WEST VIRGINIA ECONOMIC DEVELOPMENT AUTHORITY REQUEST FOR QUALIFICATIONS FOR DEMOLITION AND REMEDIATION OF THE FORMER CENTURY ALUMINUM PLANT LOCATED NEAR MILLWOOD, JACKSON COUNTY, WEST VIRGINIA ____________________________________ Date of Issue: February 2, 2022 Response Deadline: 3:00 PM (EST) Friday, February 25, 2022 Response Submission to: WV Economic Development Authority ATTN: Kris Warner, Executive Director 180 Association Drive Northgate Business Park Charleston, West Virginia 25311

Transcript of west virginia economic development

WEST VIRGINIA ECONOMIC DEVELOPMENT 

AUTHORITY 

 

REQUEST FOR QUALIFICATIONS  

FOR DEMOLITION AND REMEDIATION 

OF THE  

FORMER CENTURY ALUMINUM PLANT 

LOCATED NEAR 

MILLWOOD, JACKSON COUNTY, WEST VIRGINIA 

 

 

____________________________________ 

 

Date of Issue:   February 2, 2022  Response Deadline: 3:00 PM (EST) Friday, February 25, 2022 

Response Submission to:  WV Economic Development Authority ATTN:  Kris Warner, Executive Director 180 Association Drive Northgate Business Park Charleston, West Virginia 25311  

Request for Qualifications                      Environmental Remediation Services – Former Century Aluminum _____________________________________________________________________________________ 

 

WVEDA, 180 Association Drive, Northgate Business Park, Charleston, WV 25311                         2 | P a g e  

LEGAL NOTICE WEST VIRIGNIA ECONOMIC DEVELOPMENT AUTHORITY

REQUEST FOR QUALIFICATIONS FOR DEMOLITION AND REMEDIATION OF THE FORMER CENTURY ALUMINUM PLANT

MILLWOOD, JACKSON COUNTY, WEST VIRGINIA

The West Virginia Economic Development Authority (WVEDA) solicits Statements of Qualifications (SOQ) from demolition and remediation firms interested in performing all aspects of project management and professional services involved with the demolition, removal, remediation, and disposal associated with the former Century Aluminum Plant located near Millwood, Jackson County, West Virginia. The former aluminum plant is located between Millwood and Ravenswood, WV adjacent to the Ohio River. The demolition and remediation services are subject to terms and conditions set forth in detail in the Request for Qualifications (“RFQ”). Copies of the RFQ may be obtained at the above address, Monday through Friday between 9:00 AM and 3:00 PM (holidays excepted) or may downloaded from https://eda.wv.gov/about/Pages/Meeting-Minutes-&-Public-Information.aspx Procurement of said services shall be in accordance with 2 CFR 200.320 (d) (5) and West Virginia Code Chapter 5G. All firms interested in being considered for this project must submit a SOQ detailing qualifications, technical expertise, management and staffing capabilities and related prior experience. Respondents will be required to provide proof of insurance and policy limitations including workers’ compensation insurance, in the form of an insurance certificate. Additionally respondents will be required to provide proof of good standing with the State of West Virginia Tax Department. Respondents should demonstrate proof, in the form of a letter from a surety company, of the ability to obtain a payment and performance bond in the minimum amount of the contract amount. The object of the competitive process is to objectively identify qualified firms who will provide the highest quality of service. Accordingly, technical qualifications and experience will be weighed heavily. Selected respondents will be interviewed, and the WVEDA will rank the three most qualified respondents, who will then be asked to proceed under a request for proposal process to submit bids for the project. An original and five (5) copies of all requested information should be mailed or delivered to: West Virginia Economic Development Authority ATTN: Kris Warner, Executive Director 180 Association Drive, Northgate Business Park Charleston, West Virginia 25311 Responses must be received by 3:00 PM EST on Friday, February 25, 2022. Qualifications received after 3:00 pm will not be accepted. The proposals must be sealed and clearly marked “RFQ Response for Former Century Aluminum” in the lower left corner. Faxed or electronically‐mailed (emailed) submissions will not be accepted. The WVEDA will afford full opportunity for minority business enterprises to submit a SOQ in response to this invitation and will not discriminate against any interested firm or individual on the grounds of race, creed, color, sex, age, handicap or national origin in the contract award. The WVEDA reserves the right to accept or reject any and/or all proposals.

Request for Qualifications                      Environmental Remediation Services – Former Century Aluminum _____________________________________________________________________________________ 

 

WVEDA, 180 Association Drive, Northgate Business Park, Charleston, WV 25311                         3 | P a g e  

All questions regarding this RFQ shall be received in writing by email to the Executive Director of WVEDA, Kris Warner ([email protected]). A mandatory site visit will be held on Tuesday, February 15, 2022 starting at 9:00 A.M. Questions are due no later than Wednesday, February 23, 2022. Kris Warner Executive Director, West Virginia Economic Development Authority

Request for Qualifications                      Environmental Remediation Services – Former Century Aluminum _____________________________________________________________________________________ 

 

WVEDA, 180 Association Drive, Northgate Business Park, Charleston, WV 25311                         4 | P a g e  

REQUEST FOR QUALIFICATIONS

1.0 Project Overview and Background The West Virginia Economic Development Authority (WVEDA) owns approximately 2,200 acres of land that includes the site of the former Century Aluminum of West Virginia, Inc. (CAWV) plant near Millwood, Jackson County, West Virginia. The site is the location of the former Kaiser Aluminum plant that was established in 1954. The former aluminum plant is located between Millwood and Ravenswood, WV along Century Road and adjacent to the Ohio River. Refer to Appendix A – Site Maps for site maps showing the location of the site and the approximate property boundaries. The plant was idled by CAWV in 2009 and closed in 2015. The site was purchased by Applied Partners, Inc. in 2017. Applied Partners, Inc. planned to demolish the aluminum smelter and other site structures to facilitate redevelopment of the site. Demolition was started in late January 2017 and partially completed. WVEDA acquired the site via a deed in lieu of foreclosure in 2020. There are currently several structures that are partially demolished, some of which may contain Asbestos Containing Materials (ACM). In August 2021, WVEDA retained Greenbrier Environmental Group, Inc. (GEG) to visit the site, meet with the West Virginia Department of Environmental Protection (WVDEP) and review available regulatory files associated with the site. Refer to Appendix B – Environmental Regulatory Summary for a document prepared by GEG that summarizes the discussions with the WVDEP and known environmental regulatory issues associated with the site. The WVEDA solicits Statements of Qualifications (SOQ) from demolition and remediation firms interested in performing all aspects of demolition and environmental remediation of the former Century Aluminum Plant located near Millwood, Jackson County, West Virginia. The selected firm will work with the WVEDA to develop a scope of work that will include, but not be limited to, the following tasks:

Disposal of, recycling, or management of all existing demolition debris including abatement and management of ACM;

Demolition and/or decommissioning of structures, equipment, storage tanks, apparatus, piping, infrastructure present at the site;

Waste characterization and disposal/management; Remediation of the site to address all known environmental issues identified in the document

prepared by GEG and included as Appendix B; and, Site reclamation to facilitate redevelopment.

Environmental remediation must be completed in accordance with all applicable Federal, State, and local regulations. 2.0 Statement of Qualifications Submission Deadline

An original and five (5) copies of all requested information should be mailed or delivered to: West Virginia Economic Development Authority ATTN: Kris Warner, Executive Director 180 Association Drive, Northgate Business Park Charleston, West Virginia 25311 Responses must be received by 3:00 PM EST on Friday, February 25, 2022. Qualifications received after 3:00 pm will not be accepted. The proposals must be sealed and clearly marked “RFQ Response for Former

Request for Qualifications                      Environmental Remediation Services – Former Century Aluminum _____________________________________________________________________________________ 

 

WVEDA, 180 Association Drive, Northgate Business Park, Charleston, WV 25311                         5 | P a g e  

Century Aluminum” in the lower left corner. Faxed or electronically‐mailed (emailed) submissions will not be accepted.

3.0 Request for Qualifications Contact The contact regarding this RFQ process is WVEDA Executive Director, Kris Warner. Prospective applicants may make inquiries to obtain clarification of the requirements contained in this RFQ. All questions regarding this RFQ shall be received in writing by email to the Executive Director of WVEDA, Kris Warner ([email protected]). A mandatory site visit will be held on February 15, 2022 starting at 9:00 A.M. Questions are due no later than Wednesday, February 23, 2022. 4.0 Statement of Qualifications Format Proposals should be limited to 20 numbered pages. Please include a cover letter that identifies a contact person and all call information. The following format is not required but is encouraged to provide consistency between proposals, aiding in evaluation and comparison. If the format is modified, please include the following information at a minimum:

i. Project Approach: Describe your team’s approach to successfully delivering the project. Provide details on how each task will be completed. Include any recommendations for maximizing effectiveness and efficiency. ii. Relevant Project Experience: Provide a summary of your experience with similar projects, including location and client contact information. Specify the services provided, the office location from which the work was performed, and staff members’ responsibilities. Web links to recent plans and past work, if available, may be included in addition to project summaries. iii. Project Team: Provide an organizational chart identifying all staff assigned to the project, including any sub-contractors, defining roles, responsibilities, and task assignments of each member for the duration of the project. iv. Qualifications of Personnel: Provide relevant experience and qualifications of all personnel assigned to the project. v. Scope of Work: Provide an outline for keeping the project on schedule and within budget. Include projected workloads and staff availability, as well as a projected schedule for completion of significant milestones. vi. References: Provide contact information for at least three references for clients familiar with your work. vii. Insurance; Good Standing: Provide proof of insurance and policy limitations including workers’ compensation insurance, in the form of an insurance certificate. Provide proof of good standing with the State of West Virginia Tax Department. viii. Bonding Capacity: Provide proof, in the form of a letter from a surety company, of the ability to obtain a payment and performance bond in the minimum amount of the contract amount. 

5.0 Evaluation Criteria SOQs should address all aspects of the RFQ and clearly express an understanding of the requirements and qualifications to conduct these services in a thorough and efficient manner. SOQs will be evaluated by a committee appointed by the WVEDA. SOQs will be evaluated on the firm’s ability to meet the requirements of this RFQ. Some evaluation criteria, among other factors, will include:

I. Project approach and demonstrated understanding of the goals for the site; II. Creativity and vision for overall project;

Request for Qualifications                      Environmental Remediation Services – Former Century Aluminum _____________________________________________________________________________________ 

 

WVEDA, 180 Association Drive, Northgate Business Park, Charleston, WV 25311                         6 | P a g e  

III. Familiarity with and understanding the nature and challenges of the project; IV. Qualifications and availability of staff assigned to the project; V. Relevant project experience; VI. References.

Candidate firms may be asked to present their proposal to a committee appointed by the WVEDA before the final selection is made. Final selection and contracting will be subject to approval by the WVEDA Board of Directors.

6.0 Project Schedule It is anticipated that the firm will be able to accomplish all tasks and deliver a site that is ready for development within 18 months. 7.0 Administrative Information All proposals become the property of the WVEDA upon submission and will only be returned at the WVEDA’s option. Any restrictions on the use of the data contained within must be clearly stated in the SOQ itself. The cost of preparing, submitting and presenting a SOQ is the sole expense of the proposing firm. The WVEDA is not liable for any costs prior to issuance of a signed contract. The WVEDA reserves the right to reject any and all SOQs, to consider alternatives, to waive irregularities and to re-solicit a RFQ. The WVEDA reserves the right to cancel the RFQ in part or in its entirety. This solicitation of SOQs in no way obligates the WVEDA to award a contract. The WVEDA makes no guarantees to any proposing firm until such time the WVEDA approves the negotiated contract. The WVEDA will provide information and assistance in this project where available. Procurement of said services shall be in accordance with 2 CFR 200.320 (d) (5) and West Virginia Code Chapter 5G. The WVEDA will afford full opportunity for minority business enterprises to submit a SOQ in response to this invitation and will not discriminate against any interested firm or individual on the grounds of race, creed, color, sex, age, handicap or national origin in the contract award.

 

APPENDIX A

SITE MAPS

FORMER CENTURY ALUMINUM1325 CENTURY ROADMILLWOOD, WV 25262

SITE LOCATION MAPTITLE:

0 1,000 2,000500Feet

DJDRAWN BY:

CHECKED BY:

PROJECT NUMBER:

DATE:MF

APPROVED: REVISED:SW

DES: FIGURE NUMBER1

04/08/2014

12/07/2021

Docu

ment

Path:

C:\G

IS D

ATA\

WV_D

evelo

ment_

Auth\

Fig1_

Site_

Loca

tion_

Map.m

xd

±1 inch = 2,000 feet

EDA-2021-141

Service Layer Credits: Topographic map provided by ESRI's ArcGIS Online USA TopoMaps service (Copyright:© 2013 National Geographic Society, i-cubed)U.S.G.S. Topographic Map is 7.5 - minute "Ravenswood" quadrangle.

