AGC Automatic Gen-set Controller DATA SHEET

15
AGC Automatic Gen-set Controller DATA SHEET Operation modes Automatic mains failure Island operation Fixed power/base load Peak shaving Load take over Mains power export Engine control Start/stop sequences Run and stop coil Relay outputs for governor control Protection (ANSI) Overcurrent, 4 levels (51) Reverse power, 2 levels (32) Multi inputs, 3 configurable Oil pressure, 2 levels Cooling water, 2 levels Fuel level, 2 levels Document no.: 4921240295K SW version 3.40.0 or later Display Push-buttons for start and stop Push-buttons for breaker operations Status texts Alarm indication Prepared for remote mounting Prepared for additional remote displays M-logic (Micro PLC) Simple logic configuration tool Selectable input events Selectable output commands General USB interface to PC Free PC utility software for commissioning Mini SCADA in PC utility software 3/2/1-phase monitoring Close before excitation

Transcript of AGC Automatic Gen-set Controller DATA SHEET

AGC Automatic Gen-set Controller DATA SHEET

Operation modes • Automatic mains failure • Island operation • Fixed power/base load • Peak shaving • Load take over • Mains power export

Engine control • Start/stop sequences • Run and stop coil • Relay outputs for governor control

Protection (ANSI) • Overcurrent, 4 levels (51) • Reverse power, 2 levels (32) • Multi inputs, 3 configurable • Oil pressure, 2 levels • Cooling water, 2 levels • Fuel level, 2 levels

Document no.: 4921240295K SW version 3.40.0 or later

Display • Push-buttons for start and stop • Push-buttons for breaker operations • Status texts • Alarm indication • Prepared for remote mounting • Prepared for additional remote displays

M-logic (Micro PLC) • Simple logic configuration tool • Selectable input events • Selectable output commands

General

• USB interface to PC • Free PC utility software for commissioning • Mini SCADA in PC utility software • 3/2/1-phase monitoring • Close before excitation

Data sheet Automatic Gen-set Controller

DEIF A/S Page 2 of 15

Application The Automatic Gen-set Controller is a microprocessor based control unit containing all necessary functions for protection and control of a gen-set. It contains all necessary 3-phase measuring circuits and all values and alarms are presented on the LCD display. The AGC is a compact all-in-one unit designed for the following applications:

• Automatic mains failure • Island operation • Fixed power/base load • Peak shaving • Load take over • Mains power export (fixed power to mains)

Optional applications:

• Multiple gen-sets, load sharing • Power management (island operation) • Power management (island operation, split bus) • Power management (island operation, ring bus) • Power management (parallel with mains) • Power management (parallel with mains, split

bus) • Power management (parallel with mains, ring

bus) The display is separate and can be installed directly on the main unit or in the front of the switchboard door (requires option J1 - display cable). Additional displays can be installed within 200m. The AGC is supplied with an engine interface I/O card with separate power supply and processor. The card is equipped with the following I/Os:

Test The available gen-set modes except island operation include a test mode. The test can be configured in 3 different ways. Simple: Gen-set starting and running for a preset time.

Generator breaker is open during the test. Load: Gen-set starting, synchronisation of the

generator breaker. The test is carried out for a preset period of time at a fixed power set point parallel to the mains.

Full: Gen-set starting, synchronisation of the

generator breaker, de-load and opening of the mains breaker. The test is carried out for a preset period of time after which the load is transferred back to the mains connection.

Setup Setup is easily done via a menu structure in the display (password protected) or via the USB PC connection and the multi-line 2 Windows® based PC utility software. The PC utility software can be downloaded free of charge from www.deif.com/Download_centre. The utility software offers additional features such as monitoring of all relevant information during commissioning, saving and downloading of settings and downloading of software updates. Options In order to perfectly match the product solution to specific applications, the functionality of the AGC can be equipped with a number of available options. The options selected by the customer will be integrated in the standard AGC, hereby securing the same user interface unaffected by whether the application needs a highly complex or a more basic gen-set controller. Please refer to pages 8, 9 and 10 for the options available. Unit definitions AGC: The standard control unit designed for a

number of applications (1-9). An extensive list of hardware and software options is available for the AGC.

