BID DOCUMENTS FULLY SPRINKLERED Services ...

38
Level 7a 69'-5 1/4" 49-G 49-F 49-E.1 Level 7_781-5.25 69' - 5 1/4" Level 8_793-4.25 81' - 4 1/4" Level 8_BOS 78' - 10 1/4" 49-G 49-F 49-E.1 Level 7_781-5.25 69' - 5 1/4" Level 8_793-4.25 81' - 4 1/4" Level 8_BOS 78' - 10 1/4" 2 MH-401 RA RA RA SA SA OA SD 34"x10" 20"x16" 20"x68" 8"x22" 12"x30" 8"x32" 6"ø 10"x20" EA OA RAD OAD SA Level 7a 69'-5 1/4" 49-6 71 49-8.1 102 49-7 Level 7_781-5.25 69' - 5 1/4" Level 8_793-4.25 81' - 4 1/4" Level 8_BOS 78' - 10 1/4" 49-6 71 49-8.1 102 49-7 Level 7_781-5.25 69' - 5 1/4" Level 8_793-4.25 81' - 4 1/4" Level 8_BOS 78' - 10 1/4" 1 MH-401 OA RA RA RA EA 68"x20" 10"x34" 12"x40" 16"x20" 10"x20" 56"x20" 16"x50" RA 6"x10" EA RA EF-37 FD-5 FD-9 RAD OAD FD-7 SD 49-6 49-6 49-G 49-G 49-F 49-F 49-E.1 49-E.1 71 71 49-8.1 49-8.1 86 86 102 102 49-7 49-7 49-6 49-6 49-G 49-G 49-F 49-F 49-E.1 49-E.1 71 71 49-8.1 49-8.1 86 86 102 102 49-7 49-7 1 MH-401 2 MH-401 16"x7" 22"x8" 30"x12" 6"ø 28"x10" 32"x8" 6"x8" 34"x10" 16"x7" 50"x16" 40"x12" 20"x16" 20"x10" 20"x8" SD-1 200 CFM CAV-65 RG-3 200 CFM SA SA SA OA RA RA RA EA EA EA EA 10"x6" FD-5 FD-9 RA EA SA Project Number Building Number Drawing Number Project Title Location Issue Date Checked Drawn Drawing Title Approved: VA FORM 08 - 6231 A 3 BID DOCUMENTS FULLY SPRINKLERED Services Engineering and Facilities Management U.S. Department of Veterans Affairs B C D E A B C D E F 2 1 4 5 6 7 8 9 10 Phase ARCHITECT/ENGINEER OF RECORD F F E I n c Engineering and Technical Services 420 Springfield Pike Wyoming OH 45215 513-5322-0956 CONSULTANT 3 2 1 4 5 6 7 8 9 10 C H A M P L I N A R C H I T E C T U R E 720 East Pete Rose Way Suite 100 Cincinnati OH 45202 513-241-4474 INDIANAPOLIS VAMC LEVEL 6 & 7 RENOVATIONS Building #1 #583-14-129 10/05/18 RESPONSIBLE CHARGE 10/05/18 COVERING HVAC DESIGN C:\Users\kyleg\Documents\Revit Local Files\Indianapolis_Mechanical_kyle.guggenheim.rvt 10/5/2018 5:57:51 PM MH-401 MECHANICAL ROOM SECTIONS 10/05/18 PP KG 1/2" = 1'-0" MH-401 1 C7040 - MECHANICAL ROOM - SOUTH 1/2" = 1'-0" MH-401 2 C7040 - MECHANICAL ROOM - WEST 1/2" = 1'-0" MH-401 3 7TH FLOOR - NEW WORK - MECHANICAL ROOM Revisions: Date:

Transcript of BID DOCUMENTS FULLY SPRINKLERED Services ...

Level 7a69'-5 1/4"

49-G49-F49-E.1

Level 7_781-5.2569' - 5 1/4"

Level 8_793-4.2581' - 4 1/4"

Level 8_BOS78' - 10 1/4"

49-G49-F49-E.1

Level 7_781-5.2569' - 5 1/4"

Level 8_793-4.2581' - 4 1/4"

Level 8_BOS78' - 10 1/4"

2

MH-401

RA

RA

RA

SA

SA

OA

SD

34"x10"

20"x16"

20"x68"

8"x22"

12"x30"

8"x32"

6"ø

10"x20"EA

OA RAD

OAD

SA

Level 7a69'-5 1/4"

49-67149-8.1 102 49-7

Level 7_781-5.2569' - 5 1/4"

Level 8_793-4.2581' - 4 1/4"

Level 8_BOS78' - 10 1/4"

49-67149-8.1 102 49-7

Level 7_781-5.2569' - 5 1/4"

Level 8_793-4.2581' - 4 1/4"

Level 8_BOS78' - 10 1/4"

1

MH-401

OA

RA

RA

RA

EA

68"x20"

10"x34"

12"x40"

16"x20"

10"x20"

56"x20"

16"x50"RA

6"x10"EA

RA

EF-37

FD-5

FD-9

RAD

OAD

FD-7

SD

49-6

49-6

49-G 49-G

49-F 49-F

49-E.1 49-E.1

71

71

49-8.1

49-8.1

8686

102

102 49-7

49-7 49-6

49-6

49-G 49-G

49-F 49-F

49-E.1 49-E.1

71

71

49-8.1

49-8.1

8686

102

102 49-7

49-7

1

MH-401

2

MH-401

16"x7" 22"x8"

30"x12"6"ø

28"x10"

32"x8"

6"x8"

34"x10"

16"x7"

50"x16" 40"x12"

20"x16"

20"x10"

20"x8"

SD-1200 CFM

CAV-65

RG-3200 CFM

SA

SA

SA

OA

RA

RA

RA

EA

EA

EAEA

10"x6"

FD-5

FD-9

RA

EA

SA

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

10/05/18RESPONSIBLE CHARGE

10/05/18COVERING HVAC DESIGN

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/5

/2018 5

:57:5

1 P

M

MH-401

MECHANICAL ROOM SECTIONS

10/05/18 PP KG

1/2" = 1'-0"MH-401

1 C7040 - MECHANICAL ROOM - SOUTH

1/2" = 1'-0"MH-401

2 C7040 - MECHANICAL ROOM - WEST 1/2" = 1'-0"MH-401

3 7TH FLOOR - NEW WORK - MECHANICAL ROOM

Revisions: Date:

W2

W1

W

"D"

45°MAX.

W

1/2" 1/2" 1 1/2"

SE

E N

OTE

4

SEE NOTE 3

SEE NOTE 2

SEE NOTE 1

WITH 3-WAY CONTROL VALVE11

NTS

RADIANT PANEL COIL PIPING DETAIL

COIL

TEST PLUG (TYP.)

REDUCER, IF REQUIRED

WA

TER

RE

TUR

N

MANUAL AIR VENT

UNION CONNECTIONS(TYP.)

WA

TER

SU

PP

LY

BALANCING VALVE

DRAIN WITH HOSECONNECTION

MV NO C

NC

AUTOMATIC 3-WAYVALVE

CONNECT RUNOUT PIPING TOCOIL OFF TOP OF MAIN

WITH 2-WAY CONTROL VALVE7

NTS

AIR TERMINAL UNIT REHEAT COIL PIPING DETAIL

COIL

TEST PLUG (TYP.)

REDUCER, IF REQUIRED

WATER RETURN

MANUAL AIR VENT

UNION CONNECTIONS (TYP.)

WATER SUPPLY

SHUT OFF VALVE

DRAIN WITH HOSECONNECTION

MV

MODULATION CONTROL VALVE

4NTS

DUCTWORK SQUARE VANE ELBOWS

NOTE:

1.

2.

3.

4.

ALL VANE ELBOWS SHALL BE CONSTRUCTED AND INSTALLED AS DETAILED BY SMACNA.

WHEN W1 DOES NOT EQUAL W2, VANE SHALL BE SINGLE THICKNESS VANE TYPE REGARDLESS OF W DIMENSION.

ALL SINGLE THICKNESS VANES SHALL HAVE A 2" [50mm] RADIUS, 1 1/2" [40mm] MAXIMUM SPACE BETWEEN VANESAND A 3/4" [20mm] TRAILING EDGE.

WHEN W EQUALS W2 AND W1 IS GREATER THAN 20" [500mm] VANES SHALL BE DOUBLE VANE TYPE.

5NTS

SUPPLY DUCTWORK TAKE-OFFS

AIR SPLIT DUCT TAKE-OFF PLAN VIEW

BRANCH DUCT TAKE-OFF PLAN VIEW

SUPPLY REGISTER TAKE-OFF PLAN VIEW

AIR FLOW

AIR FLOW

AIR

FLO

W

SUPPLY REGISTER ORBRANCH DUCT

TURNING VANES

MAIN SUPPLYDUCT

SEE FLOOR PLAN FOR SPLITDIMENSION

PROVIDE VOLUME DAMPER

PROVIDE VOLUMEDAMPER

ADJUSTABLEMETAL ROD ORLINKAGE

TOP REGISTER

MAINSUPPLYDUCT

VOLUME EXTRACTOR; ADJUSTABLE FROM FULLYCLOSED POSITION TO CFM NOTED ON FLOOR PLANS

AIR FLOW AIR FLOW

1/4 W OR 4" [100mm] MIN.

AIR FLOW

MAIN SUPPLY DUCT

AIR

FLO

W

6NTS

SUPPLY DUCT TAKEOFF - AIR TERMINAL UNIT

RIGID DUCT TO AIR TERMINAL UNIT.

ROUND SHEET METAL DUCT.

MAIN SUPPLY

PLAN VIEW

9NTS

EXHAUST OR RETURN BRANCH DUCTWORK

MAIN EXHAUST OR RETURN

PLAN VIEW

AIR FLOW

AIR FLOW

PROVIDE VOLUME DAMPERAT EACH BRANCH DUCT

1/4W OR 4" [100mm] MIN.

BRANCH DUCT

VD

8NTS

VOLUME DAMPER DETAIL

NOTE:

1.

2.

DELETE INSULATION STAND-OFF ON DUCTWORK WITHOUT EXTERIOR INSULATION.

DETAIL SHOWS SINGLE BLADE DAMPER. DAMPER INSTALLATION SHALL BE SIMILAR FOR MULTI-BLADE DAMPERS &

ROUND DAMPERS.

INSULATION SEESPECIFICATION

DAMPER BLADE

1/8" [6mm]CLEARANCE ALLAROUND

OUTSIDE END BEARING

INSIDE END BEARING

HANDLE WITHLOCKING QUADRANT

INSULATIONSTAND-OFF

1/2" [15mm] ROUND ROD PIN

DUCT

STIFFEN BLADE ASREQUIRED

SIDE ELEVATION SECTION

SECTION "A-A"

"B" "B"

1ACCESS PANEL AND DOOR DETAILNTS

NOTES:

1. LATCHES SHALL BE OF THE WEDGE TYPE TO CLOSE DOORS TIGHTLY.2. HINGES ON THE ACCESS DOORS SHALL HAVE NON-CORROSIVE PINS.3. SEE SMACNA 2005, FIGURE 9-15

ACCESS PANEL

ACCESS DOOR

CASING

GASKETHANDLE INSIDE

FLEXIBLEWASHER

FACTORYFABRICATEDLATCH

SECTION "B-B"

INSULATION

DUCT

GASKET

INSULATION

INSULATION

"A"

"A"

3NTS

FLEXIBLE DUCT CONNECTIONS

ROUND FLEXIBLE CONNECTION

RECTANGULAR FLEXIBLE CONNECTION

FLANGED CONNECTION ONFAN SIDE

WASHER 1-1/2" [40mm] MIN. TO 3" [75mm] MAX. INSTALLED. 6"[150mm] NOMINAL WITH MATERIAL TAUT

FLEXIBLEMATERIAL ASSPECIFIED

1"x1/8" [25x3mm] DRAW BAND

1"x1/8" [25x3mm] BAND IRON

BOLT ON 4" [100mm] CENTERS

5/16" [8mm] FLANGE

DUCT

SHEET METAL SCREWS ON 12"[300mm] CENTERS

RIVET ON 4" [100mm]CENTERS

SHEET METAL ASSPECIFIED FORDUCTWORK.

1"x1/8" [25x3mm] BAND IRON

BOLT ON 4" [100mm] CENTERS

1" [25mm] FLANGE & HEMALTERNATEPOSITION OFBOLT 1 1/2" [40mm] POCKET

SLIP

DUCT

SHEET METAL ASSPECIFIED FORDUCTWORK.

[15mm] [15mm] [40mm]

1 1/2" [40mm] MIN. TO 3" [75mm] MAX. INSTALLED. 6"[150mm] NOMINAL WITH MATERIAL TAUTFLANGED

CONNECTION ONFAN SIDE

WASHER

FLEXIBLE MATERIAL ASSPECIFIED

2NTS

DUCT CONNECTIONS - AIR TERMINAL UNITS

NOTE:

1.

2.

3.

4.

5.

6.

RIGID STRAIGHT TERMINAL UNIT INLET LENGTH SHALL BE A

MINIMUM OF 3 TIMES THE DIAMETER OF INLET

A FLEXIBLE AIR DUCT CONNECTOR IS NOT MANDATORY FOR INLET TO THIS BOX, BUT ALLOWED TOACCOMMODATE MINOR OFFSETS. MAXIMUM LENGTH 3'-0" [900mm].

A BRANCH DUCT SERVING AN INDIVIDUAL BOX MAY BE THE SAME SIZE AS THE BOX INLET,PROVIDED THE EQUIVALENT LENGTH OF THE BRANCH DUCT, AS SHOWN, DOES NOT EXCEED 10

FEET (3 METERS). FOR LONGER LENGTHS, INCREASE THE DUCT SIZE AND PROVIDE A DUCTTRANSITION TO MAINTAIN THE DUCT STATIC PRESSURE DROP AT OR BELOW 0.2"/100' [1.64Pa/m].

FLEXIBLE AIR DUCT CONNECTORS, WHEN USED FROM TERMINAL UNIT SUPPLY AIR DUCT TODIFFUSER, SHALL NOT EXCEED 5'-0" [1500mm]. USE RIGID ELBOWS FOR CHANGE OF DIRECTIONGREATER THAN 45°.

COMPONENT ARRANGEMENT MAY VARY BY MANUFACTURER. PROVIDEINSULATION W/VAPOR BARRIER FOR CONNECTING DUCT SECTIONS.

USE OF THE FLEXIBLE AIR DUCT CONNECTORS ARE NOT PERMITTED FOR THE DEDICATED AHUSERVING THE SURGICAL SUITE.

AIR TERMINAL UNIT (CVOR VAV)

REHEAT COIL

SOUND ATTENUATOR SEEEQUIPMENTSCHEDULE

FLEXIBLE AIR DUCTCONNECTOR. SEE DETAIL

DIFFUSER (TYP.)

SEE SPECIFICATIONS FOR CLAMPS ANDSEALANT (TYP.)

SEE NOTE 5

PIPING CONNECTIONS10

NTS

HYDRONIC RADIANT CEILING PANELS -

RADIANT CEILING PANEL

HWS

HWR

RUNOUT & INTERCONNECTING PIPING. PROVIDEDIELECTRIC FITTINGS AS REQUIRED. CIRCUIT TOCOMPLY WITH SPECIFIED CAPACITY & PRESSUREDROP. (TYP.)

NOTE:

1. MINIMUM FLOW SHALL BE NO LESS THAN0.5 GPM [1.9 LPM]

NOTE:

1.

2.

FOR RUNOUT PIPING SIZE REFER TO AIR TERMINAL UNITMINIMUM RUNOUT PIPING SIZE SHALL BE 3_

4" DIAMETER

PROVIDE AUTOMATIC 3-WAY VALVE BASED ON ATU SCHEDULE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

10/05/18RESPONSIBLE CHARGE

10/05/18COVERING HVAC DESIGN

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/5

/2018 5

:57:5

1 P

M

MH-501

HVAC DETAILS I

10/05/18 PP KGRevisions: Date:

25m

m1"

MA

X

PROVIDE INSULATION SHIELD& INSERT FOR ALL PIPING(200mm [8"] MIN.)

BAND

43mm [1-5/8"] 12 GAUGECHANNEL OR 50x50x6.4mm[2"X2"X1/4"] ANGLE

15mm [1/2"] DIA.HANGER RODS WITH900mm [36"] MAX.SPACING ON EACHCHANNEL

WELD

SADDLE

INSULATION SHIELDAT HANGER

PROVIDE HIGH COMPRESSIVESTRENGTH INSULATION (9 PSF MIN.DENSITY) UNDER INSULATION SHIELD

INSULATION (VAPORBARRIER TYPE ISREQUIRED FOR LOWTEMPERATURE PIPE)

HANGER ROD

NOTE:SEE SPECIFER FOR DETAILED HANGER REQUIREMENTS

1"

5NTS

SIDE VIEW TRAPEZE HANGER FOR UP TO453KG [1000 LB.] UNIFORM LOAD

ADJUSTABLE CLEVIS HANGER TYPE 1 -SEE SPECIFICATIONS

ADJUSTABLE CLEVIS HANGER TYPE 43 -SEE SPECIFICATIONS

MAXIMUM PIPE/TUBING SUPPORT SPACING

NOTE: FOR TRAPEZE HANGER TAKE SPACING OF SMALLEST SIZE ON TRAPEZE.

NOM. SIZE

PIPE

TUBING

PIPE HANGERS

mm[IN]

mm[FT]

mm[FT]

THRU 20

[THRU 3/4]

2100[7]

1500[5]

25[1]

2100[7]

1800[6]

32

[11/4]

2100[7]

2100[7]

40

[11/2]

2700[9]

2400[8]

50[2]

3000[10]

2400[8]

65

[21/2]

3400[11]

2700[9]

75[3]

3700[12]

3000[10]

100[4]

4100[14]

3700[12]

125[5]

4900[16]

4000[13]

150[6]

5200[17]

4100[14]

200[8]

5800[19]

4900[16]

250[10]

6700[22]

--

300[12]

7000[23]

--

350[14]

7600[25]

--

400[16]

8200[27]

--

450[18]

8500[28]

--

500[20]

9100[30]

--

600[24]

9600[32]

--

6NTS

NOTES:1. SEE SPECIFICATION SECTION "PUMPS" FOR Y STRAINER OPTION

FIRST 3 HANGERS FOR EACH PIPE AND BRANCHSHALL BE SPRING & NEOPRENE TYPE. TYPE "H" FOR4" [100mm] DIA. PIPE & SMALLER. TYPE "H-P" FOR 5"[125mm] DIA. PIPE & LARGER.

RIGID PIPEHANGER

INSTALL HANGER AS CLOSE TO PIPEELBOW AS POSSIBLE (TYPICAL)

1/2" [15mm]

FLEXIBLE CONNECTOR (TYPICAL)

PUMP

FLOOR

VIBRATION ISOLATOR(TYPICAL)

1" [25mm] MIN.DIA. PIPE STAND

CONCRETE INERTIABASE

DRAIN

SUCTION DIFFUSERWITH BUILT IN STRAINER.OPTIONAL: LONG RADIUSELBOW AND INLETSTRAINER WITH 3XDIAMSTRAIGHT INLET TO PUMP

1/2" [15mm]

PRESSURE GAUGE

RIGID PIPEHANGER

SINGLE SUCTION FLOOR-MOUNTED PUMPS -CONNECTIONS WITH FLEXIBLE CONNECTORS

OPTIONAL STRAINER

BUTTERFLY OR BALLSHUT OFF VALVE, TYP.

CHECK VALVE

1

2NTS

FIRE DAMPER INSTALLATIONSECTION THRU

NOTE:

1.

2.

3.

4.

5.

6.

A VERTICAL DAMPER IS SHOWN. HORIZONTAL DAMPER INSTALLATION, 1S SIMILAR. FOLLOW DAMPER MANUFACTURER'SINSTRUCTIONS, INCLUDING FASTENER OPTIONS AND GAGES FOR SLEEVE AND PERIMETER ANGLES. FIRE DAMPERS MUSTBE INSTALLED IN THE PARTITION OR FLOOR AND NOT OUTSIDE THE PENETRATION.

GALVANIZED SLEEVE: GAGE NOT LESS THAN CONNECTING DUCT. FASTEN SLEEVE TO DAMPER FRAME AND TOPERIMETER ANGLES.

PERIMETER ANGELS: GALVANIZED STEEL, NOT LESS THAN 1 1/2"x1 1/2" [40x40mm], 14 GAGE, TO PROVIDE 1" [25mm]MINIMUM OVERLAP OF OPENING ON ALL 4 SIDES.

BREAKAWAY DUCT CONNECTION: CONTRACTOR'S OPTION OF TYPES SHOWN IN SMACNA.ACCESS PANELS: SIZE AND LOCATION TO PERMIT SERVICING THE FUSIBLE LINK OR LINKS.

PROVIDE 1/4" TO 1/2" [6 TO 15mm] CLEARANCE ON HEIGHT AND WIDTH. FILL OPEN SPACE WITH ROCK WOOL FIRESTOPFIBER.

ALL DUCT WORK RISERS WHICH ARE RUN EXPOSED, SUCH AS THRU ATTIC FLOORS AND MECHANICAL ROOM FLOORS,SHALL BE PROVIDED WITH 3" [75mm] HIGH CONCRETE CURB AROUND OPENING FOR DUCT.

SLEEVE, NOTE 2

DUCTCONNECTIONNOTE 4

DAMPER, NOTE 1

DAMPER COLLAR EXTENSIONINTEGRAL PART OF SLEEVE

SLEEVE, NOTE 2

NOTE 6FIRE BARRIER PARTITION ORCHASE

TYPICAL DUCTINSULATION

PERIMETER ANGLE, NOTE 3 (NOTEFASTENED TO PARTITION)

ACCESSPANEL NOTE 5

[25m

m]

4NTS

SMOKE DAMPER CONTROLS1

NTS

TYP ROOM WITH EXTERIOR EXPOSURE

3/4" HWS

3/4" HWR

VARIABLE AIR VOLUMETERMINAL WITH HOT

WATER REHEAT

HD

3/4" HWS

3/4" HWR

RADIANT CEILINGHEATING PANEL

WINDOW

WALL

WALL

4'-0"

2'-0"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

10/05/18RESPONSIBLE CHARGE

10/05/18COVERING HVAC DESIGN

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/5

/2018 5

:57:5

2 P

M

MH-502

HVAC DETAILS II

10/05/18 PP KGRevisions: Date:

VARIABLE AIR VOLUMEAIR TERMINAL UNIT & RADIANT PANEL

HOT HEATING WATERRISER DIAGRAM - EAST AND WEST CHASES

HEATING HOT WATERHEAT EXHANGER DIAGRAM

9TH FLOOR

8TH FLOOR

7TH FLOOR

6TH FLOOR

5TH FLOOR

4TH FLOOR

3RD FLOOR

2ND FLOOR

1ST FLOOR

BASEMENT

PENTHOUSE

EXISTING 4" HWS

EXISTING 4" HWR

EXIST. HWS

EXIST. HWR

NEW 4" HWS

NEW 4" HWR

EXIST. HWS

EXIST. HWR

EXIST. HWS

EXIST. HWR

WEST CHASE EAST CHASE

EXIST. HWS

EXIST. HWR

EXIST. HWS

EXIST. HWR

EX

IST

. H

WS

EX

IST

. H

WR

NE

W 4

" H

WR

NE

W 4

" H

WS

EX

IST

. H

WR

EX

IST

. H

WS

TO HEXC5

FROM HEXC5

HEXC5

PUMPED COND ANDPREHEAT SYSTEM

L. P. STEAM

TO HWSPUMPS

HWR

FILTER

A.S.

CHEMICALBY-PASSFEEDER

FROMHWSPUMPS

TO HWSUSERS

EXIST. HWS

EXIST. HWR

EXIST. HWS

EXIST. HWR

EXIST. HWS

EXIST. HWR

EXIST. HWS

EXIST. HWR

EXIST. HWS

EXIST. HWR

EXIST. HWS

EXIST. HWR

EXIST. HWS

EXIST. HWR

EXIST. HWS

EXIST. HWR

EXIST. HWS

EXIST. HWR

EXIST. HWS

EXIST. HWR

EXIST. HWS

EXIST. HWR

EXIST. HWS

EXIST. HWR

NEW HWS

NEW HWR

NEW HWS

NEW HWR

EXIST. HWS

EXIST. HWR

EXIST. HWS

EXIST. HWR

C SPACE TEMP

SENSOR

T

T

SUPPLY

HW

HH

WH

R

C

HW

HS

HW

HR

PANEL

TERMINAL

TO HEATING COIL

SEQUENCES OF OPERATIONA. GENERAL:

1. HVAC SYSTEMS SHALL BE CONTROLLED WITH DIRECT DIGITAL CONTROL (DDC) ACCORDING TO SEQUENCES SHOWN.

2. ADDITIONAL POINTS OR SOFTWARE PROGRAMMING NOT LISTED BUT WHICH ARE REQUIRED TO MEET FOLLOWING SEQUENCES OF

OPERATION SHALL BE PROVIDED.

3. HOUSE CONTROLLERS, RELAYS, TRANSDUCERS, AND OTHER COMPONENTS REQUIRED FOR STAND-ALONE CONTROL SHALL BE

PROVIDED INSIDE A NEMA 1 ENCLOSURE WITH LOCKABLE DOOR.

4. ACTUATORS ON MOTORIZED VALVES AND DAMPERS ON AIR HANDLING UNITS, CHILLED WATER, AND HOT WATER SYSTEMS TO BE DDC.

SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.

5. ALL FIRE/SMOKE DAMPERS SHALL BE MONITORED BY BAS FOR TROUBLE CONDITIONS.

6. ALL AH AND SYSTEM SMOKE DAMPERS SHALL BE HARD-WIRE INTERLOCKED SUCH THAT THEY CLOSE FULLY WHEN AH FANS STOP.

7. A HAND-OFF-AUTO SWITCH FEATURE AT THE AH SUPPLY FAN AND AT EACH REMOTE EXHAUST FAN EF-32 AND EF-37 PERMITS MANUAL

OR AUTOMATIC OPERATION OF EACH FAN.

A) IN AUTO MODE, THE FAN IS ENABLED AND DISABLED BY THE DDC SYSTEM.

B) IN HAND MODE, THE FAN IS ENABLED FOR OPERATION REGARDLESS OF THE COMMAND FROM THE DDC SYSTEM. THE DDC SYSTEM

STILL MAY ATTEMPT TO ISSUE COMMANDS TO CONTROL THE FAN AND WILL CONTROL OTHER CONTROL LOOPS, BUT HAND MODE

TAKES THE FAN OUT OF AUTO MODE AND MANUALLY OVERRIDES THE FAN ON.

C) IN OFF MODE, THE FAN IS DISABLED REGARDLESS OF THE COMMAND FROM THE DDC SYSTEM. OFF MODE TAKES THE FAN OUT OF

AUTO MODE AND MANUALLY OVERRIDES THE FAN OFF.

D) SAFETIES (FREEZESTAT, HIGH AND LOW STATIC PRESSURE SWITCHES) OVERRIDE ALL HAND-OFF-AUTO COMMANDS AND FORCE THE

FANS OFF UNTIL MANUALLY RESET.

8. THE AH SUPPLY FAN AND BOTH REMOTE EXHAUST FANS EACH HAVE A CURRENT SWITCH FOR STATUS. IF THE SUPPLY FAN STATUS

OR EITHER REMOTE EXHAUST FAN INDICATES OFF, A HARDWIRED INTERLOCK CAUSES THE OTHER FANS TO GO OFF, OUTSIDE AIR

DAMPER TO CLOSE, RETURN AIR DAMPER TO OPEN, SMOKE DAMPERS AT AH AND EACH FAN TO CLOSE, AND EACH EXHAUST FAN

SHUTOFF DAMPER TO CLOSE.

B. SETPOINTS:

1. ALL SETPOINTS GIVEN IN THE SEQUENCE OF OPERATIONS OR IN THE DRAWINGS ARE FOR SYSTEM STARTUP AND ARE PRELIMINARY

AND SHALL BE ADJUSTABLE.

2. OPTIMUM OPERATING SETPOINTS MUST BE DETERMINED DURING ACTUAL OCCUPANCY AND WILL BE AFFECTED BY MANY FACTORS.

THESE MAY INCLUDE:

A) WEATHER CONDITIONS.

B) BUILDING OCCUPANCY.

C) BUILDING UTILIZATION PATTERNS.

D) VARIATIONS IN BUILDING CONSTRUCTION.

E) VARIATIONS IN OPERATING CHARACTERISTICS OF ACTUAL INSTALLED BUILDING EQUIPMENT.

IT IS THE RESPONSIBILITY OF THE BUILDING OPERATORS TO DETERMINE THOSE SETTINGS AND OPERATING METHODS WHICH

PROVIDE THE BEST BALANCE OF OPERATING EFFICIENCY AND OCCUPANT COMFORT. THIS IS AN ONGOING PROCESS. OPTIMUM

SETTINGS CHANGE AS OPERATING CONDITIONS CHANGE.

C. AIR HANDLING UNIT AH-70 AND REMOTE EXHAUST FANS EF-32 AND EF-37

1. GENERAL:

A) AH-70 IS A MINIMUM OUTSIDE AIR, VARIABLE AIR VOLUME WITH VARIABLE AIR VOLUME TERMINAL UNITS WITH REHEAT AND

PERIMETER RADIANT HEATING CEILING PANELS. THE AH HAS MIXING DAMPERS (OUTSIDE AIR DAMPER AND RETURN AIR DAMPER),

OUTSIDE AIRFLOW MEASURING STATION, SINGLE POINT TYPE RETURN TEMPERATURE SENSOR, RETURN HUMIDITY SENSOR,

RETURN SMOKE DAMPER WITH END SWITCH, RETURN SMOKE DETECTOR, LOW STATIC PRESSURE SWITCH, PREFILTER WITH

DIFFERENTIAL PRESSURE GAUGE, LOW LIMIT THERMOSTAT (FREEZESTAT), CHILLED WATER COOLING COIL WITH THREE-WAY VALVE,

AVERAGING TYPE COOLING COIL DISCHARGE AIR TEMPERATURE SENSOR (TS-1), SUPPLY FAN WITH VFD, AVERAGING TYPE

DISCHARGE AIR TEMPERATURE SENSOR (TS-2), HIGH STATIC PRESSURE SWITCH, SUPPLY SMOKE DETECTOR, SUPPLY SMOKE

DAMPER WITH END SWITCH, AND A DIFFERENTIAL STATIC PRESSURE SENSOR. TWO REMOTE EXHAUST FANS (EF-32 & EF-37) ARE

INTERLOCKED WITH AH-70. EACH REMOTE EXHAUST FAN HAS AN EXHAUST SMOKE DETECTOR, A MOTORIZED EXHAUST SHUTOFF

DAMPER, A SMOKE DAMPER WITH END SWITCH, AN EXHAUST FAN AIRFLOW MEASURING STATION, A LOW STATIC PRESSURE

SWITCH, AND A VFD.

B) AH SUPPLY AND REMOTE EXHAUST FANS SHALL EACH BE INTERLOCKED THROUGH A DAMPER END SWITCH, SO EACH CANNOT

START UNTIL ITS RESPECTIVE OUTSIDE OR EXHAUST AND SMOKE DAMPER ARE FULLY OPEN.

C) THE UNIT'S OCCUPIED, UNOCCUPIED, PRE-OCCUPANCY TIME PERIOD IS DETERMINED BY A TIME SCHEDULE AND PROGRAMMING.

2. UNOCCUPIED MODE:

A) DURING UNOCCUPIED MODE, THE AH IS OFF UNLESS THERE IS A CALL FOR HEATING OR COOLING OR DEHUMIDIFICATION TO

MAINTAIN UNOCCUPIED SPACE SETPOINTS OR FOR UNOCCUPIED MORNING WARM-UP OR COOL-DOWN CYCLE. WHEN THE AH IS

OFF, SUPPLY FAN AND REMOTE EXHAUST FANS ARE OFF, AND ALL DAMPERS AND VALVES GO TO NORMAL POSITIONS AS SHOWN ON

THE AH AND REMOTE EXHAUST FAN CONTROL SCHEMATICS.

B) UNOCCUPIED SPACE SETPOINTS ARE AS FOLLOWS:

UNOCCUPIED HEATING SETPOINT 60°F (ADJUSTABLE).

UNOCCUPIED COOLING SETPOINT 82°F (ADJUSTABLE).

WHENEVER AH IS STARTED TO MAINTAIN UNOCCUPIED SPACE SETPOINTS, IT BEHAVES AS IF IN OCCUPIED MODE EXCEPT IN FULL

RETURN MODE WITH OUTDOOR AIR DAMPER CLOSED AND REMOTE EXHAUST FANS REMAIN OFF. WHEN UNOCCUPIED SPACE

SETPOINTS ARE SATISFIED, THE AH WILL STOP.

C) UNOCCUPIED HEATING SETBACK MODE IS MAINTAINED AS FOLLOWS: IF ANY SPACE SENSOR READS BELOW THE UNOCCUPIED

HEATING SETPOINT, THE AH WILL BE STARTED AND RUN UNTIL ALL UNOCCUPIED HEATING SPACE SETPOINTS ARE SATISFIED. THE

AH MIXING DAMPERS WILL MODULATE TO FULL RETURN MODE TO MAINTAIN THE HIGHEST SUPPLY AIR TEMPERATURE SETPOINT

POSSIBLE. TERMINAL UNITS IN UNSATISFIED SPACES WILL BEHAVE AS IF IN OCCUPIED MODE UNTIL SETPOINT IS SATISFIED.

D) UNOCCUPIED COOLING SETUP MODE IS MAINTAINED AS FOLLOWS: IF ANY SPACE SENSOR READS ABOVE THE UNOCCUPIED

COOLING SETPOINT, THE AH WILL BE STARTED AND RUN UNTIL ALL UNOCCUPIED COOLING SPACE SETPOINTS ARE SATISFIED. THE

AH COOLING COIL VALVE WILL MODULATE OPEN TO MAINTAIN THE LOWEST RESET AH SUPPLY AIR TEMPERATURE SETPOINT. SEE

AH SUPPLY AIR TEMPERATURE RESET SCHEDULE. TERMINAL UNITS IN UNSATISFIED SPACES WILL BEHAVE AS IF IN OCCUPIED

MODE UNTIL SETPOINT IS SATISFIED.

3. PRE-OCCUPANCY MODE:

A) PRE-OCCUPANCY MODE IS INITIALLY SCHEDULED, AND THE SCHEDULED START TIME IS OPTIMIZED BASED ON INSIDE AND OUTSIDE

AIR TEMPERATURE AND SYSTEM HISTORY OF PERFORMANCE. THE DDC CONTROLLER CALCULATES THE OPTIMUM

PRE-OCCUPANCY MODE HEATING/COOLING TIME NECESSARY TO BRING BUILDING TO OCCUPIED TEMPERATURE IN EITHER

WARM-UP OR COOL-DOWN CYCLES.

B) UPON INITIATION OF A START IN PRE-OCCUPANCY MODE (WARM-UP OR COOL-DOWN CYCLE), THE FOLLOWING EVENTS OCCUR:

1) OPEN RETURN AIR DAMPER AND RETURN AND SUPPLY AIR SMOKE DAMPERS.

2) OUTSIDE AIR DAMPER SHALL REMAIN CLOSED.

3) REMOTE EXHAUST FANS SHALL REMAIN OFF.

4) WHEN AH RETURN, AND SUPPLY SMOKE DAMPERS ARE FULLY OPEN, END SWITCHES SHALL ALLOW AH SUPPLY FAN TO

START.

C) PRE-OCCUPANCY WARM-UP CYCLE: DURING PRE-OCCUPANCY MODE, THE DDC SYSTEM OPERATES THE UNIT IN ITS WARM-UP

CYCLE IF THE AVERAGE SPACE TEMPERATURE OF THE VAV BOX ZONES SERVED BY THE UNIT IS BELOW 70°F (ADJUSTABLE). THE

FOLLOWING EVENTS OCCUR DURING PRE-OCCUPANCY WARM-UP CYCLE:

1) OUTSIDE AIR DAMPER IS CLOSED.

2) RETURN AIR DAMPER IS OPEN.

3) REMOTE EXHAUST FANS ARE OFF.

4) AH COOLING COIL VALVE IS CLOSED TO COIL.

5) THE AH MIXING DAMPERS WILL MODULATE TO FULL RETURN MODE TO MAINTAIN THE HIGHEST RESET AH SUPPLY AIR

TEMPERATURE SETPOINT POSSIBLE. SUPPLY FAN WILL MODULATE TO MAINTAIN SUPPLY DUCT STATIC PRESSURE AT SETPOINT.

6) TERMINAL UNITS WILL BEHAVE AS IF IN OCCUPIED MODE UNTIL EACH OCCUPIED SPACE SETPOINT IS SATISFIED.

7) WARM-UP MODE IS TERMINATED WHEN THE UNIT IS INDEXED TO ITS OCCUPIED MODE TIME PERIOD, OR WHEN ALL SPACES

REACH THEIR OCCUPIED HEATING SPACE TEMPERATURE SETPOINTS BEFORE OCCUPIED MODE TIME PERIOD BEGINS. SEE

OCCUPIED MODE SEQUENCE FOR OCCUPIED SPACE TEMPERATURE SETPOINTS.

D) PRE-OCCUPANCY COOL-DOWN CYCLE: DURING PRE-OCCUPANCY MODE, THE DDC SYSTEM OPERATES THE UNIT IN ITS COOL-DOWN

CYCLE IF THE AVERAGE SPACE TEMPERATURE OF THE VAV BOX ZONES SERVED BY THE UNIT IS ABOVE 75°F (ADJUSTABLE). THE

FOLLOWING EVENTS OCCUR DURING PRE-OCCUPANCY COOL-DOWN CYCLE:

1) OUTSIDE AIR DAMPER IS CLOSED.

2) RETURN AIR DAMPER IS OPEN.

3) REMOTE EXHAUST FANS ARE OFF.

4) THE AH MIXING DAMPERS WILL MODULATE TO FULL RETURN MODE AND THE AH COOLING COIL VALVE WILL MODULATE OPEN

TO MAINTAIN THE LOWEST RESET AH SUPPLY AIR TEMPERATURE SETPOINT. SEE AH SUPPLY AIR TEMPERATURE RESET

SCHEDULE.

