Biomedical Equipmentcatalogue 2012- 2013

join the european network of experts in conservation - incubation - sterilisation

BIOMEDICAL N

ETWORK EUROPEAN

Spain

Portugal

Great Britain

France

Switzerland

GermanyBelgium

Russia

Czech Republic

Poland

Austria

Italy

Hungary

Slovenia

Croatia

Denmark

Norway

Sweden

Finland

Iceland

Bulgaria

Turkye

Israel

Macedonia

Albania

Greece

Cyprus

Malta

Bosnia

Serbia Montenegro

Biomedical Equipmentcatalogue 2012- 2013

NetherlandsLihuania

Latvia

Estonia

Slovakia

2

What’s in a name?

As you can see, this new ‘SANYO’ catalogue is now aPanasonic catalogue, but the products and the customerexperience are still the same.On 1st April 2012 the SANYO Biomedical company inEurope (SEEE) became the Panasonic Biomedicalcompany (PHCBE), so from that date the name on ourBiomedical equipment also changed to Panasonic.

After more than 25 years of success in Europe this is animportant step for our company. Bringing newengineering resources to the group will result in newproducts and even greater technical innovation.

The European sales and service organisation you areused to working with is not changing! You will have thesame personal contacts, the same high service level and,above all, the same experience. This is because oursuccess over the years has been built on mutual trustand understanding – between our customers and ourcompanies in the UK, France and The Netherlands;between our company and dealers in more than 40countries; and among our worldwide colleagues.

I sincerely want to thank our customers and colleaguesfor the success we have achieved. Without you we couldnot proudly say that we are the market leader in manycountries worldwide in ULT freezers and CO2 incubators.Without you we could not deliver tailor-made solutions inso many countries.

From now on you will see the name of ‘Panasonic’ on ourequipment, a company well known throughout the worldfor inventing many state-of-the-art electronic productsand making the impossible possible.As our respected customer you can trust us and expect100% commitment from our company to support youand your research. It is certain that as a PanasonicBiomedical company we will offer many innovative new‘Ideas for Life’!

Hans BrokPanasonic Biomedical

Sales Europe B.V.

BIOMEDICAL NETWORK EUR

OPEAN

Join the benefits of our network

Incubation

4

ContentsConservation

Introduction Panasonic Biomedical Sales Europe B. V. 6About Panasonic 8Service 10Synergy in Europe 12Vision on Safety 14

-150ºC/-152ºC Freezers MDF-1156 / MDF-1156ATN 18MDF-C2156VAN 22

-86ºC Freezers MDF-U500VX / MDF-U700VX 26MDF-U33V / MDF-U55V / MDF-U74V / MDF-U76V 32MDF-C8V1 40MDF-U3386S / MDF-U5386S / MDF-U7386S 42MDF-U4186S 46MDF-193 / MDF-394 / MDF-594 / MDF-794 48

-30ºC/-40˚C Freezers MDF-U5412 52MDF-137 / MDF-237 / MDF-436 / MDF-U334 / MDF-U443 / 54MDF-U5312 / MDF-U537D / MDF-U731M 56

Inventory Rack System Panasonic Inventory Racks 60Pharmaceutical refrigerators with Freezer MPR-414F / MPR-215F 62Pharmaceutical refrigerators MPR-1411 / MPR-1411R / MPR-721 / MPR-721R 66

MPR-1014 / MPR-1014R / MPR-514 / MPR-514R 70MPR-161D(H) / MPR-311D(H) 74

Bloodbank Refrigerators MBR-305GR / MBR-704GR / MBR-1405GR / MBR-107D(H) / MBR-506D(H) 78

Isothermal Freezers CBS Isothermal -190°C Dry Storage Freezers 82Isothermal Carousel 86

Liquid Nitrogen Storage Controlled Rate Freezer 86Standard LN2 Freezers 87CBS Cryosystems 88Vapor shippers 88CBS Lab tanks 89

CoolProducts BioCision - CoolRack®, CoolBox™, CoolCell® 90

CO2 Incubators MCO-80IC Large Scale Incubator 96MCO-20AIC 100MCO-19AIC(UV) 104MCO-18AC(UV) 110MCO-5AC(UV) 114

Water jacketed CO2 Incubator MCO-175 118Multi-gas Incubators MCO-19M(UV) 120

MCO-5M(UV) 124Plant growth chamber MLR-352 / MLR-352H 126Cooled and HeatedIncubators MIR-154 / MIR-254 / MIR-554 / MIR-162 / MIR-262 130Orbital Shaker MIR-S100 / MIR-S100C 136

Autoclaves MLS-3751L / MLS-3781L 142MLS-2420U / MLS-3020U 146

Ovens MOV-112 / MOV-212 / MOV-112F / MOV-212F / MOV-112S / MOV-212S 152

Specifications (All Products) 154

Sterilisation

14º30’.45.00”N 14º30’45.00”E

St. John’s Co-Cathedral, Valetta, Malta

Name: Christopher BusuttilLocation in our network:Scientific Consultant forPanasonic Biomedical products at Evolve LTD, Malta.favourite place: St. John’s Co-Cathedral,Valetta, Malta. Because of theattention to detail in everycorner which leads to grandeur.Majestic.

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA - BIOMEDICA

L N ET

WORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

6

Panasonic Biomedical Sales Europe B. V.

Since April 1st 2012 Panasonic Biomedical Sales Europe B.V. is the new name for SANYO

Biomedical as a result of the completion of SANYO’s merger with Panasonic. We will continue

to maintain and improve our high quality standards for our products and customer service.

In addition, as a Panasonic company, we now have access to extensive research and

development resources that will continue our long standing leadership position in innovative

technologies, available via the Panasonic network of manufacturing and research facilities

worldwide.

We look forward to an exciting future and will continue to provide you with industry-leading

biomedical laboratory equipment, supported by the high quality service you rely on. Our

Number One priority is to continue to develop close, longstanding customer relationships

through our dedicated sales and service network.

7

Conservation system

-152ºC/-150ºC/-86ºC Ultra-low temperature

freezers (MDF)

-40ºC/-35ºC/-30ºC Medical freezers (MDF)

Blood bank refrigerators (MBR)

Pharmaceutical refrigerators (MPR)

Freezers/refrigerators with dependable

internal temperatures.

Drying & sterilising system

Laboratory ovens (MOV)

Dry heat sterilisers (MOV)

Autoclaves (MLS)

Equipped with electronic control systems,

these models limit temperature fluctuations

Automated hospital pharmacy system

Automatic tablet counting and packaging

machine (ATC)

Based on microcomputer advances, this

unit enables accurate tablet dispensing and

reduces operating costs.

Medical and Laboratory equipment

Culturing system

CO2 Incubators (MCO)

Cooled incubators (MIR)

Heated incubators (MIR)

Plant growth chamber (MLR)

Incubators for advanced research

and testing.

Panasonic Biomedical Sales Europe B. V.

Panasonic Biomedical Sales Europe BV, part of the Panasonic HealthcareCompany (HCC), manages sales, marketing, logistics and technicalservice of Panasonic laboratory products throughout Europe (includingRussia and Turkey). Headquartered in the Netherlands with sales andservice organizations in the UK, France and the Netherlands.

In the Dutch warehouse, about 1.000 units are waiting to be delivereddirectly from stock. Within a couple of days, spare parts can be deliveredin every part of Europe. That’s one of the strengths of Panasonic’sBiomedical European sales organization.

8

About Panasonic

Panasonic has a dream for

this planet and the

everyday lives of people.

The world heritage sites are

natural and cultural

wonders of the world that n

eed to be preserved for

future generations - and th

e joy we experience

from our daily lives is a t

reasure just as

precious. By reducing carbon

emissions, more

efficient use of resources,

clean water efforts

and preserving biodiversity,

Panasonic has made

conservation of the eniviron

ment a priority for

all its business activities

worldwide.

Corporate brand

The Panasonic brand name was created in 1955 and was first used as a brand for audio

speakers. It is a combination of the words, "Pan", and "Sonic", sound and has a meaning of

bringing sound our Company creates to the world. Since 2008, it is used as the corporate

brand representing the Company, products and services.

Corporate vision

Panasonic aims to be the No.1 Green Innovation Company in the Electronics Industry in 2018,

the 100th anniversary of our founding. We will make the ‘environment’ central to all of our

business activities and take the lead in promoting the ‘Green Revolution’ which is taking place

around the world for the next generation. Specifically, we will work to realize our vision with

these two ‘innovations.’

9

We believe the best idea’s come from attentive observation ofeveryday living, carefully listening to customers... and aconstant commitment to making life easier, more comfortable,more fun.

Every Panasonic product or service is created from these“ideas for life.” Ideas to put a smile on your day and brightenour children’s horizon. Ideas that embrace the planet and bringpeople of all ages together.

As a gobal company, Panasonic has been in touch withdifferent peoples around the world for nearly a century. This puts us in a good position to translate “ideas for life” intothe values and lifestyles our customers aspire to.

Today you will find our name on products and services thatconnect with every facet of daily life. This “whole life”perspective is what makes Panasonic such a trusted brand inso many languages, and every day we work to earn that trust.

That’s our promise to you.

Brand Promise

Panasonic generates ideas for life... today and tomorrow. Through innovative thinking, we are

committed to enriching people’s lives around the world.

10

Service

Let us help you to protect your results - At Panasonic we appreciate how much your

samples and products are worth to you. Your chosen equipment has been manufactured

using world leading technology and specialist engineering, so it is important that we

continue to provide the best support and care possible to maximise the potential and

lifespan of your equipment. We have a dedicated team of Panasonic Service Specialists

who are trained to carry out repairs and service to our exacting standards, ensuring the

support you need during the life of your equipment.

Using our many years of experience and collaboration with our customers, we have

designed a number of service options to suit your requirements and budget.

During a Preventative Maintenance visit, using the latest technical information and

recommended test equipment, our specialists will carry out extensive tests, and make

any necessary adjustments to provide optimum performance.

11

l Dedicated Service Team focusing

on Panasonic Biomedical Products

l Comprehensive range of

Preventative Maintenance Plans

l In Warranty Maintenance

l Free Technical Support

l Installation

l Commissioning

l Calibration

l Validation

l Repairs

l Fully equipped workshop

l Genuine Panasonic spares

Name: Igor SpierenburgLocation in our network:Service Manager, PanasonicBiomedical Sales Europe B.V.,Etten Leur, The Netherlands.Favourite place: Brouwersdam, Zeeland. The Deltaworks have been built in the lastcentury. Technically this is oneof the 7 modern wonders of the world.

leading technology

Delta works, Brouwersdam, Zeeland

51º29’.38.51”N 3º50.38.51”E

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

Service Training InformationPanasonic Biomedical Sales Europe B.V. offers field servicetraining courses to third party service providers and our Europeandistributors on all laboratory products offered in Europe.

Our field training courses are directed toward refrigeration,electronic and biomedical technicians already familiar with thebasics of troubleshooting refrigeration and/or electronicequipment and can be customized to reflect the needs of theindividuals being trained.

Panasonic provides a comprehensive approach that includestheory and hands on instruction to maximize the benefits in theleast amount of time, utilizing the latest technology availablethrough a variety of media. We recognize the fact that skilledpeople are a valuable asset to the institutions they are servicing.Our unique field training approach allows for proper training onequipment without the disruption and expense of having yourskilled people unavailable for long stretches of time.

At Panasonic, we realize that to remain leaders in our industry,we must ensure that the quality of our product is maintainedthrough the integrity of our service offerings and the network ofindividuals who support our product in the field with the most up-to-date information available. Therefore, we offer our trainingcourses at minimal cost to qualified individuals and institutions.

Synergy in Europe

Working together with one goal - Panasonic Biomedical has established a worldwide

reputation as a manufacturer of high quality medical equipment over the past twenty five

years. Together with the high standard of service we deliver, it makes us a major player in the

biomedical market.

Logically we want our Panasonic dealers to offer you the same high standard of service that

belongs to our equipment. Therefore Panasonic only works with dealers that do guarantee

this quality. So whether you buy directly from us, or from one of our European distributors,

Name: Vicenç Garcia Guasch

Location in our network:CEO VERTEX Technics S.L.Panasonic’s new distributor in Spain

Favourite place: Park Guell, Barcelona, Spain

BIOMEDICAL NETWORK - DEN

MARK -

BIOMEDICAL NETWOR

K - HUNGARY -

BIOMEDICAL NETWOR

K - GERMANY-

BIOMEDICAL NETWOR

K - AUSTRIA -

BIOMEDICAL

N E

TWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

- BIOMEDICAL NETW

ORK -

ESPANA-

BIOMEDICAL NETWORK SWITZERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK - ITALY-

12

working side by side with our customers

you are always sure that maintenance will be

done by Panasonic certified service

engineers who have received full, hands-on

training for all Panasonic products.

In this way Panasonic provides their

customers with the best products and

service! or In this way Panasonic guarantees

the best products and service for their

customers!

Park Guell, Barcelona, Spain

41º24.50.85”N 2º09’.08.93”E

Service will only be done by Panasonic trained and certified engineers

13

14

Vision on Safety

14

45º58.34.00”N 7º39’.30.65”E

Name: Lukas Obrist

Location in our network:

Sales Area Manager

Labtec Services AG,

Switzerland.

favourite place:

Matterhorn, Switzerland.

Matterhorn, Switzerland

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

15

Medical Device Directive

MCO-19AIC

MBR-305GR

MDF-U55V

MDF-U74V

Panasonic has become one of the first companies in our industry to introduce Medical Device

certification to underline our strong commitment to product design, quality and safety.

In 2010, Panasonic was awarded certification by TÜV-Süd to manufacture blood bank refrigerators,

freezers and incubators as Class IIa Medical Devices according to the directives 93/42/EEC and

2007/47/EC. At the same time our quality systems were updated to the latest ISO9001 and ISO13485

standards.

The use of refrigeration products and cell culture incubators for the preservation and cultivation of cells

and tissues for human use in transfusion, regenerative medicine and cell therapy is set to expand.

In anticipation of these developing technologies and possible changes in the regulatory landscape,

Panasonic began to introduce Medical Device certified products in 2011. The first models to be

certified include the:

• MDF-U55V, MDF-U74V and MDF-U700VX ultra-low freezers.

• MBR-305GR Blood bank refrigerator.

• MCO-19AIC CO2 Incubator with rapid Hydrogen peroxide vapour decontamination option.

0123

Panasonic Healthcare Co., Ltd, Gunma Factory is certified for: Quality management system: ISO9001Medical devices quality management system: ISO13485

16

Vision on Conservation

InnovationOur reputation is built upon world-class design andrefrigeration systems developed specifically for ultra-low temperature applications. In fact, Panasonic haspioneered the development of new technologies forultra-low temperature storage from the -152°C freezer,the introduction of application specific CFC-Freerefrigerants and the first -86°C freezer with VacuumInsulation (VIP).

More recently Panasonic introduced the nextgeneration of compressors for ultra-low freezers. CoolSafe compressors provide new levels of durability withsignificantly reduced power consumption, heat outputand noise.

World Class DesignPerformance - Panasonic refrigeration systems offersuperior performance and durability, even in highambient temperatures and in response to frequentdoor openings. The cooling system also maintainsuniform temperatures throughout the freezer, which isespecially important when validation is required.

Low Frost Design - Fully insulated inner doors,advanced gasket design and heated door framescombat excessive ice build-up and ensure an effectiveseal against ambient air. This reduces routinemaintenance and keeps samples safe.

Vacuum Insulation (VIP) - Panasonic was the firstcompany to introduce vacuum insulation panels toultra-low temperature freezers. The Panasonic range ofVIP freezers provide typically 25% more storagecapacity for a given floor area saving valuablelaboratory space.

Sample Security - Advanced microprocessor controlsconstantly monitor freezer operation and ambientconditions to ensure reliable operation. Extensiveaudio-visual alarms and remote alarm contacts giveimmediate notice of a fault condition. Back-up andmonitoring options are available.

Refrigeration cycleThe compressor compressesrefrigerant gas and sends it to thecondenser which transfers heat energyto the air. Under pressure, this allowsthe gas to change state to a liquid.The now cool refrigerant liquid travelsto the capillary tube, which reducesthe pressure. When the cool liquidrefrigerant enters the evaporator at areduced pressure it will want to turnback into a gas. The only way it cando this is to absorb heat energy, thuscooling the inside of the freezer orrefrigerator. The now warm refrigerantgas returns to the compressor tobegin the cycle again.

The role of the lubrication oil is toprevent the moving parts of thecompressor from failing. Lubrication oilwill exit the compressor with therefrigerant making it important that

these two are able to mix. This willallow the lubrication oil to return to thecompressor without collecting in smalltubes or corners thus causing ablockage of the gas or liquidrefrigerant flow. (commonly referred toas oil logging).

The above explains the commonsingle compressor system, which istypically used to achieve temperaturesdown to -40ºC to -50ºC.

To achieve temperatures of -86ºC orbelow it is common to use a dual orcascade refrigeration system. Acascade system utilizes two separaterefrigeration systems called the lowand high stages. These stages share acommon heat exchange area. Thecondenser of the low stage is theevaporator of the high stage. Thismeans the low stage is responsible for

removing the heat from the storagechamber and the high stage removesthe heat from the low stage.

l -152°C Ultra-low Freezersl -86°C VIP Upright Freezersl -86°C Chest and Upright Freezersl Plasma Freezersl -30°/-40°C Biomedical Freezers l Inventory rack system l Medical Pharmaceutical Refrigerators andEnviro-Centers

l Panasonic Bio Securel Blood Bank Refrigeratorsl Laboratory Refrigeratorsl Isothermal Freezersl Liquid Nitrogen Storage

Air cooled condensor

Refrigerant &Lubrication oil

High stage compressor

Low stage compressor

Evaporatorchamber

Capillary tubes

Heat exchanger

-40ºC

17

The Heart of Ultra-Low Temperature Freezing

Name: Angela Skorobogataja

Location in our network:

Export Area Manager,

Panasonic Biomedical Sales

Europe B.V., EttenLeur,

The Netherlands

Favourite place:

Russian forest in wintertime

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

65º27’.38.45”N 124º07’.25.50”E

Russian Forest

18

-152ºC Freezers MDF-1156 / MDF-1156ATN

Achieves stable long-term preservation of cells and tissues.In preserving cells or tissues at ultra-low temperatures, the point is toprevent amorphous ice crystals from recrystalizing within and outside thecells. These ice crystals have smaller diameters than the smallestsubstances (4,000 to 7,000A) that compose cells or tissues.When ice crystals become amorphous, they are stored using cryoprotectiveagents such as glycerine and dimethyl sulfoxide (Me2SO). The speed of icecrystal formation is thus further restricted during preservation below a certaintemperature, and complete vitrification is possible. -130°C is therecrystallization point of pure water in the ultra-low temperature zone. This isthe temperature at which amorphous ice crystals recrystallize.

For a mixed solution containing Me2SO and other cryoprotectants, recentresearch confirms that recrystallization occurs around -115ºC. Thus samplesmaintained in an ultra-low temperature freezer at -152º C, far lower than therecrystallization point, can be semi-permanently preserved. Suchpreservation maintains vitrification without further crystallization within andoutside cells. Other recent findings show that preserving cattle sperm at -135°C is insufficient, and also that superconductivity experiments requiretemperatures of at least -148ºC. These cases show the increased necessityof -152ºC freezing.

The world of -152ºC

Why freeze to –152°C ?Recrystallization mechanism

Hexagonalcrystal

Cubic crystal

Amorphousice crystal

-80ºC

-130ºCRecrystallization

Point

-152ºC

47º29’.47.96”N 19º02’.33.98”E

Budapest, Hungary

Name: Laszlo Schwikker

Location in the Panasonic

network:Sales Representat

ive.

Auro-Science Consulting Kft,

Hungary.

Favourite place:

Chain Bridge in Budapest with

the castle in the background.

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WAY - BIOMEDICAL NETWORK - T

URKEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERLAND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

19

-152ºC Freezers MDF-1156 / MDF-1156ATN

The world of -152ºCUntil recently, liquid preservation containerswere mainly used when preserving valuablesamples over long periods. This methodhowever, involved troublesome liquid controland the dangers of a liquid supply. Inaddition, mycoplasma etc. could cause celland tissue contamination in liquid phasepreservation. As a solution to this problem,demand for vapour phase preservation hasincreased. In preservation with liquid Nitrogenvapour, temperatures can rise toapproximately -150ºC, almost the same asthe ultra-low temperature freezer’s innercabinet temperature of -152ºC. And freezerpreservation provides users with numerousadvantages; no worries about samplecontamination, no liquid supply problems, nodanger of sudden liquid eruptions, and lowoperational costs. This freezer provides easierand more stable long-term storage below therecrystallization point than ever before.

Features

Budapest, Hungary

MDF-1156128 LITRES81 2” BOXES54 3” BOXES

HCFC-Free special mixed refrigerantPanasonic has developed a special mixed refrigerant, replacingchlorofluorocarbons (HCFCs) that deplete the ozone layer. This new coolingsystem virtually eliminates damage to the earth’s environment.

Specially designed compressor and cascade refrigeration system foran ultra-low temperature of -152ºCA highly efficient, exclusive compressor has been specially developed andincorporated in the freezing unit. A refrigeration circuit with the Cool Safecompressor cascade refrigeration system enhances reliability of long-termpreservation. With a powerful low noise design afforded by traditional ultra-low temperature technology, this freezer delivers durable, stable cooling.

Microprocessor temperature control with LED digital display allowsaccurate temperature controlAccurate temperature setting, confirmation and operation are all possiblethrough microprocessor temperature control with a LED digital display andflat key data entry. The world’s first electronically controlled freezer, thismodel maintains inner cabinet temperature at an ultra-low -152ºC (ambient temperature of 30ºC), far lower than the recrystallizationpoint for pure water (-130ºC). This low temperature provides an ideal

-152ºC Freezers MDF-1156 / MDF-1156ATN

Effect of ambient temp. onholding time of liquefied gas

20

preservation environment for long-term storage.

High-efficiency oil separator for stable ultra-low temperature environmentsCompressors continuously repeat highlycompressed operations, so lubricant oil isessential to prevent abrasion and seizure. Butwhen lubricant oil circulates in the refrigerationcircuit, piping becomes clogged and results incompressor damage. Incorporating anexclusive high-efficiency oil separator, theMDF-1156 effectively separates lubricant oilfrom refrigerant, offering a stable ultra-lowtemperature environment.

Special foamed-in-place polyurethaneinsulation materialThe temperature difference between the insideand outside of the MDF-1156 unit reaches amaximum of 182ºC. In the ultra-low temperaturerange below -100ºC, ordinary foamed-in-placepolyurethane insulating material can becomecracked and warped. Specially designed to

withstand low temperatures, Panasonic’s foamed-in-place polyurethane is 170 mm thickand highly resistant to extreme temperaturedifferences, thus helping maintain innertemperature stability.

Various alarm and safety devices forprotecting valuable samplesMicroprocessor-controlled filter-clogged checkfunction protects the refrigeration circuit.High temperature warning equipmentautomatically indicates when the temperaturedeviates 15ºC from the set temperature. Thepower failure alarm lamp and buzzer areactivated in case of power failure or irregulartemperature increase. A remote alarm contactis fitted. ATN models are also equipped withan auxiliary back-up system for liquidNitrogen.

Inner cabinet’s easy-to-use designAccommodates world standard 2”and3”boxes.

600

mdf 1156

1400

94

557

2

66

7

80

0

450

400

800

600

mdf 1156

1400

94

557

2

66

7

80

0

450

400

800

600

mdf 1156

1400

94

557

2

66

7

80

0

450

400

800

Dimensions

Unit: mm

21

-152ºC Freezers MDF-1156 / MDF-1156ATN

Performance data MDF-1156 / MDF-1156ATN

Pull-down characteristics Temp. distribution inside cabinet

-150ºC setting,ambient temperature 35ºC, no load

at: 20ºC low-temp. side operation rate 72% ON: 10min OFF: 4 min

Effect of ambient temp. on inside temp.