SITE LOCATIONLONG: -81.824192

LAT: 38.93649

← OHIO RIVER

TITLE:

0 400 800200Feet

DJDRAWN BY:

CHECKED BY:

PROJECT NUMBER:

DATE:MF

APPROVED: REVISED:

DES: FIGURE NUMBER

12/7/2021

EDA-2021-141

2

SITE BOUNDARY MAPFORMER CENTURY ALUMINUM

1325 CENTURY ROADMILLWOOD, WV 25262

LegendSite Boundary

Docu

ment

Path:

C:\G

IS D

ATA\

WV_D

evelo

ment_

Auth\

Fig2_

Site_

Vicini

ty_Ma

p.mxd

±1 inch = 817 feet

Tax Parcel18-06-0002-0002-0000

 

APPENDIX B

ENVIRONMENTAL REGULATORY SUMMARY

292 Oak Carriage Drive, Lewisburg, West Virginia 24901 917 Canyon Road, Morgantown, West Virginia 26508

www.greenbrierenv.com

December 8, 2021

West Virginia Economic Development Authority 180 Association Drive Northgate Business Park Charleston, West Virginia 25311

Attention: Kris Warner Executive Director

Subject: Site Visit, Regulatory Agency Meeting, and File Review Summary Former Century Aluminum Century Road Millwood, Jackson County, West Virginia

Dear Mr. Warner:

The purpose of this correspondence is to provide an overview of the environmental conditions at the site based on the site visit completed by Greenbrier Environmental Group, Inc. (GEG) on August 5, 2021, meeting with West Virginia Department of Environmental Protection (WVDEP) staff on October 15, 2021, and our review of available files.

Scope of Work

The following scope of work was completed by GEG.

Site Visit – August 5, 2021

GEG completed a site visit on August 5, 2021 to tour the site, meet with West Virginia Economic Development Authority (WVEDA) staff and WVDEP, and obtain information regarding the location and nature of the environmental issues at the site. A summary of the site visit was prepared by John Meeks with the WVDEP Office of Environmental Remediation (OER). The summary lists environmental issues observed and potential options to address each. Refer to Attachment I – WVDEP OER Site Visit Summary for a copy of the summary letter prepared by Mr. Meeks. Photographs taken during the site visit are included to this correspondence as Attachment II – Photographic Documentation.

Regulatory Agency Meeting – October 15, 2021

GEG met with WVEDA staff and representatives from the WVDEP to discuss the known environmental issues at the site and potential short and long-term compliance and remediation options. The WVDEP recommended

Site Visit, Regulatory Agency Meeting, and File Review Summary Former Century Aluminum Century Road Millwood, Jackson County, West Virginia

Page 2

addressing compliance issues immediately and then remediation of the site. WVDEP also recommended that compliance and remediation of any areas that drain to the Ohio River should be dealt with first. The following WVDEP staff were present at the meeting on October 15, 2021:

Jeffrey Cavender, Aboveground Storage Tank (AST)/Underground Storage Tank (UST) Section Joe Sizemore, Environmental Enforcement/Hazardous Waste John Meeks, OER Jesse Adkins, Division of Air Quality Jacob Rhodes, Asbestos Inspector-In-Training Jeff Hedgecock, Division of Air Quality/Asbestos John Killion, Hazardous Waste Inspector Supervisor Brad Wright, Water and Solid Waste Inspector Ryan Harbison, Waste Inspector

The following environmental issues were discussed:

AST Compliance WVDEP indicated the WVEDA needs to be listed as the owner of the ASTs at the site. The ASTs would need brought into compliance within 30 days after the transfer of ownership to WVEDA. The ASTs would need to be closed by August 1, 2023. There are Level I and Level II ASTs at the site, which means that a release from the ASTs has the potential to impact a downstream water intake or source water protection area. One leaking AST at the site was discussed and should be closed as soon as possible. WVDEP recommended the West Virginia Bureau for Risk Insurance Management (BRIM) for AST insurance.

Unsatisfactory Compliance Evaluation Inspection, WV/NPDES Permit Number WV0000779 WVDEP issued a Report of Compliance Evaluation Inspection for WV/NPDES Permit Number WV000079 on May 6, 2021. The report listed several unsatisfactory environmental conditions. Refer to Attachment III - Compliance Evaluation Inspection, WV/NPDES Permit Number WV0000779 (May 6, 2021) for a listing of the unsatisfactory environmental conditions that must be corrected at the site that were included in the Compliance Evaluation Report dated May 6, 2021. The WVDEP discussed the requirement to correct each unsatisfactory environmental condition.

Violation No. W21-18-001-RTH

WVDEP issued a Notice of Violation (NOV) for Violation No. W21-18-001-RTH on May 6, 2021. The NOV cited Applied Partners, Inc (WVEDA) for an unpermitted discharge from the roadbed constructed with contaminated demolition material located at the northern portion of the facility discharging into the Ohio River. Refer to Attachment IV – WVDEP Notice of Violations for a copy of the NOV for Violation No. W21-18-001-RTH dated May 6, 2021.

The WVDEP indicated that excavation and temporary covered storage of the contaminated material (cryolite) used to construct the roadway may be acceptable with coordination of the WVDEP.

Violation No. W21-18-002-RTH

WVDEP issued a NOV for Violation No. W21-18-002-RTH on May 6, 2021. The NOV cited Applied Partners, Inc (WVEDA) for the following violations of WV/NPDES Permit Number WV0000779:

Site Visit, Regulatory Agency Meeting, and File Review Summary Former Century Aluminum Century Road Millwood, Jackson County, West Virginia

Page 3

o Used mineral oil leaking from an AST located on the southeastern portion of the facility. The

leaking mineral oil was contaminating the soil within the mineral oil AST secondary containment area.

o Stained pavement and soil from previous spill adjacent to tote containing molasses. o Petroleum contaminated soil from previous spill adjacent 4,000-gallon diesel tank. o Tote containing used oil adjacent to the Carbon Press AST's leaking and contaminating the

adjacent soil. o Discharge associated from removed waste material from the demolition of the facility that had been

used to create a roadbed used for offloading pipe from train cars onto waiting trucks. The stormwater runoff from this area was discharging into the Ohio River creating an unpermitted Outfall.

The WVDEP indicated that excavation and temporary covered storage of the contaminated material (cryolite) used to construct the roadway may be acceptable with coordination of the WVDEP.

Refer to Attachment IV – WVDEP Notice of Violations for a copy of the NOV for Violation No. W21-18-002-RTH dated May 6, 2021.

Violation No. W21-18-003-RTH

WVDEP issued a NOV for Violation No. W21-18-003-RTH on May 6, 2021. The NOV cited Applied Partners, Inc (WVEDA) for exceeding the effluent limits at permitted Outfall 003 and 004. It was discussed that addressing the violations listed in Violation Number W21-18-002-RTH will likely reduce contaminant levels in the effluent samples. Refer to Attachment IV – WVDEP Notice of Violations for a copy of the NOV for Violation No. W21-18-003-RTH dated May 6, 2021.

Violation No. W21-18-004-RTH

WVDEP issued a NOV for Violation No. W21-18-004-RTH on May 6, 2021. The NOV cited Applied Partners, Inc (WVEDA) for drums containing material that have the potential to contaminate groundwater and required proper storage so that spills and leaks are contained. Addressing the violations includes several drums and other storage containers at the site that need to be characterized (hazardous versus non-hazardous) and properly disposed of. Refer to Attachment IV – WVDEP Notice of Violations for a copy of the NOV for Violation No. W21-18-004-RTH dated May 6, 2021.

Additional NOVs have been issued to the site, but were not discussed during the meeting with WVDEP on October 15, 2021.

Notice of Violation No. 2105-590

Applied Partners, Inc. was issued NOV# 1909-599 after a September 30, 2019 Focused Compliance Inspection. A follow-up inspection was completed on May 6, 2021. WVDEP noted that the mineral tanks at the site are continuing to leak the contents into the secondary containment. There was also no evidence that the containment was holding the material, as no pooling water or oil has been observed by inspectors during the inspections. Several other hazardous was violations were also noted. Refer to Attachment IV – WVDEP Notice of Violations for a copy of the NOV for NOV No. 2105-590 dated May 19, 2021.

Site Visit, Regulatory Agency Meeting, and File Review Summary Former Century Aluminum Century Road Millwood, Jackson County, West Virginia

Page 4

On-Site Waste Management

The WVDEP mentioned a ½-acre exemption for burying debris waste. The WVDEP recommended discussing the burying of fire brick with WVDEP’s Solid Waste Permitting Supervisor, John Lockhart, as a Class D landfill permit may be required. The potential of low-level radiation emanating from the fire brick was discussed, but an NOV has not been issued by the WVDEP for radiation exceedances. WVDEP recommended discussing the radiation concern with Michelle Cochran of the West Virginia Division of Health and Human Resources (DHHR). WVDEP agreed that permitting of an on-site hazardous waste landfill at the site to store cyrolite is an option, but they advised against it due to the permitting and long-term monitoring requirements.

Resource Conservation and Recovery Act (RCRA) Corrective Action WVDEP recommended discussing the status of the RCRA Corrective Action with the WVDEP Division of Water and Waste Management. On December 1, 2021, GEG contacted WVDEP OER to obtain a copy of the Environmental Covenant executed between Century Aluminum of West Virginia, Inc. and the WVDEP on December 2, 2016. The Environmental Covenant limits use of a portion of the property and is the result of RCRA Corrective Action at the site. Refer to Attachment V – Environmental Covenant (12/2/2016).

File Review

GEG submitted a Freedom of Information Act (FOIA) request to the WVDEP on October 4, 2021 to obtain all WVDEP files available for the site. The following responses were received by GEG from the WVDEP:

10/5/2021 – WVDEP Division of Air Quality responded by directing GEG to WVDEP’s electronic document management system located at https://documents.dep.wv.gov/appxtender. The latest WVDEP Division of Air Quality Inspection Report is dated August 1, 2018. The inspection Report is included as Attachment VI – WVDEP Division of Air Quality Inspection Report.

10/5/2021 – WVDEP Division of Air Quality/Asbestos responded by directing GEG to the WVDEP Electronic Submittal System (ESS) and https://dep.wv.gov/daq/CandE/Pages/AsbestosRemovalandDemolition.aspx to obtain demolition notifications. GEG downloaded the demolition notifications associated with the site on November 8, 2021. Refer to Attachment VII – WVDEP Asbestos Notifications for a copy of the notifications downloaded by GEG.

10/6/2021 – WVDEP UST Program responded indicating that no USTs are registered at the site. 10/18/2021 – WVDEP Environmental Enforcement responded by directing GEG to the WVDEP’s public

FOIA website located at www.dep.wv.gov. 10/18/2021 – WVDEP AST/Tanks Corrective Action Program responded by providing a spreadsheet

listing all ASTs owned by Constellium Rolled Products. GEG obtained the list of ASTs owned by Applied Partners, Inc. from the WVDEP website on October 16, 2021. GEG has been working with WVEDA and WVDEP to transfer ownership of the ASTs from Applied Partners, Inc. to WVEDA.

GEG reviewed the documentation obtained from the FOIA request and other documentation sent by WVEDA. Recommendations GEG recommends the development of a written plan of action to address all violations and unsatisfactory environmental conditions at the site. GEG recommends development of the written plan of action by a demolition and remediation contractor that is experienced in and capable of completing and/or managing all of the tasks necessary to ready the site for redevelop, as well as address all violations and unsatisfactory environmental conditions at the site. The plan of action should be developed in coordination with WVEDA. GEG can assist

Site Visit, Regulatory Agency Meeting, and File Review Summary Former Century Aluminum Century Road Millwood, Jackson County, West Virginia

Page 5

WVEDA with review of the plan and development of an effective and efficient pathway to remediation and redevelopment of the site. In the interim, GEG recommends completion of the following administrative tasks, which will result in resolution of some of the NOVs issued by the WVDEP:

Transfer of WV/NPDES Permit Number WV0000779 to WVEDA; Transfer of ownership of ASTs at the site to WVEDA; Transfer of the waste generator identification number to WVEDA;

Please contact me directly at (304) 646-7616 or via email to [email protected] with any questions regarding the correspondence or attachments. Sincerely, Greenbrier Environmental Group, Inc. _______________________________ Matthew A. Ford, LRS President Enclosures

 

ATTACHMENT I

WVDEP OER SITE VISIT SUMMARY

 

ATTACHMENT II

PHOTOGRAPHIC DOCUMENTATION

Photo Documentation – Site Visit Former Century Aluminum Millwood, Jackson County, West Virginia

Page 1 of 13

Date Taken: August 5, 2021 Photographer: Matthew Ford, LRS Description: Unlabeled 5-gallon buckets (contain fire brick paste/morter)

Date Taken: August 5, 2021 Photographer: Matthew Ford, LRS Description: Improperly stored waste carbon

Photo Documentation – Site Visit Former Century Aluminum Millwood, Jackson County, West Virginia

Page 2 of 13

Date Taken: August 5, 2021 Photographer: Matthew Ford, LRS Description: ASTs containing pitch

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: ASTs and demolition debris

Photo Documentation – Site Visit Former Century Aluminum Millwood, Jackson County, West Virginia

Page 3 of 13

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: ASTs, stack, and demolition debris

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Tote containing used oil adjacent to carbon press ASTs. Note contaminated soil.