AGC mains: A power management control unit used in

the parallel with mains power management application (6-9). Several options are available for the AGC mains.

AGC BTB: A power management control unit used in

the power management application to split the busbar (8). Several options are available for the AGC BTB.

M-logic (Micro PLC) This configuration tool is part of the PC utility software which is free of charge. With this tool it is possible to customise the application to your needs. It is possible to dedicate specific functions or logical conditions to different inputs and outputs.

In-/outputs Available 4-20mA Digital inputs PT100 PT1000 VDO

Multi inputs:

0-40V DC

3 (3)

Digital inputs 7 (6) RPM (MPU) 1 Relays 4 CANbus comm. 2

The number in parenthesis indicates the number of user configurable in-/outputs.

The AGC can operate in automatic mains failure mode as a secondary mode regardless of the type of application - except the island applications.

The two CAN communications are only available, if option G4, G5 or H5 is selected.

Data sheet Automatic Gen-set Controller

DEIF A/S Page 3 of 15

Single line application diagrams

Standard 1. Automatic mains failure and fixed power/base load

2. Island

3. Peak shaving, load take over and

mains power export

Optional

4. Multiple gen-sets, load sharing

5-9. Power management

See separate page in this data sheet

Alarm inhibi tSelf check okPower

Engine CANPMS CAN DisplayService port

423937 38 40 41 484543 44 46 47 49 50 51 52 645453 55 5756 58 616059 6362 6665 67 68 7069 71 72

79 80 81 82 8483 8685 87 88 89 9390 91 92 94 95 979673 74 75 76 77 78

3

3

Alarm inhibitSelf check okPower

Engine CANPMS CAN DisplayService port

423937 38 40 41 484543 44 46 47 49 50 51 52 645453 55 5756 58 616059 6362 6665 67 68 7069 71 72

79 80 81 82 8483 8685 87 88 89 9390 91 92 94 95 979673 74 75 76 77 78

3

33

787776757473 96 979594929190 9389888785 8683 8482818079

727169 70686765 6662 6359 60 615856 575553 54 645251504947464443 45 4841403837 39 42

Service port DisplayPMS CANEngine CAN

PowerSelf check okAlarm inhibitAlarm inhibit

Self check okPower

Engine CANPMS CAN DisplayService port

423937 38 40 41 484543 44 46 47 49 50 51 52 645453 55 5756 58 616059 6362 6665 67 68 7069 71 72

79 80 81 82 8483 8685 87 88 89 9390 91 92 94 95 979673 74 75 76 77 78

3

Alarm inhibitSelf check okPower

Engine CANPMS CAN DisplayService port

423937 38 40 41 484543 44 46 47 49 50 51 52 645453 55 5756 58 616059 6362 6665 67 68 7069 71 72

79 80 81 82 8483 8685 87 88 89 9390 91 92 94 95 979673 74 75 76 77 78

Data sheet Automatic Gen-set Controller

DEIF A/S Page 4 of 15

Power management (option G4/G5)

Description The AGC can be equipped with a power management option (G4 or G5). Using this possibility, the AGC will be able to handle applications with up to

• 16 mains incoming • 16 mains breakers • 16 tie breakers • 8 bus tie breakers (BTBs) • 16 generators (256 on request) • 16 generators • 16 generator breakers

The basic functions are:

• All 56 breakers can be synchronised by choice • Load dependent start/stop operation • Priority selection of gen-sets • Priority selection of mains • Redundant communication between the

controllers • Plant divided into sections for individual

functionality • Selectable mains priority and parallel

operation • The plant mains failure sequence can call for

support on local plant sections • Load management • Quick setup/broadcast • Asymmetric load sharing • CAN flags • Droop frequency/voltage • Heavy consumer (HC) • Non-essential load (NEL)/load shedding • Secured mode • Base load • Multi-master system

