 Y 280 [ 130 ] 2 SD-1 SF-70 E+R 350 [ 170 ] 2 RG-3, EG-2 EF-41 X 0 70 [ 33 ] 0 [ ] - - - -
C7036 PAT TLT N/A N/A N 0 [ ] 0 N/A SF-70 E 75 [ 35 ] 1 EG-1 EF-41 X - - 75 [ 35 ] 0 [ ] - - - -
C7037 EXAM/PROC AHU-70 VAV-36 Y 280 [ 130 ] 1 SD-2 SF-70 E+R 350 [ 170 ] 2 RG-3, EG-2 EF-41 X 0 70 [ 33 ] 0 [ ] - - - -
C7037A PAT TLT N/A VAV-37 N 70 [ 33 ] 1 SD-1 SF-70 E 120 [ 57 ] 1 EG-2 EF-41 X - - 50 [ 24 ] 0 [ ] - - - -
C7039 CLEAN STORAGE AHU-70 VAV-34 N 200 [ 94 ] 1 SD-1 SF-70 R 120 [ 57 ] 1 RG-2 X + 0 [ ] 80 [ 38 ] - - - -
C7040 MECH RM AHU-70 VAV-65 Y 200 [ 94 ] 1 SD-1 SF-70 R 200 [ 94 ] 1 RG-3 X 0 0 [ ] 0 [ ] FAN POWERED VAV
C7-08 CORRIDOR N/A N/A N/A 0 [ ] N/A N/A N/A 0 - - - -
C7-09 CORRIDOR AHU-70 VAV-30,VAV-37 Y 300 [ 140 ] 2 SD-2 SF-70 R 250 [ 120 ] 1 RG-3 X + 0 [ ] 50 [ 24 ] - - - -
C7-10 CORRIDOR AHU-70 VAV-54 Y 190 [ 90 ] 1 SD-2 SF-70 R 140 [ 66 ] 1 RG-3 X + 0 [ ] 50 [ 24 ] - - - -
C7-11 CORRIDOR AHU-70 VAV-57 Y 100 [ 47 ] 1 SD-1 SF-70 N/A 0 [ ] 0 X + 0 [ ] 100 [ 47 ] - - - -
NOTES
1. ROOMS OR AREAS DO NOT HAVE INDIVIDUAL HUMIDITY CONTROL UNLESS NOTED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
10/05/18RESPONSIBLE CHARGE
10/05/18COVERING HVAC DESIGN
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/5
/2018 5
:57:5
4 P
M
MH-604
MECHANICAL SCHEDULE II
10/05/18 PP KGRevisions: Date:
C-6144
C6-25
C6001
C6002
C6002A
C6032
C6031
C6006
C6004C6005
C6007C6008
C6009C6010
C6011
C6012C6013
C6014C6015
C6016
C6-24
C6017
S2-6
C6030
C6029
C6019
C6028
C6021
C6027C6022
C6026
C6023
C6025
C6024
2 1/2" HWS
2 1/2" HWR
(E) 3" HWS/RRISERS
RADIANT CEILINGHEATING PANEL (TYP.)
RADIANT CEILINGHEATING PANEL (TYP)
RADIANT CEILINGHEATING PANEL (TYP)
1 1/2" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
1 1/2" HWS/R
3/4" HWS/R
1 1/2" HWS/R
3/4" HWS/R
1 1/2" HWS/R
2" HWS/R
1 1/2" HWS/R
3/4" HWS/R
1 1/2" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
RP-02
RP-03
RP-04
RP-05
RP-06
RP-07
RP-01
RP-08 RP-09
RP-10 RP-11 RP-12RP-13
RP-14
1 1/2" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
RP-15
RP-16
RP-17RP-20 RP-19RP-18RP-21RP-22
RP-23
RP-24
RP-25
RP-26
RP-27
RP-28
RP-29
RP-30
RP-31
RP-32
RP-33
RP-34
RP-35
RP-36
RP-37
RP-38
RP-39
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
VAV-1
VAV-2
VAV-3
VAV-4
VAV-5
VAV-6
VAV-7
VAV-8
VAV-9
VAV-10
VAV-12
VAV-13
VAV-14
VAV-15
VAV-16
VAV-17
VAV-18
CAV-21
VAV-23
VAV-27
VAV-26
VAV-24
VAV-22VAV-20
VAV-19
VAV-11
VAV-25
VAV-29VAV-28
3
1
TYP.
TYP.
2
TYP.
CAV-61
4
4
4
VAV-62
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
TT
T
T
T
T
T
T
T
T
TT
T T
T
2
MP-106
VAV-64
T
3/4" HWS/R
3/4" HWS/R
Level 6_770-5.2558' - 5 1/4"
Level 7_781-5.2569' - 5 1/4"
Level 7_781-5.2569' - 5 1/4"
2-1/2" HWS/R
4" HWR4" HWS
EXISTING HWREXISTING HWS
A. EXISTING WORK TO REMAIN AS INDICATED WITH LIGHT LINEWEIGHT.
B. NEW WORK IS INDICATED WITH HEAVY LINE WEIGHT.
C. REMOVE ALL HANGERS, SUPPORTS, TUBING, AND CONTROLDEVICES ASSOCIATED WITH EQUIPMENT TO BE REMOVED.
D. COORDINATE ALL SYSTEM OUTAGES WITH OWNER.
E. ASBESTOS ON EXISTING PIPING, DUCT, AND EQUIPMENTSHALL BE REMOVED BACK TO MAIN BY ABATEMENTCONTRACTOR AND NEEDS TO BE RE-INSULATED BY THEMECHANICAL CONTRACTOR. WORK TO BE COORDINATEDWITH ABATEMENT CONTRACTOR.
F. LOCATE BALANCE DAMPERS SO THEY CAN BE ACCESSEDTHROUGH CEILING TILE OR WITH REMOTE BALANCE DAMPERADJUSTMENT DEVICE.
G. INSTALL ALL EQUIPMENT AND ACCESSORIES IN ACCORDANCEWITH MANUFACTURERS’ RECOMMENDATIONS, CONTRACTDOCUMENTS, AND APPLICABLE CODES AND REGULATIONS.
H. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORKWITH OTHER DISCIPLINES: ARCHITECTURAL, PLUMBING,ELECTRICAL, ETC., SHOWN ON OTHER CONTRACTRDOCUMENTS.
I. ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICALEQUIPMENT AND PIPING INSULATION IS APPLIED.
J. LOCATE ALL TEMPERATURE, PRESSURE, AND FLOWMEASURING DEVICES IN ACCESSIBLE LOCATIONS WITHSTRAIGHT SECTION OF PIPE OR DUCT UP AND DOWNSTREAMAS RECOMMENDED BY THE MANUFACTURER FOR GOODPERFORMANCE.
K. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS ORREQUIRED BY THE SPECIFICATIONS NOT DEFINITELY FIXED BYDIMENSIONS ARE APPROXIMATE ONLY. THE EXACT LOCATIONSNECESSARY TO SECURE THE BEST RESULTS MUST BEDETERMINED BY THE PROJECT SITE CONDITIONS AND SHALLHAVE THE APPROVAL OF THE ENGINEER BEFORE BEINGINSTALLED. DO NOT SCALE DRAWINGS.
L. PROVIDE AT LEAST 14 DAYS ADVANCE NOTICE TO THE COR FORANY UTILITY SHUT DOWNS.
M. LOCATE BALANCE VALVES SO THEY CAN BE ACCESSEDTHROUGH THE CEILING TILE OR PROVIDE ACCESS PANEL(S).
N. INSTALL EQUIPMENT WITH MINIMUM ACCESS CLEARANCE ASRECOMMENDED BY CODE AND MANUFACTURERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
10/05/18RESPONSIBLE CHARGE
10/05/18COVERING HVAC DESIGN
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/5
/2018 5
:57:5
9 P
M
MP-106
6TH FLOOR PIPING NEW WORK
10/05/18 PP KG
1/8" = 1'-0"MP-106
1 6TH FLOOR PIPING - NEW WORK
1. PROVIDE NEW HOT WATER HEATING DISTRIBUTIONPIPING, VALVES, INSULATION, SPECIALTIES & HANGERS,ROUTED AS HIGH AS POSSIBLE. COORDINATE CLOSELYWITH DUCTWORK.
2. LOCATE RADIANT CEILING PANELS CLOSE TO EXTERIORSURFACES & CENTERED WITH REFERENCE TO WINDOWS,TO THE EXTENT POSSIBLE. COORDINATE CLOSELY WITHCEILING & LIGHTING LAYOUT.
3. WHERE A ZONE HAS MORE THAN ONE RADIANT PANEL,PANEL CONTROL VALVES SHALL OPERATE TO PARALLELFROM SINGLE SPACE CONTROL POINT.
4. PROVIDE 3-WAY CONTROL VALVE.
DRAWING NOTES:
GENERAL NOTES:
6TH FLOOR ROOM SCHEDULE
ROOM NO ROOM NAMEC6-23 CORRIDOR
C6-24 CORRIDOR
C6-25 CORRIDOR
C6001 LEARNERS
C6002 MD OFFICES
C6002A CHIEF
C6004 TLT RM
C6005 TLT RM
C6006 BREAK RM
C6007 CONF RM
C6008 PHYS
C6009 LEARNERS
C6010 NP
C6011 CHIEF
C6012 RN
C6013 LEARNERS
C6014 PHYS
C6015 MD OFFICE
C6016 MD OFFICES
C6017 MD OFFICE
C6018 MECH RM
C6019 MSA'S
C6020 VESTIBULE
C6021 BUS MNGR
C6022 CONFERENCE
C6023 PRACTICE MNGR
C6024 CHIEF
C6025 CHIEF
C6026 N CHIEF
C6027 N CHIEF
C6028 MSA SUPV
C6029 PSA
C6030 MD OFFICE
C6031 MECH. ROOM
C6032 MD OFFICE
1/4" = 1'-0"MP-106
2 ENLAGERED MECHANICAL ROOM
Revisions: Date:
2-1/2" HW
2-1/2" HW
NEW 3" HW/RRISERS
RADIANT CEILINGHEATING PANEL (TYP)
MP-107
2
3/4" HWS/R
RP-57
RP-58
RP-56
RP-55
RP-54
RP-53
RP-52
RP-51
RP-50
RP-81 RP-80 RP-79 RP-78 RP-77 RP-76
RP-75
RP-74
RP-73
RP-72RP-71RP-70RP-69RP-68
RP-46
RP-45
RP-44
RP-43
RP-42
RP-40
RP-47
RP-48
RP-49
RP-67
RP-66
RP-65
RP-64
RP-62
RP-61
RP-60
RP-59
VAV-32
VAV-33
VAV-38
VAV-40
VAV-41VAV-42
VAV-39
VAV-37
VAV-36
VAV-31
VAV-30
VAV-55
VAV-57
VAV-56
VAV-49 VAV-50VAV-51
CAV-54
VAV-52
VAV-53
VAV-44 VAV-45 VAV-46 VAV-47VAV-48VAV-43
VAV-58
VAV-60VAV-59
C7011 C7012
C7013
C7014 C7015
C7016
C7017
C7019 C7018C7021 C7020C7022
C7-11
C7031
C7032
C7033
C7034
C7035
C7036
C7037
C7037A
C7039
C7-9
S2-7
C7040
C7007
C7009
C-7178
C7-8
C7001A
C7001
C7003
C7003A
C7005
C7008
C7006
C-7077C-7079
C-7122
C-7123
C-7124
C-7138
C-7139
C7-25
C-7075
C-7059
C-7076
C7-7
S1-7
C7025
C7010
C-7081
48
C7026
C7027
C7028
C7029
C7030
C7023
C7024
C7-10
1 1/2" HWS/R
3/4" HWS/R
RADIANT CEILINGHEATING PANEL (TYP)
3/4'' HWS/R1 1/2'' HWS/R
3/4'' HWS/R
3/4'' HWS/R
3/4'' HWS/R
3/4'' HWS/R 3/4'' HWS/R 3/4'' HWS/R 3/4'' HWS/R
RADIANT CEILINGHEATING PANEL (TYP)
3/4'' HWS/R3/4'' HWS/R
1 1/2'' HWS/R
1 1/2'' HWS/R
1 1/2'' HWS/R
3/4'' HWS/R
2'' HWS/R
2' HWS/R
3/4'' HWS/R
3/4'' HWS/R
3/4'' HWS/R
3/4'' HWS/R
3/4'' HWS/R
3/4'' HWS/R
3/4'' HWS/R
3/4'' HWS/R
3/4'' HWS/R
1 1/2'' HWS/R
VAV-34
RP-63
RP-41
VAV-35
3
2
1
TYP.
TYP.
TYP.
6
6
6
T
T
T
T
T
T
T T T T T
T
TTT
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
MP-107
3
4
MP-107
3/4'' HWS/R
3/4'' HWS/R
3/4'' HWS/R
CAV-65
NEW 3" HW/RRISERS
RADIANT CEILINGHEATING PANEL (TYP)
1 1/2" HWS/R
RP-70 RP-72
RP-73
RP-75
RP-76RP-79
VAV-51 VAV-53
VAV-45
4
4
4
44
4
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R3/4" HWS/R
2-1/2" HWS/R
2-1/2" HWS/R
C7040
4
MP-107
EXISTINGCHWS/R RISER
AHU-70
NEW 2-1/2" CHWS/R
Level 7a69'-5 1/4"
Level 7_781-5.2569' - 5 1/4"
Level 8_793-4.2581' - 4 1/4"
Level 7_781-5.2569' - 5 1/4"
Level 8_793-4.2581' - 4 1/4"
Level 7_781-5.2569' - 5 1/4"
2-1/2" HWS/R
NEW 4" HWS/RA. EXISTING WORK TO REMAIN AS INDICATED WITH LIGHT LINE
WEIGHT.
B. NEW WORK IS INDICATED WITH HEAVY LINE WEIGHT.
C. REMOVE ALL HANGERS, SUPPORTS, TUBING, AND CONTROLDEVICES ASSOCIATED WITH EQUIPMENT TO BE REMOVED.
D. COORDINATE ALL SYSTEM OUTAGES WITH OWNER.
E. ASBESTOS ON EXISTING PIPING, DUCT, AND EQUIPMENTSHALL BE REMOVED BACK TO MAIN BY ABATEMENTCONTRACTOR AND NEEDS TO BE RE-INSULATED BY THEMECHANICAL CONTRACTOR. WORK TO BE COORDINATEDWITH ABATEMENT CONTRACTOR.
F. LOCATE BALANCE DAMPERS SO THEY CAN BE ACCESSEDTHROUGH CEILING TILE OR WITH REMOTE BALANCE DAMPERADJUSTMENT DEVICE.
G. INSTALL ALL EQUIPMENT AND ACCESSORIES IN ACCORDANCEWITH MANUFACTURERS’ RECOMMENDATIONS, CONTRACTDOCUMENTS, AND APPLICABLE CODES AND REGULATIONS.
H. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORKWITH OTHER DISCIPLINES: ARCHITECTURAL, PLUMBING,ELECTRICAL, ETC., SHOWN ON OTHER CONTRACTRDOCUMENTS.
I. ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICALEQUIPMENT AND PIPING INSULATION IS APPLIED.
J. LOCATE ALL TEMPERATURE, PRESSURE, AND FLOWMEASURING DEVICES IN ACCESSIBLE LOCATIONS WITHSTRAIGHT SECTION OF PIPE OR DUCT UP AND DOWNSTREAMAS RECOMMENDED BY THE MANUFACTURER FOR GOODPERFORMANCE.
K. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS ORREQUIRED BY THE SPECIFICATIONS NOT DEFINITELY FIXED BYDIMENSIONS ARE APPROXIMATE ONLY. THE EXACT LOCATIONSNECESSARY TO SECURE THE BEST RESULTS MUST BEDETERMINED BY THE PROJECT SITE CONDITIONS AND SHALLHAVE THE APPROVAL OF THE ENGINEER BEFORE BEINGINSTALLED. DO NOT SCALE DRAWINGS.
L. PROVIDE AT LEAST 14 DAYS ADVANCE NOTICE TO THE COR FORANY UTILITY SHUT DOWNS.
M. LOCATE BALANCE VALVES SO THEY CAN BE ACCESSEDTHROUGH THE CEILING TILE OR PROVIDE ACCESS PANEL(S).
N. INSTALL EQUIPMENT WITH MINIMUM ACCESS CLEARANCE ASRECOMMENDED BY CODE AND MANUFACTURERS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
10/05/18RESPONSIBLE CHARGE
10/05/18COVERING HVAC DESIGN
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/5
/2018 5
:58:0
4 P
M
MP-107
7TH FLOOR PIPING NEW WORK
10/05/18 PP KG
1/8" = 1'-0"MP-107
1 7TH FLOOR PIPING - NEW WORK 1/8" = 1'-0"MP-107
2 7TH FLOOR PIPING - NEW WORK - ALTERNATE
1. PROVIDE NEW HOT WATER HEATING DISTRIBUTIONPIPING, VALVES, INSULATION, SPECIALTIES & HANGERS,ROUTED AS HIGH AS POSSIBLE. COORDINATE CLOSELYWITH DUCTWORK.
2. LOCATE RADIANT CEILING PANELS CLOSE TO EXTERIORSURFACES & CENTERED WITH REFERENCE TO WINDOWS,TO THE EXTENT POSSIBLE. COORDINATE CLOSELY WITHCEILING & LIGHTING LAYOUT.
3. WHERE A ZONE HAS MORE THAN ONE RADIANT PANEL,PANEL CONTROL VALVES SHALL OPERATE TO PARALLELFROM SINGLE SPACE CONTROL POINT.
4. ALTERNATE BID: PROVIDE HOT WATER SUPPLY & RETURNPIPING, CONTROLS, VALVES, INSULATION, SPECIALTIESHANGERS & CONNECT TO AIR TERMINAL REHEAT COIL.PROVIDE VALVE & CAPPED EXTENSIONS FOR FUTURERADIANT PANEL.
5. ALTERNATE BID: PROVIDE HOT WATER SUPPLY & RETURNVALVED & CAPPED NEAR LOCATION OF AIR TERMINAL FORFUTURE AIR TERMINAL, REHEAT COIL & RADIANT PANEL.
6. PROVIDE 3-WAY CONTROL VALVE.
DRAWING NOTES:
GENERAL NOTES:
7TH FLOOR ROOM SCHEDULE
ROOM NO ROOM NAMEC7-8 CORRIDOR
C7-9 CORRIDOR
C7-10 CORRIDOR
C7-11 CORRIDOR
C7001 LOCKERS
C7001A STAFF TLT
C7003 LOCKERS
C7003A STAFF TLT
C7005 BREAK RM /MAIL RM
C7006 HSKP
C7007 WAITING ROOM
C7008 PAT TLT
C7009 RECEPT
C7010 CHECK OUT
C7011 EXAM
C7012 EXAM
C7013 TYPICAL TEAM RM
C7014 TLT RM
C7015 EXAM
C7016 EXAM
C7017 EXAM
C7018 TEAM RM
C7019 EXAM
C7020 EXAM
C7021 TEAM RM
C7022 EXAM
C7023 STOR
C7024 ELEC
C7025 SOILED HOLDING
C7026 TEAM RM
C7027 EXAM RM
C7028 TYPICAL EXAM RM
C7028 Room
C7029 EXAM RM
C7029 Room
C7030 TEAM RM
C7031 EXAM RM
C7032 EXAM RM
C7033 EXAM RM
C7034 STOR
C7035 EXAM/PROC ROOM
C7036 PAT TLT
C7037 EXAM/PROC
C7037A PAT TLT
C7039 CLEAN STORAGE
C7040 MECH RM
1/4" = 1'-0"MP-107
3 7TH FLOOR PIPING - NEW WORK MECH ROOM
1/4" = 1'-0"MP-107
4 ENLARGED MECHANICAL ROOM
Revisions: Date:
MP-401
5
MP-401
6
1
2
5
6
2
1
6
MP-401
3
MP-401
4
1
2
5
6
2
1
6
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
10/05/18RESPONSIBLE CHARGE
10/05/18COVERING HVAC DESIGN
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/5
/2018 5
:58:0
8 P
M
MP-401
HWS PIPING BASEMENT AND 1STFLOOR PLAN
10/05/18 PP KG
1/16" = 1'-0"MP-401
2 1ST FLOOR HWS PLAN
1/8" = 1'-0"MP-401
5 1ST FLOOR HWS ENLARGED PLAN EAST
1/8" = 1'-0"MP-401
6 1ST FLOOR HWS ENLARGED PLAN WEST
1. EXISTING HWS RISER
2. EXISTING HWR RISER
3. EXISTING ACOUSTICAL TILE CEILING - REMOVE ANDREPLACE AS REQUIRED FOR WORK ABOVE.
4. EXISTING GYPSUM BOARD CEILING - REMOVE ANDREPLACE AS REQUIRED FOR WORK ABOVE.
5. EXISTING GYPSUM BOARD CEILING - PROVIDE ACCESSPANEL FOR ACCESS AS REQUIRED FOR ACCESS TOVALVES ABOVE.
6. REPLACE EXISTING HWS VALVES WITH NEWCOMBINATION BALANCING VALVE-ISOLATION VALVE WITHMEMORY STEP. REPLACE EXISTING HWR VALVE WITHNEW ISOLATION VALVE.
DRAWING NOTES:
1/16" = 1'-0"MP-401
1 BASEMENT HWS PLAN
1/8" = 1'-0"MP-401
3 BASEMENT HWS ENLARGED PLAN EAST
1/8" = 1'-0"MP-401
4 BASEMENT HWS ENLARGED PLAN WEST
Revisions: Date:
MP-402
3
MP-402
4
MP-402
6
2
1
6
STAFF WORK ROOM
1
2
3
6
1
2
4
6
5
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
10/05/18RESPONSIBLE CHARGE
10/05/18COVERING HVAC DESIGN
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/5
/2018 5
:58:1
2 P
M
MP-402
HWS PIPING 2ND AND 3RD FLOOR
10/05/18 PP KG
1/16" = 1'-0"MP-402
1 2ND FLOOR HWS PLAN
1/16" = 1'-0"MP-402
2 3RD FLOOR HWS PLAN
1/8" = 1'-0"MP-402
3 2ND FLOOR HWS ENLARGED PLAN WEST
1/8" = 1'-0"MP-402
4 2ND FLOOR HWS PLAN ENLARGED PLAN EAST
1/8" = 1'-0"MP-402
6 3RD FLOOR HWS ENLARGED PLAN EAST
1. EXISTING HWS RISER
2. EXISTING HWR RISER
3. EXISTING ACOUSTICAL TILE CEILING - REMOVE AND REPLACEAS REQUIRED FOR WORK ABOVE.
4. EXISTING GYPSUM BOARD CEILING - REMOVE AND REPLACE ASREQUIRED FOR WORK ABOVE.
5. EXISTING GYPSUM BOARD CEILING - PROVIDE ACCESS PANELFOR ACCESS PANEL AS REQUIRED FOR ACCESS VALVESABOVE.
6. REPLACE EXISTING HWS VALVES WITH NEW COMBINATIONBALANCING VALVE-ISOLATION VALVE WITH MEMORY STEP.REPLACE EXISTING HWR VALVE WITH NEW ISOLATION VALVE.
DRAWING NOTES:
Revisions: Date:
MP-403
3MP-403
6
2
1
6
2
1
6
5
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
10/05/18RESPONSIBLE CHARGE
10/05/18COVERING HVAC DESIGN
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/5
/2018 5
:58:1
5 P
M
MP-403
HWS PIPNG 4TH AND 5TH FLOOR
10/05/18 PP KG
1/16" = 1'-0"MP-403
1 4TH FLOOR HWS PLAN
1/16" = 1'-0"MP-403
2 5TH FLOOR HWS PLAN
1/8" = 1'-0"MP-403
3 4TH FLOOR HWS PLAN ENLARGED PLAN WEST
1/8" = 1'-0"MP-403
6 5TH FLOOR HWS ENLARGED PLAN WEST
1. EXISTING HWS RISER
2. EXISTING HWR RISER
3. EXISTING ACOUSTICAL TILE CEILING - REMOVE AND REPLACEAS REQUIRED FOR WORK ABOVE.
4. EXISTING GYPSUM BOARD CEILING - REMOVE AND REPLACEAS REQUIRED FOR WORK ABOVE.
5. EXISTING GYPSUM BOARD CEILING - PROVIDE ACCESS PANELFOR ACCESS PANEL AS REQUIRED FOR ACCESS TO VALVESABOVE.
6. REPLACE EXISTING HWS VALVES WITH NEW COMBINATIONBALANCING VALVE-ISOLATION VALVE WITH MEMORY STEP.REPLACE EXISTING HWR VALVE WITH NEW ISOLATION VALVE.
