et_nit_2122_28.pdf - IIT Kharagpur

66
INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR KHARAGPUR, WEST BENGAL 721302 TENDER DOCUMENT for Construction of Shallow and Deep Water Maneuvering and Seakeeping Basin Facility for Ocean Engineering and Naval Architecture Department. NIT No. IW/CE/NIT/2021-22/028 Tender Serial No. ______________________________Issued to: …………………………………………………..…………………..…………………..………… ………………………………………………………..……………..…………………..………… …………………………………………………………..…………..…………………..…………

Transcript of et_nit_2122_28.pdf - IIT Kharagpur

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR

KHARAGPUR, WEST BENGAL 721302

TENDER DOCUMENT

for

Construction of Shallow and Deep Water Maneuvering and Seakeeping Basin Facility for Ocean Engineering and Naval

Architecture Department.

NIT No. IW/CE/NIT/2021-22/028

Tender Serial No. ______________________________Issued to:

…………………………………………………..…………………..…………………..…………

………………………………………………………..……………..…………………..…………

…………………………………………………………..…………..…………………..…………

Page | 1

Contents

1. NOTICE INVITING TENDER 2

1.1. INTRODUCTION ......................................................................................................................................................................................... 2

1.2. PARTICULARS ............................................................................................................................................................................................. 2

1.3. ELIGIBILITY CRITERIA ................................................................................................................................................................................. 2

2. INFORMATION TO BIDDERS 4

2.1. SCOPE OF WORK ........................................................................................................................................................................................ 4

2.2. GENERAL INSTRUCTIONS .......................................................................................................................................................................... 4

2.3. SUBMISSION OF TENDER .......................................................................................................................................................................... 7

2.4. EVALUATION OF BIDS AND AWARD OF WORK ........................................................................................................................................ 7

2.5. BIDDING CAPACITY OF CONTRACTORS…………………………………………………………………………………………………………..8

3. UNDERTAKING BY THE BIDDER 9

Annexure(s)…………………………………………………………………………………………………………………………………………….10-15

4. Checklist for Documents to be uploaded on https://eprocure.gov.in/eprocure/app………………………16

PRICE BID (SOQ)…………………………………………………………………………………………………………………………………… 17-65

Page | 2

1. NOTICE INVITING TENDER

1.1. INTRODUCTION

Indian Institute of Technology (IIT) Kharagpur, hereinafter called IITKGP, invites online tenders from the eligible contractors for Construction of Shallow and Deep Water Maneuvering and Sea keeping Basin Facility at IIT Kharagpur. Particulars of the project are as following.

1.2. PARTICULARS

1.NIT Number NIT No. IW/CE/NIT/2021-22/028

2.Name of Work Construction of Shallow and Deep Water Maneuvering and Sea keeping Basin Facility at IIT Kharagpur

3.Location of Work

Adjoining Ocean Engineering and Naval Architecture department building and Hydrodynamics Laboratory, IIT Kharagpur

4.Estimated Cost(including GST) ₹ 20,47,97,150/- (Rupees Twenty Crore Forty-Seven Lakhs Ninety-Seven Thousand One Hundred and Fifty Only).

5.Earnest Money Deposit NSIC/MSEs Registration Certificate OR Bid Security Declaration Form (Annexure-III).

6.Time Limit for Execution 540 days from Date of Start.

7.Tender Basis and Mode Two stage(Technical Bid & Financial Bid)

8.Date, Time & Venue of Pre-bid Meeting 21.10.2021, 15:00hrs, CCM Meeting Room, 1stFl, Old Bldg., IIT Kharagpur, Kharagpur-721302

9.Closing Date & Time for Receipt of bids 28.10.2021 upto 15:00hrs

10.Date& Time for Opening of Technical Bid 29.10.2021 at 15:30hrs

11.Date& Time for Opening of Price Bid To be intimated to the eligible bidders subsequently.

12. Engineer-in-charge and contact details.

Mr. S K Biswas, Sr. Executive Engineer(Civil) Tel No. 03222-282580, Mobile No. 74071 39556 Email: [email protected]

13. Address for tender issue, submission and opening

Civil Construction & Maintenance Section, 1st Floor, Old Building, IIT Kharagpur, Kharagpur WB 721302

14.Website for full and updated information http://www1.iitkgp.ac.in/topfiles/tenders.php;

https://eprocure.gov.in/eprocure/app

15. Website for tender submission & processing

https://eprocure.gov.in/eprocure/app

1.3. ELIGIBILITY CRITERIA

1.3.1. The bidder must be registered in appropriate class of works with Government organization like CPWD/ PWD/ MES or PSUs or those having experience in similar nature of works awarded by Government / Semi Government Organizations/ Government Funded Autonomous Organization / Public Limited Company.

Page | 3

1.3.2. The bidder must have done at least 1 (ONE) similar work of value of 80% (i.e Rs.16,38,37,720) of the estimated cost or 2 (TWO) similar works for projects each of value 60% (i.e Rs.12,28,78,290) of the estimated cost or 3 (THREE) similar work for projects each of value 40% (i.e Rs.8,19,18,860) of the estimated cost with Government/ Semi-government/PSU/ Government Funded Autonomous Organization during last 7 (seven) years preceding last date of the month of tender submission.

Note:

(i) The estimated is ₹ 20,47,97,150/- (Rupees Twenty Crore Forty-Seven Lakhs Ninety-Seven Thousand One Hundred and Fifty Only).

(ii) The value of executed works shall be brought to current costing level by enhancing the actual value of work at simple rate of 7% per annum; calculated from the date of completion to the last date of receipt of applications for tender.

(iii) Similar work shall consist of :

Any RCC construction with RCC basement OR Industrial Shed with RCC basement.

1.3.3. The bidder must be registered with appropriate government authority as a bona-fide business entity and must have GST registration certificate and Permanent Account Number of income tax.

1.3.4. The registrations and licenses should be valid during the execution phase.

1.3.5. The Average annual turnover of the bidder as per ITCC or profit & loss statement shall not be less than 30% of the estimated cost of project, not having incurred loss in more than two years, during last 5 years ending 31 Mar 2020. The documents submitted should be duly certified and audited by Chartered Accountant.

1.3.6. Net worth Certificate as on 31.03.2020 of minimum 15% of the estimated cost i.e. Rs. 3.08 Crore issued by certified Chartered Accountants is to be submitted. Format for the same is enclosed in Annexure-IV.

Chief Engineer

On behalf of the Director, Indian Institute of Technology Kharagpur

Copy to: 1) Registrar 2) S.E (E&M) 3) Sr. Executive Engineer (Civil/E&M) 4) Assistant / Junior Engineer (Civil/ E&M) 5) Notice Board

6) Office file

Sd/-

Page | 4

2.INFORMATION TO BIDDERS

2.1 SCOPE OF WORK

2.1.1 The IITKGP intends to construct a Shallow and Deep Water Maneuvering and Seakeeping Basin Facility at IIT Kharagpur. The construction work of this facility shall include civil, structural, plumbing and sanitation, electrical (HT & LT), ELV, HVAC, water transfer system, filtration system, fire protection and other piping works. It may be noted that deep excavation up to around 6 m below existing ground level as well as some piling work will be required to be carried out. It may be also noted that water table at the site of construction is generally quite high, being under 1 m below the existing ground in the rainy season to about 3 m below in the fair season.

2.1.2 Constraint: The job needs to be executed in IIT campus area without causing any disturbances to the normal functioning of routine activities/ road networks. Deep excavation needs to be carried out in close proximity to existing buildings and their foundations.

2.1.3 The vendor shall work out execution sequence and methodology so as to complete the project within the envisaged time and the estimated cost, duly handling the constraint mentioned above.

2.2 GENERAL INSTRUCTIONS

2.2.1 Bidding documents are to be obtained electronically through websites: http://www1.iitkgp.ac.in/topfiles/tenders.php; ii)https://eprocure.gov.in/eprocure/app

2.2.2 This bid document shall be read in conjunction with GCC (General Conditions of Contract) available on http://www1.iitkgp.ac.in/topfiles/tenders.php.

2.2.3 The bidder shall visit and inspect the site and obtain all information on his own responsibility and at own cost, which may be necessary for the purpose of quoting and submitting the tender. No excuse or ignorance as to site conditions and local information shall be accepted after awarding of the contract. Access to the site will be granted by the Engineer-in-charge on all working days within working hours.

2.2.4 IITKGP shall not provide any space at site for labour hutments.

2.2.5 All clarifications about the tender shall be sought by bidder on or before pre-bid meeting. The bidders may make suggestions which shall be considered during the Pre Bid Meeting. Intending bidder(s) may also send their queries or suggestion, if any, through e-mail to the Engineer-in-charge [email protected] or before 21.10.2021, 14:30 hrs. No queries shall be entertained after notification of replies to noteworthy queries received till the date of pre-bid meeting.

2.2.6 Completion certificate issued by Competent Authority will only be considered as credential. If the Completion certificate issued by Competent Authority does not reflect the type of work, then Final bill / Schedule of Quantity of the qualifying works also to be attached along with the Completion certificates. Certificate from private individuals / organizations for whom such works have been executed shall not be accepted.

2.2.7 The bidding document (consisting of specifications, the schedule of quantities of various types of items to be executed, the set of terms and conditions of the contract and other documents / drawings, if any), Addendum/Corrigenda, Clarifications to Pre-bid queries can be downloaded from the websites: i)http://www1.iitkgp.ac.in/topfiles/tenders.php; iii)https://eprocure.gov.in/eprocure/app. Corrigenda, if any shall be published only on these websites at any time before the closing time of tender. The institute shall not be responsible for any delay / difficulties / inaccessibility of downloading facility for any reason whatsoever. The tenderers who have downloaded the tender documents from website must visit the website and ensure that such addendum(s)/corrigendum(s) (if any) is also downloaded by them. This shall be the responsibility of the prospective registered bidders to check the web site for any such corrigendum/addendum before closing time of tender and ensure that bid submitted by them are in accordance with all the corrigendum’s/addendums.

2.2.8 All costs, charges & expenses that may be incurred in connection with the preparation of his tender shall be borne by him and the Institute accepts no liability whatsoever therefore.

2.2.9 Rates quoted by the bidders shall be inclusive of GST (Goods and Services Tax - Central, State and Interstate) and all applicable taxes. Income Tax and all other statutory deductions like labour cess etc. will be deducted from the bill as per prevailing rules.

2.2.10 Exemption to IITKGP against any tax/ duty/ fee/ surcharge/ charge/ cost, if any, found applicable or sought later from IITKGP after award shall be passed on to IITKGP by the contractor without dispute.

Page | 5

2.2.11 IITKGP reserves the right to reject any or all of the bids without assigning any reason.

2.2.12 Bid Validity: Bid shall remain valid for 120 days from the date of submission.

2.2.13 Firm Price: Bidder’s quoted Rates/Prices for executing the activities under the Contract shall remain firm till completion of the entire work & shall not attract any escalation under any circumstances whatsoever.

2.2.14 If any information furnished by the bidder is found as false / fabricated, then his bid will be rejected and treated as cancelled. Even if such manipulation is detected at any stage after signing of the contract, it would lead to termination of the contract besides enforcing actions as mentioned in the Bid Security Declaration Form(Annexure-III) and liabilities towards prosecution. In such cases the bidder will be debarred from participation in future tendering process in IITKGP for next 01 (One) year.

2.2.15 Earnest Money Deposit(EMD): As per amendment in GRF-2017, No.F9/4/2020-PPD dated 12.11.2020, no provision for EMD has been kept in this tender. However the bidder has to submit a Bid Security Declaration as per Annexure-III.MSEs registered with District Industries Centers, National Small Industries Corporation and any other body specified by Ministry of MSME or Startups as recognized by Department of Industrial Policy and Promotion shall be exempted from payment of EMD in the bid. The self attested photocopy of their evidence should be submitted by the bidder(s) along with the formal request letter for exemption.

2.2.15.1 In case the NSIC/MSEs registration certificate is found invalid during evaluation, the bid of such bidder shall be rejected.

2.2.15.2 Bidder so exempted for submission of EMD shall have to submit an undertaking as per Annexure-II.

2.2.15.3 Bidder not having NSIC/MSEs registration has to submit Bid Security Declaration Form (Annexure-III) alongwith an undertaking as per Annexure-II.

2.2.16 Defect liability period will be 5 years from date of completion.

2.2.17 Security deposit of 5% will be released @ 1% p.a on satisfactory/ successful completion of any defect notified during the year/previous years.

2.2.18 General: Only Indian Manufacturers/Service provider or their authorized vendors, having registered office in India are invited to quote.

A. Compliance under Rule 144 (xi) of the General Financial Rules (GFRs) 2017

I. As per Ministry of Finance, Department of Expenditure, Public Procurement Division Order (Public Procurement No.1) issued from file No.6/18/2019-PPD dated 23rd July, 2020 & the Order issued from time to time regarding Restrictions under Rule 144 (xi) of the General Financial Rules (GFRs) 2017, it is directed that any bidder from a country which shares a land border with India will be eligible to bid in any procurement whether of goods, services (including consultancy services and non-consultancy services) or works (including turnkey projects) only if the bidder is registered with the Competent Authority i.e. the Department for Promotion of Industry and Internal Trade (DPIIT).

II. “Bidder” (including the term ‘tenderer’, ‘consultant’ or ‘service provider’ in certain contexts) means any person or firm or company, including any member of a consortium or joint venture (that is an association of several persons, or firms or companies), every artificial juridical person not falling in any of the descriptions of bidders stated hereinbefore, including any agency, branch or office controlled by such person, participated in a procurement process.

III. “Bidders from a country which shares a land border with India” for the purpose of this Order means:

a) An entity incorporated, established or registered in such a country; or

b) A subsidiary of an entity incorporated, established or registered in such a country; or

c) An entity substantially controlled through entities incorporated, established or registered in such a country;

or

d) An entity whose beneficial owner is situated in such a country; or

e) An Indian (or other) agent of such an entity; or

f) A natural person who is the citizen of such a country; or

Page | 6

g) A consortium or joint venture where any member of the consortium or joint venture falls under any of the

above

IV. The beneficial owner for the purpose of above will be as under: - (i) In case of a company or Limited Liability Partnership, the beneficial owner is the natural person(s), who,

whether acting alone or together, or through one or more juridical person, has a controlling ownership

interest or who exercise control through other means.

Explanation-

a) “Controlling ownership interest” means ownership of or entitlement to more than twenty-five per cent of

share or capital or profit of the company;

b) “Control” shall include the right to appoint majority of the directors or to control the management of

policy decisions including by virtue of their shareholding or management rights or shareholders

agreements or voting agreements;

(ii) In case of a partnership firm, the beneficial owner is the natural person (s) who, whether acting alone or

together, or through one or more juridical person, has ownership of entitlement to more than fifteen percent

of capital or profits of the partnership;

(iii) In case of an unincorporated association or body of individuals, the beneficial owner is the natural person(s),

who, whether acting alone or together, or through one or more juridical person, has ownership of or

entitlement to more than fifteen percent of the property or capital or profits of such association or body of

individuals;

(iv) Where no natural person is identified under (1) or (2) or (3) above, the beneficial owner is the relevant natural

person who holds the position of senior managing official;

(v) In case of a trust, the identification of beneficial owner(s) shall include identification of the author of the trust,

the trustee, the beneficiaries with fifteen percent or more interest in the trust and any other natural person

exercising ultimate effective control over the trust through a chain of control or ownership

V. An agent is a person employed to do any act for another, or to represent another in dealings with third person.

VI. For Works contracts, including Turnkey contracts, the successful bidder shall not be allowed to subcontract works to any contractor from a country which shares a land border with India unless such contractor is registered with the Competent Authority.

A certificate (duly filled & signed) shall be submitted by bidders in the tender documents regarding their compliance with the said order as per Annexure A. If the certificate submitted by a bidder whose bid is accepted is found to be false, this would be a ground for immediate termination and further legal action in accordance with law.

B. Compliance under Rule 153 (iii) of the General Financial Rules (GFRs) 2017

It is mandatory for bidders to quote items having 20% or more local content. Refer revised Public Procurement (Preference to Make in India), Order 2017 P-45021/2/2017-B.E-II dated 16.09.2020 and the order issued from time to time by Department for Promotion of Industry & Internal Trade (DPIIT), Ministry of Commerce and Industry, Government of India. (Submit duly filled Annexure B for the same).

Also, as per DPIIT, Ministry of Commerce and Industry OM vide no: P-45021/102/2019-BE-II-Part(1) (E-50310) dated 04.03.2021, bidders can’t claim themselves as Class-I local supplier / Class-II local supplier by claiming the services such as transportation, insurance, installation, commissioning, training and after sales service support like AMC/CMC etc. as local value addition.

Page | 7

2.3 SUBMISSION OF TENDER

2.3.1 Help for Contractors, FAQ, Information about DSC and Bidders Manual Kit containing the detailed guidelines for e-Procurement system are also available on Central Public Procurement Portal.[https://eprocure.gov.in/eprocure/app]

2.3.2 It is mandatory for all the bidders to have a valid Class-II/Class-III Digital Signature Certificate (in the name of person having power of attorney to sign the Bid) from any of the licensed Certifying Agency (Bidders can see the list of licensed CA’s from the link www.cca.gov.in) to participate in e-Procurement of IIT KHARAGPUR.

2.3.3 It is mandatory for the bidders to get their firm /company registered with e-procurement portal https:// eprocure.gov.in/eprocure/app to have user ID & password.

2.3.4 Tender documents will be available online on website https://eprocure.gov.in/eprocure/app which can be downloaded free of cost.

2.3.5 Bidders may download and refer the “Instructions for Online Bid Submission” from (https://eprocure.gov.in/eprocure/app;jsessionid=2A56E178EED5C7D8536175EFBB573C9F.eprocgep2?page=HelpForContractors&service=page).

2.3.6 The tender documents shall be submitted online in the prescribed format given on the websites and technical bids received online shall be opened as per NIT or Corrigendum thereof. No other mode of submission is acceptable. Detailed credentials as per the requirement of eligibility criteria and all tender papers except Bill of Quantities are to be submitted in “Technical Bid”.

Bill of Quantities with rates duly filled in are to be submitted in the format provided online in the name of “Financial Bid”. Hence, physical submission of the documents is limited to submission of MSE registration certificate as per provision given in sub-clause 1.2.5 of NIT & 2.2.15 of Information to Bidders.

Representative of the bidder, who chooses to attend, may attend the online opening of the technical bids on the scheduled date and time of Bid opening. However, such representatives shall be allowed to attend the opening of the Technical Bids, only, if such person presents the letter of authority issued in his name by the bidder on his letter head.

2.3.7 Bidders cannot submit the tender after the due date and time of e-bid submission. Time being displayed on Central Public Procurement Portal https://eprocure.gov.in/eprocure/app (“Server System Clock Time”) shall be final and binding on the bidder. e-Bids are required to be submitted by bidders, only as per the Indian Standard Time (IST) and not the time as per their location/country.

2.3.8 The bidders are advised to submit their e-bids well before the e-bid due date. IIT KHARAGPUR shall not be responsible for any delay in submission of e-bids for any reason including server and technical problems.

2.3.9 The Technical and Financial Bid shall be digitally signed by the Authorized Signatory of the bidder & submitted “on-line” only. The authorized signatory of the bidder must be in possession of Power of Attorney before submitting the digitally signed bid. Scanned copies of various documents can be prepared in .pdf file format.

2.3.10 Any tender received without original Earnest Money in the form as specified in clause 1.2.5 of tender documents shall not be considered and shall be summarily rejected.

2.3.11 IIT KHARAGPUR reserves the right to cancel the tenders before submission/opening of tenders, postpone the tender submission/opening date and to accept/reject any or all tenders without assigning any reasons thereof. IIT KHARAGPUR’s assessment of suitability as per eligibility criteria shall be final and binding.

2.3.12 Tenderers may note that they are liable to be disqualified at any time during tendering process in case any of the information furnished by them is not found to be true. The decision of IIT KHARAGPUR in this regard shall be final and binding.

2.4 EVALUATION OF BIDS AND AWARD OF WORK

2.4.1 The Bid of bidder will be opened electronically on the specified date and time of opening at the Civil Construction & Maintenance Section, 1st Floor, Old Building, IIT Kharagpur, Kharagpur WB 721302 in the presence of willing bidders or their authorized representatives.

2.4.2 Date, time and place of opening of Financial Bid will be informed after evaluation of Technical Bid to the Technically Qualified Bidders.

Page | 8

2.4.3 Bids shall, first, be checked for NSIC/MSEs registration certificate or Bid Security Declaration Form (Annexure-III). Only those bids found to have duly submitted NSIC/MSEs registration certificate or Bid Security Declaration Form (Annexure-III) shall be considered for evaluation.

2.4.4 Evaluation of Technical Bid: The bids received will then be assessed on the eligibility criteria mentioned at Para1.3of Notice Inviting Tender. Bids found not meeting the eligibility criteria shall be considered non-responsive and shall be rejected summarily.

2.4.5 IITKGP retains the right to revert back to individual bidders with further clarifications / queries on the Technical Bid. The bidder has to respond to the queries within the specified time mentioned in the covering letter.

2.4.6 On the date & time specified for opening of Financial Bid or the Revised Financial Bids as the case may be will be opened on specified date and time.

2.4.7 EVALUATION OF Financial Bids: The Financial Bid should contain the complete bid document with duly filled in Schedule of Financial Quote. Financial Bids opened as above will be checked for arithmetical errors.

2.4.8 The successful bidder shall be issued Letter of Acceptance (LOA) of the bid, and be required to furnish a Performance Guarantee as per General Conditions of Contract, Program Schedule with specific Milestones to be achieved as to complete the work within the stipulated time limit and details of his Technical Staff to be deployed as per ANNEXURE-I

2.4.9 Letter of Award (Work Order) shall be issued to the successful bidder only after receipt of the Performance Guarantee, along with Program Schedule and the details of Technical Staff to be deployed for the work.

2.4.10 Agreement (Contract) consisting of complete tender document including conditions, bill of quantities, technical proposal and specialized services, drawings, if any, and acceptance thereof together with any correspondence leading thereto, shall be drawn and signed with the awardee after issue of Work Order.

2.4.11 Date of start of work shall be reckoned from 7thday from the date of issue of “Letter of Acceptance”.

2.5 BIDDING CAPACITY OF CONTRACTORS

1) The bidding capacity of the contractor should be equal to or more than the estimated cost of the work put to tender. The bidding capacity shall be worked out by the following formula: Bidding Capacity = {[AxNx2]-B} Where, A= Maximum turnover in construction works executed in any one year during the last five years taking into account the completed as well as works in progress. The value of completed works shall be brought to current costing level by enhancing at a simple rate of 7% per annum. N= Number of years prescribed for completion of work for which bids has been invited. B= Value of existing commitments and ongoing works to be completed during the period of completion of work for which bids have been invited.

Page | 9

3. UNDERTAKING BY THE BIDDER

U N D E R T A K I N G

I / We have read and examined the Tender document including terms & conditions, specifications, bill of quantities, drawings and designs, general rules & directions, General Conditions of Contract, Special Conditions of Contract and all relevant other documents, publications and rules referred to in the Conditions of Contract and all other contents in the tender documents for the work.

I / We, hereby tender for execution of the work specified for the Indian Institute of Technology Kharagpur within the time specified and in accordance in all respects with the specifications, designs, drawings and instructions in writing.

We agree to keep the tender open for 120 days from the last date of its submission and not to make any modifications in its terms and conditions. An undertaking as mentioned in Bid Security Declaration Form (Annexure-III) has been deposited. If I / we, fail to furnish the prescribed performance guarantee within prescribed period, I / we agree that the said Director, Indian Institute of Technology Kharagpur or his authorized officer shall without prejudice to any other right or remedy, be at liberty to enforceactions as mentioned in the Bid Security Declaration Form (Annexure-III). Further, if I / we fail to commence work as specified, I / we agree that the Director, Indian Institute of Technology Kharagpur shall without prejudice to any other right or remedy available in law, be at liberty to enforceactions as mentioned in the Bid Security Declaration Form (Annexure-III) and forfeit the performance guarantee absolutely, to execute all the works referred to in the tender documents upon the terms and conditions contained or referred to therein.

Further, I / We agree that in case of enforcement of actions as mentioned in the Bid Security Declaration Form (Annexure-III) and/or Performance Guarantee as aforesaid, I / We shall be debarred for participation in the re-tendering process of the work.

I / We hereby declare that I / We shall treat the tender documents, drawings and other records connected with the work as secret / confidential documents and shall not communicate information derived there-from to any person other than a person to whom I / We am / are authorized to communicate the same or use the information in any manner prejudicial to the safety of the State.

Seal & Signature of Contractor

Postal Address

Dated

Witness

Address

Occupation

Page | 10

ANNEXURE-I

TECHNICAL STAFF OF CONTRACTOR

DISCIPLINE NAME QUALIFICATION EXPERIENCE CONTACT NUMBER

Overall Project In-charge

Engineer - Structure and Civil Works

Engineer – Electrical & Mechanical Works

In-charge - Safety, Health & Environment

Seal & Signature of Contractor

Page | 11

ANNEXURE - II

UNDERTAKING FOR GCC COMPLIANCE

UNDERTAKING

We hereby undertake that we shall fulfill all the terms & conditions within the specified time frame, after the acceptance of our offer in case our offer is accepted; failing which IIT KHARAGPUR may go ahead to take necessary action such as reporting the non-compliance to appropriate Government authorities and barring us from future participation in IIT KHARAGPUR works.

Seal & Signature of Contractor

DATED:

Page | 12

ANNEXURE - III

Bid Security Declaration Form

Date:__________________________Tender No. ________________________________________

To (Insert complete name and address of the purchaser)

I/We,the undersigned, declare that:

I/We understand that, according to your conditions, bids must be supported by a Bid Security Declaration.

I/We, accept that I/we may be disqualified from bidding for any contract with you for a period of one year from the date of notification if I am/We are in a breach of any obligation under the bid conditions, because I/We

a) Have withdrawn/modified/amended, impairs or derogates from the tender, my/our Bid during the period of bid validity specified in the form of Bid; or

b) Having been notified of the acceptance of our Bid by the purchaser during the period of bid validity (i) fail or reuse to execute the contract, if required, or (ii) fail or refuse to furnish the Performance Security, in accordance with the Instruction to Bidders.

I/We understand this Bid Securing Declaration shall cease to be valid if I am/We are not the successful Bidder, upon the earlier of (i) the receipt of your notification of the name of the successful Bidder; or (ii)thirty days after the expiration of the validity of my/ our Bid.

Signed: (insert signature of person whose name and capacity are shown)

In the capacity of (insert legal capacity of person signing the bid Securing Declaration)

Name: (insert complete name of person signing he Bid Securing Declaration)

Duly authorized to sign the bid for an on behalf of (insert complete name of Bidder)

Dated on …………………………………………….day of ……………………………………….. (Insert date of signing)

Corporate seal (where applicable)

Page | 13

ANNEXURE-IV

Format for Net Worth Certificate

It is to certify that as per the audited balance sheet and profit & loss account during the financial year ………………., the net worth of … (individual/farm/company) having registered address at ….…………………………. as on 31.3.2020 is Rs………..…………………….after considering all liabilities. It is further certified that the net worth of the company has not eroded by more than 30% in the last three years ending on 31.3.2020.

Signature of Chartered Accountant

…………..

Name of Chartered Accountant

…………..

Membership No. of ICAI

Date& Seal

Page | 14

ANNEXURE – A

(For Works Contracts, including Turnkey contracts)

(On Company / firm's Letterhead)

Tender No:………………………………… Dated:………………………..……..

CERTIFICATE

I/we have read the clause regarding restrictions on procurement from a bidder of a country which shares a land border with India and on sub-contracting to contractors from such countries and hereby certify that this bidder is not from such a country and will not sub-contract any work to a contractor from such countries unless such contractor is registered with the Competent Authority.

OR (whichever is applicable)

I/we have read the clause regarding restrictions on procurement from a bidder of a country which shares a land border with India and on sub-contracting to contractors from such countries; I/we hereby certify that this bidder is from ____________(Name of Country) and has been registered with the Competent Authority and will not sub-contract any work to a contractor from such countries unless such contractor is registered with the Competent Authority. I/we also certify that this bidder fulfils all the requirements in this regard and is eligible to be considered.

(Copy/ evidence of valid registration by the Competent Authority is to be attached with the bid document)

Signature of the Authorized Person

Date: -----------------------------

Full Name: ----------------------------

Place: ----------------------------

Company Seal: --------------

Page | 15

ANNEXURE – B

DECLARATION OF LOCAL CONTENT

(To be given on Company Letter Head – For tender value upto Rs.10 Crores)

(To be given by Statutory Auditor/Cost Auditor/ Practising Cost Accountant/ Practising Chartered Accountant for tender value in excess of Rs.10 Crores)

Tender No:………………………………… Dated:………………………..……..

To

The Chairman

Departmental Purchase Committee

Department of …………………..

IIT Kharagpur

PIN: 721302

Subject: Declaration of Local Content-reg.