Photo Documentation – Site Visit Former Century Aluminum Millwood, Jackson County, West Virginia

Page 4 of 13

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Bake pits filled with fire prick

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Fire brick in the bake pits

Photo Documentation – Site Visit Former Century Aluminum Millwood, Jackson County, West Virginia

Page 5 of 13

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Compression pit with oil/water

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Compression pit with oil/water

Photo Documentation – Site Visit Former Century Aluminum Millwood, Jackson County, West Virginia

Page 6 of 13

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Rail spur and railcards. Roadway reportedly constructed suing cryolite that is leaching to an

unpermitted stormwater outlet.

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Railcar reportedly containing pitch.

Photo Documentation – Site Visit Former Century Aluminum Millwood, Jackson County, West Virginia

Page 7 of 13

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Aboveground storage tank containing diesel fuel

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Aboveground storage tanks containing diesel fuel

Photo Documentation – Site Visit Former Century Aluminum Millwood, Jackson County, West Virginia

Page 8 of 13

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Groundwater monitoring well associated with the RCRA corrective action.

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Building partially filled with cryolite waste

Photo Documentation – Site Visit Former Century Aluminum Millwood, Jackson County, West Virginia

Page 9 of 13

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Building partially filled with cryolite waste

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: 55-gallon drums and other containers in maintenance building

Photo Documentation – Site Visit Former Century Aluminum Millwood, Jackson County, West Virginia

Page 10 of 13

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: 55-gallon drums, totes, and other containers in maintenance building

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: 55-gallon drums, totes, and other containers in maintenance building

Photo Documentation – Site Visit Former Century Aluminum Millwood, Jackson County, West Virginia

Page 11 of 13

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Demolition debris

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Demolition debris

Photo Documentation – Site Visit Former Century Aluminum Millwood, Jackson County, West Virginia

Page 12 of 13

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Demolition debris

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Demolition debris

Photo Documentation – Site Visit Former Century Aluminum Millwood, Jackson County, West Virginia

Page 13 of 13

Date Taken: August 6, 2021 Photographer: Matthew Ford, LRS Description: Demolition debris including rectifiers that reportedly contain asbestos containing material

 

ATTACHMENT III

COMPLIANCE EVALUATION INSPECTION, WV/NPDES PERMIT NUMBER WV0000779 (MAY 6, 2021)

 

ATTACHMENT IV

WVDEP NOTICE OF VIOLATIONS

 

ATTACHMENT V

ENVIRONMENTAL COVENANT (12/2/2016)

 

ATTACHMENT VI

WVDEP DIVISION OF AIR QUALITY

INSPECTION REPORT

 

ATTACHMENT VII

WVDEP ASBESTOS NOTIFICATIONS

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

Dry Wall

1" Domestic Water Line

12"x12" Tan Floor Tile Assumed 5

12"x12" Black Floor Tile Assumed 5

01 Fibrous Glass 7-9%, Non-Fibrous 89-91%, Gray, Insulation

None Detected

Boiler Room, North Wall, Steam Heater Piping

02 Mineral Wool 9-11% Non-Fibrous 89-91%, Gray, Insulation

None Detected

Boiler Room, North Wall, Steam Heater Piping

66BH-01 RP-32 Arc Furnace Filter NAD N14+10EA -30 Up 4 Done-RAJ

66BH-02 RP-32 1/4 Shield Insulation NAD N12+5 WJ+60 Up 1 Done-RAJ

66BH-03 RP-32 Roller Insulation NAD N11 WJ Up 0 Done-RAJ

RP-32 12"x12" Floor Tile, Black Assumed 5 Done-RAJ

B65H-01 RP-32 Super Structure Insulators NAD SEE MAP Done-RAJ

B65H-02 RP-32 2'x4' Drop Ceiling NAD Lunch Room Done-RAJ

BCH-01BCH-02BCH-03

RP-29RP-29RP-29

Pipe Insulation NAD Boiler Room Boiler Room Boiler Room

Done-RAJ

BCH-04 BCH-05BCH-06

RP-29RP-29RP-29

Pipe Insulation NAD Boiler Room Boiler Room Boiler Room

Done-RAJ

BCH-07 BCH-08 BCH-09

RP-29RP-29RP-29

Pipe Insulation NAD Boiler Room Boiler Room Boiler Room

Done-RAJ

BCH-10 BCH-11BCH-12

RP-29RP-29RP-29

Pipe Insulation NAD Boiler Room Boiler Room Boiler Room

Done-RAJ

BCH-13 BCH-14 BCH-15

RP-29RP-29RP-29

Pipe Insulation NAD Boiler #4 Up 0 Boiler #4 Up 4 Boiler #4 Up 1

Done-RAJ

BCH-16BCH-17 BCH-18

RP-29RP-29RP-29

Pipe Insulation NAD Boiler Room Up 4 Boiler Room Up 7 Boiler Room Up 1

Done-RAJ

BCH-19 RP-29 Boiler Mortar NAD Boiler #1 + 2 Done-RAJ

BCH-20 BCH-21 BCH-22

RP-29RP-29RP-29

Pipe Insulation, 18" Steam Line

NAD 2nd Flr. Boiler Room2nd Flr. Boiler Room 2nd Flr. Boiler Room

Done-RAJ

BCH-23 BCH-24 BCH-25

RP-29RP-29RP-29

Pipe Insulation, 6" Steam Line

NAD 2nd Flr. Boiler Room2nd Flr. Boiler Room 2nd Flr. Boiler Room

Done-RAJ

BCH-26 BCH-27 BCH-28

RP-29RP-29RP-29

Pipe Insulation, Domestic Water

NAD Comp. Rm. + 3 Comp. Rm. +12 Comp. Rm. +12

Done-RAJ

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

BCH-29 BCH-30 BCH-31

RP-29RP-29RP-29

Pipe Insulation, 2"Steam Line

NAD Compressor Rm. Compressor Rm. Compressor Rm.

Done-RAJ

BCH-32BCH-33BCH-34

RP-29RP-29RP-29

Pipe InsulationCondensate Line

NAD Compressor Rm. +8Compressor Rm. +8Comp. Rm. +12

Done-RAJ

BCH-35 RP-29 Rope Gasket, 3/8" NAD SE End Bldg. Cabinet Done-RAJ

BCH-36 RP-29 Rope Gasket, small black NAD Marked Cabinet Done-RAJ

BCH-37 RP-29 Rope Packing NAD Compressor Room Done-RAJ

BCH-38 Not Found 20ft.

RP-29 Rope Packing, small white 53% Chrysotile

Compressor Cabinet 2 Done-RAJ

BCH-39 RP-29 Rope Packing, 3/8" gray 53% Chrysotile

Marked Cabinet 2 Done-RAJ

BCH-40 RP-29 Rope Packing, 1/4" dark gray

NAD Marked Cabinet Done-RAJ

BCH-41 RP-29 Rope Packing, 1/2" gray NAD Marked Cabinet Done-RAJ

BCH-42 RP-29 Rope Packing, 1/8" dark gray

NAD Cabinet Done-RAJ

BCH-43BCH-44 BCH-45

RP-30 RP-30 RP-30

Pipe Insulation NAD S. Side Bldg. +15S. Side Bldg. +15S. Side Bldg. +15

Done-RAJ

BCH-46BCH-47 BCH-48

RP-30 RP-30 RP-30

Pipe Insulation, large condensate line

35% Chrysotile

S. Side Bldg. +15 S. Side Bldg. +15 S. Side Bldg. +8

2 Done-RAJ

BCH-49 BCH-50 BCH-51

RP-30 RP-30 RP-30

Pipe Insulation, small condensate line

NAD S. Side Bldg. +15S. Side Bldg. +15S. Side Bldg. +15

Done-RAJ

BCH-52 BCH-53BCH-54

RP-30 RP-30 RP-30

Pipe Insulation NAD Boiler #4 Boiler #2 Boiler #1

Done-RAJ

RP-30 Mud Joints, 2" Steam Line (1)

Assumed 7 Done-RAJ

RP-30 Mud Joints, Big (1) Assumed 7 Done-RAJ

RP-30 Mud Joints (2) Assumed 5 Done-RAJ

RP-30 Mud Joints, Condensate Line (2)

Assumed 4 Done-RAJ

RP-30 Mud Joints, Big (2) Assumed 4 Done-RAJ

RP-30 Mud Joints, Boiler Water Line (4)

Assumed 4 Done-RAJ

RP-30 Mud Joints, 6" Steam Line Assumed 2 Done-RAJ

RP-30 Mud Joints, 18' Steam Line Assumed 2 Done-RAJ

RP-30 Mud Joints, (12) Assumed 2 Done-RAJ

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

RP-30 Mud Joints, 18" Steam Line Assumed 2 Done-RAJ

RP-30 Mud Joints, Condensate Line (32)

Assumed 1 Done-RAJ

RP-30 Mud Joints, 2" Steam Line (23)

Assumed 1 Done-RAJ

RP-30 Mud Joints, Boiler Water Line, (2)

Assumed 1 Done-RAJ

BSH-01 RP-28 2'x4' Drop Ceiling Tile NAD Lunch Room Done-RAJ

RP-28 12"x12" Floor Tile Assumed 1 Done-RAJ

C212 Non-Fibrous 100%, Black, Top Layer Floor Tile

None Detected

Pot Room Canteen/Ice Area

C212-A Non-Fibrous 91-93%, Green/Black, Bottom Layer of Floor Tile & Mastic

Chrysotile7-9%

Pot Room Canteen/Ice Area

C213-1 Synthetics 9-11% Non-Fibrous 89-91%, Black/White, Insulation

None Detected

Liquid Pitch Rail Car Steam Pipe Debris

C213-2 Synthetics 9-11% Non-Fibrous 89-91%, White, Insulation

None Detected

Liquid Pitch Rail Car Steam Pipe Debris

CBH-01CBH-02CBH-03

RP-10 RP-10 RP-10

Duct Insulation on Fan Dampers

3% Chrysotile

G12 0/+39/5G11 +3/+36/0G10 -6/+36/0

5 Done-RAJ

CBH-04CBH-05CBH-06

RP-10RP-12RP-12

Round Duct Insulation 5% Chrysotile

G12 +12/+40/40G19 +28/-12/15E19 +36/+8/25

2 Done-RAJ

CBH-07 CBH-08 CBH-09

RP-10 RP-10 RP-10

Bag House Insulation 5% Chrysotile

G19 +42/+6/50G19 +34/+6/40G19 +36/+8/25

5 Done-RAJ

CBH-10 CBH-11 CBH-12

RP-12 RP-12 RP-12

Square Duct Insulation NAD G19 +18/-28/7G19 +3/-30/4F19 -2/-30/2

Done-RAJ

CBH-13CBH-14CBH-15

RP-10 RP-10 RP-10

Pipe Joint Insulation, 7/8" NAD G18 +36/-2/5G18 +2/-2/8G18 +2/-2/8

Done-RAJ

CBH-16 CBH-17 CBH-18

RP-10 RP-10 RP-10

Pipe Insulation, 7/8" NAD G18 +2/-2/11G18 +36/-2/65G18 +36/-2/12

Done-RAJ

CBH-19 CBH-20 CBH-21

RP-10 RP-10 RP-10

2" Conic Cooler Mud Joints NAD G17 +30/+8/5G17 +30/+2/65G17 +42/+2/40

Done-RAJ

CBH-22 CBH-23 CBH-24

RP-10 RP-10 RP-10

2" Conic Cooler Pipe Insulation

NAD G17 +30/+2/33G17 +36/+2/40G17 +42/+2/33

Done-RAJ

CBH-25 RP-10 Old Rope Gasket, Furnace NAD G8 0/-2/0 Done-RAJ

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

CBH-26 RP-10 Gasket Material, Furnace NAD G14 0/0/0 Done-RAJ

CBH-27 CBH-28 CBH-29

RP-10 RP-10 RP-10

Pipe Insulation, 2 1/4" NAD G18 +9/+9/5G18 0/0/11G18 0/0/28

Done-RAJ

CBH-30 CBH-31 CBH-32

RP-10 RP-10 RP-10

Pipe Joint Insulation, 2 1/2" NAD G18 0/0/10F18 0/0/30G18 0/0/28

Done-RAJ

CBH-33 CBH-34 CBH-35

RP-9 RP-9 RP-9

2'x4' Drop Ceiling Tile NAD F19 -6/+6/8F19 -6/+6/8F19 -6/+6/8

Done-RAJ

CBH-36 CBH-37 CBH-38

RP-9 RP-9 RP-9

2'x4' Drop Ceiling Tile NAD F9 -12/-12/10F9 -12/-6/10F10 -2/+10/10

Done-RAJ

CBH-39 RP-9 Rubber Duct Wrap NAD F9 -6/-4/0 Done-RAJ

CBH-40 CBH-41 CBH-42

RP-9 RP-9 RP-9

2'x4' Ceiling Tile NAD E9 +21/-10/0E9 +20/-10/0E9 +30/-10/0

Done-RAJ

CBH-43 CBH-44 CBH-45

RP-9 RP-9 RP-9

2'x4' Ceiling Tile NAD E9 +30/-10/0E9 +30/-10/0E9 +30/-10/0

Done-RAJ

CBH-46 CBH-47 CBH-48

RP-9 RP-9 RP-9

Stack Spray Line Insulation, 3 1/2"