Pull-up characteristics during power failure

ApplicationsPreservationl Cancer research: Tumor Cell

Preservationl Blood or Bone Marrow

Preservationl Bacteria Research: Virus

Preservationl Sperm & Fertilized Ovum (Bull,

Goat, Horse, Pig, Chicken)Preservation

l Plant Cell Preservation (ie. Pollen)l Monoclonal Antibody Preservation

Environmental Experimentl Superconductivity & Electronics

Experimentation (-148ºC)

Userl Universityl Private Institutel Public Research Centerl Hospital

Options

LCO2 backup system CVK-A (MDF-1156) LN2 backup systemwith recorder CVK-ATN2 (MDF-1156)

Temperature chart recorder (-170ºC to +30ºC ) MTR-155H Chart paper RP-155 Ink pen DF-38FPStorage case MDF-49SCInventory racks see page 60

22

Ultra-low -150ºC freezer with third generation VIP insulation.The freezer is equipped with Panasonic developedthird generation Vacuum Insulation Panels. This improved VIP insulation is extremely efficient andresults in a -150ºC freezer with a capacity of 140world standard 2” boxes, the largest capacity -150ºCfreezer in the world!

New control panel with graphic LCD displayAll the alarm functions, self-diagnostic notificationsand a digital graph of the temperature are available inthe new, specially designed LCD display. The bluedisplay provides a clear image of the temperature andgives a notification in the case of abnormalities intemperature, ambient temperature, power supply etc.

New Cool Safe compressorsThe MDF-C2156VAN is equipped with the new Cool Safe compressors. The compressors achieve a10% higher energy conservation and theaerodynamically designed and placed components inthe refrigeration compartment provide superior airflow,

-150ºC Freezer MDF-C2156VAN

45º26’.02.88”N 12º20’.18.59”E

Name: Andrea Crisanti

Location in our network

:

Sales and Marketing Mana

ger,

Analitical Control De Mo

ri,

Italy.

Favourite place:

Venice, because it is th

e

most beautiful and well

known part of Italy.

Venice, Italy

The world’s largest capacity -150°C freezer

BIOMEDIC

AL N ETWORK - DENMARK -

BIOMEDICAL N ETWORK - HUNGARY

-

BIO

MEDICAL N ETWORK - GERMANY-

BIO

MEDICAL N ETWORK - AUSTRIA -

BIOMEDICAL NETWORK - SWE

DEN -

BIOMEDIC

AL NETWORK NETHERLANDS

BIOMEDIC

AL N ETWORK - UK -

BIOMEDIC

AL N ETWORK - NORWAY -

BIOMEDIC

AL N ETWORK - TURKEY-

BIO

MEDICAL N ETWORK - ESPANA-

BIOMEDIC

AL N ETWORK SWITZERLAND

BIOMEDIC

AL N ETWORK - RUSSIA -

BIOMEDIC

AL N ETWORK - GREECE -

BIOMEDIC

AL N ETWORK - MALTA -

BIO

MEDICAL N ETWORK - ITALY-

23

making it possible to significantly reduce the stress to the freezer andcontributing to excellent durability.

New double door gasketsThe temperature difference between the inside of the cabinet and theambient temperature can be up to 180ºC! To prevent leaking the MDF-C2156VAN is equipped with a new double door gasket.

Environmentally friendlyThe MDF-C2156VAN utilises binary mixed non-HCFC refrigerants. The new Vacuum Insulation Panels and double door gaskets reducethe power consumption.

-150ºC Freezer MDF-C2156VAN

MDF-2156231 LITRES150 2” BOXES105 3” BOXES

++++

+++++++++++ TwinGuard TwinGuardDUALºCOOL TECHNOLOGY

VACUUM INSULATION

VIPPlus VIPPlus+

24

-150ºC Freezer MDF-C2156VAN

Tem

pera

ture

(˚C)

Time (hour)

Tim

e (h

our)

Ambient temperature (˚C)

LN2 back up system operation characteristics

0 2010 30 40

20

25

10

15

5

Ambient temp. and maintenance of –135˚C by injection of LN2 (50kg)

Pull-down characteristics

40200

–20

–120

–40

–140

–60

–160

–80–100

0 2 204 6 8 10 181612 14

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Tem

pera

ture

(˚C)

Time (hour)

40200

–20

–120

–40

–140

–60

–160

–80–100

0 2 204 6 8 10 181612 14

Pull-up characteristics during power failure

Performance data MDF-C2156VAN

Unit: mm

The Next Generation Compressors: Cool Safe

A wide range of Ultra-low temperature freezers.We’ve selected a line-up of different types and models of ultra-low freezer which can achieve and maintain temperaturesdown to -152ºC. Designed to meet your needs Panasonic ultra-low freezers are suitable for uses such as long termpreservation, testing, frozen storage etc.

Specially Designed Compressor for Ultra-LowTemperature.Evolving through continuous innovation; the reliability and

performance of our specially designed ULT compressors hasalways been unmatched. Our ULT freezers are considered tobe the top of the market all over the world. Where others wouldbe satisfied with such performance, we are always searchingfor improvements.

This resulted in developing the next generation of compressors:Cool Safe.

The Cool Safe compressors achieve a 10% higher energy

25

-150ºC Freezer MDF-C2156VAN10

10

1730

1125

760

615

11.5

53

495

465

802

105

924

765 46864

Dimensions

conservation and the aerodynamicallydesigned and placed components in therefrigeration compartment provide superiorairflow, making it possible to significantlyreduce the stress to the freezer andcontributing to excellent durability.

Why change a winning team is a phrase that isoften heard. We changed it to obtain evenbetter performance.

A compressor that produces less heat thanbefore, a noise level even lower than beforeand a reliability and performance even moreunmatched.

We are the only ULT freezer manufacturercapable of developing our own compressors.This is what we do and we are good at it!

Unit: mm

Options

Temperature chart recorder (-170ºC to +30ºC) MTR-155H Chart paper RP-155 Ink pen DF-38FPMounting kit MDF-S30150Storage case MDF-49SCInventory racks see page 60

Communications Interface MTR-480

26

-86ºC Freezers MDF-U500VX / MDF-U700VX Dual Cooling Freezer

l Extreme secure Dual Cooling System

l Evolutionary design VIP PLUS insulation

l Energy saving ECO mode operation

l Intelligent controller interface with data log function

Ultra-low temperature Dual Cooling Freezer

Name: Vassilis Barbas

Location in our network:

Director of one of Panasonic’s

oldest Biomedical relations in

Europe; Hellenic Labware S.A.

Athens, Greece.

Favourite place:

Acropolis because it is the

symbol of the ancient herritage

of Greece.

BIOMEDICAL NETWORK - D

ENMARK -

BIOMEDICAL NET

WORK - HUNGARY -

BIOMEDICAL NET

WORK - GERMANY-

BIOMEDICAL NET

WORK - AUSTRIA -

BIOMEDIC

AL N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NE

THERLANDS

BIOMEDICAL NETWORK

- UK -

BIOMEDICAL NETWORK - N

ORWAY -

BIOMEDICAL NETWORK -

TURKEY-

BIOMEDICAL NE

TW

ORK - ESPANA-

BIOMEDICAL NETWORK SW

ITZERLAND BIOMEDICAL NETWOR

K - RU

SSIA -

BIOMEDICAL NETWORK -

GREECE -

BIOMEDICAL NETWORK -

MALTA -

BIOMEDICAL N

ETWORK - ITALY-

MDF-U5OOVX519 LITRES352 2” BOXES224 3” BOXES

++++

+++++++++++ TwinGuard TwinGuardDUALºCOOL TECHNOLOGY

VACUUM INSULATION

VIPPlus VIPPlus+

++++

+++++++++++ TwinGuard TwinGuardDUALºCOOL TECHNOLOGY

VACUUM INSULATION

VIPPlus VIPPlus+

27

-86ºC Freezers MDF-U500VX / MDF-U700VX Dual Cooling Freezer

-86Du

al°Co

olTec

hnolo

gy1

Features

37º58’.21.10”N 23º43’.34.20”E

Acropolis, Athens, Greece

Secure storage with New Dual Cooling SystemThe Twin Guard Dual Cooling System is newly designed to provide the highestlevel of security for valuable biological samples. Two individually controlledcompressors provide a reliable and exceptionally stable -86°C ultra-lowtemperature environment. In the case of unexpected failure of one of the coolingcircuits, the other circuit will maintain the freezer in the -70°C range, protectingsamples until service can be arranged.Developed for use with conventional inventory racks and boxes, the Twin GuardSeries is ideal for storage of sensitive, high-value samples.

L A BH F

-86ºC

A B

A B

MDF-U700VX728 LITRES528 2” BOXES336 3” BOXES

28

-86ºC Freezers MDF-U500VX / MDF-U700VX Dual Cooling Freezer

General Features & Benefits

What It Is

-86 DualºCool Refrigeration Technology

ECO mode Performance

Environmentally Friendly Refrigerants

Filterless Condenser Design

Patented VIP PLUS Vacuum PanelComposite Insulation

Integrated Graphical LCD Control Center

Structural Enhancement

Compliant to International Standards

What It Does

Two independent refrigeration systemsoperate together or individually, dependingon demand and performance environment.

Two independent refrigeration systemsrunning in overlapping cycles,

Eliminates potential for ozone depletionwhile maintaining cooling capacity.

Transfers energy from the refrigerationsystem with minimal heat output.

Combines high-efficiency vacuum-panelswith conventional polyurethane structuralfoam and barrier film into a high-tech wallassembly.

Combines all control, alarm, monitoringand data management functions into asingle door-mounted system controller.

Integrates inventory management, accessand site installation.

Assures quality standards, safety andperformance criteria are met or exceeded.

Why It Is Important

One refrigeration system is alwaysavailable to back-up the other in the eventof a component failure.

ECO mode optimizes run time, minimizesenergy costs and maximizes interiortemperature uniformity.

Complies with the Montreal Protocol andIEC for safety and efficiency.

Eliminates the need for an air filter;optimizes heat exchange and minimizescompressor heat built-up over time.

Increases interior volume withinconventional dimensions offering morestorage capacity per m2 of occupied floorspace.

High visibility LCD display provides aconvenient user interface to setpoints,current and previous temperature status,alarm parameters, internal diagnostics,communications and security.

Cabinet design attributes include high-strength, lockable door latches and doors,latchable inner doors, adjustable shelves,vvacuum release port and locking castersto simplify operation, installation and tosatisfy local codes.

Essential for compliance with LEEDs,RoHS, UL and other third-party standardsand recommended practices.

29

High efficiency insulation with VIP PLUS TechnologyPanasonic’s latest development in vacuum insulation is VIP PLUS technology. This revolutionary vacuum insulationcabinet construction reduces the wall thickness byapproximately one half and achieves up to 30% morestorage capacity than a conventionally insulated freezer,maximizing storage capacity and saving valuable lab space.Just as importantly, VIP PLUS insulation contributes to the overall energy efficiency of the MDF-U500VX andMDF-U700VX.

Industry first intelligent ECO mode operationThe industry’s first “ECO mode” operation on these Twin Guard models achieves approximately 15% energysaving compared to a conventional model. In ECO mode, themicroprocessor controller constantly monitors the load status

on the freezer to optimize the operation of the twocompressors to minimize energy use whilst protectingvaluable samples.

-86ºC Freezers MDF-U500VX / MDF-U700VX Dual Cooling Freezer

Barrier FilmVIP Plus

InteriorRigid foamedpolyurethane

Pattern1 Pattern3Pattern2

ECO mode operation image

NORMAL mode operation image

Pull-down

Pull-down

Stable temperature

Stable temperature

30

Intelligent interfaceThe new LCD display control panel is located at eye level forimproved visibility and ease of use. A data log function storesrecent temperature data allowing the user to quickly checkfreezer performance. This data can be directly downloaded toa PC via an optional data interface.

User-Friendly DesignComprehensive alarms including high/low temperatures, doorajar, power failure alarm and part replacement notificationhelp to keepsamples safe even in an emergency.l A vacuum release port allows smooth door opening when

the door is tightened by negative pressure generated fromtemperature difference between chamber and ambientenvironment.

l Filterless construction eliminates bothersome filtercleaning.

l New rugged, one-handed outer door latch allows apadlock to be attached.

-86ºC Freezers MDF-U500VX / MDF-U700VX Dual Cooling Freezer

Positive feedback tactile input buttons

Menu call button

Buzzer silence temporarilymutes audible alarm

Audible alarm

Digital LCD display with alphanumeric information

Pop-up menu

Message display

Display contrast adjustment

Visual alarm indicator

Positive feedback tactile entryand function keys

Dimensions

MDF-U500VX MDF-U700VX

836770630

10791010870

48 4818 1240 870

795600

105122140 870

795600

105

1990

2010

156013

80

1400

1540

1545

1558

450

450

MDF-U500VX MDF-U700VX

836770630

10791010870

48 4818 1240 870

795600

105122140 870

795600

105

1990

2010

156013

80

1400

1540

1545

1558

450

450

31

Options

LCO2 backup system CVK-UB2 Circular temperature chart recorder (-100ºC to +40ºC) MTR-G85Chart paper RP-G85 Ink pen PG-R Temperature chart recorder (-100ºC to +50ºC) MTR-85HChart paper RP-85 Ink pen DF-38FP Recorder housing (for MTR-85H) MDF-S3085

Communications Interface MTR-480

Drawers3 drawer set for MDF-U500VX MDF-50R

Small inner door kit1 set of 2 inner doors for MDF-U500VX MDF-5ID1 set of 2 inner doors for MDF-U700VX MDF-7ID

Inventory racks see page 60

-86ºC Freezers MDF-U500VX / MDF-U700VX Dual Cooling Freezer

MDF-U500VX

MDF-U700VX

0

-20

-40

-60

-80

Pull-up while a power failure

Operation with one compressor

Normal cycle operation (-80˚C setting)

0 1 2 3 4 5 6 7 8 9 10 11 12

Pull-up c haracteristics during power failure

P ull-down c haracteristics

Tem

per

atur

e. (°

C)

Tem

per

atur

e. (°

C)

Central air temp. in cabinetAmbient temp. 30°C, No-Load

Time (hour)Time (hour)

0 1 2 3 4 5 6 7 8 9 10 11 12

Time (hour)

40

20

0

-20

-40

-60

-80

-1000 1 2 3 4 5 6 7 8 9 10 11 12

Pull-up characteristics during power failurePull-down characteristics

Pull-up characteristics during power failurePull-down characteristics

Tem

per

atur

e. (°

C)

Time (hour)

40

20

0

-20

-40

-60

-80

-1000 1 2 3 4 5 6 7 8 9 10 11 12

Central air temp. in cabinetAmbient temp. 30°C, No-Load0

-20

-40

-60

-80

Pull-up during power failure

Single compressor operation(kept at or below -65ºC)

Normal cycle operation (-80˚C setting)

Cha

mb

er t

emp

. (˚C

)

0

-20

-40

-60

-80

Pull-up while a power failure

Operation with one compressor

Normal cycle operation (-80˚C setting)

0 1 2 3 4 5 6 7 8 9 10 11 12

Pull-up c haracteristics during power failure

P ull-down c haracteristics

Tem

per

atur

e. (°

C)

Tem

per

atur

e. (°

C)

Central air temp. in cabinetAmbient temp. 30°C, No-Load

Time (hour)Time (hour)

0 1 2 3 4 5 6 7 8 9 10 11 12

Time (hour)

40

20

0

-20

-40

-60

-80

-1000 1 2 3 4 5 6 7 8 9 10 11 12

Pull-up characteristics during power failurePull-down characteristics

Pull-up characteristics during power failurePull-down characteristics

Tem

per

atur

e. (°

C)

Time (hour)

40

20

0

-20

-40

-60

-80

-1000 1 2 3 4 5 6 7 8 9 10 11 12

Central air temp. in cabinetAmbient temp. 30°C, No-Load0

-20

-40

-60

-80

Pull-up during power failure

Single compressor operation(kept at or below -65ºC)

Normal cycle operation (-80˚C setting)

Cha

mb

er t

emp

. (˚C

)

Performance data MDF-U500VX

Performance data MDF-U700VX

Menu call buttonDigital LCD display with alphanumeric information

Pop-up menu

Message display

32

-86ºC Freezers MDF-U33V / MDF-U55V / MDF-U74V / MDF-U76V Ultra-low temperature VIP freezers

Panasonic VIP ultra-low freezers represent the industry’smost complete combination of refrigeration, control,alarm, monitoring and accessibility for product safety at -86°C. Ideal for sample storage in repositories, hospitals,clinics and medical research facilities, the VIP Series isdesigned to reduce energy consumption.

Enhanced PerformancePanasonic VIP Series upright freezers offer advanced cabinetdesign, electronics, refrigeration and critical components forenhanced product security, better performance and costeffective operation at -86°C.

The Panasonic cascade refrigeration system uses Panasonicdesigned compressors specific to ultra-low applications forhigh-performance, reliability and peace of mind. Refrigerationcomponents are carefully selected and matched for optimumoperation under demanding laboratory environments.l Increased cooling capacity improves temperature recovery

after door openings.l The evaporator coil surrounding the chamber interior is

strategically designed to provide optimum temperatureuniformity from top-to-bottom.

l Quieter operation is achieved through condenser fan bladedesign, noise reduction insulation, anti-vibration systems andinternal compressor noise reduction.

Energy-efficient, ultra-low temperature VIP freezers

l Industry leading -86°C preservation for uniformity, reliability and reduced footprint.

l New Panasonic Cool Safe refrigeration system designed to deliver energy-saving,

high performance cooling.

l Secure storage for valuable research and clinical samples.

48º12’.23.83”N 16º22.58.15”E

Vienna, Austria

Which freezer will you choose?

Conventional Panasonic MDF-U55VInsulation With VIP Insulation

240 ca. 352 ca. Capacity2”boxes 2’’boxes

Insulation

Name: Gerald Feyerer

Location in our network:

Head of TechSupport & Servic

e,

VWR Austria, Vienna, Austria

.

Favourite place:

Traditional Wiener Café,

because there is a world

famous coffee tradition in

Vienna.

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

++++

+++++++++++ TwinGuard TwinGuardDUALºCOOL TECHNOLOGY

VACUUM INSULATION

VIPPlus VIPPlus+

-86ºC Freezers MDF-U33V / MDF-U55V / MDF-U74V / MDF-U76V Ultra-low temperature VIP freezers

l Voltage boost and surge protection devices providedependable operation over wider power ranges andenvironmental conditions.

l The rear ventilation cover combines with the aerodynamicallydesigned and positioned components in the refrigerationcompartment to provide superior airflow, drastically reducingthe load on the freezer and contributing to improved durability.

Patented VIP Vacuum Insulation PanelThe combination of multiple high-performance vacuum panelswith high-density foam insulation provides a reduced wallthickness for maximum interior volume. Panasonic VIP ULTfreezers provide up to 30% more storage capacity than aconventionally insulated freezer without increasing the footprint.The MDF-U76V features next generation VIP PLUS vacuumpanels for increased energy efficiency and cooling performance.

Panasonic Heat Exchanger Design Increases EnergyEfficiency1

Every traditional ultra-low freezer design utilizes a heat exchanger.By increasing the efficiency of the heat exchanger through animproved new design incorporating more surface area contact at

critical points in the refrigeration system, we are able to improvethe overall efficiency and reduce compressor running time. Thisalong with other improvements to the heat exchanger translatesto a substantial increase in energy efficiency.

Inner Doors Improve UniformityHigh-strength, sealing, insulated inner doors help minimizechange in interior temperatures during routine door openings andensure maximum chamber uniformity. Easy-In/Easy-OutPanasonic inner door latches seal firmly against the cabinet withone hand operation.

Microprocessor Control Comprehensive setpoint, alarm, monitoring and diagnosticfunctions supervised by Panasonic-built microprocessorcontroller with digital display of all functions. A Status Alert featureconstantly monitors ambient and system conditions and notifiesthe user of any abnormalities before a problem occurs.

1Applies to models MDF-U55V, MDF-U76V

33

MDF-U55V519 LITRES352 2” BOXES224 3” BOXES

MDF-U33V333 LITRES216 2” BOXES144 3” BOXES

-86ºC Freezers MDF-U33V / MDF-U55V / MDF-U74V / MDF-U76V Ultra-low temperature VIP freezers

MDF-U74V728 LITRES528 2” BOXES336 3” BOXES

MDF-U76V728 LITRES528 2” BOXES336 3” BOXES

34

What It Is

Energy-Efficient Refrigeration

Panasonic Cool Safe Compressors

Environmentally FriendlyRefrigerants

Integrated Control Center

Structural Enhancement

Compliant to InternationalStandards

Ergonomic Design

What It Does

Microprocessor control over all coolingfunctions delivers cooling on demand.

Specific to ultra-low applications. Reducescompressor temperatures internally andexternally.

Eliminates potential for ozone depletion whilemaintaining cooling capacity.

Combines all control, alarm, monitoring anddata management functions into a singlesystem.

Integrates inventory management, accessand site installation.

Assures quality standards, safety andperformance criteria are met or exceeded.

One-handed outer and inner door latchesand quiet-running compressors improveconvenience, minimize sound.

Why It Is Important

Optimizes run time to minimize energy consumption.

Increases compressor longevity and reliability.Reduces heat output and lowers HVAC loads in room.

Complies with the Montreal Protocol and IEC forsafety and efficiency.

High visibility LED display provides a convenient userinterface to setpoints, alarm parameters, internaldiagnostics, communications and security.

Cabinet design features include high-strength, lockable door latches and doors, latchable inner doors,adjustable shelves and locking casters to simplifyoperation and installation, and to satisfy local codes.

Essential for compliance with CE, RoHS, and otherthird-party standards and recommended practices.

Easy access to controls, displays and inventory racks,while low noise operation permits a wider choice ofinstallation locations.

VIP Series Features, Benefits and Performance Advantages

One of the most important concepts in designing a superiorenergy saving ultra-low freezer is how efficiently heat isexchanged between the high and low stage circuits. Byproviding optimum heat exchange pathways in the design,it not only increases efficiency of the system, leading togreater energy savings, but it will also have an effect ofreducing stress on the compressors, leading to greater

overall system reliability. Panasonic’s new capillary tubeheat exchanger is but the latest step in increasing theavailable heat exchange areas in the system. This patentpending innovation significantly increases the efficiency ofthe entire system. The end result is less energyconsumption, while improving the overall efficiency of thefreezer.

Energy efficient cascade cooling system

Water Cooled OptionNow a water cooled condenser option is available forfacilities equipped with chilled recirculating watersystems. This option utilizes the cascade refrigerationdesign to reuse energy produced by an ultra-lowfreezer while delivering additional energy-savings andhigh performance cooling. Ideal for material storage inrepositories, hospitals, clinics and medical researchfacilities, the water cooled system provides a range ofbenefits.l Energy efficiencyl Cost savingl Re-use of energyl Faster recovery timel Improved sample security

Ultra-LowTemperature

Freezer

Plate Heat Exchanger

Transport viaphase 2

How It Works

Phase 1Heat generated from the freezer compartment is transferred to a water circuit using a plate heat exchanger.

Phase 2Transport the absorbed heat/energy from the freezer.

Phase 3Possibility to re-use heat/energy for other heat/energy demandingsystems.

Eco Friendly Technology – helping toreduce running costs andenvironmental impact.Panasonic space-saving VIP ultra-lowfreezers offer ‘best in class’ energyefficiency, whilst delivering exceptionalcooling performance and durability forstoring valuable research and clinicalsamples.l A microprocessor controller

oversees the refrigeration system to

regulate cooling cycles, reducingenergy consumption.

l Energy efficient Panasonic CoolSafe compressor technology forlower internal compressor temperatures and reduced air-conditioning loads.

l A new low stage capillary tube heatexchanger provides optimum heattransfer leading to greater operatingefficiency (Models MDF-U55V,

MDF-U76V).l Advanced cabinet insulation

technology for increased energyefficiency and cooling performance.

l Components are compliant with theRoHS directive on the use ofhazardous substances in electricaland electronic equipment.

l Commercially available, non-HCFCrefrigerants.

l Integrated noise reduction features.