1. Country of origin of Goods being offered:…………………………………………………………

2. We hereby declare that items offered has ……………..% local content.

(Clarification for Local content calculation as per OM No: P-45021/102/2019-BE-II-Part (1) (E-50310), dated 4th March 2021 of Department of Promotion of Industry and Internal Trade, Ministry of Commerce and Industry, Govt. of India.)

3. The details of the location(s) at which local value addition is made are given in the below table;

Sl. No. Name of the item Location(s) of local value addition

1 2 3

”Local Content” means the amount of value added in India which shall, unless otherwise prescribed by the Nodal Ministry, be the total value of the item procured (excluding net domestic indirect taxes) minus the value of the imported content in the item (including all customs duties) as a proportion of the total value, in percent.

Important:

“False declaration will be in breach of Code of Integrity under Rule 175(1)(i)(h) of the General Financial Rules 2017 for which a bidder or its successors can be debarred for up to two years as per Rule 151(iii) of the General Financial Rules 2017 along with such other actions as may be permissible under law.”

Date:

Yours faithfully,

(Signature of the bidder, with Official Seal)

Page | 16

4. Checklist for Documents to be uploaded on https://eprocure.gov.in/eprocure/app

Sl. No. Documents Reference

1. Tender Documents

2. EMD 1.2.5

3. Document support of Bona-fide Business Entity

1.3.3

4. GST Registration Certificate 1.3.3

5. Permanent Account Number 1.3.3

6. Average annual turnover of the bidder as per ITCC or profit and loss

statement for last 5 year

1.3.5

7. Experience Certificate 1.3.2

8. Net worth Certificate 1.3.6

9. ANNEXURES-I_II_III

10. SOQ

Page I 17

SCHEDULE OF QUANTITIES

Civil & Structural

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

1

Clearing grass and removal of the rubbish up to a distance

of 50 m outside the periphery of the area cleared. sqm 5857.00 6.40 37484.80

2

Transplantation of trees with necessary tools, tackles,

manpower, machineries, chemical and other assessories all

complete.

150 to 300 mm dia. Each 25.00 10497.00 262425.00

301 to 600 mm dia. Each 12.00 15745.00 188940.00

601 to 900 mm dia. Each 15.00 20993.00 314895.00

3

Earth work in excavation by mechanical means (Hydraulic

excavator)/manual means over areas (exceeding 30 cm in

depth, 1.5 m in width as well as 10 sqm on plan) including

getting out and disposal of excavated earth lead upto 50 m

and lift upto 1.5 m, as directed by Engineer-in-charge.

All kinds of soil cum 24000.00 181.85 4364400.00

4

Extra rates for quantities of works, executed:

In or under water and/or liquid mud, including pumping out

water as required

a) From 1m to 2m below EGL cum 5332.00 36.37 193924.84

b) From 2m to 3m below EGL cum 4872.00 72.74 354389.28

c) From 3m to 4m below EGL cum 4234.00 109.11 461971.74

d) From 4m to 5m below EGL cum 3342.00 145.48 486194.16

e) From 5m to 6m below EGL cum 2220.00 181.85 403707.00

5

Extra for every additional lift of 1.5 m or part thereof in

excavation /banking excavated or stacked materials - All

kinds of soils

a) From 1.5 m to 3m below EGL cum 7805.00 90.40 705572.00

b) From 3 m to 4.5m below EGL cum 6372.00 180.80 1152057.60

c) From 4.5 m to 6 below EGL cum 3823.00 271.20 1036797.60

6

Filling available excavated earth (excluding rock) in

trenches, plinth, sides of foundations etc. in layers not

exceeding 20cm in depth, consolidating each deposited

layer by ramming and watering, lead up to 50 m and lift

upto 1.5 m.

cum 14389.51 219.65 3160655.87

7

Extra for every additional lift of 1.5 m or part thereof in

excavation /

banking excavated or stacked materials - All kinds of soilscum 1213.89 90.40 109735.66

Name of Work: Construction of Deep & Shallow Water Maneuvering and Seakeeping Basin Facility for OE &

NA:

CIVIL CONSTRUCTION AND MAINTENANCE SECTION

IIT KHARAGPUR

Page I 18

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

8

Providing and laying 200 mm thick compacted bed of dry

brick aggregate of 40 mm thick nominal size including

spreading, well ramming, consolidating and grouting with

jamuna sand, including finishing smooth etc. complete as

per direction of Engineer-in-charge.

cum 1906.95 530.10 1010874.20

9

Providing and laying in position cement concrete of

specified grade excluding the cost of centering and

shuttering - All work up to plinth level :

1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone

aggregate 20 mm nominal size)

cum 897.25 6259.10 5615977.48

10

Making plinth protection 50mm thick of cement concrete

1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone

aggregate 20 mm nominal size) over 75mm thick bed of dry

brick ballast 40 mm nominal size, well rammed and

consolidated and grouted with fine sand, including

necessary excavation, levelling & dressing & finishing the

top smooth.

sqm 287.00 614.05 176232.35

11

Providing and fixing up to floor five level precast cement

concrete string or lacing courses, copings, bed plates,

anchor blocks, plain window sills, shelves, louvers, steps,

stair cases, etc., including hoisting and setting in position

with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of

required Centering complete.

1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded

stone aggregate 20mm nominal size)

cum 12.67 8537.75 108173.29

12

Providing and laying anti termite treatment to bottom

surface ( in case of masonry foundation and basements)

and the sides (upto a height of 300 mm. from bottom) of the

excavation trenches with chemical emulsion by admixing

chloropyrofos emulsifiable concentrates (1% concentration)

with water by weight at the rate of 5 Litres per sq. m. area.

The work shall be carried out as per specification described

in 6.2.1. of code IS 6313 (part -II) 1981. (Mode of

measurment will be the plan area of foundation treated.)

sqm 4582.00 111.86 512542.52

13

Providing and laying in position machine batched and

machine mixed design mix M-30 grade cement concrete for

reinforced cement concrete work, using cement content as

per approved design mix, including

pumping of concrete to site of laying but excluding the cost

of centering, shuttering, finishing and reinforcement,

including admixtures in recommended proportions as per

IS: 9103 to accelerate, retard setting of concrete, improve

workability without impairing strength and durability as per

direction of Engineer-in-charge. All works upto plinth level

cum 4385.48 8067.05 35377886.43

14As above but M-25 grade in all works above plinth and up to

level Vcum 736.13 9400.85 6920247.71

Page I 19

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

15

Centering and shuttering including strutting, propping etc.

and removal of form for :

Foundations, footings, bases of columns, etc. for mass

concrete sqm 1101.18 284.85 313671.12

Walls (any thickness) including attached pilasters,

butteresses, plinth and string courses, etc.sqm 5349.33 609.30 3259346.77

Suspended floors, roofs, landings, balconies and access

platformsqm 2610.12 693.05 1808943.67

As above but above 3.5 m height sqm 1337.01 980.55 1311005.16

Lintels, beams, plinth beams, girders, bressumers and

cantilevers

Plinth beams sqm 684.56 552.05 377911.35

Tie beams at 2nd level sqm 238.78 2277.05 543714.00

Tie beams at crane level sqm 330.20 2277.05 751881.91

Tie beams at roof level sqm 396.00 3139.55 1243261.80

Columns, Pillars, Piers, Abutments, Posts and Struts sqm 3764.79 733.70 2762226.42

Stairs, (excluding landings) except spiral-staircases sqm 33.21 622.35 20668.24

Small lintels not exceeding 1.5 m clear span, moulding as in

cornices, window sills, string courses, bands, copings, bed

plates, anchor blocks and the like.sqm 336.02 284.85 95715.30

16

Steel reinforcement for R.C.C. work including straightening,

cutting, bending, placing in position and binding all

complete upto plinth level.

Thermo Mechanically Treated bars of grade Fe-500D or

more

Kg 434279.18 83.50 36262311.53

17 As above but above plinth Kg 75846.37 83.50 6333171.90

18

Brick work with common burnt clay F.P.S. (non modular)

bricks of class designation 7.5 in foundation and plinth in:

Cement mortar 1:6 (1 cement : 6 coarse sand) cum 357.95 6157.45 2204059.23

19

Brick work with clay flyash F.P.S. (non modular) brick of

class designation 7.5 in superstructure above plinth level up

to floor five level in:

Cement mortar 1:4 (1 cement : 4 coarse sand) cum 618.00 7971.70 4926518.36

Page I 20

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

20

Providing and fixing factory made uPVC door frame made

of uPVC extruded sections having an overall dimension as

below (tolerance±1mm), with wall thickness 2.0 mm (± 0.2

mm), corners of the door frame to be Jointed with

galvanized brackets and stainless steel screws, joints

mitred and Plastic welded. The hinge side vertical of the

frames reinforced by galvanized M.S. tube of size 19 X 19

mm and 1mm (± 0.1 mm) wall thickness and 3 nos.

stainless steel hinges fixed to the frame complete as per

manufacturer’s specification and direction of Engineerin-

charge(i).Extruded section profile size 48x40 mm

m 47.60 221.65 10550.54

21

Providing and fixing 30 mm thick factory made Polyvinyl

Chloride (PVC) door shutter made of styles and rails of a

uPVC hollow section of size 60x30 mm and wall thickness 2

mm (± 0.2 mm), with inbuilt decorative moulding edging on

one side. The styles and rails mitred and joint at the corners

by means of M.S. galvanised/ plastic brackets of size

75x220 mm having wall thickness 1.0 mm and stainless

steel screws. The styles of the shutter reinforced by

inserting galvanised M.S. tube of size 25x20 mm and 1 mm

(± 0.1 mm) wall thickness. The lock rail made up of 'H'

section, a uPVC hollow section of size 100x30 mm and 2

mm (± 0.2 mm) wall thickness fixed to the shutter styles by

means of plastic/ galvanised M.S. 'U' cleats. The shutter

frame filled with a uPVC multi-chambered single panel of

size not less than 620 mm, having over all thickness of 20

mm and 1 mm (± 0.1 mm) wall thickness . The panels filled

vertically and tie bar at two places by inserting horizontally 6

mm galvanised M.S. rod and fastened with nuts and

washers, complete as per manufacturer's specification and

direction of Engineer-in-charge.

sqm 17.60 1978.65 34824.24

Page I 21

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

22

Providing and fixing factory made uPVC white colour sliding

glazed window upto 1.50 m in height dimension comprising

of uPVC multi-chambered frame with in-built roller track and

sash extruded profiles duly reinforced with 1.60 ± 0.2 mm

thick galvanized mild steel section made from roll forming

process of required length (shape & size according to uPVC

profile), appropriate dimension of uPVC extruded glazing

beads and uPVC extruded interlocks, EPDM gasket, wool

pile, zinc alloy (white powder coated) touch locks with hook,

zinc alloy body with single nylon rollers (weight bearing

capacity to be 40 kg), G.I fasteners 100 x 8 mm size for

fixing frame to finished wall and necessary stainless steel

screws etc. Profile of frame & sash shall be mitred cut and

fusion welded at all corners, including drilling of holes for

fixing hardware's and drainage of water etc. After fixing

frame the gap between frame and adjacent finished wall

shall be filled with weather proof silicon sealent over backer

rod of required size and of approved quality, all complete

as per approved drawing & direction of Engineer-in-Charge.

(Single / double glass panes, wire mesh and silicon sealent

shall be paid separately)

Note: For uPVC frame and sash extruded profiles minus

5% tolerance in dimension i.e. in depth & width of profile

shall be acceptable. Variation in profile dimension in higher

side shall be accepted but no extra payment on this account

shall be made.

Three track three panels sliding window with fly proof SS

wire mesh (Two nos. glazed & one no. wire mesh panels)

made of (small series) frame 92 x 44 mm & sash 32 x 60

mm both having wall thickness of 1.9 ± 0.2 mm and single

glazing bead of appropriate dimension (Area of window

upto 1.80 sqm).

sqm 3.60 8954.20 32235.12

23

Structural steel work riveted, bolted or welded in built up

sections, trusses and framed work, including cutting,

hoisting, fixing in position and applying a priming coat of

approved steel primer all complete.

Kg 174963.28 101.75 17802513.74

Page I 22

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

24

Supplying and fixing rolling shutters of approved make,

made of required size M.S. laths, interlocked together

through their entire length and jointed together at the end

by end locks, mounted on specially designed pipe shaft with

brackets, side guides and arrangements for inside and

outside locking with push and pull operation complete,

including the cost of providing and fixing necessary 27.5 cm

long wire springs manufactured from high tensile steel wire

of adequate strength conforming to IS: 4454 - part 1 and

M.S. top cover of required thickness for rolling shutters.

80x1.25 mm M.S. laths with 1.25 mm thick top cover sqm 25.00 2944.10 73602.50

25 Providing and fixing ball bearing for rolling shutters. Each 2.00 419.85 839.70

26

Extra for providing mechanical device chain and crank

operation for operating rolling shutters.

Exceeding 16.80 sqm in area sqm 25.00 1106.55 27663.75

27

Providing and fixing factory made ISI marked steel glazed

doors, windows and ventilators, side /top /centre hung, with

beading and all members such as F7D, F4B, K11 B and

K12 B etc. complete of standard rolled steel sections, joints

mitred and flash butt welded and sash bars tenoned and

riveted, including providing and fixing of hinges, pivots,

including priming coat of approved steel primer, but

excluding the cost of other fittings, complete all as per

approved design, (sectional weight of only steel members

shall be measured for payment). Fixing with 15x3 mm lugs

10 cm long embedded in cement concrete block 15x10x10

cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded

stone aggregate 20 mm nominal size) Doors

Kg 528.00 166.50 87912.00

28

Steel work welded in built up sections/ framed work,

including cutting, hoisting, fixing in position and applying a

priming coat of approved steel primer using structural steel

etc. as required.

In stringers, treads, landings etc. of stair cases, including

use of chequered plate wherever required, all complete Kg 2397.80 93.65 224553.97

In gratings, frames, guard bar, ladder, railings, brackets,

gates and similar works Kg 966.00 131.00 126546.00

29

Providing and fixing hand rail of approved size by welding

etc. to steel ladder railing, balcony railing, staircase railing

and similar works, including applying priming coat of

approved steel primer.

M.S. Tube Kg 3267.75 145.65 475947.79

Page I 23

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

30

Providing and fixing carbon steel galvanised (minimum

coating 5 micron) dash fastener of 10 mm dia double

threaded 6.8 grade (yield strength

480 N/mm2), counter sunk head, comprising of 10 mm dia

polyamide PA 6 grade sleeve, including drilling of hole in

frame , concrete/ masonry, etc. as per direction of Engineer-

in-charge.

10x80 mm Each 653.55 109.00 71236.95

31

Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand :

4 graded stone aggregate) finished with a floating coat of

neat cement, including cement slurry, but excluding the cost

of nosing of steps etc. complete.

40 mm thick with 20 mm nominal size stone aggregate sqm 365.69 498.35 182241.61

32Extra for making chequers of approved pattern on cement

concrete floors, steps, landing, pavements etc. sqm 365.69 63.20 23111.61

33

Kota stone slab flooring over 20 mm (average) thick base

laid over and jointed with grey cement slurry mixed with

pigment to match the shade of the slab, including rubbing

and polishing complete with base of cement mortar 1 : 4 (1

cement : 4 coarse sand)

25 mm thick sqm 130.98 1531.85 200641.71

34

Kota stone slabs 20 mm thick in risers of steps, skirting,

dado and pillars laid on 12 mm (average) thick cement

mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey

cement slurry mixed with pigment to match the shade of the

slabs, including rubbing and polishing complete.

sqm 124.71 1810.05 225731.34

35

Providing and laying Ceramic glazed floor tiles of size

300x300 mm of 1st quality conforming to IS : 15622 of

approved make in colours such as White, Ivory, Grey,

Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1

Cement : 4 Coarse sand), Jointing with grey cement slurry

@ 3.3 kg/sqm including pointing the joints with white

cement and matching pigment etc., complete.

sqm 33.29 926.90 30856.50

36

Providing and fixing 1st quality ceramic glazed floor tiles

conforming to IS : 15622 (thickness to be specified by the

manufacturer ) of approved make in all colours, shades

except burgundy, bottle green, black of any size as

approved by Engineer-in-Charge in skirting, risers of steps

and dados over 12 mm thick bed of cement Mortar 1:3 (1

cement: 3 coarse sand) and jointing with grey cement slurry

@ 3.3kg per sqm including pointing in white cement mixed

with pigment of matching shade

complete.

sqm 138.89 927.90 128876.03

Page I 24

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

37

Providing and laying vitrified floor tiles in different sizes

(thickness to be specified by the manufacturer) with water

absorption less than 0.08% and conforming to IS: 15622, of

approved make, in all colours and shades, laid on 20mm

thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing

with grey cement slurry @ 3.3 kg/ sqm including grouting

the joints with white cement and matching pigments etc.,

complete.

Size of Tile 600x600 mm sqm 33.07 1500.55 49623.19

38

Providing and laying Vitrified tiles in different sizes

(thickness to be specified by manufacturer), with water

absorption less than 0.08 % and conforming to I.S. 15622,

of approved make, in all colours & shade, in skirting, riser of

steps, over 12 mm thick bed of cement mortar 1:3 (1

cement: 3 coarse sand), jointing with grey cement slurry @

3.3 kg/ sqm including grouting the joint with white cement &

matching pigments etc. complete.

Size of Tile 600x600 mm sqm 4.57 1545.85 7064.53

39

Providing and fixing precoated galvanised iron profile

sheets (size, shape and pitch of corrugation as approved by

Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated

thickness with zinc coating 120 grams per sqm as per IS:

277, in 240 mpa steel grade, 5-7 microns epoxy primer on

both side of the sheet and polyester top coat 15-18

microns. Sheet should have protective guard film of 25

microns minimum to avoid scratches during transportation

and should be supplied in single length upto 12 metre or as

desired by Engineer in-charge. The sheet shall be fixed

using self drilling /self tapping screws of size (5.5x 55 mm)

with EPDM seal, complete upto any pitch in horizontal/

vertical or curved surfaces, excluding the cost of purlins,

rafters and trusses and including cutting to size and shape

wherever required.

sqm 671.01 627.55 421092.33

40

Supply of TRACDEK Klippon profiled sheeting 406 mm

cover width, 41 mm crests @ 203 mm c/c manufactured

out of 0.55 mm TCT (total coated thickness) SDP coated

Galvalume (275 Mpa yield stress) steel. The sheet shall

have wide pans with stiffening ribs for effective water

shedding and special male/ female ends on side-laps for

purlin support and anti-capillary flute in side lap. The sheet

shall have a hot-dip metallic coating of zinc aluminium alloy

coating mass total of both sides, AZ-150 as per AS 1397 )

having 275 Mpa yield stress. The sheets shall be fixed to

girts with concealed clips and no fasteners to penetrate the

sheeting. The sheets shall be supplied in lengths maximum

upto 6-12 metres to suit site dimensions.

sqm 4071.00 1874.25 7630071.75

Page I 25

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

41 As in 29 above but on vertical surfaces sqm 2145.86 627.55 1346634.44

42

Providing and fixing precoated galvanised steel sheet

roofing accessories 0.50 mm (+0.05 %) total coated

thickness, Zinc coating 120 grams per sqm as per IS: 277,

in 240 mpa steel grade, 5-7 microns epoxy primer on both

side of the sheet and polyester top coat 15-18 microns

using self drilling/ self tapping screws complete :

Ridges plain (500-600 mm) m 120.00 416.30 49956.00

Flashings/aprons. (upto 600 mm) m 1005.00 368.60 370443.00

Gutters (600 mm overall girth) m 140.00 1041.75 145845.00

43

Providing and fixing tiled false ceiling of specified materials

of size 595x595 mm in true horizontal level, suspended on

inter locking metal grid of hot dipped galvanized steel

sections ( galvanized @ 120 grams/ sqm, both side

inclusive) consisting of main "T" runner with suitably spaced

joints to get required length and of size 24x38 mm made

from 0.30 mm thick (minimum) sheet, spaced at 1200 mm

center to center and cross "T" of size 24x25 mm made of

0.30 mm thick (minimum) sheet, 1200 mm long spaced

between main "T" at 600 mm center to center to form a grid

of 1200x600 mm and secondary cross "T" of length 600

mm and size 24x25 mm made of 0.30 mm thick (minimum)

sheet to be interlocked at middle of the 1200x600 mm panel

to form grids of 600x600 mm and wall angle of size

24x24x0.3 mm and laying false ceiling tiles of approved

texture in the grid including, required cutting/making,

opening for services like diffusers, grills, light fittings,

fixtures, smoke detectors etc. Main "T" runners to be

suspended from ceiling using GI slotted cleats of size 27 x

37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50

mm long dash fasteners, 4 mm GI adjustable rods with

galvanised butterfly level clips of size 85 x 30 x 0.8 mm

spaced at 1200 mm center to center along main T, bottom

exposed width of 24 mm of all T-sections shall be pre-

painted with polyester paint, all complete for all heights as

per specifications, drawings and as directed by Engineer-in-

charge.

12.5 mm thick fully Perforated Gypsum Board tile made

from plasterboard having glass fibre conforming to IS: 2095

part I, of size 595x595 mm, having perforation of 9.7x9.7

mm at 19.4 mm c/c with center borders of 48 mm and the

side borders of 30 mm, backed with non woven tissue on

the back side, having an NRC (Noise Reduction Coefficient)

of 0.79, with 50 mm resin bonded glass wool backing.

sqm 255.14 1171.50 298896.51

Page I 26

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

44

Providing and applying 12 mm thick internal cement plaster

in mix 1:4 (1 cement : 4 fine sand) including curing,

scaffolding, etc. complete, ready to receive wall finish.sqm 11040.31 266.85 2946106.72

45

Providing and applying 18 mm thick external plaster at all

heights, in two coats under layer 12 mm thick cement

plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm

thick cement plaster 1:3 (1 cement : 3 coarse sand) finished

rough with sponge including curing, scaffolding, etc.

complete.

sqm 3214.52 416.55 1339008.31

46

Providing and applying 6 mm cement plaster of mix 1:3 (1

cement : 3 fine sand) in ceilings including curing,

scaffolding, etc. complete.

sqm 623.53 227.35 141759.55

47

Distempering with oil bound washable distemper of

approved brand and manufacture to give an even shade:

New work (two or more coats) over and including water

thinnable priming coat with cement primer.

sqm 11663.84 153.45 1789816.25

48

Applying and finishing walls with 100% Premium acrylic

emulsion paint having VOC less than 50 gm/litre and UV

resistance as per IS 15489:2004, Alkali & fungal resistance,

dirt resistance exterior paint of required shade (Company

Depot Tinted) with silicon additives.

New work (Two or more coats applied @ 1.43 litre/10 sqm.

Over and including priming coat of exterior primer applied

@ 0.90 litre/10 sqm.

sqm 3214.52 146.20 469962.82

49

Painting with synthetic enamel paint, having VOC (Volatile

OrganicCompound) content less than 150 grams/ litre, of

approved brand and manufacture, including applying

additional coats wherever required to achieve even shade

and colour. Two coats

sqm 6803.08 75.00 510231.00

50

Providing and laying 175 mm thick C.C. pavement of mix M-

25 with ready mixed concrete from batching plant. The

ready mixed concrete shall be laid and finished with screed

board vibrator, vacuum dewatering process and finally

finished by floating, brooming with wire brush etc. complete

as per specifications and directions of Engineer-in charge.

(The panel shuttering work shall be paid for separately).

(Note:- Cement content considered in this item is @ 330

kg/cum. Excess/less cement used as per design mix is

payable/ recoverable separately).

cum 386.58 8663.05 3348961.87

Page I 27

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

51

Supplying, fitting & fixing UPVC pipes A- Type and fittings

conforming to IS:13592-1992 with all necessary clamps

nails, including making holes in walls, floor etc. cutting

trenches in any soil through masonry concrete structures

etc if necessary and mending good damages including

joining with jointing materails (Spun Yarn,

Valamoid/Bitumen/M-Seal etc) complete.

UPVC pipes 160 mm dia. m 323.60 577.15 186765.74

UPVC Fiitings Plain T 160 mm dia Each 3.00 603.33 1809.99

UPVC Fittings Bends 87.5 degree Each 39.00 480.76 18749.64

52

Boring, providing and installation bored cast-in-situ

reinforced cement concrete piles of grade M-25 of specified

diameter and length below the pile cap, to carry a safe

working load not less than specified, excluding the cost of

steel reinforcement but including the cost of boring with

bentonite solution and temporary casing of appropriate

length for setting out and removal of same and the length of

the pile to be embedded in the pile cap etc. by percussion

drilling using Direct mud circulation (DMC) or Bailer and

chisel technique by tripod and mechanical Winch Machine

all complete, including removal of excavated earth with all

its lifts and leads (length of pile for payment shall be

measured up to bottom of pile cap). Note: Truck Mounted

rotary/TMR/Tubewell boring machine shall not be used.

- 750 mm dia piles

m 360.00 4482.30 1613628.00

53

Providing and laying integral cement based water proofing

treatment including preparation of surface as required for

treatment of roofs, balconies, terraces etc consisting of

following operations:

(a) Applying a slurry coat of neat cement using 2.75 kg/sqm

of cement admixed with water proofing compound

conforming to IS. 2645 and approved by Engineer-in-

charge over the RCC slab including adjoining walls upto

300 mm height including cleaning the surface before

treatment.

(b) Laying brick bats with mortar using broken bricks/brick

bats 25 mm to 115 mm size with 50% of cement mortar 1:5

(1 cement : 5 coarse sand) admixed with water proofing

compound conforming to IS : 2645 and approved by

Engineer-in-charge over 20 mm thick layer of cement

mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with

water proofing compound conforming to IS : 2645 and

approved by Engineer-in-charge to required slope and

treating similarly the adjoining walls upto 300 mm height

including rounding of junctions of walls and slabs.

Page I 28

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

(c) After two days of proper curing applying a second coat

of cement slurry using 2.75 kg/ sqm of cement admixed

with water proofing compound conforming to IS : 2645 and

approved by Engineer-in-charge.

(d) Finishing the surface with 20 mm thick jointless cement

mortar of mix 1:4 (1 cement :4 coarse sand) admixed with

water proofing compound conforming to IS : 2645 and

approved by Engineerin-charge including laying glass fibre

cloth of approved quality in top layer of plaster and finally

finishing the surface with trowel with neat cement slurry and

making pattern of 300x300 mm square 3 mm deep.

(e) The whole surface so finished shall be flooded with

water for a minimum period of two weeks for curing and for

final test.“All above operations to be done in order and as

directed and specified by the Engineer-in-Charge :

With average thickness of 120 mm and minimum thickness

at khurra as 65 mm over raft of storage tank. sqm 368.12 1398.50 514815.82

54

Providing and applying integral crystalline slurry of

hydrophilic in nature for waterproofing treatment to the RCC

structures like retaining walls of the basement, water tanks,

roof slabs, podiums, reservior, sewage & water treatment

plant, tunnels / subway and bridge deck etc., prepared by

mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry :

2 parts water) for vertical surfaces and 3 : 1 (3 parts integral

crystalline slurry : 1 part water) for horizontal surfaces and

applying the same from negative (internal) side with the

help of synthetic fiber brush. The material shall meet the

requirements as specified in ACI 212-3R-2010 i.e by

reducing permeability of concrete by more than 90%

compared with control concrete as per DIN 1048 and

resistant to 16 bar hydrostatic pressure on negative side.

The crystalline slurry shall be capable of self-healing of

cracks up to a width of 0.50mm. The work shall be carried

out all complete as per specification and the direction of the

engineer-in-charge. The product performance shall carry

guarantee for 10 years against any leakage.

For vertical surface two coats @ 0.70 kg per sqm sqm 2118.37 484.45 1026244.35

For horizontal surface one coat @1.10 kg per sqm. sqm 1962.84 373.40 732924.46

55

Supply, transport, loading / unloading, erection, testing and

commissioning of EOT crane - 3T capacity including rails Each 1.00 3591420.00 3591420.00

Page I 29

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

56

Planting of trees ( Avenue plants) in 0.60m dia holea, 1m

deep dug in the ground, mixing the soil with decayed farm

yard/sludge manure. This includes supply of labour, tools &

plants including materials but excluding cost of tree.Each 40.00 139.23 5569.20

57

Maintanance of trees for one year (Avenue Plants) including

watering, trimming, manuring, spraying insecticide and

guarding as required. This includes supply of labour, tools &

plants including materials.

Each 40.00 567.63 22705.20

58

Providing and fixing aluminium work for doors, windows,

ventilators and partitions with extruded built up standard

tubular sections/ appropriate Z sections and other sections

of approved make conforming to IS: 733 and IS: 1285,

fixing with dash fasteners of required dia and size, including

necessary filling up the gaps at junctions, i.e. at top, bottom

and sides with required EPDM rubber/ neoprene gasket etc.

Aluminium sections shall be smooth, rust free, straight,

mitred and jointed mechanically wherever required including

cleat angle, Aluminium snap beading for glazing / paneling,

C.P. brass / stainless steel screws, all complete as per

architectural drawings and the directions of Engineer-in-

charge. (Glazing, paneling and dash fasteners to be paid

for separately) :Powder coated aluminium (minimum

thicknessof powder coating 50 micron)

Kg 420.33 456.30 191796.58

59

For shutters of doors, windows & ventilators including

providing and fixing hinges/ pivots and making provision for

fixing of fittings wherever required including the cost of

EPDM rubber / neoprene gasket required (Fittings shall be

paid for separately) Powder coated aluminium (minimum

thickness of powder coating 50 micron).