5) SUPPLY FAN WILL MODULATE TO MAINTAIN SUPPLY DUCT STATIC PRESSURE AT SETPOINT.

6) TERMINAL UNITS WILL BEHAVE AS IF IN OCCUPIED MODE UNTIL EACH OCCUPIED SPACE SETPOINT IS SATISFIED.

7) COOL-DOWN MODE IS TERMINATED WHEN THE UNIT IS INDEXED TO ITS OCCUPIED MODE TIME PERIOD, OR WHEN ALL SPACES

REACH THEIR OCCUPIED COOLING SPACE TEMPERATURE SETPOINTS BEFORE OCCUPIED MODE TIME PERIOD BEGINS. SEE

OCCUPIED MODE SEQUENCE FOR OCCUPIED SPACE TEMPERATURE SETPOINTS.

4. OCCUPIED MODE:

A) OCCUPIED SCHEDULE: OCCUPIED MODE STARTS BASED ON AN ADJUSTABLE SCHEDULE.

B) UPON A TRANSITION FROM PRE-OCCUPANCY MODE TO OCCUPIED MODE, THE FOLLOWING EVENTS OCCUR:

1) OPEN BOTH REMOTE EXHAUST FAN SHUTOFF AND SMOKE DAMPERS.

2) OUTSIDE AIR DAMPER SHALL BE OPENED TO ITS MINIMUM OUTDOOR AIR POSITION.

3) WHEN OUTDOOR AND DAMPER AND BOTH REMOTE EXHAUST FAN SMOKE DAMPERS ARE FULLY OPEN, END SWITCHES SHALL

ALLOW BOTH EXHAUST FANS TO START.

4) SUPPLY AND EXHAUST FANS RUN CONTINUOUSLY DURING OCCUPIED MODE, AND IF THEY ARE ALL RUNNING, THE DDC

SYSTEM INDEXES THE UNIT TO OCCUPIED MODE.

5) OCCUPIED SPACE SETPOINTS ARE AS FOLLOWS:

OCCUPIED HEATING SETPOINT 70°F (ADJUSTABLE).

OCCUPIED COOLING SETPOINT 75°F (ADJUSTABLE).

6) THE FOLLOWING AH CONTROL LOOPS WILL OPERATE TO MAINTAIN SETPOINTS DURING OCCUPIED MODE:

A. COOLING DISCHARGE AIR TEMPERATURE CONTROL LOOP.

B. MIXED AIR TEMPERATURE CONTROL LOOP.

C. MINIMUM OUTDOOR AIR CONTROL LOOP.

D. SUPPLY AIR DUCT STATIC CONTROL LOOP.

C) COOLING DISCHARGE AIR TEMPERATURE CONTROL LOOP:

1) MIXED AIR DAMPERS (OUTDOOR AND RETURN AIR DAMPERS) AND COOLING COIL VALVE SHALL MODULATE IN SEQUENCE TO

MAINTAIN THE RESET COOLING DISCHARGE AIR TEMPERATURE SETPOINT AT DISCHARGE AIR TEMPERATURE SENSOR TS-2.

2) THE UNIT'S DISCHARGE AIR TEMPERATURE SETPOINT IS RESET BASED ON VAV BOX WITH THE HIGHEST COOLING DEMAND.

DISCHARGE AIR TEMPERATURE RESET SCHEDULE:

A. DISCHARGE AIR TEMPERATURE SHALL BE RESET USING TRIM AND RESPOND LOGIC WITHIN THE RANGE 52°F (ADJUSTABLE) TO 62°F

(ADJUSTABLE). WHEN THE FAN IS OFF, FREEZE T-MAX AT THE MAXIMUM VALUE (62°F). WHILE FAN IS PROVEN ON, EVERY 2 MINUTES

(ADJUSTABLE), INCREASE THE SETPOINT BY 0.2°F (ADJUSTABLE) IF THERE ARE TWO (ADJUSTABLE) OR FEWER ZONE COOLING

REQUESTS. [ADJUST THE “TWO” OR FEWER ZONE COOLING REQUESTS VALUE TO LIMIT DOMINANCE OF ROGUE ZONES.] IF THERE ARE

MORE THAN TWO (ADJUSTABLE) COOLING REQUESTS, DECREASE THE SETPOINT BY 0.3°F (ADJUSTABLE). A COOLING REQUEST IS

GENERATED WHEN THE COOLING LOOP OF ANY ZONE SERVED BY THE SYSTEM IS >99% (ADJUSTABLE).

D) MIXED AIR TEMPERATURE CONTROL LOOP:

1) MIXED AIR DAMPERS (OUTDOOR AND RETURN AIR DAMPERS) SHALL MODULATE TO MAINTAIN THE MIXED AIR TEMPERATURE

SETPOINT OF 68°F (ADJUSTABLE).

E) MINIMUM OUTDOOR AIR CONTROL LOOP:

1) MIXED AIR DAMPERS (OUTDOOR AND RETURN AIR DAMPERS), BOTH EXHAUST FANS, AND SUPPLY FAN SHALL MODULATE IN

SEQUENCE TO MAINTAIN 4,200 CFM (ADJUSTABLE) MINIMUM OUTDOOR AIR SETPOINT MEASURED AT THE MINIMUM OUTDOOR

AIRFLOW MEASURING STATION.

2) EXHAUST FAN EF-32 (SERVES 6TH FLOOR) MODULATES TO MAINTAIN AIRFLOW SETPOINT AT 1,800 CFM (ADJUSTABLE), AND

EF-37 (SERVES 7TH FLOOR) MODULATES TO MAINTAIN AIRFLOW SETPOINT AT 2,200 CFM (ADJUSTABLE).

F) SUPPLY AIR DUCT STATIC CONTROL LOOP:

1) SUPPLY FAN MODULATES TO MAINTAIN A RESET DUCT STATIC PRESSURE SETPOINT WHENEVER THE SUPPLY FAIN RUNS.

DUCT STATIC PRESSURE SENSOR SHALL BE LOCATED APPROXIMATELY 2/3 OF THE WAY DOWNSTREAM OF THE AH. OPTIMUM

LOCATION SHALL BE DETERMINED IN THE FIELD BASED ON FIELD CONDITIONS AND MANUFACTURER'S INSTALLATION

INSTRUCTIONS. FINAL SETPOINTS SHALL BE DETERMINED WITH THE ASSISTANCE OF THE BALANCE CONTRACTOR.

2) SUPPLY AIR DUCT STATIC PRESSURE RESET LOGIC (TRIM & RESPOND):

STATIC PRESSURE SETPOINT SHALL BE RESET USING TRIM AND RESPOND LOGIC WITHIN THE RANGE 0.15 INWG (ADJUSTABLE) TO

2 INWG (ADJUSTABLE) AS SET BY BALANCE CONTRACTOR. WHEN FAN IS OFF, FREEZE SETPOINT AT THE MINIMUM VALUE. WHILE

FAN IS PROVEN ON, EVERY 2 MINUTES (ADJUSTABLE), DECREASE SETPOINT BY 0.04 INWG (ADJUSTABLE) IF THERE ARE TWO

(ADJUSTABLE) OR FEWER PRESSURE REQUESTS. [ADJUST THE “TWO” OR FEWER ZONE COOLING REQUESTS VALUE TO LIMIT

DOMINANCE OF ROGUE ZONES.] IF THERE ARE MORE THAN TWO (ADJUSTABLE) PRESSURE REQUESTS, INCREASE THE SETPOINT

BY 0.04 INWG (ADJUSTABLE). WHERE VAV ZONE DAMPER POSITION IS KNOWN, A PRESSURE REQUEST IS GENERATED WHEN ANY

VAV DAMPER SERVED BY THE SYSTEM IS WIDE OPEN. WHERE VAV ZONE DAMPER POSITION IS UNKNOWN, A PRESSURE

REQUEST IS MADE WHEN THE RATIO OF THE ZONE'S ACTUAL SUPPLY AIRFLOW TO SUPPLY AIRFLOW SETPOINT IS LESS THAN 90%

(ADJUSTABLE).

G) AH SHUTDOWN MODE: UPON AH SUPPLY FAN AND REMOTE EXHAUST FAN SHUTDOWN, ALL AH, BOTH EXHAUST FAN SYSTEM

SMOKE DAMPERS AND EXHAUST FAN SHUTOFF DAMPER SHALL CLOSE FULLY. OUTSIDE AIR DAMPER CLOSES FULLY AND RETURN

AIR DAMPER OPENS FULLY. AH DAMPER OPERATORS SHALL BE ADJUSTED SUCH THAT CLOSING OF SMOKE DAMPERS WILL BE

DELAYED UNTIL FAN ROLLS TO NEAR STOP.

1) SAFETIES:

2) ALL SAFETY/EMERGENCY CONTROLS SHALL BE HARD-WIRE INTERLOCKED SUCH THAT THEY ARE NOT DEPENDENT UPON DDC

SYSTEM SOFTWARE.

3) SMOKE CONTROL:

A) DUCT MOUNTED AIR SMOKE DETECTORS WILL BE FURNISHED AND INSTALLED AS SHOWN. PROVIDE POWER AND ALARM, CONTROL

AND INTERLOCK WIRING.

B) WHENEVER ANY DUCT-MOUNTED SMOKE DETECTOR GOES INTO ALARM, IT SHALL PERFORM THE FOLLOWING:

1. STOP ALL UNIT FANS.

2. CLOSE ALL ASSOCIATED SMOKE DAMPERS.

3. NOTIFY THE FIRE ALARM SYSTEM.

4. THIS CONTROL MUST BE MANUALLY RESET.

5. SMOKE ALARMS AFFECT ONLY AIR SYSTEMS SERVING THE ZONE IN ALARM. AIR SYSTEMS SERVING THE OTHER ZONES

CONTINUE TO OPERATE NORMALLY.

4) FREEZE PROTECTION:

A) IF THE AIR TEMPERATURE SENSED BY THE LOW LIMIT THERMOSTAT (FREEZESTAT) FZ-1 FALLS BELOW 45°F (ADJUSTABLE), AN

ALARM SHALL INDICATE AT THE ECC OPERATOR CONTROL PANEL (OCP).

B) IF THIS TEMPERATURE FALLS BELOW 40°F (ADJUSTABLE), THE SUPPLY FAN AND BOTH EXHAUST FANS SHALL SHUT DOWN AND A

CRITICAL ALARM SHALL INDICATE AT ECC OCP.

5) LOW STATIC PRESSURE AT EXHAUST FANS AND AH SUPPLY FAN

A) IF THE PRESSURE SWITCH LOW (PSL) AT EITHER EXHAUST FAN OR AH SUPPLY FAN SENSES A STATIC PRESSURE CONDITION BELOW

ITS SETPOINT OF -3 INWG (ADJUSTABLE), BOTH REMOTE EXHAUST FANS AND THE AH SUPPLY FAN SHALL BE DISABLED, AND

CONTROLS SHALL GO TO THEIR NORMAL POSITIONS UNTIL SAFETY THAT TRIPPED IS RESET MANUALLY.

B) IF THE PRESSURE SWITCH HIGH (PSH) AT THE DISCHARGE OF THE AH SUPPLY FAN SENSES A STATIC PRESSURE CONDITION ABOVE

ITS SETPOINT OF +3 INWG (ADJUSTABLE), BOTH REMOTE EXHAUST FANS AND THE AH SUPPLY FAN SHALL BE DISABLED, AND

CONTROLS SHALL GO TO THEIR NORMAL POSITIONS UNTIL SAFETY THAT TRIPPED IS RESET MANUALLY.

6) ALARMS: THE DDC GENERATES AN ALARM WHENEVER ANY OF THE FOLLOWING OCCURS:

A) THE SUPPLY FAN IS COMMANDED ON AND FAILS TO RUN.

B) THE SUPPLY FAN IS COMMANDED OFF BUT RUNS.

C) THE SUPPLY FAN SPEED DRIVE FAULT CONTACT IS ON.

D) EITHER EXHAUST FAN IS COMMANDED ON AND FAILS TO RUN.

E) EITHER EXHAUST FAN IS COMMANDED OFF BUT RUNS.

F) EITHER EXHAUST FAN SPEED DRIVE FAULT CONTACT IS ON.

G) THE LOW TEMPERATURE CUTOUT (FREEZESTAT) IS ACTIVATED.

H) ANY PRESSURE SWITCH IS ACTIVATED. PROVIDE UNIQUE ALARM FOR EACH PRESSURE SWITCH WITH UNIQUE TAGS.

I) THE SUPPLY AIR STATIC PRESSURE SENSOR FAILS (PRESSURE MORE THAN 10% ABOVE FINAL HIGH SETPOINT, ADJUSTABLE).

J) MIXED AIR TEMPERATURE SENSOR FAILS (LESS THAN 0°F, ADJUSTABLE OR MORE THAN 120°F, ADJUSTABLE).

K) MIXED AIR TEMPERATURE SENSOR FALLS BELOW 40°F, ADJUSTABLE.

L) DISCHARGE AIR TEMPERATURE SENSOR FAILS (LESS THAN 20°F, ADJUSTABLE OR MORE THAN 120°F, ADJUSTABLE).

M) RETURN AIR TEMPERATURE SENSOR FAILS (LESS THAN 20°F, ADJUSTABLE OR MORE THAN 120°F, ADJUSTABLE).

N) THE OUTSIDE AIRFLOW RATE IS LESS THAN 75% (ADJUSTABLE) OF MINIMUM OUTSIDE AIRFLOW SETPOINT, FOR A TIME PERIOD

GREATER THAN 15 MINUTES (ADJUSTABLE), WHEN OUTSIDE/RETURN AIR DAMPER OPERATION HAS BEEN ENABLED.

D. VARIABLE VOLUME AIR TERMINAL UNITS WITH REHEAT AND RADIANT PANELS:

1. DIRECT DIGITAL AIRFLOW CONTROLLER, DIFFERENTIAL PRESSURE SENSOR, AND ELECTRONIC DAMPER ACTUATOR SHALL BE

FURNISHED UNDER THIS SECTION BUT SHALL BE FACTORY MOUNTED BY THE TERMINAL UNIT MANUFACTURER. REHEAT AND RADIANT

PANEL CONTROL VALVES SHALL BE FURNISHED UNDER THIS SECTION BUT CAN BE FIELD INSTALLED.

2. SPACE COOLING AND HEATING SETPOINTS SHALL HAVE SEPARATE OCCUPIED AND UNOCCUPIED SETTINGS, AND CONTROLLER

SHALL AUTOMATICALLY SHIFT BETWEEN OCCUPIED AND UNOCCUPIED SETTINGS WHEN ASSOCIATED AH IS SHIFTED. SEE

UNOCCUPIED AND OCCUPIED SPACE SETPOINTS SECTIONS OF AH SEQUENCES.

3. IN PATIENT ROOMS, PRIVATE OFFICES, AND SIMILAR SPACES, SETPOINT SHALL BE ADJUSTABLE BY OCCUPANT AT SPACE

TEMPERATURE SENSOR BY PLUS OR MINUS 2-DEGREE FAHRENHEIT (ADJUSTABLE) AND AT OPERATOR WORKSTATION. IN PUBLIC

AREAS SETPOINT SHALL BE INACCESSIBLE. ALL SETPOINTS MAY BE OVERRIDDEN AT THE OPERATOR'S WORKSTATION.

4. CONTROLLER SHALL MAINTAIN SUPPLY AIR VOLUME SETTING REGARDLESS OF SYSTEM STATIC PRESSURE BY DIRECTLY

MEASURING AIR FLOW AND CONTROLLING UNIT DAMPER.

A) MAXIMUM AIR VOLUME SHALL BE PRESET TO EQUAL THE SUM OF ALL ATTACHED DIFFUSERS AND REGISTERS WHICH SHOULD

MATCH THE SCHEDULED MAXIMUM AIR VOLUME FOR EACH TERMINAL UNIT.

B) MINIMUM AIR VOLUME SHALL BE PRESET TO THE VOLUME LISTED IN SCHEDULE.

5. TEMPERATURE CONTROL:

A) CONTROLLER SHALL MODULATE AIR VOLUME BETWEEN MINIMUM AND MAXIMUM SETTINGS TO MAINTAIN SPACE

TEMPERATURE SETPOINT.

B) ON A CALL FOR COOLING, DAMPER SHALL MODULATE OPEN. BOTH REHEAT COIL AND RADIANT PANEL VALVES SHALL BE

CLOSED.

C) ON A CALL FOR HEATING, DAMPER MODULATES CLOSED TO MINIMUM POSITION. REHEAT VALVE MODULATES OPEN FIRST,

THEN ASSOCIATED (LINKED) PREHEAT VALVE IN SEQUENCE TO MAINTAIN SPACE TEMPERATURE SETPOINT.

D) TERMINAL REHEAT COIL CONTROL VALVE SHALL BE 2-WAY VALVES UNLESS OTHERWISE NOTED.

E) EACH RADIANT PANEL CONTROL VALVE SHALL BE 2-WAY VALVES UNLESS OTHERWISE NOTED, AND EACH RADIANT PANEL

SHALL HAVE ITS OWN DEDICATED CONTROL VALVE.

E. CONSTANT VOLUME AIR TERMINAL UNITS WITH REHEAT AND RADIANT PANELS:

1. DIRECT DIGITAL AIRFLOW CONTROLLER, DIFFERENTIAL PRESSURE SENSOR, AND ELECTRONIC DAMPER ACTUATOR SHALL BE

FURNISHED UNDER THIS SECTION BUT SHALL BE FACTORY MOUNTED BY THE TERMINAL UNIT MANUFACTURER. REHEAT AND RADIANT

PANEL CONTROL VALVES SHALL BE FURNISHED UNDER THIS SECTION BUT CAN BE FIELD INSTALLED. THERE ARE A FEW CAV

TERMINAL UNITS WITHOUT REHEAT AND/OR RADIANT PANELS.

2. SPACE COOLING AND HEATING SETPOINTS SHALL HAVE SEPARATE OCCUPIED AND UNOCCUPIED SETTINGS, AND CONTROLLER

SHALL AUTOMATICALLY SHIFT BETWEEN OCCUPIED AND UNOCCUPIED SETTINGS WHEN ASSOCIATED AH IS SHIFTED. SEE

UNOCCUPIED AND OCCUPIED SPACE SETPOINTS SECTIONS OF AH SEQUENCES.

3. IN PATIENT ROOMS, PRIVATE OFFICES, AND SIMILAR SPACES, SETPOINT SHALL BE ADJUSTABLE BY OCCUPANT AT SPACE

TEMPERATURE SENSOR BY PLUS OR MINUS 2-DEGREE FAHRENHEIT (ADJUSTABLE) AND AT OPERATOR WORKSTATION. IN PUBLIC

AREAS SETPOINT SHALL BE INACCESSIBLE. ALL SETPOINTS MAY BE OVERRIDDEN AT THE OPERATOR'S WORKSTATION.

4. CONTROLLER SHALL MAINTAIN SUPPLY AIR VOLUME SETTING REGARDLESS OF SYSTEM STATIC PRESSURE BY DIRECTLY

MEASURING AIR FLOW AND CONTROLLING UNIT DAMPER.

A) CONSTANT AIR VOLUME SHALL BE PRESET TO EQUAL THE SUM OF ALL ATTACHED DIFFUSERS AND REGISTERS WHICH

SHOULD MATCH THE SCHEDULED CONSTANT AIR VOLUME FOR EACH TERMINAL UNIT.

5. TEMPERATURE CONTROL:

A) CONTROLLER SHALL MODULATE DAMPER TO MAINTAIN CONSTANT AIR VOLUME TO MAINTAIN VENTILATION SETPOINT.

B) ON A CALL FOR COOLING, DAMPER MODULATE TO MAINTAIN CONSTANT AIR VOLUME SETPOINT. BOTH REHEAT COIL AND RADIANT

PANEL VALVES SHALL BE CLOSED.

C) ON A CALL FOR HEATING, DAMPER MODULATES TO MAINTAIN CONSTANT AIR VOLUME SETPOINT. REHEAT VALVE MODULATES OPEN

FIRST, THEN ASSOCIATED (LINKED) PREHEAT VALVE IN SEQUENCE TO MAINTAIN SPACE TEMPERATURE SETPOINT.

D) TERMINAL REHEAT COIL CONTROL VALVE SHALL BE 2-WAY VALVES UNLESS OTHERWISE NOTED.

E) EACH RADIANT PANEL CONTROL VALVE SHALL BE 2-WAY VALVES UNLESS OTHERWISE NOTED, AND EACH RADIANT PANEL SHALL

HAVE ITS OWN DEDICATED CONTROL VALVE.

NO SCALE

INPUT/OUTPUT SUMMARY

INPUTS OUTPUTS SYSTEM FEATURES

ANALOG GENERAL

MEASURED CALC DIGITAL ANALOG DIGITAL ALARMS PROGRAMS

System, Apparatus, or Area Point Description

Tem

pera

ture

Rel

. Hum

idity

Flow

Rat

e

Diff

. Pre

ssur

e

Sta

tic P

ress

u re

KW

Mot

or R

PM

Pre

ssur

e

Run

Tim

e

Ent

halp

y

Effi

cien

cy

Lb/H

r

KW

H

Sta

tus

Nor

mal

/Ala

rm

Sm

oke

Ala

rm

Hig

h S

tatic

Pre

ss.

Air

Flow

End

sw

itch

Low

Pre

ss. A

larm

Hig

h Le

vel A

larm

Low

Lev

el A

l arm

Flow

Sw

itch

Sta

tus

Dam

per P

osi ti

on

Val

ve P

ositi

o n

Mot

or S

peed

Set

Poi

nt A

dj

Off-

On

Ope

n-C

lose

Res

et

Failu

re

Hig

h V

alue

Low

Val

ue

Tim

e S

ched

u lin

g

Dem

and

Lim

iting

Ent

halp

y O

pt

Sm

oke

Cnt

Tren

d

Ala

rm In

stru

c t

Nig

ht S

et-b

ack

Mor

ning

War

m-u

p

Sta

tic P

ress

u re

Opt

.

Tem

p. R

eset

Opt

.

Lead

/Lag

Col

or G

raph

i c

Supplementary Notes

AHU-70 X X X X X X

Return Air X X X X

Exhaust Air Fan (EF- 37,41) X X X X

Outside Air X X

Outside Air Damper X X

Return Air Damper

Mixed Air X

Prefilter X

Cooling Coil X X

Supply Air Fan X X X X

SA Fan Variable Speed Drive X X X

Supply Air X X X X X

Smoke Dampers X X

AIR TERMINAL UNITS X X X X X

Supply Air X X X

Reheat X

Space X

RADIANT HEATING PANEL

Reheat

Space

KW

H

GP

M

WITH 4 INCH PIPING. SEE SHEET MP-404.2. REPLACE EXISTING 3 INCH HWS/R PIPING FROM TEE TOWARDS EAST CHASE

DIAGRAM NOTES:

Tota

lizat

ion

X X X

X

X

X

X

X X X X

X

X

XX X

NO SCALE

2

BAS (JOHNSON CONTROLS FACILITY EXPLORER).1. THE NEW HVAC SYSTEM CONTROLS SHALL BE COMPATABLE WITH THE EXISTING

NOTES FOR EXISTING/NEW CONTROL SYSTEM INTERFACE:

1

4

3. TIE EXISTING BRANCH PIPING INTO NEW 4 INCH RISER. SEE SHEET MP-406.4. END OF NEW 4 INCH RISER. TIE INTO EXISTING RISER BELOW NEW 6TH FLOOR

BRANCH.5. REPLACE EXISTING HWS VALVES WITH NEW COMBINATION BALANCING VALVE-

ISOLATION VALVE WITH MEMORY STOP. REPLACE EXISTING HWR VALVE WITHNEW ISOLATION VALVE. SEE SHEETS 401-406 FOR MORE DETAILS REGARDING

3

REPLACEMENT OF BALANCING VALVES.

1. TAB CONTRACTOR SHALL PERFORM A PRELIMINARY HOT WATER BALANCE

51 5

THE PRELIMINARY HOT WATER BALANCE REPORT SHALL BE ISSUED TO THE

AND RECORD FLOWS AT EACH EXISTING HOT WATER BALANCE VALVE BEFORE

SERVED ARE IN A MAX DESIGN FLOW FULL HEATING MODE OF OPERATION.IT IS REPLACED AS SHOWN ON RISER DIAGRAM WHEN HEATING SYSTEMS

RESIDENT ENGINEER FOR EVALUATION. AFTER NEW 4 INCH HOT WATER PIPE AND

BALANCE NEW HOT WATER VALVES TO MATCH FLOWS ON PRELIMINARY HOTNEW HOT WATER BALANCE VALVES ARE PROVIDED, TAB CONTRACTOR SHALL

WATER BALANCE REPORT OR TO NEW FLOW RATES AS DIRECTED BY THERESIDENT ENGINEER WHO EVALUATED THE PRELIMINARY REPORT.

NO SCALE

DIAGRAM NOTES:

1

1. REPLACE EXISTING AIR SEPARATOR WITH NEW LINE SIZE SPIROTHERM OR EQUAL COMBINATION AIR/DIRT SEPARATOR.PUMP SUCTION PIPING SHALL BE ADJUSTED TO ELEVATION THAT MATCHES WITH NEW AIR/DIRT SEPARATOR CONNECTIONS.

2. EXISTING FILTER/CHEMICAL TREATMENT SYSTEM TO BE DEMOLISHED BACK TO TAPS AT THE HWS PUMP DISCHARGE ANDTHE RELIEF VALVE. CHEMICAL BY-PASS FEEDER TO BE RETAINED AND PROVIDED TO THE VA.

3. NEW SHUTOFF VALVE AND CAPS TO BE INSTALLED AT EXISTING CHEMICAL TREATMENT TAPS FOR FUTURE INSTALLATIONOF CHEMICAL TREATMENT SYSTEM BY VA. INSULATE WHERE SHUTOFF VALVE/CAPS ARE ADDED AND WHERE INSULATIONIS DISTURBED ON EXISTING HWS PIPING.

2

3

3

1 5

1 5

1 5

1 5

1 5

1 5

1 5

1 5 51

51

51

51

51

51

X

EF Fan Variable Speed Drive X X X

X X

X

1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

10/05/18RESPONSIBLE CHARGE

10/05/18COVERING HVAC DESIGN

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/5

/2018 5

:57:5

3 P

M

MH-601

HVAC CONTROL AND DETAILS I

10/05/18 PP KGRevisions: Date:

SMOKE AND COMBINATION FIRE/SMOKE DAMPER SCHEDULE

MARK LOCATIONFAN

SYSTEM

SYSTEMAND/ORSERVICE

DUCT SIZEDUCT PRESSURE

CLASS REMARKS

IN [mm] IN WG [Pa]

FD-1 C6001 SF-70 AHU-70 24x8 [600 x 200] 3 [ 750 ] 2HR FIRE

FD-2 C6032 SF-70 AHU-70 24x8 [600 x 200] 3 [ 750 ] 2HR FIRE

FD-3 C6031 SF-70 AHU-70 8x8 [200 x 200] 3 [ 750 ] 2HR FIRE + SMOKE

FD-4 C6029 SF-70 AHU-70 24x8 [600 x 200] 3 [ 750 ] 2HR FIRE

FD-5 C7040 SF-70 AHU-70 20x16 [500 x 400] 3 [ 750 ] 2HR FIRE + SMOKE

FD-6 C6031 EF-37 AHU-70 20x10 [500 x 250] 3 [ 750 ] 2HR FIRE + SMOKE

FD-7 C6031 RF AHU-70 34x10 [850 x 250] 3 [ 750 ] 2HR FIRE

FD-8 C6029 RF AHU-70 34x10 [850 x 250] 3 [ 750 ] 2HR FIRE

FD-9 C7040 EF-41 AHU-70 20x10 [508 x 254] 3 [ 750 ] 2HR FIRE + SMOKE

AIR DEVICE SCHEDULE (SUPPLY)

MARK TYPE

AIR FLOWMAX APD

MOUNTING

PANEL/FRAME SIZE NECK SIZE

NC DAMPER FINISH REMARKSMIN MAXIN x IN [mm x mm] IN [mm ]

CFM [L/s] CFM [L/s] IN WG [Pa]

SD-1 SQUARE HIGH PERFORMANCE CONE 40 [ 19 ] 200 [ 94 ] 0.110 [ 28 ] CEILING 24 X 24 [ 600 X 600 ] 6 ø [ 150 ] 30 OBD WHITE 1

SD-2 SQUARE HIGH PERFORMANCE CONE 205 [ 97 ] 360 [ 170 ] 0.110 [ 28 ] CEILING 24 X 24 [ 600 X 600 ] 8 ø [ 200 ] 30 OBD WHITE 1

NOTES

1. PROVIDE SQUARE TO ROUND ADAPTER WHERE REQUIRED.

AIR DEVICE SCHEDULE (RETURN+EXHAUST)

MARK TYPE SIZE

AIR FLOWMAX APD

MOUNTING NC DAMPER FINISH REMARKSMIN MAX

CFM [L/s] CFM [L/s] IN WG [Pa]

RG-1 EGGCRATE 6X6 50 [ 24 ] 95 [ 45 ] 0.11 28 CEILING 20 OBD WHITE 1

RG-2 EGGCRATE 8X8 100 [ 47 ] 125 [ 59 ] 0.11 28 CEILING 20 OBD WHITE 1

RG-3 EGGCRATE 12X12 130 [ 61 ] 280 [ 130 ] 0.11 28 CEILING 20 OBD WHITE 1

RG-4 EGGCRATE 18X18 290 [ 140 ] 590 [ 280 ] 0.11 28 CEILING 20 OBD WHITE 1

RG-5 EGGCRATE 24X24 600 [ 280 ] 925 [ 440 ] 0.11 28 CEILING 20 OBD WHITE 1

EG-1 EGGCRATE 6X6 50 [ 24 ] 95 [ 45 ] 0.11 28 CEILING 20 OBD WHITE 1

EG-2 EGGCRATE 8X8 100 [ 47 ] 125 [ 59 ] 0.11 28 CEILING 20 OBD WHITE 1

EG-3 EGGCRATE 12X12 130 [ 61 ] 280 [ 130 ] 0.11 28 CEILING 20 OBD WHITE 1

EG-4 EGGCRATE 18X18 290 [ 140 ] 590 [ 280 ] 0.11 28 CEILING 20 OBD WHITE 1

EG-5 EGGCRATE 24X24 600 [ 280 ] 925 [ 440 ] 0.11 28 CEILING 20 OBD WHITE 1

NOTE

1. PROVIDE SQUARE TO ROUND ADAPTER WHERE REQUIRED

PUMP SCHEDULE

MARK LOCATION

AREAAND/ORBLDG

SERVED

SYSTEM AND/ORSERVICE

TYPE

CIRCULATING FLUIDMIN %EFF

ELECTRICAL MOTOR

REMARKSFLUID

FLOW HEAD TEMPERATURESP GR

NOMINAL POWERPHASE VOLT MAX RPM

SPEEDCONTROLGPM [L/s] FT [kPa] °F [°C] HP [kW]

P-1, P-2 PENTHOUSE ALL HEATING WATEREND

SUCTIONBUILDING HEATING

WATER150 [ 10 ] 50 [ 800 ] 180 [ 82 ] 0.975 73.5 5 [ 4 ] 3 230/460 1800 CONSTANT ----

VFD

S

TS

C CONTROLLER

CONTROL VALVE (2-WAY

OR 3-WAY-SEE PLANS

AND FLOW DIAGRAMS)

TEMPERATURE SENSOR

FZ-1

MD

MOTOR OPERATED SMOKE DAMPER

COIL (TYPE INDICATED)

LOW LIMIT THERMOSTAT

MOTOR OPERATED DAMPER

STATIC PRESSURE GAUGESP

SMOKE DETECTOR

SPACE TEMPERATURE SENSOR

CONTROL SYMBOLS

AIR FLOW SENSOR

VARIABLE FREQUENCY DRIVE

T

TEMPERATURE SENSOR

(AVERAGING STEM)

(RIGID STEM)

TS

STATIC PRESSURESPSSENSOR

DPGAUGEDIFFERENTIAL PRESSURE

ES

SD

END SWITCH

PSL

PSH

PRESSURE SWITCH HIGH

PRESSURE SWITCH LOW

AIR HANDLING UNIT

FILTERS COIL

CH

CH

R

NO SCALE AH-70

TEMPERED AIR

DP

TS-1

SUPPLYFAN

C

TS-2

SUPPLYAIR

COOLING

EXHAUSTAIR

ES

EXHAUSTFAN

RETURN AIR

C

S

MD

SD

VFD

C

STATICPRESSURESENSOR

PSH

FZ-1

C

MD

T

FROM AHU-1

AIR FLOW STATION

VFD

C

PSL

PSL-1

EXHAUST FANNO SCALE EF-37/EF-41

(NC)

(NC)

(NC)

(NC TO COIL)

TS

TS

SPS

TS

TS

REMOTE OUTSIDEOUTSIDE AIR

TEMPERATURESENSOR

SUPPLYAIR

ES

SD

S

(NC)

SUPPLYAIR

ES

SD

S

(NC)

DPS DIFFERENTIAL PRESSURE SENSOR

MD

DPS

C

ES

SD

S

(NC)

(FD-3&5)

(FD-3&5)

(FD-4)

(NO)

S

(FD-6&9)

ES SD

S

(NC)

(FD-7&8)

AIR FILTER SCHEDULE

MARK LOCATIONAREA AND/OR BLDG

SERVED

SYSTEMAND/ORSERVICE

MERVRATING

AIR FLOWAPD

HOUSINGTYPE

CARTRIDGES

INITIAL CHANGEOVER#

SIZEARRANGEMENT REMARKS

CFM [L/s] IN [mm] IN [mm] IN [mm]

PF-70A C7040C-WING, E, 6TH & 7TH

FLOORAHU-70 8 13000 [ 6100 ] 0.5 [ 13 ] 1.2 [ 30 ] SIDE 3 12 x 24 x 2 -----

PF-70B C7040C-WING, E, 6TH & 7TH

FLOORAHU-70 8 13000 [ 6100 ] 0.5 [ 13 ] 1.2 [ 30 ] SIDE 8 20 x 20 x 2 -----

AF-70A C7040C-WING, E, 6TH & 7TH

FLOORAHU-70 15 13000 [ 6100 ] 0.6 [ 15 ] 1 [ 25 ] SIDE 3 12 x 24 x 12 -----

AF-70B C7040C-WING, E, 6TH & 7TH

FLOORAHU-70 15 13000 [ 6100 ] 0.6 [ 15 ] 1 [ 25 ] SIDE 8 20 x 20 x 12 -----

CHILLED WATER COOLING COIL SCHEDULE

MARK LOCATIONAREA AND/OR BLDG

SERVED

SYSTEMAND/ORSERVICE

AIR FLOWMAX FACEVELOCITY

APDEAT LAT

TOTAL CAPACITY SENSIBLE CAPACITYCHILLED WATER

REMARKSDb Wb Db Wb FLOW EWT LWT WPD

CFM [L/s] FPM [M/s] IN WG [Pa] °F [°C] °F [°C] °F [°C] °F [°C] MBH [kW] MBH [kW] GPM [L/s] °F [°C] °F [°C] FT [M]

CC-70 C7040C-WING, E, 6TH & 7TH

FLOORAHU-70 13000 [ 6100 ] 481 [ 2 ] 0.45 [ 110 ] 68 [ 20 ] 60 [ 16 ] 54 [ 12 ] 53.4 [ 12 ] 209 [ 61 ] 188 [ 55 ] 42 [ 3 ] 44 [ 7 ] 54 [ 12 ] 10.9 [ 3 ] -----

FAN SCHEDULE

MARK LOCATIONAREA AND/OR BLDG

SERVED

SYSTEMAND/ORSERVICE

AIR FLOW TSP

FAN MOTOR ELECTRICAL

CONTROLSEQUENCE

REMARKSTYPE WHEEL CLASS

ARRANGEMENT,ROTATION, ANDDISCHARGE

DIAMETERMIN % EFF DRIVE

FAN MAXRPM

NOMINAL POWERPHASE VOLT RPM

SPEEDCONTROL

CFM [L/s] IN [Pa] IN [mm] BHP HP [kW]

SF-70 C7040C-WING, EAST, 6TH & 7TH

FLOORAHU-70 13000 [ 6100 ] 7.7 [ 1900 ] CENTRIFUGAL CF II PLENUM MANUF MANUF 66% DIRECT 3657 24 30 [ 22 ] 3 460 3600 VARIABLE 1,2

EF-37 EAST CHASE, 7TH FLOOR C-WING, EAST, 6TH FLOOR AHU-70 1770 [ 840 ] 0.9 [ 230 ] CENTRIFUGAL BI I INLINE MANUF MANUF 48% DIRECT 1725 0.5 1 [ 1 ] 3 460 1725 VARIABLE 1

EF-41 EAST CHASE, 8TH FLOOR C-WING, EAST, 7TH FLOOR AHU-70 2350 [ 1100 ] 1.6 [ 400 ] CENTRIFUGAL BI I INLINE MANUF MANUF 55% DIRECT 1725 1 2 [ 2 ] 3 460 1725 VARIABLE 1

NOTE

1. PROVIDE LOCKABLE PANEL WITH SINGLE POINT CONNECTION

2. FOUR (4) FANS TOTAL. HP DATA REFLECTS TOTAL OF ALL FOUR.

AIR HANDLING UNIT SCHEDULE

MARK LOCATION AREA AND/OR BLDG SERVED TYPE AIR FLOW

AIR FLOWSUPPLY FAN

MARKRETURN OR

RELIEF FAN MARKEXHAUSTFAN MARK

PREFILTERMARK

AFTER FILTERMARK

FINALFILTER MARK

HEATRECOVERY

MARK

PREHEATCOIL MARK

COOLINGCOIL MARK

REHEATCOIL

HUMIDIFIERMARK

REMARKSSUPPLY MIN OA RETURN

CFM [L/s] CFM [L/s] CFM [L/s]

AHU-70 C7040 C-WING, E, 6TH & 7TH FLOOR HORIZONTAL DRAW THRU VAV 13000 [ 6100 ] 4120 [ 1900 ] 8880 [ 4200 ] SF-70 N/A EF-37, EF-41 PF-70A/B AF-70 N/A N/A N/A CC-70 AT TU N/A ----

