Post on 07-Feb-2023
1
Unauthorized reproduction of part or all of this manual’s content in any form is prohibited.
Product specifications may change without prior notice to improve functionality.
NITGEN&COMPANY the NITGEN logo are registered trademarks of NITGEN&COMPANYOther names and trademarks belong to respective companies.
The font used in this product is Naver’s “Nanum”.
© Copyright 2010, NITGEN&COMPANY Co., Ltd. All rights reserved.
NITGEN&COMPANY Customer Service CenterTel: +82.2.556.7115
Fax: +82.2.513.2191Email: customer@nitgen.com
Table of Contents2
FeaturesProduct ComponentProduct Description / LCD Display & Touch PanelSystem ConfigurationAuthenticationTime&Attendance ModeEntering Administrator MenuMenu (1~7)SpecificationTrouble Shooting (1~3)Information to the User
Features3
Remote control and real-time access monitoring by means of server program (AccessManager Pro.)
User’s setup function reinforced
Password/ RF card or any combination of the means
Touch Keypad with Backlight
IP65 rated waterproof & dustproof
CE, FCC certificated
Auto-on function
Shortcut ID matching opportunity provided
Various authentication media supported
LFD (Live Finger Detection)
Disabled @ RC/MC
4
Product Component
FingkeyAccessStandard
S/W CDBolts
AdapterPower Cord
Install Bracket
The FingkeyAccess includes the following components. For detailed information about installation, see the installation guide. If any of the following items is missing, contact the Customer Support Team
FingkeyAccessRC/MC
5
Product Description
5. Reset Button
1. LCD
2. Touch Panel
4. Card Input
3. Fingerprint Input
No Name Description
1 LCD The user can get information from it
2 Touch Panel The user can handle all inputs by touching.
3 Finger SensorThe user places his/her finger for authentication. (disabled @ RC/MC)
4 Card Input The user places his/her card for authentication.
5 Reset Button The user can make the system reset manually.
FINGKEY ACCESS
09:12:34
FINGKEY ACCESS
09:12:34 Network connection status
Initial message
EscapeENTER Key
Function Keys
(8) Menu
Cursor Key
LCD & Touch Pad
Front View
6
System Configuration
Components Access Server/Remote Manager/Remote Monitor# of accessible terminals ACM Pro.Max. 2,000 terminalsACM v2.57x Max. 255 terminals(available soon)# of accessible remote client PCs 8 clientsSupportable OS above Windows 2000# of users enrolled ACM Pro.100,000 users(SQL/SQL Express)ACM v2.57x 10,000 users(MDB/SQL) (available soon)
7
Authentication
Standard Model : Fingerprint, RF Card, Password
1. Maximize the finger area scanned and press evenly (70 ~ 80% of full pressure).
2. Place the “core” of the fingerprint at the center of the scanner. The core is usually opposite the whitish half-moon on the bottom of the fingernail. Therefore, place the half-moon part at the center of the scanner when scanning.
RC/MC Model : RF Card, Password
Correct Incorrect
8
Time&Attendance Mode
F3- INPUT ID
: 0324
General/Simple Mode
In attendance mode, function keys are displayed on the lower-right of the initial screen.
In Simple or General Attendance mode, the user must press a function key and input his ID to be authenticated. Function keys are as follows: F1: Coming to work F2: Leaving work F3: Going out F4: Returning
After the user presses a function key, the key will be included in the server log data which will be used by the attendance management program.
Auto/Extended Mode : Contact Sales Point.
Menu : Entering Administrator Menu9
To enter the Administrator menu, touch the “MENU” button at the lower of the touch pad.
Input the administrator ID and follow the authentication process. The Administrator menu will be displayed. Because no users have yet been registered, any user can enter the Administrator menu. At least one administrator for should be registered for security purposes.
INPUT MASTER ID
: 0324
If no administrator was designated and only general users were registered in network mode, all
users will be allowed to enter the Management menu.
10
Menu : User Management, FP option
3. Delete User
4. Delete All
1.User Manager
2. Modify User
1. Register User
2.FP Option 1. Brightness
2. Secu. Level
3. Capture Mode
4. Sensor Timeout
Disabled
6. 1:N Timeout
Delete 1 User
Delete All Users
Modify User Info.