In a multi-master system, all vital data is broadcasted from all units to all units, giving all units knowledge of their own position in the application. This philosophy makes the application immune to a failing master controller. Application The plant modes supported by the power management options are:

• Automatic mains failure/ATS • Island operation • Fixed power/base load • Peak shaving • Load take over • Mains power export (fixed power to mains)

The plant modes are configurable and it is possible to change the plant mode on the fly both in single gen-set and in power management applications. The plant can be divided into sections by several bus tie breakers, making it possible to run different plant modes in each section. Configuration The setup of the application is easily configured using a computer and the DEIF PC utility software.

Your PC tool visualises it - the AGC realises it. Load management The load management is primarily handled by the tie breakers. Functions are available to ensure sufficient power capacity to handle the load either in terms of number of gen-sets or by soft starting the load. If a certain level of available power on the busbar is required to connect a load group, functions are available both for starting additional generators and relays can be configured to activate when a specific level of available power is reached. Load dependent operation The load dependent starting and stopping of the gen-sets is based on a power available calculation. The next generator will start when the available power decreases below the adjustable set point. It will stop when too much power is available.

Data sheet Automatic Gen-set Controller

DEIF A/S Page 5 of 15

Priority selection Priority routines are individually made for the mains in the plant sections and for the gen-sets. The mains priority routines in the AGC mains are:

• Selected primary mains • Parallel mains

The gen-set priority routines in the AGC are:

• Manual selection based on ID • Running hours • Fuel optimising calculating the best

combination of generator kW size and the plant load. Works with up to 16 gen-sets

Redundant AGC mains and CANbus In emergency systems requiring extra operation reliability, redundant AGC mains units and redundant CANbus communication lines can be used to provide back-up.

Redundant AGC mains units are only supported in the application: Dual mains (7).

Data sheet Automatic Gen-set Controller

DEIF A/S Page 6 of 15

Optional power management applications

5. Island operation

6. Parallel with mains

The tie breaker is selectable depending on applicational needs.

7. Parallel with 2 mains/dual mains application

The tie breaker is selectable depending on applicational needs.

Alarm inhibi tSelf check okPower

Engine CANPMS CAN Dis playService port

423937 38 40 41 48

Alarm inhibitSelf check okPower

Engine CANPMS CAN Dis playService port

423937 38 40 41 484543 44 46 47 49 50 51 52 645453 55 5756 58 616059 6362 6665 67 68 7069 71 72

79 80 81 82 8483 8685 87 88 89 9390 91 92 94 95 979673 74 75 76 77 78

787776757473 96 979594929190 9389888785 8683 8482818079

727169 70686765 6662 6359 60 615856 575553 54 645251504947464443 45 4841403837 39 42

Service port DisplayPMS CANEngine CAN

PowerSelf check okAlarm inhibi t A larm inhibit

Sel f check okPower

Engine CANPMS CAN DisplayService port

423937 38 40 41 484543 44 46 47 49 50 51 52 645453 55 5756 58 616059 6362 6665 67 68 7069 71 72

79 80 81 82 8483 8685 87 88 89 9390 91 92 94 95 979673 74 75 76 77 78

3

33

3

787776757473 96 979594929190 9389888785 8683 8482818079

727169 70686765 6662 6359 60 615856 575553 54 645251504947464443 45 4841403837 39 42

Service port DisplayPMS CANEngine CAN

PowerSelf check okAlarm inhibit

Alarm inhibitSel f check okPower

Engine CANPMS CAN DisplaySer vice port

423937 38 40 41 484543 44 46 47 49 50 51 52 645453 55 5756 58 616059 6362 6665 67 68 7069 71 72

79 80 81 82 8483 8685 87 88 89 9390 91 92 94 95 979673 74 75 76 77 78

4543 44 46 47 49 50 51 52 645453 55 5756 58 616059 6362 6665 67 68 7069 71 72

79 80 81 82 8483 8685 87 88 89 9390 91 92 94 95 979673 74 75 76 77 78

787776757473 96 979594929190 9389888785 8683 8482818079

727169 70686765 6662 6359 60 615856 575553 54 645251504947464443 45 4841403837 39 42

