WX6103-CMW520-R2115P15 Release Notes Keywords: WLAN, Version Information, Version Update, Open Problems and Workarounds,
Abstract: The explication for this version, hardware features, software features and their operation and the software upgrade guide. Unresolved Problems and Avoidance Measure, Version Compatibility, Software Upgrading and so on.
Abbreviations:
Abbreviations Full spelling AAA Authentication, Authorization and Accounting
AC Access Controller
ACL Access Control List
AP Access Point
ADOS
ARP Address Resolution Protocol
CCMP Counter mode (CTR) with CBC-MAC Protocol
CLI Command Line Interface
DHCP Dynamic Host Configuration Protocol
MIB Management Information Base
Qos Quality of Service
SNMP Simple Network Management Protocol
STA Station
TKIP Temporal Key Integrity Protocol
WEP Wired Equivalent Privacy
WLAN Wireless LAN
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 3
Table of Contents
Version Information·················································································································6 Version Number ·······················································································································6 Version History··························································································································6 Hardware and Software Compatibility Matrix··············································································7 FIT AP Compatibility Table ·········································································································9
Restrictions and Cautions ······································································································ 10
Feature List··························································································································· 10 Hardware Features················································································································· 10 Software Features ·················································································································· 13
Version Updates ··················································································································· 14 Feature Updates ···················································································································· 14 Command Line Updates········································································································· 17 MIB Updates ·························································································································· 17 Configuration Changes ·········································································································· 17
Open Problems and Workarounds ·························································································· 18
List of Resolved Problems ······································································································· 18 Resolved Problems in WX6103-CMW520-R2115P15 ····································································· 18 Resolved Problems in WX6103-CMW520-R2115P12 ····································································· 19 Resolved Problems in WX6103-CMW520-R2115P10 ····································································· 20 Resolved Problems in WX6103-CMW520-R2115P08 ····································································· 21 Resolved Problems in WX6103-CMW520-R2115P07 ····································································· 22 Resolved Problems in WX6103-CMW520-R2115P05 ····································································· 24 Resolved Problems in WX6103-CMW520-R2115P04 ····································································· 24 Resolved Problems in WX6103-CMW520-R2115 ·········································································· 25 Resolved Problems in WX6103-CMW520-E2112 ·········································································· 29 Resolved Problems in WX6103-CMW520-B2111P01 ····································································· 30 Resolved Problems in WX6103-CMW520-B2111/B2102································································· 31 Resolved Problems in WX6103-CMW520-B2111 ·········································································· 31 Resolved Problems in WX6103-CMW520-R2109P08 ····································································· 32 Resolved Problems in WX6103-CMW520-R2109P06 ····································································· 32 Resolved Problems in WX6103-CMW520-R2109P05 ····································································· 32 Resolved Problems in WX6103-CMW520-R2109P04 ····································································· 33 Resolved Problems in WX6103-CMW520-R2109P03 ····································································· 33 Resolved Problems in WX6103-CMW520-R2109P01 ····································································· 33 Resolved Problems in WX6103-CMW520-R2109 ·········································································· 33
Related Documentation········································································································ 34 New Feature Documentation·································································································· 34 Documentation Set ················································································································ 34 Obtaining Documentation······································································································ 34
Software Upgrading·············································································································· 34 Overview ······························································································································ 34
Files Managed by the Access Controller ············································································ 35 BootWare Program File ···································································································· 35 Application Files ·············································································································· 35 Configuration Files ··········································································································· 36 Approaches for Software Maintenance············································································· 36 Software Upgrade Flow···································································································· 37
BootWare Menus ··················································································································· 37
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 4
BootWare Main Menu······································································································ 37 BootWare Submenus ······································································································· 39
Upgrading the BootWare········································································································ 40 Modifying Serial Communication Parameters ····································································· 41 Upgrading the BootWare Through the Management Ethernet Interface ······························· 43 Upgrading the BootWare Through a Serial Connection ······················································· 45
Upgrading Applications Through a Serial Connection ································································ 48 Upgrading Applications through an Ethernet Interface ······························································ 49
Configuring Ethernet Interface Parameters ········································································ 49 Upgrading Applications Through the Management Ethernet Interface ································· 49
Maintaining the Application and Configuration Files Through the CLI ·········································· 51 Maintaining the Access Controller Through TFTP·································································· 51 Maintaining the Access Controller Through FTP ··································································· 52
Maintaining Application and Configuration Files ······································································· 55 Dealing with Password Loss ····································································································· 57
User Password Loss··········································································································· 57 BootWare Password Loss ·································································································· 58 Super Password Loss ········································································································ 58
Backing Up and Restoring the BootWare ·················································································· 58 Notes for upgrading FIT AP ······································································································ 59
Interim version for WA2100································································································ 59 Interim version for WA2200································································································ 59
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 5
List of Tables
Table 1 Version history.................................................................................................................................6
Table 2 Hardware and software compatibility matrix ...........................................................................7
Table 3 WX Series Access Controller Module Compatibility Table ......................................................8
Table 4 WX6103 Access Controller Security Module Compatibility Table..........................................8
Table 5 Fit AP Compatibility Table ............................................................................................................9
Table 6 WX6103 Hardware Features...................................................................................................... 10
Table 7 LSQM1WCMB0 Hardware Features ......................................................................................... 11
Table 8 LSBM1WCM2A0 Hardware Features........................................................................................ 12
Table 9 LSRM1WCM2A1 Hardware Features........................................................................................ 12
Table 10 Software Features of access controller module.................................................................. 13
Table 11 Feature Updates....................................................................................................................... 14
Table 12 Command line updates .......................................................................................................... 17
Table 13 New Feature Documentation ................................................................................................ 34
Table 14 Documentation set .................................................................................................................. 34
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 6
Version Information
Version Number Comware Software, Version 5.20, Release 2115P15
Note: This version number can be displayed by command display version under any view. Please see Note①.
Version History Table 1 Version history
Version Number Last version Release Date Remark
WX6103-CMW520-R2115P15 WX6103-CMW520-R2115P12 2011-1-21 None
WX6103-CMW520-R2115P12 WX6103-CMW520-R2115P10 2010-12-2 None
WX6103-CMW520-R2115P10 WX6103-CMW520-R2115P08 2010-11-1 None
WX6103-CMW520-R2115P08 WX6103-CMW520-R2115P07 2010-8-31 None
WX6103-CMW520-R2115P07 WX6103-CMW520-R2115P05 2010-8-17 None
WX6103-CMW520-R2115P05 WX6103-CMW520-R2115P04 2010-6-30 None
WX6103-CMW520-R2115P04 WX6103-CMW520-R2115 2010-6-10 None
WX6103-CMW520-R2115 WX6103-CMW520-E2112 2010-5-7 None
WX6103-CMW520-E2112 WX6103-CMW520-B2111P01 2009-12-17 None
WX6103-CMW520-B2111P01 Wx6103:WX6103-CMW520-B2111
LSRM1WCM2A1: WX6103-CMW520-B2102
2009-10-31 None
Wx6103:WX6103-CMW520-B2111
LSRM1WCM2A1: WX6103-CMW520-B2102
First release on new branch 2009-7-21 None
WX6103-CMW520-R2109P10 WX6103-CMW520-R2109P08 2009-6-26 None
LSRM1WCM2A1:WX6103-CMW520-B2101P01 First release 2009-6-26 None
WX6103-CMW520-R2109P08 WX6103-CMW520-R210906 2009-6-21 None
WX6103-CMW520-R2109P06 WX6103-CMW520-R210905 2009-5-21 None
WX6103-CMW520-R2109P05 WX6103-CMW520-R210904 2009-4-17 None
WX6103-CMW520-R2109P04 WX6103-CMW520-R210903 2009-3-23 None
WX6103-CMW520-R2109P03 WX6103-CMW520-R210901 2009-2-21 None
WX6103-CMW520-R2109P01 WX6103-CMW520-R2109 2008-12-12 None
WX6103-CMW520-R2109 First time. 2008-11-6 None
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 7
Hardware and Software Compatibility Matrix Table 2 Hardware and software compatibility matrix
Hardware Platform Wireless Controller series Product family WX6000 series
Hardware platform
H3C WX6103 Access Controller
H3C LSQM1WCMB0 Access Controller Module
H3C LSBM1WCM2A0 Access Controller Module
H3C LSRM1WCM2A1 Access Controller Module
Minimum memory requirements 1GB
Minimum Flash requirements 256M CF Card
Boot ROM Version
EWPX1WCMB0/ LSQM1WCMB0/ LSBM1WCM2A0/ LSRM1WCM2A1:
Basic 1.14 Extend 1.18
(Note: This version number can be displayed by command display version under any view of Main control board. Please see Note②)
EWPX1G24XA0(Switch interface board):
Basic 1.15 Extend 1.17
(Note: This version number can be displayed by command display version under any view of Switch interface board. Please see Note③)
Host Software WX6103-CMW520-R2115P15.bin (31,779,508 Bytes)
iMC Version
iMC PLAT 3.20-R2606 + P13 + L15
iMC QoSM 3.20-F0606
iMC UAM 3.60-E6301 + P04
iMC WSM 3.50-C5303 + P01
iMC EAD 3.60-E6301 + P04
iNode iNode PC 3.60-E6307
AP Version
WA2100-CMW520-R1112P07
WA2200-CMW520-R1115P09
WA2600-CMW520-R1109P04
WA2600A-CMW520-R1106P04
Remark
For R2115P08 and later versions, two certificate files named h3c-wlan_ca.cer and h3c-wlan_local.pfx were packed in the software package, which could be used by WEB in HTTPS mode. The password for h3c-wlan_local.pfx is h3c.
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 8
Table 3 WX Series Access Controller Module Compatibility Table
WX Series Access Controller Module Software Version Frame Software Version
LSRM1WCM2A1 WX6103-CMW520-B2102(WCMR200R001B71D002)and later version
H3C S9505E
H3C S9508E-V
H3C S9512E
S9500E-CMW520-A1132 and later version
The latest version: S9500E-CMW520-R1238P08
LSQM1WCMB0 WX6103-CMW520-R2109 (WCMV200R001B58D000SP01) and later version
H3C S7510E
H3C S7506E-V
H3C 7506E
H3C 7503E
H3C 7502E
S7500E-CMW520-E6200 and later version
The latest version: S7500E-CMW520-R6616P02
LSBM1WCM2A0 WX6103-CMW520-R2109 (WCMV200R001B58D000SP01) and later version
H3C S9512
H3C S9508
H3C S9508V
H3C S9505
S9500-CMW310-F2130 and later version
The latest version: S9500-CMW310-R1652P03
Table 4 WX6103 Access Controller Security Module Compatibility Table
WX6103 Access Controller Security Module
Software Version Frame Software Version
EWPXM1FWA0
SECBLADEIAG-CMW520-E7501 and later version
The latest version: SECBLADEIAG-CMW520-E7504P22
H3C WX6103 WX6103-CMW520-R2109P11 and later version
CAUTION: Specific explanation must be given as to such issues as backward compatibility.