18

16

14

12

10

8

6

4

2

0

14

12

10

8

6

4

2

0300 & 400 litres 500 litres 700 litres

Nominal freezer capacity

Pow

er c

onsu

mp

tion

kWh/

24h

Pow

er c

onsu

mp

tion

kWh/

year

/litr

e

Power Consumption Comparison‘Space-Saving’ Ultralow Upright Freezer

300 & 400 litres 500 litres 700 litres

Nominal freezer capacity

Power Consumption Comparison‘Space-Saving’ Ultralow Upright Freezer

Panasonic Brand N Brand T

18

16

14

12

10

8

6

4

2

0

14

12

10

8

6

4

2

0300 & 400 litres 500 litres 700 litres

Nominal freezer capacity

Pow

er c

onsu

mp

tion

kWh/

24h

Pow

er c

onsu

mp

tion

kWh/

year

/litr

e

Power Consumption Comparison‘Space-Saving’ Ultralow Upright Freezer

300 & 400 litres 500 litres 700 litres

Nominal freezer capacity

Power Consumption Comparison‘Space-Saving’ Ultralow Upright Freezer

Panasonic Brand N Brand T

Published data. Freezer set-point -80°C, ambient temperatureof 20-25°C, 50Hz power supply. Power consumption willdepend on loading and operating conditions.

Power Consumption ComparisonSpace-saving vacuum insulation panel ultra-low upright freezers

-86ºC Freezers MDF-U33V / MDF-U55V / MDF-U74V / MDF-U76V Ultra-low temperature VIP freezers

35

36

-86ºC Freezers MDF-U33V / MDF-U55V / MDF-U74V / MDF-U76V Ultra-low temperature VIP freezers

Status alert function uses predictive intelligence todetermine if freezer is operating within specifications

under existing environmental conditions.

Digital display defaults to actual chambertemperature. Display mode changes when

setpoint, alarm parameters, programming anddiagnostic functions are performed.

Panasonic Ni-MH battery powers control memory andalarm functions during power failure.

Filter indicator lamp glows when electrostatic filterrequires removal for cleaning.

Press to set temperature; set button isalso used for other diagnostic functions.

Alarm setpoints are factory set 10ºC above and belowtemperature setpoint. Alarm parameters are adjustable.

Alarm indicator lamp glows when freezer isin alarm condition.

Buzzer key temporarilymutes audible alarm.

Alarm ring-back is factoryset for 30 minutes

(adjustable). Alarm test verifies readiness of alarmfunction and Ni-MH battery charge.

Setpoint entry advances digitaldisplay to next position.

Compressor start-up delaysequence delays re-startafter building power failure;allows facility power to reachequilibrium to permit smoothfreezer start-up.

Setpoint entry advances digitaldisplay to next value from 0 to 9.

Door alarm indicator has 2minute delay until audiblealarm activates; delay timeis adjustable.

Audible alarm.

Integrated Microprocessor Control System

The Panasonic microprocessor control system is secure, easy to use and comprehensive. Setpoint, alarm parameters andself-diagnostic functions are accessed through a tamper-resistant keypad. The control panel is door-mounted and angledfor easy access.

Barrier Film

VIP Plus

Interior

Rigid foamedpolyurethane

Multiple access portspermit insertion ofindependent probes,instrumentation or liquid Nitrogen or liquid CO2 back-up injectors.

Insulated and gasketed inner doorsseal inside to offer additionalprotection and uniformity. Inner door latches are standard.

Heated outer doorgasket and a 'hot-line' circulating hotrefrigerant gas around the door framehelp to prevent ice build-up.

Remote alarm contacts and optionalcommunication port available; see Options.

Vacuum relief valve(Available onMDF-U76V)

Panasonic designed Cool Safe compressors arespecifically designed for ultra-low temperatureapplications.

Commercially available HFC refrigerants are highlyefficient, environmentally safe and non-ozone depleting.

Front access to washable, electrostaticcondenser air filter for routine cleaning.

Temperature recorder(optional) mounts easily inpre-engineered mountingspace.

High impact, recessed castersand leveling feet simplifyinstallation.

Universal keyed door lock offersadded security.

Easy-In/Easy-Out door latch forsmooth, one-handed operation,positive seal against gasket.Provision for padlock.

37

-86ºC Freezers MDF-U33V / MDF-U55V / MDF-U74V / MDF-U76V Ultra-low temperature VIP freezers

38

-86ºC Freezers MDF-U33V / MDF-U55V / MDF-U74V / MDF-U76V Ultra-low temperature VIP freezers

481076

181010

870

2010

450

1560

795600

33 870 105

1400

1 555

11

1558 17

90

21770

839

630

1990

1540

45

0

48

1380

600

105870

11

795

1770

33

1545

54

MDF U33

105

30

1639

18490670

450

1860

1410

45733

1140

867795

897

600

481076

181010

870

1990

329

59

430

1560

795600

33 870 105

1400

1 555

11

1545 17

70

28

MDF-U33V

Dimensions

OptionsBack-up systemsLiquid CO2 back-up system CVK-UB2 Liquid N2 back-up system CVK-UBN2

RecordersCircular temperature chart recorder (-100ºC to +40ºC) MTR-G85Chart paper RP-G85Ink pen PG-R Strip temperature chart recorder (-100ºC to +50ºC) MTR-85HChart paper RP-85 Ink pen DF-38FP Recorder housing (for MTR-85H) MDF-S3085

CommunicationsCommunications Interface MTR-480

Drawers3 drawer set for MDF-U33V MDF-30R3 drawer set for MDF-U55V MDF-50R

Inner door kits1 set of 2 inner doors for MDF-U55V MDF-5ID1 set of 2 inner doors for MDF-U74V/MDF-U76V MDF-7ID

OtherInventory racks see page 60Water cooled condenser see page 35

CVK-UB2 MTR-G85MDF-50R

Unit: mm

0123The MDF-U55V and MDF-U74V are certified as ClassIIa Medical Devices (93/42/EECand 2007/47/EC) for medicalpurposes of storing cells, DNAand/or frozen plasma. (For EUcountries only)

39

-86ºC Freezers MDF-U33V / MDF-U55V / MDF-U74V / MDF-U76V Ultra-low temperature VIP freezers

Time (hour)

Time (hour)

Time (hour)

Tim

e (h

our)

Ambient temperature (˚C)

Pull-down characteristics Pull-up characteristics during power failure

CO2 backup system operation characteristics

Tem

per

atur

e (˚C

)Te

mp

erat

ure

(˚C)

525 530301 51 02

10

15

20

5

40

20

0

–20

–40

–60

40

20

0

-20

-40

-60

-80

-100

40

20

0

-20

-40

-60

-80

-100

–80

–100

Tem

per

atur

e (˚C

)

40

20

0

–20

–40

–60

–80

–1000

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

2 3 4 5 6 7 8 9 10 11 121 0 2 3 4 5 6 7 8 9 10 11 121

0 2 3 4 5 6 7 8 9 10 11 121

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Time (hour)

Tem

per

atur

e (˚C

)Te

mp

erat

ure

(˚C)

0-10-20-30-40-50-60-70-80-90

0-10-20-30-40-50-60-70-80-90

-100

0 1 2 3 4 5 6 7 8 9 10 11 12

0 1 2 3 4 5 6 7 8 9

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Tim

e (h

our)

Ambient temperature (˚C)525 530301 51 02

10

15

5

Time (hour)

Tem

per

atur

e (˚C

)Te

mp

erat

ure

(˚C)

Tem

per

atur

e (˚C

)

40

20

0

-20

-40

-60

-80

-100

0 1 2 3 4 5 6 7 8 9 10 11 12

Pull-down characteristics Pull-up characteristics duringpower failure

Pull-down characteristics

Pull-down characteristics

Pull-up characteristics duringpower failure

Pull-up characteristics duringpower failure

CO2 backup system operationcharacteristics

CO2 backup system operationcharacteristics

20

0

–20

–40

–60

–80

–100

Time (hour)

Time (hour)

5 25201510 30 35

20

10

15

5

Tim

e (h

our)

Ambient temperature (˚C)

5 25201510 30 35

20

10

15

5Ti

me

(hou

r)

Ambient temperature (˚C)

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

74

55

76

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Time (hour)

CO2 backup system operation characteristics

0 2 4 6 8 10 12 14

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Time (hour)

Time (hour)

Time (hour)

Tim

e (h

our)

Ambient temperature (˚C)

Pull-down characteristics Pull-up characteristics during power failure

CO2 backup system operation characteristics

Tem

per

atur

e (˚C

)Te

mp

erat

ure

(˚C)

525 530301 51 02

10

15

20

5

40

20

0

–20

–40

–60

40

20

0

-20

-40

-60

-80

-100

40

20

0

-20

-40

-60

-80

-100

–80

–100

Tem

per

atur

e (˚C

)

40

20

0

–20

–40

–60

–80

–1000

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

2 3 4 5 6 7 8 9 10 11 121 0 2 3 4 5 6 7 8 9 10 11 121

0 2 3 4 5 6 7 8 9 10 11 121

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Time (hour)

Tem

per

atur

e (˚C

)Te

mp

erat

ure

(˚C)

0-10-20-30-40-50-60-70-80-90

0-10-20-30-40-50-60-70-80-90

-100

0 1 2 3 4 5 6 7 8 9 10 11 12

0 1 2 3 4 5 6 7 8 9

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Tim

e (h

our)

Ambient temperature (˚C)525 530301 51 02

10

15

5

Time (hour)

Tem

per

atur

e (˚C

)Te

mp

erat

ure

(˚C)

Tem

per

atur

e (˚C

)

40

20

0

-20

-40

-60

-80

-100

0 1 2 3 4 5 6 7 8 9 10 11 12

Pull-down characteristics Pull-up characteristics duringpower failure

Pull-down characteristics

Pull-down characteristics

Pull-up characteristics duringpower failure

Pull-up characteristics duringpower failure

CO2 backup system operationcharacteristics

CO2 backup system operationcharacteristics

20

0

–20

–40

–60

–80

–100

Time (hour)

Time (hour)

5 25201510 30 35

20

10

15

5

Tim

e (h

our)

Ambient temperature (˚C)

5 25201510 30 35

20

10

15

5

Tim

e (h

our)

Ambient temperature (˚C)

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

74

55

76

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Time (hour)

CO2 backup system operation characteristics

0 2 4 6 8 10 12 14

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Performance data MDF-U76V

Performance data MDF-U74V

Time (hour)

Time (hour)

Time (hour)

Tim

e (h

our)

Ambient temperature (˚C)

Pull-down characteristics Pull-up characteristics during power failure

CO2 backup system operation characteristics

Tem

per

atur

e (˚C

)Te

mp

erat

ure

(˚C)

525 530301 51 02

10

15

20

5

40

20

0

–20

–40

–60

40

20

0

-20

-40

-60

-80

-100

40

20

0

-20

-40

-60

-80

-100

–80

–100

Tem

per

atur

e (˚C

)

40

20

0

–20

–40

–60

–80

–1000

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

2 3 4 5 6 7 8 9 10 11 121 0 2 3 4 5 6 7 8 9 10 11 121

0 2 3 4 5 6 7 8 9 10 11 121

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Time (hour)

Tem

per

atur

e (˚C

)Te

mp

erat

ure

(˚C)

0-10-20-30-40-50-60-70-80-90

0-10-20-30-40-50-60-70-80-90

-100

0 1 2 3 4 5 6 7 8 9 10 11 12

0 1 2 3 4 5 6 7 8 9

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Tim

e (h

our)

Ambient temperature (˚C)525 530301 51 02

10

15

5

Time (hour)

Tem

per

atur

e (˚C

)Te

mp

erat

ure

(˚C)

Tem

per

atur

e (˚C

)

40

20

0

-20

-40

-60

-80

-100

0 1 2 3 4 5 6 7 8 9 10 11 12

Pull-down characteristics Pull-up characteristics duringpower failure

Pull-down characteristics

Pull-down characteristics

Pull-up characteristics duringpower failure

Pull-up characteristics duringpower failure

CO2 backup system operationcharacteristics

CO2 backup system operationcharacteristics

20

0

–20

–40

–60

–80

–100

Time (hour)

Time (hour)

5 25201510 30 35

20

10

15

5

Tim

e (h

our)

Ambient temperature (˚C)

5 25201510 30 35

20

10

15

5

Tim

e (h

our)

Ambient temperature (˚C)

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

74

55

76

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Time (hour)

CO2 backup system operation characteristics

0 2 4 6 8 10 12 14

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Performance data MDF-U55V

Time (hour)

Time (hour)

Time (hour)

Tim

e (h

our)

Ambient temperature (˚C)

Pull-down characteristics Pull-up characteristics during power failure

CO2 backup system operation characteristics

Tem

per

atur

e (˚C

)Te

mp

erat

ure

(˚C)

525 530301 51 02

10

15

20

5

40

20

0

–20

–40

–60

40

20

0

-20

-40

-60

-80

-100

40

20

0

-20

-40

-60

-80

-100

–80

–100

Tem

per

atur

e (˚C

)

40

20

0

–20

–40

–60

–80

–1000

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

2 3 4 5 6 7 8 9 10 11 121 0 2 3 4 5 6 7 8 9 10 11 121

0 2 3 4 5 6 7 8 9 10 11 121

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Time (hour)

Tem

per

atur

e (˚C

)Te

mp

erat

ure

(˚C)

0-10-20-30-40-50-60-70-80-90

0-10-20-30-40-50-60-70-80-90

-100

0 1 2 3 4 5 6 7 8 9 10 11 12

0 1 2 3 4 5 6 7 8 9

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Tim

e (h

our)

Ambient temperature (˚C)525 530301 51 02

10

15

5

Time (hour)

Tem

per

atur

e (˚C

)Te

mp

erat

ure

(˚C)

Tem

per

atur

e (˚C

)

40

20

0

-20

-40

-60

-80

-100

0 1 2 3 4 5 6 7 8 9 10 11 12

Pull-down characteristics Pull-up characteristics duringpower failure

Pull-down characteristics

Pull-down characteristics

Pull-up characteristics duringpower failure

Pull-up characteristics duringpower failure

CO2 backup system operationcharacteristics

CO2 backup system operationcharacteristics

20

0

–20

–40

–60

–80

–100

Time (hour)

Time (hour)

5 25201510 30 35

20

10

15

5

Tim

e (h

our)

Ambient temperature (˚C)

5 25201510 30 35

20

10

15

5

Tim

e (h

our)

Ambient temperature (˚C)

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

74

55

76

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Time (hour)

CO2 backup system operation characteristics

0 2 4 6 8 10 12 14

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Performance data MDF-U33V

481076

181010

870

2010

450

1560

795600

33 870 105

1400

1 555

11

1558 17

90

21770

839

630

1990

1540

45

0

48

1380

600

105870

11

795

1770

33

1545

54

MDF U33

105

30

1639

18490670

450

1860

1410

45733

1140

867795

897

600

481076

181010

870

1990

329

59

430

1560

795600

33 870 105

1400

1 555

11

1545 17

70

28

481076

181010

870

2010

450

1560

795600

33 870 105

1400

1 555

11

1558 17

90

21770

839

630

1990

1540

45

0

48

1380

600

105870

11

795

1770

33

1545

54

MDF U33

105

30

1639

18490670

450

1860

1410

45733

1140

867795

897

600

481076

181010

870

1990

329

59

430

1560

795600

33 870 105

1400

1 555

11

1545 17

70

28

481076

181010

870

2010

450

1560

795600

33 870 105

1400

1 555

11

1558 17

90

21770

839

630

1990

1540

45

0

48

1380

600

105870

11

795

1770

33

1545

54

MDF U33

105

30

1639

18490670

450

1860

1410

45733

1140

867795

897

600

481076

181010

870

1990

329

59

430

1560

795600

33 870 105

1400

1 555

11

1545 17

70

28

MDF-U76VMDF-U55V MDF-U74VMDF-U33V

Dimensions

MTR-85H

40

-80ºC Freezers MDF-C8V1

l New VIP PLUS technology maximises storage capacity

l Filterless structure makes cleaning unnecessaryl Low noise designl Achieves energy savings of approx. 40%*

* Panasonic ComparisonMDF-C8V1Conventional model*

Capacity84LCapacity86L

0.377 m0.525 mInstallationspace

*Panasonic comparison

2 2

-80°C Ultra-Low TemperatureVIP Freezer

MDF-C8V184 LITRES

Name: Tommy Tarnsten

Location in our network:

Managing Director for

LabRum Klimat AB in Sweden.

Favourite place:

Stockholm archipelago.

It’s just beautiful,

peacefull, where you have

a possibility to be all

alone.

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K - HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY- ++++

+++++++++++ TwinGuard TwinGuardDUALºCOOL TECHNOLOGY

VACUUM INSULATION

VIPPlus VIPPlus+

41

-80ºC Freezers MDF-C8V1

Features

More advanced insulation system: VIP PLUSPanasonic’s more advanced insulation system VIP PLUSenables reducing the thickness of insulation to approximatelyone half compared to conventional systems. Small freezerssuch as MDF-C8V1 takes full advantage of this feature. Useof VIP PLUS insulation material on the front, left, and rightsides enables a smaller installation space with the highestclass storage capacity ratio.

New cooling circuit enables filterless structureA new cooling circuit makes the inconvenient customermaintenance procedure of filter cleaning unnecessary.

Newly developed single-compressor systemUse of a newly developed single-compressor systemachieves an approximately 40% reduction in powerconsumption and enables low-noise operation.

Pull-down characteristics Pull-up characteristics during power failure

CO2 backup system operation characteristics

40200

–20

–120

–40–60–80

–100

0 7652 83 41

Tem

pera

ture

(˚C)

Time (hour)

20

0

–20

–40

–60

–80

–1000 6 75321 84

Tem

pera

ture

(˚C)

Time (hour)

Central air temp. in cabinetAmbient temp. 30˚C, No-load

5 25201510 30 35

12

10

15

0

Tim

e (h

our)

Ambient temperature (˚C)

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

550

35

425

852

887

945

58 44

68539

729

405 490

Dimensions

Options

LCO2 backup system CVK-UB4 LN2 backup system CVK-UBN2Mounting plate for CVK-UB4 MDF-UBK Circular temperature chart recorder (-100ºC to +40ºC) MTR-G85Chart paper RP-G85 Ink pen PG-R Temperature chart recorder (-100ºC to +50ºC) MTR-85HChart paper RP-85 Ink pen DF-38FP Recorder housing (for the MTR-85H) MDF-S3085 Recorder sensor cover MTR-C8Inventory racks see page 60

Communications Interface MTR-480

-80°C Ultra-Low TemperatureVIP Freezer

MDF-C8V1

59º30’.49.32”N 19º23’.41.94”E

MDF-C8V1

Conventional model*

Rated power consumption

340W/330W

550W/600W

*Panasonic comparison (115V, 60Hz/230V, 50Hz)

Unit: mm

Stockholm archipelago, Sweden

42

-86ºC Freezers MDF-U3386S / MDF-U5386S / MDF-U7386S

Blood Animal & Plant TissueMicro

DrugsIndustrial

organisms equipment

0°C

Plasma

Quick plasmaFreezingRed cellPlateletsLymph cellsGranulocytes

Enzymes

Skin cellsInternalsOrgansDNAEmbryosCorneaBone marrow

RootsSeedsPollenCellsDNA

CellsYeast

Micro organisms

Virus

DrugsBloodSerumvaccines

For industryEquipment &Electronic parts

-10 °C

-20°C

-30°C

-35°C

-40°C

-50°C

-86°C

Low-temperature range applications

Ultra-low temperature upright freezers -86ºC

Panasonic offers a wide range of upright -86°Cfreezers to suit your individual storage needs. All ourfreezers feature the usual high-quality componentsyou would expect from Panasonic including HCFC-free refrigerants. All units feature full alarm systems toensure your samples are well protected and secure. Panasonic freezers ultilise a cascade cooling system,enabling ultra-low freezer temperatures to be reachedquickly and quietly. Microprocessor control maintainsthese temperatures accurately and reliably.

47º33’.28.11”N 10º44’.59.47”E

Name: Michael Ewald

Location in our network:

Managing Director of Panasonic’s

long lasting relation in Germany;

Ewald Innovationstechnik GmbH,

Germany.

Favourite place:

Neuschwanstein is one of the most

beautiful places in Germany;

The Alps, green meadows, small

vilages and dark forests.

It really looks like a fairy tale.

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K - AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSIA -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY- Neuschwanstein, Germany

43

-86ºC Freezers MDF-U3386S / MDF-U5386S / MDF-U7386S

MDF-U7386S / MDF-U5386Sl Cool Safe Compressorsl HFC refrigerantsl Microprocessor controll Temperature alarml Single action door latch l Adjustable levellersl Door key lockl Castersl Easy access filter

MDF-U5386S 483 LITRES320 2” BOXES192 3” BOXES

MDF-U7386S668 LITRES480 2” BOXES336 3” BOXES

Potential users

l Universitiesl Private enterprises,

Pharmaceutical companiesl Medical institutions, Hospitalsl Public research centres,

research institutes

44

MDF-U3386Sl Unique design and size targets the growing trend to personal freezers

and compact size. While this is a spacesaver there is no compromiseon features.

l Easy access and quick placement or locating of samples. l The foamed-in-place rigid polyurethane insulation is

HCFC-free as in all other Panasonic freezers.

l Features all of the technology, construction and reliability you havecome to expect from Panasonic freezers.

l Simplified maintenance with easy access filter. l Less formation of ice.

-86ºC Freezers MDF-U3386S / MDF-U5386S / MDF-U7386S

MDF-U3386S MDF-U5386S MDF-U7386S

MDF-U3386S MDF-U5386S MDF-U7386SUnit: mm

MDF-U3386S333 LITRES216 2” BOXES144 3” BOXES

Dimensions

-86ºC Freezers MDF-U3386S / MDF-U5386S / MDF-U7386S

45

Tem

pera

ture

(˚C)

Time (hour) Time (hour)

Tim

e (h

our)

Ambient temperature (˚C)

Pull-down characteristics Pull-up characteristics during power failure

CO2 backup system operation characteristics

Tem

pera

ture

(˚C)

40

20

0

–20

–40

–60

–80

–1000 2 4 6 8 10 10512 52 03 5314 51 02

40

20

0

–20

–40

–60

–80

–1000 2 4 6 8 10 12 14

20

15

10

5

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Performance data MDF-U3386S

Tem

pera

ture

(˚C)

Time (hour) Time (hour)

Tim

e (h

our)

Ambient temperature (˚C)

Pull-down characteristics Pull-up characteristics during power failure

CO2 backup system operation characteristics

Tem

pera

ture

(˚C)

40

20

0

–20

–40

–60

–80

–1000 2 4 6 8 10 12 14

40

20

0

–20

–40

–60

–80

–1000 2 4 6 8 10 12 14

Central air temp. in cabinetAmbient temp. 30˚C, No-load

50 3525201510 30

14

8

6

4

2

10

12

0

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Performance data MDF-U5386S

40

20

0

–20

–40

–60

–80

–1000 2 4 6 8 10 5012 35252014 1510

Tem

pera

ture

(˚C)

40

20

0

–20

–40

–60

–80

–1000 2 4 6 8 10 12 14

Tem

pera

ture

(˚C)

Time (hour) Time (hour)

Pull-up characteristics during power failure

30

12

8

6

4

2

10

0

Tim

e (h

our)

Ambient temperature (˚C)

CO2 backup system operation characteristics

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

Pull-down characteristics

Performance data MDF-U7386S

Backcover

CompressorsFront

Rear Air

The newly developed back cover combined withnew aerodynamically designed and placedcomponents in the refrigeration compartmentprovide superior air flow, making it possible todrastically reduce the stress on the freezer andcontributing to excellent durability.