787776757473 96 979594929190 9389888785 8683 8482818079

727169 70686765 6662 6359 60 615856 575553 54 645251504947464443 45 4841403837 39 42

Service port DisplayPMS CANEngine CAN

PowerSelf check okAlarm inhibit

Service port DisplayPMS CANEngine CAN

PowerSelf check okAlarm inhibit

Alarm inhibitSelf check okPower

Engine CANPMS CAN DisplayService port

423937 38 40 41 484543 44 46 47 49 50 51 52 645453 55 5756 58 616059 6362 6665 67 68 7069 71 72

79 80 81 82 8483 8685 87 88 89 9390 91 92 94 95 979673 74 75 76 77 78

3

3 3

787776757473 96 979594929190 9389888785 8683 8482818079

727169 70686765 6662 6359 60 615856 575553 54 645251504947464443 45 4841403837 39 42

Service port DisplayPMS CANEngine CAN

PowerSelf check okAlarm inhibit Alarm inhibit

Self check okPower

Engine CANPMS CAN DisplayService port

423937 38 40 41 484543 44 46 47 49 50 51 52 645453 55 5756 58 616059 6362 6665 67 68 7069 71 72

79 80 81 82 8483 8685 87 88 89 9390 91 92 94 95 979673 74 75 76 77 78

33

Data sheet Automatic Gen-set Controller

DEIF A/S Page 7 of 15

Optional power management applications

8. H-coupling

The tie breaker controlled by the AGC mains is selectable depending on applicational needs.

9. X mains and 1 DG

The tie breaker controlled by the AGC mains is selectable depending on applicational needs.

Data sheet Automatic Gen-set Controller

DEIF A/S Page 8 of 15

Available options

Option Description Slot

no. Option type

Note

A Loss of mains protection package A1 Over- and undervoltage (generator and busbar/mains)

(27/59) Over- and underfrequency (generator and busbar/mains) (81) Voltage unbalance (busbar) (60) Vector jump (78) df/dt (ROCOF) (81)

Software

A2 Over- and undervoltage (generator and busbar/mains) (27/59) Over- and underfrequency (generator and busbar/mains) (81) Voltage unbalance (busbar) (60) df/dt (ROCOF) (81)

Software

A3 Over- and undervoltage (generator and busbar/mains) (27/59) Over- and underfrequency (generator and busbar/mains) (81) Voltage unbalance (busbar) (60) Vector jump (78)

Software

A4 Positive sequence (mains voltage low) (27) Software A5 Directional overcurrent (67) Software

B Generator/busbar/mains protection package B1 Over- and undervoltage (generator and busbar/mains)

(27/59) Over- and underfrequency (generator and busbar/mains) (81) Voltage unbalance (busbar) (60)

Software

C Generator add-on protection package C1 Over- and undervoltage (27/59)

Over- and underfrequency (81) Overload (32) Peak current (50) Current unbalance (46) Voltage unbalance (60) Reactive power import (excitation loss) (40) Reactive power export (overexcitation) (40) Voltage dependent overcurrent (92)

Software

C2 Negative sequence voltage high (47) Negative sequence current high (46) Zero sequence voltage high (59) Zero sequence current high (50)

Software

D Voltage/VAr/PF control Not available for AGC mains and AGC bus tie

D1 Constant voltage control (stand-alone) Constant reactive power control (parallel with mains) Constant power factor control (parallel with mains) Reactive load sharing (island paralleling with other generators)

Software Not with EF2

E and F Analogue controller and transducer outputs E1 2 x +/-25mA (GOV/AVR or transducer)

4 Hardware Not with E2, EF2, EF4 or EF5

AVR output requires D1 E2 2 x 0(4)...20mA (GOV/AVR or transducer) 4 Hardware Not with E1, EF2, EF4 or EF5