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

10/05/18RESPONSIBLE CHARGE

10/05/18COVERING HVAC DESIGN

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/5

/2018 5

:57:5

3 P

M

MH-602

HVAC CONTROL AND DETAILS II

10/05/18 PP KGRevisions: Date:

AHU-70 DUCT AIR TERMINAL UNIT SCHEDULE

MARK LOCATION

AREAAND/ORROOM

SERVED

SYSTEM AIRHANDLING

DUCT INLETSIZE

AIR FLOW HOT WATER HEATING COIL

PERIMETERSUPPLEMENTAL HEAT LINK

REMARKS90% EFFICIENT MAX MIN EAT EWT FLOW MAX WPD

PIPE RUNOUTSIZE TO COIL

MIN BTUH

IN CFM [L/s] CFM [L/s] CFM [L/s] °F °F GPM FT IN BTUH

VAV-1 C6001 C6001 AHU-70 10 x 8 1056 [ 500 ] 950 [ 450 ] 501 [ 240 ] 55 180 1.4 1 0.75 13,527 RP-01, RP-02, RP-03, RP-04 1,2,4,5

VAV-2 C6002 C6002 AHU-70 10 x 8 289 [ 140 ] 260 [ 120 ] 87 [ 41 ] 55 180 0.5 1 0.75 2,349 RP-05, RP-06 1,2,4,5

VAV-62 C6002 C6002A AHU-70 8 x 6 122 [ 58 ] 110 [ 52 ] 55 [ 26 ] 55 180 0.5 1 0.75 1,485 RP-07 1,2,4,5

VAV-5 C6006 C6006 AHU-70 8 x 6 189 [ 89 ] 170 [ 80 ] 169 [ 80 ] 55 180 0.5 1 0.75 4,563 NONE 1,2,4,5

VAV-6 C6007 C6007 AHU-70 10 x 8 722 [ 340 ] 650 [ 310 ] 249 [ 120 ] 55 180 0.7 1 0.75 6,723 RP-08, RP-09 1,2,4,5

VAV-7 C6007 C6008 AHU-70 10 x 8 611 [ 290 ] 550 [ 260 ] 164 [ 77 ] 55 180 0.5 1 0.75 4,428 RP-10, RP-11 1,2,4,5

VAV-9 C6-24 C6009 AHU-70 8 x 6 344 [ 160 ] 310 [ 150 ] 94 [ 44 ] 55 180 0.5 1 0.75 2,538 RP-12 1,2,4,5

VAV-10 C6-24 C6010 AHU-70 8 x 6 289 [ 140 ] 260 [ 120 ] 95 [ 45 ] 55 180 0.5 1 0.75 2,565 RP-13, RP-14 1,2,4,5

VAV-11 C6-24 C6011 AHU-70 8 x 6 122 [ 58 ] 110 [ 52 ] 55 [ 26 ] 55 180 0.5 1 0.75 1,485 RP-15 1,2,4,5

VAV-12 C6013 C6012 AHU-70 8 x 6 344 [ 160 ] 310 [ 150 ] 106 [ 50 ] 55 180 0.5 1 0.75 2,862 RP-16, RP-17 1,2,4,5

VAV-13 C6014 C6013 AHU-70 8 x 6 333 [ 160 ] 300 [ 140 ] 106 [ 50 ] 55 180 0.5 1 0.75 2,862 RP-18 1,2,4,5

VAV-14 C6015 C6014 AHU-70 8 x 6 344 [ 160 ] 310 [ 150 ] 103 [ 49 ] 55 180 0.5 1 0.75 2,781 RP-19 1,2,4,5

VAV-15 C6016 C6015 AHU-70 8 x 6 333 [ 160 ] 300 [ 140 ] 109 [ 51 ] 55 180 0.5 1 0.75 2,943 RP-20 1,2,4,5

VAV-16 C6-24 C6016 AHU-70 10 x 8 656 [ 310 ] 590 [ 280 ] 224 [ 110 ] 55 180 0.6 1 0.75 6,048 RP-21, RP-22 1,2,4,5

VAV-17 C6-23 C6017 AHU-70 8 x 6 89 [ 42 ] 80 [ 38 ] 64 [ 30 ] 55 180 0.5 1 0.75 1,728 NONE 1,2,4,5

VAV-18 C6019 C6019 AHU-70 10 x 8 811 [ 380 ] 730 [ 340 ] 443 [ 210 ] 55 180 1.2 1 0.75 11,961 RP-23, RP-24, RP-25, RP-26 1,2,4,5

CAV-21 C6-23 C6020 AHU-70 8 x 6 232 [ 110 ] 209 [ 99 ] 209 [ 99 ] 55 180 0.6 1 0.75 5,643 NONE 1,2,3,4

VAV-23 C6021 C6021 AHU-70 8 x 6 156 [ 74 ] 140 [ 66 ] 64 [ 30 ] 55 180 0.5 1 0.75 1,728 RP-27 1,2,4,5

VAV-25 C6020 C6022 AHU-70 8 x 6 200 [ 94 ] 180 [ 85 ] 93 [ 44 ] 55 180 0.5 1 0.75 2,511 RP-28 1,2,4,5

VAV-27 C6020 C6023 AHU-70 8 x 6 122 [ 58 ] 110 [ 52 ] 61 [ 29 ] 55 180 0.5 1 0.75 1,647 RP-29 1,2,4,5

VAV-29 C6024 C6024 AHU-70 8 x 6 156 [ 74 ] 140 [ 66 ] 74 [ 35 ] 55 180 0.5 1 0.75 1,998 RP-30, RP-31 1,2,4,5

VAV-28 C6025 C6025 AHU-70 8 x 6 244 [ 120 ] 220 [ 100 ] 128 [ 60 ] 55 180 0.5 1 0.75 3,456 RP-32, RP-33 1,2,4,5

VAV-26 C6020 C6026 AHU-70 8 x 6 211 [ 100 ] 190 [ 90 ] 94 [ 44 ] 55 180 0.5 1 0.75 2,538 RP-34 1,2,4,5

VAV-24 C6027 C6027 AHU-70 8 x 6 211 [ 100 ] 190 [ 90 ] 93 [ 44 ] 55 180 0.5 1 0.75 2,511 RP-35 1,2,4,5

VAV-22 C6029 C6028 AHU-70 8 x 6 211 [ 100 ] 190 [ 90 ] 92 [ 43 ] 55 180 0.5 1 0.75 2,484 RP-36 1,2,4,5

VAV-20 C6029 C6029 AHU-70 8 x 6 311 [ 150 ] 280 [ 130 ] 151 [ 71 ] 55 180 0.5 1 0.75 4,077 RP-37 1,2,4,5

VAV-19 C6-23 C6030 AHU-70 10 x 8 522 [ 250 ] 470 [ 220 ] 235 [ 110 ] 55 180 0.6 1 0.75 6,345 RP-38, RP-39 1,2,4,5

CAV-61 C6031 C6031 AHU-1 8 x 8 400 [ 190 ] 360 [ 170 ] 360 [ 170 ] 53 - - - - - NONE 1,3,5

VAV-3 C6-23 C6032 AHU-70 8 x 6 89 [ 42 ] 80 [ 38 ] 64 [ 30 ] 55 180 0.5 1 0.75 1,728 NONE 1,2,4,5

VAV-4 C6002 C6-23 AHU-70 8 x 6 189 [ 89 ] 170 [ 80 ] 167 [ 79 ] 55 180 0.5 1 0.75 4,509 NONE 1,2,4,5

VAV-8 C6008 C6-24 AHU-70 10 x 8 217 [ 100 ] 195 [ 92 ] 135 [ 64 ] 55 180 0.5 1 0.75 3,645 NONE 1,2,4,5

VAV-64 C6-25 C6-25 AHU-70 8 x 8 307 [ 140 ] 276 [ 130 ] 276 [ 130 ] 55 180 0.7 1 0.75 7,452 NONE 1,2,4,5

VAV-60 C7005 C7001 AHU-70 8 x 6 167 [ 79 ] 150 [ 71 ] 87 [ 41 ] 55 180 0.5 1 0.75 2,349 RP-40 1,2,4,5

VAV-59 C7005 C7003 AHU-70 8 x 6 233 [ 110 ] 210 [ 99 ] 145 [ 68 ] 55 180 0.5 1 0.75 3,915 RP-41, RP-42 1,2,4,5

VAV-58 C7005 C7005 AHU-70 8 x 6 689 [ 330 ] 620 [ 290 ] 303 [ 140 ] 55 180 0.8 1 0.75 8,181 RP-43, RP-44, RP-47 1,2,4,5

VAV-55 C7007 C7007 AHU-70 10 x 8 722 [ 340 ] 650 [ 310 ] 499 [ 240 ] 55 180 1.3 1 0.75 13,473 RP-48 1,2,4,5

VAV-56 C7007 C7007 AHU-70 8 x 6 156 [ 74 ] 140 [ 66 ] 108 [ 51 ] 55 180 0.5 1 0.75 2,916 RP-49 1,2,4,5

VAV-57 C7007 C7009/C7-11 AHU-70 8 x 6 333 [ 160 ] 300 [ 140 ] 198 [ 93 ] 55 180 0.5 1 0.75 5,346 RP-45, RP-46 1,2,4,5

VAV-49 C7011 C7011 AHU-70 8 x 6 291 [ 140 ] 262 [ 120 ] 102 [ 48 ] 55 180 0.5 1 0.75 2,754 RP-68 1,2,4,5

VAV-50 C7012 C7012 AHU-70 8 x 6 300 [ 140 ] 270 [ 130 ] 103 [ 49 ] 55 180 0.5 1 0.75 2,781 RP-69 1,2,4,5

VAV-51 C7013 C7013/C7014 AHU-70 8 x 6 444 [ 210 ] 400 [ 190 ] 114 [ 54 ] 55 180 0.5 1 0.75 3,078 RP-70 1,2,4,5

VAV-52 C7015 C7015 AHU-70 8 x 6 300 [ 140 ] 270 [ 130 ] 105 [ 50 ] 55 180 0.5 1 0.75 2,835 RP-71 1,2,4,5

VAV-53 C7016 C7016 AHU-70 8 x 6 311 [ 150 ] 280 [ 130 ] 108 [ 51 ] 55 180 0.5 1 0.75 2,916 RP-72, RP-73 1,2,4,5

VAV-48 C7017 C7017 AHU-70 8 x 6 278 [ 130 ] 250 [ 120 ] 105 [ 50 ] 55 180 0.5 1 0.75 2,835 RP-75, RP-76 1,2,4,5

VAV-47 C7018 C7018 AHU-70 8 x 6 178 [ 84 ] 160 [ 76 ] 100 [ 47 ] 55 180 0.5 1 0.75 2,700 RP-77 1,2,4,5

VAV-46 C7019 C7019 AHU-70 8 x 6 178 [ 84 ] 160 [ 76 ] 105 [ 50 ] 55 180 0.5 1 0.75 2,835 RP-78 1,2,4,5

VAV-45 C7020 C7020 AHU-70 8 x 6 278 [ 130 ] 250 [ 120 ] 103 [ 49 ] 55 180 0.5 1 0.75 2,781 RP-79 1,2,4,5

VAV-44 C7021 C7021 AHU-70 8 x 6 278 [ 130 ] 250 [ 120 ] 98 [ 46 ] 55 180 0.5 1 0.75 2,646 RP-80 1,2,4,5

VAV-43 C7022 C7022 AHU-70 8 x 6 278 [ 130 ] 250 [ 120 ] 92 [ 43 ] 55 180 0.5 1 0.75 2,484 RP-81 1,2,4,5

VAV-31 C7026 C7026 AHU-70 8 x 6 233 [ 110 ] 210 [ 99 ] 126 [ 59 ] 55 180 0.5 1 0.75 3,402 RP-50 1,2,4,5

VAV-32 C7027 C7027 AHU-70 8 x 6 156 [ 74 ] 140 [ 66 ] 92 [ 43 ] 55 180 0.5 1 0.75 2,484 RP-51 1,2,4,5

VAV-33 C7028 C7028 AHU-70 8 x 6 156 [ 74 ] 140 [ 66 ] 92 [ 43 ] 55 180 0.5 1 0.75 2,484 RP-52 1,2,4,5

VAV-35 C7029 C7029 AHU-70 8 x 6 156 [ 74 ] 140 [ 66 ] 92 [ 43 ] 55 180 0.5 1 0.75 2,484 RP-53 1,2,4,5

VAV-38 C7030 C7030 AHU-70 8 x 6 289 [ 140 ] 260 [ 120 ] 136 [ 64 ] 55 180 0.5 1 0.75 3,672 RP-54, RP-55 1,2,4,5

VAV-40 C7031 C7031 AHU-70 8 x 6 156 [ 74 ] 140 [ 66 ] 92 [ 43 ] 55 180 0.5 1 0.75 2,484 RP-56 1,2,4,5

VAV-41 C7032 C7032 AHU-70 8 x 6 189 [ 89 ] 170 [ 80 ] 92 [ 43 ] 55 180 0.5 1 0.75 2,484 RP-57, RP-58 1,2,4,5

VAV-42 C7033 C7033 AHU-70 8 x 6 267 [ 130 ] 240 [ 110 ] 115 [ 54 ] 55 180 0.5 1 0.75 3,105 RP-60, RP-61 1,2,4,5

VAV-39 C7-9 C7035 AHU-70 8 x 6 311 [ 150 ] 280 [ 130 ] 186 [ 88 ] 55 180 0.5 1 0.75 5,022 RP-62, RP-63 1,2,4,5

VAV-36 C7-9 C7037 AHU-70 8 x 6 311 [ 150 ] 280 [ 130 ] 176 [ 83 ] 55 180 0.5 1 0.75 4,752 RP-65 1,2,4,5

VAV-37 C7-9 C7037A/C7-9 AHU-70 8 x 6 244 [ 120 ] 220 [ 100 ] 115 [ 54 ] 55 180 0.5 1 0.75 3,105 RP-59, RP-64 1,2,4,5

VAV-34 C7039 C7039 AHU-70 8 x 6 222 [ 100 ] 200 [ 94 ] 85 [ 40 ] 55 180 0.5 1 0.75 2,295 RP-66, RP-67 1,2,4,5

CAV-65 C7040 C7040 AHU-70 6 x 8 222 [ 100 ] 200 [ 94 ] 200 [ 94 ] 53 - - - - - NONE 1,3,5

CAV-54 C7-10 C7-10 AHU-70 10 x 8 454 [ 210 ] 409 [ 190 ] 409 [ 190 ] 55 180 1.1 1 0.75 11,043 RP-74 1,3,4,5

VAV-30 C7-9 C7-9 AHU-70 8 x 6 329 [ 160 ] 296 [ 140 ] 229 [ 110 ] 55 180 0.6 1 0.75 6,183 NONE 1,2,4,5

NOTES

1. NO ADDITIONAL SOUND ATTENUATION REQUIRED.

2. CONTROL TYPE IS VAV; DISCHARGE AIR TEMPURATURE MAX 80°F

3. CONTROL TYPE IS CAV; DISCHARGE AIR TEMPURATURE MAX 80°F

4. REHEAT BY HOT WATER

5. VA DESIRES BOX EFFICIENCY BETWEEN 75% AND 90%. BOX EFFICIENCY EXAMPLE: 950 CFM/0.90 = 1056 CFM < VAV-1 BOX AIRFLOW RANGE SELECTION < 950 CFM/0.75 = 1267 CFMCHECKS: 0.90 X 1056 CFM = 950 CFM AND 0.75 x 1267 CFM = 950

CFM. ALSO 950/1056 = 0.90 AND 950/1267 = 0.75. SET UP VAV-1 BOX CAPABLE OF 1056 CFM TO 1267 CFM AT 950 CFM.

6. SIZE BOXES BASED OM 90% EFFICIENT AIRFLOW BUT BALANCE BOX AT MAX AIRFLOW.

RADIANT CEILING PANEL SCHEDULE (HYDRONIC )

MARKROOM

LOCATIONAREA SERVED

PANEL SIZE

HEATING

REMARKSHEATING CAPACITY EWT LWTHOT WATERFLOWRATE

WPD

IN [mm] BTUH [W] °F [°C] °F [°C] GPM [L/m] FT [kPa]

RP-1 C6001 LEARNERS 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10Basis: Sigma SLC,

Typical1-PASS

RP-2 C6001 LEARNERS 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-3 C6001 LEARNERS 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-4 C6001 LEARNERS 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-5 C6002 MD OFFICES 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-6 C6002 MD OFFICES 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-7 C6003 CHIEF 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-8 C6005 CONF RM 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-9 C6005 CONF RM 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-10 C6008 PHYS 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-11 C6008 PHYS 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-12 C6009 LEARNERS 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-13 C6010 NP 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-14 C6010 NP 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-15 C6011 CHIEF 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-16 C6012 RN 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-17 C6012 RN 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-18 C6013 LEARNERS 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-19 C6014 PHYS 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-20 C6015 MD OFFICE 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-21 C6016 MD OFFICES 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-22 C6016 MD OFFICES 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-23 C6019 MSAs 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-24 C6019 MSAs 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-25 C6019 MSAs 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-26 C6019 MSAs 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-27 C6021 BUS MNGR 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-28 C6022 CONFERENCE 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-29 C6023 PRACTICE MNGR 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-30 C6024 CHIEF 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-31 C6024 CHIEF 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-32 C6025 CHIEF 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-33 C6025 CHIEF 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-34 C6026 N CHIEF 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-35 C6027 N CHIEF 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-36 C6028 MSA SUPV 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-37 C6029 PSA 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-38 C6030 MD OFFICE 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-39 C6030 MD OFFICE 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-40 C7001 LOCKERS 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-41 C7003 LOCKERS 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-42 C7003 LOCKERS 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-43 C7005 BREAK RM/MAIL RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-44 C7005 BREAK RM/MAIL RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-45 C7-9 CORRIDOR 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-46 C7-9 CORRIDOR 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-47 C7007 WAITING ROOM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-48 C7007 WAITING ROOM 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-49 C7007 WAITING ROOM 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-50 C7026 TEAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-51 C7027 EXAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-52 C7028 EXAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-53 C7029 EXAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-54 C7030 TEAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-55 C7030 TEAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-56 C7031 EXAM RM 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-57 C7032 EXAM RM 48 X 24 [ 1219 X 610 ] 1856 [ 540 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.16 0.50 8-PASS

RP-58 C7032 EXAM RM 48 X 24 [ 1219 X 610 ] 1856 [ 540 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.16 0.50 8-PASS

RP-59 C7-11 CORRIDOR 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-60 C7033 EXAM RM 48 X 24 [ 1219 X 610 ] 1856 [ 540 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.16 0.50 8-PASS

RP-61 C7033 EXAM RM 48 X 24 [ 1219 X 610 ] 1856 [ 540 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.16 0.50 8-PASS

RP-62 C7035 EXAM-PROC 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-63 C7035 EXAM-PROC 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-64 C7038 TOILET 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-65 C7037 EXAM-PROC 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-66 C7039 CLEAN STORAGE 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-67 C7039 CLEAN STORAGE 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-68 C7011 EXAM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-69 C7012 EXAM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-70 C7013 TEAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-71 C7015 EXAM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-72 C7016 EXAM 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-73 C7016 EXAM 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-74 C7-10 CORRIDOR 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-75 C7017 EXAM 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-76 C7017 EXAM 48 X 24 [ 1219 X 610 ] 1556 [ 460 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-77 C7018 TEAM RM 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-78 C7019 EXAM 48 X 6 [ 1219 X 152 ] 516 [ 150 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.02 0.10 1-PASS

RP-79 C7020 EXAM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-80 C7021 TEAM RM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

RP-81 C7022 EXAM 48 X 12 [ 1219 X 305 ] 944 [ 280 ] 165 [ 74 ] 145 [ 63 ] 0.5 1.90 0.08 0.20 4-PASS

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/6

/2018 3

:19:1

1 P

M

MH-603

MECHANICAL SCHEDULE I

10/05/18 PP KGRevisions: Date:

ROOM AIR BALANCE SCHEDULE

ROOM NO ROOM NAMEAIR

HANDLINGUNIT NO

TERMINAL UNITINDIVIDUALROOM TEMP

CONTROL

SUPPLY RETURN OR EXHAUSTROOM AIR

FLOW ROOM AIRBALANCE

NET INFILTRATIONNET

EXFILTRATIONREMARKSROOM AIR FLOW # OF AIR

DEVICESAIR DEVICE MARK

SUPPLYFAN

RETURN OREXHAUST

(R/E)

ROOM AIR FLOW # OF AIRDEVICES

AIR DEVICE MARK

RETURNOR

EXHAUSTFANCFM L/S CFM L/S CV VAV CFM [L/s] CFM [L/s]

C6001 LEARNERS AHU-70 VAV-1 Y 950 [ 450 ] 4 SD-2 SF-70 R 950 [ 450 ] 1 RG-5 X 0 0 [ ] 0 [ ] - - - -

C6002 MD OFFICES AHU-70 VAV-2 Y 260 [ 120 ] 3 SD-1 SF-70 R 260 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C6002A CHIEF AHU-70 VAV-62 Y 110 [ 52 ] 1 SD-1 SF-70 R 110 [ 52 ] 1 RG-2 X 0 0 [ ] 0 [ ] - - - -

C6004 TLT RM N/A N/A N 0 [ ] 0 N/A N/A E 75 [ 35 ] 1 EG-1 EF-37 X - - 75 [ 35 ] 0 [ ] - - - -

C6005 TLT RM N/A N/A N 0 [ ] 0 N/A N/A E 75 [ 35 ] 1 EG-1 EF-37 X - - 75 [ 35 ] 0 [ ] - - - -

C6006 BREAK RM AHU-70 VAV-5 Y 170 [ 80 ] 1 SD-1 SF-70 E 270 [ 130 ] 1 EG-3 EF-37 X - 100 [ 47 ] 0 [ ] - - - -

C6007 CONF RM AHU-70 VAV-6 Y 650 [ 310 ] 3 SD-2 SF-70 R 650 [ 310 ] 1 RG-5 X 0 0 [ ] 0 [ ] - - - -

C6008 PHYS AHU-70 VAV-7 Y 550 [ 260 ] 2 SD-2 SF-70 R 550 [ 260 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -

C6009 LEARNERS AHU-70 VAV-9 Y 310 [ 150 ] 1 SD-2 SF-70 R 310 [ 150 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -

C6010 NP AHU-70 VAV-10 Y 260 [ 120 ] 1 SD-2 SF-70 R 260 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C6011 CHIEF AHU-70 VAV-11 Y 110 [ 52 ] 1 SD-1 SF-70 R 110 [ 52 ] 1 RG-2 X 0 0 [ ] 0 [ ] - - - -

C6012 RN AHU-70 VAV-12 Y 310 [ 150 ] 1 SD-2 SF-70 R 310 [ 150 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -

C6013 LEARNERS AHU-70 VAV-13 Y 300 [ 140 ] 1 SD-2 SF-70 R 300 [ 140 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -

C6014 PHYS AHU-70 VAV-14 Y 310 [ 150 ] 1 SD-2 SF-70 R 310 [ 150 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -

C6015 MD OFFICE AHU-70 VAV-15 Y 300 [ 140 ] 1 SD-2 SF-70 R 300 [ 140 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -

C6016 MD OFFICES AHU-70 VAV-16 Y 590 [ 280 ] 2 SD-2 SF-70 R 590 [ 280 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -

C6017 MD OFFICE AHU-70 VAV-17 Y 80 [ 38 ] 1 SD-2 SF-70 R 80 [ 38 ] 1 RG-1 X 0 0 [ ] 0 [ ] - - - -

C6018 MECH RM N/A N/A N 0 [ ] 1 SD-2 AHU-1 N/A 0 [ ] 0 0 0 [ ] 0 [ ] - - - -

C6019 MSAs AHU-70 VAV-18 Y 730 [ 340 ] 4 SD-1 SF-70 R 730 [ 340 ] 2 RG-4 X 0 0 [ ] 0 [ ] - - - -

C6020 VESTIBULE AHU-70 VAV-21 Y 100 [ 47 ] 1 SD-2 SF-70 N/A 0 [ ] 0 X + 0 [ ] 100 [ 47 ] - - - -

C6021 BUS MNGR AHU-70 VAV-23 Y 140 [ 66 ] 1 SD-1 SF-70 R 140 [ 66 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C6022 CONFERENCE AHU-70 VAV-25 Y 180 [ 85 ] 1 SD-1 SF-70 R 180 [ 85 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C6023 PRACTICE MNGR AHU-70 VAV-27 Y 110 [ 52 ] 1 SD-1 SF-70 R 110 [ 52 ] 1 RG-2 X 0 0 [ ] 0 [ ] - - - -

C6024 CHIEF AHU-70 VAV-29 Y 140 [ 66 ] 1 SD-1 SF-70 R 140 [ 66 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C6025 CHIEF AHU-70 VAV-28 Y 220 [ 100 ] 1 SD-2 SF-70 R 220 [ 100 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C6026 N CHIEF AHU-70 VAV-26 Y 190 [ 90 ] 1 SD-1 SF-70 R 190 [ 90 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C6027 N CHIEF AHU-70 VAV-24 Y 190 [ 90 ] 1 SD-1 SF-70 R 190 [ 90 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C6028 MSA SUPV AHU-70 VAV-22 Y 190 [ 90 ] 1 SD-1 SF-70 R 190 [ 90 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C6029 PSA AHU-70 VAV-20 Y 280 [ 130 ] 1 SD-2 SF-70 R 280 [ 130 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C6030 MD OFFICE AHU-70 VAV-19 Y 470 [ 220 ] 2 SD-2 SF-70 R 470 [ 220 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -

C6031 MECH RM AHU-1 VAV-61 Y 360 [ 170 ] 1 SD-2 AHU-1 E 360 [ 170 ] 1 EG-4 EF-37 X 0 0 [ ] 0 [ ] FAN POWERED VAV

C6032 MD OFFICE AHU-70 VAV-3 Y 80 [ 38 ] 1 SD-1 SF-70 E 80 [ 38 ] 1 EG-1 EF-37 X 0 0 [ ] 0 [ ] - - - -

C6-23 CORRIDOR AHU-70 VAV-4 Y 170 [ 80 ] 1 SD-1 SF-70 E 1500 [ 710 ] 2 EG-5 EF-37 X + 1330 [ 630 ] 0 [ ] - - - -

C6-24 CORRIDOR AHU-70 VAV-8 Y 195 [ 92 ] 2 SD-1 SF-70 R 145 [ 68 ] 1 RG-3 X + 0 [ ] 50 [ 24 ] - - - -

C6-25 CORRIDOR AHU-70 VAV-64 Y 100 [ 47 ] 1 SD-1 SF-70 N/A 0 [ ] 0 0 [ ] 100 [ 47 ] - - - -

C7001 LOCKERS AHU-70 VAV-60 Y 150 [ 71 ] 1 SD-1 SF-70 E 220 [ 100 ] 1 EG-3 EF-41 X - 70 [ 33 ] 0 [ ] - - - -

C7001A STAFF TLT N/A N/A N 0 [ ] 0 N/A N/A E 75 [ 35 ] 1 EG-1 EF-41 X - - 75 [ 35 ] 0 [ ] - - - -

C7003 LOCKERS AHU-70 VAV-59 Y 210 [ 99 ] 1 SD-1 SF-70 E 280 [ 130 ] 1 EG-3 EF-41 X - 70 [ 33 ] 0 [ ] - - - -

C7003A STAFF TLT N/A N/A N 0 [ ] 0 N/A N/A E 75 [ 35 ] 1 EG-1 EF-41 X - - 75 [ 35 ] 0 [ ] - - - -

C7005BREAK RM/MAIL

RMAHU-70 VAV-58 Y 620 [ 290 ] 2 SD-2 SF-70 E+R 705 [ 330 ] 2 RG-3, EG-4 EF-41 X - 85 [ 40 ] 0 [ ] - - - -

C7006 HSKP N/A N/A N 0 [ ] 0 N/A N/A E 75 [ 35 ] 1 EG-1 EF-41 X - - 75 [ 35 ] 0 [ ] - - - -

C7007 WAITING ROOM AHU-70 VAV-55, VAV-56 Y 790 [ 370 ] 3 SD-1, SD-2, SD-2 SF-70 E+R 900 [ 420 ] 2 RG-5, EG-2 EF-41 X - 110 [ 52 ] 0 [ ] - - - -

C7008 PAT TLT N/A N/A N 0 [ ] 0 N/A SF-70 E 75 [ 35 ] 1 EG-1 EF-41 X - - 75 [ 35 ] 0 [ ] - - - -

C7009 RECEPT AHU-70 VAV-57 Y 200 [ 94 ] 1 SD-1 SF-70 N/A 0 [ ] 0 X 0 0 [ ] 200 [ 94 ] - - - -

C7010 CHECK OUT AHU-70 N/A N 0 N/A N/A R 200 [ 94 ] 1 RG-3 - - - -

C7011 EXAM AHU-70 VAV-49 Y 262 [ 120 ] 1 SD-2 SF-70 R 262 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7012 EXAM AHU-70 VAV-50 Y 270 [ 130 ] 1 SD-2 SF-70 R 270 [ 130 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7013 TEAM RM AHU-70 VAV-51 Y 350 [ 170 ] 1 SD-2 SF-70 R 350 [ 170 ] 1 RG-4 X 0 0 [ ] 0 [ ] - - - -

C7014 TLT RM AHU-70 VAV-51 Y 50 [ 24 ] 0 SD-1 SF-70 E 100 [ 47 ] 1 EG-13 X - - 50 [ 24 ] 0 [ ] - - - -

C7015 EXAM AHU-70 VAV-52 Y 270 [ 130 ] 1 SD-2 SF-70 R 270 [ 130 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7016 EXAM AHU-70 VAV-53 Y 280 [ 130 ] 1 SD-2 SF-70 R 280 [ 130 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7017 EXAM AHU-70 VAV-48 Y 250 [ 120 ] 1 SD-2 SF-70 R 250 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7018 TEAM RM AHU-70 VAV-47 Y 160 [ 76 ] 1 SD-1 SF-70 R 160 [ 76 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7019 EXAM AHU-70 VAV-46 Y 160 [ 76 ] 1 SD-2 SF-70 R 160 [ 76 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7020 EXAM AHU-70 VAV-45 Y 250 [ 120 ] 1 SD-2 SF-70 R 250 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7021 TEAM RM AHU-70 VAV-44 Y 250 [ 120 ] 1 SD-2 SF-70 R 250 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7022 EXAM AHU-70 VAV-43 Y 250 [ 120 ] 1 SD-2 SF-70 R 250 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7023 STOR N/A N/A N 0 [ ] 0 N/A N/A N/A 0 [ ] 0 0 [ ] 0 [ ] - - - -

C7024 ELEC N/A N/A N 0 [ ] 0 N/A N/A N/A 0 [ ] 0 - - 0 [ ] 0 [ ] - - - -

C7025 SOILED HOLDING N/A N/A N 0 [ ] 0 N/A N/A E 210 [ 99 ] 1 EG-3 EF-41 x N/A 210 [ 99 ] 0 [ ] - - - -

C7026 TEAM RM AHU-70 VAV-31 Y 210 [ 99 ] 1 SD-1 SF-70 R 210 [ 99 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7027 EXAM RM AHU-70 VAV-32 Y 140 [ 66 ] 1 SD-1 SF-70 R 140 [ 66 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7028 EXAM RM AHU-70 VAV-33 Y 140 [ 66 ] 1 SD-1 SF-70 R 140 [ 66 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7029 EXAM RM AHU-70 VAV-35 Y 140 [ 66 ] 1 SD-1 SF-70 R 140 [ 66 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7030 TEAM RM AHU-70 VAV-38 Y 260 [ 120 ] 1 SD-2 SF-70 R 260 [ 120 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7031 EXAM RM AHU-70 VAV-40 Y 140 [ 66 ] 1 SD-1 SF-70 R 140 [ 66 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7032 EXAM RM AHU-70 VAV-41 Y 170 [ 80 ] 1 SD-1 SF-70 R 170 [ 80 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7033 EXAM RM AHU-70 VAV-42 Y 240 [ 110 ] 1 SD-2 SF-70 R 240 [ 110 ] 1 RG-3 X 0 0 [ ] 0 [ ] - - - -

C7034 STOR N/A N/A N 0 [ ] 0 N/A N/A N/A 0 [ ] 0 0 [ ] 0 [ ] - - - -

C7035 EXAM/PROC ROOM AHU-70 VAV-39 Y 280 [ 130 ] 2 SD-1 SF-70 E+R 350 [ 170 ] 2 RG-3, EG-2 EF-41 X 0 70 [ 33 ] 0 [ ] - - - -

C7036 PAT TLT N/A N/A N 0 [ ] 0 N/A SF-70 E 75 [ 35 ] 1 EG-1 EF-41 X - - 75 [ 35 ] 0 [ ] - - - -

C7037 EXAM/PROC AHU-70 VAV-36 Y 280 [ 130 ] 1 SD-2 SF-70 E+R 350 [ 170 ] 2 RG-3, EG-2 EF-41 X 0 70 [ 33 ] 0 [ ] - - - -

C7037A PAT TLT N/A VAV-37 N 70 [ 33 ] 1 SD-1 SF-70 E 120 [ 57 ] 1 EG-2 EF-41 X - - 50 [ 24 ] 0 [ ] - - - -

C7039 CLEAN STORAGE AHU-70 VAV-34 N 200 [ 94 ] 1 SD-1 SF-70 R 120 [ 57 ] 1 RG-2 X + 0 [ ] 80 [ 38 ] - - - -

C7040 MECH RM AHU-70 VAV-65 Y 200 [ 94 ] 1 SD-1 SF-70 R 200 [ 94 ] 1 RG-3 X 0 0 [ ] 0 [ ] FAN POWERED VAV

C7-08 CORRIDOR N/A N/A N/A 0 [ ] N/A N/A N/A 0 - - - -

C7-09 CORRIDOR AHU-70 VAV-30,VAV-37 Y 300 [ 140 ] 2 SD-2 SF-70 R 250 [ 120 ] 1 RG-3 X + 0 [ ] 50 [ 24 ] - - - -

C7-10 CORRIDOR AHU-70 VAV-54 Y 190 [ 90 ] 1 SD-2 SF-70 R 140 [ 66 ] 1 RG-3 X + 0 [ ] 50 [ 24 ] - - - -

C7-11 CORRIDOR AHU-70 VAV-57 Y 100 [ 47 ] 1 SD-1 SF-70 N/A 0 [ ] 0 X + 0 [ ] 100 [ 47 ] - - - -

NOTES

1. ROOMS OR AREAS DO NOT HAVE INDIVIDUAL HUMIDITY CONTROL UNLESS NOTED.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

10/05/18RESPONSIBLE CHARGE

10/05/18COVERING HVAC DESIGN

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/5

/2018 5

:57:5

4 P

M

MH-604

MECHANICAL SCHEDULE II

10/05/18 PP KGRevisions: Date:

C-6144

C6-25

C6001

C6002

C6002A

C6032

C6031

C6006

C6004C6005

C6007C6008

C6009C6010

C6011

C6012C6013

C6014C6015

C6016

C6-24

C6017

S2-6

C6030

C6029

C6019

C6028

C6021

C6027C6022

C6026

C6023

C6025

C6024

2 1/2" HWS

2 1/2" HWR

(E) 3" HWS/RRISERS

RADIANT CEILINGHEATING PANEL (TYP.)

RADIANT CEILINGHEATING PANEL (TYP)

RADIANT CEILINGHEATING PANEL (TYP)

1 1/2" HWS/R

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

1 1/2" HWS/R

3/4" HWS/R

1 1/2" HWS/R

3/4" HWS/R

1 1/2" HWS/R

2" HWS/R

1 1/2" HWS/R

3/4" HWS/R

1 1/2" HWS/R

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

RP-02

RP-03

RP-04

RP-05

RP-06

RP-07

RP-01

RP-08 RP-09

RP-10 RP-11 RP-12RP-13

RP-14

1 1/2" HWS/R

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

RP-15

RP-16

RP-17RP-20 RP-19RP-18RP-21RP-22

RP-23

RP-24

RP-25

RP-26

RP-27

RP-28

RP-29

RP-30

RP-31

RP-32

RP-33

RP-34

RP-35

RP-36

RP-37

RP-38

RP-39

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R

VAV-1

VAV-2

VAV-3

VAV-4

VAV-5

VAV-6

VAV-7

VAV-8

VAV-9

VAV-10

VAV-12

VAV-13

VAV-14

VAV-15

VAV-16

VAV-17

VAV-18

CAV-21

VAV-23

VAV-27

VAV-26

VAV-24

VAV-22VAV-20

VAV-19

VAV-11

VAV-25

VAV-29VAV-28

3

1

TYP.

TYP.

2

TYP.

CAV-61

4

4

4

VAV-62

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

TT

T

T

T

T

T

T

T

T

TT

T T

T

2

MP-106

VAV-64

T

3/4" HWS/R

3/4" HWS/R

Level 6_770-5.2558' - 5 1/4"

Level 7_781-5.2569' - 5 1/4"

Level 7_781-5.2569' - 5 1/4"

2-1/2" HWS/R

4" HWR4" HWS

EXISTING HWREXISTING HWS

A. EXISTING WORK TO REMAIN AS INDICATED WITH LIGHT LINEWEIGHT.

B. NEW WORK IS INDICATED WITH HEAVY LINE WEIGHT.

C. REMOVE ALL HANGERS, SUPPORTS, TUBING, AND CONTROLDEVICES ASSOCIATED WITH EQUIPMENT TO BE REMOVED.

D. COORDINATE ALL SYSTEM OUTAGES WITH OWNER.

E. ASBESTOS ON EXISTING PIPING, DUCT, AND EQUIPMENTSHALL BE REMOVED BACK TO MAIN BY ABATEMENTCONTRACTOR AND NEEDS TO BE RE-INSULATED BY THEMECHANICAL CONTRACTOR. WORK TO BE COORDINATEDWITH ABATEMENT CONTRACTOR.