Options

LCO2 backup system CVK-UB2 LN2 backup system CVK-UBN2 Circular temperature chart recorder (-100ºC to +40ºC) MTR-G85Chart paper RP-G85 Ink pen PG-R Temperature chart recorder (-100ºC to +50ºC) MTR-85HChart paper RP-85 Ink pen DF-38FP Recorder housing (for MTR-85H) MDF-S3085

Communications Interface MTR-480Inventory racks see page 60

Dimensions

46

-86ºC Freezers MDF-U4186S Chest freezers

MDF-U4186Sl Advanced refrigeration systeml Quiet operationl Enhanced securityl Removable inner doors for cleaning and defrosting

Evolutionary designl The newly developed refrigeration system and the

freezer structure offer a quiet experimentalenvironment.

l The newly developed back cover combined withnew aerodynamically designed and placed

components in the refrigeration compartmentprovide superior airflow, making it possible todrastically reduce the stress to the freezer andcontributing to excellent durability.

l Two independent and insulated inner doors preventcold air leakage.

Accessibilityl The condenser filter is situated at the bottom right

side of the front panel to make filter removal andcleaning easier.

20

1975

1200

870

620

105

30

62

795

780

520

1020

1975

1200

870

620

105

30

62

795

780

520

10

DimensionsMDF-U4186S

Performance data MDF-U4186S

Options

LCO2 backup system CVK-UB2 LN2 backup system CVK-UBN2 Temperature chart recorder (-100ºC to +50ºC) MTR-85HChart paper RP-85 Ink pen DF-38FP Recorder housing (for the MTR-85H) MDF-S3085

Communications Interface MTR-480Inventory racks see page 60

Unit: mm

40

20

0

–20

–40

–60

–80

–10004 6 8 10 512 35252014 1510

Tem

per

atur

e (˚C

)

40

20

0

–20

–40

–60

–80

–1000 2 4 6 8 10 12 142

Tem

per

atur

e (˚C

)

Time (hour) Time (hour)

Pull-up characteristics during power failure

30

20

15

10

5

Tim

e (h

our)

Ambient temperature (˚C)

CO2 backup system operation characteristics

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Pull-down characteristics

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

40

20

0

–20

–40

–60

–80

–10004 6 8 10 512 35252014 1510

Tem

per

atur

e (˚C

)

40

20

0

–20

–40

–60

–80

–1000 2 4 6 8 10 12 142

Tem

per

atur

e (˚C

)

Time (hour) Time (hour)

Pull-up characteristics during power failure

30

20

15

10

5

Tim

e (h

our)

Ambient temperature (˚C)

CO2 backup system operation characteristics

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Pull-down characteristics

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

40

20

0

–20

–40

–60

–80

–10004 6 8 10 512 35252014 1510

Tem

per

atur

e (˚C

)

40

20

0

–20

–40

–60

–80

–1000 2 4 6 8 10 12 142

Tem

per

atur

e (˚C

)

Time (hour) Time (hour)

Pull-up characteristics during power failure

30

20

15

10

5

Tim

e (h

our)

Ambient temperature (˚C)

CO2 backup system operation characteristics

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Pull-down characteristics

Ambient temp. and maintenance of –70˚C by injection of LCO2 (30kg)

MDF-U4186S382 LITRES192 2” BOXES

MDF-U4186S382 LITRES216 2” BOXES144 3” BOXES

-86ºC Freezers MDF-U4186S Chest freezers

Performance data MDF-U4186S

An Ideal Freezing Environment By Means of Foamed-in-place Insulation and the “Hot Line”.In Ultra-Low temperature freezers, effective insulation isextremely critical since the temperature difference between theoutside and the inner compartment can be as high as 115ºC.The insulation used in Panasonic’s ultra-low temperature chestfreezers is highly efficient rigid, foamed in place polyurethane. Moisture condensation at the top edges of the cabinet due todifferences in temperature inside and out causes frost and icingproblems, which may reduce heat insulation efficiency andobstruct lid movements. They are prevented by the “hot line”by means of which hot gas from the higher temperature circuitis circulated through the problem areas.

A Special Refrigerant and Oil to Maintain Stability andReliability.In order to expand refrigeration capacity, a special compoundrefrigerant has been used. This refrigerant relieves therefrigeration system of much of its load by evaporating at alower temperature level within the circuit. Also, a special gradeof refrigeration machine oil is used with the superior propertiesof high rate of recovery and outstanding resistance to heat andwear. This contributes to the long life and dependability of thefreezer unit as a whole.

Microprocessor Temperature Control with Digital Design.Precise setting and control is possible.The temperature inside the freezer can be set and monitoredeasily by means of very accurate microprocessor temperaturecontrol with digital display. The controller utilizes a platinumresistor (Pt 100) sensor which is precise and extremely durable.

Built-In Temperature & Power Failure Alarms (Lamp/Buzzer). Protecting Contents from Trouble.In case of power failure or an irregular rise in temperature, arechargeable, battery-operated indicator lamp and alarm will beactivated. Optional recorders automatically record the insidetemperature and an accessory LCO2 back-up system is self-activated when the freezer temperature increases. Thisequipment helps ensure that the contents will be protected inthe event of any power failure or mechanical trouble.

Innovative Design Easy to Operate.Overall operability and dependability are greatly enhanced byimproved design details. Highly durable hinges are used tosupport the lids so both opening and closing are facilitated. Lidhandles are equipped with a latch-locking system, and thecontrol panel is protected from accidental setting.

Panasonic’s Ultra-Low Temperature Chest freezers combine innovation with superior

performance and reliability. Ideal for maintaining stable internal temperatures, the secure

chest design is enhanced by super-efficient freezing technology and advanced features.

Freezer capacities range from economical to bulk, allowing you to maximize your long-term

preservation and storage environment.

47

48

-86ºC Freezers MDF-794 / MDF-594 / MDF-394 / MDF-193

These ultra-low temperature freezers are designed byPanasonic to maintain internal temperature as low as -86ºC, at an ambient temperature of +30ºC. They areideally suited for use in hospitals and laboratories, inlong-term preservation and storage of blood,specimens and components, and in testing of varioustypes. Ranging in size from economical chest freezer to

large-capacity, one of these models is sure to besuitable for your needs. Advanced features include amicroprocessor temperature control system with digitaltemperature display, a platinum resistance sensor forextra precision and reliability, a power failure warningsystem with built-in audible and visible indicators, andeasy-open/easy-close hinged lid.

Ultra-low temperature chest type freezers -86ºC

l A wide range of ultra-low temperature freezers to suit your needs from bulkpreservation to personal in-lab use.

l Ideal -86ºC freezing environment.l Specially designed Cool Safe compressors for ultra-low temperature.l Microprocessor temperature control with digital design for precise setting

and control.l Built-in temperature and power failure alarms (lamp/buzzer).

52º11.48.69”N 0º07’.53.23”E

Cambridge, United Kingdom

Name: Arun Parmar

Location in our network:

Sales Manager,

Panasonic Biomedical Sales

Europe B.V., Leicestershire,

United Kingdom.

Favourite place:

Cambridge since it is set in

such a tranquil cultural

location yet renown for its 800

years of University status known

world wide.

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

49

-86ºC Freezers MDF-794 / MDF-594 / MDF-394 / MDF-193

1 Power switch2 Back-up system switch (option)3 Back-up system test switch

(option)4 Remote alarm switch5 Temperature setting key6 Digit shift key7 Figure shift key

8 Entry key9 Alarm test key10 Buzzer key11 Alarm lamp and buzzer12 Filter clog check lamp13 Temperature display14 Temperature recorder (option)

Ultra-low temperature chest type freezers -86ºC

Options

LCO2 backup system CVK-A LN2 backup system CVK-UBN2Temperature chart recorder (-100ºC to +50ºC) MTR-85HChart paper RP-85 Ink pen DF-38FP Inventory racks see page 60

MDF-394309 LITRES189 2” BOXES126 3” BOXES

MDF-19386 LITRES42 2” BOXES30 3” BOXES

1280

762

795

1550

2010

500

53 770 38

861

105

1070

594

480

750

658

430

945

420

53 700 38

791

660

1400

1860

1120

530

105

945

53 800 38

891

520

MDF-393

762

1840795

2110

2570

500

77053 38

861

105

1070

-86ºC Freezers MDF-794 / MDF-594 / MDF-394 / MDF-193

Dimensions

MDF-594

1280

762

795

1550

2010

500

53 770 38

861

105

1070

594

480

750

658

430

945

420

53 700 38

791

660

1400

1860

1120

530

105

945

53 800 38

891

520

MDF-393

762

1840795

2110

2570

500

77053 38

861

105

1070

MDF-193

50

1280

762

795

1550

2010

500

53 770 38

861

105

1070

594

480

750

658

430

945

420

53 700 38

791

660

1400

1860

1120

530

105

945

53 800 38

891

520

MDF-393

762

1840795

2110

2570

500

77053 38

861

105

1070

MDF-394

MDF-794701 LITRES468 2” BOXES324 3” BOXES

MDF-594487 LITRES312 2” BOXES216 3” BOXES

1280

762

795

1550

2010

500

53 770 38

861

105

1070

594

480

750

658

430

945

420

53 700 38

791

660

1400

1860

1120

530

105

945

53 800 38

891

520

MDF-393

762

1840795

2110

2570

500

77053 38

861

105

1070

51

-86ºC Freezers MDF-794 / MDF-594 / MDF-394 / MDF-193Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

5

10

15

20

Ambient temp. ( C̊)

Tim

e (h

r.)

535 15 25 0301 20

SV of backup system –70 C̊LCO2 30kg

0 1 2 3 4 5 6 7 8 9 10Time (hr.)

Tem

p. (

˚C)

–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

0 1 2 3 4 5 6 7 8 9 10Time (hr.)

Ambient temp. ( C̊)Time (hr.) Time (hr.)

Ambient temp. ( C̊)Time (hr.) Time (hr.)

Ambient temp. ( C̊)Time (hr.) Time (hr.)

Tem

p. (

˚ C)

Tim

e (h

r.)

Tem

p. (

˚C)

Tem

p. (

˚ C)

Tim

e (h

r.)

Tem

p. (

˚C)

Tem

p. (

˚ C)

Tim

e (h

r.)

Tem

p. (

˚C)

Tem

p. (

˚ C)

–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

793

393

193

5

10

15

20

535 15 25 0301 200 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

5

10

15

20

535 15 25 0301 200 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

01020

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

01020

5 10 15 20 25 30 355

10

15

20

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

102030

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

SV of backup system –70 C̊LCO2 30kg

SV of backup system –70 C̊LCO2 30kg

SV of backup system –70 C̊LCO2 30kg

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

5

10

15

20

Ambient temp. ( C̊)

Tim

e (h

r.)

535 15 25 0301 20

SV of backup system –70 C̊LCO2 30kg

0 1 2 3 4 5 6 7 8 9 10Time (hr.)

Tem

p. (

˚C)

–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

0 1 2 3 4 5 6 7 8 9 10Time (hr.)

Ambient temp. ( C̊)Time (hr.) Time (hr.)

Ambient temp. ( C̊)Time (hr.) Time (hr.)

Ambient temp. ( C̊)Time (hr.) Time (hr.)

Tem

p. (

˚ C)

Tim

e (h

r.)

Tem

p. (

˚C)

Tem

p. (

˚ C)

Tim

e (h

r.)

Tem

p. (

˚C)

Tem

p. (

˚ C)

Tim

e (h

r.)

Tem

p. (

˚C)

Tem

p. (

˚ C)

–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

793

393

193

5

10

15

20

535 15 25 0301 200 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

5

10

15

20

535 15 25 0301 200 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

01020

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

01020

5 10 15 20 25 30 355

10

15

20

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

102030

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

SV of backup system –70 C̊LCO2 30kg

SV of backup system –70 C̊LCO2 30kg

SV of backup system –70 C̊LCO2 30kg

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

5

10

15

20

Ambient temp. ( C̊)

Tim

e (h

r.)

535 15 25 0301 20

SV of backup system –70 C̊LCO2 30kg

0 1 2 3 4 5 6 7 8 9 10Time (hr.)

Tem

p. (

˚C)

–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

0 1 2 3 4 5 6 7 8 9 10Time (hr.)

Ambient temp. ( C̊)Time (hr.) Time (hr.)

Ambient temp. ( C̊)Time (hr.) Time (hr.)

Ambient temp. ( C̊)Time (hr.) Time (hr.)

Tem

p. (

˚ C)

Tim

e (h

r.)

Tem

p. (

˚C)

Tem

p. (

˚ C)

Tim

e (h

r.)

Tem

p. (

˚C)

Tem

p. (

˚ C)

Tim

e (h

r.)

Tem

p. (

˚C)

Tem

p. (

˚ C)

–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

793

393

193

5

10

15

20

535 15 25 0301 200 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

5

10

15

20

535 15 25 0301 200 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

01020

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

01020

5 10 15 20 25 30 355

10

15

20

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

102030

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

SV of backup system –70 C̊LCO2 30kg

SV of backup system –70 C̊LCO2 30kg

SV of backup system –70 C̊LCO2 30kg

Performance data MDF-394

Performance data MDF-193

Performance data MDF-594

1280

762

795

1550

2010

500

53 770 38

861

105

1070

594

480

750

658

430

945

420

53 700 38

791

660

1400

1860

1120

530

105

945

53 800 38

891

520

MDF-393

762

1840795

2110

2570

500

77053 38

861

105

1070

Performance data MDF-794

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

Pull-down characteristics under no-load condition

Pull-up characteristics during power failure

Effect of ambient temp.on holding time of liquefied gas

5

10

15

20

Ambient temp. ( C̊)

Tim

e (h

r.)

535 15 25 0301 20

SV of backup system –70 C̊LCO2 30kg

0 1 2 3 4 5 6 7 8 9 10Time (hr.)

Tem

p. (

˚C)

–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

0 1 2 3 4 5 6 7 8 9 10Time (hr.)

Ambient temp. ( C̊)Time (hr.) Time (hr.)

Ambient temp. ( C̊)Time (hr.) Time (hr.)

Ambient temp. ( C̊)Time (hr.) Time (hr.)

Tem

p. (

˚ C)

Tim

e (h

r.)

Tem

p. (

˚C)

Tem

p. (

˚ C)

Tim

e (h

r.)

Tem

p. (

˚C)

Tem

p. (

˚ C)

Tim

e (h

r.)

Tem

p. (

˚C)

Tem

p. (

˚ C)

–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

793

393

193

5

10

15

20

535 15 25 0301 200 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

5

10

15

20

535 15 25 0301 200 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

01020

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

01020

5 10 15 20 25 30 355

10

15

20

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

0102030

0 1 2 3 4 5 6 7 8 9 10–90

–10

–30

–70

–20

–80

–50–60

–40

102030

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

Central air temp. in cabinetAmbient temp. 30 ˚C, no load

SV of backup system –70 C̊LCO2 30kg

SV of backup system –70 C̊LCO2 30kg

SV of backup system –70 C̊LCO2 30kg

MDF-794

MDF-794 MDF-594 MDF-394 MDF-193

Centre part of freezing room -86ºC. ambient temperature 30ºC

-50ºC to -86ºC

+ 50ºC to -100ºC (with optional MTR-85H recorder)

Performance

Type

Cooling performance

Control range

Recording range

52

-30ºC/-40ºC Plasma Freezer MDF-U5412

This Panasonic Plasma Freezer provides an ideal freezing environment forthe preservation of vaccines, blood plasma, test samples and specimens.

The user-friendly design includes a built-in door latch foreach of the double outer doors, and simple calibration ispossible via the control panel. This, coupled with a visualand audible alarm system, ensures that your samples areboth safe and secure, but also easy to access when youneed them.

Stable & Uniform Temperature Designl Double outer doorsl Full-height storage containers on each shelfl Cooling tubes under every shelfl Direct cooling system for stable temperature controll Fine-controllable refrigeration circuit with valve

Plasma Freezer

Options

Circular temperature chart recorder (-100ºC to +40ºC) MTR-G85Chart paper RP-G85 Ink pen PG-R Mounting kit MPR-S7

Communications Interface MTR-480

MDF-U5412-40ºC

482 LITRES

38

840

1802

1773

29

9198

692

692

260

800658

804

714772

589

1272

525 59

607

781

Dimensions

Performance data MDF-U5412

30

20

10

0

–10

–20

–30

–40

–500130 42 91 7 865

Time (h)

Tem

pera

ture

(˚C)

Pull-down characteristics

Ambient temp., 30˚C, no–load

Unit: mm

53

-30ºC/-40ºC Plasma Freezer MDF-U5412

Large Storage Capacityl 300ml FFP* bag x 280 pieces.

*Fresh Frozen Plasma

User Friendly Designl Built-in door latch for each doorl Easy calibration through the

control panel

Visual and Audible Alarm Systeml High & Low temperature alarm

l Power failure alarm with non-volatile memory back up

l Self-diagnostic system

Safety Functionl Remote alarm contactl Re-activating buzzer, lamp and

remote alarm contact (30min. afterbuzzer stops)

l Standard door lock and

independent padlock hasp doorlatches for extra security

l Remote monitoring by DataAcquisition System (Option)

l 1/7/30 days circular recorder(Option)

Environment friendlyl CFC-Free refrigerant and

insulation

38º41.38.60”N 9º12’.51.97”E

Torre de Belém, Lisbon.

Name: Fernando Gabriel

Location in our network:

Director Frilabo, Portugal.

Favourite place:

Torre de Belém, Lisbon.

This reminds all the Portuguese

the glorius days of the

"Descobertas"; Portuguese

maritime discoveries.

BIOMEDICAL NETWORK - ALB

ANI

A -

BIOMEDICAL NETWOR

K - POLAND -

BIOMEDICAL NETWOR

K -

FRANCE -

BIOMEDICAL NETWOR

K -

FINLAND -

BIOMEDICAL N

ETWORK - CROATIA -

BIOMEDICAL NETWORK - EST

ONIA -

BIOMEDICAL - FYR MACEDON

IA -

BIOMEDICAL NETWORK - ICE

LAN

D - BIOMEDICAL -BOSNIA HERZEG

OVNIA-

BIOMEDICAL NETWOR

K - CYPRUS- BIOMEDICAL NETWORK - B

ULGA

RIA -

BIOMEDICAL SERBIA & MONTE

NEG

RO

BIOMEDICAL NETWORK - LITH

UA

NIA -

BIOMEDICAL NETWORK - BELG

IUM-

BIOMEDICAL NETWOR

K - PORTUGAL-

54

In the biotechnology field, the freezers provide effective storage of enzymes for genetic research, as well as culturemedia, reagents and samples for testing. In the industrial field, they are ideal for ageing and temperature tests onelectronic components, precision devices, and compound resins. As a storage environment, with excellent safety features, easy operability, and a host of other features, thesefreezers offer unsurpassed reliability and functionality. If you are looking for precision temperature controlled storage equipment, look to Panasonic.

Panasonic’s MDF Series Biomedical freezers offer the outstanding reliability

and performance required in a wide variety of storage and research

applications. In the medical field, they provide effective storage of

life-saving blood supplies and vaccines, as well as samples for diagnosis.

Biomedical Freezers

-30ºC /-40ºC Freezers MDF-137 / MDF-237 / MDF-436 /

55º40.44.18”N 12º35’.39.50”E

Name: Poul Dam Hansen

Location in our network:

Sales Manager for DFA Instrument

s

Glostrup, Denmark.

Favourite place:

“Nyhavn” which is a colorful 17t

h

century waterfront in Copenhagen

,

because of its picturesque canal

s

with old historical ships and it

s

relaxed atmosphere both in winte

r

and summer times.

Nyhavn, Copenhagen

BIOMEDICAL NETWORK - DENMAR

K -

BIOMEDICAL NETWORK -

HUNGARY -

BIOMEDICAL NETWORK -

GERMANY-

BIOMEDICAL NETWORK -

AU

STRIA -

BIOMEDICAL NE

TW

ORK - SWEDEN -

BIOMEDICAL NETWORK NETHERLAN

DS

BIOMEDICAL NETWORK - U

K -

BIOMEDICAL NETWORK - NORWAY

-

BIOMEDICAL NETWORK - TURKE

Y-

BIOMEDICAL NETWORK -

ESPANA-

BIOMEDICAL NETWORK SWITZERLAN

D

BIOMEDICAL NETWORK - RUSS

IA -

BIOMEDICAL NETWORK - GREEC

E -

BIOMEDICAL NETWORK - MALTA -

BIOMEDICAL NETWORK -

ITALY-

55

Large-size 400 litre class.

l Digital temperature display asstandard feature.

l Large-capacity, economical size.

Small size suitable forpersonal use.l Digital temperature display

as standard feature.l Compact, personal size.

Versatile mid-size model.

l Digital temperature display as standard feature.

l Easy-to-use 200 litre mid-size model

MDF-237 MDF-436

807

670550

1265

1140

40 97

905 735

250

881

905

6879740 550

440

881

640

6879740 550

440

Front Front FrontSide Side Side

245 245 250715

250

715

250

790525

MDF-137

-30ºC /-40ºC Freezers MDF-137 / MDF-237 / MDF-436 / MDF-U334 / MDF-U443 / MDF-U5312 /MDF-U537D / MDF-U731M

Dimensions

Chest type Power to cope with frequent door openings

Unit: mm

Storage basketsMDF-137: MDF-13B2, set of two baskets

MDF-13B3, set of three baskets

MDF-237: MDF-13B2, set of two basketsMDF-13B3, set of three baskets

MDF-436: MDF-43B2, set of two basketsMDF-43B3, set of three baskets

MDF-U731M MDF-T07SC, set of two containers

MDF-137-30ºC

138 LITRES

MDF-237-30ºC

221 LITRES

MDF-436-35ºC

426 LITRES

56

-30ºC /-40ºC Freezers MDF-137 / MDF-237 / MDF-436 /

Easy-to-use, compactupright model.

l Microprocessor digitaltemperature display.

l Convenient storagedrawers.

Forced air circulation& auto defrost.

l High freezing powerincreasestemperatureuniformity.

l Auto defrost for easymaintenance.

Upright type Maximum capacity in minimum installation space

12 12

MDF-U334 MDF-U443

Dimensions

MDF-U334-30ºC

274 LITRES

MDF-U443-40ºC

426 LITRES

57

-30ºC /-40ºC Freezers MDF-137 / MDF-237 / MDF-436 /

Upright type Maximum capacity in minimum installation space Options

Circular temperature chart recorder (-100ºC to +40ºC) MTR-G85 (MDF-U334, U5312, U537D, U731M, 137, 237, 436)Chart paper RP-G85 Ink pen PG-R Mounting kit MPR-S7 (MDF-U5312, U537D (lower chamber), U731M )Mounting kit MDF-S740 (MDF-137, 237, 436)Mounting kit MDF-S740T (MDF- U334, U537D (upper chamber)) Temperature chart recorder (-100ºC to +50ºC) MTR-85H (MDF-U443)Chart paper RP-85Ink pen DF-38FPTemperature chart recorder (-40ºC to +14ºC) MTR-4015LH (MDF-U334, U5312, U537D, 137, 237, 436, U731M )Chart paper RP-40 Mounting kit MPR-S30 (MDF-U5312, U537D(lower chamber), U731M )Mounting kit MDF-S3040 (MDF-137, 237, 436)Set of 3 shelves MDF-T07ST (MDF-U731M)Set of 2 containers MDF-T07SC (MDF-U731M)Inventory racks see page 60

Communications Interface MTR-480 (Excluding MDF-U731M)

12MDF-U5312 MDF-U537D

Unit: mm

Large-capacity,economical, space-saving modell Top/bottom twin door

design prevents coldair from escaping.

l Individual freezercircuits for each ofthe five shelf levels.

MDF-U5312-30ºC

482 LITRES

MDF-U334 / MDF-U443 / MDF-U5312 /MDF-U537D / MDF-U731M

Independent top/bottomcontrol meets differingfreezer needsimultaneously.l Two independent freezer

chambers in one cabinet,with separate defrost andoperation.

l Individual freezer circuitsfor each of the five shelflevels.