Kg 226.22 546.35 123595.30

60

Providing and fixing 12 mm thick prelaminated particle

board flatpressed three layer or graded wood particle board

conforming to IS: 12823 Grade l Type ll, in panelling fixed in

aluminum doors, windows shutters and partition frames with

C.P. brass / stainless steel screws etc. complete as per

architectural drawings and directions of Engineer-in-charge.

Pre-laminated particle board with decorative lamination on

both sides.

sqm 50.16 1046.90 52512.50

61

Providing and fixing glazing in aluminium door, window,

ventilatorshutters and partitions etc. with EPDM rubber /

neoprene gasket etc. complete as per the architectural

drawings and the directions of Engineer-in-charge With

float glass panes of 5.50 mm thickness plain / frosted.

sqm 3.60 1296.40 4667.04

Page I 30

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

62

Filling the gap in between aluminium frame & adjacent

RCC/ Brick/Stone work by providing weather silicon sealant

over backer rod of approved quality as per architectural

drawings and direction of Engineer-in-charge complete. Up

to 5 mm depth & 5 mm width

m 97.60 79.45 7754.32

63

Providing and fixing double glazed hermetically sealed

glazing in aluminium windows, ventilators and partition etc.

with 6 mm thick clear float glass both side, having 12 mm

air gap, including providing EPDM gasket, perforated

aluminium spacers, desiccants, sealant (Both primary and

secondary sealant) etc. as per specifications, drawings and

direction of Engineer-in-charge complete.

sqm 50.52 6399.35 323295.16

64

Providing and fixing 12 mm thick frameless toughened

glass door shutter of approved brand and manufacture,

including providing and fixing top & bottom pivot & double

action hydraulic floor spring type fixing arrangement and

making necessary holes etc. for fixing required door fittings,

all complete as per direction of Engineer-incharge (Door

handle, lock and stopper etc.to be paid separately).

sqm 5.50 4447.90 24463.45

65Providing and fixing bright finished brass hanging type floor

door stopper Each 19.00 106.70 2027.30

66

Providing and fixing aluminium die cast body tubular type

universal hydraulic door closer (having brand logo with ISI,

IS : 3564, embossed on the body, door weight upto 35 kg

and door width upto 700 mm), with necessary accessories

and screws etc. complete.

Each 23.00 1003.50 23080.50

67

Providing and fixing chromium plated brass 100 mm mortice

latch and lock with 6 levers and a pair of lever handles of

approved quality with necessary screws etc. complete. Each 17.00 806.45 13709.65

68

Providing and fixing panic bar / latch (Double point) fitted

with a single body, Trim Latch & Lock on back side of the

Panic Latch of reputed brand and manufacture to be

approved by the Engineer- in- charge, all complete.

Each 2.00 7134.85 14269.70

69

Providing and fixing bright /matt finished Stainless Steel

handles of approved quality & make with necessary screws

etc all complete. -125 mmEach 21.00 98.75 2073.75

70Providing and fixing in position 3.5 m high, 8 inch wide and

2-3 mm thick PVC curtain strips m 12.00 2979.76 35757.12

71

Providing and Placing in position suitable PVC water stops

conforming to IS:12200 for construction/ expansion joints

between two RCC members and fixed to the reinforcement

with binding wire before pouring concrete etc. complete :

Serrated with central bulb (225 mm wide, 8-11 mm thick)

m 977.42 283.20 276805.34

TOTAL 174605289.74

Say Rs. 174605290.00

Page l 31

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

1

Providing and fixing white vitreous china pedestal type water

closet (European type W.C. pan) with seat and lid, 10 litre low

level white P.V.C. flushing cistern, including flush pipe, with

manually controlled device (handle lever), conforming to IS :

7231, with all fittings and fixtures complete, including cutting and

making good the walls and floors wherever required :W.C.pan

with ISI marked white solid plastic seat and lid

Each 5 5260.95 26304.75

2

Providing and fixing white vitreous china flat back half stall urinal

of size 580x380x350 mm with white PVC automatic flushing

cistern, with fittings, standard size C.P. brass flush pipe,

spreaders with unions and clamps (all in C.P. brass) with waste

fitting as per IS :2556, C.I. trap with outlet grating and other

couplings in C.P. brass, including painting of fittings and cutting

and making good the walls and floors wherever required : Single

half stall urinal with 5 litre P.V.C. automatic flushing cistern

Each 3 9360.6 28081.80

3

Providing and fixing wash basin with C.I. brackets, 15 mm C.P.

brass pillar taps, 32 mm C.P. brass waste of standard pattern,

including painting of fittings and brackets, cutting and making

good the walls wherever require:

White Vitreous China Wash basin size 630x450 mm with a single

15 mm C.P. brass pillar tap

Each 5 3087.7 15438.50

4

Providing and fixing stone slab with table rubbed, edges rounded

and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in

urinal partitions by cutting a chase of appropriate width with

chase cutter and embedding the stone in the chase with epoxy

grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand :

4 graded stone aggregate 6 mm nominal size) as per direction of

Engineer-in-charge and finished smooth. Granite stone of

approved shade

Each 3 3216.9 9650.70

5Supplying, fitting and fixing two way Bib Cock with wall flange

(CAT. No. CQT23041 of JAQUAR make or equivalent).Each 5 1185 5925.00

6

Supplying, fitting and fixing Chromium plated Hand

shower(Health Faucet) with Flexible Tube with long1 mtr&wall

hook (CAT. No. ALD563 of Jaquar make or equivalent).Each 5 1301 6505.00

7

Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)

pipes, having thermal stability for hot & cold water supply

including all CPVC plain & brass threaded fittings This includes

jointing of pipes & fittings with one step CPVC solvent cement,

trenching, refilling & testing of joints complete as per direction of

Engineer in Charge.

m

50 mm nominal outer dia pipes 10.00 791.65 7916.50

40 mm nominal outer dia pipes 82.00 536.75 44013.50

Plumbing

Page l 32

32 mm nominal outer dia pipes 43.00 413.7 17789.10

25 mm nominal outer dia pipes 12.00 326.65 3919.80

20 mm nominal outer dia pipes 8.00 253.7 2029.60

15 mm nominal outer dia pipes 5.00 202.85 1014.25

8

Providing and fixing trap of self cleansing design with screwed

down or hinged grating with or without vent arm complete,

including cost of cutting and making good the walls and floors :

100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS:

3989

Each 6 1512.55 9075.30

9 As above but 100 mm inlet and 75 mm outlet Each 4 1579.45 6317.80

10Providing and fixing toilet paper holder :

CP BrassEach 5 583.75 2918.75

11

Providing and fixing PTMT liquid soap container 109 mm wide,

125 mm high and 112 mm distance from wall of standard shape

with bracket of the same materials with snap fittings of approved

quality and colour, weighing not less than 105 gms.

Each 5 158.55 792.75

12

Providing and fixing C.P. brass long body bib cock of approved

quality conforming to IS standards and weighing not less than

690 gms.

15 mm nominal bore

Each 8 552.35 4418.80

13

Providing and fixing C.P. brass stop cock (concealed) of

standard design and of approved make conforming to IS:8931.

15 mm nominal bore

Each 9 606.25 5456.25

14

Providing and fixing 600x450 mm beveled edge mirror of

superior glass (of approved quality) complete with 6 mm thick

hard board ground fixed to wooden cleats with C.P. Brass screws

and washers complete.

Each 3 1283.05 3849.15

15

Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink

as per IS:13983 with C.I. brackets and stainless steel plug 40

mm, including painting of fittings and brackets, cutting and

making good the walls wherever required :

Kitchen sink with drain board 510x1040 mm bowl depth 225 mm

Each 1 5851.7 5851.70

16

Providing and fixing square-mouth S.W. gully trap class SP-1

complete with C.I. grating brick masonry chamber with water

tight C.I. cover with frame of 300 x300 mm size (inside) the

weight of cover to be not less than 4.50 kg and frame to be not

less than 2.70 kg as per standard design:

100x100 mm size P type With common burnt clay F.P.S. (non

modular) bricks of class designation 7.5

Each 2 2307 4614.00

Page l 33

17

Supplying, fitting & fixing UPVC pipes A- Type and fittings

conforming to IS:13592-1992 with all necessary clamps nails,

including making holes in walls, floor etc. cutting trenches in any

soil through masonry concrete structures etc if necessary and

mending good damages including joining with jointing materails

(Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.

m

75 mm dia 27.00 223.72 6040.44

110 mm dia 26.00 298.69 7765.94

160 mm dia 70.00 577.15 40400.50

18

Constructing brick masonry manhole in cement mortar 1:4 ( 1

cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1

cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate

20 mm nominal size), foundation concrete 1:4:8 mix (1 cement :

4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm

nominal size), inside plastering 12 mm thick with cement mortar

1:3 (1 cement : 3 coarse sand) finished with floating coat of neat

cement and making channels in cement concrete 1:2:4 (1

cement : 2 coarse sand : 4 graded stone aggregate 20 mm

nominal size) finished with a floating coat of neat cement

complete as per standard design :Inside size 120x90 cm and 90

cm deep including C.I. cover with frame (medium duty) 500 mm

internal diameter, total weight of cover and frame to be not less

than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :

With common burnt clay F.P.S. (non modular) bricks of class

designation 7.5

Each 7 10905.05 76335.35

19

Providing and placing on terrace (at all floor levels) polyethylene

water storage tank, IS : 12701 marked, with cover and suitable

locking arrangement and making necessary holes for inlet, outlet

and overflow pipes but without fittings and the base support for

tank.

Litre 1000 8.8 8800.00

20

Providing and fixing ball valve (brass) of approved quality, High

or low pressure, with plastic floats complete:

25 mm nominal bore Each 2 394 788.00

21Providing and fixing gun metal gate valve with C.I. wheel of

approved 32 mm nominal boreEach 4 581.25 2325.00

22 as above but 40 mm nominal bore Each 4 678.4 2713.60

23Providing and fixing PTMT Bottle Trap for Wash basin and sink.

Each 7 335.25 2346.75

24

Providing and fixing PTMT Waste Coupling for wash basin and

sink, of approved quality and colour.

Waste coupling 31 mm dia of 79 mm length and 62mm breadth

weighing not less than 45 gms

Each 7 99.75 698.25

Total for Plumbing TOTAL 360096.83

360097.00

Page l 34

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

1

Providing and installing roof mounted wind driven natural

turbo ventilators including making suitable cut outs in roofing

sheets, sealing the openings to provide weathertight and

watertight roof. Etc. complete.

1200 CFM capacity, approx. 600 mm diameter

Each 7 7116.20 49813.40

2

Providing , installing, testing and commissioning of Inverter

AC (Make: Daikin/ Hitachi/ Voltas/ Blue Star) Hi Wall units

with suitable refrigerant complete with power cable from the

unit to the power socket.

2.0 TR x 5 STAR - FS324YBTU Each 4 47610.00 190440.00

1.5 TR x 5 STAR - FS318DLTU Each 2 38720.00 77440.00

3Providing and installing wall mounted powder coated stand for

outdoor unitEach 6 649.00 3894.00

4Providing, installing, testing and commissioning of 5 KVA V-

Guard voltage stabilizerEach 6 2205.00 13230.00

5Providing and laying / fixing copper piping for the above Hi

Wall unitsm 70 737.50 51625.00

6 Providing and fixing microcellular pipe insulation Class O m

6.35 ID x 10 mm thick 70 29.50 2065.00

12.5 ID x 10 mm thick 70 33.00 2310.00

25 mm ID x 9 mm thick 70 41.30 2891.00

7

Providing and laying flexible copper cable (3C x 2.5 sq. mm.)

including clamping / fixing to RCC and wall supports. Make:

Polycab

m 70 123.90 8673.00

8

Providing and fixing 25 mm UPVC drain pipe to the required

line and slope including clamping / fixing to RC and wall

supports. Make: Astral

m 70 70.80 4956.00

Total 407337.40

Say Rs. 407337.00

HVAC

Price l 35

RATE AMOUNT RATE AMOUNT

ELECTRICAL

IMPORTANT NOTES :

A

Quantity UR means Unit Rate to be quoted. The quantity shall be as per site requirement

& as directed by client's site engineer.

B

The quantities mentioned in this document are estimated on the basis of drawings

prepared & submitted to client. The contractor has to physically measure, prepare BOQ &

get written approval before procurement of material from client's site engineer.

CThe contractor shall prepare measurement sheet for the work done & get it certified from

clients site engineer. The billing will be done as per certified measurement sheet & P.O.

D No rates (Supply & Installation) change for the quantity variation up to 25%

EMeasurement of LT Busduct shall be done by contractor at site as per actual location &

then the item should be procured.

1 11kV VCB PANEL

1.1

Supply, erection, testing and commissioning of Two panel vaccum switchgear unit (VCB)

with following features:

a) The panel unit should have 11kV,3pole,50Hz,400Amps,250MVA,13.1kA symmentrical

breaking capacity, single phase motor operated & manual spring charging system with

power pack and intelligent quasar metering with RS485 communication facilities as per

IS:2516

b) Power pack 110 Volts DC unit for control circuit supply for each panel.

c) The PT Should be resin cast bus connected in separate bus PT enclosure, resin cast,

dry type having voltage ration 11kV/110V,3phase,3wire,50Hz horizontal draw out type as

per IS 3156. Burden of 100VA and accuracy class as 1.0

d)CT ratio : 100/5+5, Protection class 5P10 and metering accuracy class 1.0

e) Breaker should have E/F, O/C, S/C Protection with microprocessor based E/F, S/C,

O/C IDMTL Relay, along with Master trip for each panel.

f) ON, OFF, Spring charge, Trip circuit healthy, Indication must be in the panel.

g) WTI, OTI,Bunchhole alarm and trip with annunciation facility for each panel.

h) The above VCB should be eredted on masonary trench in angle iron frame including

supply and fixing of angle iron frame.

i) Provision of a earthing trolley.

j) The GA and SLD are to be submitted for verification and approval from institute.

Make: ABB,Schnider,Siemens

No. 1.00 8,00,000 800000.00 0.00 800000.00

2 TRANSFORMER :

2.1

Installation Testing commissioning of 11kV/415V, 500KVA transformer in substation no –

14 which includes filtration of transformer oil of 2500L.

The details of job include: -

i) Testing of BDV

ii) Megger value, voltage ratio at all tap position

iii) Core Balance

iv) Vector group

v) O/C & S/C test and determination of internal impedance

vi) DGA Test report.

No. 1.00 41,000 41000.00 0.00 41000.00

Following precommissioning tests are included in scope of contractor.

Testing of BDV

Megger value, voltage ratio at all tap position

Core Balance

Vector group

O/C & S/C test and determination of internal impedance

DGA Test report.

3 LOW VOLTAGE SWITCH BOARDS :

Supply, Unloading, Installation Testing and Commissioning of following floor mounted TTA

panels as per SLD enclosed. The rate shall include unloading of Panels from transport

vehicle, shifting to the stores or near by site location & then to the location of panels,

including crane hiring charges, lifting shifting tools tackles, manpower, mounting on

supports etc. as directed by site engineer. Work also involves positioning panel on

prepared trench and support channels panel alignment, assembling transport section of

panels, fixing of panels to based channels with fasteners or on floor / wall with anchor

fasteners as per requirements, bus bar & earth bus interconnections, tightening of joints,

bolts, hardware etc. and wiring of loosely supplied components and accessories as

manufacturers instructions, operational checks but excluding supply of structural steel.

(Supply, fabrication & painting of Structural steel has been included separately elsewhere

in the tender). (rate shall include use of hydra, loading, unloading facility for each pannel)

(Make: Siemense/ABB/L&T/Schneider/Legrand)

3.1 MAIN LT PANEL No. 1.00 4,08,480 408480.00 23940.00 23940.00 432420.00

Panel shall be Indoor type with IP42 Protection.

Electrical:

INSTALLATIONAMOUNTQTYSR. NO. DESCRIPTION UNIT

SUPPLY

Price l 36

RATE AMOUNT RATE AMOUNT

INSTALLATIONAMOUNTQTYSR. NO. DESCRIPTION UNIT

SUPPLY

FORM 3B

14 SWG CRCA

ALUMINIUM BUS

CURRENT DENSITY :- 0.8 AMP/1 SQ. MM.

IP PROTECTION - IP 42 (SUITABLE FOR INDOOR CONDITION)

ALL CABLES- TOP CABLE ENTRIES

AS PER CALCULATION FAULT CURRENT :- 50 KA

All panels Switchgear will be provided with lockout tagout (LOTO)arrangement.

INDICATIONS POSITION

FOR ALL INCOMERS PHASE INDICATION WITH SWITCH POSITION.

FOR ALL OUTGOINGS FOR SWITCH ON INDICATION

PROTECTIONS: SURGE PROTECTION ON INCOMER

SINGLE PHASING PREVENTER ON INCOMING BUS FOR PHASE IN BALANCE AND

SINGLE PHASE PREVENTIONS

METERING

MULTIFUNCTION METER FOR INCOMING SUPPLY BREAKERS

EB INCOMER

800 A FP ACB FOR TRANSFORMER INCOMER

EDO TYPE MICROPROCESSOR BASED WITH LSIGN PROTECTION.

RACKING HANDLE, RACKING INTERLOCK, SAFTY SHUTTER, DOOR SEALING

FRAME,READY TO CLOSED SHUNT TRIP COIL (230V), UNDER VOLTAGE COIL

(415V), TRIP SIGNAL SWITCH, AUX. CONTACTS ( AS REQUIRED).

PROVIDE RYB + ON&OFF&TRIP INDICATION LAMPS AND MFM METER TO THIS

FFEDER

OUTGOINGS

500 A FP MCCB - 1 NOS

4 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON&OFF&TRIP INDICATION LAMPS

400 A FP MCCB - 1 NOS

4 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

100 A FP MCCB - 3 NOS

3 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

80 A FP MCCB - 3 NOS

3 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

63 A FP MCCB - 4 NOS

3 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

40 A FP MCCB - 5 NOS

3 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

32 A FP MCCB - 1 NOS

3 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

3.2 240 KVAR AUTOMATIC POWER FACTOR CORRECTION No. 1.00 10,21,200 1021200.00 10640.00 10640.00 1031840.00

240 KVAR Effective @ 415 VOLTS,THYRISTERISED APFC PANEL

Panel shall be Indoor type.

FORM 2B

14 SWG CRCA

ALUMINIUM BUS

CURRENT DENSITY :- 0.8 AMP/ 1 SQ. MM.

ALL CABLES- TOP CABLES ENTRIES

DIGITAL VOLTMETER & AMMETER FOR INCOMING SUPPLY BREAKERS

KA RATING :- 50 KA

INDICATIONS POSITION

FOR ALL CAPACITOR STEPS ON OFF INDICATION SHOULD BE PROVIDED

The Switching of Capacitors should be done with the Thyristors.

"APP" Type Capacitors should be used. With suitable voltage (525 volts)

7 % Detuned Reactors should added in a circuit to neutralise the Harmonics

generated in a circuit

Power Factor Controller should have the provision to Monitor the kVARh lagging

and leading values and operate capacitors accordingly. This needs as per new

MSEDCL Circular.

Adequoate Ventilation should be arranged while designing the General Arrangement of

Panel. Proper Lowers and Exhaust fans of required CFM should be used.

INCOMER

500A TP MCCB FOR REAL TIME POWER FACTOR CORRECTION PANEL

3 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

OUTGOINGS

100 A FP MCCB - 3 NOS (for 50kVAr capacitor bank with thyristerised switching)

Price l 37

RATE AMOUNT RATE AMOUNT

INSTALLATIONAMOUNTQTYSR. NO. DESCRIPTION UNIT

SUPPLY

4 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

63 A FP MCCB - 2 NOS (for 25kVAr capacitor bank with thyristerised switching)

4 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

40 A FP MCCB - 1 NOS (for 20kVAr capacitor bank with thyristerised switching)

3 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

25 A FP MCCB - 1 NOS (for 10kVAr capacitor bank with thyristerised switching)

3 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

16 A FP MCCB - 2 NOS (for 5kVAr capacitor bank with thyristerised switching)

3 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

3.3 FIRE FIGHTING PANEL No. 1.00 1,92,717 192717.00 13300.00 13300.00 206017.00

Panel shall be Indoor type with IP42 Protection.

FORM 3B

14 SWG CRCA

ALUMINIUM BUS

CURRENT DENSITY :- 0.8 AMP/1 SQ. MM.

IP PROTECTION - IP 42 (SUITABLE FOR INDOOR CONDITION)

ALL CABLES- TOP CABLE ENTRIES

AS PER CALCULATION FAULT CURRENT :- 50 KA

All panels Switchgear will be provided with lockout tagout (LOTO)arrangement.

INDICATIONS POSITION

FOR ALL INCOMERS PHASE INDICATION WITH SWITCH POSITION.

FOR ALL OUTGOINGS FOR SWITCH ON INDICATION

PROTECTIONS: SURGE PROTECTION ON INCOMER

SINGLE PHASING PREVENTER ON INCOMING BUS FOR PHASE IN BALANCE AND

SINGLE PHASE PREVENTIONS

METERING

MULTIFUNCTION METER FOR INCOMING SUPPLY BREAKERS

EB INCOMER

80 A FP MCCB - 1 NOS

3 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

OUTGOINGS

63 A FP MCCB - 2 NOS

4 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

40 A FP MCCB - 1 NOS

4 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

16 A FP MCCB - 1 NOS

4 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

3.4 WATER MANAGEMENT PANEL No. 1.00 2,82,900 282900.00 13300.00 13300.00 296200.00

Panel shall be Indoor type with IP42 Protection.

FORM 3B

14 SWG CRCA

ALUMINIUM BUS

CURRENT DENSITY :- 0.8 AMP/1 SQ. MM.

IP PROTECTION - IP 42 (SUITABLE FOR INDOOR CONDITION)

ALL CABLES- TOP CABLE ENTRIES

AS PER CALCULATION FAULT CURRENT :- 50 KA

All panels Switchgear will be provided with lockout tagout (LOTO)arrangement.

INDICATIONS POSITION

FOR ALL INCOMERS PHASE INDICATION WITH SWITCH POSITION.

FOR ALL OUTGOINGS FOR SWITCH ON INDICATION

PROTECTIONS: SURGE PROTECTION ON INCOMER

SINGLE PHASING PREVENTER ON INCOMING BUS FOR PHASE IN BALANCE AND

SINGLE PHASE PREVENTIONS

METERING

MULTIFUNCTION METER FOR INCOMING SUPPLY BREAKERS

EB INCOMER

80 A FP MCCB - 1 NOS

3 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

OUTGOINGS

40 A FP MCCB - 5 NOS

4 POLE MCCB LSI PROTECTION WITH THERMAL MAGNETIC BASED RELEASE

WITH ADJUSTABLE OVERLOAD & SHORT CKT PROTECTION

PROVIDE RYB + ON,OFF&TRIP INDICATION LAMPS.

Price l 38

RATE AMOUNT RATE AMOUNT

INSTALLATIONAMOUNTQTYSR. NO. DESCRIPTION UNIT

SUPPLY

4 MCB/MCCB & DISTRIBUTION BOARDS:

4.1

Supplying and fixing following way, horizontal type three pole and neutral, sheet steel,

MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,

neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.

as required. (But without MCB/RCCB/Isolator)

4.1.1 8 way (4 + 24), Double door Nos. 4.00 4,601 18404.00 0.00 18404.00

4.2

Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V,

TPN MCB distribution board of sheet steel, dust protected, duly powder painted, Inclusive

of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting

MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is

normally used where 3 phase outlets are required.)

4.2.1 8 way (4 + 24), Double door Nos. 3.00 7,744 23232.00 0.00 23232.00

4.2.2 12 way (4 + 36), Double door Nos. 4.00 9,828 39312.00 0.00 39312.00

4.3

Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit

breaker suitable for inductive load of following poles in the existing MCB DB complete with

connections, testing and commissioning etc. as required.

4.3.1 Single pole Nos. 129.00 199 25671.00 0.00 25671.00

4.3.2 Double pole Nos. 1.00 556 556.00 0.00 556.00

4.3.3 Triple pole Nos. 12.00 826 9912.00 0.00 9912.00

4.3.4 Triple pole and neutral Nos. 8.00 1,092 8736.00 0.00 8736.00

4.3.5 Four pole Nos. 4.00 1,807 7228.00 0.00 7228.00

4.4

Supplying and fixing 40A to 63A rating, 240/415 V, 10 kA, "C" curve, miniature circuit

breaker suitable for inductive load of following poles in the existing MCB DB complete with

connections, testing and commissioning etc. as required.

4.4.1 Triple pole and neutral Nos. 10.00 2,606 26060.00 0.00 26060.00

4.4.2 Four pole Nos. 3.00 2,606 7818.00 0.00 7818.00

4.5

Supplying and fixing 80A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker

suitable for inductive load of following poles in the existing MCB DB complete with

connections, testing and commissioning etc. as required.

4.5.1 Four pole Nos. 1.00 10,356 10356.00 0.00 10356.00

4.6

Supplying and fixing following rating, double pole, (single phase and neutral), 240 V,

residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing

MCB DB complete with connections, testing and commissioning etc. as required.

4.6.1 25A Nos. 13.00 2,236 29068.00 0.00 29068.00

4.7

Supplying and fixing following rating, double pole, (single phase and neutral), 240 V,

residual current circuit breaker (RCBO), having a sensitivity current 100 mA in the existing

MCB DB complete with connections, testing and commissioning etc. as required.

4.7.1 40A Nos. 3.00 5,410 16230.00 0.00 16230.00

4.8

Providing and fixing following rating and breaking capacity and pole MCCB with

thermomagnetic release and terminal spreaders in existing cubicle panel board including

drilling holes in cubicle panel, making connections, etc. as required.

4.9 Surge Protection Device

4.9.1

Supplying, installation & marking of surge arrestor/ surge protection device at the main

distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three

phase and neutral

Nos. 3.00 19,419 58258.20 0.00 58258.20

4.9.2

Supplying, installation & marking of surge arrestor/ surge protection device at the sub main

distribution board after the incoming breaker of type 2 tested for Imax 40 kA for three

phase and neutral

Nos. 7.00 15,910 111368.18 0.00 111368.18

5 SWITCH BOXES & SWITCH SOCKET

5.1Supplying and fixing following modular switch/ socket on the existing modular plate &

switch box including connections but excluding modular plate etc. as required.

5.1.1 5/6 amps switch No. 99.00 85 8415.00 0.00 8415.00

5.1.2 15/16 A switch No. 30.00 132 3960.00 0.00 3960.00

5.1.3 3 pin 5/6 A socket outlet No. 61.00 111 6771.00 0.00 6771.00

5.1.4 6 pin 15/16 A socket outlet No. 18.00 175 3150.00 0.00 3150.00

5.1.5 Telephone socket outlet No. 14.00 119 1666.00 0.00 1666.00

5.1.6 RJ45 DATA SOCKET No. 14.00 612 8568.00 0.00 8568.00

5.1.7

Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth,

metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on

surface or in recess, with chained metal cover for the socket out

let and complete with connections, testing and commissioning etc. as required.

No. 15.00 1232.00 18480.00 0.00 18480.00

Price l 39

RATE AMOUNT RATE AMOUNT

INSTALLATIONAMOUNTQTYSR. NO. DESCRIPTION UNIT

SUPPLY

5.1.8

Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth,

metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on

surface or in recess, with chained metal cover for the socket out let and complete with

connections, testing and commissioning etc. as required.

No. 26.00 3048.00 79248.00 0.00 79248.00

5.2 CEILLING FAN AND EXHAUST FAN

5.2.1

Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated,

ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.

blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding,

Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery

minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%,

remote or electronic regulator unit for speed control and all remaining accessories

including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation

resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply,

earthing etc. complete as required.

No. 10.00 2,688 26880.00 0.00 26880.00

5.2.2 Supplying and fixing 510mm Exhaust fan including connections. No. 4.00 1,587 6348.00 0.00 6348.00

5.2.3Wall / Column Mounted Heavy Duty Industrial Almonard Fan.

(Makes-CGL / Khaitan).No. 9.00 11,040 99360.00 0.00 99360.00

5.2.4

Supplying and fixing two module stepped type electronic fan regulator on the existing

modular plate switch box including connections but excluding modular plate etc. as

required.

No. 10.00 342 3420.00 0.00 3420.00

5.2.5

Installation, testing and commissioning of ceiling fan, including wiring the down rods of

standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor,

single core cable etc. as required.

No. 10.00 171 1710.00 0.00 1710.00

5.2.6Installation of exhaust fan in the existing opening, including making good the damage,

connection, testing, commissioning etc. as required.

5.2.6.1 510 mm sweep No. 4.00 523 2092.00 0.00 2092.00

5.3Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate

for modular switches in recess etc. as required.

