Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75...

78
ENGINEERING TOMORROW Panduan Operasi VLT ® AutomationDrive FC 301/302 0.25–75 kW www.DanfossDrives.com

Transcript of Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75...

Page 1: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

ENGINEERING TOMORROW

Panduan OperasiVLT® AutomationDrive FC 301/3020.25–75 kW

www.DanfossDrives.com

Page 2: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75
Page 3: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Daftar Isi

1 Pendahuluan 3

1.1 Tujuan Manual 3

1.2 Sumber Tambahan 3

1.3 Versi Manual dan Perangkat Lunak 3

1.4 Gambaran Produk 3

1.5 Persetujuan dan Sertifikasi Tipe 5

2 Keselamatan 6

2.1 Simbol Keselamatan 6

2.2 Teknisi Yang Cakap 6

2.3 Petunjuk Keselamatan 6

3 Instalasi Mekanis 8

3.1 Membuka kemasan 8

3.1.1 Item Yang Disertakan 8

3.2 Lingkungan Pemasangan 8

3.3 Pemasangan 8

4 Instalasi Kelistrikan 10

4.1 Petunjuk Keselamatan 10

4.2 EMC-sesuai Instalasi 10

4.3 Arde 10

4.4 Skematis Kabel 12

4.5 Sambungan Motor 14

4.6 Sambungan Sumber Listrik AC 15

4.7 Kabel Kontrol 15

4.7.1 Safe Torque Off (STO) 15

4.7.2 Kontrol Rem Mekanis 15

4.8 Daftar Periksa Instalasi 16

5 Uji Coba 18

5.1 Petunjuk Keselamatan 18

5.2 Operasi Panel Kontrol Lokal 19

5.3 Persiapan Sistem 20

6 Konfigurasi I/O Dasar 21

7 Pemeliharaan, Diagnostik, dan Pemecahan Masalah 23

7.1 Perawatan dan Servis 23

7.2 Jenis Peringatan dan Alarm 23

7.3 Daftar Peringatan dan Alarm 24

Daftar Isi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 1

Page 4: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

8 Spesifikasi 33

8.1 Data Kelistrikan 33

8.1.1 Sumber Listrik 200-240 V 33

8.1.2 Catu Listrik 380–500 V AC 35

8.1.3 Catu Listrik 525–600 V (FC 302 saja) 38

8.1.4 Catu Listrik 525–690 V (FC 302 saja) 41

8.2 Catu Listrik 44

8.3 Output Motor dan Data Motor 44

8.4 Kondisi Lingkungan 45

8.5 Spesifikasi Kabel 45

8.6 Kontrol Input/Output dan Data Kontrol 45

8.7 Sekering dan Pemutus Rangkaian 49

8.8 Torsi Pengencangan Sambungan 56

8.9 Rating Daya, Berat, dan Dimensi 57

9 Apendiks 63

9.1 Simbol, Singkatan, dan Konvensi 63

9.2 Struktur Menu Parameter 63

Indeks 73

Daftar Isi VLT® AutomationDrive FC 301/302

2 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

Page 5: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

1 Pendahuluan

1.1 Tujuan Manual

Panduan operasi ini berisi informasi pemasangan dan ujicoba konverter frekuensi secara aman.

Petunjuk operasi ini ditujukan untuk digunakan olehpersonel yang cakap.Baca dan ikuti petunjuk ini untuk dapat menggunakankonverter frekuensi secara aman dan professional,perhatikan secara khusus petunjuk keselamatan danperingatan umum. Simpan panduan operasi ini bersamakonverter.

VLT® adalah merek dagang terdaftar.

1.2 Sumber Tambahan

Sumber lain tersedia untuk memahami fungsi danpemrograman lanjutan konverter frekuensi.

• VLT® AutomationDrive FC 301/FC 302PanduanProgram menyediakan informasi lengkap untukbekerja dengan parameter dan banyak contohaplikasi.

• VLT® AutomationDrive FC 301/FC 302PanduanRancangan berisi penjelasan rinci tentangkemampuan dan fungsi untuk merancang sistemkontrol motor.

• Petunjuk pengoperasian dengan peralatanopsional.

Tambahan informasi publikasi dan manual tersedia dariDanfoss. Lihat www.danfoss.com/en/search/?filter=type%3Adocumentation%2Csegment%3Adds untuk listing.

1.3 Versi Manual dan Perangkat Lunak

Manual ini secara teratur ditinjau dan diperbaharui. Semuasaran untuk perbaikan diterima dengan baik. Tabel 1.1menunjukkan versi manual dan versi perangkat lunak yangbersangkutan.

Edisi Keterangan Versi perangkatlunak

MG33ATxx Koreksi kesalahan. Mengubah

garis tengah kabel ke 10 mm2

(7 AWG)

8.1x, 48.20 (IMC)

Tabel 1.1 Versi Manual dan Perangkat Lunak

1.4 Gambaran Produk

1.4.1 Peruntukan

Konverter frekuensi adalah kontroler motor elektronikuntuk keperluan:

• Mengatur kecepatan motor sebagai respons atasumpan-balik sistem atau perintah jarak jauh darikontroler eksternal. Sistem konverter dayatersusun atas konverter frekuensi, motor, danperalatan yang digerakkan oleh motor.

• Pemonitoran status sistem dan motor.

Konverter frekuensi juga dapat digunakan untuk proteksikelebihan beban pada motor.

Tergantung konfigurasinya, konverter frekuensi dapatdigunakan dalam aplikasi otonom atau sebagai bagian darisistem atau instalasi yang lebih besar.

Konverter frekuensi boleh digunakan di lingkungan industridan komersial sesuai peraturan dan standar lokal.

CATATAN!Di dalam lingkungan perumahan, produk ini dapatmenyebabkan intrferensi radio yang mungkinmembutuhkan langkah mitigasi tambahan.

Potensi penyalah-gunaanJangan gunakan konverter frekuensi dalam aplikasi yangtidak memenuhi kondisi atau lingkungan pengoperasianyang disyaratkan. Pastikan ketentuan di dalam bab 8 Spesifikasidipenuhi.

CATATAN!Frekuensi output konverter frekuensi ini dibatasimaksimal 590 Hz.Untuk kebutuhan di atas 590 Hz, hubungi Danfoss.

Pendahuluan Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 3

1 1

Page 6: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

1.4.2 Gambar Urai

1

2

34

56789

1011

12 13

16171819

146

FAN MOUNTING

QDF-30

DC- DC+

Remove jumper to activate Safe Stop

Max. 24 Volt !12 13 18 19 27 29 32 33 20 37

0605

0403

0201

130B

F713

.10

61 68 69 39 42 50 53 54 55

1

3 5

20

9

6

13

15

14

6

18111016, 17

19

14

7

8

4

2

1 Panel kontrol lokal (LCP) 11 Relai 2 (04, 05, 06)

2 Penutup 12 Ring pengangkat

3 Konektor-fieldbus RS485 13 Slot pemasangan

4 Konektor input/output digital 14 Sambungan pembumi (PE)

5 Konektor input/output digital 15 Konektor pelindung kabel

6 Pembumian dan pelepasan kabel berpelindung 16 Terminal rem (-81, +82)

7 Konektor USB 17 Terminal pembagi beban (-88, +89)

8 Sakelar terminal RS485 18 Terminal motor 96 (U), 97 (V), 98 (W)

9 Sakelar DIP untuk A53 dan A54 19 Terminal input sumber listrik 91 (L1), 92 (L2), 93 (L3)

10 Relai 1 (01, 02, 03) 20 Konektor LCP

Ilustrasi 1.1 Gambar Urai Penutup Ukuran A, IP20 (kiri), dan Penutup Ukuran C, IP55/IP66 (kanan)

Pendahuluan VLT® AutomationDrive FC 301/302

4 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

11

Page 7: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

1.5 Persetujuan dan Sertifikasi Tipe

Daftar berikut adalah pilihan persetujuan dan sertifikasitipe yang mungkin untuk konverter frekuensi Danfoss.

089

CATATAN!Persetujuan dan sertifikasi spesifik untuk konverterfrekuensi Anda ada pada pelat nama konverter frekuensi.Untuk informasi lebih lengkap, hubungi kantor ataumitra Danfoss terdekat.

Untuk informasi selengkapnya tentang ketentuan retensimemori termal UL 508C, lihat bagian Perlindungan TermalMotor di panduan rancangan spesifik produk.

Untuk informasi lebih lanjut tentang kepatuhan terhadapKesepakatan Eropa tentang Transportasi Benda BerbahayaSecara Internasional lewat Perairan Pedalaman (ADN), lihatbagian Pemasangan sesuai ADN di dalam panduanrancangan spesifik.

Pendahuluan Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 5

1 1

Page 8: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

2 Keselamatan

2.1 Simbol Keselamatan

Simbol-simbol berikut digunakan di dalam panduan ini:

PERINGATANMenunjukkan situasi berpotensi membahayakan yangdapat mengakibatkan kematian atau cidera serius.

KEWASPADAANMenunjukkan situasi berpotensi membahayakan yangdapat mengakibatkan cidera ringan atau sedang. Simbolini juga dapat digunakan untuk mengingatkan akanpraktik-praktik yang tidak aman.

CATATAN!Menunjukkan informasi penting, termasuk situasi yangdapat mengakibatkan kerusakan terhadap peralatan atauharta benda.

2.2 Teknisi Yang Cakap

Benar dan pengangkut, penyimpanan, instalasi, operasi,dan pemeliharaan yang baik diperlukan untuk bebasmasalah dan operasi aman dari konverter frekuensi. Hanyapersonal yang berkualifikasi dimungkinkan untukmenginstal dan mengoperasikan peralatan ini.

Teknisi yang cakap adalah staf terlatih, dengan wewenangmenginstal, menguji, serta merawat peralatan, sistem, danrangkaian sesuai undang-undang dan peraturan yangberlaku Di samping itu, personal yang berkualifikasi harusmengetahui petunjuk dan ukuran keselamatan yangdijabarkan dalam manual ini.

2.3 Petunjuk Keselamatan

PERINGATANTEGANGAN TINGGIKonverter mengandung tegangan tinggi saat terhubungke sumber listrik AC, catu daya DC, atau pembagi beban.Pemasangan, penyalaan, dan perawatan konverter selainoleh teknisi yang cakap dapat mengakibatkan kematianatau cidera serius.

• Pemasangan, penyalaan, dan perawatan hanyaboleh dilakukan oleh teknisi yang cakap.

• Sebelum melakukan servis atau perbaikan,gunakan alat pengukur tegangan yang sesuaiuntuk memastikan tidak ada sisa tegangan didalam konverter frekuensi.

PERINGATANSTART TIDAK DISENGAJASaat konverter terhubung ke sumber listrik AC, catu dayaDC, atau pembagi beban, motor dapat menyala kapansaja. Start tanpa sengaja selama pemrograman, servis,atau perbaikan dapat mengakibatkan kematian, cideraserius atau kerusakan harta benda. Motor dapat startmelalui sakelar eksternal, perintah fieldbus, sinyalreference input dari LCP, atau setelah kondisi masalahyang telah selesai.

Untuk mencegah motor menyala tanpa sengaja:• Cabut sambungan kabel konverter dari sumber

listrik.

• Tekan [Off/Reset] pada LCP sebelummemprogram parameter.

• Sambung kabel dan rakit konverter, motor, danperalatan apa pun yang terhubung ke konvertersecara sempurna sebelum menghubungkankonverter ke sumber listrik AC, catu daya DC,atau pembagi beban.

PERINGATANWAKTU PENGOSONGANDi dalam konverter frekuensi ini terdapat kapasitor DC-link, yang tetap berisi arus meski konverter frekuensitidak dialiri daya. Tegangan tinggi mungkin masih adameski lampu indikator LED peringatan sudah mati.Tunggu beberapa saat setelah daya dimatikan sebelummelakukan servis atau perbaikan untuk mencegahkematian atau cidera serius.

• Matikan motor.

• Cabut sumber listrik AC dan catu daya DC link,termasuk baterai cadangan, UPS, dan koneksiDC-link ke konverter frekuensi lain.

• Matikan daya atau kunci motor PM.

• Tunggu sampai kapasitor kosong sepenuhnya.Durasi minimum waktu tunggu disebutkandalam Tabel 2.1 dan juga dapat dilihat padapelat nama produk di bagian atas konverterfrekuensi.

• Sebelum melakukan servis atau perbaikan,gunakan alat pengukur tegangan yang sesuaiuntuk memastikan kapasitor sudah benar-benarkosong.

Keselamatan VLT® AutomationDrive FC 301/302

6 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

22

Page 9: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

TeganganListrik (V)

Tunggu sedikitnya (menit)

4 7 15

200–240 0.25–3.7 kW(0.34–5 hp)

– 5.5–37 kW(7.5–50 hp)

380–500 0.25–7.5 kW(0.34–10 hp)

– 11–75 kW(15–100 hp)

525–600 0.75–7.5 kW(1–10 hp)

– 11–75 kW(15–100 hp)

525–690 – 1.5–7.5 kW(2–10 hp)

11–75 kW(15–100 hp)

Tabel 2.1 Waktu pengosongan

PERINGATANBAHAYA KEBOCORAN ARUSKebocoran arus melebihi 3,5 mA. Bumikan konverterfrekuensi dengan sempurna untuk mencegah risikokematian atau cidera serius.

• Pastikan konverter telah dibumikan dengansempurna oleh instalatur listrik resmi.

PERINGATANRISIKO PERALATANKontak dengan poros yang berputar dan peralatan listrikdapat mengakibatkan kematian atau cidera serius.

• Pastikan bahwa hanya pekerja yang telah dilatihmelakukan instalasi, memulai dan perawatan.

• Pastikan sambungan listrik memenuhi peraturankelistrikan nasional dan lokal.

• Ikuti prosedur di dalam panduan ini.

PERINGATANPUTARAN MOTOR TANPA SENGAJAMENGINCIRMotor magnet permanen yang berputar tanpa sengajadapat menghasilkan voltase dan mengalirkan daya keunit, mengakibatkan kematian, cidera serius, dankerusakan peralatan.

• Jangan lupa mengganjal motor bermagnetpermanen untuk mencegahnya berputar tanpasengaja.

KEWASPADAANBAHAYA KEGAGALAN KOMPONEN BAGIANDALAMKegagalan komponen internal konverter frekuensi dapatmengakibatkan cidera serius saat frekuensi konvertertidak ditutup dengan sempurna.

• Sebelum mengalirkan daya, pastikan semuapelindung keamanan terpasang dan mantap.

Keselamatan Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 7

2 2

Page 10: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

3 Instalasi Mekanis

3.1 Membuka kemasan

3.1.1 Item Yang Disertakan

Item dipasok berubah menurut konfigurasi produk.

• Pastikan item yang disertakan dan informasi padapelat nama sesuai dengan urutan konfirmasi.

• Periksa kemasan dan konverter frekuensi apakahmengalami kerusakan akibat penanganan yangtidak sesuai selama pengiriman. Ajukan klaimkerusakan apa pun terhadap jasa pengiriman.Simpan komponen yang rusak untuk klarifikasi.

130B

D60

0.11

CHASSIS/ IP20 Tamb.50 C/122 F

VLT

MADE IN DENMARK

R

P/N: 131X3537 S/N: 010122G430

0.37kW/ 0.50HP

IN: 3x200-240V 50/60Hz 2.2A

OUT: 3x0-Vin 0-590Hz 2.4Ao

CAUTION:See manual for special condition/mains fuseVoir manual de conditions speclales/fusibles

WARNING:Stored charge, wait 4 min.Charge residuelle, attendez 4 min.

* 1 3 1 X 3 5 3 7 0 1 0 1 2 2 G 4 3 0 *

`

Automation Drivewww.danfoss.com

T/C: FC-302PK37T2E20H1BGXXXXSXXXXA6BKC4XXXD0

Listed 76X1 E134261 Ind. Contr. Eq.

o

`

1

2

4

5

6

7 8

9

10

3

1 Kode jenis

2 Nomor kode

3 Nomor Seri

4 Rating daya

5Voltase, frekuensi, dan arus input (pada voltase rendah/tinggi)

6Voltase, frekuensi, dan arus output (pada voltase rendah/tinggi)

7 Ukuran penutup dan rating IP

8 Suhu lingkungan maksimum

9 Sertifikasi

10 Waktu Pengosongan (Peringatan)

Ilustrasi 3.1 Pelat Nama Produk (Contoh)

CATATAN!Jangan mencopot pelat nama dari konverter frekuensi(menghanguskan garansi).

Pastikan syarat penyimpanan terpenuhi. Lihat bab 8.4 Kondisi Lingkungan untuk rincian lebih lanjut.

3.2 Lingkungan Pemasangan

CATATAN!Di lingkungan dengan udara yang banyak mengandungcairan, partikel, atau gas korosif, pastikan rating IP/Tipeperalatan cocok untuk lingkungan pemasangannya.Mengabaikan syarat lingkungan dapat memperpendekumur pemakaian konverter frekuensi. Pastikan syaratkelembapan udara, suhu, dan ketinggian dipenuhi.

Getaran dan kejutanKonverter frekuensi ini memenuhi persyaratan untukdipasang pada dinding dan lantai pabrik, dan pada panelyang dibaut ke dinding atau lantai.

Untuk spesifikasi rinci kondisi lingkungan, lihat bab 8.4 Kondisi Lingkungan.

3.3 Pemasangan

CATATAN!Kesalahan pemasangan dapat mengakibatkan panasberlebihan dan menurunkan kinerja.

Pendinginan

• Pastikan tersedia ruang yang cukup antara bagianatas dan bawah untuk mendinginkan udara.LihatIlustrasi 3.2 untuk syarat ruang bebas.

a

a

130B

D52

8.10

Ilustrasi 3.2 Ruang Bebas Pendinginan Atas dan Bawah

Instalasi Mekanis VLT® AutomationDrive FC 301/302

8 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

33

Page 11: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Penutup A1–A5 B1–B4 C1, C3 C2, C4

a [mm (in)] 100 (3.9) 200 (7.8) 200 (7.8) 225 (8.9)

Tabel 3.1 Persyaratan Ruang Bebas Minimum Untuk Aliran Udara

Mengangkat• Pastikan perangkat pengangkat sesuai untuk

tugas tersebut.

• Apabila diperlukan, siapkan kerekan, keran, atauforklift dengan rating yang sesuai untukmemindahkan unit.

• Untuk mengangkat, gunakan ring kerek padaunit, jika ada.

PERINGATANBEBAN BERATBeban yang tidak seimbang dapat jatuh dan terbalik.Ikuti petunjuk pengangkatan yang ditentukan untukmeminimalkan risiko kematian, cidera berat, ataukerusakan peralatan.

• Jangan sekali-sekali berjalan di atas bebanmenggantung.

• Untuk mencegah cidera, gunakan peralatanpelindung pribadi seperti sarung tangan, kacamata pengaman, dan sepatu keselamatan.

• Hanya gunakan alat angkat dengan ratingbeban yang sesuai. Untuk menentukan metodepengangkatan yang aman, perhatikan bobotunit, lihatbab 8.9 Rating Daya, Berat, danDimensi.

• Sudut dari bagian tas modul drive terhadapkabel pengangkat memengaruhi gaya bebanmaksimum terhadap kabel. Sudut ini wajib 65°atau lebih besar. Pasang dan ukur dimensikabel pengangkat dengan benar.

Pemasangan1. Pastikan kekuatan lokasi pemasangan

mendukung berat unit. Konverter frekuensi dapatdipasang berdampingan.

2. Tempatkan unit sedekat mungkin dengan motor.Gunakan kabel motor sependek mungkin.

3. Pasang unit secara vertikal di atas permukaanrata atau pelat belakang opsional untuk mengha-silkan aliran udara pendingin.

4. Gunakan lubang pemasangan berslot pada unituntuk pemasangan di dinding, jika ada.

Pemasangan dengan pemasangan pelat dan teralis.Untuk pemasangan pada teralis, dibutuhkan pelatpemasangan.

130B

D50

4.10

Ilustrasi 3.3 Cara Benar Melakukan Pemasangan dengan PelatPemasangan

Instalasi Mekanis Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 9

3 3

Page 12: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

4 Instalasi Kelistrikan

4.1 Petunjuk Keselamatan

Lihat bab 2 Keselamatanuntuk petunjuk keselamatanumum.

PERINGATANVOLTASE INDUKSIVoltase induksi dari kabel motor output yangbersentuhan dapat mengalirkan arus ke kapasitorperalatan, meski peralatan dimatikan dan dikunci. Tidakmemasang kabel motor output secara terpisah ataumenggunakan kabel berpelindung dapat mengakibatkankematian atau cidera serius.

• Pasang kabel motor output secara terpisah,atau

• Gunakan kabel berpelindung.

KEWASPADAANBAHAYA TERSENGAT LISTRIKKonverter frekuensi dapat menghasilkan arus DC didalam konduktor PE. Jika ketentuan ini tidak dipatuhi,RCD tidak dapat memberikan perlindungan yangdibutuhkan.

• Jika perangkat pelindung berbasis arus residu(RCD) digunakan sebagai perlindungan atassengatan listrik, hanya RCD Tipe B yangdibolehkan pada sisi catu.

Perlindungan dari kelebihan arus• Untuk aplikasi dengan beberapa motor,

dibutuhkan peralatan perlindungan tambahanseperti proteksi arus pendek atau proteksi termalmotor antara konverter frekuensi dan motor.

• Sekering input diperlukan untuk menyediakanperlindugan terhadap arus pendek dan kelebihanarus. Jika sekering tidak disertakan dari pabrik,instalatur bertanggung jawab menyediakannya.Untuk rating sekering maksimum, lihat bab 8.7 Sekering dan Pemutus Rangkaian.

Tipe dan rating kabel• Semua perkabelan wajib mematuhi peraturan

lokal dan nasional tentang diameter dan suhulingkungan.

• Rekomendasi kabel sambungan daya: Kawattembaga dengan rating minimum 75 °C (167 °F).

Lihat bab 8.1 Data Kelistrikan dan bab 8.5 Spesifikasi Kabeluntuk ukuran dan jenis kabel yang direkomendasikan.

4.2 EMC-sesuai Instalasi

Untuk melakukan instalasi sesuai EMC, ikuti petunjuk yangdiberikan dalambab 4.3 Arde, bab 4.4 Skematis Kabel, bab 4.5 Sambungan Motor, danbab 4.7 Kabel Kontrol.

4.3 Arde

PERINGATANBAHAYA KEBOCORAN ARUSKebocoran arus melebihi 3,5 mA. Bumikan konverterfrekuensi dengan sempurna untuk mencegah risikokematian atau cidera serius.

• Pastikan konverter telah dibumikan dengansempurna oleh instalatur listrik resmi.

Untuk keselamatan listrik• Bumikan konverter frekuensi sesuai standar dan

ketentuan yang berlaku.

• Gunakan kabel pembumi khusus untukperkawatan daya input, daya motor, dan kontrol.

• Jangan bumikan 1 konverter frekuensi kekonverter frekuensi lain secara seri(lihatIlustrasi 4.1).

• Koneksi kabel pembumi harus sependekmungkin.

• Ikuti ketentuan perkawatan pabrikan motor.

• Diameter minimum kabel pembumi: 10 mm2 (7AWG).

• Terminasi masing-masing kabel pembumiansecara terpisah, berdasarkan ketentuan dimensi.

Instalasi Kelistrikan VLT® AutomationDrive FC 301/302

10 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

44

Page 13: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

130B

C500

.10

FC 1

FC 1

FC 2

FC 2

FC 3

FC 3

PE

PE

Ilustrasi 4.1 Prinsip Pembumian

Untuk Pemasangan Sesuai EMC• Jalin kontak elektrik antara pelindung kabel dan

penutup konverter frekuensi menggunakankonektor kabel logam atau klem yang disediakanpada peralatan (lihatbab 4.5 Sambungan Motor).

• Gunakan kabel serat tinggi untuk mengurangiletupan osilasi.

• Jangan gunakan ekor babi.

CATATAN!PENYEIMBANGAN POTENSIAda risiko terjadi letupan osilasi saat potensi pembumiantara konverter frekuensi dan sistem kontrol berbeda.Pasang kabel penyeimbang antara komponen sistem.Diameter kabel yang disarankan: 16 mm2 (6 AWG).

Instalasi Kelistrikan Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 11

4 4

Page 14: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

4.4 Skematis Kabel

130B

D59

9.11

3-phase

power

input

DC bus Switch ModePower Supply

Motor

Analog Output

Interface

relay1

relay21)

ON=TerminatedOFF=Open

Brakeresistor

91 (L1)92 (L2)93 (L3)

PE

88 (-)89 (+)

50 (+10 V OUT)

53 (A IN)

54 (A IN)

55 (COM A IN)0/4–20 mA

12 (+24 V OUT)

13 (+24 V OUT)

37 (D IN)1)

18 (D IN)

20 (COM D IN)

10 V DC15 mA 130/200 mA

+ - + -

(U) 96(V) 97(W) 98(PE) 99

(COM A OUT) 39

(A OUT) 42

(P RS485) 68

(N RS485) 69

(COM RS485) 612)

0 V

5V

S801

0/4–20 mA

RS-485RS485

03

+10 V DC0/-10 V DC–

+10 V DC

+10 V DC0/4–20 mA

0/-10 V DC–

240 V AC, 2 A

24 V DC

02

01

05

04

06

24 V (NPN) 0 V (PNP)

0 V (PNP)24 V (NPN)

19 (D IN)

24 V (NPN) 0 V (PNP)27

24 V

0 V

(D IN/OUT)

0 V (PNP)24 V (NPN)

(D IN/OUT)1)

0 V

24 V29

24 V (NPN) 0 V (PNP)

0 V (PNP)24 V (NPN)

33 (D IN)

32 (D IN)

12

ON

S201

ON2

1S202ON=0/4–20 mAOFF=0/-10 V DC– +10 V DC

95

P 5-00

21 O

N

S801

(R+) 82

(R-) 81

: Chassis

240 V AC, 2 A

400 V AC, 2 A

: Ground

: Ground 1

: Ground 2

: PE

Ilustrasi 4.2 Skematis Kabel Dasar

A=Analog, D=Digital1) Terminal 37 (opsional) digunakan untuk Safe Torque Off (STO). Untuk petunjuk pemasangan, lihat VLT® Petunjuk Pengope-rasian Safe Torque Off. Untuk FC 301, terminal 37 hanya disertakan bersama penutup ukuran A1. Relai 2 dan terminal 29tidak mempunyai fungsi dalamFC 301.2) Jangan sambung pelindung kabel.

Instalasi Kelistrikan VLT® AutomationDrive FC 301/302

12 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

44

Page 15: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

e30b

f228

.11

L1L2L3PE

PE

u

v

w

2

1

3

5

16

17

18

14

12

8

7

10

9

4

11

13

4

6

15

90

4

1 PLC. 10 Kabel sumber listrik (tanpa pelindung).

2 Kabel penyeimbang minimum 16 mm2 (6 AWG) 11 Kontaktor output

3 Kabel kontrol. 12 Kabel insulasi dikupas.

4 Minimum 200 mm (7,9 in) antara kabel kontrol, kabel motor,dan kabel sumber listrik.

13 Busbar pembumi bersama. Patuhi peraturan setempat dannasional tentang pembumian kabinet.

5 Catu listrik. 14 Resistor rem.

6 Permukaan polos (tanpa cat). 15 Kotak logam.

7 Cincin bintang. 16 Sambungan ke motor

8 Kabel rem (berpelindung). 17 Motor.

9 Kabel motor (berpelindung).. 18 Konektor kabel EMC.

Ilustrasi 4.3 Contoh Cara Benar Memasang EMC

Instalasi Kelistrikan Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 13

4 4

Page 16: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Untuk informasi selengkapnya tentang EMC, lihat bab 4.2 EMC-sesuai Instalasi

CATATAN!INTERFERENSI EMCGunakan kabel berpelindung untuk sambungan motordan kontrol, dan kabel tersendiri untuk input daya,motor, dan kontrol. Tidak menginsulasi kabel daya,motor, dan kontrol dapat mengakibatkan perilaku yangtidak diinginkan atau menurunkan performa. Sediakanruang bebas minimum 200 mm (7,9 in) antara kabelinput daya, motor, dan kontrol.

4.5 Sambungan Motor

PERINGATANVOLTASE INDUKSIVoltase induksi dari kabel motor output yangbersentuhan dapat mengalirkan arus ke kapasitorperalatan, meski peralatan dimatikan dan dikunci. Tidakmemasang kabel motor output secara terpisah ataumenggunakan kabel berpelindung dapat mengakibatkankematian atau cidera serius.

• Pasang kabel motor output secara terpisah, atau

• Gunakan kabel berpelindung.

• Patuhi peraturan kelistrikan setempat dannasional tentang ukuran kabel. Untuk ukurankawat maksimum, lihat bab 8.1 Data Kelistrikan.

• Ikuti ketentuan perkawatan pabrikan motor.

• Panel akses ke perkabelan motor ada di pijakanunit IP21 (NEMA1/12) ke atas.

• Jangan menyambung kabel ke papan start ataupengalih kontak (misalnya motor Dahlander ataumotor asinkron cincin selip) antara konverterfrekuensi dan motor.

Prosedur membumikan pelindung kabel

1. Kupas sedikit insulasi luar kabel.

2. Perkuat patok mekanik dan kontak elektrik antarapelindung kabel dan pembumi denganmemosisikan kabel kupasan di bawah penjepitkabel.

3. Sambung kabel arde ke terminal arde terdekatmenurut petunjuk arde yang disediakandibab 4.3 Arde, lihat Ilustrasi 4.4.

4. Hubungkan kabel motor 3 fase ke terminal 96 (U),97 (V), dan 98 (W), lihat Ilustrasi 4.4.

5. Kencangkan terminal menurut informasi yangdisediakan di bab 8.8 Torsi PengencanganSambungan.

130B

D53

1.10

UV

W

9697

98

Ilustrasi 4.4 Sambungan Motor

Ilustrasi 4.5 menunjukkan input sumber listrik, motor, danarde untuk konverter frekuensi dasar. Konfigurasi dilapangan bervariasi menurut tipe dan peralatan opsional.

Instalasi Kelistrikan VLT® AutomationDrive FC 301/302

14 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

44

Page 17: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

+DC BR- B

MA

I NS

L1 L2 L391 92 93

RELA

Y 1

RE

LAY

2

99 U V W

MOTOR

99

130B

F048

.11

Ilustrasi 4.5 Contoh Sambungan Kabel Motor, Sumber Listrik,dan Arde

4.6 Sambungan Sumber Listrik AC

• Pilih ukuran kabel sesuai arus input konverterfrekuensi. Untuk ukuran kawat maksimum, lihat bab 8.1 Data Kelistrikan.

• Patuhi peraturan kelistrikan setempat dannasional tentang ukuran kabel.

Prosedur1. Hubungkan kabel daya input AC 3 fase ke

terminal L1, L2, dan L3 (lihatIlustrasi 4.5).

2. Tergantung konfigurasi peralatan, sambungkandaya input ke terminal input sumber listrik ataupemutus input.

3. Bumikan kabel sesuai informasi pembumian yangdisediakan dalambab 4.3 Arde.

4. Jika daya diperoleh dari sumber listrik terisolasi(sumber listrik IT atau floating delta) atau sumberlistrik TT/TN-S dengan kaki dibumikan (groundeddelta), pastikan diaturparameter 14-50 Filter RFI ke[0] Off. Pengaturan ini mencegah DC-linkmengalami kerusakan dan mengurangi aruskapasitas pembumi sesuai ketentuan IEC 61800-3.

4.7 Kabel Kontrol

• Pisahkan kabel kontrol dari kabel komponenberkekuatan tinggi di dalam konverter frekuensi.

• Saat konverter frekuensi terhubung ke termistor,pastikan termistor menggunakan kabel kontrolberpelindung dan berinsulasi ganda. Disarankanmenggunakan voltase catu daya 24 V DC.

4.7.1 Safe Torque Off (STO)

4.7.2 Kontrol Rem Mekanis

Dalam aplikasi pengangkatan/penurunan, diperlukanpengontrolan rem elektro-mekanis.

• Kontrol rem dengan output relai atau outputdigital (terminal 27 atau 29).

• Tutup output (tanpa voltase) selama mungkin jikakonverter frekuensi tidak dapat mempertahankanmotor dalam posisi diam, misalnya karena bebanterlalu berat.

• Pilih kontrol rem Mekanis [32] di Relai grupparameter 5-4* untuk aplikasi dengan rem elektro-magnetik.

• Rem dilepas bila arus motor melebihi nilai dalamparameter 2-20 Arus pelepas Brake.

• Rem bekerja bila frekuensi output lebih kecildaripada frekuensi yang diatur padaparameter 2-21 Aktifkan Kecepatan Brake/Rem[RPM] atau parameter 2-22 MengaktifkanKecepatan Brake [Hz], dan hanya jika konverterfrekuensi sedang melaksanakan perintah berhenti.

Jika konverter frekuensi berada dalam modus alarm ataudalam situasi kelebihan tegangan, rem mekanis langsungberhenti.

CATATAN!Konverter frekuensi bukan alat pengaman. Perancangsistem bertanggung jawab mengintegrasikan perangkatkeselamatan berdasarkan peraturan nasional yangberlaku tentang keran/alat angkat.

Instalasi Kelistrikan Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 15

4 4

Page 18: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

130B

A90

2.10

L1 L2 L3

U V W

02 01

A1

A2

Frequency converterOutput

relay

Command circuit220 V AC

Mechanicalbrake

ShaftMotor

Freewheelingdiode

Brake380 V AC

Outputcontactorinput

power circuit

Ilustrasi 4.6 Menghubungkan Rem Mekanik ke KonverterFrekuensi

4.8 Daftar Periksa Instalasi

Sebelum menyelesaikan pemasangan unit, periksa seluruh instalasi seperti dijelaskan dalam Tabel 4.1. Periksa dan tandaiitem setelah selesai.

Periksa Keterangan ☑Peralatan tambahan • Cari peralatan tambahan, sakelar, pemutus, atau sekering input/pemutus rangkaian pada sisi daya input

atau sisi output konverter frekuensi ke motor. Pastikan semua komponen ini siap untuk beroperasi padakecepatan penuh.

• Periksa fungsi dan pemasangan sensor umpan-balik ke konverter frekuensi.

• Lepas batasan koreksi faktor daya apa pun pada motor.

• Sesuaikan batas koreksi faktor daya pada sisi sumber listrik dan pastikan komponen diinsulasi.

Perutean kabel • Pastikan sambungan motor dan kabel kontrol menggunakan kabel terpisah atau terlindung, atauberbentuk 3 konduit logam terpisah untuk mengisolasi interferensi frekuensi tinggi.

Kabel kontrol • Periksa apakah ada kabel yang putus atau rusak dan koneksi longgar.

• Pastikan kabel kontrol terisolasi dari kabel daya tinggi untuk meminimalkan gangguan.

• Periksa sumber voltase sinyal, jika perlu.

Penggunaan kabel berpelindung atau pasangan berpilin direkomendasikan. Pastikan pelindung diterminasidengan benar.

Ruang bebas untukpendinginan

• Pastikan tersedia ruang yang cukup antara bagian atas dan bawah untuk mengalirkan udara pendingin,lihat bab 3.3.1 Pemasangan.

Kondisi lingkungan • Pastikan persyaratan kondisi lingkungan terpenuhi.

Sekering danpemutus rangkaian

• Periksa apakah sekering atau pemutus rangkaian bekerja dengan benar.

• Pastikan semua sekering terpasang dengan benar dan bekerja normal serta semua pemutus rangkaian(jika ada) dalam posisi terbuka.

Pembumi • Pastikan sambungan pembumi cukup dan kedap serta bebas dari oksidasi.

• Jangan menggunakan konduit sebagai pembumi atau memasang panel belakang ke permukaan logam.

Instalasi Kelistrikan VLT® AutomationDrive FC 301/302

16 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

44

Page 19: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Periksa Keterangan ☑Kabel daya inputdan output

• Periksa adakah sambungan yang longgar.

• Pastikan motor dan sumber listrik menggunakan konduit berbeda atau kabel berpelindung tersendiri.

Interior panel • Pastikan bagian dalam unit bersih dari kotoran, serpihan logam, embun, dan karat.

• Pastikan unit dipasang pada permukaan logam tanpa cat.

Sakelar • Pastikan semua pengaturan sakelarr dan pemutus sudah dalam posisi yang benar.

Getaran • Pastikan unit terpasang mantap, atau peredam kejutan sudah terpasang, jika perlu.

• Periksa apakah terjadi getaran berlebihan.

Tabel 4.1 Daftar Periksa Instalasi

KEWASPADAANPOTENSI BAHAYA JIKA TERJADI KEGAGALAN INTERNALKonverter frekuensi yang tidak ditutup dengan benar dapat mengakibatkan cidera badan.

• Sebelum mengalirkan daya, pastikan semua pelindung keamanan terpasang dan mantap.

Instalasi Kelistrikan Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 17

4 4

Page 20: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

5 Uji Coba

5.1 Petunjuk Keselamatan

Lihat bab 2 Keselamatanuntuk petunjuk keselamatanumum.

PERINGATANTEGANGAN TINGGIKonverter frekuensi mengandung tegangan tinggi saatterhubung ke daya input dari sumber listrik AC.Pemasangan, penyalaan, dan perawatan konverter selainoleh teknisi yang cakap dapat mengakibatkan kematianatau cidera serius.

• Pemasangan, penyalaan, dan perawatankonverter hanya boleh dilakukan oleh teknisiyang cakap.

CATATAN!Penutup depan dengan tanda peringatan adalahkomponen terintegrasi konverter frekuensi dan dianggapsebagai tutup pengaman. Penutup wajib terpasangdengan benar sebelum daya dialirkan dan sepanjangwaktu.

Sebelum mengalirkan daya:1. Pasang tutup pengaman dengan benar.

2. Pastikan semua konektor kabel dikencangkansempurna.

3. Pastikan daya input ke unit dalam posisi OFF dandikunci. Jangan mengandalkan sakelar pemutuskonverter frekuensi untuk mengisolasi daya input.

4. Pastikan tidak ada voltase pada terminal input L1(91), L2 (92), and L3 (93), fasa-ke-fasa, dan fasa-ke-pembumi.

5. Pastikan tidak ada voltase pada terminal output96 (U), 97 (V), and 98 (W), fasa-ke-fasa, dan fasa-ke-pembumi.

6. Pastikan kontinitas motor dengan mengukurnilaiΩ pada U–V (96–97), V–W (97–98), and W–U(98–96).

7. Pastikan konverter frekuensi dan motor sudahdibumikan dengan benar.

8. Periksa sambungan terminal pada konverterfrekuensi apakah longgar.

9. Pastikan voltase catu sesuai dengan voltasekonverter frekuensi dan motor.

Uji Coba VLT® AutomationDrive FC 301/302

18 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

55

Page 21: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

5.2 Operasi Panel Kontrol Lokal

130B

F714

.10

AutoOn

ResetHandOn

O�

Status QuickMenu

MainMenu

AlarmLog

BackCancel

InfoOK

Status 1(1)36.4 kW

Auto Remote Ramping

0.000

On

Alarm

Warn.

7.83 A799 RPM

53.2 %

1

2

316

17

4

15

14

13

12

5

6

7

8 9 10 11

Tombol Fungsi

1 Informasi yang ditampilkan pada area tampilan ditentukan oleh fungsi atau menu yang dipilih (di sini Menu CepatQ3-13 Pengaturan Tampilan).

2 Status Menampilkan informasi pengoperasian.

3 Menu Cepat Membolehkan akses ke parameter untuk petunjuk pengaturan awal dan berbagai petunjuk aplikasi terperinci.

4 Kembali Kembali pada langkah atau daftar sebelumnya di struktur menu.

5 Lampu indikatorhijau.

Daya aktif.

6 Lampu indikatorkuning.

Lampu indikator menyala saat peringatan aktif. Teks muncul pada area tampilan berisi penjelasan masalah.

7 Lampu indikatormerah.

Kondisi bermasalah menyebabkan lampu indikator berkedip dan menampilkan teks alarm.

8 [Hand On] Mengubah status konverter frekuensi ke mode kontrol lokal, sehingga sama dengan LCP.

• Sinyal berhenti eksternal oleh input kontrol atau komunikasi serial membatalkan lokal [Hand On].

9 Mati Mematikan motor tetapi tidak memutus daya ke konverter frekuensi.

10 [Auto On] Mengaktifkan mode pengoperasian jarak jauh pada sistem.

• Merespon perintah eksternal untuk mulai dari terminal kontrol atau komunikasi seri.

11 Reset Mereset konverter frekuensi secara manual setelah masalah teratasi.

12 OK Tekan untuk mengakses grup parameter atau mengaktifkan pilihan.

13 Tombol Navigasi Gunakan tombol navigasi untuk beralih antar item di dalam menu.

14 Info Tekan untuk melihat penjelasan untuk fungsi yang sedang ditampilkan.

15 Batal Membatalkan perubahan atau perintah terakhir selama modus tampilan tidak berubah.

16 Menu Utama Membolehkan akses ke semua parameter pemrograman.

17 Log Alarm Menampilkan daftar peringatan terkini, 10 alarm terakhir, serta log perawatan.

Ilustrasi 5.1 Panel Kontrol Lokal Grafis (GLCP)

Uji Coba Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 19

5 5

Page 22: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

5.3 Persiapan Sistem

1. Jalankan Adaptasi Motor Otomatis (AMA):

1a Atur parameter motor dasar berikut seperti ditampilkan dalam Tabel 5.1sebelum menjalankan AMA.

1b Optimalkan kompatibilitas antara motor dan konverter frekuensi via parameter 1-29 Penyesuaian MotorOtomatis (AMA).

2. Periksa rotasi motor.

3. Jika menggunakan umpan-balik enkoder, lakukan beberapa langkah berikut:

3a Pilih [0] Kec. rangk. terbuka dalam parameter 1-00 Mode Konfigurasi.