MDF-U537D-30ºC

452 LITRES

58

-30ºC /-40ºC Freezers MDF-137 / MDF-237 / MDF-436 /

Enhanced Operationl Front-mounted display/control panel located at

convenient height.l Memory backup.l Temperature display.l Front access calibration for 7-day temperature recorder.l The control panel, alarm system and non-volatile

memory are the same for all models in the series.l Single electrical box makes servicing simpler.l The chamber temperature is displayed for five seconds

if BUZZER key is depressed during power failure alarm.l After a power outage, operation resumes at pre-outage

settings (non-volatile memory for temperature and alarmtemperature settings).

l Control panel can be reset to zero for validation.l Access ports.l Four casters and two adjustable feet.l Door locks

Recording Features (Optional)Recorder can be fitted in a convenient position that will notinterfere with installation. Choice of optional recorders*.l 7-day circular recorder (MTR-G85) and 32-day strip

recorder (MTR-4015LH) are available. (except MDF-U443)

l Temperature recorder with auto recharging batteryl Front access calibration for temperature recorder

* subject to model

Environment Friendlyl HFC refrigerant (non-CFC, non-HCFC refrigerant) is

environment-friendly and offers superb performance.

l Pre-coated metal body causes less environmental damage than conventional paint coating.

Safety Featuresl Alarm & recording system.l High/low temperature alarm (adjustable).l Power failure alarm. l Remote alarm contact.l Self diagnostics (“E” messages shown in red figures).l Breaker switch turns power off in event of over current

abnormality.

Balance hinge allows a free choice of opening angle (Chest type)To make this chest freezer easier to use, the balance hingekeeps the door open at whatever angle you choose. That means you have both hands free for work.

Lockable door latch for extra security (Upright type)By adding a commercially available lock, you can safeguardthe contents of the freezer and keep hazardous items outof harm’s way. (except MDF-U443)

Temperature Monitoring Features (Except MDF-U731M)l Unified remote monitoring system for Panasonic

Biomedical products (optional).

Features

Tem

per

atur

e (˚C

)

Pull-down characteristics under no-load condition

+40

+20

0

-20

-40

MDF-137 MDF-237 MDF-436 MDF-137 MDF-237 MDF-436

Time (Hr)

1 2 3 4 5 6

Tem

per

atur

e (˚C

)

Pull-up characteristics under no-load condition

+40

+20

0

-20

-40

Time (Hr)

1 2 3 4 5 6

Tem

per

atur

e (˚C

)

+40

+20

0

-20

-40

Time (Hr)

1 72 3 4 5 6 98

MDF-U5312

Tem

per

atur

e (˚C

)

+40

+20

0

-20

-40

Time (Hr)

1 72 3 4 5 6 98

MDF-U537D

Pull-down characteristicsPull-up characteristics during power failure

Top chamberBottom chamber

MDF-U334 MDF-U443

Tem

per

atur

e (˚C

)

+40

+20

0

-20

-40

Time (Hr)

1 72 3 4 5 6

Tem

per

atur

e (˚C

)

+40

+20

0

-20

-40

-60

Time (Hr)

1 72 3 4 5 6

Central air temp. in cabinetAmbient temp. 35˚C, No-load

Central air temp. in cabinetAmbient temp. 30˚C, No-load

Performance data MDF-137 / MDF-237 / MDF-436 / MDF-U334 / MDF-U443 / MDF-U5312 / MDF-U537D

-30ºC /-40ºC Freezers MDF-137 / MDF-237 / MDF-436 /

59

Performance data MDF-U731M

Pull-down characteristics

Pull-up characteristics

Cha

mb

er 1

/2H

Cen

tral

Air

tem

per

atur

e (˚C

)

Conditions: AT 35˚C, no load, measured at center of chamber

Time (hr.)

Cha

mb

er 1

/2H

Cen

tral

Air

tem

per

atur

e (˚C

)

Time (hr.)

–40

–20

0

20

–30

–10

10

30

0 1 6 92 1074 13 15

–40

0

–30

–20

30

20

–10

10

5 60 2 3 4 871

8

Pull-down characteristics

Pull-up characteristics

Cha

mb

er 1

/2H

Cen

tral

Air

tem

per

atur

e (˚C

)

Conditions: AT 35˚C, no load, measured at center of chamber

Time (hr.)

Cha

mb

er 1

/2H

Cen

tral

Air

tem

per

atur

e (˚C

)

Time (hr.)

–40

–20

0

20

–30

–10

10

30

0 1 6 92 1074 13 15

–40

0

–30

–20

30

20

–10

10

5 60 2 3 4 871

8

Pull-up characteristics duringpower failure

Pull-down characteristics underno-load condition

Large-capacity Biomedical freezer with direct coolingsystem and manual defrost

Stable temperature control The MDF-U731M provides precise and uniform storagetemperatures regardless of ambient conditions throughmicroprocessor temperature control. Energy-saving operationThe specially designed compressor results in an energy-saving medical freezer with superior cooling and quietoperation. Improved security Standard door lock and independent padlock ensure

extra security. (*Padlock is not supplied) Sturdy cabinet construction with superior insulation The integral foamed cabinet structure is extra strong andprevents cold air loss. Manual defrost Manual defrost freezers provide stable temperaturecontrol and do not exhibit the transient temperatureincreases that can be associated with auto-defrost typefreezers. The MDF-U731M is therefore ideal for storingyour important, temperature-sensitive samples. Movable shelves Movable wire shelves allow free position adjustment.

MDF-U731M-20ºC / -30ºC690 LITRES

MDF-U334 / MDF-U443 / MDF-U5312 /MDF-U537D / MDF-U731M

650

770

1491

1520

830

1955

89700

362.

536

2.5

362.

5

10

Dimensions MDF-U731M

Unit: mm

Set of 2 containersMDF-T07SC

60

Inventory Racks

Whether your storage unit is an uprightfreezer, a chest freezer or even a liquidNitrogen freezer, an organized freezer willprovide you:l Time efficiency because you can locate,

retrieve and replace your samples easilyand quickly

l Cost efficiency because organizedsamples and cell lines might reduce thenumber of freezers

l Safety because your samples are betterprotected

Panasonic’s racks are made of stainless steelor anodized aluminum. The aluminum racksare very light, yet sturdy and corrosion free.

How to organize your low temperature freezer

Organizing the spaces in your freezer can helpyou to make your work more efficient. Both cost- and time savings will be the result of goodsample management. But it is not onlyefficiency that will be influenced positively, youwill also decrease the risk of damaging yoursamples with the right racks. This is a fact,whether you store stem cell, cord blood, bonemarrow or any other type of cell or tissuesamples.

53º28.43.67”N 6º09’.58.77”E

Schiermonnikoog, the Netherlands

Name: Ton Schipperheijn

Location in our network:

Marketing Manager

Panasonic Biomedical Sales

Europe B.V., The Netherands.

Favourite place:

The small island of

Schiermonnikoog, because it’s

peaceful, and has a

breathtaking scenery.

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

61

Inventory Racks

Since this can be a challenge, we give you an overview of a selectionof popular freezers, in combination with a variety of racks in thespecification section on page 168. There you will find the mostcommon used racks. If you are looking for another more economical/practical way to useyour limited available freezer capacity, or just need a special sizedrack, please contact us.

How to select the correct rack for your low temperature freezer

Standard square rack 3101A-100Sconfiguration 1500AB

Racks for all liquid Nitrogen freezerapplications see: www.panasoniccryogenic.com

62

With the growing emphasis on proper storage of laboratoryrefrigerated products the market requires state-of-the-artequipment to provide unyielding parameter control. In order toachieve this goal Panasonic totally redesigned therefrigerator/freezer.

l One unit with dual temperature zonel Superior cooling performancel Quiet operationl Various alarm and safety devices

Pharmaceutical Refrigerator with Freezer

LED display for easy-to-read temperatureand alarms

Triple pane window forviewing (MPR-414F)

Center pillarless design for easy access

Direct cooling freezercompartment for stabletemperature

Optional Drawers(MPR-41R)

Options

Temperature chart recorder MTR-G3504(-10ºC to +40ºC and -60ºC to +40ºC) Chart paper RP-G3504Ink pen PG-RBMounting kit MPR-S7Drawers for the bottom left compartment (MPR-414F only) MPR-41R

Communications Interface MTR-480

51º13.00.00”N 2º54.00.00”E

Name: Herman Geldof

Location in our network:

Specialist in Belgium since

he knows all the technical

details from the Panasonic Biome

-

dical products at TCPS, Belgium

Favourite place:

Belgium coast Belgian coast

BIOMEDICAL NETWORK -

ALBANIA -

BIOMEDICAL NE

TW

ORK - POLAND -

BIOMEDICAL NE

TW

ORK - FRANCE -

BIOMEDICAL NE

TW

ORK - FINLAND -

BIOMEDIC

AL N ETWORK - CROATIA -

BIOMEDICAL NETWORK - E

STONIA -

BIOMEDICAL - FYR MAC

EDO

NIA -

BIOMEDICAL NETWORK - I

CELAND -

BIOMEDICAL -BOSNIA HERZ

EGOVNIA-

BIOMEDICAL NE

TW

ORK - CYPRUS-

BIOMEDICAL NETWORK -

BU

LGARIA -

BIOMEDICAL SERBIA & MO

NTENEGRO

BIOMEDICAL NETWORK - L

ITHUANIA - BIOMEDICAL NETWORK

- BEL

GIUM-

BIOMEDICAL NET

WO

RK - PORTUGAL-

Refrigerator with Freezer MPR-414F / MPR-215F

Envirocenter

n l

n l

n l

n l

n l

n l

n l

n l

n l

n l

n l

n l

n l

n l

n l

n l

The benefits of Enviro-center(compared to typical domestic refrigerators)

n Necessary function, construction or performance for preservation of reagents and pharmaceuticals

l Yess Some models are Yest NO

Domesticrefrigerator

t

t

t

Max/Mid/Min

-18°C

t

t

t

s

t

s

t

t

t

t

l

63

Stored product integrity assured by:l Microprocessor control system that provides

accurate temperature.l Fan convection system in refrigerator employs

ducting and plenums that provide uniformtemperature throughout the cabinet.

l Unique refrigerator defrost system minimisestemperature variations during defrost cycles byactivating after each compressor cycle, thusminimizing the duration of the defrost cycle.

l Secondary temperature deviation safety devicethat prevents excessive warm-up or cooling.

l Open door indicator light with 15 min. delayedaudible alarm.

l Low/high temperature audible and visual alarmsand remote alarm.

l Door locks.

Energy efficient and environmentally friendlyoperation:l Two specially designed low wattage/ energy

consuming hermetic compressors.l Four door design reduces air loss on entry and

makes efficient use of space in front of the unit(MPR-414F).

l Hot gas heated mullions prevent condensation,icing and subsequent loss of gasket sealingefficiency.

l Very quiet operation.l CFC-free foamed-in-place insulation.l HCFC/CFC-free refrigerant.l Efficient use of material is demonstrated by the

low overall weight 126 kg (MPR-414F).

MPR-414F340 LITRES

+82 LITRES

Reliable temp. control not Affected by ambient temp.Digital display of chamberTemperaturePrecise temperature settingof chamberVariable temp. control ofRefrigerator (2°C to 14°C )Variable temp. control ofFreezer (-20°C to -30°C)Separate operation ofRefrigerator and freezerWindows for viewingRacks (SUS-304, MPR-41R)Monitoring hole/portTemperature recorder (option)Door ajar alarmHigh/low alarm andOverheating protectionRemote alarm terminalSet temp. deviation protectionSelf diagnostic functionCondensate evaporator

Refrigerator with Freezer MPR-414F / MPR-215F

64

Refrigerator with Freezer MPR-414F / MPR-215F

Design features which enhance user operation:l Two full width and three half width shelves provide

1.23m2 (13.5ft2) of refrigerator storage with 200mm (8”)height clearance. Shelves adjustable on 100mm (4”)centers (MPR-414F)

l One freezer shelf permits two levels of storage on0.2m2 (2.6ft2) of shelf area. (MPR-414F)

l The top refrigerated section has a pillarless design foreasy access and triple pane windows for viewing.

(MPR-414F)l Small radius door design.l Interior incandescent light.l 30mm access port for the refrigerator and freezer

sections.

Field support and future serviceability is assured by:l Microprocessor self-diagnosing electronics.l The use of safe HCFC/CFC-free refrigerant.

LED display for easy-to-read temperature and alarms

Double panewindow for viewing

Direct cooling freezer compartment for stable temperature

Performance data MPR-414F

MPR-215F176 LITRES

+39 LITRES

65

Refrigerator with Freezer MPR-414F / MPR-215F

Performance data MPR-414F

Temperature alarm

Overheating protection

Memory back-up function

Door Ajar

Self-diagnostic function

Key lock switch

MPR-414F MPR-215F

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Yes Yes

Alarm and safety functions

MDF-414F Effective Temperaturecapacity range

Refrigerator 340 litres 2ºC to 14ºC

Freezer 82 litres -20ºC to -30ºCambient temp: 30ºC

Dimensions

MPR-414FSMPR-414F

60054060

495

440

33

315

100

574

495

446

234

132.

5

1805

800720

340

1425

350

586

763

337 317

6911

7

245

115

60054060

495

440

33

315

100

574

495

446

234

132.

5

1805

800720

340

1425

350

586

763

500 200

337 317

6911

7

245

115

28 28

214F

1790

123

540455

750

250

420

82

50057450

917

267

465

315

155

557

60

(Unit: mm)

Refrigerator

Freezer

Power cord position

Power cord position

Access port

Power cord position

Dimensions

MPR-414FSMPR-414F

60054060

495

440

33

315

100

574

495

446

234

132.

5

1805

800720

340

1425

350

586

763

337 317

6911

7

245

115

60054060

495

440

33

315

100

574

495

446

234

132.

5

1805

800720

340

1425

350

586

763

500 200

337 317

6911

7

245

115

28 28

214F

1790

123

540455

750

250

420

82

50057450

917

267

465

315

155

557

60

(Unit: mm)

Refrigerator

Freezer

Power cord position

Power cord position

Access port

Power cord position

Refrigerator

Freezer

MPR-414FMPR-215F

Name: Mikkel Holm

Location in our network:

Managing Director,

Buch & Holm, Denmark.

favourite place:

“The Little Mermaid” placed

by the sea in Copenhagen.

Copenhagen, Denmark

BIOMEDICAL NETWORK -

DENMARK -

BIOMEDICAL NET

WORK - HUNGARY -

BIOMEDICAL NET

WORK - GERMANY- BIOMEDICAL NET

WORK - AUSTRIA -

BIOMEDIC

AL N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NE

THERLANDS

BIOMEDICAL NETWORK

- UK -

BIOMEDICAL NETWORK - N

ORWAY -

BIOMEDICAL NETWORK -

TURKEY-

BIOMEDICAL NE

TW

ORK - ESPANA-

BIOMEDICAL NETWORK SW

ITZERLAND

BIOMEDICAL NETWORK -

RUSSIA -

BIOMEDICAL NETWORK - G

REECE -

BIOMEDICAL NETWORK -

MALTA -

BIOMEDICAL N

ETWORK - ITALY-

66

Refrigerators MPR-1411 / MPR-1411R / MPR-721 / MPR-721R

Stable and reliable refrigerated environment for exacting laboratory requirements.

It is common knowledge that product should be storedin stable conditions below ambient temperature.Domestic refrigerators are capable of storage at +4°C,but they suffer from the following drawbacks:1. Temperature varies every time the door is opened2. Temperature rises during defrosting3. Cabinet temperature is easily affected by ambient

temperature, with the risk of contents freezing ifambient drops below 0°C

4. Temperature setting by dial is inaccurate (no digitaltemperature indication)

Panasonic has built solutions for all these problems into

its medical refrigerators, which have been well receivedin hospitals, laboratories and research facilities aroundthe world.Main Features:1. Rapid temperature recovery after door opening.2. Stable, uniform, and controlled cabinet temperature

is unaffected by ambient temperature.3. Cycle defrost with heater allows defrosting without

increases in cabinet temperature.4. Standard alarm and safety features prevent irregular

temperature fluctuations in cabinet.

Large capacity enviro-centers

Environmental laboratory. Wide temperature range 2°C to 23°C (ambient temp. 0°C to 35°C).

55º40.44.18”N 12º35’.39.50”E

67

Refrigerators MPR-1411 / MPR-1411R / MPR-721 / MPR-721R

Adjustable shelves (MPR-721/1411)The shelves can be arranged to accommodate tallapparatus such as fraction collectors. These shelves aredeep enough and strong enough (50kg load for the MPR-721, 40kg for the MPR-1411) to hold most apparatus.

Drawer type (MPR-721R/1411R)The “R” models are fitted with pull-out drawers. With aprofile of 100mm and 530mm front to back, these drawersare deep enough to hold large bottles or reagent kits. Theyalso allow convenient, space-efficient storage andmanagement of patient medications and other items.

The MPR-721R is shipped with five drawers, while theMPR-1411R is shipped with ten drawers, five in each half ofthe cabinet.

Temperature Stability Panasonic’s temperature control system with thermistormonitor and microprocessor control reliably maintains cabinettemperature at the set level and is unaffected by ambienttemperature. Forced air circulation ensures that the cabinettemperature returns to the set point quickly after dooropenings and remains uniform throughout the cabinet.

MPR-14111.364 LITRES

MPR-1411R1.359 LITRES

Options

Temperature chart recorder (-6˚C to +20˚C) MTR-0621LHChart paper RP-06Mounting kit MPR-S30

Circular Temperature chart recorder (-10˚C to +40˚C) MTR-G04Chart paper RP-G04Ink pen PG-RMounting kit MPR-S7

Exterior Power MPR-48Bfailure alarm (MPR-721 only)

Communications Interface MTR-480Mounting bracket MPR-48B

n Adjustable shelves and wide range set point for varyinglaboratory applications including chromatography andpharmaceutical storage.

n Drawers for convenient storage.

68

Refrigerators MPR-1411 / MPR-1411R / MPR-721 / MPR-721R

n Movable wire shelves for test apparatus andstorage flexibility.

n Pull-out drawers for convenient filing of storageitems.

MPR-1411 MPR-1411R MPR-721

Dimensions

MPR-721684 LITRES

MPR-721R671 LITRES

69

Refrigerators MPR-1411 / MPR-1411R / MPR-721 / MPR-721R

Speedy & Powerful refrigerationTo cope with frequent door openings,Enviro-Centers are equipped with powerful,hermetically sealed compressors. Thesepurpose-built compressors ensure superiorpull-down characteristics and precisetemperature control.

Easy-to-manage layoutThe interior layout flexibility of Enviro-Centers makes them ideal for runningexperiments that require stable coolconditions, as well as storage.

Standard alarm & safety features Enviro-Centers are fitted with buzzers andflashing lights to warn of high and lowtemperature problems. In the event of anirregular rise in cabinet temperature, theheater automatically shuts off and forced aircirculation brings the temperature down.Door locks are fitted to safeguard valuablecontents.

Large CapacityWith a modular width of 770mm the MPR-721 offers a capacity of 684 litres(MPR-721R: 671 litres), while the 1440mmwide MPR-1411 offers a capacity of 1370litres (MPR-1411R: 1365 litres). The interioris spacious enough to accommodatecolumn chromatography apparatus or largevolumes of reagents, test samples andbiologicals.

Wide temperature range With a temperature range of 2°C to 23°C,Enviro-Centers are ideally suited for teststhat require a stable, cool temperature.

Large fansThe 120mm diameter fan ensures an eventemperature throughout the cabinet (MPR-1411/R models have a double flowsystem with two fans). Heat spots frompowered test apparatus are minimized andpull-down characteristics after dooropenings are outstanding.

HFC Refrigerant & CFC free insulationPanasonic biomedical equipment isdesigned for low environmental impact.The MPR-721 and 1411 series use HFCrefrigerant, and the foamed-in-placeinsulation is also CFC free.

Cycle defrost In the 5°C range, frost build-up on theevaporator is inevitable. This can affect theperformance of the heat exchanger.Panasonic has solved this problem with acycle defrost and evaporator temperaturesensor system. This system runsautomatically, so there is no need to turn offthe power for defrosting. Temperature riseduring defrost is minimal. The evaporationheater also doubles as protection againstdrops in cabinet temperature caused by alow ambient temperature.

Other features (MPR-721/721R)New concept features have been added tothe MPR-721 and 721R. The filterlesscondenser cuts down on cleaningmaintenance. All glass doors now include aprotective film to prevent shattering in theevent of accidental collisions.

User friendly design and double functiondoor Easy to read and operate control panelfeaturing a full array of alarm and safetyfunctions. Access ports are standard toallow access for power cords. Aestheticallyattractive exterior colour blends well in mostlab colour schemes. The “catch-free”rounded corners are safe and attractive.Doors open smoothly and closeautomatically. Some laboratory refrigeratorshave solid doors for temperature stability,while others have glass doors for easyviewing. Panasonic Enviro-Centers give you the bestof both versions. The broad, solid frameswith effective gaskets ensure excellenttemperature stability, and the double-paneglass windows offer an excellent view of theinterior without compromising temperaturestability.

Performance data MPR-721MPR-721R

Performance data MPR-1411MPR-1411R

MPR-721R

700

600

500

400

300

200

100

0

35

30

25

20

15

10

5

0

40

30

20

10

0

-10

0 5 10

23ºC

15 20 25 30 35

0

0 60 120 180 240

50 100 150 200 250 300

Time (min.)

Time (min.)

Ambient temperature (°C)

Tem

p. (

°C)

Tem

p. i

n ch

amb

er (°

C)

Insi

de

ther

mal

load

(W)

Air temp. at centre of chamber Ambient temp. 35°C

Initial conditions: chamber stable at 2°C

Air temp. at centre of chamber Ambient temp. 30°C

Power source: Single 100V 50Hz

Air temp. at centre of chamber Ambient temp. 35°C

MPR-1411 Pull-down characteristics (no-load)

MPR-1411 Test of permissible inside thermal load

MPR-1411 Pull-up characteristics (no-load)

10ºC

5ºC

2ºC

MPR-721 Permissible inside thermal load

0 5 10 15 20 25 30 35

700

600

500

400

300

200

100

0

Insi

de

ther

mal

load

(W)

Ambient temperature (˚C)

23˚C10˚C

5˚C2˚C

Temperature pull-up characteristics

Temperature pull-down characteristics

0 1 2 3 4 5 6 7 8

40

10

20

30

0

Tem

per

atur

e (˚C

)

Time (hour)

700

600

500

400

300

200

100

0

35

30

25

20

15

10

5

0

40

30

20

10

0

-10

0 5 10

23ºC

15 20 25 30 35

0

0 60 120 180 240

50 100 150 200 250 300

Time (min.)

Time (min.)

Ambient temperature (°C)

Tem

p. (

°C)

Tem

p. i

n ch

amb

er (°

C)

Insi

de

ther

mal

load

(W)

Air temp. at centre of chamber Ambient temp. 35°C

Initial conditions: chamber stable at 2°C

Air temp. at centre of chamber Ambient temp. 30°C

Power source: Single 100V 50Hz

Air temp. at centre of chamber Ambient temp. 35°C

MPR-1411 Pull-down characteristics (no-load)

MPR-1411 Test of permissible inside thermal load

MPR-1411 Pull-up characteristics (no-load)

10ºC

5ºC

2ºC

MPR-721 Permissible inside thermal load

0 5 10 15 20 25 30 35

700

600

500

400

300

200

100

0

Insi

de

ther

mal

load

(W)

Ambient temperature (˚C)

23˚C10˚C

5˚C2˚C

Temperature pull-up characteristics

Temperature pull-down characteristics

0 1 2 3 4 5 6 7 8

40

10

20

30

0

Tem

per

atur

e (˚C

)

Time (hour)

700

600

500

400

300

200

100

0

35

30

25

20

15

10

5

0

40

30

20

10

0

-10

0 5 10

23ºC

15 20 25 30 35

0

0 60 120 180 240

50 100 150 200 250 300

Time (min.)

Time (min.)