To display the host software and BootWare version of the WX6000 series access controller module, perform the following: <H3C>display version
H3C Comware Platform Software
Comware Software, Version 5.20, Release 2115P15 ------ Note①
Copyright (c) 2004-2010 Hangzhou H3C Tech. Co., Ltd. All rights reserved.
H3C WX6103 uptime is 0 week, 0 day, 0 hour, 13 minutes
H3C WX6103 with 1 BCM MIPS 1125H 600MHz Processor
1024M bytes DDR
259M bytes CFCard Memory
Config Register points to CFCARD
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 9
Hardware Version is VER.B
CPLD Version is CPLD 010
Backboard CPLD Version is CPLD 003
Basic Bootrom Version is 1.14 ------ Note②
Extend Bootrom Version is 1.18 ------ Note②
[Subslot 0]EWPX1WCMB0 Hardware Version is VER.B
To display the host software and BootWare version of the switch interface board of WX6103, perform the following command on switch interface board: <H3C>display version
H3C Comware Platform Software
Comware Software, Version 5.20, Release 2115P10 ------ Note①
Copyright (c) 2004-2010 Hangzhou H3C Tech. Co., Ltd. All rights reserved.
H3C EWPX1G24XA0 uptime is 0 week, 0 day, 0 hour, 0 minute
Solt 0
H3C EWPX1G24XA0 with 1 Freescale MPC 8248 400MHz Processor
256M bytes SDRAM
16M bytes Flash Memory
Config Register points to FLASH
Hardware Version is VER.B
CPLD Version is CPLD 004
Basic Bootrom Version is 1.15 ------ Note③
Extend Bootrom Version is 1.17 ------ Note③
[Subslot 0]EWPX1G24XA0 Hardware Version is VER.B
FIT AP Compatibility Table Table 5 Fit AP Compatibility Table
AP Type AP Mode File Name Packed with AC Version Remark
H3C WA2110-AG WA2100 None
3COM 7760 7760_2750(Note④) None
3COM 8760 8760_3150 None
3COM 3150 8760_3150
wa2100.bin Yes
None
H3C WA2210-AG WA2210-AG None
H3C WA2220-AG WA2220-AG None
H3C WA2210X-G WA2210X-G None
H3C WA2220X-AG WA2220X-AG
wa2200_fit.bin Yes
None
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 10
AP Type AP Mode File Name Packed with AC Version Remark
H3C WA2610E-AGN WA2610E-AGN None
H3C WA2620E-AGN WA2620E-AGN wa2600_fit.bin Yes
None
H3C WA2612-AGN WA2612-AGN None
H3C WA2620-AGN WA2620-AGN w2600a_fit.bin Yes
None
NOTE③: Hereby 7760_2750 is only used as a model name in the AC software. 7760 is supported but 2750 is not.
Restrictions and Cautions 1. The size of configure file for Fit AP shouldn’t be more than 3500 bytes. 2. To upgrade WA2100(previous to R1106P03), WA1208E(previous to R1107P01) and
WA2200(previous to R1109P01), you should upgrade them using the interim version files firstly, and then upgrade them using the compatible version files, refer to section Notes for upgrading FIT AP ).
3. If update to current version base "WX6103-CMW520-R2109P01" or earlier version, Device will update CPLD automatically. For taking the new CPLD effect, the device must be powered off and on again.
4. Port security mode “userlogin-secure-ext-or-psk”is not recommended. Some wireless adaptor station can’t connect with this mode.
5. Configuration file created or saved on R2115P07 or later version could not be used by the version previous to R2115P07, otherwise the configuration of AP Profiles in the configuration file would be lost.
6. AC using R2115P07 or later version could not be degraded to versions between E2112 and R2115 directly,an interim version (such as R2115P05 or R2115P04) should be used firstly.
Feature List
Hardware Features Table 6 WX6103 Hardware Features
Item WX6103 Dimensions(H × W × D)
(excluding feet and rack-mounting brackets)
176 × 436 × 420 mm (6.9 × 17.2 × 16.5 in.)
Weight 25.2Kg (55.6lb)
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 11
Item WX6103
Input voltage
AC:
rated voltage: 100V~240V AC;50/60Hz
tolerance voltage: 90V~264V AC; 47/63Hz
DC:
rated voltage: -52V~-55V DC
tolerance voltage: -36V~-72V DC
Max. power consumption Main control board: <75W
Switch interface board: <65W
Operating temperature 0℃~45℃(32°F to 113°F)
Relative humidity (noncondensing) 5%~ 95%
Processor 600MHz
Memory 1GB
CF Flash 256M
Fixed interfaces
Switch interface board:
24-GE, 4-SFP (Combo), 1-Slot
Main control board:
2×USB(support USB1.1)
1×10/100/1000Base-T
1×Console
Table 7 LSQM1WCMB0 Hardware Features
Item Description
Dimensions(H × W) 366.7mm×340mm
Weight 3.3kg(7.28 lb)
Input AC voltage /
Max. power consumption 80W
Operating temperature 0℃~45℃(32°F to 113°F)
Relative humidity (noncondensing) 5%~ 95%
Processor 600MHz
BootWare 512KB
Memory 1GB
CF Flash 256MB
Fixed interfaces
2×USB(support USB1.1)
1×10/100/1000Base-T
1×Console
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 12
CPU BCM1125+XLR732
SDRAM 1GB
Table 8 LSBM1WCM2A0 Hardware Features
Item Description
Dimensions(H × W) 366.7mm×340mm
Weight 3.58kg(7.89 lb)
Input AC voltage /
Max. power consumption 115W
Operating temperature 0℃~45℃(32°F to 113°F)
Relative humidity (noncondensing) 5%~ 95%
Processor 600MHz
BootWare 512KB
Memory 1GB
CF Flash 256MB
Fixed interfaces
2×USB(support USB1.1)
1×10/100/1000Base-T
1×Console
CPU BCM1125+XLR732
SDRAM 1GB
Table 9 LSRM1WCM2A1 Hardware Features
Item Description
Dimensions(H × W × D) 366.7mm×340mm×40.6mm
Weight 3.58kg(7.89 lb)
Input AC voltage /
Max. power consumption 105W
Operating temperature 0℃~45℃(32°F to 113°F)
Relative humidity (noncondensing) 5%~ 95%
Processor 600MHz
Memory 1GB
CF Flash 256MB
Fixed interfaces
2×USB(support USB1.1)
1×10/100/1000Base-T
1×Console
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 13
Software Features Table 10 Software Features of access controller module
Category Features WX6103/ LSQM1WCMB0/ LSBM1WCM2A0 AP Number AP Number 128 to 640
L2 protocol
802.3x、802.1p、802.1q、802.1x
Port Loop-Back
Port Broad-Storm-Suppression
802.11 protocol
802.11、802.11b、802.11g、802.11a、802.11n、802.11e
Transmit Data Rate Selection
Channel Selection
Power Constraint Selection
CAPWAP protocol
Support CAPWAP
Support IPV6
Support L2/L3
Support TCP、UDP、IP Option
IP application Ping 、Trace、DHCP Server 、DHCP Client、 DNS client 、DNS Static、 NTP 、Telnet 、TFTP Client 、FTP Client 、FTP Server
IP routing Static routing
Multicast IGMP snooping
MLD snooping
Networks
IPv6 Basic functions: IPv6 ND, IPv6 PMTU, and IPv6 ACL
Static routing
Authentication MAC authentication, 802.1x(EAP-TLS、EAP-TTLS、EAP-PEAP 、EAP-SIM、EAP-MD5), Portal, PPPoE
AAA Local authentication、Radius、HWTacacs
802.11 Security 802.11i, WPA/WPA2
Encryption: WEP(WEP64/WEP128), TKIP, AES-CCMP
WIDS/WIPS Rogue AP Detection, White-list, Black-list
Flood attack detection, Weak IV detection, Spoof Attack detection
Security features
Others SSH V1.5/2.0
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 14
Category Features WX6103/ LSQM1WCMB0/ LSBM1WCM2A0
L2 QoS
Flow classification: Based on port, MAC address, IP address, IP priority, DSCP priority, TCP/UDP port No. and protocol type
Traffic policing: CAR (granularity configurable)
Priority Mark/Remark
QOS
Wireless QoS WMM (802.11e)
RF Manage RF Manage
Auto AP power adjust
Auto DFS
Auto channel selection
AP load balance: base traffic or session
Management SNMP V1/V2c/V3, MIB, SYSLOG, RMON
Console port
Access Console, Telnet, SSH, FTP Management and maintenance
File system Support File system
Support Dual Image
Version Updates
Feature Updates Table 11 Feature Updates
Version number Item Description
Hardware feature updates
Modify: 1. Main control board CPLD up to 010 WX6103-CMW520-
R2115P12 Software feature updates
New: 1. Support a new AP model named WA2620X-AGNP.
Hardware feature updates
Modify:
Main control board BOOTWARE extend up to extend 1.18 WX6103-CMW520-
R2115P10 Software feature updates
New: 1. The number of APs which can be bound with
Mesh-profile is increased to 640.
WX6103-CMW520-R2115P08
Hardware feature updates
Modify:
Main control board BOOTWARE extend up to extend 1.17
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 15
Software feature updates
New: 1. Max. user number that per AP Radio increase to
124 (default 64) 2. Selected Country Code shouldn’t be saved
automatically 3. Support adding wlan-tunnel to vlan manually 4. Modify Radius timer quiet to include 0 value 5. WEB interface support different shared secret
(Radius key) for secondary server
Hardware feature updates NA
WX6103-CMW520-R2115P07 Software feature
updates
New: 1. Support Aeroscott 2. Support LEAP Protocol 3. Support VRRP Protocol 4. Support GDB. 5. Extend the hardware version of some AP models:
9152 extend to Ver.F, WA2100 extend to Ver.E, WB2320X-AGE extend to Ver.D, WA2610X-GNP extend to Ver.B, WB2360X-ANP extend to Ver.B.
6. For the instance of AC 1+1 hot-backup, ACs need not backup information of wireless clients.
Hardware feature updates
Modify: 1. Switch interface board BOOTWARE up to basic
1.15, extend1.17 WX6103-CMW520-R2115P05
Software feature updates
New: 1. Upgrade the version of switch interface board.
Hardware feature updates
Modify: 1. Main control board CPLD up to 009
WX6103-CMW520-R2115P04 Software feature
updates
New: 1. Support Portal Proxy. 2. Support periodic statistics of different types of CPU
packets.
WX6103-CMW520-R2115
Hardware feature updates
Modify: 1. Main control board BOOTWARE up to basic 1.14,
extend1.16 2. Switch interface board BOOTWARE up to basic
1.15, extend1.15
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 16
Software feature updates
New: 1. Modify the maximum number of DBSS to 7680 on
AC. 2. Deletes Backhaul Link Rate from MESH feature. 3. Modify ARP rate-limit on AC. ARP rate-limit is
disabled by default and the maximum value is up to 3K.