F. LOCATE BALANCE DAMPERS SO THEY CAN BE ACCESSEDTHROUGH CEILING TILE OR WITH REMOTE BALANCE DAMPERADJUSTMENT DEVICE.

G. INSTALL ALL EQUIPMENT AND ACCESSORIES IN ACCORDANCEWITH MANUFACTURERS’ RECOMMENDATIONS, CONTRACTDOCUMENTS, AND APPLICABLE CODES AND REGULATIONS.

H. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORKWITH OTHER DISCIPLINES: ARCHITECTURAL, PLUMBING,ELECTRICAL, ETC., SHOWN ON OTHER CONTRACTRDOCUMENTS.

I. ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICALEQUIPMENT AND PIPING INSULATION IS APPLIED.

J. LOCATE ALL TEMPERATURE, PRESSURE, AND FLOWMEASURING DEVICES IN ACCESSIBLE LOCATIONS WITHSTRAIGHT SECTION OF PIPE OR DUCT UP AND DOWNSTREAMAS RECOMMENDED BY THE MANUFACTURER FOR GOODPERFORMANCE.

K. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS ORREQUIRED BY THE SPECIFICATIONS NOT DEFINITELY FIXED BYDIMENSIONS ARE APPROXIMATE ONLY. THE EXACT LOCATIONSNECESSARY TO SECURE THE BEST RESULTS MUST BEDETERMINED BY THE PROJECT SITE CONDITIONS AND SHALLHAVE THE APPROVAL OF THE ENGINEER BEFORE BEINGINSTALLED. DO NOT SCALE DRAWINGS.

L. PROVIDE AT LEAST 14 DAYS ADVANCE NOTICE TO THE COR FORANY UTILITY SHUT DOWNS.

M. LOCATE BALANCE VALVES SO THEY CAN BE ACCESSEDTHROUGH THE CEILING TILE OR PROVIDE ACCESS PANEL(S).

N. INSTALL EQUIPMENT WITH MINIMUM ACCESS CLEARANCE ASRECOMMENDED BY CODE AND MANUFACTURERS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

10/05/18RESPONSIBLE CHARGE

10/05/18COVERING HVAC DESIGN

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/5

/2018 5

:57:5

9 P

M

MP-106

6TH FLOOR PIPING NEW WORK

10/05/18 PP KG

1/8" = 1'-0"MP-106

1 6TH FLOOR PIPING - NEW WORK

1. PROVIDE NEW HOT WATER HEATING DISTRIBUTIONPIPING, VALVES, INSULATION, SPECIALTIES & HANGERS,ROUTED AS HIGH AS POSSIBLE. COORDINATE CLOSELYWITH DUCTWORK.

2. LOCATE RADIANT CEILING PANELS CLOSE TO EXTERIORSURFACES & CENTERED WITH REFERENCE TO WINDOWS,TO THE EXTENT POSSIBLE. COORDINATE CLOSELY WITHCEILING & LIGHTING LAYOUT.

3. WHERE A ZONE HAS MORE THAN ONE RADIANT PANEL,PANEL CONTROL VALVES SHALL OPERATE TO PARALLELFROM SINGLE SPACE CONTROL POINT.

4. PROVIDE 3-WAY CONTROL VALVE.

DRAWING NOTES:

GENERAL NOTES:

6TH FLOOR ROOM SCHEDULE

ROOM NO ROOM NAMEC6-23 CORRIDOR

C6-24 CORRIDOR

C6-25 CORRIDOR

C6001 LEARNERS

C6002 MD OFFICES

C6002A CHIEF

C6004 TLT RM

C6005 TLT RM

C6006 BREAK RM

C6007 CONF RM

C6008 PHYS

C6009 LEARNERS

C6010 NP

C6011 CHIEF

C6012 RN

C6013 LEARNERS

C6014 PHYS

C6015 MD OFFICE

C6016 MD OFFICES

C6017 MD OFFICE

C6018 MECH RM

C6019 MSA'S

C6020 VESTIBULE

C6021 BUS MNGR

C6022 CONFERENCE

C6023 PRACTICE MNGR

C6024 CHIEF

C6025 CHIEF

C6026 N CHIEF

C6027 N CHIEF

C6028 MSA SUPV

C6029 PSA

C6030 MD OFFICE

C6031 MECH. ROOM

C6032 MD OFFICE

1/4" = 1'-0"MP-106

2 ENLAGERED MECHANICAL ROOM

Revisions: Date:

2-1/2" HW

2-1/2" HW

NEW 3" HW/RRISERS

RADIANT CEILINGHEATING PANEL (TYP)

MP-107

2

3/4" HWS/R

RP-57

RP-58

RP-56

RP-55

RP-54

RP-53

RP-52

RP-51

RP-50

RP-81 RP-80 RP-79 RP-78 RP-77 RP-76

RP-75

RP-74

RP-73

RP-72RP-71RP-70RP-69RP-68

RP-46

RP-45

RP-44

RP-43

RP-42

RP-40

RP-47

RP-48

RP-49

RP-67

RP-66

RP-65

RP-64

RP-62

RP-61

RP-60

RP-59

VAV-32

VAV-33

VAV-38

VAV-40

VAV-41VAV-42

VAV-39

VAV-37

VAV-36

VAV-31

VAV-30

VAV-55

VAV-57

VAV-56

VAV-49 VAV-50VAV-51

CAV-54

VAV-52

VAV-53

VAV-44 VAV-45 VAV-46 VAV-47VAV-48VAV-43

VAV-58

VAV-60VAV-59

C7011 C7012

C7013

C7014 C7015

C7016

C7017

C7019 C7018C7021 C7020C7022

C7-11

C7031

C7032

C7033

C7034

C7035

C7036

C7037

C7037A

C7039

C7-9

S2-7

C7040

C7007

C7009

C-7178

C7-8

C7001A

C7001

C7003

C7003A

C7005

C7008

C7006

C-7077C-7079

C-7122

C-7123

C-7124

C-7138

C-7139

C7-25

C-7075

C-7059

C-7076

C7-7

S1-7

C7025

C7010

C-7081

48

C7026

C7027

C7028

C7029

C7030

C7023

C7024

C7-10

1 1/2" HWS/R

3/4" HWS/R

RADIANT CEILINGHEATING PANEL (TYP)

3/4'' HWS/R1 1/2'' HWS/R

3/4'' HWS/R

3/4'' HWS/R

3/4'' HWS/R

3/4'' HWS/R 3/4'' HWS/R 3/4'' HWS/R 3/4'' HWS/R

RADIANT CEILINGHEATING PANEL (TYP)

3/4'' HWS/R3/4'' HWS/R

1 1/2'' HWS/R

1 1/2'' HWS/R

1 1/2'' HWS/R

3/4'' HWS/R

2'' HWS/R

2' HWS/R

3/4'' HWS/R

3/4'' HWS/R

3/4'' HWS/R

3/4'' HWS/R

3/4'' HWS/R

3/4'' HWS/R

3/4'' HWS/R

3/4'' HWS/R

3/4'' HWS/R

1 1/2'' HWS/R

VAV-34

RP-63

RP-41

VAV-35

3

2

1

TYP.

TYP.

TYP.

6

6

6

T

T

T

T

T

T

T T T T T

T

TTT

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

MP-107

3

4

MP-107

3/4'' HWS/R

3/4'' HWS/R

3/4'' HWS/R

CAV-65

NEW 3" HW/RRISERS

RADIANT CEILINGHEATING PANEL (TYP)

1 1/2" HWS/R

RP-70 RP-72

RP-73

RP-75

RP-76RP-79

VAV-51 VAV-53

VAV-45

4

4

4

44

4

3/4" HWS/R

3/4" HWS/R

3/4" HWS/R3/4" HWS/R

2-1/2" HWS/R

2-1/2" HWS/R

C7040

4

MP-107

EXISTINGCHWS/R RISER

AHU-70

NEW 2-1/2" CHWS/R

Level 7a69'-5 1/4"

Level 7_781-5.2569' - 5 1/4"

Level 8_793-4.2581' - 4 1/4"

Level 7_781-5.2569' - 5 1/4"

Level 8_793-4.2581' - 4 1/4"

Level 7_781-5.2569' - 5 1/4"

2-1/2" HWS/R

NEW 4" HWS/RA. EXISTING WORK TO REMAIN AS INDICATED WITH LIGHT LINE

WEIGHT.

B. NEW WORK IS INDICATED WITH HEAVY LINE WEIGHT.

C. REMOVE ALL HANGERS, SUPPORTS, TUBING, AND CONTROLDEVICES ASSOCIATED WITH EQUIPMENT TO BE REMOVED.

D. COORDINATE ALL SYSTEM OUTAGES WITH OWNER.

E. ASBESTOS ON EXISTING PIPING, DUCT, AND EQUIPMENTSHALL BE REMOVED BACK TO MAIN BY ABATEMENTCONTRACTOR AND NEEDS TO BE RE-INSULATED BY THEMECHANICAL CONTRACTOR. WORK TO BE COORDINATEDWITH ABATEMENT CONTRACTOR.

F. LOCATE BALANCE DAMPERS SO THEY CAN BE ACCESSEDTHROUGH CEILING TILE OR WITH REMOTE BALANCE DAMPERADJUSTMENT DEVICE.

G. INSTALL ALL EQUIPMENT AND ACCESSORIES IN ACCORDANCEWITH MANUFACTURERS’ RECOMMENDATIONS, CONTRACTDOCUMENTS, AND APPLICABLE CODES AND REGULATIONS.

H. COORDINATE CONSTRUCTION OF ALL MECHANICAL WORKWITH OTHER DISCIPLINES: ARCHITECTURAL, PLUMBING,ELECTRICAL, ETC., SHOWN ON OTHER CONTRACTRDOCUMENTS.

I. ALL TESTS SHALL BE COMPLETED BEFORE ANY MECHANICALEQUIPMENT AND PIPING INSULATION IS APPLIED.

J. LOCATE ALL TEMPERATURE, PRESSURE, AND FLOWMEASURING DEVICES IN ACCESSIBLE LOCATIONS WITHSTRAIGHT SECTION OF PIPE OR DUCT UP AND DOWNSTREAMAS RECOMMENDED BY THE MANUFACTURER FOR GOODPERFORMANCE.

K. THE LOCATIONS OF ALL ITEMS SHOWN ON THE DRAWINGS ORREQUIRED BY THE SPECIFICATIONS NOT DEFINITELY FIXED BYDIMENSIONS ARE APPROXIMATE ONLY. THE EXACT LOCATIONSNECESSARY TO SECURE THE BEST RESULTS MUST BEDETERMINED BY THE PROJECT SITE CONDITIONS AND SHALLHAVE THE APPROVAL OF THE ENGINEER BEFORE BEINGINSTALLED. DO NOT SCALE DRAWINGS.

L. PROVIDE AT LEAST 14 DAYS ADVANCE NOTICE TO THE COR FORANY UTILITY SHUT DOWNS.

M. LOCATE BALANCE VALVES SO THEY CAN BE ACCESSEDTHROUGH THE CEILING TILE OR PROVIDE ACCESS PANEL(S).

N. INSTALL EQUIPMENT WITH MINIMUM ACCESS CLEARANCE ASRECOMMENDED BY CODE AND MANUFACTURERS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

10/05/18RESPONSIBLE CHARGE

10/05/18COVERING HVAC DESIGN

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/5

/2018 5

:58:0

4 P

M

MP-107

7TH FLOOR PIPING NEW WORK

10/05/18 PP KG

1/8" = 1'-0"MP-107

1 7TH FLOOR PIPING - NEW WORK 1/8" = 1'-0"MP-107

2 7TH FLOOR PIPING - NEW WORK - ALTERNATE

1. PROVIDE NEW HOT WATER HEATING DISTRIBUTIONPIPING, VALVES, INSULATION, SPECIALTIES & HANGERS,ROUTED AS HIGH AS POSSIBLE. COORDINATE CLOSELYWITH DUCTWORK.

2. LOCATE RADIANT CEILING PANELS CLOSE TO EXTERIORSURFACES & CENTERED WITH REFERENCE TO WINDOWS,TO THE EXTENT POSSIBLE. COORDINATE CLOSELY WITHCEILING & LIGHTING LAYOUT.

3. WHERE A ZONE HAS MORE THAN ONE RADIANT PANEL,PANEL CONTROL VALVES SHALL OPERATE TO PARALLELFROM SINGLE SPACE CONTROL POINT.

4. ALTERNATE BID: PROVIDE HOT WATER SUPPLY & RETURNPIPING, CONTROLS, VALVES, INSULATION, SPECIALTIESHANGERS & CONNECT TO AIR TERMINAL REHEAT COIL.PROVIDE VALVE & CAPPED EXTENSIONS FOR FUTURERADIANT PANEL.

5. ALTERNATE BID: PROVIDE HOT WATER SUPPLY & RETURNVALVED & CAPPED NEAR LOCATION OF AIR TERMINAL FORFUTURE AIR TERMINAL, REHEAT COIL & RADIANT PANEL.

6. PROVIDE 3-WAY CONTROL VALVE.

DRAWING NOTES:

GENERAL NOTES:

7TH FLOOR ROOM SCHEDULE

ROOM NO ROOM NAMEC7-8 CORRIDOR

C7-9 CORRIDOR

C7-10 CORRIDOR

C7-11 CORRIDOR

C7001 LOCKERS

C7001A STAFF TLT

C7003 LOCKERS

C7003A STAFF TLT

C7005 BREAK RM /MAIL RM

C7006 HSKP

C7007 WAITING ROOM

C7008 PAT TLT

C7009 RECEPT

C7010 CHECK OUT

C7011 EXAM

C7012 EXAM

C7013 TYPICAL TEAM RM

C7014 TLT RM

C7015 EXAM

C7016 EXAM

C7017 EXAM

C7018 TEAM RM

C7019 EXAM

C7020 EXAM

C7021 TEAM RM

C7022 EXAM

C7023 STOR

C7024 ELEC

C7025 SOILED HOLDING

C7026 TEAM RM

C7027 EXAM RM

C7028 TYPICAL EXAM RM

C7028 Room

C7029 EXAM RM

C7029 Room

C7030 TEAM RM

C7031 EXAM RM

C7032 EXAM RM

C7033 EXAM RM

C7034 STOR

C7035 EXAM/PROC ROOM

C7036 PAT TLT

C7037 EXAM/PROC

C7037A PAT TLT

C7039 CLEAN STORAGE

C7040 MECH RM

1/4" = 1'-0"MP-107

3 7TH FLOOR PIPING - NEW WORK MECH ROOM

1/4" = 1'-0"MP-107

4 ENLARGED MECHANICAL ROOM

Revisions: Date:

MP-401

5

MP-401

6

1

2

5

6

2

1

6

MP-401

3

MP-401

4

1

2

5

6

2

1

6

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

10/05/18RESPONSIBLE CHARGE

10/05/18COVERING HVAC DESIGN

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/5

/2018 5

:58:0

8 P

M

MP-401

HWS PIPING BASEMENT AND 1STFLOOR PLAN

10/05/18 PP KG

1/16" = 1'-0"MP-401

2 1ST FLOOR HWS PLAN

1/8" = 1'-0"MP-401

5 1ST FLOOR HWS ENLARGED PLAN EAST

1/8" = 1'-0"MP-401

6 1ST FLOOR HWS ENLARGED PLAN WEST

1. EXISTING HWS RISER

2. EXISTING HWR RISER

3. EXISTING ACOUSTICAL TILE CEILING - REMOVE ANDREPLACE AS REQUIRED FOR WORK ABOVE.

4. EXISTING GYPSUM BOARD CEILING - REMOVE ANDREPLACE AS REQUIRED FOR WORK ABOVE.

5. EXISTING GYPSUM BOARD CEILING - PROVIDE ACCESSPANEL FOR ACCESS AS REQUIRED FOR ACCESS TOVALVES ABOVE.

6. REPLACE EXISTING HWS VALVES WITH NEWCOMBINATION BALANCING VALVE-ISOLATION VALVE WITHMEMORY STEP. REPLACE EXISTING HWR VALVE WITHNEW ISOLATION VALVE.

DRAWING NOTES:

1/16" = 1'-0"MP-401

1 BASEMENT HWS PLAN

1/8" = 1'-0"MP-401

3 BASEMENT HWS ENLARGED PLAN EAST

1/8" = 1'-0"MP-401

4 BASEMENT HWS ENLARGED PLAN WEST

Revisions: Date:

MP-402

3

MP-402

4

MP-402

6

2

1

6

STAFF WORK ROOM

1

2

3

6

1

2

4

6

5

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

10/05/18RESPONSIBLE CHARGE

10/05/18COVERING HVAC DESIGN

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/5

/2018 5

:58:1

2 P

M

MP-402

HWS PIPING 2ND AND 3RD FLOOR

10/05/18 PP KG

1/16" = 1'-0"MP-402

1 2ND FLOOR HWS PLAN

1/16" = 1'-0"MP-402

2 3RD FLOOR HWS PLAN

1/8" = 1'-0"MP-402

3 2ND FLOOR HWS ENLARGED PLAN WEST

1/8" = 1'-0"MP-402

4 2ND FLOOR HWS PLAN ENLARGED PLAN EAST

1/8" = 1'-0"MP-402

6 3RD FLOOR HWS ENLARGED PLAN EAST

1. EXISTING HWS RISER

2. EXISTING HWR RISER

3. EXISTING ACOUSTICAL TILE CEILING - REMOVE AND REPLACEAS REQUIRED FOR WORK ABOVE.

4. EXISTING GYPSUM BOARD CEILING - REMOVE AND REPLACE ASREQUIRED FOR WORK ABOVE.

5. EXISTING GYPSUM BOARD CEILING - PROVIDE ACCESS PANELFOR ACCESS PANEL AS REQUIRED FOR ACCESS VALVESABOVE.

6. REPLACE EXISTING HWS VALVES WITH NEW COMBINATIONBALANCING VALVE-ISOLATION VALVE WITH MEMORY STEP.REPLACE EXISTING HWR VALVE WITH NEW ISOLATION VALVE.

DRAWING NOTES:

Revisions: Date:

MP-403

3MP-403

6

2

1

6

2

1

6

5

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

10/05/18RESPONSIBLE CHARGE

10/05/18COVERING HVAC DESIGN

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/5

/2018 5

:58:1

5 P

M

MP-403

HWS PIPNG 4TH AND 5TH FLOOR

10/05/18 PP KG

1/16" = 1'-0"MP-403

1 4TH FLOOR HWS PLAN

1/16" = 1'-0"MP-403

2 5TH FLOOR HWS PLAN

1/8" = 1'-0"MP-403

3 4TH FLOOR HWS PLAN ENLARGED PLAN WEST

1/8" = 1'-0"MP-403

6 5TH FLOOR HWS ENLARGED PLAN WEST

1. EXISTING HWS RISER

2. EXISTING HWR RISER

3. EXISTING ACOUSTICAL TILE CEILING - REMOVE AND REPLACEAS REQUIRED FOR WORK ABOVE.

4. EXISTING GYPSUM BOARD CEILING - REMOVE AND REPLACEAS REQUIRED FOR WORK ABOVE.

5. EXISTING GYPSUM BOARD CEILING - PROVIDE ACCESS PANELFOR ACCESS PANEL AS REQUIRED FOR ACCESS TO VALVESABOVE.

6. REPLACE EXISTING HWS VALVES WITH NEW COMBINATIONBALANCING VALVE-ISOLATION VALVE WITH MEMORY STEP.REPLACE EXISTING HWR VALVE WITH NEW ISOLATION VALVE.

DRAWING NOTES:

Revisions: Date:

MP-404

2

MP-404

3

11

10

9

3

4

3

21'-5 3/16"

CHASE 114

14

14

12

13

14

8

6

TYP.5

65

65

MP-404

5

MP-404

6

2

1

8

11

10

9

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

10/05/18RESPONSIBLE CHARGE

10/05/18COVERING HVAC DESIGN

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/5

/2018 5

:58:1

9 P

M

MP-404

HWS PIPING 8TH AND 9TH FLOOR

10/05/18 PP KG

1/16" = 1'-0"MP-404

1 9TH FLOOR HWS PLAN

1/8" = 1'-0"MP-404

2 9TH FLOOR HSW ENLARGED PLAN WEST

1/8" = 1'-0"MP-404

3 9TH FLOOR HWS ENLARGED PLAN EAST 1/16" = 1'-0"MP-404

4 8TH FLOOR HWS PLAN

1/8" = 1'-0"MP-404

5 8TH FLOOR HWS ENLARGED PLAN WEST

1. NEW HWS RISER

2. NEW HWR RISER

3. EXISTING ACOUSTICAL TILE CEILING - REMOVE ANDREPLACE AS REQUIRED FOR WORK ABOVE.

4. EXISTING GYPSUM BOARD CEILING AND EXISTING DIFFUSERSTO BE DEMOLISHED AND REPLACED WITH NEW ACOUSTICALTILE CEILING AND SQUARE DIFFUSERS.

5. PRIOR TO DEMOLITION, CONTRACTOR SHALL VERIFY ALLSOURCES TO AIR DEVICES AND PERFORM PRE-BALANCE.RECORD DATA PER EACH AIR DEVICE IN BALANCE REPORT.

6. 12 INCH BY 12 INCH GRILLES ARE ASSUMED TO BE OUTSIDEAIR SUPPLY AND/OR EXHAUST AND MAY BE REUSED IN NEWGRID TYPE CEILING WHERE POSSIBLE. NEW DIFFUSERSSHALL BE SQUARE HIGH PERFORMANCE CONE TYPE.CONTRACTOR SHALL SELECT DIFFUSER WITH NECK SIZECOMPATABLE WITH EXISTING DUCT. BALANCE NEWDIFFUSERS TO MATCH EXISTING AIR FLOWS DOCUMENTED INPRE-BALANCE REPORT.

7. EXISTING GYPSUM BOARD CEILING - PROVIDE ACCESSPANEL FOR ACCESS PANEL AS REQUIRED FOR ACCESS TOVALVES ABOVE.

8. PROVIDE NEW BRANCH PIPING FROM NEW HWS & HWRRISER TO EXISTING HWS/R DISTRIBUTION TO SERVE THISFLOOR, CONNECTION TO EXISTING WHOLE SHOWN.PROVIDE NEW COMBINATION BALANCING VALVE-ISOLATION VALVE WITH MEMORY STOP AT CONNECTIONPOINT FOR SUPPLY & NEW ISOLATION VALVE ATCONNECTION ON RETURN.

9. REPLACE EXISTING HWS VALVES WITH NEWCOMBINATION BALANCING VALVE-ISOLATION VALVE WITHMEMORY STOP. REPLACE EXISTING HWR VALVE WITH NEWISOLATION VALVE.

10. EXISTING HWS RISER

11 EXISTING HWR RISER

12. EXSITING HWR RISER TO 10TH FLOOR MECHANICALROOM

13. EXISTING PIPING TO WEST CHASE TO REMAIN

14. REMOVE AND REPLACE EXISTING 3" HWS & HWR PIPING IN9TH FLOOR CEILING. RISER WITH 4" PIPING AS SHOWNEXTENDED INTO CHASE 1.

DRAWING NOTES:

1/8" = 1'-0"MP-404

6 8TH FLOOR HWS ENLARGED PLAN EAST

Revisions: Date:

3" HWR

532

4

1

PUMPEDCONDENSATE

L. P. STEAM

4" HWS

4" HWS

4" HWR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

10/05/18RESPONSIBLE CHARGE

10/05/18COVERING HVAC DESIGN

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/5

/2018 5

:58:2

0 P

M

MP-405

HWS/HWR PIPING 10TH FLOORPENTHOUSE

10/05/18 PP KG

1/4" = 1'-0"MP-405

1 HWS PENTHOUSE PLAN

1. EXISTING HEATING HWS & HWR PIPING DOWN TOCORRIDOR ON 9TH FLOOR. CONTINUED ON SHEET MP-404.

2. EXISTING HEATING EQUIPMENT RACK.

3. EXISTING STEAM TO HOT WATER HEAT EXCHANGER.

4. REPLACE EXISTING AIR SEPARATOR WITH NEW SPIROTHERMOR EQUAL AIR/DIRT SEPARATOR WITH 3" CONNECTIONS.PROVIDE NEW 3" LINE WHERE SHOWN.

5. REPLACE EXISTING END SUCTION PUMPS. VALVES,STRAINERS, EXPANSION JOINTS ALSO TO BE REPLACED.REFER TO DETAILS & SCHEDULE. SHEET MH-601.

DRAWING NOTES:

Revisions: Date:

MP-406

4

C-6114

C-6129

C-6117

C-6142

84

C-6143

C-6140

C-6131

C-6132C-6133

C-6134

C-6139

C-6144

C-6128

C-6127

C-6141

MP-406

3

49

C-7176

C-7174

C-7173

C-7171

C-7177

C-7178

C-7139

C7-25

C-7138

C-7140

C7-8

C-7139

2

1

6

2

1

6

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

10/05/18RESPONSIBLE CHARGE

10/05/18COVERING HVAC DESIGN

C:\U

sers

\kyle

g\D

ocum

ents

\Revit L

ocal F

iles\India

napolis

_M

echanic

al_

kyle

.guggenheim

.rvt

10/5

/2018 5

:58:2

6 P

M

MP-406

HWS PIPING 6TH AND 7TH FLOOR

10/05/18 PP KG

1/16" = 1'-0"MP-406

1 6TH FLOOR HWS PLAN

1/16" = 1'-0"MP-406

2 7TH FLOOR HWS PLAN

1/8" = 1'-0"MP-406

3 7TH FLOOR HWS ENLARGED PLAN WEST

1/8" = 1'-0"MP-406

4 6TH FLOOR HWS ENLARGED PLAN WEST

1. EXISTING HWS RISER

2. EXISTING HWR RISER

3. EXISTING ACOUSTICAL TILE CEILING - REMOVE ANDREPLACE AS REQURIED FOR WORK ABOVE.

4. EXISTING GYPSUM BOARD CEILING - REMOVE ANDREPLACE REQUIRED FOR WORK ABOVE.

5. EXISTING GYPSUM BOARD CEILING - PROVIDE ACCESSPANEL FOR ACCESS PANEL AS REQUIRED FOR ACCESSTO PIPING ABOVE.

6. REPLACE EXISTING HWS VALVES WITH NEWCOMBINATION BALANCING VALVE-ISOLATION VALVE WITHMEMORY STEP. REPLACE EXISTING HWR VALVE WITHNEW ISOLATION VALVE.

DRAWING NOTES:

Revisions: Date:

DRYWALL CEILINGCROSS TEE, TYP.

HANGER WIRE AND MOUNTINGCHANNEL ATTACHED TO STRUCTUREREFER TO SPECIFICATION SECTION26 51 00

GYPSUMBOARD

DRYWALL CEILINGCROSS TEE, TYP.

CEILING MAINBEAM.

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTINGINSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.

WIRE TIE THROUGHMOUNTING CHANNEL& CROSS BEAM, TYP.

LOCKING SQUAREWASHER & NUT

JUNCTION BOX

6.35mm (1/4") SCREW

INTEGRAL GALVANIZED LIPPEDSTEEL MOUNTING CHANNEL

FIXTURE WHIP FROM JUNCTION BOX(1829mm (6') LONG MAX)

CEILING HANGER WIRE

GENERAL NOTE:

1. INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOUNTINGINSTRUCTIONS AND USING THE RECOMMENDED MOUNTING HARDWARE.

DRYWALL BORDER

LUMINAIRE.REFER TOSCHEDULE

CEILING CROSS BEAM

GYPSUM BOARD

CEILING CROSS BEAM

LUMINAIRE MANUFACTURER'SMOUNTING HARDWAREREFER TO SPECIFICATIONSECTION 26 51 00

LUMINAIRE.REFER TOSCHEDULE

GYPSUM BOARD (TYP)

CEILING MAIN BEAM

FIXTURE WHIP FROMJUNCTION BOX(1829mm (6') LONGMAX.)

3 TWIST MINIMUM(TYP)

LUMINAIRESUSPENSION WIRESREFER TOSPECIFICATIONSECTION 26 51 00

X

BASED ON MANUFACTURERS RECOMMENDATIONS

JUNCTION BOX ("F" INDICATES FLOOR MOUNTED)

600V 30A 3P, NON-FUSED DISCONNECT, UNLESS OTHERWISE NOTED.

FUSED DISCONNECT, SIZE FUSES FOR EQUIPMENT

SURFACE MOUNTED PANELBOARD OR AUTOMATIC TRANSFER

SWITCH AS INDICATED.

MOTOR.

J

POWER

a

LIGHTING

LVDRECESSED MOUNTED PANELBOARD

JUNCTION BOX WALL MOUNTED 48" AFF.J

A 1' x 4' FIXTURE. UPPERCASE LETTER INDICATES TYPEPER THE FIXTURE SCHEDULE. LOWERCASE LETTERINDICATES SWITCH. HATCH INDICATES FIXTURE IS ONEMERGENCY CIRCUIT

D

OCD

A

A

AA

2' x 4' FIXTURE. UPPERCASE LETTER INDICATESTYPE PER THE FIXTURE SCHEDULE. HATCHINDICATES FIXTURE IS ON EMERGENCY CIRCUIT

WALL MOUNTED LINEAR FIXTURE. UPPERCASELETTER INDICATESTYPE PER THE FIXTURE SCHEDULE. LOWERCASE LETTER INDICATESSWITCH.

A

WALL MOUNTED SCONCE. UPPERCASE LETTER INDICATES TYPE PERFIXTURE SCHEDULE. LOWERCASE LETTER INDICATES SWITCH.

EXIT SIGN WITH DIRECTIONAL ARROWS AS INDICATED

RECESSED FIXTURE, DOWNLIGHTUPPERCASE LETTER INDICATES TYPE PER FIXTURE SCHEDULE.LOWERCASE LETTER INDICATES SWITCH. "E" INDICATESBATTERY BACK-UP

A

WALL MOUNTED DIMMER SWITCH. PROVIDE 0-10V CONTROLWIRING, DAISYCHAINED TO EACH FIXTURE DRIVER TO DIM ALLLIGHTING WITHIN ROOM. EMERGENCY LIGHTING WITHIN ROOMSHALL MAINTAIN 100% LUMINOUS OUTPUT UPON LOSS OFPOWER. SET DIMMING CONTROLS TO PRESETS OF "100%","50%", "20%" AND "OFF".

WALL MOUNTED OCCUPANCY DIMMER SWITCH. PROVIDE 0-10VCONTROL WIRING, DAISYCHAINED TO EACH FIXTURE DRIVERTO DIM ALL LIGHTING WITHIN ROOM. EMERGENCY LIGHTINGWITHIN ROOM SHALL MAINTAIN 100% LUMINOUS OUTPUT UPONLOSS OF POWER.

WALL MOUNTED LOW VOLTAGE DIMMER SWITCH. PROVIDE0-10V CONTROL WIRING, DAISYCHAINED TO EACH FIXTUREDRIVER TO DIM ALL LIGHTING WITHIN ROOM. EMERGENCYLIGHTING WITHIN ROOM SHALL MAINTAIN 100% LUMINOUSOUTPUT UPON LOSS OF POWER.

WALL MOUNTED OCCUPANCY SENSOR

CEILING MOUNTED OCCUPANCY SENSOR. DUALTECHNOLOGY PIR/ULTRASONIC 360 DEGREE AT 10'.PROVIDE ADDITIONAL POWER-PACK AS REQUIRED. ALLLIGHTING WITHIN ROOM TO BE SWITCHED UPONOCCUPANCY EXCEPT EMERGENCY LIGHTING WHICH ISLEFT AT 100% OUTPUT, CONSTANTLY.

20 AMP, 125 VOLT TOGGLE SWITCH MOUNTED 42" AFF.a - CONTROLS LIGHTS WITH "a" DESIGNATION

OC COMBINATION MOTOR STARTER WITH MOTOR CIRCUIT PROTECTORSAND OVERLOADS SIZED FOR NAMEPLATE DATA

MANUAL MOTOR STARTER WITH OVERLOADS SIZED PERNAMEPLATE DATA

PUSHBUTTON

OC

NEMA 5-20R DUPLEX RECEPTACLE.DESIGNATIONS:WP = WEATHER PROOFGFI = 30mA GROUND FAULT PROTECTEDC = RECESSED CLOCK OUTLETE= FED FROM CRITICAL POWER SOURCE

NEMA 5-20R QUADRUPLEX RECEPTACLE.DESIGNATIONS:WP = WEATHER PROOFGFI = 30mA GROUND FAULT PROTECTEDC = RECESSED CLOCK OUTLETE= FED FROM CRITICAL POWER SOURCE

NEMA 5-20R QUADRUPLEX RECEPTACLE IN FLUSH FLOOR BOX

XAA

2' x 2' FIXTURE. UPPERCASE LETTER INDICATESTYPE PER THE FIXTURE SCHEDULE. LOWERCASELETTER INDICATES SWITCH. HATCH INDICATESFIXTURE IS ON EMERGENCY CIRCUIT

a a

a a

a a

a

a

a

DEVICE MOUNTING HEIGHTSSWITCHES 46" MOUNTING HEIGHT UNLESS OTHERWISE NOTED.

RECEPTACLES UNLESS OTHERWISE NOTED,18" MOUNTING HEIGHT46" OVER COUNTERS

TEL/DATA UNLESS OTHERWISE NOTED,18" MOUNTING HEIGHT46" OVER COUNTERS

X

NEMA 5-20R QUADRUPLEX RECEPTACLE, 46" MOUNTINGHEIGHT UNLESS NOTED OTHERWISE.DESIGNATIONS:WP = WEATHER PROOFGFI = 30mA GROUND FAULT PROTECTEDC = RECESSED CLOCK OUTLETE= FED FROM CRITICAL POWER SOURCE

XNEMA 5-20R DUPLEX RECEPTACLE. 46" MOUNTINGHEIGHT UNLESS NOTED OTHERWISE.DESIGNATIONS:WP = WEATHER PROOFGFI = 30mA GROUND FAULT PROTECTEDC = RECESSED CLOCK OUTLETE= FED FROM CRITICAL POWER SOURCE

EQUIPMENT CONNECTION

WIRINGEXPOSED

CONCEALED

GROUNDING

DOWN CONDUCTOR CONNECTION TO GROUND

ABBREVIATIONS

A AMPERE

AC ABOVE COUNTER, 42"AFF UNLESS OTHERWISE INDICATED

ADA AMERICANS WITH DISABILITIES ACT

AFF ABOVE FINISHED FLOOR

AL ALUMINUM

1/C ONE CONDUCTOR

C CONDUIT

CB CIRCUIT BREAKER

CKT CIRCUIT

CU COPPER

EF EXHAUST FAN

EMT ELECTRICAL METALLIC TUBING

EWC ELECTRIC WATER COOLER

FACP FIRE ALARM CONTROL PANEL

FM FREQUENCY MODULATION

GFI GROUND FAULT CIRCUIT INTERRUPTER

GFP GROUND FAULT PROTECTIONHACR HEATING AIR CONDITIONING REFRIGERATION

HP HORSEPOWER

HPS HIGH PRESSURE SODIUM

HT HEIGHT

HZ HERTZ

IDS INTRUSION DETECTION SYSTEM

J JUNCTION BOX

KWH KILOWATT HOUR

LED LIGHT EMITTING DIODE

MCB MOLDED CASE CIRCUIT BREAKER

MH METAL HALIDE

MLO MAIN LUGS ONLY

MTD MOUNTED

NEC NATIONAL ELECTRICAL CODE

NF NON FUSED

NO. NUMBER

OS OCCUPANCY SENSOR

PH PHASE

PIR PASSIVE INFRARED

RGS RIGID GALVANIZED STEEL

SM SINGLE MODE

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

SPD SURGE PROTECTIVE DEVICE

UNO UNLESS NOTED OTHERWISE

V VOLT

VA VOLTAMPERE

VVD VARIABLE VOLUME DAMPER

W WATTS

WP WATER PROOF

XFMR TRANSFORMER

FV FLUSH VALVE

FV FLUSH VALVE

H

LUMINAIRE(S)

LOW VOLTAGEON/OFF/DIMMINGWALL STATION

ADDITIONAL LV ON/OFFWALL STATION AS REQUIREDFOR MULTIPOINT CONTROL

LINE VOLTAGE

LV

PP

OCCUPANCYSENSOR

OCCUPANCYSENSOR

(AS REQUIRED)

LV

POWER PACK/RELAY

NETWORK BRIDGE

1

2

LV - LOW VOLTAGE CABLE. SEE MANUFACTURER FOR EXACT CABLE REQUIREMENTS.THIS DETAIL IS A GENERAL SCHEMATIC AND DOES NOT CONTAIN EXACT INFORMATION PER MANUFACTURER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:10:2

9 P

M

EI-001

ELECTRICAL GENERALINFORMATION

10/05/18 JB HT

LIGHTING FIXTURE SCHEDULETYPE DESCRIPTION VA LAMP(S) LUMINOUS FLUX COLOR TEMP.

A1

LED EXIT SIGN, EDGE-LIT DESIGN, CEILING OR WALL MOUNTED WITH RED LETTERS, UNIVERSALVOLTAGE (120-277V).

STATIC RECESSED 2 X 2 DIRECT/INDIRECT TYPE LED FIXTURE WITH CENTER MOUNTEDCONCEALED ILLUMINATION PERFORATED BASKET. HOUSING SHALL BE PAINTED WITH WHITEPOLYESTER POWDER OR BAKED ENAMEL. UNIVERSAL VOLTAGE (120-277V).

B1 4' SUSPENDED DIRECT/INDIRECT TYPE LED FIXTURE WITH PERFORATED BASKET. HOUSINGSHALL BE PAINTED WITH WHITE POLYESTER POWDER OR BAKED ENAMEL. UNIVERSALVOLTAGE (120-277V).

2' LED WRAP. PAINTED WITH WHITE POLYESTER POWDER OR BAKED ENAMEL. WALLMOUNTED ABOVE DOOR. UNIVERSAL VOLTAGE (120-277V).

F1

D1 6" LED DOWNLIGHT. UNIVERSAL VOLTAGE (120-277V).