Ambient temperature (°C)

Tem

p. (

°C)

Tem

p. i

n ch

amb

er (°

C)

Insi

de

ther

mal

load

(W)

Air temp. at centre of chamber Ambient temp. 35°C

Initial conditions: chamber stable at 2°C

Air temp. at centre of chamber Ambient temp. 30°C

Power source: Single 100V 50Hz

Air temp. at centre of chamber Ambient temp. 35°C

MPR-1411 Pull-down characteristics (no-load)

MPR-1411 Test of permissible inside thermal load

MPR-1411 Pull-up characteristics (no-load)

10ºC

5ºC

2ºC

MPR-721 Permissible inside thermal load

0 5 10 15 20 25 30 35

700

600

500

400

300

200

100

0

Insi

de

ther

mal

load

(W)

Ambient temperature (˚C)

23˚C10˚C

5˚C2˚C

Temperature pull-up characteristics

Temperature pull-down characteristics

0 1 2 3 4 5 6 7 8

40

10

20

30

0

Tem

per

atur

e (˚C

)

Time (hour)

Unit: mm

Model Shelves/DrawersMPR-1411 8 wire shelvesMPR-1411R 10 drawersMPR-721 4 wire shelvesMPR-721R 5 drawers

70

Refrigerators MPR-1014 / MPR-1014R / MPR-514 / MPR-514R

Several factors are important to assure the quality of pharmaceuticals, samplesand reagents. These are storage temperature, expiry date, exposure to ultravioletlight and humidity. Of these the most important is storage temperature. If thetemperature is too high, chemical changes can occur which affect the quality ofthe materials. If the temperature is too low, there is a risk of structural changesbrought about by freezing. Narrow and uniform temperature control withoutregard to ambient conditions is very important. Don’t compromise your results!

Spacious capacity meets versatile requirements of pharmaceutical refrigeration, from small-variety packages to large-variety packages.

Stable and reliable environment control – the key to high-precision performance for exacting storage orresearch requirements

Name: Smadar Shenkevich

Location in our network:

Sales Manager

Yagev Ltd., Israël.

Favourite place:

Rosh Hanikrah.

BIOMEDICAL NETWORK - L

ISB

ON -

BIOMEDICAL NETWOR

K - LATVIA - BIOMEDICAL NETW

ORK - ISRAEL -

BIOMEDICA

L N

ETWORK - CROATIA -

BIOMEDICAL NETWORK - ES

TO

NIA -

BIOMEDICAL - CZECH REPU

BLI

C -

BIOMEDICAL NETWORK - IC

ELA

ND -

BIOMEDICAL -BOSNIA HERZE

GOVNIA-

BIOMEDICAL NETWORK

- CYPRUS-

BIOMEDICAL NETWORK - BU

LGARIA -

BIOMEDICAL SERBIA & MONT

ENEGRO

BIOMEDICAL NETWORK - GE

ORGIA -

BIOMEDICAL NETWORK - FI

NLAND -

BIOMEDICAL NETWORK

- SLOVENIA-

MPR-1014R1.029 LITRES

Equipped with sliding racks.2°C to 14°C

(Ambient temperaturefrom -5°C to +35°C)

71

Refrigerators MPR-1014 / MPR-1014R / MPR-514 / MPR-514R

Uniform storage unaffected byambient temperature Microprocessor controlledAn electronic sensor accuratelymonitors chamber temperature andfeeds the information to themicroprocessor for precise control atpreset temperature. Fans ensuregentle air circulation to provideuniform top to bottom temperaturecontrol after frequent door openings.Panasonic’s easily calibrated, reliableand stable controls make validationeasier.

Remarkable cooling efficiencyA highly efficient hermetic compressor,specially designed and developed by

Panasonic, is utilized to providepowerful and rapid cooling to maintainproper temperature level.

Ergonomic designThe ergonomic design of the MPRseries refrigerators provides a clearview of stored items through the largeframed windows. The slim profileallows for easy-reach retrieval of yourproducts. Users can choose from twotypes to suit their needs; one with allwire shelves or one with sliding rackson one side.

Double-sensor temperaturemanagementThe double-sensor control system with

alarm-exclusive sensor added to thetemperature control sensor alwaysmonitors the precise chambertemperature.

Safety is a Panasonic standardEven the best designed refrigeratormust be prepared for the unexpected.l Cabinet construction

View Window design with protectivefilm to prevent shattered glass fromscattering onto the floor. Alsofeatures key locked doors.

l Control safety devicesAudible and flashing LED visualalarms alert you to the unlikelyevent of either a high or lowtemperature condition. An

Rosh HaNikrah, Israël

33º05.08.59”N 35º06.42.30”E

PlenumsPanasonic’s plenumdesign features uniformcold air flow distributionthroughout the chamberto ensure temperatureuniformity - essential forvalidated storagerequirements.

MPR-10141.033 LITRES

Equipped with wire shelves

1790

900800 (inside)

158(duct)

658600 508

150 50

466

1202

122

440

1200 13

50

415

465

1300

1085

300158

(duct)158

(duct)

1700 (inside)1800

1790

1300

465

415

5013

50

1200

440

122

1202

466

5015050600

1078

300

6599

Front elevation End section noitces dnEnoitavele tnorF

72

Refrigerators MPR-1014 / MPR-1014R / MPR-514 / MPR-514R

Time (Hr)

10

5

0

-5

-10

40

35

30

25

20

15

10

5

0

10

5

0

-5

-10

0 0 8 16 2410 20 30

-10 0 10 20 30

Ambient Temperature (°C)

Ambient Temperature (°C)

Ambient Temperature (ºC)

Ambient Temperature (ºC)

Insi

de

Tem

per

atur

e (°

C)

Inside Temperature (ºC)

Insi

de

Tem

per

atur

e (°

C)

Upper limit of cycle

Center of Cabinet

Lower limit of cycle

Upper limit of cycle

Center of Cabinet

Lower limit of cycle

Conventional Refrigerator

Uniform Storage Temperature-ambient Temperature

SANYO MPR

Uniform Storage Temperature-Cycle Defrost

SANYO MPR

Conventional Refrigerator

Time (Hr)

40

35

30

25

20

15

10

5

08 16 24

Temp. rise during defrost cycle

MPR-514/MPR-514R MPR-1014/MPR-1014R

DimensionsUnit: mm

Options

Temperature chart recorder (-6˚C to +20˚C) MTR-0621LHChart paper RP-06Mounting kit MPR-S30 Circular Temperature chart recorder (-10˚C to +40˚C) MTR-G04Chart paper RP-G04Ink pen PG-RMounting kit MPR-S7External mounting Power Failure Alarm MPR-48B

Communications Interface MTR-480Mounting bracket MPR-48B

over-shooting prevention circuit automatically switchesoff the fan motor or heater, if the inside temperature risesabnormally.

l Comprehensive alarmsIn addition to Low/High temperature alarms and door ajaralarm, power failure alarm can be installed as an option.Remote alarm terminal is also provided as standard.

Worry-free cycle defrosting systemWith Panasonic’s cycle defrost system, defrosting isperformed automatically during compressor “off” cycles,

and by sensing frost levels. This way defrosting is performedonly when required, further protecting the contents againstunnecessary temperature rise. The defrosting heater alsoacts as an emergency heat source to prevent samples fromfreezing.

HFC refrigerant & HCFC-free insulationPanasonic biomedical equipment is designed for lowenvironmental impact. The MPR-514 and 1014 series useHFC refrigerant and the foamed-in-place insulation is HCFC free.

Performance data MPR-1014 / MPR-1014R / MPR-514 / MPR-514R

Refrigerators MPR-1014 / MPR-1014R / MPR-514 / MPR-514R

73

MPR-514489 LITRES

MPR-514R486 LITRES

Butrinti, Albania

39º45.51.00”N 20º01’.59.00”E

74

Panasonic pharmaceutical refrigerators – safe,worry-free cold storage of valuable medicalsupplies.To ensure quality, safety and effectiveness of vital

medical supplies, Panasonic medical refrigeratorsfeature precisely regulated cooling systems thatmaintain a delicate temperature balance under a widerange of conditions. For many years, Panasonic has

Medical refrigerators for reliable storage of pharmaceutical and medicalsupplies. For a versatile range of storage applications – compact and large-capacity medical refrigerators.

Name: Robert Nikolla

Location in our network:

General Manager of Panasonic's

partner in Albania.

Favourite place:

Butrinti, Albania because the

city of Butrinti is one of the

fragments which form the fabric

of Albania's ancient cultural

landscape.

BIOMEDICAL NETWORK -

ALBANIA -

BIOMEDICAL NE

TW

ORK - POLAND -

BIOMEDICAL NE

TW

ORK - FRANCE -

BIOMEDICAL NE

TW

ORK - FINLAND -

BIOMEDIC

AL N ETWORK - CROATIA -

BIOMEDICAL NETWORK - E

STONIA - BIOMEDICAL - FYR M

ACEDO

NIA -

BIOMEDICAL NETWORK - I

CELAND -

BIOMEDICAL -BOSNIA HERZ

EGOVNIA-

BIOMEDICAL NE

TW

ORK - CYPRUS-

BIOMEDICAL NETWORK -

BU

LGARIA -

BIOMEDICAL SERBIA & MO

NTENEGRO

BIOMEDICAL NETWORK - L

ITHUANIA - BIOMEDICAL NETWORK

- BEL

GIUM-

BIOMEDICAL NET

WO

RK - PORTUGAL-

Refrigerators MPR-161D(H) / MPR-311D(H)

Safe, worry-free cold storage of valuable medical supplies

75

provided equipment for medical supply storage andtemperature control to hospitals and pharmaciesthroughout the world. Now, utilizing this accumulatedexperience plus valuable feedback from the medicalcommunity, Panasonic has developed the Medi-Cool lineof medical refrigerators, each of which is equipped withadvanced cooling and electronic technology to providethe ideal temperature for the perfect preservation of awide range of medical supplies.

Remarkable Cooling EfficiencyTaking into consideration that pharmaceutical refrigeratorsmust be opened frequently, a highly efficient hermetic

compressor, specially designed and developed byPanasonic, is utilized in each model of the Medi-Coolseries. The hermetic compressor provides powerful, immediatecooling which is effective in maintaining the insidetemperature at a constant level.

Effective Temperature Control1. Electronic Temperature Control SystemA thermistor sensor monitors temperature inside thechamber and microprocessor and electronic temperaturecontrol ensure that the set temperature is maintained.Even if the door is opened and closed frequently, the

Options

Temperature chart recorder (-6˚C to +20˚C) MTR-0621LHChart paper RP-06

MPR-161D(H)158 LITRES

MPR-311D(H)340 LITRES

Refrigerators MPR-161D(H) / MPR-311D(H)

Safe, worry-free cold storage of valuable medical supplies

76

Refrigerators MPR-161D(H) / MPR-311D(H)

circulation fan ensures rapid temperature adjustmentto provide a highly reliable, stable preservationenvironment that is not affected by ambienttemperature. The MPR-161D(H) and 311D(H) have adigital temperature display for easy confirmation.

2. Fan-Forced Air CirculationThe temperature stays even throughout the inside ofthe refrigerator with the fan-forced air circulationsystem. No matter how the load is distributed, everycorner of the unit is immediately cooled with nonoticeable variation in temperature apparent inside thecabinet.

3. Cyclical Defrosting SystemDuring normal operation, the cyclical defrostingsystem permits defrosting to take place withoutincreasing the temperature inside the cabinet.

Equipped with Digital Temperature DisplayEasy-to-read digital temperature display provides at-a-glance confirmation of the current operatingtemperature. To simplify temperature control,temperature readings are displayed in graduations of1ºC for temperatures ranging from 0ºC to 15ºC.

Easy-to-Use Doors1. Double-Paned Glass with Heat-Reflective FilmThe refrigerator doors, constructed of double-panedglass with heat-reflective film, allow easy loading and

unloading of medical supplies while preventingultraviolet rays, which may damage the stored items,from entering the unit. Panasonic’s unique heat-reflective film blocks the passage of radiant heat raysthrough the glass panels and keeps the insidetemperature from being adversely affected by excessiveamounts of heat.

2. Door Open AlarmWhen the door is opened, the Door Open indicatorlamp lights automatically. After approx. 30 seconds abuzzer alarm will sound if the door has not beenclosed. When you want to keep the door open for morethan 30 seconds, you can deactivate the alarm via thebuzzer switch provided.

Abnormal Temperature Alarm and Safety Devices1. Abnormal Temperature AlarmIf the inside temperature suddenly descends to below 0ºC or rises to above 15ºC, the buzzersounds an alarm. Simultaneously, the digitaltemperature display flashes.

2. Abnormal Temperature Safety DeviceIf the internal temperature reaches below –2ºC

or above 20ºC (approx.), the low and high-temperature safety devices prevent the contents ofthe refrigerator from freezing or the temperaturefrom rising abnormally while visible and audiblealarms are activated.

77

Refrigerators MPR-161D(H) / MPR-311D(H)

MPR-311D(H)MPR-161D(H)

Dimensions

Unit: mm

10

8

6

5

4

2

-10

15

10

5

0

-5

-10

0 10 20 30

-10 0 10 20 30

8 16 24

Ambient temp. (ºC)

Ambient temp. (ºC)

Insi

de

tem

p.

(ºC

)

Inside temp.

Temp. rise during defrosting cycle

Insi

de

tem

p.

(ºC

)

Temperature at centerof cabinet

Temperature at centerof cabinet

8 16 24

Conventional home refrigerator

Conventional refrigerators

Comparison with conventional refrigerators

Relationship between the inside temperature

and ambient temperature

Time (Hr)

Time (Hr)

(ºC)

35

20

15

10

5

0

(ºC)

35

20

15

10

5

0

Ambient temp. (ºC)

Ambient temp. (ºC)

Panasonic MPR

Panasonic MPR

10

8

6

5

4

2

-10

15

10

5

0

-5

-10

0 10 20 30

-10 0 10 20 30

8 16 24

Ambient temp. (ºC)

Ambient temp. (ºC)

Insi

de

tem

p.

(ºC

)

Inside temp.

Temp. rise during defrosting cycleIn

sid

e te

mp

. (º

C)

Temperature at centerof cabinet

Temperature at centerof cabinet

8 16 24

Conventional home refrigerator

Conventional refrigerators

Comparison with conventional refrigerators

Relationship between the inside temperature

and ambient temperature

Time (Hr)

Time (Hr)

(ºC)

35

20

15

10

5

0

(ºC)

35

20

15

10

5

0

Ambient temp. (ºC)

Ambient temp. (ºC)

Panasonic MPR

Panasonic MPR

Performance data MPR-161D(H) / MPR-311D(H)

n Rigid polyurethane foam insulationacts to keep cold air inside the unitand effectively protects against theintrusion of warm air.

n Chemical-resistant interior surfaceof the cabinet ensures reliableservice for many years of use.

n Less installation area is requiredwith the use of 2 easy-open slidingdoors.

10

8

6

5

4

2

-10

15

10

5

0

-5

-10

0 10 20 30

-10 0 10 20 30

8 16 24

Ambient temp. (ºC)

Ambient temp. (ºC)

Insi

de

tem

p.

(ºC

)

Inside temp.

Temp. rise during defrosting cycle

Insi

de

tem

p.

(ºC

)

Temperature at centerof cabinet

Temperature at centerof cabinet

8 16 24

Conventional home refrigerator

Conventional refrigerators

Comparison with conventional refrigerators

Relationship between the inside temperature

and ambient temperature

Time (Hr)

Time (Hr)

(ºC)

35

20

15

10

5

0

(ºC)

35

20

15

10

5

0

Ambient temp. (ºC)

Ambient temp. (ºC)

Panasonic MPR

Panasonic MPR

78

Refrigerators MBR-305GR / MBR-704GR / MBR-1405GR / MBR-107D(H) / MBR-506D(H)

Name: Carole Coupez

Location in our network:

Sales Representative Panasonic

Biomedical Sales Europe B.V.,

France

Favourite place:

Boulevard Haussmann because it

is the best shopping place in

Europe.

Paris, France

BIOMEDICAL NETWORK -

ALBANIA -

BIOMEDICAL NE

TW

ORK - POLAND -

BIOMEDICAL NE

TW

ORK - FRANCE -

BIOMEDICAL NE

TW

ORK - FINLAND -

BIOMEDIC

AL N ETWORK - CROATIA -

BIOMEDICAL NETWORK - E

STONIA -

BIOMEDICAL - FYR MAC

EDO

NIA -

BIOMEDICAL NETWORK - I

CELAND -

BIOMEDICAL -BOSNIA HERZ

EGOVNIA-

BIOMEDICAL NE

TW

ORK - CYPRUS-

BIOMEDICAL NETWORK -

BU

LGARIA -

BIOMEDICAL SERBIA & MO

NTENEGRO

BIOMEDICAL NETWORK - L

ITHUANIA - BIOMEDICAL NETWORK

- BEL

GIUM-

BIOMEDICAL NET

WO

RK - PORTUGAL-

48º52.37.38”N 2º19’.27.50”E

Blood Bank Refrigerators

Panasonic MBR-series provide two styles of storage systems, DH-type

(coated steel wire shelf) and GR-type (stainless steel roll-out drawer with card

holder). Designed to conform to AABB criteria, with assured stable and

reliable temperature control utilizing Panasonic original technology: A special

highly efficient compressor designed and developed by Panasonic, to provide

rapid cooling and quiet performance for each model.

79

Refrigerators MBR-305GR / MBR-704GR / MBR-1405GR / MBR-107D(H) / MBR-506D(H)

Stable Temperature Controln Temperature is controlled by two sensors located in the

liquid-loaded monitor bottles, which are in the shape of ablood bag.

n Two thermistor sensors for constantly monitoring thetemperature in both the upper and lower part of thechamber.

n Microprocessor control ensures the most accuratetemperature control available.

n Multi air-flow plenum system ensures excellent temperatureuniformity in larger capacity models. (MBR-704GR, MBR-1405GR).

n Temperature-maintained defrost, designed with thermalsensors and heaters on the evaporator, all under precise

microprocessor control.

Temperature Variations PreventedPanasonic MBR series are designed to minimize cold air losseven with frequent door openings.n Seperated transparant inner doors minimize the chamber

air leakage during door openings.n Foamed-in-place insulation in the walls and

magnetic sealed outer doors with double-pane glasswindow prevent chamber air leakage and promotes completedoor closings.

n Large air circulation fan enables rapid temperaturerecovery after door openings (double fan for MBR-1405GR).

MBR-1405GR1287 LITRES720 Blood bags

450 ml

MBR-704GR617 LITRES360 Blood bags

450 ml

MBR-305GR302 LITRES120 Blood bags

450 ml

Options

Temperature chart recorder is standard built-in on the MBR modelsChart paper RP-G04 (for MBR-305GR, 704GR, 1405GR)Ink pen PG-R (for MBR-305GR, 704GR, 1405GR)Chart paper RP-06 (for MBR- 107D(H), 506D(H))Chart paper RP-G04 (for MBR-305GR, 704GR, 1405GR)

Storage basket MBR-15B (for MBR-107D(H)) 7 bags of 220 ml, max. 8 basketsMBR-16B (for MBR-107D(H)) 4 bags of 450 ml, max. 8 basketsMBR-55B (for MBR-506D(H)) 10 bags of 220 ml, max. 20 basketsMBR-56B (for MBR-506D(H)) 6 bags of 450 ml, max. 20 baskets

Cooling performance:4ºC ±1,5ºC (Ambienttemp. 35ºC)

80

Refrigerators MBR-305GR / MBR-704GR / MBR-1405GR / MBR-107D(H) / MBR-506D(H)

Dimensions

MBR-305GR MBR-704GR MBR-1405GR

User Friendly Designn Selectable storage system (DH-type and GR-type) to suit

user needs.n Fluorescent interior lamp with ON/OFF switch and a large

view window in the outer door provide a clear view ofstored items.

n Digital display is easy to see, and is calibratable throughthe control panel.

Alarm and safety functionsTo ensure the safety of the precious blood supply,Panasonic MBR series provide the following safetyfunctions.n Audible and flashing LED visual alarms with remote alarm

contacts, in the event of power failure, high or low

temperature condition, or due to thermal sensorabnormality.

n Door alarm and key lock are standard features.n Re-activating buzzer, lamp and remote

alarmcontact. (30min. after buzzer stops).n Built-in temperature recorder.

Environment FriendlyPanasonic refrigerators feature commercially available CFC-free, HFC refrigerants and CFC-free insulation.

Temperature Monitoring Featuresn Unified remote monitoring system for Panasonic

Biomedical products (optional).note: descriptions in this catalogue are based on the models MPR-305GR,

704GR, 1405GR

Pull-up characteristicsduring power failure

Pull-up characteristicsduring power failure

Pull-up characteristicsduring power failure

Pull-down characteristicsPull-down characteristicsPull-down characteristics

Pull-up characteristicsduring power failure

Pull-up characteristicsduring power failure

Pull-up characteristicsduring power failure

Pull-down characteristicsPull-down characteristicsPull-down characteristics

Pull-up characteristicsduring power failure

Pull-up characteristicsduring power failure

Pull-up characteristicsduring power failure

Pull-down characteristicsPull-down characteristicsPull-down characteristics

81

Refrigerators MBR-305GR / MBR-704GR / MBR-1405GR / MBR-107D(H) / MBR-506D(H)

* A continuously operating

compressor was used to

obtain data for the three

pull-down graphs.

Performance data MBR-305GR /MBR-704GR / MBR-1405GR

MBR-107D(H) MBR-506D(H)

Unit: mm

MBR-506D(H)425 LITRES120 Blood bags

450 ml

MBR-107D(H)79 LITRES32 Blood bags

450 ml

MBR-305GR

MBR-305GR

MBR-704GR

MBR-704GR

MBR-1405GR

MBR-1405GR

Cooling performance: 4ºC ±1ºC (Ambient temp. 35ºC)

82

CBS Isothermal Freezers feature a patented liquid Nitrogen jacket to

provide uniform storage temperatures in the -190°C range, free from

liquid Nitrogen contact. This innovative design eliminates the risk of

cross-contamination through liquid Nitrogen and the need for additional

packaging to protect valuable cells and tissue.

The world of -190ºC

With a minimal temperature gradient, the full internalvolume of each freezer is available for storing samplesat liquid Nitrogen temperatures making the mostefficient use of available capacity. CBS IsothermalFreezers also provide added user safety by eliminatingcontact or splashing of liquid Nitrogen. All models are

certified to the Medical Device Directive 93/42/EEC:1993 Class IIA and feature the Series 2301 Auto-filland Monitor System providing sample security andease of operation. A wide selection of inventorysystems for vials and bags is offered, and installation,commissioning and calibration service are available.

Name: Lasse Jokinen

Location in our network:

Director of one of the oldest

relations within the European

Network.Oy G.W. Berg & C

o AB, Finland.

Favourite place:

Korvatunturi, Lapland,

This is the village where

Father Christmas lives.

Korvatunturi, Lapland

BIOMEDICAL NETWORK - LISB

ON -

BIOMEDICAL NETWOR

K -

LATVIA - BIOMEDICAL NETW

ORK -

ISRAEL -

BIOMEDICAL N

ETWORK - CROATIA -

BIOMEDICAL NETWORK - EST

ONI

A -

BIOMEDICAL - CZECH REPUB

LIC

-

BIOMEDICAL NETWORK - ICE

LAN

D - BIOMEDICAL -BOSNIA HERZEG

OVNIA-

BIOMEDICAL NETWOR

K -

CYPRUS- BIOMEDICAL NETWORK - BUL

GARIA -

BIOMEDICAL SERBIA & MONTE

NEGRO

BIOMEDICAL NETWORK - GEO

RGI

A -

BIOMEDICAL NETWORK - FINL

AND -

BIOMEDICAL NETWOR

K -

SLOVENIA-

68º03’.00.00”N 29º12.00.00”E

CBS Isothermal -190ºC Dry Storage Freezers

83

The Straw Storage Inventory System is specially designed for the CBS V-1500AB andCBS V-3000AB Isothermal Freezers. This patent-pending Inventory System provides anefficient solution for storing and working with straws, free from liquid Nitrogen contact.Working with a 3-level rotating carousel, the system can hold up to 24.480 straws in 68canisters for the CBS V-1500AB. In combination with the CBS V-3000AB the systemcan hold up to 61.200 straws in 170 canisters .