4. Modify the maximum number of SSID to 512. 5. Support a new AP model named WA1208E-GP-H20 6. Support the requirements of LOAD BALANCE
GROUP and RRM for Australia. 7. Modify the heartbeat interval of AC hot-backup to
2000ms, and the backup AC needs not to maintain the backup information of wireless users in this version.
8. Modify the format of WLAN interface to SSID+Encrypt-type in DHCP Snooping and ARP Detection pages on WEB.
Hardware feature updates NA
WX6103-CMW520-E2112 Software feature
updates
New: 1. Support new AP mode WA2610E-GNP and modify
the antenna lists for WA2610X-GNP and WB2360X-ANP.
Hardware feature updates
Modify:
Main control board BOOTWARE up to basic 1.13 and extend1.15
WX6103-CMW520-B111P01
Software feature updates
New: 1. Support idle-cut for Portal and PPPoE. 2. Support new AP model: 3Com 9152、WA2610X-
GNP and WB2360X-ANP. 3. Support MIB of Guangdong Telecom. 4. Support default ARP rate-limit on GE and ESS ports. 5. Support user-defined local-Portal WEB pages.
Hardware feature updates NA
WX6103-CMW520-R2109P08 Software feature
updates
New: 1. Support user-defined WEB pages for local Portal
server. 2. Support AP model of 9552.
Hardware feature updates NA
WX6103-CMW520-R2109P06 Software feature
updates
New: 1. MAC authentication support different domains for
different SSIDs.
WX6103-CMW520-R2109P05
Hardware feature updates NA
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 17
Software feature updates
New: 1. Support APs types of WA2610-AGN 、 WA2612-
AGN、WA2620-AGN、9150、9550
2. Portal authentication support different WEB pages for different SSIDs, and Portal WEB pages can be linked to the former URL.
Hardware feature updates NA
WX6103-CMW520-R2109P04 Software feature
updates New: 1. Select power range by channel
Hardware feature updates
Modify: 1. Main control board CPLD up to 008;Bootrom up
to basic 1.12extend1.13 2. Switch interface board CPLD up to 004
WX6103-CMW520-R2109P03
Software feature updates
New: 1. Select power by antennas
Command Line Updates Table 12 Command line updates
Version number Item Description
WX6103-CMW520-R2115P08 Modify commands
1. Command 1: client max-count max-number
Description: parameter modify to 1-124 2. Command 2: member { ip ipv4-address | ipv6
ipv6-address } [ vlan vlanid ].
Description: Adding parameter vlan to support adding wlan-tunnel to vlan manually.
WX6103-CMW520-R2115P07 New commands
1. Command: undo wep mode dynamic
Description:Set dynamic WEP key mode by LEAP 2. Command about VRRP, Please refer
Command Manual for detail.
MIB Updates NA.
Configuration Changes NA.
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 18
ion: CMW520-R2115
• cket was dropped for some
uld not pass 802.1xauthentication.
rob
n: CMW520-R2115P12
• ription: After AC had been upgraded to R2115P12, some LWAPP packets P were too big, which might cause the AP could not connect with
time AC would send wrong TRAP with the information The number llocated IP address in 5 minutes overflows.
• Condition: None.
• Description: NAS IP in RADIUS scheme could not be configured as X.X.X.255.
Open Problems and Workarounds Problem WLD27552
• First Found-in Version: CMW520-R2115P10
• Condition: iPhone4 connected with AC by encrypted service-template.
• Description: GTK re-negotiation would fail because of wrong Key Length value in key negotiation packet sent by iPhone4.
• Avoidance: iPhone4 would reconnect quickly after GTK re-negotiation failure.
Problem WLD24879
• First Found-in Vers
• Condition: None
Description: A wireless user connected AC by WPA2 mode and 802.1x authentication. During the 802.1x authentication, if EAP-success pareason, the user co
• Avoidance: None
List of Resolved Problems
Resolved Problems in WX6103-CMW520-R2115P15
P lem WLD28034
• First Found-in Versio
• Condition: None.
Descbetween AC and AAC.
Problem WLD27809
• First Found-in Version: CMW520-R2115P12
• Condition: None.
• Description: Someof DHCP server a
Problem ZDD03598
• First Found-in Version: CMW520-R2115P12
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 19
• e prompt information is ’Maximum Monitor AP configuration limit has
• Avoidance: None
Problem W
ion: CMW520-R2115P10
• n before R2115P05 to version R2115P10 ould not start up normally.
the 1x authentication, if LEAP authentication failed, it might cause ot pass PEAP authentication.
• configuring Radius scheme by WEB, a blank in the authentication
key might cause error on the WEB page.
rob
• ion: CMW520-R2115P10
ces were
t cause high CPU usage on AC.
Problem WLD27633
• First Found-in Version: CMW520-R2115P10
• Condition: Many APs had connected with AC, and many DBSS interfaces were created on AC. ARP Snooping was enabled on AC.
• Description: ARP burst in network might cause some APs going offline.
Problem WLD27281
• on: CMW520-R2115P09 First Found-in Versi
• Condition: None
Description: Sometime it would fail to configure an AP to be running in Monitor mode on AC. Threached.’
Resolved Problems in WX6103-CMW520-R2115P12
LD27620
• First Found-in Vers
• Condition: None
Description: Upgrading WX6103 from versiomight cause AC c
Problem WLD27606
• First Found-in Version: CMW520-R2115P10
• Condition: Wireless client connected with AC by 802.1x authentication. On RADIUS server, LEAP is the primary authentication and PEAP is secondary.
• Description: Duringclient also could n
Problem WLD26441
• First Found-in Version: CMW520-R2115P05
Condition: None
• Description: During
P lem WLD26575
First Found-in Vers
• Condition: Many APs had connected with AC, and many DBSS interfacreated on AC.
• Description: Enabling DHCP Snooping migh
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 20
• CMW520-R2115P10
lients were
Resolved Problems in WX6103-CMW520-R211 P
• 8
ct with WLAN network by WPA+TKIP mode, by RSN+TKIP mode.
• on: CMW520-R2115P08
neously might cause some TRAPs about AP
on: CMW520-R2115P08
• dress of the Portal server was always displayed in the Portal WEB h the URL for Portal server was configured with domain name on AC.
Problem W
•
Prob
on: CMW520-R2115P05
l authentication would not take effects on user’s data packets
Problem ZDD03416
First Found-in Version:
• Condition: None
• Description: Full DHCP security table might cause reply packets for DHCP csent in wrong VLAN.
5 10 Problem WLD27032
First Found-in Version: CMW520-R2115P0
• Condition: None
• Description: NOKIA N95 could not connebut could connect
Problem WLD26457
First Found-in Versi
• Condition: None
• Description: Many APs going online simultalost.
Problem WLD26457
• First Found-in Versi
Condition: None
• Description: IP adpage even thoug
LD25875
First Found-in Version: CMW520-R2115P05
• Condition: None
• Description: URL information for Local-Portal Server could not be configured by WEB.
lem WLD26455
• First Found-in Versi
• Condition: None
• Description: Portareceived from IACTP tunnel on AC.
Problem WLD22291
• First Found-in Version: CMW520-R2115P05
• Condition: None
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 21
alue of MESH links on WEB was not calculated correctly.
ion: CMW520-R2115P05
s of FLASH and memory of AC on WEB was not displayed correctly.
Problem W
ion: CMW520-R2115P05
•
n: None
quiet timer was set to be zero and the primary Radius server had ould still send Radius packets to the primary server firstly and then
a long time for the wireless user to pass the
Reso vR211
• time AC sent Device-reboot TRAP to iMC but actually AC did not
reboot at all.
• time QoS policy had been applied on ESS port but some error
rinted out.
• • Description: Sometime after user roamed to another AC and went offline, client
information was still remained on FA , which might cause the user could not re-authenticated by AC in several minutes.
• Description: PER v
Problem WLD26434
• First Found-in Vers
• Condition: None
• Description: Value
LD26467
• First Found-in Vers
• Condition: None
Description: During configuring IPv6 roam-group by WEB, if blank was included in the authentication key, the configured roam-group would not work up.
Problem WLD26556
• First Found-in Version: CMW520-R2115P05
• Conditio
• Description: If thebeen down, AC wswitch to the secondary, which might take802.1x authentication.
l ed Problems in WX6103-CMW520-5P08
Problem ZDD03237
• First Found-in Version: CMW520-R2115P05
Condition: None
• Description: Some
Problem WLD26247
• First Found-in Version: CMW520-R2115P05
Condition: None
• Description: Someinformation was p
Problem WLD26160
• First Found-in Version: CMW520-R2115P05
Condition: None
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 22
d-in Version: CMW520-R2115P07
n: None
re-authentication can fail during 11key 4-handshake for some wireless adapter such as DWA-547.
Resolved Problems in WX6103-CMW520-R2115P
Problem WLD26340
ion: CMW520-R2115P05
• oading version file form AC by BOOTWARE mode might cause
ion: CMW520-R2115P05
om 8020 WiFi phone could not pass through 802.1x authentication
ld not be read.
• •
time the connection of user’s telnet on AC could not be deleted.
Problem WLD25749
ion: CMW520-R2115P05
• f a P Failure packet would be sent to the user by AC but no De-
authentication frame, which would cause the user could not re-authenticated by AC
• First Found-in Version: CMW520-R2115P04
Problem WLD26359
• First Foun
• Conditio
• Description: STA
07
• First Found-in Vers
• Condition: None
Description: AP downlexception on AC.
Problem WLD25567
• First Found-in Vers
• Condition: None
• Description: Polycon AC.
Problem WLD25883
• First Found-in Version: CMW520-R2115P05
• Condition: None
• Description: Some MIB nodes of DHCP cou
Problem WLD25792
First Found-in Version: CMW520-R2115P05
Condition: None
• Description: Some
• First Found-in Vers
• Condition: None
Description: f EAP Request packets were lost during authentication process owireless user, EA
for several minutes.
Problem WLD25606
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 23
more than 3500 Bytes, after the file had been the file probably would be lost on AP.
•
of DEV task was more than 30 percents.
•
wireless user going offline was incorrect, it was ine.