X1 2.7 LED - -

CRI DIMMINGIMAGE

A2

LED 3500K

22 LED 2200 lm 3500K 90 CRI

18 LED 2070 lm 3500K >80 CRI

90 CRI23 LED 1786 lm 3500 K

32 3200 lm 90 CRI

-

0-10V

0-10V

0-10V

0-10V

D2 2'' LED WALLWASH, 45 DEGREE CUTOFF. 120V 90 CRI22.3 LED 1200 lm 3500 K 0-10V

STATIC RECESSED 2 X 4 DIRECT/INDIRECT TYPE LED FIXTURE WITH CENTER MOUNTEDCONCEALED ILLUMINATION PERFORATED BASKET. HOUSING SHALL BE PAINTED WITH WHITEPOLYESTER POWDER OR BAKED ENAMEL. UNIVERSAL VOLTAGE (120-277V).

5000 lmLED50A2 3500K 90 CRI 0-10V

X2 LED EXIT SIGN, EDGE-LIT DESIGN, CEILING OR WALL MOUNTED WITH RED LETTERS, CHEVRONDIRECTIONAL ARROWS, UNIVERSAL VOLTAGE (120-277V).

LED - - -2.7

E1 LED2'x4' LED FIXTURE FROM SALVAGE. REFER TO ED SERIES DRAWINGS FOR ADDITIONALINFORMATION.

2200 lm 3500 K 90 CRI STEPDIMMING

17.8

S1 2' LED STRIPLIGHT, FROSTED REFRACTOR, WHITE HOUSING. 3500 K COLOR TEMPERATURE.120-277V.

10 LED 800 lm 3500K 85 CRI 0-10V

W1 ARCHITECTURAL SCONCE. DARK WALNUT FINISH. LOW VOLTAGE, 12V WITH TRANSFORMER 12.5 LED 860 lm 2700 K 90 CRI LOWVOLTAGE

3

EI-001

SINGLE ROOM LIGHTING CONTROLSN.T.S.

1

EI-001

EXIT SIGN - CEILING MOUNTEDN.T.S.

2

EI-001

LUMINAIRE DETAIL - CEILING MOUNTEDN.T.S.

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

T

J

C6LE2

3

C6LE34

C6AC1

C6162

C6001

C6002

C6041

C6-24

C6003

C6006 C6007 C6008 C6009 C6010

C6011C6012C6013C6014C6015

C6018

C6020

C6021

C6023

C6024

C6025

C6027

C6028

C6030

C6032

C6033

C6034

C6016

C6005

C6LE1-5

C6LE1-19

C6LE1-21

C6LE1-3

C6LE1-25C6LE1-27C6LE1-38C6LE1-40C6LE1-42

C6LE1-23C6LE1-32C6LE1-34C6LE1-36

C6LE1-11

7

C6LE1-26

C6LE2-1

C6004C6LE2-5

C6LE2-9

C6LE2-19C6LE2-25

C6LE2-33

C6019C6LE2-2

C6017C6LE2-4

C6LE2-41

C6LE2-12

C6LE2-14

C6LE2-16C6LE2-18

C6LE2-26

C6LE2-30

C6LE2-28

C6LE2-40

C6LE2-42

C6LN1-20C6LN1-22C6LN1-24

C6LN1-15

?

C6LE2-8

C6LE2-20

C6LE2-10

C6LE2-24

C6016

C6LE2-6

C6LN1-18

C6HEX

C6LN1

C6LE1

56

6

6

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:10:2

0 P

M

ED-106

PARTIAL SIXTH FLOORDEMOLITION PLAN

10/05/18 JB HT

1/8" = 1'-0"ED-106

1 PARTIAL SIXTH FLOOR DEMOLITION PLAN

1. NOTE NOT USED.2. NOTE NOT USED.3. DISCONNECT AND REMOVE SWITCHES AND ASSOCIATED WIRING BACK TO

SOURCE OR NEAREST ACTIVE DEVICE. TYPICAL FOR ALL DEVICES WITHINAREA OF GENERAL DEMOLITION.

4. DISCONNECT AND REMOVE EXISTING ABANDONED PANELBOARD. REMOVEALL ASSOCIATED CONDUIT AND WIRE.

5. DISCONNECT AND REMOVE EXISTING PANELBOARD BACK TO SOURCE.REMOVE CONDUIT AND WIRE BACK TO SOURCE AND DOWNSTREAM OFPANEL.

6. DISCONNECT AND REMOVE PANEL. EXISTING TO BE REPLACED. REFER TOPOWER PLANS AND PANELBOARD SCHEDULES.

7. DISCONNECT 120V POWER TO TECHNOLOGY PANELS BACK TO SOURCE.REFER TO TECHNOLOGY DRAWINGS FOR PANEL LOCATIONS.

DRAWING NOTES:

A. UNLESS NOTED OTHERWISE, DISCONNECT AND REMOVE EXISTINGELECTRICAL DEVICES, LIGHTING FIXTURES AND ALL ASSOCIATED CONDUITAND CABLING IN AREAS SHOWN TO BE DEMOLISHED. REMOVE CONDUIT ANDWIRE BACK TO SOURCE OR LAST ACTIVE DEVICE. MAINTAIN CONDUIT ANDWIRE TO ELECTRICAL DEVICES AND LIGHTING FIXTURES WHICH ARE TOREMAIN. REWORK CONDUIT AND WIRE AS REQUIRED TO MAINTAINOPERATION OF DEVICES TO REMAIN.

B. ALL DEMOLISHED MATERIAL SHALL BE REMOVED FROM SITE UNLESSNOTED TO BE RE-USED OR TO BE SALVAGED AND TURNED OVER TOOWNER.

C. IF CIRCUITING IS NOT RE-USED, REMOVE CONDUIT & WIRING BACK TOPANELBOARD & MARK CIRCUIT BREAKER AS 'SPARE'.

GENERAL NOTES:

0

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

3

C7AC1

C7005

C7009

C7010

C7016C7015C7013C7-9

C7018C7022

C7044

C7045

C7039

C7033

C7053

C7034

C7056

C7-11

C7011

C7020

C7019C7023

C7031

C7035

C7054C7015

C7027

C7LE1-14

C7LE1-3

C7LE1-37

C7LE2-2C7LE1-31

C7LE2-4C7LE1-25 C7LE1-41

C7LE1-39

C7LE1-30 C7LE1-28C7LE2-6

C7LE2-14C7LE2-12

C7LE2-23C7LE1-33

C7LE2-1

C7LE2-5C7LE2-15

C7LE2-3

C7LE2-11

C7LE2-17

C7LE2-19C7LE2-9C7LE1-6

C7LE2-25C7LE2-16C7LE2-18

C7LE2-13

C7LE1-20

C7LE2-7

C7LE1-19

C7179

C7002

C7001

C7003

C7004C7058

C7057

C7055

C7051

C7049

C7048

C7047

C7046

C7043

C7042

C7041

C7040

C7038

C7037

C7036

C7032

C7030

C7029

C7026 C7025 C7021

C7014C7012C7008

C7007

C7006

C7028 C7024

C7050

C7LE1-23

4

4

4

5

C7LE4

C7LN1

C7LE1

C7LE24

6J

C7LN1-12

C7LN1-10

C7LN1-28C7LN1-30

C7LN1-40C7LN1-38C7LN1-36

C7LN1-37C7LN1-22C7LN1-20

C7LN1-39

C7LN1-7

C7LN1-24

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:10:2

5 P

M

ED-107

PARTIAL SEVENTH FLOORDEMOLITION PLAN

10/05/18 JB HT

1/8" = 1'-0"ED-107

1 PARTIAL SEVENTH FLOOR DEMOLITION PLAN

1. NOTE NOT USED.2. NOTE NOT USED.3. DISCONNECT AND REMOVE SWITCHES AND ASSOCIATED WIRING BACK TO SOURCE OR

NEAREST ACTIVE DEVICE. TYPICAL FOR ALL DEVICES WITHIN AREAS OF GENERALDEMOLITION.

4. DISCONNECT AND REMOVE PANEL. EXISTING TO BE REPLACED. REFER TO POWER PLANSAND PANELBOARD SCHEDULES.

5. DISCONNECT AND REMOVE POWER TO PUMPS AND ELECTRIC WATER HEATER BACK TOC7LE4. WATER HEATER AND PUMPS TO BE RELOCATED.

6. WORK WITHIN PANEL PROHIBITED. ANY CIRCUITS HOMERUN TO EXISTING PANEL MADESPARE TO BE TERMINATED IN JUNCTION BOX ABOVE CORRIDOR CEILING. PROVIDEPHENOLIC TAG TO READ "C7AC1 SPARE CIRCUITS ABOVE".

DRAWING NOTES:

A. UNLESS NOTED OTHERWISE, DISCONNECT AND REMOVE EXISTING ELECTRICAL DEVICES,LIGHTING FIXTURES AND ALL ASSOCIATED CONDUIT AND CABLING IN AREAS SHOWN TO BEDEMOLISHED. REMOVE CONDUIT AND WIRE BACK TO SOURCE OR LAST ACTIVE DEVICE.MAINTAIN CONDUIT AND WIRE TO ELECTRICAL DEVICES AND LIGHTING FIXTURES WHICHARE TO REMAIN. REWORK CONDUIT AND WIRE AS REQUIRED TO MAINTAIN OPERATIONOF DEVICES TO REMAIN.

B. ALL DEMOLISHED MATERIAL SHALL BE REMOVED FROM SITE UNLESS NOTED TO BE RE-USED OR TO BE SALVAGED AND TURNED OVER TO OWNER.

C. IF CIRCUITING IS NOT RE-USED, REMOVE CONDUIT & WIRING BACK TO PANELBOARD &MARK CIRCUIT BREAKER AS 'SPARE'.

GENERAL NOTES:

0

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

1

C-9036

C-9032

C-9030

C9-4

C9-5

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:10:2

7 P

M

ED-109

PARTIAL NINTH FLOORDEMOLITION PLAN

10/05/18 JB HT

1/8" = 1'-0"ED-109

1 PARTIAL NINTH FLOOR DEMOLITION PLAN

DRAWING NOTES:1. REMOVE EXISTING LIGHTING FIXTURES AND SALVAGE

FOR RECONNECTION. MAKE SAFE WIRING TOFIXTURES FOR CONNECTION TO RELOCATED LIGHTFIXTURES. REFER TO EL-109 FOR NEW LAYOUT.

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

OC

OC

OC

OC

OC OC

OC

OC

OC OC

OC

OC

OC

OC

OC

C6031

C6-24

C6001

C6002

C6002A

C6006

C6004

C6005

C6007 C6008

C6010

C6011

C6012

C6013C6014C6015

C6017

C6019

C6021

C6023

C6024

C6028

C6029

C6030

C6032

C6009

C6027

C6022

C6026

C6025

C6016

C6-23

C6020

S2-6

S1-6

C6LE2

OCOC

OCOC

OCOC

OC OC

OC

OC

OC

OC

OC

OCOC

CORRIDOR DUALSWITCHING

A2

A2

A2A2

A2A2

A1 A1

A2

A2

A2A2

A2A2

A2

A2

A2

A2A2

A2 A2

A2

A2

A2

A2

A2

E1E1

A2

E1

A2 A2

A2 A2

A2

A2

A2A2

A2 A2

A2

A2

E1 E1E1 E1

C6LN1

X1

X2

X1

X1

C6HEX

C6LLS1

C6LE1

C6LN3

d

d d

d d

1313

13

11 11 11

1111

1111

11

11

11

1 1111 1

11 11 1

11

9

9

99

9 9

9 99

9

99

99

9 9 9 9

9

13

13

13

13

13

1

1

1

1

13

13

11

1

9

9

1

9

9

1

9

9

E1

E1

E1

E1

E1

E1

E1

E1

E1

E1

E1

E1

F113

F1

11

1

C6007

1

E1

A2

A211

A2

A2A2

A2A2

A2A2

A2A2

A2

11

11

11

11

11

11

11

11

11

11

A21

A213

A2 A2

A2

A2

A2

A2

A2

A2

A2

A21111

11 11

9

99

11

13

13

9

OC

A2A2

A2 A2

A2

13 13

113

13

A211

A2 A2A2

A2

A2

A2A2

A2 A2

A2

A2

9

99 9

9

9 9

99

11

11

A2

A2

9

9

1A2

a a a

aaa

a

bb

b b

bbb

c c

c

OC

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:10:3

4 P

M

EL-106

PARTIAL SIXTH FLOOR LIGHTINGPLAN

10/05/18 JB HT

1/8" = 1'-0"EL-106

1 PARTIAL SIXTH FLOOR LIGHTING PLAN

CIRCUITING LEGEND:

CIRCUIT ALL LIGHTING TO THE FOLLOWING PANELS:NORMAL: C6LN1EMERGENCY: C6LE1

NOTE:

1. EMERGENCY FIXTURES ARE DESIGNATED WITH HATCH.2. CIRCUIT FIXTURES TO CIRCUIT NUMBER LISTED IN PLAN WITH

PANEL ABOVE.

DRAWING NOTES:0

1. PROVIDE (3)#12, #12G, 3/4"C. REFER TO 4/EL-107 FOR DIAGRAM.

ROOM SCHEDULE - 6TH FLOOR

Number Name

C6-23 CORRIDOR

C6-24 CORRIDOR

C6-25 CORRIDOR

C6-30 CORRIDOR

C6-31 CORRIDOR

C6-32 LOBBY

C6-33 CORRIDOR

C6001 LEARNERS

C6002 MD OFFICES

C6002A CHIEF

C6004 TLT RM

C6005 TLT RM

C6006 BREAK RM

C6007 CONF RM

C6008 PHYS

C6009 LEARNERS

C6010 NP

C6011 CHIEF

C6012 RN

C6013 LEARNERS

C6014 PHYS

C6015 MD OFFICE

C6016 MD OFFICES

C6017 MD OFFICE

C6018 MECH RM

C6019 MSA'S

C6020 VESTIBULE

C6021 BUS MNGR

C6022 CONFERENCE

C6023 PRACTICE MNGR

C6024 CHIEF

C6025 CHIEF

C6026 N CHIEF

C6027 N CHIEF

C6028 MSA SUPV

C6029 PSA

C6030 MD OFFICE

C6031 MECH. ROOM

C6032 MD OFFICE

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

OC

OC

OC

OC

OC

OC

OC

OC

OC OC

OC

OC

OC

OC

OC

OCD

D

D

D

D

D

DD

D

D

D

OC

E1

A1

A1

A1

A1

A1 A1

A1

A1

E1

E1

A2 A2

A2

A2

A2

A2

A2

A2

A2 A2

A2

A2

A2

A2

A2

A2A2

A2A2

A2

E1

E1

E1

A2

A2

D1

D1

D1

D1

D1

D1

A1

A1

A1

D1

D1

D1

D1

A2

A2

A2

A2

A2

A2

A2

A2

A2

D1

D1

D1 D1

1

X1

X1

EL-1073

C7LE4

C7LE2

C7LN1

C7LE1

C7AC1

C7LL1

C7HEX

C7034

C-7178

C7-8

C-7077

C-7138

C-7139

C7-25

C-7076

C7-7

S1-7

C7010

48

C7001

C7001A

C7003A

C7003

C7005

C7006

C7008

C7-11

C7009

C7011 C7012C7013

C7014 C7015 C7016

C7017C7018C7019C7020C7021C7022

C7023

C7025

C7024

C7-9

C7040

C7026

C7027

C7028

C7029

C7030

C7031

C7032C7033

C7035

C7036

C7037A

C7037

C7039

S2-7

C7007

C-7059

C-7075

C7-10

A2

A2 A2

A2

A2

A2

A1

E1 E1 E1 E1

A2 A2

A2A2

A2

A2

DOCD D D D D

DD

OC

OCDDD

34

34

3434

34

34

34

2

34 34

34

2

34

34

2

34

2

2

34

34

3434

34

34

34

40

40 40

40

40

40

2

40

40

40

40

40402402

40

40

40

40

34

11 11

11

11 11

1111

1111

11

11

11 11

2

11111111

1111

34 34

342

2

34

3434

11 11

c d

c

c

c

c

d

d

d

d

c

a

a

a

a

a

a

a

a

b

b

b

a

c

c

d

E1

F134

11

F134

OC

E111

E12

34 2

34

342

34

34

34

F1 F1

F1

F1

F1

F1

F1

F1

2

C7LE1

E111

E1

E1

E1

E1

A2 A2

A2A2

11 11

1111

11

2

11

2

40A2

40 40 40

40

40

40

A2 A2 A2

A2A2

A2

34

34

34

34

34

D1

D1

D1

D1

D1

D2

D2

34

34

D134

2F1

34

D2

D2

D2

34

34

b

D234

D234

S1

S1

S1

S1

S1

S1

S1

S1S1S1S1

11 11

11

11

11

S111

40

40 40S1S1

40

40404040

2 2

A2

A2

A2

40

40 40

2

34

2

E1

E1

E1

A2 A2

D1

D1

D1

D1

11

11

11

11

2X1

X12

X12

X12

2

E140

E12

11 11

34

S111

S111

34E1

W1 W134 34

34

34

W1

W1

D

D

D

c

d

a

d c

dc

3

zz

zzy

yy

y

y

x

x

x

zy

y y

y y

z

y yy

zz

y y

z

y

x

x

z

z

y

y y

z

y

zz

y y

z

yz

y y

z

y

y

y

z

y

y

y

z

y

z

y

y

z

y

y

y

z

z

z

z

y

y

y

z

z

y

y

yy

y

y

z

z

z

z

y

y

y

y

x

x

z

EL-1072

ALT. E-1

ALTERNATE-1

ALTERNATE-1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

B1

34 34 34 43 34 34 34

43 34 34 34 34 34 43

34 34 34 43 34 34 34

8686

NURSES STATION

SCONCESa

bCORRIDORDUALSWITCHING

2c

d

LINE

L1

L2

L1

L2

L1

L2

N

G

G

N

E1 E2

CONT.

N

G

c

d

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:10:4

3 P

M

EL-107

PARTIAL SEVENTH FLOORLIGHTING PLAN

10/05/18 JB HT

1/8" = 1'-0"EL-107

1 PARTIAL SEVENTH FLOOR LIGHTING PLAN 1/8" = 1'-0"EL-107

2 PARTIAL FLOOR LIGHTING PLAN ALTERNATE-1

1/2" = 1'-0"EL-107

3 DETAIL

1. FIELD ADJUST OPTICS TO ACCENT FEATURE WALLS AND CORRIDOR SPACE.COORDINATE WITH ARCHITECTURAL FINISHES. ARROW INDICATES ROUGHDIRECTIONALITY.

2. PROVIDE (3)#12, #12G, 3/4"C DAISY-CHAINED TO EACH CORRIDOR FIXTURE INPARALLEL. REFER TO 4/EL-107 FOR DIAGRAM.

3. NON-EMERGENCY FIXTURES ENCLOSED WITHIN THIS REGION ARE CIRCUITEDTO PANEL C7AC1.

DRAWING NOTES:0

CIRCUITING LEGEND:CIRCUIT ALL RECEPTACLES TO THE FOLLOWING PANELS:NORMAL: C7LN1, C7AC1EMERGENCY: C7LE1

NOTE:1. EMERGENCY FIXTURES ARE DESIGNATED WITH HATCH.2. CIRCUIT FIXTURES TO CIRCUIT NUMBER LISTED IN PLAN WITH PANEL ABOVE.

3/4" = 1'-0"EL-107

4 DUAL SWITCH WIRING DIAGRAM

ROOM SCHEDULE - 7TH FLOOR

Number Name

C7-6 CORRIDOR

C7-7 CORRIDOR

C7-8 CORRIDOR

C7-9 CORRIDOR

C7-10

C7-10A SHELL SPACE

C7-11 CORRIDOR

C7-25 FREIGHT ELEVATORS LOBBY

C7001 LOCKERS

C7002 STAFF TLT

C7003 LOCKERS

C7004 STAFF TLT

C7005 BREAK RM /MAIL RM

C7006 HSKP

C7007 WAITING ROOM

C7008 PAT TLT

C7009 RECEPT

C7010 CHECK OUT

C7011

C7012 EXAM

C7013 TYPICAL TEAM RM

C7014 TLT RM

C7015

C7016 EXAM

C7017 EXAM

C7018

C7019 EXAM

C7020 EXAM

C7021

C7022

C7023

C7024

C7025

C7026

C7027 EXAM RM

C7028

C7029

C7030 TEAM RM

C7031

C7032 EXAM RM

C7033 EXAM RM

C7034 STOR

C7035 EXAM/PROC ROOM

C7036 PAT TLT

C7037 EXAM/PROC

C7038 PAT TLT

C7039

C7040 MECH RM

CORRIDOR

EXAM

EXAM

TEAM RM

TEAM RM

EXAM

STOR

ELEC

SOILED HOLDING

TEAM RM

TYPICAL EXAM RM

EXAM RM

EXAM RM

CLEAN STORAGE

EXAM

EXAM

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

A2 A2

A2A2

A2 A2

A2A2

E1E1

E1

E1

E1

1

C-9036

C-9032

C-9030

C9-4

C9-5

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:10:4

6 P

M

EL-109

PARTIAL NINTH FLOOR LIGHTINGPLAN

10/05/18 JB HT

1/8" = 1'-0"EL-109

1 PARTIAL NINTH FLOOR LIGHTING PLAN

DRAWING NOTES:

1. EXTEND/RECONNECT POWER TO RELOCATED LIGHTING FIXTURE.TYPICAL FOR THIS FIXTURE TYPE.

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

J

1

GFI GFI

GFIGFI

GFI

2

2

2

3

C6LE24

WIREWAY,FLUSHWITH TILE

1

5

1

C6LN1

C6LE1

C6AC1

C6LLS1

BUS DUCT

C6HEX

BP-1

BP-2

EWH-1

C7LE4-25,27,29

4

4

C6LN3

1 1 1

9

2

4

2

4

9 3

3

9

5

5

9

5

9

6

66

7

8

10

10

10

910

10

11

11 11

13

1212

12

11

1313

15 15

15

14

11

17

17

17

11

11

14

18

1818

19

19

2011

11

19

20

21

21

21

22

43

22

19

22

23

19

2324

2424

27

2519

25

272719

26

28

26

28 28

3030

29

30

31

31

1932 32

32

3333

33

33

3434

33

34

33

36

3333

36

33

37

37

41

41

38

41

3839

39 39

40 40

4041

4141

41

26

19

41 6

42

42

42

35

VAV-1

VAV-2

VAV-3

VAV-4

VAV-5

VAV-6

VAV-7

VAV-8

VAV-9

VAV-11

VAV-10

VAV-12

VAV-13

VAV-14VAV-15VAV-17 VAV-16

VAV-18

VAV-19

VAV-20

CAV-21VAV-22

VAV-23

VAV-24

VAV-25

VAV-26

VAV-27

VAV-28

VAV-29

43

22

9

EE

EE

E

E

E

E E

EE

E

E

E

E

EE

E

E

E

E

E

E

E

E

E

E

E

E

6

C6LE1-3

2

3

11

24

35

RECEPTACLEFOR RCP-1

C7LE4-3

7

VAV-62

CAV-61

VAV-64

GFI

16

16

16

16

16

16

16

1616

16

15

15

15

15 1515 15

15

15

15

1818

18

18

18

18

18

18

18

1818

GFI

POWER TO FD-3C6LE2-2

C6LE2-4

POWER TOFD-1

POWERTO FD-2C6LE2-4

C6LE2-2POWER TO FD-4

POWER TO FD-6

POWER TO FD-7

POWER TO FD-8C6LE2-6

C6LE2-8

C6LE2-10

C7LE4-16,18,20

C7LE4-19,21,23

10 10FV FV10 10

SV

SV

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:10:5

1 P

M

EP-106

PARTIAL SIXTH FLOOR POWERPLAN

10/05/18 JB HT

1/8" = 1'-0"EP-106

1 PARTIAL SIXTH FLOOR POWER PLAN

1. TV WALL BOX, CONCEALED BEHIND TELEVISION. COORDINATE FINAL INSTALLEDELEVATION WITH TELEVISION PLACEMENT. RECESS RECEPTACLE WITHIN TV WALLBOX.PROVIDE POWERFROM DUAL DUPLEX TO JUNCTION BOX ABOVE CEILING.

2. POWER DATA AND FLOORBOX INSTALLED FROM CEILING BELOW. PROVIDEQUADRAPLEX.

3. PROVIDE 3.7" IN-CARPET STYLE WIREWAY. SYSTEM SHALL NOT DISTURB SLAB ANDSHALL BE INSTALLED FLUSH WITH SURFACE OF TILE. PROVIDE FULL SYSTEMCOMPLETE WITH REMOVABLE TRACK, MODULAR QUAD RECEPTACLE; COORDINATEMODULAR DEVICES WITH AV REQUIREMENTS. PROVIDE RAMPS, TRACK, WALL TRIM,AND ALL NECESSARY APPURTENANCES. REFER TO DETAILS FOR ADDITIONALINFORMATION.

4. PROVIDE NEW PANEL TO REPLACE EXISTING, PER SINGLE LINE AND PANELSCHEDULES. RECONNECT FEEDERS AND CIRCUITRY REMAINING FROM DEMOLITION.

5. PROVIDE #4 GROUND CABLE FROM EXISTING SIGNAL CLOSET TO NEW CABLE TRAY.REFER TO 'T' DRAWINGS FOR CABLE TRAY.

6. PROVIDE EMERGENCY POWER TO SMOKE DAMPER PER MANUFACTURERSINSTRUCTIONS. DAMPER TO CLOSE UPON SMOKE DETECTION.

DRAWING NOTES:

A. POWER PANEL DOOR SCHEDULES MUST BE UPDATED TO REFLECT THE CHANGES TOTHE ROOM NAMES AND NUMBERS AS A RESULT OF THIS SCOPE OF WORK.

B. CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO ANY FABRICATION ORCONSTRUCTION.

C. CONTRACTOR TO NOTIFY OWNER REPRESENTATIVE OF ANY DISCREPANCIES ANDOBTAIN OWNER APPROVAL FOR ANY CHANGES.

D. ELECTRICAL DEVICE LOCATIONS ARE APPROXIMATE. COORDINATE WITH EQUIPMENT INAREA AND OWNER FOR FINAL DEVICE LOCATIONS.

E. CONDUIT TO BE FIELD ROUTED. PROVIDE PULL BOXES AS REQUIRED PER NEC ORCONSTRUCTION CONDITIONS.

F. CONTRACTOR TO SIZE CONDUIT AND CONDUCTORS BASED UPON MAXIMUMALLOWABLE LOAD FOR CIRCUIT BREAKER SIZE SHOWN AND DE-RATING FACTORSREQUIRED FOR FILL AND VOLTAGE DROP.

G. PROVIDE SEPARATE INSULATED EQUIPMENT GROUNDING CONDUCTOR WITHIN EACHFEEDER AND BRANCH CIRCUIT RACEWAY. TERMINATE EACH END ON SUITABLE LUG,BUS OR BUSHING.

H. CONTRACTOR TO PROVIDE ALL NECESSARY SUPPORTS TO FACILITATE INSTALLATIONOF THEIR DISCIPLINE EQUIPMENT, INDEPENDENT OF OTHER DISCIPLINES.

I. PROVIDE TAMPER-RESISTANT RECEPTACLES IN BUSINESS OFFICES, CORRIDORS,WAITING ROOMS AND THE LIKE IN CLINICS, MEDICAL AND DENTAL OFFICES ANDOUTPATIENT FACILITIES.

GENERAL NOTES:

0

CIRCUITING LEGEND:

CIRCUIT RECEPTACLES TO THE FOLLOWING PANELS:NORMAL: C6LN3EMERGENCY: C6LE2

NOTE:

1. EMERGENCY RECEPTACLES ARE DESIGNATED BY THE LETTER 'E'.2. CIRCUIT FIXTURES TO CIRCUIT NUMBER LISTED IN PLAN WITHIN PANEL ABOVE.3. PROVIDE POWER TO VAVs FROM PANEL C6LN1 AND CIRCUIT INDICATED.

ROOM SCHEDULE - 6TH FLOOR

Number Name

C6-23 CORRIDOR

C6-24 CORRIDOR

C6-25 CORRIDOR

C6-30 CORRIDOR

C6-31 CORRIDOR

C6-32 LOBBY

C6-33 CORRIDOR

C6001 LEARNERS

C6002 MD OFFICES

C6002A CHIEF

C6004 TLT RM

C6005 TLT RM

C6006 BREAK RM

C6007 CONF RM

C6008 PHYS

C6009 LEARNERS

C6010 NP

C6011 CHIEF

C6012 RN

C6013 LEARNERS

C6014 PHYS

C6015 MD OFFICE

C6016 MD OFFICES

C6017 MD OFFICE

C6018 MECH RM

C6019 MSA'S

C6020 VESTIBULE

C6021 BUS MNGR

C6022 CONFERENCE

C6023 PRACTICE MNGR

C6024 CHIEF

C6025 CHIEF

C6026 N CHIEF

C6027 N CHIEF

C6028 MSA SUPV

C6029 PSA

C6030 MD OFFICE

C6031 MECH. ROOM

C6032 MD OFFICE

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

J

E

E

E

E

E E

E

E

GFIE

E

E

GFIGFI

E

E

EE

E

GFIE

E

E

E E

E E

E

E

GFI

GFIGFIGFI

GFI

GFI

8POWER TO 600lb PATIENT LIFT

3

C7AC1

C7LN1

C7LE1

4

5 4

6

AHU-70

EP-1072

C7LE4

C7032C7033

C7035

C7031

C7030

C7036

C7037A

C7029

C7037

C7028

C7027

C7039

C7026S2-7

C7025

C7022

C7020C7021

C7018C7019

C7017

C7-11

C7016

C7015C7014C7013C7012

C7011C7009

C7-9

C7007

C7008

C7005

C7006

C7-8

C7003

C7001

C7001A

C7003A

C7-25

C-7139C-7138

C7-7

C-7077

C7-9

C7023

48

9

C7LE2

C7LL1

E

E

E

E

E

E

E

E

E

E

E

E

E

C7HEX

E

2

2

2

2

7

7

7

7

7

7

1012

22 2220

22

24

24

2

2

2 26

3

3

3

3

28

3

28

28

30 4

4 5

4 5

5

6

6

3232

67

7

9

9

9

3236

11

36

36

11

36

37 37

37

3811

1112

12 12

1213

13 13

14 14

14

38

1438

39

15

39

15

16

16 1617

17 17

18

1919

1010

1921

19

1938

21

37

14

1214

12

1

1

9

15

6

E

E

E

E

EE

EE

EE

E

E

E

VAV-53

VAV-60

VAV-59

VAV-58

VAV-56

VAV-57

VAV-55

VAV-51

VAV-48VAV-30

VAV-31

VAV-32

VAV-33

VAV-36

VAV-34

VAV-37

VAV-39

VAV-38

VAV-35

VAV-40

VAV-42

VAV-41

26

7

POWER TO 600lb PATIENT LIFT 8

E

E

E

E

C7LE1-3

E

E

E

E

22

12

12

14

12

22GFI

1010

10

10

4

+24"+24"

+24"

+24"

+24"

+24"

28

10

10

EF-417

(ABOVE)

C7HEX-25,27,29

C7HEX-1,3,5

AHU-70CONTROLPANEL

7

C7LE1-6

+36" +36"

E 21E

E

21

21 21

E

E

18

18

18 18

+36"

+36"

EF-37

C7HEX-19,21,23

14

VAV-45

CAV-65

E

E

10

10

C7LE2-28

C7LE2-30

13

13

13

13

13

1313

13

13

13

15

15

15

15

15 15

1515

15

15

17

17

17

17

C7LE2-25

POWER TO FD-5

POWER TO FD-9C7LE2-27

GFI

GFI

GFI

GFI

C7LE2-29

POWER TO DOORACTUATOR

10

10

10

10

FV

FV

SVSV

77

7 7

FV

SV

FV

SV

30

30

30

FV

SV

ALT. E-1

1

2828

2E

2828

E2

2E

2E

VAV-51

VAV-45

VAV-53

VAV-48

15

15 15

15

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:10:5

9 P

M

EP-107

PARTIAL SEVENTH FLOOR POWERPLAN

10/05/18 JB HT

1/8" = 1'-0"EP-107

1 PARTIAL SEVENTH FLOOR POWER PLAN 1/8" = 1'-0"EP-107

2 PARTIAL SEVENTH FLOOR POWER PLAN ALTERNATE - 1

1. SURFACE MOUNT RECEPTACLES IN THIS AREA.2. PROVIDE NEW PANEL TO REPLACE EXISTING, PER SINGLE AND PANEL SCHEDULES.

RECONNECT CIRCUITRY REMAINING FROM DEMOLITION.3. PROVIDE POWER AND CONTROLS AS REQUIRED TO RELOCATED ELECTRIC WATER

HEATER. PROVIDE POWER FROM ORIGINAL SOURCE PER MANUFACTURERREQUIREMENTS.

4. TV WALLBOX, CONCEALED BEHIND TELEVISION. COORDINATE FINAL INSTALLEDELEVATION WITH TELEVISION PLACEMENT. RECESS TELEVISION WITHIN TV WALLBOX.PROVIDE POWERFROM DUAL DUPLEX TO JUNCTION BOX ABOVE CEILING.

5. PROVIDE #4 GROUND CABLE FROM EXISTING SIGNAL CLOSET TO NEW CABLE TRAY.REFER TO 'T' DRAWINGS FOR CABLE TRAY.

6. PROVIDE POWER, CONTROLS AND ALL TERMINATIONS FOR AHU PERMANUFACTURER'S INSTRUCTIONS. PROVIDE POWER PER NAMEPLATE DATA. SOURCEFROM C7HEX.

7. PROVIDE POWER, STARTING MEANS AND ALL ASSOCIATED CONTROLS FORRETURN/EXHAUST FAN PER MANUFACTURER'S INSTRUCTIONS. PROVIDE POWER PERNAMEPLATE DATA. PROVIDE 600V 30A 3P, NON-FUSED DISCONNECT.

8. POWER TO PATIENT LIFT. PROVIDE POWER TO JUNCTION BOX ABOVE CEILING TO BEEXTENDED, COORDINATE IN THE FIELD. LABEL JUNCTION BOX CEILING TILE WITHPHENOLIC TAG TO READ "POWER FOR PATIENT LIFT ABOVE".

9. PROVIDE EMERGENCY POWER TO SMOKE DAMPER PER MANUFACTURERSINSTRUCTIONS. DAMPER TO CLOSE UPON SMOKE DETECTION.

10. NON-EMERGENCY FIXTURES ENCLOSED WITHIN THIS REGION ARE CONNECTED TOPANEL C7AC1

DRAWING NOTES:

A. POWER PANEL DOOR SCHEDULES MUST BE UPDATED TO REFLECT THE CHANGES TOTHE ROOM NAMES AND NUMBERS AS A RESULT OF THIS SCOPE OF WORK.

B. CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO ANY FABRICATION ORCONSTRUCTION.

C. CONTRACTOR TO NOTIFY OWNER REPRESENTATIVE OF ANY DISCREPANCIES ANDOBTAIN OWNER APPROVAL FOR ANY CHANGES.

D. ELECTRICAL DEVICE LOCATIONS ARE APPROXIMATE. COORDINATE WITH EQUIPMENTIN AREA AND OWNER FOR FINAL DEVICE LOCATIONS.

E. CONDUIT TO BE FIELD ROUTED. PROVIDE PULL BOXES AS REQUIRED PER NEC ORCONSTRUCTION CONDITIONS.

F. CONTRACTOR TO SIZE CONDUIT AND CONDUCTORS BASED UPON MAXIMUMALLOWABLE LOAD FOR CIRCUIT BREAKER SIZE SHOWN AND DE-RATING FACTORSREQUIRED FOR FILL AND VOLTAGE DROP.

G. PROVIDE SEPARATE INSULATED EQUIPMENT GROUNDING CONDUCTOR WITHIN EACHFEEDER AND BRANCH CIRCUIT RACEWAY. TERMINATE EACH END ON SUITABLE LUG,BUS OR BUSHING.

H. CONTRACTOR TO PROVIDE ALL NECESSARY SUPPORTS TO FACILITATEINSTALLATION OF THEIR DISCIPLINE EQUIPMENT, INDEPENDENT OF OTHERDISCIPLINES.

I. PROVIDE TAMPER-RESISTANT RECEPTACLES IN BUSINESS OFFICES, CORRIDORS,WAITING ROOMS AND THE LIKE IN CLINICS, MEDICAL AND DENTAL OFFICES ANDOUTPATIENT FACILITIES.

GENERAL NOTES:

0

CIRCUITING LEGEND:

CIRCUIT ALL RECEPTACLES TO THE FOLLOWING PANELS.NORMAL: C7LN1EMERGENCY: C7LE2

NOTE:

1. EMERGENCY RECEPTACLES ARE DESIGNATED BY THE LETTER 'E'.2. CIRCUIT FIXTURES TO CIRCUIT NUMBER LISTED IN PLAN WITHIN PANEL ABOVE.3. PROVIDE POWER TO VAVs FROM PANEL C7AC1 AND CIRCUIT INDICATED.

ROOM SCHEDULE - 7TH FLOOR

Number Name

C7-6 CORRIDOR

C7-7 CORRIDOR

C7-8 CORRIDOR

C7-9 CORRIDOR

C7-10

C7-10A SHELL SPACE

C7-11 CORRIDOR

C7-25 FREIGHT ELEVATORS LOBBY

C7001 LOCKERS

C7002 STAFF TLT

C7003 LOCKERS

C7004 STAFF TLT

C7005 BREAK RM /MAIL RM

C7006 HSKP

C7007 WAITING ROOM

C7008 PAT TLT

C7009 RECEPT

C7010 CHECK OUT

C7011

C7012 EXAM

C7013 TYPICAL TEAM RM

C7014 TLT RM

C7015

C7016 EXAM

C7017 EXAM

C7018

C7019 EXAM

C7020 EXAM

C7021

C7022

C7023

C7024

C7025

C7026

C7027 EXAM RM

C7028

C7029

C7030 TEAM RM

C7031

C7032 EXAM RM

C7033 EXAM RM

C7034 STOR

C7035 EXAM/PROC ROOM

C7036 PAT TLT

C7037 EXAM/PROC

C7038 PAT TLT

C7039

C7040 MECH RM

CORRIDOR

EXAM

EXAM

TEAM RM

TEAM RM

EXAM

STOR

ELEC

SOILED HOLDING

TEAM RM

TYPICAL EXAM RM

EXAM RM

EXAM RM

CLEAN STORAGE

EXAM

EXAM

CORRIDOR

EXAM

EXAM

TEAM RM

TEAM RM

EXAM

STOR

ELEC

SOILED HOLDING

TEAM RM

TYPICAL EXAM RM

EXAM RM

EXAM RM

CLEAN STORAGE

EXAM

EXAM

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:10:5

9 P

M

EP-110

PARTIAL TENTH FLOORPENTHOUSE POWER PLAN

10/05/18 JB HT

1/8" = 1'-0"EP-110

1 PARTIAL TENTH FLOOR PENTHOUSE POWER PLAN

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGE

DRAWING NOTES:1. CIRCUIT REINSTALLED PUMPS TO EXISTING CONNECTIONS.