DRAWING NOTES:
Revisions: Date:
MP-404
2
MP-404
3
11
10
9
3
4
3
21'-5 3/16"
CHASE 114
14
14
12
13
14
8
6
TYP.5
65
65
MP-404
5
MP-404
6
2
1
8
11
10
9
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
10/05/18RESPONSIBLE CHARGE
10/05/18COVERING HVAC DESIGN
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/5
/2018 5
:58:1
9 P
M
MP-404
HWS PIPING 8TH AND 9TH FLOOR
10/05/18 PP KG
1/16" = 1'-0"MP-404
1 9TH FLOOR HWS PLAN
1/8" = 1'-0"MP-404
2 9TH FLOOR HSW ENLARGED PLAN WEST
1/8" = 1'-0"MP-404
3 9TH FLOOR HWS ENLARGED PLAN EAST 1/16" = 1'-0"MP-404
4 8TH FLOOR HWS PLAN
1/8" = 1'-0"MP-404
5 8TH FLOOR HWS ENLARGED PLAN WEST
1. NEW HWS RISER
2. NEW HWR RISER
3. EXISTING ACOUSTICAL TILE CEILING - REMOVE ANDREPLACE AS REQUIRED FOR WORK ABOVE.
4. EXISTING GYPSUM BOARD CEILING AND EXISTING DIFFUSERSTO BE DEMOLISHED AND REPLACED WITH NEW ACOUSTICALTILE CEILING AND SQUARE DIFFUSERS.
5. PRIOR TO DEMOLITION, CONTRACTOR SHALL VERIFY ALLSOURCES TO AIR DEVICES AND PERFORM PRE-BALANCE.RECORD DATA PER EACH AIR DEVICE IN BALANCE REPORT.
6. 12 INCH BY 12 INCH GRILLES ARE ASSUMED TO BE OUTSIDEAIR SUPPLY AND/OR EXHAUST AND MAY BE REUSED IN NEWGRID TYPE CEILING WHERE POSSIBLE. NEW DIFFUSERSSHALL BE SQUARE HIGH PERFORMANCE CONE TYPE.CONTRACTOR SHALL SELECT DIFFUSER WITH NECK SIZECOMPATABLE WITH EXISTING DUCT. BALANCE NEWDIFFUSERS TO MATCH EXISTING AIR FLOWS DOCUMENTED INPRE-BALANCE REPORT.
7. EXISTING GYPSUM BOARD CEILING - PROVIDE ACCESSPANEL FOR ACCESS PANEL AS REQUIRED FOR ACCESS TOVALVES ABOVE.
8. PROVIDE NEW BRANCH PIPING FROM NEW HWS & HWRRISER TO EXISTING HWS/R DISTRIBUTION TO SERVE THISFLOOR, CONNECTION TO EXISTING WHOLE SHOWN.PROVIDE NEW COMBINATION BALANCING VALVE-ISOLATION VALVE WITH MEMORY STOP AT CONNECTIONPOINT FOR SUPPLY & NEW ISOLATION VALVE ATCONNECTION ON RETURN.
9. REPLACE EXISTING HWS VALVES WITH NEWCOMBINATION BALANCING VALVE-ISOLATION VALVE WITHMEMORY STOP. REPLACE EXISTING HWR VALVE WITH NEWISOLATION VALVE.
10. EXISTING HWS RISER
11 EXISTING HWR RISER
12. EXSITING HWR RISER TO 10TH FLOOR MECHANICALROOM
13. EXISTING PIPING TO WEST CHASE TO REMAIN
14. REMOVE AND REPLACE EXISTING 3" HWS & HWR PIPING IN9TH FLOOR CEILING. RISER WITH 4" PIPING AS SHOWNEXTENDED INTO CHASE 1.
DRAWING NOTES:
1/8" = 1'-0"MP-404
6 8TH FLOOR HWS ENLARGED PLAN EAST
Revisions: Date:
3" HWR
532
4
1
PUMPEDCONDENSATE
L. P. STEAM
4" HWS
4" HWS
4" HWR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
10/05/18RESPONSIBLE CHARGE
10/05/18COVERING HVAC DESIGN
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/5
/2018 5
:58:2
0 P
M
MP-405
HWS/HWR PIPING 10TH FLOORPENTHOUSE
10/05/18 PP KG
1/4" = 1'-0"MP-405
1 HWS PENTHOUSE PLAN
1. EXISTING HEATING HWS & HWR PIPING DOWN TOCORRIDOR ON 9TH FLOOR. CONTINUED ON SHEET MP-404.
2. EXISTING HEATING EQUIPMENT RACK.
3. EXISTING STEAM TO HOT WATER HEAT EXCHANGER.
4. REPLACE EXISTING AIR SEPARATOR WITH NEW SPIROTHERMOR EQUAL AIR/DIRT SEPARATOR WITH 3" CONNECTIONS.PROVIDE NEW 3" LINE WHERE SHOWN.
5. REPLACE EXISTING END SUCTION PUMPS. VALVES,STRAINERS, EXPANSION JOINTS ALSO TO BE REPLACED.REFER TO DETAILS & SCHEDULE. SHEET MH-601.
DRAWING NOTES:
Revisions: Date:
MP-406
4
C-6114
C-6129
C-6117
C-6142
84
C-6143
C-6140
C-6131
C-6132C-6133
C-6134
C-6139
C-6144
C-6128
C-6127
C-6141
MP-406
3
49
C-7176
C-7174
C-7173
C-7171
C-7177
C-7178
C-7139
C7-25
C-7138
C-7140
C7-8
C-7139
2
1
6
2
1
6
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
10/05/18RESPONSIBLE CHARGE
10/05/18COVERING HVAC DESIGN
C:\U
sers
\kyle
g\D
ocum
ents
\Revit L
ocal F
iles\India
napolis
_M
echanic
al_
kyle
.guggenheim
.rvt
10/5
/2018 5
:58:2
6 P
M
MP-406
HWS PIPING 6TH AND 7TH FLOOR
10/05/18 PP KG
1/16" = 1'-0"MP-406
1 6TH FLOOR HWS PLAN
1/16" = 1'-0"MP-406
2 7TH FLOOR HWS PLAN
1/8" = 1'-0"MP-406
3 7TH FLOOR HWS ENLARGED PLAN WEST
1/8" = 1'-0"MP-406
4 6TH FLOOR HWS ENLARGED PLAN WEST
1. EXISTING HWS RISER
2. EXISTING HWR RISER
3. EXISTING ACOUSTICAL TILE CEILING - REMOVE ANDREPLACE AS REQURIED FOR WORK ABOVE.
4. EXISTING GYPSUM BOARD CEILING - REMOVE ANDREPLACE REQUIRED FOR WORK ABOVE.
5. EXISTING GYPSUM BOARD CEILING - PROVIDE ACCESSPANEL FOR ACCESS PANEL AS REQUIRED FOR ACCESSTO PIPING ABOVE.
6. REPLACE EXISTING HWS VALVES WITH NEWCOMBINATION BALANCING VALVE-ISOLATION VALVE WITHMEMORY STEP. REPLACE EXISTING HWR VALVE WITHNEW ISOLATION VALVE.
DRAWING NOTES:
Revisions: Date:
DRYWALL CEILINGCROSS TEE, TYP.
HANGER WIRE AND MOUNTINGCHANNEL ATTACHED TO STRUCTUREREFER TO SPECIFICATION SECTION26 51 00
GYPSUMBOARD
DRYWALL CEILINGCROSS TEE, TYP.
CEILING MAINBEAM.
GENERAL NOTE:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTINGINSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.
WIRE TIE THROUGHMOUNTING CHANNEL& CROSS BEAM, TYP.
LOCKING SQUAREWASHER & NUT
JUNCTION BOX
6.35mm (1/4") SCREW
INTEGRAL GALVANIZED LIPPEDSTEEL MOUNTING CHANNEL
FIXTURE WHIP FROM JUNCTION BOX(1829mm (6') LONG MAX)
CEILING HANGER WIRE
GENERAL NOTE:
1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTINGINSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.
DRYWALL BORDER
LUMINAIRE.REFER TOSCHEDULE
CEILING CROSS BEAM
GYPSUM BOARD
CEILING CROSS BEAM
LUMINAIRE MANUFACTURER'SMOUNTING HARDWAREREFER TO SPECIFICATIONSECTION 26 51 00
LUMINAIRE.REFER TOSCHEDULE
GYPSUM BOARD (TYP)
CEILING MAIN BEAM
FIXTURE WHIP FROMJUNCTION BOX(1829mm (6') LONGMAX.)
3 TWIST MINIMUM(TYP)
LUMINAIRESUSPENSION WIRESREFER TOSPECIFICATIONSECTION 26 51 00
X
BASED ON MANUFACTURERS RECOMMENDATIONS
JUNCTION BOX ("F" INDICATES FLOOR MOUNTED)
600V 30A 3P, NON-FUSED DISCONNECT, UNLESS OTHERWISE NOTED.
FUSED DISCONNECT, SIZE FUSES FOR EQUIPMENT
SURFACE MOUNTED PANELBOARD OR AUTOMATIC TRANSFER
SWITCH AS INDICATED.
MOTOR.
J
POWER
a
LIGHTING
LVDRECESSED MOUNTED PANELBOARD
JUNCTION BOX WALL MOUNTED 48" AFF.J
A 1' x 4' FIXTURE. UPPERCASE LETTER INDICATES TYPEPER THE FIXTURE SCHEDULE. LOWERCASE LETTERINDICATES SWITCH. HATCH INDICATES FIXTURE IS ONEMERGENCY CIRCUIT
D
OCD
A
A
AA
2' x 4' FIXTURE. UPPERCASE LETTER INDICATESTYPE PER THE FIXTURE SCHEDULE. HATCHINDICATES FIXTURE IS ON EMERGENCY CIRCUIT
WALL MOUNTED LINEAR FIXTURE. UPPERCASELETTER INDICATESTYPE PER THE FIXTURE SCHEDULE. LOWERCASE LETTER INDICATESSWITCH.
A
WALL MOUNTED SCONCE. UPPERCASE LETTER INDICATES TYPE PERFIXTURE SCHEDULE. LOWERCASE LETTER INDICATES SWITCH.
EXIT SIGN WITH DIRECTIONAL ARROWS AS INDICATED
RECESSED FIXTURE, DOWNLIGHTUPPERCASE LETTER INDICATES TYPE PER FIXTURE SCHEDULE.LOWERCASE LETTER INDICATES SWITCH. "E" INDICATESBATTERY BACK-UP
A
WALL MOUNTED DIMMER SWITCH. PROVIDE 0-10V CONTROLWIRING, DAISYCHAINED TO EACH FIXTURE DRIVER TO DIM ALLLIGHTING WITHIN ROOM. EMERGENCY LIGHTING WITHIN ROOMSHALL MAINTAIN 100% LUMINOUS OUTPUT UPON LOSS OFPOWER. SET DIMMING CONTROLS TO PRESETS OF "100%","50%", "20%" AND "OFF".
WALL MOUNTED OCCUPANCY DIMMER SWITCH. PROVIDE 0-10VCONTROL WIRING, DAISYCHAINED TO EACH FIXTURE DRIVERTO DIM ALL LIGHTING WITHIN ROOM. EMERGENCY LIGHTINGWITHIN ROOM SHALL MAINTAIN 100% LUMINOUS OUTPUT UPONLOSS OF POWER.
WALL MOUNTED LOW VOLTAGE DIMMER SWITCH. PROVIDE0-10V CONTROL WIRING, DAISYCHAINED TO EACH FIXTUREDRIVER TO DIM ALL LIGHTING WITHIN ROOM. EMERGENCYLIGHTING WITHIN ROOM SHALL MAINTAIN 100% LUMINOUSOUTPUT UPON LOSS OF POWER.
WALL MOUNTED OCCUPANCY SENSOR
CEILING MOUNTED OCCUPANCY SENSOR. DUALTECHNOLOGY PIR/ULTRASONIC 360 DEGREE AT 10'.PROVIDE ADDITIONAL POWER-PACK AS REQUIRED. ALLLIGHTING WITHIN ROOM TO BE SWITCHED UPONOCCUPANCY EXCEPT EMERGENCY LIGHTING WHICH ISLEFT AT 100% OUTPUT, CONSTANTLY.
20 AMP, 125 VOLT TOGGLE SWITCH MOUNTED 42" AFF.a - CONTROLS LIGHTS WITH "a" DESIGNATION
OC COMBINATION MOTOR STARTER WITH MOTOR CIRCUIT PROTECTORSAND OVERLOADS SIZED FOR NAMEPLATE DATA
MANUAL MOTOR STARTER WITH OVERLOADS SIZED PERNAMEPLATE DATA
PUSHBUTTON
OC
NEMA 5-20R DUPLEX RECEPTACLE.DESIGNATIONS:WP = WEATHER PROOFGFI = 30mA GROUND FAULT PROTECTEDC = RECESSED CLOCK OUTLETE= FED FROM CRITICAL POWER SOURCE
NEMA 5-20R QUADRUPLEX RECEPTACLE.DESIGNATIONS:WP = WEATHER PROOFGFI = 30mA GROUND FAULT PROTECTEDC = RECESSED CLOCK OUTLETE= FED FROM CRITICAL POWER SOURCE
NEMA 5-20R QUADRUPLEX RECEPTACLE IN FLUSH FLOOR BOX
XAA
2' x 2' FIXTURE. UPPERCASE LETTER INDICATESTYPE PER THE FIXTURE SCHEDULE. LOWERCASELETTER INDICATES SWITCH. HATCH INDICATESFIXTURE IS ON EMERGENCY CIRCUIT
a a
a a
a a
a
a
a
DEVICE MOUNTING HEIGHTSSWITCHES 46" MOUNTING HEIGHT UNLESS OTHERWISE NOTED.
RECEPTACLES UNLESS OTHERWISE NOTED,18" MOUNTING HEIGHT46" OVER COUNTERS
TEL/DATA UNLESS OTHERWISE NOTED,18" MOUNTING HEIGHT46" OVER COUNTERS
X
NEMA 5-20R QUADRUPLEX RECEPTACLE, 46" MOUNTINGHEIGHT UNLESS NOTED OTHERWISE.DESIGNATIONS:WP = WEATHER PROOFGFI = 30mA GROUND FAULT PROTECTEDC = RECESSED CLOCK OUTLETE= FED FROM CRITICAL POWER SOURCE
XNEMA 5-20R DUPLEX RECEPTACLE. 46" MOUNTINGHEIGHT UNLESS NOTED OTHERWISE.DESIGNATIONS:WP = WEATHER PROOFGFI = 30mA GROUND FAULT PROTECTEDC = RECESSED CLOCK OUTLETE= FED FROM CRITICAL POWER SOURCE
EQUIPMENT CONNECTION
WIRINGEXPOSED
CONCEALED
GROUNDING
DOWN CONDUCTOR CONNECTION TO GROUND
ABBREVIATIONS
A AMPERE
AC ABOVE COUNTER, 42"AFF UNLESS OTHERWISE INDICATED
ADA AMERICANS WITH DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
AL ALUMINUM
1/C ONE CONDUCTOR
C CONDUIT
CB CIRCUIT BREAKER
CKT CIRCUIT
CU COPPER
EF EXHAUST FAN
EMT ELECTRICAL METALLIC TUBING
EWC ELECTRIC WATER COOLER
FACP FIRE ALARM CONTROL PANEL
FM FREQUENCY MODULATION
GFI GROUND FAULT CIRCUIT INTERRUPTER
GFP GROUND FAULT PROTECTIONHACR HEATING AIR CONDITIONING REFRIGERATION
HP HORSEPOWER
HPS HIGH PRESSURE SODIUM
HT HEIGHT
HZ HERTZ
IDS INTRUSION DETECTION SYSTEM
J JUNCTION BOX
KWH KILOWATT HOUR
LED LIGHT EMITTING DIODE
MCB MOLDED CASE CIRCUIT BREAKER
MH METAL HALIDE
MLO MAIN LUGS ONLY
MTD MOUNTED
NEC NATIONAL ELECTRICAL CODE
NF NON FUSED
NO. NUMBER
OS OCCUPANCY SENSOR
PH PHASE
PIR PASSIVE INFRARED
RGS RIGID GALVANIZED STEEL
SM SINGLE MODE
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
SPD SURGE PROTECTIVE DEVICE
UNO UNLESS NOTED OTHERWISE
V VOLT
VA VOLTAMPERE
VVD VARIABLE VOLUME DAMPER
W WATTS
WP WATER PROOF
XFMR TRANSFORMER
FV FLUSH VALVE
FV FLUSH VALVE
H
LUMINAIRE(S)
LOW VOLTAGEON/OFF/DIMMINGWALL STATION
ADDITIONAL LV ON/OFFWALL STATION AS REQUIREDFOR MULTIPOINT CONTROL
LINE VOLTAGE
LV
PP
OCCUPANCYSENSOR
OCCUPANCYSENSOR
(AS REQUIRED)
LV
POWER PACK/RELAY
NETWORK BRIDGE
1
2
LV - LOW VOLTAGE CABLE. SEE MANUFACTURER FOR EXACT CABLE REQUIREMENTS.THIS DETAIL IS A GENERAL SCHEMATIC AND DOES NOT CONTAIN EXACT INFORMATION PER MANUFACTURER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:10:2
9 P
M
EI-001
ELECTRICAL GENERALINFORMATION
10/05/18 JB HT
LIGHTING FIXTURE SCHEDULETYPE DESCRIPTION VA LAMP(S) LUMINOUS FLUX COLOR TEMP.
A1
LED EXIT SIGN, EDGE-LIT DESIGN, CEILING OR WALL MOUNTED WITH RED LETTERS, UNIVERSALVOLTAGE (120-277V).
STATIC RECESSED 2 X 2 DIRECT/INDIRECT TYPE LED FIXTURE WITH CENTER MOUNTEDCONCEALED ILLUMINATION PERFORATED BASKET. HOUSING SHALL BE PAINTED WITH WHITEPOLYESTER POWDER OR BAKED ENAMEL. UNIVERSAL VOLTAGE (120-277V).
B1 4' SUSPENDED DIRECT/INDIRECT TYPE LED FIXTURE WITH PERFORATED BASKET. HOUSINGSHALL BE PAINTED WITH WHITE POLYESTER POWDER OR BAKED ENAMEL. UNIVERSALVOLTAGE (120-277V).
2' LED WRAP. PAINTED WITH WHITE POLYESTER POWDER OR BAKED ENAMEL. WALLMOUNTED ABOVE DOOR. UNIVERSAL VOLTAGE (120-277V).
F1
D1 6" LED DOWNLIGHT. UNIVERSAL VOLTAGE (120-277V).
X1 2.7 LED - -
CRI DIMMINGIMAGE
A2
LED 3500K
22 LED 2200 lm 3500K 90 CRI
18 LED 2070 lm 3500K >80 CRI
90 CRI23 LED 1786 lm 3500 K
32 3200 lm 90 CRI
-
0-10V
0-10V
0-10V
0-10V
D2 2'' LED WALLWASH, 45 DEGREE CUTOFF. 120V 90 CRI22.3 LED 1200 lm 3500 K 0-10V
STATIC RECESSED 2 X 4 DIRECT/INDIRECT TYPE LED FIXTURE WITH CENTER MOUNTEDCONCEALED ILLUMINATION PERFORATED BASKET. HOUSING SHALL BE PAINTED WITH WHITEPOLYESTER POWDER OR BAKED ENAMEL. UNIVERSAL VOLTAGE (120-277V).
5000 lmLED50A2 3500K 90 CRI 0-10V
X2 LED EXIT SIGN, EDGE-LIT DESIGN, CEILING OR WALL MOUNTED WITH RED LETTERS, CHEVRONDIRECTIONAL ARROWS, UNIVERSAL VOLTAGE (120-277V).
LED - - -2.7
E1 LED2'x4' LED FIXTURE FROM SALVAGE. REFER TO ED SERIES DRAWINGS FOR ADDITIONALINFORMATION.
2200 lm 3500 K 90 CRI STEPDIMMING
17.8
S1 2' LED STRIPLIGHT, FROSTED REFRACTOR, WHITE HOUSING. 3500 K COLOR TEMPERATURE.120-277V.
10 LED 800 lm 3500K 85 CRI 0-10V
W1 ARCHITECTURAL SCONCE. DARK WALNUT FINISH. LOW VOLTAGE, 12V WITH TRANSFORMER 12.5 LED 860 lm 2700 K 90 CRI LOWVOLTAGE
3
EI-001
SINGLE ROOM LIGHTING CONTROLSN.T.S.
1
EI-001
EXIT SIGN - CEILING MOUNTEDN.T.S.
2
EI-001
LUMINAIRE DETAIL - CEILING MOUNTEDN.T.S.
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
T
J
C6LE2
3
C6LE34
C6AC1
C6162
C6001
C6002
C6041
C6-24
C6003
C6006 C6007 C6008 C6009 C6010
C6011C6012C6013C6014C6015
C6018
C6020
C6021
C6023
C6024
C6025
C6027
C6028
C6030
C6032
C6033
C6034
C6016
C6005
C6LE1-5
C6LE1-19
C6LE1-21
C6LE1-3
C6LE1-25C6LE1-27C6LE1-38C6LE1-40C6LE1-42
C6LE1-23C6LE1-32C6LE1-34C6LE1-36
C6LE1-11
7
C6LE1-26
C6LE2-1
C6004C6LE2-5
C6LE2-9
C6LE2-19C6LE2-25
C6LE2-33
C6019C6LE2-2
C6017C6LE2-4
C6LE2-41
C6LE2-12
C6LE2-14
C6LE2-16C6LE2-18
C6LE2-26
C6LE2-30
C6LE2-28
C6LE2-40
C6LE2-42
C6LN1-20C6LN1-22C6LN1-24
C6LN1-15
?
C6LE2-8
C6LE2-20
C6LE2-10
C6LE2-24
C6016
C6LE2-6
C6LN1-18
C6HEX
C6LN1
C6LE1
56
6
6
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:10:2
0 P
M
ED-106
PARTIAL SIXTH FLOORDEMOLITION PLAN
10/05/18 JB HT
1/8" = 1'-0"ED-106
1 PARTIAL SIXTH FLOOR DEMOLITION PLAN
1. NOTE NOT USED.2. NOTE NOT USED.3. DISCONNECT AND REMOVE SWITCHES AND ASSOCIATED WIRING BACK TO
SOURCE OR NEAREST ACTIVE DEVICE. TYPICAL FOR ALL DEVICES WITHINAREA OF GENERAL DEMOLITION.
4. DISCONNECT AND REMOVE EXISTING ABANDONED PANELBOARD. REMOVEALL ASSOCIATED CONDUIT AND WIRE.
5. DISCONNECT AND REMOVE EXISTING PANELBOARD BACK TO SOURCE.REMOVE CONDUIT AND WIRE BACK TO SOURCE AND DOWNSTREAM OFPANEL.
6. DISCONNECT AND REMOVE PANEL. EXISTING TO BE REPLACED. REFER TOPOWER PLANS AND PANELBOARD SCHEDULES.
7. DISCONNECT 120V POWER TO TECHNOLOGY PANELS BACK TO SOURCE.REFER TO TECHNOLOGY DRAWINGS FOR PANEL LOCATIONS.
DRAWING NOTES:
A. UNLESS NOTED OTHERWISE, DISCONNECT AND REMOVE EXISTINGELECTRICAL DEVICES, LIGHTING FIXTURES AND ALL ASSOCIATED CONDUITAND CABLING IN AREAS SHOWN TO BE DEMOLISHED. REMOVE CONDUIT ANDWIRE BACK TO SOURCE OR LAST ACTIVE DEVICE. MAINTAIN CONDUIT ANDWIRE TO ELECTRICAL DEVICES AND LIGHTING FIXTURES WHICH ARE TOREMAIN. REWORK CONDUIT AND WIRE AS REQUIRED TO MAINTAINOPERATION OF DEVICES TO REMAIN.
B. ALL DEMOLISHED MATERIAL SHALL BE REMOVED FROM SITE UNLESSNOTED TO BE RE-USED OR TO BE SALVAGED AND TURNED OVER TOOWNER.