• 15
d not be changed if the related WLAN service-d. It should prompt warning information.
on:CMW520-R2115
• Condition: None
uding the illegal letter “-” might cause the ration failed.
ob
on:CMW520-R2115
twork management system, sometime the sum-online-time statistic
Prob
on:CMW520-R2115
n transforming an auto AP to persistent one, if the AP’s name
Prob
First Found-in Version:CMW520-R2115
• Condition: None
• Description: If size of the MAP file wasP, some configurations indownloaded to A
Problem WLD25338
First Found-in Version: CMW520-R2115
• Condition: None
• Description: Sometime the CPU usage
Problem WLD25348
First Found-in Version: CMW520-R2115
• Condition: None
• Description: Sometime the statistic of tistic of wireless user going onlmore than the sta
Problem WLD24719
First Found-in Version:CMW520-R21
• Condition: None
• Description: Configuration of ESS coultemplate had been enable
Problem WLD25291
• First Found-in Versi
• ring AP’s name incl Description: Configuquick start configu
Pr lem WLD25154
• First Found-in Versi
• Condition: None
• Description: In neof all wireless user for one AP was incorrect.
lem WLD24921
• First Found-in Versi
• Condition: None
• Description: Wheincluded a uppercase letter, the transformation would fail.
lem WLD25291
• Condition: None
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 24
Problem W 20
n: None
ring a QoS policy with character “#” in its name might cause .
ion:CMW520-E2112
Kwajalein” n could not
Resolved Problems in WX6103-CMW520-R211 P
• 0-R2115
of DEV task was more than 30 percents.
Reso vR211
ion:CMW520-R2115
trum-management on AC might cause wireless users in 11a mode t with AC.
• Description: After wireless interface on AC was disabled by intrusion protection, AC th the wireless interface.
• n:CMW520-R2115
• Description: Quick start configuration might cause the configurations of GE ports in a link-aggregation group changed.
LD240
• First Found-in Version:CMW520-E2112
• Conditio
• Description: Configuerror on WEB page
Problem WLD24742
• First Found-in Vers
• Condition: None
• Description: After configuring AC’s time-zone to be such as “Eniwetok,during quick start and then rebooting the AC, the time-zone configuratiotake effect.
5 05 Problem WLD25338
First Found-in Version:CMW52
• Condition: None
• Description: Sometime the CPU usage
l ed Problems in WX6103-CMW520-5P04
Problem WLD25063
• First Found-in Vers
• Condition: None
• Description: Speccould not connec
Problem WLD23702
• First Found-in Version:CMW520-R2115
• Condition: None
would force to reboot the AP related wi
Problem WLD24719
First Found-in Versio
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 25
s in its serial-id could not connect with AC by
• -in Version:CMW520-R2115
lem ZDD03002
on:CMW520-R2115
cause part of SNMP packets would be
Resolved Problems in WX6103-CMW520-R211
erver was used on AC
• ut the last time to reset counters on L2 interface.
ob
• First Found-in Version:CMW520-E2112
• Condition: None
• Description: AP with lowercase letterauto mode.
Problem WLD23892
First Found
• Condition: None
• Description: Firefox could not display the whole statistics of 11N type radio.
Prob
• First Found-in Versi
• Condition: None
• Description: SNMP request burst mightdropped on AC .
Problem WLD25118
• First Found-in Version:CMW520-R2115
• Condition: None
• Description: iMC could not display the control panel of Main control board on WX6103.
5Problem WLD23228
• First Found-in Version:CMW520-E2112
• Condition: Local-s
• Description: GTK was not re-negotiated during 802.1x re-authentication process.
Problem WLD22677
• First Found-in Version:CMW520-E2112
• Condition: Local-server was used on AC
• Description: Sometime the wireless user could not pass the 802.1x authentication because of reduplicate EAPOL packet.
Problem WLD22806
• First Found-in Version:CMW520-E2112
• Condition: None
Description: here is no record abo
Pr lem WLD22329
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 26
host on AC, it would send a reboot trap to iMC.
hot-backup was configured on two ACs and there were large er on them.
ections on ACs by command cut connection all l hot-backup to be disconnected.
on:CMW520-E2112
• Condition: SSID+VLAN was configured on AC, the ESS ports was configured to be
er wireless Portal users be forced to offline.
• First Found-in Version:CMW520-E2112
apconfig.txt l-forwarding mode.
• ocking the country-code on AC, the country-code could not er value but the default value.
Problem WLD22226
ion:CMW520-E2112
ser could not roam from HA to FA.
ion:CMW520-E2112
d statistic of GE port was incorrect.
Problem WLD22199
• Condition: None
• Description: After configure SNMP trap
Problem WLD22421
• First Found-in Version:CMW520-E2112
• Condition: Portal mount of Portal us
• Description: Cutting all of Portal connmight cause Porta
Problem WLD22569
• First Found-in Versi
Hybrid type and not in any VLAN
• Description: A wireless Portal user roamed in an AP and then roamed out the AP. This might cause the oth
Problem WLD22703
• Condition: None
• Description: The blank in the last byte of command map-configurationmight cause AC fail to send configuration to AP in Loca
Problem WLD22485
• on:CMW520-E2112 First Found-in Versi
• Condition: None
Description: After unlresume to the form
• First Found-in Vers
• Condition: Wireless 1x user connected with AC by CCMP, and then it changed its cipher-suite to TKIP.
• Description: The u
Problem WLD22261、WLD22205
• First Found-in Vers
• Condition: None
• Description Inboun
• First Found-in Version:CMW520-E2112
• Condition: None
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 27
AC has been running for long time, the counters of statistics of GE port might overflow..
rob
• P value in broadcast, multicast or unknown-unicast packet
• ckets with destination IP 255.255.255.255 could not be received by
L3 on AC.
rob
• the file uploading, if some AP downloading image file form AC, it
nnel between AP and AC down.
ess user connected with AC by some encrypt mode.
• Description: The wireless user cut connection and then re-connected. Sometime it seconds to re-connected with AC again.
• W520-E2112
pages, characters such as “-” in AP’s name were invalid characters during changing auto APs to persistent APs.
inputting ”-” in AP’s name , but the ld be lost after AC’s reboot again.
ob
on:CMW520-E2112
time a wireless user could not connect because of wrong key
Prob
on:CMW520-E2112
• Description: After
P lem WLD22394
• First Found-in Version:CMW520-E2112
Condition: None
• Description: DSCforwarded by AC was incorrect.
Problem WLD23062
• First Found-in Version:CMW520-E2112
Condition: None
• Description: IP pa
P lem WLD23214
• First Found-in Version:CMW520-E2112
Condition: Uploading file to AC by FTP.
• Description: Duringmight cause the established LWAPP tu
Problem WLD23187
• First Found-in Version:CMW520-E2112
• Condition: A Wirel
would take the wireless user about 30
Problem WLD23983
First Found-in Version:CM
• Condition: In WEB
• Description: No warning information if configuration wou
Pr lem WLD23989
• First Found-in Versi
• Condition: None.
• Description: SomeNonce during group key negotiation.
lem WLD23141
• First Found-in Versi
• Condition: None.
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 28
e AP connected with AC, AC would force to reboot the AP.
n:CMW520-E2112
• ss user could not pass re-authentication of 802.1x er authorization of the user could not be deleted from AC.
Problem W
• se of the EAP identifier mismatch.
ould not be identified by some versions of iMC, such as F5301and
• ttack on AC could not recognize the attacking packets with IP
address being “0.0.0.0”.
rob
• utbound QoS policy on WLAN-ESS port could not effect on the
icast packets.
• ult value of MAX SNMP PDU length was 1500 bytes on AC.
• Description: If some WLAN service-templates were bound with an AP in monitor mode, after th
Problem WLD23726
• First Found-in Version:CMW520-E2112
• Condition: None.
• Description: A null MAP file might cause the AP fail to get configuration form AC after it connected with AC.
Problem WLD23921
• First Found-in Versio
• Condition: None.
Description: Sometime the wirelebecause the form
LD23654
• First Found-in Version:CMW520-E2112
• Condition: None.
Description: Sometime the wireless user could not pass the 802.1x authentication becau
Problem WLD23623
• First Found-in Version:CMW520-E2112
• Condition: None.
• Description: AC cF5302.
Problem WLD23851
• First Found-in Version:CMW520-E2112
Condition: None.
• Description: Anti-a
P lem WLD23851
• First Found-in Version:CMW520-E2112
Condition: None.
• Description: The obroadcast or mult
Problem WLD24629
• First Found-in Version:CMW520-E2112
Condition: The defa
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 29
ngth were entified by
C.
m WLD24350
on:CMW520-E2112
be in capitals on AC.
Prob
on:CMW520-E2112
be in capitals on AC.
. Otherwise, after the AP
Prob
on:CMW520-E2112
v6 tunnel.
use of el data
• another interface might modify the
Resolved Problems in WX6103-CMW520-E211
Problem WLD21724
• TTP page of wireless users could not be redirected to Portal ges.
• roam to the other AC. Sometime its roaming would fail.
• Description: AC could not properly process the SNMP packets whose legreat than 1500 bytes. Sometime it might cause the AC could not be idiM
Proble
• First Found-in Versi
• Condition: The serial-id of AP profiles must
• Description: AP with lowercase letters in its serial-id could not connect with AC.
lem WLD24268
• First Found-in Versi
• Condition: The serial-id of AP profiles must
• Description: In the MAP file for AP, it must be end of RETURNconnected with AC, it could not get configuration of BSS port.
lem WLD23801
• First Found-in Versi
• Condition: An AP connected with AC by IP
• Description: Sometime wireless users could not connect by the AP becadifferent IPv6 addresses being used for tunnel control packets and tunnpackets on AP.
Problem WLD24066
• First Found-in Version:CMW520-E2112
• Condition: An ARP entry for some IP address has been learned on AC.
ARP packet received from Description: Illegalexisting ARP entry.
2
• First Found-in Version:CMW520-B2111P01
• Condition: None
Description: Sometime Hauthentication pa
Problem WLD22226
• First Found-in Version:CMW520-B2111P01
• Condition: Wireless user connected with AC by RSN+CCMP.
Description: It changed its encryption method to WPA+TKIP online and then began to
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 30
-in Version:CMW520-B2111P01
: Delete licenses on AC and reboot AC without save.
licenses was still in the display list of licenses information.
• m to the other AC because FA failed to ess to MAC-address table.
• nly in one VLAN on AC.
01
e time.
01
was failed and reboot again, the user tried to logout. The Portal logout page sent to user was not the bound page but the default page on AC.
Resolved Problems in WX6103-CMW520-B2111P
Problem WLD20026
• RP detection and
tions could
rsion:CMW520-B2111
Problem WLD22212
• First Found
• Condition
• Description: Deleted
Problem WLD22097
• First Found-in Version:CMW520-B2111P01
• Condition: Inter-AC mobile group was configured. Wireless user had connected HA.
Description: Sometime the user could not roaadd its MAC addr
Problem WLD21778
• First Found-in Version:CMW520-B2111P01
Condition: User-isolation was enabled o
• Description: Users in other VLANs were also isolated by user-isolation.
Problem WLD21794
• First Found-in Version:CMW520-B2111P
• Condition: 802.1x quiet was configured on AC.
• Description: Disable WLAN service template and then re-enable it. Sometime this might take som
Problem WLD21828
• First Found-in Version:CMW520-B2111P
• Condition: Portal dual-backup was used on AC. Portal authentication pages was bound with SSID. A Portal user was online and AC1 was its primary AC.
• Description: After AC1
01
• First Found-in Version:CMW520-B2111
Condition: AC was configured as DHCP server for wireless stations. ADHCP snooping were used on AC.