Revisions: Date:

1

1 2

3

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:11:0

0 P

M

EP-601

SINGLE LINE DIAGRAM

10/05/18 JB HT

NORMAL POWER RISER DIAGRAM

DRAWING NOTES:1. REMOVE AND REPLACE EXISTING PANELBOARD. FEEDER TO PANEL TO BE LEFT IN

PLACE FOR RECONNECTION. REFER TO PANELBOARD SCHEDULES.2. PROVIDE NEW PANEL.3. PROVIDE CONDUIT AND WIRE FROM C6LN1 TO C6LN3.

0

1

EP-601

SINGLE LINE DIAGRAMN.T.S.

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

1

1

2

1

1

3

4

(3)#2,#8G, 1"C

DRAWING NOTES:1. REMOVE AND REPLACE EXISTING PANELBOARD. FEEDER TO PANEL TO BE

LEFT IN PLACE FOR RECONNECTION. REFER TO PANELBOARD SCHEDULES.2. DISCONNECT AND REMOVE PANEL.3. PROVIDE CONDUIT AND WIRE FROM C6HEX TO C7HEX.4. PROVIDE NEW PANEL C7HEX.

0

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:11:0

1 P

M

EP-602

SINGLE LINE DIAGRAM

10/05/18 JB HT

EMERGENCY POWER RISER DIAGRAM

1

EP-602

SINGLE LINE DIAGRAMN.T.S.

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:11:0

2 P

M

EP-606a

PANEL SCHEDULE - SIXTH FLOOR

10/05/18 JB HT

* LOCK-OUT / TAG-OUT EXISTING CIRCUIT, DISCONNECT AND WIRING REMOVE IN ITS ENTIRETY. DISCONNECT AND REMOVE ABANDONED CONDUIT. EXISTING TO REMAIN LOADS SHALL BE MAINTAINED, WHERE DISCREPANCIES OR UNACCOUNTED FORLOADS EXIST ON CIRCUITS TO BE DEMOLISHED, MAKE NOTE AND NOTIFY VA PROJECT MANAGEMENT OF THE ISSUE.

Notes:

Total Est. Demand Current: 53 A

Total Conn. Current: 50 A

Spare 9330 VA 100.00% 9330 VA Total Est. Demand: 19038 VA

Receptacle 5220 VA 100.00% 5220 VA Total Conn. Load: 18140 VA

Existing Load 3590 VA 125.00% 4488 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 46 A 47 A 59 A

Total Load: 5470 VA 5650 VA 7020 VA

41 RECPTS COPY MACHINE - C6034 RECPTS 6027, 28, 30, 32 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare RECPTS N. CORR. - C6011 42

39 -- LINEN CHUTE - C6019 (EXISTING) 20 A 1 0.2 kVA 0.0 kVA 1 20 A Spare C6009 40

37 -- NURSE CALL PANEL - C6004 (EXISTING) 20 A 1 0.5 kVA 0.0 kVA 1 20 A PRINTER (EXISTING) -- 38

35 -- PBUs - C6011, 12V 20 A 1 1.1 kVA 0.0 kVA 1 20 A PBUs - C6027, 28 (EXISTING) -- 36

33 C6013, 6009, 6012, 6011 RECPTS C6021, 22, 23, 24, 25, 26 20 A 1 1.1 kVA 0.0 kVA 1 20 A PBUs - C6018, 19 (EXISTING) -- 34

31 -- PBUs - C6011, 12 (EXISTING) 20 A 1 1.1 kVA 0.0 kVA 1 20 A PBUs - C6027, 28 (EXISTING) -- 32

29 -- HEATER (EXISTING) 20 A 1 0.8 kVA 0.0 kVA 1 20 A Spare RECPTS E. & N. - C6022, 25 30

27 -- HOT WATER - C6015 (EXISTING) 20 A 1 0.5 kVA 0.0 kVA 1 20 A PBU - C6016, 25, 30 RECPTS N, S C6016, 25, 30 28

25 RECPTS W. C6014 PBU - C6014 (EXISTING) 20 A 1 1.1 kVA 0.0 kVA 1 20 A PBU - C6016, 25, 30 (EXISTING) RECPTS N, S - C6016, 25, 30 26

23 -- PBU - C6006 (EXISTING) 20 A 1 1.1 kVA 0.0 kVA 1 20 A Spare RECPTS - C6022, 24 24

21 -- PBU - C6008 (EXISTING) 20 A 1 1.1 kVA 0.0 kVA 1 20 A IN USE - C6022 -- 22

19 RECPTS - C6014 RECPTS C6015, 16, 17, 19 20 A 1 1.1 kVA 0.0 kVA 1 20 A Spare RECPTS - C6033 20

17 -- IN USE 20 A 1 1.0 kVA 0.0 kVA 1 20 A Spare RECPTS - C6025 18

15 -- PUMPS (EXISTING) 20 A 1 0.5 kVA 0.0 kVA 1 20 A Spare LTS - C6025, 26, 27 16

13 -- Booster - C6015, C6013 (EXISTING) 20 A 1 0.5 kVA 0.0 kVA 1 20 A Spare LTS - C6028, 29, 30 14

11 -- RECPTS C6008, 09, 10, 11, 13, 14 20 A 1 1.1 kVA 0.0 kVA 1 20 A Spare LTS - C6025, 27, 28, 30 12

9 LIGHTS - C6022, 23, 24 RECPTS C6001, 02, 03, 05 20 A 1 1.1 kVA 0.1 kVA 1 20 A FD-7 RECPTS - C6032 10

7 -- C6004 - RECPTS W.(EXISTING) 20 A 1 0.0 kVA 0.1 kVA 1 20 A FD-6 LTS - C6031, 32, 33, 34 8

5 LTS C6004, 05, 41 LTS C6003, 37, 38, 39, 40 (EXISTING) 20 A 1 1.1 kVA 0.1 kVA 1 20 A FD-8 LTS - C6009, 10, 11 6

3 -- RECPTS/LTS. AIR HANDLER (EXISTING) 20 A 1 1.1 kVA 0.1 kVA 1 20 A FD-1, FD-2 LTS - C6008, 12, 13, 15, 17 4

1 RECPT 6041 RECPTS C6037,6038,6040 E,W,S... 20 A 1 1.1 kVA 0.1 kVA 1 20 A FD-3, FD-4 LTS - C6006, 16, 19, 21 2

CKT*

Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*

Demolished Circuit Description CKT

Notes: FEED THRU LUGS

Enclosure: Type 1

Mounting: Surface Wires: 4 Mains: 225 A

Supply From: Phases: 3 Mains Type: MCB

Location: MECH RM C6018 Volts: 120/208 Wye A.I.C. Rating: 10,000 A

New Branch Panel: C6LE2

* LOCK-OUT / TAG-OUT EXISTING CIRCUIT, DISCONNECT AND WIRING REMOVE IN ITS ENTIRETY. DISCONNECT AND REMOVE ABANDONED CONDUIT. EXISTING TO REMAIN LOADS SHALL BE MAINTAINED, WHERE DISCREPANCIES OR UNACCOUNTED FORLOADS EXIST ON CIRCUITS TO BE DEMOLISHED, MAKE NOTE AND NOTIFY VA PROJECT MANAGEMENT OF THE ISSUE.

Notes:

Spare 15864 VA 100.00% 15864 VA Total Est. Demand Current: 126 A

Receptacle 34020 VA 64.70% 22010 VA Total Conn. Current: 157 A

Lighting - Dwelling Unit 36 VA 100.00% 36 VA Total Est. Demand: 45291 VA

Lighting 4131 VA 100.00% 4131 VA Total Conn. Load: 56651 VA

Existing Load 2600 VA 125.00% 3250 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 157 A 161 A 155 A

Total Load: 18779 VA 19255 VA 18616 VA

41 -- -- -- -- 12.1... 0.0 kVA 1 20 A Spare -- 42

39 -- -- -- -- 11.4... 0.0 kVA 1 20 A Spare -- 40

37 C6LN3 125 A 3 10.8... 0.0 kVA 1 20 A Spare -- 38

35 -- Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare -- 36

33 -- Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare -- 34

31 -- C6092 - UNION (EXISTING) 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare -- 32

29 -- NORTH DRINKING FOUNTAINS... 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare -- 30

27 -- RECPTS PBU - C6058 PLUG MOLD... 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare -- 28

25 -- Spare 20 A 1 0.0 kVA 0.9 kVA 1 20 A SOUTH DRINKING FOUNTAINS... -- 26

23 -- Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare GENERAL RECPTS - C6006 24

21 -- RECPTS - C6035 (EXISTING) 30 A 1 0.9 kVA 0.0 kVA 1 20 A Spare GFCI - C6006 22

19 -- RECPTS - C6035 (EXISTING) 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare COFFEE MACHINE - C6006 20

17 -- COMPUTER - C6035 (EXISTING) 20 A 1 0.9 kVA 0.9 kVA 1 20 A VAVs - 6th FLR RECPTS - C6001 18

15 COMPUTER - C6003 VAVs - 6th FLR 20 A 1 0.8 kVA 0.8 kVA 1 20 A VAVs - 6th FLR 16

13 COMPUTER - C6003 LTS - CORR NORTH 20 A 1 0.8 kVA 0.9 kVA 1 20 A RECPTS - C6095 (EXISTING) -- 14

11 LTS - CORR RT WING 20 A 1 1.6 kVA 0.5 kVA 1 20 A LTS (EXISTING) -- 12

9 LTS. - SOUTH CORR 20 A 1 1.8 kVA 0.9 kVA 1 20 A RECPTS - C6094, 95, 93 (EXISTING) -- 10

7 -- RECPTS - C6063 (EXISTING) 20 A 1 0.9 kVA 0.9 kVA 1 20 A RECPTS - 6092 (EXISTING) -- 8

5 -- RECPTS - C6059 (EXISTING) 20 A 1 0.9 kVA 0.9 kVA 1 20 A RECPTS -- 6

3 -- IN USE 20 A 1 1.0 kVA 0.9 kVA 1 20 A RECPTS -- 4

1 -- RECPTS - C6058 (EXISTING) 20 A 1 0.9 kVA 0.9 kVA 1 20 A RECPTS -- 2

CKT*

Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*

Demolished Circuit Description CKT

Notes:

Enclosure: Type 1

Mounting: Surface Wires: 4 Mains: 225 A

Supply From: Phases: 3 Mains Type: MCB

Location: MECH. ROOM C-6033 Volts: 120/208 Wye A.I.C. Rating: 31,000 A

New Branch Panel: C6LN1

* LOCK-OUT / TAG-OUT EXISTING CIRCUIT, DISCONNECT AND WIRING REMOVE IN ITS ENTIRETY. DISCONNECT AND REMOVE ABANDONED CONDUIT. EXISTING TO REMAIN LOADS SHALL BE MAINTAINED, WHERE DISCREPANCIES OR UNACCOUNTED FORLOADS EXIST ON CIRCUITS TO BE DEMOLISHED, MAKE NOTE AND NOTIFY VA PROJECT MANAGEMENT OF THE ISSUE.

Notes:

Total Est. Demand Current: 60 A

Spare 16854 VA 100.00% 16854 VA Total Conn. Current: 58 A

Power 500 VA 100.00% 500 VA Total Est. Demand: 21572 VA

Lighting 383 VA 100.00% 383 VA Total Conn. Load: 20805 VA

Existing Load 3068 VA 125.00% 3835 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 48 A 54 A 73 A

Total Load: 5730 VA 6381 VA 8694 VA

41 -- PBU C6160 (EXISTING) 30 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS C8085 (EXISTING) RECPTS C6001 42

39 -- PBU/RECPTS C6160 (EXISTING) 30 A 1 0.8 kVA 0.0 kVA 1 20 A Spare PBU C6001 40

37 -- RECPT 9TH FLOOR (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS C7025 (EXISTING) PBU C6001 38

35 -- PBU/RECPTS C6160 (EXISTING) 30 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS C6096 (EXISTING) RECPTS C6002 36

33 -- PBU/RECPTS C6160 (EXISTING) 30 A 1 0.8 kVA 0.0 kVA 1 20 A Spare RECPTS C6002 34

31 -- FCU IT 6,7,8,9th FLR (EXISTING) 20 A 1 0.5 kVA 0.0 kVA 1 20 A Spare RECPTS C6002 32

29 -- RECPTS C6160 (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 30 A RECPTS CORRIDOR (EXISTING) -- 30

27 RECPTS C6001 Spare 20 A 1 0.0 kVA 0.8 kVA 1 20 A RECPTS CORRIDOR (EXISTING) -- 28

25 RECPTS C6001 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare RECPTS C6003, 06 26

23 RECPTS C6002 Spare 20 A 1 0.0 kVA 0.8 kVA 1 20 A RECPTS A650 (EXISTING) -- 24

21 RECPTS C6002, 05 Spare 20 A 1 0.0 kVA 0.8 kVA 1 20 A RECPTS A651a (EXISTING) -- 22

19 RECPTS C6001, 03 Spare 20 A 1 0.0 kVA 0.8 kVA 1 20 A RECPTS A651 (EXISTING) -- 20

17 -- RECPTS C6061, 68, 91 (EXISTING) 20 A 1 0.8 kVA 0.5 kVA 1 20 A LTS C6111 (EXISTING) -- 18

15 -- RECPTS C6059 (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS C6093, 94, 95 (EXISTING) -- 16

13 -- RECPTS C6061 (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS C6160 (EXISTING) -- 14

11 LTS C6009 RECPTS C5130 (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS C6058, 59 (EXISTING) -- 12

9 -- Spare 20 A 1 0.0 kVA 0.8 kVA 1 20 A RECPTS C6160 (EXISTING) -- 10

7 -- Spare 20 A 1 0.0 kVA 0.5 kVA 1 20 A TX-C-5 (EXISTING) -- 8

5 LTS C6003, 04, 05 Spare 20 A 1 0.0 kVA 0.5 kVA 1 20 A LTS C6043 (EXISTING) -- 6

3 LTS C6002 JUNCTION BOX - SMOKE DAMPER 20 A 1 0.5 kVA 0.5 kVA 1 20 A LTS C6043 (EXISTING) -- 4

1 -- EMERGENCY LTS. - 6TH FLR 20 A 1 0.4 kVA 0.5 kVA 1 20 A LTS A651 (EXISTING) -- 2

CKT*

Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*

Demolished Circuit Description CKT

Notes: FEED THRU LUGS

Enclosure: Type 1

Mounting: Surface Wires: 4 Mains: 225 A

Supply From: Phases: 3 Mains Type: MCB

Location: MECH. ROOM C-6033 Volts: 120/208 Wye A.I.C. Rating: 10,000 A

New Branch Panel: C6LE1 0 DRAWING NOTES:1. REPLACE EXISTING PANEL. RECONNECT EXISTING FEEDER

AND LOADS AS SHOWN.2. MAINTAIN EXISTING LOADS REMAINING ON CIRCUIT.

EXTEND CIRCUITRY AND RECONNECT TO EXISTING LOADSAS REQUIRED.

3. PROVIDE NEW BREAKER IN AVAILABLE SPACE.

1 1

1

Calculated Existing Calculated Existing

Calculated Existing

2

2 2

2

2

2

2

2

Notes:

Total Est. Demand Current: 62 A

Total Conn. Current: 62 A

Total Est. Demand: 51390 VA

Total Conn. Load: 51390 VA

Spare 51390 VA 100.00% 51390 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 62 A 62 A 62 A

Total Load: 17130 VA 17130 VA 17130 VA

23 -- -- -- 0.5 kVA 8.2 kVA -- -- -- 24

21 -- -- -- 0.5 kVA 8.2 kVA -- -- -- 22

19 SPARE 15 A 3 0.5 kVA 8.2 kVA 3 100 A C7HEX 20

17 -- -- -- 0.5 kVA 0.5 kVA -- -- -- 18

15 -- -- -- 0.5 kVA 0.5 kVA -- -- -- 16

13 EF-32 (EXISTING) 15 A 3 0.5 kVA 0.5 kVA 3 15 A SPARE 14

11 -- -- -- 0.6 kVA 0.6 kVA -- -- -- 12

9 -- -- -- 0.6 kVA 0.6 kVA -- -- -- 10

7 PUMP 1 (EXISTING) 20 A 3 0.6 kVA 0.6 kVA 3 20 A PUMP 2 (EXISTING) 8

5 -- -- -- 6.3 kVA 0.0 kVA -- -- Space 6

3 -- -- -- 6.3 kVA 0.0 kVA -- -- Space 4

1 AHU SF-1 (EXISTING) 90 A 3 6.3 kVA 0.0 kVA -- -- Space 2

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Notes:

Enclosure: Type 1

Mounting: Surface Wires: 3 Mains: 150 A

Supply From: Phases: 3 Mains Type: MCB

Location: MECH. ROOM C6031 Volts: 480 Delta A.I.C. Rating: 35,000 A

Exist Branch Panel: C6HEX

3

Calculated Existing

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:11:0

3 P

M

EP-606b

PANEL SCHEDULE - SIXTH FLOOR

10/05/18 JB HT

Notes:

Total Est. Demand Current: 62 A

Total Conn. Current: 95 A

Total Est. Demand: 22260 VA

Receptacle 34020 VA 64.70% 22010 VA Total Conn. Load: 34220 VA

Existing Load 200 VA 125.00% 250 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 90 A 95 A 101 A

Total Load: 10800 VA 11360 VA 12060 VA

53 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 54

51 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 52

49 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 50

47 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 48

45 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare 46

43 RECPTS C6004 20 A 1 0.5 kVA 0.0 kVA 1 20 A Spare 44

41 RECPTS C6030 20 A 1 1.1 kVA 0.9 kVA 1 20 A RECPTS C6032 42

39 RECPTS C6029 20 A 1 0.9 kVA 0.9 kVA 1 20 A RECPTS C6030 40

37 RECPTS C6026, 27 20 A 1 0.7 kVA 0.7 kVA 1 20 A RECPTS C6028, 29 38

35 RECPTS C6020 20 A 1 0.4 kVA 0.7 kVA 1 20 A RECPTS C6024, 25 36

33 RECPTS C6021, 22 20 A 1 0.9 kVA 0.7 kVA 1 20 A RECPTS C6022, 23 34

31 RECPTS C6019 20 A 1 0.7 kVA 0.9 kVA 1 20 A RECPTS C6019 32

29 RECPTS C6019 20 A 1 0.2 kVA 1.1 kVA 1 20 A RECPTS C6019 30

27 RECPTS C6019 20 A 1 0.9 kVA 1.1 kVA 1 20 A RECPTS C6019 28

25 RECPTS C6017 20 A 1 0.7 kVA 0.9 kVA 1 20 A RECPTS C6019, 17 26

23 RECPTS C6016 20 A 1 0.7 kVA 1.1 kVA 1 20 A RECPTS C6016, 17, GFI WTR COOLER 24

21 RECPTS C6015 20 A 1 1.1 kVA 1.1 kVA 1 20 A RECPTS C6015, 16 22

19 RECPTS C6012, 13 20 A 1 1.1 kVA 0.7 kVA 1 20 A RECPTS C6013, 14 20

17 RECPTS C6010 20 A 1 1.1 kVA 0.9 kVA 1 20 A RECPTS C6012 18

15 RECPTS C6009 20 A 1 1.1 kVA 0.0 kVA 1 20 A Spare 16

13 RECPTS C6008, CORR. 6-24 20 A 1 1.1 kVA 0.5 kVA 1 20 A RECPTS C6008, CORR 6-24 14

11 RECPTS C6005, CORR.6-24 20 A 1 0.9 kVA 1.1 kVA 1 20 A RECPTS C6008 12

9 RECPTS C6004 20 A 1 0.2 kVA 1.1 kVA 1 20 A RECPTS C6004, 06, 07 10

7 GFI - FRIDGE C6004 20 A 1 0.2 kVA 0.2 kVA 1 20 A RECPTS C6004 8

5 RECPTS C6002 20 A 1 0.9 kVA 1.1 kVA 1 20 A RECPTS C6003, 02 6

3 RECPTS C6001, 02 20 A 1 0.9 kVA 0.5 kVA 1 20 A RECPTS C6001 4

1 RECPTS C6001, 02 20 A 1 1.1 kVA 0.7 kVA 1 20 A RECPTS C6001 2

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Notes: GFI - PROVIDE GFCI CIRCUIT BREAKER.

Enclosure: Type 1

Mounting: Surface Wires: 4 Mains: 125 A

Supply From: C6LN1 Phases: 3 Mains Type: MCB

Location: MECH RM C6018 Volts: 120/208 Wye A.I.C. Rating: 10,000 A

New Branch Panel: C6LN3

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:11:0

5 P

M

EP-607a

PANEL SCHEDULE - SEVENTHFLOOR

10/05/18 JB HT

* LOCK-OUT / TAG-OUT EXISTING CIRCUIT, DISCONNECT AND WIRING REMOVE IN ITS ENTIRETY. DISCONNECT AND REMOVE ABANDONED CONDUIT. EXISTING TO REMAIN LOADS SHALL BE MAINTAINED, WHERE DISCREPANCIES OR UNACCOUNTED FORLOADS EXIST ON CIRCUITS TO BE DEMOLISHED, MAKE NOTE AND NOTIFY VA PROJECT MANAGEMENT OF THE ISSUE.

Notes:

Spare 18781 VA 100.00% 18781 VA Total Est. Demand Current: 83 A

Receptacle 8280 VA 100.00% 8280 VA Total Conn. Current: 83 A

Lighting - Dwelling Unit 640 VA 100.00% 640 VA Total Est. Demand: 30014 VA

Lighting 1938 VA 100.00% 1938 VA Total Conn. Load: 29939 VA

Existing Load 300 VA 125.00% 375 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 83 A 90 A 78 A

Total Load: 9879 VA 10713 VA 9324 VA

41 -- RECPTS C7006 (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS A741 (EXISTING) -- 42

39 FRIDGE - BREAK ROOM RECPTS C7030 20 A 1 0.4 kVA 1.5 kVA 1 20 A LTS- CORR RT WNG, RCPTN, WTNG RM RECPTS C-7003 40

37 RECPTS C7006 RECPTS C7026 20 A 1 0.7 kVA 0.7 kVA 1 20 A RECEPTS C7-9, C7026, 30 RECPTS C-7003 38

35 -- RECPTS C7179 (EXISTING) 20 A 1 0.8 kVA 0.9 kVA 1 20 A RECEPTS C7021, 22 RECPTS C-7003 36

33 -- RECPTS C7177 (EXISTING) 20 A 1 0.8 kVA 1.1 kVA 1 20 A LTS. - NORTH WING, RCPTN, WTNG RM FRIDGE - BREAK RM 34

31 -- RECPTS C7176 (EXISTING) 20 A 1 0.8 kVA 1.1 kVA 1 20 A RECEPTS C7018 RECPTS C7057 32

29 -- RECPTS C7176 (EXISTING) 20 A 1 0.8 kVA 0.5 kVA 1 20 A RECEPTS C7013, 14 LTS C7001 30

27 -- RECPTS C7179 (EXISTING) 20 A 1 0.8 kVA 0.7 kVA 1 20 A RECEPTS C7-11, C7012, 13 LTS C7001 28

25 -- RECPTS C7176 (EXISTING) 20 A 1 0.8 kVA 0.4 kVA 1 20 A RECPTS C7009 RECPTS C7004 26

23 -- RECPTS C7042, 43 (EXISTING) 20 A 1 0.8 kVA 0.4 kVA 1 20 A RECPTS C7005, 06 RECPTS C7058 24

21 -- RECPTS CORR. (EXISTING) 30 A 1 0.8 kVA 1.1 kVA 1 20 A RECPTS C7005 RECPTS C7004 22

19 -- RECPTS C7141 (EXISTING) 20 A 1 0.8 kVA 0.2 kVA 1 20 A GFI ICE MACHINE - C7005 RECPTS C7004 20

17 -- RECPTS C7141 (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 20 A RECPTS A745 (EXISTING) -- 18

15 -- RECPTS C7141 (EXISTING) 20 A 1 0.8 kVA 0.8 kVA 1 30 A RECPTS A745 (EXISTING) -- 16

13 -- LTS C7141 (EXISTING) 20 A 1 0.5 kVA 0.8 kVA 1 20 A RECPTS A746 (EXISTING) -- 14

11 -- FCU (EXISTING) 20 A 1 0.5 kVA 0.2 kVA 1 20 A MCRWV - C7005 LTS. C7179 12

9 -- FCU (EXISTING) 20 A 1 0.5 kVA 0.2 kVA 1 20 A GFI FRIDGE - C7005 LTS. C7002 10

7 RECPTS C7001, 03A, 03 20 A 1 1.3 kVA 0.5 kVA 1 20 A LTS DMS C7042, 43, 44, 45 (EXISTING) -- 8

5 -- FCU (EXISTING) 20 A 1 0.5 kVA 0.8 kVA 1 20 A RECPTS A745 (EXISTING) -- 6

3 -- FCU (EXISTING) 20 A 1 0.5 kVA 0.8 kVA 1 20 A RECPTS A746 (EXISTING) -- 4

1 -- FCU (EXISTING) 20 A 1 0.5 kVA 0.8 kVA 1 20 A RECPTS CORR. (EXISTING) -- 2

CKT*

Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*

Demolished Circuit Description CKT

Notes: FEED THRU LUGS, GFI - PROVIDE GFCI CIRCUIT BREAKER.

Enclosure: Type 1

Mounting: Surface Wires: 4 Mains: 225 A

Supply From: Phases: 3 Mains Type: MCB

Location: ELECTR C-7059 Volts: 120/208 Wye A.I.C. Rating: 31,000 A

New Branch Panel: C7LN1

* LOCK-OUT / TAG-OUT EXISTING CIRCUIT, DISCONNECT AND WIRING REMOVE IN ITS ENTIRETY. DISCONNECT AND REMOVE ABANDONED CONDUIT. EXISTING TO REMAIN LOADS SHALL BE MAINTAINED, WHERE DISCREPANCIES OR UNACCOUNTED FORLOADS EXIST ON CIRCUITS TO BE DEMOLISHED, MAKE NOTE AND NOTIFY VA PROJECT MANAGEMENT OF THE ISSUE.

Notes:

Spare 20720 VA 100.00% 20720 VA Total Est. Demand Current: 61 A

Power 0 VA 0.00% 0 VA Total Conn. Current: 60 A

Lighting - Dwelling Unit 54 VA 100.00% 54 VA Total Est. Demand: 21897 VA

Lighting 483 VA 100.00% 483 VA Total Conn. Load: 21769 VA

Existing Load 512 VA 125.00% 640 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 55 A 64 A 65 A

Total Load: 6630 VA 7507 VA 7630 VA

41 RECPTS. C7014 Spare 20 A 1 0.0 kVA 0.5 kVA 1 20 A SIGNAL CIRCUIT (EXISTING) -- 42

39 RECPTS. C7014 Spare 20 A 1 0.0 kVA 0.9 kVA 1 20 A RECPTS CORR. (EXISTING) -- 40

37 RECPTS. - C7004 Spare 20 A 1 0.0 kVA 0.5 kVA 1 20 A LIGHTING (EXISTING) -- 38

35 -- RECPTS A757 (EXISTING) 20 A 1 0.9 kVA 0.5 kVA 1 20 A NURSE CALL (EXISTING) -- 36

33 RECPTS. C7032, 7043 Spare 20 A 1 0.0 kVA 0.5 kVA 1 20 A LTS CORRIDOR (EXISTING) -- 34

31 RECPTS. C7006. LTS C7083 (EXISTING) 20 A 1 0.5 kVA 0.9 kVA 1 20 A RECPTS S. CORRIDOR (EXISTING) -- 32

29 -- RECPTS C7046 (EXISTING) 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare RECPTS C7025 30

27 -- RECPTS C7004, 55 (EXISTING) 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare LTS C7021, 24 28

25 RECPTS. C7012. LTS. C7012 Spare 20 A 1 0.0 kVA 0.5 kVA 1 20 A LTS C7008 (EXISTING) -- 26

23 RECPTS C7008 Spare 20 A 1 0.0 kVA 0.9 kVA 1 20 A RECPTS C7050 LOBBY (EXISTING) -- 24

21 -- RECPTS C7047,46,42,CORR. W (EXIST) 20 A 1 0.9 kVA 0.9 kVA 1 20 A RECPTS A755 (EXISTING) -- 22

19 RECPTS C7057 Spare 20 A 1 0.0 kVA 0.0 kVA 1 20 A Spare RECPTS C7050 20

17 -- RECPTS C7007, 141A (EXISTING) 20 A 1 0.9 kVA 1.0 kVA 1 20 A RECPTS 7056, LTS 84, 85, 86 (EXISTING) -- 18

15 -- RECPTS C7001, 04, 06, 141A (EXISTING) 20 A 1 0.9 kVA 0.9 kVA 1 20 A RECPTS C7141 (EXISTING) -- 16

13 -- RECPTS C7141, 18, 20 (EXISTING) 20 A 1 0.9 kVA 0.0 kVA 1 20 A Spare LTS C7001, 04, 06. RECPTS CORR. W. 14

11 -- RECPTS C7141 (EXISTING) 20 A 1 0.9 kVA 0.5 kVA 1 20 A LTS C7141 (EXISTING) -- 12

9 -- RECPTS C7141 (EXISTING) 20 A 1 0.9 kVA 0.5 kVA 1 20 A LTS A745 (EXISTING) -- 10

7 -- RECPTS C7141A (EXISTING) 20 A 1 0.9 kVA 1.0 kVA 1 20 A LTS A743, A744 RECPTS C7079 (EXIST) -- 8

5 -- RECPTS C7141 (EXISTING) 20 A 1 0.9 kVA 0.0 kVA 1 20 A AHU-70 CONTROL PANEL RECPTS C7042, 46, 47 6

3 LTS 7004, 55, 57, 58 RECPTS 7057, 58 JUNCTION BOX - SMOKE DAMPER 20 A 1 0.0 kVA 0.5 kVA 1 20 A LTS ELECT. CLOSET 7059 (EXISTING) -- 4

1 -- IN USE (EXISTING) 70 A 1 1.0 kVA 0.5 kVA 1 20 A LTS. EMERGENCY - 7TH FLR LTS C7041, 42, 46 2

CKT*

Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*

Demolished Circuit Description CKT

Notes: FEED THRU LUGS

Enclosure: Type 1

Mounting: Surface Wires: 4 Mains: 225 A

Supply From: Phases: 3 Mains Type: MCB

Location: ELECTR C-7059 Volts: 120/208 Wye A.I.C. Rating: 10,000 A

New Branch Panel: C7LE1

Notes:

Spare 4512 VA 100.00% 4512 VA Total Est. Demand Current: 33 A

Receptacle 3060 VA 100.00% 3060 VA Total Conn. Current: 31 A

Lighting - Dwelling Unit 256 VA 100.00% 256 VA Total Est. Demand: 11735 VA

Lighting 1407 VA 100.00% 1407 VA Total Conn. Load: 11235 VA

Existing Load 2000 VA 125.00% 2500 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 31 A 29 A 34 A

Total Load: 3662 VA 3530 VA 4032 VA

17 VAVs - 7th FLR 20 A 1 0.3 kVA 0.0 kVA 1 20 A Spare -- 18

15 VAVs - 7th FLR 20 A 1 0.8 kVA 0.0 kVA 1 20 A Spare -- 16

13 VAVs - 7th FLR 20 A 1 0.8 kVA 0.9 kVA 1 20 A RECPTS C7007 Spare 14

11 LTS - SOUTH CORR & WNG 20 A 1 1.7 kVA 1.1 kVA 1 20 A RECPTS C7007 Spare 12

9 -- FCUs EAST (EXISTING) 20 A 1 0.5 kVA 1.3 kVA 1 20 A RECPTS C7039, 37A, 36 Spare 10

7 -- LTS CORR. N. & E. (EXISTING) 20 A 1 0.5 kVA 0.5 kVA 1 20 A FCU C7121 (EXISTING) -- 8

5 -- FCUs SOUTH (EXISTING) 20 A 1 0.5 kVA 0.5 kVA 1 20 A FCUs WEST (EXISTING) -- 6

3 -- FCUs EAST (EXISTING) 20 A 1 0.5 kVA 0.5 kVA 1 20 A FCUs NORTHWEST (EXISTING) -- 4

1 -- FCUs EAST CENTER (EXISTING) 20 A 1 0.5 kVA 0.5 kVA 1 20 A FCUs W. CENTER 7001 (EXISTING) -- 2

CKT*

Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*

Demolished Circuit Description CKT

Notes:

Enclosure: Type 1

Mounting: Surface Wires: 4 Mains: 250 A

Supply From: Phases: 3 Mains Type: MLO

Location: ELECTR C-7059 Volts: 120/208 Wye A.I.C. Rating: 10,000 A

Existing Branch Panel: C7AC1

* LOCK-OUT / TAG-OUT EXISTING CIRCUIT, DISCONNECT AND WIRING REMOVE IN ITS ENTIRETY. DISCONNECT AND REMOVE ABANDONED CONDUIT. EXISTING TO REMAIN LOADS SHALL BE MAINTAINED, WHERE DISCREPANCIES OR UNACCOUNTED FORLOADS EXIST ON CIRCUITS TO BE DEMOLISHED, MAKE NOTE AND NOTIFY VA PROJECT MANAGEMENT OF THE ISSUE.

Notes:

Total Est. Demand Current: 52 A

Total Conn. Current: 58 A

Spare 5332 VA 100.00% 5332 VA Total Est. Demand: 18653 VA

Receptacle 14580 VA 84.29% 12290 VA Total Conn. Load: 20737 VA

Existing Load 825 VA 125.00% 1031 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 62 A 65 A 49 A

Total Load: 7222 VA 7580 VA 5935 VA

29 Existing Load 20 A 1 0.5 kVA 0.1 kVA 1 20 A PATIENT LIFT PWR 30

27 Spare FD-9 20 A 1 0.1 kVA 0.1 kVA 1 20 A PATIENT LIFT PWR 28

25 RECPTS C7048 FD-5 20 A 1 0.1 kVA 0.5 kVA 1 20 A LTS IN USE (EXISTING) -- 26

23 OVERBED LTS, SP, RECPTS. C7032 CORRIDOR C7-9 20 A 1 0.0 kVA 0.5 kVA 1 20 A PUMP C7025 (EXISTING) -- 24

21 LTS C7040, 41 RECPTS - C7037 20 A 1 1.5 kVA 1.1 kVA 1 20 A RECPTS CORR. (EXISTING) -- 22

19 LTS C7040, 41, 47, 46 RECPTS C7035, 37 20 A 1 0.9 kVA 1.1 kVA 1 20 A RECPTS CORR. N. (EXISTING) -- 20

17 RECPTS C7046 RECPTS C7033 20 A 1 0.7 kVA 1.1 kVA 1 20 A RECPTS C7035 RECPTS C7046, 48 18

15 LTS C7038 RECPTS C7031 20 A 1 0.7 kVA 0.7 kVA 1 20 A RECPTS C7032 RECPTS C7046, 48 16

13 RECPTS C7049 RECPTS C7028 20 A 1 0.7 kVA 0.9 kVA 1 20 A RECPTS C7029, 30 RECPTS C7028, 29, 30 14

11 RECPTS C7042 RECPTS C7022, 26, 27 20 A 1 0.7 kVA 0.9 kVA 1 20 A RECPTS C7026, 27, 28 RECPTS C7026, 30, 49 12

9 RECPTS C7047, C7046 RECPTS C7020, 21 20 A 1 0.9 kVA 1.1 kVA 1 20 A RECPTS C9051, MCRWV (EXISTING) -- 10

7 RECPTS C7048, 49, 51 RECPTS C7019 20 A 1 0.5 kVA 1.1 kVA 1 20 A RECPTS CORR. (EXISTING) -- 8

5 RECPTS C7038 RECPTS C7016 20 A 1 0.5 kVA 0.9 kVA 1 20 A RECPTS C7017, 18 LTS C7025, 26, 27. RECPTS C7028 6

3 RECPTS C7040 RECPTS C7011, 12 20 A 1 0.9 kVA 0.5 kVA 1 20 A RECPTS C7015 LTS C7008, 21 4

1 LTS C7036,37,39 RECPTS C7038 RECPTS C7005 20 A 1 0.4 kVA 1.1 kVA 1 20 A RECPTS C7009 LTS C7032, 06, 07, 08 2

CKT*

Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*

Demolished Circuit Description CKT

Notes: FEED THRU LUGS

Enclosure: Type 1

Mounting: Surface Wires: 4 Mains: 150 A

Supply From: Phases: 3 Mains Type: MCB

Location: ELEC C7025 Volts: 120/208 Wye A.I.C. Rating: 10,000 A

New Branch Panel: C7LE2

0 DRAWING NOTES:1. REPLACE EXISTING PANEL. RECONNECT EXISTING FEEDER

AND LOADS AS SHOWN.2. MAINTAIN EXISTING LOADS REMAINING ON CIRCUIT. EXTEND

CIRCUITRY AND RECONNECT TO EXISTING LOADS ASREQUIRED.