Register User
Control Sensor Image
Set Security Level
Finger Capture mode
Set MaximumCapture Time
Set 1:N AuthenticationTimeout
Disable @ Network Mode
Disable @ RC/MC
11
Menu : UI option, System Option
1. Language
2. Buzzer
3.UI Option
4. FuncKey DIsp
4.System Option 1. LOG
2. RF Card
3. Wiegand
4. Function Mode
8. Timezone Mode
Disabled
5. Auth Mode
6. Time Setting
7. Terminal Mode
Select Language
Buzzer On/Off
Display type for Attendance
LOG On/Off
Select RF Card Type
Select 26/34 bit
AC/ T&A
Timezone On/Off
SO / NL
Current Time Setting
Set Wiegand output
Only @ T&A mode
SO = standalone modeNL = Network mode
AC = Access ControlT&A = Time & Attendance
Reader = Card NumberTerminal = Terminal ID
Mifare / HID / EM type
12
Menu : Network, Info., Factory
5.Network 1. Terminal ID
2. TCP/IP
3. N/W Timeout
4. Port Setting
6.Information 1. # of User
2. F/W version
7.Factory 1. DB Format
2. Factory Format
3. FP number
4. ID Length
5. Reset Term
User Data Format
Terminal Initialize
FP number per user
Set ID Length
Cold Reset Terminal
Read Number of User
Read F/W version
Set Terminal ID
Set TCP/IP info.
Network Timeout
Port Setting
This is FIXED option.Cannot be changed once user registered.
Option data, Log data remains.Not Deleted
DHCP settingTerminal IP, Server IPSubnet Mask, Gateway IP
Specification13
CPU : 32bit / 200MHzMemory : 8MB FlashDisplay : 128x32 Graphic LCD (Black&White)Sensor : OPP06 Optical Sensor, 500DPI (auto-ON, LFD) (only for Standard)Authentication Mode : Password, RF Card(HID/Mifare/EM)Template capacity : 1Finger 1,000 users & 2Finger 500 users(for Standard), 5,000 users (for RC/MC)Log capacity : 20,000 logsCommunication : TCP/IP, RS485, Wiegand(26/34 bits)Output Relay : Deadbolt, EM Lock, Door Strike, Automatic DoorOperating Temperature : -20 ~ 60℃ Operation Humidity : 10 ~ 90 %Certification : CE, FCCSize : 77(W) x 178(L) x 50(D) mm
14
Troubleshooting
<If RF card authentication fails>
Check your RF card type matches with the RF option of Terminal.
<If network connection cannot be established>
Check if the network setting is correct. Check the TCP/IP setting. ① IP address of the server where AccessManager Professional is installed.② The server and the terminal must use the same port. ④ Related settings if DHCP is not used. Synchronize the terminal and the server settings.
15
Troubleshooting
<If fingerprint authentication takes too long>
If the terminal uses 1:N authentication in network mode, server overload may occur, resulting in slow authentication and recognition. In this case, a dedicated server should be used.
Check if the finger and the sensor are clean. Clean the finger and the sensor. If the user’s finger is hurt, the user must register another fingerprint.
If the fingerprint is not clean, lower the security level of the user and use the 1:1 authentication method.
Input the user’s ID in 1:1 mode and check if the user exists.
<If fingerprint is not registered>
If the finger is too dry or humid, fingerprint image quality may be poor and may not register. Dry or moisturize the finger before registering the fingerprint.
16
Troubleshooting
<If the door does not open after authentication>Check the time period during which access is allowed. Check JP1 jumper status is correct. (refer to install guide)
<If users cannot be registered>In default configuration, this product operates in network mode which requires a
proper network connection for user registration. Check the network connection, or disable network mode to not use the network.
<If the product is unstable or does not function>In the terminal by selecting “Menu” “Reset” menu. Restart the server if the server management program is in use. If the terminal buttons do not function, restart the terminal by pushing external reset
button located right side of terminal.If the problem remains after the above actions are taken, contact the Customer
Support Team
17
Information to the user, 15.105(a)
For Class A digital device
INFORMATION TO THE USERThis equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
WARNING (Part 15.21)Any changes or modifications not expressly approved by the manufacturer could void
the user’s authority to operate the equipment