• Description: After stations had been connecting with AC for some time, stanot learn ARP of other devices any more.
Problem WLD20333
• First Found-in Ve
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 31
bound with
escription: Sometime WLAN service-template could not be enabled because of not nough resource in WLAN module.
0671
n: In configuration file, AP profiles were not sorted by AP profile name
Problem WLD20744
configured as PPPoE server.
.
-in Version:CMW520-B2111
t-backup was configured on two AC.
• Description: After VLAN interface on primary AC turn DOWN and UP, the Portal user
• d AC2 was
roblems in WX6103-CMW520-B2111/B2102
rst
ResolvB211
rst
• Condition: Large amount of APs were configured on AC. Each AP was more than six WLAN service-templates
• De
Problem WLD2
• First Found-in Version:CMW520-B2111
• Condition: Configure some AP profiles on AC.
• Descriptioascendingly.
• First Found-in Version:CMW520-B2111
• Condition: Portal authentication was used on AC. AC was
• Description: PPPoE users connecting AC need to pass Portal authentication
Problem WLD19631
• First Found
• Condition: Portal ho
might be forced to disconnect with AC.
Problem WLD21613
• First Found-in Version:CMW520-B2111
Condition: AC1 and AC2 were in hot-backup state. AC1 was master anslave. There constant broadcast traffic flow in wireless user’s VLAN.
• Description: After AC1 had been down, AC2 could not switch to master.
Resolved P
Fi release.
ed Problems in WX6103-CMW520-1
Fi release.
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 32
LAN ESS ports.
• ut Portal connection on
accounting-stop packet arrived at AC before the ACK_NTF_Logout ing two ACK_NTF_Logout packet would be discarded.
Reso vR210 P
Problem WLD18508
: Wireless stations connected AC with TKIP cipher-suite.
n: Sometime TKIP countermeasure errors occurred on AC. All of stations not go online for some time which could be
configured by command tkip-cm-time.
t Found-in Version:CMW520-R2109P04
ndition: Some APs were associated with AC. Reset the APs by WEB or command n ap all.
• Description: No trap information about tunnel down between APs and AC was sent to network management system.
Resolved Problems in WX6103-CMW520-R2109P08
Problem TCD02090
• First Found-in Version:CMW520-R2109P06
• Condition: Configure ARP rate-limit on W
• Description: The ARP rate-limit configuration did not work.
Resolved Problems in WX6103-CMW520-R2109P06
Problem TCD01909
• First Found-in Version:CMW520-R2109P01
Condition: User connected by Portal Authentication, then cAC.
• Description: If the packet, the follow
l ed Problems in WX6103-CMW520-9 05
• First Found-in Version:CMW520-R2109P03
• Condition
• Descriptiowould be kicked out, and they could
Problem WLD18105
• Firs
• Coreset wla
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 33
3-CMW520-R2109P04
9P03
• ition: User added licenses on AC.
• scription: The license keys input by use should be verified firstly.
Resolved Problems in WX6103-CMW520-
• Version:CMW520-R2109P01
• ber of VLAN1. After shutdo undo-ed to “UP” status.
• OWN”.
P
• 1
• Cs, shutdown the mast nd all of
• e still c ting with
Reso 2R210
elease only for Fit AP version compatibility.
3-CMW520-R210
relea
Resolved Problems in WX610
Problem WLD17239
• First Found-in Version:CMW520-R210
Cond
De rs
R2109P03 Problem WLD16508
First Found-in
Condition: Assign XGE port to be a memshotdown operations to XGE port, it chang
wn and
Description: But the status of VLAN 1 interface was still “D
roblem WLD17339
First Found-in Version:CMW520-R2109P0
Condition: In networks with N+1 hot-backup A er AC aAPs would connect with the backup AC
Description: When the master AC was recovered, the APs werthe backup AC.
onnec
lved Problems in WX6103-CMW5 0-9P01
R
Resolved Problems in WX6109
First se.
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 34
Related Documentation
Document title
New Feature Documentation Table 13 New Feature Documentation
Feature N A -
For information about other features, see Documentation Set.
Documentation Set Table 14 Documentation set
Document title Version H3C WX6103 Access Controller Installation Manual (V1.03)
H LSQM1WCMB0 Access Controller Module Installation Manual (V1.05) 3C
H3C LSBM1WCM2A0 Access Controller Module Installation Manual (V1.02)
10GE XFP Interface Module for WX6103 Access Controller Installation Guide (V1.01)
H3C WX Series Access Controllers User Manual 6W104
H3C WX Series Access Controllers Configuration Guides 6W105
H3C WX Series Access Controllers Command References 6W105
H3C WX Series Access Controllers Web-Based Configuration Guide 6W105
H3C WX6103 Access Controller Switch Interface Board Configuration Guide 6PW102
H3C WX6103 Access Controller Switch Interface Board Command Reference 6PW102
H3C WX6103 Access Controller Compliance and Safety Manual (V1.00)
H grade G3C uide 5PW100 Access Controller Modules Software Up
Obtaining Documentation
egory and model.
Software Upgrading
Overv
Take the following steps to get related documents from the H3C website at www.h3c.com. 1. Go to http://www.h3c.com/portal/Technical_Documents. 2. Choose the desired product cat
iew
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 35
UpgCAUTION:
rading software only when necessary and under the guidance of a technical support engineer
Files MaThe s the following three types of files:
• •
BootWa
m
• • are provides abundant man-machine interaction functions. It is used
ion for application program and boot system upgrade.
o the combination of the two sections. After the basic BootWare
naged by the Access Controller WX6103 manage
• BootWare program file
Application files
Configuration file
re Program File The BootWare program file is used by the access controller to boot the applications. The co plete BootWare program file consists of basic BootWare and extended BootWare.
Basic BootWare implements system initialization.
Extended BootWfor interface initializat
• Full BootWare refers tis started, you can load or upgrade the extended BootWare.
Do not power off the device when upgrading the BootWare; otherwise, the BootWare willWARNING:
possibly be damaged.
tion Files ApplicaThe e function. By default, three
• • • The
ypically, the default application file is written into the built-in CF card before the access
the system will choose one tsc
e llo
Main application file. The default name is main.bin, and the file type is M. It is the default application file to be loaded when the system starts.
WX6103 access controller supports the Dual Imagapplication files are defined for system boot:
Main application file (main file)
Backup application file (backup file)
Secure application file (secure file)
se files are stored in the built-in CF card, with an extension name of .bin.
Tcontroller is delivered.
If you have loaded the three application files into the CF card,of hese three files to boot the access controller, depending on the boot sequence de ribed below. For how to set the application file types, refer to section Maintaining Application and Configuration Files.
Th default names and types of the application files and their loading sequence are as fo ws:
•
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 36
kup application file. The default name is backup.bin, and the file type is B. If
• st
ot
he M, B, and S types can be used to boot the system, e N type (an application file other than the M, B, or S
, you can rename the application files M, B and N application files through the
you cannot change the type of the S
oting the system, you cannot change y changing the type of another type of
using the BootWare menu.
can exist in the CF card. For example, if an CF card, another file of type M or B cannot
B, the existing type M+B file changes to
n files are to store the configuration e default configuration file is written into
vered.
• Bacfailing to load the main application file, the system will try the backup file.
Secure application file. The default name is secure.bin, and the file type is S. If the system fails to load the backup application file, the secure application file is the lachoice. If it again fails to load the secure application file, the system will give a boot failure message.
e that: N
• Only the application files of twhile an application file of thtype) cannot.
• After the application program is loadedthrough the CLI or change the types of theBootWare menu or the CLI. However,application file.
• As the S application file is the last choice for boits type or obtain a secure application file bapplication file. You can only download it
• Only one file of the same type (M, B, or S)application file of type M+B exists in theexist. If the type of another file is changed toa file of type M.
Configuration Files With a file extension of .cfg, the configuratioinformation of the access controller. Typically, ththe built-in CF card before the access controller is deli
eed 64 characters (including the drive
the drive name is cfa0:/, the maximum length
CAUTION: • The length of a configuration file name must not exc
name and the string terminator). For example, ifof a file name is [ 64 – 1 – 4 ] = 59 characters.
• If the length of a file name exceeds 59 characters, error will occur in file operations on that file. It is recommended to keep the file name within
• There is a limitation on the length of file name thatis shorter than 30 characters, all the characters of the fhas or exceeds 30 characters, only the first 26 char
16 characters.
can be displayed in BootWare. If a file name ile name can be displayed; if a file name
ters of the file name can be displayed, followed by a tilde (~) and a serial number. The se l number identifies position in sequence of the file. For example, if some files, file A, file B and file C, have a file name longer than 30 characters, the name of file A will appear as the first 26 characters plus ~001, that of file B will appear as the first 26 characters plus ~002, and that of file C will appear as the first 26
acria
characters plus ~003.
Approaches for Software Maintenance
n files by BootWare using TFTP or FTP through an Ethernet port
• Upgrading the BootWare and application files using the Xmodem protocol through a serial port
• Upgrading applicatio
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 37
e application and configuration files by CLI using
e system program.
• Uploading and downloading thTFTP/FTP
NOTE: • The BootWare program is upgraded together with the host software version. That is, th
automatically upgrades the BootWare program when you upgrade the host software
• Before upgrading the software of your access controller, check the current BootWare version rade. For
ware andand application program version to make sure that the correct file is used for the upgthe association between the host software version and BootWare version, refer to HardSoftware Compatibility Matrix in Release Notes.
Softw
are Upgrade Flow Figure 1 Software upgrade flowchart
BooBootW
d with the
tWare Menus are Main Menu
Upon access controller power-on or reboot, the console terminal connecteaccess controller first displays the following information:
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 38
*************************************************
*
BootWare, Version 1.13 *
*
**************************************************************************
boot menu...
nless
System start booting...
Then, the following information appears: Booting Normal Extend BootWare....
The Extend BootWare is self-decompressing.................
Done!
*************************
*
* H3C WCMB
*
Copyright (c) 2004-2009 Hangzhou H3C Technologies Co., Ltd.
Compiled Date : Feb 11 2009
CPU Type : BCM1125H
CPU L1 Cache : 32KB
CPU Clock Speed : 600MHz
Memory Type : DDR SDRAM
Memory Size : 1024MB
Memory Speed : 166MHz
BootWare Size : 512KB
cfa0 Size : 261MB
CPLD Version : 008
PCB Version : Ver.C
BootWare Validating...
Press Ctrl+B to enter extended
NOTE: The extended boot menu is referred to as BootWare main menu in this manual uotherwise stated.
At the prompt above, press Ctrl+B. The system prompts you to enter the BootWare
d is null). If alted and
tem enters
======<EXTEND-BOOTWARE MENU>=======================
|<4> File Control |
password: Please input BootWare password:
You have three chances to enter the BootWare password (the initial passworyou fail to enter the correct password three times in a row, the system will be hyou can only restart the system. After you provide the correct password, the systhe BootWare main menu: Note: The current operating device is cfa0
Enter < Storage Device Operation > to select device.