5.3.1 1 or 2 Module (75mmX75mm) No. 88.00 243 21384.00 0.00 21384.00

5.3.2 3 Module (100mmX75mm) No. 41.00 267 10947.00 0.00 10947.00

5.3.3 4 Module (125mmX75mm) No. 3.00 287 861.00 0.00 861.00

5.3.4 6 Module (200mmX75mm) No. 18.00 333 5994.00 0.00 5994.00

5.4Supplying and fixing following Modular base & cover plate on existing modular metal

boxes etc. as required.

5.4.1 1 or 2 Module No. 88.00 114 10032.00 0.00 10032.00

5.4.2 3 Module No. 41.00 128 5248.00 0.00 5248.00

5.4.3 4 Module No. 3.00 138 414.00 0.00 414.00

5.4.4 6 Module No. 18.00 167 3006.00 0.00 3006.00

6 CABLE SYSTEM.

Installation of cables along with associated work like sleeving for cable entry through wall /

slab / road crossing shall not be paid extra. The same shall be considered as cable laying

part of Power, control, earthing cable laying system activity. GI/Hume pipes rates shall be

considered extra.Supply and laying of HT cables in cable ducts/uPVC conduits as required and including

testing and commissioning of the following sizes of 11KV grade multicore

aluminium/copper conductor XLPE/PVC insulated and PVC sheathed armoured cable

conforming to IS : 7098 (Part-II)

6.1 HT cable.

Supply of PVC insulated and PVC sheathed / XLPE

power cable of 11 KV grade enearthed.

6.1.1 3C X 95Sq. mm. Al, 11 kV, Armoured XLPE (UE) Mtr. 50.00 1,084 54200.00 0.00 54200.00

6.2

Laying of one number PVC insulated and PVC sheathed / XLPE

power cable of 11 KV grade of following size direct in ground

including excavation, sand cushioning, protective covering and

refilling the trench etc as required.

6.2.1 Upto 120 sq. mm Mtr. 50.00 438 21900.00 0.00 21900.00

6.3 LT POWER AND CONTROL CABLES :

6.3.1Supply of 1.1KV Grade XLPE/PVC insulated copper/aluminium conductor steel of

armoured/unarmoured power cables as per the specs.

Supply and laying of LT cables in cable ducts/uPVC conduits as required and including

testing and commissioning of the following sizes of 1.1KV grade multicore

aluminium/copper conductor XLPE/PVC insulated and PVC sheathed armoured cable

conforming to IS : 7098 (Part-I) / IS : 1554 (Part-I).

6.3.1.1 1.5 mm² x 3C CU Armoured XLPE Cable Mtr. 2750.00 92 253000.00 0.00 253000.00

6.3.1.2 1.5 mm² x 4C CU Armoured XLPE Cable Mtr. 600.00 106 63600.00 0.00 63600.00

6.3.1.3 2.5 mm² x 4C CU Armoured XLPE Cable Mtr. 70.00 166 11620.00 0.00 11620.00

6.3.1.4 4 mm² x 4C CU Armoured XLPE Cable Mtr. 900.00 227 204300.00 0.00 204300.00

6.3.1.5 6 mm² x 4C CU Armoured XLPE Cable Mtr. 150.00 327 49050.00 0.00 49050.00

6.3.1.6 10 mm² x 4C CU Armoured XLPE Cable Mtr. 170.00 491 83470.00 0.00 83470.00

6.3.1.7 25 mm² x 3.5C AL Armoured XLPE Cable Mtr. 130.00 175 22750.00 0.00 22750.00

6.3.1.8 35 mm² x 3.5C AL Armoured XLPE Cable Mtr. 300.00 219 65700.00 0.00 65700.00

6.3.1.9 50 mm² x 3.5C AL Armoured XLPE Cable Mtr. 200.00 284 56800.00 0.00 56800.00

6.3.1.10 150 mm² x 3.5C AL Armoured XLPE Cable Mtr. 50.00 691 34550.00 0.00 34550.00

6.3.1.11 300 mm² x 3.5C AL Armoured XLPE Cable Mtr. 500.00 1,343 671500.00 0.00 671500.00

6.3.1.12 300 mm² x 3.5C AL Armoured XLPE Cable Mtr. 105.00 1,343 141015.00 0.00 141015.00

Price l 40

RATE AMOUNT RATE AMOUNT

INSTALLATIONAMOUNTQTYSR. NO. DESCRIPTION UNIT

SUPPLY

6.3.2

Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV

grade of following size direct in ground including excavation, sand cushioning, protective

covering and refilling the trench etc as required.

6.3.2.1 Upto 35 sq. mm Mtr. 5070.00 323 1637610.00 0.00 1637610.00

6.3.2.2 Above 35 sq. mm and upto 95 sq. mm Mtr. 200.00 338 67600.00 0.00 67600.00

6.3.2.3 Above 95 sq. mm and upto 185 sq. mm Mtr. 50.00 352 17600.00 0.00 17600.00

6.3.2.4 Above 185 sq. mm and upto 400 sq. mm Mtr. 605.00 396 239580.00 0.00 239580.00

6.4 CABLE END TERMINATION

6.4.1 HT Cable Termination.

supplying and making indoor cable end termination with heat shrinkable jointing kit

complete with all accessories including lugs suitable for following size of 3 core, XLPE

aluminium conductor cable of 11 KV grade as required :

6.4.1.1 95 sq. mm Nos. 6.00 8,900 53400.00 1466.00 8796.00 62196.00

6.4.2 LT Cable Termination.

Supplying and making end termination with brass compression gland and aluminium lugs

for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable

of 1.1 KV grade as required.

6.4.2.1 3 X 1.5 sq. mm Nos. 166.00 217 36022.00 89.00 14774.00 50796.00

6.4.2.2 3½ X 25 sq. mm (28mm) Nos. 4.00 250 1000.00 0.00 1000.00

6.4.2.3 3½ X 35 sq. mm (32mm) Nos. 12.00 300 3600.00 0.00 3600.00

6.4.2.4 3½ X 50 sq. mm (35mm) Nos. 4.00 329 1316.00 0.00 1316.00

6.4.2.5 3½ X 150 sq. mm (50mm) Nos. 4.00 555 2220.00 0.00 2220.00

6.4.2.6 3½ X 300 sq. mm (70mm) Nos. 12.00 936 11232.00 0.00 11232.00

6.4.2.7 3½ X 300 sq. mm (70mm) Nos. 2.00 936 1872.00 0.00 1872.00

6.4.2.8 4 X 10 sq. mm (25mm) Nos. 16.00 219 3504.00 0.00 3504.00

6.4.2.9 4 X 2.5 sq. mm Nos. 10.00 224 2240.00 89.00 890.00 3130.00

6.4.2.10 4 X 4 sq. mm Nos. 64.00 269 17216.00 89.00 5696.00 22912.00

6.4.2.11 4 X 6 sq. mm Nos. 10.00 344 3440.00 89.00 890.00 4330.00

6.4.3 Water Proof Termination

Supply, installation of FLP & WP terminations with Double compression type Brass-Nickel

cable gland , lugs & PVC Shrouds. The gland shall be provided with earth tag , ensures

earth continuity between gland and equipment, etc. complete as required.

6.4.3.1 4 X 1.5 sq. mm Nos. 232.00 535 124120.00 118.00 27376.00 151496.00

7 INTERNAL WIRING

7.1

Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS

PVC insulated copper conductor, single core cable in surface/ recessed medium class

PVC conduit as required.

7.1.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire Mtr. 5600.00 146 817600.00 0.00 817600.00

7.1.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Mtr. 1500.00 167 250500.00 0.00 250500.00

7.1.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Mtr. 400.00 200 80000.00 0.00 80000.00

8 LIGHT FITTING

Supply, Unloading, Installation, Testing & Commissioning of standard light fittings and

lighting accessories including lamp. The scope shall includes unpacking assembly of

luminaries, providing of all hardware such as chain, nuts, anchor fasteners, bolts, screws,

cleats, clamps, PVC insulated wires / cables from Junction box to lighting fixtures, ceiling

roses ball and socket 'arrangement with J.B., suspension conduit pipe 0.5 m long 19 mm

black MS conduit down rod for light fitting. The cost of fabrication and installation of

MS supports will be the part of this item only. The scope of work also includes any

modifications required to be carried out on the mounting bracket to suit mounting of light

fixtures & any modification inside control gear box / fixture for proper commissioning of

fixture.

All LED Fittings are with Driver, LED luminaries housing/body shall be pressure die cast

aluminium or extruded Aluminium or CRCA as specified along with finished powder

coating, complete with all accessories.

Price l 41

RATE AMOUNT RATE AMOUNT

INSTALLATIONAMOUNTQTYSR. NO. DESCRIPTION UNIT

SUPPLY

8.1

Fixture shall be supplied with the following along with mounting accessories:

- CRCA Powder coated with white housing

- Recess mounted

- Bottom Opening

- High efficacy long life LEDs

- Aesthetic CRCA powder coated bottom frame

- Special translucent high transmisivity, non yellowing HET diffuser

- Non-Integral multi stage CCCV electronic driver with 3kV surge protection. Driver shall

be pre wired upto the terminal block

- Confirms IS 10322 / Part 5 / sec 1 : 1987

- Suitable for 31 W LED (2x2)

- Suitable for 600MM X 600MM Cutout size in Calcium silicate / non walkable false ceiling.

- The LED source used shall be medium/high power complying with LM80 standards &

LED source efficacy >105 lm/w.

- LED lumen output of the luminaire of a minimum of 3000 lumens.

- Similar to Wipro make, CRCO10R038HP57G1

Immaculate+ : Recess Mounted 2ft x 2ft LED

Nos. 45.00 2,714 122130.00 354.00 15930.00 138060.00

8.2

Fixture shall be supplied with the following along with mounting accessories:

- High power, high efficiency Chip On Board(COB) LED module (medium/high power) only

complying with LM80 standards & LED source efficacy >100 lm/w - Surface

mounting type, Bottom Opening including all necessary hardwares/accessories

- High transmisivity, non yellowing PMMA diffuser

- Pressure die cast aluminium housing with special wave shaped radial fins, black powder

coated for superior thermal performance

- Specially designed, easy to install mounting clips

- Non-integral Driver with constant current constant voltage (CVCC), P.F >0.95 and

Surge Protection of atleast 2KV.Driver shall be pre wired upto the terminal block

- Suitable for 15 W LED downlighter

- LED lumen output of the luminaire of a minimum of 1500 lumens.

- Similar to Wipro make, LD06-171-XXX-57WSM

Nos. 14.00 1,696 23744.00 354.00 4956.00 28700.00

8.3

Fixture shall be supplied with the following along with mounting accessories:

- Surface mounting type including all necessary hardwares/accessories

- CRCA Powder coated housing

- Fitting should be with dust proof polycarbonate body, IP66 with frosted ends & gasket

polycarbonate diffuser with transparent prismatic interior & smooth exterior

- All other necessary Accessories

- Suitable for 40 W LED Industrial Capsule Type and outdoor application

- LED lumen output of the luminaire of a minimum of 4000 lumens.

- Similar to Wipro make, LE20-491-XXX-57-G1 Capsule LED

- IP65 Suface / Pendent Mounted LED Luminaries

Nos. 84.00 3,732 313488.00 354.00 29736.00 343224.00

8.4

Fixture shall be supplied with the following along with mounting accessories:

- Surface mounting type including all necessary hardwares/accessories

- CRCA Powder coated housing

- Fitting should be with polycarbonate body, IP40 with frosted ends & gasket

polycarbonate diffuser with transparent prismatic interior & smooth exterior

- All other necessary Accessories

- Suitable for 40 W LED Industrial Batten Type and outdoor application

- LED lumen output of the luminaire of a minimum of 4000 lumens.

- Similar to Wipro make, LL24R-541-XXX-57-CD Optima

LED Batten - 4FT LED Batten

Nos. 92.00 1,696 156032.00 354.00 32568.00 188600.00

8.5

Fixture shall be supplied with the following along with mounting accessories:

- Surface mounting Highbay type including all necessary hardwares/accessories

- High efficacy long life LEDs

- Special translucent high transmisivity, non yellowing PMMA diffuser

- Non-Integral multi stage CCCV electronic driver with 3kV surge protection. Driver shall

be pre-wired upto the terminal block

- Confirms IS 10322 / Part 5 / sec 1 : 1987

- Suitable for 120 WATT LED

- The LED source used shall be medium/high power complying with LM80 standards &

LED source efficacy >105 lm/w.

- LED lumen output of the luminaire of a minimum of 2100 lumens.

- Similar to Wipro make, WIPRO ENTERPRISES (P) LTD LH21-192-060-

57-XX UNO HIGHBAY LIGHT LUMINAIRE

Nos. 75.00 12,113 908475.00 531.00 39825.00 948300.00

8.6

Fixture shall be supplied with the following along with mounting accessories:

- Premium outdoor Under Water Light including all necessary hardwares/accessories

- High efficacy long life LEDs

- Suitable for 18 W LED Decorative under water Type

- The LED source used shall be medium/high power complying with LM80 standards &

LED source efficacy >105 lm/w.

- LED lumen output of the luminaire of a minimum of 1500 lumens.

- Similar to Wipro make, LU03-211-030-30-XX

Nos. 112.00 26,462 2963744.00 354.00 39648.00 3003392.00

9 EARTHING SYSTEMS

EARTHING STATIONS:

9.1

Price l 42

RATE AMOUNT RATE AMOUNT

INSTALLATIONAMOUNTQTYSR. NO. DESCRIPTION UNIT

SUPPLY

Supply, Installation of earth stations with necessary all materials, labour, excavation & all

civil works, etc. as per IS/IEC etc. Complete with all required hardware as mention below.

9.1.1

Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and

providing masonry enclosure with cover plate having locking arrangement and watering

pipe etc. with charcoal/ coke and salt as required.

Nos. 23.00 5,308 122084.00 0.00 122084.00

9.1.2

Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and

providing masonry enclosure with cover plate having locking arrangement and watering

pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as

required.

Mtrs. 4.00 5,146 20584.00 0.00 20584.00

9.1.3

Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and

providing masonry enclosure with cover plate having locking arrangement and watering

pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as

required.

Mtrs. 2.00 5,146 10292.00 0.00 10292.00

9.2 EARTHING STRIPs/WIREs:

Supply, laying of hot dipped galvanized (GI)/copper bare earth conductor bar / flexible

wire /strip of following sizes along the cable trenches or cable trays or fixing to walls or

structures or buried individually in paved/unpaved areas but excluding civil work finishing

after layering of earthing strips etc. The installation shall include welded joints with 4'' over

lapping of the strips. Welded joints shall be used for G.I. strips. Welded joints after welding

shall be painted with anticorrosive black bitumen paint , applying anti corrosive primer

paint and two coat each of bituminous paint for buried earth strip. Excavation & backfilling

of soil for burying the strip wherever applicable is paid extra as per the rate of excavation

and backfilling rate. Jumper 150 mm x 50 mm shall be provided at every 10 meter interval

for main earthing strip under instruction of engg. in charge and jumper rate paid extra.

9.2.1

Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth

electrode, including connection/terminating(Jointing shall be done by overlapping and with

welded joints with 4'' over lapping of the strips)

Mtrs. 1000.00 131 131000.00 0.00 131000.00

9.2.2Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc.

as required.Mtrs. 1186.00 206 244316.00 0.00 244316.00

9.3LIGHTNING PROTECTION SYSTEM (CONVENTIONAL LIGHTNING ARRESTOR):

Air Terminal ( Horizantal ) :

9.3.1

Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I.

tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes

etc.complete as required.

No. 5.00 448 2240.00 0.00 2240.00

9.3.2Fixing of lightning conductor finial (single prong) with base plate including holes etc.

complete as required.No. 5.00 280 1400.00 0.00 1400.00

9.3.3Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other

metallic object) by riveting / nut bolting/ sweating and soldering etc as required.No. 16.00 93 1488.00 0.00 1488.00

9.3.4Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for

lightning conductor complete as required.(For horizontal run)Mtrs. 1600.00 104 166400.00 0.00 166400.00

9.3.5Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for

lightning conductor complete as required.(For vertical run)Mtrs. 200.00 163 32600.00 0.00 32600.00

9.3.6Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long,

with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.Mtrs. 16.00 102 1632.00 0.00 1632.00

10 HOT DIPPED GALVANIZED IRON CABLE TRAYS

Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray

(Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%,

in convenient sections, joined with connectors, suspended from the ceiling with G.I.

suspenders including G.I. bolts & nuts, etc.as required.

10.1 CABLE TRAYS

10.1.1 100mm wide cable tray perforated type (1.6 mm thick & 50 mm high collar) Mtrs. 550.00 599 329450.00 0.00 329450.00

10.1.2 150mm wide cable tray perforated type (1.6 mm thick & 50 mm high collar) Mtrs. 30.00 644 19320.00 0.00 19320.00

10.1.3 300 mm wide cable tray perforated type (1.6 mm thick & 50 mm high collar) Mtrs. 65.00 875 56875.00 0.00 56875.00

10.1.4 450 mm wide cable tray perforated type (2 mm thick & 50 mm high collar) Mtrs. 40.00 1,213 48520.00 0.00 48520.00

10.1.5 600 mm wide cable tray ladder type (2 mm thick & 62.5 mm high collar) Mtrs. 25.00 1,752 43800.00 0.00 43800.00

10.1.6 750 mm wide cable tray ladder type (2 mm thick & 62.5 mm high collar) Mtrs. 3.00 2,079 6237.00 0.00 6237.00

11 INSTALLATION OF UPS SYSTEM

9.1

Price l 43

RATE AMOUNT RATE AMOUNT

INSTALLATIONAMOUNTQTYSR. NO. DESCRIPTION UNIT

SUPPLY

Unloading, Installation, testing & Commissioning of the following rating of UPS System

including unloading, transportation from store to site ,errection insulation, testing of UPS

System including Battery and Battery rack errection & Installation under the supervision of

supplier of UPS. The scope also includes supply and installation of the flexible wire from

SDF enclosure to UPS and UPS to Main UPS DB. Flexible wire shall be as per the

recommendation of UPS supplier.

11.1 UPS SYSTEM

11.1.1

Unloading at site, handling, erection, alignment and other associated work of 20 kVA UPS

under the supervision of supplier's commissioning engineer. UPS shall have three phase

input as well as output.

No. 1.00 356540.00 1180.00 1180.00 357720.00

11.2 ISOLATOR FOR UPS.

11.2.1

Supply, installation of 16 kA, 40A TP MCCB+N, with rotary handle in enclosure made up

of 1.6mm thick CRCA sheet, pretreated in seven tank process, powder coated with paint

thickness not less than 100 micron ( Shade RAL 7032 ). The MCCB shall be interlocked to

prevent the enclosure Door being opened unless the MCCB in OFF position and Also

Enclosure shall be provided with facilities for Padlocking in the OFF position Cable end

box shall be provided for incoming and outgoing cables.

Makes - Siemens / Schneider

No. 2.00 13,366 26732.00 413.00 826.00 27558.00

11.3Supply & installation of cable of suitable size from UPS isolator to UPS & from UPS to

isolator. (Distance Between Isolator to UPS & UPS to isolator will be max. 5 Mtr.)

11.3.1 4 Runs x 1 core x 6 mm² CU XLPE flexible leads for 20 KVA UPS Mtrs. 20.00 92 1840.00 33.00 660.00 2500.00

12 MISCELLANEOUS ITEMS :

12.1

Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2

coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at

the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including

inscription duly engraved as required.

Nos. 10.00 530 5300.00 0.00 5300.00

12.2

Supplying and fixing cable route marker with 10 cm X 10 cm X 5mm thick G.I. plate with

inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and

fixing the same in ground as required.

Nos. 10.00 383 3830.00 0.00 3830.00

12.3 Safety items

Safety Equipment's: Supply, Installation of below mention safety equipment including all

labour and materials etc., complete as per directions of Engineer-In-Charge.

12.3.1Sand buckets with floor stand and sand (set of 4 buckets of 9 Ltr. capacity) Stand size :

1.5 M x 0.9 M x 0.6 M stand shall be painted with epoxy paint as per IS requirement.Set 1.00 5,065 5065.00 118.00 118.00 5183.00

12.3.2 Caution boards ( 433V each) Nos. 1.00 407 407.00 118.00 118.00 525.00

12.3.3

Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at

least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single

red colour on front side as required.

Nos. 1.00 226 226.00 118.00 118.00 344.00

12.3.4 Rubber mats of 11 KV grade 2 Mtrs x 1 Mtrs x 6 mm Thick Nos. 2.00 2,578 5156.00 118.00 236.00 5392.00

12.3.5 Rubber Hand Gloves pair ( 11 KV Grade ) Nos. 1.00 760 760.00 118.00 118.00 878.00

12.3.6Shock treatment chart with teak wood frame and glass cover as approved by Electrical

Inspectorate. In English & Local language.Nos. 1.00 679 679.00 590.00 590.00 1269.00

12.3.7 First aid box with standard items Nos. 1.00 814 814.00 0.00 814.00

12.3.8 Dry powder type fire extinguisher of 5 Kg. Capacity Nos. 1.00 10,856 10856.00 118.00 118.00 10974.00

12.3.9

Supply, Installation of 4.5kg capacity CO2 type fire extinguishers complete with mounting

brackets, spray nozzles, connecting pipes, "OPEN/CLOSE" valves with all other

necessary accessories complete as required.

Nos. 1.00 4,750 4750.00 118.00 118.00 4868.00

12.3.10 Electrical single line diagram (As Built drawing) with teak wood frame and glass cover. Nos. 1.00 2,036 2036.00 118.00 118.00 2154.00

12.4 Structural Steel Fabrication

Supply, transport, unloading, shifting & Fabrication of steel sections and erection of MS

base frames, MS angle channels, flat etc. for supporting various items of equipment such

as various panels/switchgear, dummy panels, adaptor boxes addition support for proper

cable termination, MS Fabricated cable trays, push button stations, junction boxes, light

fittings, DB etc. The scope include welding, bolting, chipping , grouting etc., including

applying one antirust coat of approved primer and two finished coats of approved paint

with primer & paint, breaking and finishing of walls, floors etc. Contractor has to apply one

coat of antirust paint (Red-oxide ) before installation. The scope is inclusive of minor civil

work as required, supply of GI hardware materials, consumables, tools & tackles and

necessary labour with supervision but not limited to, and complete as per approved

drawings, specification and directions of Engineer-In charge. The scope also includes

transportation of material from owner’s issue point to actual place of work by contractor's

own lifting and transporting arrangement.

Tons 3.00 76,700 230100.00 24.00 72.00 230172.00

3,56,540

Price l 44

RATE AMOUNT RATE AMOUNT

INSTALLATIONAMOUNTQTYSR. NO. DESCRIPTION UNIT

SUPPLY

12.5

Making masonry cable trench with floor cutting making 5' inch wall (both side). Size 800

mm width X 800 mm depth x 3000 mm length for erection of 2 panel 11kV VCB on trench

and HT cable laying.

Mtr 4.00 2,931 11724.00 0.00 11724.00

12.6

Supply and Laying of 100mm dia class B G.I. pipe in underground trench, along walls for

cable protection.

Make: TATA. JINDAL, BANSAL

Mtr 60.00 1,065 63900.00 0.00 63900.00

13 Gripple Hangers System -

13.1 M10 Eyebolt with Nut & Washer (2 No Each) Nos. 36.00 94 3384.00 8.00 288.00 3672.00

13.2 M10 Nut & Washer (2No. Each) Nos. 36.00 15 540.00 8.00 288.00 828.00

13.3 GHF NO.4 LOOP WIRE 5.0 MTR Nos. 18.00 1,464 26352.00 120.00 2160.00 28512.00

TOTAL WITH TAX 1,50,58,429 2,89,391 1,53,47,820

Price l 45

A Hydrant System (Refer attached technical data sheets)

1

Supplying, fixing, testing and commissioning of The Pipes of sizes 150mm & below shall be

M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel

pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto

350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above

150 NB mtr 380 2,385.00 906300

80 NB mtr 30 1,432.24 42967

25 NB mtr 24 439.53 10549

-

2Supplying,testing, installing & commissioning of BUTTERFLY VALVE (MANUAL) with C I

body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified-

150 NB Nos 4 5,442.00 21768

-

3

Supply, fixing, testing and commissioning of Single headed SS-304 fire hydrant valve as

per IS: 5290 (ISI Marked Type-A) with 80 mm N.B. flanged inlet, brass spindle, 63 mm dia

instantaneous type SS. coupling blank cap & chain. Including tapping from wet riser

complete as required.

Nos 8 6,422.43 51379

-

4

Supply, fixing, testing and commissioning of swinging type First Aid hose reel in red

colour with 25mm dia x 30 mts long and below mentioned size heavy duty rubber water

hose terminating with ABS nozzle of 5 mm outlet with shut off valve as per IS: 8090 -

1976 complete with drum and brackets for fixing on walls, bolts & nuts conforming to IS:

884 (ISI Makred) complete as required. Nos

8 10,663.59 85309

-

5

Supply, fixing, testing and commissioning of RRL Hose pipe, 63 mm dia and 15 mts long,

conforming to IS: 636 Type-A (ISI marked) suitable for bursting pressure not less than

35.7 Kg/Sqcm. type A with SS-304 heavy duty instantaneous type coupling (Pair male &

female parts) conforming to IS: 903 (ISI makred).. Nos

16 5,933.34 94933

-

6

Supply, fixing, testing and commissioning of 63 mm dia instantaneous pattern branch

short SS-304 branch pipe as per IS: 903 (ISI marked) 20 mm dia nozzle, suitable for inter

connection to hose pipes coupling complete as required. Nos

8 2,259.81 18078

-

7

Supply, fixing, testing and commissioning of fire cabinet of size not less than 0.75 x 0.6 x

0.25 mtr made out of M.S. sheet not less than 1.5 mm thick having central opening and

4 mm thick glazed acryclic sheet doors (Two nos.) suitably marked on the outside 'with

the letters "FIRE HOSE" including necessary locking arrangement and painting in red

colour suitable to accommodate, 2 nos 15 mtr long Hose pipe, branch pipe, nozzle and

painted in red along with GI support angles for internal hydrants. Nos

8 6,500.97 52008

-

8

Supply, fixing, testing and commissioning of brass body Ball valve with lever of pressure

rating 300 PSIg, including providing necessary union/flange and making proper

connection.

-

25 NB Nos 8 680.98 5448

-

7 Supply, fixing of Fire man Axe Nos 8 751.49 6012

-

8

Structural steel work riveted, bolted or welded in built up sections, trusses and framed

work, including cutting, hoisting, fixing in position and applying a priming coat of approved

steel primer all complete.

Kgs 2000 101.75 203500

-

B Automatic Sprinkler System (Refer attached technical data sheets) -

-

1

Supplying, fixing, testing and commissioning of The Pipes of sizes 150mm & below shall be

M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel

pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto

350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above

-

80 NB mtr 72 1,432.24 103121

65 nB mtr 0 970.24

50 NB mtr 0 770.64

40 NB mtr 0 558.53

25 NB mtr 96 439.53 42195

-

2

Installation, testing, & commissioning of Quartzoid bulb Standard response, Standard

coverage sprinklers to be Operated at 68 Deg C, K80 FM Approved /UL Listed upright

type

Nos 35 551.57 19305

Fire protection and Alarm System.

RATE AMOUNTQTY SR. NO. DESCRIPTION UNIT

Price l 46

-

3

Supply, fixing, testing and commissioning of FM approved/ UL listed Alarm control valve

with automatic Alarm Gong to be connected with control valve, drain, test valve as

per manufacturer's specifications complete as required. Including matching flanges,

nut bolts, gaskets, etc.

-

80 NB Nos 1 33,076.76 33077

-

4

Supply, fixing, testing and commissioning of FM/UL listed Flow switch on sprinkler riser for

Aerosol area and shall be connected to fire alarm panel through cable. Cable shall be

measured seperately.

-

80 NB Nos 1 7,766.54 7767

-

5Supply, installation, testing and commissioning of IS 14846 OS & Y , Rising Spindle

Gate valve, PN 10, With flanges nut bolts, etc.-

80 NB Nos 1 10,699.29 10699

-

6

Supply, fixing, testing and commissioning of brass body Ball valve with lever of pressure

rating 300 PSIg, including providing necessary union/flange and making proper

connection.

-

25 NB Nos 2 680.98 1362

-

7

Structural steel work riveted, bolted or welded in built up sections, trusses and framed

work, including cutting, hoisting, fixing in position and applying a priming coat of approved

steel primer all complete.

Kgs 2000 101.75 203500

-

C Fire water Pumping System (Refer attached technical data sheets) -

-

1Supply, Installation Testing commissioning of End suction 96 m3/hr 70 m head, Main

electric Pump along with accessories. Nos 1 2,72,748.00 272748

-

2Supply, Installation Testing commissioning of End suction 96 m3/hr 70 m head, Diesel

Engine Standby Pump with fuel tank and other accessories Nos 1 5,68,893.78 568894

-

3Supply, Installation Testing commissioning of Vertical inline, Electric operated 10.8 m3/hr

70m head, Jockey pump with accessoriesNos 1 98,639.10 98639

-

4Supply, Installation Testing commissioning of MCC panel for above listed pumps as per

attached electrical single line diagram.Nos 1 2,24,088.90 224089

-

5

Supplying, fixing, testing and commissioning of The Pipes of sizes 150mm & below shall be

M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel

pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto

350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above

-

150 NB mtr 24 2,385.00 57240

100 NB mtr 24 1,784.00 42816

50 NB mtr 12 917.07 11005

40 NB mtr 12 664.65 7976

-

6Supply, installation, testing and commissioning of IS 14846 OS & Y , Rising Spindle

Gate valve, PN 10, With flanges nut bolts, etc.-

150 NB Nos 2 43,346.94 86694

100 NB Nos 2 25,012.85 50026

50 NB Nos 1 10,220.77 10221

40 NB Nos 1 8,566.22 8566

-

7

Supply, installation, testing and commissioning of NON - RETURN VALVE with dual

plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as

specified.