NAD E19 +18/+1/25E19 +14/0/1E19 +6/+1/1

Done-RAJ

CBH-49 CBH-50 CBH-51

RP-9 RP-9 RP-9

Stack Spray Line Mud Joints, 3 1/2"

NAD E19 +18/+1/4E19 +16/+1/1E19 +6/0/1

Done-RAJ

CBH-52 CBH-53 CBH-54

RP-9 RP-9 RP-9

Pipe Insulation, 1" NAD E19 0/+21/0E19 0/+12/0E19 0/+1/0

Done-RAJ

CBH-55 CBH-56 CBH-57

RP-9 RP-9 RP-9

Fiber Board Wall NAD E19 +18/0/4E19 +3/0/3E19 +23/0/5

Done-RAJ

CBH-58 CBH-59 CBH-60

RP-9 RP-9 RP-9

Domestic Water Line, 3" NAD D18 +12/-4/30D13 +24/+12/30D13 +22/+12/30

Done-RAJ

CBH-61 CBH-62 CBH-63

RP-9 RP-9 RP-9

Domestic Water Line Joints, 3"

NAD D18 0/-4/30D18 +24/-4/30D18 -12/-4/30

Done-RAJ

CBH-64 CBH-65 CBH-66

RP-9 RP-9 RP-9

Domestic Water Line, 2 1/2"

NAD E18 +58/0/18E18 +30/0/30E18 -3/0/30

Done-RAJ

CBH-67 CBH-68 CBH-69

RP-9 RP-9 RP-9

Pipe Insulation, 2 1/2" NAD D18 +5/0/30D18 +12/0/30 D18 +18/0/30

Done-RAJ

CBH-70 CBH-71 CBH-72

RP-9 RP-9 RP-9

Pipe Insulation, 1" NAD E19 0/-14/20E19 0/+24/20 E19 0/+39/20

Done-RAJ

CBH-73 CBH-74 CBH-75

RP-9 RP-9 RP-9

Steam Line Insulation, 2 1/4"

NAD D9 0/0/25D9 +34/0/30E9 0/-9/25

Done-RAJ

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

CBH-76 CBH-77 CBH-78

RP-9 RP-9 RP-9

Domestic Water Line Insulation, 2 1/2"

NAD D9 0/0/25D9 +34/0/30 E9 0/0/25

Done-RAJ

CBH-79CBH-80 CBH-81

RP-9 RP-9 RP-9

Domestic Water Line Insulation, 2 1/2"

NAD D8 +24/0/30D5 +24/+3/30D4 +24/+8/30

Done-RAJ

CBH-82 RP-9 Domestic Water Line Insulation, 2 1/2"

NAD D5 +24/+5/30 Done-RAJ

CBH-83CBH-84CBH-85

RP-9 RP-9 RP-9

Pipe Insulation, 2 1/2" 5% Chrysotile

E2 +21/0/20E2 +50/0/20E2 +35/0/20

5 Done-RAJ

CBH-86CBH-87CBH-88

RP-9RP-9RP-9

Pipe Insulation, 2 1/2" NAD D3 +13/+3/30D3 +50/+3/30 F3 0/+3/30

Done-RAJ

CBH-89CBH-90CBH-91

RP-9RP-9RP-9

Pipe Joint Insulation, 2 1/2" 5% Chrysotile

E2 +2/+3/20E2 0/+3/28E2 -1/+3/30

7 Done-RAJ

CBH-92CBH-93CBH-94

RP-8RP-8RP-8

Pipe Insulation, 1" NAD C9 +11/-5/10C9 +9/-8/10 C9 +9/+1/10

Done-RAJ

CBH-95CBH-96

RP-8RP-8

Pipe Joint Insulation, 1" NAD C9 +9/-10/10C9 +9/-10/10

Done-RAJ

CBH-97CBH-98CBH-99

RP-8RP-8RP-8

2'x4' Ceiling Tile NAD C9 +14/-19/8C9 +12/-5/8 C9 +11/-11/8

Done-RAJ

CBH-100CBH-101CBH-102

RP-8 RP-8 RP-8

2'x4' Ceiling Tile NAD C9 +29/-8/8 C9 +22/-16/8C9 +42/-12/8

Done-RAJ

CBH-103 CBH-104 CBH-105

RP-8 RP-8 RP-8

2'x4' Ceiling Tile NAD C9 +19/-19/8.5C9 +8/-24/8.5 C9+36/-24/8.5

Done-RAJ

CBH-106 CBH-107 CBH-108

RP-8 RP-8 RP-8

Pipe Insulation, 2 1/2" 10%Chrysotile,20%Amosite

A19 -30/+3/30 A19 -6/+3/30 A19 0/+6/30

5 Done-RAJ

CBH-109 CBH-110 CBH-111

RP-8 RP-8 RP-8

Steam Line Insulation, 6 1/2"

NAD A19 -14/+5/28B19 0/+5/28B18 +1/-10/30

Done-RAJ

CBH-112 CBH-113CBH-114

RP-8 RP-8 RP-8

Domestic Water Line Insulation

NAD A19 -27/+12/28 B19 +1/+14/27 B18 +46/-3/30

Done-RAJ

CBH-115 CBH-116CBH-117

RP-8 RP-8 RP-8

Pipe Insulation, 3 1/4" NAD A19 -12/+14/28B19 -1/+15/27B18 -1/+8/27

Done-RAJ

CBH-118 RP-8 Steam Line Insulation, 6 1/2"