C. IF CIRCUITING IS NOT RE-USED, REMOVE CONDUIT & WIRING BACK TOPANELBOARD & MARK CIRCUIT BREAKER AS 'SPARE'.
GENERAL NOTES:
0
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
3
C7AC1
C7005
C7009
C7010
C7016C7015C7013C7-9
C7018C7022
C7044
C7045
C7039
C7033
C7053
C7034
C7056
C7-11
C7011
C7020
C7019C7023
C7031
C7035
C7054C7015
C7027
C7LE1-14
C7LE1-3
C7LE1-37
C7LE2-2C7LE1-31
C7LE2-4C7LE1-25 C7LE1-41
C7LE1-39
C7LE1-30 C7LE1-28C7LE2-6
C7LE2-14C7LE2-12
C7LE2-23C7LE1-33
C7LE2-1
C7LE2-5C7LE2-15
C7LE2-3
C7LE2-11
C7LE2-17
C7LE2-19C7LE2-9C7LE1-6
C7LE2-25C7LE2-16C7LE2-18
C7LE2-13
C7LE1-20
C7LE2-7
C7LE1-19
C7179
C7002
C7001
C7003
C7004C7058
C7057
C7055
C7051
C7049
C7048
C7047
C7046
C7043
C7042
C7041
C7040
C7038
C7037
C7036
C7032
C7030
C7029
C7026 C7025 C7021
C7014C7012C7008
C7007
C7006
C7028 C7024
C7050
C7LE1-23
4
4
4
5
C7LE4
C7LN1
C7LE1
C7LE24
6J
C7LN1-12
C7LN1-10
C7LN1-28C7LN1-30
C7LN1-40C7LN1-38C7LN1-36
C7LN1-37C7LN1-22C7LN1-20
C7LN1-39
C7LN1-7
C7LN1-24
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:10:2
5 P
M
ED-107
PARTIAL SEVENTH FLOORDEMOLITION PLAN
10/05/18 JB HT
1/8" = 1'-0"ED-107
1 PARTIAL SEVENTH FLOOR DEMOLITION PLAN
1. NOTE NOT USED.2. NOTE NOT USED.3. DISCONNECT AND REMOVE SWITCHES AND ASSOCIATED WIRING BACK TO SOURCE OR
NEAREST ACTIVE DEVICE. TYPICAL FOR ALL DEVICES WITHIN AREAS OF GENERALDEMOLITION.
4. DISCONNECT AND REMOVE PANEL. EXISTING TO BE REPLACED. REFER TO POWER PLANSAND PANELBOARD SCHEDULES.
5. DISCONNECT AND REMOVE POWER TO PUMPS AND ELECTRIC WATER HEATER BACK TOC7LE4. WATER HEATER AND PUMPS TO BE RELOCATED.
6. WORK WITHIN PANEL PROHIBITED. ANY CIRCUITS HOMERUN TO EXISTING PANEL MADESPARE TO BE TERMINATED IN JUNCTION BOX ABOVE CORRIDOR CEILING. PROVIDEPHENOLIC TAG TO READ "C7AC1 SPARE CIRCUITS ABOVE".
DRAWING NOTES:
A. UNLESS NOTED OTHERWISE, DISCONNECT AND REMOVE EXISTING ELECTRICAL DEVICES,LIGHTING FIXTURES AND ALL ASSOCIATED CONDUIT AND CABLING IN AREAS SHOWN TO BEDEMOLISHED. REMOVE CONDUIT AND WIRE BACK TO SOURCE OR LAST ACTIVE DEVICE.MAINTAIN CONDUIT AND WIRE TO ELECTRICAL DEVICES AND LIGHTING FIXTURES WHICHARE TO REMAIN. REWORK CONDUIT AND WIRE AS REQUIRED TO MAINTAIN OPERATIONOF DEVICES TO REMAIN.
B. ALL DEMOLISHED MATERIAL SHALL BE REMOVED FROM SITE UNLESS NOTED TO BE RE-USED OR TO BE SALVAGED AND TURNED OVER TO OWNER.
C. IF CIRCUITING IS NOT RE-USED, REMOVE CONDUIT & WIRING BACK TO PANELBOARD &MARK CIRCUIT BREAKER AS 'SPARE'.
GENERAL NOTES:
0
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
1
C-9036
C-9032
C-9030
C9-4
C9-5
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:10:2
7 P
M
ED-109
PARTIAL NINTH FLOORDEMOLITION PLAN
10/05/18 JB HT
1/8" = 1'-0"ED-109
1 PARTIAL NINTH FLOOR DEMOLITION PLAN
DRAWING NOTES:1. REMOVE EXISTING LIGHTING FIXTURES AND SALVAGE
FOR RECONNECTION. MAKE SAFE WIRING TOFIXTURES FOR CONNECTION TO RELOCATED LIGHTFIXTURES. REFER TO EL-109 FOR NEW LAYOUT.
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
OC
OC
OC
OC
OC OC
OC
OC
OC OC
OC
OC
OC
OC
OC
C6031
C6-24
C6001
C6002
C6002A
C6006
C6004
C6005
C6007 C6008
C6010
C6011
C6012
C6013C6014C6015
C6017
C6019
C6021
C6023
C6024
C6028
C6029
C6030
C6032
C6009
C6027
C6022
C6026
C6025
C6016
C6-23
C6020
S2-6
S1-6
C6LE2
OCOC
OCOC
OCOC
OC OC
OC
OC
OC
OC
OC
OCOC
CORRIDOR DUALSWITCHING
A2
A2
A2A2
A2A2
A1 A1
A2
A2
A2A2
A2A2
A2
A2
A2
A2A2
A2 A2
A2
A2
A2
A2
A2
E1E1
A2
E1
A2 A2
A2 A2
A2
A2
A2A2
A2 A2
A2
A2
E1 E1E1 E1
C6LN1
X1
X2
X1
X1
C6HEX
C6LLS1
C6LE1
C6LN3
d
d d
d d
1313
13
11 11 11
1111
1111
11
11
11
1 1111 1
11 11 1
11
9
9
99
9 9
9 99
9
99
99
9 9 9 9
9
13
13
13
13
13
1
1
1
1
13
13
11
1
9
9
1
9
9
1
9
9
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
E1
F113
F1
11
1
C6007
1
E1
A2
A211
A2
A2A2
A2A2
A2A2
A2A2
A2
11
11
11
11
11
11
11
11
11
11
A21
A213
A2 A2
A2
A2
A2
A2
A2
A2
A2
A21111
11 11
9
99
11
13
13
9
OC
A2A2
A2 A2
A2
13 13
113
13
A211
A2 A2A2
A2
A2
A2A2
A2 A2
A2
A2
9
99 9
9
9 9
99
11
11
A2
A2
9
9
1A2
a a a
aaa
a
bb
b b
bbb
c c
c
OC
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:10:3
4 P
M
EL-106
PARTIAL SIXTH FLOOR LIGHTINGPLAN
10/05/18 JB HT
1/8" = 1'-0"EL-106
1 PARTIAL SIXTH FLOOR LIGHTING PLAN
CIRCUITING LEGEND:
CIRCUIT ALL LIGHTING TO THE FOLLOWING PANELS:NORMAL: C6LN1EMERGENCY: C6LE1
NOTE:
1. EMERGENCY FIXTURES ARE DESIGNATED WITH HATCH.2. CIRCUIT FIXTURES TO CIRCUIT NUMBER LISTED IN PLAN WITH
PANEL ABOVE.
DRAWING NOTES:0
1. PROVIDE (3)#12, #12G, 3/4"C. REFER TO 4/EL-107 FOR DIAGRAM.
ROOM SCHEDULE - 6TH FLOOR
Number Name
C6-23 CORRIDOR
C6-24 CORRIDOR
C6-25 CORRIDOR
C6-30 CORRIDOR
C6-31 CORRIDOR
C6-32 LOBBY
C6-33 CORRIDOR
C6001 LEARNERS
C6002 MD OFFICES
C6002A CHIEF
C6004 TLT RM
C6005 TLT RM
C6006 BREAK RM
C6007 CONF RM
C6008 PHYS
C6009 LEARNERS
C6010 NP
C6011 CHIEF
C6012 RN
C6013 LEARNERS
C6014 PHYS
C6015 MD OFFICE
C6016 MD OFFICES
C6017 MD OFFICE
C6018 MECH RM
C6019 MSA'S
C6020 VESTIBULE
C6021 BUS MNGR
C6022 CONFERENCE
C6023 PRACTICE MNGR
C6024 CHIEF
C6025 CHIEF
C6026 N CHIEF
C6027 N CHIEF
C6028 MSA SUPV
C6029 PSA
C6030 MD OFFICE
C6031 MECH. ROOM
C6032 MD OFFICE
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
OC
OC
OC
OC
OC
OC
OC
OC
OC OC
OC
OC
OC
OC
OC
OCD
D
D
D
D
D
DD
D
D
D
OC
E1
A1
A1
A1
A1
A1 A1
A1
A1
E1
E1
A2 A2
A2
A2
A2
A2
A2
A2
A2 A2
A2
A2
A2
A2
A2
A2A2
A2A2
A2
E1
E1
E1
A2
A2
D1
D1
D1
D1
D1
D1
A1
A1
A1
D1
D1
D1
D1
A2
A2
A2
A2
A2
A2
A2
A2
A2
D1
D1
D1 D1
1
X1
X1
EL-1073
C7LE4
C7LE2
C7LN1
C7LE1
C7AC1
C7LL1
C7HEX
C7034
C-7178
C7-8
C-7077
C-7138
C-7139
C7-25
C-7076
C7-7
S1-7
C7010
48
C7001
C7001A
C7003A
C7003
C7005
C7006
C7008
C7-11
C7009
C7011 C7012C7013
C7014 C7015 C7016
C7017C7018C7019C7020C7021C7022
C7023
C7025
C7024
C7-9
C7040
C7026
C7027
C7028
C7029
C7030
C7031
C7032C7033
C7035
C7036
C7037A
C7037
C7039
S2-7
C7007
C-7059
C-7075
C7-10
A2
A2 A2
A2
A2
A2
A1
E1 E1 E1 E1
A2 A2
A2A2
A2
A2
DOCD D D D D
DD
OC
OCDDD
34
34
3434
34
34
34
2
34 34
34
2
34
34
2
34
2
2
34
34
3434
34
34
34
40
40 40
40
40
40
2
40
40
40
40
40402402
40
40
40
40
34
11 11
11
11 11
1111
1111
11
11
11 11
2
11111111
1111
34 34
342
2
34
3434
11 11
c d
c
c
c
c
d
d
d
d
c
a
a
a
a
a
a
a
a
b
b
b
a
c
c
d
E1
F134
11
F134
OC
E111
E12
34 2
34
342
34
34
34
F1 F1
F1
F1
F1
F1
F1
F1
2
C7LE1
E111
E1
E1
E1
E1
A2 A2
A2A2
11 11
1111
11
2
11
2
40A2
40 40 40
40
40
40
A2 A2 A2
A2A2
A2
34
34
34
34
34
D1
D1
D1
D1
D1
D2
D2
34
34
D134
2F1
34
D2
D2
D2
34
34
b
D234
D234
S1
S1
S1
S1
S1
S1
S1
S1S1S1S1
11 11
11
11
11
S111
40
40 40S1S1
40
40404040
2 2
A2
A2
A2
40
40 40
2
34
2
E1
E1
E1
A2 A2
D1
D1
D1
D1
11
11
11
11
2X1
X12
X12
X12
2
E140
E12
11 11
34
S111
S111
34E1
W1 W134 34
34
34
W1
W1
D
D
D
c
d
a
d c
dc
3
zz
zzy
yy
y
y
x
x
x
zy
y y
y y
z
y yy
zz
y y
z
y
x
x
z
z
y
y y
z
y
zz
y y
z
yz
y y
z
y
y
y
z
y
y
y
z
y
z
y
y
z
y
y
y
z
z
z
z
y
y
y
z
z
y
y
yy
y
y
z
z
z
z
y
y
y
y
x
x
z
EL-1072
ALT. E-1
ALTERNATE-1
ALTERNATE-1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
B1
34 34 34 43 34 34 34
43 34 34 34 34 34 43
34 34 34 43 34 34 34
8686
NURSES STATION
SCONCESa
bCORRIDORDUALSWITCHING
2c
d
LINE
L1
L2
L1
L2
L1
L2
N
G
G
N
E1 E2
CONT.
N
G
c
d
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:10:4
3 P
M
EL-107
PARTIAL SEVENTH FLOORLIGHTING PLAN
10/05/18 JB HT
1/8" = 1'-0"EL-107
1 PARTIAL SEVENTH FLOOR LIGHTING PLAN 1/8" = 1'-0"EL-107
2 PARTIAL FLOOR LIGHTING PLAN ALTERNATE-1
1/2" = 1'-0"EL-107
3 DETAIL
1. FIELD ADJUST OPTICS TO ACCENT FEATURE WALLS AND CORRIDOR SPACE.COORDINATE WITH ARCHITECTURAL FINISHES. ARROW INDICATES ROUGHDIRECTIONALITY.
2. PROVIDE (3)#12, #12G, 3/4"C DAISY-CHAINED TO EACH CORRIDOR FIXTURE INPARALLEL. REFER TO 4/EL-107 FOR DIAGRAM.
3. NON-EMERGENCY FIXTURES ENCLOSED WITHIN THIS REGION ARE CIRCUITEDTO PANEL C7AC1.
DRAWING NOTES:0
CIRCUITING LEGEND:CIRCUIT ALL RECEPTACLES TO THE FOLLOWING PANELS:NORMAL: C7LN1, C7AC1EMERGENCY: C7LE1
NOTE:1. EMERGENCY FIXTURES ARE DESIGNATED WITH HATCH.2. CIRCUIT FIXTURES TO CIRCUIT NUMBER LISTED IN PLAN WITH PANEL ABOVE.
3/4" = 1'-0"EL-107
4 DUAL SWITCH WIRING DIAGRAM
ROOM SCHEDULE - 7TH FLOOR
Number Name
C7-6 CORRIDOR
C7-7 CORRIDOR
C7-8 CORRIDOR
C7-9 CORRIDOR
C7-10
C7-10A SHELL SPACE
C7-11 CORRIDOR
C7-25 FREIGHT ELEVATORS LOBBY
C7001 LOCKERS
C7002 STAFF TLT
C7003 LOCKERS
C7004 STAFF TLT
C7005 BREAK RM /MAIL RM
C7006 HSKP
C7007 WAITING ROOM
C7008 PAT TLT
C7009 RECEPT
C7010 CHECK OUT
C7011
C7012 EXAM
C7013 TYPICAL TEAM RM
C7014 TLT RM
C7015
C7016 EXAM
C7017 EXAM
C7018
C7019 EXAM
C7020 EXAM
C7021
C7022
C7023
C7024
C7025
C7026
C7027 EXAM RM
C7028
C7029
C7030 TEAM RM
C7031
C7032 EXAM RM
C7033 EXAM RM
C7034 STOR
C7035 EXAM/PROC ROOM
C7036 PAT TLT
C7037 EXAM/PROC
C7038 PAT TLT
C7039
C7040 MECH RM
CORRIDOR
EXAM
EXAM
TEAM RM
TEAM RM
EXAM
STOR
ELEC
SOILED HOLDING
TEAM RM
TYPICAL EXAM RM
EXAM RM
EXAM RM
CLEAN STORAGE
EXAM
EXAM
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
A2 A2
A2A2
A2 A2
A2A2
E1E1
E1
E1
E1
1
C-9036
C-9032
C-9030
C9-4
C9-5
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:10:4
6 P
M
EL-109
PARTIAL NINTH FLOOR LIGHTINGPLAN
10/05/18 JB HT
1/8" = 1'-0"EL-109
1 PARTIAL NINTH FLOOR LIGHTING PLAN
DRAWING NOTES:
1. EXTEND/RECONNECT POWER TO RELOCATED LIGHTING FIXTURE.TYPICAL FOR THIS FIXTURE TYPE.
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
J
1
GFI GFI
GFIGFI
GFI
2
2
2
3
C6LE24
WIREWAY,FLUSHWITH TILE
1
5
1
C6LN1
C6LE1
C6AC1
C6LLS1
BUS DUCT
C6HEX
BP-1
BP-2
EWH-1
C7LE4-25,27,29
4
4
C6LN3
1 1 1
9
2
4
2
4
9 3
3
9
5
5
9
5
9
6
66
7
8
10
10
10
910
10
11
11 11
13
1212
12
11
1313
15 15
15
14
11
17
17
17
11
11
14
18
1818
19
19
2011
11
19
20
21
21
21
22
43
22
19
22
23
19
2324
2424
27
2519
25
272719
26
28
26
28 28
3030
29
30
31
31
1932 32
32
3333
33
33
3434
33
34
33
36
3333
36
33
37
37
41
41
38
41
3839
39 39
40 40
4041
4141
41
26
19
41 6
42
42
42
35
VAV-1
VAV-2
VAV-3
VAV-4
VAV-5
VAV-6
VAV-7
VAV-8
VAV-9
VAV-11
VAV-10
VAV-12
VAV-13
VAV-14VAV-15VAV-17 VAV-16
VAV-18
VAV-19
VAV-20
CAV-21VAV-22
VAV-23
VAV-24
VAV-25
VAV-26
VAV-27
VAV-28
VAV-29
43
22
9
EE
EE
E
E
E
E E
EE
E
E
E
E
EE
E
E
E
E
E
E
E
E
E
E
E
E
6
C6LE1-3
2
3
11
24
35
RECEPTACLEFOR RCP-1
C7LE4-3
7
VAV-62
CAV-61
VAV-64
GFI
16
16
16
16
16
16
16
1616
16
15
15
15
15 1515 15
15
15
15
1818
18
18
18
18
18
18
18
1818
GFI
POWER TO FD-3C6LE2-2
C6LE2-4
POWER TOFD-1
POWERTO FD-2C6LE2-4
C6LE2-2POWER TO FD-4
POWER TO FD-6
POWER TO FD-7
POWER TO FD-8C6LE2-6
C6LE2-8
C6LE2-10
C7LE4-16,18,20
C7LE4-19,21,23
10 10FV FV10 10
SV
SV
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:10:5
1 P
M
EP-106
PARTIAL SIXTH FLOOR POWERPLAN
10/05/18 JB HT
1/8" = 1'-0"EP-106
1 PARTIAL SIXTH FLOOR POWER PLAN
1. TV WALL BOX, CONCEALED BEHIND TELEVISION. COORDINATE FINAL INSTALLEDELEVATION WITH TELEVISION PLACEMENT. RECESS RECEPTACLE WITHIN TV WALLBOX.PROVIDE POWERFROM DUAL DUPLEX TO JUNCTION BOX ABOVE CEILING.
2. POWER DATA AND FLOORBOX INSTALLED FROM CEILING BELOW. PROVIDEQUADRAPLEX.
3. PROVIDE 3.7" IN-CARPET STYLE WIREWAY. SYSTEM SHALL NOT DISTURB SLAB ANDSHALL BE INSTALLED FLUSH WITH SURFACE OF TILE. PROVIDE FULL SYSTEMCOMPLETE WITH REMOVABLE TRACK, MODULAR QUAD RECEPTACLE; COORDINATEMODULAR DEVICES WITH AV REQUIREMENTS. PROVIDE RAMPS, TRACK, WALL TRIM,AND ALL NECESSARY APPURTENANCES. REFER TO DETAILS FOR ADDITIONALINFORMATION.
4. PROVIDE NEW PANEL TO REPLACE EXISTING, PER SINGLE LINE AND PANELSCHEDULES. RECONNECT FEEDERS AND CIRCUITRY REMAINING FROM DEMOLITION.
5. PROVIDE #4 GROUND CABLE FROM EXISTING SIGNAL CLOSET TO NEW CABLE TRAY.REFER TO 'T' DRAWINGS FOR CABLE TRAY.
6. PROVIDE EMERGENCY POWER TO SMOKE DAMPER PER MANUFACTURERSINSTRUCTIONS. DAMPER TO CLOSE UPON SMOKE DETECTION.
DRAWING NOTES:
A. POWER PANEL DOOR SCHEDULES MUST BE UPDATED TO REFLECT THE CHANGES TOTHE ROOM NAMES AND NUMBERS AS A RESULT OF THIS SCOPE OF WORK.
B. CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO ANY FABRICATION ORCONSTRUCTION.
C. CONTRACTOR TO NOTIFY OWNER REPRESENTATIVE OF ANY DISCREPANCIES ANDOBTAIN OWNER APPROVAL FOR ANY CHANGES.
D. ELECTRICAL DEVICE LOCATIONS ARE APPROXIMATE. COORDINATE WITH EQUIPMENT INAREA AND OWNER FOR FINAL DEVICE LOCATIONS.
E. CONDUIT TO BE FIELD ROUTED. PROVIDE PULL BOXES AS REQUIRED PER NEC ORCONSTRUCTION CONDITIONS.
F. CONTRACTOR TO SIZE CONDUIT AND CONDUCTORS BASED UPON MAXIMUMALLOWABLE LOAD FOR CIRCUIT BREAKER SIZE SHOWN AND DE-RATING FACTORSREQUIRED FOR FILL AND VOLTAGE DROP.
G. PROVIDE SEPARATE INSULATED EQUIPMENT GROUNDING CONDUCTOR WITHIN EACHFEEDER AND BRANCH CIRCUIT RACEWAY. TERMINATE EACH END ON SUITABLE LUG,BUS OR BUSHING.
H. CONTRACTOR TO PROVIDE ALL NECESSARY SUPPORTS TO FACILITATE INSTALLATIONOF THEIR DISCIPLINE EQUIPMENT, INDEPENDENT OF OTHER DISCIPLINES.
I. PROVIDE TAMPER-RESISTANT RECEPTACLES IN BUSINESS OFFICES, CORRIDORS,WAITING ROOMS AND THE LIKE IN CLINICS, MEDICAL AND DENTAL OFFICES ANDOUTPATIENT FACILITIES.
GENERAL NOTES:
0
CIRCUITING LEGEND:
CIRCUIT RECEPTACLES TO THE FOLLOWING PANELS:NORMAL: C6LN3EMERGENCY: C6LE2
NOTE:
1. EMERGENCY RECEPTACLES ARE DESIGNATED BY THE LETTER 'E'.2. CIRCUIT FIXTURES TO CIRCUIT NUMBER LISTED IN PLAN WITHIN PANEL ABOVE.3. PROVIDE POWER TO VAVs FROM PANEL C6LN1 AND CIRCUIT INDICATED.