3b Pilih [1] encoder 24V dalam parameter 7-00 PID Kecepatan Sumber Umpan Balik.

3c Tekan [Hand On]

3d Tekan [►] untuk referensi kecepatan positif (parameter 1-06 Searah Jarum Jam di [0]* Normal).

3e Pada parameter 16-57 Feedback [RPM], pastikan umpan balik positif.

Parameter 1-10 Konstruksi Motor

ASM PM SynRM

Parameter 1-20 Daya Motor [kW]Parameter 1-21 Daya motor [HP]

X

Parameter 1-22 Tegangan Motor X

Parameter 1-23 Frekuensi Motor X X

Parameter 1-24 Arus Motor X X X

Parameter 1-25 Kecepatan Nominal Motor X X X

Parameter 1-26 Torsi Terukur Kontrol Motor X X

Parameter 1-39 Kutub Motor X

Tabel 5.1 Parameter dasar yang perlu diperiksa sebelum AMA

Uji Coba VLT® AutomationDrive FC 301/302

20 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

55

Page 23: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

6 Konfigurasi I/O Dasar

Contoh di bagian ini dimaksudkan sebagai referensi cepatuntuk aplikasi umum.

• Pengaturan parameter adalah nilai standarregional kecuali dinyatakan lain (dipilih diparameter 0-03 Pengaturan Wilayah).

• Parameter yang berhubungan dengan terminaldan pengaturannya ditampilkan di sebelahgambar.

• Pengaturan sakelar yang disyaratkan untukterminal analog A53 atau A54 juga ditampilkan.

CATATAN!Saat fitur Safe Torque Off (STO) opsional digunakan,dibutuhkan kabel jumper antara terminal 12 (atau 13)dan terminal 37 untuk mengoperasikan konverterfrekuensi menggunakan nilai pemrograman standarpabrik.

6.1 Contoh Aplikasi

6.1.1 Termistor Motor

KEWASPADAANINSULASI TERMISTORRisiko cidera badan atau kerusakan peralatan.

• Untuk memenuhi persyaratan insulasi PELV,gunakan termistor dengan insulasi berpenguatatau ganda saja.

Parameter

130B

B686

.12

VLT

+24 V

+24 V

D IN

D IN

D IN

COM

D IN

D IN

D IN

+10 VA IN

A IN

COM

A OUT

COM

12

13

18

19

20

27

29

32

33

50

53

54

55

42

39

A53

U - I

D IN 37

Fungsi Pengaturan

Parameter 1-90 Proteksi pdtermal motor

[2] Termistoranjlok

Parameter 1-93 SumberThermistor

[1] Inputanalog 53

* = Nilai standar

Catatan/komentar:Jika hanya peringatan yangdiinginkan, aturparameter 1-90 Proteksi pdtermal motor ke [1] Peringatantermistor.D DI 37 adalah sebuah opsi.

Tabel 6.1 Termistor Motor

Konfigurasi I/O Dasar Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 21

6 6

Page 24: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

6.1.2 Kontrol Rem Mekanis

Parameter

FC

+24 V

+24 V

D IN

D IN

D IN

COM

D IN

D IN

D IN

D IN

+10 V

A IN

A IN

COM

A OUT

COM

R1R2

12

13

18

19

20

27

29

32

33

37

50

53

54

55

42

39

01

02

03

04

05

06

130B

B841

.10 Fungsi Pengaturan

Parameter 5-40 Relai Fungsi

[32] Kontr. remmekanik

Parameter 5-10 Terminal 18Input Digital

[8] Start*

Parameter 5-11 Terminal 19Input Digital

[11] Startpembalikan

Parameter 1-71 Penundaanstart

0.2

Parameter 1-72 Fungsi start

[5] VVC+/FLUXSearah jarumjam

Parameter 1-76 Arus Start

Im,n

Parameter 2-20 Arus pelepasBrake

Tergantungaplikasi

Parameter 2-21 AktifkanKecepatanBrake/Rem[RPM]

Setengah slipnominal motor

*=Nilai Standar

Catatan/komentar:–

Tabel 6.2 Kontrol Rem Mekanis

Start (18)

Start reversing (19)

Relay output

Speed

Time

Current

1-71 1-712-21 2-21

1-76

OpenClosed

130B

B842

.10

Ilustrasi 6.1 Kontrol Rem Mekanis

Konfigurasi I/O Dasar VLT® AutomationDrive FC 301/302

22 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

66

Page 25: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

7 Pemeliharaan, Diagnostik, dan Pemecahan Masalah

7.1 Perawatan dan Servis

Dalam kondisi pengoperasian dan profil beban normal,konverter tidak membutuhkan perawatan selama masapakai yang ditentukan. Untuk mencegah kerusakan,bahaya, dan kerusakan, periksa konverter secara teraturapakah sambungan terminal masih kencang, apakah adakotoran masuk, dan lain sebagainya tergantung kondisipengoperasian. Ganti komponen yang aus atau rusakdengan suku cadang asli atau standar. Untuk layanan dandukungan, hubungi pemasok Danfoss lokal.

PERINGATANSTART TIDAK DISENGAJASaat konverter terhubung ke sumber listrik AC, catu dayaDC, atau pembagi beban, motor dapat menyala kapansaja. Start tanpa sengaja selama pemrograman, servis,atau perbaikan dapat mengakibatkan kematian, cideraserius atau kerusakan harta benda. Motor dapat startmelalui sakelar eksternal, perintah fieldbus, sinyalreference input dari LCP, atau setelah kondisi masalahyang telah selesai.

Untuk mencegah motor menyala tanpa sengaja:• Cabut sambungan kabel konverter dari sumber

listrik.

• Tekan [Off/Reset] pada LCP sebelummemprogram parameter.

• Sambung kabel dan rakit konverter, motor, danperalatan apa pun yang terhubung ke konvertersecara sempurna sebelum menghubungkankonverter ke sumber listrik AC, catu daya DC,atau pembagi beban.

7.2 Jenis Peringatan dan Alarm

PeringatanPeringatan muncul jika terjadi kondisi yang berpotensimemicu alarm atau kondisi pengoperasian abnormal yangdapat memicu konverter frekuensi mengeluarkan alarm.Peringatan berhenti sendiri setelah abnormalitas kondisiteratasi.

AlarmAlarm menandakan adanya masalah yang perlu segeramendapat perhatian. Masalah ini memicu konverter tripatau terkunci mati. Reset sistem setelah terjadi alarm.

TripAlarm muncul saat konverter frekuensi trip, yaitu, konverterfrekuensi berhenti beroperasi untuk mencegah terjadinyakerusakan pada dirinya sendiri maupun pada sistem. Motormelambat kemudian berhenti. Logik konverter terusberoperasi dan memonitor status konverter frekuensi.

Setelah masalah teratasi, konverter frekuensi dapat direset.Konverter frekuensi siap dioperasikan kembali.

Mereset konverter frekuensi setelah anjlok/terkuncianjlok

Konverter frekuensi dapat direset dengan salah satu dari 4cara berikut:

• Tekan [Reset] pada LCP.

• Perintah input reset digital.

• Perintah input reset komunikasi seri.

• Reset otomatis.

Kunci tripDaya input dimatikan lalu dialirkan kembali. Motormelambat kemudian berhenti. Konverter frekuensi terusmemonitor status konverter frekuensi. Matikan daya kekonverter frekuensi, perbaiki penyebab masalah, lalu resetkonverter frekuensi.

Tampilan peringatan dan alarm

• Sebuah peringatan ditampilkan pada LCPbersama nomornya.

• Alarm berkedip bersama nomornya.

130B

P086

.12

Status0.0Hz 0.000kW 0.00A

0.0Hz0

Earth Fault [A14]Auto Remote Trip

1(1)

Ilustrasi 7.1 Contoh Alarm

Selain teks dan kode alarm pada LCP, ada 3 lampuindikator status.

Pemeliharaan, Diagnostik, d... Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 23

7 7

Page 26: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Back

CancelInfoOKOn

Alarm

Warn.

130B

B467

.11

Lampu indikatorperingatan

Lampu indikator alarm

Peringatan Nyala Mati

Alarm Mati Nyala (berkedip)

Kunci trip Nyala Nyala (berkedip)

Ilustrasi 7.2 Lampu Indikator Status

7.3 Daftar Peringatan dan Alarm

Informasi peringatan dan alarm berikut menjelaskanmasing-masing kondisi peringatan atau alarm,kemungkinan penyebab kondisi tersebut, serta saran rincitentang prosedur mengatasi atau memecahkannya.

PERINGATAN 1, 10 Volt rendahTegangan kartu kontrol kurang dari 10 V dari terminal 50.Kurangi beban dari terminal 50, karena catu 10 V kelebihanbeban. Maksimum 15 mA atau minimum 590 Ω.

Arus pendek pada potensiometer yang tersambung atauakibat kesalahan penyambungan potensiometer dapatmengakibatkan kondisi ini.

Pemecahan masalah• Lepas kabel dari terminal 50. Jika peringatan

hilang, masalahnya ada pada sambungan kabel.Jika peringatan tidak hilang, ganti kartu kontrol.

PERINGATAN/ALARM 2, Kesalahan zero aktifPeringatan atau alarm ini hanya muncul apabila diprogramoleh pengguna di parameter 6-01 Fungsi Istirahat arus/teg.t'lalu rdh. Sinyal pada 1 input analog kurang dari 50% nilaiminimum yang diprogram untuk input tersebut. Kerusakankabel atau kesalaham perangkat yang mengirim sinyaldapat menyebabkan kondisi ini.

Pemecahan masalahPeriksa sambungan pada semua terminalinput.analog. Terminal kartu kontrol 53 dan 54untuk sinyal, terminal 55 umum. VLT® GeneralPurpose I/O MCB 101 terminal 11 dan 12 untuksinyal, terminal 10 umum. VLT® Analog I/O MCB109 terminal 1, 3, 5 untuk sinyal, terminal 2, 4, 6umum.

Pastikan pengaturan program konverter frekuensidan switch cocok dengan jenis sinyal analog.

Melakukan Tes Sinyal Terminal Input.

PERINGATAN/ALARM 3, Tak ada motorTak ada motor yang telah dihubungkan ke keluaran darikonverter frekuensi.

PERINGATAN/ALARM 4, Fasa sumber listrik hilangSalah satu fasa hilang pada sisi pasokan, atau ketidakseim-bangan voltase sumber listrik terlalu tinggi. Pesan ini jugamuncul jika ada masalah pada rektifier input. Opsidiprogram pada parameter 14-12 Fungsi pd Ketidak-seimbangan Sumb..

Pemecahan masalah• Periksa voltase dan arus catu ke konverter

frekuensi.

PERINGATAN 5, Voltase DC-link tinggiVoltase DC-link lebih tinggi daripada batas peringatanvoltase tinggi. Batas bergantung pada rating voltasekonverter frekuensi. Unit masih aktif.

PERINGATAN 6, Voltase DC-link RendahVoltase DC-link lebih rendah daripada batas peringatanvoltase rendah. Batas bergantung pada rating voltasekonverter frekuensi. Unit masih aktif.

PERINGATAN/ALARM 7, Kelebihan voltase DCJika tegangan DC-link terlalu besar, konverter frekuensiakan trip setelah waktu tertentu.

Pemecahan masalah• Pasang resistor rem.

• Perpanjang waktu akselerasi/deselerasi

• Ubah tipe akselerasi/deselerasi

• Aktifkan fungsi di parameter 2-10 Fungsi Brake.

• Naikkan parameter 14-26 Pnunda.Trip pd KrusakPmblk..

PERINGATAN/ALARM 8, Voltase DC kurangJika voltase DC-link turun di bawah batas voltase kurang,konverter frekuensi akan memeriksa apakah catu dayacadangan 24 V DC tersambung. Jika catu daya cadangan24 V DC tidak tersambung, konverter frekuensi akan tripsetelah jeda waktu tertentu. Jeda hingga mati bervariasitergantung ukuran unit.

Pemecahan masalah• Pastikan voltase pasokan sama dengan voltase

konverter frekuensi.

• Lakukan tes voltase input.

• Melakukan pemeriksaan ringan tes sirkuit.

PERINGATAN/ALARM 9, Inverter kelebihan bebanKonverter frekuensi beroperasi dengan kelebihan bebanlebih dari 100% terlalu lama dan hampir mati. Penghitungperlindungan termal elektronik lnverter mengeluarkanperingatan jika kelebihan beban mencapai 98% dan anjloksaat mencapai 100% dengan sebuah alarm. Konverterfrekuensi tidak dapat direset sampai penghitungmenunjukkan angka di bawah 90%.

Pemeliharaan, Diagnostik, d... VLT® AutomationDrive FC 301/302

24 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

77

Page 27: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Pemecahan masalah• Bandingkan arus output yang ditampilkan pada

LCP dengan rating arus konverter frekuensi.

• Bandingkan arus output yang ditampilkan padaLCP dengan arus motor terukur.

• Tampilkan beban konverter frekeunsi termal padaLCP dan awasi nilainya. Saat beroperasi di atasrating arus kontinu konverter frekuensi, hitunganmeningkat. Saat beroperasi di bawah rating aruskontinu konverter frekuensi, hitungan berkurang.

PERINGATAN/ALARM 10, Suhu kelebihan beban motorMenurut proteksi termal elektronik (ETR), motor terlalupanas.

Pilih 1 dari opsi berikut:• Konverter mengeluarkan peringatan atau alarm

saat penghitung >90% jikaparameter 1-90 Proteksi pd termal motor diatur keopsi peringatan.

• Konverter frekuensi anjlok saat penghitungmencapai 100% jika parameter 1-90 Proteksi pdtermal motordiatur ke opsi anjlok.

Masalah muncul jika motor beroperasi dengan kelebihanbeban di atas 100% terlalu lama.

Pemecahan masalah• Periksa apakah motor terlalu panas.

• Periksa apakah motor secara mekanis kelebihanbeban.

• Pastikan arus motor yang ditetapkan dalamparameter 1-24 Arus Motor sudah benar.

• Pastikan data motor yang ditetapkan dalamparameter 1-20 hingga 1-25 sudah benar.

• Jika menggunakan kipas eksternal, pastikan kipastersebut dipilih di parameter 1-91 Kipas EksternalMotor.

• Menjalankan AMA di parameter 1-29 PenyesuaianMotor Otomatis (AMA) menyelaraskan konverterfrekuensi terhadap motor secara lebih akurat danmengurangi beban termal.

PERINGATAN/ALARM 11, Suhu termistor motor terlalutinggiPeriksa apakah sambungan termistor lepas. Pilih peringatanatau alarm yang akan dikeluarkan oleh konverter frekuensidalam parameter 1-90 Proteksi pd termal motor.

Pemecahan masalah• Periksa apakah motor terlalu panas.

• Periksa apakah motor secara mekanis kelebihanbeban.

• Saat menggunakan terminal 53 atau 54, periksaapakah termistor terhubung dengan benar keterminal 53 atau 54 (input voltase analog) danterminal 50 (catu +10 V). Periksa juga apakah

sakelar terminal untuk 53 atau 54 siap menerimavoltase. Periksa apakah parameter 1-93 SumberTermistor memilih terminal 53 atau 54.

• Saat menggunakan terminal 18, 19, 31, 32, atau33, periksa apakah termistor terhubung denganbenar ke terminal input digital yang digunakan(PNP input digital saja) dan terminal 50. Pilihterminal yang akan digunakan dalamparameter 1-93 Sumber Termistor.

PERINGATAN/ALARM 12, Batas torsiTorsi melampaui nilai dalam parameter 4-16 Mode MotorBatasan Torsi atau nilai dalam parameter 4-17 Modegenerator Batasan Torsi. Parameter 14-25 Penundaan Trippada Batasan Torsi dapat mengubah peringatan ini darikondisi dengan peringatan saja menjadi peringatan yangdiikuti alarm.

Pemecahan masalah• Jika torsi motor terlampaui selama akselerasi,

perpanjang waktu ramp-up.

• Jika batas torsi generator terlampaui selamadeselerasi, perpanjang waktu ramp-downi.

• Jika batas torsi tercapai selama beroperasi,naikkan batas torsi. Pastikan sistem dapatberoperasi dengan aman pada torsi lebih tinggi.

• Cek apakah tindakan ini menyebabkan arus yangtertarik ke motor terlalu besar.

PERINGATAN/ALARM 13, Kelebihan arusBatas arus puncak inverter (sekitar 200% dari ratingarusnya) terlampaui. Peringatan berlangsung sekitar 1,5 d,kemudian konverter frekuensi trip dan mengeluarkanalarm. Beban kejut atau akselerasi cepat dengan bebaninersia tinggi dapat menyebabkan masalah ini. Jikaakselerasi selama ramp-up cepat, masalah juga dapatmuncul setelah kinetic back-up.Jika ekstensi kontrol rem mekanis dipilih, trip dapat diresetsecara eksternal.

Pemecahan masalah• Matikan daya dan periksa apakah poros motor

dapat diputar.

• Pastikan ukuran motor cocok dengan konverterfrekuensi.

• Pastikan data motor dalam parameter 1-20 hingga1-25 sudah benar.

ALARM 14, Pembumian (pentanah) BermasalahTerdapat arus dari fasa output ke pembumi, baik di dalamkabel di antara konverter frekuensi dan motor, maupun didalam motor itu sendiri. Transduser arus mendeteksimasalah pembumian dengan mengukur arus yang keluardari dan masuk ke konverter frekuensi. Pembumibermasalah muncul jika penyimpangan ke 2 arus terlalubesar. Arus keluar dari konverter frekuensi harus samadengan arus yang masuk.

Pemeliharaan, Diagnostik, d... Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 25

7 7

Page 28: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Pemecahan masalah• Matikan daya ke konverter frekuensi dan perbaiki

masalah pembumi.

• Periksa masalah pada pembumi di dalam motordengan mengukur resistansi ke pembumi kabelmotor dan motor dengan megohmmeter.

• Reset potensi offset individu dalam 3 transduserarus dalam konverter frekuensi. Lakukan inisia-lisasi manual atau AMA lengkap. Metode iniadalah paling relevan selain mengganti papandaya.

ALARM 15, Ketidakcocokan Perangkat KerasOpsi terpasang tidak dapat dioperasikan dengan perangkatkeras atau perangkat lunak kartu kontrol yang ada.

Catat nilai parameter berikut kemudian hubungi Danfoss.• Parameter 15-40 Jenis FC.

• Parameter 15-41 Bagian Daya.

• Parameter 15-42 Tegangan.

• Parameter 15-43 Versi Perangkat Lunak.

• Parameter 15-45 Untaian Jenis kode Aktual.

• Parameter 15-49 Kartu Kontrol ID SW.

• Parameter 15-50 Kartu Daya ID SW.

• Parameter 15-60 Pilihan Terangkai.

• Parameter 15-61 Versi SW Pilihan (untuk setiap slotopsi).

ALARM 16, Arus pendekTerjadi arus pendek dalam motor atau perkawatan motor.

Pemecahan masalah• Matikan daya ke konverter frekuensi dan perbaiki

arus pendek.

PERINGATANTEGANGAN TINGGIKonverter frekuensi mengandung voltase tinggi saatterhubung ke sumber listrik AC, catu daya DC, ataupembagi beban. Pemasangan, penyalaan, dan perawatankonverter frekuensi selain oleh teknisi yang cakap dapatmengakibatkan kematian atau cidera serius.

• Matikan daya sebelum melanjutkan.

PERINGATAN/ALARM 17, Kata kontrol kehabisan waktuTidak ada komunikasi ke konverter frekuensi.Peringatan hanya aktif bila parameter 8-04 Fungsi IstirahatKata Kontrol TIDAK diatur ke [0] Padam.Jika parameter 8-04 Fungsi Istirahat Kata Kontrol diatur ke[5] Berhenti dan trip, peringatan muncul, konverterfrekuensi berdeselerasi hingga berhenti dan mengeluarkanalarm.

Pemecahan masalah• Periksa sambungan kabel komunikasi seri.

• Naikkan parameter 8-03 Waktu Istirahat KataKontrol.

• Periksa operasional peralatan komunikasi.

• Pastikan pemasangan EMC dilakukan denganbenar.

PERINGATAN/ALARM 20, Kesalahan input suhuSensor suhu tidak tersambung.

PERINGATAN/ALARM 21, Kesalahan parameterParameter di luar jangkauan. Nomor parameter ditampilkandi layar.

Pemecahan masalah• Atur parameter terdampak ke nilai yang valid.

PERINGATAN/ALARM 22, Rem mekanis pengangkatNilai peringatan/alarm ini menunjukkan penyebabnya:.0 = Referensi torsi tidak tercapai sebelum waktu habis(parameter 2-27 Waktu Ramp Torsi).1 = Umpan balik yang diharapkan tidak diterima sebelumwaktu habis (parameter 2-23 Aktifkan Penundaan Brake/Rem,parameter 2-25 Waktu Pelepasan Rem).

PERINGATAN 23, Kipas Internal BermasalahFungi peringatan kipas adalah sebuah fungsi perlindunganyang memeriksa apakah kipas berjalan/terpasang.Peringatan kipas dapat dinonaktifkan diparameter 14-53 Monitor Kipas ([0] Dinonaktif).

Kipas dilengkapi sensor umpan-balik. Jika kipas diperin-tahkan berjalan dan tidak ada umpan-balik dari sensor,alarm ini muncul. Alarm ini juga menunjukkan adakesalahan komunikasi antara papan daya kipas dan kartukontrol.

Periksa log alarm (lihat bab 5.2 Operasi Panel Kontrol Lokal)untuk nilai laporan terkait peringatan ini.

Jika nilai laporan adalah 2, ada masalah perangkat kerasdengan 1 kipas. Jika nilai laporan adalah 12, ada masalahkomunikasi antara papan daya kipas dan kartu kontrol.

Memecahkan masalah pada kipas• Matikan lalu alirkan kembali daya ke konverter

frekuensi dan lihat apakah kipas beroperasisejenak selama penyalaan.

• Lihat apakah kipas beroperasi dengan benar.Gunakan grup parameter 43-** Unit Readoutsuntuk menampilkan kecepatan masing-masingkipas.

Mengatasi masalah pada papan daya kipas• Periksa sambungan antara papan daya kipas dan

kartu kontrol.

• Papan daya kipas mungkin perlu diganti.

• Kartu kontrol mungkin perlu diganti.

Pemeliharaan, Diagnostik, d... VLT® AutomationDrive FC 301/302

26 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

77

Page 29: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

PERINGATAN 24, Kipas Eksternal BermasalahFungi peringatan kipas adalah sebuah fungsi perlindunganyang memeriksa apakah kipas berjalan/terpasang.Peringatan kipas dapat dinonaktifkan diparameter 14-53 Monitor Kipas ([0] Dinonaktif).

Kipas dilengkapi sensor umpan-balik. Jika kipas diperin-tahkan berjalan dan tidak ada umpan-balik dari sensor,alarm ini muncul. Alarm ini juga menunjukkan adakesalahan komunikasi antara papan daya dan kartukontrol.

Periksa log alarm (lihat bab 5.2 Operasi Panel Kontrol Lokal)untuk nilai laporan terkait peringatan ini.

Jika nilai laporan adalah 1, ada masalah perangkat kerasdengan 1 dari kipas-kipas tersebut. Jika nilai laporanadalah 11, ada masalah komunikasi antara papan daya dankartu kontrol.

Memecahkan masalah pada kipas• Matikan lalu alirkan kembali daya ke konverter

frekuensi dan lihat apakah kipas beroperasisejenak selama penyalaan.

• Lihat apakah kipas beroperasi dengan benar.Gunakan grup parameter 43-** Unit Readoutsuntuk menampilkan kecepatan masing-masingkipas.

Mengatasi masalah pada papan daya• Periksa sambungan antara papan daya dan kartu

kontrol.

• Papan daya mungkin perlu diganti.

• Kartu kontrol mungkin perlu diganti.

PERINGATAN 25, Resistor rem korsletResistor rem dimonitor selama operasi. Jika terjadi korslet,fungsi rem dimatikan dan peringatan muncul. Konverterfrekuensi masih bisa beroperasi, tapi tanpa fungsipengereman.

Pemecahan masalah• Matikan daya ke konverter frekuensi kemudian

ganti resistor rem (lihat parameter 2-15 Cek Brake).

PERINGATAN/ALARM 26, Batas daya resistor remDaya yang dialirkan ke resistor rem dihitung sebagai nilairata-rata selama pengoperasian 120 detik terakhir.Perhitungan ini mengacu pada voltase DC-link dan nilairesistor rem yang diatur dalam parameter 2-16 Arus Maks.rem AC. Peringatan akan aktif saat daya pengereman yanghilang lebih tinggi dari 90% daya resistor rem. Apabila opsi[2] Trip dipilih dalam parameter 2-13 Pemantauan DayaBrake, konverter frekuensi trip saat daya pengereman yanghilang mencapai 100%.

PERINGATAN/ALARM 27, Fungsi Rem BermasalahTransistor rem dimonitor selama pengoperasian, dan jikaterjadi korslet, fungsi rem dimatikan, dan peringatandikeluarkan. Konverter frekuensi masih dapat dioperasikan,tapi karena resistor rem korsleting, daya dalam jumlahbesar mengalir ke resistor rem, bahkan saat alat tidak aktif.

Pemecahan masalah• Akhiri daya ke konverter frekuensi lalu lepas

resistor rem.

PERINGATAN/ALARM 28, Pemeriksaan rem gagalpenahan rem tidak terhubung atau tidak bekerja.

Pemecahan masalah• Periksa parameter 2-15 Cek Brake.

ALARM 29, Suhu heatsinkSuhu maksimum heat sink terlampaui. Kesalahan suhutidak direset sampai suhu turun di bawah suhu yangditentukan untuk heat sink. Titik trip dan reset bervariasimenurut ukuran daya konverter frekuensi.

Pemecahan masalahPeriksa kondisi berikut:

• Suhu sekitar terlalu tinggi.

• Kabel motor yang terlalu panjang.

• Ruang bebas untuk aliran udara di atas dan dibawah konverter kurang.

• Aliran udara di sekitar konverter terhalang.

• Kipas unit pendingin rusak.

• Unit pendingin kotor.

ALARM 30, Fasa Motor U HilangFasa motor U antara konverter frekuensi dan motor hilang.

PERINGATANTEGANGAN TINGGIKonverter frekuensi mengandung voltase tinggi saatterhubung ke sumber listrik AC, catu daya DC, ataupembagi beban. Pemasangan, penyalaan, dan perawatankonverter frekuensi selain oleh teknisi yang cakap dapatmengakibatkan kematian atau cidera serius.

• Matikan daya sebelum melanjutkan.

Pemecahan masalah• Matikan daya dari konverter frekuensi dan periksa

fasa motor U.

ALARM 31, Fasa Motor V HilangFasa motor V antara konverter frekuensi dan motor hilang.

PERINGATANTEGANGAN TINGGIKonverter frekuensi mengandung voltase tinggi saatterhubung ke sumber listrik AC, catu daya DC, ataupembagi beban. Pemasangan, penyalaan, dan perawatankonverter frekuensi selain oleh teknisi yang cakap dapatmengakibatkan kematian atau cidera serius.

• Matikan daya sebelum melanjutkan.

Pemecahan masalah• Matikan daya dari konverter frekuensi dan periksa

fasa motor V.

Pemeliharaan, Diagnostik, d... Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 27

7 7

Page 30: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

ALARM 32, Fasa W Motor HilangFasa motor W antara konverter frekuensi dan motor hilang.

PERINGATANTEGANGAN TINGGIKonverter frekuensi mengandung voltase tinggi saatterhubung ke sumber listrik AC, catu daya DC, ataupembagi beban. Pemasangan, penyalaan, dan perawatankonverter frekuensi selain oleh teknisi yang cakap dapatmengakibatkan kematian atau cidera serius.

• Matikan daya sebelum melanjutkan.

Pemecahan masalah• Matikan daya dari konverter frekuensi dan periksa

fasa motor W.

ALARM 33, Masalah lonjakan arusTerlalu sering terjadi lonjakan daya dalam waktu singkat.

Pemecahan masalah• Biarkan unit dingin hingga mencapai suhu

pengoperasian.

PERINGATAN/ALARM 34, Komunikasi Fieldbus BermasalahFieldbus pada kartu opsi komunikasi tidak bekerja.

PERINGATAN/ALARM 35, Opsi bermasalahAlarm opsi diterima. Alarm merupakan opsi yang spesifik.Kemungkinan penyebabnya adalah power-up atau masalahkomunikasi.

PERINGATAN/ALARM 36, Kegagalan sumber listrikPeringatan/alarm ini hanya aktif apabila pasokan teganganke konverter frekuensi hilang danparameter 14-10 Kegagalan power listrik TIDAK diatur ke [0]Tidak ada Fungsi. Periksa sekering ke konverter frekuensidan pasokan hantaran listrik ke unit.

ALARM 37, Ketidakseimbangan fasaAdanya arus tidak seimbang diantara unit daya.

ALARM 38, Internal fault (Masalah internal)Saat terjadi masalah internal, nomor kode yang ditetapkandalam Tabel 7.1 muncul.

Pemecahan masalah• Matikan lalu alirkan kembali daya.

• Periksa apakah opsi dipasang secara benar.

• Periksa apakah kabel longgar atau hilang.

Bila perlu, hubungi pemasok atau bagian servis Danfoss .Catatan nomor kode untuk petunjuk pemecahan masalahselanjutnya.

Nomor Teks

0 Port seri tidak dapat diinisialisasi. Hubungipemasok Danfoss atau bagian servis Danfoss.

256–258 Data EEPROM daya rusak atau terlalu tua. Gantipapan daya.

512–519 Masalah internal Hubungi pemasok Danfoss ataubagian servis Danfoss.

Nomor Teks

783 Nilai parameter di luar batas minimum/maksimum.

1024–1284 Masalah internal Hubungi pemasok Danfoss ataubagian servis Danfoss.

1299 Perangkat lunak opsi pada slot A terlalu tua.

1300 Perangkat lunak opsi pada slot B terlalu tua.

1302 Perangkat lunak opsi pada slot C1 terlalu tua.

1315 Perangkat lunak opsi pada slot A tidak didukung/diizinkan.

1316 Perangkat lunak opsi pada slot B tidak didukung/diizinkan.

1318 Perangkat lunak opsi pada slot C1 tidak didukung/diizinkan.

1379–2819 Masalah internal Hubungi pemasok Danfoss ataubagian servis Danfoss.

1792 Reset perangkat keras prosesor sinyal digital.

1793 Parameter yang diperoleh dari motor tidakditransfer secara benar ke prosesor sinyal digital.

1794 Data daya tidak ditransfer secara benar saatpenyalaan ke prosesor sinyal digital.

1795 Prosesor sinyal digital menerima terlalu banyaktelegram SPI tidak dikenal. Konverter frekuensi ACjuga menggunakan kode kesalahan ini jika MCOtidak menyala dengan benar. Masalah ini dapatterjadi karena buruknya proteksi EMC ataukesalahan pembumian.

1796 Kesalahan menyalin RAM.

1798 Kartu kontrol MK1 menggunakan perangkat lunakversi 48.3X ke atas. Ganti dengan kartu kontrol 8keluaran MKII.

2561 Ganti kartu kontrol.

2820 Tumpukan LCP terlalu tinggi.

2821 Tumpukan port seri terlalu tinggi.

2822 Tumpukan port USB terlalu tinggi.

3072–5122 Nilai parameter di luar batas.

5123 Opsi di Slot A: Perangkat keras tidak kompatibeldengan perangkat keras pada papan kontrol.

5124 Opsi di Slot B: Perangkat keras tidak kompatibeldengan perangkat keras pada papan kontrol.

5125 Opsi di Slot C0: Perangkat keras tidak kompatibeldengan perangkat keras pada papan kontrol.

5126 Opsi di Slot C1: Perangkat keras tidak kompatibeldengan perangkat keras pada papan kontrol.

5376–6231 Masalah internal Hubungi pemasok Danfoss ataubagian servis Danfoss.

Tabel 7.1 Kode Masalah internal

ALARM 39, Sensor unit pendinginTidak ada umpan balik dari sensor suhu unit pendingin.

Sinyal dari sensor termal IGBT tidak tersedia pada papandaya. Masalah mungkin ada pada papan daya, kartugatedrive, atau kabel pita antara papan daya dan kartugatedrive.

Pemeliharaan, Diagnostik, d... VLT® AutomationDrive FC 301/302

28 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

77

Page 31: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

PERINGATAN 40, Terminal output digital 27 kelebihanbebanPeriksa beban yang terhubung ke terminal 27 atau lepassambungan korslet. Periksa parameter 5-00 Mode I/O Digitaldan parameter 5-01 Mode Terminal 27.

PERINGATAN 41, Terminal output digital 29 kelebihanbebanPeriksa beban yang terhubung ke terminal 29 atau lepassambungan korslet. Periksa juga parameter 5-00 Mode I/ODigital dan parameter 5-02 Modus Terminal 29.

PERINGATAN 42, Output Digital pada X30/6 atau X30/7Kelebihan BebanUntuk terminal X30/6, periksa beban yang terhubung keterminal X30/6 atau lepas sambungan korslet. Periksa jugaGeneral Purpose I/O parameter 5-32 Term X30/6 Kel Digi(MCB 101) (VLT® MCB 101).

Untuk terminal X30/7, periksa beban yang terhubung keterminal X30/7 atau lepas sambungan korslet. Periksaparameter 5-33 Term X30/7 Kel Digi (MCB 101) (VLT® GeneralPurpose I/O MCB 101).

ALARM 43, Perpanjangan catuVLT® Extended Relay Option MCB 113 dipasang tanpa 24 VDC eksternal. Hubungkan catu daya eksternal 24 V DC ataupilih tidak menggunakan catu daya eksternal lewatparameter 14-80 Opsi Di berikan oleh 24VDC Eksternal, [0]Tidak. Perubahan dalam parameter 14-80 Opsi Di berikanoleh 24VDC Eksternal mengharuskan daya dimatikankemudian dialirkan kembali.

ALARM 45, Masalah Pembumi 2Masalah Pembumi.

Pemecahan masalah• Periksa untuk Pembumi yang benar dan lepaskan

sambungan.

• Pastikan ukuran kabel sudah benar.

• Periksa kabel motor apakah korslet ataumengalami kebocoran arus.

ALARM 46, Catu papan dayaCatu dari papan daya di luar rentang. Penyebab lainnyamungkin kipas unit pendingin rusak.

Ada 3 catu yang dihasilkan oleh catu mode saklar (SMPS)pada papan daya:

• 24 V.

• 5 V.

• ±18 V.

Saat daya dialirkan dari Catu Daya 24 V DC VLT® MCB 107,hanya catu 24 V dan 5 V yang termonitor. Saat dayadialirkan dari voltase sumber listrik 3 fasa, ke 3 catutermonitor.

Pemecahan masalah• Periksa apakah papan daya mengalami kerusakan.

• Periksa apakah kartu kontrol rusak.

• Periksa apakah kartu opsi rusak.

• Jika menggunakan catu daya 24 V DC, pastikandaya yang dialirkan sudah sesuai.

• Periksa apakah kipas unit pendingin rusak.

PERINGATAN 47, Catu 24 V kurangCatu dari papan daya di luar rentang.

Ada 3 catu yang dihasilkan oleh catu mode saklar (SMPS)pada papan daya:

• 24 V.

• 5 V.

• ±18 V.

Pemecahan masalah• Periksa apakah papan daya mengalami kerusakan.

PERINGATAN 48, Catu 1.8 V rendahPasokan 1,8 V DC yang digunakan pada kartu kontrolberada di luar batas yang diperbolehkan. Pasokan diukurpada kartu kontrol.

Pemecahan masalah• Periksa apakah kartu kontrol rusak.

• Apabila kartu opsi telah ada, periksa untukkelebihan tegangan.

PERINGATAN 49, Batas kecepatanPeringatan muncul jika kecepatan berada di luar rentangyang ditetapkan dalam parameter 4-11 Batasan RendahKecepatan Motor [RPM] dan parameter 4-13 Batasan TinggiKecepatan Motor [RPM]. Saat kecepatan kurang dari batasyang ditetapkan dalam parameter 1-86 Kecepatan TripRendah [RPM] (kecuali saat dinyalakan atau berhenti),konverter frekuensi akan trip.

ALARM 50, Kalibrasi AMA gagalHubungi pemasok Danfoss atau Bagian ServisDanfoss.

ALARM 51, AMA check Unom and Inom

Pengaturan voltase, arus, dan daya motor salah.

Pemecahan masalah• Periksa pengaturan di parameter 1-20 hingga 1-25.

ALARM 52, AMA low Inom

Arus motor terlalu rendah.

Pemecahan masalah• Periksa pengaturan diparameter 1-24 Arus Motor.

ALARM 53, Motor AMA terlalu besarMotor terlalu besar untuk melaksanakan AMA.

ALARM 54, Motor AMA terlalu kecilMotor terlalu kecil untuk melaksanakan AMA.

ALARM 55, Parameter AMA Di Luar RentangAMA tidak dapat dilakukan karena nilai parameter motor diluar rentang yang dapat diterima.

ALARM 56, AMA dihentikan oleh penggunaAMA sedang secara manual diputus.

Pemeliharaan, Diagnostik, d... Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 29

7 7

Page 32: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

ALARM 57, Masalah internal AMACoba start ulang AMA. Sering mengulangi start dapatmengakibatkan motor terlalu panas.

ALARM 58, Masalah Internal AMAHubungi Danfoss pemasok.

PERINGATAN 59, Batas arusArus lebih tinggi daripada nilai pada parameter 4-18 BatasArus. Pastikan data motor yang ditetapkan dalamparameter 1-20 hingga 1-25 sudah benar. Naikkan batasarus apabila diperlukan. Pastikan sistem dapat beroperasidengan aman pada batas lebih tinggi.

PERINGATAN 60, Interlock eksternalSinyal input digital menandakan adanya kondisibermasalah di luar konverter frekuensi. Interlock eksternaltelah memerintahkan konverter frekuensi untuk anjlok.

Pemecahan masalah• Atasi dulu masalah eksternal.

• Untuk dapat melanjutkan pengoperasian secaranormal, alirkan 24 V DC ke terminal yangdiprogram untuk interlock eksternal.

• Reset konverter frekuensi.

PERINGATAN/ALARM 61, Kesalahan umpan-balikTerdeteksi kesalahan antara perhitungan kecepatan danpengukuran kecepatan dari perangkat umpan-balik.

Pemecahan masalah• Periksa pengaturan peringatan/alarm/

penonaktifan di parameter 4-30 Fungsi RugiUmpan-balik Motor.

• Tetapkan toleransi kesalahan diparameter 4-31 Kesalahan Kecepatan Umpan-balikMotor.

• Tetapkan toleransi waktu akibat hilangnya umpanbalik di parameter 4-32 Timeout Rugi Umpan-balikMotor.

PERINGATAN 62, Frekuensi output pada batas maksimumJika frekuensi output mencapai nilai yang ditetapkandalamparameter 4-19 Frekuensi Output Maks., konvertermengirim peringatan. Peringatan menjadi hilang pada saatoutput turun di bawah batas maksimum. Jika tidak dapatmembatasi frekuensi, konverter anjlok dan mengirim alarm.Alarm dapat terjadi dalam mode fluks jika konverterkehilangan kontrol atas motor.

Pemecahan masalah• Periksa aplikasi untuk penyebab kemungkinan.

• Tingkatkan batas frekuensi output. Pastikansistem dapat beroperasi dengan aman pada batasfrekuensi lebih tinggi.

ALARM 63, Rem mekanis rendahArus motor yang sebenarnya tidak melampaui aruspelepasan rem di dalam jendela waktu mulai waktu tunda.

PERINGATAN 64, Batas VoltaseKombinasi beban dan kecepatan menghendaki teganganmotor yang lebih tinggi daripada tegangan hubungan DCyang sesungguhnya.

PERINGATAN/ALARM 65, Suhu kartu kontrol terlalu tinggiSuhu pematian kartu kontrol adalah 85 °C (185 °F).

Pemecahan masalah• Pastikan suhu lingkungan pengoperasian di

dalam batas yang ditentukan.

• Periksa apakah filter tersumbat.

• Periksa operasi kipas.

• Periksa kartu kontrol.

PERINGATAN 66, Suhu unit pendingin rendahKonverter frekuensi terlalu dingin untuk beroperasi.Peringatan ini mengacu pada sensor suhu dalam modulIGBT. Naikkan suhu lingkungan unit. Sedikit arus jugadapat dialirkan ke konverter saat motor berhenti denganmengatur parameter 2-00 Arus Penahan DC/Prapanas ke 5%dan parameter 1-80 Fungsi saat Stop.

ALARM 67, Konfigurasi modul opsi telah berubahSatu atau beberapa opsi telah ditambahkan atau dihapussejak daya yang terakhir kali turun. Periksa bahwaperubahan konfigurasi ditujukan dan melakukan reset.

ALARM 68, Safe Stop DiaktifkanSafe torque off (STO) telah diaktifkan. Untuk melanjutkanpengoperasian secara normal, alirkan 24 V DC ke terminal37, lalu kirim sinyal reset (via bus, I/O digital, atau denganmenekan [Reset].

ALARM 69, Suhu papan dayaSensor suhu pada papan daya terlalu panas atau dingin.

Pemecahan masalah• Pastikan suhu lingkungan pengoperasian di

dalam batas yang ditentukan.

• Periksa apakah filter tersumbat.

• Periksa operasi kipas.

• Periksa papan daya.

ALARM 70, Konfigurasi FC ilegalKartu kontrol dan papan daya tidak cocok. Untukmemastikan kompatibilitas, hubungi pemasok Danfossdengan menyebutkan kode tipe dari pelat nama unit dannomor komponen kartu.