AVR output requires D1 EF2 1 x +/-25mA (GOV/AVR or transducer)

1 x 0(4)...20mA (GOV/AVR or transducer) 4 Hardware Not with E1, E2, EF4 or EF5

AVR output requires D1 EF4 1 x +/-25mA (GOV/AVR or transducer)

2 x relay outputs (GOV/AVR or configurable) 4 Hardware Not with E1, E2, EF2 or EF5

AVR output requires D1 EF5 1 x PWM (Pulse Width Modulated) output for CAT GOV

+/-20mA for AVR. 2 x relay outputs for AVR 4 Hardware Not with E1, E2, EF2 or EF4

AVR output requires D1 F1 2 x 0(4)...20mA (transducer) 6 Hardware Not with H8.2, M13.6, M14.6 or M15

Options E1, E2, EF2 and EF4 are used for GOV/AVR control. 4 relays are used as standard in the AGC for GOV/AVR control. If selected, these options will replace the 4 relays.

Data sheet Automatic Gen-set Controller

DEIF A/S Page 9 of 15

Option Description Slot

no. Option type

Note

G Load sharing/power management G3 Load sharing with analogue lines

3 Hardware/

software If M12 is present, G3 is a software option Not available for AGC mains and AGC bus tie

G4 Power management, 16 gen-sets, 8 bus tie breakers 7 Software Not with H7 or G5 G5 Power management, 16 mains, 16 gen-sets, 8 bus tie

breakers 7 Software Not with H7 or G4

H Serial communication H2 Modbus RTU (RS485) 2 Hardware Not with H3, H8.2 H3 Profibus DP 2 Hardware Not with H2, H8.2 H5 CANbus:

MTU (ADEC and MDEC) and all J1939 engine comm. 8 Hardware Not with H6, H7, M13.8, M14.8, M15.8

or H8.8 Not available for AGC mains and AGC bus tie

H6 Cummins GCS 8 Hardware Not with H5, H7, M13.8, M14.8, M15.8 or H8.8 Not available for AGC mains and AGC bus tie

CANbus (J1939): H7 Caterpillar Cummins CM850/570 Detroit Diesel (DDEC) Deutz (EMR) Iveco (NEF/CURSOR) John Deere (JDEC)

Perkins Scania (EMS) Scania (EMS S6) Volvo Penta (EMS) Volvo (EMS2)

7 Software Not with H5, H6 or G5 Not available for AGC mains and AGC bus tie

H8.X External I/O modules 2, 8 Hardware H8.2: Not with H2, H3 H8.8: Not with H5, H6, M13.8, M14.8 or M15.8

H11 LED I/F card w/RS232 service port Hardware Not with N Class 1.0 measurements

J Cables J1 Display cable with plugs, 3 m. UL94 (V1) approved Other J2 Display cable with plugs, 6 m. UL94 (V1) approved Other J3 PC cable for utility software (RS232) 3 m. UL94 (V1) approved Other Only with H11 J4 PC cable for N option programming (Ethernet cable crossed),

3 m. UL94 (V1) approved Other

J6 Display cable with plugs, 1 m. UL94 (V1) approved Other J7 PC cable for utility software (USB) 3 m. UL94 (V1) approved Other Not with H11 J8 Display CAN cable for connection to display in the Remote

Maintenance Box Other

K Documentation K1 Designer’s Reference Handbook (hard copy) Other K2 CD-ROM with complete documentation Other

L Display gasket for IP54 Other Standard is IP52 M Binary and analogue I/Os

M12 13 binary inputs, 4 relay outputs, configurable 3 Hardware/ software

If G3 is present, M12 is a software option

M13.X 7 binary inputs, configurable 6, 8 Hardware M13.6: Not with F1, M14.6 or M15 M13.8: Not with H5, H6, M14.8, M15.8 or H8.8

M14.X 4 relay outputs, configurable 6, 8 Hardware M14.6: Not with F1, M13.6 or M15 M14.8: Not with H5, H6, M13.8, M15.8 or H8.8