ROOM SCHEDULE - 6TH FLOOR
Number Name
C6-23 CORRIDOR
C6-24 CORRIDOR
C6-25 CORRIDOR
C6-30 CORRIDOR
C6-31 CORRIDOR
C6-32 LOBBY
C6-33 CORRIDOR
C6001 LEARNERS
C6002 MD OFFICES
C6002A CHIEF
C6004 TLT RM
C6005 TLT RM
C6006 BREAK RM
C6007 CONF RM
C6008 PHYS
C6009 LEARNERS
C6010 NP
C6011 CHIEF
C6012 RN
C6013 LEARNERS
C6014 PHYS
C6015 MD OFFICE
C6016 MD OFFICES
C6017 MD OFFICE
C6018 MECH RM
C6019 MSA'S
C6020 VESTIBULE
C6021 BUS MNGR
C6022 CONFERENCE
C6023 PRACTICE MNGR
C6024 CHIEF
C6025 CHIEF
C6026 N CHIEF
C6027 N CHIEF
C6028 MSA SUPV
C6029 PSA
C6030 MD OFFICE
C6031 MECH. ROOM
C6032 MD OFFICE
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
J
E
E
E
E
E E
E
E
GFIE
E
E
GFIGFI
E
E
EE
E
GFIE
E
E
E E
E E
E
E
GFI
GFIGFIGFI
GFI
GFI
8POWER TO 600lb PATIENT LIFT
3
C7AC1
C7LN1
C7LE1
4
5 4
6
AHU-70
EP-1072
C7LE4
C7032C7033
C7035
C7031
C7030
C7036
C7037A
C7029
C7037
C7028
C7027
C7039
C7026S2-7
C7025
C7022
C7020C7021
C7018C7019
C7017
C7-11
C7016
C7015C7014C7013C7012
C7011C7009
C7-9
C7007
C7008
C7005
C7006
C7-8
C7003
C7001
C7001A
C7003A
C7-25
C-7139C-7138
C7-7
C-7077
C7-9
C7023
48
9
C7LE2
C7LL1
E
E
E
E
E
E
E
E
E
E
E
E
E
C7HEX
E
2
2
2
2
7
7
7
7
7
7
1012
22 2220
22
24
24
2
2
2 26
3
3
3
3
28
3
28
28
30 4
4 5
4 5
5
6
6
3232
67
7
9
9
9
3236
11
36
36
11
36
37 37
37
3811
1112
12 12
1213
13 13
14 14
14
38
1438
39
15
39
15
16
16 1617
17 17
18
1919
1010
1921
19
1938
21
37
14
1214
12
1
1
9
15
6
E
E
E
E
EE
EE
EE
E
E
E
VAV-53
VAV-60
VAV-59
VAV-58
VAV-56
VAV-57
VAV-55
VAV-51
VAV-48VAV-30
VAV-31
VAV-32
VAV-33
VAV-36
VAV-34
VAV-37
VAV-39
VAV-38
VAV-35
VAV-40
VAV-42
VAV-41
26
7
POWER TO 600lb PATIENT LIFT 8
E
E
E
E
C7LE1-3
E
E
E
E
22
12
12
14
12
22GFI
1010
10
10
4
+24"+24"
+24"
+24"
+24"
+24"
28
10
10
EF-417
(ABOVE)
C7HEX-25,27,29
C7HEX-1,3,5
AHU-70CONTROLPANEL
7
C7LE1-6
+36" +36"
E 21E
E
21
21 21
E
E
18
18
18 18
+36"
+36"
EF-37
C7HEX-19,21,23
14
VAV-45
CAV-65
E
E
10
10
C7LE2-28
C7LE2-30
13
13
13
13
13
1313
13
13
13
15
15
15
15
15 15
1515
15
15
17
17
17
17
C7LE2-25
POWER TO FD-5
POWER TO FD-9C7LE2-27
GFI
GFI
GFI
GFI
C7LE2-29
POWER TO DOORACTUATOR
10
10
10
10
FV
FV
SVSV
77
7 7
FV
SV
FV
SV
30
30
30
FV
SV
ALT. E-1
1
2828
2E
2828
E2
2E
2E
VAV-51
VAV-45
VAV-53
VAV-48
15
15 15
15
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:10:5
9 P
M
EP-107
PARTIAL SEVENTH FLOOR POWERPLAN
10/05/18 JB HT
1/8" = 1'-0"EP-107
1 PARTIAL SEVENTH FLOOR POWER PLAN 1/8" = 1'-0"EP-107
2 PARTIAL SEVENTH FLOOR POWER PLAN ALTERNATE - 1
1. SURFACE MOUNT RECEPTACLES IN THIS AREA.2. PROVIDE NEW PANEL TO REPLACE EXISTING, PER SINGLE AND PANEL SCHEDULES.
RECONNECT CIRCUITRY REMAINING FROM DEMOLITION.3. PROVIDE POWER AND CONTROLS AS REQUIRED TO RELOCATED ELECTRIC WATER
HEATER. PROVIDE POWER FROM ORIGINAL SOURCE PER MANUFACTURERREQUIREMENTS.
4. TV WALLBOX, CONCEALED BEHIND TELEVISION. COORDINATE FINAL INSTALLEDELEVATION WITH TELEVISION PLACEMENT. RECESS TELEVISION WITHIN TV WALLBOX.PROVIDE POWERFROM DUAL DUPLEX TO JUNCTION BOX ABOVE CEILING.
5. PROVIDE #4 GROUND CABLE FROM EXISTING SIGNAL CLOSET TO NEW CABLE TRAY.REFER TO 'T' DRAWINGS FOR CABLE TRAY.
6. PROVIDE POWER, CONTROLS AND ALL TERMINATIONS FOR AHU PERMANUFACTURER'S INSTRUCTIONS. PROVIDE POWER PER NAMEPLATE DATA. SOURCEFROM C7HEX.
7. PROVIDE POWER, STARTING MEANS AND ALL ASSOCIATED CONTROLS FORRETURN/EXHAUST FAN PER MANUFACTURER'S INSTRUCTIONS. PROVIDE POWER PERNAMEPLATE DATA. PROVIDE 600V 30A 3P, NON-FUSED DISCONNECT.
8. POWER TO PATIENT LIFT. PROVIDE POWER TO JUNCTION BOX ABOVE CEILING TO BEEXTENDED, COORDINATE IN THE FIELD. LABEL JUNCTION BOX CEILING TILE WITHPHENOLIC TAG TO READ "POWER FOR PATIENT LIFT ABOVE".
9. PROVIDE EMERGENCY POWER TO SMOKE DAMPER PER MANUFACTURERSINSTRUCTIONS. DAMPER TO CLOSE UPON SMOKE DETECTION.
10. NON-EMERGENCY FIXTURES ENCLOSED WITHIN THIS REGION ARE CONNECTED TOPANEL C7AC1
DRAWING NOTES:
A. POWER PANEL DOOR SCHEDULES MUST BE UPDATED TO REFLECT THE CHANGES TOTHE ROOM NAMES AND NUMBERS AS A RESULT OF THIS SCOPE OF WORK.
B. CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO ANY FABRICATION ORCONSTRUCTION.
C. CONTRACTOR TO NOTIFY OWNER REPRESENTATIVE OF ANY DISCREPANCIES ANDOBTAIN OWNER APPROVAL FOR ANY CHANGES.
D. ELECTRICAL DEVICE LOCATIONS ARE APPROXIMATE. COORDINATE WITH EQUIPMENTIN AREA AND OWNER FOR FINAL DEVICE LOCATIONS.
E. CONDUIT TO BE FIELD ROUTED. PROVIDE PULL BOXES AS REQUIRED PER NEC ORCONSTRUCTION CONDITIONS.
F. CONTRACTOR TO SIZE CONDUIT AND CONDUCTORS BASED UPON MAXIMUMALLOWABLE LOAD FOR CIRCUIT BREAKER SIZE SHOWN AND DE-RATING FACTORSREQUIRED FOR FILL AND VOLTAGE DROP.
G. PROVIDE SEPARATE INSULATED EQUIPMENT GROUNDING CONDUCTOR WITHIN EACHFEEDER AND BRANCH CIRCUIT RACEWAY. TERMINATE EACH END ON SUITABLE LUG,BUS OR BUSHING.
H. CONTRACTOR TO PROVIDE ALL NECESSARY SUPPORTS TO FACILITATEINSTALLATION OF THEIR DISCIPLINE EQUIPMENT, INDEPENDENT OF OTHERDISCIPLINES.
I. PROVIDE TAMPER-RESISTANT RECEPTACLES IN BUSINESS OFFICES, CORRIDORS,WAITING ROOMS AND THE LIKE IN CLINICS, MEDICAL AND DENTAL OFFICES ANDOUTPATIENT FACILITIES.
GENERAL NOTES:
0
CIRCUITING LEGEND:
CIRCUIT ALL RECEPTACLES TO THE FOLLOWING PANELS.NORMAL: C7LN1EMERGENCY: C7LE2
NOTE:
1. EMERGENCY RECEPTACLES ARE DESIGNATED BY THE LETTER 'E'.2. CIRCUIT FIXTURES TO CIRCUIT NUMBER LISTED IN PLAN WITHIN PANEL ABOVE.3. PROVIDE POWER TO VAVs FROM PANEL C7AC1 AND CIRCUIT INDICATED.
ROOM SCHEDULE - 7TH FLOOR
Number Name
C7-6 CORRIDOR
C7-7 CORRIDOR
C7-8 CORRIDOR
C7-9 CORRIDOR
C7-10
C7-10A SHELL SPACE
C7-11 CORRIDOR
C7-25 FREIGHT ELEVATORS LOBBY
C7001 LOCKERS
C7002 STAFF TLT
C7003 LOCKERS
C7004 STAFF TLT
C7005 BREAK RM /MAIL RM
C7006 HSKP
C7007 WAITING ROOM
C7008 PAT TLT
C7009 RECEPT
C7010 CHECK OUT
C7011
C7012 EXAM
C7013 TYPICAL TEAM RM
C7014 TLT RM
C7015
C7016 EXAM
C7017 EXAM
C7018
C7019 EXAM
C7020 EXAM
C7021
C7022
C7023
C7024
C7025
C7026
C7027 EXAM RM
C7028
C7029
C7030 TEAM RM
C7031
C7032 EXAM RM
C7033 EXAM RM
C7034 STOR
C7035 EXAM/PROC ROOM
C7036 PAT TLT
C7037 EXAM/PROC
C7038 PAT TLT
C7039
C7040 MECH RM
CORRIDOR
EXAM
EXAM
TEAM RM
TEAM RM
EXAM
STOR
ELEC
SOILED HOLDING
TEAM RM
TYPICAL EXAM RM
EXAM RM
EXAM RM
CLEAN STORAGE
EXAM
EXAM
CORRIDOR
EXAM
EXAM
TEAM RM
TEAM RM
EXAM
STOR
ELEC
SOILED HOLDING
TEAM RM
TYPICAL EXAM RM
EXAM RM
EXAM RM
CLEAN STORAGE
EXAM
EXAM
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:10:5
9 P
M
EP-110
PARTIAL TENTH FLOORPENTHOUSE POWER PLAN
10/05/18 JB HT
1/8" = 1'-0"EP-110
1 PARTIAL TENTH FLOOR PENTHOUSE POWER PLAN
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGE
DRAWING NOTES:1. CIRCUIT REINSTALLED PUMPS TO EXISTING CONNECTIONS.
Revisions: Date:
1
1 2
3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:11:0
0 P
M
EP-601
SINGLE LINE DIAGRAM
10/05/18 JB HT
NORMAL POWER RISER DIAGRAM
DRAWING NOTES:1. REMOVE AND REPLACE EXISTING PANELBOARD. FEEDER TO PANEL TO BE LEFT IN
PLACE FOR RECONNECTION. REFER TO PANELBOARD SCHEDULES.2. PROVIDE NEW PANEL.3. PROVIDE CONDUIT AND WIRE FROM C6LN1 TO C6LN3.
0
1
EP-601
SINGLE LINE DIAGRAMN.T.S.
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
1
1
2
1
1
3
4
(3)#2,#8G, 1"C
DRAWING NOTES:1. REMOVE AND REPLACE EXISTING PANELBOARD. FEEDER TO PANEL TO BE
LEFT IN PLACE FOR RECONNECTION. REFER TO PANELBOARD SCHEDULES.2. DISCONNECT AND REMOVE PANEL.3. PROVIDE CONDUIT AND WIRE FROM C6HEX TO C7HEX.4. PROVIDE NEW PANEL C7HEX.
0
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:11:0
1 P
M
EP-602
SINGLE LINE DIAGRAM
10/05/18 JB HT
EMERGENCY POWER RISER DIAGRAM
1
EP-602
SINGLE LINE DIAGRAMN.T.S.
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:11:0
2 P
M
EP-606a
PANEL SCHEDULE - SIXTH FLOOR
10/05/18 JB HT
* LOCK-OUT / TAG-OUT EXISTING CIRCUIT, DISCONNECT AND WIRING REMOVE IN ITS ENTIRETY. DISCONNECT AND REMOVE ABANDONED CONDUIT. EXISTING TO REMAIN LOADS SHALL BE MAINTAINED, WHERE DISCREPANCIES OR UNACCOUNTED FORLOADS EXIST ON CIRCUITS TO BE DEMOLISHED, MAKE NOTE AND NOTIFY VA PROJECT MANAGEMENT OF THE ISSUE.
Notes:
Total Est. Demand Current: 53 A
Total Conn. Current: 50 A
Spare 9330 VA 100.00% 9330 VA Total Est. Demand: 19038 VA
Receptacle 5220 VA 100.00% 5220 VA Total Conn. Load: 18140 VA
Existing Load 3590 VA 125.00% 4488 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 46 A 47 A 59 A
Total Load: 5470 VA 5650 VA 7020 VA
41 RECPTS COPY MACHINE - C6034 RECPTS 6027, 28, 30, 32 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare RECPTS N. CORR. - C6011 42
39 -- LINEN CHUTE - C6019 (EXISTING) 20 A 1 0.2 kVA 0.0 kVA 1 20 A Spare C6009 40
37 -- NURSE CALL PANEL - C6004 (EXISTING) 20 A 1 0.5 kVA 0.0 kVA 1 20 A PRINTER (EXISTING) -- 38
35 -- PBUs - C6011, 12V 20 A 1 1.1 kVA 0.0 kVA 1 20 A PBUs - C6027, 28 (EXISTING) -- 36
33 C6013, 6009, 6012, 6011 RECPTS C6021, 22, 23, 24, 25, 26 20 A 1 1.1 kVA 0.0 kVA 1 20 A PBUs - C6018, 19 (EXISTING) -- 34
31 -- PBUs - C6011, 12 (EXISTING) 20 A 1 1.1 kVA 0.0 kVA 1 20 A PBUs - C6027, 28 (EXISTING) -- 32
29 -- HEATER (EXISTING) 20 A 1 0.8 kVA 0.0 kVA 1 20 A Spare RECPTS E. & N. - C6022, 25 30
27 -- HOT WATER - C6015 (EXISTING) 20 A 1 0.5 kVA 0.0 kVA 1 20 A PBU - C6016, 25, 30 RECPTS N, S C6016, 25, 30 28
25 RECPTS W. C6014 PBU - C6014 (EXISTING) 20 A 1 1.1 kVA 0.0 kVA 1 20 A PBU - C6016, 25, 30 (EXISTING) RECPTS N, S - C6016, 25, 30 26
23 -- PBU - C6006 (EXISTING) 20 A 1 1.1 kVA 0.0 kVA 1 20 A Spare RECPTS - C6022, 24 24
21 -- PBU - C6008 (EXISTING) 20 A 1 1.1 kVA 0.0 kVA 1 20 A IN USE - C6022 -- 22
19 RECPTS - C6014 RECPTS C6015, 16, 17, 19 20 A 1 1.1 kVA 0.0 kVA 1 20 A Spare RECPTS - C6033 20
17 -- IN USE 20 A 1 1.0 kVA 0.0 kVA 1 20 A Spare RECPTS - C6025 18
15 -- PUMPS (EXISTING) 20 A 1 0.5 kVA 0.0 kVA 1 20 A Spare LTS - C6025, 26, 27 16
13 -- Booster - C6015, C6013 (EXISTING) 20 A 1 0.5 kVA 0.0 kVA 1 20 A Spare LTS - C6028, 29, 30 14
11 -- RECPTS C6008, 09, 10, 11, 13, 14 20 A 1 1.1 kVA 0.0 kVA 1 20 A Spare LTS - C6025, 27, 28, 30 12
9 LIGHTS - C6022, 23, 24 RECPTS C6001, 02, 03, 05 20 A 1 1.1 kVA 0.1 kVA 1 20 A FD-7 RECPTS - C6032 10
7 -- C6004 - RECPTS W.(EXISTING) 20 A 1 0.0 kVA 0.1 kVA 1 20 A FD-6 LTS - C6031, 32, 33, 34 8
5 LTS C6004, 05, 41 LTS C6003, 37, 38, 39, 40 (EXISTING) 20 A 1 1.1 kVA 0.1 kVA 1 20 A FD-8 LTS - C6009, 10, 11 6
3 -- RECPTS/LTS. AIR HANDLER (EXISTING) 20 A 1 1.1 kVA 0.1 kVA 1 20 A FD-1, FD-2 LTS - C6008, 12, 13, 15, 17 4
1 RECPT 6041 RECPTS C6037,6038,6040 E,W,S... 20 A 1 1.1 kVA 0.1 kVA 1 20 A FD-3, FD-4 LTS - C6006, 16, 19, 21 2
CKT*
Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*
Demolished Circuit Description CKT
Notes: FEED THRU LUGS
Enclosure: Type 1
Mounting: Surface Wires: 4 Mains: 225 A
Supply From: Phases: 3 Mains Type: MCB
Location: MECH RM C6018 Volts: 120/208 Wye A.I.C. Rating: 10,000 A
New Branch Panel: C6LE2
* LOCK-OUT / TAG-OUT EXISTING CIRCUIT, DISCONNECT AND WIRING REMOVE IN ITS ENTIRETY. DISCONNECT AND REMOVE ABANDONED CONDUIT. EXISTING TO REMAIN LOADS SHALL BE MAINTAINED, WHERE DISCREPANCIES OR UNACCOUNTED FORLOADS EXIST ON CIRCUITS TO BE DEMOLISHED, MAKE NOTE AND NOTIFY VA PROJECT MANAGEMENT OF THE ISSUE.
Notes:
Spare 15864 VA 100.00% 15864 VA Total Est. Demand Current: 126 A
Receptacle 34020 VA 64.70% 22010 VA Total Conn. Current: 157 A
Lighting - Dwelling Unit 36 VA 100.00% 36 VA Total Est. Demand: 45291 VA
Lighting 4131 VA 100.00% 4131 VA Total Conn. Load: 56651 VA
Existing Load 2600 VA 125.00% 3250 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 157 A 161 A 155 A
Total Load: 18779 VA 19255 VA 18616 VA
41 -- -- -- -- 12.1... 0.0 kVA 1 20 A Spare -- 42
39 -- -- -- -- 11.4... 0.0 kVA 1 20 A Spare -- 40
37 C6LN3 125 A 3 10.8... 0.0 kVA 1 20 A Spare -- 38
35 -- Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare -- 36
33 -- Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare -- 34
31 -- C6092 - UNION (EXISTING) 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare -- 32
29 -- NORTH DRINKING FOUNTAINS... 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare -- 30
27 -- RECPTS PBU - C6058 PLUG MOLD... 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare -- 28
25 -- Spare 20 A 1 0.0 kVA 0.9 kVA 1 20 A SOUTH DRINKING FOUNTAINS... -- 26
23 -- Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare GENERAL RECPTS - C6006 24
21 -- RECPTS - C6035 (EXISTING) 30 A 1 0.9 kVA 0.0 kVA 1 20 A Spare GFCI - C6006 22
19 -- RECPTS - C6035 (EXISTING) 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare COFFEE MACHINE - C6006 20
17 -- COMPUTER - C6035 (EXISTING) 20 A 1 0.9 kVA 0.9 kVA 1 20 A VAVs - 6th FLR RECPTS - C6001 18
15 COMPUTER - C6003 VAVs - 6th FLR 20 A 1 0.8 kVA 0.8 kVA 1 20 A VAVs - 6th FLR 16
13 COMPUTER - C6003 LTS - CORR NORTH 20 A 1 0.8 kVA 0.9 kVA 1 20 A RECPTS - C6095 (EXISTING) -- 14
11 LTS - CORR RT WING 20 A 1 1.6 kVA 0.5 kVA 1 20 A LTS (EXISTING) -- 12
9 LTS. - SOUTH CORR 20 A 1 1.8 kVA 0.9 kVA 1 20 A RECPTS - C6094, 95, 93 (EXISTING) -- 10
7 -- RECPTS - C6063 (EXISTING) 20 A 1 0.9 kVA 0.9 kVA 1 20 A RECPTS - 6092 (EXISTING) -- 8
5 -- RECPTS - C6059 (EXISTING) 20 A 1 0.9 kVA 0.9 kVA 1 20 A RECPTS -- 6
3 -- IN USE 20 A 1 1.0 kVA 0.9 kVA 1 20 A RECPTS -- 4
1 -- RECPTS - C6058 (EXISTING) 20 A 1 0.9 kVA 0.9 kVA 1 20 A RECPTS -- 2
CKT*
Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*
Demolished Circuit Description CKT
Notes:
Enclosure: Type 1
Mounting: Surface Wires: 4 Mains: 225 A
Supply From: Phases: 3 Mains Type: MCB
Location: MECH. ROOM C-6033 Volts: 120/208 Wye A.I.C. Rating: 31,000 A
New Branch Panel: C6LN1
* LOCK-OUT / TAG-OUT EXISTING CIRCUIT, DISCONNECT AND WIRING REMOVE IN ITS ENTIRETY. DISCONNECT AND REMOVE ABANDONED CONDUIT. EXISTING TO REMAIN LOADS SHALL BE MAINTAINED, WHERE DISCREPANCIES OR UNACCOUNTED FORLOADS EXIST ON CIRCUITS TO BE DEMOLISHED, MAKE NOTE AND NOTIFY VA PROJECT MANAGEMENT OF THE ISSUE.
Notes:
Total Est. Demand Current: 60 A
Spare 16854 VA 100.00% 16854 VA Total Conn. Current: 58 A
Power 500 VA 100.00% 500 VA Total Est. Demand: 21572 VA
Lighting 383 VA 100.00% 383 VA Total Conn. Load: 20805 VA
Existing Load 3068 VA 125.00% 3835 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 48 A 54 A 73 A
Total Load: 5730 VA 6381 VA 8694 VA
41 -- PBU C6160 (EXISTING) 30 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS C8085 (EXISTING) RECPTS C6001 42
39 -- PBU/RECPTS C6160 (EXISTING) 30 A 1 0.8 kVA 0.0 kVA 1 20 A Spare PBU C6001 40
37 -- RECPT 9TH FLOOR (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS C7025 (EXISTING) PBU C6001 38
35 -- PBU/RECPTS C6160 (EXISTING) 30 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS C6096 (EXISTING) RECPTS C6002 36
33 -- PBU/RECPTS C6160 (EXISTING) 30 A 1 0.8 kVA 0.0 kVA 1 20 A Spare RECPTS C6002 34
31 -- FCU IT 6,7,8,9th FLR (EXISTING) 20 A 1 0.5 kVA 0.0 kVA 1 20 A Spare RECPTS C6002 32
29 -- RECPTS C6160 (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 30 A RECPTS CORRIDOR (EXISTING) -- 30
27 RECPTS C6001 Spare 20 A 1 0.0 kVA 0.8 kVA 1 20 A RECPTS CORRIDOR (EXISTING) -- 28
25 RECPTS C6001 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare RECPTS C6003, 06 26
23 RECPTS C6002 Spare 20 A 1 0.0 kVA 0.8 kVA 1 20 A RECPTS A650 (EXISTING) -- 24
21 RECPTS C6002, 05 Spare 20 A 1 0.0 kVA 0.8 kVA 1 20 A RECPTS A651a (EXISTING) -- 22
19 RECPTS C6001, 03 Spare 20 A 1 0.0 kVA 0.8 kVA 1 20 A RECPTS A651 (EXISTING) -- 20
17 -- RECPTS C6061, 68, 91 (EXISTING) 20 A 1 0.8 kVA 0.5 kVA 1 20 A LTS C6111 (EXISTING) -- 18
15 -- RECPTS C6059 (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS C6093, 94, 95 (EXISTING) -- 16
13 -- RECPTS C6061 (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS C6160 (EXISTING) -- 14
11 LTS C6009 RECPTS C5130 (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS C6058, 59 (EXISTING) -- 12
9 -- Spare 20 A 1 0.0 kVA 0.8 kVA 1 20 A RECPTS C6160 (EXISTING) -- 10
7 -- Spare 20 A 1 0.0 kVA 0.5 kVA 1 20 A TX-C-5 (EXISTING) -- 8
5 LTS C6003, 04, 05 Spare 20 A 1 0.0 kVA 0.5 kVA 1 20 A LTS C6043 (EXISTING) -- 6
3 LTS C6002 JUNCTION BOX - SMOKE DAMPER 20 A 1 0.5 kVA 0.5 kVA 1 20 A LTS C6043 (EXISTING) -- 4
1 -- EMERGENCY LTS. - 6TH FLR 20 A 1 0.4 kVA 0.5 kVA 1 20 A LTS A651 (EXISTING) -- 2
CKT*
Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*
Demolished Circuit Description CKT
Notes: FEED THRU LUGS
Enclosure: Type 1
Mounting: Surface Wires: 4 Mains: 225 A
Supply From: Phases: 3 Mains Type: MCB
Location: MECH. ROOM C-6033 Volts: 120/208 Wye A.I.C. Rating: 10,000 A
New Branch Panel: C6LE1 0 DRAWING NOTES:1. REPLACE EXISTING PANEL. RECONNECT EXISTING FEEDER
AND LOADS AS SHOWN.2. MAINTAIN EXISTING LOADS REMAINING ON CIRCUIT.
EXTEND CIRCUITRY AND RECONNECT TO EXISTING LOADSAS REQUIRED.