15% Chrysotile

A19 -5/+6/28 5 Done-RAJ

CBH-119 CBH-120 CBH-121

RP-8 RP-8 RP-8

Domestic Water Line Joints

NAD B19 +2/+10/27B18 -12/-4/27B18 +3/-14/30

Done-RAJ

CBH-122CBH-123CBH-124

RP-8 RP-8 RP-8

Pipe Insulation, 4 1/4" NAD C19 -2/+2/28C18 -8/+3/34C8 -6/+9/0

Done-RAJ

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

CBH-125 CBH-126 CBH-127

RP-8 RP-8 RP-8

Mud Joints, 1" 2% Chrysotile

D2 -5/0/20D2 -5/-1/16 D2 -5/-9/5

7 Done-RAJ

CBH-128 CBH-129CBH-130

RP-8 RP-8 RP-8

Pipe Insulation, 1" NAD D2 -5/0/21D2 -5/-1/16D2 -5/-9/5

Done-RAJ

CBH-131CBH-132 CBH-133

RP-8 RP-8 RP-8

Pipe Insulation, 1 1/2" 25% Amosite

D1 -2/-6/20D1 -2/0/16D1-2/0/6

5 Done-RAJ

CBH-134 CBH-135 CBH-136

RP-8 RP-8 RP-8

Duct Wrap NAD C9 +15/-12/8C9 +14/-10/8 C9 +13/-6/8

Done-RAJ

CBH-137 CBH-138 CBH-139

RP-8 RP-8 RP-8

Domestic Water Line Insulation

NAD C19 +9/0/3D18 0/-4/27D18 -6/-4/30

Done-RAJ

CBH-140 CBH-141 CBH-142

RP-8 RP-8 RP-8

Domestic Water Line Joints

NAD C19 +9/0/3D18 0/-4/29 D18 0/-10/20

Done-RAJ

CBH-143 CBH-144 CBH-145

RP-8 RP-8 RP-8

Pipe Insulation, 2" NAD C18 +2/-1/20C18 0/-1/28C18 -2/-1/30

Done-RAJ

CBH-146 CBH-147CBH-148

RP-8 RP-8 RP-8

Mud Joints, 2" 10% Chrysotile

C18 -2/-1/30C18 -1/-1/30C18 0/-1/28

5 Done-RAJ

CBH-149 RP-8 Pipe Insulation, 3" NAD C9 0/-1/10 Done-RAJ

CBH-150 CBH-151 CBH-152

RP-8 RP-8 RP-8

2'x4' Drop Ceiling Tile NAD C19 -6/20/8C19 -26/32/8 C19 -6/-32/8

Done-RAJ

RP-8 12"x12" Floor Tile, Black with White; Building 51

Assumed C19 4 Done-RAJ

RP-8 12"x12" Floor Tile, Control Room

Assumed C19 4 Done-RAJ

RP-8 12"x12" Floor Tile, Black with White; Building 52

Assumed C19 1 Done-RAJ

RP-8 12"x12" Floor Tile, Building 59

Assumed C19 1 Done-RAJ

RP-8 12"x12" Gray Marbled Floor Tile, Substation

Assumed C19 1 Done-RAJ

RP-8 12"x12" Floor Tile, Building 59-lunch room

Assumed C19 1 Done-RAJ

CMG-01 RP-31 2'x4' Ceiling Tile NAD Lunch Room Done-RAJ

CMG-02 RP-31 Gasket Material NAD B2 -2/+15/4 Done-RAJ

CMG-03CMG-04CMG-05

RP-31RP-31RP-31

Pipe Insulation, 16" NAD A1 +12/2/14A1 +24/2/14A2 -5/+2/14

Done-RAJ

CMG-06 RP-31 Pipe Insulation, 2" NAD A2 -20/+2/18 Done-RAJ

CMG-07 RP-31 Pipe Insulation, 3" 20% Chrysotile

A2 -4/+2/18 5 Done-RAJ

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

CMG-08CMG-09

RP-31RP-31

Pipe Insulation, 2" NAD C1 0/-1/14G1 0/0/16

Done-RAJ

CMG-10 RP-31 Caulking NAD H1 0/+2/5 Done-RAJ

CMG-11 RP-31 4" Wrap NAD M1 +10/-3/4 Done-RAJ

CMG-12CMG-13

RP-31RP-31

Pipe Insulation, 3" 20% Chrysotile

N2 0/+4/14N2 0/+8/24

5 Done-RAJ

CMG-14 RP-31 C100 Preformed Sheeting NAD O1 -17/+4/4 Done-RAJ

CMG-15 RP-31 Preformed Grating NAD Q2 -2/-2/3 Done-RAJ

CMG-16 RP-31 Door Gasket to Kiln 98% Chrysotile

Q3 -20/-2/3 2 Done-RAJ

CMG-17 RP-31 Kiln Vent Cap Plate 65% Chrysotile

Q3 -20/0/3 2 Done-RAJ

CMG-18CMG-19CMG-20

RP-31RP-31RP-31

Pipe Insulation, 6" NAD Q3 0/+5/1Q3 0/+5/4 Q3 0/+5/6

Done-RAJ

CMO-01 RP-5 2'x4' Fissured Ceiling Tile NAD Supervisors Office Done-RAJ

CMO-02 RP-5 2'x4' Ceiling Tile NAD Tool Room Done-RAJ

CMO-03 RP-5 12"x12" Ceiling Tile, Spine Mounted

NAD Secretaries Office Done-RAJ

CMO-04 RP-5 Pot Shield NAD Storage Room Done-RAJ

CMO-05 RP-5 Contact Bars NAD Taylor-Dunn Control Bin Done-RAJ

CMO-06 RP-5 Board Separator NAD Storage Bin, 2nd Shelf Done-RAJ

CMO-07 RP-5 Electric Contact Board 7% Chrysotile

2nd Cabinet, 2nd Shelf 2 Done-RAJ couldn't find

CMO-08 RP-5 Radiator Hoses NAD Storage Room Done-RAJ

CMO-09 RP-5 Belt Hoses NAD Stock Room Wall Done-RAJ

CMO-10 RP-5 Packing Ring NAD Stock Room, Drawer 4 Done-RAJ

CMO-11 RP-5 O-Ring NAD Stock Room Done-RAJ

CMO-12 RP-5 Transmission Material NAD Stock Room Done-RAJ

CMO-13 RP-5 Fan Belt NAD Stock Room Done-RAJ

CMO-14 RP-5 Fuel Line Hose NAD Stock Room Done-RAJ

CMO-15 RP-5 Grey Rigid Gasket Material 45% Chrysotile

Stock Room 1 Done-RAJ couldn't find

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

CMO-16 RP-5 Grey Soft Gasket NAD Stock Room, R8 Cabinet Done-RAJ couldn't find

CMO-17 RP-5 Red Soft Gasket NAD Stock Room, R8 Cabinet Done-RAJ

CMO-18 RP-5 Inner Soft Metal Jacket Gasket

60% Chrysotile

Stock Room, 6th Shelf 2 Done-RAJ

CMO-19 RP-5 Flex Hose, 3" NAD Stock Room Done-RAJ

CMO-20 RP-5 Flex Hose, 2" NAD Stock Room Done-RAJ

CMO-21 RP-5 Paper/Metal Gasket NAD Stock Room Done-RAJ

CMO-22 RP-5 Red Rigid Gasket 70% Chrysotile

Stock Room 4 Done-RAJ couldn't find

CMO-23 RP-5 Silver Backed Gasket 15% Chrysotile

Stock Room 1 Done-RAJ couldn't find

CMO-24 RP-5 Core Gasket Material NAD Stock Room Done-RAJ

CMO-25 RP-5 Hose, 1" NAD Stock Room Done-RAJ

CMO-26 RP-5 Hose, 1/2" NAD Stock Room Done-RAJ

CMO-27 RP-5 Metal Gasket and Filter 40% Chrysotile

Stock Room 5 Done-RAJ couldn't find

CMO-28 RP-5 Tan Gasket Material 35% Chrysotile

Stock Room 1 Done-RAJ couldn't find

CMO-29 RP-5 Green Gasket Material NAD Stock Room Done-RAJ

RP-5 12"x12" Tan Floor Tile Assumed 5

RP-5 12"x12" Black Floor Tile Assumed 5

CPRO-1 Fibrous Glass 79-81%Non-Fibrous 19-21%Yellow, Insulation

None Detected

Hallway, DuctworkAbove Drop Ceiling

CPRO-2 Mineral Wool 74-76%Non-Fibrous 24-26%Tan, Mud

None Detected

Bathroom, Above Drop Ceiling, Mudded Fitting

CPRO-3 Mineral Wool 89-91%Non-Fibrous 9-11%White, Ceiling Tile

None Detected

Hallway, Above Drop Ceiling

CUG-01 RP-36 Dry Wall NAD SEE MAP Done-RAJ

CUG-02 RP-36 Dry Wall Tape Joint NAD SEE MAP Done-RAJ

GC-01GC-02GC-03

RP-13RP-13RP-13

Pipe Insulation NAD E1 0/+1/4E1 0/+3/4 E1 0+5/3

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

GC-04GC-05GC-06

RP-13RP-13RP-13

Pipe Insulation, 3 1/2" NAD E2 +2/+6/6C2 +2/+14/6 C2 -2/-3/6

GC-07GC-08

RP-13RP-13

Pipe Joint Insulation 5% Chrysotile

C2 +2/-3/7B2 +2/+10/7

5 couldn't find

GC-09GC-10GC-11

RP-13RP-13RP-13

Pipe Insulation, 3 1/2" NAD B2 -2/+6/6C2 -2/+6/6D2 -2/+2/6

GC-12GC-13GC-14

RP-13RP-13RP-13

Pipe Insulation, 4" 3% Chrysotile2% Amosite

C2 -2/+4/7C2 +2/+4/7C2 +4/+6/7

7

GC-15GC-16GC-17

RP-13RP-13RP-13

Pipe Insulation NAD C2 -3/+4/6C2 +3/+8/6C2 0/+6/8

GC-18GC-19GC-20

RP-13RP-13RP-13

Pipe Insulation, 1" NAD E3 +2/+11/6E3 +2/+11/2E3 0/7/8

GC-21 RP-13 Pipe Insulation, 1" 10% Chrysotile

E3 -1/+7/8 7 couldn't find

GC-22GC-23GC-24

RP-13RP-13RP-13

Pipe Insulation, 4" 10% Chrysotile

E3 0/+6/7E3 -2/+7/7E3 -4/+7/9

5 couldn't find

GC-25GC-26GC-27

RP-13RP-13RP-13

Pipe Insulation, 8" 5% Chrysotile15% Amosite

E3 -1/+12/6E3 +2/+2/8B3 +2/+4/8

7 couldn't find

GC-28GC-29GC-30GC-31

RP-13RP-13RP-13RP-13

Pipe Insulation, 8" NAD B3 +2/+12/7C3 +2/+6/7C3 +5/+4/8E3 +2/-4/8

GC-32 RP-13 Pipe Insulation, 8" 5% Chrysotile15% Amosite

C3 +1/+3/4 7 Abated/ Removed

GC-33 RP-13 Pipe Insulation, 3/4" NAD J1 -3/0/4

GC-34 RP-13 Pipe Insulation, 3/4" 3% Chrysotile20% Amosite

J1 11/-1/7 7 Abated/ Removed

GC-35 RP-14 Pipe Joint Insulation, 3/4" 10% Chrysotile

J1 -10/-1/2 7 Abated/ Removed

GC-36 RP-14 Pipe Insulation, 3/4" 3% Chrysotile20% Amosite

J1 11/-1/10 7 Abated/ Removed

GC-37 RP-14 Pipe Joint Insulation NAD J1 +5/-12/4

GC-38 RP-14 Pipe Insulation, 1 1/2" 15% Chrysotile

G1 0/+5/3 7 Abated/ Removed

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

GC-39 RP-14 Pipe Insulation, 3/4" 3% Chrysotile20% Amosite

G2 4/5/10 7 Abated/ Removed

GC-40 RP-14 Pipe Insulation, 1 1/2" NAD G2 +5/0/10

GC-41GC-42GC-43

RP-13RP-13RP-13

Pipe Insulation, 1 1/2" NAD C9 0/-10/5C9 0/-10/2C9 0/-14/2

GC-44GC-45

RP-13RP-13

Pipe Joint Insulation, 1 1/2" 2% Chrysotile

D7 -4/+11/16D7 -4/+15/16

5

GC-46 RP-13 Pipe Insulation, 1" 2% Chrysotile

D7 -8/+14/18 2

GC-47 RP-13 Pipe Insulation, 1 1/4" NAD E8 +3/0/18

GC-48GC-49GC-50

RP-13RP-13RP-13

Pipe Insulation, 1 1/4" NAD E7 -5//-1/18E8 +2/-1/18E8 -8/-1/18

GC-51 RP-13 Pipe Insulation, 2" NAD E8 -4/-2/18

GC-52 RP-13 Pipe Insulation Mud Joint, 2"

15% Chrysotile

E9 +2/-2/18 2 Abated/ Removed

GC-53 RP-13 Pipe Insulation, 1 1/2" 10% Chrysotile

E9 +2/-2/18 5

GC-54 RP-13 Pipe Insulation, 1 1/2" NAD D9 +1/+3/18

GC-55GC-56

RP-13RP-13

Pipe Insulation Mud Joint, 1 1/2"

10% Chrysotile

D9 0/+5/18D9 +3/0/18

5 Abated/ Removed

GC-57 RP-13 Pipe Insulation, 1 1/2" NAD B9 +2/+6/18

GC-58 RP-13 Pipe Insulation Joint, 1 1/2" 2% Chrysotile

B9 +3/0/18 2 Abated/ Removed

GC-59 RP-13 VERIFY

GC-60GC-61

RP-13 RP-13

Pipe Insulation Mud Joint, 1"

3% Chrysotile

B9 +5/-1/22B9 +5/-4/22

2 Abated/ Removed

GC-62 RP-13 Pipe Insulation, 1" NAD B9 +5/-2/22

GC-63 RP-13 Pipe Insulation, 1 1/2" NAD B9 0/+1/18

GC-64 RP-13 Pipe Insulation Mud Joint, 1"