2

Calculated Existing

Calculated Existing

Calculated Existing

CalculatedExisting

1

1 1

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

3

BID DOCUMENTS

FULLY SPRINKLERED

Services

Engineeringand FacilitiesManagement

U.S. Departmentof Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORDF F E I n cEngineering and Technical Services420 Springfield PikeWyoming OH 45215513-5322-0956

CONSULTANT

321 4 5 6 7 8 9 10

C H A M P L I N A R C H I T E C T U R E720 East Pete Rose WaySuite 100Cincinnati OH 45202513-241-4474 INDIANAPOLIS VAMC

LEVEL 6 & 7 RENOVATIONSBuilding #1

#583-14-129

C:\U

sers

\FF

E-0

1\D

ocum

ents

\India

napolis

_E

lectr

ical_

harika.tum

mala

@ffe-s

erv

.com

.rvt

10/5

/2018 4

:11:0

5 P

M

EP-607b

PANEL SCHEDULE - SEVENTHFLOOR

10/05/18 JB HT

* LOCK-OUT / TAG-OUT EXISTING CIRCUIT, DISCONNECT AND WIRING REMOVE IN ITS ENTIRETY. DISCONNECT AND REMOVE ABANDONED CONDUIT. EXISTING TO REMAIN LOADS SHALL BE MAINTAINED, WHERE DISCREPANCIES OR UNACCOUNTED FORLOADS EXIST ON CIRCUITS TO BE DEMOLISHED, MAKE NOTE AND NOTIFY VA PROJECT MANAGEMENT OF THE ISSUE.** REFEED RELOCATED EQUIPMENT FROM SOURCE.

Notes:

Total Est. Demand Current: 65 A

Total Conn. Current: 65 A

Spare 8080 VA 100.00% 8080 VA Total Est. Demand: 23320 VA

Receptacle 180 VA 100.00% 180 VA Total Conn. Load: 23320 VA

Power 15060 VA 100.00% 15060 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 66 A 66 A 63 A

Total Load: 7860 VA 7860 VA 7600 VA

29 -- -- -- -- 4.1 kVA 30

27 -- -- -- -- 4.1 kVA 28

25 EWH-1 EWH-1 6th FLR MECH RM. ** 50 A 3 4.1 kVA 0.0 kVA -- -- -- -- 26

23 -- -- -- -- 0.4 kVA 0.0 kVA -- -- -- -- 24

21 -- -- -- -- 0.4 kVA 0.0 kVA 3 60 A SWITCHED OFF (EXISTING) -- 22

19 BP-2 20 A 3 0.4 kVA 0.4 kVA -- -- -- -- 20

17 -- PUMP 20 A 1 0.5 kVA 0.4 kVA -- -- -- -- 18

15 -- PUMP 20 A 1 0.5 kVA 0.4 kVA 3 20 A BP-1 16

13 -- PUMP 20 A 1 0.5 kVA 0.0 kVA 1 20 A Spare -- 14

11 -- PUMP 20 A 1 0.5 kVA 0.0 kVA 1 20 A Spare -- 12

9 -- RECPTS 11TH FLR (EXISTING) 20 A 1 1.1 kVA 0.0 kVA 1 40 A SPARE RADIO REP. (EXISTING) -- 10

7 -- RECPTS 11TH FLR (EXISTING) 20 A 1 1.1 kVA 1.1 kVA 1 20 A RECPTS C7121 (EXISTING) -- 8

5 -- ROTATING (ROOF) (EXISTING) 20 A 1 0.5 kVA 1.1 kVA 1 20 A RECPTS C7121 (EXISTING) -- 6

3 Spare RECPT FOR RCP-1 20 A 1 0.2 kVA 1.1 kVA 1 20 A RECPTS C7121 (EXISTING) -- 4

1 -- Spare 20 A 1 0.0 kVA 0.2 kVA 1 20 A PAR MACY ALARM C7138 (EXISTING) -- 2

CKT*

Demolished Circuit Description Circuit Description Trip Poles A B C Poles Trip Circuit Description*

Demolished Circuit Description CKT

Notes: FEED THRU LUGS

Enclosure: Type 1

Mounting: Surface Wires: 4 Mains: 150 A

Supply From: Phases: 3 Mains Type: MCB

Location: ELECTR C-7059 Volts: 120/208 Wye A.I.C. Rating: 10,000 A

New Branch Panel: C7LE4

Calculated Existing

1

DRAWING NOTES:0

1. REPLACE EXISTING PANEL. RECONNECT EXISTINGFEEDER AND LOADS AS SHOWN.

Notes:

Total Est. Demand Current: 30 A

Total Conn. Current: 30 A

Total Est. Demand: 24540 VA

Total Conn. Load: 24540 VA

Spare 24540 VA 100.00% 24540 VA

Load Classification Connected Load Demand Factor Estimated Demand Panel Totals

Legend:

Total Amps: 30 A 30 A 30 A

Total Load: 8180 VA 8180 VA 8180 VA

29 -- -- -- 0.4 kVA 0.0 kVA -- -- Space 30

27 -- -- -- 0.4 kVA 0.0 kVA -- -- Space 28

25 EF-37 20 A 3 0.4 kVA 0.0 kVA -- -- Space 26

23 -- -- -- 0.4 kVA 0.0 kVA -- -- Space 24

21 -- -- -- 0.4 kVA 0.0 kVA -- -- Space 22

19 EF-41 20 A 3 0.4 kVA 0.0 kVA -- -- Space 20

17 -- -- -- 0.0 kVA 0.0 kVA -- -- Space 18

15 -- -- -- 0.0 kVA 0.0 kVA -- -- Space 16

13 SPARE 20 A 3 0.0 kVA 0.0 kVA -- -- Space 14

11 -- -- -- 1.0 kVA 0.0 kVA -- -- Space 12

9 -- -- -- 1.0 kVA 0.0 kVA -- -- Space 10

7 NEW RF 20 A 3 1.0 kVA 0.0 kVA -- -- Space 8

5 -- -- -- 6.3 kVA 0.0 kVA -- -- Space 6

3 -- -- -- 6.3 kVA 0.0 kVA -- -- Space 4

1 NEW AHU-70 50 A 3 6.3 kVA 0.0 kVA -- -- Space 2

CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT

Notes: FEED THRU LUGS

Enclosure: Type 1

Mounting: Surface Wires: 3 Mains: 100 A

Supply From: C6HEX Phases: 3 Mains Type: MCB

Location: STAIR 2-7 Volts: 480 Delta A.I.C. Rating: 14,000 A

New Branch Panel: C7HEX

MOTOR LOAD, NEC ADJUSTED

10/05/18COVERING

ELECTRICAL DESIGN

10/05/18RESPONSIBLE

CHARGERevisions: Date:

AV SYMBOLS WITH ELECTRICAL REQUIREMENTS

WCSCLASSROOM SOUNDFIELD SYSTEM RECEIVER/AMPLIFIER/MIXER AND WALL OUTLET (44" MH UNLESS NOTEDOTHERWISE). TWO 1-GANG BOXES WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. SUBSCRIPT "W"INDICATES WALL MOUNTED ON SHELF. SOUNDFIELD SYSTEM, GROMMETED FACEPLATES AND CABLING PER DIV 27.

SH

SURFACE MOUNTED PAGING/INTERCOM SPEAKER (90" MH UNLESS NOTED OTHERWISE). SUBSCRIPT "H" INDICATESHANGING CEILING SPEAKER. 1-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. SPEAKER,INSTALLATION AND CABLING PER DIV 27.

MUSIC PLAY BACK SPEAKER (102" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. GROMMETED FACEPLATE, SPEAKER, INSTALLATION ADJACENT TO BOX AND WIRINGPER DIV 27.

SM

S HORN TYPE PAGING/INTERCOM SYSTEM SPEAKER (90" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUITTO ABOVE ACCESSIBLE CEILING PER DIV 26. GROMMETED FACEPLATE, SPEAKER, INSTALLATION AND WIRING PER DIV 27.

VPAGING/INTERCOM SYSTEM WALL MOUNTED SPEAKER VOLUME CONTROLLER (46" MH UNLESS NOTED OTHERWISE).1-GANG BOX AND 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. VOLUME CONTROLLER WITHFACEPLATE, INSTALLATION AND WIRING PER DIV 27.

M# X

MICROPHONE JACKPLATE (18" MH UNLESS NOTED OTHERWISE). "#"=NUMBER OF GANG, "X"=NUMBER OF JACKS IFOTHER THAN TWO (2). PROVIDE 0.75" CONDUIT FOR 1-GANG BOX OR 1" CONDUIT FOR 2-GANG AND LARGER BOX TOABOVE ACCESSIBLE CEILING PER DIV 26. JACKS, FACEPLATE AND CABLING PER DIV 27.

WC XWALL MOUNTED AV SYSTEM CONTROL INTERFACE. SUBSCRIPT "X" INDICATES TYPE. REFER TO SYSTEM DIAGRAMS.BACKBOX (46" MH UNLESS NOTED OTHERWISE) WITH 1" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26.CONTROLLER WITH CABLING PER DIV 27.

SR X LOCAL SOUND REINFORCEMENT SYSTEM SPEAKER. SUBSCRIPT "X" INDICATES TYPE. REFER TO SYSTEM DIAGRAMS.

SJ SPEAKER JACKPLATE (18" MH UNLESS NOTED OTHERWISE). 3-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLECEILING PER DIV 26.

WSF WALL MOUNTED SOUNDFIELD SYSTEM SPEAKER. 1-GANG BOX WITH 1" CONDUIT TO ABOVE CEILING PER DIV 26.SPEAKER AND CABLING PER DIV 27.

PRX

WALL MOUNTED PROJECTOR. BACKBOX WITH 1-1.25" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. PROJECTOR,MOUNT AND CABLING PER DIV 27. SUBSCRIPT "X" INDICATES CONFIGURATION TYPE, REFER TO FACEPLATE DETAILS.

WALL MOUNT ELECTRIC PROJECTION SCREEN. 1-GANG BOX WITH 1" CONDUIT TO ABOVE ACCESSIBLE CEILING PERDIV 26. SCREEN AND LOW VOLTAGE CONTROL PER DIV 27.PS E

CEILING MOUNT ELECTRIC PROJECTION SCREEN. 1-GANG BOX WITH 1" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV26. SCREEN AND LOW VOLTAGE CONTROL PER DIV 27.PS

E

LOCAL SOUND SYSTEM SENSING MICROPHONE. 1-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PERDIV 26. MICROPHONE WITH GROMMETED FACEPLATE, INSTALLATION AND WIRING PER DIV 27.SM

HM (x)HANGING MICROPHONE OUTLET. 1-GANG BOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. SUBSCRIPT"X" INDICATES QUANTITY OF MICROPHONES IF MORE THAN ONE (1). MICROPHONE, JACK, FACEPLATE AND WIRING PER DIV 27.

MA MIC/AUX WALL MOUNTED INPUT (18" MH UNLESS NOTED OTHERWISE). 2-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. JACKS, FACEPLATE AND CABLING PER DIV 27.

MS MICROPHONE/SPEAKER WALL MOUNTED JACKPLATE (18" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75"CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. JACKS, FACEPLATE AND CABLING PER DIV 27.

ME MONITOR/EFFECTS WALL OUTLET (18" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. JACKS, FACEPLATE AND WIRING PER DIV 27.MULTI-PIN CONNECTOR WALL OUTLET (18" MH UNLESS NOTED OTHERWISE). NEMA BOX FOR 8"x8" PLATE WITH 2" CONDUITTO ABOVE ACCESSIBLE CEILING PER DIV 26. 8"x8" PLATE WITH CONNECTORS AND WIRING PER DIV 27.MP

REMOTE POWER SWITCH OUTLET (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. SWITCH, FACEPLATE AND WIRING PER DIV 27.

R

P PROGRAM SOURCE CABINET FOR PAGING/INTERCOM SYSTEM. TWO 1-GANG BOXES WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. GROMMETED FACEPLATES, CABINET, INSTALLATION AND WIRING PER DIV 27.

CAWALL MOUNTED CALL ANNUNCIATOR FOR PAGING/INTERCOM SYSTEM (90" MH UNLESS NOTED OTHERWISE). CUSTOMBACKBOX FURNISHED PER DIV 27, INSTALLED WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26.ANNUNCIATOR, INSTALLATION AND WIRING PER DIV 27.

CO WALL MOUNTED CALL ORIGINATION SWITCH FOR PAGING/INTERCOM SYSTEM (46" MH UNLESS NOTED OTHERWISE). 1-GANGBOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. CALL SWITCH, FACEPLATE AND WIRING PER DIV 27.

15W

SINGLE FACED WALL MOUNTED CLOCK (102” MH UNLESS NOTED OTHERWISE). 12” DIAMETER FACE ANALOG CLOCKUNLESS SUBSCRIPT “15” FOR 15” DIAMETER FACE ANALOG CLOCK OR “LED” FOR LED DIGITAL CLOCK. SUBSCRIPT “W”INDICATES WIREGUARD. 1-GANG BOX WITH 0.75” CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26.

15 DOUBLE FACED WALL MOUNTED CLOCK (102” MH UNLESS NOTED OTHERWISE). 12” DIAMETER FACE ANALOG CLOCKUNLESS SUBSCRIPT “15” FOR 15” DIAMETER FACE ANALOG CLOCK OR “LED” FOR LED DIGITAL CLOCK. 1-GANG BOX WITH0.75” CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26.ROOF MOUNTED ANTENNA. REFER TO ANTENNA MOUNTING DETAIL FOR MORE INFORMATION. SUBSCRIPT INDICATESTYPE.A

X

TECHNOLOGY SYMBOLS WITH ELEC. REQUIREMENTS

PWALL MOUNTED PHONE OUTLET (46" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT TO ABOVE ACCESSIBLECEILING PER DIV 26. JACKS, FACEPLATE AND CABLE PER DIV 27. REFER TO FACEPLATE DETAILS.

XR WALL MOUNTED AV OUTLET (84" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT PER DIV 26. REFER TO FACEPLATEDETAILS. JACKS, FACEPLATE AND CABLING PER DIV 27. SUBSCRIPT "X" INDICATES ALTERNATE CONFIGURATION.

XV WALL MOUNTED AV OUTLET (44" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT PER DIV 26. REFER TO FACEPLATEDETAILS. JACKS, FACEPLATE AND CABLING PER DIV 27. SUBSCRIPT "X" INDICATES ALTERNATE CONFIGURATION.

CONDUIT SLEEVE / FIRE RATED SLEEVE ASSEMBLY THRU WALL (1-2" SLEEVE UNLESS NOTED OTHERWISE) PER DIV 26.

J TELECOM BOX AND CONDUIT PER DIV 26, REFER TO PLANS.

D WALL MOUNTED VOICE/DATA OUTLET (18" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT(S) TO ABOVE CORRIDORCEILING PER DIV 26. JACKS, FACEPLATE AND CABLE PER DIV 27. REFER TO FACEPLATE DETAILS.

XIWALL MOUNTED AV OUTLET (18" MH UNLESS NOTED OTHERWISE). BOX WITH CONDUITS TO ABOVE ACCESSIBLECEILING PER DIV 26. REFER TO FACEPLATE DETAILS. JACKS, FACEPLATE AND CABLING PER DIV 27. SUBSCRIPT "X"INDICATES ALTERNATE CONFIGURATION.

APWALL MOUNTED WIRELESS ACCESS POINT (96” MH UNLESS NOTED OTHERWISE). BOX WITH CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. WAP AND CABLE PER DIV 27.

POKE-THRU PER DIV 26. # INDICATES TYPE, REFER TO POKE-THRU (PT) SCHEDULE. SUBSCRIPT "X" INDICATESTECHNOLOGY DEVICE(S), REFER TO TECHNOLOGY DETAILS.

#X

FLOOR BOX PER DIV 26. # INDICATES TYPE, REFER TO FLOOR BOX (FB) SCHEDULE. SUBSCRIPT "X" INDICATESTECHNOLOGY DEVICE(S), REFER TO TECHNOLOGY DETAILS.

#X

CUSTOM OUTLET IN SURFACE RACEWAY. SURFACE RACEWAY PER DIV 26. OUTLET JACKS, FACEPLATE AND CABLINGPER DIV 27.W

SECURITY SYMBOLS WITH ELECTRICAL REQUIREMENTS

CC 1 CCTV SYSTEM WALL MOUNTED CAMERA (REFER TO CAMERA SCHEDULE FOR MOUNTING HEIGHT AND CAMERASPECIFICATIONS). SUBSCRIPT "X" INDICATES ENTRY IN CAMERA SCHEDULE. 1-GANG BOX WITH 0.75" CONDUIT TOABOVE ACCESSIBLE CEILING PER DIV 26. CAMERA AND CABLING PER DIV 28.

PS1 LOCAL LOW VOLTAGE POWER SUPPLY FOR EXTERIOR CAMERA. SUBSCRIPT "X" INDICATES ASSOCIATED CAMERA.

120V POWER INTO LOCAL JUNCTION BOX ABOVE CEILING AND CONNECTION TO POWER SUPPLY PER DIV 26.POWER SUPPLY MOUNTED ABOVE CEILING AND LOW VOLTAGE WIRING TO LOCAL CAMERA PER DIV 28.

ICWALL MOUNTED INTERCOM DOOR STATION (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TOABOVE ACCESSIBLE CEILING PER DIV 26. INTERCOM AND CABLING PER DIV 28.

DMDOOR POSITION SWITCH WITH WIRING PER DIV 28. CONDUIT PATHWAYS FROM DOOR FRAME TO COMMON SMSJUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. PROVIDE ONE CONTACT FOR EACH LEAF IN MULTI-DOOROPENINGS. REFER TO SECURITY ROUGH-IN DETAILS.

ELELECTRONIC DOOR LOCK AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING PER DIV 28. CONDUIT PATHWAYSFROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. REFER TO SECURITYROUGH-IN DETAILS.

EMELECTRONIC MAG LOCK AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING PER DIV 28. CONDUIT PATHWAYSFROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. REFER TO SECURITYROUGH-IN DETAILS.

ESELECTRONIC STRIKE AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING PER DIV 28. CONDUIT PATHWAYS FROMDOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. REFER TO SECURITY ROUGH-IN DETAILS.

LB

RXREQUEST TO EXIT SWITCH IN DOOR HARDWARE BY OTHERS. LOW VOLTAGE WIRING PER DIV 28. CONDUIT PATHWAYSFROM DOOR FRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. REFER TO SECURITYROUGH-IN DETAILS.

HDHANDICAP DOOR OPERATOR MOTOR ASSEMBLY BY OTHERS. 120V POWER CONNECTION AND CONDUIT FROM DOORFRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. LOW VOLTAGE WIRING ANDINTERFACE WITH SMS AND DOOR ACTUATOR BUTTONS PER DIV 28. REFER TO SECURITY ROUGH-IN DETAILS.

HA

WALL/PEDESTAL MOUNT HANDICAP DOOR ACTUATOR BUTTON, FURNISHED BY OTHERS. BOX AS REQUIRED BYSYSTEM MANUFACTURER WITH INSTALLATION AND CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLECEILING PER DIV 26. ALL LOW VOLTAGE WIRING AND INTERFACE WITH SMS AND DOOR MOTOR PER DIV 28. REFERTO SECURITY ROUGH-IN DETAILS.

HOFA

WALL/FLOOR MOUNTED ELECTROMAGNETIC DOOR HOLD OPEN WITH POWER SUPPLY INSTALLED BY OTHERS. 120VPOWER AND CONNECTION, BOX AS REQUIRED BY MANUFACTURER AND CONDUIT TO COMMON SMS JUNCTION BOX ABOVEACCESSIBLE CEILING PER DIV 26. LOW VOLTAGE WIRING FROM POWER SUPPLY TO HOLD OPEN AND INTERFACE WITHSMS PER DIV 28. SUBSCRIPT "FA" INDICATES DEVICES POWERED FROM FIRE ALARM SYSTEM AND INTERFACE FROM SMSTO FIRE ALARM SYSTEM REQUIRED FOR DOOR RELEASE PER DIV 28. REFER TO SECURITY ROUGH-IN DETAILS.

CRWALL MOUNTED PROXIMITY CARD READER (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH CONDUIT TOCOMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. CARD READER AND CABLING PER DIV 28.REFER TO SECURITY ROUGH-IN DETAILS.

CR EL

ELEVATOR CAB MOUNTED CARD READER. READER TO BE INSTALLED IN ELEVATOR CAB AS COORDINATED WITHELEVATOR CONTRACTOR. WIRING FROM CAB THRU TRAVELING CABLE TO ELEVATOR CONTROLLER IN ELEVATORMACHINE ROOM AND INTERFACE WITH ELEVATOR CONTROLLER AND SMS PER DIV 28, COORDINATE WITH ELEVATORCONTRACTOR. REFER TO SECURITY ROUGH-IN DETAILS.

KCWALL MOUNTED COMBINATION KEYPAD/CARDREADER (46" MH UNLESS NOTED OTHERWISE). 2-GANG BOX WITH 0.75"CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. DEVICE AND CABLING PER DIV 28.

KWALL MOUNTED SECURITY KEYPAD ENTRY STATION (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75"CONDUIT TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. KEYPAD AND CABLING PER DIV 28.

MD WALL MOUNTED MOTION DETECTOR (90" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TO ABOVEACCESSIBLE CEILING PER DIV 26. MOTION DETECTOR, WALL MOUNT HARDWARE, AND CABLING PER DIV 28.

PP WWALL MOUNTED PANIC/DURESS BUTTON (46" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 0.75" CONDUIT TOABOVE ACCESSIBLE CEILING PER DIV 26. BUTTON AND CABLING PER DIV 28.

XWALL MOUNTED SECURITY SYSTEM WIRING OUTLET MOUNTED BELOW COUNTER TOP. 2-GANG BOX WITH 2-1"CONDUITS TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. GROMMETED FACEPLATE ANDSECURITY SYSTEM CABLING PER DIV 28.

CMWALL MOUNTED MONITOR OUTLET FOR CCTV SYSTEM (84" MH UNLESS NOTED OTHERWISE). 1-GANG BOX WITH 1"CONDUIT TO ABOVE CORRIDOR CEILING PER DIV 26. JACK, FACEPLATE AND CABLING PER DIV 28.

MIC CEILING MOUNTED SECURITY/CCTV SYSTEM AUDIO MICROPHONE. 1-GANG BOX MOUNTED IN CEILING PER DIV 26.MICROPHONE AND CABLING PER DIV 28.

BRWALL MOUNTED BIOMETRIC READER (46" MH UNLESS NOTED OTHERWISE). 2-GANG BOX WITH 0.75" CONDUIT TOCOMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING PER DIV 26. READER AND CABLING PER DIV 28. REFERTO SECURITY ROUGH-IN DETAILS.

X

X

MD

PB WWALL MOUNTED PUSH BUTTON FOR LOCAL ELECTRONIC DOOR RELEASE (46" MH UNLESS NOTED OTHERWISE). 1-GANGBOX WITH 0.75" CONDUIT TO ABOVE ACCESSIBLE CEILING PER DIV 26. BUTTON AND CABLING PER DIV 28.

ELECTRONIC LATCH BOLT MONITORING. HARDWARE AND INSTALLATION BY OTHERS. LOW VOLTAGE WIRING PER DIV28. CONDUIT PATHWAYS FROM DOOR FRAME TO COMMON SECURITY JUNCTION BOX ABOVE CEILING PER DIV 26.REFER TO SECURITY ROUGH-IN DETAILS.CEILING MOUNTED MOTION DETECTOR. 1-GANG BOX MOUNTED IN CEILING PER DIV 26. DETECTOR AND CABLINGPER DIV 28.

DC

LOCAL IP BASED 2-DOOR ACCESS CONTROL PANEL SERVING LOCAL CARD READER/SECURITY CONTROLLED DOORS.LOCATE ABOVE ADJACENT ACCESSIBLE CEILING. PROVIDE DATA DROP IN 0.75" CONDUIT TO LOCAL DATA CLOSET.EXTEND 1" CONDUIT WITH DOOR SECURITY WIRING TO LOCAL SECURITY SYSTEM JUNCTION BOX. REFER TO SECURITYROUGH-IN DETAILS.

JB

SECURITY SYSTEM JUNCTION BOX TO BE LOCATED ABOVE ACCESSIBLE CEILING (MIN 6"X6"X4"). ROUTE LOCAL DOORSECURITY WIRING CONDUITS/RACEWAYS TO JUNCTION BOX. EXTEND 1" CONDUIT WITH DOOR SECURITY WIRING TOLOCAL 2-DOOR CONTROL PANEL/REMOTE DOOR CONTROL PANEL AS INDICATED ON DRAWINGS. REFER TO SECURITYROUGH-IN DETAILS.

PL

SITE POLE FOR MOUNTING SECURITY CAMERAS (REFER TO SPECIFICATIONS FOR SIZE/TYPE). PROVIDE POLE WITHCONCRETE BASE AS INDICATED ON PLANS. EXTEND AND CONNECT TO SITE CONDUIT SYSTEM AS INDICATED ONPLANS. PROVIDE NEMA 3R JUNCTION BOX AT BASE OF POLE FOR CAMERA EQUIPMENT (120V POWER SUPPLY, FIBERCONVERTERS, ETC.). REFER TO SECURITY ROUGH-IN DETAILS.

ABBREVIATIONSAAP - AREA ALARM PANEL - MEDICAL GASACC - ACCESSADJ - ADJUSTABLEAF - ARC FAULT CIRCUIT INTERRUPTERAFCI - ARC FAULT CIRCUIT INTERRUPTERAFF - ABOVE FINISHED FLOOR TO BOTTOM OF ITEMAFG - ABOVE FINISHED GRADE TO BOTTOM OF ITEMALT - ALTERNATEAP - ACCESS PANELAPPROX - APPROXIMATEARCH - ARCHITECT OR ARCHITECTURALASSY - ASSEMBLYATS - AUTOMATIC TRANSFER SWITCH

BLDG - BUILDINGBOE - BOTTOM OF EQUIPMENTBOT - BOTTOMBTWN - BETWEEN

CFCI - CONTRACTOR FURNISHED CONTRACTOR INSTALLEDCKT - CIRCUITCLG - CEILINGCMU - CONCRETE MASONRY UNITCONN - CONNECT OR CONNECTIONCONTR - CONTRACTORCOR - CONTRACTING OFFICER'S REPRESENTATIVECORR - CORRIDORCTR - CENTER

D - DEPTHDET - DETAILDIA - DIAMETERDIM - DIMENSIONDIV - DIVISIONDN - DOWNDWG - DRAWING

EA - EACHEC - ELECTRICAL CONTRACTOR (DIVISION 26)EJ - EXPANSION JOINTELEC - ELECTRICALELEV - ELEVATION OR ELEVATOREM - EMERGENCYEQ - EQUALEQS - EQUIPMENT SUPPLIEREQUIP - EQUIPMENTETR - EXISTING TO REMAINEX - EXISTINGEXP - EXPANSIONEXT - EXTERIOR

FCE - FIRE CONTROL EQUIPMENTFF - FINISHED FLOOR ELEVATIONFLR - FLOORFSC - FIRE SUPPRESSION CONTRACTOR (DIVISION 21)FT - FEETFTG - FOOTING

GC - GENERAL CONTRACTORGF - GROUND FAULT CIRCUIT INTERRUPTERGFCI - GROUND FAULT CIRCUIT INTERRUPTER OR GOVERNMENT

FURNISHED CONTRACTOR INSTALLEDGFFT - GROUND FAULT FEED THRU

HC - HVAC CONTRACTOR (DIVISION 23)HP - HORSE POWER OR HIGH POINTHVAC - HEATING, VENTILATING, AND AIR CONDITIONING

ID - INSIDE DIAMETERIN - INCHES

KEC - KITCHEN EQUIPMENT CONTRACTOR

L - LENGTHLBS - POUNDS

MAP - MASTER ALARM PANEL (MEDICAL GAS)MAX - MAXIMUMMEZZ - MEZZANINEMFR - MANUFACTURERMH - MANHOLE OR MOUNTING HEIGHT TO CENTER LINE OF ITEMMIN - MINIMUM OR MINUTEMISC - MISCELLANEOUSMTD - MOUNTEDMTG - MOUNTING

NIC - NOT IN CONTRACTNOM - NOMINALNTS - NOT TO SCALE

OD - OUTSIDE DIAMETEROFCI - OWNER FURNISHED CONTRACTOR INSTALLEDOFOI - OWNER FURNISHED OWNER INSTALLED

PC - PLUMBING CONTRACTOR (DIVISION 22)PLBG - PLUMBING

RAD - RADIUSREC - RECESSEDREQD - REQUIREDRI - ROUGH-IN

S - SURFACE MOUNTEDSC - SECURITY CONTRACTORSCH - SCHEDULESHT - SHEETSMS - SECURITY MANAGEMENT SYSTEMSPEC - SPECIFICATIONSSQ - SQUARESS - STAINLESS STEELSTD - STANDARDSTRUC - STRUCTURAL OR STRUCTURESUC - SITE UTILITY CONTRACTOR

TC - TECHNOLOGY CONTRACTORTEMP - TEMPERATURETOE - TOP OF EQUIPMENTTYP - TYPICAL

UNO - UNLESS NOTED OTHERWISE

VFD - VARIABLE FREQUENCY DRIVEVOL - VOLUME

W/ - WITHW/0 - WITHOUTWP - WEATHERPROOF

ZVC - ZONE VALVE CABINET

3

3

1

E2

B

E2DETAIL: B = DETAIL DESIGNATION

E2 = SHEET WHERE DETAIL IS LOCATED

SECTION: 1 = SECTION DESIGNATION E2 = SHEET WHERE DETAIL IS LOCATED

PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH IT IS SHOWN.

DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.

GENERAL FLOOR PLAN NOTES

WIRE & CONDUIT IN WALL OR ABOVE CEILING.

WIRE & CONDUIT IN OR BELOW SLAB OR GRADE.

CABLE TRAY, 12" x 4" DEEP UNLESS NOTED OTHERWISE.

CONDUIT FOR DATA CIRCUITRY.DAT

WIRE & CONDUIT FOR FIRE ALARM CIRCUITRY.FA

WIRE & CONDUIT FOR NURSE CALL CIRCUITRY.NC

EXISTING WIRE & CONDUIT TO REMAIN.E

CONDUIT TO BE REMOVED.

WIRE & CONDUIT FOR NIGHT LIGHT CIRCUITRY.NL

CONDUIT FOR PHONE CIRCUITRY.PHO

WIRE & CONDUIT FOR SECURITY SYSTEM CIRCUITRY.SEC

WIRE RUN IN SURFACE WIREWAY.W

CABLE MANAGEMENT SYSTEM PATHWAY.CM

WIRE & CONDUIT FOR EMERGENCY CIRCUITRY.EM

WIRE & CONDUIT FOR SOUND SYSTEM CIRCUITRY.S

WIRE & CONDUIT FOR INTERCOM SYSTEM CIRCUITRY.I

WIRE & CONDUIT FOR TELEVISION SYSTEM CIRCUITRY.TV

FIRE ALARM SYMBOLS

FIRE ALARM BELL & SIGNAL LIGHT (80" AFF). # WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOTSHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS.

FIRE ALARM CHIME & SIGNAL LIGHT (80" AFF). # WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOTSHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS.

FIRE ALARM HORN & SIGNAL LIGHT (80" AFF). # WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOTSHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS.

FIRE ALARM SIGNAL LIGHT (80" AFF). # WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN,THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS.

15F

15F

15F

15

F

SF

CEILING MOUNTED FIRE ALARM SPEAKER.

CEILING MOUNTED FIRE ALARM SPEAKER & SIGNAL LIGHT. # WHEN SHOWN INDICATES CANDELA RATING OF STROBE.WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHERLOCATIONS.

FIRE ALARM MANUAL STATION (46" MH UNLESS NOTED OTHERWISE). SUBSCRIPT "K" INDICATES KEY OPERATED.

CEILING MOUNTED SMOKE DETECTOR.

CEILING MOUNTED HEAT DETECTOR.

DUCT MOUNTED SMOKE DETECTOR. SUBSCRIPT "S" INDICATES SUPPLY. SUBSCRIPT "R" INDICATES RETURN.

DUCT MOUNTED HEAT DETECTOR. SUBSCRIPT "S" INDICATES SUPPLY. SUBSCRIPT "R" INDICATES RETURN.

ELECTRIC RELEASE DOOR CLOSER.

ELECTRO-MAGNETIC DOOR HOLDER.

WATER FLOW SWITCH.

VALVE SUPERVISORY SWITCH.

CEILING MOUNTED REMOTE TEST STATION AND ALARM INDICATOR LIGHT FOR DUCT DETECTOR. SUBSCRIPT "W" INDICATESWALL MOUNTED.

SMOKE DAMPER.

FIRE FIGHTER'S TELEPHONE (60" MH UNLESS NOTED OTHERWISE).

KF

S

H

C

D

FS

V

RW

SD

FT

PRESSURE SWITCH.

ADDRESSABLE MODULE. SUBSCRIPT "I" INDICATES INPUT. SUBSCRIPT "C" INDICATES CONTROL.

POST INDICATOR VALVE.

KNOX BOX (46" MH UNLESS NOTED OTHERWISE). SUBSCRIPT "S" INDICATES SUPERVISED UNIT.

PS

AMC/I

PIV

KS

H

SS/R

S/R

S 15F

FIRE ALARM BELL (80" AFF UNLESS NOTED OTHERWISE). SUBSCRIPT "W" INDICATES EXTERIOR WEATHERPROOF UNIT.FW

BEAM DETECTOR. SUBSCRIPT "T" INDICATES TRANSMITTER FUNCTION. SUBSCRIPT "R" INDICATES RECEIVER FUNCTION.BT/R

AIR SAMPLING SMOKE DETECTOR SAMPLING PORT.A

COMBINATION FIRE ALARM AND MASS NOTIFICATION CONTROL PANEL.FMCP

FIRE ALARM AND MASS NOTIFICATION COMBINATION SPEAKER & SIGNAL LIGHT (80" AFF). # WHEN SHOWN INDICATESCANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 75CANDELA FOR ALL OTHER LOCATIONS. DEVICE SHALL HAVE RED BODY MARKED "ALERT" IN WHITE LETTERING WITH CLEARLENS.

15F

LOCAL OPERATOR'S CONSOLE.LOC

AUDIO CONTROL UNIT.ACU

15

F

CEILING MOUNTED FIRE ALARM AND MASS NOTIFICATION COMBINATION SPEAKER & SIGNAL LIGHT. # WHEN SHOWNINDICATES CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA INCORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS. DEVICE SHALL HAVE RED BODY MARKED "ALERT" INWHITE LETTERING AND HAVE CLEAR LENS.

S 15F

FIRE ALARM AND MASS NOTIFICATION SIGNAL LIGHT (80" AFF). # WHEN SHOWN INDICATES CANDELA RATING OF STROBE.WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 75 CANDELA FOR ALL OTHERLOCATIONS. DEVICE SHALL HAVE RED BODY MARKED "ALERT" IN WHITE LETTERING WITH CLEAR LENS.

SURFACE MOUNTED FIRE ALARM SPEAKER (80" AFF). SUBSCRIPT "R" INDICATES RECESSED MOUNTING.SR

AV SYMBOLS

42 FLAT PANEL DISPLAY WITH WALL MOUNTING HARDWARE (84" MH UNLESS NOTED OTHERWISE). # INDICATES NOMINALSCREEN DIAGONAL SIZE.

AV AV SYSTEM CONTROLLER.

DV W BLU-RAY/DVD PLAYER WITH CONNECTION TO LOCAL OUTLET. SUBSCRIPT "W" INDICATES WALL MOUNTED ON SHELF.

SBW

VIDEO ON DEMAND SET TOP BOX. SUBSCRIPT "W" INDICATES WALL MOUNTED ON SHELF.

PC LOCAL RS-232/IP PROJECTOR CONTROLLER.

PS WALL MOUNTED MANUAL PROJECTION SCREEN.

PS CEILING MOUNTED MANUAL PROJECTION SCREEN.

SF SOUNDFIELD SYSTEM CEILING SPEAKER.

IR SOUNDFIELD SYSTEM CEILING IR SENSOR. LOCATION SHOWN FOR ESTIMATING PURPOSES ONLY. EACH SYMBOLREPRESENTS A QUANTITY OF TWO (2) SENSORS TO BE LOCATED FOR OPTIMUM DROP-FREE RECEPTION.

SC CEILING MOUNTED PAGING/INTERCOM SYSTEM SPEAKER.

15W

SINGLE FACED, WALL MOUNTED CLOCK (102" MH UNLESS NOTED OTHERWISE). 12" DIAMETER FACE UNLESSSUBSCRIPT "15" FOR 15" DIAMETER FACE. SUBSCRIPT "W" INDICATES WIREGUARD.

15 DOUBLE FACED, WALL MOUNTED CLOCK (102" MH UNLESS NOTED OTHERWISE). 12" DIAMETER FACE UNLESSSUBSCRIPT "15" FOR 15" DIAMETER FACE.

INTERACTIVE WHITE BOARD.IW

PRX

CEILING MOUNTED PROJECTOR. SUBSCRIPT "X" INDICATES CONFIGURATION TYPE, REFER TO FACEPLATE DETAILS.

AR AREA OF REFUGE / AREA OF RESCUE REMOTE CALL STATION (46" MH UNLESS NOTED OTHERWISE).

AP AREA OF REFUGE / AREA OF RESCUE POWER SUPPLY WITHIN A WALL MOUNTED ENCLOSURE.

AM W

AE AREA OF REFUGE / AREA OF RESCUE EXPANSION SWITCH WITHIN A WALL MOUNTED ENCLSURE.

AREA OF REFUGE / AREA OF RESCUE MAIN CONTROL PANEL. "W" INDICATES WALL MOUNTED WITHIN AN ENCLOSURE,OTHERWISE DESKTOP UNIT.

NURSE CALL SYMBOLS

NURSE CALL DESK MOUNTED MASTER CONTROL STATION (OUTLET AT 18" MH UNLESS NOTED OTHERWISE). SUBSCRIPT"W" INDICATES WALL MOUNT (46" MH UNLESS NOTED OTHERWISE). RAULAND RESPONDER MODEL #351205

NURSE CALL CONTROL PANEL.

NURSE CALL STAFF STATION (46" MH UNLESS NOTED OTHERWISE).

NURSE CALL DUTY STATION (46" MH UNLESS NOTED OTHERWISE). RAULAND RESPONDER MODEL # 353100

EMERGENCY NURSE CALL STATION WITH PULL CORD FOR PATIENT USE (46” MH AND TO SIDE AND WITHIN 12” FROMFRONT OF TOILET BOWL IN TOILET ROOMS, 66” MH IN SHOWERS AND WET AREAS, 46” MH UNLESS NOTED OTHERWISE INALL OTHER AREAS).

PATIENT NURSE CALL UTILITY CONSOLE (46" MH UNLESS NOTED OTHERWISE).