3. PROVIDE NEW BREAKER IN AVAILABLE SPACE.
1 1
1
Calculated Existing Calculated Existing
Calculated Existing
2
2 2
2
2
2
2
2
Notes:
Total Est. Demand Current: 62 A
Total Conn. Current: 62 A
Total Est. Demand: 51390 VA
Total Conn. Load: 51390 VA
Spare 51390 VA 100.00% 51390 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 62 A 62 A 62 A
Total Load: 17130 VA 17130 VA 17130 VA
23 -- -- -- 0.5 kVA 8.2 kVA -- -- -- 24
21 -- -- -- 0.5 kVA 8.2 kVA -- -- -- 22
19 SPARE 15 A 3 0.5 kVA 8.2 kVA 3 100 A C7HEX 20
17 -- -- -- 0.5 kVA 0.5 kVA -- -- -- 18
15 -- -- -- 0.5 kVA 0.5 kVA -- -- -- 16
13 EF-32 (EXISTING) 15 A 3 0.5 kVA 0.5 kVA 3 15 A SPARE 14
11 -- -- -- 0.6 kVA 0.6 kVA -- -- -- 12
9 -- -- -- 0.6 kVA 0.6 kVA -- -- -- 10
7 PUMP 1 (EXISTING) 20 A 3 0.6 kVA 0.6 kVA 3 20 A PUMP 2 (EXISTING) 8
5 -- -- -- 6.3 kVA 0.0 kVA -- -- Space 6
3 -- -- -- 6.3 kVA 0.0 kVA -- -- Space 4
1 AHU SF-1 (EXISTING) 90 A 3 6.3 kVA 0.0 kVA -- -- Space 2
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
Notes:
Enclosure: Type 1
Mounting: Surface Wires: 3 Mains: 150 A
Supply From: Phases: 3 Mains Type: MCB
Location: MECH. ROOM C6031 Volts: 480 Delta A.I.C. Rating: 35,000 A
Exist Branch Panel: C6HEX
3
Calculated Existing
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:11:0
3 P
M
EP-606b
PANEL SCHEDULE - SIXTH FLOOR
10/05/18 JB HT
Notes:
Total Est. Demand Current: 62 A
Total Conn. Current: 95 A
Total Est. Demand: 22260 VA
Receptacle 34020 VA 64.70% 22010 VA Total Conn. Load: 34220 VA
Existing Load 200 VA 125.00% 250 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 90 A 95 A 101 A
Total Load: 10800 VA 11360 VA 12060 VA
53 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 54
51 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 52
49 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 50
47 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 48
45 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 46
43 RECPTS C6004 20 A 1 0.5 kVA 0.0 kVA 1 20 A Spare 44
41 RECPTS C6030 20 A 1 1.1 kVA 0.9 kVA 1 20 A RECPTS C6032 42
39 RECPTS C6029 20 A 1 0.9 kVA 0.9 kVA 1 20 A RECPTS C6030 40
37 RECPTS C6026, 27 20 A 1 0.7 kVA 0.7 kVA 1 20 A RECPTS C6028, 29 38
35 RECPTS C6020 20 A 1 0.4 kVA 0.7 kVA 1 20 A RECPTS C6024, 25 36
33 RECPTS C6021, 22 20 A 1 0.9 kVA 0.7 kVA 1 20 A RECPTS C6022, 23 34
31 RECPTS C6019 20 A 1 0.7 kVA 0.9 kVA 1 20 A RECPTS C6019 32
29 RECPTS C6019 20 A 1 0.2 kVA 1.1 kVA 1 20 A RECPTS C6019 30
27 RECPTS C6019 20 A 1 0.9 kVA 1.1 kVA 1 20 A RECPTS C6019 28
25 RECPTS C6017 20 A 1 0.7 kVA 0.9 kVA 1 20 A RECPTS C6019, 17 26
23 RECPTS C6016 20 A 1 0.7 kVA 1.1 kVA 1 20 A RECPTS C6016, 17, GFI WTR COOLER 24
21 RECPTS C6015 20 A 1 1.1 kVA 1.1 kVA 1 20 A RECPTS C6015, 16 22
19 RECPTS C6012, 13 20 A 1 1.1 kVA 0.7 kVA 1 20 A RECPTS C6013, 14 20
17 RECPTS C6010 20 A 1 1.1 kVA 0.9 kVA 1 20 A RECPTS C6012 18
15 RECPTS C6009 20 A 1 1.1 kVA 0.0 kVA 1 20 A Spare 16
13 RECPTS C6008, CORR. 6-24 20 A 1 1.1 kVA 0.5 kVA 1 20 A RECPTS C6008, CORR 6-24 14
11 RECPTS C6005, CORR.6-24 20 A 1 0.9 kVA 1.1 kVA 1 20 A RECPTS C6008 12
9 RECPTS C6004 20 A 1 0.2 kVA 1.1 kVA 1 20 A RECPTS C6004, 06, 07 10
7 GFI - FRIDGE C6004 20 A 1 0.2 kVA 0.2 kVA 1 20 A RECPTS C6004 8
5 RECPTS C6002 20 A 1 0.9 kVA 1.1 kVA 1 20 A RECPTS C6003, 02 6
3 RECPTS C6001, 02 20 A 1 0.9 kVA 0.5 kVA 1 20 A RECPTS C6001 4
1 RECPTS C6001, 02 20 A 1 1.1 kVA 0.7 kVA 1 20 A RECPTS C6001 2
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
Notes: GFI - PROVIDE GFCI CIRCUIT BREAKER.
Enclosure: Type 1
Mounting: Surface Wires: 4 Mains: 125 A
Supply From: C6LN1 Phases: 3 Mains Type: MCB
Location: MECH RM C6018 Volts: 120/208 Wye A.I.C. Rating: 10,000 A
New Branch Panel: C6LN3
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:11:0
5 P
M
EP-607a
PANEL SCHEDULE - SEVENTHFLOOR
10/05/18 JB HT
* LOCK-OUT / TAG-OUT EXISTING CIRCUIT, DISCONNECT AND WIRING REMOVE IN ITS ENTIRETY. DISCONNECT AND REMOVE ABANDONED CONDUIT. EXISTING TO REMAIN LOADS SHALL BE MAINTAINED, WHERE DISCREPANCIES OR UNACCOUNTED FORLOADS EXIST ON CIRCUITS TO BE DEMOLISHED, MAKE NOTE AND NOTIFY VA PROJECT MANAGEMENT OF THE ISSUE.
Notes:
Spare 18781 VA 100.00% 18781 VA Total Est. Demand Current: 83 A
Receptacle 8280 VA 100.00% 8280 VA Total Conn. Current: 83 A
Lighting - Dwelling Unit 640 VA 100.00% 640 VA Total Est. Demand: 30014 VA
Lighting 1938 VA 100.00% 1938 VA Total Conn. Load: 29939 VA
Existing Load 300 VA 125.00% 375 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 83 A 90 A 78 A
Total Load: 9879 VA 10713 VA 9324 VA
41 -- RECPTS C7006 (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS A741 (EXISTING) -- 42
39 FRIDGE - BREAK ROOM RECPTS C7030 20 A 1 0.4 kVA 1.5 kVA 1 20 A LTS- CORR RT WNG, RCPTN, WTNG RM RECPTS C-7003 40
37 RECPTS C7006 RECPTS C7026 20 A 1 0.7 kVA 0.7 kVA 1 20 A RECEPTS C7-9, C7026, 30 RECPTS C-7003 38
35 -- RECPTS C7179 (EXISTING) 20 A 1 0.8 kVA 0.9 kVA 1 20 A RECEPTS C7021, 22 RECPTS C-7003 36
33 -- RECPTS C7177 (EXISTING) 20 A 1 0.8 kVA 1.1 kVA 1 20 A LTS. - NORTH WING, RCPTN, WTNG RM FRIDGE - BREAK RM 34
31 -- RECPTS C7176 (EXISTING) 20 A 1 0.8 kVA 1.1 kVA 1 20 A RECEPTS C7018 RECPTS C7057 32
29 -- RECPTS C7176 (EXISTING) 20 A 1 0.8 kVA 0.5 kVA 1 20 A RECEPTS C7013, 14 LTS C7001 30
27 -- RECPTS C7179 (EXISTING) 20 A 1 0.8 kVA 0.7 kVA 1 20 A RECEPTS C7-11, C7012, 13 LTS C7001 28
25 -- RECPTS C7176 (EXISTING) 20 A 1 0.8 kVA 0.4 kVA 1 20 A RECPTS C7009 RECPTS C7004 26
23 -- RECPTS C7042, 43 (EXISTING) 20 A 1 0.8 kVA 0.4 kVA 1 20 A RECPTS C7005, 06 RECPTS C7058 24
21 -- RECPTS CORR. (EXISTING) 30 A 1 0.8 kVA 1.1 kVA 1 20 A RECPTS C7005 RECPTS C7004 22
19 -- RECPTS C7141 (EXISTING) 20 A 1 0.8 kVA 0.2 kVA 1 20 A GFI ICE MACHINE - C7005 RECPTS C7004 20
17 -- RECPTS C7141 (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS A745 (EXISTING) -- 18
15 -- RECPTS C7141 (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 30 A RECPTS A745 (EXISTING) -- 16
13 -- LTS C7141 (EXISTING) 20 A 1 0.5 kVA 0.8 kVA 1 20 A RECPTS A746 (EXISTING) -- 14
11 -- FCU (EXISTING) 20 A 1 0.5 kVA 0.2 kVA 1 20 A MCRWV - C7005 LTS. C7179 12
9 -- FCU (EXISTING) 20 A 1 0.5 kVA 0.2 kVA 1 20 A GFI FRIDGE - C7005 LTS. C7002 10
7 RECPTS C7001, 03A, 03 20 A 1 1.3 kVA 0.5 kVA 1 20 A LTS DMS C7042, 43, 44, 45 (EXISTING) -- 8
5 -- FCU (EXISTING) 20 A 1 0.5 kVA 0.8 kVA 1 20 A RECPTS A745 (EXISTING) -- 6
3 -- FCU (EXISTING) 20 A 1 0.5 kVA 0.8 kVA 1 20 A RECPTS A746 (EXISTING) -- 4
1 -- FCU (EXISTING) 20 A 1 0.5 kVA 0.8 kVA 1 20 A RECPTS CORR. (EXISTING) -- 2
CKT*
Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*
Demolished Circuit Description CKT
Notes: FEED THRU LUGS, GFI - PROVIDE GFCI CIRCUIT BREAKER.
Enclosure: Type 1
Mounting: Surface Wires: 4 Mains: 225 A
Supply From: Phases: 3 Mains Type: MCB
Location: ELECTR C-7059 Volts: 120/208 Wye A.I.C. Rating: 31,000 A
New Branch Panel: C7LN1
* LOCK-OUT / TAG-OUT EXISTING CIRCUIT, DISCONNECT AND WIRING REMOVE IN ITS ENTIRETY. DISCONNECT AND REMOVE ABANDONED CONDUIT. EXISTING TO REMAIN LOADS SHALL BE MAINTAINED, WHERE DISCREPANCIES OR UNACCOUNTED FORLOADS EXIST ON CIRCUITS TO BE DEMOLISHED, MAKE NOTE AND NOTIFY VA PROJECT MANAGEMENT OF THE ISSUE.
Notes:
Spare 20720 VA 100.00% 20720 VA Total Est. Demand Current: 61 A
Power 0 VA 0.00% 0 VA Total Conn. Current: 60 A
Lighting - Dwelling Unit 54 VA 100.00% 54 VA Total Est. Demand: 21897 VA
Lighting 483 VA 100.00% 483 VA Total Conn. Load: 21769 VA
Existing Load 512 VA 125.00% 640 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 55 A 64 A 65 A
Total Load: 6630 VA 7507 VA 7630 VA
41 RECPTS. C7014 Spare 20 A 1 0.0 kVA 0.5 kVA 1 20 A SIGNAL CIRCUIT (EXISTING) -- 42
39 RECPTS. C7014 Spare 20 A 1 0.0 kVA 0.9 kVA 1 20 A RECPTS CORR. (EXISTING) -- 40
37 RECPTS. - C7004 Spare 20 A 1 0.0 kVA 0.5 kVA 1 20 A LIGHTING (EXISTING) -- 38
35 -- RECPTS A757 (EXISTING) 20 A 1 0.9 kVA 0.5 kVA 1 20 A NURSE CALL (EXISTING) -- 36
33 RECPTS. C7032, 7043 Spare 20 A 1 0.0 kVA 0.5 kVA 1 20 A LTS CORRIDOR (EXISTING) -- 34
31 RECPTS. C7006. LTS C7083 (EXISTING) 20 A 1 0.5 kVA 0.9 kVA 1 20 A RECPTS S. CORRIDOR (EXISTING) -- 32
29 -- RECPTS C7046 (EXISTING) 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare RECPTS C7025 30
27 -- RECPTS C7004, 55 (EXISTING) 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare LTS C7021, 24 28
25 RECPTS. C7012. LTS. C7012 Spare 20 A 1 0.0 kVA 0.5 kVA 1 20 A LTS C7008 (EXISTING) -- 26
23 RECPTS C7008 Spare 20 A 1 0.0 kVA 0.9 kVA 1 20 A RECPTS C7050 LOBBY (EXISTING) -- 24
21 -- RECPTS C7047,46,42,CORR. W (EXIST) 20 A 1 0.9 kVA 0.9 kVA 1 20 A RECPTS A755 (EXISTING) -- 22
19 RECPTS C7057 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare RECPTS C7050 20
17 -- RECPTS C7007, 141A (EXISTING) 20 A 1 0.9 kVA 1.0 kVA 1 20 A RECPTS 7056, LTS 84, 85, 86 (EXISTING) -- 18
15 -- RECPTS C7001, 04, 06, 141A (EXISTING) 20 A 1 0.9 kVA 0.9 kVA 1 20 A RECPTS C7141 (EXISTING) -- 16
13 -- RECPTS C7141, 18, 20 (EXISTING) 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare LTS C7001, 04, 06. RECPTS CORR. W. 14
11 -- RECPTS C7141 (EXISTING) 20 A 1 0.9 kVA 0.5 kVA 1 20 A LTS C7141 (EXISTING) -- 12
9 -- RECPTS C7141 (EXISTING) 20 A 1 0.9 kVA 0.5 kVA 1 20 A LTS A745 (EXISTING) -- 10
7 -- RECPTS C7141A (EXISTING) 20 A 1 0.9 kVA 1.0 kVA 1 20 A LTS A743, A744 RECPTS C7079 (EXIST) -- 8
5 -- RECPTS C7141 (EXISTING) 20 A 1 0.9 kVA 0.0 kVA 1 20 A AHU-70 CONTROL PANEL RECPTS C7042, 46, 47 6
3 LTS 7004, 55, 57, 58 RECPTS 7057, 58 JUNCTION BOX - SMOKE DAMPER 20 A 1 0.0 kVA 0.5 kVA 1 20 A LTS ELECT. CLOSET 7059 (EXISTING) -- 4
1 -- IN USE (EXISTING) 70 A 1 1.0 kVA 0.5 kVA 1 20 A LTS. EMERGENCY - 7TH FLR LTS C7041, 42, 46 2
CKT*
Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*
Demolished Circuit Description CKT
Notes: FEED THRU LUGS
Enclosure: Type 1
Mounting: Surface Wires: 4 Mains: 225 A
Supply From: Phases: 3 Mains Type: MCB
Location: ELECTR C-7059 Volts: 120/208 Wye A.I.C. Rating: 10,000 A
New Branch Panel: C7LE1
Notes:
Spare 4512 VA 100.00% 4512 VA Total Est. Demand Current: 33 A
Receptacle 3060 VA 100.00% 3060 VA Total Conn. Current: 31 A
Lighting - Dwelling Unit 256 VA 100.00% 256 VA Total Est. Demand: 11735 VA
Lighting 1407 VA 100.00% 1407 VA Total Conn. Load: 11235 VA
Existing Load 2000 VA 125.00% 2500 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 31 A 29 A 34 A
Total Load: 3662 VA 3530 VA 4032 VA
17 VAVs - 7th FLR 20 A 1 0.3 kVA 0.0 kVA 1 20 A Spare -- 18
15 VAVs - 7th FLR 20 A 1 0.8 kVA 0.0 kVA 1 20 A Spare -- 16
13 VAVs - 7th FLR 20 A 1 0.8 kVA 0.9 kVA 1 20 A RECPTS C7007 Spare 14
11 LTS - SOUTH CORR & WNG 20 A 1 1.7 kVA 1.1 kVA 1 20 A RECPTS C7007 Spare 12
9 -- FCUs EAST (EXISTING) 20 A 1 0.5 kVA 1.3 kVA 1 20 A RECPTS C7039, 37A, 36 Spare 10
7 -- LTS CORR. N. & E. (EXISTING) 20 A 1 0.5 kVA 0.5 kVA 1 20 A FCU C7121 (EXISTING) -- 8
5 -- FCUs SOUTH (EXISTING) 20 A 1 0.5 kVA 0.5 kVA 1 20 A FCUs WEST (EXISTING) -- 6
3 -- FCUs EAST (EXISTING) 20 A 1 0.5 kVA 0.5 kVA 1 20 A FCUs NORTHWEST (EXISTING) -- 4
1 -- FCUs EAST CENTER (EXISTING) 20 A 1 0.5 kVA 0.5 kVA 1 20 A FCUs W. CENTER 7001 (EXISTING) -- 2
CKT*
Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*
Demolished Circuit Description CKT
Notes:
Enclosure: Type 1
Mounting: Surface Wires: 4 Mains: 250 A
Supply From: Phases: 3 Mains Type: MLO
Location: ELECTR C-7059 Volts: 120/208 Wye A.I.C. Rating: 10,000 A
Existing Branch Panel: C7AC1
* LOCK-OUT / TAG-OUT EXISTING CIRCUIT, DISCONNECT AND WIRING REMOVE IN ITS ENTIRETY. DISCONNECT AND REMOVE ABANDONED CONDUIT. EXISTING TO REMAIN LOADS SHALL BE MAINTAINED, WHERE DISCREPANCIES OR UNACCOUNTED FORLOADS EXIST ON CIRCUITS TO BE DEMOLISHED, MAKE NOTE AND NOTIFY VA PROJECT MANAGEMENT OF THE ISSUE.
Notes:
Total Est. Demand Current: 52 A
Total Conn. Current: 58 A
Spare 5332 VA 100.00% 5332 VA Total Est. Demand: 18653 VA
Receptacle 14580 VA 84.29% 12290 VA Total Conn. Load: 20737 VA
Existing Load 825 VA 125.00% 1031 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 62 A 65 A 49 A
Total Load: 7222 VA 7580 VA 5935 VA
29 Existing Load 20 A 1 0.5 kVA 0.1 kVA 1 20 A PATIENT LIFT PWR 30
27 Spare FD-9 20 A 1 0.1 kVA 0.1 kVA 1 20 A PATIENT LIFT PWR 28
25 RECPTS C7048 FD-5 20 A 1 0.1 kVA 0.5 kVA 1 20 A LTS IN USE (EXISTING) -- 26
23 OVERBED LTS, SP, RECPTS. C7032 CORRIDOR C7-9 20 A 1 0.0 kVA 0.5 kVA 1 20 A PUMP C7025 (EXISTING) -- 24
21 LTS C7040, 41 RECPTS - C7037 20 A 1 1.5 kVA 1.1 kVA 1 20 A RECPTS CORR. (EXISTING) -- 22
19 LTS C7040, 41, 47, 46 RECPTS C7035, 37 20 A 1 0.9 kVA 1.1 kVA 1 20 A RECPTS CORR. N. (EXISTING) -- 20
17 RECPTS C7046 RECPTS C7033 20 A 1 0.7 kVA 1.1 kVA 1 20 A RECPTS C7035 RECPTS C7046, 48 18
15 LTS C7038 RECPTS C7031 20 A 1 0.7 kVA 0.7 kVA 1 20 A RECPTS C7032 RECPTS C7046, 48 16
13 RECPTS C7049 RECPTS C7028 20 A 1 0.7 kVA 0.9 kVA 1 20 A RECPTS C7029, 30 RECPTS C7028, 29, 30 14
11 RECPTS C7042 RECPTS C7022, 26, 27 20 A 1 0.7 kVA 0.9 kVA 1 20 A RECPTS C7026, 27, 28 RECPTS C7026, 30, 49 12
9 RECPTS C7047, C7046 RECPTS C7020, 21 20 A 1 0.9 kVA 1.1 kVA 1 20 A RECPTS C9051, MCRWV (EXISTING) -- 10
7 RECPTS C7048, 49, 51 RECPTS C7019 20 A 1 0.5 kVA 1.1 kVA 1 20 A RECPTS CORR. (EXISTING) -- 8
5 RECPTS C7038 RECPTS C7016 20 A 1 0.5 kVA 0.9 kVA 1 20 A RECPTS C7017, 18 LTS C7025, 26, 27. RECPTS C7028 6
3 RECPTS C7040 RECPTS C7011, 12 20 A 1 0.9 kVA 0.5 kVA 1 20 A RECPTS C7015 LTS C7008, 21 4
1 LTS C7036,37,39 RECPTS C7038 RECPTS C7005 20 A 1 0.4 kVA 1.1 kVA 1 20 A RECPTS C7009 LTS C7032, 06, 07, 08 2
CKT*
Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*
Demolished Circuit Description CKT
Notes: FEED THRU LUGS
Enclosure: Type 1
Mounting: Surface Wires: 4 Mains: 150 A
Supply From: Phases: 3 Mains Type: MCB
Location: ELEC C7025 Volts: 120/208 Wye A.I.C. Rating: 10,000 A
New Branch Panel: C7LE2
0 DRAWING NOTES:1. REPLACE EXISTING PANEL. RECONNECT EXISTING FEEDER
AND LOADS AS SHOWN.2. MAINTAIN EXISTING LOADS REMAINING ON CIRCUIT. EXTEND
CIRCUITRY AND RECONNECT TO EXISTING LOADS ASREQUIRED.
2
Calculated Existing
Calculated Existing
Calculated Existing
CalculatedExisting
1
1 1
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
3
BID DOCUMENTS
FULLY SPRINKLERED
Services
Engineeringand FacilitiesManagement
U.S. Departmentof Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956
CONSULTANT
321 4 5 6 7 8 9 10
C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC
LEVEL 6 & 7 RENOVATIONSBuilding #1
#583-14-129
C:\U
sers
\FF
E-0
1\D
ocum
ents
\India
napolis
_E
lectr
ical_
harika.tum
mala
@ffe-s
erv
.com
.rvt
10/5
/2018 4
:11:0
5 P
M
EP-607b
PANEL SCHEDULE - SEVENTHFLOOR
10/05/18 JB HT
* LOCK-OUT / TAG-OUT EXISTING CIRCUIT, DISCONNECT AND WIRING REMOVE IN ITS ENTIRETY. DISCONNECT AND REMOVE ABANDONED CONDUIT. EXISTING TO REMAIN LOADS SHALL BE MAINTAINED, WHERE DISCREPANCIES OR UNACCOUNTED FORLOADS EXIST ON CIRCUITS TO BE DEMOLISHED, MAKE NOTE AND NOTIFY VA PROJECT MANAGEMENT OF THE ISSUE.** REFEED RELOCATED EQUIPMENT FROM SOURCE.