3% Chrysotile

B9 +1/-8/22 2 Abated/ Removed

GC-65GC-66

RP-13RP-13

Pipe Insulation, 1" NAD B9 +1/+10/22B9 +1/+15/22

GC-67GC-68GC-69

RP-13RP-13RP-13

Pipe Insulation, 1" NAD A9 +3/+2/22A9 +3/+10/22A9 +3/+15/22

GC-70 RP-13 Pipe Insulation, 1 1/4" NAD B8 0/-5/22

GC-71 RP-13 Pipe Joint Insulation, 1 1/4" 3% Chrysotile

B8 0/+8/22 5 Abated/ Removed

GC-72 RP-13 Pipe Insulation, 1 1/4" NAD B8 0/-10/22

GC-73 RP-13 Pipe Joint Insulation, 1 1/4" 3% Chrysotile

B8 0/+18/22 5 Abated/ Removed

GC-74 RP-13 Pipe Insulation Joint, 1 1/2" 2% Chrysotile

B8 +2/-1/18 2 Abated/ Removed

GC-75GC-76

RP-13RP-13

Pipe Insulation, 2" NAD B8 +15/+1/22B6 +15/+1/18

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

GC-77 RP-13 Pipe Insulation Joint, 1 1/2" 2% Chrysotile

B15 0/-4/18 2 Abated/ Removed

GC-78 RP-13 Pipe Insulation, 2" NAD B5 0/+3/18

GC-79GC-80GC-81

RP-13RP-13RP-13

Block Insulation w/Cloth Cover

15% Chrysotile7% Amosite

U7 Exh.C8 +4/+12/4C8 +8/+14/4C8 +8/+12/4

7 Abated/ Removed

GC-82GC-83GC-84

RP-13RP-13RP-13

Air Duct Insulation 10% Chrysotile3% Amosite

C8 +3/12/10D9 -10/-4/12D9 -12/-6/14

2 Abated/ Removed

GC-85 RP-13 Air Duct NAD D8 +10/-2/16

GC-86GC-87GC-88

RP-13RP-13RP-13

Duct Wrap 10% Chrysotile

A4 -8/+5/3A4 -8/+5/4A4 -8/+5/5

5

GC-89 RP-13 1/2" Hose Insulation NAD A4 -12/+3/2

GC-90GC-91GC-92

RP-13RP-13RP-13

Mechanical Joint Vibration Material

NAD A4 -16/+2/3A4 -17/+3/2 A4 -16/+4/3

GC-93 RP-13 Pipe Insulation, 2" NAD E6 -8/+10/12

GC-94 RP-13 Mud Joint, 2" 15% Chrysotile

E8 -4/+10/12 5 Abated/ Removed

GC-95 RP-13 Pipe Insulation, 2" NAD E8 -2/+10/12

GC-96 VERIFY

GC-97 RP-14 Mud Joint, 1/2" 20% Chrysotile15% Amosite

A3 +1/0/4 7 Abated/ Removed

GC-98GC-99

RP-14RP-14

Pipe Insulation, 1/2" 20% Chrysotile25% Amosite

A3 -1/0/6A1 0/0/4

7 Abated/ Removed

GC-100GC-101

RP-14RP-14

Mud Joint, 1/2" 20% Chrysotile15% Amosite

A1 0/0/7A1 0/0/4

7 Abated/ Removed

GC-102 RP-14 Pipe Insulation, 1/2" 20% Chrysotile25% Amosite

C1 0/0/4 7 Abated/ Removed

GC-103GC-104GC-105

RP-14RP-14RP-14

Mixer Unit Blanket Insulation

NAD Unit 1 A2 -1/+6/5Unit 1 A2 +7/+10/4Unit +7/+6/5

GC-106GC-107GC-108

RP-14RP-14RP-14

Mixer Unit #9 Insulation NAD A2 +3/+5/6A2 +8/+5/9A2 +3/+10/4

GC-109GC-110GC-111

RP-14RP-14RP-14

Mixer Unit #2 Insulation NAD B2 -3/+3/4B2 -3/-2/3B2 -4/-4/3

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

GC-112GC-113GC-114

RP-14RP-14RP-14

Mixer Unit #10 Insulation NAD B2 +4/+4/3B2 +5/-2/5B2 +5/+5/6

GC-115GC-116GC-117

RP-14RP-14RP-14

Mixer Unit #3 Insulation NAD C2 -4/-8/3C2 -4/-10/5C2 -4/-5/4

GC-118GC-119GC-120

RP-14RP-14RP-14

Mixer Unit #11 Insulation NAD C2 +5/-5/4C2 +4/-6/6C2 +5/-10/6

GC-121GC-122GC-123

RP-14RP-14RP-14

Mixer Unit #12 Insulation NAD C2 +4/-1/5C2 +5/+6/7C2 +4/+6/3

GC-124GC-125GC-126

RP-14RP-14RP-14

Mixer Unit #5 Insulation NAD D2 -2/+8/7D2 -4/+10/5D2 -4/+3/4

GC-127GC-128GC-129

RP-14RP-14RP-14

Mixer Unit #13 Insulation Blanket

NAD D2 +4/-8/4D2 +4/-2/7 D2 +3/-2/3

GC-130GC-131GC-132

RP-14RP-14RP-14

Mixer Unit #6 Insulation Blanket

NAD D2 -4/+2/6D2 -6/+2/3D2 -4/+8/4

GC-133GC-134GC-135

RP-14RP-14RP-14

Mixer Unit #14 Insulation Blanket

NAD D2 +3/+1/8D2 +3/+1/3D2 +3/+7/4

GC-136GC-137GC-138

RP-14RP-14RP-14

Mixer Unit #7 Insulation Blanket

NAD E2 -4/-10/3E2 -4/-10/8E2 -4/-1/6

GC-139GC-140GC-141

RP-14RP-14RP-14

Mixer Unit #15 Insulation Blanket

91% Chrysotile

E2 +4/-1/6E2 +4/-1/2 E2 +4/-7/4

2

GC-142 RP-14 Pipe Insulation, 1/2" 21% Chrysotile

E2 +3/-1/3 2 Abated/ Removed

GC-143GC-144GC-145

RP-14RP-14RP-14

Mixer Unit #8 Insulation NAD E2 -4/+2/7E2 -4/+2/3E2 -8/+8/4

GC-146GC-147GC-148

RP-14RP-14RP-14

Mixer Unit #16 Insulation 90% Chrysotile

E2 +3/+2/3E2 +3/+2/5E2 +3/+2/7

5

GC-149 RP-14 Pipe Insulation, 6" NAD F3 +1/+2/5

GC-150 RP-14 1/2" Hose Line Insulation NAD F2 0/-4/2

GC-151 RP-14 Pipe Insulation, 6" NAD B3 +3/+4/5

GC-152GC-153

RP-14RP-14

Mud Joint, 6" 5% Chrysotile

B2 +3/+4/8B7 -10/-12/11

2 Abated/ Removed

GC-154 RP-14 Pipe Insulation, 6" NAD B7 -10/-14/11

GC-155 RP-14 Mud Joint, 6" 5% Chrysotile

B8 +4/+1/11 2 Abated/ Removed

GC-156 RP-14 Pipe Insulation, 6" NAD B8 +4/0/11

GC-157 RP-14 Mud Joint, 3" 4% Chrysotile

B8 +1/+2/11 2 Abated/ Removed

GC-158 RP-14 Pipe Insulation, 3" NAD B8 +1/+2/11

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

GC-159 RP-14 Mud Joint, 3" 4% Chrysotile

A7 -3/+1/11 2 Abated/ Removed

GC-160 RP-14 Pipe Insulation, 3" NAD A7 -3/+1/6

GC-161 RP-14 Mud Joint, 3" 4% Chrysotile

B9 +1/+1/11 2 Abated/ Removed

GC-162 RP-14 Pipe Insulation, 3" NAD B9 +2/+1/11

GC-163GC-164GC-165

RP-14RP-14RP-14

2'x4' Ceiling Tile NAD See MapSee MapSee Map

GC-166 GC-167 GC-168

RP-14RP-14RP-14

Press Board Ceiling NAD See MapSee MapSee Map

GC-170 RP-14 30" Air Duct Insulation NAD D7 -12/-2/22nd Floor

GC-171 RP-14 30" Air Duct Insulation 15% Chrysotile

D7 -12/-2/42nd Floor

5

GC-172GC-173GC-174

RP-14RP-14RP-14

Tank Insulation 2% Chrysotile

D8 +3/+1/7 D8 +2/+3/9D8+1/+1/9

5 Abated/ Removed

GC-175GC-176

RP-14RP-14

Pipe Insulation, 3/4" NAD D8 +2/0/5D8 +2/+1/3

GC-177 GC-178 GC-179

RP-14 RP-14 RP-14

Pipe Insulation, 1 1/2" NAD D8 -3/0/15D8 -11/0/15D9 +2/0/15

GC-180GC-181GC-182

RP-15RP-15 RP-15

Tank Insulation 65% Chrysotile

D7 -4/-11/3D7 -7/+8/4 D7 -4/+8/2

5 Abated/ Removed

GC-183 RP-14 Pipe Insulation, 3/4" NAD D8 +2/+2/5

GC-184 RP-15 30" Air Duct Insulation 15% Chrysotile

D7 -12/-2/4 3rd Floor 5

GC-185 RP-15 Vibration Joint NAD D9 +3/+3/8

GC-186 GC-187

RP-16 RP-16

30" Air Duct Insulation 20% Chrysotile

D7 -12/-4/4 4th Floor D7 -12/-4/2 4th Floor

5

GC-188 RP-16 30" Air Duct Insulation 15% Chrysotile

D7 -12/-3/6 5

GC-189 GC-190 GC-191

RP-16 RP-16 RP-16

Tank Insulation 20% Chrysotile

C8 +80/+10/5 C8 +8/+2/4 C8 +3/+5/5

2

GC-192 RP-16 Vibration Joint NAD E7 +5/-1/2

GC-193GC-194GC-195

RP-16 RP-16 RP-16

Chute Insulation 12% Chrysotile

E8 0/+5/7 E8 -10/+6/8 E9+2/+4/8

5

GC-196 GC-197 GC-198

RP-17 RP-17 RP-17

P2 Cyclone 12% Chrysotile

E8 +12/+7/6 E8 +7/+11/5E8 +12/+5/7

2

GC-199 GC-200 GC-201

RP-17 RP-17 RP-17

Bag House 10% Chrysotile

D8 +2/-7/5D8 -8/-7/6D8 -18/-7/4

2

GC-202 GC-203 GC-204

RP-17 RP-17 RP-17

Old Insulation 12% Chrysotile

D8 +1/-10/8 D8 -8/-10/9D8 +6/-14/5

5

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

GC-205 RP-16 1 1/2" Fire Hose NAD E1 -5/0/4

GC-206 RP-15 Mud Joint, 1 1/2" 80% Chrysotile

3rd Floor CentralSee Map

5 Abated/ Removed

GC-207 RP-15 Pipe Insulation, 1 1/2" NAD 3rd Floor Central See Map

GC-208 Pipe Insulation NAD See Map

GC-209 Pipe Insulation, 2 1/2" NAD Lunch Room/See Map

GC-210 GC-211 GC-212

2'x4' Ceiling Tile NAD West Entry Control. Window W. Wall North Entry

RP-23 12"x12" Floor Tile, Black Assumed 2

RP-23 12"x12" Floor Tile, Black with white streaks

Assumed 5

GCCTGH-01GCCTGH-02GCCTGH-03

RP-36 RP-36 RP-36

Pipe Insulation, 4" NAD Listed on Map Listed on Map Listed on Map

Done-RAJ

GCCTGH-04 RP-36 Red Hose, 1 1/2" NAD Listed on Map Done-RAJ

GCCTGH-05 RP-36 Red Hose, 2" NAD Listed on Map Done-RAJ

GCCTGH-06GCCTGH-07GCCTGH-08

RP-36 RP-36 RP-36

Preformed Shroud NAD West Seam South West Base East Seam

Done-RAJ

GCCTG2-01GCCTG2-02 GCCTG2-03

RP-36 RP-36 RP-36

Pipe Insulation, 4" 15% Chrysotile

Listed on Map Listed on Map Listed on Map

7 Abated/ Removed

GCCTG2-04 GCCTG2-05 GCCTG2-06

RP-36 RP-36 RP-36

Fan Shroud NAD North Side East Side South Side

GCCTG2-07 GCCTG2-08 GCCTG2-09

RP-36 RP-36 RP-36

Insulation Wrap NAD Listed on Map Listed on Map Listed on Map

GCSG-01 RP-11 Gasket 70% Chrysotile

Shelf SEE MAP 5 Abated/ Removed

GCSG-02 RP-11 Conveyor Belt Type NAD Above Off. SEE MAP

GCSG-03 GCSG-04 GCSG-05

RP-11 RP-11 RP-11

1/2" Pipe Insulation NAD SEE MAP SEE MAP SEE MAP

GCSG-06 RP-11 Green Gasket Material NAD Storage SEE MAP

GCSG-07 RP-11 Yellow Gasket Material NAD Storage SEE MAP

GCSG-08 RP-11 2" Hose NAD SEE MAP

GCSG-09 RP-11 3" Wide Belt NAD SEE MAP

GCSG-10 RP-11 Rubber Sleeve Blanket NAD Shelves SEE MAP

GCSG-11 RP-11 Rubber Sleeve Collar NAD Shelves SEE MAP

GCSG-12 RP-11 Rubber Sleeve Square NAD Shelves SEE MAP

GCSG-13 RP-11 Square Gasket NAD Shelves SEE MAP

GCSG-14 RP-11 1 1/2" Hose NAD Shelves SEE MAP

GCSG-15 RP-11 Rubber Boot NAD Shelves SEE MAP

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

GCSG-16 RP-11 Laminated Pad w/ White Center

NAD Shelves SEE MAP

GCSG-17 RP-11 Gray Laminated PAD 10% Chrysotile

Shelves SEE MAP 5

GCSG-18 RP-11 1/2" Rope Gasket 35% Chrysotile

Shelves SEE MAP 5

GCSG-19 RP-11 1/4" Rope Gasket 40% Chrysotile

Shelves SEE MAP 5