-

100 NB Nos 2 6,093.99 12188

40 NB Nos 1 7,309.86 7310

-

8 Supply, installation, testing and commissioning of Y type Strainer -

150 NB Nos 2 18,525.92 37052

50 NB Nos 1 6,310.57 6311

-

9

Structural steel work riveted, bolted or welded in built up sections, trusses and framed

work, including cutting, hoisting, fixing in position and applying a priming coat of approved

steel primer all complete.

kg 3000 101.75 305250

-

D Fire Extinguishers (Refer attached technical data sheets) -

1 FIRE EXTINGUISHER 9KG ABC TYPE Nos 0 3,409.50

-

2 FIRE EXTINGUISHER 6KG ABC TYPE Nos 11 2,827.44 31102

Price l 47

-

3 FIRE EXTINGUISHER 4.5KG CO2 TYPE Nos 3 7,841.51 23525

-

4 FIRE EXTINGUISHER 9LTR. FOAM TYPE Nos 1 2,827.44 2827

-

E Fire Alarm System

1

Supplying, installation, testing and commissioning of micro processor based intelligent

addressable main fire alarm panel, central processing unit with the following loop modules

and capable of supporting not less than 240 devices (including detectors) and minimum

120 detectors per loop and loop length up to 2 km, network communication card, minimum

320 character graphics/ LCD display with touch screen or other keypad and minimum 4000

events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50

hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.

The panel shall have facility to connect printer to printout log and facility to have seamless

integration with analog/digital voice evacuation system (which is part of the schedule of

work under SH: PA System) and shall be complete with all accessories . The panel shall be

compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per

specifications.Two Loop Panel.

nos 1 2,38,907.00 238907

2Supplying, installation, testing & commissioning of addressable manual call point complete

as required. Please refer attached technical data sheet.nos 8 3,859.00 30872

3Supplying, installation, testing & commisssioning of intelligent addressable programmable

sounder complete as required. Please refer attached technical data sheet.nos 8 2,638.00 21104

4

Supply, Installation, testing commissing of addressable Monitor Module,Operating

Temperature-20 ºC to +60 ºC with back box & mounting accessories. Please refer

attached technical data sheet.

nos 8 4,107.46 32860

5

Supply, Installation, testing commissing of Addressable Smoke Detector with built in LED,

mounting base complete with all connection etc. Please refer attached technical data

sheet.

nos 25 1,654.84 41371

6

Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC

with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete

with all connection etc. as required. Please refer attached technical data sheet.

nos 8 1,561.88 12495

7

Supplying, installation, testing & commissioning of addressable beam detector with short

circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections

with remote test features etc complete as required. Please refer attached technical data

sheet.

nos 4 74,778.00 299112

8Supplying, installation, testing & commissioning of fault isolator complete with base as

required.nos 4 3,257.00 13028

9

Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with

annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer

sheath complete as required.

Mtrs 1200 141.00 169200

-

F Spares -

-

1 FIRE EXTINGUISHER 6KG ABC TYPE Nos 1 4,416.80 4417

-

2 FIRE EXTINGUISHER 4.5KG CO2 TYPE Nos 1 12,439.31 12439

-

3

Supply of RRL Hose pipe, 63 mm dia and 15 mts long, conforming to IS: 636 Type-A

(ISI marked) suitable for bursting pressure not less than 35.7 Kg/Sqcm. type A with SS-

304 heavy duty instantaneous type coupling (Pair male & female parts) conforming to IS:

903 (ISI makred)..

Nos 2 11,042.01 22084

4Supplying, installation, testing & commissioning of fault isolator complete with base as

required.Nos 2 1,524.41 3049

5

Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with

annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer

sheath complete as required.

Nos 1 1,106.25 1106

TOTAL 4685797.30

Say, Rs. 4685797.00

Page l 48

1Supply, Installation, Testing & Commissioning of Negative suction pump-100m3/hr, VFD

18m-14m head with all accessories. Make of pumps- Kirloskar, Crompton.Nos 2 75826.8 151654

2Supply, Installation, Testing & Commissioning of MCC panel for 2 pumps. Refer attached

electrical single line diagram.Nos 1 61261.2 61261

3Supply, Installation, Testing & Commissioning of plastic Priming Tank 200 ltrs (Sintex or

equivalent)Nos 1 12637.8 12638

4

A/G Piping : Supplying, installing and testing & commissioning above ground Mild Steel

Galvanized Pipes of Heavy class ERW of following sizes conforming to IS 1239 C- class (&

IS 3589,6.35 mm thick) including painting with two coats of fire red enamel paint as per IS-

5 Shade 536, over a coat of epoxy primer as per specifications complete with and testing to

hydrostatic pressure of to 1.5 times the working pressure. All work shall be carried out as per

approved shop drawing, specifications and instruction of engineer in charge. Rate shall be

inclusive of fittings.150 NB mtrs 220 3802.05 836451

65 NB mtrs 18 1363.74 24547

50 NB mtrs 36 1078.14 38813

5Supply, installation, testing and commissioning of IS 14846 OS & Y , Rising Spindle

Gate valve, PN 10, With flanges nut bolts, etc. Refer attached technical data sheet.

150 NB Nos 2 26994.912 53990

100 NB Nos 2 15705.858 31412

6

Supplying, fixing, testing and commissioning of following sizes Motorized Butterfly Valve with

CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS

13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric

signal and providing similar transduced feedback output to control system as required. Refer

attached technical data sheet.65 NB Nos 4 16544 66176

7

Supplying,testing, installing & commissioning of BUTTERFLY VALVE (MANUAL) with C I

body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. Refer attached

technical data sheet.150 NB Nos 5 5442 27210

8Supplying,testing, installing & commissioning of Foot valves including nuts, bolts, neoprene

nitrile gasket, companion flanges etc.complete with all accessories. Refer attached technical

data sheet.150 NB Nos 2 5500.656 11001

50 NB Nos 2 2569.329 5139

9Supply, installation, testing and commissioning of NON - RETURN VALVE with dual

plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as

specified. Refer attached technical data sheet.100 NB Nos 2 4581 9162

50 NB Nos 1 5719.854 5720

10Supply, installation, testing and commissioning of Basket type Strainer including nuts,

bolts, neoprene nitrile gasket, companion flanges etc.complete with all accessories. Refer

attached technical data sheet.150 NB Nos 1 18052.062 18052

11Supply, fixing, testing and commissioning of brass body Ball valve with lever of pressure

rating 300 PSIg, including providing necessary union/flange and making proper connection.

Refer attached technical data sheet.

50 NB Nos 4 2542.554 10170

12Supply, installation, testing and commissioning of Monitor Module. Refer attached

technical data sheet.Nos 4 4230.45 16922

13

Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core

cable in the existing surface/ recessed steel/ PVC conduit as required. 2C x 1.5 sq. mm mtrs 1,200 41 49200

14Structural steel work riveted, bolted or welded in built up sections, trusses and framed work,

including cutting, hoisting, fixing in position and applying a priming coat of approved steel

primer all complete.

Kgs 3,000 101.75 305250

Water Transfer System

RATE AMOUNTQTY SR. NO. DESCRIPTION UNIT

Page l 49

RATE AMOUNTQTY SR. NO. DESCRIPTION UNIT

15Supply, installation, testing and commissioning of Radar type level Sensors. Refer

attached technical data sheet.Nos 4 249409.125 997637

16Supply, installation, testing and commissioning of Float type level Sensors. Refer

attached technical data sheet.Nos 8 31416 251328

17Supply, installation of LCD Display for level Sensors. 3 "x 1" Display. Letter size minimum

1". Make Epson, HP, equivalent.Nos 1 89999.7 90000

18

Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray

(Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in

convenient sections, joined with connectors, suspended from the ceiling with G.I.

suspenders including G.I. bolts & nuts, etc.as required.

100mm wide cable tray perforated type (1.6 mm thick & 50 mm high collar)

m 800 599 479200

19

Supplying and making end termination with brass compression gland and aluminium lugs for

following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1

KV grade as required.3 X 10 sq. mm (22mm) No 16 211 3376

20

Supply, installation of Filteration system including alum & hypo dosing & sand filters,

(CAPACITY 100 M3/HR), Operating Period-20 hrs. /day, ALUM DOISNG SYSTEM Capacity-

0-20 lit/hr @ 3 kg/cm2, HYPO DOISNG SYSTEM Capacity- 0-10 lit/hr @ 3 kg/cm2.

TREATED WATER QUALITY:

pH- 6.5 to 7.5.

Total Suspended Solid- 5 mg/lit

Nos 1 2531725 2531725

TOTAL 6088032.60

Say, Rs, 6088033.00

Page l 50

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

1

Demolishing brick work manually/ by mechanical means

including stacking of serviceable material and disposal of

unserviceable material within 50 metres lead as per direction of

Engineer-in-charge.In cement mortar.

cum 73.34 1469.90 107802.47

2

Demolishing R.C.C. work manually/ by mechanical means

including stacking of steel bars and disposal of unserviceable

material within 50 metres lead as per direction of Engineer - in-

charge.

cum 56.94 2534.70 144325.82

3

Dismantling cement asbestos or other hard board ceiling or

partition walls including stacking of serviceable materials and

disposal of unserviceable materials within 50 metres lead.sqm 62.17 42.00 2611.14

4

Earth work in excavation by mechanical means (Hydraulic

excavator) /manual means in foundation trenches or drains (not

exceeding 1.5 m in width or 10 sqm on plan), including

dressing of sides and ramming of bottoms, lift upto 1.5 m,

including getting out the excavated soil and disposal of surplus

excavated soil as directed, within a lead of 50 m. All kinds of

soil.

cum 56.81 252.30 14333.16

5

Filling available excavated earth (excluding rock) in trenches,

plinth, sides of foundations etc. in layers not exceeding 20cm in

depth, consolidating each deposited layer by ramming and

watering, lead up to 50 m and lift upto 1.5 m.

Cum 5.00 219.65 1098.25

6

Supplying and filling in plinth with sand under floors, including

watering, ramming, consolidating and dressing complete. Cum 24.53 1953.05 47908.32

7(i)1:3:6 (1 Cement : 3 coarse sand (zone-III):6 graded stone

aggregate 20 mm nominal size).cum 11.57 6126.25 70880.71

8

Providing and laying in position machine batched and machine

mixed design mix M-25 grade cement concrete for reinforced

cement concrete work, using cement content as per approved

design mix, including pumping of concrete to site of laying but

excluding the cost of centering, shuttering, finishing and

reinforcement, including admixtures In recommended

proportions as per IS: 9103 to accelerate, retard setting of

concrete, improve workability without impairing strength and

durability as per direction of Engineer-in-charge.(Note :-

Cement content considered in this item is 330 kg/cum. Excess/

less cement used as per design mix is payable/recoverable

separately).

All works upto plinth level cum 22.91 7997.30 183218.14

All works above plinth level upto floor V level cum 34.97 9400.85 328747.72

9Centering and shuttering including strutting, propping etc. and

removal of form for all heights.

Foundations, footings, bases of columns, etc. for mass

concrete sqm 27.50 284.85 7833.38

Demolition and Reconstruction:

Part A : Civil Works

Page l 51

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

Suspended floors, roofs, landings, balconies and access

platform sqm 145.00 693.05 100492.25

Lintels, beams, plinth beams, girders, bressumers and

cantilevers. sqm 111.10 552.05 61332.76

Columns, Pillars, Piers, Abutments, Posts and Struts sqm 53.25 733.70 39069.53

10

Steel reinforcement for R.C.C. work including straightening,

cutting, bending, placing in position and binding all complete

upto any level.Thermo-Mechanically Treated bars of grade Fe-

500D or more.

Kg 6945.60 83.50 579957.60

11

Brick work with clay fly ash F.P.S. (non modular) brick of class

designation 7.5 in superstructure above plinth level up to floor

five level in :Cement mortar 1:6 (1 cement : 6 coarse sand) cum 52.42 7752.90 406407.02

12

Supplying fitting and fixing of Hexagonal Chicken Mesh of

approved quality with necessary nails etc.at all levels & in any

floor complete in all respect. as per instruction of Engineer in

charge.

sqm 510.10 30.30 15456.03

13Cement plaster in course sand with 20 mm cement plaster of

mix (i) 1:4 (1 cement: 4 coarse sand)sqm 510.10 379.70 193684.97

14

Providing and fixing Ist quality ceramic glazed wall tiles

conforming to IS: 15622 (thickness to be specified by the

manufacturer), of approved make, in all colours, shades except

burgundy, bottle green, black of any size as approved by

Engineer-in-Charge, in skirting, risers of steps and dados, over

12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse

sand) and jointing with grey cement slurry @ 3.3kg per sqm,

including pointing in white cement mixed with pigment of

matching shade complete.

sqm 32.76 1030.30 33752.63

15

Providing and laying Vitrified tiles in different sizes (thickness to

be specified by manufacturer), with water absorption less than

0.08 % and conforming to I.S. 15622, of approved make, in all

colours & shade, in skirting, riser of steps, over 12 mm thick

bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing

with grey cement slurry @ 3.3kg/sqm including grouting the

joint with white cement & matching pigments etc.

complete.Size of Wall Tile 600x600 mm

sqm 71.68 1030.30 73851.90

Page l 52

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

16

Providing and fixing mineral fibre false ceiling tiles at all heights

of size 595X595mm of approved texture, design and pattern.

The tiles should have Humidity Resistance (RH) of 99%, Light

Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057

w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true

horizontal level suspended on

interlocking T-Grid of hot dipped all round galvanized iron

section of 0.33 mm thick (galvanized @120 gsm) comprising of

main T runners of 15x32 mm of length 3000 mm, cross T of

size 15x32mm of length 1200 mm and secondary intermediate

cross T of size 15x32 mm of length 600 mm to form grid

module of size 600x600 mm suspended from ceiling using

galvanized mild steel item (galvanised@80gsm)

50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm

diameter fully threaded hanger rod up to 1000 mm length and L-

shape level

adjuster of size 85x25x2 mm, spaced at 1200 mm centre to

centre along main ‘T’. The system should rest on periphery

walls /partitions with the help of GI perimeter wall angle of

size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed

to the wall with help of plastic rawl plug at 450 mm centre to

centre & 40 mm long dry wall S.S.

screws. The exposed bottom portion of all T-sections used in

false ceiling support system shall be pre-painted with polyester

baked paint, for all heights. The work shall be carried out as per

specifications, drawings and as per directions of the engineer-

incharge.

With 16 mm thick beveled tegular mineral fibre false ceiling tile

(NRC 0.55 to 0.6)sqm 64.80 2000.85 129655.08

17(a)

Providing and fixing factory made uPVC door frame made of

uPVC extruded sections having an overall dimension as below

(tolerance±1mm), with wall thickness 2.0 mm (± 0.2 mm),

corners of the door

frame to be Jointed with galvanized brackets and stainless

steel screws, joints mitred and Plastic welded. The hinge side

vertical of the frames reinforced by galvanized M.S. tube of size

19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos.

stainless steel hinges fixed to the frame complete as per

manufacturer’s specification and direction of Engineerin-

charge(i).Extruded section profile size 48x40 mm

meter 10.10 221.65 2238.67

Page l 53

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

17(b)

30 mm thick factory made Polyvinyl Chloride (PVC) door

shutter made of styles and rails of a uPVC hollow section of

size 60x30 mm and wall thickness 2 mm (± 0.2 mm), with

inbuilt decorative moulding edging on one side. The styles and

rails mitred and joint at the corners by means

of M.S. galvanised/ plastic brackets of size 75x220 mm having

wall thickness 1.0 mm and stainless steel screws. The styles of

the shutter

reinforced by inserting galvanised M.S. tube of size 25x20 mm

and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of

'H' section, a

uPVC hollow section of size 100x30 mm and 2 mm (± 0.2 mm)

wall thickness fixed to the shutter styles by means of plastic/

galvanised

M.S. 'U' cleats. The shutter frame filled with a uPVC multi-

chambered single panel of size not less than 620 mm, having

over all thickness of

20 mm and 1 mm (± 0.1 mm) wall thickness . The panels filled

vertically and tie bar at two places by inserting horizontally 6

mm galvanised M.S. rod and fastened with nuts and washers,

complete as

per manufacturer's specification and direction of Engineer-in-

charge.

sqm 3.15 1978.65 6232.75

18

Providing and applying white cement based putty of average

thickness 1 mm, of approved brand and manufacturer, over the

plastered wall surface to prepare the surface even and smooth

complete.

sqm 147.43 115.15 16976.56

19

Applying one coat of water thinnable cement primer of

approved brandand manufacture on wall surface Water

thinnable cement primer

Sqm 147.43 60.00 8845.80

20

Wall painting with premium acrylic emulsion paint of interior

grade, having VOC (Volatile Organic Compound ) content less

than 50 grams/ litre of approved brand and manufacture,

including applying additional coats wherever required to

achieve even shade and colour. Two coats

Sqm 147.43 113.90 16792.28

21

Finishing walls with Acrylic Smooth exterior paint of required

shade: Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm)

on existing cement paint surface

Sqm 60.00 164.70 9882.00

22

Finishing walls with Acrylic Smooth exterior paint of required

shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm

over and including priming coat of exterior primer applied @

2.20 kg/10 sqm)

Sqm 137.41 164.70 22631.43

23

Painting with synthetic enamel paint, having VOC (Volatile

OrganicCompound) content less than 150 grams/ litre, of

approved brand and manufacture, including applying additional

coats wherever required to achieve even shade and colour.

Two coats

Sqm 5.40 75.00 405.00

Page l 54

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

24(a)

Providing and fixing factory made ISI marked steel glazed

doors, windows and ventilators, side /top /centre hung, with

beading and all members

such as F7D, F4B, K11 B and K12 B etc. complete of standard

rolled steel sections, joints mitred and flash butt welded and

sash bars tenoned and riveted, including providing and fixing of

hinges, pivots, including priming coat of approved steel primer,

but excluding the cost of other fittings, complete all as per

approved design, (sectional weight of only steel members shall

be measured for payment). Fixing with 15x3 mm lugs 10 cm

long embedded in cement concrete block 15x10x10 cm of C.C.

1:3:6 (1 Cement : 3 coarse

sand : 6 graded stone aggregate 20 mm nominal size) Window

kg 60.00 166.50 9990.00

(b)

Providing and fixing M.S. grills of required pattern in frames of

windows etc. with M.S. flats, square or round bars etc. including

priming coat

with approved steel primer all complete.Fixed to steel windows

by welding

kg 86.40 165.30 14,281.92

25(a)

Providing and fixing IS : 12817 marked stainless steel butt

hinges with stainless steel screws etc. complete :75x47x1.80

mm

each 8.00 56.60 452.80

(b)

Providing and fixing aluminium handles, ISI marked, anodised

(anodic coating not less than grade AC 10 as per IS : 1868)

transparent or dyed

to required colour or shade, with necessary screws etc.

complete :100 mm

each 8.00 52.85 422.80

(c)

Providing and fixing aluminium tower bolts, ISI marked,

anodised (anodic coating not less than grade AC 10 as per IS :

1868 ) transparent or dyed

to required colour or shade, with necessary screws etc.

complete :100x10 mm

each 4.00 58.15 232.60

(d)

Providing and fixing aluminium sliding door bolts, ISI marked

anodised (anodic coating not less than grade AC 10 as per IS :

1868), transparent or dyed to required colour or shade, with

nuts and screws

etc. complete :250x16 mm

each 4.00 231.70 926.80

Page l 55

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

26(a)

Providing and fixing aluminium work for doors, windows,

ventilators and partitions with extruded built up standard tubular

sections/ appropriate Z sections and other sections of approved

make conforming to IS: 733 and IS: 1285, fixing with dash

fasteners of required dia and size, including necessary filling up

the gaps at junctions, i.e. at top, bottom and sides with required

EPDM rubber/ neoprene gasket etc. Aluminium sections shall

be smooth, rust free, straight, mitred and jointed mechanically

wherever required including cleat angle, Aluminium snap

beading for glazing / paneling, C.P. brass / stainless steel

screws, all complete as per architectural drawings and the

directions of Engineer-in-charge. (Glazing, paneling and dash

fasteners to be paid for separately) :Powder coated aluminium

(minimum thicknessof powder coating 50 micron) Frame .

kg 500.00 456.30 228150

(b)

For shutters of doors, windows & ventilators including

providing and fixing hinges/ pivots and making provision for

fixing of fittings wherever required including the cost of EPDM

rubber / neoprene gasket required (Fittings shall be paid for

separately) Powder coated aluminium (minimum thickness of

powder coating 50 micron).

kg 80.00 546.35 43708.00

(c)

Providing and fixing 12 mm thick prelaminated particle board

flatpressed three layer or graded wood particle board

conforming to IS: 12823 Grade l Type ll, in panelling fixed in

aluminum doors, windows shutters and partition frames with

C.P. brass / stainless steel screws etc. complete as per

architectural drawings and directions of Engineer-in-charge.

Pre-laminated particle board with decorative lamination on both

sides.

sqm 35.00 1046.90 36641.50

Providing and fixing glazing in aluminium door, window,

ventilatorshutters and partitions etc. with EPDM rubber /

neoprene gasket etc. complete as per the architectural

drawings and the directions

of Engineer-in-charge With float glass panes of 5.50 mm

thickness plain / frosted

sqm 15.00 1296.40 19446.00

Page l 56

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

27

Providing and laying APP (Atactic Polypropylene Polymer)

modified prefabricated five layer 3 mm thick water proofing

membrane, black finished reinforced with non-woven polyester

matt consisting of a coat of bitumen primer for bitumen

membrane @ 0.40 litre/sqm by the same membrane

manufacture of density at 25°C, 0.87-0.89 kg/

litre and viscocity 70-160 cps. Over the primer coat the layer of

membrane shall be laid using Butane Torch and sealing all

joints etc, and preparing the surface complete. The vital

physical and chemical parameters of the membrane shall be as

under : Joint strength in longitudinal and transverse direction at

23°C as 650/ 450N/5cm. Tear strength in longitudinal and

transverse direction as 300/250N. Softening point of membrane

not less than 150°C. Cold flexibility shall be upto -2°C when

tested in accordance with ASTM, D - 5147. The laying of

membrane shall be got done through the authorised applicator

of the manufacturer of membrane :3 mm thick

sqm 98.13 512.95 50335.78

28

Providing and fixing stainless steel ( Grade 304) railing made

of Hollow tubes, channels, plates etc., including welding,

grinding, buffing, polishing and making curvature (wherever

required) and fitting the same withnecessary stainless steel

nuts and bolts complete, i/c fixing the railing with necessary

accessories & stainless steel dash fasteners , stainless steel

bolts etc., of required size, on the top of the floor or the side of\

waist slab with suitable arrangement as per approval of

Engineer-incharge, (for payment purpose only weight of

stainless steel members shall be considered excluding fixing

accessories such as nuts, bolts, fasteners etc.).

Kg 160.00 575.45 92072.00

29

Disposal of building rubbish / malba / similar unserviceable,

dismantled or waste materials by mechanical means, including

loading, transporting, unloading to approved municipal

dumping ground or as approved by Engineer-in-charge, beyond

50 m initial lead, for all leads including all lifts involved.

Cum 133.39 138.85 18521.20

3141604.77

1Dismantling E.P. or Anglo-Indian W.C.

Each 1.00 53.55 53.55

2 Dismantling urinal. Each 2.00 39.27 78.54

3Dismantling wash basin with brackets with or without waste

fittings.Each 2.00 41.65 83.30

4

Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)

pipes, having thermal stability for hot & cold water supply,

including all

CPVC plain & brass threaded fittings, including fixing the pipe

with clamps at 1.00 m spacing. This includes jointing of pipes &

fittings with one step CPVC solvent cement and testing of joints

complete as per direction of Engineer in Charge..

Sanitary & Plumbing

Page l 57

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

i) 25 mm nominal outer dia Pipes metre 50.00 369.20 18460.00

ii) 15 mm nominal outer dia Pipes metre 15.00 241.55 3623.25

5Providing and fixing gun metal gate valve with C.I. wheel of

approved quality (screwed end) :

(a) 25 mm nominal bore Each 04 428.20 1712.80

6

A) Supplying, fitting & fixing UPVC pipes A- Type and fittings

conforming to IS:13592-1992 with all necessary clamps nails,

including making holes in walls, floor etc. cutting trenches in

any soil through masonry concrete structures etc if necessary

and mending good damages including joining with jointing

materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.

a) 110 mm. Dia. metre 64.00 298.69 19116.16

b) 75 mm. Dia. metre 25.00 223.72 5593.00

7

(c) Supply of UPVC pipes (B Type) & fittings conforming to IS

13592-1992. Plain Floor Trap with Top tile & Strainer.75 mm Nos 10 203.49 2034.90

8

Providing and fixing White vitreous china extended wall

mounting closet of size 710x 370x 770 mm of approved shape

including providing & fixing white vitreous china cistern with

dual flush,seat cover & fiting,of flusing capacity and cistern

fittings,nuts,bolts and gasket ctc complete. (Cat no : CRUSE -

Cat No : S1012135 Strap 300mm ,Cat No : B1520110 of

CERA make or equivalent)

Each 1.00 14155.00 14155.00

9

Supplying,fitting and fixing Flat back urinal (half stall urinal) in

white vitreous chinaware of approved make in position with

brass screws on 75 mm x 75mm x75mm wooden blocks

complete. 345mm x280mm x690 ( Cat No : 96008 of

HINDWARE make or equivalent)

Each 2.00 8586.00 17172.00

10

Supplying, fitting and fixing urinal flush pipe fittings of approved

brand.C.P. urinal flush pipe fittings range of one(Urinal Valve

auto closhing system with built in control cock & wall flange

No:( PRS-077 of JAQUAR)

Nos. 02 3026.00 6052.00

11

Providing and fixing PTMT 15 mm Urinal spreader size

95x69x100 mm with 1/2" BSP thread and shapes, weighing not

less than 60 gms.

Each 2.00 106.50 213.00

12

Supplying, fitting and fixing white vitreous china best quality

approved make wash basin with C.I. brackets on 75 mm X 75

mm wooden blocks with C.P. nut 32 mm dia. and painting the

brackets with two coats of approved paint. 580 mm X 450 mm

size.(PARRYWARE ,CARDIFF, Cat No : C0480(SP)/81(CTH)

Basin ,Cat No : C0375 Pedestal or equivalent )

Nos. 02 5211.00 10422.00

13

Supplying, fitting and fixing pillar Cock (Auto closhing System

with built in control cock with wall flange) (Model No. PRS-031

of JAQUAR make or equivalent).

Nos. 02 2223.00 4446.00

14

Supplying, fitting and fixing Chromium plated angular Stop

Cock with wall flange (CAT. No. CQT23059 of JAQUAR make

or equivalent).

Nos. 06 894.00 5364.00

Page l 58

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

15

Supplying, fitting and fixing two way Bib Cock with wall flange

(CAT. No. CQT23041 of JAQUAR make or equivalent). Each 2 1185.00 2370.00

16

Supplying, fitting and fixing Chromium plated Hand

shower(Health Faucet) with Flexible Tube with long1 mtr&wall

hook (CAT. No. ALD563 of Jaquar make or equivalent).Nos. 01 1301.00 1301.00

17

Supplying, fitting and fixing Single Towel Rail 450mm long

(CAT. No.. : ACN- 1111BNM of JAQUAR make or

equivalent)

Nos. 02 1315.00 2630.00

18

Supplying, fitting and fixing of Double coat Hook with Brush

screw.(CAT. No.. : ACN- 1161N of JAQUAR make or

equivalent)

Each 1 546.00 546.00

19

Providing and fixing PTMT liquid soap container 109 mm wide,

125 mm high and 112 mm distance from wall of standard

shape with bracket of the same materials with snap fittings of

approved quality and colour, weighing not less than 105 gms.

Each 3 137.85 413.55

20

Supplying, fitting and fixing porcelain toilet paper holder(Toilet

paper roll holder ) l (Cat No. : ACN-1155N of JAQUAR make

or equivalent)

Each 01 575.00 575.00

21

Providing and fixing PTMT Bottle Trap for Wash basin and

sink. Bottle trap 38 mm single piece moulded with height of 270

mm, effective length of tail pipe 260 mm from the centre of the

waste coupling, 77 mm breadth with 25 mm minimum water

seal, weighing not less than 263 gms

Each 4.00 348.60 1394.40

22

Providing and fixing 600x450 mm beveled edge mirror of

superior glass (of approved quality) complete with 6 mm thick

hard board ground fixed to wooden cleats with C.P. Brass

screws and washers complete.