ALARM 71, safe stop PTC 1STO telah diaktifkan dari VLT® PTC Thermistor Card MCB112 (motor terlalu hangat). Pengoperasian secara normaldapat dilanjutkan setelah MCB 112 kembali mengalirkan 24V DC ke terminal 37 (setelah suhu motor mencapai tingkatyang dapat diterima) dan saat input digital dari MCB 112dinonaktifkan. Saat ini terjadi, kirim sinyal reset (via busatau I/O digital, atau tekan [Reset]).

Pemeliharaan, Diagnostik, d... VLT® AutomationDrive FC 301/302

30 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

77

Page 33: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

ALARM 72, Kegagalan berbahaya

STO dengan kunci anjlok. Terjadi kombinasi tak terdugaperintah STO:

• VLT® PTC Thermistor Card MCB 112 mengaktifkanX44/10, tapi STO tidak diaktifkan.

• MCB 112 adalah satu-satunya perangkat yangmenggunakan STO (ditentukan dengan memilih[4] PTC 1 alarm or [5] PTC 1 peringatan dalamparameter 5-19 Terminal 37 Berhenti Aman), STOdiaktifkan, dan X44/10 tidak diaktifkan.

PERINGATAN 73, Restart Otomatis Safe StopSTO diaktifkan. Jika restart otomatis diaktifkan, motordapat dinyalakan kembali setelah masalah teratasi.

ALARM 74, Termistor PTCAlarm yang berhubungan dengan VLT® PTC ThermistorCard MCB 112. PTC tidak bekerja.

ALARM 75, Sel. profil ilegalJangan menuliskan nilai parameter saat motor berjalan.Matikan motor sebelum menuliskan profil MCO keparameter 8-10 Profil Kata Kontrol.

PERINGATAN 77, Modus pengurangan dayaKonverter frekuensi beroperasi dalam mode pengurangandaya (kurang dari toleransi jumlah bagian inverter).Peringatan ini mucul selama siklus daya ketika konverterfrekuensi diatur beroperasi dengan beberapa inverter dantetap aktif.

ALARM 78, Kesalahan lacakSelisih antara nilai tetapan dan nilai aktual melampaui nilaidalam parameter 4-35 Salah Pelacak.

Pemecahan masalah• Matikan fungsi ini atau pilih alarm/peringatan

dalam parameter 4-34 Fungsi salah lacak.

• Selidiki mekanika sekitar beban dan motor.Periksa sambungan umpan-balik dari enkodermotor ke konverter frekuensi.

• Pilih fungsi umpan-balik motor diparameter 4-30 Fungsi Rugi Umpan-balik Motor.

• Sesuaikan pita kesalahan lacak diparameter 4-35 Salah Pelacak danparameter 4-37 Ramp Salah lacak.

ALARM 79, Konfigurasi seksi daya ilegalNomor komponen pada kartu penskalaan salah atau kartupenskalaan tidak dipasang. Konektor MK 102 pada kartudaya tidak dapat dipasang.

ALARM 80, Konverter diinisialisasi ke nilai standarPengaturan standar diinisialisasi ke pengaturan standarsetelah reset manual. Untuk menghapus alarm, reset unit.

ALARM 81, CSIV korupFile CSIV mengalami kesalahan sintaks.

ALARM 82, Kesalahan parameter CSIVCSIV gagal untuk menginisialisasi parameter.

ALARM 83, Kombinasi opsi ilegalOpsi pemasangan tidak cocok.

ALARM 84, Tidak ada opsi pengamananOpsi pengaman dilepas tanpa menetapkan reset umum.Sambung kembali opsi pengaman.

ALARM 88, Deteksi OpsiPerubahan tata letak opsi terdeteksi.Parameter 14-89 Option Detection diatur ke [0] Konfigurasibeku dan tata letak opsi telah diubah.

• Untuk menerapkan perubahan, aktifkanperubahan tata letak opsi diparameter 14-89 Option Detection.

• Atau, kembalikan konfigurasi opsi yang benar.

PERINGATAN 89, Geser rem mekanisMonitor rem hoist mendeteksi kecepatan motormelampaui 10 RPM.

ALARM 90, Monitor umpan-balikPeriksa sambungan ke opsi pengkode/resolver dan, bilaperlu, ganti VLT® Encoder Input MCB 102 atau VLT®

Resolver Input MCB 103.

ALARM 91, Pengaturan input analog 54 salahAtur saklar S202 di posisi OFF (input tegangan) ketikasensor KTY terhubung ke terminal masukan analog 54.

ALARM 99, Rotor terkunciRotor terhalang

PERINGATAN/ALARM 104, Kipas pencampur bermasalahKipas tidak beroperasi. Monitor kipas memastikan kipasberputar saat penyalaan atau kapan saja kipas pencampurdihidupkan. Masalah pada kipas pencampur dapat dikonfi-gurasi sebagai peringatan atau pemicu alarm dalamparameter 14-53 Monitor Kipas.

Pemecahan masalah• Matikan kemudian alirkan lagi daya ke konverter

frekuensi untuk melihat apakah peringatan/alarmmuncul kembali.

PERINGATAN/ALARM 122, Rotasi motor tiba-tibaKonverter frekuensi menjalankan fungsi yang memerlukanmotor pada posisi stasioner, DC hold untuk motor PM.

PERINGATAN 163, ATEX ETR peringatan batas kur.Konverter frekuensi beroperasi di atas karakteristik kurvauntuk yang lebih dari 50 detik. Peringatan muncul saattoleransi kelebihan beban panas mencapai 83% dan hilangpada angka 65%.

ALARM 164, ATEX ETR alarm batas kur.Beroperasi di atas kurva karakteristik selama lebih dari60 d dalam periode 600 detik mengaktifkan alarm dankonverter frekuensi akan trip.

PERINGATAN 165, ATEX ETR peringatan batas frek.Konverter frekuensi beroperasi selama lebih dari 50 d dibawah frekuensi minimum yang dibolehkan(parameter 1-98 ATEX ETR interpol. points freq.).

Pemeliharaan, Diagnostik, d... Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 31

7 7

Page 34: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

ALARM 166, ATEX ETR alarm batas frek.Konverter frekuensi telah beropeasi untuk lebih dari 60 d(di periode 600 detik) di bawah frekuensi minimum yangdiizinkan (parameter 1-98 ATEX ETR interpol. points freq.).

PERINGATAN 250, Suku cadang baruKomponen di drive telah diganti.

Pemecahan masalah• Reset sistem drive untuk mengembalikan operasi

normal.

PERINGATAN 251, Kode jenis baruKartu daya atau komponen lain telah diganti, dan kodejenis berubah.

Pemeliharaan, Diagnostik, d... VLT® AutomationDrive FC 301/302

32 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

77

Page 35: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

8 Spesifikasi

8.1 Data Kelistrikan

8.1.1 Sumber Listrik 200-240 V

Peruntukan tipe PK25 PK37 PK55 PK75 P1K1 P1K5 P2K2 P3K0 P3K7

Output poros tipikal [kW/(hp)], kelebihanbeban tinggi

0.25(0.34)

0.37(0.5)

0.55(0.75)

0.75(1.0)

1.1(1.5)

1.5(2.0)

2.2(3.0)

3.0(4.0)

3.7(5.0)

Rating proteksi penutup IP20 (FC 301 saja) A1 A1 A1 A1 A1 A1 – – –

Rating proteksi penutup IP20, IP21 A2 A2 A2 A2 A2 A2 A2 A3 A3

Rating proteksi penutup IP55, IP66 A4/A5 A4/A5 A4/A5 A4/A5 A4/A5 A4/A5 A4/A5 A5 A5

Arus output

Kontinu (200–240 V) [A] 1.8 2.4 3.5 4.6 6.6 7.5 10.6 12.5 16.7

Intermiten (200-240 V) [A] 2.9 3.8 5.6 7.4 10.6 12.0 17.0 20.0 26.7

Kontinu kVA (208 V) [kVA] 0.65 0.86 1.26 1.66 2.38 2.70 3.82 4.50 6.00

Arus input maksimum

Kontinu (200–240 V) [A] 1.6 2.2 3.2 4.1 5.9 6.8 9.5 11.3 15.0

Intermiten (200-240 V) [A] 2.6 3.5 5.1 6.6 9.4 10.9 15.2 18.1 24.0

Spesifikasi tambahan

Diameter maksimum2),5) kabel ke sumber listrik,motor, rem, dan pembagi beban

[mm2] ([AWG])

4, 4, 4 (12,12,12)(minimum 0.2 (24))

Diameter maksimum2),5) kabel ke pemutus

rangkaian [mm2] ([AWG])6, 4, 4 (10,12,12)

Perkiraan kehilangan daya rating beban

maksimum [W]3)21 29 42 54 63 82 116 155 185

Efisiensi4) 0.94 0.94 0.95 0.95 0.96 0.96 0.96 0.96 0.96

Tabel 8.1 Sumber Listrik 200-240 V, PK25–P3K7

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 33

8 8

Page 36: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Peruntukan tipe P5K5 P7K5 P11K

Kelebihan beban tinggi/normal1) HO NO HO NO HO NO

Output poros tipikal [kW/(hp)] 5.5 (7.5) 7.5 (10) 7.5 (10) 11 (15) 11 (15) 15 (20)

Rating proteksi penutup IP20 B3 B3 B4

Rating proteksi penutup IP21, IP55, IP66 B1 B1 B2

Arus output

Kontinu (200–240 V) [A] 24.2 30.8 30.8 46.2 46.2 59.4

Intermiten (60 d beban berlebih) (200–240 V) [A] 38.7 33.9 49.3 50.8 73.9 65.3

Kontinu kVA (208 V) [kVA] 8.7 11.1 11.1 16.6 16.6 21.4

Arus input maksimum

Kontinu (200–240 V) [A] 22.0 28.0 28.0 42.0 42.0 54.0

Intermiten (60 d beban berlebih) (200–240 V) [A] 35.2 30.8 44.8 46.2 67.2 59.4

Spesifikasi tambahan

IP20 diameter maksimum2),5) kabel ke sumber listrik, rem, motor,

dan pembagi beban [mm2] ([AWG])10, 10,- (8, 8,-) 10, 10,- (8, 8,-) 35,-,- (2,-,-)

IP21 diameter maksimum2),5) kabel ke sumber listrik, rem, dan

pembagi beban [mm2] ([AWG])16,10,16 (6, 8, 6) 16,10,16 (6, 8, 6) 35,-,- (2,-,-)

IP21 diameter maksimum2),5) kabel ke motor [mm2] ([AWG]) 10, 10,- (8, 8,-) 10, 10,- (8, 8,-) 35,25,25 (2, 4, 4)

Diameter maksimum2),5) kabel ke pemutus rangkaian

[mm2] ([AWG])16,10,10 (6, 8, 8)

Perkiraan kehilangan daya rating beban maksimum [W]3) 239 310 371 514 463 602

Efisiensi4) 0.96 0.96 0.96

Tabel 8.2 Sumber Listrik 200-240 V, P5K5–P11K

Peruntukan tipe P15K P18K P22K P30K P37K

Kelebihan beban tinggi/normal1) HO NO HO NO HO NO HO NO HO NO

Output poros tipikal [kW/(hp)]15

(20)18.5(25)

18.5(25)

22(30)

22(30)

30(40)

30(40)

37(50)

37(50)

45(60)

Rating proteksi penutup IP20 B4 C3 C3 C4 C4

Rating proteksi penutup IP21, IP55, IP66 C1 C1 C1 C2 C2

Arus output

Kontinu (200–240 V) [A] 59.4 74.8 74.8 88.0 88.0 115 115 143 143 170

Intermiten (60 d beban berlebih) (200–240 V) [A] 89.1 82.3 112 96.8 132 127 173 157 215 187

Kontinu kVA (208 V) [kVA] 21.4 26.9 26.9 31.7 31.7 41.4 41.4 51.5 51.5 61.2

Arus input maksimum

Kontinu (200–240 V) [A] 54.0 68.0 68.0 80.0 80.0 104 104 130 130 154

Intermiten (60 d beban berlebih) (200–240 V) [A] 81.0 74.8 102 88.0 120 114 156 143 195 169

Spesifikasi tambahan

IP20 diameter maksimum5) kabel ke sumberlistrik, rem, motor, dan pembagi beban

[mm2] ([AWG])

35 (2) 50 (1) 50 (1) 150 (300 MCM) 150 (300 MCM)

IP21, IP55, IP66 diameter maksimum5) kabel ke

sumber listrik dan motor [mm2] ([AWG])50 (1) 50 (1) 50 (1) 150 (300 MCM) 150 (300 MCM)

IP21, IP55, IP66 diameter maksimum5) kabel ke

rem dan pembagi beban [mm2] ([AWG])50 (1) 50 (1) 50 (1) 95 (3/0) 95 (3/0)

Diameter maksimum2),5) kabel ke pemutus

rangkaian [mm2] ([AWG])50, 35, 35 (1, 2, 2)

95, 70, 70(3/0, 2/0, 2/0)

185, 150, 120(350 MCM, 300

MCM, 4/0)

Perkiraan kehilangan daya rating beban

maksimum [W]3)624 737 740 845 874 1140 1143 1353 1400 1636

Efisiensi4) 0.96 0.97 0.97 0.97 0.97

Tabel 8.3 Sumber Listrik 200-240 V, P15K–P37K

Spesifikasi VLT® AutomationDrive FC 301/302

34 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 37: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

8.1.2 Catu Listrik 380–500 V AC

Peruntukan tipe PK37 PK55 PK75 P1K1 P1K5 P2K2 P3K0 P4K0 P5K5 P7K5

Output poros tipikal [kW/(hp)], kelebihan bebantinggi

0.37(0.5)

0.55(0.75)

0.75(1.0)

1.1(1.5)

1.5(2.0)

2.2(3.0)

3.0(4.0)

4.0(5.0)

5.5(7.5)

7.5(10)

Rating proteksi penutup IP20 (FC 301 saja) A1 A1 A1 A1 A1 – – – – –

Rating proteksi penutup IP20, IP21 A2 A2 A2 A2 A2 A2 A2 A2 A3 A3

Rating proteksi penutup IP55, IP66 A4/A5 A4/A5 A4/A5 A4/A5 A4/A5 A4/A5 A4/A5 A4/A5 A5 A5

Arus output kelebihan beban tinggi 160% untuk 1 menit

Output poros [kW/(hp)] 0.37(0.5)

0.55(0.75)

0.75(1.0)

1.1(1.5)

1.5(2.0)

2.2(3.0)

3.0(4.0)

4.0(5.0)

5.5(7.5)

7.5(10)

Kontinu (380–440 V) [A] 1.3 1.8 2.4 3.0 4.1 5.6 7.2 10 13 16

Intermiten (380–440 V) [A] 2.1 2.9 3.8 4.8 6.6 9.0 11.5 16 20.8 25.6

Kontinu (441–500 V) [A] 1.2 1.6 2.1 2.7 3.4 4.8 6.3 8.2 11 14.5

Intermiten (441–500 V) [A] 1.9 2.6 3.4 4.3 5.4 7.7 10.1 13.1 17.6 23.2

Kontinu kVA (400 V) [kVA] 0.9 1.3 1.7 2.1 2.8 3.9 5.0 6.9 9.0 11

Kontinu kVA (460 V) [kVA] 0.9 1.3 1.7 2.4 2.7 3.8 5.0 6.5 8.8 11.6

Arus input maksimum

Kontinu (380–440 V) [A] 1.2 1.6 2.2 2.7 3.7 5.0 6.5 9.0 11.7 14.4

Intermiten (380–440 V) [A] 1.9 2.6 3.5 4.3 5.9 8.0 10.4 14.4 18.7 23

Kontinu (441–500 V) [A] 1.0 1.4 1.9 2.7 3.1 4.3 5.7 7.4 9.9 13

Intermiten (441–500 V) [A] 1.6 2.2 3.0 4.3 5.0 6.9 9.1 11.8 15.8 20.8

Spesifikasi tambahan

IP20, IP21 diameter maksimum2),5) kabel kesumber listrik, rem, motor, dan pembagi beban

[mm2] ([AWG])

4, 4, 4 (12,12,12)(minimum 0.2(24))

IP55, IP66 diameter maksimum2),5) kabel kesumber listrik, motor, rem, dan pembagi beban

[mm2] ([AWG])

4, 4, 4 (12,12,12)

Diameter maksimum2),5) kabel ke pemutus

rangkaian [mm2] ([AWG])6, 4, 4 (10,12,12)

Perkiraan kehilangan daya rating beban

maksimum [W]3)35 42 46 58 62 88 116 124 187 255

Efisiensi4) 0.93 0.95 0.96 0.96 0.97 0.97 0.97 0.97 0.97 0.97

Tabel 8.4 Catu Listrik 380–500 V (FC 302), 380–480 V (FC 301), PK37–P7K5

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 35

8 8

Page 38: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Peruntukan tipe P11K P15K P18K P22K

Kelebihan beban tinggi/normal1) HO NO HO NO HO NO HO NO

Output poros tipikal [kW/(hp)] 11 (15) 15 (20) 15 (20) 18.5 (25) 18.5 (25) 22 (30) 22 (30) 30 (40)

Rating proteksi penutup IP20 B3 B3 B4 B4

Rating proteksi penutup IP21, IP55, IP66 B1 B1 B2 B2

Arus output

Kontinu (380–440 V) [A] 24 32 32 37.5 37.5 44 44 61

Intermiten (60 d beban berlebih)(380–440 V) [A]

38.4 35.2 51.2 41.3 60 48.4 70.4 67.1

Kontinu (441–500 V) [A] 21 27 27 34 34 40 40 52

Intermiten (60 d beban berlebih)(441–500 V) [A]

33.6 29.7 43.2 37.4 54.4 44 64 57.2

Kontinu kVA (400 V) [kVA] 16.6 22.2 22.2 26 26 30.5 30.5 42.3

Kontinu kVA (460 V) [kVA] – 21.5 – 27.1 – 31.9 – 41.4

Arus input maksimum

Kontinu (380–440 V) [A] 22 29 29 34 34 40 40 55

Intermiten (60 d beban berlebih)(380–440 V) [A]

35.2 31.9 46.4 37.4 54.4 44 64 60.5

Kontinu (441–500 V) [A] 19 25 25 31 31 36 36 47

Intermiten (60 d beban berlebih)(441–500 V) [A]

30.4 27.5 40 34.1 49.6 39.6 57.6 51.7

Spesifikasi tambahan

IP21, IP55, IP66 diameter maksimum2),5) kabelke sumber listrik, rem, dan pembagi beban

[mm2] ([AWG])

16, 10, 16 (6, 8, 6) 16, 10, 16 (6, 8, 6) 35,-,-(2,-,-) 35,-,-(2,-,-)

IP21, IP55, IP66 diameter maksimum2),5) kabel

ke motor [mm2] ([AWG])10, 10,- (8, 8,-) 10, 10,- (8, 8,-) 35, 25, 25 (2, 4, 4) 35, 25, 25 (2, 4, 4)

IP20 diameter maksimum2),5) kabel ke sumberlistrik, rem, motor, dan pembagi beban

[mm2] ([AWG])

10, 10,- (8, 8,-) 10, 10,- (8, 8,-) 35,-,-(2,-,-) 35,-,-(2,-,-)

Diameter maksimum2),5) kabel ke pemutus

rangkaian [mm2] ([AWG])16, 10, 10 (6, 8, 8)

Perkiraan kehilangan daya rating beban

maksimum [W]3)291 392 379 465 444 525 547 739

Efisiensi4) 0.98 0.98 0.98 0.98

Tabel 8.5 Catu Listrik 380–500 V (FC 302), 380–480 V (FC 301), P11K–P22K

Spesifikasi VLT® AutomationDrive FC 301/302

36 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 39: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Peruntukan tipe P30K P37K P45K P55K P75K

Kelebihan beban tinggi/normal1) HO NO HO NO HO NO HO NO HO NO

Output poros tipikal [kW/(hp)] 30 (40) 37 (50) 37 (50) 45 (60) 45 (60) 55 (75) 55 (75) 75 (100) 75 (100) 90 (125)

Rating proteksi penutup IP20 B4 C3 C3 C4 C4

Rating proteksi penutup IP21, IP55,IP66

C1 C1 C1 C2 C2

Arus output

Kontinu (380–440 V) [A] 61 73 73 90 90 106 106 147 147 177

Intermiten (60 d beban berlebih)(380–440 V) [A]

91.5 80.3 110 99 135 117 159 162 221 195

Kontinu (441–500 V) [A] 52 65 65 80 80 105 105 130 130 160

Intermiten (60 d beban berlebih)(441–500 V) [A]

78 71.5 97.5 88 120 116 158 143 195 176

Kontinu kVA (400 V) [kVA] 42.3 50.6 50.6 62.4 62.4 73.4 73.4 102 102 123

Kontinu kVA (460 V) [kVA] – 51.8 – 63.7 – 83.7 – 104 – 128

Arus input maksimum

Kontinu (380–440 V) [A] 55 66 66 82 82 96 96 133 133 161

Intermiten (60 d beban berlebih)(380–440 V) [A]

82.5 72.6 99 90.2 123 106 144 146 200 177

Kontinu (441–500 V) [A] 47 59 59 73 73 95 95 118 118 145

Intermiten (60 d beban berlebih)(441–500 V) [A]

70.5 64.9 88.5 80.3 110 105 143 130 177 160

Spesifikasi tambahan

IP20 diameter maksimum5) kabelke sumber listrik dan motor

[mm2] ([AWG])

35 (2) 50 (1) 50 (1) 150 (300 MCM) 150 (300 MCM)

IP20 diameter maksimum5) kabelke rem dan pembagi beban

[mm2] ([AWG])

35 (2) 50 (1) 50 (1) 95 (4/0) 95 (4/0)

IP21, IP55, IP66 diameter

maksimum5) kabel ke sumber listrik

dan motor [mm2] ([AWG])

50 (1) 50 (1) 50 (1) 150 (300 MCM) 150 (300 MCM)

IP21, IP55, IP66 diameter

maksimum5) kabel ke rem dan

pembagi beban [mm2] ([AWG])

50 (1) 50 (1) 50 (1) 95 (3/0) 95 (3/0)

Diameter maksimum2),5) kabel ke

pemutus rangkaian [mm2] ([AWG])50, 35, 35

(1, 2, 2)95, 70, 70

(3/0, 2/0, 2/0)

185, 150, 120(350 MCM, 300

MCM, 4/0)

Perkiraan kehilangan dayapada rating beban maksimum

[W]3)

570 698 697 843 891 1083 1022 1384 1232 1474

Efisiensi4) 0.98 0.98 0.98 0.98 0.99

Tabel 8.6 Catu Listrik 380–500 V (FC 302), 380–480 V (FC 301), P30K–P75K

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 37

8 8

Page 40: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

8.1.3 Catu Listrik 525–600 V (FC 302 saja)

Peruntukan tipe PK75 P1K1 P1K5 P2K2 P3K0 P4K0 P5K5 P7K5

Output poros tipikal [kW/(hp)] 0.75 (1) 1.1 (1.5) 1.5 (2.0) 2.2 (3.0) 3 (4.0) 4 (5.0) 5.5 (7.5) 7.5 (10)

Rating proteksi penutup IP20, IP21 A3 A3 A3 A3 A3 A3 A3 A3

Rating proteksi penutup IP55 A5 A5 A5 A5 A5 A5 A5 A5

Arus output

Kontinu (525–550 V) [A] 1.8 2.6 2.9 4.1 5.2 6.4 9.5 11.5

Intermiten (525–550 V) [A] 2.9 4.2 4.6 6.6 8.3 10.2 15.2 18.4

Kontinu (551–600 V) [A] 1.7 2.4 2.7 3.9 4.9 6.1 9.0 11.0

Intermiten (551–600 V) [A] 2.7 3.8 4.3 6.2 7.8 9.8 14.4 17.6

Kontinu kVA (525 V) [kVA] 1.7 2.5 2.8 3.9 5.0 6.1 9.0 11.0

Kontinu kVA (575 V) [kVA] 1.7 2.4 2.7 3.9 4.9 6.1 9.0 11.0

Arus input maksimum

Kontinu (525–600 V) [A] 1.7 2.4 2.7 4.1 5.2 5.8 8.6 10.4

Intermiten (525–600 V) [A] 2.7 3.8 4.3 6.6 8.3 9.3 13.8 16.6

Spesifikasi tambahan

Diameter maksimum2),5) kabel ke sumber listrik,

motor, rem, dan pembagi beban [mm2] ([AWG])

4, 4, 4 (12,12,12)(minimum 0.2 (24))

Diameter maksimum2),5) kabel ke pemutus

rangkaian [mm2] ([AWG])6, 4, 4 (10,12,12)

Perkiraan kehilangan daya rating beban

maksimum [W]3)35 50 65 92 122 145 195 261

Efisiensi4) 0.97 0.97 0.97 0.97 0.97 0.97 0.97 0.97

Tabel 8.7 Catu Listrik 525–600 V (FC 302 saja), PK75–P7K5

Spesifikasi VLT® AutomationDrive FC 301/302

38 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 41: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Peruntukan tipe P11K P15K P18K P22K P30K

Beban tinggi/normal1) HO NO HO NO HO NO HO NO HO NO

Output poros tipikal [kW/(hp)] 11 (15) 15 (20) 15 (20) 18.5 (25) 18.5 (25) 22 (30) 22 (30) 30 (40) 30 (40) 37 (50)

Rating proteksi penutup IP20 B3 B3 B4 B4 B4

Rating proteksi penutup IP21, IP55,IP66

B1 B1 B2 B2 C1

Arus output

Kontinu (525–550 V) [A] 19 23 23 28 28 36 36 43 43 54

Intermiten (525–550 V) [A] 30 25 37 31 45 40 58 47 65 59

Kontinu (551–600 V) [A] 18 22 22 27 27 34 34 41 41 52

Intermiten (551–600 V) [A] 29 24 35 30 43 37 54 45 62 57

Kontinu kVA (550 V) [kVA] 18.1 21.9 21.9 26.7 26.7 34.3 34.3 41.0 41.0 51.4

Kontinu kVA (575 V) [kVA] 17.9 21.9 21.9 26.9 26.9 33.9 33.9 40.8 40.8 51.8

Arus input maksimum

Kontinu pada 550 V [A] 17.2 20.9 20.9 25.4 25.4 32.7 32.7 39 39 49

Intermiten pada 550 V [A] 28 23 33 28 41 36 52 43 59 54

Kontinu pada 575 V [A] 16 20 20 24 24 31 31 37 37 47

Intermiten pada 575 V [A] 26 22 32 27 39 34 50 41 56 52

Spesifikasi tambahan

IP20 diameter maksimum2),5) kabelke sumber listrik, rem, motor, dan

pembagi beban [mm2] ([AWG])

10, 10,- (8, 8,-) 10, 10,- (8, 8,-) 35,-,-(2,-,-) 35,-,-(2,-,-) 35,-,-(2,-,-)

IP21, IP55, IP66 diameter

maksimum2),5) kabel ke sumberlistrik, rem, dan pembagi beban

[mm2] ([AWG])

16, 10, 10 (6, 8, 8) 16, 10, 10 (6, 8, 8) 35,-,-(2,-,-) 35,-,-(2,-,-) 50,-,- (1,-,-)

IP21, IP55, IP66 diameter

maksimum2),5) kabel ke motor

[mm2] ([AWG])

10, 10,- (8, 8,-) 10, 10,- (8, 8,-) 35, 25, 25 (2, 4, 4) 35, 25, 25 (2, 4, 4) 50,-,- (1,-,-)

Diameter maksimum2),5) kabel ke

pemutus rangkaian [mm2] ([AWG])

16, 10, 10(6, 8, 8)

50, 35, 35(1, 2, 2)

Perkiraan kehilangan daya

pada rating beban maksimum [W]3)220 300 300 370 370 440 440 600 600 740

Efisiensi4) 0.98 0.98 0.98 0.98 0.98

Tabel 8.8 Catu Listrik 525–600 V (FC 302 saja), P11K–P30K

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 39

8 8

Page 42: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Peruntukan tipe P37K P45K P55K P75K

Beban tinggi/normal1) HO NO HO NO HO NO HO NO

Output poros tipikal [kW/(hp)] 37 (50) 45 (60) 45 (60) 55 (75) 55 (75) 75 (100) 75 (100) 90 (125)

Rating proteksi penutup IP20 C3 C3 C3 C4 C4

Rating proteksi penutup IP21, IP55, IP66 C1 C1 C1 C2 C2

Arus output

Kontinu (525–550 V) [A] 54 65 65 87 87 105 105 137

Intermiten (525–550 V) [A] 81 72 98 96 131 116 158 151

Kontinu (551–600 V) [A] 52 62 62 83 83 100 100 131

Intermiten (551–600 V) [A] 78 68 93 91 125 110 150 144

Kontinu kVA (550 V) [kVA] 51.4 61.9 61.9 82.9 82.9 100.0 100.0 130.5

Kontinu kVA (575 V) [kVA] 51.8 61.7 61.7 82.7 82.7 99.6 99.6 130.5

Arus input maksimum

Kontinu pada 550 V [A] 49 59 59 78.9 78.9 95.3 95.3 124.3

Intermiten pada 550 V [A] 74 65 89 87 118 105 143 137

Kontinu pada 575 V [A] 47 56 56 75 75 91 91 119

Intermiten pada 575 V [A] 70 62 85 83 113 100 137 131

Spesifikasi tambahan

IP20 diameter maksimum5) kabel ke sumber listrik dan

motor [mm2] ([AWG])50 (1) 150 (300 MCM)

IP20 diameter maksimum5) kabel ke rem dan pembagi

beban [mm2] ([AWG])50 (1) 95 (4/0)

IP21, IP55, IP66 diameter maksimum5) kabel ke sumber

listrik dan motor [mm2] ([AWG])50 (1) 150 (300 MCM)

IP21, IP55, IP66 diameter maksimum5) kabel ke rem

dan pembagi beban [mm2] ([AWG])50 (1) 95 (4/0)

Diameter maksimum2),5) kabel ke pemutus rangkaian

[mm2] ([AWG])50, 35, 35

(1, 2, 2)95, 70, 70

(3/0, 2/0, 2/0)

185, 150, 120(350 MCM, 300

MCM, 4/0)

Perkiraan kehilangan daya rating beban maksimum

[W]3)740 900 900 1100 1100 1500 1500 1800

Efisiensi4) 0.98 0.98 0.98 0.98

Tabel 8.9 Catu Listrik 525–600 V P37K–P75K (FC 302 saja), P37K–P75K

Untuk rating sekering, lihat bab 8.7 Sekering dan Pemutus Rangkaian.1) Kelebihan beban tinggi=150% atau 160% torsi untuk lama dari 60 d. Kelebihan beban Normal=110% torsi untuk lama dari 60 d.2) Ke 3 nilai untuk diameter kabel maksimum adalah untuk kabel satu inti, kabel fleksibel, dan kabel fleksibel dengan lengan.3) Berlaku untuk mengukur dimensi pendingin konverter frekuensi. Jika frekuensi penyalaan lebih tinggi daripada pengaturan standar, kehilangandaya dapat meningkat. Konsumsi daya LCP dan kartu kontrol tipikal termasuk. Untuk data kehilangan daya menurut EN 50598-2, lihatdrives.danfoss.com/knowledge-center/energy-efficiency-directive/#/4) Efisiensi diukur pada arus nominal. Untuk kelas efisiensi energi, lihat bab 8.4 Kondisi Lingkungan. Untuk kehilangan beban bagian, lihatdrives.danfoss.com/knowledge-center/energy-efficiency-directive/#/.5) Pertimbangkan diameter kabel tembaga.

Spesifikasi VLT® AutomationDrive FC 301/302

40 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 43: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

8.1.4 Catu Listrik 525–690 V (FC 302 saja)

Peruntukan tipe P1K1 P1K5 P2K2 P3K0 P4K0 P5K5 P7K5

Kelebihan beban tinggi/normal1) HO/NO HO/NO HO/NO HO/NO HO/NO HO/NO HO/NO

Output poros tipikal [kW/(hp)] 1.1 (1.5) 1.5 (2.0) 2.2 (3.0) 3.0 (4.0) 4.0 (5.0) 5.5 (7.5) 7.5 (10)

Rating proteksi penutup IP20 A3 A3 A3 A3 A3 A3 A3

Arus output

Kontinu (525–550 V) [A] 2.1 2.7 3.9 4.9 6.1 9.0 11.0

Intermiten (525–550 V) [A] 3.4 4.3 6.2 7.8 9.8 14.4 17.6

Kontinu (551–690 V) [A] 1.6 2.2 3.2 4.5 5.5 7.5 10.0

Intermiten (551–690 V) [A] 2.6 3.5 5.1 7.2 8.8 12.0 16.0

Kontinu kVA 525 V [kVA] 1.9 2.5 3.5 4.5 5.5 8.2 10.0

Kontinu kVA 690 V [kVA] 1.9 2.6 3.8 5.4 6.6 9.0 12.0

Arus input maksimum

Kontinu (525–550 V) [A] 1.9 2.4 3.5 4.4 5.5 8.1 9.9

Intermiten (525–550 V) [A] 3.0 3.9 5.6 7.0 8.8 12.9 15.8

Kontinu (551–690 V) [A] 1.4 2.0 2.9 4.0 4.9 6.7 9.0

Intermiten (551–690 V) [A] 2.3 3.2 4.6 6.5 7.9 10.8 14.4

Spesifikasi tambahan

Diameter maksimum2),5) kabel ke sumber listrik, motor,

rem, dan pembagi beban [mm2] ([AWG])4, 4, 4 (12, 12, 12) (minimum 0.2 (24)

Diameter maksimum2),5) kabel ke pemutus rangkaian

[mm2] ([AWG])6, 4, 4 (10, 12, 12)

Perkiraan kehilangan daya pada rating beban

maksimum [W]3) 44 60 88 120 160 220 300

Efisiensi4) 0.96 0.96 0.96 0.96 0.96 0.96 0.96

Tabel 8.10 A3 Penutup, Catu Listrik 525–690 V IP20/Proteksi Sasis, P1K1–P7K5

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 41

8 8

Page 44: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Peruntukan tipe P11K P15K P18K P22K

Kelebihan beban tinggi/normal1) HO NO HO NO HO NO HO NO

Output poros tipikal pada 550 V [kW/(hp)] 7.5(10)

11(15)

11(15)

15(20)

15(20)

18.5(25)

18.5(25)

22(30)

Output poros tipikal pada 690 V [kW/(hp)] 11(15)

15(20)

15(20)

18.5(25)

18.5(25)

22(30)

22(30)

30(40)

Rating proteksi penutup IP20 B4 B4 B4 B4

Rating proteksi penutup IP21, IP55 B2 B2 B2 B2

Arus output

Kontinu (525–550 V) [A] 14.0 19.0 19.0 23.0 23.0 28.0 28.0 36.0

Intermiten (60 d beban berlebih) (525–550 V) [A] 22.4 20.9 30.4 25.3 36.8 30.8 44.8 39.6

Kontinu (551–690 V) [A] 13.0 18.0 18.0 22.0 22.0 27.0 27.0 34.0

Intermiten (60 d beban berlebih) (551–690 V) [A] 20.8 19.8 28.8 24.2 35.2 29.7 43.2 37.4

Kontinu kVA (pada 550 V) [kVA] 13.3 18.1 18.1 21.9 21.9 26.7 26.7 34.3

Kontinu kVA (pada 690 V) [kVA] 15.5 21.5 21.5 26.3 26.3 32.3 32.3 40.6

Arus input maksimum

Kontinu (pada 550 V) [A] 15.0 19.5 19.5 24.0 24.0 29.0 29.0 36.0

Intermiten (60 d beban berlebih) (pada 550 V) [A] 23.2 21.5 31.2 26.4 38.4 31.9 46.4 39.6

Kontinu (pada 690 V) [A] 14.5 19.5 19.5 24.0 24.0 29.0 29.0 36.0

Intermiten (60 d beban berlebih) (pada 690 V) [A] 23.2 21.5 31.2 26.4 38.4 31.9 46.4 39.6

Spesifikasi tambahan

Diameter maksimum2),5) kabel ke sumber listrik/

motor, pembagi beban, dan rem [mm2] ([AWG])35, 25, 25 (2, 4, 4)

Diameter maksimum2),5) kabel ke pemutus

rangkaian [mm2] ([AWG])16, 10, 10 (6, 8, 8)

Perkiraan kehilangan daya pada rating beban

maksimum [W]3)150 220 220 300 300 370 370 440

Efisiensi4) 0.98 0.98 0.98 0.98

Tabel 8.11 B2/B4 Penutup, Catu Listrik 525–690 V IP20/IP21/IP55 - Sasis/NEMA 1/NEMA 12 (FC 302 saja), P11K–P22K

Spesifikasi VLT® AutomationDrive FC 301/302

42 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 45: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Peruntukan tipe P30K P37K P45K P55K P75K

Kelebihan beban tinggi/normal1) HO NO HO NO HO NO HO NO HO NO

Output poros tipikal pada 550 V [kW/(hp)] 22(30)

30(40)

30(40)

37(50)

37(50)

45(60)

45(60)

55(75)

55(75)

75(100)

Output poros tipikal pada 690 V [kW/(hp)] 30(40)

37(50)

37(50)

45(60)

45(60)

55(75)

55(75)

75(100)

75(100)

90(125)

Rating proteksi penutup IP20 B4 C3 C3 D3h D3h

Rating proteksi penutup IP21, IP55 C2 C2 C2 C2 C2

Arus output

Kontinu (525–550 V) [A] 36.0 43.0 43.0 54.0 54.0 65.0 65.0 87.0 87.0 105

Intermiten (60 d beban berlebih)(525–550 V) [A] 54.0 47.3 64.5 59.4 81.0 71.5 97.5 95.7 130.5 115.5

Kontinu (551–690 V) [A] 34.0 41.0 41.0 52.0 52.0 62.0 62.0 83.0 83.0 100

Intermiten (60 d beban berlebih)(551–690 V) [A] 51.0 45.1 61.5 57.2 78.0 68.2 93.0 91.3 124.5 110

Kontinu kVA (pada 550 V) [kVA] 34.3 41.0 41.0 51.4 51.4 61.9 61.9 82.9 82.9 100

Kontinu kVA (pada 690 V) [kVA] 40.6 49.0 49.0 62.1 62.1 74.1 74.1 99.2 99.2 119.5

Arus input maksimum

Kontinu (pada 550 V) [A] 36.0 49.0 49.0 59.0 59.0 71.0 71.0 87.0 87.0 99.0

Intermiten (60 d beban berlebih)(pada 550 V) [A] 54.0 53.9 72.0 64.9 87.0 78.1 105.0 95.7 129 108.9

Kontinu (pada 690 V) [A] 36.0 48.0 48.0 58.0 58.0 70.0 70.0 86.0 – –

Intermiten (60 d beban berlebih)(pada 690 V) [A] 54.0 52.8 72.0 63.8 87.0 77.0 105 94.6 – –

Spesifikasi tambahan

Diameter maksimum5) kabel ke sumber

listrik dan motor [mm2] ([AWG])150 (300 MCM)

Diameter maksimum5) kabel ke pembagi

beban, dan rem [mm2] ([AWG])95 (3/0)

Diameter maksimum2),5) kabel ke pemutus

rangkaian [mm2] ([AWG])

95, 70, 70(3/0, 2/0, 2/0)

185, 150, 120(350 MCM, 300

MCM, 4/0)–

Perkiraan kehilangan daya

pada rating beban maksimum [W]3)600 740 740 900 900 1100 1100 1500 1500 1800

Efisiensi4) 0.98 0.98 0.98 0.98 0.98

Tabel 8.12 B4, C2, C3 Penutup, Catu Listrik 525–690 V IP20/IP21/IP55 – Sasis/NEMA1/NEMA 12 (FC 302 saja), P30K–P75K

Untuk rating sekering, lihat bab 8.7 Sekering dan Pemutus Rangkaian.1) Kelebihan beban tinggi=150% atau 160% torsi untuk lama dari 60 d. Kelebihan beban Normal=110% torsi untuk lama dari 60 d.2) Ke 3 nilai untuk diameter kabel maksimum adalah untuk kabel satu inti, kabel fleksibel, dan kabel fleksibel dengan lengan.3) Berlaku untuk mengukur dimensi pendingin konverter frekuensi. Jika frekuensi penyalaan lebih tinggi daripada pengaturan standar, kehilangandaya dapat meningkat. Konsumsi daya LCP dan kartu kontrol tipikal termasuk. Untuk data kehilangan daya menurut EN 50598-2, lihatdrives.danfoss.com/knowledge-center/energy-efficiency-directive/#/4) Efisiensi diukur pada arus nominal. Untuk kelas efisiensi energi, lihat bab 8.4 Kondisi Lingkungan. Untuk kehilangan beban bagian, lihatdrives.danfoss.com/knowledge-center/energy-efficiency-directive/#/.5) Pertimbangkan diameter kabel tembaga.

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 43

8 8

Page 46: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

8.2 Catu Listrik

Mains supply (Catu Listrik)Terminal catu (6 denyut) L1, L2, L3Terminal catu (12 denyut) L1-1, L2-1, L3-1, L1-2, L2-2, L3-2Voltase catu 200–240 V ±10%Voltase catu FC 301: 380–480 V/FC 302: 380–500 V ±10%Voltase catu FC 302: 525–600 V ±10%Voltase catu FC 302: 525–690 V ±10%

Voltase sumber listrik rendah/anjlok:Selama voltase sumber listrik rendah atau anjlok, konverter akan tetap beroperasi sampai voltase DC-link anjlok di bawah levelberhenti minimum, atau umumnya 15% di bawah rating voltase catu terendah konverter. Penyalaan dan torsi penuh tidakdapat diharapkan saat voltase sumber listrik kurang dari 10% di bawah rating voltase catu terendah konverter frekuensi.