M15.X 4 analogue inputs, configurable, 4...20mA 6, 8 Hardware M15.6: Not with F1, M13.6, M14.6 or M15.8 M15.8: Not with H5, H6, M13.8, M14.8, H8.8 or M15.6

N N-Options (N3) N - Modbus TCP/IP

- SMS/e-mail alarms - Advanced logging

Hardware

P Printer P1 Event and alarm printer software Software Only with H11

Data sheet Automatic Gen-set Controller

DEIF A/S Page 10 of 15

Option Description Slot

no. Option type

Note

Q Measurement accuracy Q1 Verified class 0.5 Other Not with H11

X Display X2 Additional standard display. CANbus comm. Other Two X2 options can be ordered for each

AGC unit Only available if the AGC unit is ordered with a display

X3 Additional operator panel (AOP-1): 16 configurable LEDs and 8 configurable push-buttons

Other X4 Additional operator panel (AOP-2): 16 configurable LEDs, 8

configurable buttons and 1 status relay. CANbus comm. Other Five X4 options can be ordered for each

AGC unit Only available if the AGC unit is ordered with a display

Y Display layout Y1 AGC display for island operation (no mains breaker) Other

(ANSI# as per IEEE Std C37.2-1996 (R2001) in parenthesis).

Please notice that not all options can be selected for the same unit. Please refer to page 12 in this data sheet for further information about the location of the options in the unit.

Data sheet Automatic Gen-set Controller

DEIF A/S Page 11 of 15

Principle diagrams

AGC

AGC mains

DEIF supplies a complete range of current transformers (DCT range of CTs), power supplies (DCPrange), meters (DQ range) and transducers (TAS range) that are suitable for use with our range of generator controls and protection relays - please see www.deif.com for full details.

-+

65

50

Hz

45

65

50

Hz

45

-+

Data sheet Automatic Gen-set Controller

DEIF A/S Page 12 of 15

Hardware overview

Besides the hardware options shown on this page, it is possible to select the software options mentioned in the chapter ‘Available options’.

There can only be one hardware option in each slot. It is e.g. not possible to select option H2 and option H3 at the same time, because both options require a PCB in slot #2.

Eth

erne

t

7877

7675

7473

9697

9594

9291

9093

8988

8785

8683

8482

8180

79

7271

6970

6867

6566

6263

5960

6158

5657

5553

5464

5251

5049

4746

4443

4548

4140

3837

3942

US

B M

emor

yS

ervi

ce p

ort

Dis

play

Eth

erne

tP

MS

CAN

Eng

ine

CA

N

US

B

Pow

erS

elf c

heck

ok

Ala

rm in

hibi

t

N: Modbus TCP/IP SMS/e-mail alarms Advanced logging

G3: Active power load sharing Reactive power load sharing (requires D1)

M12: 13 x digital inputs 4 x relay outputs

8-36V DC supply, 11W 1 x status output relay 5 x relay outputs 2 x pulse outputs (kWh, kVArh) 5 x digital inputs

3 x generator voltage 3 x generator current 3 x busbar/mains voltage

M15.6: 4 x 4…20mA inputs

M13.6: 7 x digital inputs

F1: 2 x 0(4)…20mA out, transducer

M14.6: 4 x relay outputs

H11: RS232 service port

E1: 2 x +/-20mA out

EF2: 1 x +/-20mA out 1 x 0(4)…20mA out

EF4: 1 x +/-20mA out 2 x relay

M14.4: 4 x relay (standard)

E2: 2 x 0(4)…20mA out

Slot #4, term. 65-72 Governor, AVR, in-/outputs

Slot #2, term. 29-36 Communication

Slot #1, term. 1-28 Power supply (std.)

Slot #3, term. 37-64 In-/outputs/load sharing

Slot #6, term. 90-97 In-/outputs

LED I/F

Slot #8, term. 126-133 Engine comm., in-/outputs

Slot #7, term. 98-125 Engine I/F (std.)