GCSG-20 RP-11 1/16" Dead Rope Gasket 15% Chrysotile

Shelves SEE MAP 5

GCSG-21 RP-11 1" Rope Gasket NAD Shelves SEE MAP

GCSG-22 RP-11 1/8" x 1/2" Rope Gasket NAD Shelves SEE MAP

GCSG-23 RP-11 3/8" Rope Gasket 35% Chrysotile

Shelves SEE MAP 5

GCSG-24 RP-11 1/8" Rope Gasket 25% Chrysotile

Shelves SEE MAP 5

GCSG-25 RP-11 Tan Gasket Material NAD Shelves SEE MAP

GCSG-26 RP-11 2'x4' Ceiling Tile with Punched Holes

NAD SEE MAP

GCSG-27 RP-11 Gray Gasket Material NAD SEE MAP

GCSG-28 RP-11 White 3/4" Packing NAD 2nd Shelf SEE MAP

GCSG-29 RP-11 Orange Gasket Material NAD 6th Shelf SEE MAP

GCSG-30 RP-11 Tan Gasket Material NAD 6th Shelf SEE MAP

GCSG-31 RP-11 2 1/2" Wipe Belt NAD 2nd Shelf SEE MAP

GCSG-32 RP-11 Conveyor Belt-Tan NAD SEE MAP

GCSG-33 RP-11 1/2" Hose NAD SEE MAP

RP-11 12"x12" Floor Tile Assumed 5

LBH-01 LBH-02 LBH-03

RP-4 RP-4 RP-4

Steam Pipe Insulation NAD SEE MAP Up 12 SEE MAP Up 12 SEE MAP Up 12

Done-RAJ

LBH-04 LBH-05 LBH-06

RP-4 RP-4 RP-4

Water Line Domestic NAD SEE MAP Up 12 SEE MAP Up 12 SEE MAP Up 12

Done-RAJ

LBH-07 LBH-08 LBH-09

RP-4 RP-4 RP-4

Tank Insulation 3 tanks approx. 300 gal covers entire tanks

30% Chrysotile 20% Amosite10% Crocidolite

Mechanical RoomMechanical Room Mechanical Room

1 Done-RAJ

MSG-01 MSG-02 MSG-03

RP-5 Pipe Insulation, 1 1/2" NAD 14L -1/0/515L +1/0/1211L -1/0/12

Done-RAJ

MSG-04MSG-05 MSG-06

RP-5 Pipe Insulation, 1" NAD 13L -1/0/1213H -1/0/1215H -1/0/12

Done-RAJ

MSG-07 RP-5 Rope, white NAD 13L -4/0/4 Done-RAJ

MSG-08 MSG-09 MSG-10

RP-5 Pipe Insulation, 8" NAD 17H +1/+4/117H +1/+4/417H +1/+4/6

Done-RAJ

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

MSG-11 RP-5 Cloth Wrap NAD H15 +6/+4/7 Done-RAJ

MSG-12 RP-5 Bulletin Board NAD K5 +10/+2/4 Done-RAJ

MSG-13 RP-5 Fire Door Gasket Material 70% Chrysotile

K6 +10/+2/5 5 Done-RAJ

MSG-14 RP-5 Transit Board 50% Chrysotile

L13 -15/0/9 1 Done-RAJ

MSG-15 RP-5 2'x4' Ceiling Tile, Fissured NAD L4 -10/-4/7 Done-RAJ

MSG-16 RP-5 Green Hose, 1/2" NAD L15 0/0/0 Done-RAJ

MSG-17 RP-5 Red Hose, 1" NAD L4 -8/-2/0 Done-RAJ

MSG-18 RP-5 Cloth Covered Hose, 3/4" NAD K3 +10/-2/3 Done-RAJ

MSG-19 RP-5 Blue Gasket Material NAD N4 +2/+12/9 Done-RAJ

MSG-20 RP-5 Black Hose, 1" NAD H3 -2/+10/5 Done-RAJ

MSG-21 RP-5 Ring Gasket NAD H3 -7/0/6 Done-RAJ

MSG-22 RP-5 Spray on Coating 3% Chrysotile

L3 -7/+8/4 5 Done-RAJ

MSG-23 RP-5 Gasket Rope, 1/8" 35% Chrysotile

L3 -12/5/5 3 Done-RAJ

MSG-24 RP-5 Gasket Cloth NAD E6 +8/-20/1 Done-RAJ

MSG-25 RP-5 Rope Gasket NAD E4 -2/-4/3 Done-RAJ

MSG-26 MSG-27 MSG-28

RP-5 Tank Insulation NAD E3 +10/+20/4E3 +10/+22/2E3 +12/+22/2

Done-RAJ

MSG-29 MSG-30 MSG-31

RP-5 Pipe Insulation NAD E3 +1/+18/12E2 +7/+14/2F2 0/-1/14

Done-RAJ

MSG-32 MSG-33

RP-5 Pipe Insulation, 4" NAD E2 0/+5/24E2 +3/+2/24

Done-RAJ

MSG-34 MSG-35

RP-5 Pipe Insulation, 2" NAD E2 +1/+1/24E2 +1/+1/18

Done-RAJ

MSG-36 RP-5 Vacuum Hose, 5" NAD E2 +4/+3/5 Done-RAJ

MSG-37 RP-5 VERIFY Done-RAJ

MSG-38 RP-5 Pipe Insulation, 2" NAD B10 +1/0/10 Done-RAJ

MSG-39 RP-5 Yellow Ring Isolator, 1" NAD E8 +6/+8/4 Done-RAJ

MSG-40 RP-5 Red Isolator Board NAD E8 +7/+18/4 Done-RAJ

MSG-41 RP-5 Green Hose, 1" NAD E10 +1/+12/5 Done-RAJ

MSG-42 RP-5 Black Hose, 1" NAD E10 +2/+12/5 Done-RAJ

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

MSG-43 RP-5 Red Hose, 1" NAD E10 +2/+12/5 Done-RAJ

MSG-44 RP-5 Red Hose, 1/2" NAD E10 +3/+12/5 Done-RAJ

MSG-45 RP-5 Hose, 7/8" NAD E10 +5/+12/5 Done-RAJ

MSG-46 RP-5 Pump Diaphragm Gland NAD E10 +1/+10/5 Done-RAJ

MSG-47 RP-5 Pump Diaphragm Gland NAD E10 +1/+6/5 Done-RAJ

MSG-48 RP-5 Red Hose, 3/8" NAD E10 +5/+6/1 Done-RAJ

MSG-49 RP-5 Green Gasket Material NAD H11 +8/-2/6 Done-RAJ

MSG-50 RP-5 Rigid Gasket, 10" 8% Chrysotile

H9 0/-10/2 1 Done-RAJ

MSG-51 RP-5 Packing Rope, 1/4" 65% Chrysotile

H13 -2/-2/1 5 Done-RAJ

MSG-52 RP-5 Rope Gasket, 1/4" NAD H14 -2/-12/4 Done-RAJ

MSG-53 RP-5 Pipe Insulation, 4" NAD N17 0/-4/24 Done-RAJ

MSG-54 RP-5 Old Conveyor Belt Patch NAD Location on Map Done-RAJ

MSG-55 MSG-56 MSG-57

RP-5 Pipe Insulation, 6" NAD E17 -1/-4/5E17 -1/-4/3E17 -1/-4/1

Done-RAJ

RP-5 Brake Shoes Assumed 3 Done-RAJ

RP-5 Shelves L8 to L9 Assumed 1 Done-RAJ

RP-5 Mud Joints Assumed 5 Done-RAJ

PLG-01 RP-6 2'x4' Ceiling Tile NAD Tool Room Done-RAJ

PLG-02 RP-6 2'x4' Insulation Tile NAD SEE MAP Done-RAJ

PLG-03 RP-6 Air Duct Wrap NAD Tool Room SEE MAP Done-RAJ

PLG-04 RP-6 2'x4' Fissured Ceiling Tile NAD Lunch Rm. SEE MAP Done-RAJ

PLG-05 RP-6 1'x1' Ceiling Tiles with Holes

NAD Lunch Rm. SEE MAP Done-RAJ

PLG-06 RP-6 2'x4' Smooth Ceiling Tiles NAD Hallway SEE MAP Done-RAJ

PLG-07 PLG-08PLG-09

RP-6 Pipe Insulation, 2" NAD Hall to OfficeMechanical RoomMechanical Room

Done-RAJ

PLG-10 RP-6 New Dry Wall NAD Mech. Rm. SEE MAP Done-RAJ

PLG-11 RP-6 Dry Wall Tape Joint NAD Mech. Rm. SEE MAP Done-RAJ

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

PLG-12 RP-6 Old Dry Wall NAD Mech. Rm. SEE MAP Done-RAJ

PLG-13 RP-6 Wall Plaster NAD Mech. Rm. SEE MAP Done-RAJ

PLG-14 RP-6 Air Duct Expansion Joint NAD Mech. Rm. SEE MAP Done-RAJ

PLG-15PLG-16PLG-17

RP-6 Pipe Insulation, 1 1/2" NAD N. Wall 2nd E/W +3N. Wall 2nd E/W +5N. Wall 2nd E/W +9

Done-RAJ

PLG-18 RP-6 Old Felt Paper NAD N/S2 E/W4 -2/0/4 Done-RAJ

PLG-19 RP-6 Cloth Wrap NAD N/S2 E/W4 -2/0/4 Done-RAJ

PLG-20 RP-6 Green Conveyor Belt NAD N/S2 E/W4 -1/0/4 Done-RAJ

PLG-21 RP-6 Grooved Conveyor Belt NAD N/S2 E/W4 -8/0/1 Done-RAJ

PLG-22 RP-6 Gasket NAD N/S2 E/W4 -10/0/1 Done-RAJ

PLG-23 RP-6 Yellow Flex Hose, 1 1/2" NAD N/S1 E/W8 -2/-2/1 Done-RAJ

PLG-24 RP-6 Insulator Blocks NAD N/S2 E/W6 -12/-10/2 Done-RAJ

PLG-25 RP-6 Rigid Fiber Gasket NAD N/S8 E/W6 -8/+8/3 Done-RAJ

PLG-26 RP-6 Soft, White Gasket NAD N/S19 E/W6 -8/+2/4 Done-RAJ

PLG-27 RP-6 Red, Ring Gasket NAD N/S19 E/W6 -14/-2/4 Done-RAJ

PLG-28 RP-6 Tan, Rigid Gasket 15% Chrysotile

N/S10 E/W6 0/0/6 5 Done-RAJ

PLG-29PLG-30 PLG-31

RP-6 RP-6 RP-6

Pipe Insulation, 1 1/4" NAD N/S7 E/W6 -1/0/12N/S7 E/W6 -4/0/20N/S7 E/W6 -8/0/20

Done-RAJ

PLG-32 PLG-33 PLG-34

RP-6 RP-6 RP-6

Pipe Insulation, 2" NAD N/S4 E/W6 -1/0/10N/S4 E/W6 -1/0/20N/S4 E/W6 -8/0/24

Done-RAJ

PLG-35 PLG-36 PLG-37

RP-6 RP-6 RP-6

Pipe Insulation, 3" NAD N/S3 E/W8 -1/0/24N/S3 E/W8 -1/+4/24N/S3 E/W8 -2/-12/24

Done-RAJ

PLG-38 PLG-39 PLG-40

RP-6 RP-6 RP-6

Pipe Insulation, 10" NAD N/S1 E/W6 -10/0/24N/S3 E/W6 -5/0/24 N/S1 E/W6 -2/0/22

Done-RAJ

PLG-41 PLG-42 PLG-43

RP-6 RP-6 RP-6

Pipe Insulation, 2 1/2" NAD N/S3 E/W1 -12/0/22N/S3 E/W2 +12/+18/24N/S3 E/W3 -18/+18/24

Done-RAJ

PLG-44 PLG-45 PLG-46

RP-6 RP-6 RP-6

Pipe Insulation, 6" NAD N/S6 E/W1 +2/-17/24N/S6 E/W2 +2/-10/24N/S6 E/W3 +2/+5/24

Done-RAJ

PLG-47 PLG-48 PLG-49

RP-6 RP-6 RP-6

Pipe Insulation, 2 1/2" 5% Chrysotile

N/S15 E/W2 -8/+3/6N/S15 E/W2 -10/+3/6N/S15 E/W2 -8/+3/15

2 Done-RAJ

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

PLG-50PLG-51 PLG-52

RP-6 RP-6 RP-6

Pipe Insulation, 1" NAD S. Ent. W. Corner +12S. Ent. W. Corner +9S. Ent. W. Corner +0

Done-RAJ

PLG-53 RP-6 Conveyor Belt/ Door-air Stop

NAD S. Entr. Door Bottom Done-RAJ

PLG-54 RP-6 Expanded Foam Insulation NAD N/S10 E/W1 -12/0/4 Done-RAJ

PLG-55 RP-6 Spun Wool NAD Heated Room Done-RAJ

PLG-56 RP-6 Building Insulation NAD N/S7 E/W1 -8/0/5 Done-RAJ

PLG-57 RP-6 Wall Board NAD N/S4 E/W1 -12/0/4 Done-RAJ

RP-6 12"x12" Black Floor Tile Assumed 1 Done-RAJ

PRG-01 RP-18 2'x4' Ceiling Tile Fissured NAD Lunch Rm. Central Off.

PRG-02 RP-18 Drywall (Movable Wall Partition)

NAD Lunch Rm. Central Off.

PRG-03 RP-18 Drywall Mud Joint NAD Wash Room Tech. Off.

PRG-04 RP-18 Drywall - Old NAD Wash Room Tech. Off.

PRG-05 RP-18 1'x2' Suspended Ceiling Tile

NAD Restroom Tech. Off.

PRG-06 RP-18 Mechanical Room Drywall NAD Mech. Rm. Tech. Off.

PRG-07 RP-18 1/2" Copper Pipe w/Insulation

NAD Mech. Rm. Tech. Off.

PRG-08 RP-18 Building Insulation NAD Exterior Mech. Room

PRG-09 PRG-10 PRG-11

RP-18 RP-18 RP-18

1" Pipe w/Insulation NAD W. Offices Mech Rm.W. Offices Mech Rm.W. Offices Mech Rm.

PRG-12 RP-18 Drywall NAD Mechanical Room

PRG-13 RP-18 Drywall-Tape Joint 5% Chrysotile

Mech. Rm. Central Off. 5

PRG-14 RP-19 2'x4' Ceiling Tile, Smooth NAD SEE MAP

PRG-15 RP-19 Insulation Wrap On Electrical Lines

NAD E1 +70/0/6

PRG-16 RP-19 1 1/2" Pipe w/Insulation NAD W. Bet. Potline 3B & 4A

PRG-17 RP-19 1" Pipe w/Insulation NAD W. Bet. Potline 3B & 4A

PRG-18PRG-19PRG-20

RP-22 RP-22 RP-24

1 1/4" Pipe Insulation NAD E. Bet. Potline 2A & 1B E. Bet. Potline 2A & 1BE. Bet. Potline 2A & 1B

PRG-21 RP-22 Duct Wrap NAD Tool Room

PRG-22 RP-21 2'x2' Ceiling Tile, Fissured NAD Lunch Rm. W. Tool Rm.