Frekuensi catu 50/60 Hz ±5%Ketidakseimbangan sementara maks antara fasa-fasa sumber listrik 3.0% rating voltase catuFaktor daya sejati (λ) ≥0.9 nominal pada rating bebanFaktor daya pergeseran (cos ϕ) Mendekati satu (>0.98)Menghidupkan catu input L1, L2, L3 (penyalaan) ≤7.5 kW (10 hp) Maksimum dua kali per menit.Menghidupkan catu input L1, L2, L3 (penyalaan) 11–75 kW (15–101 hp) Maksimum satu kali per menit.Menghidupkan catu input L1, L2, L3 (penyalaan) ≥90 kW (121 hp) Maksimum satu kali per 2 menit.Lingkungan menurut EN60664-1 Over voltase kategori III/tingkat polusi 2

Unit ini cocok digunakan pada rangkaian yang mampu menghasilkan tidak lebih dari 100000 RMS Ampere simetris,240/500/600/690 V maksimum.

8.3 Output Motor dan Data Motor

Output motor (U, V, W)Voltase output 0–100% voltase catuFrekuensi output 0–590 Hz1)

Frekuensi output pada mode fluks 0–300 HzOutput saat penyalaan Tak terbatasWaktu akselerasi/deselerasi 0.01–3600 s

1) Tergantung voltase dan daya.

Karakteristik torsiTorsi awal (torsi konstan) Maksimum 160% untuk 60 d1) sekali dalam 10 menitTorsi awal/kelebihan beban (torsi variabel) Maksimum 110% hingga 0.5 s1) sekali dalam 10 menitWaktu peningkatan torsi di flux (untuk 5 kHz fsw) 1 msWaktu peningkatan torsi di VVC+ (tersendiri dari f fsw) 10 ms

1) Persentase berkaitan dengan torsi nominal.

Spesifikasi VLT® AutomationDrive FC 301/302

44 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 47: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

8.4 Kondisi Lingkungan

LingkunganPenutup IP20/Sasis, IP21/Jenis 1, IP55/Jenis 12, IP66/Jenis 4XUji getaran 1.0 gTHDv maksimum 10%Kelembapan relatif maksimum 5–93% (IEC 721-3-3; Kelas 3K3 (tidak mengembun) sewaktu pengoperasianUji H2S (IEC 60068-2-43) lingkungan agresif Kelas KdSuhu lingkungan1) Maksimum 50 °C (122 °F) (24-jam-maksimum rata-rata 45 °C (113 °F))Suhu lingkungan minimum selama pengoperasian penuh 0 °C (32 °F)Suhu lingkungan minimum selama pengurangan performa -10 °C (14 °F)Suhu selama penyimpanan/transportasi -25 to +65/70 °C (-13 to +149/158 °F)Ketinggian maksimum di atas permukaan laut tanpa penurunan1) 1000 m (3280 kaki)Standar EMC, Emisi EN 61800-3Standar EMC, Imunitas EN 61800-3Kelas efisiensi energi2) IE2

1) Lihat kondisi khusus dalam panduan perancangan, untuk:

• Penurunan rating saat suhu lingkungan tinggi.

• Penurunan rating untuk tempat berelevasi tinggi.

2) Ditentukan menurut EN 50598-2 di:

• Rating beban.

• 90% rating frekuensi.

• Pengaturan pabrik frekuensi penyalaan.

• Pengaturan pabrik pola penyalaan.

8.5 Spesifikasi Kabel

Panjang kabel dan diameter kabel kontrol1)

Panjang maksimum kabel motor, berpelindung FC 301: 50 m (164 kaki)/FC 302: 150 m (492 kaki)Panjang maksimum kabel motor, tanpa pelindung FC 301: 75 m (246 kaki/FC 302: 300 m (984 kaki)Diameter maksimum ke terminal kontrol, kabel fleksibel/kaku tanpa lengan ujung kabel 1.5 mm2/16 AWGDiameter maksimum ke terminal kontrol, kabel fleksibel dengan lengan ujung kabel 1 mm2/18 AWGDiameter maksimum ke terminal kontrol, kabel fleksibel dengan lengan ujung kabel dan kerah 0.5 mm2/20 AWGDiameter minimum ke terminal kontrol 0.25 mm2/24 AWG

1) Untuk kabel daya, lihat tabel kelistrikan di bab 8.1 Data Kelistrikan.

8.6 Kontrol Input/Output dan Data Kontrol

Input digitalInput digital terprogram FC 301: 4 (5)1)/FC 302: 4 (6)1)

Nomor terminal 18, 19, 271), 291), 32, 33Logik PNP atau NPNLevel voltase 0–24 V DCLevel voltase, Logik 0 PNP <5 V DCLevel voltase, logik 1 PNP >10 V DCLevel voltase, logik 0 NPN2) >19 V DCLevel voltase, logik 1 NPN2) <14 V DCVoltase maksimum pada input 28 V DCRentang frekuensi denyut 0–110 kHz(Siklus tugas) lebar denyut minimum 4.5 msResistansi input, Ri Sekitar 4 kΩ

1) Terminal 27 dan 29 juga dapat diprogram sebagai output.

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 45

8 8

Page 48: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

2) Kecuali terminan input 37 STO.

STO terminal 371, 2) (terminal 37 adalah logik PNP tetap)Level voltase 0–24 V DCLevel voltase, Logik 0 PNP <4 V DCLevel voltase, logik 1 PNP >20 V DCVoltase maksimum pada input 28 V DCArus input tipikal pada 24 V 50 mA rmsArus input tipikal pada 20 V 60 mA rmsKapasitansi input 400 nF

Semua input digital diisolasi secara galvanis dari voltase catu (PELV) dan terminal voltase tinggi lainnya.1) Lihat bab 4.7.1 Safe Torque Off (STO) untuk informasi lebih lanjut tentang terminal 37 dan STO.2) Jika menggunakan kontaktor dengan kumparan DC yang dikombinasikan dengan STO, sediakan jalur kembali untuk arusdari kumparan saat konverter dimatikan. Ini dapat dilakukan menggunakan dioda freewheel (atau, 30 V atau 50 V MOV responsyang lebih cepat) di seluruh kumparan. Kontaktor tipikal dapat dibeli bersama dioda ini.

Input analogJumlah input analog 2Nomor terminal 53, 54Mode Voltase atau arus.Pemilihan mode Sakelar S201 dan sakelar S202Mode voltase Sakelar S201/sakelar S202 = OFF (U)Level voltase -10 V to +10 V (terskala)Resistansi input, Ri Kira-kira 10 kΩVoltase maksimum ±20 VMode arus Sakelar S201/sakelar S202 = ON (I)Level arus 0/4 hingga 20 mA (terskala)Resistansi input, Ri Kira-kira 200 ΩArus maksimum 30 mAResolusi untuk input analog 10 bit (tanda +)Akurasi input analog Kesalahan maksimum 0.5% dari skala penuhLebar pita 100 Hz

Semua input analog diisolasi secara galvanis dari voltase catu (PELV) dan terminal voltase tinggi lainnya.

Ilustrasi 8.1 Isolasi PELV

Input denyut/enkoderInput denyut/enkoder terprogram 2/1Denyut/enkoder nomor terminal 291), 332)/323), 333)

Frekuensi maksimum pada terminal 29, 32, 33 110 kHz (Mekanisme dorong-tarik)Frekuensi maksimum pada terminal 29, 32, 33 5 kHz (Kolektor terbuka)Frekuensi minimum pada terminal 29, 32, 33 4 HzLevel voltase Lihat grup parameter 5-1* Digital Input dalam panduan pemrograman.Voltase maksimum pada input 28 V DCResistansi input, Ri Sekitar 4 kΩAkurasi input denyut (0.1–1 kHz) Kesalahan maksimum: 0.1% dari skala penuh

Spesifikasi VLT® AutomationDrive FC 301/302

46 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 49: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Akurasi input enkoder (1–11 kHz) Kesalahan maksimum: 0.05% dari skala penuh

Semua input denyut dan enkoder (terminal 29, 32, 33) diisolasi secara galvanis dari voltase catu (PELV) dan terminal voltasetinggi lainnya.1) FC 302 saja.2) Input denyut adalah 29 dan 33.3) Input enkoder: 32=A, 33=B.

Digital outputOutput digital/denyut terprogram 2Nomor terminal 27, 291)

Level voltase pada output digital/frekuensi 0–24 VArus output maksimum (masuk atau keluar) 40 mABeban maksimum pada output frekuensi 1 kΩBeban kapasitif maksimum pada output frekuensi 10 nFFrekuensi output minimum pada output frekuensi 0 HzFrekuensi output maksimum pada output frekuensi 32 kHzAkurasi output frekuensi Kesalahan maksimum: 0.1% dari skala penuhResolusi output frekuensi 12 bit

1) Terminal 27 dan 29 juga dapat diprogram sebagai input.Output digital diisolasi secara galvanis dari voltase catu (PELV) dan terminal voltase tinggi lainnya.

Output analogJumlah output analog terprogram 1Nomor terminal 42Rentang arus pada output analog 0/4 hingga 20 mAMaksimum beban GND–output analog kurang dari 500 ΩAkurasi output analog Kesalahan maksimum: 0.5% dari skala penuhResolusi pada output analog 12 bit

Input analog diisolasi secara galvanis dari voltase catu (PELV) dan terminal voltase tinggi lainnya.

Kartu Kontrol, output 24 V DCNomor terminal 12, 13Voltase output 24 V +1, -3 VBeban maksimum 200 mA

Catu 24 V DC diisolasi secara galvanis dari voltase catu (PELV), tetapi memiliki potensi yang sama sebagai input dan outputanalog maupun digital.

Kartu Kontrol, keluaran 10 V DCNomor terminal ±50Voltase output 10.5 V ±0.5 VBeban maksimum 15 mA

Catu 10 V DC diisolasi secara galvanis dari voltase catu (PELV) dan terminal voltase tinggi lainnya.

Kartu kontrol, Komunikasi Seri RS485Nomor terminal 68 (P, TX+, RX+), 69 (N, TX-, RX-)Nomor terminal 61 Bersama untuk terminal 68 dan 69

Rangkaian komunikasi seri RS485 secara fungsional terpisah dari sirkuit pusat lainnya dan diisolasi secara galvanis dari voltasecatu (PELV).

Kartu kontrol, komunikasi seri USBStandar USB 1.1 (kecepatan penuh)Colokan USB Colokan USB jenis B

Koneksi ke PC dilakukan melalui kabel USB host/perangkat standar.Koneksi USB diisolasi secara galvanis dari voltase catu (PELV) dan terminal voltase tinggi lainnya.Koneksi USB tidak diisolasi secara galvanis dari proteksi pembumian. Gunakan laptop terisolasi sebagai koneksi PC ke konektorUSB pada konverter frekuensi saja.

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 47

8 8

Page 50: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Output relaiOutput relai terprogram FC 301 semua kW: 1/FC 302 semua kW: 2Nomor terminal relai 01 1–3 (break), 1–2 (sambung)Beban terminal maksimum (AC-1)1) on 1–3 (NC), 1–2 (NO) (beban resistif ) 240 V AC, 2 ABeban terminal maksimum (AC-15)1) (Beban induktif @ cosφ 0.4) 240 V AC, 0.2 ABeban terminal maksimum (DC-1)1) on 1–2 (NO), 1–3 (NC) (Beban resistif ) 60 V DC, 1 ABeban terminal maksimum (DC-13)1) (beban induktif ) 24 V DC, 0.1 ARelai 02 (FC 302 saja) nomor terminal 4–6 (break), 4–5 (sambung)Beban terminal maksimum (AC-1)1) pada 4–5 (NO) (beban resistif )2),3) over voltase kategori II 400 V AC, 2 ABeban terminal maksimum (AC-15)1) pada 4–5 (NO) (Beban induktif @ cosφ 0.4) 240 V AC, 0.2 ABeban terminal maksimum (DC-1)1) pada 4–5 (NO) (beban resistif ) 80 V DC, 2 ABeban terminal maksimum (DC-13)1) pada 4–5 (NO) (beban induktif ) 24 V DC, 0.1 ABeban terminal maks. (AC-1)1) pada 4–6 (NC) (beban resistif ) 240 V AC, 2 ABeban terminal maksimum (AC-15)1) pada 4–6 (NC) (Beban induktif @ cosφ 0.4) 240 V AC, 0.2 ABeban terminal maksimum (DC-1)1) pada 4–6 (NC) (beban resistif ) 50 V DC, 2 ABeban terminal maks. (DC-13)1) pada 4–6 (NC) (beban induktif ) 24 V DC, 0.1 ABeban terminal min. pada 1-3 (NC), 1-2 (NO), 4-6 (NC), 4-5 (NO) 24 V DC 1 mA, 24 V AC 20 mALingkungan menurut EN 60664-1 Over voltase kategori III/tingkat polusi 2

1) IEC 60947 bagian 4 dan 5Kontak relai diisolasi secara galvanis dari rangkaian lainnya dengan isolasi berpenguat (PELV).2) Kelebihan Voltase Kategori II.3) Aplikasi UL 300 V AC 2 A.

Performa kartu kontrolInterval pindai 1 ms

Karakteristik kontrolResolusi frekuensi output pada 0-590 Hz ±0.003 HzAkurasi perulangan start/stop presisi (terminal 18, 19) ≤±0.1 msWaktu respons sistem (terminal 18, 19, 27, 29, 32, 33) ≤2 msRentang kontrol kecepatan (simpal terbuka) 1:100 kecepatan sinkronRentang kontrol kecepatan (simpal tertutup) 1:1000 dari kecepatan sinkronAkurasi kecepatan (simpal terbuka) 30–4000 RPM: Kesalahan ±8 RPMAkurasi kecepatan (simpal tertutup), tergantung resolusi perangkat umpan balik 0–6000 RPM: Kesalahan ±0.15 RPMAkurasi kontrol torsi (umpan-balik kecepatan) Kesalahan maksimum ±5% dari rating torsi

Semua karakteristik kontrol mengacu pada motor asinkron 4-kutub.

Spesifikasi VLT® AutomationDrive FC 301/302

48 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 51: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

8.7 Sekering dan Pemutus Rangkaian

Gunakan sekering dan/atau pemutus rangkaian yang direkomendasikan sebagai perlindungan jika terjadi kerusakankomponen di dalam konverter frekuensi (masalah pertama).

CATATAN!Penggunaan sekering pada sisi pasokan diwajibkan untuk instalasi yang memenuhi IEC 60364 (CE) and NEC 2009 (UL).

Rekomendasi• Sekering tipe gG

• Pemutus rangkaian tipe Moeller. Untuk tipe pemutus rangkaian lain, pastikan energi yang masuk ke konverterfrekuensi sama dengan atau lebih rendah daripada energi yang dihasilkan oleh tipe Moeller.

Penggunaan sekering dan pemutus rangkaian yang direkomendasikan memastikan potensi kerusakan konverter frekuensidibatasi di dalam unit. Untuk informasi lebih lanjut, lihat Catatan Aplikasi Sekering dan Pemutus Rangkaian.

Sekering pada bab 8.7.1 Kepatuhan terhadap CE ke bab 8.7.2 Memenuhi UL sesuai untuk digunakan pada sirkuit yang dapatmenghasilkan arus 100000 Arms (simetrikal), tergantung rating voltase konverter frekuensi. Dengan sekering yang sesuai,rating arus korslet konverter frekuensi (SCCR) adalah 100000 Arms.

8.7.1 Kepatuhan terhadap CE

200–240 V

Penutup Daya [kW (hp)] Rekomendasiukuran sekering

Rekomendasisekering maksimum

Rekomendasipemutus rangkaian

Moeller

Tingkat anjlokmaksimum [A]

A1 0.25–1.5 (0.34–2.0) gG-10 gG-25 PKZM0-16 16

A2 0.25–1.5 (0.34–2.0) gG-10 gG-25 PKZM0-25 25

2.2 (3.0) gG-16

A3 3.0 (4.0) gG-16 gG-32 PKZM0-25 25

3.7 (5.0) gG-20

A4 0.25–1.5 (0.34–2.0) gG-10 gG-32 PKZM0-25 25

2.2 (3.0) gG-16

A5 0.25–1.5 (0.34–2.0) gG-10 gG-32 PKZM0-25 25

2.2–3.0 (3.0–4.0) gG-16

3.7 (5.0) gG-20

B1 5.5 (7.5) gG-25 gG-80 PKZM4-63 63

7.5 (10.0) gG-32

B2 11.0 (15.0) gG-50 gG-100 NZMB1-A100 100

B3 5.5 (7.5) gG-25 gG-63 PKZM4-50 50

B4 7.5 (10.0) gG-32 gG-125 NZMB1-A100 100

11.0 (15.0) gG-50

15.0 (20.0) gG-63

C1 15.0 (20.0) gG-63 gG-160 NZMB2-A200 160

18.5 (25.0) gG-80

22.0 (30.0) gG-100 aR-160

C2 30.0 (40.0) aR-160 aR-200 NZMB2-A250 250

37.0 (50.0) aR-200 aR-250

C3 18.5 (25.0) gG-80 gG-150 NZMB2-A200 150

22.0 (30.0) aR-125 aR-160

C4 30.0 (40.0) aR-160 aR-200 NZMB2-A250 250

37.0 (50.0) aR-200 aR-250

Tabel 8.13 200–240 V, Ukuran Penutup A, B, and C

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 49

8 8

Page 52: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

380–500 V

Penutup Daya [kW (hp)] Rekomendasiukuran sekering

Rekomendasisekering maksimum

Rekomendasipemutus rangkaian

Moeller

Tingkat anjlokmaksimum [A]

A1 0.37–1.5 (0.5–2.0) gG-10 gG-25 PKZM0-16 16

A2 0.37–3.0 (0.5–4.0) gG-10 gG-25 PKZM0-25 25

4.0 (5.0) gG-16

A3 5.5–7.5 (7.5–10.0) gG-16 gG-32 PKZM0-25 25

A4 0.37–3.0 (0.5–4.0) gG-10 gG-32 PKZM0-25 25

4.0 (5.0) gG-16

A5 0.37–3.0 (0.5–4.0) gG-10 gG-32 PKZM0-25 25

4.0–7.5 (5.0–10.0) gG-16

B1 11–15 (15.0–20.0) gG-40 gG-80 PKZM4-63 63

B2 18.5 (25.0) gG-50 gG-100 NZMB1-A100 100

22.0 (30.0) gG-63

B3 11–15 (15.0–20.0) gG-40 gG-63 PKZM4-50 50

B4 18.5 (25.0) gG-50 gG-125 NZMB1-A100 100

22.0 (30.0) gG-63

30.0 (40.0) gG-80

C1 30.0 (40.0) gG-80 gG-160 NZMB2-A200 160

37.0 (50.0) gG-100

45.0 (60.0) gG-160

C2 55.0 (75.0) aR-200 aR-250 NZMB2-A250 250

75.0 (100.0) aR-250

C3 37.0 (50.0) gG-100 gG-150 NZMB2-A200 150

45.0 (60.0) gG-160 gG-160

C4 55.0 (75.0) aR-200 aR-250 NZMB2-A250 250

75.0 (100.0) aR-250

Tabel 8.14 380–500 V, Ukuran Penutup A, B, dan C

Spesifikasi VLT® AutomationDrive FC 301/302

50 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 53: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

525–600 V

Penutup Daya [kW (hp)] Rekomendasiukuran sekering

Rekomendasisekering maksimum

Rekomendasi pemutusrangkaian

Moeller

Tingkat anjlokmaksimum [A]

A2 0-75-4.0 (1.0–5.0) gG-10 gG-25 PKZM0-25 25

A3 5.5 (7.5) gG-10 gG-32 PKZM0-25 25

7.5 (10.0) gG-16

A5 5.5 (7.5) gG-10 gG-32 PKZM0-25 25

7.5 (10.0) gG-16

B1 11.0 (15.0) gG-25 gG-80 PKZM4-63 63

15.0 (20.0) gG-32

18.5 (25.0) gG-40

B2 22.0 (30.0) gG-50 gG-100 NZMB1-A100 100

30.0 (40.0) gG-63

B3 11.0 (15.0) gG-25 gG-63 PKZM4-50 50

15.0 (20.0) gG-32

B4 18.5 (25.0) gG-40 gG-125 NZMB1-A100 100

22.0 (30.0) gG-50

30.0 (40.0) gG-63

C1 37.0 (50.0) gG-63 gG-160 NZMB2-A200 160

45.0 (60.0) gG-100

55.0 (60.0) aR-160 aR-250

C2 75.0 (100.0) aR-200 aR-250 NZMB2-A250 250

C3 37.0 (50.0) gG-63 gG-150 NZMB2-A200 150

45.0 (60.0) gG-100 gG-150 NZMB2-A200

C4 55.0 (75.0) aR-160 aR-250 NZMB2-A250 250

75.0 (100.0) aR-200

Tabel 8.15 525–600 V, Ukuran Penutup A, B, and C

525–690 V

Penutup Daya [kW (hp)] Rekomendasiukuran sekering

Rekomendasisekering maksimum

Rekomendasipemutus rangkaian

Moeller

Tingkat anjlokmaksimum [A]

A3 1.1 (1.5)1.5 (2.0)2.2 (3.0)3.0 (4.0)4.0 (5.0)5.5 (7.5)

7.5 (10.0)

gG-6gG-6gG-6

gG-10gG-10gG-16gG-16

gG-25gG-25gG-25gG-25gG-25gG-25gG-25

PKZM0-16 16

B2/B4 11.0 (15.0)15.0 (20.0)18.5 (25.0)22.0 (30.0)

gG-25gG-32gG-32gG-40

gG-63

– –

B4/C2 30.0 (40.0) gG-63 gG-80 – –

C2/C3 37.0 (50.0)45.0 (60.0)

gG-63gG-80

gG-100gG-125

– –

C2 55.0 (75.0)75.0 (100.0)

gG-100gG-125

gG-160– –

Tabel 8.16 525–690 V, Ukuran Penutup A, B, and C

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 51

8 8

Page 54: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

8.7.2 Memenuhi UL

200–240 V

Rekomendasi sekering maksimum

Daya [kW(hp)]

Bussmann

Tipe RK11)

BussmannTipe J

BussmannTipe T

BussmannTipe CC

BussmannTipe CC

BussmannTipe CC

0.25–0.37(0.34–0.5)

KTN-R-05 JKS-05 JJN-05 FNQ-R-5 KTK-R-5 LP-CC-5

0.55–1.1(0.75–1.5)

KTN-R-10 JKS-10 JJN-10 FNQ-R-10 KTK-R-10 LP-CC-10

1.5 (2.0) KTN-R-15 JKS-15 JJN-15 FNQ-R-15 KTK-R-15 LP-CC-15

2.2 (3.0) KTN-R-20 JKS-20 JJN-20 FNQ-R-20 KTK-R-20 LP-CC-20

3.0 (4.0) KTN-R-25 JKS-25 JJN-25 FNQ-R-25 KTK-R-25 LP-CC-25

3.7 (5.0) KTN-R-30 JKS-30 JJN-30 FNQ-R-30 KTK-R-30 LP-CC-30

5.5 (7.5) KTN-R-50 KS-50 JJN-50 – – –

7.5 (10.0) KTN-R-60 JKS-60 JJN-60 – – –

11.0 (15.0) KTN-R-80 JKS-80 JJN-80 – – –

15–18.5(20.0–25.0)

KTN-R-125 JKS-125 JJN-125 – – –

22.0 (30.0) KTN-R-150 JKS-150 JJN-150 – – –

30.0 (40.0) KTN-R-200 JKS-200 JJN-200 – – –

37.0 (50.0) KTN-R-250 JKS-250 JJN-250 – – –

Tabel 8.17 200–240 V, Ukuran Penutup A, B, and C

Rekomendasi sekering maksimum

Daya [kW(hp)]

SIBATipe RK1

LittelfuseTipe RK1

Ferraz-ShawmutTipe CC

Ferraz-Shawmut

Tipe RK13)

Bussmann

Tipe JFHR22)

LittelfuseJFHR2

Ferraz-Shawmut

JFHR24)

Ferraz-Shawmut

J

0.25–0.37(0.34–0.5)

5017906-005 KLN-R-05 ATM-R-05 A2K-05-R FWX-5 – – HSJ-6

0.55–1.1(0.75–1.5)

5017906-010 KLN-R-10 ATM-R-10 A2K-10-R FWX-10 – – HSJ-10

1.5 (2.0) 5017906-016 KLN-R-15 ATM-R-15 A2K-15-R FWX-15 – – HSJ-15

2.2 (3.0) 5017906-020 KLN-R-20 ATM-R-20 A2K-20-R FWX-20 – – HSJ-20

3.0 (4.0) 5017906-025 KLN-R-25 ATM-R-25 A2K-25-R FWX-25 – – HSJ-25

3.7 (5.0) 5012406-032 KLN-R-30 ATM-R-30 A2K-30-R FWX-30 – – HSJ-30

5.5 (7.5) 5014006-050 KLN-R-50 – A2K-50-R FWX-50 – – HSJ-50

7.5 (10.0) 5014006-063 KLN-R-60 – A2K-60-R FWX-60 – – HSJ-60

11.0 (15.0) 5014006-080 KLN-R-80 – A2K-80-R FWX-80 – – HSJ-80

15–18.5(20.0–25.0)

2028220-125 KLN-R-125 – A2K-125-R FWX-125 – – HSJ-125

22.0 (30.0) 2028220-150 KLN-R-150 – A2K-150-R FWX-150 L25S-150 A25X-150 HSJ-150

30.0 (40.0) 2028220-200 KLN-R-200 – A2K-200-R FWX-200 L25S-200 A25X-200 HSJ-200

37.0 (50.0) 2028220-250 KLN-R-250 – A2K-250-R FWX-250 L25S-250 A25X-250 HSJ-250

Tabel 8.18 200–240 V, Ukuran Penutup A, B, and C

1) Sekering KTS dari Bussmann bisa menggantikan KTN untukkonverter frekuensi 240 V.2) Sekering FWH dari Bussmann bisa menggantikan FWX untukkonverter frekuensi 240 V.3) Sekering A6KR dari Ferraz Shawmut bisa menggantikan sekeringA2KR untuk konverter frekuensi 240 V.

4) Sekering A50X dari Ferraz Shawmut bisa menggantikan sekeringA25X untuk konverter frekuensi 240 V.

Spesifikasi VLT® AutomationDrive FC 301/302

52 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 55: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

380–500 V

Rekomendasi sekering maksimum

Daya [kW (hp)]BussmannTipe RK1

BussmannTipe J

BussmannTipe T

BussmannTipe CC

BussmannTipe CC

BussmannTipe CC

0.37–1.1 (0.5–1.5) KTS-R-6 JKS-6 JJS-6 FNQ-R-6 KTK-R-6 LP-CC-6

1.5–2.2 (2.0–3.0) KTS-R-10 JKS-10 JJS-10 FNQ-R-10 KTK-R-10 LP-CC-10

3.0 (4.0) KTS-R-15 JKS-15 JJS-15 FNQ-R-15 KTK-R-15 LP-CC-15

4.0 (5.0) KTS-R-20 JKS-20 JJS-20 FNQ-R-20 KTK-R-20 LP-CC-20

5.5 (7.5) KTS-R-25 JKS-25 JJS-25 FNQ-R-25 KTK-R-25 LP-CC-25

7.5 (10.0) KTS-R-30 JKS-30 JJS-30 FNQ-R-30 KTK-R-30 LP-CC-30

11.0 (15.0) KTS-R-40 JKS-40 JJS-40 – – –

15.0 (20.0) KTS-R-50 JKS-50 JJS-50 – – –

18.5 (25.0) KTS-R-60 JKS-60 JJS-60 – – –

22.0 (30.0) KTS-R-80 JKS-80 JJS-80 – – –

30.0 (40.0) KTS-R-100 JKS-100 JJS-100 – – –

37.0 (50.0) KTS-R-125 JKS-125 JJS-125 – – –

45.0 (60.0) KTS-R-150 JKS-150 JJS-150 – – –

55.0 (75.0) KTS-R-200 JKS-200 JJS-200 – – –

75.0 (100.0) KTS-R-250 JKS-250 JJS-250 – – –

Tabel 8.19 380–500 V, Ukuran Penutup A, B, dan C

Rekomendasi sekering maksimum

Daya [kW (hp)]SIBA

Tipe RK1LittelfuseTipe RK1

FerrazShawmutTipe CC

FerrazShawmutTipe RK1

BussmannJFHR2

FerrazShawmut

JFerrazShawmut

J

FerrazShawmut

JFHR21)

LittelfuseJFHR2

0.37–1.1 (0.5–1.5) 5017906-006 KLS-R-6 ATM-R-6 A6K-6-R FWH-6 HSJ-6 – –

1.5–2.2 (2.0–3.0) 5017906-010 KLS-R-10 ATM-R-10 A6K-10-R FWH-10 HSJ-10 – –

3.0 (4.0) 5017906-016 KLS-R-15 ATM-R-15 A6K-15-R FWH-15 HSJ-15 – –

4.0 (5.0) 5017906-020 KLS-R-20 ATM-R-20 A6K-20-R FWH-20 HSJ-20 – –

5.5 (7.5) 5017906-025 KLS-R-25 ATM-R-25 A6K-25-R FWH-25 HSJ-25 – –

7.5 (10.0) 5012406-032 KLS-R-30 ATM-R-30 A6K-30-R FWH-30 HSJ-30 – –

11.0 (15.0) 5014006-040 KLS-R-40 – A6K-40-R FWH-40 HSJ-40 – –

15.0 (20.0) 5014006-050 KLS-R-50 – A6K-50-R FWH-50 HSJ-50 – –

18.5 (25.0) 5014006-063 KLS-R-60 – A6K-60-R FWH-60 HSJ-60 – –

22.0 (30.0) 2028220-100 KLS-R-80 – A6K-80-R FWH-80 HSJ-80 – –

30.0 (40.0) 2028220-125 KLS-R-100 – A6K-100-R FWH-100 HSJ-100 – –

37.0 (50.0) 2028220-125 KLS-R-125 – A6K-125-R FWH-125 HSJ-125 – –

45.0 (60.0) 2028220-160 KLS-R-150 – A6K-150-R FWH-150 HSJ-150 – –

55.0 (75.0) 2028220-200 KLS-R-200 – A6K-200-R FWH-200 HSJ-200 A50-P-225 L50-S-225

75.0 (100.0) 2028220-250 KLS-R-250 – A6K-250-R FWH-250 HSJ-250 A50-P-250 L50-S-250

Tabel 8.20 380–500 V, Ukuran Penutup A, B, dan C

1) Sekering A50QS dari Ferraz Shawmut bisa menggantikan sekeringA50P.

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 53

8 8

Page 56: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

525–600 V

Rekomendasi sekering maksimum

Daya[kW(hp)]

BussmannTipe RK1

BussmannTipe J

BussmannTipe T

BussmannTipe CC

BussmannTipe CC

BussmannTipe CC

SIBATipe RK1

LittelfuseTipe RK1

FerrazShawmutTipe RK1

FerrazShawmut

J

0.75–1.1(1.0–1.5)

KTS-R-5 JKS-5 JJS-6 FNQ-R-5 KTK-R-5 LP-CC-5 5017906-005 KLS-R-005 A6K-5-R HSJ-6

1.5–2.2(2.0–3.0)

KTS-R-10 JKS-10 JJS-10 FNQ-R-10 KTK-R-10 LP-CC-10 5017906-010 KLS-R-010 A6K-10-R HSJ-10

3.0(4.0)

KTS-R15 JKS-15 JJS-15 FNQ-R-15 KTK-R-15 LP-CC-15 5017906-016 KLS-R-015 A6K-15-R HSJ-15

4.0(5.0)

KTS-R20 JKS-20 JJS-20 FNQ-R-20 KTK-R-20 LP-CC-20 5017906-020 KLS-R-020 A6K-20-R HSJ-20

5.5(7.5)

KTS-R-25 JKS-25 JJS-25 FNQ-R-25 KTK-R-25 LP-CC-25 5017906-025 KLS-R-025 A6K-25-R HSJ-25

7.5(10.0)

KTS-R-30 JKS-30 JJS-30 FNQ-R-30 KTK-R-30 LP-CC-30 5017906-030 KLS-R-030 A6K-30-R HSJ-30

11(15.0)

KTS-R-35 JKS-35 JJS-35 – – – 5014006-040 KLS-R-035 A6K-35-R HSJ-35

15.0(20.0)

KTS-R-45 JKS-45 JJS-45 – – – 5014006-050 KLS-R-045 A6K-45-R HSJ-45

18.5(25.0)

KTS-R-50 JKS-50 JJS-50 – – – 5014006-050 KLS-R-050 A6K-50-R HSJ-50

22.0(30.0)

KTS-R-60 JKS-60 JJS-60 – – – 5014006-063 KLS-R-060 A6K-60-R HSJ-60

30.0(40.0)

KTS-R-80 JKS-80 JJS-80 – – – 5014006-080 KLS-R-075 A6K-80-R HSJ-80

37.0(50.0)

KTS-R-100 JKS-100 JJS-100 – – – 5014006-100 KLS-R-100 A6K-100-R HSJ-100

45.0(60.0)

KTS-R-125 JKS-125 JJS-125 – – – 2028220-125 KLS-R-125 A6K-125-R HSJ-125

55.0(75.0)

KTS-R-150 JKS-150 JJS-150 – – – 2028220-150 KLS-R-150 A6K-150-R HSJ-150

75.0(100.0)

KTS-R-175 JKS-175 JJS-175 – – – 2028220-200 KLS-R-175 A6K-175-R HSJ-175

Tabel 8.21 525–600 V, Ukuran Penutup A, B, and C

Spesifikasi VLT® AutomationDrive FC 301/302

54 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 57: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

525–690 V

Rekomendasi sekering maksimum

Daya [kW(hp)]

BussmannTipe RK1

BussmannTipe J

BussmannTipe T

BussmannTipe CC

BussmannTipe CC

BussmannTipe CC

1.1 (1.5) KTS-R-5 JKS-5 JJS-6 FNQ-R-5 KTK-R-5 LP-CC-5

1.5–2.2(2.0–3.0)

KTS-R-10 JKS-10 JJS-10 FNQ-R-10 KTK-R-10 LP-CC-10

3.0 (4.0) KTS-R15 JKS-15 JJS-15 FNQ-R-15 KTK-R-15 LP-CC-15

4.0 (5.0) KTS-R20 JKS-20 JJS-20 FNQ-R-20 KTK-R-20 LP-CC-20

5.5 (7.5) KTS-R-25 JKS-25 JJS-25 FNQ-R-25 KTK-R-25 LP-CC-25

7.5 (10.0) KTS-R-30 JKS-30 JJS-30 FNQ-R-30 KTK-R-30 LP-CC-30

11.0 (15.0) KTS-R-35 JKS-35 JJS-35 – – –

15.0 (20.0) KTS-R-45 JKS-45 JJS-45 – – –

18.5 (25.0) KTS-R-50 JKS-50 JJS-50 – – –

22.0 (30.0) KTS-R-60 JKS-60 JJS-60 – – –

30.0 (40.0) KTS-R-80 JKS-80 JJS-80 – – –

37.0 (50.0) KTS-R-100 JKS-100 JJS-100 – – –

45.0 (60.0) KTS-R-125 JKS-125 JJS-125 – – –

55.0 (75.0) KTS-R-150 JKS-150 JJS-150 – – –

75.0(100.0)

KTS-R-175 JKS-175 JJS-175 – – –

Tabel 8.22 525–690 V, Ukuran Penutup A, B, and C

Rekomendasi sekering maksimum

Daya [kW(hp)]

Prasekering

maksimum

BussmannE52273

RK1/JDDZ

BussmannE4273J/JDDZ

BussmannE4273

T/JDDZ

SIBAE180276

RK1/JDDZ

LittelfuseE81895

RK1/JDDZ

FerrazShawmutE163267/

E2137RK1/JDDZ

FerrazShawmut

E2137J/HSJ

11.0 (15.0) 30 A KTS-R-30 JKS-30 JKJS-30 5017906-030 KLS-R-030 A6K-30-R HST-30

15–18.5(20.0–25.0)

45 A KTS-R-45 JKS-45 JJS-45 5014006-050 KLS-R-045 A6K-45-R HST-45

22.0 (30.0) 60 A KTS-R-60 JKS-60 JJS-60 5014006-063 KLS-R-060 A6K-60-R HST-60

30.0 (40.0) 80 A KTS-R-80 JKS-80 JJS-80 5014006-080 KLS-R-075 A6K-80-R HST-80

37.0 (50.0) 90 A KTS-R-90 JKS-90 JJS-90 5014006-100 KLS-R-090 A6K-90-R HST-90

45.0 (60.0) 100 A KTS-R-100 JKS-100 JJS-100 5014006-100 KLS-R-100 A6K-100-R HST-100

55.0 (75.0) 125 A KTS-R-125 JKS-125 JJS-125 2028220-125 KLS-150 A6K-125-R HST-125

75.0 (100.0) 150 A KTS-R-150 JKS-150 JJS-150 2028220-150 KLS-175 A6K-150-R HST-150

Tabel 8.23 525–690 V, Ukuran Penutup B, dan C

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 55

8 8

Page 58: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

8.8 Torsi Pengencangan Sambungan

UkuranPenutup

200–240 V[kW (hp)]

380–500 V[kW (hp)]

525–690 V[kW (hp)]

Tujuan Torsi pengencangan[Nm] ([in-lb])

A2 0.25–2.2(0.34–3.0)

0.37–4(0.5–5.0) – Kabel sumber listrik, resistor rem, pembagi beban, dan

motor0.5–0.6 (4.4–5.3)

A3 3–3.7(4.0–5.0)

5.5–7.5(7.5–10.0)

1.1–7.5(1.5–10.0)

A4 0.25–2.2(0.34–3.0)

0.37–4(0.5–5.0) –

A5 3–3.7(4.0–5.0)

5.5–7.5(7.5–10.0) –

B1 5.5–7.5(7.5–10.0)

11–15(15–20) –

Kabel sumber listrik, resistor rem, pembagi beban, danmotor

1.8 (15.9)

Relai 0.5–0.6 (4.4–5.3)Pembumi 2–3 (17.7–26.6)

B2 11 (15) 18.5–22(25–30)

11–22(15–30)

Kabel sumber listrik, resistor rem, pembagi beban 4.5 (39.8)Kabel motor. 4.5 (39.8)Relai 0.5–0.6 (4.4–5.3)Pembumi 2–3 (17.7–26.6)

B3 5.5–7.5(7.5–10.0)

11–15(15–20) –

Kabel sumber listrik, resistor rem, pembagi beban, danmotor

1.8 (15.9)

Relai 0.5–0.6 (4.4–5.3)Pembumi 2–3 (17.7–26.6)

B4 11–15(15–20)

18.5–30(25–40)

11–30(15–40)

Kabel sumber listrik, resistor rem, pembagi beban, danmotor

4.5 (39.8)

Relai 0.5–0.6 (4.4–5.3)Pembumi 2–3 (17.7–26.6)

C1 15–22(20–30)

30–45(40–60) –

Kabel sumber listrik, resistor rem, pembagi beban 10 (89)Kabel motor. 10 (89)Relai 0.5–0.6 (4.4–5.3)Pembumi 2–3 (17.7–26.6)

C2 30–37(40–50)

55–75(75–100)

30–75(40–100)

Kabel sumber listrik, motor 14 (124) (hingga 95 mm2

(3 AWG))24 (212) (di atas 95 mm2

(3 AWG))Pembagi beban, kabel rem 14 (124)Relai 0.5–0.6 (4.4–5.3)Pembumi 2–3 (17.7–26.6)

C3 18.5–22(25–30)

30–37(40–50)

37–45(50–60)

Kabel sumber listrik, resistor rem, pembagi beban, danmotor

10 (89)

Relai 0.5–0.6 (4.4–5.3)Pembumi 2–3 (17.7–26.6)

C4 37–45(50–60)

55–75(75–100)

11–22(15–30)

Kabel sumber listrik, motor 14 (124) (hingga 95 mm2

(3 AWG))24 (212) (di atas 95 mm2

(3 AWG))Pembagi beban, kabel rem 14 (124)Relai 0.5–0.6 (4.4–5.3)Pembumi 2–3 (17.7–26.6)

Tabel 8.24 Torsi Pengencangan untuk Kabel

Spesifikasi VLT® AutomationDrive FC 301/302

56 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 59: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

8.9 Rating Daya, Berat, dan Dimensi

Uku

ran

pen

utup

A1

A2

A3

A4

A5

Day

a te

ruku

r[k

W (h

p)]

200–

240

V0.

25–1

.5(0

.34–

2)0.

25–2

.2(0

.34–

3)3–

3.7

(4–5

)0.

25–2

.2(0

.34–

3)0.

25–3

.7(0

.34–

5)

38

0–48

0/50

0 V

0.37

–1.5

(0.5

–2)

0.37

–4(0

.5–5

)5.

5–7.

5(7

.5–1

0)0.

37–4

(0.5

–5)

0.37

–7.5

(0.5

–10)

52

5–60

0 V

––

0.75

–7.5

(1–1

0)–

0.75

–7.5

(1–1

0)

52

5–69

0 V

––

1.1–

7.5

(1.5

–10)

––

IP NEM

A–

20 Sasi

s20 Sa

sis

21Ti

pe 1

20 Sasi

s21

Tipe

155

/66

Jeni

s 12

/4X

55/6

6Je

nis

12/4

X

Ting

gi [m

m (i

n)]

Ting

gi p

emas

anga

n p

elat

A1)

200

(7.9

)26

8(1

0.6)

375

(14.

8)26

8(1

0.6)

375

(14.

8)39

0(1

5.4)

420

(16.

5)

Ketin

ggia

n d

enga

n p

elat

term

inas

i ard

e un

tuk

kabe

lfie

ldbu

sA

316

(12.