Slot #5, term. 73-89 AC measuring (std.)

LED I/F

8-36V DC supply, 5W 1 x magnetic pick-up (MPU) 3 x multi inputs 7 x digital inputs 4 x relay outputs

G4/G5: Power management

H7: J1939

H2: Modbus RTU (RS485)

H3: Profibus DP

H8.2: Ext. I/O modules

H5: MTU (MDEC) + J1939 (option H7)

M13.8: 7 x digital inputs

M14.8: 4 x relay outputs

H6: Cummins GCS

H8.8: Ext. I/O modules

EF5: 1 x +/-20mA out 1 x PWM out 2 x relay

M15.8: 4 x 4…20mA inputs

Data sheet Automatic Gen-set Controller

DEIF A/S Page 13 of 15

Technical specifications

Accuracy: Class 1.0 Class 0.5 with option Q1

Positive, negative and zero sequence alarms: Class 1 within 5% voltage unbalance

Class 1.0 for neg. seq. current

Fast overcurrent: 3% of 350%*In

Analogue outputs: Class 1.0 according to total range

Option EF4: Class 4.0 according to total range

To EN60688/IEC 688 Operating temp.: -25…70οC (-13...158ο F)

(UL/cUL Listed: Max. surround-ing air temp.: 55οC/131οF)

Storage temp.: -40…70οC (-40...158ο F) Climate: Class HSE, to DIN 40040 Meas. voltage: 100-690V AC +/-20%

(UL/cUL Listed: 480V AC phase-phase)

Consumption: Max. 0.25VA/phase Meas. current: -/1 or -/5A AC (UL/cUL Listed: From CTs 1-5A)

Consumption: Max. 0.3VA/phase Current overload: 4 x In continuously 20 x In, 10 sec. (max. 75A) 80 x In, 1 sec. (max. 300A) Meas. frequency: 30…70Hz Aux. supply: Terminals 1 and 2: 12/24V DC (8...36V

continuously, 6V 1 sec.) Max. 11W consumption

Terminals 98 and 99: 12/24V DC (8...36V

continuously, 6V 1 sec.) Max. 5W consumption

The aux. supply inputs are to be protected by a 2A slow blow fuse

(UL/cUL Listed: AWG 24) Binary inputs: Optocoupler, bi-directional ON: 8…36V DC Impedance: 4.7kΩ OFF: <2V DC Analogue inputs: -10…+10V DC: Not galvanically separated Impedance: 100kΩ

0(4)…20mA: Impedance: 50Ω Not galvanically separated

RPM (MPU): 2…70V AC, 10…10000Hz, 250…3000Ω

Multi inputs: 0(4)…20mA: 0-20mA, +/-1% Not galvanically separated

Binary: Max. resistance for ON detection: 100Ω

Not galvanically separated

PT100/1000: -40…250οC, +/-1%

Not galvanically separated To IEC 751 and EN60751

VDO: 0…1700Ω, +/-2% Not galvanically separated

V DC: 0…40V DC, +/-1% Not galvanically separated

Relay outputs: Electrical rating: 250V AC/30V DC, 5A

(UL/cUL Listed: 250V AC/24V DC, 2A resistive load)

Thermal rating @ 50οC: 2A: Continuously 4A: tON = 5 sec., tOFF = 15 sec.

(Unit status output: 1A) Open collector outputs: Supply: 8…36V DC, max. 10mA Analogue outputs: 0(4)...20mA and +/-25mA Galvanically separated Active output (internal supply) Load max. 500Ω

(UL/cUL Listed: Max. 20mA output)

Update rate: Transducer output: 250 ms Regulator output: 100 ms Load sharing lines: -5…0…+5V DC, Impedance: 23.5 kΩ Galv. separation: Between AC voltage, AC current

and other I/Os: 3250V AC, 50Hz, 1 min.

Between analogue outputs and other I/Os: 500V DC, 1 min.

Between binary input groups and other I/Os: 500V DC, 1 min.