PRG-23 RP-21 1/8" Packing Gasket 70% Chrysotile

E. Tool Rm. - Storage 5

PRG-24 RP-23 Rigid Wall Board Insulation NAD 1A & 1B W. Cross Over

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

PRG-25 RP-23 Conveyor Belt NAD 1A West Heater

RP-23 12"x12" Floor Tile, Black Assumed 5

RP-23 9"x9" Floor Tile, Green Assumed 5

RP-23 12"x12" Floor Tile, Pink/Tan

Assumed 1

RP-23 24"x24" Floor Tile, White Assumed 1

RP-23 12"x12" Floor Tile, Tan Assumed 1

PRO-1 Mineral 11-13% Non-Fibrous 87-89%, White, Mudded Fitting

Non Detected

Pot Room Office

QH-01 RP-40 2" x 4" Ceiling tile NAD Office Area Up 8

RP-40 12"x12" Floor Tile, Black Assumed 1 Done-RAJ

RBH-01 RBH-02 RBH-03

RP-25 RP-25 RP-25

Pipe Insulation, 18" NAD See Map, Up 7 See Map, Up 12 See Map, Up 12

RBH-04 RBH-05 RBH-06

RP-25 RP-25 RP-25

Pipe Insulation, 3" NAD See Map, Up 12 See Map, Up 12 See Map, Up 10

RBH-07 RBH-08 RBH-09

RP-25 RP-25 RP-25

Pipe Insulation, Steam Line NAD See Map, Up 10 See Map, Up 6 See Map, Up 10

RBH-10 RBH-11 RBH-12

RP-25 RP-25 RP-25

Pipe Insulation, Condensate Line

NAD See Map, Up 10 See Map, Up 10 See Map, Up 10

RBH-13 RBH-14 RBH-15

RP-25 RP-25 RP-25

Pipe Insulation, 2" NAD See Map, Up 15 See Map, Up 15 See Map, Up 6

RBH-16 RBH-17 RBH-18

RP-25 RP-25 RP-25

Pipe Insulation, Small Domestic Water

NAD See Map, Up 10 See Map, Up 10 See Map, Up 12

RBH-19 RBH-20 RBH-21

RP-25 RP-25 RP-25

Pipe Insulation, Large Domestic Water

NAD See Map, Up 1 See Map, Up 6 See Map, Up 10

RBH-22 RP-25 2'x4' Drop Ceiling Tile NAD See Map, Up 10

RBH-23 RBH-24

RP-25 RP-25

Dry Wall and Joint NAD See Map, Up 4 See Map, Up 7

RBH-25 RP-25 2'x4' Drop Ceiling Tile NAD See Map, Up 10

RBH-26 RP-25 Duct Wrap NAD See Map, Up 6

RBH-27 RP-25 Vibration Damper NAD See Map, Up 7

RBH-28 RBH-29 RBH-30

RP-25 RP-25 RP-25

Pipe Insulation Wrap, 28 Westinghouse, Lines 3 and 4

5% Chrysotile, about 20 ft. per unit

Rectifier #31A Rectifier #37B Rectifier #47B

1

RBH-31 RP-25 Fire Blanket NAD South East Corner of Basement

RP-25 9"x9" Grey Floor Tile Assumed 4 Gone

RP-25 Arc Shoots Assumed 2 Qty 56

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

RP-25 12"x12" Black Floor Tile Assumed 1 Non Asbestos

RP-25 Mud Joints Assumed 1

RCHH-01 RP-2 2'x4' Drop Ceiling Tile NAD SEE MAP Done-RAJ

RP-2 12"x12" Black Floor Tile Assumed 1 Done-RAJ

RCTG-01 RCTG-02 RCTG-03

RP-43 RP-43 RP-43

Pipe Insulation, 3" NAD SEE MAP SEE MAP SEE MAP

Done-RAJ

RCTG-04 RP-43 Pipe Paint, 3" NAD SEE MAP Done-RAJ

RCTG-05 RCTG-06

RP-43 RP-43

Pipe Insulation, 12" NAD SEE MAP SEE MAP

Done-RAJ

RCTG-07 RCTG-08 RCTG-09

RP-43 RP-43 RP-43

Fan Shroud NAD SEE MAP SEE MAP SEE MAP

Done-RAJ

REBH-01 REBH-02 REBH-03

RP-1 RP-1 RP-1

Pipe Insulation, 1" NAD Mechanical Room Mechanical Room Mechanical Room

Done-RAJ

REBH-04 REBH-05 REBH-06

RP-1 RP-1 RP-1

Pipe Insulation, 2" NAD Mechanical Room Mechanical Room Mechanical Room

Done-RAJ

REBH-07 REBH-08 REBH-09

RP-1 RP-1 RP-1

Pipe Joint Insulation NAD Mechanical Room Mechanical Room Mechanical Room

Done-RAJ

REBH-10 RP-1 Vibration Damper NAD Mechanical Room Done-RAJ

REBH-11 RP-1 Duct Wrap NAD Mechanical Room Done-RAJ

REBH-12 REBH-13

RP-1RP-1

Domestic Water Line, 1" NAD Jan. Clst. Men's Rstrm Jan. Clst. Men's Rstrm

Done-RAJ

REBH-14 RP-1 Pipe Insulation, 2" NAD Janitor Closet Up 12 Done-RAJ

REBH-15 RP-1 Domestic Water Line, 1" NAD Jan. Clst. Men's Restrm Done-RAJ

REBH-16 REBH-17

RP-1RP-1

Pipe Insulation, 2" NAD Janitor Closet Up 12Janitor Closet Up 12

Done-RAJ

REBH-18 RP-1 Dry Wall NAD Mechanical Room Done-RAJ

REBH-19 RP-1 Dry Wall Compound NAD Mechanical Room Done-RAJ

REBH-20 RP-1 2'x4' Drop Ceiling Tile NAD Dwg. File Room Done-RAJ

RP-1 9"x9" Floor Tile, Tan Assumed 4 Done-RAJ

RP-1 Mud Joints Assumed 1 Done-RAJ

RP-1 1'x1' Grey Floor Tile Assumed 1 Done-RAJ

RH-01 RP-23 Pipe Insulation NAD E2, North Wall, Up 30

RH-02 RP-24 Storage Pipe and Insulation Debris

NAD E23, North Side, Up 15

RH-03RH-04 RH-05

RP-24 RP-24 RP-24

Pipe Insulation, Steam Pipe

25% Chrysotile

E29, North Side Up 7 E29, Center Up 40 E29, Center Up 40

5 not there

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

RH-06 RP-23 2'x4' Ceiling Tile NAD E21, South Side, Up 8

RH-07 RH-08 RH-09

RP-23 RP-23 RP-23

Pipe Insulation NAD E19 +9 S.Wall Up11 E19 +9 S.Wall Up 13E19 +9 S.Wall Up 11

RH-10 RH-11

RP-23 RP-23

Dry Wall and Joint Material NAD E19 +15 S.Wall Up 4E19 +13 S.Wall Up 10

RH-12 RP-23 2'x4' Ceiling Tile NAD Office E19 S. Wall Up 8

RH-13 RP-23 2'x4' Ceiling Tile NAD Office E19 S. Wall Up 8

RH-14 RP-23 2'x4' Ceiling Tile NAD SW Lunch Room Up 8

RH-15 RH-16 RH-17

RP-23 RP-23 RP-23

Pipe Insulation, 1 1/2" NAD SEE MAP SEE MAP SEE MAP

RH-18 RH-19

RP-23 RP-23

Pipe Insulation NAD E2, Center, Up 40 E2, South Wall, Up 40

RH-20 RH-21 RH-22

RP-23 RP-23 RP-23

Pipe Insulation, Steam Line NAD E2, Center, Up 40SEE MAP, Up 40 SEE MAP, Up 40

RH-23 RP-23 Vibration Damper NAD E13 +12N. -15 Up 35

RH-24 RP-23 Compressed Air Line Wrap 95% Chrysotile

SEE MAP 7 not found

RH-25 RP-23 Duct Wrap 95% Chrysotile

SEE MAP 5 not found

RH-26 RH-27 RH-28

RP-23 RP-23 RP-23

Pipe Insulation, 4" NAD SEE MAP SEE MAP SEE MAP

RP-23 12"x12" Black Floor Tile, Lunch Room

Assumed 5

RP-23 12"x12" Black Floor Tile Assumed 2

RP-23 12"x12" Black Floor Tile Assumed 2

RP-23 Mud Joints Assumed 2

RLBH-01 RLBH-02 RLBH-03

RP-23 RP-23 RP-23

Pipe Insulation, 1" NAD Mechanical RoomMechanical Room Mechanical Room

Done-RAJ

RLBH-04RLBH-05 RLBH-06

RP-3 RP-3 RP-3

Pipe Insulation, 2" NAD Mechanical RoomMechanical Room Mechanical Room

Done-RAJ

RLBH-07RLBH-08 RLBH-09

RP-3 RP-3 RP-3

Pipe Joint Compound 80% Chrysotile ABATED

Mechanical RoomMechanical Room Mechanical Room

2 Done-RAJ

RLBH-10RLBH-11 RLBH-12

RP-3 RP-3 RP-3

Pipe Joint Insulation NAD Mechanical RoomMechanical Room Mechanical Room

Done-RAJ

RLBH-13 RP-3 Vibration Damper NAD Mechanical Room Done-RAJ

RLBH-14 RP-3 Duct Wrap NAD Mechanical Room Done-RAJ

RLBH-15 RLBH-16 RLBH-17

RP-3 RP-3 RP-3

Steam Pipe Insulation, 1 1/2"

10% Amosite

Above Lab Closet Wet LabAbove Closet Wet LabAbove Closet Wet Lab

1 Done-RAJ

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

RLBH-18 RLBH-19RLBH-20

RP-3 RP-3 RP-3

Domestic Water Line, Insulation 3/4"

7% Amosite17 FT. APROX.

Mechanical RoomPrep. Room Under Sink

1 Done-RAJ

RLBH-21RLBH-22RLBH-23

RP-3 RP-3 RP-3

Pipe Insulation NAD Carbon Prep. Room Carbon Prep. Room Carbon Prep. Room

Done-RAJ

RLBH-24 RP-3 1'x1' Ceiling Tile NAD Wet Lab Done-RAJ

RLBH-25 RP-3 2'x4' Ceiling Tile NAD Wet Lab Done-RAJ

RLBH-26 RP-3 Lab Counter Tops 15% Chrysotile

Wet Lab 2 Done-RAJ

RLBH-27RLBH-28RLBH-29RLBH-30RLBH-31

RP-3RP-3RP-3RP-3RP-3

Wall Plaster NAD Air Control RoomI.H. RoomEnvironmental RoomIron Sample RoomSample Prep Room

Done-RAJ

RLBH-32RLBH-33

RP-3 RP-3

Dry Wall Compound NAD Tony Ross Off. CompChemical Storage Drywall

Done-RAJ

RP-3 Transit Fume Hoods Assumed 2 Done-RAJ

RP-3 4900 sq. ft. 9"x9" Floor Tile

Assumed 2 Done-RAJ

RP-3 Mud Joints Assumed 1 Done-RAJ

RP-3 Mud Joints, 3/4" Assumed 1 Done-RAJ

RP-3 Mud Joints, 1 1/2" Assumed 1 Done-RAJ

RP-3 12"x12" Floor Tile, Black Assumed 1 Done-RAJ

ROBH-01 RP-2 Pipe Insulation, 1" NAD Mechanical Room Done-RAJ

ROBH-02ROBH-03

RP-2 RP-2

Pipe Insulation, 2" NAD Mechanical Room Mechanical Room

Done-RAJ

ROBH-04 RP-2 Duct Wrap NAD Mechanical Room Done-RAJ

ROBH-05 RP-2 Vibration Damper NAD Mechanical Room Done-RAJ

ROBH-06 RP-2 Dry Wall NAD Mechanical Room Done-RAJ

ROBH-07ROBH-08

RP-2RP-2

Pipe Insulation, 1" NAD Mechanical RoomMechanical Room

Done-RAJ

ROBH-09 RP-2 Pipe Insulation, 2" NAD Mechanical Room Done-RAJ

ROBH-10 ROBH-11 ROBH-12

RP-2 RP-2 RP-2

Pipe Joints NAD Mechanical RoomMechanical Room Mechanical Room

Done-RAJ

ROBH-13ROBH-14 ROBH-15

RP-2 RP-2 RP-2

Pipe Joints Insulation NAD Mechanical RoomMechanical Room Mechanical Room

Done-RAJ

ROBH-16 ROBH-17 ROBH-18

RP-2 RP-2 RP-2

Hot Water Tank Insulation NAD Mechanical RoomMechanical Room Mechanical Room

Done-RAJ

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

ROBH-20 RP-2 Dry Wall NAD Janitor's Closet Done-RAJ

RP-2 1'x1' Ceiling Tile NAD Conference Room Done-RAJ

ROBH-21 RP-2 1" Domestic Water Line NAD Janitor's Closet Done-RAJ

RP-2 9"x9" Grey Floor Tile Assumed 4 Done-RAJ

RP-2 1'x1' Floor Tile, Light Grey Assumed 1 Done-RAJ

RP-2 Mud Joint Assumed 1 Done-RAJ

RP-2 Pipe Joints Assumed 1 Done-RAJ

RPHH-01RPHH-02 RPHH-03

RP-28 RP-28 RP-28

Pipe Insulation NAD At Pumps, Up 2At Pumps, Up 2At Pumps, Up 1

RPHH-04 RPHH-05 RPHH-06

RP-28 RP-28 RP-28

Pipe Insulation NAD NW Side at HeaterCenter of Bldg. S. End at Heater

RPHH-07 RPHH-08 RPHH-09

RP-28 RP-28 RP-28

Pipe Insulation, Condensate Line

35% Amosite

NW Corner, Up 14NW Corner, Up 14 NW Corner

2

RPHH-10 RPHH-11 RPHH-12

RP-28 RP-28 RP-28

Pipe Insulation, Steam Line 35% Amosite

NW Corner NW Corner NW Corner

2

RPHH-13 RPHH-14 RPHH-15

RP-28 RP-28 RP-28

Insulation Joints on Water Line

NAD At Pumps in Center At Pumps in Center At Pumps in Center

RP-28 Mud Joints (2) Assumed 5

RP-28 Mud Joints (9) Assumed 2

RUH-01 RP-33 2'x4' Ceiling Tile NAD Old Office Up 8 Done-RAJ

RUH-02 RUH-03

RP-33 RP-33

Dry Wall NAD Old Off. Up 4 Comp.Old Off. Up 4 Drywall

Done-RAJ

RUH-04 RP-33 Wall Insulation NAD Old Office Done-RAJ

RP-33 12"x12" Floor Tile Assumed 1 Done-RAJ

S20G-01 RP-38 Roof Mastic NAD SEE MAP Done-RAJ

SP-01 RP-37 Pipe Insulation NAD SEE MAP

SP-02 RP-37 1" Pipe Insulation NAD W of AU1 Pitch Pump

SP-03 RP-37 3" Pipe Insulation NAD W of AU1 Pitch Pump

SP-04 SP-05

RP-37RP-37

1" Pipe Insulation NAD A64120-AU2 STM ValveN of AU2 Pitch Pump

SP-06SP-07

RP-37RP-37

3" Pipe Insulation NAD N of AU2 Pitch Pump N of AU2 Pitch Pump

SP-08 RP-37 Flange Gasket Material 45% Chrysotile

N of AU2 Pitch Pump 5

SP-09SP-10

RP-37RP-37

Pipe Insulation, 3 1/2" NAD See Map, Up 3 See Map, Up 14

SP-11 SP-12 SP-13

RP-37RP-37 RP-37

Pipe Cloth Wrap, 2 1/2" NAD S. Line, E. Tank N. Line, E. Tank N. Line, W. Tank

SP-14 RP-37 Caulking Material 2% Chrysotile

West Tank 5

SP-15 SP-16 SP-17

RP-37RP-37 RP-37

Felt Paper Pipe Wrap 15% Chrysotile

S. of East TankS. of East Tank Edge of East Pit

4

Sample ID Sheet # Description

% and Typeof

AsbestosLocation

ConditionRank

Status

SP-17ASP-18A

RP-37RP-37

Caulking NAD See Map See Map

SP-18 RP-37 2 1/2" Pipe Insulation NAD East Side of East Pit

SP-20 SP-21 SP-22

RP-37RP-37 RP-37

Pipe Joint Insulation, 1" NAD See MapSee MapSee Map

SP-23 SP-24 SP-25

RP-37RP-37 RP-37

Pipe Joint Insulation, 3" NAD See MapSee MapSee Map

ULH-01 RP-34 2'x4' Drop Ceiling NAD Lunch Room Done-RAJ

RP-34 12"x12" Black Floor Tile, Unloading Control Building

Assumed 7 Done-RAJ

RP-34 12"x12" Black Floor Tile, Lunch Room and Restroom

Assumed 1 Done-RAJ