=======================
|<1> Boot System |
|<2> Enter Serial SubMenu |
|<3> Enter Ethernet SubMenu |
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 39
=================================================
BootW
ate and so
ion File |
|
|<4> Update Secure Application File |
ystem
============================<Enter Ethernet SubMenu>======================
|
Run |
|
xit To Main Menu |
|<5> Modify BootWare Password |
|<6> Skip Current System Configuration |
|<7> BootWare Operation Menu |
|<8> Clear Super Password |
|<9> Storage Device Operation |
|<0> Reboot |
=========================
Enter your choice(0-9):
are Submenus Serial interface submenu
You can upgrade the application program, change the serial interface baud ron through this submenu.
Select 2 in the BootWare main menu to enter the serial interface submenu: =============================<Enter Serial SubMenu>======================
|Note:the operating device is cfa0 |
|<1> Download Application Program To SDRAM And Run |
|<2> Update Main Applicat
|<3> Update Backup Application File
|<5> Modify Serial Interface Parameter |
|<0> Exit To Main Menu |
==========================================================================
Enter your choice(0-5):
Ethernet interface submenu
Select 3 in the BootWare main menu to enter the Ethernet interface submenu. The sdisplays:
|Note:the operating device is cfa0
|<1> Download Application Program To SDRAM And
|<2> Update Main Application File
|<3> Update Backup Application File |
|<4> Update Secure Application File |
|<5> Modify Ethernet Parameter |
|<0> E
|<Ensure The Parameter Be Modified Before Downloading!> |
==========================================================================
Enter your choice(0-5):
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 40
t 4 in the BootWare main menu to enter the file control submenu. You can view the tion file types, rename the files, and delete the files through this submenu.
|No
|<1> Display All File(s) |
|<3
|<0> Exit To Main Menu |
are Operation Menu>======================
|
enu:
Device |
====================================================
Upg
le transfer protocol that is widely used due to its simplicity and good s of data packets
(128 bytes and 1 KB), two check methods (checksum and CRC), and error packet retransmission mechanism (generally the maximum number of retransmission attempts is ten).
File control submenu
Selecapplica=================================<File CONTROL>===========================
te:the operating device is cfa0 |
|<2> Set Application File type |
> Delete File |
==========================================================================
Enter your choice(0-3):
BootWare operation submenu
Select 7 in the BootWare main menu to enter the BootWare operation submenu: ===========================<BootW
|Note:the operating device is cfa0
|<1> Backup Full BootWare |
|<2> Restore Full BootWare |
|<3> Update BootWare By Serial |
|<4> Update BootWare By Ethernet |
|<0> Exit To Main Menu |
==========================================================================
Enter your choice(0-4):
Storage device operation submenu
Select 9 in the BootWare main menu to enter the storage device operation subm================================<DEVICE CONTROL>==========================
|<1> Display All Available Nonvolatile Storage Device(s) |
|<2> Set The Operating Device |
|<3> Set The Default Boot
|<0> Exit To Main Menu |
======================
Enter your choice(0-3):
rading the BootWare To upgrade the BootWare through a serial port, use the Xmodem protocol.
Xmodem is a fiperformance. Xmodem transfers files via serial ports. It supports two type
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 41
mpleted by the cooperation of a receiving The receiving program sends a negotiation character
After the negotiation, the sending program starts to send ing a complete packet, the receiving program checks the
d.
e receiving program sends an ACK character and the to send the next packet.
If the check fails, the rec iving program sends a NAK character and the sending program retransmits the packet.
raded together with the Comware application version. When you cation program, the system automatically checks whether the
are application and upgrades the
ller, check the current BootWare version the correct file is used for the upgrade. For ersion and the BootWare version, refer to
Release Notes.
The Xmodem transmission procedure is coprogram and a sending program.to negotiate a check method.data packets. Upon receivpacket using the agreed metho
• If the check succeeds, thsending program proceeds
• e
NOTE: • The BootWare program is upg
upgrade the Comware applicurrent BootWare version is compliant with the ComwBootWare version if needed.
• Before upgrading the software of your access controand Comware application version to make sure thatthe association between the Comware application vHardware and Software Compatibility Matrix in
Modifying Serial Communication Parameters Sometimes, we need a high serial port baud rate baud rate to ensure the transmission reliability.serial communication baud rate.
Follow these steps to change the serial communica
Enter the BootWare main menu and select 2 to enselect 5 in the submenu to modify the baud rate. T=================================<BAUDRATE SET>===========================
|Note:'*'indicates the current baudrate |
| Change The HyperTerminal's Baudrate Accordingly |
|---------------------------<Baudrate Avaliable>------------------------- |
|<1> 9600(Default)* |
|<2> 19200 |
to save the upgrade time, or a lower This section introduces how to adjust the
tion baud rate:
Step1 ter the serial interface submenu. Then, he system displays the following:
<3> 38400 |
|
|
|<0> Exit |
==========================================================================
Step2 te. For example, select 5 for 115200 bps. The following
to the
|
|<4> 57600
|<5> 115200
Enter your choice(0-5):
Select an appropriate baud rainformation appears: Baudrate has been changed to 115200 bps.
Please change the terminal's baudrate to 115200 bps, press ENTER when ready.
Now that the serial interface baud rate of the access controller has been changed115,200 bps while that of the terminal is still 9,600 bps, the access controller and
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 42
,200 bps in
Step3
terminal cannot communicate with each other. Change the baud rate to 115HyperTerminal.
Disconnect the terminal connection in HyperTerminal, as shown below:
Figure 2 Disconnect the terminal connection
Step4 File > Properties. In the Properties dialog box, click Configure… and select 115,200 Choosein the Bits per second drop-down list box.
Figure 3 Modify the baud rate
Step5 Select Call > Call to reestablish the connection.
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 43
Figure 4 Reconnect the call
Step6 t baud
ation File |
|
|
changed baud rate, timely change the baud rate back to re the normal display on the console screen when the
Then, press Enter in the serial interface submenu. The system prompts the currenrate and returns to the parent menu. ==============================<Enter Serial SubMenu>======================
|Note:the operating device is cfa0 |
|<1> Download Application Program To SDRAM And Run |
|<2> Update Main Application File |
|<3> Update Backup Application File |
|<4> Update Secure Applic
|<5> Modify Serial Interface Parameter
|<0> Exit To Main Menu
==========================================================================
Enter your choice(0-5):
NOTE: After downloading files with a9,600 bps in HyperTerminal to ensusystem boots or reboots.
Upgrading the BootWare Through the Management Ether
t interface:
Step1 o enter tWare
Step2 thernet
|
net Interface Follow these steps to upgrade the BootWare through the management Etherne
Enter the BootWare main menu (refer to section BootWare Menus) and select 7 tthe BootWare operation submenu. For details about this menu, refer to section Boooperation submenu.
Select 4 in the BootWare operation submenu to enter the BootWare operation Einterface submenu: =====================<BOOTWARE OPERATION ETHERNET SUB-MENU>===============
|<1> Update Full BootWare
|<2> Update Extend BootWare |
|<3> Update Basic BootWare |
|<4> Modify Ethernet Parameter |
|<0> Exit To Main Menu |
==========================================================================
Enter your choice(0-4):
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 44
Step3 mpts you
revious field. |
Select 4 in the BootWare operation Ethernet interface submenu. The system proto modify the network parameters. ============================<ETHERNET PARAMETER SET>======================
|Note: '.' = Clear field. |
| '-' = Go to p
| Ctrl+D = Quit. |
==========================================================================
Protocol (FTP or TFTP) :tftp
Load File Name :wx6103.bin
Target File Name :wx6103.bin
Server IP Address :192.168.0.179
Local IP Address :192.168.0.125
Gateway IP Address :192.168.0.1
NOTE: The load file name and target file name must not exceed 50 bytes.
After modification of the parameters, the system display returns to the BootWare
ARE OPERATION ETHERNET SUB-MENU>===============
|<1> Update Full BootWare |
|<2> Update Extend BootWare |
|
program at the following prompts:
.............Done!
ace submenu.
operation Ethernet interface submenu. =====================<BOOTW
|<3> Update Basic BootWare |
|<4> Modify Ethernet Parameter |
|<0> Exit To Main Menu
==========================================================================
Enter your choice(0-4):
Step4 Select 1 in the BootWare operation Ethernet interface submenu.
Update the BootWareLoading...................................................................
..........................................................................
.........................................................Done!
20710792 bytes downloaded!
Updating Basic BootWare? [Y/N]Y
Updating Basic BootWare................Done!
Updating Extend BootWare? [Y/N]Y
Updating Extend BootWare.
After download of the BootWare program file, the system display returns to the BootWare operation Ethernet interf===================<BOOTWARE OPERATION ETHERNET SUB-MENU>=================
|<1> Update Full BootWare |
|<2> Update Extend BootWare |
|<3> Update Basic BootWare |
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 45
Step5 tWare
|
otWare By Ethernet |
|
Step6 enu:
|
=====
Step7
Upgrading the BootWare Through a Serial Connection
Step1 o enter BootWare
l bmenu:
U>================
|
Basic BootWare |
|<4> Modify Ethernet Parameter |
|<0> Exit To Main Menu |
==========================================================================
Enter your choice(0-4):
Select 0 in the BootWare operation Ethernet interface submenu to enter the Boooperation submenu: =========================<BootWare Operation Menu>========================
|Note:the operating device is cfa0 |
|<1> Backup Full BootWare
|<2> Restore Full BootWare |
|<3> Update BootWare By Serial |
|<4> Update Bo
|<0> Exit To Main Menu
==========================================================================
Enter your choice(0-4):
Select 0 in the BootWare operation submenu to enter the BootWare main subm===========================<EXTEND-BOOTWARE MENU>=========================
|<1> Boot System |
|<2> Enter Serial SubMenu |
|<3> Enter Ethernet SubMenu |
|<4> File Control |
|<5> Modify BootWare Password |
|<6> Skip Current System Configuration |
|<7> BootWare Operation Menu |
|<8> Clear Super Password |
|<9> Storage Device Operation |
|<0> Reboot
=====================================================================
Enter your choice(0-9): 0
Select 0 in the BootWare main menu to reboot the access controller.
Follow these steps to upgrade the BootWare through a serial connection:
Enter the BootWare main menu (refer to section BootWare Menus) and select 7 tmenu. For details about this menu, refer to section the BootWare operation sub
operation submenu.