-195˚C

-190˚C

Rotating carousels provide access tolower storage levels and maximisestorage space.

Use the retrieval tool to place andretrieve canisters quickly and easily.

The upper level provides aconvenientworkspace where canisters can beparked (shown in green) andsamples inspected at -190°C.

Straw StorageInventory System

CBS Isothermal -190ºC Dry Storage Freezers

84

CBS Isothermal -190ºC Dry Storage Freezers

The Isothermal ConceptThe sample storage area is cooled by a liquid Nitrogenjacket surrounding the stainless steel interior, and byNitrogen vapour entering the freezer from the jacket viadirectional vents. This patented technology provides exceptionaltemperature uniformity in the -190°C range, allowing thefull freezer capacity to be used with confidence.The circulation of vapour within the freezer also results inless cold air loss during lid opening and improvedvisibility. This allows full-width lids to be used providingquick, unrestricted access to sample racks.

No Liquid Nitrogen ContactWith no liquid Nitrogen in the storage area, samples can be stored safely in the -190°C range without the risk ofcross-contamination through liquid Nitrogen. TheIsothermal design also provides added user safety withno splashing or contact of liquid Nitrogen when removing racks and samples from the freezer.

Automatic OperationCBS Isothermal Freezers feature the Series 2301 Auto-filland Monitor System, which controls the automatic filling ofthe liquid Nitrogen jacket and provides the user with aneasy to read overview of the freezer temperature andstatus.

Sample SecurityA comprehensive alarm system with remote alarm contactconstantly monitors all aspects of the freezer’s operation.Samples are also protected by lid and control panellocks. The freezer can be monitored by a central BMS ormonitoring system.

Sample StorageA wide selection of inventory systems for vials and bags isavailable to complete the system and optimize samplestorage.

85

CBS Isothermal -190ºC Dry Storage Freezers

VacuumInsulatedJacketing

TemperatureControlledStorage Area

LiquidNitrogenEnvelope

l Outstanding temperature uniformity in the -190°C range.l No loss of storage space.l No cross-contamination through liquid Nitrogen.l User safety with no liquid Nitrogen in the sample storage area.l Automatic operation and filling.l Certified to Medical Device Directive 93/42/EEC:

1993 Class IIA.l Choice of 4 models offering capacities between 9,100 and 45,000 2ml vials.

Key features of the 2301 controllerFeaturesl Compatible with all on site automated LN2 supply

systemsl Availble on all standard and Isothermal LN2 freezersl Programming of LN2 auto-fill levels and cyclesl Sequential filling capabilities, one-fill-all-filll Warm gas by-passl Output data to PC / Printer (USB Port and printer port)l RS-485 communication portl Cryomonitor software for freezer function and alarm

downloadl System validation with print outl Key pad lockl Lid lock��

Front Panel Displayl System status displayl Liquid level inches / centimeters

l Two level temperature display; at lid and inside storagespace

l System status start / stop fill

Alarmsl Visual, audible and remotel High and low LN2 levels in jacketl Temperature deviationl Sensor and valve abnormalityl LN2 source / supplyl Remote alarm contactl Overflow sensor/alarm (optional)

86

CBS Liquid Nitrogen Freezers

Isothermal CarouselThe Isothermal Carousel Liquid Nitrogen Vapor StorageSystem combines the innovative -190°C Isothermal designwith a small opening and an interior rotating carousel. Thesmall opening provides low liquid nitrogen consumption, alightweight, user-friendly lid and a consistently lowtemperature in the freezer. The interior carousel is rotated bya unique ratcheting handle on top of the freezer that willposition samples to the front of the freezer, even with the lidon. Each Isothermal Carousel system includes the advanced2301 auto- fill/monitoring controller to provide security andease of operation.

There are several Isothermal Carousel models available andan extensive selection of inventory racks to store any sizetube, vial, box, microplate, etc. to complete the system.Custom congurations can also be designed to meet anyrequirement.

Controlled Rate Freezer

The 2101 controlled rate freezer meets the highest standards for the programmedfreezing of biological samples. Computer controlled temperatures ensure yoursamples are frozen at precisely the same rate during each run. Freeze protocolsare controlled by either the chamber or the sample temperature. The freezing ratecan be programmed at the optimum rate for each individual sample.

Standard system Includes:l Laptop computer with 2100 softwarel Freezing chamberl Choice of sample rack l 1.2 m LN2 transfer hose

Options:l Choice of sample racks for vials, tubes, straws,

bags & canesl Temperature probes for different sample typesl Roller Cart

l No need to remove one rack to retrieve another rackl No unnecessary exposure to room temperaturesl Carousel is rotated from the outside of the freezer

eliminating the risk of injury or temperature fluctuations.l Exceptional temperature uniformityl Easy access to samples from the front of the freezerl Removable console allows for complete access to the

sample storage space if necessary.l CBS Isothermal Carousel freezers are cooled by a

PATENTED liquid nitrogen jacket, with no liquid in thesample storage space

l The only true DRY STORAGE FREEZER availablel No risk of cross-contamination through liquid nitrogen

contact or the need for special packagingl The isothermal design also provides added user-safety

eliminating contact or splashing of liquid nitrogenl Manufactured to ISO 13485 Standards

87

CBS Liquid Nitrogen Freezers

The 2101 controlled rate freezer comes equipped with a dedicated laptop and 2100programming software as standard to provide the highest levels of flexibility anduser convenience. Benefits include:

l Unlimited programming capabilityl Multi-colour graph for sample, chamber and program temperaturel Sample or chamber temperature set-point controll Continuous control status indicationl Programs and freeze data saved to hard drive or discl Password protected softwarel Selectable password levelsl Searchable database for freeze run historyl Freeze run graphs and data available via any standard computer printerl 30 data field available for each freeze runl Continuous digital and graphical display of time and temperature

during operationl Audible and visual indicators for:

l End of each freeze runl Temperature probesl Freeze run tracking

l On screen help

Five liquid Nitrogen freezers are available ranging in sizesfrom 90 litres to 720 litres, with sample storage capacitiesup to 40,000 2 ml vials or over 3,500 blood bags. Each unitincludes a liquid level auto-fill and alarm system to providesecurity, ease of operation, plus flexibility to operate vaporstorage, immersion storage or a combination of both tostore any type or size of sample. An extensive selection ofstandard inventory racks or canisters and frames areavailable to complete the system. Custom configurationscan also be designed to fit any requirements.

l Standard LN2 Freezers include the 2301 controller

Standard liquid Nitrogen freezers are designed to meet temperature, storage and security

specifications required by laboratories storing frozen samples at cryogenic temperatures.

Standard LN2 Freezers

l ‘XC’, ‘Classic’ and ‘Value Added’ Series fulfil a widerange of storage requirements

l Capacities from 210 to 6,000 2ml vialsl Advanced vacuum and insulation for maximum thermal

performancel Durable, lightweight aluminium construction and roller

bases for easy mobilityl Storage solutions for vials and strawsl Easy access to store and retrieve samplesl Sample security with low-level alarm and lockable lids

(padlock not supplied)

‘XC’ Series – Compact Cryosystems for vial or strawstorage. With roller base and handle mounted low levelalarm.

‘Classic’ Series – Medium capacity storage for vials instandard cryogenic boxes. With roller base and handlemounted low level alarm.

‘Value Added’ Series – Same as ‘Classic’ Series but withthe low level alarm built into a lid console.

Cryosystems

Manual-fill Cryosystems provide versatile, low cost sample storage at cryogenictemperatures with maximum capacity and low liquid Nitrogen consumption.

Fabricated from durable, lightweight aluminum, theshippers contain a hydro-phobic absorbent which holdsthe liquid Nitrogen. The absorbent also repels moistureand humidity, assuring the maximum holding time. Aprotective shipping carton is available for all modelswhich protects the container from being placed on itsside and helps in withstanding the rigors oftransportation. These containers can be used to ship yoursamples with a "non-hazardous" classification throughoutthe world.

The Vapor Shippers are designed for the safe transportation of biologicalsamples at cryogenic temperatures.

Vapor Shippers

88

CBS Liquid Nitrogen Freezers

Lab TanksThe LAB Series dewars use high efficiency super-insulation and aluminum construction to make themlightweight and the most efficient containers available.Their shape and handles make them easy to lift andpour. The LAB Series dewars can also be fitted withpouring spouts, withdrawal devices, or dippers to aidin liquid Nitrogen transfer.

89

CBS Liquid Nitrogen Freezers

The CF-9511 Transport container is also a high-quality unit, primarily for use in moving samples overshorter distances, such as from one lab to another.

90

BioCision - CoolRack®, CoolBox, CoolCell®

CoolProductsThe CoolProducts from BioCision are portable bench-top tools for ensuring

reproducible sample handling and preparation. Its patent-pending products

enable researchers to achieve pre-analytical sample standardization:

experiment to experiment, lab to lab, site to site. The highly thermo-conductive

bench-top tube and plate modules, ice-free cooling containers and alcohol-free

cell freezing containers are used by researchers in the pharmaceutical,

biotechnology, academic and health care industries worldwide.

Problem Solution

91

BioCision - CoolRack®, CoolBox, CoolCell®

CoolRackOrganized and ProtectedCoolRacks rapidly equilibrate to any temperature theycontact. Index, organize and protect samples in ice, dryice, liquid Nitrogen, water baths or any other labtemperature source. Get the benefit of the temperaturewithout the mess!

Cool, (Snap)Freeze or Thaw Insert samples in a CoolRack instead of directly immersinginto ice, dry ice, liquid Nitrogen or water baths.CoolRacks provide temperature consistency and highreproducibility during cooling, (snap)freezing or thawingprocedures, eliminating one often-overlooked variable.

Modular and Versatile CoolRacks accommodate a wide variety of tubes andplates and adapt to any temperature from -200°C through100°C+. Ideal for a wide range of laboratory applicationsfrom collection to processing to transport.

Solution

Name: Kuba Location in our network:Sales representative responsiblefor the south of Poland, SANLAB Spolka CywilnaFavourite place: Mikolajki, This area of Poland isfamous because of many wonderfullakes and its perfect sailing,fishing & water sports possibilities.

Mikolajki, Poland

BIOMEDICAL NETWORK - ALB

ANI

A -

BIOMEDICAL NETWOR

K - POLAND -

BIOMEDICAL NETWOR

K -

FRANCE -

BIOMEDICAL NETWOR

K - FINLAND -

BIOMEDICAL N

ETWORK - CROATIA -

BIOMEDICAL NETWORK - EST

ONIA -

BIOMEDICAL - FYR MACEDON

IA -

BIOMEDICAL NETWORK - ICE

LAN

D - BIOMEDICAL -BOSNIA HERZEG

OVNIA-

BIOMEDICAL NETWOR

K - CYPRUS- BIOMEDICAL NETWORK - B

ULGA

RIA -

BIOMEDICAL SERBIA & MONTE

NEG

RO

BIOMEDICAL NETWORK - LITH

UA

NIA -

BIOMEDICAL NETWORK - BELG

IUM-

BIOMEDICAL NETWOR

K - PORTUGAL-

44º49’.26.98”N 20º27.03.78”E Features CoolRackl Highly reproducible cooling, (snap)freezing and

thawing reduces user errorl Rapid thermo-conductivity through patented

aluminum-alloy constructionl Maintains temperature indefinitely when placed

in direct contact with ice, dry ice, LN2, waterbath, heat block, incubator, oven

l Precision-engineered for superior tube/plate fitand optimal thermal transfer

l -200°C to 100°C+ temperature rangel Type III hard annodized surface to prevent

corrosion and rustl Autoclavable, high-heat sterilizable, or clean

with bleach, RNase Away, common labdetergents and disinfectants

CoolBoxIce-Free Cooling and Freezing Keep tubes and plates cold or frozen on the bench-topin a compact, versatile and portable CoolBox. Insert yourCoolRack or CoolSink module and samples will staycold or frozen for up to ten hours through the use ofinterchangeable, reusable cartridges. All wells stay at aconsistent 0.1˚C temperature uniformity throughout thecooling period eliminating worries of edge-effect.

Snap-Freezing In addition to cooling and freezing with cartridges,CoolBox can be used with dry ice or LN2 to create acompact, portable cryogenic freezing station. Rest aCoolRack module on dry ice or LN2 and get improvedwork flow and high levels of consistency andreproducibility in snap-freezing procedures.

Collect and Process CoolBox instantly organizes, protects and standardizestube and plate sample collection and handling.Compared to directly immersing samples into ice, dry iceor LN2, CoolBox provides a compact and cleanworkstation while delivering highly reproducible coolingand freezing results.

Modular and Versatile CoolBox 30 System accommodates all 30-wellCoolRack tube modules. CoolBox Microplate Systemaccommodates all CoolRack and CoolSink SBS-formatplate and tube modules. Mix and match for use with avariety of tubes and plates at five different temperatures.

92

BioCision - CoolRack®, CoolBox, CoolCell®

Features CoolBoxl Manufactured from highly durable cross-linked

dense polyethylene foaml Use with ice-free cartridges, wet ice, dry ice,

liquid Nitrogen or standard gel packsl +2˚C and -12˚C cartridges are reusable and can

be recharged in a -20˚C freezerl Clean with aqueous detergents, alcohol, bleach

or acid/base viricides. Do not autoclave.l Excellent resistance to fluid absorption,

surface abrasion and rustl For labeling, use lab markers or tape. Repeated

application and removal of tape will not affectsurface

93

BioCision - CoolRack®, CoolBox, CoolCell®

CoolCell-1°C/minute Alcohol-free Cell FreezingAlcohol-free means no fluids, no on-going expense, nomaintenance, no waste and no variability in freeze runs.

Highly ReproducibleWith CoolCell each freeze run profile is exactly the same.The solid core design never varies in cooling rate and,unlike alcohol-filled containers, the insulated designprovides repeatable, constant cooling throughout thefreezing period.

Improved Work Flow CoolCell is ready to use “off the shelf” and is ready againjust minutes after a freeze cycle. Freeze up to 12 screw cap1ml or 2ml cryo vials. The insulated design protects handswhen removing from the -80˚C freezer. No frosty fingers. Nostuck lids.

CoolCell FTS30 is a high capacitycontrolled-rate cell freezing containerfor cryopreservation of 30 cryo vials ina -80°C freezer. The innovative,patent-pending device utilizes a novelalloy and controlled micro-convectiontechnology to evenly draw in coldfreezer air through a bottom intakevalve, uniformly disperse the cold airaround each vial in the central FTSchamber and then release the thermalload from the vials through an exhaust

port on the top of the device. Eachvial achieves a uniform andreproducible -1°C/minute freezingprofile.

The inner removable FTS Vial Moduleholds 30 cryo vials. It can be placedin a biosafety cabinet for efficientloading of the prepared vials and thenplaced into the CoolCell FTS30 forfreezing. Frozen vials can then beremoved in one step on the vial

module and placed into a standard5.5" x 5.5" x 2" cryo storage box.

CoolSystem CRYO provides ice-free coldcryo vial preparation and alcohol-free cellfreezing. CoolBox CFT30 keeps up to 30cryo vials at ice temperature while allowingone-handed opening and closing of seatedvials. Prepared vials are placed in theCoolCell for alcohol-free highlyreproducible freezing in a -80˚C freezer ordry ice locker.

+

94

Vision on Incubation

Panasonic CO2 and Multigas Incubators provide thevery best conditions for cell cultivation, from routinecell culture to the most critical applications. Panasonichas pioneered the development of technologies, whichset new standards for temperature and CO2 control. Inaddition, Panasonic’s contamination controltechnology constantly helps to protect valuablesamples, without downtime or compromise to theincubator’s performance.

World Class DesignPerformance - Panasonic CO2 and Multi-gasIncubators offer outstanding control and rapid recoveryof temperature and CO2/O2 concentration to provideoptimum conditions and reproducible results. Temperature - Direct Heat and Air Jacket technology(DHA) provides precise and uniform temperaturecontrol, with rapid response following door opening.Uniform temperatures (and CO2 levels) are further

enhanced by gentle fan circulation, which unlikeconvection methods of air circulation, is much lessaffected by incubator loading and other factors.

CO2

Panasonic introduced reliable, long-life solid-stateInfrared sensors and PID control of CO2 injection toprovide exceptional CO2 stability and recovery times.Auto-calibration using room air eliminates drift and fancirculation ensures efficient distribution and uniformityof CO2 inside the incubator.

Note: Featured models are the MCO-19AIC/19M. Specifications varybetween models – for details, please refer to the individual modeldescriptions.

Relative HumidityA removable water pan combined with an independentheater at the base of the incubator provides anefficient, cost effective method for maintaining elevatedhumidity levels. The humidifying pan can be easilyremoved and a water level sensor provides an easymaintenance system.

Preventive Contamination Control - Panasonic’sInCu saFe® and SafeCell UV work in combination toprovide the most effective protection againstcontamination during culturing, without downtime oraffecting cultures.

InCu saFe® Copper-Stainless Steel AlloyInCu saFe® copper-stainless steel alloy combines thecorrosion resistance and durability of stainless steel

with the germicidal properties of Copper. The InCusaFe® walls and shelves significantly reduce the risk ofcontamination developing on internal surfaces.

SafeCell UV (U.S. Patent 6255103) Panasonic’s SafeCell UV system with programmable,ozone-free UV lamp sterilises the chamber air, andwater in the humidifying pan.

The UV lamp is completely isolated from the cellcultures and unlike other methods; the SafeCell UVsystem does not trap contaminants inside theincubator or require the temporary removal of criticalcomponents.

Note: Featured models are the MCO-19AIC/19M. Specifications varybetween models – for details, please refer to the individual modeldescriptions.

l CO2 Incubatorsl Multigas Incubatorsl Plant Culture Chambersl Heated Incubatorsl Cooled Incubators

Name: Magda Velichkovska

Location in our network:

Responsible for marketing an

d

PR, she is keeping a good an

d

positive spirit in the

company. Zoral d.o.o.,

FYR Macedonia.

Favourite place:

Kokino in the north

of Macedonia

BIOMEDICAL NETWORK - ALB

ANI

A -

BIOMEDICAL NETWOR

K - POLAND -

BIOMEDICAL NETWOR

K -

FRANCE -

BIOMEDICAL NETWOR

K -

FINLAND -

BIOMEDICAL N

ETWORK - CROATIA -

BIOMEDICAL NETWORK - EST

ONIA -

BIOMEDICAL - FYR MACEDON

IA -

BIOMEDICAL NETWORK - ICE

LAN

D - BIOMEDICAL -BOSNIA HERZEG

OVNIA-

BIOMEDICAL NETWOR

K - CYPRUS- BIOMEDICAL NETWORK - B

ULGA

RIA -

BIOMEDICAL SERBIA & MONTE

NEG

RO

BIOMEDICAL NETWORK - LITH

UA

NIA -

BIOMEDICAL NETWORK - BELG

IUM- BIOMEDICAL NETW

ORK -

PORTUGAL-

95

Vision on Incubation

42º15’.47.03”N 21º57.13.55”E

Kokino, FYR Macedonia

96

Large Scale CO2 Incubator MCO-80IC

The MCO-80IC is ideal for culturing high volumes of patient samples, performing short-term studies, and working with large volume cell culture apparatus. The MCO-80ICincludes Panasonic’s advanced incubator technologies such as InCu saFe® interior, UV decontamination* and solid-state infrared CO2 sensor with P.I.D. control to provideoutstanding performance and anti-contamination control. The incubator also featuresexceptionally low CO2 gas consumption for economic operation.

Large Scale Cell Culture CO2 Incubator

38º38’.59.43”N 34º50’.26.39”E

Name: Ebru & Esra Ildam

Location in our network:

The two leading ladies from

Labor Ildam are practically

raised with selling Panasoni

c

Biomedical equipment

LABOR ILDAM, Turkey.

Favourite place:

Kapadokya, Turkey, because i

t

is one of Turkish most famou

s

and popular tourist destina-

tions, founded 1800 BC.

Kapadokya, Turkey

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

97

Large Scale CO2 Incubator MCO-80IC

* Optional UV sterilisation system for humidity reservoir. See page 157.

MCO-80AIC851 LITRES

Options

Shelf and brackets (InCu saFe®) MCO-80STRoller bottle rack mounting kit MCO-80RBSAutomatic CO2 gas cylinder switchover system MCO-80GCUV system kit MCO-80UVSInner door kit MCO-80IDAutomatic water supply system kit MCO-80ASmA Analogue output for MCO-80IC MCO-420MA

Communications Interface1) MTR-480

1)Can only be fitted with one communications terminal

Superior CO2 and Temperature Controll Horizontal Laminar Airflow SystemThe MCO-80IC features a cross-shelf horizontal air flowsystem, which promotes optimum temperature uniformitythroughout the incubator and contributes to rapidrecovery after door openings. The conditioned air isdirected evenly through the incubator using perforatedside plenums made from Panasonic’s exclusive InCusaFe® copper-enriched stainless steel. The horizontalairflow helps to maintain uniform air circulation and eventemperature distribution when samples are placed in theincubator.

l P.I.D. temperature controlLimits temperature fluctuation to ±0.1˚C.

l Infrared (IR) CO2 sensor with P.I.D. microprocessor control Delivers precise control and fast CO2 recoverycharacteristics.

l Exceptionally low CO2 gas consumption ratesLess than half of a similar competitor unit.

98

Faster CO2 Recovery & Lower CO2 Consumption Panasonic’s large scale cell culture incubator has beendesigned specifically for critical applications in pharmaceutical,biotechnology and clinical investigation.

Large chamber capacity applications require specialconsideration of gas usage and recovery. Panasonic’sproprietary IR sensor with P.I.D. CO2 control algorithm isparamount to the industry’s leading design. An optional innerdoor system (MCO-80ID) is also available to enhance theseresults further.

Large Scale CO2 Incubator MCO-80IC

©2008 SANYO Printed in Japan 2008.3 MA

SHR000

CO2 level recovery characteristics

CO2 Recovery after a 60 second door opening

CO2

leve

l (%

)

6

5

4

3

2

1

0

Door open for 30 sec.Door open for 60 sec.

Temperature level recovery characteristics

(min.)

Tem

pera

ture

(˚C)

38

37

36

35

34

33

320 10 20 30 40

Door open for 30 sec.Door open for 60 sec.

Unit: mm

389.5986

2040

64

806

897

1524

693

Door frame heater

Door glass heater

Frame heater

Temperature level recovery after a 30 seconddoor opening for the SANYO MCO-80IC

(min.)

Tem

pera

ture

(˚C)

37

36

35

34

33

320 10 20 30

(min.)0 10 20 30 40

2CO

leve

l (%

)

5

4

3

2

1

(min.)0 10 20 30

for the competitor model. CO2 Recovery after a 60 second door opening

2CO

leve

l (%

)

5

4

3

2

1

(min.)0 10 20 30

for the SANYO MCO-80IC.

©2008 SANYO Printed in Japan 2008.3 MA

SHR000

CO2 level recovery characteristics

CO2 Recovery after a 60 second door opening

CO2

leve

l (%

)

6

5

4

3

2

1

0

Door open for 30 sec.Door open for 60 sec.

Temperature level recovery characteristics

(min.)

Tem

pera

ture

(˚C)

38

37

36

35

34

33

320 10 20 30 40

Door open for 30 sec.Door open for 60 sec.

Unit: mm

389.5986

2040

64

806

897

1524

693

Door frame heater

Door glass heater

Frame heater

Temperature level recovery after a 30 seconddoor opening for the SANYO MCO-80IC

(min.)

Tem

pera

ture

(˚C)

37

36

35

34

33

320 10 20 30

(min.)0 10 20 30 40

2CO

leve

l (%

)

5

4

3

2

1

(min.)0 10 20 30

for the competitor model. CO2 Recovery after a 60 second door opening

2CO

leve

l (%

)

5

4

3

2

1

(min.)0 10 20 30

for the SANYO MCO-80IC.