Each 2 1283.05 2566.10

23

Supplying,fitting and fixing approved brand P.V.C.

CONNECTOR white flexible, with both ends coupling with

heavy brass C.P. nut, 15 mm dia. (v) 900 mm long

Each 5 174.93 874.65

Page l 59

Sl.

No.Description of items Unit Qty Rate(Rs.)

Amount

(Rs.)

24

Constructing Inspection pit of inside measurement 600mm X

600mm X upto 600mm (depth) with 250 mm thick 1st. class

brick work in cement mortar (1:4) on all sides, bottom of the pit

consisting of 100 mm thick cement concrete (1:3:6) with stone

chips over a layer of jhama brick flat soling,15 mm thick (1:4)

cement plaster to inside walls and out-side walls upto G.L. and

20 mm.thick (1:4) plaster to bottom of the pit, providing

necessary invert with cement concrete (1:3:6) with stone chips

as per direction, neat cement finishing to entire internal

surfaces, top of the pit covered with 100 mm thick R.C.C. slab

(1:1.5:3) with stone chips and necessary reinforcements upto

1% and shuttering including 6 mm thick cement plaster (1:4) in

all external surfaces of the slab and one 560 mm dia. R.C.C.

manhole cover of approved make supplied, fitted and fixed in

the slab with necessary fittings, necessary earthwork in

excavation in all sorts of soil, filling sides of the pit with earth

and removing spoils after work complete in all respect with all

costs of labour and materials.With Pakur variety.

Each 03 8421.63 25264.89

25

Providing and fixing 18 mm thick gang saw cut, mirror

polished,premoulded and prepolished, machine cut for kitchen

platforms, vanity counters, window sills, facias and similar

locations of required size,approved shade, colour and texture

laid over 20 mm thick base cement mortar 1:4 (1 cement : 4

coarse sand), joints treated with white cement,mixed with

matching pigment, epoxy touch ups, including rubbing, curing,

moulding and polishing to edges to give high gloss finish etc.

complete at all levels. Udaipur green marble/ Zebra black

marble Area of slab upto 0.50 sqm

sqm 5.00 2777.40 13887.00

26 Supplying, fitting and fixing S.S round grating.100 mm. Each 4 73.78 295.12

27

Providing and fixing PTMT Waste Coupling for wash basin and

sink, of approved quality and colour. Waste coupling 38 mm dia

of 83 mm length and 77mm breadth, weighing not less than 60

gms

Each 4 118.50 474.00

161171.21

3302775.98

33,02,776.00

Part (B) Rs.

Total (A+B) Rs.

Say Rs.

Page l 60

Summary Sheet

Sr. No Item Decription

1 Civil & structural

2 Plumbing

3 HVAC

4 Electrical

5 Fire protection & alarm

6 Water transfer system

7 Demolition & reconstruction

GRAND TOTAL

6088033

3302776

204797150

Cost Estimate

174605290

360097

407337

15347820

4685797

Page 61

FIRST FLOOR PLAN (+4.20m LVL.)

VOID

ROOF

SLO

PEDO

WN

1:7

ROOF

SLO

PEDO

WN

1:7

ROOF

SLO

PEDO

WN

1:7

600060006000600060006000600060006000600060006000600060006000600060006000 48004600 4600 6760 4830 4830

7150

6250

6250

6750

5850

6000

4230

4653

6200

6422

6424

A

A

F

F

VOID

RCC T

IE BE

AM

RCC T

IE BE

AM

RCC T

IE BE

AM

VOID VOID VOID

RCC T

IE BE

AM

RCC T

IE BE

AM

RCC T

IE BE

AM

RCC T

IE BE

AM

RCC T

IE BE

AM

RCC T

IE BE

AM

2.50m WIDE CHHAJJA / ROOF

FL +5.20 M

UP

PANELS

UP

D6 D6R=168T=280

DN

STAIRVOID

B

B

C

C

D

D

E

E

GG

FIREEXTINGUISHERS

PUMP ROOM18.37m x 6.80m

PANE

L ROO

M3.

10m

x 6.

80m

INSTRUMENTATIONROOM

RAMP UPSLOPE 1:10

FORKLIFTBATTERY

CHARGINGAREA

VERT

ICAL

PER

FORA

TED

SHEE

TS

GROUND FLOOR PLAN

STAIRVOID

R=175T=280

DN

WAL

L MO

UNTE

D AI

R CU

RTAI

N

WAL

L MO

UNTE

D AI

R CU

RTAI

N

WATERFILTRATION

SYSTEM

ACCESS LADDER

servi

ce du

ct

FLOOR CUTOUT WITH HEAVY DUTY MS COVERS

600x600 FLOOR CUTOUT WITH HEAVYDUTY MS COVER

Ø 100 PVC VENT PIPE WITH VENT COWL (ONEFOR EACH COMPARTMENT OF STORAGE TANK)

ED

RS

D1

D2 D4 D4

EXISTING DOOR

D4

D4 D2 D2

D3

600060006000600060006000600060006000600060006000600060006000600060006000 48004600 4600 6760 4830 4830

7150

6250

6250

6750

5850

6000

4230

4653

6200

6422

6424

A

A

F

F

STORM WATER DRAIN

W1

D3D3D3D3

MODEL MAKING AREA

LIF

TING

BEAM

3D PRINTING ROOM

PLA

METAL

PVC CURTAIN PVC CURTAIN

UP

SINK

ED

D3

D2

W1

LASER CUTTINGROOM

WC

WC

UR

UR

JANITOR

WB

WB

GENTS TOILET

WC

JANITOR

TOILET FORPHYSICALLY

CHALLANGED

WB

WB

LADIES TOILET

2.4 m WIDEPASSAGE

UP

SERVICE DUCT

UR

WC

D5

D4T

D6 D6D6 D6D6 D6

D3TD4T

UP

PORCH

R=167T=300

CEILING MOUNTED AIR CURTAIN

D3

OFFICE

RAMP UPSLOPE 1:10

R=153T=300

R=153T=300

SD1

D3

R=187.5T=270

DN

trenc

h

servi

ce du

ct

trenc

h

trenc

h

UP

- 1.50 M LVL

+ 0.00 M LVL

+ 0.00 M LVL

+ 0.00 M LVL

UPR=153T=300

FIRE PUMPS ROOM

DRINKING WATER

R=168T=280

UP

B

B

C

C

D

D

E

E

GGD3

STORE ROOMbelow

staircase

WALL MOUNTED· HOSE REEL· HOSE BOX· SINGLE HYDRANT VALVE

WALL MOUNTED· HOSE REEL· HOSE BOX· SINGLE HYDRANT VALVE

WALL MOUNTED· HOSE REEL· HOSE BOX· SINGLE HYDRANT VALVE

WALL MOUNTED· HOSE REEL· HOSE BOX· SINGLE HYDRANT VALVE· FIRE EXTINGUISHERS

FIREEXTINGUISHER

WALL MOUNTED· HOSE REEL· HOSE BOX· SINGLE HYDRANT VALVE· FIRE EXTINGUISHERS

WALL MOUNTED· HOSE REEL· HOSE BOX· SINGLE HYDRANT VALVE

WALL MOUNTED· HOSE REEL· HOSE BOX· SINGLE HYDRANT VALVE· FIRE EXTINGUISHERS

WALL MOUNTED· HOSE REEL· HOSE BOX· SINGLE HYDRANT VALVE

PVC CURTAIN PVC CURTAIN

CHAMBER

CHAMBER

SECTION G-G

FRONT ELEVATION

DEPARTMENT OF OCEAN ENGINEERING AND NAVAL ARCHITECTURE

SECTION A-A

PVC VENTCOWL

PVC VENT PIPE(TWO FOR EACH

COMPARTMENT OFSTORAGE TANK)

+5.80m LVL

+3.20m LVL

APPROX.

APPROX.

SECTION F-F

PVC VENTCOWL

PVC VENT PIPE(TWO FOR EACH

COMPARTMENT OFSTORAGE TANK)

+4.30m LVL

INSTRUMENTATIONROOM

STORM WATERDRAIN

APPROX.

ROOF SLOPE 1:20

ROOF SLOPE 1:20

SECTION B-B

PVC VENTCOWL

PVC VENT PIPE(TWO FOR EACH

COMPARTMENT OFSTORAGE TANK)

+6.40m LVL

+7.65m LVL

SLOP

E

SLOP

E

APPROX.

APPROX.

SLOP

E

SLOP

E

LASER CUTTINGROOM

ROOF SLOPE 1:20

SECTION C-C

PVC VENTCOWL

PVC VENT PIPE(TWO FOR EACH

COMPARTMENT OFSTORAGE TANK)

+7.65m LVL

+6.75m LVL

MODEL MAKING AREA

APPROX.

APPROX.

ROOF SLOPE 1:20

SECTION D-D

PVC VENTCOWL

PVC VENT PIPE(TWO FOR EACH

COMPARTMENT OFSTORAGE TANK)

+7.65m LVL

+4.30m LVL

MODEL MAKING AREA PVC CURTAIN

APPROX.

APPROX.

ROOF SLOPE 1:20

+7.65m LVL

PUMP ROOM

SECTION E-E

PVC VENTCOWL

PVC VENT PIPE(TWO FOR EACH

COMPARTMENT OFSTORAGE TANK)

MODEL MAKINGAREA

APPROX.

ROOF SLOPE 1:20

HEADER PIPE

HEADER PIPE HEADER PIPE

FIRE PUMPS

RCC

COLU

MN

RCC

COLU

MN

SUMP

RCC

COLU

MN

RCC

COLU

MN

SUMP

RCC

COLU

MN

RCC

COLU

MN

SUMP

RCC

COLU

MN

RCC

COLU

MN

SUMP

RCC

COLU

MN

RCC

COLU

MN

SUMP

RCC

COLU

MN

RCC

COLU

MN

SUMP

ROOF PLAN

500

500 500

500

TRUS

S

600060006000600060006000600060006000600060006000600060006000600060006000 48004600 4600 6760 4830 4830

6250

6250

6750

5850

6000

ROOF

SLO

PEDO

WN

1:7

ROOF

SLO

PEDO

WN

1:7

ROOF

SLO

PEDO

WN

1:7

ROOF

SLO

PEDO

WN

1:7

RIDG

E (+

6.40

m F

ROM

FFL

APP

ROX.

)

ROOFSLOPE

ROOFSLOPE

RIDGE (+5.80m FROM FFL APPROX.)

ROOF

SLOP

ERO

OFSL

OPE

ROOF

SLOP

ERO

OFSL

OPE

ROOF

SLOP

ERO

OFSL

OPE

ROOF

SLOP

ERO

OFSL

OPE

ROOF

SLOP

ERO

OFSL

OPE

ROOF

SLOP

ERO

OFSL

OPE

EAVE (+3.20m FROM FFL APPROX.)

OPEN TERRACE(@ +4.30m FROM FFL APPROX.)

OPEN TERRACE(@ +7.65m FROM FFL APPROX.)

FLAT ROOF(@ +6.75m FROM

FFL APPROX.)

A

A

ROOF

SLO

PEDO

WN

1:20

ROOF

SLO

PEDO

WN

1:20

ROOF

SLO

PEDO

WN

1:20

ROOF

SLO

PEDO

WN

1:20

ROOF

SLO

PEDO

WN

1:20

ROOF

SLO

PEDO

WN

1:20

ROOF

SLO

PEDO

WN

1:20

ROOF

SLO

PEDO

WN

1:20

F

F

ROOFSLOPE

ROOFSLOPE

500

OPEN TERRACE(@ +4.30m FROM

FFL APPROX.)

ROOF MONITOR FOR VENTILATION B

B

C

C

D

D

E

E

GG

TYPE SIZE

SCHEDULE OF OPENINGS

DISCRIPTION

5000 X 5000RS MECHANICALLY GEARED GI ROLLING SHUTTER

1200 X 2200ED SINGLE LEAF HMPS DOOR WITH PANIC BAR

D1

2000 X 2200D2 DOUBLE LEAF ALUMINIUM DOOR

1200 X 2200D3 / D3T SINGLE LEAF ALUMINIUM / PVC DOOR

800 X 2000D6 SINGLE LEAF PVC DOOR

2500 X 2200SD1 DOUBLE LEAF TOUGHENED GLASS DOOR WITHFLOOR SPRINGS

1500 X 1200W1 3 TRACK ALUMINIUM SLIDING WINDOWWITH FLY NET

1000 X 2200D4 / D4T SINGLE LEAF ALUMINIUM / PVC DOOR

900 X 2200D5 SINGLE LEAF HMPS DOOR

1500 X 2200 SINGLE LEAF HMPS DOOR

DRAFT COPYFOR TENDERINGFOR APPROVAL

Client:-

Project:-

Particulars:-

FOR EXECUTION

KUVELKAR SALKAR ASSOCIATESCONSULTING ENGINEERS

INDIAN INSTITUTE OF TECHNOLOGY

OVERALL ARCHITECTURAL DRAWING

KHARAGPUR

PROPOSED DEEP AND SHALLOW WATER MANEUVERINGAND SEAKEEPING BASIN FACILITY FOR OCEAN

ENGINEERING AND NAVAL ARCHITECTURE DEPARTMENT

DRG.NO: IIT_OENA_CYC_KSA_DWG_GA_00_OVERALL ARCHITECTURAL DRAWING

FOR APPROVAL GM RS01.02.2100· INTERNAL FIRE STATIONS REVISED· AIR CURTAINS FOR MODEL MAKING AREA DELETED GM RS03.02.2101

SCHEDULE OF OPENINGS GM RS25.03.2102

Page 62

AutoCAD SHX Text
ROOF TURBO FAN (NON- POWERED) TYP.
AutoCAD SHX Text
00
AutoCAD SHX Text
01
AutoCAD SHX Text
02
AutoCAD SHX Text
03
AutoCAD SHX Text
04
AutoCAD SHX Text
05
AutoCAD SHX Text
06
AutoCAD SHX Text
07
AutoCAD SHX Text
08
AutoCAD SHX Text
09
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
21
AutoCAD SHX Text
22
AutoCAD SHX Text
23
AutoCAD SHX Text
24
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
A'
AutoCAD SHX Text
B'
AutoCAD SHX Text
C'
AutoCAD SHX Text
D'
AutoCAD SHX Text
21'
AutoCAD SHX Text
EXISTING SHIP EXISTING SHIP HYDRODYNAMICS LAB.
AutoCAD SHX Text
EXISTING OENA DEPARTMENT
AutoCAD SHX Text
RCC SLAB OVER ROOMS BELOW ON GROUND FLOOR
AutoCAD SHX Text
FALSE CEILING
AutoCAD SHX Text
RCC SLAB OVER ROOMS BELOW ON GROUND FLOOR
AutoCAD SHX Text
1.40 M. WIDE PASSAGE
AutoCAD SHX Text
CONTROL ROOM
AutoCAD SHX Text
0
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
9
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
21
AutoCAD SHX Text
22
AutoCAD SHX Text
23
AutoCAD SHX Text
24
AutoCAD SHX Text
25
AutoCAD SHX Text
26
AutoCAD SHX Text
27
AutoCAD SHX Text
28
AutoCAD SHX Text
29
AutoCAD SHX Text
30
AutoCAD SHX Text
31
AutoCAD SHX Text
32
AutoCAD SHX Text
33
AutoCAD SHX Text
34
AutoCAD SHX Text
35
AutoCAD SHX Text
36
AutoCAD SHX Text
37
AutoCAD SHX Text
38
AutoCAD SHX Text
39
AutoCAD SHX Text
40
AutoCAD SHX Text
41
AutoCAD SHX Text
42
AutoCAD SHX Text
43
AutoCAD SHX Text
44
AutoCAD SHX Text
45
AutoCAD SHX Text
46
AutoCAD SHX Text
47
AutoCAD SHX Text
48
AutoCAD SHX Text
49
AutoCAD SHX Text
50
AutoCAD SHX Text
-1
AutoCAD SHX Text
-2
AutoCAD SHX Text
-3
AutoCAD SHX Text
-4
AutoCAD SHX Text
PAINT & RESIN STORE
AutoCAD SHX Text
AREA EARMARKED FOR CARRIAGE FABRICATION AND ASSEMBLY
AutoCAD SHX Text
SHIP MODEL STORAGE AREA
AutoCAD SHX Text
MODEL RAW MAT. STORE
AutoCAD SHX Text
ELECTRICAL ROOM (2 HR. FIRE RATED)
AutoCAD SHX Text
UPS ROOM (2 HR. FIRE RATED)
AutoCAD SHX Text
EXISTING SHIP EXISTING SHIP HYDRODYNAMICS LAB.
AutoCAD SHX Text
DEEP AND SHALLOW WAVE BASIN
AutoCAD SHX Text
EXISTING COOLING TOWERS
AutoCAD SHX Text
LAUNCHING BAY
AutoCAD SHX Text
EXISTING WELL
AutoCAD SHX Text
CANTILEVER SLAB OUTLINE
AutoCAD SHX Text
800
AutoCAD SHX Text
00
AutoCAD SHX Text
01
AutoCAD SHX Text
02
AutoCAD SHX Text
03
AutoCAD SHX Text
04
AutoCAD SHX Text
05
AutoCAD SHX Text
06
AutoCAD SHX Text
07
AutoCAD SHX Text
08
AutoCAD SHX Text
09
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
21
AutoCAD SHX Text
22
AutoCAD SHX Text
23
AutoCAD SHX Text
24
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
A'
AutoCAD SHX Text
B'
AutoCAD SHX Text
C'
AutoCAD SHX Text
D'
AutoCAD SHX Text
21'
AutoCAD SHX Text
EXISTING OENA DEPARTMENT
AutoCAD SHX Text
SPACE FOR "WAVE ENERGY LAB"
AutoCAD SHX Text
MONORAIL TRACK
AutoCAD SHX Text
MONORAIL TRACK
AutoCAD SHX Text
4.37x6.24
AutoCAD SHX Text
+2.82x3.10 (varies)
AutoCAD SHX Text
4.37x6.24
AutoCAD SHX Text
3.00x3.05
AutoCAD SHX Text
3.00x3.03
AutoCAD SHX Text
26.89 x 6.24
AutoCAD SHX Text
6.00 x 6.24
AutoCAD SHX Text
6.12 x 6.24
AutoCAD SHX Text
5.77 x 6.24
AutoCAD SHX Text
3.14 x 4.46
AutoCAD SHX Text
2.40 x 1.80
AutoCAD SHX Text
3.14 x 6.24
AutoCAD SHX Text
7.93 x 6.24
AutoCAD SHX Text
38.07 x 6.24
AutoCAD SHX Text
DIESEL ENGINE PUMP
AutoCAD SHX Text
96 cu.m/hr
AutoCAD SHX Text
ELECTRICAL MAIN PUMP
AutoCAD SHX Text
96 cu.m/hr
AutoCAD SHX Text
JOCKEY PUMP
AutoCAD SHX Text
180LPM
AutoCAD SHX Text
JOCKEY PUMP
AutoCAD SHX Text
180LPM
AutoCAD SHX Text
WATER PUMPING PUMP-1
AutoCAD SHX Text
100 m3/Hr
AutoCAD SHX Text
WATER PUMPING PUMP-2
AutoCAD SHX Text
100 m3/Hr
AutoCAD SHX Text
200Ltr. PRIMING TANK
AutoCAD SHX Text
2.12x4.89
AutoCAD SHX Text
+3.94x1.46
AutoCAD SHX Text
(300x300)
AutoCAD SHX Text
SUMP
AutoCAD SHX Text
EOT CRANE GIRDER
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
F.G.L.
AutoCAD SHX Text
EXISTING OENA DEPARTMENT
AutoCAD SHX Text
F.G.L.
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
EXISTING SHIP HYDRODYNAMICS LAB.
AutoCAD SHX Text
F
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
SPACE FOR "WAVE ENERGY LAB"
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
EXISTING SHIP HYDRODYNAMICS LAB.
AutoCAD SHX Text
SHIP MODEL STORAGE AREA
AutoCAD SHX Text
F
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
F.G.L.
AutoCAD SHX Text
F.G.L.
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
EXISTING SHIP HYDRODYNAMICS LAB.
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
GUTTER
AutoCAD SHX Text
GUTTER
AutoCAD SHX Text
EXISTING SHIP HYDRODYNAMICS LAB.
AutoCAD SHX Text
F
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
EXISTING SHIP HYDRODYNAMICS LAB.
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
EXISTING SHIP HYDRODYNAMICS LAB.
AutoCAD SHX Text
F
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
F.G.L.
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
EXISTING SHIP HYDRODYNAMICS LAB.
AutoCAD SHX Text
F
AutoCAD SHX Text
EXISTING SHIP HYDRODYNAMICS LAB.
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
F.G.L.
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
EXISTING SHIP HYDRODYNAMICS LAB.
AutoCAD SHX Text
F.F.L.
AutoCAD SHX Text
F
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
F.G.L.
AutoCAD SHX Text
00
AutoCAD SHX Text
01
AutoCAD SHX Text
02
AutoCAD SHX Text
03
AutoCAD SHX Text
04
AutoCAD SHX Text
05
AutoCAD SHX Text
06
AutoCAD SHX Text
07
AutoCAD SHX Text
08
AutoCAD SHX Text
09
AutoCAD SHX Text
10
AutoCAD SHX Text
11
AutoCAD SHX Text
12
AutoCAD SHX Text
13
AutoCAD SHX Text
14
AutoCAD SHX Text
15
AutoCAD SHX Text
16
AutoCAD SHX Text
17
AutoCAD SHX Text
18
AutoCAD SHX Text
19
AutoCAD SHX Text
20
AutoCAD SHX Text
21
AutoCAD SHX Text
22
AutoCAD SHX Text
23
AutoCAD SHX Text
24
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
A'
AutoCAD SHX Text
B'
AutoCAD SHX Text
C'
AutoCAD SHX Text
D'
AutoCAD SHX Text
21'
AutoCAD SHX Text
ROOF TURBO FAN (NON-POWERED) TYP.
AutoCAD SHX Text
Notes:-
AutoCAD SHX Text
Construction ref. Drawing:
AutoCAD SHX Text
Engg. ref. Drawing:
AutoCAD SHX Text
Legend:
AutoCAD SHX Text
Holds:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
DRN
AutoCAD SHX Text
CHK
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
REV.
AutoCAD SHX Text
1:200
AutoCAD SHX Text
A0+
AutoCAD SHX Text
-
AutoCAD SHX Text
02
AutoCAD SHX Text
A-2 RAMAKANT APTS.
AutoCAD SHX Text
OPP. PHARMACY COLLEGE
AutoCAD SHX Text
TEL. +91 832 2227527
AutoCAD SHX Text
ST. INEZ PANAJI GOA
AutoCAD SHX Text
Website: www.ksa-india.com
AutoCAD SHX Text
%%UHEAD OFFICE
AutoCAD SHX Text
4G, RUSHABH CHAMBERS,
AutoCAD SHX Text
MAKWANA ROAD,
AutoCAD SHX Text
MUMBAI 400 059
AutoCAD SHX Text
MAROL, ANDHERI (E)
AutoCAD SHX Text
%%UBRANCH OFFICE
AutoCAD SHX Text
ALL DIMENSIONS ARE IN mm & LEVELS IN m
AutoCAD SHX Text
- EXHAUST FAN

DRAFT COPYFOR TENDERINGFOR APPROVAL

Client:-

Project:-

Particulars:-

FOR EXECUTION

BASIN & STORAGE TANK LAYOUTS

KUVELKAR SALKAR ASSOCIATESCONSULTING ENGINEERS

INDIAN INSTITUTE OF TECHNOLOGYKHARAGPUR

PROPOSED DEEP AND SHALLOW WATER MANEUVERINGAND SEAKEEPING BASIN FACILITY FOR OCEAN

ENGINEERING AND NAVAL ARCHITECTURE DEPARTMENT

DRG.NO: IIT_OENA_CYC_KSA_DWG_GA_06_BASIN & STORAGE TANK LAYOUTS

·

··

·

·

··

500

1600

050

050

0

30000 30000 3100031000

STORAGE TANK LAYOUT @ -6.800m LVL.

5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5400 5400 5400 5400 4600 44005600

5400

5300

OPENING1000 x 2100

OPENING1000 x 2100

OPENING1000 x 2100

SUMP

RCC COLUMN(TYP.)

INTERNAL RCCWALL (TYP.)

500112000

1600

050

050

0

DEEP & SHALLOW WAVE BASIN LAYOUT @ -2.800m LVL.

ACCESS WELLFOR STORAGE TANK

6750

2500

6750

UP

R=175T=280

STORE / UTILITYROOM

STORE / UTILITYROOM

ACCESS TOSTORAGE TANK

400

B

B

B

B

C

C

C

C

D

D

D

D

E E

E E

W/P SLOPE DOWN

TOWARDS SUMP

(TYP. FOR ALL

COMPARTMENTS)

SUMP SUMP SUMP

VOID

ACCESS TOSTORAGE TANK

9200

2000 400

2.0m

WID

EC

OR

RID

OR

VOID

121200500

SERVICE DUCTFOR PIPING

VOID VOIDSERVICE DUCT

FOR PIPING

VOID

SERVICE DUCTFOR PIPING

SERVICE DUCTFOR PIPING

VOID

SERVICE DUCTFOR PIPING

VOID VOIDSERVICE DUCT

FOR PIPING

VOID

SERVICE DUCTFOR PIPING

SERVICE DUCTFOR PIPING

VOID

SUMP SUMP SUMP SUMP

SUMP AT THE BOTTOM OF SERVICEDUCT FOR DRAINAGE PURPOSE

(TYP. FOR ALL DUCTS)

SUMP SUMP SUMP SUMP

VOID

Ø 100 PVC VENT PIPE WITH VENT COWL(ONE FOR EACH COMPARTMENT OF STORAGE TANK)

Page 63

AutoCAD SHX Text
Notes:-
AutoCAD SHX Text
Construction ref. Drawing:
AutoCAD SHX Text
Engg. ref. Drawing:
AutoCAD SHX Text
Legend:
AutoCAD SHX Text
Holds:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
DRN
AutoCAD SHX Text
CHK
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
REV.
AutoCAD SHX Text
20.10.20
AutoCAD SHX Text
00
AutoCAD SHX Text
N.T.S
AutoCAD SHX Text
A0+
AutoCAD SHX Text
-
AutoCAD SHX Text
05
AutoCAD SHX Text
GM
AutoCAD SHX Text
RS
AutoCAD SHX Text
A-2 RAMAKANT APTS.
AutoCAD SHX Text
OPP. PHARMACY COLLEGE
AutoCAD SHX Text
TEL. +91 832 2227527
AutoCAD SHX Text
ST. INEZ PANAJI GOA
AutoCAD SHX Text
Website: www.ksa-india.com
AutoCAD SHX Text
%%UHEAD OFFICE
AutoCAD SHX Text
4G, RUSHABH CHAMBERS,
AutoCAD SHX Text
MAKWANA ROAD,
AutoCAD SHX Text
MUMBAI 400 059
AutoCAD SHX Text
MAROL, ANDHERI (E)
AutoCAD SHX Text
%%UBRANCH OFFICE
AutoCAD SHX Text
FOR APPROVAL
AutoCAD SHX Text
ALL DIMENSIONS ARE IN mm.
AutoCAD SHX Text
01.11.20
AutoCAD SHX Text
01
AutoCAD SHX Text
GM
AutoCAD SHX Text
RS
AutoCAD SHX Text
09.11.20
AutoCAD SHX Text
02
AutoCAD SHX Text
GM
AutoCAD SHX Text
RS
AutoCAD SHX Text
20.11.20
AutoCAD SHX Text
03
AutoCAD SHX Text
GM
AutoCAD SHX Text
RS
AutoCAD SHX Text
INTERNAL COMPARTMENT LAYOUT OF STORAGE TANK REVISED
AutoCAD SHX Text
LAYOUT OF UNDERGROUND STORE/UTILITY ROOMS REVISED & CORRIDOR ADDED
AutoCAD SHX Text
SERVICE DUCT LOCATIONS SHIFTED 2 MORE SERVICE DUCTS ADDED VENT PIPES ADDED FOR STORAGE TANK ACCESS VOIDS IN STORE/UTILITY ROOMS SHIFTED
AutoCAD SHX Text
15.12.20
AutoCAD SHX Text
04
AutoCAD SHX Text
GM
AutoCAD SHX Text
RS
AutoCAD SHX Text
ACCESS VOIDS IN STORE/UTILITY ROOMS SHIFTED BY 400mm TOWARDS EAST SUMP ADDED AT THE BOTTOM OF SERVICE DUCTS ACCESS WELL FOR STORAGE TANK AT SOUTH WEST CORNER OF BASIN REVISED
AutoCAD SHX Text
24.02.21
AutoCAD SHX Text
05
AutoCAD SHX Text
GM
AutoCAD SHX Text
RS
AutoCAD SHX Text
DRAWING UPDATED AS PER REVISED ARCH DRAWING
AutoCAD SHX Text
PROPOSED BUILDING OUTLINE
AutoCAD SHX Text
PROPOSED BUILDING OUTLINE
AutoCAD SHX Text
LAUNCHING BAY

DRAFT COPYFOR TENDERINGFOR APPROVAL

Client:-

Project:-

Particulars:-

FOR EXECUTION

BASIN & STORAGE TANK SECTIONS

KUVELKAR SALKAR ASSOCIATESCONSULTING ENGINEERS

INDIAN INSTITUTE OF TECHNOLOGYKHARAGPUR

PROPOSED DEEP AND SHALLOW WATER MANEUVERINGAND SEAKEEPING BASIN FACILITY FOR OCEAN

ENGINEERING AND NAVAL ARCHITECTURE DEPARTMENT

DRG.NO: IIT_OENA_CYC_KSA_DWG_GA_07_BASIN & STORAGE TANK SECTIONS

SECTION B-B

(I/I OF RCC WALLS)

W/P PLASTER +SUITABLE PAINT

MAX. WATER LVL.