Step2 Select 3 in the BootWare operation submenu to enter the BootWare operation seriainterface su======================<BOOTWARE OPERATION SERIAL SUB-MEN
|<1> Update Full BootWare
|<2> Update Extend BootWare |
|<3> Update
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 46
e Parameter |
Step3 menu. The system prompts you to
|-----------------------------<Baudrate Avaliable>-----------------------|
<1> 9600(Default)* |
|<3> 38400 |
|
Step4 fying Serial ays the following
|<2> 19200 |
<3> 38400 |
|
|
|
=========================================
Step5 peration serial interface submenu. IAL SUB-MENU>================
1> Update Full BootWare |
|
|<4> Modify Serial Interfac
|<0> Exit To Main Menu |
==========================================================================
Enter your choice(0-4):
Select 4 in the BootWare operation serial interface submodify the baud rate. =================================<BAUDRATE SET>===========================
|Note:'*'indicates the current baudrate |
| Change The HyperTerminal's Baudrate Accordingly |
| Press 'Enter' to exit with things untouched. |
|
|<2> 19200 |
|<4> 57600
|<5> 115200 |
|<0> Exit |
==========================================================================
Enter your choice(0-5):
Change the communication baud rate by referring to section “ModiCommunication Parameters”. After the modification, the system displinformation: Baudrate has been changed to 115200 bps.
Please change the terminal's baudrate to 115200 bps, press ENTER when ready.
The current baudrate is 115200 bps
=================================<BAUDRATE SET>===========================
|Note:'*'indicates the current baudrate |
| Change The HyperTerminal's Baudrate Accordingly |
|---------------------------<Baudrate Avaliable>-------------------------|
|<1> 9600(Default) |
|
|<4> 57600
|<5> 115200*
|<0> Exit
=================================
Enter your choice(0-5):
Select 0 to return to the BootWare o======================<BOOTWARE OPERATION SER
|<
|<2> Update Extend BootWare |
<3> Update Basic BootWare |
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 47
ify Serial Interface Parameter |
===
Enter your choice(0-4):
Step6 SelapPlease Start To Transfer File, Press <Ctrl+C> To Exit.
x
ialog box
|<4> Mod
|<0> Exit To Main Menu |
=======================================================================
ect 1 in the BootWare operation serial interface submenu. The following prompt pears:
Waiting ...CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
Step7 Select Transfer > Send file… in the HyperTerminal window. The following dialog boappears:
Figure 5 Send File d
Step8 from g dialog box appears:
Download the file using Xmodem
Click Browse… to select the application file to be downloaded, and select Xmodemthe Protocol drop-down list. Then click Send. The followin
Figure 6
Upon successful download, the system displays the following information:
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 48
.........Done!
..Done!
Step9 terminal from 115,200 bps back to 9,600 bps, and
rade.
Download successfully!
354944 bytes downloaded!
Updating Basic BootWare? [Y/N]Y
Updating Basic BootWare.......
Updating Extend BootWare? [Y/N]Y
Updating Extend BootWare............
Change the baud rate on the consolereboot the access controller.
NOTE: • The actual file name, size and path may differ from what are shown in the figure above. Before
upgrading the software of your access controller, check the current BootWare version and application program version to make sure that the correct file is used for the upg
• After you download files with a changed baud rate, timely change the baud rate back to 9,600 bps in HyperTerminal to ensure the normal display on the console screen when the system boots or reboots.
Con
Step1 nu, refer to section BootWare Submenus.
ation Parameters.
Step3 wing prompt appears:
Step4 in HyperTerminal. The procedure for upgrading an he BootWare. For details, refer to section
Serial Connection.
NOTE: size of an application program is typically over 10 MB. Even at the baud rate of
an application program through an Ethernet interface.
Upgrading Applications Through a Serial nection The procedure is used to upgrade the three types of application files. This section describes how to upgrade the main application file.
Follow these steps to upgrade the main application file:
Select 2 in the BootWare main menu to enter the serial interface submenu. For details about this me
Step2 To improve the upgrading speed, first modify the serial interface baud rate. For details, refer to section Modifying Serial Communic
Select 2 in the serial interface submenu. The folloPlease Start To Transfer File, Press <Ctrl+C> To Exit.
Waiting ...CCCCCCCCCC
Select and send the application fileapplication file is the same as upgrading tUpgrading the BootWare Through a
The115,200 bps, the upgrade takes about 30 minutes. Therefore, you are recommended toupgrade
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 49
Upgrading Applications through an Ethernet Inter
t interface submenu.
Conf
r IP Address :192.168.0.179
e
face Select 3 in the BootWare main menu to enter the Ethernet interface submenu. For details about this submenu, refer to section Etherne
iguring Ethernet Interface Parameters Before upgrading an application program through an Ethernet interface, you need toconfigure the Ethernet interface of the access controller, as follows.
Select 3 in the BootWare main menu to enter the Ethernet interface submenu. Then, select5 to enter the Ethernet interface configuration submenu: ============================<ETHERNET PARAMETER SET>======================
|Note: '.' = Clear field. |
| '-' = Go to previous field. |
| Ctrl+D = Quit. |
==========================================================================
Protocol (FTP or TFTP) :tftp
Load File Name :wx6103.bin
Target File Name :wx6103.bin
Serve
Local IP Address :192.168.0.1
Gateway IP Address :192.168.0.10
NOTE: • When configuring a parameter, you can enter a new value directly, or press Enter to accept th
default value that follows a colon. Type . to clear the current input, - to return to the prevparameter fie
ious ld, and Ctrl+D to quit from the parameter configuration interface.
nt rade.
• The WX6103 access controller supports only the 10/100/1000Base-TX out-of-band managemeEthernet interface for application upg
Upgrading Applications Through the Management Ethernet Interface
for file transfer between sfer service. TFTP provides
ess authorization and ethod to implement
n through the management Ethernet interface:
anagement
The Trivial File Transfer Protocol (TFTP) is a TCP/IP protocol usedclient and server. It provides a simple and low-overhead file tranunreliable data transfer over UDP and does not provide any accauthentication mechanism. It employs the timeout retransmission mbest-effort delivery of data. Compared with FTP, TFTP has a much smaller software size.
Follow these steps to upgrade an applicatio
Step1 Set up a software upgrade environment. Connect the 10/100/1000Base-TX minterface to a PC with an Ethernet cable.
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 50
Figure 7 Set up a software upgrade environment
Step2 Run TFTP Server on the PC, and set the path of the application file to be downloaded.
NOTE: The TFTP server software is not pro ded with the WX6103 access controller. You must make sure that it is available by yourself.
vi
Step3 Modify the Ethernet interface parameters. For details, refer to section Configuring Ethernet
Step4
enu. The following information appears: .................
File 03.bin..........................................................
...................................................................................................................................................
.................................................................................................
.........................................................................................................................................................................................
.......................................................................................................................................
...................................................................................
.................................................................................................................................................................
.......................Do
Step5 Sele enu.
Step6 cess controller.
Interface Parameters.
Select 3 in the BootWare main menu to enter the Ethernet interface submenu. The following example shows how to upgrade the main application file. Select 2 in the Ethernet interface submLoading.....................................................................................................................................................................................Done!
20710792 bytes downloaded!
Updating cfa0:/wx61
.....................
..
.............................................................
............................................................
............................................................
..............................................................
..
..................................
..................................
..
.................................
..
..
.......
............................................................ne!
ct 0 to return to the BootWare main m
Select 1 in the BootWare main menu to reboot the ac
file in the CF card, the system e Y, the existing file will be
CAUTION: • If the downloaded file has the same file name with an existing
prompts The file is exist, will you recover it? [Y/N]. If you choosoverwritten.
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 51
s available in the CF card. In case of insufficient space, the s
file of the same type. In this example, the lication file of the type M and becomes
on file types, refer to section Application Files.
• Make sure that sufficient space iystem will give a prompt message.
• The new application file directly replaces the existingdownloaded file wx6103.bin replaces the existing appthe only main application file.
• For details about the applicati
Maintaining the Application and Configuration Files Through the CLI
Maintaining the Access Controller Through TFTP Usin TFTP client and a file server as the TFTP server, you
the same file server, to upload the r or
Se
Step1 t by referring to section 0“Upgrading Applications Through the Management Ethernet Interface”.
After the access controller is normally started, you can back up and restore the application and configure files through the CLI.
g the WX6103 access controller as acan use commands on the console terminal, which can be
configuration and application files from the access controller to the file servedownload the files from the file server to the access controller.
tting up a configuration environment
up a network environmentSe
Figure 8 Set up an environment for software maintenance through the CLI
Step2
Step3
the
lication and configuration files
wing operations on the console terminal:
Step1 View the files in the current file system with the dir command. <H3C>dir
Directory of cfa0:/
0 -rw- 617 Jul 26 2007 08:22:56 startup.cfg
1 -rw- 10021148 Jul 28 2035 10:35:38 wx6103.bin
Run TFTP Server on the file server and set the file path.
Configure the IP addresses for both sides, which must be on the same subnet. For example, set the IP address of the TFTP server to 192.168.0.1, and that of the access controller’s management Ethernet interface to 192.168.0.2. Then use ping to verifynetwork connectivity.
Backing up and restoring the app
After setting up the environment, perform the follo
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 52
<H3C>
Step2 the file backup or restoration (download) operation.
the TFTP
.cfg from the TFTP server to the access controller, do the following: get config.cfg statup.cfg
oading file from remote tftp server, please wait...\
in 0 second(s)
ready exists on the access controller, the system will ask you bort.
2 -rw- 356124 Jul 27 2007 09:23:54 bootware.app
247808 KB total (237996 KB free)
File system type of cfa0: FAT32
Perform
• To backup startup.cfg on the access controller by saving it as config.bak on server, use the following command:
<H3C>tftp 192.168.0.1 put startup.cfg config.bak
File will be transferred in binary mode
Sending file to remote TFTP server. Please wait... \
TFTP: 617 bytes sent in 0 second(s).
File uploaded successfully.
• To download config<H3C>tftp 192.168.0.1
The file statu.cfg exists. Overwrite it?[Y/N]:y
Verifying server file...
Deleting the old file, please wait...
File will be transferred in binary mode
Downl
TFTP: 617 bytes received
File downloaded successfully.
If a file with the same name alwhether to replace the existing file. Enter Y to replace it, or N to a
ons are performed in user view.
e ffect
ted. Likewise, you can update the main application file by he server and replacing the existing main application
CAUTION: • When you back up a file to the server and if a file with the same name already exists on the
aced. server, the existing file will be repl
• The above-mentioned operati
• The backup configuration file can be modified by using a text editor. You can update thsystem configuration by downloading a modified configuration file. Your update takes eafter the access controller is restar
ddownloa ing a new application file from tfile on the access controller.
Maintaining the Access Controller Through FTP
(FTP) is an application layer protocol in the TCP/IP suite. It is mainly tion-oriented
The access controller as the FTP server
File Transfer Protocolused for file transfer between remote hosts. FTP provides a reliable, connecdata transfer service over TCP.
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 53
he access controller is FTP Server. Using this feature, the n FTP client to log in to
ation on your PC. The FTP client er. You must make sure that it is
ction describes how to maintain the access controller Windows XP.
llo ugh FTP with the
Step1 work environment, as shown below:
maintenance environment (AC as FTP server)
The FTP service provided by taccess controller serves as the FTP server. You can use your PC as athe access controller for file operations.