PATIENT NURSE CALL STATION (ONE OR TWO CORDS AS INDICATED, 46" MH UNLESS NOTED OTHERWISE).RAULAND RESPONDER #354001

CEILING MOUNTED NURSE CALL DOME LIGHT.

WALL MOUNTED NURSE CALL DOME LIGHT (90" MH UNLESS NOTED OTHERWISE). RAULAND RESPONDER MODEL #352010

CEILING MOUNTED COMBINATION DOME LIGHT AND BUZZER.

CEILING MOUNTED NURSE CALL ZONE LIGHT.

NURSE CALL EMERGENCY BUTTON (46" MH UNLESS NOTED OTHERWISE).

EMERGENCY CODE BLUE BUTTON (46" MH UNLESS NOTED OTHERWISE).

N

N

NB

NZ

NC

NS

ND

N

WNM

NT

NE

NB

NCCP

NURSE CALL MULTI-PIN CATV JACK (84" AFF UNLESS NOTED OTHERWISE).

NURSE CALL STAFF PRESENCE STATION (60" AFF UNLESS NOTED OTHERWISE).

CNS

PNS

NOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT TO MODIFICATIONS ON OTHER DRAWINGS.

ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT NECESSARILY BE USED ON THIS

PROJECT.

GENERAL NOTESA. ALL FINAL LOCATIONS AND ARRANGEMENTS OF LIGHTING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL

REFLECTED CEILING PLAN.

B. LIGHTING FIXTURES WITH MORE THAN TWO LAMPS SHALL HAVE TWO OUTER LAMPS CONTROLLED WITH ONE SWITCHAND INNER LAMP(S) CONTROLLED BY A SECOND SWITCH.

C. EACH BRANCH CIRCUIT HOMERUN SHALL HAVE NO MORE THAN THREE CIRCUITS. EACH BRANCH CIRCUIT HOMERUN SHALLHAVE A SEPARATE GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR.

D. MULTI-GANG BACKBOXES FOR DIFFERENT VOLTAGES AND TYPES OF EMERGENCY AND NORMAL BRANCH WIRINGDEVICES SHALL HAVE DIVIDERS BETWEEN DEVICES.

GENERAL NOTES - DEMOLITIONA. FOR EXISTING EQUIPMENT, SUCH AS LIGHTING FIXTURES, WIRING DEVICES, CONDUITS, ETC., SHOWN ON PLANS

TO BE REMOVED, COMPLETELY CUT/CAP CONDUITS AT THE AREA OF WORK PERIMETER AND REMOVE CONDUITWITHIN THE WORK AREA, DISCONNECT WIRING AT THE OVERCURRENT PROTECTIVE DEVICE AND REMOVE WIRINGCOMPLETELY FROM THE ABANDONED CONDUITS.

B. DISCONNECT ALL ABANDONED WIRING OF ALL TYPES AT THE OVERCURRENT PROTECTIVE DEVICE. COMPLETELYREMOVE ALL ABANDONED WIRING.

C. MAINTAIN AND RESTORE, IF INTERRUPTED, ALL CONDUITS AND CONDUCTORS PASSING THROUGH RENOVATEDAREAS AND SERVICING UNDISTURBED AREAS.

EDCELECTRONIC DOOR LOCK, INSTALLATION AND WIRING BY OTHERS. PROVIDE CONDUIT PATHWAYS FROM DOORFRAME TO COMMON SMS JUNCTION BOX ABOVE ACCESSIBLE CEILING.

PROJECT NO.

10/05/18COVERINGTECHNOLOGY DESIGN

C:\B

IM\M

odel

\201

7-91

021-

Tec

hnol

ogy-

Cen

tral

_RLC

ondy

.rvt

10/5

/201

8 10

:49:

46 A

M

2017-91021

BID DOCUMENTS - OCTOBER 05, 2018

10/05/18RESPONSIBLE CHARGE

AP

D4D

DD5

DD3

DD3

AP

D4D

DD2 SC

D4 D D4 D

DD2

D2 D D2 D

DD2

P

V

F

APD2D

DD2

DD4

SC

AP

F

D4 D

F

F

SC

CC

CCF

CR

SC

AP CC SC

F

AP SC

DD4

DD4

DD4

AP

DD2

DD2

D4D

DD4

D4 D

APD

D4

D4 D

DD4

D4 D

DD4

D5D

SC

DD4

D4D

AP

D4 D

F

AP

DD4

AP

D4 D

D4D

D4 DAP

VF

D5D

DD5

D4D

D4 D

CR

CC

AP

AP

AP

D2DD2D

D2 D

D2D

D2 D

D2D

D2 D

D2D

D2D

DD2

DD2

DD2

DD2

DD2

D2 D

DD2

DD2

DD2

DD2

D2D

DD2

D4 D

ABANDONEDWALL MOUNTCABINET

1

1

1

1

2

3

3

3

2

3

3

4

3

3

2

33

RESEARCHPULMONARYC-6021

TOILETC-6023

RESEARCHPULMONARYC-6024

RESEARCHPULMONARYC-6025

RESEARCHPULMONARYC-6027

RESEARCHPULMONARYC-6028

RESEARCHPULMONARYC-6030

RESEARCHPULMONARYC-6032

RESEARCHPULMONARYC-6033

STORAGEC-6034

UNKNOWNC-6010

UNKNOWNC-6009

CHIEF SOCIALWORKERC-6008

ASSISTANTCHIEF SOCIALWORKERC-6007RESEARCH

PULMONARYC-6006

RESEARCHC-6004

TLT RMC-6005

UNKNOWNC-6011UNKNOWN

C-6012SPS CLEAN/PREPC-6013

SPS DECONC-6014

SPSCHANGINGC-6015

ENV.SERVICESC-6017

TOILETC-6016

STORAGEC-6020

SOILEDUTILITYC-6018MECH. RM

C-6019

MECH. ROOMC-6036

CORRIDORC6-23

RESEARCHPULMONARYC-6003

OFFICEC-6041

RESEARCHPULMONARYC-6002

RESEARCHPULMONARYC-6001

PULMONARYC-6162

RESEARCHPULMONARYC-6001

STAIRS1-6

SEIU LOCAL#551C-6058

SEIU LOCAL#551C-6059

SEIU LOCAL#551C-6060

SEIU LOCAL#551C-6061

TOILETC-6062

CORRIDORC6-22

MHICM OFFICEC-6110

FREIGHTELEVATORLOBBYC6-26

TEL. RM.85

TOILETC-6026

TOILETC-6029

TOILETC-6022

5

3

3

3

PROJECT NO.

10/05/18COVERINGTECHNOLOGY DESIGN

C:\B

IM\M

odel

\201

7-91

021-

Tec

hnol

ogy-

Cen

tral

_RLC

ondy

.rvt

10/5

/201

8 10

:49:

41 A

M

2017-91021

1/8" = 1'-0"TD-106

1 LEVEL 6 DEMOLITION PLAN

1. DISCONNECT EXISTING VIDEO SURVEILLANCE CAMERAS. PULL BACK DATA CABLE TOTHE NON-RENOVATION AREA NEAR THE SIGNALS CLOSET. RE-INSTALL DATA CABLEAFTER THE RENOVATION IS COMPLETED. SEE SHEET T2.16 FOR LOCATIONS.

2. GUEST WIRELESS ACCESS POINT (AP). REMOVE AND STORE IN A SECURE LOCATION.RE-INSTALL AS INDICATED ON SHEET TA-106 AND TA-107.

3. VA WIRELESS ACCESS POINT (AP). REMOVE AND STORE IN A SECURE LOCATION. RE-INSTALL AS INDICATED ON SHEET TA-106 AND TA-107.

4. DISCONNECT, REMOVE AND DISPOSE OF PROPERLY THE OLD NURSE CALL PANEL, THESCRAMBLE PAD PANEL AND THE MAGLOCK PANEL IN ROOM C6004.

5. EXISTING CARD READER TO REMAIN. PROVIDE PROTECTIVE COVER DURINGRENOVATIONS.

GENERAL DEMO NOTES:

BID DOCUMENTS - OCTOBER 05, 2018

10/05/18RESPONSIBLE CHARGE

AP

D5D

D5 D

DD5

DD5

D5D

AP

DD5

D5 D

D5 D

D5D AP

D5 D

D5 D

D5D

D4D

SC

F

CC

CR

AP

DD5

D2 D

CR

F

AP

AP

SC

D5D

D4 D

DD4

D5D

APD

D5

D5D

D4 D D4 D

DD5

DD5

APD

D5 DD5

DD5

P

D5D

D5 D

AP

AP

SCSC

APAP

SC

F

DD5

AP

SC

DD5

DD2

DD5

D5DD5D

D5 D

F

D5D

DD5

AP

DD5

AP

DD2

D4D

D2 D

AP

DD2

F

SC

DD5

AP

DD4

D5D

D5 D

D5D

AP

D5 D

DD5

SC

AP

CR

D5D

AP

D5 D

D5D

D5 D

F

CC

AP

DD5

DD5

F

AP

D5D

F

DD5

D4 D

CR

AP

AP

AP

D2 D

D5 D

P

D2 D

D5D

DD5

D5 D

DD5

D2 D

DD2

DD5

D2 DD2 DD2D

DD4

AP

AP

SC SC

AP

2

3

1

3

3

3

33 3

23

3

3

32

4

3

3

3

3

2

3 3

SECRETARYC-7033

STOR.C-7035

STAFFTOILETC-7039

STAFFTOILETC-7037

SUPERVISORYMEDICALSUPPORTASSISTANTC-7038

CHIEF PCSPROCEDURALC-7040

PROGRAMANALYSTC-7041

CHIEFMEDICALSERVICEC-7043

MEDICALSERVICEC-7042

CORRIDORC7-11

BUSINESSMANAGERC-7044

STORAGEC-7045

ASST. CHIEFMEDICALSERVICEC-7046

CHIEF PCSMEDICINE/ CMC-7047

CONFERENCEROOMC-7048

MECH RMC-7049

MAILROOM/BREAKROOMC-7051

STOR.C-7050

STAIRS2-7

FIRE EQUIP.C-7052

KITCHENC-7006

STAFF TOILETC-7005

STOR.C-7009

STOR.C-7007

PROGRAMSUPPORTASSISTANTSC-7008

STAFF TOILETC-7010

STOR.82

STOR.81

CHIEFHOSPITALISTC-7012

PIPE CHASEC-7011

STAFFTOILETC-7013

STAFFTOILETC-7015 CHIEF

GENERALINTERNALMEDICINEC-7016

STOR.C-7014

CHIEFGERIATRICSC-7018STAFF

TOILETC-7019

STAFFTOILETC-7023

STOR.C-7021

PIPE CHASEC-7020

PHYSICIANC-7022

PIPE CHASEC-7024

PHYSICIANC-7025

CORRIDORC7-10

CHIEFHEMATOLOGYC-7026

PIPE CHASEC-7027

CHIEFONCOLOGYC-7028

EMSC-7029

SOILEDUTILITYC-7030MECH. ROOM

C-7031

STOR.C-7032 STAFF

TOILETC-7034

CORRIDORC7-9

CONFERENCEROOMC-7179

CHIEFNEPHROLOGYC-7002

NEPHROLOGYC-7001

PHYSICIANC-7003

PHYSICIANC-7004

STAFFTOILETC-7056

CHIEFPULMONARYC-7057

CHIEF GIC-7058

CORRIDORC7-8

STAIRS1-7

FIRE EQUIP.C-7076 MECH. ROOM

C-7075

RESIDENTSC-7077

PHYSICIANC-7079

CORRIDORC7-7

TELE. ROOM48

PHARMACYSTORAGEC-7122

MED. SERV.ADIM.C-7123

PHARMACYSTORAGEC-7124

CLIN. DIETC-7138

FREIGHTELEVATORSLOBBYC7-12

VENDINGC-7139

3

3

3

5

C-9015CLOSET

C-9016CLOSET

C-9014

PROCESSING&

RECORDS

C-9013CLOSET

58CLOSET

57CLOSET

C-9010

HRSPECIALIZINGRECRUITMENT

&PLACEMENT

C-9027Room

C-9031CLOSET

C-9028

EMPLOYEE/LABORRELATIONS

C-9017

MEETINGROOM

C-9007BREAKROOM

C-9009STORAGE

C-9008STORAGE

C-9002

PERS.MANAG.

SPECIALIST

C-9005

PERS.MANAG.

SPECIALIST

C-9004

PERS.MANAG.

SPECIALIST

C-9003

PERS.MANAG.

SPECIALIST

C-9033Room

C-9037CLOSET

C-9038CLOSET

C-9032

MED.STAFF &NURSE

CREDENTIALING

C-9052

FIREEQUIPMENT

C-9051

ELEC.ROOM

C-9036

EMPLOYMENTINFORMATION

C9-3LOBBY

C-9050CLOSET

C-9039ENG.

C9-4LOBBY

C9-5CORRIDOR

C-9030

HRSPECIALIST

CLASSIFICATION

C-9035

HUMANRESOURCES

59

HUMANRESOURCES

C-9006

HUMANRESOURCES

6

6

7

6

PROJECT NO.

10/05/18COVERINGTECHNOLOGY DESIGN

C:\B

IM\M

odel

\201

7-91

021-

Tec

hnol

ogy-

Cen

tral

_RLC

ondy

.rvt

10/5

/201

8 10

:49:

46 A

M

2017-91021

1/8" = 1'-0"TD-107

1 LEVEL 7 DEMOLITION PLAN

GENERAL DEMO NOTES:1. DISCONNECT EXISTING VIDEO SURVEILLANCE CAMERAS. PULL BACK DATA CABLE TO THE

NON-RENOVATION AREA NEAR THE SIGNALS CLOSET. RE-INSTALL DATA CABLE AFTER THERENOVATION IS COMPLETED. SEE SHEET TA-107 FOR LOCATIONS.

2. GUEST WIRELESS ACCESS POINT (AP). REMOVE AND STORE IN A SECURE LOCATION. RE-INSTALL AS INDICATED ON SHEET TA-106 AND TA-107.

3. VA WIRELESS ACCESS POINT (AP). REMOVE AND STORE IN A SECURE LOCATION. RE-INSTALL AS INDICATED ON SHEET TA-106 AND TA-107.

4. REMOVE EXISTINGVIDEO SURVEILLANCE CAMERA AND TURN OVER TO THE OWNER. PULLBACK DATA CABLE TO THE NON RENOVATION AREA NEAR SIGNALS CLOSET. STORE CABLEAND LABEL FOR FUTURE USE.

5. EXISTING CARD READER TO REMAIN. PROVIDE PROTECTIVE COVER DURINGRENOVATIONS.

6. DISCONNECT EXISTING AP'S, SECURE AND STORE. COIL AND SECURE CURRENT DATACABLE TO KEEP FROM BEING DAMAGED DURING RENOVATION.

7. DISCONNECT EXISTING PAGING SPEAKERS, SECURE AND STORE. COIL AND SECURECURRENT WIRING TO KEEP FROM BEING DAMAGED DURING RENOVATION.

1/8" = 1'-0"TD-107

2 LEVEL 9 DEMOLITION PLAN - PARTIAL

BID DOCUMENTS - OCTOBER 05, 2018

10/05/18RESPONSIBLE CHARGE

SC

D

D

D

APG

D D

SC

DDD

D

D

DD

D

SC

APG

D

SC

SC

SC

D

SC SC

APG

DD

SC

D

D

D

D

D

D

SC

D

SC

APG

SC

V60" MH

IB

2

2

D

D

CR

CRCR

CR

CR

EDC1

CR

F

F

F

F

75F

F

F

F

F

F

F

F

F

F

D D D

EDC2

EDC4 EDC

5

EDC6

FF

F

F

F

F

F

F F F F

FF

F

FF

CC

D

DD

D

D

D D

D

D

D

DD D

D

DD

D

D D

D

D

D

D

D

D

D

D

D

D

DD

D

D

D

D

D

D

D

D

D

D

D

D

D

DD

D

D

D

D

D

D

D

D

D

D

DD

CC

CC

CC

D

D

APVA

APVA

APVA

APVA

APVA

AP

APVA

APVA

APVA

APVA

AP

V60" MH

1

APVA

EDC3

EDC7

EDC8

CR

CR

D

D

D

D

IA

V60" MH

IA

F

D

1

2

1

1

1

C-60563

C6-24-1CORRIDOR-1

S2-6STAIR

C6031

MECH.ROOM

C6032

MDOFFICE

C-6062

C-6060 C-6059 C-6058

C-6057

C-6055C-6056

C-6033

MECH.ROOM

C-6111

C-6110

C-6112

C6016-1

MDOFFICES-1

C6008-1PHYS-1

C6002

MDOFFICES

C6003CHIEF

C6007TLT RM

C6019MSA'S

C6030

MDOFFICE

C6024CHIEF

C6023

PRACTICEMNGR

C6021BUS MNGR

C6029PSA

C6006TLT RM

C6-22CORRIDOR

C6001LEARNERSC6-25

CORRIDOR

C6004BREAK RM

C6015

MDOFFICE

C6014PHYS

C6009LEARNERS

C6013LEARNERS

C6012RN

C6011CHIEF

C6010NP

C6005CONF RM

C6-24-2CORRIDOR-2

C6027N CHIEF

C6028MSA SUPV

C6025CHIEF

C6026-2N CHIEF-2

C6020VESTIBULE

C6022CONFERENCE

C6017

MDOFFICE

S1-6STAIR

601

139

6-25

631

6S2-6

7

6

4

5

6

6

6

MECH RMC6018

CORRIDOR-2C6-23-2

618

8

8

8

8

8

8

8

88

8

8

8

9

606

607

10

PROJECT NO.

10/05/18COVERINGTECHNOLOGY DESIGN

C:\B

IM\M

odel

\201

7-91

021-

Tec

hnol

ogy-

Cen

tral

_RLC

ondy

.rvt

10/5

/201

8 10

:49:

25 A

M

2017-91021

1/8" = 1'-0"TA-106

1 LEVEL 6 FLOOR PLAN

GENERAL PLAN NOTES:

1. GUEST WIRELESS ACCESS POINT LOCATION. PROVIDE ONE DATA.

2. COORDINATE DATA LOCATION WITH MECHANICAL CONTRACTOR.

3. EXISTING SIGNALS CLOSET. TERMINATE ALL NEW CABLING FROM THE 6TH FLOOR AT THIS LOCATION. REFER TO THE SPECIFICATIONS FOR DETAILS ON THE TERMINATION REQUIREMENTS.

4. BLACK ANALOG PHONE AND FAX LOCATION. CONFIRM LOCATION OF TERMINATION BLOCK IN THE SIGNALS CLOSET WITH THE OWNER. VA TO LIST PHONE NUMBERS FOR ANALOG CABLE TERMINATIONS.

5. FAX LOCATION. CONFIRM LOCATION OF TERMINATION BLOCK IN THE SIGNALS CLOSET WITH THE OWNER. VA TO LIST PHONE NUMBERS FOR ANALOG CABLE TERMINATIONS.

6. RE-INSTALL EXISTING CABLE FOR VIDEO SURVEILLANCE CAMERA. RE-INSTALL CAMERAS. COORDINATE FIELD-OF-VIEW WITH THE OWNER.

7. BEGIN CABLE LABELING IN "LEARNERS ROOM" C6001 AND CONTINUE CLOCKWISE.

8. VA WIRELESS ACCESS POINT LOCATION. PROVIDE ONE DATA.

9. EXISTING ACCESS CONTROL PANEL LOCATION. ADDITIONAL PANELS AND CARD READER MODULES NEEDED. CONTRACTOR TO VERIFY.

10. PROVIDE TWO (2) NETWORK SWITCHES, PART # CISCO WS-C3850-48F-L. PROVIDE TWO (2) UPLINK MODULES, PART # CISCO C3850-NM-4-1G. PROVIDE FOUR (4) AC POWER SUPPLIES, PART # PWR-C1-1100WAC. PROVIDE TWO (2) STACK CABLES, PART NUMBER # STACK-T1-50CM. PROVIDE TWO (2) POWER STACK CABLE, PART # CAB-SPWR-30CM. PROVIDE TWO (2) SMARTNET, PART # CON-SNT-WSC388FE. PROVIDE FOUR (4) SFP MODULE, PART # GLC-SX-MMD. COORDINATE LOCATION WITH OWNER PRIOR TO INSTALLATION.

BID DOCUMENTS - OCTOBER 05, 2018

10/05/18RESPONSIBLE CHARGE

D

SCD

DD

D D

SC

D D

D

APG

D

D

D

SC

D

D D

D

DSC

D

D

SC APG

SC APG

SC SC

DSC

SC

SC

APG

CR

CR

CR

CR

CR

CR

CR

CRCR

CR

EDC11

CR

CR

F

F F

F

F

F

110F F

FF

F

F

F

F

F

F

F

F

F

F

F

EDC12

EDC13

EDC10

EDC9

EDC14

EDC18

EDC16

EDC19

EDC17

F

F

N

N

N

N N

N

NN

N

N

NM

ND

ND

ND

ND

F

N

N

N

N

NN

N

N

R84" MH

CC 1

D

D

R84" MH

D

D D

D

D

D

D

D

EDC15

CR

N

N

N

ND

NS

NS

D

D

D

D

D DD D

D

D

D

DDDD

D DD

D

D

D

D D

D

D

D D

D D

D

D D

D

N

NNNN

N N N F

F

F

F

ND

ND

ND

N

N N NN

NNNN

N

APVA

APVA

APVA

APVA

APVA

APVA AP

VA

APVA

APVA

APVA

APVAAP

VAAPVA

APVA

APVA

APVA

APVA

APVA

APVA

D

D

EDC19

EDC22

APVA

CRD

N

D

D

D

60" MHVB I

D

D

HA

HD

SC APG

SC SC

F

F

DD

DD

AP

AP

SC SC

AP

1

1

2

1

1

3

701

703

TELE.ROOM

705

706

705A

707B

707A

740

725

7S2-7

739

T T

T

9

6

4

8

57

EXAMC7016

EXAMC7015

EXAM RM-2C7032-2

EXAM RM-2C7033-2

C7035-2

EXAM/PROCROOM-2

EXAM RM-2C7031-2

TEAM RM-2C7030-2

PAT TLT-2C7036-2

PAT TLT-2C7038-2

EXAM RM-2C7029-2

EXAM/PROC-4C7037-4

TYPICAL EXAM RM-2C7028-2

CORRIDOR-2C7-9-2

EXAM RM-2C7027-2

CLEAN STORAGE-2C7039-2

STAIR-22-7-2

SOILED UTILITY-2C7024-2

EXAMC7022

TEAM RMC7021 EXAM

C7020

EXAMC7019

TEAM RMC7018

EXAMC7017

CHECK OUT-2C7010-2

TEAM RM-2C7026-2

C7013

TYPICALTEAM RMEXAM

C7012EXAMC7011

RECEPT-3C7009-3

CORRIDORC7-10

WAITING ROOM-2C7007-2

PAT TLT-2C7008-2

HSKP-2C7006-2

C7005-2

BREAK RM/MAIL RM-2

LOCKERSC7001

LOCKERSC7003

STAFF TLT-2C7004-2

STAFF TLT-2C7002-2

MECH RM-2C7040-2

ELECC7025

TLT RMC7014

CORRIDOR-2C7-8-2

C-7059-2

C-7075-2

STAIR-21-7-2

C-7076

709

10

10

10

10

10

1010

10

10

10

10

10

10

10

10

10

10

10

10

10

11

707

724

1

C7-11

C7-10A-16

SHELLSPACE-16

C-9015CLOSET

C-9016CLOSET

C-9014

PROCESSING&

RECORDS

C-9013CLOSET

58CLOSET

57CLOSET

C-9010

HRSPECIALIZINGRECRUITMENT

&PLACEMENT

C-9027Room

C-9031CLOSET

C-9028

EMPLOYEE/LABORRELATIONS

C-9017

MEETINGROOM

C-9007BREAKROOM

C-9009STORAGE

C-9008STORAGE

C-9002

PERS.MANAG.

SPECIALIST

C-9005

PERS.MANAG.

SPECIALIST

C-9004

PERS.MANAG.

SPECIALIST

C-9003

PERS.MANAG.

SPECIALIST

C-9033Room

C-9037CLOSET

C-9038CLOSET

C-9032

MED.STAFF &NURSE

CREDENTIALING

C-9052

FIREEQUIPMENT

C-9051

ELEC.ROOM

C-9036

EMPLOYMENTINFORMATION

C9-3LOBBY

C-9050CLOSET

C-9039ENG.

C9-4LOBBY

C9-5CORRIDOR

C-9030

HRSPECIALIST

CLASSIFICATION

C-9035

HUMANRESOURCES

59

HUMANRESOURCES

C-9006

HUMANRESOURCES

12

12

13

12

PROJECT NO.

10/05/18COVERINGTECHNOLOGY DESIGN

C:\B

IM\M

odel

\201

7-91

021-

Tec

hnol

ogy-

Cen

tral

_RLC

ondy

.rvt

10/5

/201

8 10

:49:

33 A

M

2017-91021

1/8" = 1'-0"TA-107

1 LEVEL 7 FLOOR PLAN

1. GUEST WIRELESS ACCESS POINT LOCATION. PROVIDE ONE DATA.

2. COORDINATE DATA LOCATION WITH MECHANICAL CONTRACTOR.

3. EXISTING SIGNALS CLOSET. TERMINATE ALL NEW CABLING FROM THE 7TH FLOOR AT THIS LOCATION. REFER TO THE SPECIFICATIONS FOR DETAILS ON THE TERMINATION REQUIREMENTS.

4. BLACK ANALOG PHONE AND FAX LOCATION. CONFIRM LOCATION OF TERMINATION BLOCK IN THE SIGNALS CLOSET WITH THE OWNER. VA TO LIST PHONE NUMBERS FOR ANALOG CABLE TERMINATIONS.

5. FAX LOCATION. CONFIRM LOCATION OF TERMINATION BLOCK IN THE SIGNALS CLOSET WITH THE OWNER. VA TO LIST PHONE NUMBERS FOR ANALOG CABLE TERMINATIONS.

6. RE-INSTALL EXISTING CABLE FOR VIDEO SURVEILLANCE CAMERAS. RE-INSTALL CAMERAS. COORDINATE FIELD-OF-VIEW WITH THE OWNER.

7. HEALTHY VET KIOSK LOCATION.

8. NURSE CALL MASTER STATION LOCATION.

9. BEGIN CABLE LABELING IN "BREAK ROOM/MAIL ROOM" C7005 AND CONTINUE CLOCKWISE.

10. VA WIRELESS ACCESS POINT LOCATION. PROVIDE ONE DATA.

11. EXISTING ACCESS CONTROL PANEL LOCATION. ADDITIONAL PANELS AND CARD READER MODULES NEEDED. CONTRACTOR TO VERIFY.

12. UPON COMPLETION OF THE NEW CEILINGS, RE-CONNECT AP'S. CONFIRM THE AP'S ARE ACTIVATED. PERFORM SELF-CHECK WITH OWNER TO CONFIRM CONNECTION WITH AN OWNER PROVIDED DEVICE.

13. UPON COMPLETION OF THE NEW CEILINGS, RE-CONNECT PAGING SPEAKERS. CONFIRM THE PAGING SPEAKERS ARE FUNCTIONING PROPERLY VIA AUDIBLE TEST.

GENERAL PLAN NOTES:

1/8" = 1'-0"TA-107

2 LEVEL 7 FLOOR PLAN - ALTERNATE

1/8" = 1'-0"TA-107

3 LEVEL 9 FLOOR PLAN - PARTIAL

BID DOCUMENTS - OCTOBER 05, 2018

10/05/18RESPONSIBLE CHARGE

DM DM

EL EL

RX RX

CR

IP 2 DOORCONTROLLER

PB120V

DM DM

EL EL

RX RX

CR

PB120V

DATA DROP/POE

CONTROLLED CARD READER WITHOUTHANDICAP INTERFACE

NOTE: THIS DIAGRAM IS SCHEMATIC IN NATURE ONLY. IT IS INTENDED TOSHOW THE GENERAL CONFIGURATION OF THE SYSTEM. REFER TO THEDRAWINGS AND SPECIFICATION FOR THE EXACT WORK REQUIRED.

INTERIOR - CEILING RECESSED

~

2

3

1

CAMERA MOUNTING DETAIL NOTES1. EXISTING CAMERA TO BE RE-INSTALLED IN NEW CEILING.2. RE-PULL EXISTING DATA OUTLET AND RE-TERMINATE AT NEW CAMERA

LOCATION.3. PROVIDE NEW PATCH CABLE.

FINISH FLOOR

CEILING

FINISH FLOOR

CEILING

NON-SECURE SIDESECURE SIDE NON-SECURE SIDESECURE SIDE

1. MAGNETIC DOOR POSITION SWITCH.2. PROVIDE 0.5" CONDUIT FROM DOOR FRAME TO COMMON

SECURITY JUNCTION BOX ON SECURE SIDE OF DOOR PERDIVISION 26.

3. COMMON SECURITY JUNCTION BOX ON SECURE SIDE OF DOOR.(12"X12"X4" WITH SECURITY SCREW COVER) PER DIVISION 26.

4. PROVIDE 1" CONDUIT FROM COMMON SECURITY JUNCTION BOXBACK TO EITHER TR-01E OR TR-02E PER DIVISION 26.

5. ELECTRONIC DOOR LOCK.6. PROVIDE 0.75" CONDUIT FROM DOOR FRAME TO COMMON

SECURITY JUNCTION BOX ON SECURE SIDE OF DOOR PERDIVISION 26.

7. REQUEST TO EXIT SENSOR IN THE HARDWARE.8. WALL MOUNTED CREDENTIAL READER. PROVIDE 1-GANG BOX

AT 46" MH (UNLESS OTHERWISE NOTED) AND EXTEND 0.75"CONDUIT FROM BOX TO COMMON SECURITY JUNCTION BOX ONSECURE SIDE OF DOOR PER DIVISION 26.

86

5 7

2

1

4

5

686

5 75 7

5

6

1

2 2

3

4

3

EL

DETAIL NOTES

PROJECT NO.

10/05/18COVERINGTECHNOLOGY DESIGN

C:\B

IM\M

odel

\201

7-91

021-

Tec

hnol

ogy-

Cen

tral

_RLC

ondy

.rvt

10/5

/201

8 10

:49:

34 A

M

2017-91021

SCALE: NONE

CARD READER WITHOUT HANDICAP INTERFACE1

SCALE: NONE

IP CCTV MOUNTING DETAILS2

12" = 1'-0"TA-501

3 TECHNOLOGY DOOR ROUGH-IN

NOTES:

ELECTRONIC DOOR CONTROLS SCHEDULE

ED

C N

UM

BE

R

DO

OR

OP

EN

ING

NU

MB

ER

CONTROL LOCKS REQUEST TO EXIT DOOR MONITORAUTOMATIC DOOR

OPERATOR

SP

EC

IAL

DO

OR

NO

TE

SEAC INTERFACE POWER TYPE

QT

Y

FUNCTION LOCATION POSITION SWITCH L BOLTBOND

SENSOR MOTOR PUSHPLATE

RE

AD

ER

TO

D

FIR

E A

LAR

M

INT

ER

CO

M

PU

SH

BU

TT

ON

INT

RU

SIO

N A

LAR

M

PO

E /

PO

E+

VO

LTA

GE

LO

CA

L

RE

MO

TE

LO

CA

TIO

N

NO

TE

EP EL ES ML WL ALA

RM

SH

UN

T

UN

LOC

K

NO

TE

HA

RD

WA

RE

MO

TIO

N

WA

LL S

WIT

CH

NO

TE

QTY #P

#T

BA

LAN

CE

D

HIG

H S

EC

UR

ITY

RE

CE

SS

ED

SU

RF

AC

E

QTY QTY QTY EA

C IN

TE

RF

AC

E

QTY WIR

ELE

SS

1 601 24 TEL RM 85 1 1 DPDT 0 0 0 02 6-25 24 TEL RM 85 1 1 DPDT 0 0 0 03 633 24 TEL RM 85 1 1 DPDT 0 0 0 04 631 24 TEL RM 85 1 1 DPDT 0 0 0 05 618 24 TEL RM 85 1 1 DPDT 0 0 0 06 6S2-6 24 TEL RM 85 1 1 DPDT 0 0 0 07 604 24 TEL RM 85 1 1 DPDT 0 0 0 08 605 24 TEL RM 85 1 1 DPDT 0 0 0 09 705A 24 TEL RM 48 1 1 DPDT 0 0 0 010 706 24 TEL RM 48 1 1 DPDT 0 0 0 011 701 24 TEL RM 48 1 1 DPDT 0 0 0 012 703 24 TEL RM 48 1 1 DPDT 0 0 0 013 705 24 TEL RM 48 1 1 DPDT 0 0 0 014 707B 24 TEL RM 48 1 1 DPDT 0 0 0 015 709 24 TEL RM 48 1 1 DPDT 0 0 0 016 724 24 TEL RM 48 1 1 DPDT 0 0 0 017 740 24 TEL RM 48 1 1 DPDT 0 0 0 018 741 24 TEL RM 48 1 1 DPDT 0 0 0 019 7S2-7 24 TEL RM 48 1 1 DPDT 0 0 0 019 707 24 TEL RM 48 1 1 DPDT 0 0 1 122 725 24 TEL RM 48 1 1 DPDT 0 0 0 0

BID DOCUMENTS - OCTOBER 05, 2018

10/05/18RESPONSIBLE CHARGE

1

OUTLET TYPE "R"CATV-OUTLET

2-POSITION SINGLE GANG FACEPLATEWITH CLEAR LABEL WINDOWS:• ONE (1) MODULAR 8-POSITION JACK "GREEN"• ONE (1) CATEGORY 6 UTP CABLE "GREEN"• ONE (1) COAXIAL F CONNECTOR COUPLER• ONE (1) RG6 QUAD SHIELDED COAXIAL CABLECONDUIT PER DIVISION 26. JACKS, FACEPLATE, ANDCABLING PER DIVISION 27.

1

4

OUTLET TYPE "2" (DATA)

3

2

12" SLACK COILSTORED AT CONDUIT STUB

4-11/16" SQUARE X 2-7/8"DEEP BACKBOX

CEILING LINE FOR ACCESS POINT (AP) ANDVIDEO SURVEILLANCE CAMEA

(SOLID CEILING)

CEILING LINE

4-POSITION SINGLE GANG FACEPLATEWITH CLEAR LABEL WINDOWS:• TWO (2) MODULAR 8-POSITION JACK "GREEN"• TWO (2) CATEGORY 6 UTP CABLE "GREEN"CONDUIT PER DIVISION 26. JACKS, FACEPLATE, ANDCABLING PER DIVISION 27.

2

1" BUSHED CONDUITROUTED TO THE OVERHEADCABLE TRAY

12" SLACK COILSTORED AT CONDUIT STUB

1" BUSHED CONDUITROUTED TO THE OVERHEADCABLE TRAY

4-11/16" SQUARE X 2-7/8"DEEP BACKBOX

AP

1" BUSHED CONDUITROUTED TO THE OVERHEADCABLE TRAY

4-11/16" SQUARE X 2-7/8"DEEP BACKBOX

BOND TOCABLE TRAY

R D

CC

3

2

1

DETAIL NOTES1. SURFACE MOUNT UTP DATA JACK

ABOVE ACCESSIBLE CEILING.2. UTP DATA JACK3. PROVIDE BISQUIT OR SURFACE

MOUNTED BOX FOR "AP" AND "IP"CAMERA LOCATIONS.

FOR ACCESS POINT (AP) ANDVIDEO SURVEILLANCE CAMEA

(LAY-IN CEILING)

AI

V

HDMI

1-1/4" CONDUIT

DATA DROP TO TR

CATV DROP TO TR

DUPLEX POWER OUTLET

DUPLEX POWER OUTLET

DATA

HDMI

DUPLEX POWER OUTLET

2

FLOOR

CEILING

~

PROVIDE 12" SLACK COIL AT STUB-UP LOCATION

60" MH

1-1/4" CONDUIT STUB-UPABOVE CEILING

FSR PWB-200

CI

V

HDMI

DATA DROP TO TR

CATV DROP TO TR

DUPLEX POWER OUTLET

DUPLEX POWER OUTLET

FLOOR

55' - 3"60" MH

1-1/4" CONDUIT

CEILING

~

1-1/4" CONDUIT STUB-UPABOVE CEILING

PROVIDE 12" SLACK COIL AT STUB-UP LOCATION

FSR PWB-200

DATA

DUPLEX POWER OUTLET

1

1-1/4" CONDUIT STUB-UPABOVE CEILING

~

PROVIDE 12" SLACK COILAT STUB-UP LOCATION

R

DATA DROP TO TR

CATV DROP TO TR

DUPLEX POWER OUTLET

DUPLEX POWER OUTLET

FLOOR

84" MH

CEILING

~

1-1/4" CONDUIT STUB-UPABOVE CEILING.

PROVIDE 12" SLACK COIL AT STUB-UP LOCATION.

FSR PWB-200

1

2

21

1

PROJECT NO.

10/05/18COVERINGTECHNOLOGY DESIGN

C:\B

IM\M

odel

\201

7-91

021-

Tec

hnol

ogy-

Cen

tral

_RLC

ondy

.rvt

10/5

/201

8 10

:49:

36 A

M

2017-91021

1/8" = 1'-0"TA-502

1 TECHNOLOGY OUTLET DETAILS 1/8" = 1'-0"TA-502

4 AV HIGH/LOW OUTLET WITH HDTV - FLOOR BOX 2 - LEARNER'S ROOM 1/8" = 1'-0"TA-502

5 AV HIGH/LOW OUTLET WITH HDTV

1/8" = 1'-0"TA-502

6 FLOOR BOX 1 - LEARNER'S ROOM 1/8" = 1'-0"TA-502

7 AV HIGH/LOW OUTLET - DISPLAY MONITORS

3/4" = 1'-0"TA-502

3 SIGNALS CLOSET EQUIPMENT RACK

NOTES1. 1U WIRE MANAGER.2. 1U 48 PORT PATCH PANEL.

TYPICAL NEW MODULAR PATCH PANEL CONFIGURATION

BID DOCUMENTS - OCTOBER 05, 2018

10/05/18RESPONSIBLE CHARGE