Data sheet Automatic Gen-set Controller

DEIF A/S Page 14 of 15

Response times: (Delay set to min.)

Busbar: Over-/undervoltage: < 50ms Over-/underfrequency: < 50ms Voltage unbalance: <250ms

Generator: Reverse power: <250ms Overcurrent: <250ms Fast overcurrent: < 40ms Directional overcurrent <100ms Over-/undervoltage: <250ms Over-/underfrequency: <350ms Overload: <250ms Current unbalance: <250ms Voltage unbalance: <250ms React. power import: <250ms React. power export: <250ms Voltage dep. I>: <250ms Negative sequence I: <500ms Negative sequence U: <500ms Zero sequence I: <500ms Zero sequence U: <500ms Overspeed: <500ms Digital inputs: <250ms Emergency stop: <200ms Multi inputs: <800ms Wire failure: <600ms

Mains: df/dt (ROCOF): <130ms (4 periods) Vector jump: < 40ms Positive sequence: < 60ms Mounting: DIN-rail mount or base mount

with 6 screws Safety: To EN 61010-1, installation

category (overvoltage category) III, 600V, pollution degree 2

To UL 508 and CSA 22.2 no. 14-05, overvoltage category III, 300V, pollution degree 2

EMC/CE: To EN 61000-6-1/2/3/4 SS4631503 (PL4) and IEC 255-3 Material: All plastic materials are self-

extinguishing according to UL94 (V1)

Plug connec- tions: AC current: 0.2-4.0 mm2 stranded wire (UL/cUL Listed: AWG 18)

AC voltage: 0.2-2.5 mm2 stranded wire (UL/cUL Listed: AWG 20)

Relays: (UL/cUL Listed: AWG 22)

Terminals 98-116: 0.2-1.5 mm2 stranded wire (UL/cUL Listed: AWG 24)

Other: 0.2-2.5 mm2 stranded wire (UL/cUL Listed: AWG 24)

Display: 9-pole Sub-D female

Service port: USB A-B Protection: Unit: IP20

Display: IP52 (IP54 with gasket: Option L)

(UL/cUL Listed: Type Complete Device, Open Type)

To IEC 529 and EN 60529 Governors: Multi-line 2 interfaces to all governors,

including GAC, Barber-Colman, Woodward and Cummins

See interfacing guide at www.deif.com

Approvals: UL and cUL UL markings: Wiring: Use 60/75οC copper conductors only

Mounting: For use on a flat surface of type 1

enclosure

Installation: To be installed in accordance with the

NEC (US) or the CEC (Canada)

AOP-2: Maximum ambient temperature: 60οC

Wiring: Use 60/75οC copper conductors only

Mounting: For use on a flat surface of type 3

(IP54) enclosure Main disconnect must be provided by

installer

Installation: To be installed in accordance with the

NEC (US) or the CEC (Canada)

DC/DC converter for AOP-2: Tightening torque: 0.5Nm (4.4lb-in)

Wire size: AWG 22-14 Weight: Base unit: 1.6 kg (3.5 lbs.) Option J1/J3/ J4/J6/J7: 0.2 kg (0.4 lbs.) Option J2: 0.4 kg (0.9 lbs.) Display: 0.4 kg (0.9 lbs.)

Data sheet Automatic Gen-set Controller

Unit dimensions in mm (inches)

Order specifications

144.

0 (5

.669

)

120.0 ( 4.724)230.0 (9.055)

165.

0 (6

.496

)20

.0 (0

.787

)11

5.0

(4.5

28)

220.0 (9.055)

115.0 (4.528)

DEIF A/S, Frisenborgvej 33 DK-7800 Skive, Denmark Tel.: +45 9614 9614, Fax: +45 9614 9615 E-mail: [email protected], URL: www.deif.com

Due to our continuous development we reserve the right to supply equipment which may vary from the described.

The AGC mains unit is only usable with option G5, this option is already included when ordered. The AGC bus tie unit is only usable with option G4 or G5.

Specify the AGC type: DG/mains/BTB.