Before using FTP, you need to install the FTP client applicsoftware is not provided with the WX6103 access controllavailable by yourself. This sesoftware using the FTP client application that comes with Microsoft
Fo w these steps to maintain the software of your access controller throaccess controller as the FTP server:
Set up a net
Figure 9 Set up a software
Configure the IP addresses Step2 for both sides, which must be on the same subnet. For ent to 192.168.0.1, and that of the access
rface to 192.168.0.2. Then use ping to verify the
Step3
n and authorization and enable FTP. The FTP server en a remote FTP client sends a request to the FTP server,
accordingly and returns the execution result to the to enable the FTP service:
Start FTP server
ser account guest
FTP
r user
Step5 ntroller
TP n the PC.
dow, and enter ftp at the DOS prompt. gs\Administrator>ftp
//The system prompt changed to ftp>
//Connect to the access controller
//Enter the username guest
example, set the IP address of the FTP clicontroller’s management Ethernet intenetwork connectivity.
Enable FTP service.
Configure FTP server authenticatiosupports multi-client access. Whthe FTP server executes an action client. Use the following command [H3C]ftp server enable
%
Step4 Add an authorized FTP username and password. [H3C]local-user guest Create u
[H3C-luser- guest]service-type ftp //Set user type to
[H3C-luser- guest]password simple 123456 //Set password foguest
Maintain the access co
After enabling the FTP service and configuring the username and password, start the Fclient application o
Open a DOS prompt winC:\Documents and Settin
ftp>
ftp> open 192.168.0.2
Connected to 192.168.0.2.
220 FTP service ready.
User (192.168.0.2:(none)): guest
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 54
he password 123456
r logged in. //Successfully connected to the
Step6
server, do the following: transfer mode to binary
hange the local path
onnection for main.bin.
/sec.
to the access
200 Port command okay.
p: 14323376 bytes sent in 8.29Seconds 1727.37Kbytes/sec.
the access
Step1
331 Password required for guest
Password: Enter t
230 Useserver
Maintain the access controller software.
• To backup main.bin on the access controller to theftp> binary //Set the
200 Type set to I.
ftp> lcd c:\temp //C
Local directory now C:\temp.
ftp> get main.bin main.bin //Backup to PC
200 Port command okay.
150 Opening BINARY mode data c
226 Transfer complete.
ftp: 14323376 bytes received in 16.81Seconds 851.87Kbytes
• To restore the backup file to the access controller, do the following: ftp> put main.bin main.bin //Downloadcontroller
150 Opening BINARY mode data connection for main.bin.
226 Transfer complete.
ft
ftp> quit //Quit FTP
221 Server closing.
The access controller as an FTP client
You can also maintain the file system of your access controller through FTP with controller as an FTP client.
Set up a maintenance environment.
Figure 10 Set up a software maintenance environment (AC as FTP client)
Step2
Step3 r ss
ify the
Run the FTP server program on the PC, set the file path, and set the username and password for the access controller.
Configure the IP addresses for both sides, which must be on the same subnet. Foexample, set the IP address of the FTP server to 192.168.0.1, and that of the accecontroller’s management Ethernet interface to 192.168.0.2. Then use ping to vernetwork connectivity.
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 55
Step4 t of the
et on the
//Enter the password
Step5 r software.
in
transfer successful.
(s) sent in 15.974 second(s) 896.00Kbyte(s)/sec.
connection
Maintaining Application and Configuration Files
following
=================<File CONTROL>===========================
|
|
==========================================================================
Maintain the access controller using the terminal connected to the console poraccess controller. <H3C>ftp 192.168.0.1
Trying 192.168.0.1 ...
Press CTRL+K to abort
Connected to 192.168.0.1.
220 3Com 3CDaemon FTP Server Version 2.0
User(192.168.0.1:(none)):guest //Enter the username sserver
331 User name ok, need password
Password:
230 User logged in
[ftp]
Maintain the access controlle
Use the get and put commands to download and backup files. [ftp]get main.bin main.bin
cf:/main.bin has been existing. Overwrite it?[Y/N]:y
200 PORT command successful.
150 File status OK ; about to open data connection
226 Closing data connection; File transfer successful.
FTP: 14323376 byte(s) received in 69.256 second(s) 206.00K byte(s)/sec.
[ftp]put main.bin main.b
200 PORT command successful.
150 File status OK ; about to open data connection
226 Closing data connection; File
FTP: 14323376 byte
[ftp]quit
221 Service closing control
You can use the file control submenu to modify and display file types.
Select 4 in the BootWare main menu to enter the file control submenu. Theinformation appears: ================
|Note:the operating device is cfa0 |
|<1> Display All File(s)
|<2> Set Application File type |
|<3> Delete File |
|<0> Exit To Main Menu
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 56
ormation appears:
'N/A' = NOT ASSIGNED
==========================================================================
Type Name |
==========================================================================
application file type
Step1 following information appears: = BACKUP 'S' = SECURE 'N/A' = NOT ASSIGNED
Type Name |
cfa0:/wx6103.bin |
|
===========================
Step2 le type:
==================================================================
| 1
|<2
|<4
<0> Exit |
================================================
hoice(0-4)
Step3 for +Main (set to M), 2 for –Main (remove the current M attribute), 3 for +Backup ), or 4 for –Backup (remove the current B attribute). For details about the file types,
To remove a file
following information appears:
ED
Time Type Name |
103.bin |
Enter your choice(0-3):
To view all files
Select 1 in the file control submenu. The following infDisplay all file(s) in cfa0:
'M' = MAIN 'B' = BACKUP 'S' = SECURE
|NO. Size(B) Time
|1 10021476 Jan/20/2034 10:12:36 M cfa0:/wx6103.bin |
|2 795 Jan/20/2006 11:58:50 N/A cfa0:/startup.cfg |
To set an
Select 2 in the file control submenu. The 'M' = MAIN 'B'
==========================================================================
|NO. Size(B) Time
|1 20710792 Jan/20/2034 10:12:36 M
|0 Exit
===============================================
Enter file No:
Enter the file number at the prompt above. In this example, type 1 for wx6103.bin, and press Enter. The system prompts you to specify a new fiModify the file attribute:
========
< > +Main |
> -Main |
|<3> +Backup |
> -Backup |
|
==========================
Enter your c
Select 1(set to Brefer to section Application Files.
Step1 Select 3 in the file control submenu. The Deleting the file in cfa0:
'M' = MAIN 'B' = BACKUP 'S' = SECURE 'N/A' = NOT ASSIGN
==========================================================================
|NO. Size(B)
|1 10021476 Jan/20/2034 10:12:36 M cfa0:/wx6
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 57
rtup.cfg |
|
==========================================================================
le No:
Step2 Typ
Step3 t following message appears, indicating the file was successfully deleted.
Dealing with Password Loss
User et a new
n system
The
Step2 h
Step3
This ord authentication is used for console port login, the n text.
After reboot, the system runs with the initial default configuration, while the original the original configuration, use the display
ation file, and then copy and run it.
display current-configuration command iguration. If you use the set authentication password sword, the password will be stored in cipher text.
|2 795 Jan/20/2006 11:58:50 N/A cfa0:/sta
|0 Exit
Enter fi
e a file number and press Enter. The system asks you to confirm your operation. The file you selected is cfa0:/startup.cfg,Delete it? [Y/N]
er Y for confirmation. TheEn
Deleting..........Done!
To return to the main menu
Select 0 to return to the BootWare main menu.
This section describes how to deal with password loss.
Password Loss If you forget your user password, the system will refuse your login. In this case, suser password by following the steps below.
Step1 Enter the BootWare main menu and select 6 to bypass the current configuration istartup.
following information appears: Flag Set Success.
W en the BootWare main menu appears again, select 0 to restart the system. System starts booting ...
Set a new user password in system view. [H3C]user-interface con 0
[H3C-ui-console0]authentication-mode password
[H3C-ui-console0]set authentication password simple 123456
information indicates that passwpassword is set to 123456, and it is stored in plai
NOTE: •
configuration file is still kept in the CF card. To restoresaved-configuration command to locate the configur
• If the password is stored in plain text, you can use the to view the password in the current confcipher 123456 command to set your pas
Step4 Save your new password. [H3C] save
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 58
NOTE: After modifying the user password, use the save command to save it.
BootWare Password Loss Contact your local dealer if you forget the BootWare password. The technical support staff will help you log in to the access controller and set a new password.
To change the BootWare password, enter the BootWare main menu, select 5, and follow the prompts: please input old password:
Please input new password:
Please input new password again:
Password Set Successfully.
NOTE: • Once you enter a wrong old password or different new passwords, the password modification
operation fails and the system exits this operation.
• The BootWare password can consist of a maximum of 32 printable characters, including letters, numerals, and symbols.
Super Password Loss The super password enables you to switch between four super levels. If you forget the super password, you will be unable to perform some higher privilege operations.
Follow these steps to bypass the super password:
Step1 Select 8 in the BootWare main menu.
Step2 Exit the menu and reboot the access controller. You will directly enter system view after the access controller restarts.
This setting works only once. When the access controller is restarted for a second time, the super password is restored.
Backing Up and Restoring the BootWare Step1 Select 7 in the BootWare main menu to enter the BootWare operation submenu. For
details about this submenu, refer to section BootWare operation submenu.
Step2 Back up or restore the BootWare.
• To back up the entire BootWare to the CF card, select 1 in the BootWare main menu and follow the prompts.
Will you backup the Basic BootWare? [Y/N]Y
Begin to backup the Basic BootWare...................Done!
Will you backup the Extend BootWare? [Y/N]Y
Begin to backup the Extend BootWare...................Done!
• To restore the backup BootWare from the CF card, select 2 in the BootWare main menu and follow the prompts.
WX6103-CMW520-R2115P15 Release Notes
Hangzhou H3C Technologies Co., Ltd. 59
Will you restore the Basic BootWare? [Y/N]Y
Begin to restore Normal Basic BootWare.................Done!
Will you restore the Extend BootWare? [Y/N]Y.................Done!
Notes for upgrading FIT AP Interim version for WA2100
The interim version for WA2100 is named wa2100_update.bin. If the file does not exist on AC, it must be uploaded to AC manually and its name must be “wa2100_update.bin”.
Two versions of WA2100 should be saved on AC, one is the interim version named “wa2100_update.bin”, the other is the version named “wa2100.bin” which is compatible with AC’s version. If a WA2100, whose version is previous to R1106P03, tries to connect with AC, it will download the interim version firstly, and then download the file named wa2100.bin.
Interim version for WA2200 The interim version for WA2200 is named wa2200_update.bin. If the file does not exist on AC, it must be uploaded to AC manually and its name must be “wa2200_update.bin”.
Two versions of WA2200 should be saved on AC, one is the interim version named “wa2200_update.bin”, the other is the version named “wa2200_fit.bin” which is compatible with AC’s version. If a WA2200 FIT AP, whose version is previous to R1109P01, tries to connect with AC, it will download the interim version firstly, and then download the file named wa2200_fit.bin.