MIN. WATER LVL.

100 THK. PCC

200 THK. SOLING

COBA W/P(IN SLOPE) SLOPE 1:100

OPENING ININTERNALRCC WALL RC

C CO

LUMN

RCC

COLU

MN

MAX. WATER LVL.

PVC VENTCOWL

Ø 100 PVC VENT PIPEWITH VENT COWL(ONE FOR EACH

COMPARTMENT OFSTORAGE TANK)

SECTION C-C

(I/I OF RCC WALLS)

MAX. WATER LVL.

MIN. WATER LVL.

COBA W/P(IN SLOPE)

OPENING ININTERNALRCC WALL

RCC

COLU

MN

RCC

COLU

MN

MAX. WATER LVL.HEAVY DUTY

COVER

SERVICEDUCT FOR

PIPING

100 THK. PCC

200 THK. SOLING

LADDERSLOPE 1:100

W/P PLASTER +SUITABLE PAINT

SUMP

SUMP AT ONE CORNER AT THE BOTTOM OFSERVICE DUCT FOR DRAINAGE PURPOSE

(TYP. FOR ALL DUCTS)

COBA W/P(IN SLOPE)

MIN. WATER LVL.

MAX. WATER LVL.

(I/I OF RCC WALLS)

LAUNCHINGBAY

SLOPE 1:100

STORE / UTILITYROOM

SECTION D-D

(I/I OF RCC WALLS)

MAX. WATER LVL.

100 THK. PCC

200 THK. SOLING

RCC

COLU

MN

RCC

COLU

MN

STORE / UTILITYROOM

1.10m HT.RAILING (TYP.)

INTERNAL RCCWALL (TYP.)

SECTION E-E

112000 (I/I OF RCC WALLS FOR UPPER BASIN)

100 THK. PCC200 THK. SOLING

COBA W/P(IN SLOPE)

RCC

COLU

MN

LAUNCHING BAY

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

MAX. WATER LVL.

MIN. WATER LVL.

MAX. WATER LVL.

MIN. WATER LVL.

MAX. WATER LVL.

MIN. WATER LVL.

MAX. WATER LVL.

WATER TIGHTGATE

STOPPER (TYP.)

CARRIAGE

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

RCC

COLU

MN

2.0m WIDECORRIDOR

MAX. WATER LVL. MAX. WATER LVL. MAX. WATER LVL.

Page 64

AutoCAD SHX Text
Notes:-
AutoCAD SHX Text
Construction ref. Drawing:
AutoCAD SHX Text
Engg. ref. Drawing:
AutoCAD SHX Text
Legend:
AutoCAD SHX Text
Holds:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV.
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
DRN
AutoCAD SHX Text
CHK
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
REV.
AutoCAD SHX Text
20.10.20
AutoCAD SHX Text
00
AutoCAD SHX Text
N.T.S
AutoCAD SHX Text
A2+
AutoCAD SHX Text
-
AutoCAD SHX Text
05
AutoCAD SHX Text
GM
AutoCAD SHX Text
RS
AutoCAD SHX Text
A-2 RAMAKANT APTS.
AutoCAD SHX Text
OPP. PHARMACY COLLEGE
AutoCAD SHX Text
TEL. +91 832 2227527
AutoCAD SHX Text
ST. INEZ PANAJI GOA
AutoCAD SHX Text
Website: www.ksa-india.com
AutoCAD SHX Text
%%UHEAD OFFICE
AutoCAD SHX Text
4G, RUSHABH CHAMBERS,
AutoCAD SHX Text
MAKWANA ROAD,
AutoCAD SHX Text
MUMBAI 400 059
AutoCAD SHX Text
MAROL, ANDHERI (E)
AutoCAD SHX Text
%%UBRANCH OFFICE
AutoCAD SHX Text
FOR APPROVAL
AutoCAD SHX Text
ALL DIMENSIONS ARE IN mm.
AutoCAD SHX Text
01.11.20
AutoCAD SHX Text
01
AutoCAD SHX Text
GM
AutoCAD SHX Text
RS
AutoCAD SHX Text
SECTIONS REVISED AS PER REVISED LAYOUTS
AutoCAD SHX Text
09.11.20
AutoCAD SHX Text
02
AutoCAD SHX Text
GM
AutoCAD SHX Text
RS
AutoCAD SHX Text
20.11.20
AutoCAD SHX Text
03
AutoCAD SHX Text
GM
AutoCAD SHX Text
RS
AutoCAD SHX Text
15.12.20
AutoCAD SHX Text
04
AutoCAD SHX Text
GM
AutoCAD SHX Text
RS
AutoCAD SHX Text
SECTIONS REVISED AS PER REVISED LAYOUTS
AutoCAD SHX Text
SECTIONS REVISED AS PER REVISED LAYOUTS
AutoCAD SHX Text
SECTIONS REVISED AS PER REVISED LAYOUTS
AutoCAD SHX Text
24.02.21
AutoCAD SHX Text
05
AutoCAD SHX Text
GM
AutoCAD SHX Text
RS
AutoCAD SHX Text
SECTIONS REVISED AS PER REVISED LAYOUTS
AutoCAD SHX Text
F.F.L. ±0.00m
AutoCAD SHX Text
G.L.
AutoCAD SHX Text
F.F.L. ±0.00m
AutoCAD SHX Text
F.F.L. ±0.00m
AutoCAD SHX Text
G.L.
AutoCAD SHX Text
F.F.L. ±0.00m
AutoCAD SHX Text
F.F.L. ±0.00m
AutoCAD SHX Text
F.F.L. ±0.00m
AutoCAD SHX Text
G.L.
AutoCAD SHX Text
F.F.L. ±0.00m
AutoCAD SHX Text
G.L.
AutoCAD SHX Text
F.F.L. ±0.00m

25A DPRCCB30mA

ELDB18WAY, TPN , DBLOCATION-ELECTRICAL PANEL ROOM GROUND FLOORCONNECTED LOAD:- 1.55KW

10ASP

MCB

R1 R2 R3 R4

R

25A, FPMCB

Y1 Y2 Y3 Y5

Y

B1 B2 B3 B6

B

25A DPRCCB30mA

25A DPRCCB30mA

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

R5

10ASP

MCB

R6

10ASP

MCB

Y6

10ASP

MCB

Y4

10ASP

MCB

B4

10ASP

MCB

B5

10ASP

MCB

RO

OM

NAM

E - A

IR L

OC

K ,P

OR

CH

TOTA

L W

ATT-

120

WTO

TAL

LOAD

- 40

W- 3

NO

S

RO

OM

NAM

E - S

EMIN

AR H

ALL

TOTA

L W

ATT-

80W

TOTA

L LO

AD -

40W

-02N

OS

TOTA

L W

ATT-

160W

RO

OM

NAM

E - C

LASS

RO

OM

-1&2

TOTA

L LO

AD-4

0W-0

4NO

S

RO

OM

NAM

E - G

ENTS

TO

ILET

,TO

ILET

FO

R P

HYS

ICAL

LY

TOTA

L W

ATT-

45W

TOTA

L LO

AD -1

5W-0

3NO

SLA

DIE

S TO

ILET

,LAD

IES

TOIL

ET

TOTA

L W

ATT-

106W

RO

OM

NAM

E - O

FFIC

E,PA

NTR

Y,R

ECEP

TIO

N,P

OR

CH

TO

TAL

LOAD

-31W

-01N

OS,

15W

-01N

OS,

20W

-3N

OS

RO

OM

NAM

E- L

ASER

CU

TTIN

G R

OO

M,3

D P

RIN

TIN

G R

OO

M

TOTA

L W

ATT-

160

WTO

TAL

LOAD

-40W

-4N

OS

TOTA

L W

ATT-

200W

TOTA

L LO

AD-4

0W-5

NO

SR

OO

M N

AME-

MO

NO

RAI

L TR

ACK

TOTA

L W

ATT-

80W

TOTA

L LO

AD-4

0W-2

NO

SR

OO

M N

AME-

MO

NO

RAI

L TR

ACK

TOTA

L W

ATT-

200W

TOTA

L LO

AD-4

0W-5

NO

SR

OO

M N

AME-

MO

NO

RAI

L TR

ACK

TOTA

L W

ATT-

160

W

RO

OM

NAM

E- P

AIN

T &

RES

IN S

TOR

E,M

OD

EL R

AW M

AT. S

TOR

E

TOTA

L LO

AD-4

0W-0

4NO

SIN

STR

UM

ENTA

TIO

N R

OO

M

TOTA

L W

ATT-

120W

RO

OM

NAM

E- E

LEC

TRIC

AL R

OO

M ,U

PS R

OO

M

TOTA

L LO

AD-4

0W-3

NO

S

TOTA

L W

ATT-

120W

TOTA

L LO

AD-4

0W-3

NO

SR

OO

M N

AME-

PAN

EL R

OO

M,P

UM

P R

OO

M

SPAR

E

SPAR

E

SPAR

E

SPAR

E

SPAR

E

SPAR

E

UPSDB18WAY, TPN , DBLOCATION-ELECTRICAL PANEL ROOM GROUND FLOORCONNECTED LOAD:- 7.8KW

16ASP

MCB

R1 R2 R3 R4

R

40A, FPMCB

Y1 Y2 Y3 Y4

Y

B1 B2 B3 B4

B

32A DPRCBO100mA

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

TOTA

L W

ATT-

600W

TOTA

L W

ATT-

300W

SPAR

E

32A DPRCBO100mA

32A DPRCBO100mA

ROOM

NAM

E-SE

MIN

AR H

ALL,

CLAS

S RO

OM-1

TOTA

L W

ATT-

300W

TOTA

L W

ATT-

300W

SPAR

E

ROOM

NAM

E-CL

ASS

ROOM

-2

ROOM

NAM

E-PA

NEL R

OOM

SPAR

E

ROOM

NAM

E-RE

CEPT

ION

TOTA

L W

ATT-

1500

W

ROOM

NAM

E-OF

FICE

TOTA

L LOA

D-16

A 1W

AY S

WIT

CH +

2Nos

. 6A

3 PIN

SOC

KET(

UPS)

-2NO

S

TOTA

L LOA

D-16

A 1W

AY S

WIT

CH +

2Nos

. 6A

3 PIN

SOC

KET(

UPS)

-1NO

S

TOTA

L LOA

D-16

A 1W

AY S

WIT

CH +

2Nos

. 6A

3 PIN

SOC

KET(

UPS)

-5NO

S

TOTA

L LOA

D-16

A 1W

AY S

WIT

CH +

2Nos

. 6A

3 PIN

SOC

KET(

UPS)

-1NO

S

TOTA

L LOA

D-16

A 1W

AY S

WIT

CH +

2Nos

. 6A

3 PIN

SOC

KET(

UPS)

-1NO

S

TOTA

L W

ATT-

1200

W

ROOM

NAM

E-FA

CULT

Y R0

0M-1

,2,3,4

TOTA

L LOA

D-16

A 1W

AY S

WIT

CH +

2Nos

. 6A

3 PIN

SOC

KET(

UPS)

-4NO

S

TOTA

L W

ATT-

1200

W

ROOM

NAM

E-CO

NFER

ENCE

ROO

MTO

TAL L

OAD-

16A

1WAY

SW

ITCH

+ 2N

os. 6

A 3 P

IN S

OCKE

T(UP

S)-4

NOS

TOTA

L W

ATT-

1800

W

ROOM

NAM

E-IC

HAIR

MAN

OFFI

CE,R

ESEA

RCH

ROOM

-2,IT

ROO

M

TOTA

L LOA

D-16

A 1W

AY S

WIT

CH +

2Nos

. 6A

3 PIN

SOC

KET(

UPS)

-6NO

S

ROOM

NAM

E-CO

NTRO

L ROO

M TO

TAL L

OAD-

16A

1WAY

SW

ITCH

+ 2N

os. 6

A 3 P

IN S

OCKE

T(UP

S)-2

NOS

TOTA

L W

ATT-

600W

ACDB16WAY, TPN , DBLOCATION-ELECTRICAL PANEL ROOM GROUND FLOORCONNECTED LOAD:- 34.8KW

40ASP

MCB

R1 R2 R3 R4

R

100A, FPMCB

Y1 Y2 Y3 Y4

Y

B1 B2 B3 B4

B

D1-3600W

D2-3600W

D7-2400W

D8-1800W

D3-3600WSPARE

D4-2400W

D9-1800WD10-2400W

SPARE D5-2400W

D6-2400W

D11-2400W

D12-2400WSPARE

ACDB26WAY, TPN , DBLOCATION-ELECTRICAL PANEL ROOM GROUND FLOORCONNECTED LOAD:- 42.6KW

R1 R2 R3 R4

R

100A, FPMCB

Y1 Y2 Y3 Y4

Y

B1 B2 B3 B4

B

D1-1800W D7-3600W

D8-2400W

D13-3600W D3-1800WSPARE

D4-1800W

D9-1800W SPARE D5-3600W D11-2400W

D12-2400WSPARE

D2-1800W D6-3600WD10-1800WD15-3600WD16-1200W

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

D13-1800WSPARE D12A-1800W

100A, SPMCB

D14-3600W

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

40ASP

MCB

100A, SPMCB

100A, SPMCB

100A, SPMCB

100A, SPMCB

100A, SPMCB

D17-1800W

20kVAUPS

BATTERY

40A,

FP,

ISO

LATO

R40

A, F

P,IS

OLA

TOR

40ATPNMCCB

25ATPNMCB

PANEL NAME :- MAIN UPS DBCONNECTED LOAD :13KWDEMAND LOAD :- 13KW

40ATPNMCB

40ATPNMCB

SPARE

25ATPNMCB

125ATPNMCCB

63ATPNMCB

PANEL NAME :- MAIN POWER DBCONNECTED LOAD :30KWDEMAND LOAD :- 30KW

63ATPNMCB

40ATPNMCB

63ATPNMCB

40ATPNMCB

SPARE SPARE

63ATPNMCB

63ATPNMCCB

32ATPNMCB

PANEL NAME :- MAIN LIGHTING DBCONNECTED LOAD :20.97KWDEMAND LOAD :- 20.97KW

32ATPNMCB

32ATPNMCB

32ATPNMCB

CONNECTED LOAD INkW

DESCRIPTION

AL BUSBAR.80A, 415V, 50Hz TPN

DEMAND LOAD IN kW

80A TP MCCB+NWITH T/M BASEDRELEASESO/C, S/C

F1

PANEL NAME :- FIRE-FIGHTINGPANEL CONNECTED LOAD :- 41KWDEMAND LOAD :- 3.28KW

MAIN PUMP

37KW

JOCKEY PUMP

29.6KW

SPARE SPARE

-

-

-

-

4KW

3.2KW

F2

DOL

C1

C2

C3

ON OFF TRIP

START STOP

SELECTORSWITCH

E.STOP

M

63A TP MCCB+NWITH T/MBASED RELEASES25kA O/C, S/C

F3

DOL

C1

C2

C3

ON OFF TRIP

START STOP

SELECTORSWITCH

E.STOP

M

16A TP MCCB+NWITH T/MBASED RELEASES25kA O/C, S/C

F4

DOL

C1

C2

C3

ON OFF TRIP

START STOP

SELECTORSWITCH

E.STOP

M

63A TP MCCB+NWITH T/MBASED RELEASES25kA O/C, S/C

F5

DOL

C1

C2

C3

ON OFF TRIP

START STOP

SELECTORSWITCH

E.STOP

M

40A TP MCCB+NWITH T/MBASED RELEASES25kA O/C, S/C

CONNECTED LOAD INkW

DESCRIPTION

AL BUSBAR80A, 415V, 50Hz TPN

DEMAND LOAD IN kW

80A TP MCCB+NWITH T/M BASEDRELEASESO/C, S/C

PANEL NAME :-WATER PANELCONNECTED LOAD :- 44KWDEMAND LOAD :- 28.16KW

BOOSTER PUMP

22KW

STANDBY PUMP

17.6KW

SPARE SPARE

-

-

-

-

22KW

F2

DOL

C1

C2

C3

ON OFF TRIP

START STOP

SELECTORSWITCH

E.STOP

M

40A TP MCCB+NWITH T/MBASED RELEASES25kA O/C, S/C

F3

DOL

C1

C2

C3

ON OFF TRIP

START STOP

SELECTORSWITCH

E.STOP

M

40A TP MCCB+NWITH T/MBASED RELEASES25kA O/C, S/C

F4

DOL

C1

C2

C3

ON OFF TRIP

START STOP

SELECTORSWITCH

E.STOP

M

40A TP MCCB+NWITH T/MBASED RELEASES25kA O/C, S/C

F5

DOL

C1

C2

C3

ON OFF TRIP

START STOP

SELECTORSWITCH

E.STOP

M

40A TP MCCB+NWITH T/MBASED RELEASES25kA O/C, S/C

17.6KW

BOREWELL PUMP

22KW

17.6KW

F6

DOL

C1

C2

C3

ON OFF TRIP

START STOP

SELECTORSWITCH

E.STOP

M

40A TP MCCB+NWITH T/MBASED RELEASES25kA O/C, S/C

F1

CONNECTED LOAD INkW

LOCATION

DESCRIPTION

-

AL BUSBAR,FOR 25kA 1SEC.800A, 415V, 50Hz TPN

DEMAND LOAD IN kW

F2

3

6A, TP MCB 0-500V

CT1:800/5A15VA,CL.1

LM0-800A

A

6A, TP MCB R Y B

V

800A TP MCCB+NWITH M/P BASEDRELEASES25kA O/C, S/C

** # 3.5C x 300 SQ.MM,AL, Armoured XLPE ,CABLE

100ATPMCCB+N

F1F3 F4 F5 F6 F7 F9 F10

630ATP MCCB+N

PANEL NAME :- MAIN PCC PANELCONNECTED LOAD :- 558KWDEMAND LOAD :- 314KW

FIRE FIGHTING PANEL

40ATPMCCB+N

125ATPMCCB+N

63ATPMCCB+N

80ATPMCCB+N

80ATPMCCB+N

3CT1:800/5A15VA,CL.1

TO APFC

40ATPMCCB+N

41KW

WATER PUMPING SYSTEM

44KW

MLDB MPDB

30KW20.97KW

3.28KW 28.16KW

UPS ACDB-1

F11

32ATPMCCB+N

COMPRESSOR

F12

63ATPMCCB+N

PASSENGER ELEVATOR

F13

400ATPMCCB+N

OVERHEAD CRANE (5 TONNE)

F14

100ATPMCCB+N

CARRIAGE

F15

40ATPMCCB+N

WAVE MAKER

------

-

-34.8KW

20KW

13KW

240kVAR APFC

24KW

9.60KW

7.5KW

5.28KW

32KW

22.4KW

180KW

100.8KW

50KW

28KW

WATER FILTRATION SYSTEM

-

15KW

8.4KW

F16

100ATPMCCB+N

F17

63ATPMCCB+N

F18

40ATPMCCB+N

F19

40ATPMCCB+N

SPARE

-

-

-

-

-

-

-

-

-

-

-

-

-----

42.6KW

24KW

-

F8

100ATPMCCB+N

SPARE SPARE SPARE ACDB-2

13KW30KW

11KV,400A VCB 11KV,400A

VCB

11KV,from Substation no .3

11KV,to Nalanda Substation

11KV,400A VCB

Bus PT

11KV,400A VCB

TR-11000kVA,11KV/415VTransformer

TR-2500kVA,11KV/415VTransformer

1600A,ACB 800A,ACB

1000A,ACB

800A,ACB

800A,ACB

800A,ACB

Nalanda Feeder Box(For alternatepower supply)