4)37

4(1

4.7)

–37

4(1

4.7)

––

Jara

k an

tara

luba

ng p

emas

anga

na

190

(7.5

)25

7(1

0.1)

350

(13.

8)25

7(1

0.1)

350

(13.

8)40

1(1

5.8)

402

(15.

8)

Leba

r [m

m (i

n)]

Leba

r pe

lat

pem

asan

gan

pel

atB

75 (3)

90 (3.5

)90 (3.5

)13

0(5

.1)

130

(5.1

)20

0(7

.9)

242

(9.5

)

Leba

r pe

lat

pem

asan

gan

pel

at d

enga

n 1

ops

i CB

–13

0(5

.1)

130

(5.1

)17

0(6

.7)

170

(6.7

)–

242

(9.5

)

Leba

r pe

lat

pem

asan

gan

pel

at d

enga

n 2

ops

i CB

–15

0(5

.9)

150

(5.9

)19

0(7

.5)

190

(7.5

)–

242

(9.5

)

Jara

k an

tara

luba

ng p

emas

anga

nb

60 (2

.4)

70 (2

.8)

70 (2

.8)

110

(4.3

)11

0 (4

.3)

171

(6.7

)21

5 (8

.5)

Keda

lam

an [m

m (i

n)]

Keda

lam

an t

anpa

ops

i A/B

C20

7 (8

.1)

205

(8.1

)20

7 (8

.1)

205

(8.1

)20

7 (8

.1)

175

(6.9

)20

0 (7

.9)

Den

gan

ops

i A/B

C22

2 (8

.7)

220

(8.7

)22

2 (8

.7)

220

(8.7

)22

2 (8

.7)

175

(6.9

)20

0 (7

.9)

Luba

ng s

ekru

p [m

m (i

n)]

c6.

0 (0

.24)

8.0

(0.3

1)8.

0 (0

.31)

8.0

(0.3

1)8.

0 (0

.31)

8.25

(0.3

2)8.

25 (0

.32)

dø8

(ø0.

31)

ø11

(ø0.

43)

ø11

(ø0.

43)

ø11

(ø0.

43)

ø11

(ø0.

43)

ø12

(ø0.

47)

ø12

(ø0.

47)

eø5

(ø0.

2)ø5

.5 (ø

0.22

)ø5

.5 (ø

0.22

)ø5

.5 (ø

0.22

)ø5

.5 (ø

0.22

)ø6

.5 (ø

0.26

)ø6

.5 (ø

0.26

)

f5

(0.2

)9

(0.3

5)9

(0.3

5)6.

5 (0

.26)

6.5

(0.2

6)6

(0.2

4)9

(0.3

5)

Bobo

t m

aksi

mum

[kg

(lb)

]2.

7 (6

)4.

9 (1

0.8)

5.3

(11.

7)6.

6 (1

4.6)

7 (1

5.4)

9.7

(21.

4)13

.5/1

4.2

(30/

31)

Tors

i pen

genc

anga

n p

enut

up d

epan

[Nm

(in-

lb)]

Penu

tup

pla

stik

(IP

rend

ah)

Klik

Klik

Klik

––

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 57

8 8

Page 60: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Uku

ran

pen

utup

A1

A2

A3

A4

A5

Day

a te

ruku

r[k

W (h

p)]

200–

240

V0.

25–1

.5(0

.34–

2)0.

25–2

.2(0

.34–

3)3–

3.7

(4–5

)0.

25–2

.2(0

.34–

3)0.

25–3

.7(0

.34–

5)

38

0–48

0/50

0 V

0.37

–1.5

(0.5

–2)

0.37

–4(0

.5–5

)5.

5–7.

5(7

.5–1

0)0.

37–4

(0.5

–5)

0.37

–7.5

(0.5

–10)

52

5–60

0 V

––

0.75

–7.5

(1–1

0)–

0.75

–7.5

(1–1

0)

52

5–69

0 V

––

1.1–

7.5

(1.5

–10)

––

Penu

tup

Met

al (I

P55/

66)

––

–1.

5 (1

3.3)

1.5

(13.

3)

1) L

ihat

Ilus

tras

i 8.2

dan

Ilus

tras

i 8.3

unt

uk lu

bang

pem

asan

gan

di a

tas

dan

baw

ah

Tabe

l 8.2

5 Ra

ting

Day

a, B

erat

dan

Dim

ensi

, Uku

ran

Pen

utup

A1–

A5

Spesifikasi VLT® AutomationDrive FC 301/302

58 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 61: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Uku

ran

pen

utup

B1B2

B3B4

Day

a te

ruku

r[k

W (h

p)]

200–

240

V5.

5–7.

5(7

.5–1

0)15

5.5–

7.5

(7.5

–10)

11–1

5(1

5–20

)

38

0–48

0/50

0 V

11–1

5(1

5–20

)18

.5–2

2(2

5–30

)11

–15

(15–

20)

18.5

–30

(25–

40)

52

5–60

0 V

11–1

5(1

5–20

)18

.5–2

2(2

5–30

)11

–15

(15–

20)

18.5

–30

(25–

40)

52

5–69

0 V

–11

–22

(15–

30)

–11

–30

(15–

40)

IP NEM

A–

21/5

5/66

Jeni

s 1/

12/4

X21

/55/

66Je

nis

1/12

/4X

20 Sasi

s20 Sa

sis

Ting

gi [m

m (i

n)]

Ting

gi p

emas

anga

n p

elat

A1)

480

(18.

9)65

0(2

5.6)

399

(15.

7)52

0(2

0.5)

Ketin

ggia

n d

enga

n p

elat

term

inas

i ard

e un

tuk

kabe

l fieldb

usA

––

420

(16.

5)59

5(2

3.4)

Jara

k an

tara

luba

ng p

emas

anga

na

454

(17.

9)62

4(2

4.6)

380

(15)

495

(19.

5)

Leba

r [m

m (i

n)]

Leba

r pe

lat

pem

asan

gan

pel

atB

242

(9.5

)24

2(9

.5)

165

(6.5

)23

0(9

.1)

Leba

r pe

lat

pem

asan

gan

pel

at d

enga

n 1

ops

i CB

242

(9.5

)24

2(9

.5)

205

(8.1

)23

0(9

.1)

Leba

r pe

lat

pem

asan

gan

pel

at d

enga

n 2

ops

i CB

242

(9.5

)24

2 (9

.5)

225

(8.9

)23

0 (9

.1)

Jara

k an

tara

luba

ng p

emas

anga

nb

210

(8.3

)21

0 (8

.3)

140

(5.5

)20

0 (7

.9)

Keda

lam

an [m

m (i

n)]

Keda

lam

an t

anpa

ops

i A/B

C26

0 (1

0.2)

260

(10.

2)24

9 (9

.8)

242

(9.5

)

Den

gan

ops

i A/B

C26

0 (1

0.2)

260

(10.

2)26

2 (1

0.3)

242

(9.5

)

Luba

ng s

ekru

p [m

m (i

n)]

c12

(0.4

7)12

(0.4

7)8

(0.3

1)–

dø1

9 (ø

0.75

)ø1

9 (ø

0.75

)12

(0.4

7)–

eø9

(ø0.

35)

ø9 (ø

0.35

)6.

8 (0

.27)

8.5

(0.3

3)

f9

(0.3

5)9

(0.3

5)7.

9 (0

.31)

15 (0

.59)

Bobo

t m

aksi

mum

[kg

(lb)

]23

(51)

27 (6

0)12

(26.

5)23

.5 (5

2)

Tors

i pen

genc

anga

n p

enut

up d

epan

[Nm

(in-

lb)]

Penu

tup

pla

stik

(IP

rend

ah)

Klik

Klik

Klik

Klik

Penu

tup

Met

al (I

P55/

66)

2.2

(19.

5)2.

2 (1

9.5)

––

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 59

8 8

Page 62: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Uku

ran

pen

utup

B1B2

B3B4

Day

a te

ruku

r[k

W (h

p)]

200–

240

V5.

5–7.

5(7

.5–1

0)15

5.5–

7.5

(7.5

–10)

11–1

5(1

5–20

)

38

0–48

0/50

0 V

11–1

5(1

5–20

)18

.5–2

2(2

5–30

)11

–15

(15–

20)

18.5

–30

(25–

40)

52

5–60

0 V

11–1

5(1

5–20

)18

.5–2

2(2

5–30

)11

–15

(15–

20)

18.5

–30

(25–

40)

52

5–69

0 V

–11

–22

(15–

30)

–11

–30

(15–

40)

1) L

ihat

Ilus

tras

i 8.2

dan

Ilus

tras

i 8.3

unt

uk lu

bang

pem

asan

gan

di a

tas

dan

baw

ah

Tabe

l 8.2

6 Ra

ting

Day

a, B

erat

, dan

Dim

ensi

, Uku

ran

Pen

utup

B1–

B4

Spesifikasi VLT® AutomationDrive FC 301/302

60 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 63: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Ukuran penutup C1 C2 C3 C4 D3h

Daya terukur[kW (hp)]

200–240 V 15–22(20–30)

30–37(40–50)

18.5–22(25–30)

30–37(40–50)

380–480/500 V 30–45(40–60)

55–75(75–100)

37–45(50–60)

55–75(75–100)

525–600 V 30–45(40–60)

55–90(75–125)

37–45(50–60)

55–90(75–125)

525–690 V–

30–75(40–100)

37–45(50–60)

37–45(50–60)

55–75(75–100)

IPNEMA

–21/55/66

Jenis 1/12/4X21/55/66

Jenis 1/12/4X20

Sasis20

Sasis20

Sasis

Tinggi [mm (in)]

Tinggi pemasangan pelat A1)680

(26.8)770

(30.3)550

(21.7)660(26)

909(35.8)

Ketinggian dengan pelat terminasi ardeuntuk kabel fieldbus

A – –630

(24.8)800

(31.5)–

Jarak antara lubang pemasangan a648

(25.5)739

(29.1)521

(20.5)631

(24.8)–

Lebar [mm (in)]

Lebar pelat pemasangan pelat B308

(12.1)370

(14.6)308

(12.1)370

(14.6)250(9.8)

Lebar pelat pemasangan pelat dengan 1opsi C

B308

(12.1)370

(14.6)308

(12.1)370

(14.6)–

Lebar pelat pemasangan pelat dengan 2opsi C

B 308 (12.1) 370 (14.6) 308 (12.1) 370 (14.6) –

Jarak antara lubang pemasangan b 272 (10.7) 334 (13.1) 270 (10.6) 330 (13) –

Kedalaman [mm (in)]

Kedalaman tanpa opsi A/B C 310 (12.2) 335 (13.2) 333 (13.1) 333 (13.1) 375 (14.8)

Dengan opsi A/B C 310 (12.2) 335 (13.2) 333 (13.1) 333 (13.1) 375 (14.8)

Lubang sekrup [mm (in)]

c 12.5 (0.49) 12.5 (0.49) – – –

d ø19 (ø0.75) ø19 (ø0.75) – – –

e ø9 (ø0.35) ø9 (ø0.35) 8.5 (0.33) 8.5 (0.33) –

f 9.8 (0.39) 9.8 (0.39) 17 (0.67) 17 (0.67) –

Bobot maksimum [kg (lb)] 45 (99) 65 (143) 35 (77) 50 (110) 62 (137)

Torsi pengencangan penutup depan [Nm (in-lb)]

Penutup plastik (IP rendah) Klik Klik 2 (17.7) 2 (17.7) –

Penutup Metal (IP55/66) 2.2 (19.5) 2.2 (19.5) 2 (17.7) 2 (17.7) –

1) Lihat Ilustrasi 8.2 dan Ilustrasi 8.3 untuk lubang pemasangan di atas dan bawah

Tabel 8.27 Rating Daya, Berat, dan Dimensi, Ukuran Penutup C1–C4 dan D3h

Spesifikasi Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 61

8 8

Page 64: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

C

a

b13

0BA64

8.12

f

e

B

A

a

d

e

b

c

Ilustrasi 8.2 Lubang Pemasangan di Atas dan Bawah(Lihatbab 8.9 Rating Daya, Berat, dan Dimensi)

a

e

f

130B

A71

5.12

Ilustrasi 8.3 Lubang Pemasangan di Atas dan Bawah (B4, C3,dan C4)

Spesifikasi VLT® AutomationDrive FC 301/302

62 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

88

Page 65: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

9 Apendiks

9.1 Simbol, Singkatan, dan Konvensi

°C Derajat Celsius

°F Derajat Fahrenheit

AC Arus bolak-balik

AEO Optimisasi energi otomatis

AWG Ukuran kawat Amerika

AMA Adaptasi motor otomatis

DC Arus searah

EMC Kompatibilitas elektromagnetik

ETR Relai termal elektronik

fM,N Frekuensi motor nominal

FC Konverter frekuensi

IINV Rating arus output inverter

ILIM Batas arus

IM,N Arus motor nominal

IVLT,MAX Arus output maksimum

IVLT,N Rating arus output yang dicatu oleh konverter frekuensi

IP Proteksi ingress (rembesan)

LCP Panel kontrol lokal

MCT Alat kontrol gerak

ns Kecepatan motor sinkron

PM,N Daya motor nominal

PELV Voltase ekstra rendah pelindung

PCB Papan sirkuit cetak

PM Motor Motor magnet permanen

PWM Modulasi lebar denyut

RPM Revolusi per menit

Regen Terminal regeneratif

TLIM Batas torsi

UM,N Voltase motor nominal

Tabel 9.1 Simbol dan Singkatan

KonvensiDaftar bernomor menunjukkan prosedur. Daftar poin berisi informasi lain.

Teks miring berarti:• Rujukan silang.

• Link.

• Nama parameter.

• Nama grup parameter.

• Opsi parameter.

• Catatan kaki.

Semua dimensi dalam gambar adalah dalam mm [mm] (in).

9.2 Struktur Menu Parameter

Apendiks Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 63

9 9

Page 66: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

9.2.

1Pe

rang

kat

luna

k8.

12

0-**

Ope

rasi

/ T

ampi

lan

0-0*

Peng

atur

an D

asar

0-01

Baha

sa0-

02Sa

tuan

Kec

epat

an M

otor

0-03

Peng

atur

an R

egio

nal

0-04

Stat

us O

pera

si s

aat

Pend

ayaa

n(M

anua

l)0-

09M

onito

r Pe

rfor

ma

0-1*

Ope

rasi

Pen

gatu

ran

0-10

Peng

atur

an A

ktif

0-11

Edit

Pen

gatu

ran

0-12

Peng

atur

an in

i Ter

kait

ke

0-13

Baca

an: P

enga

tura

n T

erhu

bung

0-14

Baca

an: P

enga

tura

n E

dit

/ Sa

lura

n0-

15Ba

caan

: pen

gatu

ran

akt

ual

0-2*

Tam

pila

n L

CP0-

20Ba

ris T

ampi

lan

1.1

Kec

il0-

21Ba

ris T

ampi

lan

1.2

Kec

il0-

22Ba

ris T

ampi

lan

1.3

Kec

il0-

23Ba

ris T

ampi

lan

2 B

esar

0-24

Baris

Tam

pila

n 3

Bes

ar0-

25M

enu

Prib

adik

u0-

3*Ba

caan

Kus

tom

LCP

0-30

Uni

t un

tuk

Baca

an y

ang

Dite

ntuk

anPe

nggu

na0-

31N

ilai M

in. B

acaa

n y

ang

Dite

ntuk

anPe

nggu

na0-

32N

ilai M

aks.

Bac

aan

yan

g D

itent

ukan

Peng

guna

0-33

Sum

ber

untu

k pe

mba

caan

yan

gdi

tent

ukan

Pen

ggun

a0-

37Te

ks T

ampi

lan

10-

38Te

ks T

ampi

lan

20-

39Te

ks T

ampi

lan

30-

4*Pa

pan

Tik

LCP

0-40

Tom

bol [

Han

d o

n] p

ada

LCP

0-41

Tom

bol [Off]

(Mat

i) pa

da L

CP0-

42To

mbo

l [Au

to o

n] p

ada

LCP

0-43

Tom

bol [

Rese

t] p

ada

LCP

0-44

Tom

bol [Off/Re

set]

pad

a LC

P0-

45To

mbo

l [D

rive

Bypa

ss]

pada

LCP

0-5*

Salin

/Sim

pan

0-50

Salin

an L

CP0-

51Sa

linan

Pen

gatu

ran

0-6*

Sand

i0-

60Kt

. san

di M

enu

Uta

ma

0-61

Aks

es k

e M

enu

Uta

ma

tanp

a kt

. San

di0-

65Kt

. San

di M

enu

Cep

at0-

66A

kses

ke

Men

u C

epat

tan

pa k

t. S

andi

0-67

Aks

es K

ata

Sand

i Bus

0-68

Kese

lam

atan

Par

amet

er S

andi

0-69

Perli

ndun

gan

Kod

e Sa

ndi d

ari

Keam

anan

Par

amet

er0-

7*Pe

ngat

uran

Jam

0-70

Tang

gal d

an J

am

0-71

Form

at T

angg

al0-

72Fo

rmat

Wak

tu0-

73U

bah

Zon

a W

aktu

0-74

DST

/Mus

im p

anas

0-76

DST

/Aw

al M

usim

Pan

as0-

77D

ST/A

khir

Mus

im P

anas

0-79

Jam

Ber

mas

alah

0-81

Har

i Ker

ja0-

82H

ari K

erja

Tam

baha

n0-

83Bu

kan

Har

i Ker

ja T

amba

han

0-84

Wak

tu u

ntuk

Fie

ldbu

s0-

85Ja

m M

usim

Pan

as D

imul

ai u

ntuk

Fiel

dbus

0-86

Akh

ir J

am M

usim

Pan

as u

ntuk

Fie

ldbu

s0-

89Ba

caan

Tan

ggal

dan

Jam

1-**

Beba

n d

an M

otor

1-0*

Peng

atur

an U

mum

1-00

Mod

e Ko

nfigu

rasi

1-01

Prin

sip

Kon

trol

Mot

or1-

02Su

mbe

r Fl

uks

deng

an U

mpa

n B

alik

Mot

or1-

03Ka

rakt

eris

tik T

orsi

1-04

Mod

e Ke

lebi

han

Beb

an1-

05Ko

nfigu

rasi

Mod

e Lo

kal

1-06

Sear

ah J

arum

Jam

1-07

Peny

esua

ian

Offset

Sud

ut M

otor

1-1*

Peng

atur

an K

husu

s1-

10Ko

nstr

uksi

Mot

or1-

11M

odel

Mot

or1-

14G

ain

Per

edam

1-15

Kons

tant

a W

aktu

Filt

er K

ecep

atan

Rend

ah1-

16Ko

nsta

nta

Wak

tu F

ilter

Kec

epat

anTi

nggi

1-17

Kons

tant

a w

aktu

filte

r vo

ltase

1-18

Min

. aru

s pa

da T

idak

Ada

Beb

an1-

2*D

ata

Mot

or1-

20D

aya

Mot

or [k

W]

1-21

Day

a M

otor

[HP]

1-22

Volta

se M

otor

1-23

Frek

uens

i Mot

or1-

24A

rus

Mot

or1-

25Ke

cepa

tan

Nom

inal

Mot

or1-

26Ko

n. M

otor

Rat

ing

Tor

si1-

29Ad

apta

si M

otor

Oto

mat

is (A

MA

)1-

3*P'

atur

an D

ata

Mot

or1-

30Re

sist

ansi

Sta

tor

(Rs)

1-31

Resi

stan

si R

otor

(Rr)

1-33

Reak

tans

i Keb

ocor

an S

tato

r (X

1)1-

34Re

akta

nsi K

eboc

oran

Rot

or (X

2)1-

35Re

akta

nsi U

tam

a (X

h)1-

36Ta

hana

n K

ehila

ngan

Bes

i (Rf

e)1-

37In

dukt

ansi

sum

bu-d

(Ld)

1-38

Indu

ktan

si s

umbu

q (L

q)1-

39Ku

tub

Mot

or1-

40Ba

ck E

MF

pada

100

0 RP

M1-

41Offset

Sud

ut M

otor

1-44

Indu

ktan

si s

umbu

-d S

at. (

LdSa

t)1-

45In

dukt

ansi

sum

bu q

Sat

. (Lq

Sat)

1-46

Gai

n D

etek

si P

osis

i1-

47Ka

libra

si T

orsi

1-48

Indu

ktan

si S

at. P

oin

1-49

Titik

Sat

uras

i Ind

ukta

nsi S

umbu

q1-

5*Pe

ngat

uran

Tak

Ter

gant

ung

Beb

an1-

50M

agne

tisas

i Mot

or p

ada

Kece

pata

n N

ol1-

51M

agne

tisas

i Nor

mal

Kec

ep. M

in. [

RPM

]1-

52M

agne

tisas

i Nor

mal

Kec

epat

an M

in[H

z]1-

53Fr

ekue

nsi G

eser

Mod

el1-

54Ku

rang

an t

eg d

i p'le

mah

med

an1-

55Ka

rakt

eris

tik U

/f -

U1-

56Ka

rakt

eris

tik U

/f -

F1-

58A

rus

Puls

a U

ji St

art

Mel

ayan

g1-

59Fr

ekue

nsi P

ulsa

Uji

Star

t M

elay

ang

1-6*

T'ga

ntun

g B

eban

Pen

gatu

ran

1-60

Kom

pens

asi B

eban

Kec

epat

an R

enda

h1-

61Ko

mpe

nsas

i Beb

an K

ecep

atan

Tin

ggi

1-62

Kom

pens

asi S

lip1-

63Ko

nsta

nta

Wak

tu K

ompe

nsas

i Slip

1-64

Pere

dam

an R

eson

ansi

1-65

Kons

tant

a W

aktu

Per

edam

an R

eson

ansi

1-66

Aru

s M

in. p

ada

Kece

pata

n R

enda

h1-

67Je

nis

Beba

n1-

68In

ersi

a M

otor

1-69

Iner

sia

Sist

em1-

7*Pe

nyes

uaia

n S

tart

1-70

Mod

e St

art

1-71

Penu

ndaa

n S

tart

1-72

Fung

si S

tart

1-73

Star

t M

elay

ang

1-74

Kece

pata

n S

tart

[RPM

]1-

75Ke

cepa

tan

Sta

rt [H

z]1-

76A

rus

Star

t1-

8*Pe

nyes

uaia

n B

erhe

nti

1-80

Fung

si s

aat

Berh

enti

1-81

Kece

p. M

in. u

tk F

ungs

i saa

t Be

rhen

ti[R

PM]

1-82

Kece

pata

n M

in u

ntuk

Fun

gsi S

aat

Berh

enti

[Hz]

1-83

Fung

si B

erhe

nti T

epat

1-84

Nila

i Pen

ghitu

ng B

erhe

nti T

epat

1-85

Pnun

da K

ompe

n k

ecep

Sto

p P

resi

si1-

9*Su

hu M

otor

1-90

Prot

eksi

Ter

mal

Mot

or1-

91Ki

pas

Ekst

erna

l Mot

or1-

93Su

mbe

r Th

erm

isto

r1-

94Pe

ngur

anga

n k

ecep

atan

bts

. aru

s. E

TRAT

EX1-

95Ti

pe S

enso

r Te

rmis

tor

1-96

Sum

ber

Day

a Se

nsor

Ter

mis

tor

1-97

Ting

kat

Am

bang

Ter

mis

tor

1-98

Frek

. poi

n in

terp

ol. E

TR A

TEX

1-99

Aru

s po

in in

terp

ol E

TR A

TEX

2-**

Rem

2-0*

Rem

-DC

2-00

Aru

s Pe

naha

n D

C2-

01A

rus

Rem

DC

2-02

Wak

tu P

enge

rem

an D

C

2-03

Kece

pata

n P

enye

laan

Rem

DC

[RPM

]2-

04Ke

cepa

tan

Pen

yela

an R

em D

C [H

z]2-

05Re

fere

nsi M

aksi

mum

2-06

Aru

s Pa

rkir

2-07

Wak

tu P

arki

r2-

1*Fu

ngsi

Ene

rgi R

em2-

10Fu

ngsi

Rem

2-11

Taha

nan

Rem

(ohm

)2-

12Ba

tas

Day

a Re

m (k

W)

2-13

Pem

anta

uan

Day

a Re

m2-

15Pe

riksa

Rem

2-16

Aru

s M

aks

Rem

AC

2-17

Kont

rol K

eleb

ihan

Vol

tase

2-18

Perik

sa K

ondi

si R

em2-

19G

ain

Kel

ebih

an V

olta

se2-

2*Re

m M

ekan

is2-

20A

rus

Pele

pas

Rem

2-21

Kcpt

n. u

tk A

ktifk

an R

em [R

PM]

2-22

Kece

pata

n u

ntuk

Men

gakt

ifkan

Rem

[Hz]

2-23

Penu

ndaa

n P

enga

ktifa

n R

em2-

24St

op d

elay

2-25

Wak

tu P

elep

asan

Rem

2-26

Ref.

Tors

i2-

27To

rsi W

aktu

Tan

jaka

n2-

28Fa

ktor

Boo

st P

erol

ehan

2-29

Tors

i Wak

tu R

amp

Baw

ah2-

3*P'

atur

an R

em M

ekan

is2-

30Po

sisi

Pen

guat

an P

ropo

rsio

nal S

tart

P2-

31Ke

cepa

tan

Sta

rt P

ID P

erol

ehan

Pro

por-

sion

al2-

32Ke

cepa

tan

Sta

rt P

ID w

aktu

Inte

gral

2-33

Kece

pata

n S

tart

PID

wak

tu F

ilter

lulu

s-tin

gkat

baw

ah3-

**Re

fere

nsi /

Aks

eler

asi-D

esel

eras

i3-

0*Ba

tas

Refe

rens

i3-

00Ki

sara

n R

efer

ensi

3-01

Uni

t Re

fere

nsi/U

mpa

n B

alik

3-02

Refe

rens

i Min

imum

3-03

Refe

rens

i Mak

sim

um3-

04Fu

ngsi

Ref

eren

si3-

1*Re

fere

nsi

3-10

Refe

rens

i Pre

set

3-11

Kece

pata

n J

og [H

z]3-

12N

ilai P

enge

jara

n/Pe

rlam

bata

n3-

13Si

tus

Refe

rens

i3-

14Re

fere

nsi R

elat

if Pr

eset

3-15

Sum

ber

Refe

rens

i 13-

16Su

mbe

r Re

fere

nsi 2

3-17

Sum

ber

Refe

rens

i 33-

18Su

mbe

r Re

fere

nsi P

ensk

alaa

n R

elat

if3-

19Ke

cepa

tan

Jog

[RPM

]3-

4*Ra

mp

13-

40Je

nis

Ram

p 1

3-41

Wak

tu R

amp

Up

Ram

p 1

3-42

Wak

tu R

amp

Dow

n R

amp

13-

45Tn

j.1 R

asio

tnj

-S p

d N

aik

Perc

. Sta

rt3-

46Tn

j.1 R

asio

tnj

-S p

d N

aik

Perc

. Akh

ir3-

47Tn

j.1 R

asio

tnj

-S p

d T

urun

Per

c. S

tart

3-48

Tnj.1

Ras

io t

nj-S

pd

Tur

un P

erc.

Akh

ir3-

5*Ra

mp

23-

50Je

nis

Ram

p 2

3-51

Aks

eler

asi/D

esel

eras

i Wak

tu A

ksel

eras

i2

3-52

Wak

tu R

amp

Dow

n R

amp

23-

55Tn

j.2 R

asio

tnj

-S p

d A

wal

Sta

rt3-

56Tn

j.2 R

asio

tnj

-S p

d A

wal

Akh

ir3-

57Tn

j.2 R

asio

tnj

-S p

d T

urun

Per

c. S

tart

3-58

Tnj.2

Ras

io t

nj-S

pd

Tur

un P

erc.

Akh

ir3-

6*Ra

mp

33-

60Je

nis

Ram

p 3

3-61

Wak

tu N

aik

Ram

p 3

3-62

Wak

tu T

urun

Ram

p 3

3-65

Tnj.3

Ras

io t

nj-S

pd

Nai

k Pe

rc. S

tart

3-66

Tnj.3

Ras

io t

nj-S

pd

Nai

k Pe

rc. A

khir

3-67

Tnj.3

Ras

io t

nj-S

pd

Tur

un P

erc.

Sta

rt3-

68Tn

j.3 R

asio

tnj

-S p

d T

urun

Per

c. A

khir

3-7*

Ram

p 4

3-70

Jeni

s Ra

mp

43-

71W

aktu

Tan

jaka

n R

amp

43-

72W

aktu

Ram

p D

own

Ram

p 4

3-75

Tnj.4

Ras

io t

nj-S

pd

Nai

k Pe

rc. S

tart

3-76

Tnj.4

Ras

io t

nj-S

pd

Nai

k Pe

rc. A

khir

3-77

Tnj.4

Ras

io t

nj-S

pd

Tur

un P

erc.

Sta

rt3-

78Tn

j.4 R

asio

tnj

-S p

d T

urun

Per

c. A

khir

3-8*

Ram

p L

ainn

ya3-

80W

aktu

Jog

Ram

p3-

81W

aktu

Qui

ck S

top

Ram

p3-

82Je

nis

Ram

p S

top

Cep

at3-

83Ra

sio

ram

p-S

Stop

cep

at. S

tart

3-84

Rasi

o r

amp-

S St

op c

epat

. Akh

ir3-

89Ra

mp

Wak

tu F

ilter

Low

pass

3-9*

Met

er P

ot. D

igita

l3-

90U

kura

n L

angk

ah3-

91W

aktu

Aks

eler

asi-D

esel

eras

i3-

92Pe

mul

ihan

Day

a3-

93Ba

tas

Mak

sim

um3-

94Ba

tas

Min

imum

3-95

Penu

ndaa

n R

amp

4-**

Bata

s /

Peri

ngat

an4-

1*Ba

tas

Mot

or4-

10A

rah

Kec

epat

an M

otor

4-11

Bata

s Ba

wah

Kec

epat

an M

otor

[RPM

]4-

12Ba

tas

Baw

ah K

ecep

atan

Mot

or [H

z]4-

13Ba

tas

Ata

s Ke

cepa

tan

Mot

or [R

PM]

4-14

Bata

s A

tas

Kece

pata

n M

otor

[Hz]

4-16

Mod

e M

otor

Bat

as T

orsi

4-17

Mod

e G

ener

ator

Bat

as T

orsi

4-18

Bata

s A

rus

4-19

Frek

uens

i Out

put

Mak

s.4-

2*Fa

ktor

Bat

as4-

20Su

mbe

r Fa

ktor

Bat

as T

orsi

4-21

Sum

ber

Fakt

or B

atas

Kec

epat

an4-

23Su

mbe

r Fa

ktor

Bat

as P

emer

iksa

an R

em4-

24Fa

ktor

Bat

as P

emer

iksa

an R

em4-

25Su

mbe

r Fa

ktor

Mot

or B

atas

Day

a4-

26G

ener

Bat

as D

aya

Sum

ber

Fakt

or

Apendiks VLT® AutomationDrive FC 301/302

64 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

99

Page 67: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

4-3*

Mon

. Kcp

tn m

otor

4-30

Fung

si K

ehila

ngan

Um

pan

Bal

ik M

otor

4-31

Kesa

laha

n K

ecep

atan

Um

pan

Bal

ikM

otor

4-32

Tim

eout

Keh

ilang

an U

mpa

n B

alik

Mot

or4-

34Fu

ngsi

sal

ah la

cak

4-35

Sala

h P

elac

ak4-

36W

aktu

Sal

ah L

acak

hab

is4-

37Ra

mp

Sal

ah la

cak

4-38

Wak

tu R

amp

Sal

ah L

acak

Hab

is4-

39Ke

sala

han

Lac

ak S

tlh W

k Ra

mp

hab

is4-

4*M

onito

r ke

cepa

tan

4-43

Fung

si M

onito

r Ke

cepa

tan

Mot

or4-

44M

onito

r ke

cepa

tan

Mot

or M

aks

4-45

Wak

tu M

onito

r Ke

cepa

tan

Mot

or H

abis

4-5*

Sesu

ai P

erin

gata

n4-

50Pe

ringa

tan

Aru

s Re

ndah

4-51

Perin

gata

n A

rus

Ting

gi4-

52Pe

ringa

tan

Kec

epat

an R

enda

h4-

53Pe

ringa

tan

Kec

epat

an T

ingg

i4-

54Pe

ringa

tan

Ref

eren

si R

enda

h4-

55Pe

ringa

tan

Ref

eren

si T

ingg

i4-

56Pe

ringa

tan

Um

pan

Bal

ik R

enda

h4-

57Pe

ringa

tan

Um

pan

Bal

ik T

ingg

i4-

58Fu

ngsi

Fas

a M

otor

Hila

ng4-

59Pe

riksa

Mot

or S

aat

Star

t4-

6*By

pass

Kec

epat

an4-

60Ke

cepa

tan

Byp

ass

Dar

i [RP

M]

4-61

Kece

pata

n B

ypas

s D

ari [

Hz]

4-62

Kece

pata

n B

ypas

s Ke

[RPM

]4-

63Ke

cepa

tan

Byp

ass

Ke [H

z]4-

8*Ba

tas

Day

a4-

80Fu

ng B

atas

Day

a M

ode

Mot

or4-

81Fu

ng B

atas

Day

a M

ode

Gen

erat

or4-

82M

ode

Mot

or B

atas

Day

a4-

83M

ode

Gen

erat

or B

atas

Day

a4-

9*Ba

tas

Ara

h4-

90M

ode

Bata

s A

rah

4-91

Bata

s Ke

cepa

tan

Pos

itif

[RPM

]4-

92Ba

tas

Kece

pata

n P

ositi

f [H

z]4-

93Ba

tas

Kece

pata

n N

egat

if [R

PM]

4-94

Bata

s Ke

cepa

tan

Neg

atif

[Hz]

4-95

Bata

s To

rsi P

ositi

f4-

96Ba

tas

Tors

i Neg

atif

5-**

In/O

ut D

igita

l5-

0*M

ode

I/O d

igita

l5-

00M

ode

I/O D

igita

l5-

01M

ode

Term

inal

27

5-02

Mod

e Te

rmin

al 2

95-

1*In

put

Dig

ital

5-10

Inpu

t D

igita

l Ter

min

al 1

85-

11In

put

Dig

ital T

erm

inal

19

5-12

Inpu

t D

igita

l Ter

min

al 2

75-

13In

put

Dig

ital T

erm

inal

29

5-14

Inpu

t D

igita

l Ter

min

al 3

25-

15In

put

Dig

ital T

erm

inal

33

5-16

Inpu

t D

igita

l Ter

min

al X

30/2

5-17

Inpu

t D

igita

l Ter

min

al X

30/3

5-18

Inpu

t D

igita

l Ter

min

al X

30/4

5-19

Term

inal

37

Safe

Sto

p5-

20In

put

Dig

ital T

erm

inal

X46

/15-

21In

put

Dig

ital T

erm

inal

X46

/35-

22In

put

Dig

ital T

erm

inal

X46

/55-

23In

put

Dig

ital T

erm

inal

X46

/75-

24In

put

Dig

ital T

erm

inal

X46

/95-

25In

put

Dig

ital T

erm

inal

X46

/11

5-26

Inpu

t D

igita

l Ter

min

al X

46/1

35-

3*O

utpu

t D

igita

l5-

30O

utpu

t D

igita

l Ter

min

al 2

75-

31O

utpu

t D

igita

l Ter

min

al 2

95-

32O

utpu

t D

igi T

erm

X30

/6 (M

CB 1

01)

5-33

Out

put

Dig

i Ter

m X

30/7

(MCB

101

5-4*

Rela

i5-

40Re

lai F

ungs

i5-

41Tu

nda

Akt

if, R

elai

5-42

Tund

a Ti

dak

Akt

if, R

elai

5-5*

Inpu

t D

enyu

t5-

50Fr

ekue

nsi R

enda

h T

erm

. 29

5-51

Frek

uens

i Tin

ggi T

erm

. 29

5-52

Ref.R

enda

h/U

mpa

n-b

Ter

m. 2

9 N

ilai

5-53

Ref.T

ingg

i/Um

pan-

b T

erm

. 29

Nila

i5-

54Ko

nsta

nta

Wak

tu F

ilter

Pul

sa #

295-

55Fr

ekue

nsi R

enda

h T

erm

. 33

5-56

Frek

uens

i Tin

ggi T

erm

. 33

5-57

Ref.R

enda

h/U

mpa

n-b

Ter

m. 3

3 N

ilai

5-58

Ref.T

ingg

i/Um

pan-

b T

erm

. 33

Nila

i5-

59Ko

nsta

nta

Wak

tu F

ilter

Pul

sa #

335-

6*O

utpu

t D

enyu

t5-

60Va

riabe

l Out

put

Den

yut

Term

inal

27

5-62

Frek

Mak

s O

utpu

t Pu

lsa

#27

5-63

Varia

bel O

utpu

t Pu

lsa

Term

inal

29

5-65

Frek

Mak

s O

utpu

t Pu

lsa

#29

5-66

Varia

bel O

utpu

t Pu

lsa

Term

inal

X30

/65-

68Fr

ek M

aks

Out

put

Puls

a #X

30/6

5-7*

24V

Inpu

t En

kode

r5-

70D

enyu

t Pe

r Pu

tara

n T

erm

32/

335-

71A

rah

Enk

oder

Ter

m 3

2/33

5-8*

Ops

i I/O

5-80

Penu

ndaa

n R

ekon

eksi

Cap

AH

F5-

9*Bu

s Te

rkon

trol

5-90

Kont

rol B

us D

igita

l & R

elai

5-93

Kont

rol B

us O

utpu

t Pu

lsa

#27

5-94

Pres

et T

imeo

ut O

utpu

t Pu

lsa

#27

5-95

Kont

rol B

us O

utpu

t Pu

lsa

#29

5-96

Pres

et T

imeo

ut O

utpu

t Pu

lsa

#29

5-97

Kont

rol B

us O

utpu

t Pu

lsa

#X30

/65-

98Pr

eset

Tim

eout

Out

put

Puls

a #X

30/6

6-**

In/O

ut A

nalo

g6-

0*M

ode

I/O A

nalo

g6-

00W

aktu

Tim

eout

Nol

Akt

if6-

01Fu

ngsi

Tim

eout

Nol

Akt

if6-

1*In

put

Ana

log

16-

10Vo

ltase

Ren

dah

Ter

min

al 5

36-

11Vo

ltase

Tin

ggi T

erm

inal

53

6-12

Aru

s Re

ndah

Ter

min

al 5

36-

13A

rus

Ting

gi T

erm

inal

53

6-14

Ref

Rend

ah /

Um

pan-

b T

erm

inal

53

Nila

i6-

15Re

f. Ti

nggi

/ U

mpa

n-b

TEr

min

al 5

3N

ilai

6-16

Kons

tant

a W

aktu

Filt

er T

erm

inal

53

6-2*

Inpu

t an

alog

26-

20Vo

ltase

Ren

dah

Ter

min

al 5

46-

21Vo

ltase

Tin

ggi T

erm

inal

54

6-22

Aru

s Re

ndah

Ter

min

al 5

46-

23A

rus

Ting

gi T

erm

inal

54

6-24

Ref

Rend

ah /

Um

pan-

b T

erm

inal

54

Nila

i6-

25Re

f. Ti

nggi

/ U

mpa

n-b

TEr

min

al 5

4N

ilai

6-26

Kons

tant

a W

aktu

Filt

er T

erm

inal

54

6-3*

Inpu

t an

alog

36-

30Te

gang

an R

enda

h T

erm

inal

X30

/11

6-31

Volta

se T

ingg

i Ter

min

al X

30/1

16-

34Te

rm. R

ef. R

enda

h/U

mpa

n-b

X30

/11

Nila

i6-

35Te

rm. R

ef. T

ingg

i / U

mpa

n-b

X30

/11

Nila

i6-

36Te

rm. K

onst

anta

Wak

tu F

ilter

Ter

min

alX3

0/11

6-4*

Inpu

t A

nalo

g 4

6-40

Volta

se R

enda

h T

erm

inal

X30

/12

6-41

Volta

se T

ingg

i Ter

min

al X

30/1

26-

44Te

rm. R

ef. R

enda

h/U

mpa

n-b

X30

/12

Nila

i6-

45Te

rm. R

ef. T

ingg

i / U

mpa

n-b

X30

/12

Nila

i6-

46Te

rm. K

onst

anta

Wak

tu F

ilter

Ter

min

alX3

0/12

6-5*

Out

put

Ana

log

16-

50O

utpu

t Te

rmin

al 4

26-

51Sk

ala

Min

Out

put

Term

inal

42

6-52

Skal

a M

aks

Out

put

Term

inal

42

6-53

Term

42

Ktrl

Bus

Out

put

6-54

Pres

et T

imeo

ut O

utpu

t Te

rmin

al 4

26-

55Fi

lter

Out

put

Ana

log

6-6*

Out

put

anal

og 2

6-60

Out

put

Term

inal

X30

/86-

61Sk

ala

Min

. Ter

min

al X

30/8

6-62

Skal

a M

aks.

Ter

min

al X

30/8

6-63

Term

inal

x30

/8 K

ontr

ol B

us6-

64Pr

eset

Tim

eout

Out

put

Term

inal

X30

/86-

7*A

nalo

g o

utpu

t 3

6-70

Out

put

Term

inal

X45

/16-

71Sk

ala

Min

. Ter

min

al X

45/1

6-72

Skal

a M

aks.

Ter

min

al X

45/1

6-73

Kont

rol B

us T

erm

inal

X45

/16-

74Pr

eset

Tim

eout

Out

put

Term

inal

X45

/16-

8*O

utpu

t A

nalo

g 4

6-80

Out

put

Term

inal

X45

/36-

81Sk

ala

Min

. Ter

min

al X

45/3

6-82

Skal

a M

aks.