Notes:
Total Est. Demand Current: 65 A
Total Conn. Current: 65 A
Spare 8080 VA 100.00% 8080 VA Total Est. Demand: 23320 VA
Receptacle 180 VA 100.00% 180 VA Total Conn. Load: 23320 VA
Power 15060 VA 100.00% 15060 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 66 A 66 A 63 A
Total Load: 7860 VA 7860 VA 7600 VA
29 -- -- -- -- 4.1 kVA 30
27 -- -- -- -- 4.1 kVA 28
25 EWH-1 EWH-1 6th FLR MECH RM. ** 50 A 3 4.1 kVA 0.0 kVA -- -- -- -- 26
23 -- -- -- -- 0.4 kVA 0.0 kVA -- -- -- -- 24
21 -- -- -- -- 0.4 kVA 0.0 kVA 3 60 A SWITCHED OFF (EXISTING) -- 22
19 BP-2 20 A 3 0.4 kVA 0.4 kVA -- -- -- -- 20
17 -- PUMP 20 A 1 0.5 kVA 0.4 kVA -- -- -- -- 18
15 -- PUMP 20 A 1 0.5 kVA 0.4 kVA 3 20 A BP-1 16
13 -- PUMP 20 A 1 0.5 kVA 0.0 kVA 1 20 A Spare -- 14
11 -- PUMP 20 A 1 0.5 kVA 0.0 kVA 1 20 A Spare -- 12
9 -- RECPTS 11TH FLR (EXISTING) 20 A 1 1.1 kVA 0.0 kVA 1 40 A SPARE RADIO REP. (EXISTING) -- 10
7 -- RECPTS 11TH FLR (EXISTING) 20 A 1 1.1 kVA 1.1 kVA 1 20 A RECPTS C7121 (EXISTING) -- 8
5 -- ROTATING (ROOF) (EXISTING) 20 A 1 0.5 kVA 1.1 kVA 1 20 A RECPTS C7121 (EXISTING) -- 6
3 Spare RECPT FOR RCP-1 20 A 1 0.2 kVA 1.1 kVA 1 20 A RECPTS C7121 (EXISTING) -- 4
1 -- Spare 20 A 1 0.0 kVA 0.2 kVA 1 20 A PAR MACY ALARM C7138 (EXISTING) -- 2
CKT*
Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*
Demolished Circuit Description CKT
Notes: FEED THRU LUGS
Enclosure: Type 1
Mounting: Surface Wires: 4 Mains: 150 A
Supply From: Phases: 3 Mains Type: MCB
Location: ELECTR C-7059 Volts: 120/208 Wye A.I.C. Rating: 10,000 A
New Branch Panel: C7LE4
Calculated Existing
1
DRAWING NOTES:0
1. REPLACE EXISTING PANEL. RECONNECT EXISTINGFEEDER AND LOADS AS SHOWN.
Notes:
Total Est. Demand Current: 30 A
Total Conn. Current: 30 A
Total Est. Demand: 24540 VA
Total Conn. Load: 24540 VA
Spare 24540 VA 100.00% 24540 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 30 A 30 A 30 A
Total Load: 8180 VA 8180 VA 8180 VA
29 -- -- -- 0.4 kVA 0.0 kVA -- -- Space 30
27 -- -- -- 0.4 kVA 0.0 kVA -- -- Space 28
25 EF-37 20 A 3 0.4 kVA 0.0 kVA -- -- Space 26
23 -- -- -- 0.4 kVA 0.0 kVA -- -- Space 24
21 -- -- -- 0.4 kVA 0.0 kVA -- -- Space 22
19 EF-41 20 A 3 0.4 kVA 0.0 kVA -- -- Space 20
17 -- -- -- 0.0 kVA 0.0 kVA -- -- Space 18
15 -- -- -- 0.0 kVA 0.0 kVA -- -- Space 16
13 SPARE 20 A 3 0.0 kVA 0.0 kVA -- -- Space 14
11 -- -- -- 1.0 kVA 0.0 kVA -- -- Space 12
9 -- -- -- 1.0 kVA 0.0 kVA -- -- Space 10
7 NEW RF 20 A 3 1.0 kVA 0.0 kVA -- -- Space 8
5 -- -- -- 6.3 kVA 0.0 kVA -- -- Space 6
3 -- -- -- 6.3 kVA 0.0 kVA -- -- Space 4
1 NEW AHU-70 50 A 3 6.3 kVA 0.0 kVA -- -- Space 2
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
Notes: FEED THRU LUGS
Enclosure: Type 1
Mounting: Surface Wires: 3 Mains: 100 A
Supply From: C6HEX Phases: 3 Mains Type: MCB
Location: STAIR 2-7 Volts: 480 Delta A.I.C. Rating: 14,000 A
New Branch Panel: C7HEX
MOTOR LOAD, NEC ADJUSTED
10/05/18COVERING
ELECTRICAL DESIGN
10/05/18RESPONSIBLE
CHARGERevisions: Date:
AV SYMBOLS WITH ELECTRICAL REQUIREMENTS
WCSCLASSROOM SOUNDFIELD SYSTEM RECEIVER/AMPLIFIER/MIXER AND WALL OUTLET (44" MH UNLESS NOTEDOTHERWISE). TWO 1-GANG BOXES WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. SUBSCRIPT "W"INDICATES WALL MOUNTED ON SHELF. SOUNDFIELD SYSTEM, GROMMETED FACEPLATES AND CABLING PER DIV 27.
SH
SURFACE MOUNTED PAGING/INTERCOM SPEAKER (90" MH UNLESS NOTED OTHERWISE). SUBSCRIPT "H" INDICATESHANGING CEILING SPEAKER. 1-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. SPEAKER,INSTALLATION AND CABLING PER DIV 27.
MUSIC PLAY BACK SPEAKER (102" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. GROMMETED FACEPLATE, SPEAKER, INSTALLATION ADJACENT TO BOX AND WIRINGPER DIV 27.
SM
S HORN TYPE PAGING/INTERCOM SYSTEM SPEAKER (90" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUITTO ABOVE ACCESSIBLE CEILING PER DIV 26. GROMMETED FACEPLATE, SPEAKER, INSTALLATION AND WIRING PER DIV 27.
VPAGING/INTERCOM SYSTEM WALL MOUNTED SPEAKER VOLUME CONTROLLER (46" MH UNLESS NOTED OTHERWISE).1-GANG BOX AND 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. VOLUME CONTROLLER WITHFACEPLATE, INSTALLATION AND WIRING PER DIV 27.
M# X
MICROPHONE JACKPLATE (18" MH UNLESS NOTED OTHERWISE). "#"=NUMBER OF GANG, "X"=NUMBER OF JACKS IFOTHER THAN TWO (2). PROVIDE 0.75" CONDUIT FOR 1-GANG BOX OR 1" CONDUIT FOR 2-GANG AND LARGER BOX TOABOVE ACCESSIBLE CEILING PER DIV 26. JACKS, FACEPLATE AND CABLING PER DIV 27.
WC XWALL MOUNTED AV SYSTEM CONTROL INTERFACE. SUBSCRIPT "X" INDICATES TYPE. REFER TO SYSTEM DIAGRAMS.BACKBOX (46" MH UNLESS NOTED OTHERWISE) WITH 1" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26.CONTROLLER WITH CABLING PER DIV 27.
SR X LOCAL SOUND REINFORCEMENT SYSTEM SPEAKER. SUBSCRIPT "X" INDICATES TYPE. REFER TO SYSTEM DIAGRAMS.
SJ SPEAKER JACKPLATE (18" MH UNLESS NOTED OTHERWISE). 3-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLECEILING PER DIV 26.
WSF WALL MOUNTED SOUNDFIELD SYSTEM SPEAKER. 1-GANG BOX WITH 1" CONDUIT TO ABOVE CEILING PER DIV 26.SPEAKER AND CABLING PER DIV 27.
PRX
WALL MOUNTED PROJECTOR. BACKBOX WITH 1-1.25" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. PROJECTOR,MOUNT AND CABLING PER DIV 27. SUBSCRIPT "X" INDICATES CONFIGURATION TYPE, REFER TO FACEPLATE DETAILS.
WALL MOUNT ELECTRIC PROJECTION SCREEN. 1-GANG BOX WITH 1" CONDUIT TO ABOVE ACCESSIBLE CEILING PERDIV 26. SCREEN AND LOW VOLTAGE CONTROL PER DIV 27.PS E
CEILING MOUNT ELECTRIC PROJECTION SCREEN. 1-GANG BOX WITH 1" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV26. SCREEN AND LOW VOLTAGE CONTROL PER DIV 27.PS
E
LOCAL SOUND SYSTEM SENSING MICROPHONE. 1-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PERDIV 26. MICROPHONE WITH GROMMETED FACEPLATE, INSTALLATION AND WIRING PER DIV 27.SM
HM (x)HANGING MICROPHONE OUTLET. 1-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. SUBSCRIPT"X" INDICATES QUANTITY OF MICROPHONES IF MORE THAN ONE (1). MICROPHONE, JACK, FACEPLATE AND WIRING PER DIV 27.
MA MIC/AUX WALL MOUNTED INPUT (18" MH UNLESS NOTED OTHERWISE). 2-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. JACKS, FACEPLATE AND CABLING PER DIV 27.
MS MICROPHONE/SPEAKER WALL MOUNTED JACKPLATE (18" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75"CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. JACKS, FACEPLATE AND CABLING PER DIV 27.
ME MONITOR/EFFECTS WALL OUTLET (18" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. JACKS, FACEPLATE AND WIRING PER DIV 27.MULTI-PIN CONNECTOR WALL OUTLET (18" MH UNLESS NOTED OTHERWISE). NEMA BOX FOR 8"x8" PLATE WITH 2" CONDUITTO ABOVE ACCESSIBLE CEILING PER DIV 26. 8"x8" PLATE WITH CONNECTORS AND WIRING PER DIV 27.MP
REMOTE POWER SWITCH OUTLET (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. SWITCH, FACEPLATE AND WIRING PER DIV 27.
R
P PROGRAM SOURCE CABINET FOR PAGING/INTERCOM SYSTEM. TWO 1-GANG BOXES WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. GROMMETED FACEPLATES, CABINET, INSTALLATION AND WIRING PER DIV 27.
CAWALL MOUNTED CALL ANNUNCIATOR FOR PAGING/INTERCOM SYSTEM (90" MH UNLESS NOTED OTHERWISE). CUSTOMBACKBOX FURNISHED PER DIV 27, INSTALLED WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26.ANNUNCIATOR, INSTALLATION AND WIRING PER DIV 27.
CO WALL MOUNTED CALL ORIGINATION SWITCH FOR PAGING/INTERCOM SYSTEM (46" MH UNLESS NOTED OTHERWISE). 1-GANGBOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. CALL SWITCH, FACEPLATE AND WIRING PER DIV 27.
15W
SINGLE FACED WALL MOUNTED CLOCK (102” MH UNLESS NOTED OTHERWISE). 12” DIAMETER FACE ANALOG CLOCKUNLESS SUBSCRIPT “15” FOR 15” DIAMETER FACE ANALOG CLOCK OR “LED” FOR LED DIGITAL CLOCK. SUBSCRIPT “W”INDICATES WIREGUARD. 1-GANG BOX WITH 0.75” CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26.
15 DOUBLE FACED WALL MOUNTED CLOCK (102” MH UNLESS NOTED OTHERWISE). 12” DIAMETER FACE ANALOG CLOCKUNLESS SUBSCRIPT “15” FOR 15” DIAMETER FACE ANALOG CLOCK OR “LED” FOR LED DIGITAL CLOCK. 1-GANG BOX WITH0.75” CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26.ROOF MOUNTED ANTENNA. REFER TO ANTENNA MOUNTING DETAIL FOR MORE INFORMATION. SUBSCRIPT INDICATESTYPE.A
X
TECHNOLOGY SYMBOLS WITH ELEC. REQUIREMENTS
PWALL MOUNTED PHONE OUTLET (46" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT TO ABOVE ACCESSIBLECEILING PER DIV 26. JACKS, FACEPLATE AND CABLE PER DIV 27. REFER TO FACEPLATE DETAILS.
XR WALL MOUNTED AV OUTLET (84" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT PER DIV 26. REFER TO FACEPLATEDETAILS. JACKS, FACEPLATE AND CABLING PER DIV 27. SUBSCRIPT "X" INDICATES ALTERNATE CONFIGURATION.
XV WALL MOUNTED AV OUTLET (44" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT PER DIV 26. REFER TO FACEPLATEDETAILS. JACKS, FACEPLATE AND CABLING PER DIV 27. SUBSCRIPT "X" INDICATES ALTERNATE CONFIGURATION.
CONDUIT SLEEVE / FIRE RATED SLEEVE ASSEMBLY THRU WALL (1-2" SLEEVE UNLESS NOTED OTHERWISE) PER DIV 26.
J TELECOM BOX AND CONDUIT PER DIV 26, REFER TO PLANS.
D WALL MOUNTED VOICE/DATA OUTLET (18" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT(S) TO ABOVE CORRIDORCEILING PER DIV 26. JACKS, FACEPLATE AND CABLE PER DIV 27. REFER TO FACEPLATE DETAILS.
XIWALL MOUNTED AV OUTLET (18" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUITS TO ABOVE ACCESSIBLECEILING PER DIV 26. REFER TO FACEPLATE DETAILS. JACKS, FACEPLATE AND CABLING PER DIV 27. SUBSCRIPT "X"INDICATES ALTERNATE CONFIGURATION.
APWALL MOUNTED WIRELESS ACCESS POINT (96” MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. WAP AND CABLE PER DIV 27.
POKE-THRU PER DIV 26. # INDICATES TYPE, REFER TO POKE-THRU (PT) SCHEDULE. SUBSCRIPT "X" INDICATESTECHNOLOGY DEVICE(S), REFER TO TECHNOLOGY DETAILS.
#X
FLOOR BOX PER DIV 26. # INDICATES TYPE, REFER TO FLOOR BOX (FB) SCHEDULE. SUBSCRIPT "X" INDICATESTECHNOLOGY DEVICE(S), REFER TO TECHNOLOGY DETAILS.
#X
CUSTOM OUTLET IN SURFACE RACEWAY. SURFACE RACEWAY PER DIV 26. OUTLET JACKS, FACEPLATE AND CABLINGPER DIV 27.W
SECURITY SYMBOLS WITH ELECTRICAL REQUIREMENTS
CC 1 CCTV SYSTEM WALL MOUNTED CAMERA (REFER TO CAMERA SCHEDULE FOR MOUNTING HEIGHT AND CAMERASPECIFICATIONS). SUBSCRIPT "X" INDICATES ENTRY IN CAMERA SCHEDULE. 1-GANG BOX WITH 0.75" CONDUIT TOABOVE ACCESSIBLE CEILING PER DIV 26. CAMERA AND CABLING PER DIV 28.
PS1 LOCAL LOW VOLTAGE POWER SUPPLY FOR EXTERIOR CAMERA. SUBSCRIPT "X" INDICATES ASSOCIATED CAMERA.
120V POWER INTO LOCAL JUNCTION BOX ABOVE CEILING AND CONNECTION TO POWER SUPPLY PER DIV 26.POWER SUPPLY MOUNTED ABOVE CEILING AND LOW VOLTAGE WIRING TO LOCAL CAMERA PER DIV 28.
ICWALL MOUNTED INTERCOM DOOR STATION (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TOABOVE ACCESSIBLE CEILING PER DIV 26. INTERCOM AND CABLING PER DIV 28.
DMDOOR POSITION SWITCH WITH WIRING PER DIV 28. CONDUIT PATHWAYS FROM DOOR FRAME TO COMMON SMSJUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. PROVIDE ONE CONTACT FOR EACH LEAF IN MULTI-DOOROPENINGS. REFER TO SECURITY ROUGH-IN DETAILS.
ELELECTRONIC DOOR LOCK AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING PER DIV 28. CONDUIT PATHWAYSFROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. REFER TO SECURITYROUGH-IN DETAILS.
EMELECTRONIC MAG LOCK AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING PER DIV 28. CONDUIT PATHWAYSFROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. REFER TO SECURITYROUGH-IN DETAILS.
ESELECTRONIC STRIKE AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING PER DIV 28. CONDUIT PATHWAYS FROMDOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. REFER TO SECURITY ROUGH-IN DETAILS.
LB
RXREQUEST TO EXIT SWITCH IN DOOR HARDWARE BY OTHERS. LOW VOLTAGE WIRING PER DIV 28. CONDUIT PATHWAYSFROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. REFER TO SECURITYROUGH-IN DETAILS.
HDHANDICAP DOOR OPERATOR MOTOR ASSEMBLY BY OTHERS. 120V POWER CONNECTION AND CONDUIT FROM DOORFRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. LOW VOLTAGE WIRING ANDINTERFACE WITH SMS AND DOOR ACTUATOR BUTTONS PER DIV 28. REFER TO SECURITY ROUGH-IN DETAILS.
HA
WALL/PEDESTAL MOUNT HANDICAP DOOR ACTUATOR BUTTON, FURNISHED BY OTHERS. BOX AS REQUIRED BYSYSTEM MANUFACTURER WITH INSTALLATION AND CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLECEILING PER DIV 26. ALL LOW VOLTAGE WIRING AND INTERFACE WITH SMS AND DOOR MOTOR PER DIV 28. REFERTO SECURITY ROUGH-IN DETAILS.
HOFA
WALL/FLOOR MOUNTED ELECTROMAGNETIC DOOR HOLD OPEN WITH POWER SUPPLY INSTALLED BY OTHERS. 120VPOWER AND CONNECTION, BOX AS REQUIRED BY MANUFACTURER AND CONDUIT TO COMMON SMS JUNCTION BOX ABOVEACCESSIBLE CEILING PER DIV 26. LOW VOLTAGE WIRING FROM POWER SUPPLY TO HOLD OPEN AND INTERFACE WITHSMS PER DIV 28. SUBSCRIPT "FA" INDICATES DEVICES POWERED FROM FIRE ALARM SYSTEM AND INTERFACE FROM SMSTO FIRE ALARM SYSTEM REQUIRED FOR DOOR RELEASE PER DIV 28. REFER TO SECURITY ROUGH-IN DETAILS.
CRWALL MOUNTED PROXIMITY CARD READER (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH CONDUIT TOCOMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. CARD READER AND CABLING PER DIV 28.REFER TO SECURITY ROUGH-IN DETAILS.
CR EL
ELEVATOR CAB MOUNTED CARD READER. READER TO BE INSTALLED IN ELEVATOR CAB AS COORDINATED WITHELEVATOR CONTRACTOR. WIRING FROM CAB THRU TRAVELING CABLE TO ELEVATOR CONTROLLER IN ELEVATORMACHINE ROOM AND INTERFACE WITH ELEVATOR CONTROLLER AND SMS PER DIV 28, COORDINATE WITH ELEVATORCONTRACTOR. REFER TO SECURITY ROUGH-IN DETAILS.
KCWALL MOUNTED COMBINATION KEYPAD/CARDREADER (46" MH UNLESS NOTED OTHERWISE). 2-GANG BOX WITH 0.75"CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. DEVICE AND CABLING PER DIV 28.
KWALL MOUNTED SECURITY KEYPAD ENTRY STATION (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75"CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. KEYPAD AND CABLING PER DIV 28.
MD WALL MOUNTED MOTION DETECTOR (90" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. MOTION DETECTOR, WALL MOUNT HARDWARE, AND CABLING PER DIV 28.
PP WWALL MOUNTED PANIC/DURESS BUTTON (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TOABOVE ACCESSIBLE CEILING PER DIV 26. BUTTON AND CABLING PER DIV 28.
XWALL MOUNTED SECURITY SYSTEM WIRING OUTLET MOUNTED BELOW COUNTER TOP. 2-GANG BOX WITH 2-1"CONDUITS TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. GROMMETED FACEPLATE ANDSECURITY SYSTEM CABLING PER DIV 28.
CMWALL MOUNTED MONITOR OUTLET FOR CCTV SYSTEM (84" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 1"CONDUIT TO ABOVE CORRIDOR CEILING PER DIV 26. JACK, FACEPLATE AND CABLING PER DIV 28.
MIC CEILING MOUNTED SECURITY/CCTV SYSTEM AUDIO MICROPHONE. 1-GANG BOX MOUNTED IN CEILING PER DIV 26.MICROPHONE AND CABLING PER DIV 28.
BRWALL MOUNTED BIOMETRIC READER (46" MH UNLESS NOTED OTHERWISE). 2-GANG BOX WITH 0.75" CONDUIT TOCOMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. READER AND CABLING PER DIV 28. REFERTO SECURITY ROUGH-IN DETAILS.
X
X
MD
PB WWALL MOUNTED PUSH BUTTON FOR LOCAL ELECTRONIC DOOR RELEASE (46" MH UNLESS NOTED OTHERWISE). 1-GANGBOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. BUTTON AND CABLING PER DIV 28.
ELECTRONIC LATCH BOLT MONITORING. HARDWARE AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING PER DIV28. CONDUIT PATHWAYS FROM DOOR FRAME TO COMMON SECURITY JUNCTION BOX ABOVE CEILING PER DIV 26.REFER TO SECURITY ROUGH-IN DETAILS.CEILING MOUNTED MOTION DETECTOR. 1-GANG BOX MOUNTED IN CEILING PER DIV 26. DETECTOR AND CABLINGPER DIV 28.
DC
LOCAL IP BASED 2-DOOR ACCESS CONTROL PANEL SERVING LOCAL CARD READER/SECURITY CONTROLLED DOORS.LOCATE ABOVE ADJACENT ACCESSIBLE CEILING. PROVIDE DATA DROP IN 0.75" CONDUIT TO LOCAL DATA CLOSET.EXTEND 1" CONDUIT WITH DOOR SECURITY WIRING TO LOCAL SECURITY SYSTEM JUNCTION BOX. REFER TO SECURITYROUGH-IN DETAILS.
JB
SECURITY SYSTEM JUNCTION BOX TO BE LOCATED ABOVE ACCESSIBLE CEILING (MIN 6"X6"X4"). ROUTE LOCAL DOORSECURITY WIRING CONDUITS/RACEWAYS TO JUNCTION BOX. EXTEND 1" CONDUIT WITH DOOR SECURITY WIRING TOLOCAL 2-DOOR CONTROL PANEL/REMOTE DOOR CONTROL PANEL AS INDICATED ON DRAWINGS. REFER TO SECURITYROUGH-IN DETAILS.
PL
SITE POLE FOR MOUNTING SECURITY CAMERAS (REFER TO SPECIFICATIONS FOR SIZE/TYPE). PROVIDE POLE WITHCONCRETE BASE AS INDICATED ON PLANS. EXTEND AND CONNECT TO SITE CONDUIT SYSTEM AS INDICATED ONPLANS. PROVIDE NEMA 3R JUNCTION BOX AT BASE OF POLE FOR CAMERA EQUIPMENT (120V POWER SUPPLY, FIBERCONVERTERS, ETC.). REFER TO SECURITY ROUGH-IN DETAILS.
ABBREVIATIONSAAP - AREA ALARM PANEL - MEDICAL GASACC - ACCESSADJ - ADJUSTABLEAF - ARC FAULT CIRCUIT INTERRUPTERAFCI - ARC FAULT CIRCUIT INTERRUPTERAFF - ABOVE FINISHED FLOOR TO BOTTOM OF ITEMAFG - ABOVE FINISHED GRADE TO BOTTOM OF ITEMALT - ALTERNATEAP - ACCESS PANELAPPROX - APPROXIMATEARCH - ARCHITECT OR ARCHITECTURALASSY - ASSEMBLYATS - AUTOMATIC TRANSFER SWITCH
BLDG - BUILDINGBOE - BOTTOM OF EQUIPMENTBOT - BOTTOMBTWN - BETWEEN
CFCI - CONTRACTOR FURNISHED CONTRACTOR INSTALLEDCKT - CIRCUITCLG - CEILINGCMU - CONCRETE MASONRY UNITCONN - CONNECT OR CONNECTIONCONTR - CONTRACTORCOR - CONTRACTING OFFICER'S REPRESENTATIVECORR - CORRIDORCTR - CENTER
D - DEPTHDET - DETAILDIA - DIAMETERDIM - DIMENSIONDIV - DIVISIONDN - DOWNDWG - DRAWING
EA - EACHEC - ELECTRICAL CONTRACTOR (DIVISION 26)EJ - EXPANSION JOINTELEC - ELECTRICALELEV - ELEVATION OR ELEVATOREM - EMERGENCYEQ - EQUALEQS - EQUIPMENT SUPPLIEREQUIP - EQUIPMENTETR - EXISTING TO REMAINEX - EXISTINGEXP - EXPANSIONEXT - EXTERIOR
FCE - FIRE CONTROL EQUIPMENTFF - FINISHED FLOOR ELEVATIONFLR - FLOORFSC - FIRE SUPPRESSION CONTRACTOR (DIVISION 21)FT - FEETFTG - FOOTING
GC - GENERAL CONTRACTORGF - GROUND FAULT CIRCUIT INTERRUPTERGFCI - GROUND FAULT CIRCUIT INTERRUPTER OR GOVERNMENT
FURNISHED CONTRACTOR INSTALLEDGFFT - GROUND FAULT FEED THRU
HC - HVAC CONTRACTOR (DIVISION 23)HP - HORSE POWER OR HIGH POINTHVAC - HEATING, VENTILATING, AND AIR CONDITIONING
ID - INSIDE DIAMETERIN - INCHES
KEC - KITCHEN EQUIPMENT CONTRACTOR
L - LENGTHLBS - POUNDS
MAP - MASTER ALARM PANEL (MEDICAL GAS)MAX - MAXIMUMMEZZ - MEZZANINEMFR - MANUFACTURERMH - MANHOLE OR MOUNTING HEIGHT TO CENTER LINE OF ITEMMIN - MINIMUM OR MINUTEMISC - MISCELLANEOUSMTD - MOUNTEDMTG - MOUNTING
NIC - NOT IN CONTRACTNOM - NOMINALNTS - NOT TO SCALE
OD - OUTSIDE DIAMETEROFCI - OWNER FURNISHED CONTRACTOR INSTALLEDOFOI - OWNER FURNISHED OWNER INSTALLED
PC - PLUMBING CONTRACTOR (DIVISION 22)PLBG - PLUMBING
RAD - RADIUSREC - RECESSEDREQD - REQUIREDRI - ROUGH-IN
S - SURFACE MOUNTEDSC - SECURITY CONTRACTORSCH - SCHEDULESHT - SHEETSMS - SECURITY MANAGEMENT SYSTEMSPEC - SPECIFICATIONSSQ - SQUARESS - STAINLESS STEELSTD - STANDARDSTRUC - STRUCTURAL OR STRUCTURESUC - SITE UTILITY CONTRACTOR
TC - TECHNOLOGY CONTRACTORTEMP - TEMPERATURETOE - TOP OF EQUIPMENTTYP - TYPICAL
UNO - UNLESS NOTED OTHERWISE
VFD - VARIABLE FREQUENCY DRIVEVOL - VOLUME
W/ - WITHW/0 - WITHOUTWP - WEATHERPROOF
ZVC - ZONE VALVE CABINET
3
3
1
E2
B
E2DETAIL: B = DETAIL DESIGNATION
E2 = SHEET WHERE DETAIL IS LOCATED
SECTION: 1 = SECTION DESIGNATION E2 = SHEET WHERE DETAIL IS LOCATED
PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH IT IS SHOWN.
DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.
GENERAL FLOOR PLAN NOTES
WIRE & CONDUIT IN WALL OR ABOVE CEILING.
WIRE & CONDUIT IN OR BELOW SLAB OR GRADE.
CABLE TRAY, 12" x 4" DEEP UNLESS NOTED OTHERWISE.
CONDUIT FOR DATA CIRCUITRY.DAT
WIRE & CONDUIT FOR FIRE ALARM CIRCUITRY.FA
WIRE & CONDUIT FOR NURSE CALL CIRCUITRY.NC
EXISTING WIRE & CONDUIT TO REMAIN.E
CONDUIT TO BE REMOVED.
WIRE & CONDUIT FOR NIGHT LIGHT CIRCUITRY.NL
CONDUIT FOR PHONE CIRCUITRY.PHO
WIRE & CONDUIT FOR SECURITY SYSTEM CIRCUITRY.SEC
WIRE RUN IN SURFACE WIREWAY.W
CABLE MANAGEMENT SYSTEM PATHWAY.CM
WIRE & CONDUIT FOR EMERGENCY CIRCUITRY.EM
WIRE & CONDUIT FOR SOUND SYSTEM CIRCUITRY.S
WIRE & CONDUIT FOR INTERCOM SYSTEM CIRCUITRY.I
WIRE & CONDUIT FOR TELEVISION SYSTEM CIRCUITRY.TV
FIRE ALARM SYMBOLS
FIRE ALARM BELL & SIGNAL LIGHT (80" AFF). # WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOTSHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS.
FIRE ALARM CHIME & SIGNAL LIGHT (80" AFF). # WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOTSHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS.
FIRE ALARM HORN & SIGNAL LIGHT (80" AFF). # WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOTSHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS.
FIRE ALARM SIGNAL LIGHT (80" AFF). # WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN,THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS.
15F
15F
15F
15
F
SF
CEILING MOUNTED FIRE ALARM SPEAKER.
CEILING MOUNTED FIRE ALARM SPEAKER & SIGNAL LIGHT. # WHEN SHOWN INDICATES CANDELA RATING OF STROBE.WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHERLOCATIONS.
FIRE ALARM MANUAL STATION (46" MH UNLESS NOTED OTHERWISE). SUBSCRIPT "K" INDICATES KEY OPERATED.
CEILING MOUNTED SMOKE DETECTOR.
CEILING MOUNTED HEAT DETECTOR.
DUCT MOUNTED SMOKE DETECTOR. SUBSCRIPT "S" INDICATES SUPPLY. SUBSCRIPT "R" INDICATES RETURN.
DUCT MOUNTED HEAT DETECTOR. SUBSCRIPT "S" INDICATES SUPPLY. SUBSCRIPT "R" INDICATES RETURN.
ELECTRIC RELEASE DOOR CLOSER.
ELECTRO-MAGNETIC DOOR HOLDER.
WATER FLOW SWITCH.
VALVE SUPERVISORY SWITCH.
CEILING MOUNTED REMOTE TEST STATION AND ALARM INDICATOR LIGHT FOR DUCT DETECTOR. SUBSCRIPT "W" INDICATESWALL MOUNTED.
SMOKE DAMPER.
FIRE FIGHTER'S TELEPHONE (60" MH UNLESS NOTED OTHERWISE).
KF
S
H
C
D
FS
V
RW
SD
FT
PRESSURE SWITCH.
ADDRESSABLE MODULE. SUBSCRIPT "I" INDICATES INPUT. SUBSCRIPT "C" INDICATES CONTROL.
POST INDICATOR VALVE.
KNOX BOX (46" MH UNLESS NOTED OTHERWISE). SUBSCRIPT "S" INDICATES SUPERVISED UNIT.
PS
AMC/I
PIV
KS
H
SS/R
S/R
S 15F
FIRE ALARM BELL (80" AFF UNLESS NOTED OTHERWISE). SUBSCRIPT "W" INDICATES EXTERIOR WEATHERPROOF UNIT.FW
BEAM DETECTOR. SUBSCRIPT "T" INDICATES TRANSMITTER FUNCTION. SUBSCRIPT "R" INDICATES RECEIVER FUNCTION.BT/R
AIR SAMPLING SMOKE DETECTOR SAMPLING PORT.A
COMBINATION FIRE ALARM AND MASS NOTIFICATION CONTROL PANEL.FMCP
FIRE ALARM AND MASS NOTIFICATION COMBINATION SPEAKER & SIGNAL LIGHT (80" AFF). # WHEN SHOWN INDICATESCANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 75CANDELA FOR ALL OTHER LOCATIONS. DEVICE SHALL HAVE RED BODY MARKED "ALERT" IN WHITE LETTERING WITH CLEARLENS.
15F
LOCAL OPERATOR'S CONSOLE.LOC
AUDIO CONTROL UNIT.ACU
15
F
CEILING MOUNTED FIRE ALARM AND MASS NOTIFICATION COMBINATION SPEAKER & SIGNAL LIGHT. # WHEN SHOWNINDICATES CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA INCORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS. DEVICE SHALL HAVE RED BODY MARKED "ALERT" INWHITE LETTERING AND HAVE CLEAR LENS.
S 15F
FIRE ALARM AND MASS NOTIFICATION SIGNAL LIGHT (80" AFF). # WHEN SHOWN INDICATES CANDELA RATING OF STROBE.WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 75 CANDELA FOR ALL OTHERLOCATIONS. DEVICE SHALL HAVE RED BODY MARKED "ALERT" IN WHITE LETTERING WITH CLEAR LENS.
SURFACE MOUNTED FIRE ALARM SPEAKER (80" AFF). SUBSCRIPT "R" INDICATES RECESSED MOUNTING.SR
AV SYMBOLS
42 FLAT PANEL DISPLAY WITH WALL MOUNTING HARDWARE (84" MH UNLESS NOTED OTHERWISE). # INDICATES NOMINALSCREEN DIAGONAL SIZE.
AV AV SYSTEM CONTROLLER.
DV W BLU-RAY/DVD PLAYER WITH CONNECTION TO LOCAL OUTLET. SUBSCRIPT "W" INDICATES WALL MOUNTED ON SHELF.
SBW
VIDEO ON DEMAND SET TOP BOX. SUBSCRIPT "W" INDICATES WALL MOUNTED ON SHELF.
PC LOCAL RS-232/IP PROJECTOR CONTROLLER.
PS WALL MOUNTED MANUAL PROJECTION SCREEN.
PS CEILING MOUNTED MANUAL PROJECTION SCREEN.
SF SOUNDFIELD SYSTEM CEILING SPEAKER.
IR SOUNDFIELD SYSTEM CEILING IR SENSOR. LOCATION SHOWN FOR ESTIMATING PURPOSES ONLY. EACH SYMBOLREPRESENTS A QUANTITY OF TWO (2) SENSORS TO BE LOCATED FOR OPTIMUM DROP-FREE RECEPTION.
SC CEILING MOUNTED PAGING/INTERCOM SYSTEM SPEAKER.
15W
SINGLE FACED, WALL MOUNTED CLOCK (102" MH UNLESS NOTED OTHERWISE). 12" DIAMETER FACE UNLESSSUBSCRIPT "15" FOR 15" DIAMETER FACE. SUBSCRIPT "W" INDICATES WIREGUARD.
15 DOUBLE FACED, WALL MOUNTED CLOCK (102" MH UNLESS NOTED OTHERWISE). 12" DIAMETER FACE UNLESSSUBSCRIPT "15" FOR 15" DIAMETER FACE.
INTERACTIVE WHITE BOARD.IW
PRX
CEILING MOUNTED PROJECTOR. SUBSCRIPT "X" INDICATES CONFIGURATION TYPE, REFER TO FACEPLATE DETAILS.
AR AREA OF REFUGE / AREA OF RESCUE REMOTE CALL STATION (46" MH UNLESS NOTED OTHERWISE).
AP AREA OF REFUGE / AREA OF RESCUE POWER SUPPLY WITHIN A WALL MOUNTED ENCLOSURE.
AM W
AE AREA OF REFUGE / AREA OF RESCUE EXPANSION SWITCH WITHIN A WALL MOUNTED ENCLSURE.
AREA OF REFUGE / AREA OF RESCUE MAIN CONTROL PANEL. "W" INDICATES WALL MOUNTED WITHIN AN ENCLOSURE,OTHERWISE DESKTOP UNIT.
NURSE CALL SYMBOLS
NURSE CALL DESK MOUNTED MASTER CONTROL STATION (OUTLET AT 18" MH UNLESS NOTED OTHERWISE). SUBSCRIPT"W" INDICATES WALL MOUNT (46" MH UNLESS NOTED OTHERWISE). RAULAND RESPONDER MODEL #351205
NURSE CALL CONTROL PANEL.
NURSE CALL STAFF STATION (46" MH UNLESS NOTED OTHERWISE).
NURSE CALL DUTY STATION (46" MH UNLESS NOTED OTHERWISE). RAULAND RESPONDER MODEL # 353100
EMERGENCY NURSE CALL STATION WITH PULL CORD FOR PATIENT USE (46” MH AND TO SIDE AND WITHIN 12” FROMFRONT OF TOILET BOWL IN TOILET ROOMS, 66” MH IN SHOWERS AND WET AREAS, 46” MH UNLESS NOTED OTHERWISE INALL OTHER AREAS).
PATIENT NURSE CALL UTILITY CONSOLE (46" MH UNLESS NOTED OTHERWISE).
PATIENT NURSE CALL STATION (ONE OR TWO CORDS AS INDICATED, 46" MH UNLESS NOTED OTHERWISE).RAULAND RESPONDER #354001
CEILING MOUNTED NURSE CALL DOME LIGHT.
WALL MOUNTED NURSE CALL DOME LIGHT (90" MH UNLESS NOTED OTHERWISE). RAULAND RESPONDER MODEL #352010
CEILING MOUNTED COMBINATION DOME LIGHT AND BUZZER.
CEILING MOUNTED NURSE CALL ZONE LIGHT.
NURSE CALL EMERGENCY BUTTON (46" MH UNLESS NOTED OTHERWISE).
EMERGENCY CODE BLUE BUTTON (46" MH UNLESS NOTED OTHERWISE).
N
N
NB
NZ
NC
NS
ND
N
WNM
NT
NE
NB
NCCP
NURSE CALL MULTI-PIN CATV JACK (84" AFF UNLESS NOTED OTHERWISE).
NURSE CALL STAFF PRESENCE STATION (60" AFF UNLESS NOTED OTHERWISE).
CNS
PNS
NOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT TO MODIFICATIONS ON OTHER DRAWINGS.
ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT NECESSARILY BE USED ON THIS
PROJECT.
GENERAL NOTESA. ALL FINAL LOCATIONS AND ARRANGEMENTS OF LIGHTING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL
REFLECTED CEILING PLAN.
B. LIGHTING FIXTURES WITH MORE THAN TWO LAMPS SHALL HAVE TWO OUTER LAMPS CONTROLLED WITH ONE SWITCHAND INNER LAMP(S) CONTROLLED BY A SECOND SWITCH.
C. EACH BRANCH CIRCUIT HOMERUN SHALL HAVE NO MORE THAN THREE CIRCUITS. EACH BRANCH CIRCUIT HOMERUN SHALLHAVE A SEPARATE GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR.
D. MULTI-GANG BACKBOXES FOR DIFFERENT VOLTAGES AND TYPES OF EMERGENCY AND NORMAL BRANCH WIRINGDEVICES SHALL HAVE DIVIDERS BETWEEN DEVICES.
GENERAL NOTES - DEMOLITIONA. FOR EXISTING EQUIPMENT, SUCH AS LIGHTING FIXTURES, WIRING DEVICES, CONDUITS, ETC., SHOWN ON PLANS
TO BE REMOVED, COMPLETELY CUT/CAP CONDUITS AT THE AREA OF WORK PERIMETER AND REMOVE CONDUITWITHIN THE WORK AREA, DISCONNECT WIRING AT THE OVERCURRENT PROTECTIVE DEVICE AND REMOVE WIRINGCOMPLETELY FROM THE ABANDONED CONDUITS.
B. DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE OVERCURRENT PROTECTIVE DEVICE. COMPLETELYREMOVE ALL ABANDONED WIRING.
C. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND CONDUCTORS PASSING THROUGH RENOVATEDAREAS AND SERVICING UNDISTURBED AREAS.
EDCELECTRONIC DOOR LOCK, INSTALLATION AND WIRING BY OTHERS. PROVIDE CONDUIT PATHWAYS FROM DOORFRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING.
PROJECT NO.
10/05/18COVERINGTECHNOLOGY DESIGN
C:\B
IM\M
odel
\201
7-91
021-
Tec
hnol
ogy-
Cen
tral
_RLC
ondy
.rvt
10/5
/201
8 10
:49:
46 A
M
2017-91021
BID DOCUMENTS - OCTOBER 05, 2018
10/05/18RESPONSIBLE CHARGE
AP
D4D
DD5
DD3
DD3
AP
D4D
DD2 SC
D4 D D4 D
DD2
D2 D D2 D
DD2
P
V
F
APD2D
DD2
DD4
SC
AP
F
D4 D
F
F
SC
CC
CCF
CR
SC
AP CC SC
F
AP SC
DD4
DD4
DD4
AP
DD2
DD2
D4D
DD4
D4 D
APD
D4
D4 D
DD4
D4 D
DD4
D5D
SC
DD4
D4D
AP
D4 D
F
AP
DD4
AP
D4 D
D4D
D4 DAP
VF
D5D
DD5
D4D
D4 D
CR
CC
AP
AP
AP
D2DD2D
D2 D
D2D
D2 D
D2D
D2 D
D2D
D2D
DD2
DD2
DD2
DD2
DD2
D2 D
DD2
DD2
DD2
DD2
D2D
DD2
D4 D
ABANDONEDWALL MOUNTCABINET
1
1
1
1
2
3
3
3
2
3
3
4
3
3
2
33
RESEARCHPULMONARYC-6021
TOILETC-6023
RESEARCHPULMONARYC-6024
RESEARCHPULMONARYC-6025
RESEARCHPULMONARYC-6027
RESEARCHPULMONARYC-6028
RESEARCHPULMONARYC-6030
RESEARCHPULMONARYC-6032
RESEARCHPULMONARYC-6033
STORAGEC-6034
UNKNOWNC-6010
UNKNOWNC-6009
CHIEF SOCIALWORKERC-6008
ASSISTANTCHIEF SOCIALWORKERC-6007RESEARCH
PULMONARYC-6006
RESEARCHC-6004
TLT RMC-6005
UNKNOWNC-6011UNKNOWN
C-6012SPS CLEAN/PREPC-6013
SPS DECONC-6014
SPSCHANGINGC-6015
ENV.SERVICESC-6017
TOILETC-6016
STORAGEC-6020
SOILEDUTILITYC-6018MECH. RM
C-6019
MECH. ROOMC-6036
CORRIDORC6-23
RESEARCHPULMONARYC-6003
OFFICEC-6041
RESEARCHPULMONARYC-6002
RESEARCHPULMONARYC-6001
PULMONARYC-6162
RESEARCHPULMONARYC-6001
STAIRS1-6
SEIU LOCAL#551C-6058
SEIU LOCAL#551C-6059
SEIU LOCAL#551C-6060
SEIU LOCAL#551C-6061
TOILETC-6062
CORRIDORC6-22
MHICM OFFICEC-6110
FREIGHTELEVATORLOBBYC6-26
TEL. RM.85
TOILETC-6026
TOILETC-6029
TOILETC-6022
5
3
3
3
PROJECT NO.
10/05/18COVERINGTECHNOLOGY DESIGN
C:\B
IM\M
odel
\201
7-91
021-
Tec
hnol
ogy-
Cen
tral
_RLC
ondy
.rvt
10/5
/201
8 10
:49:
41 A
M
2017-91021
1/8" = 1'-0"TD-106
1 LEVEL 6 DEMOLITION PLAN
1. DISCONNECT EXISTING VIDEO SURVEILLANCE CAMERAS. PULL BACK DATA CABLE TOTHE NON-RENOVATION AREA NEAR THE SIGNALS CLOSET. RE-INSTALL DATA CABLEAFTER THE RENOVATION IS COMPLETED. SEE SHEET T2.16 FOR LOCATIONS.
2. GUEST WIRELESS ACCESS POINT (AP). REMOVE AND STORE IN A SECURE LOCATION.RE-INSTALL AS INDICATED ON SHEET TA-106 AND TA-107.
3. VA WIRELESS ACCESS POINT (AP). REMOVE AND STORE IN A SECURE LOCATION. RE-INSTALL AS INDICATED ON SHEET TA-106 AND TA-107.
4. DISCONNECT, REMOVE AND DISPOSE OF PROPERLY THE OLD NURSE CALL PANEL, THESCRAMBLE PAD PANEL AND THE MAGLOCK PANEL IN ROOM C6004.
5. EXISTING CARD READER TO REMAIN. PROVIDE PROTECTIVE COVER DURINGRENOVATIONS.
GENERAL DEMO NOTES:
BID DOCUMENTS - OCTOBER 05, 2018
10/05/18RESPONSIBLE CHARGE
AP
D5D
D5 D
DD5
DD5
D5D
AP
DD5
D5 D
D5 D
D5D AP
D5 D
D5 D
D5D
D4D
SC
F
CC
CR
AP
DD5
D2 D
CR
F
AP
AP
SC
D5D
D4 D
DD4
D5D
APD
D5
D5D
D4 D D4 D
DD5
DD5
APD
D5 DD5
DD5
P
D5D
D5 D
AP
AP
SCSC
APAP
SC
F
DD5
AP
SC
DD5
DD2
DD5
D5DD5D
D5 D
F
D5D
DD5
AP
DD5
AP
DD2
D4D
D2 D
AP
DD2
F
SC
DD5
AP
DD4
D5D
D5 D
D5D
AP
D5 D
DD5
SC
AP
CR
D5D
AP
D5 D
D5D
D5 D
F
CC
AP
DD5
DD5
F
AP
D5D
F
DD5
D4 D
CR
AP
AP
AP
D2 D
D5 D
P
D2 D
D5D
DD5
D5 D
DD5
D2 D
DD2
DD5
D2 DD2 DD2D
DD4
AP
AP
SC SC
AP
2
3
1
3
3
3
33 3
23
3
3
32
4
3
3
3
3
2
3 3
SECRETARYC-7033
STOR.C-7035
STAFFTOILETC-7039
STAFFTOILETC-7037
SUPERVISORYMEDICALSUPPORTASSISTANTC-7038
CHIEF PCSPROCEDURALC-7040
PROGRAMANALYSTC-7041
CHIEFMEDICALSERVICEC-7043
MEDICALSERVICEC-7042
CORRIDORC7-11
BUSINESSMANAGERC-7044
STORAGEC-7045
ASST. CHIEFMEDICALSERVICEC-7046
CHIEF PCSMEDICINE/ CMC-7047
CONFERENCEROOMC-7048
MECH RMC-7049
MAILROOM/BREAKROOMC-7051
STOR.C-7050
STAIRS2-7
FIRE EQUIP.C-7052
KITCHENC-7006
STAFF TOILETC-7005
STOR.C-7009
STOR.C-7007
PROGRAMSUPPORTASSISTANTSC-7008
STAFF TOILETC-7010
STOR.82
STOR.81
CHIEFHOSPITALISTC-7012
PIPE CHASEC-7011
STAFFTOILETC-7013
STAFFTOILETC-7015 CHIEF
GENERALINTERNALMEDICINEC-7016
STOR.C-7014
CHIEFGERIATRICSC-7018STAFF
TOILETC-7019
STAFFTOILETC-7023
STOR.C-7021
PIPE CHASEC-7020
PHYSICIANC-7022
PIPE CHASEC-7024
PHYSICIANC-7025
CORRIDORC7-10
CHIEFHEMATOLOGYC-7026
PIPE CHASEC-7027
CHIEFONCOLOGYC-7028
EMSC-7029
SOILEDUTILITYC-7030MECH. ROOM
C-7031
STOR.C-7032 STAFF
TOILETC-7034
CORRIDORC7-9
CONFERENCEROOMC-7179
CHIEFNEPHROLOGYC-7002
NEPHROLOGYC-7001
PHYSICIANC-7003
PHYSICIANC-7004
STAFFTOILETC-7056
CHIEFPULMONARYC-7057
CHIEF GIC-7058
CORRIDORC7-8
STAIRS1-7
FIRE EQUIP.C-7076 MECH. ROOM
C-7075
RESIDENTSC-7077
PHYSICIANC-7079
CORRIDORC7-7
TELE. ROOM48
PHARMACYSTORAGEC-7122
MED. SERV.ADIM.C-7123
PHARMACYSTORAGEC-7124
CLIN. DIETC-7138
FREIGHTELEVATORSLOBBYC7-12
VENDINGC-7139
3
3
3
5
C-9015CLOSET
C-9016CLOSET
C-9014
PROCESSING&
RECORDS
C-9013CLOSET
58CLOSET
57CLOSET
C-9010
HRSPECIALIZINGRECRUITMENT
&PLACEMENT
C-9027Room
C-9031CLOSET
C-9028
EMPLOYEE/LABORRELATIONS
C-9017
MEETINGROOM
C-9007BREAKROOM
C-9009STORAGE
C-9008STORAGE
C-9002
PERS.MANAG.
SPECIALIST
C-9005
PERS.MANAG.
SPECIALIST
C-9004
PERS.MANAG.
SPECIALIST
C-9003
PERS.MANAG.
SPECIALIST
C-9033Room
C-9037CLOSET
C-9038CLOSET
C-9032
MED.STAFF &NURSE
CREDENTIALING
C-9052
FIREEQUIPMENT
C-9051
ELEC.ROOM
C-9036
EMPLOYMENTINFORMATION
C9-3LOBBY
C-9050CLOSET
C-9039ENG.
C9-4LOBBY
C9-5CORRIDOR
C-9030
HRSPECIALIST
CLASSIFICATION
C-9035
HUMANRESOURCES
59
HUMANRESOURCES
C-9006
HUMANRESOURCES
6
6
7
6
PROJECT NO.
10/05/18COVERINGTECHNOLOGY DESIGN
C:\B
IM\M
odel
\201
7-91
021-
Tec
hnol
ogy-
Cen
tral
_RLC
ondy
.rvt
10/5
/201
8 10
:49:
46 A
M
2017-91021
1/8" = 1'-0"TD-107
1 LEVEL 7 DEMOLITION PLAN
GENERAL DEMO NOTES:1. DISCONNECT EXISTING VIDEO SURVEILLANCE CAMERAS. PULL BACK DATA CABLE TO THE
NON-RENOVATION AREA NEAR THE SIGNALS CLOSET. RE-INSTALL DATA CABLE AFTER THERENOVATION IS COMPLETED. SEE SHEET TA-107 FOR LOCATIONS.
2. GUEST WIRELESS ACCESS POINT (AP). REMOVE AND STORE IN A SECURE LOCATION. RE-INSTALL AS INDICATED ON SHEET TA-106 AND TA-107.