Spare Spare

Bus Coupler

Proposed

Existing

Existing

25A DPRCCB30mA

SLDB28WAY, TPN , DBLOCATION-ELECTRICAL PANEL ROOM GROUND FLOOR CONNECTED LOAD:-3.71KW

10ASP

MCB

R1 R2 R3 R4

R

32A, FPMCB

Y1 Y2 Y3 Y4

Y

B1 B2 B3 B4

B

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

Y5 Y6 B5 B6

TOTA

L W

ATT-

155W

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

R5

10ASP

MCB

R6

10ASP

MCB

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L LO

AD -

31W

- 5N

OS

RO

OM

NAM

E - L

AB T

ECH

NIC

IAN

S,PA

SSAG

E

TOTA

L W

ATT-

380

WTO

TAL

LOAD

- 40

W- 8

NO

S,60

W-1

NO

S

RO

OM

NAM

E - I

NC

UBA

TIO

N C

ENTE

R

SPAR

E

TOTA

L W

ATT-

680W

RO

OM

NAM

E - F

ACU

LTY

R00

M-1

,2,3

,4,1

.30m

WID

E PA

SSAG

E TO

TAL

LOAD

- 40

W- 1

1NO

S,60

W-4

NO

S

RO

OM

NAM

E - R

ESEA

RC

H S

CH

OLA

R R

OO

M-2

TOTA

L W

ATT-

320

W

TOTA

L W

ATT-

220W

RO

OM

NAM

E -T

EA R

OO

M ,I

T / S

ERVE

R R

OO

M

RO

OM

NAM

E -,P

ASSA

GE

TOTA

L W

ATT-

120

W

SPAR

E

SPAR

E

RO

OM

NAM

E - C

ON

FER

ENC

E R

OO

M

TOTA

L W

ATT-

368

WTO

TAL

LOAD

- 31

W- 8

NO

S,40

W-3

NO

S

RO

OM

NAM

E -L

IBR

ARY/

MEE

TIN

G

TOTA

L W

ATT-

124

WTO

TAL

LOAD

- 31

W- 4

NO

S

TOTA

L W

ATT-

120W

RO

OM

NAM

E - C

ON

TRO

L R

OO

M

TOTA

L LO

AD -

40W

- 3N

OS

SPAR

E

SPAR

E

TOTA

L W

ATT-

500

WTO

TAL

LOAD

- 40

W- 8

NO

S,60

W-3

NO

S

SPAR

E

TOTA

L LO

AD -

40W

- 05N

OS,

60W

-2N

OS

TOTA

L LO

AD -

40W

- 04N

OS,

60W

-1N

OS

TOTA

L LO

AD -

40W

- 03N

OS

RO

OM

NAM

E - G

ENTS

TO

ILET

,TO

ILET

FO

R P

HYS

ICAL

LY

TOTA

L W

ATT-

445

WTO

TAL

LOAD

-15W

-11N

OS,

40W

-01N

OS,

60W

-4N

OS

SER

VIC

E D

UC

T,LA

DIE

S TO

ILET

,LAD

IES

TOIL

ET

10ASP

MCB

25A DPRCCB30mA

25A DPRCCB30mA

25A DPRCCB30mA

SLDB112WAY, TPN , DBLOCATION-ELECTRICAL PANEL ROOM GROUND FLOORCONNECTED LOAD:-7.93KW

10ASP

MCB

R1 R2 R3 R4

R

4C x 2.5Sqmm, CU.Arm., XLPE , Cable

32A, FPMCB

Y1 Y2 Y3 Y4

Y

B1 B2 B3 B4

B

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

16ASP

MCB

10ASP

MCB

R7

10ASP

MCB

R8

10ASP

MCB

Y5 Y6 B5 B6

RO

OM

NAM

E- C

LASS

RO

OM

-2

TOTA

L W

ATT-

400W

TOTA

L LO

AD- 4

0W -0

4NO

S,60

W-4

NO

S

RO

OM

NAM

E- R

ECEP

TIO

N,P

OR

CH

,STA

IRS

TOTA

L W

ATT-

380W

TOTA

L LO

AD-2

0W-0

7NO

S,40

W-3

NO

S,60

W-2

NO

S

TOTA

L W

ATT-

200W

TOTA

L LO

AD-4

0W-5

NO

S

RO

OM

NAM

E - S

EMIN

AR H

ALL

TOTA

L W

ATT-

880

WTO

TAL

LOAD

- 40

W-1

3NO

S

RO

OM

NAM

E- L

ASER

CU

TTIN

G R

OO

M

TOTA

L W

ATT-

400W

TOTA

L LO

AD-4

0W-7

NO

S,60

W-2

NO

S

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

RO

OM

NAM

E - G

ENTS

TO

ILET

,TO

ILET

FO

R P

HYS

ICAL

LY

TOTA

L W

ATT-

565

WTO

TAL

LOAD

-15W

-11N

OS,

40W

-04N

OS,

60W

-4N

OS

RO

OM

NAM

E- M

ON

OR

AIL

TRAC

K

R5

10ASP

MCB

R6

10ASP

MCB

Y7

10ASP

MCB

Y9

SPAR

E

10ASP

MCB

B7 B8

SPAR

E

10ASP

MCB

10ASP

MCB

TOTA

L W

ATT-

200

W

TOTA

L W

ATT-

200

W

RO

OM

NAM

E- P

AIN

T &

RES

IN S

TOR

E,M

OD

EL R

AW M

AT. S

TOR

E

RO

OM

NAM

E- U

PS R

OO

M

TOTA

L LO

AD-4

0W-0

2NO

S,60

W-2

NO

S

TOTA

L LO

AD-4

0W-5

NO

S

TOTA

L W

ATT-

280W

RO

OM

NAM

E - I

NST

RU

MEN

TATI

ON

RO

OM

TO

TAL

LOAD

-40W

-07N

OS

TOTA

L W

ATT-

260W

RO

OM

NAM

E- E

LEC

TRIC

AL R

OO

M

TOTA

L LO

AD-4

0W-5

NO

S,60

W-1

NO

S

TOTA

L W

ATT-

240W

TOTA

L LO

AD-4

0W-6

NO

SR

OO

M N

AME-

MO

NO

RAI

L TR

ACK

TOTA

L W

ATT-

200W

TOTA

L LO

AD-4

0W-5

NO

SR

OO

M N

AME-

MO

NO

RAI

L TR

ACK

R9

10ASP

MCB

R10

10ASP

MCB

SPAR

E

SPAR

E

SER

VIC

E D

UC

T,LA

DIE

S TO

ILET

,LAD

IES

TOIL

ET

TOTA

L W

ATT

-160

WTO

TAL

LOAD

-40W

-4N

OS

RO

OM

NAM

E- M

ON

OR

AIL

TRAC

K

TOTA

L W

ATT

- 200

WTO

TAL

LOAD

-40W

-5N

OS

RO

OM

NAM

E- M

ON

OR

AIL

TRAC

K

TOTA

L W

ATT

- 160

WTO

TAL

LOAD

-40W

-4N

OS

RO

OM

NAM

E- M

ON

OR

AIL

TRAC

K

Y8

10ASP

MCB

TOTA

L W

ATT-

260W

RO

OM

NAM

E - P

ANEL

RO

OM

TO

TAL

LOAD

-40W

-05N

OS,

60W

-1N

OS

Y10

SPAR

E

10ASP

MCB

TOTA

L W

ATT-

520W

RO

OM

NAM

E - C

LASS

RO

OM

-1,P

ASSA

GE

TOTA

L LO

AD-4

0W-0

7NO

S,60

W-4

NO

S

TOTA

L W

ATT-

385W

RO

OM

NAM

E - O

FFIC

E,PA

NTR

Y,ST

AIR

S

TOTA

L LO

AD-3

1W-0

5NO

S,15

W-0

2NO

S,40

W-2

NO

S,60

W-2

NO

S

TOTA

L W

ATT-

680W

RO

OM

NAM

E - 3

D P

RIN

TIN

G R

OO

M ,P

ASSA

GE

TOTA

L LO

AD-4

0W-1

4NO

S,60

W-2

NO

S

TOTA

L W

ATT

-160

WTO

TAL

LOAD

-40W

-4N

OS

RO

OM

NAM

E- M

ON

OR

AIL

TRAC

K

TOTA

L W

ATT

- 200

WTO

TAL

LOAD

-40W

-5N

OS

RO

OM

NAM

E- M

ON

OR

AIL

TRAC

K

TOTA

L W

ATT

- 160

WTO

TAL

LOAD

-40W

-4N

OS

RO

OM

NAM

E- M

ON

OR

AIL

TRAC

K

TOTA

L W

ATT-

520W

RO

OM

NAM

E- P

UM

P R

OO

M

TOTA

L LO

AD-4

0W-1

3NO

S

B9

10ASP

MCB

SPAR

E

B10

10ASP

MCB

RO

OM

NAM

E - S

EMIN

AR H

ALL

TOTA

L LO

AD -

40W

-13N

OS,

60W

-6N

OS

25A DPRCCB30mA

25A DPRCCB30mA

20.97KW

25A DPRCCB30mA

ELDB28WAY, TPN , DBLOCATION-ELECTRICAL PANEL ROOM GROUND FLOORCONNECTED LOAD:- 3.38KW

10ASP

MCB

R1 R2 R3 R4

R

4C x 2.5Sqmm, CU.Arm., XLPE , Cable

25A, FPMCB

Y1 Y2 Y3 Y5

Y

B1 B2 B3 B6

B

25A DPRCCB30mA

25A DPRCCB30mA

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

R5

10ASP

MCB

R6

10ASP

MCB

Y6

10ASP

MCB

Y4

10ASP

MCB

B4

10ASP

MCB

B5

10ASP

MCB

RO

OM

NAM

E - F

ACU

LTY

R00

M 3

& 4

,PAS

SAD

E

TOTA

L W

ATT-

120

WTO

TAL

LOAD

- 40

W-0

3NO

S

TOTA

L W

ATT-

62W

RO

OM

NAM

E - C

ON

FER

ENC

E R

OO

M,C

HAI

RM

AN O

FFIC

E

TOTA

L LO

AD-3

1W-0

2NO

S

RO

OM

NAM

E - G

ENTS

TO

ILET

,TO

ILET

FO

R P

HYS

ICAL

LY

TOTA

L W

ATT-

125W

TOTA

L LO

AD -1

5W-0

3NO

S,40

W-2

NO

SLA

DIE

S TO

ILET

,LAD

IES

TOIL

ET,R

ESEA

RC

H S

CH

OLA

R R

OO

M-2

TOTA

L W

ATT-

120W

RO

OM

NAM

E - L

AB T

ECH

NIC

IAN

S ,T

EA R

OO

M ,I

T R

OO

MTO

TAL

LOAD

-40W

-3N

OS

RO

OM

NAM

E- L

IBR

ARY/

MEE

TIN

G,IN

CU

BATI

ON

CEN

TRE

,PAS

SAG

E

TOTA

L W

ATT-

231

WTO

TAL

LOAD

- 31W

-1N

OS,

40W

-5N

OS

SPAR

E

SPAR

E

SPAR

E

SPAR

E

SPAR

E

RO

OM

NAM

E - E

NTR

ANC

E PA

SSAG

E,FA

CU

LTY

R00

M-1

& 2

TOTA

L W

ATT-

160

WTO

TAL

LOAD

- 40

W- 4

NO

S

CO

NTR

OL

RO

OM

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L W

ATT-

480

WTO

TAL

LOAD

- 12

0W- 4

NO

S

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L W

ATT-

480

WTO

TAL

LOAD

- 12

0W- 4

NO

S

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L W

ATT-

480

WTO

TAL

LOAD

- 12

0W- 4

NO

S

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L W

ATT-

480

WTO

TAL

LOAD

- 12

0W- 4

NO

S

RO

OM

NAM

E -A

REA

EAR

MAR

KED

FO

R C

ARR

IAG

E

TOTA

L W

ATT-

480

WTO

TAL

LOAD

- 12

0W- 4

NO

S

SPAR

E

RO

OM

NAM

E -S

HIP

MO

DEL

STO

RAG

E AR

EA

TOTA

L W

ATT-

160

WTO

TAL

LOAD

- 40

W- 4

NO

S

25A DPRCCB30mA

SLDB312WAY, TPN , DBLOCATION-ELECTRICAL PANEL ROOM GROUND FLOORCONNECTED LOAD:-7.32KW

10ASP

MCB

R1 R2 R3 R4

R

32A, FPMCB

Y1 Y2 Y3 Y4

Y

B1 B2 B3 B4

B

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L W

ATT-

240

W

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

16ASP

MCB

10ASP

MCB

TOTA

L LO

AD -

120W

- 2N

OS

R7

10ASP

MCB

R8

10ASP

MCB

Y5 Y6 B5 B6

TOTA

L W

ATT-

480W

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

R5

10ASP

MCB

R6

10ASP

MCB

Y7

10ASP

MCB

B7 B8

10ASP

MCB

10ASP

MCB

Y8

10ASP

MCB

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L LO

AD -

120W

- 4N

OS

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L W

ATT-

240

WTO

TAL

LOAD

- 12

0W- 2

NO

S

TOTA

L W

ATT-

480W

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L LO

AD -

120W

- 4N

OS

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L W

ATT-

240

WTO

TAL

LOAD

- 12

0W- 2

NO

S

TOTA

L W

ATT-

480W

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L LO

AD -

120W

- 4N

OS

RO

OM

NAM

E -S

HIP

MO

DEL

STO

RAG

E AR

EA

TOTA

L W

ATT-

400

WTO

TAL

LOAD

- 40

W- 1

0NO

S

SPAR

E

TOTA

L W

ATT-

480W

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L LO

AD -

120W

- 4N

OS

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L W

ATT-

240

WTO

TAL

LOAD

- 12

0W- 2

NO

S

TOTA

L W

ATT-

480W

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L LO

AD -

120W

- 4N

OS

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L W

ATT-

240

WTO

TAL

LOAD

- 12

0W- 2

NO

S

TOTA

L W

ATT-

480W

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L LO

AD -

120W

- 4N

OS

TOTA

L W

ATT-

240W

RO

OM

NAM

E -S

HIP

MO

DEL

STO

RAG

E AR

EA

TOTA

L LO

AD -

120W

- 2N

OS

SPAR

E

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L W

ATT-

240

WTO

TAL

LOAD

- 12

0W- 2

NO

S

TOTA

L W

ATT-

480W

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L LO

AD -

120W

- 4N

OS

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L W

ATT-

240

WTO

TAL

LOAD

- 12

0W- 2

NO

S

TOTA

L W

ATT-

480W

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L LO

AD -

120W

- 4N

OS

RO

OM

NAM

E -D

EEP

AND

SH

ALLO

W W

AVE

BASI

N

TOTA

L W

ATT-

240

WTO

TAL

LOAD

- 12

0W- 2

NO

S

RO

OM

NAM

E -A

REA

EAR

MAR

KED

FO

R C

ARR

IAG

E

TOTA

L W

ATT-

600

WTO

TAL

LOAD

- 12

0W- 5

NO

S

SPAR

E

SPAR

E

25A DPRCCB30mA

25A DPRCCB30mA

TOTA

L W

ATT-

320W

RO

OM

NAM

E -S

HIP

MO

DEL

STO

RAG

E AR

EA

TOTA

L LO

AD -

40W

- 8N

OS

SPARE

32ATPNMCB

SPARE

32ATPNMCB

25A DPRCCB30mA

SLDB46WAY, TPN , DBLOCATION-ELECTRICAL PANEL ROOM GROUND FLOORCONNECTED LOAD:-2.01KW

10ASP

MCB

R1 R2 R3 R4

R

32A, FPMCB

Y1 Y2 Y3 Y4

Y

B1 B2 B3 B4

B

RO

OM

NAM

E -U

PPER

BAS

IN U

ND

ER W

ATER

LIG

HT

TOTA

L W

ATT-

180

W

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

16ASP

MCB

10ASP

MCB

TOTA

L LO

AD -

18W

- 10

NO

S

Y5 Y6 B5 B6

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

10ASP

MCB

R5

10ASP

MCB

R6

10ASP

MCB

SPAR

E

SPAR

E

SPAR

E

25A DPRCCB30mA

25A DPRCCB30mA

SPAR

E

SPAR

E

SPAR

E

RO

OM

NAM

E -U

PPER

BAS

IN U

ND

ER W

ATER

LIG

HT

TOTA

L W

ATT-

162

WTO

TAL

LOAD

- 18

W -

09N

OS

RO

OM

NAM

E -U

PPER

BAS

IN U

ND

ER W

ATER

LIG

HT

TOTA

L W

ATT-

162

WTO

TAL

LOAD

- 18

W -

09N

OS

RO

OM

NAM

E -U

PPER

BAS

IN U

ND

ER W

ATER

LIG

HT

TOTA

L W

ATT-

180

WTO

TAL

LOAD

- 18

W -

10N

OS

RO

OM

NAM

E -U

PPER

BAS

IN U

ND

ER W

ATER

LIG

HT

TOTA

L W

ATT-

162

WTO

TAL

LOAD

- 18

W -

09N

OS

RO

OM

NAM

E -U

PPER

BAS

IN U

ND

ER W

ATER

LIG

HT

TOTA

L W

ATT-

162

WTO

TAL

LOAD

- 18

W -

09N

OS

RO

OM

NAM

E -U

PPER

BAS

IN U

ND

ER W

ATER

LIG

HT

TOTA

L W

ATT-

180

WTO

TAL

LOAD

- 18

W -

10N

OS

RO

OM

NAM

E -U

PPER

BAS

IN U

ND

ER W

ATER

LIG

HT

TOTA

L W

ATT-

180

WTO

TAL

LOAD

- 18

W -

10N

OS

RO

OM

NAM

E -U

PPER

BAS

IN U

ND

ER W

ATER

LIG

HT

TOTA

L W

ATT-

162

WTO

TAL

LOAD

- 18

W -

09N

OS

RO

OM

NAM

E -U

PPER

BAS

IN U

ND

ER W

ATER

LIG

HT

TOTA

L W

ATT-

162

WTO

TAL

LOAD

- 18

W -

09N

OS

RO

OM

NAM

E -U

PPER

BAS

IN U

ND

ER W

ATER

LIG

HT

TOTA

L W

ATT-

162

WTO

TAL

LOAD

- 18

W -

09N

OS

RO

OM

NAM

E -U

PPER

BAS

IN U

ND

ER W

ATER

LIG

HT

TOTA

L W

ATT-

162

WTO

TAL

LOAD

- 18

W -

09N

OS

RO

OM

NAM

E - A

IR L

OC

K ,P

OR

CH

,STA

IRS,

LIFT

TOTA

L W

ATT-

320

WTO

TAL

LOAD

- 40

W- 8

NO

S

RO

OM

NAM

E - E

NTR

ANC

E PA

SSAG

E,LI

FT

TOTA

L W

ATT-

280

WTO

TAL

LOAD

- 40

W- 7

NO

S

SPDB112WAY, TPN , DBLOCATION-ELECTRICAL PANEL ROOM GROUND FLOORCONNECTED LOAD:-15.36KW

16ASP

MCB

R1 R2 R3 R4

R

4C x 6Sqmm, CU.Arm., XLPE , Cable

63A, FPMCB

Y1 Y2 Y3 Y4

Y

B1 B2 B3 B4

B

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

TOTA

L W

ATT-

1100

W

TOTA

L LO

AD-1

6A 1

WAY

SW

ITCH

WIT

H 16

A, 6

PIN

SOCK

ET(R

AW).-

5NO

S

ROOM

NAM

E-GE

NTS

TOILE

T,SE

RVIC

E DU

CT

TOTA

L W

ATT-

420W

ROOM

NAM

E-PA

NTRY

,OFF

ICE

40A DPRCBO100mA

ROOM

NAM

E-AI

R LO

CK,D

RINK

ING

WAT

ER,P

ORCH

,LIF

T

TOTA

L LOA

D-AW

) -6A

3 PI

N MO

DULA

R SW

ITCH

SOC

KET-

3NOS

TOTA

L W

ATT-

400W

TOTA

L W

ATT-

400W

TOTA

L W

ATT-

420W

ROOM

NAM

E-PA

NTRY

,REC

EPTI

ON

TOTA

L W

ATT-

1000

W

ROOM

NAM

E-LA

DIES

TOI

LET

TOTA

L W

ATT-

500W

ROOM

NAM

E-CL

ASS

ROOM

-1 &

2

ROOM

NAM

E-OF

FICE

TOTA

L W

ATT-

300W

TOTA

L LO

AD-6

A 1W

AY S

WIT

CH W

ITH

6A, 3

PIN

SO

CKET

(RAW

)-3NO

S

ROOM

NAM

E-SE

MINA

R HA

LL

TOTA

L LOA

D-6A

3 PI

N MO

DULA

R SW

ITCH

SOC

KET-

4NOS

TOTA

L LOA

D-6A

1WAY

SW

ITCH

WIT

H 6A

, 3PI

N S

OCKE

T (R

AW)-

5NOS

6A 3

PIN

SOCK

ET-2

No

ROOM

NAM

E- R

ECEP

TION

TOTA

L W

ATT-

300W

R5 R6

16ASP

MCB

16ASP

MCB

ROOM

NAM

E-PA

INT

& RE

SIN

STOR

E,MO

DEL R

AW M

AT.S

TORE

TOTA

L W

ATT-

1000

WTO

TAL

LOAD

-20A

, 1PH

ASE

INDU

STRI

AL S

OCK

ET w

ith 2

0A S

PN M

CB-2

NOS

ROOM

NAM

E-3D

PRI

NTIN

G RO

OM,T

OILE

T

TOTA

L W

ATT-

2380

W

ROOM

NAM

E-EL

ECTR

ICAL

ROO

M,UP

S RO

OM

TOTA

L W

ATT-

900W

TOTA

L LO

AD-1

6A 1

WAY

SW

ITCH

WIT

H 16

A, 6

PIN

SOCK

ET(R

AW)-2

Nos

Y5

16ASP

MCB

ROOM

NAM

E - I

NSTR

UMEN

TATI

ON R

OOM

TOTA

L W

ATT-

2100

W

Y6

16ASP

MCB

B5

16ASP

MCB

B6

16ASP

MCB

TOTA

L LO

AD-2

0A, 1

PHAS

E IN

DUST

RIAL

SO

CKET

with

20A

SPN

MCB

-4No

s

20A,

1PH

ASE

INDU

STRI

AL S

OCK

ET w

ith 2

0A S

PN M

CB-1

Nos

6A 1

WAY

SW

ITC

H W

ITH

6A,

3PI

N S

OC

KET

(RAW

)-1N

OS

TOTA

L LOA

D-AW

) -6A

3 PI

N MO

DULA

R SW

ITCH

SOC

KET-

4NOS

ROOM

NAM

E-LA

SER

CUTT

ING

ROOM

TOTA

L W

ATT-

2060

W

TOTA

L LOA

D-AW

) - 20

A, 1P

HASE

INDU

STRI

AL S

OCKE

T wi

th 20

A SP

N MC

B-4 N

OS

6A 3

PIN

SOCK

ET -1

NOS.

R7

16ASP

MCB

ROOM

NAM

E-PA

NEL R

OOM,

PUMP

ROO

M

TOTA

L W

ATT-

800W

TOTA

L LOA

D-AW

) -6A

3 PI

N MO

DULA

R SW

ITCH

SOC

KET-

3NOS

20

A, 1

PHAS

E IN

DUST

RIAL

SO

CKET

with

20A

SPN

MCB

-1NO

S

TOTA

L LOA

D-6A

3 PI

N MO

DULA

R SW

ITCH

SOC

KET-

3NOS

6A

3 PI

N SO

CKET

-2No

16A

1WAY

SW

ITC

H W

ITH

16A

, 6PI

N S

OC

KET(

RAW

)-5

NO

S

6A 3

PIN

SOCK

ET-3

NOS,

6A 1W

AY S

WIT

CH W

ITH

6A, 3

PIN

SOC

KET

(RAW

)-2No

s

TOTA

L LO

AD-2

0A, 1

PHAS

E IN

DUST

RIAL

SO

CKET

with

20A

SPN

MCB

-4No

s

6A 1W

AY S

WIT

CH W

ITH

6A, 3

PIN

SOC

KET

(RAW

)-1No

s SPAR

E

R8

16ASP

MCB

Y7

SPAR

E

16ASP

MCB

Y8

SPAR

E

16ASP

MCB

TOTA

L LO

AD-6

A 1W

AY S

WIT

CH W

ITH

6A, 3

PIN

SO

CKET

(RAW

)-3NO

S

ROOM

NAM

E-MO

DEL M

AKIN

G AR

EA

TOTA

L W

ATT-

800W

TOTA

L LO

AD-2

0A 1

WAY

SW

ITCH

WIT

H 20

A, 6

PIN

SOCK

ET(R

AW) -

4NO

S.

B7

SPAR

E

16ASP

MCB

B8

SPAR

E

16ASP

MCB

ROOM

NAM

E-MO

NORA

IL TR

ACK

TOTA

L W

ATT-

180W

6A 3

PIN

SOCK

ET -3

NOS.

ROOM

NAM

E-MO

NORA

IL TR

ACK

TOTA

L W

ATT-

180W

6A 3

PIN

SOCK

ET -3

NOS.

ROOM

NAM

E-FO

RKLIF

T BA

TTER

Y CH

ARGI

NG A

REA

TOTA

L W

ATT-

120W

6A 3

PIN

SOCK

ET -2

NOS.

40A DPRCBO100mA

40A DPRCBO100mA

SPDB28WAY, TPN , DBLOCATION-ELECTRICAL PANEL ROOM GROUND FLOORCONNECTED LOAD:- 4.44KW

16ASP

MCB

R1 R2 R3 R4

R

4C x 6Sqmm, CU.Arm., XLPE , Cable

40A, FPMCB

Y1 Y2 Y3 Y4

Y

B1 B2 B3 B4

B

32A DPRCBO100mA

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

16ASP

MCB

TOTA

L W

ATT-

500W

TOTA

L LO

AD-6

A 1W

AY S

WIT

CH W

ITH

6A,3

PIN

SOCK

ET(R

AW)-5

NOS

32A DPRCBO100mA

32A DPRCBO100mA

ROO

M N

AME-

FACU

LTY

R00M

-1,2

,3,5

TOTA

L W

ATT-

300W

ROO

M N

AME-

CHAI

RMAN

OFF

ICE,

RESE

ARCH

SCH

OLA

R RO

OM

-2

ROO

M N

AME-

LAB

TECH

NICI

ANS

TOTA

L W

ATT-

600W

SPAR

E

SPAR

E

ROO

M N

AME-

CONF

EREN

CE R

OO

M

TOTA

L W

ATT-

300W

ROO

M N

AME-

GEN

TS T

OIL

ET,S

ERVI

CE D

UCT

TOTA

L W

ATT-

420W

TOTA

L LOA

D-6A

1WAY

SW

ITCH

WIT

H 6A

,3PIN

SOC

KET(

RAW

)-03N

OS

6A 3

PIN

SO

CKET

-2No

.

ROO

M N

AME-

LADI

ES T

OIL

ET,T

OIL

ET F

OR

PHYS

ICAL

LY C

HALL

ENG

ED

TOTA

L W

ATT-

420W

SPAR

E

ROO

M N

AME-

TEA

ROO

M,IT

/SER

VER

ROO

M,1

.25m

WID

E PA

SSAG

E

TOTA

L W

ATT-

400W

TOTA

L LO

AD-6

A 1W

AY S

WIT

CH W

ITH

6A,3

PIN

SOCK

ET(R

AW)-0

4NO

S

6A 3

PIN

SO

CKET

-2No

.

ROO

M N

AME-

LIBR

ARY/

MEE

TING

TOTA

L W

ATT-

800W

20A

, 1PH

ASE

INDU

STRI

AL S

OCK

ET w

ith 2

0A S

PN M

CB-1

NO

S

20A

, 1PH

ASE

INDU

STRI

AL S

OCK

ET w

ith 2

0A S

PN M

CB-1

NO

S

ROO

M N

AME-

CONT

ROL

ROO

M

TOTA

L W

ATT-

700W

20A

, 1PH

ASE

INDU

STRI

AL S

OCK

ET w

ith 2

0A S

PN M

CB-1

NO

S

TOTA

L LO

AD-6

A 1W

AY S

WIT

CH W

ITH

6A,3

PIN

SOCK

ET(R

AW)-3

NOS

TOTA

L LO

AD-6

A 1W

AY S

WIT

CH W

ITH

6A,3

PIN

SOCK

ET(R

AW)-3

NOS

TOTA

L LO

AD-6

A 1W

AY S

WIT

CH W

ITH

6A,3

PIN

SOCK

ET(R

AW)-3

NOS

TOTA

L LO

AD-6

A 1W

AY S

WIT

CH W

ITH

6A,3

PIN

SOCK

ET(R

AW)-3

NOS

TOTA

L LO

AD-6

A 1W

AY S

WIT

CH W

ITH

6A,3

PIN

SOCK

ET(R

AW)-1

NOS

TOTA

L LO

AD-6

A 1W

AY S

WIT

CH W

ITH

6A,3

PIN

SOCK

ET(R

AW)-1

NOS

TPDB18WAY, TPN , DBLOCATION-ELECTRICAL PANEL ROOM GROUND FLOORCONNECTED LOAD:- 6 KW

32ATP

MCB

4C x 6Sqmm, CU.Arm., XLPE , Cable

32ATP

MCB

TOTA

L W

ATT-

1000

W

30A,

3PH

ASE

IND

UST

RIA

L SO

CKE

T w

ith 3

0A T

P M

CB-

2NO

S

RO

OM

NAM

E- M

ON

OR

AIL

TRAC

K

C1 C2

TOTA

L W

ATT-

1000

W

32ATP

MCB

C3

32ATP

MCB

C5

SPAR

E

63A, FPMCB

30A,

3PH

ASE

IND

UST

RIA

L SO

CKE

T w

ith 3

0A T

P M

CB-

2NO

S

32ATP

MCB

C4

32ATP

MCB

C6

RO

OM

NAM

E- M

ON

OR

AIL

TRAC

K

30A,

3PH

ASE

IND

UST

RIA

L SO

CKE

T w

ith 3

0A T

P M

CB-

2NO

S

RO

OM

NAM

E- M

ON

OR

AIL

TRAC

K

TOTA

L W

ATT-

1000

W

30A,

3PH

ASE

IND

UST

RIA

L SO

CKE

T w

ith 3

0A T

P M

CB-

2NO

S

RO

OM

NAM

E- M

ON

OR

AIL

TRAC

K

TOTA

L W

ATT-

1000

W

30A,

3PH

ASE

IND

UST

RIA

L SO

CKE

T w

ith 3

0A T

P M

CB-

2NO

S

RO

OM

NAM

E- M

ON

OR

AIL

TRAC

K/PV

C C

UR

TAIN

TOTA

L W

ATT-

1000

W

30A,

3PH

ASE

IND

UST

RIA

L SO

CKE

T w

ith 3

0A T

P M

CB-

2NO

S

RO

OM

NAM

E- M

ON

OR

AIL

TRAC

K/PV

C C

UR

TAIN

TOTA

L W

ATT-

1000

W

32ATP

MCB

C7

32ATP

MCB

C8

SPAR

E

TPDB216WAY, TPN , DBLOCATION-ELECTRICAL PANEL ROOM GROUND FLOORCONNECTED LOAD:- 4 KW

32ATP

MCB

4C x 6Sqmm, CU.Arm., XLPE , Cable

32ATP

MCB

C1 C2

32ATP

MCB

C3

32ATP

MCB

C5

SPAR

E

63A, FPMCB

32ATP

MCB

C4

32ATP

MCB

C6

32ATP

MCB

C7

ROOM

NAM

E- E

LECT

RICA

L RO

OM

TOTA

L W

ATT-

500

W

32ATP

MCB

C8

ROOM

NAM

E- F

ORKL

IFT

BATT

ERY

CHAR

GING

ARE

A

TOTA

L W

ATT-

100

0W

ROOM

NAM

E- F

ORKL

IFT

BATT

ERY

CHAR

GING

ARE

A

TOTA

L W

ATT-

100

0W

ROOM

NAM

E- P

ANEL

ROO

M

TOTA

L W

ATT-

500

W

ROOM

NAM

E- IN

CUBA

TION

CEN

TER

TOTA

L W

ATT-

500

W

ROOM

NAM

E- C

ONTR

OL R

OOM

TOTA

L W

ATT-

500

W

SPAR

E

30A,

3PH

ASE

IND

UST

RIA

L SO

CKE

T w

ith 3

0A T

P M

CB-

1NO

S

30A,

3PH

ASE

IND

UST

RIA

L SO

CKE

T w

ith 3

0A T

P M

CB-

2NO

S

30A,

3PH

ASE

IND

UST

RIA

L SO

CKE

T w

ith 3

0A T

P M

CB-

2NO

S

30A,

3PH

ASE

IND

UST

RIA

L SO

CKE

T w

ith 3

0A T

P M

CB-

1NO

S

30A,

3PH

ASE

IND

UST

RIA

L SO

CKE

T w

ith 3

0A T

P M

CB-

1NO

S

30A,

3PH

ASE

IND

UST

RIA

L SO

CKE

T w

ith 3

0A T

P M

CB-

1NO

S

4C x 2.5Sqmm, CU.Arm., XLPE , Cable

4C x 2.5Sqmm, CU.Arm., XLPE , Cable

4C x 2.5Sqmm, CU.Arm., XLPE , Cable

3.5C x 35Sqmm, AL.Arm., XLPE , Cable

3.5C x 50Sqmm, AL.Arm., XLPE , Cable

4C x 2.5Sqmm, CU.Arm., XLPE , Cable

4C x 6Sqmm, CU.Arm., XLPE , Cable

3.5C x 35Sqmm, AL.Arm., XLPE , Cable

3.5C x 50Sqmm, AL.Arm., XLPE , Cable 240 kVAR APFC PANEL

F1

0-500A

2A, SP MCB-3NOS

ON OFF TRIP

R Y B

L

F2 F3 F4 F5 F6 F7

A

INCOMER500A TP 25kA, MCCBWITH O/C,SC

3PH,433V/50Hz, 500A AL.BUSBAR 25kA FOR 1 SEC.

2RUNS X 150SQ.MMX 3.5C A2XFY CABLE

CT 1- 3500/5A5VA,CL-1

2A, SP MCB-3NOS

0-500VV

TH

L

TH

L

TH

L

TH

L

TH

240KVAR APFC PANELQTY : 1NosCABLE ENTRY - TOP

FEEDER No.BREAKER RATINGBREAKING CAPACITY IN kAFEEDER DESCRIPTION

C C C C C

25kA5KVAR

25kA5KVAR

25kA10KVAR

25kA20KVAR

25kA25KVAR

25kA25KVAR 50KVAR

25kA

16A,TPN,MCCB

16A,TPN,MCCB

25A,TPN,MCCB

40A,TPN,MCCB

63A,TPN,MCCB

16A MCCB 25A MCCB 40A MCCB 63A MCCB 63A MCCB 100A MCCB16A MCCB

L

TH

C

63A,TPN,MCCB

F8

L

TH

C

100A,TPN,MCCB

F9

L

TH

C

100A,TPN,MCCB

25kA50KVAR

100A MCCB25kA

50KVAR

100A MCCB

F10

L

TH

C

100A,TPN,MCCB

APFCRELAYFROM MAIN LT PANEL

CT TERMINAL

9 STAGE APFCRELAY

KEY SLD

KUVELKAR SALKAR ASSOCIATESCONSULTING ENGINEERS

DRAFT COPYFOR TENDERINGFOR APPROVALFOR EXECUTION

INDIAN INSTITUTE OF TECHNOLOGYKHARAGPUR

PROPOSED DEEP AND SHALLOW WATER MANEUVERINGAND SEAKEEPING BASIN FACILITY FOR OCEAN

ENGINEERING AND NAVAL ARCHITECTURE DEPARTMENT

DRG.NO: IIT_OENA_CYC_KSA_DWG_ELE_02_KEY SLD

DK FIRE SERVICES

Page 65

AutoCAD SHX Text
I>
AutoCAD SHX Text
E
AutoCAD SHX Text
S2
AutoCAD SHX Text
S1
AutoCAD SHX Text
ASS
AutoCAD SHX Text
VSS
AutoCAD SHX Text
Particulars:-
AutoCAD SHX Text
00
AutoCAD SHX Text
-
AutoCAD SHX Text
REV.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
A1
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
N.T.S.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text
FOR APPROVAL
AutoCAD SHX Text
DATE
AutoCAD SHX Text
03.01.2021
AutoCAD SHX Text
REV.
AutoCAD SHX Text
00
AutoCAD SHX Text
CHK
AutoCAD SHX Text
R.P
AutoCAD SHX Text
DRN
AutoCAD SHX Text
S.K.A
AutoCAD SHX Text
APR
AutoCAD SHX Text
K.B.S
AutoCAD SHX Text
Project:-
AutoCAD SHX Text
Client:-
AutoCAD SHX Text
Electrical Design Associate:-
AutoCAD SHX Text
A-2 RAMAKANT APTS.
AutoCAD SHX Text
OPP. PHARMACY COLLEGE
AutoCAD SHX Text
TEL. +91 832 2227527
AutoCAD SHX Text
ST. INEZ PANAJI GOA
AutoCAD SHX Text
Website: www.ksa-india.com
AutoCAD SHX Text
%%UHEAD OFFICE
AutoCAD SHX Text
4G, RUSHABH CHAMBERS,
AutoCAD SHX Text
MAKWANA ROAD,
AutoCAD SHX Text
MUMBAI 400 059
AutoCAD SHX Text
MAROL, ANDHERI (E)
AutoCAD SHX Text
%%UBRANCH OFFICE
AutoCAD SHX Text
BEVERLY PARK, MIRA ROAD (E), THANE MUMBAI - 401107
AutoCAD SHX Text
OFFICE NO. 20, 1st FLOOR, A-WING, DEV PARADISE,
AutoCAD SHX Text
TEL. 022-28100402 Web: www.dkfireservices.com