Ter

min

al X

45/3

6-83

Kont

rol B

us T

erm

inal

X45

/36-

84Pr

eset

Tim

eout

Out

put

Term

inal

X45

/37-

**Ko

ntro

ler

7-0*

Ktrl

PID

kec

epat

an7-

00Su

mbe

r U

mpa

n B

alik

PID

Kec

epat

an7-

01D

roop

Kec

epat

an P

ID7-

02G

ain

Pro

p P

ID K

ecep

atan

7-03

Wak

tu In

tegr

al P

ID K

ecep

atan

7-04

Wak

tu D

ifere

nsia

l PID

Kec

epat

an7-

05Diff. P

ID K

ecep

atan

Bat

as G

ain

7-06

Wkt

Filt

Low

pass

PID

Kec

epat

an7-

07Ra

sio

Gig

i Um

p B

lk P

ID K

ecep

atan

7-08

Fakt

or F

eed

For

war

d P

ID K

ecep

atan

7-09

Kore

ksi K

ekel

iruan

PID

kec

epat

ande

ngan

Ram

p7-

1*Kt

rl. P

I to

rsi

7-10

PI T

orsi

Sum

ber

Um

pan

Bal

ik7-

12Pe

ngua

tan

Pro

pors

iona

l PI T

orsi

7-13

Wak

tu In

tegr

asi P

I Tor

si7-

16PI

Tor

si W

aktu

Filt

er L

owpa

ss7-

18To

rsi F

akto

r Te

rusk

an U

mpa

n P

I7-

19Pe

ngon

trol

Aru

s Pe

nam

baha

n W

aktu

7-2*

Kntr

. Pr.

Pros

es7-

20Su

mbe

r U

mpa

n B

alik

1 P

rose

s CL

7-22

Sum

ber

Um

pan

Bal

ik 2

Pro

ses

CL7-

3*Ko

ntro

l Pro

ses

PID

7-30

Kont

rol N

orm

al/In

vers

e PI

D P

rose

s7-

31A

nti G

ulun

g P

rose

s PI

D7-

32Ke

cepa

tan

Aw

al P

ID K

ontr

ol7-

33G

ain

Pro

pors

iona

l PID

Pro

ses

7-34

Wak

tu In

tegr

al P

ID P

rose

s7-

35W

aktu

Pem

beda

an P

ID P

rose

s7-

36Pe

mbe

daan

PID

Pro

ses

Bata

s G

ain

7-38

Fakt

or F

eed

For

war

d P

ID P

rose

s7-

39Le

bar

Pita

Ref

eren

si A

ktif

7-4*

P'at

uran

PID

I p

rose

s7-

40Re

set

PID

Pro

ses

bagi

an I

7-41

Out

put

PID

Pro

ses

Neg

. Kle

m7-

42O

utpu

t PI

D P

rose

s Po

s. K

lem

7-43

Skal

a G

ain

PID

Pro

ses

pd R

ef. M

in.

7-44

Skal

a G

ain

PID

Pro

ses

pd R

ef. M

aks.

7-45

Feed

Fw

d P

ID P

rose

s Su

mbe

r7-

46N

orm

Fee

dFw

d P

ID N

orm

al/In

v. K

trl

Bus

7-48

Feed

For

war

d P

CD7-

49O

utpu

t PI

D P

rose

s N

orm

al/In

v. K

trl B

us7-

5*P'

atur

an L

anju

t PI

D II

7-50

PID

Eks

t, P

ID P

rose

s7-

51G

ain

Fee

d F

wd

PID

Pro

ses

7-52

Ram

p U

p F

eed

Fw

d P

ID P

rose

s7-

53Ra

mp

Dow

n F

eed

Fw

d P

ID P

rose

s7-

56PI

D P

rose

s Re

f. W

aktu

Filt

er7-

57U

b P

ID p

rose

s. W

aktu

Filt

er8-

**Ko

mun

ikas

i & O

psi

8-0*

Peng

atur

an U

mum

8-01

Titik

Kon

trol

8-02

Sum

ber

Kata

Kon

trol

8-03

Wak

tu T

ime

Out

Kat

a Ko

ntro

l8-

04Fu

ngsi

Tim

eout

Kat

a Ko

ntro

l8-

05Fu

ngsi

Akh

ir T

imeo

ut8-

06Ti

meo

ut K

ata

Kont

rol R

eset

8-07

Pem

icu

Dia

gnos

is

8-08

Peny

arin

gan

Bac

aan

8-1*

Ktrl

Bus

P'a

tur

Kata

8-10

Profi

l Kat

a Ko

ntro

l8-

13Ka

ta S

tatu

s ST

W D

apat

Dikon

figurasi

8-14

Kata

Kon

trol

CTW

dikon

figurasi

8-17

Ala

rm d

an P

erin

gata

n K

ata

Yang

Dap

atDikon

figurasi

8-19

Kode

Pro

duk

8-3*

Peng

atur

an P

ort

FC8-

30Pr

otok

ol8-

31A

lam

at8-

32Ba

ud R

ate

Port

FC

8-33

Parit

as /

Bit

Sto

p8-

34Es

timas

i sik

lus

wak

tu8-

35Tu

nda

Resp

ons

Min

imum

8-36

Tund

a Re

spon

s M

aksi

mum

8-37

Penu

ndaa

n In

ter-

Char

Mak

s8-

4*Se

t pr

otok

ol M

C F

C8-

40Pe

mili

han

Tel

egra

m8-

41Pa

ram

eter

unt

uk S

inya

l8-

42Ko

nfigu

rasi

Tul

is P

CD8-

43Ko

nfigu

rasi

Bac

a PC

D8-

45Pe

rinta

h T

rans

aksi

BTM

8-46

Stat

us T

rans

aksi

BTM

8-47

Wak

tu B

TM h

abis

8-48

Kesa

laha

n M

aksi

mum

BTM

8-49

Kesa

laha

n L

og B

TM8-

5*D

igita

l/Bus

8-50

Pem

iliha

n C

oast

ing

8-51

Pem

iliha

n B

erhe

nti C

epat

8-52

Pem

iliha

n R

em D

C8-

53Pe

mili

han

Sta

rt8-

54Pe

mili

han

Rev

ersi

8-55

Salin

an P

enga

tura

n8-

56Pi

lihan

Ref

eren

si P

rese

t8-

57Profi

drive

OFF

2 Pi

lih8-

58Profi

drive

OFF

3 Pi

lih8-

8*D

iagn

ostik

Por

t FC

8-80

Jum

lah

Pes

an B

us8-

81Ju

mla

h K

esal

ahan

Bus

8-82

Pesa

n S

lave

Dite

rima

8-83

Jum

lah

Kes

alah

an S

lave

8-9*

Bus

Jog

8-90

Kece

pata

n J

og B

us 1

8-91

Kece

pata

n J

og B

us 2

9-**

PRO

FID

rive

9-00

Setp

oint

9-07

Nila

i Akt

ual

9-15

Konfi

gurasi

Tul

is P

CD9-

16Ko

nfigu

rasi

Bac

a PC

D9-

18A

lam

at N

ode

9-19

Nom

or S

iste

m U

nit

Driv

e9-

22Pe

mili

han

Tel

egra

m9-

23Pa

ram

eter

unt

uk S

inya

l9-

27Ed

it P

aram

eter

9-28

Kont

rol P

rose

s9-

44Pe

nghi

tung

Pes

an K

esal

ahan

9-45

Kode

Mas

alah

9-47

Nom

or M

asal

ah

Apendiks Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 65

9 9

Page 68: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

9-52

Peng

hitu

ng S

ituas

i Ber

mas

alah

9-53

Kata

Per

inga

tan

Profib

us9-

63La

ju B

aud

Akt

ual

9-64

Iden

tifikasi

Pira

nti

9-65

Nom

or Profil

9-67

Kata

Kon

trol

19-

68Ka

ta S

tatu

s 1

9-70

Edit

Pen

gatu

ran

9-71

Sim

pan

Nila

i Dat

a Profi

bus

9-72

Profi

busD

riveR

eset

9-75

Iden

tifikasi

DO

9-80

Para

met

er (1

) ya

ng D

itent

ukan

9-81

Para

met

er (2

) ya

ng D

itent

ukan

9-82

Para

met

er (3

) ya

ng D

itent

ukan

9-83

Para

met

er (4

) ya

ng D

itent

ukan

9-84

Para

met

er (5

) ya

ng D

itent

ukan

9-85

Para

met

er (6

) ya

ng D

itent

ukan

9-90

Para

met

er (1

) ya

ng D

iuba

h9-

91Pa

ram

eter

(2)

yang

Diu

bah

9-92

Para

met

er (3

) ya

ng D

iuba

h9-

93Pa

ram

eter

(4)

yang

Diu

bah

9-94

Para

met

er (5

) ya

ng D

iuba

h9-

99Pe

nghi

tung

Rev

isi P

rofib

us10

-**

Fiel

dbus

CA

N10

-0*

P'at

uran

Ber

sam

a10

-00

Prot

okol

CA

N10

-01

Pem

iliha

n L

aju

Bau

d10

-02

ID M

AC10

-05

P'ht

g K

esal

ahan

Pen

girim

an P

'bac

a10

-06

P'ht

g K

esal

ahan

Pen

erim

aan

P'b

aca

10-0

7Pe

nghi

tung

Bac

aan

Bus

Off

10-1

*D

evic

eNet

10-1

0Pe

mili

han

Jen

is D

ata

Pros

es10

-11

Tulis

Kon

fig D

ata

Pros

es10

-12

Baca

Kon

fig D

ata

Pros

es10

-13

Para

met

er P

erin

gata

n10

-14

Refe

rens

i Jar

inga

n10

-15

Kont

rol J

arin

gan

10-2

*Fi

lter

COS

10-2

0Fi

lter

COS

110

-21

Filte

r CO

S 2

10-2

2Fi

lter

COS

310

-23

Filte

r CO

S 4

10-3

*A

kses

Par

amet

er10

-30

Inde

ks B

aris

10-3

1Si

mpa

n N

ilai D

ata

10-3

2Re

visi

Dev

iceN

et10

-33

Sela

lu S

impa

n10

-34

Kode

Pro

duk

Dev

iceN

et10

-39

Para

met

er D

evic

eNet

F10

-5*

CAN

open

10-5

0Tu

lis Kon

fig D

ata

Pros

es10

-51

Baca

Kon

fig D

ata

Pros

es12

-**

Ethe

rnet

12-0

*P'

atur

an IP

12-0

0Pe

nent

uan

Ala

mat

IP12

-01

Ala

mat

IP12

-02

Subn

et M

ask

12-0

3G

atew

ay D

efau

lt

12-0

4Se

rver

DH

CP12

-05

Kont

rak

Keda

luw

arsa

12-0

6N

ama

Serv

er12

-07

Nam

a D

omai

n12

-08

Nam

a H

ost

12-0

9A

lam

at F

isik

12-1

*Pa

ram

eter

Lin

k Et

hern

et12

-10

Stat

us L

ink

12-1

1D

uras

i Lin

k12

-12

Neg

osia

si O

tom

atis

12-1

3Kc

ptan

. Lin

k12

-14

Dup

lex

Link

12-1

8M

AC S

uper

viso

r12

-19

Ala

mat

IP S

uper

viso

r12

-2*

Dat

a Pr

oses

12-2

0In

stan

s Ko

ntro

l12

-21

Tulis

Kon

fig D

ata

Pros

es12

-22

Baca

Kon

fig D

ata

Pros

es12

-23

Uku

ran

Tul

is Kon

fig D

ata

Pros

es12

-24

Uku

ran

Bac

a Ko

nfig

Dat

a Pr

oses

12-2

7A

lam

at M

aste

r12

-28

Sim

pan

Nila

i Dat

a12

-29

Sela

lu S

impa

n12

-3*

Ethe

rNet

/IP12

-30

Para

met

er P

erin

gata

n12

-31

Refe

rens

i Jar

inga

n12

-32

Kont

rol J

arin

gan

12-3

3Re

visi

CIP

12-3

4Ko

de P

rodu

k CI

P12

-35

Para

met

er E

DS

12-3

7Ti

mer

CO

S In

hibi

t12

-38

Filte

r CO

S12

-4*

Mod

bus

TCP

12-4

0Pa

ram

eter

Sta

tus

12-4

1Ju

mla

h P

esan

Sla

ve12

-42

Jum

lah

Pes

an P

enge

cual

ian

Sla

ve12

-5*

Ethe

rCAT

12-5

0Ko

nfigu

rasi

Alia

s St

asiu

n12

-51

Konfi

gurasi

Ala

mat

Sta

siun

12-5

9St

atus

Eth

erCa

t12

-6*

Ethe

rnet

Pow

erLi

nk12

-60

ID N

ode

12-6

2W

aktu

SD

O h

abis

12-6

3W

aktu

Eth

erne

t D

asar

Hab

is12

-66

Am

bang

12-6

7A

mba

ng P

engh

itung

12-6

8Pe

nghi

tung

Kum

ulat

if12

-69

Stat

us P

ower

Link

Eth

erne

t12

-8*

Lay

Ethe

rnet

Lai

n12

-80

Serv

er F

TP12

-81

Serv

er H

TTP

12-8

2La

yana

n S

MTP

12-8

3Ag

en S

NM

P12

-84

Det

eksi

Kon

flik

Ala

mat

12-8

5Ko

nflik

Ter

akhi

r AC

D12

-89

Port

Sal

uran

Sok

et T

rans

para

n12

-9*

Lay

Ethe

rnet

Lan

j12

-90

Dia

gnos

tik K

abel

12-9

1Cr

oss

Ove

r O

tom

atis

12-9

2M

enca

ri IG

MP

12-9

3Pa

njan

g K

abel

Sal

ah12

-94

Prot

eksi

Bad

ai P

eman

car

12-9

5W

aktu

tid

ak a

ktif

habi

s12

-96

Konfi

g P

ort

12-9

7Pr

iorit

as Q

oS12

-98

Peng

hitu

ng A

ntar

muk

a12

-99

Peng

hitu

ng M

edia

13-*

*Sm

art

Logi

c13

-0*

Peng

atur

an S

LC13

-00

Mod

e Pe

ngon

trol

SL

13-0

1M

ulai

Per

istiw

a13

-02

Akh

iri P

eris

tiwa

13-0

3Re

set

SLC

13-1

*Pe

mba

ndin

g13

-10

Suku

Ope

rasi

Pem

band

ing

13-1

1O

pera

tor

Pem

band

ing

13-1

2N

ilai P

emba

ndin

g13

-1*

RS F

lip F

lops

13-1

5RS

-FF

Ope

rand

S13

-16

RS-F

F O

pera

nd R

13-2

*Ti

mer

13-2

0Ti

mer

Kon

trol

er S

L13

-4*

Atu

ran

Log

ik13

-40

Atu

ran

Log

ik B

oole

an 1

13-4

1O

pera

tor

Atu

ran

Log

ik 1

13-4

2A

tura

n L

ogik

Boo

lean

213

-43

Ope

rato

r A

tura

n L

ogik

213

-44

Atu

ran

Log

ik B

oole

an 3

13-5

*Ke

adaa

n13

-51

Peris

tiwa

Peng

ontr

ol S

L13

-52

Tind

akan

Pen

gont

rol S

L13

-9*

Peng

inga

t Bu

atan

Pen

ggun

a13

-90

Pem

icu

Pen

ging

at13

-91

Tind

akan

Pen

ging

at13

-92

Teks

Pen

ging

at13

-9*

Baca

an B

uata

n P

engg

una

13-9

7Ka

ta A

larm

Pen

ging

at13

-98

Kata

Per

inga

tan

Pen

ging

at13

-99

Kata

Sta

tus

Peng

inga

t14

-**

Fung

si K

husu

s14

-0*

Peny

alaa

n In

vert

er14

-00

Pola

Pen

yala

an14

-01

Frek

uens

i Pen

yala

an14

-03

Kele

biha

n m

odul

asi

14-0

4Pe

ngur

anga

n D

esis

Aku

stik

14-0

6Ko

mpe

nsas

i Wak

tu M

ati

14-1

*Ke

gaga

lan

Sum

ber

List

rik

14-1

0Ke

gaga

lan

Sum

ber

List

rik14

-11

Ting

kat

Volta

se G

angg

uan

Sum

ber

List

rik14

-12

Resp

on t

erha

dap

Ket

idak

seim

bang

anSu

mbe

r Li

strik

14-1

4W

aktu

Cad

anga

n W

aktu

Hab

is14

-15

Wak

tu C

adan

gan

Tin

gkat

Rec

over

y Tr

ip14

-16

Wak

tu C

adan

gan

Pen

guat

an14

-2*

Rese

t Tr

ip14

-20

Mod

e Re

set

14-2

1W

aktu

Res

tart

Oto

mat

is

14-2

2M

ode

Ope

rasi

14-2

3Pe

ngat

uran

Kod

e Je

nis

14-2

4Pe

nund

aan

Trip

pad

a Ba

tas

Aru

s14

-25

Penu

ndaa

n A

njlo

k pa

da B

atas

Tor

si14

-26

Penu

ndaa

n A

njlo

k sa

at In

vert

erBe

rmas

alah

14-2

8Pe

ngat

uran

Pro

duks

i14

-29

Kode

Ser

vis

14-3

*Kt

rl. B

atas

Aru

s14

-30

Ktrl.

Bts

. Aru

s, G

ain

Pro

p14

-31

Kont

rol B

atas

Aru

s, W

aktu

Inte

gras

i14

-32

Kont

rol B

atas

Aru

s, W

aktu

Filt

er14

-35

Tem

pat

Perli

ndun

gan

14-3

6Fu

ngsi

pel

emah

an a

rea

14-3

7Pe

ngur

anga

n k

ecep

atan

are

a14

-4*

Opt

imas

i Ene

rgi

14-4

0Ti

ngka

t VT

14-4

1M

agne

tisas

i Min

imum

AEO

14-4

2Fr

ekue

nsi A

EO M

inim

um14

-43

Cosp

hi M

otor

14-5

*Li

ngku

ngan

14-5

0Fi

lter

RFI

14-5

1Ko

mpe

nsas

i Lin

k-D

C14

-52

Kont

rol K

ipas

14-5

3M

onito

r Ki

pas

14-5

5Fi

lter

Out

put

14-5

6Fi

lter

Out

put

Kapa

sita

nsi

14-5

7Fi

lter

Out

put

Indu

ktan

si14

-59

Jum

lah

Akt

ual U

nit

Inve

rter

14-6

*Pe

nuru

nan

Rat

ing

Aut

o14

-60

Fung

si p

ada

Kele

biha

n S

uhu

14-6

1Fu

ngsi

saa

t In

vert

er K

eleb

ihan

Beb

an14

-62

Inv.

Aru

s Pe

nuru

nan

Rat

ing

Kel

ebih

anBe

ban

14-7

*Ke

coco

kan

14-7

2W

aris

an K

ata

Ala

rm14

-73

War

isan

Kat

a Pe

ringa

tan

14-7

4W

aris

. Eks

t. K

ata

Stat

us14

-8*

Ops

i14

-80

Ops

i dar

i 24V

DC

Eks

tern

al14

-88

Ops

i Pen

yim

pana

n D

ata

14-8

9D

etek

si O

psi

14-9

*Pe

ngat

uran

Sal

ah14

-90

Ting

kat

Kesa

laha

n15

-**

Info

rmas

i Kon

vert

er15

-0*

Dat

a O

pera

sion

al15

-00

Jam

pen

gope

rasi

an15

-01

Jam

Pen

gope

rasi

an15

-02

Peng

hitu

ng k

Wh

15-0

3Pe

nyal

aan

15-0

4Ke

lebi

han

Suh

u15

-05

Kele

b. V

olt

15-0

6Re

set

Peng

hitu

ng k

Wh

15-0

7Re

set

Peng

hitu

ng J

am P

engo

pera

sian

15-1

*Pe

ngat

. Log

Dat

a15

-10

Sum

ber

Logg

ing

15-1

1In

terv

al L

oggi

ng15

-12

Peris

tiwa

Pem

icu

15-1

3M

ode

Logg

ing

15-1

4Sa

mpe

l Seb

elum

Pem

icu

15-2

*Lo

g H

isto

ris

15-2

0Lo

g H

isto

ris: P

eris

tiwa

15-2

1Lo

g H

isto

ris: N

ilai

15-2

2Lo

g H

isto

ris: W

aktu

15-3

*Lo

g K

erus

akan

15-3

0Lo

g K

erus

akan

: Kod

e Ke

sala

han

15-3

1Lo

g K

erus

akan

: Nila

i15

-32

Log

Ker

usak

an: W

aktu

15-3

3Lo

g k

erus

akan

: Tan

ggal

dan

Jam

15-4

*Iden

tifika

si K

onve

rter

15-4

0Ti

pe F

C15

-41

Bagi

an D

aya

15-4

2Vo

ltase

15-4

3Ve

rsi P

eran

gkat

Lun

ak15

-44

Unt

ai J

enis

Kod

e Te

ruru

t15

-45

Unt

ai J

enis

Kod

e A

ktua

l15

-46

Nom

or O

rder

Kon

vert

er F

reku

ensi

15-4

7N

o O

rder

Kar

tu D

aya

15-4

8N

o ID

LCP

15-4

9Ka

rtu

Kon

trol

ID S

W15

-50

Kart

u D

aya

ID S

W15

-51

Nom

or S

eri K

onve

rter

Fre

kuen

si15

-53

No

Ser

i Kar

tu D

aya

15-5

4Ko

nfig

Nam

a Fa

il15

-58

File

nam

e Pe

ngat

uran

Sm

art

15-5

9N

ama

fail

15-6

*Id

ent

Ops

i15

-60

Ops

i Ter

pasa

ng15

-61

Vers

i Ops

i SW

15-6

2N

omor

Ord

er O

psi

15-6

3N

omor

Ser

i Ops

i15

-70

Ops

i di S

lot

A15

-71

Vers

i SW

Ops

i Slo

t A

15-7

2O

psi d

i Slo

t B

15-7

3Ve

rsi S

W O

psi S

lot

B15

-74

Ops

i di S

lot

C0/E

015

-75

Vers

i SW

Ops

i Slo

t C0

/E0

15-7

6O

psi d

i Slo

t C1

/E1

15-7

7Ve

rsi S

W O

psi S

lot

C1/E

115

-8*

Dat

a O

pera

sion

al II

15-8

0Ja

m P

engo

pera

sian

Kip

as15

-81

Jam

Pen

gope

rasi

an K

ipas

Pre

set

15-8

9Pe

ruba

han

Kon

figurasi P

engh

itung

15-9

*In

fo P

aram

eter

15-9

2Pa

ram

eter

Dite

ntuk

an15

-93

Para

met

er M

odifikasi

15-9

8Iden

tifikasi

Kon

vert

er15

-99

Met

adat

a Pa

ram

eter

16-*

*Ba

caan

Dat

a16

-0*

Stat

us U

mum

16-0

0Ka

ta K

ontr

ol16

-01

Refe

rens

i [U

nit]

16-0

2Re

fere

nsi %

16-0

3Ka

ta S

tatu

s16

-05

Nila

i Akt

ual U

tam

a [%

]16

-06

Posi

si A

ktua

l16

-09

Baca

an K

usto

m

Apendiks VLT® AutomationDrive FC 301/302

66 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

99

Page 69: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

16-1

*St

atus

Mot

or16

-10

Day

a [k

W]

16-1

1D

aya

[hp]

16-1

2Vo

ltase

Mot

or16

-13

Frek

uens

i16

-14

Aru

s m

otor

16-1

5Fr

ekue

nsi [

%]

16-1

6To

rsi [

Nm

]16

-17

Kece

pata

n [R

PM]

16-1

8Te

rmal

Mot

or16

-19

Suhu

Sen

sor

Term

isto

r16

-20

Sudu

t M

otor

16-2

1To

rsi [

%]

Res.

Tin

ggi

16-2

2To

rsi [

%]

16-2

3D

aya

Poro

s M

otor

[kW

]16

-24

Resi

stan

si S

tato

r Te

rkal

ibra

si16

-25

Tors

i [N

m]

Ting

gi16

-3*

Stat

us K

onve

rter

16-3

0Vo

ltase

DC

Lin

k16

-31

Suhu

Sis

tem

16-3

2En

ergi

Pen

gere

man

/ d

et.

16-3

3Ra

ta-r

ata

Ener

gi P

enge

rem

an16

-34

Suhu

Pen

ding

in16

-35

Term

al In

vert

er16

-36

Inv.

Nom

. Aru

s16

-37

Inv.

Aru

s M

aks.

16-3

8St

atus

Pen

gont

rol S

L16

-39

Suhu

Kar

tu K

ontr

ol16

-40

Bufe

r M

emor

i Pen

uh16

-41

Perf

oma

Peng

ukur

an16

-42

Peng

hitu

ng L

og S

ervi

s16

-43

Stat

us T

inda

kan

Ber

wak

tu16

-45

Aru

s U

Fas

a M

otor

16-4

6A

rus

V F

asa

Mot

or16

-47

Aru

s W

Fas

a M

otor

16-4

8Re

f. Ke

cepa

tan

Set

elah

Ram

p [R

PM]

16-4

9Su

mbe

r A

rus

Berm

asal

ah16

-5*

Ref.

& U

mpa

n b

alik

16-5

0Re

fere

nsi E

kste

rnal

16-5

1Re

fere

nsi P

ulsa

16-5

2U

mpa

n B

alik

[Uni

t]16

-53

Refe

rens

i Dig

i Pot

16-5

7U

mpa

n-ba

lik [R

PM]

16-6

*In

put

& O

utpu

t16

-60

Inpu

t D

igita

l16

-61

Peng

atur

an S

akla

r Te

rmin

al 5

316

-62

Inpu

t an

alog

53

16-6

3Pe

ngat

uran

Sak

lar

Term

inal

54

16-6

4In

put

anal

og 5

416

-65

Out

put

Ana

log

42

[mA

]16

-66

Out

put

Dig

ital [

bin]

16-6

7Fr

ek. I

nput

#29

[Hz]

16-6

8Fr

ek. I

nput

#33

[Hz]

16-6

9O

utpu

t Pu

lsa

#27

[Hz]

16-7

0O

utpu

t Pu

lsa

#29

[Hz]

16-7

1O

utpu

t Re

lai [

bin]

16-7

2Pe

nghi

tung

A16

-73

Peng

hitu

ng B

16-7

4Te

pat

Berh

enti

Tep

at

16-7

5In

put

Ana

log

X30

/11

16-7

6In

put

Ana

log

X30

/12

16-7

7O

utpu

t A

nalo

g X

30/8

[mA

]16

-78

Out

put

Ana

log

X45

/1 [m

A]

16-7

9O

utpu

t A

nalo

g X

45/3

[mA

]16

-8*

Fiel

dbus

& P

ort

FC16

-80

Fiel

dbus

CTW

116

-82

Fiel

dbus

REF

116

-84

Ops

i Kom

. STW

16-8

5Po

rt F

C C

TW 1

16-8

6Po

rt F

C R

EF 1

16-8

7Bu

s Re

adou

t A

larm

/Per

inga

tan

16-8

9Ko

nfigu

rasi

Ala

rm/

Perin

gata

n K

ata

16-9

*Ba

caan

Dia

gnos

is16

-90

Kata

Ala

rm16

-91

Kata

Ala

rm 2

16-9

2Ka

ta P

erin

gata

n16

-93

Kata

Per

inga

tan

216

-94

Ekst

. Kat

a St

atus

16-9

5Ek

st. K

ata

Stat

us 2

16-9

6Ka

ta P

emel

ihar

aan

17-*

*Po

sisi

Um

pan-

balik

17-1

*In

c. E

nc. A

ntar

muk

a17

-10

Jeni

s Si

nyal

17-1

1Re

solu

si (P

PR)

17-2

*A

bs. A

ntar

muk

a A

ntar

muk

a17

-20

Pem

iliha

n P

roto

kol

17-2

1Re

solu

si (P

ulsa

/Put

aran

)17

-22

Revo

lusi

mul

titur

n17

-24

Panj

ang

Dat

a SS

I17

-25

Kece

pata

n C

lock

17-2

6Fo

rmat

Dat

a SS

I17

-34

Kece

pata

n B

aud

HIP

ERFA

CE17

-5*

Ant

arm

uka

Reso

lver

17-5

0Ku

tub

17-5

1Te

gang

an In

put

17-5

2Fr

ekue

nsi I

nput

17-5

3Ra

sio

Tra

nsfo

rmas

i17

-56

Reso

lusi

Sim

. Enc

oder

17-5

9A

ntar

muk

a Re

solv

er17

-6*

Pant

au &

Apl

ikas

i17

-60

Ara

h U

mpa

n B

alik

17-6

1Pe

man

taua

n S

inya

l Um

pan

Bal

ik17

-7*

Skal

a Po

sisi

17-7

0Po

sisi

Uni

t17

-71

Posi

si S

kala

Uni

t17

-72

Posi

si N

umer

ator

Uni

t17

-73

Posi

si U

nit

Den

omin

ator

17-7

4Po

sisi

Offset

18-*

*Ba

caan

Dat

a 2

18-0

*Lo

g P

emel

ihar

aan

18-0

0Lo

g P

emel

ihar

aan:

Item

18-0

1Lo

g P

emel

ihar

aan:

Tin

daka

n18

-02

Log

Pem

elih

araa

n: W

aktu

18-0

3Lo

g P

emel

ihar

aan:

Tan

ggal

dan

Jam

18-2

*Ba

caan

Mot

or18

-27

Ops

i am

an E

st. K

ecep

atan

18-2

8O

psi a

man

Ter

ukur

Kec

epat

an18

-29

Ops

i am

an K

esal

ahan

Kec

epat

an

18-3

*Ba

caan

Ana

log

18-3

6In

put

anal

og X

48/2

[mA

]18

-37

Mod

e In

put

X48/

418

-38

Mod

e In

put

X48/

718

-39

Mod

e In

put

X48/

1018

-4*

Pem

baca

an D

ata

PGIO

18-4

3Ke

l. A

nalo

g X

49/7

18-4

4Ke

l. A

nalo

g X

49/9

18-4

5Ke

l. A

nalo

g X

49/1

118

-5*

Ala

rm/P

erin

gata

n A

ktif

18-5

5N

omor

Ala

rm A

ktif

18-5

6N

omor

Per

inga

tan

Akt

if18

-6*

Inpu

t &

Out

put

218

-60

Inpu

t D

igita

l 218

-7*

Stat

us Rek

tifier

18-7

0Vo

ltase

Sum

ber

List

rik18

-71

Frek

uens

i Sum

ber

List

rik18

-72

Ketid

akse

imba

ngan

Sum

ber

List

rik18

-75

Volt

DC

Rektifi

er18

-9*

Pem

baca

an P

ID18

-90

PID

Pro

ses

Erro

r18

-91

Out

put

PID

pro

ses

18-9

2O

utpu

t Kl

em P

ID P

rose

s18

-93

Out

put

Ters

kala

Gai

n P

ID P

rose

s22

-**

Apl

Fun

gsi

22-0

*La

in-la

in22

-00

Tund

a In

terlo

ck E

kste

rnal

23-*

*Fu

ngsi

ber

basi

s-w

aktu

23-0

*Ti

ndak

an B

erw

aktu

23-0

0W

aktu

ON

23-0

1Ti

ndak

an O

N23

-02

Wak

tu O

FF23

-03

Tind

akan

OFF

23-0

4Ke

jadi

an23

-0*

Peng

atur

an T

inda

kan

Ber

wak

tu23

-08

Mod

e Ti

ndak

an B

erw

aktu

23-0

9Re

aktif

vasi

Tin

daka

n B

erw

aktu

23-1

*Pe

raw

atan

23-1

0Ite

m P

emel

ihar

aan

23-1

1Ti

ndak

an P

emel

ihar

aan

23-1

2Ba

sis

Wak

tu P

emel

ihar

aan

23-1

3In

terv

al W

aktu

Pem

elih

araa

n23

-14

Tang

gal d

an W

aktu

Pem

elih

araa

n23

-1*

Rese

t Pe

mel

ihar

aan

23-1

5Re

set

Kata

Pem

elih

araa

n23

-16

Teks

Pem

elih

araa

n30

-**

Fitu

r Kh

usus

30-0

*W

obbl

er30

-00

Mod

e W

obbl

e30

-01

Frek

uens

i Del

ta W

obbl

e [H

z]30

-02

Frek

uens

i Del

ta W

obbl

e [%

]30

-03

Frek

. Del

ta W

obbl

e Su

mbe

r Te

ruku

r30

-04

Frek

uens

i Lom

pat

Wob

ble

[Hz]

30-0

5Fr

ekue

nsi L

ompa

t W

obbl

e [%

]30

-06

Wak

tu L

ompa

t W

obbl

e30

-07

Wak

tu U

ruta

n W

obbl

e30

-08

Wak

tu A

tas

/ Ba

wah

Wob

ble

30-0

9Fu

ngsi

Aca

k W

obbl

e30

-10

Rasi

o W

obbl

e

30-1

1Ra

sio

Aca

k W

obbl

e M

aks.

30-1

2Ra

sio

Aca

k W

obbl

e M

in.

30-1

9Fr

ek. D

elta

Wob

ble

Teru

kur

30-2

*P'

atur

an P

enye

suai

an S

tart

30-2

0W

aktu

Tor

si A

wal

Yan

g T

ingg

i [d]

30-2

1A

rus

Tors

i Aw

al Y

ang

Tin

ggi [

%]

30-2

2Pr

otek

si R

otor

Ter

kunc

i30

-23

Wak

tu D

etek

si R

otor

Ter

kunc

i [d]

30-2

4D

etek

si R

otor

Ter

kunc

i Kes

alah

anKe

cepa

tan

[%]

30-2

5Tu

nda

Beba

n R

inga

n30

-26

Aru

s Be

ban

Rin

gan

[%]

30-2

7Ke

cepa

tan

Beb

an R

inga

n [%

]30

-5*

Konfi

gurasi

Uni

t30

-50

Mod

e Ki

pas

Uni

t Pe

ndin

gin

30-8

*Ko

mpa

tibili

tas

(I)30

-80

Indu

ktan

si s

umbu

-d (L

d)30

-81

Taha

nan

Rem

(ohm

)30

-83

Gai

n P

rop

PID

Kec

epat

an30

-84

Gai

n P

ropo

rsio

nal P

ID P

rose

s30

-9*

LCP

Wifi

30-9

0SS

ID30

-91

Salu

ran

30-9

2Sa

ndi

30-9

3Ti

pe k

eam

anan

30-9

4A

lam

at IP

30-9

5Su

bmas

k30

-96

Port

30-9

7Ti

ndak

an T

imeo

ut W

ifi31

-**

Ops

i Byp

ass

31-0

0M

ode

Bypa

ss31

-01

Tund

a W

aktu

Mul

ai B

ypas

s31

-02

Tund

a W

aktu

Anj

lok

Bypa

ss31

-03

Akt

ivas

i Mod

e U

ji31

-10

Kata

Sta

tus

Bypa

ss31

-11

Jam

Pen

gope

rasi

an B

ypas

s31

-19

Akt

ivas

i Byp

ass

Jara

k Ja

uh32

-**

Peng

atur

an D

asar

MCO

32-0

*En

code

r 2

32-0

0Je

nis

Siny

al In

krem

enta

l32

-01

Reso

lusi

Inkr

emen

tal

32-0

2Pr

otok

ol A

bsol

ut32

-03

Reso

lusi

Abs

olut

32-0

4Ba

udra

te X

55 E

ncod

er A

bsol

ut32

-05

Panj

ang

Dat

a En

code

r A

bsol

ut32

-06

Frek

uens

i Clo

ck E

ncod

er A

bsol

ut32

-07

Pem

bang

kita

n J

am E

nkod

er M

utla

k32

-08

Panj

ang

Kab

el E

nkod

er A

bsol

ute

32-0

9M

onito

r en

kode

r32

-10

Ara

h R

otas

i32

-11

Den

omin

ator

Uni

t Pe

nggu

na32

-12

Pem

bila

ng U

nit

Peng

guna

32-1

3Ko

ntro

l Enc

.232

-14

ID N

ode

2 En

c.32

-15

Gua

rd C

AN

2 E

nc.

32-3

*En

code

r 1

32-3

0Je

nis

Siny

al In

krem

enta

l32

-31

Reso

lusi

Inkr

emen

tal

32-3

2Pr

otok

ol A

bsol

ut

32-3

3Re

solu

si A

bsol

ut32

-35

Panj

ang

Dat

a En

code

r A

bsol

ut32

-36

Frek

uens

i Clo

ck E

ncod

er A

bsol

ut32

-37

Pem

bang

kita

n J

am E

nkod

er M

utla

k32

-38

Panj

ang

Kab

el E

nkod

er A

bsol

ute

32-3

9M

onito

r en

kode

r32

-40

Term

inas

i Enk

oder

32-4

3Ko

ntro

l Enc

.132

-44

ID N

ote

1 En

c.32

-45

Gua

rd C

AN

1 E

nc.

32-5

*Su

mbe

r U

mpa

n-bl

k32

-50

Sour

ce S

lave

32-5

1A

kiba

t da

ri t

idak

akt

ifnya

MCO

302

32-5

2Su

mbe

r M

aste

r32

-6*

Peng

ontr

ol P

ID32

-60

Fakt

or p

ropo

rsio

nal

32-6

1Fa

ktor

Tur

unan

32-6

2Fa

ktor

Inte

gral

32-6

3N

ilai B

atas

unt

uk J

umla

h In

tegr

al32

-64

Band

wid

th P

ID32

-65

Um

pan-

Maj

u K

ecep

atan

32-6

6U

mpa

n-M

aju

Per

cepa

tan

32-6

7Ke

sala

han

Pos

isi y

ang

Dito

lera

nsi M

aks.

32-6

8Pe

rilak

u B

alik

unt

uk S

lave

32-6

9W

aktu

Sam

plin

g u

ntuk

Kon

trol

PID

32-7

0W

aktu

Sca

n u

ntuk

Profil

Gen

erat

or32

-71

Uku

ran

dar

i Jen

dela

Kon

trol

(Akt

ivas

i)32

-72

Uk.

Jnd

ela

Kont

r. (D

eakt

iv)

32-7

3W

aktu

Filt

er b

atas

inte

gral

32-7

4W

aktu

filte

r sa

lah

pos

isi

32-8

*Ke

cepa

tan

& P

erce

pata

n32

-80

Kece

pata

n M

aksi

mum

(Enc

oder

)32

-81

Ram

p T

erpe

ndek

32-8

2Je

nis

Ram

p32

-83

Reso

lusi

Kec

epat

an32

-84

Kece

pata

n S

tand

ar32

-85

Perc

epat

an S

tand

ar32

-86

Tam

bah

per

cepa

tan

unt

uk b

atas

lonj

akan

32-8

7Ku

rang

i per

cepa

tan

unt

uk b

atas

lonj

akan

32-8

8Ta

mba

h p

engu

rang

an u

ntuk

bat

aslo

njak

an32

-89

Turu

n p

engu

rang

an u

ntuk

bat

aslo

njak

an32

-9*

Perk

emba

ngan

32-9

0Su

mbe

r D

ebug

33-*

*La

njut

MCO

P'a

tura

n33

-0*

Hom

e M

otio

n33

-00

Paks

a H

OM

E33

-01

Offset

Titi

k N

ol d

ari P

os. H

ome

33-0

2Ra

mp

unt

uk H

ome

Mot

ion

33-0

3Ke

cepa

tan

unt

uk H

ome

Mot

ion

33-0

4Pe

rilak

u s

elam

a H

omeM

otio

n33

-1*

Sink

roni

sasi

33-1

0M

aste

r Fa

ktor

Sin

kr33

-11

Slav

e Fa

ktor

Sin

kr33

-12

Offset

Pos

isi u

ntuk

Sin

kron

isas

i33

-13

Jend

ela

Aku

rasi

unt

uk S

inkr

. Pos

isi

Apendiks Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 67

9 9

Page 70: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

33-1

4Ba

tas

Kece

pata

n S

lave

Rel

atif

33-1

5N

omor

Pen

anda

unt

uk M

aste

r33

-16

Nom

or P

enan

da u

ntuk

Sla

ve33

-17

Jara

k Pe

nand

a M

aste

r33

-18

Jara

k Pe

nand

a Sl

ave

33-1

9Je

nis

Pena

nda

Mas

ter

33-2

0Je

nis

Pena

nda

Slav

e33

-21

Jend

ela

Tole

rans

i Pen

anda

Mas

ter

33-2

2Je

ndel

a To

lera

nsi P

enan

da S

lave

33-2

3Pe

rilak

u M

ulai

unt

uk S

inkr

. Pen

anda

33-2

4N

omor

Pen

anda

unt

uk F

ault

33-2

5N

omor

Pen

anda

unt

uk S

iap

33-2

6Fi

lter

Kece

pata

n33

-27

Wak

tu F

ilter

Offset

33-2

8Ko

nfigu

rasi

Filt

er P

enan

da33

-29

Wak

tu F

ilter

unt

uk F

ilter

Pen

anda

33-3

0Ko

reks

i Pen

anda

Mak

sim

um33

-31

Jeni

s Si

nkro

nisa

si33

-32

Peny

esua

ian

Kec

epat

an M

aju

33-3

3W

indo

w F

ilter

Kec

epat

an33

-34

Wak

tu filte

r Pe

nand

a Sl

ave

33-4

*Pe

nang

anan

Bat

as33

-40

Peril

aku

pad

a Sa

kela

r Ba

tas

Akh

ir33

-41

Bata

s A

khir

Per

angk

at L

unak

Neg

atif

33-4

2Ba

tas

Akh

ir P

eran

gkat

Lun

ak P

ositi

f33

-43

Akt

ifk B

ts A

khir

P'a

ngka

t Lu

nak

33-4

4A

ktifk

Bts

Akh

ir P

'ang

kat

Luna

k Po

s.33

-45

Wak

tu p

ada

Jend

ela

Targ

et33

-46

Nila

i Bat

as J

ende

la T

arge

t33

-47

Uku

ran

dar

i Jen

dela

Tar

get

33-5

*Ko

nfigu

rasi

I/O

33-5

0In

put

Dig

ital T

erm

inal

X57

/133

-51

Inpu

t D

igita

l Ter

min

al X

57/2

33-5

2In

put

Dig

ital X

57/3

33-5

3In

put

Dig

ital T

erm

inal

X57

/433

-54

Inpu

t D

igita

l Ter

min

al X

57/5

33-5

5In

put

Dig

ital T

erm

inal

X57

/633

-56

Inpu

t D

igita

l Ter

min

al X

57/7

33-5

7In

put

Dig

ital T

erm

inal

X57

/833

-58

Inpu

t D

igita

l Ter

min

al X

57/9

33-5

9In

put

Dig

ital T

erm

inal

X57

/10

33-6

0Pi

lihan

pd

Ter

min

al X

59/1

dan

X59

/233

-61

Inpu

t D

igita

l Ter

min

al X

59/1

33-6

2In

put

Dig

ital T

erm

inal

X59

/233

-63

Out

put

Dig

ital T

erm

inal

X59

/133

-64

Out

put

Dig

ital T

erm

inal

X59

/233

-65

Out

put

Dig

ital T

erm

inal

X59

/333

-66

Out

put

Dig

ital T

erm

inal

X59

/433

-67

Out

put

Dig

ital T

erm

inal

X59

/533

-68

Out

put

Dig

ital T

erm

inal

X59

/633

-69

Out

put

Dig

ital T

erm

inal

X59

/733

-70

Out

put

Dig

ital T

erm

inal

X59

/833

-8*

Para

met

er G

loba

l33

-80

Nom

or P

rogr

am y

ang

Dia

ktifk

an33

-81

Stat

us P

ower

-up

33-8

2M

onito

r St

atus

Driv

e33

-83

Peril

aku

set

elah

Err

or33

-84

Peril

aku

set

elah

Esc

.33

-85

MCO

Dis

upla

i ole

h 2

4VD

C E

kste

rnal

33-8

6Te

rmin

al p

ada

alar

m33

-87

Stat

e te

rmin

al p

ada

alar

m33

-88

Stat

us k

ata

pada

ala

rm33

-9*

Peng

atur

an P

ort

MCO

33-9

0ID

nod

e CA

N M

CO X

6233

-91

Baud

rat

e CA

N M

CO X

6233

-94

Pem

utus

an s

eria

l RS4

85 M

CO X

6033

-95

Baud

rat

e se

rial R

S485

MCO

X60

34-*

*P'

baca

Dat

a M

CO34

-0*

Par.