3. VA WIRELESS ACCESS POINT (AP). REMOVE AND STORE IN A SECURE LOCATION. RE-INSTALL AS INDICATED ON SHEET TA-106 AND TA-107.
4. REMOVE EXISTINGVIDEO SURVEILLANCE CAMERA AND TURN OVER TO THE OWNER. PULLBACK DATA CABLE TO THE NON RENOVATION AREA NEAR SIGNALS CLOSET. STORE CABLEAND LABEL FOR FUTURE USE.
5. EXISTING CARD READER TO REMAIN. PROVIDE PROTECTIVE COVER DURINGRENOVATIONS.
6. DISCONNECT EXISTING AP'S, SECURE AND STORE. COIL AND SECURE CURRENT DATACABLE TO KEEP FROM BEING DAMAGED DURING RENOVATION.
7. DISCONNECT EXISTING PAGING SPEAKERS, SECURE AND STORE. COIL AND SECURECURRENT WIRING TO KEEP FROM BEING DAMAGED DURING RENOVATION.
1/8" = 1'-0"TD-107
2 LEVEL 9 DEMOLITION PLAN - PARTIAL
BID DOCUMENTS - OCTOBER 05, 2018
10/05/18RESPONSIBLE CHARGE
SC
D
D
D
APG
D D
SC
DDD
D
D
DD
D
SC
APG
D
SC
SC
SC
D
SC SC
APG
DD
SC
D
D
D
D
D
D
SC
D
SC
APG
SC
V60" MH
IB
2
2
D
D
CR
CRCR
CR
CR
EDC1
CR
F
F
F
F
75F
F
F
F
F
F
F
F
F
F
D D D
EDC2
EDC4 EDC
5
EDC6
FF
F
F
F
F
F
F F F F
FF
F
FF
CC
D
DD
D
D
D D
D
D
D
DD D
D
DD
D
D D
D
D
D
D
D
D
D
D
D
D
DD
D
D
D
D
D
D
D
D
D
D
D
D
D
DD
D
D
D
D
D
D
D
D
D
D
DD
CC
CC
CC
D
D
APVA
APVA
APVA
APVA
APVA
AP
APVA
APVA
APVA
APVA
AP
V60" MH
1
APVA
EDC3
EDC7
EDC8
CR
CR
D
D
D
D
IA
V60" MH
IA
F
D
1
2
1
1
1
C-60563
C6-24-1CORRIDOR-1
S2-6STAIR
C6031
MECH.ROOM
C6032
MDOFFICE
C-6062
C-6060 C-6059 C-6058
C-6057
C-6055C-6056
C-6033
MECH.ROOM
C-6111
C-6110
C-6112
C6016-1
MDOFFICES-1
C6008-1PHYS-1
C6002
MDOFFICES
C6003CHIEF
C6007TLT RM
C6019MSA'S
C6030
MDOFFICE
C6024CHIEF
C6023
PRACTICEMNGR
C6021BUS MNGR
C6029PSA
C6006TLT RM
C6-22CORRIDOR
C6001LEARNERSC6-25
CORRIDOR
C6004BREAK RM
C6015
MDOFFICE
C6014PHYS
C6009LEARNERS
C6013LEARNERS
C6012RN
C6011CHIEF
C6010NP
C6005CONF RM
C6-24-2CORRIDOR-2
C6027N CHIEF
C6028MSA SUPV
C6025CHIEF
C6026-2N CHIEF-2
C6020VESTIBULE
C6022CONFERENCE
C6017
MDOFFICE
S1-6STAIR
601
139
6-25
631
6S2-6
7
6
4
5
6
6
6
MECH RMC6018
CORRIDOR-2C6-23-2
618
8
8
8
8
8
8
8
88
8
8
8
9
606
607
10
PROJECT NO.
10/05/18COVERINGTECHNOLOGY DESIGN
C:\B
IM\M
odel
\201
7-91
021-
Tec
hnol
ogy-
Cen
tral
_RLC
ondy
.rvt
10/5
/201
8 10
:49:
25 A
M
2017-91021
1/8" = 1'-0"TA-106
1 LEVEL 6 FLOOR PLAN
GENERAL PLAN NOTES:
1. GUEST WIRELESS ACCESS POINT LOCATION. PROVIDE ONE DATA.
2. COORDINATE DATA LOCATION WITH MECHANICAL CONTRACTOR.
3. EXISTING SIGNALS CLOSET. TERMINATE ALL NEW CABLING FROM THE 6TH FLOOR AT THIS LOCATION. REFER TO THE SPECIFICATIONS FOR DETAILS ON THE TERMINATION REQUIREMENTS.
4. BLACK ANALOG PHONE AND FAX LOCATION. CONFIRM LOCATION OF TERMINATION BLOCK IN THE SIGNALS CLOSET WITH THE OWNER. VA TO LIST PHONE NUMBERS FOR ANALOG CABLE TERMINATIONS.
5. FAX LOCATION. CONFIRM LOCATION OF TERMINATION BLOCK IN THE SIGNALS CLOSET WITH THE OWNER. VA TO LIST PHONE NUMBERS FOR ANALOG CABLE TERMINATIONS.
6. RE-INSTALL EXISTING CABLE FOR VIDEO SURVEILLANCE CAMERA. RE-INSTALL CAMERAS. COORDINATE FIELD-OF-VIEW WITH THE OWNER.
7. BEGIN CABLE LABELING IN "LEARNERS ROOM" C6001 AND CONTINUE CLOCKWISE.
8. VA WIRELESS ACCESS POINT LOCATION. PROVIDE ONE DATA.
9. EXISTING ACCESS CONTROL PANEL LOCATION. ADDITIONAL PANELS AND CARD READER MODULES NEEDED. CONTRACTOR TO VERIFY.
10. PROVIDE TWO (2) NETWORK SWITCHES, PART # CISCO WS-C3850-48F-L. PROVIDE TWO (2) UPLINK MODULES, PART # CISCO C3850-NM-4-1G. PROVIDE FOUR (4) AC POWER SUPPLIES, PART # PWR-C1-1100WAC. PROVIDE TWO (2) STACK CABLES, PART NUMBER # STACK-T1-50CM. PROVIDE TWO (2) POWER STACK CABLE, PART # CAB-SPWR-30CM. PROVIDE TWO (2) SMARTNET, PART # CON-SNT-WSC388FE. PROVIDE FOUR (4) SFP MODULE, PART # GLC-SX-MMD. COORDINATE LOCATION WITH OWNER PRIOR TO INSTALLATION.
BID DOCUMENTS - OCTOBER 05, 2018
10/05/18RESPONSIBLE CHARGE
D
SCD
DD
D D
SC
D D
D
APG
D
D
D
SC
D
D D
D
DSC
D
D
SC APG
SC APG
SC SC
DSC
SC
SC
APG
CR
CR
CR
CR
CR
CR
CR
CRCR
CR
EDC11
CR
CR
F
F F
F
F
F
110F F
FF
F
F
F
F
F
F
F
F
F
F
F
EDC12
EDC13
EDC10
EDC9
EDC14
EDC18
EDC16
EDC19
EDC17
F
F
N
N
N
N N
N
NN
N
N
NM
ND
ND
ND
ND
F
N
N
N
N
NN
N
N
R84" MH
CC 1
D
D
R84" MH
D
D D
D
D
D
D
D
EDC15
CR
N
N
N
ND
NS
NS
D
D
D
D
D DD D
D
D
D
DDDD
D DD
D
D
D
D D
D
D
D D
D D
D
D D
D
N
NNNN
N N N F
F
F
F
ND
ND
ND
N
N N NN
NNNN
N
APVA
APVA
APVA
APVA
APVA
APVA AP
VA
APVA
APVA
APVA
APVAAP
VAAPVA
APVA
APVA
APVA
APVA
APVA
APVA
D
D
EDC19
EDC22
APVA
CRD
N
D
D
D
60" MHVB I
D
D
HA
HD
SC APG
SC SC
F
F
DD
DD
AP
AP
SC SC
AP
1
1
2
1
1
3
701
703
TELE.ROOM
705
706
705A
707B
707A
740
725
7S2-7
739
T T
T
9
6
4
8
57
EXAMC7016
EXAMC7015
EXAM RM-2C7032-2
EXAM RM-2C7033-2
C7035-2
EXAM/PROCROOM-2
EXAM RM-2C7031-2
TEAM RM-2C7030-2
PAT TLT-2C7036-2
PAT TLT-2C7038-2
EXAM RM-2C7029-2
EXAM/PROC-4C7037-4
TYPICAL EXAM RM-2C7028-2
CORRIDOR-2C7-9-2
EXAM RM-2C7027-2
CLEAN STORAGE-2C7039-2
STAIR-22-7-2
SOILED UTILITY-2C7024-2
EXAMC7022
TEAM RMC7021 EXAM
C7020
EXAMC7019
TEAM RMC7018
EXAMC7017
CHECK OUT-2C7010-2
TEAM RM-2C7026-2
C7013
TYPICALTEAM RMEXAM
C7012EXAMC7011
RECEPT-3C7009-3
CORRIDORC7-10
WAITING ROOM-2C7007-2
PAT TLT-2C7008-2
HSKP-2C7006-2
C7005-2
BREAK RM/MAIL RM-2
LOCKERSC7001
LOCKERSC7003
STAFF TLT-2C7004-2
STAFF TLT-2C7002-2
MECH RM-2C7040-2
ELECC7025
TLT RMC7014
CORRIDOR-2C7-8-2
C-7059-2
C-7075-2
STAIR-21-7-2
C-7076
709
10
10
10
10
10
1010
10
10
10
10
10
10
10
10
10
10
10
10
10
11
707
724
1
C7-11
C7-10A-16
SHELLSPACE-16
C-9015CLOSET
C-9016CLOSET
C-9014
PROCESSING&
RECORDS
C-9013CLOSET
58CLOSET
57CLOSET
C-9010
HRSPECIALIZINGRECRUITMENT
&PLACEMENT
C-9027Room
C-9031CLOSET
C-9028
EMPLOYEE/LABORRELATIONS
C-9017
MEETINGROOM
C-9007BREAKROOM
C-9009STORAGE
C-9008STORAGE
C-9002
PERS.MANAG.
SPECIALIST
C-9005
PERS.MANAG.
SPECIALIST
C-9004
PERS.MANAG.
SPECIALIST
C-9003
PERS.MANAG.
SPECIALIST
C-9033Room
C-9037CLOSET
C-9038CLOSET
C-9032
MED.STAFF &NURSE
CREDENTIALING
C-9052
FIREEQUIPMENT
C-9051
ELEC.ROOM
C-9036
EMPLOYMENTINFORMATION
C9-3LOBBY
C-9050CLOSET
C-9039ENG.
C9-4LOBBY
C9-5CORRIDOR
C-9030
HRSPECIALIST
CLASSIFICATION
C-9035
HUMANRESOURCES
59
HUMANRESOURCES
C-9006
HUMANRESOURCES
12
12
13
12
PROJECT NO.
10/05/18COVERINGTECHNOLOGY DESIGN
C:\B
IM\M
odel
\201
7-91
021-
Tec
hnol
ogy-
Cen
tral
_RLC
ondy
.rvt
10/5
/201
8 10
:49:
33 A
M
2017-91021
1/8" = 1'-0"TA-107
1 LEVEL 7 FLOOR PLAN
1. GUEST WIRELESS ACCESS POINT LOCATION. PROVIDE ONE DATA.
2. COORDINATE DATA LOCATION WITH MECHANICAL CONTRACTOR.
3. EXISTING SIGNALS CLOSET. TERMINATE ALL NEW CABLING FROM THE 7TH FLOOR AT THIS LOCATION. REFER TO THE SPECIFICATIONS FOR DETAILS ON THE TERMINATION REQUIREMENTS.
4. BLACK ANALOG PHONE AND FAX LOCATION. CONFIRM LOCATION OF TERMINATION BLOCK IN THE SIGNALS CLOSET WITH THE OWNER. VA TO LIST PHONE NUMBERS FOR ANALOG CABLE TERMINATIONS.
5. FAX LOCATION. CONFIRM LOCATION OF TERMINATION BLOCK IN THE SIGNALS CLOSET WITH THE OWNER. VA TO LIST PHONE NUMBERS FOR ANALOG CABLE TERMINATIONS.
6. RE-INSTALL EXISTING CABLE FOR VIDEO SURVEILLANCE CAMERAS. RE-INSTALL CAMERAS. COORDINATE FIELD-OF-VIEW WITH THE OWNER.
7. HEALTHY VET KIOSK LOCATION.
8. NURSE CALL MASTER STATION LOCATION.
9. BEGIN CABLE LABELING IN "BREAK ROOM/MAIL ROOM" C7005 AND CONTINUE CLOCKWISE.
10. VA WIRELESS ACCESS POINT LOCATION. PROVIDE ONE DATA.
11. EXISTING ACCESS CONTROL PANEL LOCATION. ADDITIONAL PANELS AND CARD READER MODULES NEEDED. CONTRACTOR TO VERIFY.
12. UPON COMPLETION OF THE NEW CEILINGS, RE-CONNECT AP'S. CONFIRM THE AP'S ARE ACTIVATED. PERFORM SELF-CHECK WITH OWNER TO CONFIRM CONNECTION WITH AN OWNER PROVIDED DEVICE.
13. UPON COMPLETION OF THE NEW CEILINGS, RE-CONNECT PAGING SPEAKERS. CONFIRM THE PAGING SPEAKERS ARE FUNCTIONING PROPERLY VIA AUDIBLE TEST.
GENERAL PLAN NOTES:
1/8" = 1'-0"TA-107
2 LEVEL 7 FLOOR PLAN - ALTERNATE
1/8" = 1'-0"TA-107
3 LEVEL 9 FLOOR PLAN - PARTIAL
BID DOCUMENTS - OCTOBER 05, 2018
10/05/18RESPONSIBLE CHARGE
DM DM
EL EL
RX RX
CR
IP 2 DOORCONTROLLER
PB120V
DM DM
EL EL
RX RX
CR
PB120V
DATA DROP/POE
CONTROLLED CARD READER WITHOUTHANDICAP INTERFACE
NOTE: THIS DIAGRAM IS SCHEMATIC IN NATURE ONLY. IT IS INTENDED TOSHOW THE GENERAL CONFIGURATION OF THE SYSTEM. REFER TO THEDRAWINGS AND SPECIFICATION FOR THE EXACT WORK REQUIRED.
INTERIOR - CEILING RECESSED
~
2
3
1
CAMERA MOUNTING DETAIL NOTES1. EXISTING CAMERA TO BE RE-INSTALLED IN NEW CEILING.2. RE-PULL EXISTING DATA OUTLET AND RE-TERMINATE AT NEW CAMERA
LOCATION.3. PROVIDE NEW PATCH CABLE.
FINISH FLOOR
CEILING
FINISH FLOOR
CEILING
NON-SECURE SIDESECURE SIDE NON-SECURE SIDESECURE SIDE
1. MAGNETIC DOOR POSITION SWITCH.2. PROVIDE 0.5" CONDUIT FROM DOOR FRAME TO COMMON
SECURITY JUNCTION BOX ON SECURE SIDE OF DOOR PERDIVISION 26.
3. COMMON SECURITY JUNCTION BOX ON SECURE SIDE OF DOOR.(12"X12"X4" WITH SECURITY SCREW COVER) PER DIVISION 26.
4. PROVIDE 1" CONDUIT FROM COMMON SECURITY JUNCTION BOXBACK TO EITHER TR-01E OR TR-02E PER DIVISION 26.
5. ELECTRONIC DOOR LOCK.6. PROVIDE 0.75" CONDUIT FROM DOOR FRAME TO COMMON
SECURITY JUNCTION BOX ON SECURE SIDE OF DOOR PERDIVISION 26.
7. REQUEST TO EXIT SENSOR IN THE HARDWARE.8. WALL MOUNTED CREDENTIAL READER. PROVIDE 1-GANG BOX
AT 46" MH (UNLESS OTHERWISE NOTED) AND EXTEND 0.75"CONDUIT FROM BOX TO COMMON SECURITY JUNCTION BOX ONSECURE SIDE OF DOOR PER DIVISION 26.
86
5 7
2
1
4
5
686
5 75 7
5
6
1
2 2
3
4
3
EL
DETAIL NOTES
PROJECT NO.
10/05/18COVERINGTECHNOLOGY DESIGN
C:\B
IM\M
odel
\201
7-91
021-
Tec
hnol
ogy-
Cen
tral
_RLC
ondy
.rvt
10/5
/201
8 10
:49:
34 A
M
2017-91021
SCALE: NONE
CARD READER WITHOUT HANDICAP INTERFACE1
SCALE: NONE
IP CCTV MOUNTING DETAILS2
12" = 1'-0"TA-501
3 TECHNOLOGY DOOR ROUGH-IN
NOTES:
ELECTRONIC DOOR CONTROLS SCHEDULE
ED
C N
UM
BE
R
DO
OR
OP
EN
ING
NU
MB
ER
CONTROL LOCKS REQUEST TO EXIT DOOR MONITORAUTOMATIC DOOR
OPERATOR
SP
EC
IAL
DO
OR
NO
TE
SEAC INTERFACE POWER TYPE
QT
Y
FUNCTION LOCATION POSITION SWITCH L BOLTBOND
SENSOR MOTOR PUSHPLATE
RE
AD
ER
TO
D
FIR
E A
LAR
M
INT
ER
CO
M
PU
SH
BU
TT
ON
INT
RU
SIO
N A
LAR
M
PO
E /
PO
E+
VO
LTA
GE
LO
CA
L
RE
MO
TE
LO
CA
TIO
N
NO
TE
EP EL ES ML WL ALA
RM
SH
UN
T
UN
LOC
K
NO
TE
HA
RD
WA
RE
MO
TIO
N
WA
LL S
WIT
CH
NO
TE
QTY #P
#T
BA
LAN
CE
D
HIG
H S
EC
UR
ITY
RE
CE
SS
ED
SU
RF
AC
E
QTY QTY QTY EA
C IN
TE
RF
AC
E
QTY WIR
ELE
SS
1 601 24 TEL RM 85 1 1 DPDT 0 0 0 02 6-25 24 TEL RM 85 1 1 DPDT 0 0 0 03 633 24 TEL RM 85 1 1 DPDT 0 0 0 04 631 24 TEL RM 85 1 1 DPDT 0 0 0 05 618 24 TEL RM 85 1 1 DPDT 0 0 0 06 6S2-6 24 TEL RM 85 1 1 DPDT 0 0 0 07 604 24 TEL RM 85 1 1 DPDT 0 0 0 08 605 24 TEL RM 85 1 1 DPDT 0 0 0 09 705A 24 TEL RM 48 1 1 DPDT 0 0 0 010 706 24 TEL RM 48 1 1 DPDT 0 0 0 011 701 24 TEL RM 48 1 1 DPDT 0 0 0 012 703 24 TEL RM 48 1 1 DPDT 0 0 0 013 705 24 TEL RM 48 1 1 DPDT 0 0 0 014 707B 24 TEL RM 48 1 1 DPDT 0 0 0 015 709 24 TEL RM 48 1 1 DPDT 0 0 0 016 724 24 TEL RM 48 1 1 DPDT 0 0 0 017 740 24 TEL RM 48 1 1 DPDT 0 0 0 018 741 24 TEL RM 48 1 1 DPDT 0 0 0 019 7S2-7 24 TEL RM 48 1 1 DPDT 0 0 0 019 707 24 TEL RM 48 1 1 DPDT 0 0 1 122 725 24 TEL RM 48 1 1 DPDT 0 0 0 0
BID DOCUMENTS - OCTOBER 05, 2018
10/05/18RESPONSIBLE CHARGE
1
OUTLET TYPE "R"CATV-OUTLET
2-POSITION SINGLE GANG FACEPLATEWITH CLEAR LABEL WINDOWS:• ONE (1) MODULAR 8-POSITION JACK "GREEN"• ONE (1) CATEGORY 6 UTP CABLE "GREEN"• ONE (1) COAXIAL F CONNECTOR COUPLER• ONE (1) RG6 QUAD SHIELDED COAXIAL CABLECONDUIT PER DIVISION 26. JACKS, FACEPLATE, ANDCABLING PER DIVISION 27.
1
4
OUTLET TYPE "2" (DATA)
3
2
12" SLACK COILSTORED AT CONDUIT STUB
4-11/16" SQUARE X 2-7/8"DEEP BACKBOX
CEILING LINE FOR ACCESS POINT (AP) ANDVIDEO SURVEILLANCE CAMEA
(SOLID CEILING)
CEILING LINE
4-POSITION SINGLE GANG FACEPLATEWITH CLEAR LABEL WINDOWS:• TWO (2) MODULAR 8-POSITION JACK "GREEN"• TWO (2) CATEGORY 6 UTP CABLE "GREEN"CONDUIT PER DIVISION 26. JACKS, FACEPLATE, ANDCABLING PER DIVISION 27.
2
1" BUSHED CONDUITROUTED TO THE OVERHEADCABLE TRAY
12" SLACK COILSTORED AT CONDUIT STUB
1" BUSHED CONDUITROUTED TO THE OVERHEADCABLE TRAY
4-11/16" SQUARE X 2-7/8"DEEP BACKBOX
AP
1" BUSHED CONDUITROUTED TO THE OVERHEADCABLE TRAY
4-11/16" SQUARE X 2-7/8"DEEP BACKBOX
BOND TOCABLE TRAY
R D
CC
3
2
1
DETAIL NOTES1. SURFACE MOUNT UTP DATA JACK
ABOVE ACCESSIBLE CEILING.2. UTP DATA JACK3. PROVIDE BISQUIT OR SURFACE
MOUNTED BOX FOR "AP" AND "IP"CAMERA LOCATIONS.
FOR ACCESS POINT (AP) ANDVIDEO SURVEILLANCE CAMEA
(LAY-IN CEILING)
AI
V
HDMI
1-1/4" CONDUIT
DATA DROP TO TR
CATV DROP TO TR
DUPLEX POWER OUTLET
DUPLEX POWER OUTLET
DATA
HDMI
DUPLEX POWER OUTLET
2
FLOOR
CEILING
~
PROVIDE 12" SLACK COIL AT STUB-UP LOCATION
60" MH
1-1/4" CONDUIT STUB-UPABOVE CEILING
FSR PWB-200
CI
V
HDMI
DATA DROP TO TR
CATV DROP TO TR
DUPLEX POWER OUTLET
DUPLEX POWER OUTLET
FLOOR
55' - 3"60" MH
1-1/4" CONDUIT
CEILING
~
1-1/4" CONDUIT STUB-UPABOVE CEILING
PROVIDE 12" SLACK COIL AT STUB-UP LOCATION
FSR PWB-200
DATA
DUPLEX POWER OUTLET
1
1-1/4" CONDUIT STUB-UPABOVE CEILING
~
PROVIDE 12" SLACK COILAT STUB-UP LOCATION
R
DATA DROP TO TR
CATV DROP TO TR
DUPLEX POWER OUTLET
DUPLEX POWER OUTLET
FLOOR
84" MH
CEILING
~
1-1/4" CONDUIT STUB-UPABOVE CEILING.
PROVIDE 12" SLACK COIL AT STUB-UP LOCATION.
FSR PWB-200
1
2
21
1
PROJECT NO.
10/05/18COVERINGTECHNOLOGY DESIGN
C:\B
IM\M
odel
\201
7-91
021-
Tec
hnol
ogy-
Cen
tral
_RLC
ondy
.rvt
10/5
/201
8 10
:49:
36 A
M
2017-91021
1/8" = 1'-0"TA-502
1 TECHNOLOGY OUTLET DETAILS 1/8" = 1'-0"TA-502
4 AV HIGH/LOW OUTLET WITH HDTV - FLOOR BOX 2 - LEARNER'S ROOM 1/8" = 1'-0"TA-502
5 AV HIGH/LOW OUTLET WITH HDTV
1/8" = 1'-0"TA-502
6 FLOOR BOX 1 - LEARNER'S ROOM 1/8" = 1'-0"TA-502
7 AV HIGH/LOW OUTLET - DISPLAY MONITORS
3/4" = 1'-0"TA-502
3 SIGNALS CLOSET EQUIPMENT RACK
NOTES1. 1U WIRE MANAGER.2. 1U 48 PORT PATCH PANEL.
TYPICAL NEW MODULAR PATCH PANEL CONFIGURATION
BID DOCUMENTS - OCTOBER 05, 2018
10/05/18RESPONSIBLE CHARGE