Tulis

PCD

34-0

1Tu

lis P

CD 1

dar

i MCO

34-0

2Tu

lis P

CD 2

dar

i MCO

34-0

3Tu

lis P

CD 3

dar

i MCO

34-0

4Tu

lis P

CD 4

dar

i MCO

34-0

5Tu

lis P

CD 5

dar

i MCO

34-0

6Tu

lis P

CD 6

dar

i MCO

34-0

7Tu

lis P

CD 7

dar

i MCO

34-0

8Tu

lis P

CD 8

dar

i MCO

34-0

9Tu

lis P

CD 9

dar

i MCO

34-1

0Tu

lis P

CD 1

0 da

ri M

CO34

-2*

Par.

Baca

PCD

34-2

1Ba

ca P

CD 1

dar

i MCO

34-2

2Ba

ca P

CD 2

dar

i MCO

34-2

3Ba

ca P

CD 3

dar

i MCO

34-2

4Ba

ca P

CD 4

dar

i MCO

34-2

5Ba

ca P

CD 5

dar

i MCO

34-2

6Ba

ca P

CD 6

dar

i MCO

34-2

7Ba

ca P

CD 7

dar

i MCO

34-2

8Ba

ca P

CD 8

dar

i MCO

34-2

9Ba

ca P

CD 9

dar

i MCO

34-3

0Ba

ca P

CD 1

0 da

ri M

CO34

-4*

Inpu

t &

Out

put

34-4

0In

put

Dig

ital

34-4

1O

utpu

t D

igita

l34

-5*

Dat

a Pr

oses

34-5

0Po

sisi

Akt

ual

34-5

1Po

sisi

yan

g D

iper

inta

hkan

34-5

2Po

sisi

Mas

ter

Sebe

narn

ya34

-53

Posi

si In

deks

Sla

ve34

-54

Posi

si In

deks

Mas

ter

34-5

5Po

sisi

Kur

va34

-56

Laca

k Ke

sala

han

34-5

7M

ensi

nkro

nkan

Kes

alah

an34

-58

Kece

pata

n S

eben

arny

a34

-59

Kece

pata

n M

aste

r Se

bena

rnya

34-6

0M

ensi

nkro

nkan

Sta

tus

34-6

1St

atus

Sum

bu34

-62

Stat

us P

rogr

am34

-64

Stat

us M

CO 3

0234

-65

Kont

rol M

CO 3

0234

-66

Kesa

laha

n P

engh

itung

SPI

34-7

*P'

baca

an d

iagn

osa

34-7

0M

CO K

ata

Ala

rm 1

34-7

1M

CO K

ata

Ala

rm 2

35-*

*O

psi I

nput

Sen

sor

35-0

*M

ode

Mod

e In

put

35-0

0Te

rm. U

nit

Suhu

X48

/435

-01

Term

. Tip

e In

put

X48/

435

-02

Term

. Uni

t Su

hu X

48/7

35-0

3Te

rm. T

ipe

Inpu

t X4

8/7

35-0

4Te

rm. U

nit

Suhu

X48

/10

35-0

5Te

rm. T

ipe

Inpu

t X4

8/10

35-0

6Fu

ngsi

Ala

rm S

enso

r Su

hu35

-1*

Mod

e In

put

X48/

435

-14

Term

. Kon

stan

ta W

aktu

Filt

er X

48/4

35-1

5Te

rm. X

48/4

Mon

itor

Mon

itor

35-1

6Te

rm. B

atas

Suh

u R

enda

h X

48/4

Bat

as35

-17

Term

. Suh

u T

ingg

i X48

/4 B

atas

35-2

*M

ode

Inpu

t X4

8/7

35-2

4Te

rm. K

onst

anta

Wak

tu F

ilter

X48

/735

-25

Term

. Mon

itor

Suhu

X48

/7 M

onito

r35

-26

Term

. Bat

as S

uhu

Ren

dah

X48

/7 B

atas

35-2

7Te

rm. S

uhu

Tin

ggi X

48/7

Bat

as35

-3*

Mod

e In

put

X48/

1035

-34

Term

. Kon

stan

ta W

aktu

Filt

er X

48/1

035

-35

Term

. Suh

u X

48/1

0 M

onito

r35

-36

Term

. Suh

u R

enda

h X

48/1

0 Ba

tas

35-3

7Te

rm. S

uhu

Tin

ggi X

48/1

0 Ba

tas

35-4

*In

put

Ana

log

X48

/235

-42

Term

. Aru

s Re

ndah

Ter

min

al X

48/2

35-4

3Te

rm. A

rus

Ting

gi X

48/2

35-4

4Te

rm. R

ef. R

enda

h/U

mpa

n-b

X48

/2N

ilai

35-4

5Te

rm. R

ef. T

ingg

i / U

mpa

n-b

X48

/2N

ilai

35-4

6Te

rm. K

onst

anta

Wak

tu F

ilter

X48

/236

-**

Ops

i I/O

Ter

prog

ram

36-0

*M

ode

I/O36

-03

Mod

e Te

rmin

al X

49/7

36-0

4M

ode

Term

inal

X49

/936

-05

Mod

e Te

rmin

al X

49/1

136

-4*

X49/

7 O

utpu

t36

-40

Term

inal

X49

/7 O

utpu

t A

nalo

g36

-42

Term

inal

X49

/7 S

kala

Min

36-4

3Te

rmin

al X

49/7

Ska

la M

aks

36-4

4Te

rmin

al x

49/7

Kon

trol

Bus

36-4

5Pr

a-se

tel T

imeo

ut T

erm

inal

X49

/736

-5*

Out

put

X49/

936

-50

Term

inal

X49

/9 O

utpu

t an

alog

36-5

2Te

rmin

al X

49/9

Ska

la M

in36

-53

Term

inal

X49

/9 S

kala

Mak

s36

-54

Term

inal

x49

/9 K

ontr

ol B

us36

-55

Pra-

sete

l Tim

eout

Ter

min

al X

49/9

36-6

*O

utpu

t X4

9/11

36-6

0Te

rmin

al X

49/1

1 O

utpu

t A

nalo

g36

-62

Term

inal

X49

/11

Skal

a M

in36

-63

Term

inal

X49

/11

Skal

a M

aks

36-6

4Te

rmin

al x

49/1

1 Ko

ntro

l Bus

36-6

5Pr

a-se

tel T

imeo

ut T

erm

inal

X49

/11

40-*

*Pe

ngat

uran

Khu

sus

40-4

*Ek

sten

si L

og K

erus

akan

40-4

0Lo

g K

erus

akan

: Eks

t. R

efer

ensi

40-4

1Lo

g K

erus

akan

: Fre

kuen

si40

-42

Log

Ker

usak

an: A

rus

40-4

3Lo

g K

erus

akan

: Vol

tase

40-4

4Lo

g K

erus

akan

: Vol

tase

DC

Lin

k40

-45

Log

Ker

usak

an: K

ata

Kont

rol

40-4

6Lo

g K

erus

akan

: Kat

a St

atus

40-5

*Pe

ngat

uran

Kon

trol

Lan

jut

40-5

0Pe

ruba

han

Mod

el F

lux

Sens

orle

ss40

-51

Kor

Flux

Sen

sorle

ss P

engu

atan

42-*

*Fu

ngsi

Kes

elam

atan

42-1

*Pe

man

taua

n K

ecep

atan

42-1

0Su

mbe

r Ke

cepa

tan

Yan

g T

eruk

ur42

-11

Reso

lusi

Enk

oder

42-1

2A

rah

Enk

oder

42-1

3Pe

rban

ding

an G

igi

42-1

4Je

nis

Um

pan-

balik

42-1

5Fi

lter

Um

pan-

balik

42-1

7To

lera

nsi K

esal

ahan

42-1

8W

aktu

Kec

epat

an N

ol42

-19

Bata

s Ke

cepa

tan

Nol

42-2

*In

put

Am

an42

-20

Fung

si A

man

42-2

1Je

nis

42-2

2Pe

rbed

aan

Wak

tu42

-23

Wak

tu S

inya

l Sta

bil

42-2

4A

tura

n P

engu

lang

an42

-3*

Um

um42

-30

Reak

si K

egag

alan

Eks

tern

al42

-31

Rese

t Su

mbe

r42

-33

Nam

a Pe

ngat

uran

Par

amet

er42

-35

Nila

i S-C

RC42

-36

Ting

kat

1 Sa

ndi

42-3

7Bu

ffer

Sand

i Tin

gkat

142

-4*

SS1

42-4

0Je

nis

42-4

1Profi

l Ram

p42

-42

Wak

tu T

unda

42-4

3D

elta

T42

-44

Laju

Per

lam

bata

n42

-45

Del

ta V

42-4

6Ke

cepa

tan

Nol

42-4

7W

aktu

Aks

eler

asi-D

esel

eras

i42

-48

Rasi

o r

amp-

s pa

da p

enur

unan

Sta

rt42

-49

Rasi

o r

amp-

s pa

da p

enur

unan

Akh

ir42

-5*

SLS

42-5

0Pu

tusk

an K

ecep

atan

42-5

1Ba

tas

Kece

pata

n42

-52

Reak

si A

man

Gag

al42

-53

Mem

ulai

Ram

p42

-54

Wak

tu P

enur

unan

42-6

*Fi

eldb

us A

man

42-6

0Pe

mili

han

Tel

egra

m42

-61

Ala

mat

Tuj

uan

42-8

*St

atus

42-8

0St

atus

Ops

i Yan

g A

man

42-8

1St

atus

Ops

i Am

an 2

42-8

2Ka

ta K

ontr

ol A

man

42-8

3Ka

ta S

tatu

s A

man

42-8

5Fu

ngsi

Am

an A

ktif

42-8

6In

fo O

psi Y

ang

Am

an42

-87

Wak

tu s

ampa

i Pen

gujia

n M

anua

l42

-88

Did

ukun

g V

ersi

File

Per

ubah

an42

-89

Vers

i File

Per

ubah

an42

-9*

Khus

us42

-90

Mul

ai O

psi A

man

Kem

bali

43-*

*Ba

caan

Uni

t43

-0*

Stat

us K

ompo

nen

43-0

0Su

hu K

ompo

nen

43-0

1Su

hu A

uksi

ler

43-0

2SW

-ID K

ompo

nen

43-1

*St

atus

Kar

tu D

aya

43-1

0Su

hu H

S ph

.U43

-11

Suhu

HS

ph.V

43-1

2Su

hu H

S ph

.W43

-13

Kece

pata

n K

ipas

A P

C43

-14

Kece

pata

n K

ipas

B P

C43

-15

Kece

pata

n K

ipas

C P

C43

-2*

Stat

us K

artu

Day

a Ki

pas

43-2

0Ke

cepa

tan

Kip

as A

FPC

43-2

1Ke

cepa

tan

Kip

as B

FPC

43-2

2Ke

cepa

tan

Kip

as C

FPC

43-2

3Ke

cepa

tan

Kip

as D

FPC

43-2

4Ke

cepa

tan

Kip

as E

FPC

43-2

5Ke

cepa

tan

Kip

as F

FPC

600-

**PR

OFI

safe

600-

22PR

OFI

driv

e/Te

l am

an. T

erpi

lih60

0-44

Peng

hitu

ng P

esan

Kes

alah

an60

0-47

Nom

or M

asal

ah60

0-52

Peng

hitu

ng S

ituas

i Ber

mas

alah

601-

**PR

OFI

driv

e 2

601-

22PR

OFI

driv

e Ke

sela

mat

an S

alur

an T

el.

No.

Apendiks VLT® AutomationDrive FC 301/302

68 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

99

Page 71: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

9.2.

2St

rukt

ur M

enu

Para

met

er

0-**

Ope

rasi

/Tam

pila

n0-

0*Pe

ngat

uran

Das

ar0-

01Ba

hasa

0-02

Uni

t Ke

cepa

tan

Mot

or0-

03Pe

ngat

uran

Wila

yah

0-04

Kete

rang

an P

'ope

rasi

an s

aat

peny

ala

0-09

Perf

orm

ance

Mon

itor

0-1*

Ope

rasi

Pen

gatu

ran

0-10

Peng

atur

an a

ktif

0-11

Edit

pen

gatu

ran

0-12

Peng

atur

an in

i Ber

hubu

ngan

ke

0-13

Pem

baca

an: P

enga

tura

n t

erhu

bung

0-14

Pem

baca

an: E

dit

Peng

atur

an /

Sal

uran

0-15

Read

out:

act

ual s

etup

0-2*

Tam

pila

n L

CP0-

20Ta

mpi

lan

Bar

is 1

,1 K

ecil

0-21

Tam

pila

n B

aris

1,2

Kec

il0-

22Ta

mpi

lan

Bar

is 1

,3 K

ecil

0-23

Tam

pila

n B

aris

2 B

esar

0-24

Tam

pila

n B

aris

3 B

esar

0-25

Men

u P

ribad

iku

0-3*

Pbac

a. C

ust.

LCP

0-30

Uni

t ut

k Pb

acaa

n y

g D

itent

u. P

'gun

a0-

31N

ilai M

in. P

'bac

aan

Dite

nt. S

endi

ri0-

32N

ilai M

aks.

dar

i Pem

baca

an S

endi

ri0-

33So

urce

for User-de

fined

Rea

dout

0-37

Teks

Tam

pila

n 1

0-38

Teks

Tam

pila

n 2

0-39

Teks

Tam

pila

n 3

0-4*

Tom

bol L

CP0-

40[M

anua

l] to

mbo

l pd

LCP

0-41

[Off]

tom

bol p

d L

CP0-

42(N

yala

Oto

mat

is)

Tom

bol p

ada

LCP

0-43

[Res

et]

tom

bol p

d L

CP0-

44To

mbo

l [Off/Re

set]

pad

a LC

P0-

45Ku

nci [

Bypa

ss D

rive]

pad

a LC

P0-

5*Co

py/s

impa

n0-

50Co

py L

CP0-

51Co

py P

enga

tura

n0-

6*Ka

ta S

andi

0-60

Kt. s

andi

Men

u U

tam

a0-

61A

kses

ke

Men

u U

tam

a ta

npa

kt. S

andi

0-65

Kt. S

andi

Men

u C

epat

0-66

Aks

es k

e M

enu

Cep

at t

anpa

kt.

San

di0-

67A

kses

Kat

a Sa

ndi B

us0-

68Sa

fety

Par

amet

ers

Pass

wor

d0-

69Pa

ssw

ord

Pro

tect

ion

of

Safe

tyPa

ram

eter

s1-

**Be

ban

dan

Mot

or1-

0*Pe

ngat

uran

Um

um1-

00M

ode Ko

nfigu

rasi

1-01

Das

ar k

ontr

ol M

otor

1-02

Sum

ber

Um

pan

Bal

ik M

otor

Flu

ks1-

03Ka

rakt

eris

tik T

orsi

1-04

Mod

us k

eleb

ihan

beb

an

1-05

Konfi

gurasi

Mod

e Lo

kal

1-06

Sear

ah J

arum

Jam

1-07

Mot

or A

ngle

Offset

Adj

ust

1-1*

Pem

iliha

n M

otor

1-10

Kons

truk

si M

otor

1-11

Mot

or M

odel

1-18

Min

. Cur

rent

at

No

Loa

d1-

2*D

ata

Mot

or1-

20D

aya

Mot

or [k

W]

1-21

Day

a m

otor

[HP]

1-22

Tega

ngan

Mot

or1-

23Fr

ekue

nsi M

otor

1-24

Aru

s M

otor

1-25

Kece

pata

n N

omin

al M

otor

1-26

Tors

i Ter

ukur

Kon

trol

Mot

or1-

29Pe

nyes

uaia

n M

otor

Oto

mat

is (A

MA

)1-

3*L'j

utan

Dat

a M

oto

1-30

Resi

stan

si S

tato

r (R

s)1-

31Re

sist

ansi

Rot

or (R

r)1-

33Re

akta

nsi K

eboc

oran

Sta

tor

(X1)

1-34

Reak

tans

i Keb

ocor

an R

otor

(X2)

1-35

Reak

tans

i Uta

ma

(Xh)

1-36

Resi

stan

si K

erug

ian

Bes

i (Rf

e)1-

37In

dukt

ansi

sum

bu-d

(Ld)

1-38

q-ax

is In

duct

ance

(Lq)

1-39

Kutu

b M

otor

1-40

EMF

Balik

pad

a 10

00 R

PM1-

41Offset

Sud

ut M

otor

1-44

d-ax

is In

duct

ance

Sat

. (Ld

Sat)

1-45

q-ax

is In

duct

ance

Sat

. (Lq

Sat)

1-46

Posi

tion

Det

ectio

n G

ain

1-47

Torq

ue C

alib

ratio

n1-

48d-

axis

Indu

ctan

ce S

at. P

oint

1-49

q-ax

is In

duct

ance

Sat

. Poi

nt1-

5*T.

T'g

ant.

beb

an1-

50M

agne

tisas

i mot

or p

ada

Kece

pata

n N

ol1-

51M

gnet

. Nor

m. K

ec. M

in. [

RPM

]1-

52M

agne

t. N

orm

. Kec

. Min

. [H

z]1-

53Fr

ekue

nsi G

eser

Mod

el1-

54Vo

ltage

redu

ctio

n in

fieldw

eakening

1-55

Kara

kter

istik

U/f

- U

1-56

Kara

kter

istik

U/f

- F

1-57

Torq

ue E

stim

atio

n T

ime

Cons

tant

1-58

Flyi

ng S

tart

Tes

t Pu

lses

Cur

rent

1-59

Flyi

ng S

tart

Tes

t Pu

lses

Fre

quen

cy1-

6*T'

gant

Bbn

P'a

tur

1-60

Kom

pens

asi B

eban

Kec

epat

an R

enda

h1-

61Ko

mpe

nsas

i Beb

an K

ecep

atan

Tin

ggi

1-62

Kom

pens

asi S

lip1-

63Te

tapa

n W

aktu

Kom

pens

asi S

lip1-

64Pe

reda

man

Res

onan

si1-

65Te

tapa

n W

aktu

per

edam

an r

eson

ansi

1-66

Aru

s m

in. p

ada

Kece

pata

n R

enda

h1-

67Je

nis

Beba

n1-

68In

ersi

a M

inim

um1-

69In

ersi

a M

aksi

mum

1-7*

Peny

esua

ian

Sta

rt1-

70PM

Sta

rt M

ode

1-71

Penu

ndaa

n s

tart

1-72

Fung

si s

tart

1-73

Flyi

ng S

tart

1-74

Kece

pata

n s

tart

[RPM

]1-

75Ke

cepa

tan

Sta

rt [H

z]1-

76A

rus

Star

t1-

8*St

op p

enye

suai

an1-

80Fu

ngsi

saa

t St

op1-

81Fu

ngsi

dar

i kcp

tn. m

in. p

d s

top

[RPM

]1-

82Ke

c. M

in u

tk F

ungs

i B'h

enti

[Hz]

1-9*

Suhu

Mot

or1-

90Pr

otek

si p

d t

erm

al m

otor

1-91

Kipa

s Ek

ster

nal M

otor

1-93

Sum

ber

Term

isto

r1-

94AT

EX E

TR c

ur.li

m. s

peed

redu

ctio

n1-

95Je

nis

Sens

or K

TY1-

96Su

mbe

r Te

rmis

tor

KTY

1-97

Ting

kat

Am

bang

KTY

1-98

ATEX

ETR

inte

rpol

. poi

nts

freq

.1-

99AT

EX E

TR in

terp

ol p

oint

s cu

rren

t2-

**Br

ake

2-0*

Brak

e D

C2-

00A

rus

Pena

han

DC

2-01

Aru

s Br

ake

DC

2-02

Wak

tu P

enge

rem

an D

C2-

03Ke

cepa

tan

Pen

yela

an R

em D

C [R

PM]

2-04

Kece

pata

n P

enye

laan

Rem

DC

[Hz]

2-05

Refe

rens

i Mak

sim

um2-

06Pa

rkin

g C

urre

nt2-

07Pa

rkin

g T

ime

2-1*

Fung

si E

nerg

i Bra

ke2-

10Fu

ngsi

Bra

ke2-

11Ta

hana

n B

rake

2-12

Bata

s D

aya

Brak

e (k

W)

2-13

Pem

anta

uan

Day

a Br

ake

2-15

Cek

Brak

e2-

16A

rus

Mak

s. re

m A

C2-

17Pe

ngon

trol

teg

anga

n b

erle

bih

2-18

Perik

sa K

ondi

si R

em2-

19O

ver-

volta

ge G

ain

2-2*

Brak

e m

ekan

is2-

20A

rus

pele

pas

Brak

e2-

21A

ktifk

an K

ecep

atan

Bra

ke/R

em [R

PM]

2-22

Men

gakt

ifkan

Kec

epat

an B

rake

[Hz]

2-23

Akt

ifkan

Pen

unda

an B

rake

/Rem

2-24

Stop

del

ay2-

25W

aktu

Pel

epas

an R

em2-

26Re

f. To

rsi

2-27

Wak

tu R

amp

Tor

si2-

28Fa

ktor

Boo

st P

erol

ehan

2-29

Torq

ue R

amp

Dow

n T

ime

2-3*

Adv

. Mec

h B

rake

2-30

Posi

tion

P S

tart

Pro

port

iona

l Gai

n2-

31Sp

eed

PID

Sta

rt P

ropo

rtio

nal G

ain

2-32

Spee

d P

ID S

tart

Inte

gral

Tim

e2-

33Sp

eed

PID

Sta

rt L

owpa

ss F

ilter

Tim

e2-

34Ze

ro S

peed

Pos

ition

P P

ropo

rtio

nal

Gai

n3-

**Re

fere

nsi /

Ram

p3-

0*Ba

tas

Refe

rens

i

3-00

Caku

pan

Ref

eren

si3-

01U

nit

Refe

rens

i/Um

pan

Bal

ik3-

02Re

fere

nsi M

inim

um3-

03Re

fere

nsi M

aksi

mum

3-04

Fung

si R

efer

ensi

3-05

On

Ref

eren

ce W

indo

w3-

06M

inim

um P

ositi

on3-

07M

axim

um P

ositi

on3-

08O

n T

arge

t W

indo

w3-

09O

n T

arge

t Ti

me

3-1*

Refe

renc

es3-

10Re

fere

nsi p

rese

t3-

11Ke

cepa

tan

Jog

[Hz]

3-12

Nila

i Pen

geja

ran/

Perla

mba

tan

3-13

Situ

s Re

fere

nsi

3-14

Refe

rens

i rel

atif

pres

et3-

15Su

mbe

r Re

fere

nsi 1

3-16

Sum

ber

Refe

rens

i 23-

17Su

mbe

r Re

fere

nsi 3

3-18

Sum

ber

Refe

rens

i Pen

-ska

la-a

n R

elat

if3-

19Ke

cepa

tan

Jog

[RPM

]3-

2*Re

fere

nces

II3-

20Pr

eset

Tar

get

3-21

Touc

h T

arge

t3-

22M

aste

r Sc

ale

Num

erat

or3-

23M

aste

r Sc

ale

Den

omin

ator

3-24

Mas

ter

Low

pass

Filt

er T

ime

3-25

Mas

ter

Bus

Reso

lutio

n3-

26M

aste

r Offset

3-27

Virt

ual M

aste

r M

ax R

ef3-

28M

aste

r Offset

Spe

ed R

ef3-

4*Ra

mp

13-

40Je

nis

Ram

p 1

3-41

Wak

tu t

anja

kan

Ram

p 1

3-42

Wak

tu T

urun

an R

amp

13-

45Tn

j.1 R

asio

tnj

-S p

d A

wal

Nai

k Pe

rc.

3-46

Tnj.1

Ras

io t

nj-S

pd

Akh

. Nai

k Pe

rc.

3-47

Tnj.1

Ras

io t

nj-S

pd

Aw

al T

urun

Per

c.3-

48Tn

j.1 R

asio

tnj

-S p

d A

kh. T

urun

Per

c.3-

5*Ra

mp

23-

50Je

nis

Ram

p 2

3-51

Wak

tu t

anja

kan

Ram

p 2

3-52

Wak

tu T

urun

an R

amp

23-

55Tn

j.2 R

asio

tnj

-S p

d A

wal

Nai

k Pe

rc.

3-56

Tnj.2

Ras

io t

nj-S

pd

Akh

. Nai

k Pe

rc.

3-57

Tnj.2

Ras

io t

nj-S

pd

Aw

al T

urun

Per

c.3-

58Tn

j.2 R

asio

tnj

-S p

d A

kh. T

urun

Per

c.3-

6*Ra

mp

33-

60Je

nis

Ram

p 3

3-61

Wak

tu t

anja

kan

Ram

p 3

3-62

Wak

tu T

urun

an R

amp

33-

65Tn

j.3 R

asio

tnj

-S p

d A

wal

Nai

k Pe

rc.

3-66

Tnj.3

Ras

io t

nj-S

pd

Akh

. Nai

k Pe

rc.

3-67

Tnj.3

Ras

io t

nj-S

pd

Aw

al T

urun

Per

c.3-

68Tn

j.3 R

asio

tnj

-S p

d A

kh. T

urun

Per

c.3-

7*Ra

mp

43-

70Je

nis

Ram

p 4

3-71

Wak

tu t

anja

kan

Ram

p 4

3-72

Wak

tu T

urun

an R

amp

4

3-75

Tnj.4

Ras

io t

nj-S

pd

Aw

al N

aik

Perc

.3-

76Tn

j.4 R

asio

tnj

-S p

d A

kh. N

aik

Perc

.3-

77Tn

j.4 R

asio

tnj

-S p

d A

wal

Tur

un P

erc.

3-78

Tnj.4

Ras

io t

nj-S

pd

Akh

. Tur

un P

erc.

3-8*

Ram

p la

in3-

80W

aktu

Ram

p J

og3-

81W

aktu

Ram

p S

top

Cep

at3-

82Je

nis

Ram

p S

top

Cep

at3-

83Ra

sio

ram

p-S

Stop

cep

at. S

tart

3-84

Rasi

o r

amp-

S St

op c

epat

. Akh

ir3-

89Ra

mp

Low

pass

Filt

er T

ime

3-9*

Pot.m

eter

Dig

ital

3-90

Uku

ran

ste

p3-

91Ra

mp

Tim

e3-

92Pe

mul

ihan

Day

a3-

93Ba

tas

Mak

sim

um3-

94Ba

tas

Min

imum

3-95

Penu

ndaa

n T

anja

kan

4-**

Bata

s /

Peri

ngat

an4-

1*Ba

tas

Mot

or4-

10A

rah

Kec

epat

an M

otor

4-11

Bata

san

Ren

dah

Kec

epat

an M

otor

[RPM

]4-

12Ba

tasa

n R

enda

h K

ecep

atan

Mot

or [H

z]4-

13Ba

tasa

n T

ingg

i Kec

epat

an M

otor

[RPM

]4-

14Ba

tasa

n T

ingg

i Kec

epat

an M

otor

[Hz]

4-16

Mod

e M

otor

Bat

asan

Tor

si4-

17M

ode

gene

rato

r Ba

tasa

n T

orsi

4-18

Bata

s A

rus

4-19

Frek

uens

i Out

put

Mak

s.4-

2*Fa

ktor

Bat

as4-

20Su

mbe

r Fa

ktor

Bat

as T

orsi

4-21

Sum

ber

Fakt

or B

atas

Kec

epat

an4-

23Br

ake

Chec

k Li

mit

Fac

tor

Sour

ce4-

24Br

ake

Chec

k Li

mit

Fac

tor

4-3*

Mon

. Kcp

tn m

otor

4-30

Fung

si R

ugi U

mpa

n-ba

lik M

otor

4-31

Kesa

laha

n K

ecep

atan

Um

pan-

balik

Mot

or4-

32Ti

meo

ut R

ugi U

mpa

n-ba

lik M

otor

4-34

Fung

si s

alah

laca

k4-

35Sa

lah

Pel

acak

4-36

Wak

tu S

alah

Lac

ak h

abis

4-37

Ram

p S

alah

laca

k4-

38W

aktu

Ram

p S

alah

Lac

ak H

abis

4-39

Kesa

laha

n L

acak

Stlh

Wk

Ram

p h

abis

4-4*

Spee

d M

onito

r4-

43M

otor

Spe

ed M

onito

r Fu

nctio

n4-

44M

otor

Spe

ed M

onito

r M

ax4-

45M

otor

Spe

ed M

onito

r Ti

meo

ut4-

5*Se

suai

Per

inga

tan

4-50

Aru

s Pe

ringa

tan

Lem

ah4-

51A

rus

Perin

gata

n T

ingg

i4-

52Ke

cepa

tan

Per

inga

tan

Ren

dah

4-53

Kece

pata

n P

erin

gata

n T

ingg

i4-

54Pe

ringa

tan

Ref

eren

si R

enda

h4-

55Pe

ringa

tan

Ref

eren

si T

ingg

i4-

56Pe

ringa

tan

Um

pan

Bal

ik R

enda

h4-

57Pe

ringa

tan

Um

pan

Bal

ik T

ingg

i

Apendiks Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 69

9 9

Page 72: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

4-58

Fung

si F

asa

Mot

or H

ilang

4-6*

Kece

pata

n p

inta

s4-

60Ke

cepa

tan

Pin

tas

Dar

i [RP

M]

4-61

Kece

pata

n P

inta

s D

ari [

Hz]

4-62

Kece

pata

n P

inta

s ke

[RPM

]4-

63Ke

cepa

tan

Pin

tas

Ke [H

z]4-

7*Po

sitio

n M

onito

r4-

70Po

sitio

n E

rror

Fun

ctio

n4-

71M

axim

um P

ositi

on E

rror

4-72

Posi

tion

Err

or T

imeo

ut4-

73Po

sitio

n L

imit

Fun

ctio

n4-

74St

art

Fwd/

Rev

Func

tion

4-75

Touc

h T

imou

t5-

**D

igita

l In/

Out

5-0*

Mod

e I/O

dig

ital

5-00

Mod

e I/O

Dig

ital

5-01

Mod

e Te

rmin

al 2

75-

02Te

rmin

al 2

9 M

ode

5-1*

Dig

ital I

nput

5-10

Term

inal

18

Inpu

t D

igita

l5-

11Te

rmin

al 1

9 In

put

Dig

ital

5-12

Term

inal

27

Inpu

t D

igita

l5-

13Te

rmin

al 2

9 In

put

Dig

ital

5-14

Term

inal

32

Inpu

t D

igita

l5-

15Te

rmin

al 3

3 In

put

Dig

ital

5-16

Inpu

t D

igita

l Ter

min

al X

30/2

5-17

Inpu

t D

igita

l Ter

min

al X

30/3

5-18

Inpu

t D

igita

l Ter

min

al X

30/4

5-19

Term

inal

37

Berh

enti

Am

an5-

20Te

rmin

al x

46/1

Mas

ukan

Dig

ital

5-21

Term

inal

x46

/3 M

asuk

an D

igita

l5-

22Te

rmin

al x

46/5

Mas

ukan

Dig

ital

5-23

Term

inal

x46

/7 M

asuk

an D

igita

l5-

24Te

rmin

al x

46/9

Mas

ukan

Dig

ital

5-25

Term

inal

x46

/11

Mas

ukan

Dig

ital

5-26

Term

inal

x46

/13

Mas

ukan

Dig

ital

5-3*

Dig

ital O

utpu

t5-

30Te

rmin

al 2

7 di

gita

l out

put

5-31

Term

inal

29

Dig

ital o

utpu

t5-

32Te

rm X

30/6

Dig

i Out

(MCB

101

)5-

33Te

rm X

30/7

Dig

i Out

(MCB

101

)5-

4*Re

lai

5-40

Rela

i Fun

gsi

5-41

Penu

ndaa

n O

n (H

idup

), Re

lai

5-42

Penu

ndaa

n Off

(mat

i), R

elai

5-5*

Inpu

t Pu

lsa

5-50

Term

. 29

Frek

uens

i Ren

dah

5-51

Term

. 29

Frek

uens

i Tin

ggi

5-52

Term

. 29

Ref

Rend

ah/N

ilai U

mp-

balik

5-53

Term

. 29

Ref

Ting

gi/N

ilai U

mp-

balik

5-54

Teta

pan

Wak

tu F

ilter

Pul

sa #

295-

55Te

rm. 3

3 Fr

ekue

nsi R

enda

h5-

56Te

rm. 3

3 Fr

ekue

nsi T

ingg

i5-

57Te

rm. 3

3 Re

f Re

ndah

/Nila

i Um

p-ba

lik5-

58Te

rm. 3

3 Re

f Ti

nggi

/Nila

i Um

p-ba

lik5-

59Te

tapa

n W

aktu

Filt

er P

ulsa

#33

5-6*

Out

put

Puls

a5-

60Va

riabe

l Out

put

Puls

a Te

rmin

al 2

75-

62Fr

ek. M

aks.

Kel

uara

n P

ulsa

#27

5-63

Varia

bel O

utpu

t Pu

lsa

Term

inal

29

5-65

Frek

. Mak

s. K

elua

ran

Pul

sa #

295-

66Va

r. O

utpu

t Pu

lsa

Di T

erm

. X30

/65-

68Fr

ek. M

aks.

Kel

uara

n P

ulsa

#X3

0/6

5-7*

Inpu

t En

code

r 24

V5-

70Pu

lsa

Term

32/

33 p

er P

utar

an5-

71Te

rm 3

2/33

Ara

h e

ncod

er5-

72Te

rm 3

2/33

Enc

oder

Typ

e5-

8*I/O

Opt

ions

5-80

AH

F Ca

p R

econ

nect

Del

ay5-

9*Bu

s Te

rkon

trol

5-90

Kont

rol B

us R

elai

& D

igita

l5-

93Ko

ntro

l Bus

Pul

sa K

elua

r #2

75-

94Pr

a-Se

tel T

imeo

ut P

ulsa

Kel

uar

#27

5-95

Kont

rol B

us P

ulsa

Kel

uar

#29

5-96

Pra-

Sete

l Tim

eout

Pul

sa K

elua

r #2

95-

97O

utpu

t Pu

lsa

#X30

/6 K

ontr

ol B

us5-

98O

utpu

t Pu

lsa

#X30

/6 P

rese

t Ti

meo

ut6-

**A

nalo

g In

/Out

6-0*

Mod

e I/O

Ana

log

6-00

Wak

tu Is

tirah

at A

rus/

Teg.

t'la

lu rd

h6-

01Fu

ngsi

Istir

ahat

aru

s/te

g. t

'lalu

rdh

6-1*

Inpu

t A

nalo

g 1

6-10

Term

inal

53

Tega

ngan

Ren

dah

6-11

Term

inal

53

Tega

ngan

Tin

ggi

6-12

Term

inal

53

Aru

s Re

ndah

6-13

Term

inal

54

Aru

s Ti

nggi

6-14

Term

inal

53

Ref

Rdh/

Nila

i Um

p-Ba

lik6-

15Te

rmin

al 5

3 Re

f Ti

nggi

/Nila

i Um

p-Ba

lik6-

16Te

tapa

n W

aktu

Filt

er T

erm

inal

53

6-2*

Inpu

t A

nalo

g 2

6-20

Term

inal

54

Tega

ngan

Ren

dah

6-21

Term

inal

54

Tega

ngan

Tin

ggi

6-22

Term

inal

54

Aru

s Re

ndah

6-23

Term

inal

54

Aru

s Ti

nggi

6-24

Term

inal

54

Ref

Rdh/

Nila

i Um

p-Ba

lik6-

25Te

rmin

al 5

4 Re

f Ti

nggi

/Nila

i Um

p-Ba

lik6-

26Te

rmin

al 5

4 Te

tapa

n W

aktu

Filt

er6-

3*In

put

Ana

log

36-

30Te

rmin

al X

30/1

1 Te

gang

an R

enda

h6-

31Te

rmin

al X

30/1

1 Te

gang

an T

ingg

i6-

34Te

rm. X

30/1

1 N

il.Re

f/U

mp.

Blk.

Rd.

6-35

Term

. X30

/11

Nil.

Ref/

Um

p.Bl

k. T

g.6-

36Te

tapa

n W

aktu

Filt

er T

erm

inal

X30

/11

6-4*

Inpu

t A

nalo

g 4

6-40

Term

inal

X30

/12

Tega

ngan

Ren

dah

6-41

Term

inal

X30

/12

Tega

ngan

Tin

ggi

6-44

Term

. X30

/12

Nil.

Ref/

Um

p.Bl

k. R

d.6-

45Te

rm. X

30/1

2 N

il.Re

f/U

mp.

Blk.

Tg.

6-46

Teta

pan

Wak

tu F

ilter

Ter

min

al X

30/1

26-

5*O

utpu

t A

nalo

g 1

6-50

Term

inal

42

Out

put

6-51

Term

inal

42

Skal

a O

utpu

t M

in.

6-52

Term

inal

42

Skal

a O

utpu

t M

aks.

6-53

Kont

rol B

us K

elua

ran

Ter

min

al 4

26-

54Pr

a-Se

tel T

ime-

Out

Klu

aran

Ter

m. 4

26-

55Te

rmin

al 4

2 Ke

luar

an F

ilter

6-6*

Kelu

aran

Ana

log

26-

60Ke

luar

an T

erm

inal

X30

/8

6-61

Skal

a M

in. T

erm

inal

X30

/86-

62Sk

ala

Mak

s. T

erm

inal

X30

/86-

63Te

rmin

al x

30/8

Kon

trol

Bus

6-64

Term

inal

x30

/8 P

rese

t Ti

meo

ut6-

7*A

nalo

g o

utpu

t 3

6-70

Term

inal

x45

/1 K

elua

ran

6-71

Term

inal

x45

/1 M

in. S

kala

6-72

Term

inal

x45

/1 M

aks.

Ska

la6-

73Te

rmin

al x

45/1

Kon

trol

Bus

6-74

T'm

x45

/1 P

'set

Tim

eout

Kel

uar

6-8*

Kelu

aran

Ana

log

46-

80te

rmin

al x

45/3

Kel

uara

n6-

81Te

rmin

al x

45/3

Min

. Ska

la6-

82Te

rmin

al x

45/3

Mak

s. S

kala

6-83

Term

inal

x45

/3 K

ontr

ol B

us6-

84T'

m x

45/3

P'se

t Ti

meo

ut K

elua

r7-

**Pe

ngon

trol

7-0*

Ktrl

PID

Kec

epat

an7-

00PI

D K

ecep

atan

Sum

ber

Um

pan

Bal

ik7-

01Sp

eed

PID

Dro

op7-

02Pe

ngua

tan

Pro

pors

iona

l PID

Kec

epat

an7-

03W

aktu

Inte

gral

PID

Kec

epat

an7-

04W

aktu

Per

beda

an P

ID K

ecep

atan

7-05

Btsa

n. P

engu

atan

P'b

edaa

n P

ID K

cptn

.7-

06W

aktu

Filt

er L

owpa

ss P

ID K

ecep

atan

7-07

Perb

andi

ngan

Gig

i Um

p B

lk P

ID u

tkkc

ptn

7-08

PID

Kec

epat

an F

akto

r Te

rusk

an U

mpa

n7-

09Sp

eed

PID

Err

or C

orre

ctio

n w

/ Ra

mp

7-1*

Ktrl.

PI

tors

i7-

10To

rque

PI F

eedb

ack

Sour

ce7-

12Pe

ngua

tan

Pro

pors

iona

l PI T

orsi

7-13

Wak

tu In

tegr

asi P

I Tor

si7-

16To

rque

PI L

owpa

ss F

ilter

Tim

e7-

18To

rque

PI F

eed

For

war

d F

acto

r7-

19Cu

rren

t Co

ntro

ller

Rise

Tim

e7-

2*Kn

tr. P

r. U

mp.

Blk

7-20

CL P

rose

s Su

mbe

r U

mpa

n B

alik

17-

22CL

Pro

ses

Sum

ber

Um

pan

Bal

ik 2

7-3*

Kont

rol P

rose

s PI

D7-

30PI

D K

ontr

ol N

orm

al/T

erba

lik7-

31PI

D P

rose

s A

nti T

ergu

lung

7-32

PID

Kon

trol

Kec

epat

an A

wal

7-33

PID

Pro

ses

Peng

uata

n P

ropo

rsio

nal

7-34

PID

Pro

ses

Wak

tu In

tegr

al7-

35PI

D P

rose

s W

aktu

Per

beda

an7-

36PI

D P

rose

s Ba

tas

Peng

uata

n P

erbe

daan

7-38

PID

Pro

ses

Fakt

or T

erus

kan

Um

pan

7-39

Leba

r Pi

ta R

efer

ensi

On

7-9*

Posi

tion

PI

Ctrl.

7-90

Posi

tion

PI F

eedb

ack

Sour

ce7-

91Po

sitio

n P

I Dro

op7-

92Po

sitio

n P

I Pro

port

iona

l Gai

n7-

93Po

sitio

n P

I Int

egra

l Tim

e7-

94Po

sitio

n P

I Fee

dbac

k Sc

ale

Num

erat

or7-

95Po

sitio

n P

I Fee

bbac

k Sc

ale

Den

omin

ator

7-97

Posi

tion

PI M

axim

um S

peed

Abo

veM

aste

r

7-98

Posi

tion

PI F

eed

For

war

d F

acto

r7-

99Po

sitio

n P

I Min

imum

Ram

p T

ime

8-**

Kom

. dan

Pili

han

8-0*

Peng

atur

an U

mum

8-01

Bagi

an K

ontr

ol8-

02Su

mbe

r Ka

ta K

ontr

ol8-

03W

aktu

Istir

ahat

Kat

a Ko

ntro

l8-

04Fu

ngsi

Istir

ahat

Kat

a Ko

ntro

l8-

05Fu

ngsi

Akh

ir d

ari I

stira

hat

8-06

Rese

t Is

tirah

at K

ata

Kont

rol

8-07

Pem

icu

Dia

gnos

a8-

08Pe

mba

caan

Pen

yarin

gan

8-1*

Kntr

l P'a

tur.

Kata

8-10

Profi

l Kat

a Ko

ntro

l8-

13Ka

ta S

tatu

s ST

W D

apat

Dikon

figurasi

8-14

Kata

Kon

trol

CTW

dikon

figurasi

8-17

Confi

gurable

Ala

rm a

nd W

arni

ngw

ord

8-19

Prod

uct

Code

8-3*

P'at

uran

t'm

inal

8-30

Prot

okol

8-31

Ala

mat

8-32

Baud

Rat

e Po

rt F

C8-

33Pa

ritas

/ B

it S

top

8-34

Estim

asi s

iklu

s w

aktu

8-35

Penu

ndaa

n t

angg

apan

Min

imum

8-36

Penu

ndaa

n T

angg

apan

Mak

s8-

37Pe

nund

aan

Inte

r-Ch

ar M

aks

8-4*

Set

prot

okol

MC

FC

8-40

Pem

iliha

n t

eleg

ram

8-41

Para

met

ers

for

Sign

als

8-42

PCD

Men

ulis

kon

figurasi

8-43

PCD

Mem

baca

kon

figurasi

8-5*

Dig

ital/B

us8-

50Pe

mili

han

Coa

stin

g8-

51Pe

mili

han

sto

p c

epat

8-52

Pilih

an B

rake

DC

8-53

pem

iliha

n s

tart

8-54

Pem

balik

an T

erpi

lih8-

55Pe

ngat

uran

Ter

pilih

8-56

Pem

iliha

n r

efer

ensi

pre

set

8-57

Profi

drive

OFF

2 Se

lect

8-58

Profi

drive

OFF

3 Se

lect

8-8*

Dia

gnos

tik P

ort

FC8-

80Ju

mla

h P

esan

Bus

8-81

Jum

lah

Kes

alah

an B

us8-

82Ju

mla

h P

esan

Sla

ve8-

83Ju

mla

h K

esal

ahan

Sla

ve8-

9*Bu

s Jo

g8-

90Ke

cepa

tan

Bus

Jog

18-

91Ke

cepa

tan

Bus

Jog

29-

**PR

OFI

driv

e9-

00Se

tpoi

nt9-

07Ac

tual

Val

ue9-

15PC

D W

rite Co

nfigu

ratio

n9-

16PC

D R

ead

Con

figuration

9-18

Nod

e Ad

dres

s9-

19D

rive

Uni

t Sy

stem

Num

ber

9-22

Tele

gram

Sel

ectio

n9-

23Pa

ram

eter

s fo

r Si

gnal

s

9-27

Para

met

er E

dit

9-28

Proc

ess

Cont

rol

9-44

Faul

t M

essa

ge C

ount

er9-

45Fa

ult

Code

9-47

Faul

t N

umbe

r9-

52Fa

ult

Situ

atio

n C

ount

er9-

53Profi

bus

War

ning

Wor

d9-

63Ac

tual

Bau

d R

ate

9-64

Dev

ice Iden

tificatio

n9-

65Profi

le N

umbe

r9-

67Co

ntro

l Wor

d 1

9-68

Stat

us W

ord

19-

70Ed

it S

et-u

p9-

71Profi

bus

Save

Dat

a Va

lues

9-72

Profi

busD

riveR

eset

9-75

DO

Iden

tificatio

n9-

80Defi

ned

Par

amet

ers

(1)

9-81

Defi

ned

Par

amet

ers

(2)

9-82

Defi

ned

Par

amet

ers

(3)

9-83

Defi

ned

Par

amet

ers

(4)

9-84

Defi

ned

Par

amet

ers

(5)

9-85

Defi

ned

Par

amet

ers

(6)

9-90

Chan

ged

Par

amet

ers

(1)

9-91

Chan

ged

Par

amet

ers

(2)

9-92

Chan

ged

Par

amet

ers

(3)

9-93

Chan

ged

Par

amet

ers

(4)

9-94

Chan

ged

Par

amet

ers

(5)

9-99

Profi

bus

Revi

sion

Cou

nter

10-*

*Fi

eldb

us C

AN

10-0

*P'

atur

an B

'sam

a10

-00

Prot

okol

CA

N10

-01

Pem

iliha

n B

aud

Rat

e10

-02

MAC

ID10

-05

P'ht

g. K

esal

ahan

Pen

girim

an P

'bac

a10

-06

P'ht

g. K

esal

ahan

Pen

erim

aan

P'b

aca

10-0

7Pe

mba

caan

pen

ghitu

ngan

Bus

Off

10-1

*D

evic

eNet

10-1

0Pe

mili

han

Jen

is D

ata

Pros

es10

-11

Tulis

Kon

fig D

ata

Pros

es10

-12

Baca

Kon

fig D

ata

Pros

es10

-13

Para

met

er P

erin

gata

n10

-14

Refe

rens

i jar

inga

n10

-15

Kont

rol J

arin

gan

10-2

*Fi

lter

COS

10-2

0CO

S Fi

lter

110

-21

COS

Filte

r 2

10-2

2CO

S Fi

lter

310

-23

COS

Filte

r 4

10-3

*A

kses

Par

amet

er10

-30

Inde

ks U

rut

10-3

1Pe

nyim

pana

n N

ilai D

ata

10-3

2Re

visi

Dev

icen

et10

-33

Sela

lu S

impa

n10

-34

Kode

Pro

duk

Dev

iceN

et10

-39

Para

met

er D

evic

enet

F10

-5*

CAN

terb

uka

10-5

0Tu

lis Kon

fig D

ata

Pros

es10

-51

Baca

Kon

fig D

ata

Pros

es

Apendiks VLT® AutomationDrive FC 301/302

70 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

99

Page 73: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

12-*

*Et

hern

et12

-0*

P'at

uran

IP12

-00

Tuga

s A

lam

at IP

12-0

1A

lam

at IP

12-0

2La

pisa

n J

arin

gan

12-0

3G

atew

ay D

efau

lt12

-04

Serv

er D

HCP

12-0

5Ko

ntra

k Ka

dalu

arsa

12-0

6N

ama

Serv

er12

-07

Nam

a D

omai

n12

-08

Nam

a H

ost

12-0

9A

lam

at F

isik

12-1

*Pa

ram

eter

Lin

k Et

h12

-10

Stat

us L

ink

12-1

1D

uras

i Lin

k12

-12

Neg

osia

si O

tom

atis

12-1

3Kc

ptan

. Lin

k12

-14

Dup

lex

Link

12-2

*D

ata

Pros

es12

-20

Hal

Kon

trol

12-2

1Tu

lis Kon

fig D

ata

Pros

es12

-22

Baca

Kon

fig D

ata

Pros

es12

-23

Proc

ess

Dat

a Co

nfig

Writ

e Si

ze12

-24

Proc

ess

Dat

a Co

nfig

Rea

d S

ize

12-2

7M

aste

r Ad

dres

s12

-28

Peny

impa

nan

Nila

i Dat

a12

-29

Sela

lu S

impa

n12

-3*

Ethe

rNet

/IP12

-30

Para

met

er P

erin

gata

n12

-31

Refe

rens

i jar

inga

n12

-32

Kont

rol J

arin

gan

12-3

3Re

visi

CIP

12-3

4Ko

de P

rodu

k CI

P12

-35

Para

met

er E

DS

12-3

7Pe

ngur

anga

n T

imer

CO

S12

-38

Filte

r CO

S12

-4*

Mod

bus

TCP

12-4

0St

atus

Par

amet

er12

-41

Slav

e M

essa

ge C

ount

12-4

2Sl

ave

Exce

ptio

n M

essa

ge C

ount

12-5

*Et

herC

AT12

-50

Confi

gured

Sta

tion

Alia

s12

-51

Confi

gured

Sta

tion

Add

ress

12-5

9Et

herC

AT S

tatu

s12

-6*

Ethe

rnet

Pow

erLi

nk12

-60

Nod

e ID

12-6

2SD

O T

imeo

ut12

-63

Basi

c Et

hern

et T

imeo

ut12

-66

Thre

shol

d12

-67

Thre

shol

d C

ount

ers

12-6

8Cu

mul

ativ

e Co

unte

rs12

-69

Ethe

rnet

Pow

erLi

nk S

tatu

s12

-8*

Lay

Ethe

rnet

Lai

n12

-80

Serv

er F

TP12

-81

Serv

er H

TTP

12-8

2La

yana

n S

MTP

12-8

9Po

rt S

alur

an S

oket

tra

nspa

ran

12-9

*La

y Et

hern

et L

anju

t12

-90

Dia

gnos

a ka

bel

12-9

1Au

to C

ross

Ove

r12

-92

Men

cari

IGM

P12

-93

Panj

ang

Kab

el S

alah

12-9

4Pr

otek

si B

adai

Pem

anca

r12

-95

Filte

r Ba

dai P

eman

car

12-9

6Po

rt Con

fig12

-98

Inte

rfac

e Pe

nghi

tung

12-9

9Pe

nghi

tung

Med

ia13

-**

Logi

ka C

erda

s13

-0*

Peng

atur

an S

LC13

-00

Mod

e Pe

ngon

trol

SL

13-0

1St

art

Peris

tiwa

13-0

2H

entik

an P

eris

tiwa

13-0

3Re

set

SLC

13-1

*Pe

mba

ndin

g13

-10

Suku

Ope

rasi

Pem

band

ing

13-1

1O

pera

tor

Pem

band

ing

13-1

2N

ilai P

emba

ndin

g13

-1*

RS F

lip F

lops

13-1

5RS

-FF

Ope

rand

S13

-16

RS-F

F O

pera

nd R

13-2

*Ti

mer

s13

-20

Tim

er P

engo

ntro

l SL

13-4

*Pe

ratu

ran

Log

ika

13-4

0A

tura

n L

ogik

a Bo

olea

n 1

13-4

1O

pera

tor

Atu

ran

Log

ika

113

-42

Atu

ran

Log

ika

Bool

ean

213

-43

Ope

rato

r A

tura

n L

ogik

a 2

13-4

4A

tura

n L

ogik

a Bo

olea

n 3

13-5

*Ke

adaa

n13

-51

Peris

tiwa

Peng

ontr

ol S

L13

-52

Tind

akan

Pen

gont

rol S

L14

-**

Fung

si K

husu

s14

-0*

Switc

hing

Pem

balik

14-0

0Po

la s

witc

hing

14-0

1Fr

ekue

nsi s

witc

hing

14-0

3Ke

lebi

han

mod

ulas

i14

-04

PWM

Aca

k14

-06

Dea

d T

ime

Com

pens

atio

n14

-1*

Sum

tg

ny'

l./pd

m14

-10

Kega

gala

n d

i Sum

ber

14-1

1Te

g. d

i Sm

b. p

d S

mb.

Kru

sak.

14-1

2Fu

ngsi

pd

Ket

idak

-sei

mba

ngan

Sum

b.14

-14

Kin.

Bac

kup

Tim

e O

ut14

-15

Kin.

Bac

kup

Trip

Rec

over

y Le

vel

14-1

6Ki

n. B

acku

p G

ain

14-2

*Re

set

Trip

14-2

0M

ode

Rese

t14

-21

Wak

tu R

esta

rt O

tom

atis

14-2

2M

odus

Ope

rasi

14-2

3Pe

ngat

uran

Jen

is K

ode

14-2

4Pe

nund

aan

Trip

pad

a Ba

tas

Aru

s14

-25

Penu

ndaa

n T

rip p

ada

Bata

san

Tor

si14

-26

Pnun

da.T

rip p

d K

rusa

k Pm

blk.

14-2

8Pe

ngat

uran

Pro

duks

i14

-29

Kode

laya

nan

14-3

*Kt

rl b

atas

aru

s.14

-30

Ktrl.

Bts

. Aru

s, P

'ngu

atan

Pro

p14

-31

Kont

rol B

atas

Aru

s, W

aktu

Inte

gras

i

14-3

2Ko

ntro

l Bat

as A

rus,

Wak

tu F

ilter

14-3

5Te

mpa

t Pe

rlind

unga

n14

-36

Fiel

dwea

keni

ng F

unct

ion

14-4

*O

ptim

asi E

nerg

i14

-40

Ting

kat

VT14

-41

Mag

netis

asi M

inim

um A

EO14

-42

Frek

uens

i Min

imum

AEO

14-4

3Co

sphi

Mot

or14

-5*

Ling

kung

an14

-50

Filte

r RF

I14

-51

Kom

pens

asi D

C L

ink

14-5

2Ko

ntro

l Kip

as14

-53

Mon

itor

Kipa

s14

-55

Filte

r Ke

luar

an14

-56

Filte

r Ke

luar

an K

apas

itans

i14

-57

Filte

r Ke

luar

an In

dukt

ansi

14-5

9Ju

mla

h A

ktua

l dar

i Uni

t In

vert

er14

-7*

Keco

coka

n14

-72

Kata

Ala

rm V

LT14

-73

Kata

Per

inga

tan

VLT

14-7

4VL

T Pe

rpan

jang

an K

ata

Stat

us14

-8*

Ops

i14

-80

Ops

i Di b

erik

an o

leh

24V

DC

Eks

tern

al14

-88

Opt

ion

Dat

a St

orag

e14

-89

Opt

ion

Det

ectio

n14

-9*

Peng

atur

an S

alah

14-9

0Ti

ngka

t ke

rusa

kan

15-*

*In

fo. F

rek.

Kon

vrt

15-0

*D

ata

Ope

rasi

15-0

0Ja

m P

engo

pera

sian

15-0

1Ja

m P

utar

an15

-02

Peng

hitu

ng k

Wh

15-0

3Pe

nyal

aan

15-0

4Ke

lebi

han

Suh

u15

-05

Kele

b. T

egan

gan

15-0

6Re

set

peng

hitu

ng k

Wh

15-0

7Pe

nghi

tung

Res

et J

am P

utar

an15

-1*

Peng

at. L

og D

ata

15-1

0Su

mbe

r lo

g15

-11

Inte

rval

Log

ging

15-1

2Pe

ristiw

a Pe

mic

u15

-13

Mod

e Lo

ggin

g15

-14

Sam

pel S

ebel

um P

emic

u15

-2*

Log

his

tori

s15

-20

Log

his

toris

: Per

istiw

a15

-21

Log

His

toris

: Nila

i15

-22

Log

his

toris

: Wak

tu15

-3*

Log

ker

usak

an15

-30

Log

Ker

usak

an: K

ode

Kesa

laha

n15

-31

Log

Ker

usak

an: N

ilai

15-3

2Lo

g K

erus

akan

: Wak

tu15

-4*

Iden

t. F

rek.

Kon

v.15

-40

Jeni

s FC

15-4

1Ba

gian

Day

a15

-42

Tega

ngan

15-4

3Ve

rsi P

eran

gkat

Lun

ak15

-44

Unt

aian

Jen

is K

ode

Teru

rut

15-4

5U

ntai

an J

enis

kod

e A

ktua

l15

-46

No

Ord

er K

onve

rter

Fre

kuen

si

15-4

7N

o o

rder

kar

tu d

aya

15-4

8N

o ID

LCP

15-4

9Ka

rtu

Kon

trol

ID S

W15

-50

Kart

u D

aya

ID S

W15

-51

Nom

or S

eria

l Kon

vert

er F

reku

ensi

15-5

3N

o s

eria

l kar

tu d

aya

15-5

8Sm

art

Setu

p F

ilena

me

15-5

9CS

IV N

ama

File

15-6

*Id

ent

Pilih

an15

-60

Pilih

an T

eran

gkai

15-6

1Ve

rsi S

W P

iliha

n15

-62

Nom

or P

iliha

n P

esan

an15

-63

Nom

or S

eri P

iliha

n15

-70

Pilih

an d

i Slo

t A

15-7

1Ve

rsi S

W P

iliha

n S

lot

A15

-72

Pilih

an d

i Slo

t B

15-7

3Ve

rsi S

W P

iliha

n S

lot

B15

-74

Pilih

an p

ada

Slot

C0

15-7

5Sw

Ver

sion

Ops

i di S

lot

C015

-76

Pilih

an p

ada

Slot

C1

15-7

7Sw

Ver

sion

Ops

i di S

lot

C115

-8*

Ope

ratin

g D

ata

II15

-80

Fan

Run

ning

Hou

rs15

-81

Pres

et F

an R

unni

ng H

ours

15-8

9Co

nfigu

ratio

n C

hang

e Co

unte

r15

-9*

Info

Par

amet

er15

-92

Para

met

er terde

finisi

15-9

3Pa

ram

ater

Mod

ifikasi

15-9

8Iden

tifikasi

Driv

e15

-99

Met

adat

a Pa

ram

eter

16-*

*Pe

mba

caan

Dat

a16

-0*

Stat

us U

mum

16-0

0Ka

ta K

ontr

ol16

-01

Refe

rens

i [U

nit]

16-0

2Re

fere

nsi %

16-0

3Ka

ta S

tatu

s16

-05

Nila

i Akt

ual U

tam

a [%

]16

-06

Actu

al P

ositi

on16

-07

Targ

et P

ositi

on16

-08

Posi

tion

Err

or16

-09

Pem

baca

an c

usto

m16

-1*

Stat

us M

otor

16-1

0D

aya

[kW

]16

-11

Day

a [h

p]16

-12

Tega

ngan

Mot

or16

-13

Frek

uens

i16

-14

Aru

s M

otor

16-1

5Fr

ekue

nsi [

%]

16-1

6To

rsi [

Nm

]16

-17

Kece

pata

n [R

PM]

16-1

8Te

rmal

Mot

or16

-19

Suhu

sen

sor

KTY

16-2

0Su

dut

Mot

or16

-21

Torq

ue [%

] H

igh

Res

.16

-22

Tors

i [%

]16

-23

Mot

or S

haft

Pow

er [k

W]

16-2

4Ca

libra

ted

Sta

tor

Resi

stan

ce16

-25

Tors

i [N

m]

Ting

gi16

-3*

Stat

us F

rek.

kon

v.

16-3

0Te

gang

an D

C li

nk16

-32

Ener

gi B

rake

/ d

et.

16-3

3En

ergi

Bra

ke /

2 m

nt.

16-3

4Su

hu H

eats

ink

16-3

5Te

rmal

Pem

balik

16-3

6A

rus

Nom

inal

Inve

rter

16-3

7A

rus

Mak

s. In

vert

er16

-38

Kond

isi P

engo

ntro

l SL

16-3

9Su

hu K

artu

Kon

trol

16-4

0Pe

nyan

gga

Logg

ing

Tel

ah P

enuh

16-4

1St

atus

line

Das

ar L

CP16

-44

Spee

d E

rror

[RPM

]16

-45

Mot

or P

hase

U C

urre

nt16

-46

Mot

or P

hase

V C

urre

nt16

-47

Mot

or P

hase

W C

urre

nt16

-48

Spee

d R

ef. A

fter

Ram

p [R

PM]

16-4

9A

rus

Sum

ber

Mas

alah

16-5

*Re

f &

Um

p-ba

lik16

-50

Refe

rens

i Eks

tern

al16

-51

Refe

rens

i Pul

sa16

-52

Um

pan

Bal

ik [U

nit]

16-5

3Re

fere

nsi D

igi P

ot16

-57

Feed

back

[RPM

]16

-6*

Inpu

t &

Out

put

16-6

0In

put

Dig

ital

16-6

1Te

rmin

al 5

3 Pe

gatu

ran

sw

itch

16-6

2In

put

Ana

log

53

16-6

3Te

rmin

al 5

4 pe

ngat

uran

sw

itch

16-6

4In

put

Ana

log

54

16-6

5O

utpu

t A

nalo

g 4

2 [m

A]

16-6

6O

utpu

t D

igita

l [bi

n]16

-67

Frek

. Inp

ut #

29 [H

z]16

-68

Frek

. Inp

ut #

33 [H

z]16

-69

Out

put

Puls

a #2

7 [H

z]16

-70

Out

put

Puls

a #2

9 [H

z]16

-71

Out

put

Rela

i [bi

n]16

-72

Peng

hitu

ng A

16-7

3Pe

nghi

tung

B16

-75

Mas

uk A

nalo

g X

30/1

116

-76

Mas

uk A

nalo

g X

30/1

216

-77

Kelu

ar A

nalo

g X

30/8

[mA

]16

-78

Kelu

aran

Ana

log

X45

/1 [m

A]

16-7

9Ke

luar

an A

nalo

g X

45/3

[mA

]16

-8*

Fiel

dbus

& P

ort

FC16

-80

Fiel

dbus

CTW

116

-82

Fiel

dbus

REF

116

-83

Fiel

dbus

REF

216

-84

Kom

. Pili

han

STW

16-8

5Po

rt F

C C

TW 1

16-8

6Po

rt F

C R

EF 1

16-8

7Bu

s Re

adou

t A

larm

/War

ning

16-8

9Co

nfigu

rable

Ala

rm/W

arni

ng W

ord

16-9

*P'

baca

an D

iagn

osa

16-9

0Ka

ta A

larm

16-9

1A

larm

wor

d 2

16-9

2Ka

ta P

erin

gata

n16

-93

Kata

Per

inga

tan

216

-94

Ekst

. Kat

a St

atus

Apendiks Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 71

9 9

Page 74: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

17-*

*O

psi u

mpa

n b

alik

17-1

*Tm

s. in

t'fac

e en

c.17

-10

Jeni

s Si

nyal

17-1

1Re

solu

si (P

PR)

17-2

*In

t'fac

e En

c. A

bs.

17-2

0Pe

mili

han

Pro

toko

l17

-21

Reso

lusi

(Pul

sa/P

utar

an)

17-2

2M

ultit

urn

Rev

olut

ions

17-2

4Pa

njan

g D

ata

SSI

17-2

5Ke

cepa

tan

Clo

ck17

-26

Form

at D

ata

SSI

17-3

4Ke

cepa

tan

Bau

d H

IPER

FACE

17-5

*In

terf

ace

Reso

lver

17-5

0Ku

tub

17-5

1Vo

ltase

Mas

ukan

17-5

2Fr

ekue

nsi M

asuk

an17

-53

Rasi

o T

rans

form

asi

17-5

6En

code

r Si

m. R

esol

utio

n17

-59

Reso

lver

Inte

rfac

e17

-6*

Pant

au &

Apl

ikas

i17

-60

Ara

h U

mpa

n B

alik

17-6

1M

onito

r Si

nyal

Um

pan

Bal

ik17

-7*

Posi

tion

Sca

ling

17-7

0Po

sitio

n U

nit

17-7

1Po

sitio

n U

nit

Scal

e17

-72

Posi

tion

Uni

t N

umer

ator

17-7

3Po

sitio

n U

nit

Den

omin

ator

17-7

4Po

sitio

n Offset

17-7

5Po

sitio

n R

ecov

ery

at P

ower

-up

17-7

6Po

sitio

n A

xis

Mod

e17

-77

Posi

tion

Fee

dbac

k M

ode

17-8

*Po

sitio

n H

omin

g17

-80

Hom

ing

Fun

ctio

n17

-81

Hom

e Sy

nc F

unct

ion

17-8

2H

ome

Posi

tion

17-8

3H

omin

g S

peed

17-8

4H

omin

g T

orqu

e Li

mit

17-8

5H

omin

g T

imou

t17

-9*

Posi

tion

Con

fig17

-90

Abs

olut

e Po

sitio

n M

ode

17-9

1Re

lativ

e Po

sitio

n M

ode

17-9

2Po

sitio

n C

ontr

ol S

elec

tion

17-9

3M

aste

r Offset

Sel

ectio

n17

-94

Rota

ry A

bsol

ute

Dire

ctio

n18

-**

Baca

an D

ata

218

-3*

Ana

log

Rea

dout

s18

-36

Mas

ukan

ana

log

X48

/2 [m

A]

18-3

7M

asuk

an S

uhu

X48

/418

-38

Mas

ukan

Suh

u X

48/7

18-3

9M

asuk

an S

uhu

X48

/10

18-5

*A

ctiv

e A

larm

s/W

arni

ngs

18-5

5Ac

tive

Ala

rm N

umbe

rs18

-56

Activ

e W

arni

ng N

umbe

rs18

-6*

Inpu

ts &

Out

puts

218

-60

Dig

ital I

nput

230

-**

Fitu

r Kh

usus

30-2

*A

dv. S

tart

Adj

ust

30-2

0H

igh

Sta

rtin

g T

orqu

e Ti

me

[s]

30-2

1H

igh

Sta

rtin

g T

orqu

e Cu

rren

t [%

]

30-2

2Lo

cked

Rot

or P

rote

ctio

n30

-23

Lock

ed R

otor

Det

ectio

n T

ime

[s]

30-2

4Lo

cked

Rot

or D

etec

tion

Spe

ed E

rror

[%]

30-8

*Ke

coco

kan

(I)

30-8

0In

dukt

ansi

sum

bu-d

(Ld)

30-8

1Ta

hana

n R

em (o

hm)

30-8

3Pe

ngua

tan

Pro

p P

ID u

tk k

cptn

30-8

4PI

D P

rose

s Pe

ngua

tan

Pro

pors

iona

l31

-**

Ops

i Byp

ass

31-0

0By

pass

Mod

e31

-01

Bypa

ss S

tart

Tim

e D

elay

31-0

2By

pass

Trip

Tim

e D

elay

31-0

3Te

st M

ode

Activ

atio

n31

-10

Bypa

ss S

tatu

s W

ord

31-1

1By

pass

Run

ning

Hou

rs31

-19

Rem

ote

Bypa

ss A

ctiv

atio

n35

-**

Sens

or In

put

Opt

ion

35-0

*Te

mp.

Inpu

t M

ode

35-0

0Te

rm. X

48/4

Tem

pera

ture

Uni

t35

-01

Term

. X48

/4 T

ipe

Inpu

t35

-02

Term

. X48

/7 T

empe

ratu

re U

nit

35-0

3Te

rm. X

48/7

Tip

e In

put

35-0

4Te

rm. X

48/1

0 Te

mpe

ratu

re U

nit

35-0

5Te

rm. X

48/1

0 Ti

pe In

put

35-0

6Fu

ngsi

Per

inga

tan

Sen

sor

Suhu

35-1

*Te

mp.

Inpu

t X4

8/4

35-1

4Te

rm. X

48/4

Filt

er T

ime

Cons

tant

35-1

5Te

rm. X

48/4

Tem

p. M

onito

r35

-16

Term

. X48

/4 L

ow T

emp.

Lim

it35

-17

Term

. X48

/4 H

igh

Tem

p. L

imit

35-2

*Te

mp.

Inpu

t X4

8/7

35-2

4Te

rm. X

48/7

Filt

er T

ime

Cons

tant

35-2

5Te

rm. X

48/7

Tem

p. M

onito

r35

-26

Term

. X48

/7 L

ow T

emp.

Lim

it35

-27

Term

. X48

/7 H

igh

Tem

p. L

imit

35-3

*Te

mp.

Inpu

t X4

8/10

35-3

4Te

rm. X

48/1

0 Fi

lter

Tim

e Co

nsta

nt35

-35

Term

. X48

/10

Tem

p. M

onito

r35

-36

Term

. X48

/10

Low

Tem

p. L

imit

35-3

7Te

rm. X

48/1

0 H

igh

Tem

p. L

imit

35-4

*A

nalo

g In

put

X48/

235

-42

Term

. X48

/2 A

rus

Rend

ah35

-43

Term

. X48

/2 H

igh

Cur

rent

35-4

4Te

rm. X

48/2

Low

Ref

./Fee

db. V

alue

35-4

5Te

rm. X

48/2

Hig

h R

ef./F

eedb

. Val

ue35

-46

Term

. X48

/2 F

ilter

Tim

e Co

nsta

nt42

-**

Safe

ty F

unct

ions

42-1

*Sp

eed

Mon

itori

ng42

-10

Mea

sure

d S

peed

Sou

rce

42-1

1En

code

r Re

solu

tion

42-1

2En

code

r D

irect

ion

42-1

3G

ear

Ratio

42-1

4Fe

edba

ck T

ype

42-1

5Fe

edba

ck F

ilter

42-1

7To

lera

nce

Erro

r42

-18

Zero

Spe

ed T

imer

42-1

9Ze

ro S

peed

Lim

it42

-2*

Safe

Inpu

t

42-2

0Sa

fe F

unct

ion

42-2

1Ty

pe42

-22

Dis

crep

ancy

Tim

e42

-23

Stab

le S

igna

l Tim

e42

-24

Rest

art

Beha

viou

r42

-3*

Gen

eral

42-3

0Ex

tern

al F

ailu

re R

eact

ion

42-3

1Re

set

Sour

ce42

-33

Para

met

er S

et N

ame

42-3

5S-

CRC

Val

ue42

-36

Leve

l 1 P

assw

ord

42-4

*SS

142

-40

Type

42-4

1Ra

mp

Profile

42-4

2D

elay

Tim

e42

-43

Del

ta T

42-4

4D

ecel

erat

ion

Rat

e42

-45

Del

ta V

42-4

6Ze

ro S

peed

42-4

7Ra

mp

Tim

e42

-48

S-ra

mp

Rat

io a

t D

ecel

. Sta

rt42

-49

S-ra

mp

Rat

io a

t D

ecel

. End

42-5

*SL

S42

-50

Cut Off

Spe

ed42

-51

Spee

d L

imit

42-5

2Fa

il Sa

fe R

eact

ion

42-5

3St

art

Ram

p42

-54

Ram

p D

own

Tim

e42

-6*

Safe

Fie

ldbu

s42

-60

Tele

gram

Sel

ectio

n42

-61

Des

tinat

ion

Add

ress

42-8

*St

atus

42-8

0Sa

fe O

ptio

n S

tatu

s42

-81

Safe

Opt

ion

Sta

tus

242

-82

Safe

Con

trol

Wor

d42

-83

Safe

Sta

tus

Wor

d42

-85

Activ

e Sa

fe F

unc.

42-8

6Sa

fe O

ptio

n In

fo42

-88

Supp

orte

d C

usto

miz

atio

n F

ile V

ersi

on42

-89

Cust

omiz

atio

n F

ile V

ersi

on42

-9*

Spec

ial

42-9

0Re

star

t Sa

fe O

ptio

n60

0-**

PRO

FIsa

fe60

0-22

PRO

FIdr

ive/

safe

Tel

. Sel

ecte

d60

0-44

Faul

t M

essa

ge C

ount

er60

0-47

Faul

t N

umbe

r60

0-52

Faul

t Si

tuat

ion

Cou

nter

601-

**PR

OFI

driv

e 2

601-

22PR

OFI

driv

e Sa

fety

Cha

nnel

Tel

. No.

Apendiks VLT® AutomationDrive FC 301/302

72 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

99

Page 75: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Indeks

AAC

Input AC............................................................................................... 15Sumber listrik AC.............................................................................. 15

Adaptasi motor otomatis................................................................... 20

Adaptasi Motor Otomatis (AMA)Peringatan.......................................................................................... 29

AlarmAlarm.................................................................................................... 23Daftar.................................................................................................... 24

AMAAMA...................................................................................................... 20

Lihat juga Adaptasi motor otomatis

AnalogOutput analog................................................................................... 47

ArusDC.......................................................................................................... 10input..................................................................................................... 15

Arus pendek........................................................................................... 26

BBerat.......................................................................................................... 57

DDaya

input..................................................................................................... 18Faktor daya......................................................................................... 16Rating daya........................................................................................ 57Sambungan daya............................................................................. 10

Delta dibumikan................................................................................... 15

Delta mengambang............................................................................ 15

Dimensi.................................................................................................... 57

EEfisiensi energi.......... 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 45

EN 50598-2.............................................................................................. 45

FFilter RFI.................................................................................................... 15

Fluks........................................................................................................... 22

GGambar urai.............................................................................................. 4

Getaran....................................................................................................... 8

GLCP.......................................................................................................... 19Lihat juga Panel kontrol lokal grafis

HHeat sink

Peringatan.......................................................................................... 30

IIEC 61800-3............................................................................................. 15

InputDaya input.............................................................. 10, 14, 15, 16, 23analog.................................................................................................. 46digital................................................................................................... 45Kabel daya input.............................................................................. 17Pemutus input................................................................................... 15Sinyal input........................................................................................ 30Terminal input............................................................................ 15, 18

Input analog........................................................................................... 24

Input denyut/enkoder........................................................................ 46

Instalasi kelistrikan............................................................................... 10

Instalasi mekanis..................................................................................... 8

Interferensi EMC.................................................................................... 14

Isolasi interferensi................................................................................. 16

Item dipasok............................................................................................. 8

KKabel

kontrol.................................................................................................. 14kontrol termistor.............................................................................. 15motor............................................................................................. 10, 14Panjang dan diameter kabel........................................................ 45Perutean kabel.................................................................................. 16Skema perkawatan.......................................................................... 13Spesifikasi kabel............................................................................... 45

Kabel berpelindung...................................................................... 14, 16

Kartu kontrolKartu kontrol........................................................................ 24, 47, 48Komunikasi seri................................................................................. 47Komunikasi seri USB....................................................................... 47Output DC, 10 V................................................................................ 47Peringatan.......................................................................................... 30RS485.................................................................................................... 47

Kebocoran arus................................................................................. 7, 10

Kehilangan fasa..................................................................................... 24

Kejutan........................................................................................................ 8

Keselamatan............................................................................................. 7

Ketidakseimbangan voltase............................................................. 24

KipasPeringatan................................................................................... 26, 31

Komunikasi seriKomunikasi seri................................................................................. 47Komunikasi seri USB....................................................................... 47RS485.................................................................................................... 47

Kondisi lingkungan.............................................................................. 45

Indeks Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 73

Page 76: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

KontrolKabel..................................................................................................... 10Kabel kontrol.............................................................................. 14, 16Karakteristik kontrol........................................................................ 48

Kontrol rem mekanis.................................................................... 15, 22

Kontroler eksternal................................................................................. 3

Konvensi.................................................................................................. 63

LLakukan.................................................................................................... 16

Letupan osilasi....................................................................................... 11

Level voltase........................................................................................... 45

Lingkungan............................................................................................. 45

Link DC..................................................................................................... 24

MMengangkat.............................................................................................. 9

Mengincir................................................................................................... 7

MotorDaya motor......................................................................................... 10Kabel motor......................................................................... 10, 14, 16Output motor.................................................................................... 44Performa output (U, V, W)............................................................. 44Peringatan................................................................................... 25, 27Proteksi kelebihan beban motor.................................................. 3Proteksi termal motor..................................................................... 21Putaran motor tanpa sengaja........................................................ 7Status motor......................................................................................... 3Terlalu panas...................................................................................... 25Termistor............................................................................................. 21Termistor Motor................................................................................ 21

OOutput

Digital output.................................................................................... 47Kabel daya output........................................................................... 17analog.................................................................................................. 47

Output DC, 10 V.................................................................................... 47

Output relai............................................................................................. 48

PPanel kontrol lokal grafis.................................................................... 19

Papan dayaPeringatan.......................................................................................... 30

Pelat Belakang.......................................................................................... 9

Pelat nama................................................................................................. 8

PELV........................................................................................................... 21

PemasanganDaftar periksa.................................................................................... 16Lingkungan pemasangan............................................................... 8

Pemasangan...................................................................................... 9, 16

Pemasangan sesuai EMC................................................................... 10

Pembagi beban................................................................................. 6, 23

PembumiKabel pembumi................................................................................ 10Pembumi............................................................................................. 16Peringatan.......................................................................................... 29Sambungan pembumi................................................................... 16

Pembumi................................................................................... 14, 15, 18

Pemecahan masalahPeringatan dan alarm..................................................................... 24

Pemeliharaan......................................................................................... 23

Pemrograman........................................................................................ 24

Pemutus rangkaian....................................................................... 16, 49

PendinginPeringatan.......................................................................................... 28

Pendinginan.............................................................................................. 8

Penyeimbangan potensi.................................................................... 11

Penyimpanan............................................................................................ 8

Peralatan opsional................................................................................ 14

Peralatan tambahan............................................................................ 16

Perfoma.................................................................................................... 48

PeringatanDaftar.................................................................................................... 24Peringatan.......................................................................................... 23

Perintah jarak jauh.................................................................................. 3

Perlindungan dari kelebihan arus.................................................. 10

Persetujuan Tipe...................................................................................... 5

Persiapan sistem................................................................................... 20

Persyaratan ruang bebas...................................................................... 8

Peruntukan................................................................................................ 3

RReferensi

Referensi.............................................................................................. 21

Reset................................................................................................... 23, 30

Resistor remPeringatan.......................................................................................... 27

RotorPeringatan.......................................................................................... 31

RS485RS485.................................................................................................... 47

Ruang bebas untuk pendinginan................................................... 16

SSafe Torque Off

Peringatan.......................................................................................... 30

Sakelar pemutus................................................................................... 18

Sekering.............................................................................. 10, 16, 28, 49

Sertifikasi.................................................................................................... 5

Servis......................................................................................................... 23

Simbol....................................................................................................... 63

Indeks VLT® AutomationDrive FC 301/302

74 Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. MG33AT9B

Page 77: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Singkatan................................................................................................. 63

Sinyal analog.......................................................................................... 24

Start tidak sengaja........................................................................... 6, 23

Sumber listrikMains supply (Catu Listrik)....................................... 38, 39, 40, 44

Sumber tambahan.................................................................................. 3

TTegangan tinggi............................................................................... 6, 18

Teknisi yang cakap.................................................................................. 6

Terminaloutput.................................................................................................. 18

Terminal input........................................................................................ 24

TermistorPeringatan.......................................................................................... 31

TorsiBatas..................................................................................................... 25Karakteristik torsi.............................................................................. 44

Torsi pengencangan penutup depan............................. 57, 59, 61

TripKunci trip............................................................................................. 23Trip.................................................................................................. 21, 23

UUkuran kabel................................................................................... 10, 14

Umpan Balik........................................................................................... 16

Umpan-balik sistem............................................................................... 3

VVoltase catu.............................................................................. 15, 18, 28

WWaktu pengosongan............................................................................. 6

Indeks Panduan Operasi

MG33AT9B Danfoss A/S © 05/2018 Semua hak dilindungi undang-undang. 75

Page 78: Panduan Operasi VLT AutomationDrive FC 301/302 0.25–75 kWfiles.danfoss.com/download/Drives/MG33AT9b.pdf · 9.1 Simbol, Singkatan, dan Konvensi 63 ... (0.34–10 hp) – 11–75

Danfoss tidak bertanggung jawab untuk berbagai kekeliruan yang mungkin ada dalam katalog, brosur dan materi cetak lainnya. Danfoss berhak mengubah produk-produknya tanpapemberitahuan. Hal ini juga berlaku untuk produk yang sudah dipesan, asalkan perubahan tersebut dapat dibuat tanpa pengubahan selanjutnya yang diperlukan dalam spesifikasi yang sudahdisepakati. Semua merek dagang dalam materi ini merupakan milik masing-masing perusahaannya. Danfoss dan jenis logo Danfoss adalah merek dagang Danfoss A/S. Semua hak dilindungiundang-undang.

Danfoss A/SUlsnaes 1DK-6300 Graastenvlt-drives.danfoss.com

*MG33AT9B*130R0300 MG33AT9B 05/2018