Performance data MCO-80IC

©2008 SANYO Printed in Japan 2008.3 MA

SHR000

CO2 level recovery characteristics

CO2 Recovery after a 60 second door opening

CO2

leve

l (%

)

6

5

4

3

2

1

0

Door open for 30 sec.Door open for 60 sec.

Temperature level recovery characteristics

(min.)

Tem

pera

ture

(˚C)

38

37

36

35

34

33

320 10 20 30 40

Door open for 30 sec.Door open for 60 sec.

Unit: mm

389.5986

2040

64

806

897

1524

693

Door frame heater

Door glass heater

Frame heater

Temperature level recovery after a 30 seconddoor opening for the SANYO MCO-80IC

(min.)

Tem

pera

ture

(˚C)

37

36

35

34

33

320 10 20 30

(min.)0 10 20 30 40

2CO

leve

l (%

)

5

4

3

2

1

(min.)0 10 20 30

for the competitor model. CO2 Recovery after a 60 second door opening

2CO

leve

l (%

)

5

4

3

2

1

(min.)0 10 20 30

for the SANYO MCO-80IC.

Control Panel

©2008 SANYO Printed in Japan 2008.3 MA

SHR000

CO2 level recovery characteristics

CO2 Recovery after a 60 second door openingCO

2 le

vel (

%)

6

5

4

3

2

1

0

Door open for 30 sec.Door open for 60 sec.

Temperature level recovery characteristics

(min.)

Tem

pera

ture

(˚C)

38

37

36

35

34

33

320 10 20 30 40

Door open for 30 sec.Door open for 60 sec.

Unit: mm

389.5986

2040

64

806

897

1524

693

Door frame heater

Door glass heater

Frame heater

Temperature level recovery after a 30 seconddoor opening for the SANYO MCO-80IC

(min.)

Tem

pera

ture

(˚C)

37

36

35

34

33

320 10 20 30

(min.)0 10 20 30 40

2CO

leve

l (%

)

5

4

3

2

1

(min.)0 10 20 30

for the competitor model. CO2 Recovery after a 60 second door opening

2CO

leve

l (%

)

5

4

3

2

1

(min.)0 10 20 30

for the SANYO MCO-80IC.

99

Flexibility and Ease of Use l Large capacity, 851 litre CO2 Incubator with adjustableshelving provides flexibility in use.

l Accommodates roller bottle apparatus, 5 bottles wide x 7bottles high (requires optional Mounting Ramp Kit, MCO-80RBS).

l Full view, double paned glass door allows clearobservation of cultured samples.

l Large LED digital display and keypad for greater visibilityand ease of set-up.

Preventative Contamination Controll Incubator interior, plenums and shelving made fromPanasonic’s exclusive InCu saFe® germicidal,

copper-enriched stainless steel.l Heated glass door and door frame heater preventcondensation.

l Optional UV sterilisation system for humidity reservoir.

Humidity SelectionAs standard, the MCO-80IC offers a choice of normal andhigh humidity modes for different application needs. Forreliability and reduced maintenance the humidity reservoirheaters are located on the outside walls of the reservoir andare not susceptible to corrosion or scaling through contactwith water. An optional auto-fill 20 litre secondary water tank(Model MCO-80AS) provides an additional water supply tothe humidity reservoir.

Large Scale CO2 Incubator MCO-80IC

Dimensions

©2008 SANYO Printed in Japan 2008.3 MA

SHR000

CO2 level recovery characteristics

CO2 Recovery after a 60 second door opening

CO2

leve

l (%

)

6

5

4

3

2

1

0

Door open for 30 sec.Door open for 60 sec.

Temperature level recovery characteristics

(min.)

Tem

pera

ture

(˚C)

38

37

36

35

34

33

320 10 20 30 40

Door open for 30 sec.Door open for 60 sec.

Unit: mm

389.5986

2040

64

806

897

1524

693

Door frame heater

Door glass heater

Frame heater

Temperature level recovery after a 30 seconddoor opening for the SANYO MCO-80IC

(min.)

Tem

pera

ture

(˚C)

37

36

35

34

33

320 10 20 30

(min.)0 10 20 30 40

2CO

leve

l (%

)

5

4

3

2

1

(min.)0 10 20 30

for the competitor model. CO2 Recovery after a 60 second door opening

2CO

leve

l (%

)

5

4

3

2

1

(min.)0 10 20 30

for the SANYO MCO-80IC.

Panasonic MCO-80IC Competitor Model

Door Openings 0 2 x 2 x 0 2 x 2 x(Number per day) 30 sec 60 sec 30 sec 60 sec

CO2 Consumption 280 l/day 440 l/day 457 l/day 597 l/day 728 l/day 752 l/day(litres per day)

30kg CO2 Cylinder 60 days 39 days 37 days 28 days 23 days 23 daysRetention Time*

* Test conditions: Set temperature = 37°C, set CO2 = 5%, Ambient temperature = 20°C.* All values are actual test values for reference only, and cannot be guaranteed in operation.

100

CO2 Incubator MCO-20AIC

Background Contamination Control The Panasonic MCO-20AIC is the world’s first cellculture CO2 incubator to employ continuous activebackground ultraviolet light sterilization in combinationwith the passive resistance of a copper-enrichedstainless steel chamber to destroy contaminants in vitrowithout affecting cell cultures and without downtime.

Eliminates HEPA Filter Scrubber andDecontamination Heat CycleThe MCO-20AIC inhibits the growth of mycoplasmas,bacteria, molds, spores, yeasts and fungi without costly

HEPA filter air scrubbers which accumulatecontaminants in the chamber, or disruptive, hightemperature decontamination schemes which canactually encourage growth of heat resistant thermophilicand hyper thermophilic microorganisms in vitro.As a result, the MCO-20AIC offers a sensitive yet robustplatform for short term, high-throughput drug discoveryprojects as well as intermediate and long-term cellculture investigations.

High Performance In Vitro ModelingStable temperature, humidity and CO2 density are

The MCO-20AIC Automatic CO2 Incubator provides a stable cell culture environmentwhere contamination control is a continuous process, not an inconvenience.

Professional Cell Culture CO2 Incubator with UV sterilization

42º38’.30.76”N 18º06’.23.33”E

Name: Goran Koščec (right)

and Darko Grozaj (left)

Location in our network:

Tamiko Instruments d.o.o.,

Zagreb, Croatia, Sales and

Service, working together!

favourite place:

City of Dubrovnik, In a

country rich with history,

Dubrovnik is a real jewel of

the Adriatic.

Dubrovnik, Croatia

BIOMEDICAL NETWORK - LISB

ON -

BIOMEDICAL NETWOR

K -

LATVIA - BIOMEDICAL NETW

ORK -

ISRAEL -

BIOMEDICAL N

ETWORK - CROATIA -

BIOMEDICAL NETWORK - EST

ONI

A -

BIOMEDICAL - CZECH REPUB

LIC

-

BIOMEDICAL NETWORK - ICE

LAN

D - BIOMEDICAL -BOSNIA HERZEG

OVNIA-

BIOMEDICAL NETWOR

K - CYPRUS- BIOMEDICAL NETWORK - B

ULGAR

IA -

BIOMEDICAL SERBIA & MONTE

NEGRO

BIOMEDICAL NETWORK - GEO

RGI

A -

BIOMEDICAL NETWORK - FINL

AND -

BIOMEDICAL NETWOR

K -

SLOVENIA-

101

CO2 Incubator MCO-20AIC

contaminationcontrolled

achieved through a combination of performancesystems supervised by a centralized microprocessorcontroller complete with alarm, programming,calibration and diagnostic protocols exportable toremote databases through optional communicationsports for compliance monitoring.

Direct Heat, Air Jacket (DHA) Heating SystemThe Direct Heat, Air Jacket (DHA) heating systemeliminates the need for a conventional water jacket,while achieving temperature stability, uniformity and fast

recovery following door openings.

Elevated Humidity, Low Water Level WarningTo avoid cell culture desiccation, the MCO-20AICmaintains 95% RH at 37ºC through a combined forcedair and natural evaporation method, which is enhancedby the DHA base heater and protected by an opticalwater level indicator to warn of low water in theremovable humidity pan. A unique optical water levelsensor automatically inserts into the humidity pan whenfilled and replaced.

MCO-20AIC215 LITRES

downtimenone

102

CO2 Incubator MCO-20AIC

Temperature Pull-up Characteristics Temperature Recovery Characteristics Humidity Recovery Characteristics

Time (hr.)0 421 3

40

30

200 54321 403020100 0 40302010

6

5

4

3

2

1

00 40302010

38

37

36

35

34

33

32

100

90

80

70

40

35

30

25

20

MCO-20AIC

Tem

pera

ture

(°C

)

CO

2 le

vel (

%)

Time (min.)

Hum

idity

(%) R

H

Time (min.)

Tem

pera

ture

(°C

)

Time (min.)

Tem

pera

ture

(°C

)

Time (hr.)

Ambient temp. 20°C

Door opening 60 sec.Door opening 30 sec.(same as 60 sec.)

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

CO2 Level Recovery Characterics

Performance data MCO-20AIC

730

770

125

125

620

1515

665

880

80

523

469

34

20

628

Power cord outlet

Front viewSide view

Dimensions

103

CO2 Incubator MCO-20AIC

Time (hr.)0 421 3

40

30

200 54321 403020100 0 40302010

6

5

4

3

2

1

00 40302010

38

37

36

35

34

33

32

100

90

80

70

40

35

30

25

20

MCO-20AIC

Tem

pera

ture

(°C

)

CO

2 le

vel (

%)

Time (min.)

Hum

idity

(%) R

H

Time (min.)

Tem

pera

ture

(°C

)

Time (min.)

Tem

pera

ture

(°C

)

Time (hr.)

Ambient temp. 20°C

Door opening 60 sec.Door opening 30 sec.(same as 60 sec.)

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

CO2 Level Recovery Characterics Temperature decrease characteristics when power failure occurs

Options

Shelf and brackets (InCu saFe®) MCO-58STRoller base MCO-20RBCO2 gas pressure regulator MCO-100LAutomatic CO2 gas cylinder switchover system MCO-21GCExtra inner doors MCO-20IDHalf tray MCO-35ST

Communications Interface1) MTR-480

1)Can only be fitted with one communications terminal

Direct Heat and Air Jacket Heating System

Zone Location Function Energy Microprocessor Controller

Main Side, top Principal heat source Variable Energizes any, all or a (Red) and rear walls combination of heating

elements as required

Base Floor Base heater elevates the humidity reservoir to Variable(Yellow) achieve 95%RH at 37°C

Front Outer door Warms the inner glass in response to ambient conditions; Variable (Green) prevents condensation on glass and around door opening

and promotes temperature uniformity

Air Jacket Side, top Sealed, surrounds interior chamber -- --(White) and rear walls with natural air convection

Insulation Side, top and rear Promotes energy efficiency, -- --(Grey) walls, door reduces effect of ambient temperature

fluctuations on air jacket

104

Cell Culture CO2 Incubator MCO-19AIC

The Panasonic MCO-19AIC CO2 Incubator is designed for demanding and regulatedapplications in the biomedical, pharmaceutical, medical research and clinical laboratory.Representing years of research, development and component testing, the MCO-19AICoffers outstanding performance and advanced, multi-level contamination control toprovide the ideal solution for cell culture protocols.

53º10’.24.96”N 107º39’.45.00”E

Name: Artur Avakov

Location in our network:

Dia-M, Russia,

Business Development Directo

r

favourite place:

Lake Baikal

Lake Baikal, Russia

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K - AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSIA -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

MCO-19AIC170 LITRES

The industry’s most complete cell culture solution for research, clinical and regulated applications.

105

Cell Culture CO2 Incubator MCO-19AIC

DecontaminationThe unique H2O2 decontamination option limitsdowntime to less than three hours when total chamberdecontamination with verification is desired. All interiorcomponents and CO2 sampling loop aredecontaminated in situ. There is no need to remove orreplace critical components.

Active Background Contamination Control fightscontamination while cell culture protocols are inprocess. The patented SafeCell UV treats interior airflowto destroy airborne and humidity pan contaminants.

Exclusive InCu saFe® copper-enriched stainless steelinterior surfaces assure constant germicidal protection.

Control and Monitoringl The MCO-19AIC control and information centre features

a multi-function LCD with intuitive pop-up menu forstraight-forward programming of set-points, alarms andcontroller functions. The LCD displays set-points, actualperformance and incubator status at-a-glance.

l Precise PID control logic provides stable CO2,temperature and humidity conditions.

l Multi-point data logging offers push-button graphical

display. An optional PC interface permits remotetransmission for GMP/GLP protocols as required.

CO2 ControlPanasonic proprietary single-beam, dual detectorinfrared (IR) CO2 sensor delivers precise CO2 controland fast recovery following door openings with nomoving parts.

l Continuous auto-zero calibration is standard.l An optional semi-automatic, one-point span calibration

system is available. (See Options)

Temperature and Humidity Controll The patented Direct Heat and Air Jacket conditioning

system precisely regulates temperature through multipleheating zones under microprocessor control.

l The humidity pan is easy to fill, easy to clean and theautomatic optical sensor advises of low water level.

Cabinet Designl The 170 litre capacity incubator is stackable with field-

reversible doors.l Interior components and adjustable shelves are

configured for easy access.

Options

Model MCO-19AIC(UV) MCO-19AICDecontamination OptionsH2O2 Decontamination Kit MCO-HL MCO-HL1)

H2O2 Vapour Generator (Requires MCO-HL) MCO-HP MCO-HP1)

H2O2 Reagent, pack of 6 bottles, each pre-measured bottle is sufficient for a complete H2O2 decontamination cycle (specially formulated for MCO-19AIC) MCO-H2O2 MCO-H2O21)

SafeCell UV System Kit narrow-bandwidth253.7nm lamp and assembly Built-in MCO-19UVS

Common OptionsSmall inner doors (4)kit MCO-19ID MCO-19IDAutomatic CO2 Cylinder Changeover System MCO-21GC MCO-21GCSemi-automatic one point Gas Calibration Kit MCO-SG MCO-SGRoller Base, for use in single or stacked installations MCO-18RB MCO-18RBInCu saFe® Shelf and Brackets MCO-47ST MCO-47STInCu saFe® Half Tray System MCO-25ST MCO-25ST

Communication interfaces2)

Communication Terminal (RS-232C/RS485) MTR-480 MTR-480Communication Terminal (LAN) MTR-L03 MTR-L03Communication Terminal (Analog 4-20 mA) MCO-420MA MCO-420MA

1) Also Requires SafeCellTM UV kit2) Can only be fitted with one communications terminal

H2O2 Vapour Generator.Shown with connectingcable, standard.

Prep: 15 minutes

Prep: 15 minutes

MCO-19AIC H 0 Decontamination Cycle

(3 Hours)

Conventional High HeatDecontamination

(up to 24 Hours)

Reposition shelves, humidity pan, and plenum within chamber

Finish: 15 minutesReturn shelves, humidity pan, and plenum to normal position

Decontaminate: 7 minutes • H2O2 generator creates vapour; interior fan circulates vapour throughout chamber

Warm up time: 30 minutes • Press H2O2 start button• Chamber warms to 45˚C

Start Cycle: 90 minutesInterior chamber elevates to high heat

UV Resolve: 90 minutes• H O vapour generator automatically shuts off• UV lamp glows for 90 minutes to reduce H O to water vapour

15 min. 30 min. 45 min. 1 h. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 h.

2 2

2 2

2 2

Elapsed time

Decontaminate: 14 hours FinishIncubator must cool from high heat temperatures to near ambient.

Ready

106

Cell Culture CO2 Incubator MCO-19AIC

Hydrogen Peroxide Vapour DecontaminationThe use of low temperature H2O2 sterilisation in biologicalsafety cabinets and barrier isolators is a popular alternativeto ethylene oxide (EtO) as a safer, more efficientdecontamination method. H2O2 has long been widely used inthe pharmaceutical industry and in aerospace research. H2O2

is used to sterilise satellites and interplanetary explorationprobes.

The MCO-19AIC Design Permits Safe, Effective H2O2

DecontaminationUnlike conventional incubators, the unique design features of

the MCO-19AIC permit the safe use of H2O2

decontamination in situ with zero impact on adjacentequipment or the environment, and relative speed to returnthe incubator to service.l The H2O2 decontamination process functions with thepatented Panasonic SafeCell UV system. Following aseven minute H2O2 vaporization, circulation and dwellcycle, the vaporization is stopped and the SafeCell UVlamp turned ON for 90 minutes.

l When exposed to UV light the H2O2 vapour breaks downinto water vapour and oxygen. Throughout the entirecycle the MCO-19AIC airflow system continues to gently

Panasonic H2O2 solution isspecially formulated foroptimal use with the MCO-HP Vapour Generator. Eachpre-measured bottle issufficient for a completeH2O2 sterilization sequence.Unit of issue: six per carton.

Prep: 15 minutes

Prep: 15 minutes

MCO-19AIC H 0 Decontamination Cycle

(3 Hours)

Conventional High HeatDecontamination

(up to 24 Hours)

Reposition shelves, humidity pan, and plenum within chamber

Finish: 15 minutesReturn shelves, humidity pan, and plenum to normal position

Decontaminate: 7 minutes • H2O2 generator creates vapour; interior fan circulates vapour throughout chamber

Warm up time: 30 minutes • Press H2O2 start button• Chamber warms to 45˚C

Start Cycle: 90 minutesInterior chamber elevates to high heat

UV Resolve: 90 minutes• H O vapour generator automatically shuts off• UV lamp glows for 90 minutes to reduce H O to water vapour

15 min. 30 min. 45 min. 1 h. 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 h.

2 2

2 2

2 2

Elapsed time

Decontaminate: 14 hours FinishIncubator must cool from high heat temperatures to near ambient.

Ready

107

Cell Culture CO2 Incubator MCO-19AIC

circulate interior air assuring 100% vapour contact withall interior surfaces and ultimately breaking down theH2O2 vapour as it passes over the UV lamp.

l The location of the interior sample ports of the singlebeam, dual detector IR CO2 sensor creates a slightVenturi flow through the sensor permitting totaldecontamination of the CO2 system at the same time.

l Shape and placement of interior components such asshelves, shelf brackets, plenum covers and the humiditytray permit the components to remain inside the

l MCO-19AIC during the decontamination process,conveniently by passing the need for a separate

autoclave cycle.l Once the cycle is complete, the door locking system isreleased; the door can be opened, interior componentsrepositioned and the incubator is returned to service.

l The H2O2 decontamination cycle is monitored for safetyand cycle status. A physical door interlock and H2O2

neutralization sequence assures total decontaminationand operator safety.

MCO-19AIC configured for decontaminationsequence.

Interior components are reoriented for in situdecontamination. The H2O2 generator is placedon the rear floor. The incubator fan gentlycirculates vapourized H2O2 during thevaporization phase, decontaminating all interiorsurfaces. Following the vaporization cycle theUV lamp reduces H2O2 to tracedecontaminated water.

Incubator configured for decontamination.Generator receptacle is built-in and cappedwhen not in use.

Panasonic MCO-19AIC

14 hours3 hours

BRAND X

H2O2 decontamination vs. high heat sterilization

= Uptime (hours) = Downtime (hours)

108

Cell Culture CO2 Incubator MCO-19AIC

Intelligent Control Interface with Integrated LCD DisplayThe MCO-19AIC Incubator is managed by an integratedmicroprocessor controller with LCD graphical display tosimplify all incubator functions. The PID controllersupervises the incubator’s advanced systems to providestable CO2, temperature and humidity conditions completewith alarm, programming, calibration and diagnosticprotocols.

l A multi-function, high resolution LCD displays set-points,actual performance and incubator status at-a-glance.

l An intuitive Pop-up menu and function keys providestraight-forward programming of set-points, alarms andcontroller functions.

l Standard parameters are factory-set for quick start-up,and all parameters can be changed as required.

l Multi-point data logging offers a graphical display ofselected performance history.

l Logged parameters can be exported to remotedatabases, off-site alarm or data capture systemsthrough optional communication boards for GMP/GLPcompliance monitoring as required. (See Options)

l A remote alarm terminal mounted at the rear of theincubator can be connected to an external alarm system.

l The control panel is centre mounted in the outer door foreasy access and viewing.

Display contrastadjustment

Positive feedbacktactile input buttons

Positive feedback tactileentry and function keys

Visual alarmindicator

Digital alphanumeric LCD displayMessage displayPop-up menu

Menu call button

H2O2 decontamination sequence start key

620 mm

490 mm

580 mm

630 mm

523 mm115 mm

80 mm

469 mm44 mm

665

mm

20

mm

880

mm

125

mm

49 mm34 mm

Dimensions

Performance

Cell Culture CO2 Incubator MCO-19AIC

Menu call button

42º41.45.23”N 23º19’.57.91”E

Name: Teodor Zamfirov

Location in our network:

Director of ELTA’90, Panasonic’s

distributor in Bulgaria.

favourite place:

Alexander Nevski Cathedral, Sofi

a

which is one of the most impress

ive

monuments of Orthodox Christiani

ty

in Bulgaria.

Alexander Nevski Cathedral, Sofia

BIOMEDICAL NETWORK -

LIS

BON -

BIOMEDICAL NET

WORK - LATVIA -

BIOMEDICAL NET

WORK - ISRAEL -

BIOMEDICA

L NETWORK - CROATIA -

BIOMEDICAL NETWORK - E

ST

ONIA -

BIOMEDICAL - CZECH REPU

BLIC -

BIOMEDICAL NETWORK - I

CEL

AND -

BIOMEDICAL -BOSNIA HERZ

EGOVNIA-

BIOMEDICAL NET

WORK - CYPRUS-

BIOMEDICAL NETWORK - B

ULGARIA - BIOMEDICAL SERBIA &

MONT

ENEGRO

BIOMEDICAL NETWORK - G

EORGIA -

BIOMEDICAL NETWORK - F

INL

AND -

BIOMEDICAL NET

WORK - SLOVENIA-

110

CO2 Incubator MCO-18AC

Professional CO2 incubator with preventitive contamination control

l Continuous contamination control with InCu saFe® interior and SafeCell UV (Option)

technologies.

l Direct Heat Air Jacket (DHA) heating system provides accurate temperature control.

l Precise temperature and CO2 control.

l Stackable design for efficient use of available laboratory space.

l Reversible door available for easy installation.

MCO-18AC170 LITRES

111

CO2 Incubator MCO-18AC

Rijswijk, The Netherlands

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

52º01’.55.00”N 4º19’.03.68”E

InCu saFe® Construction for Germicidal ProtectionPanasonic offers exclusive use of InCu saFe® copper-enriched stainless steel alloy interior surfaces within atechnical design created to eliminate contaminationsources and to mitigate the effect of airbornecontaminates introduced through normal use.Chart summarizes test results with four strains ofmycoplasma. Results demonstrate how Panasonic InCusaFe® copper enriched stainless steel alloy offersgermicidal properties of conventional C1100 copper whilemaintaining both corrosion-proof and discoloration-resistant properties of conventional stainless steel 304.

Accurate Temperature and Humidity ControlThe patented Direct Heat and Air Jacket conditioning

system precisely regulates temperature through threeindependent heating zones under microprocessor PIDcontrol. Uniform temperatures are further enhanced bygentle fan circulation. Humidification is achieved byreliable natural evaporation and forced-air circulation andprotected by an automatic optical sensor that advises oflow water level (option).

SafeCell UV Sterilization System (option)The unique air duct system and ultraviolet light sterilizationlamp maintain contamination-free air conditions in thechamber and improve temperature recoverycharacteristics. The circulating chamber air and water inthe humidifying pan are sterilized by ultraviolet light,preventing the spread of bacteria and molds.

Options

Shelf and brackets (InCu saFe®) MCO-47STHalf tray MCO-25ST

Roller base MCO-18RB

CO2 gas pressure regulator MCO-100L

Automatic CO2 gas cylinder

switchover system MCO-21GC

UV system kit MCO-18UVS3

Individual inner doors (4) MCO-19ID

Communications Interfaces1)

Digital (RS232/RS485) MTR-480Analogue MTR-420MAEthernet (LAN) MTR-L031)Can only be fitted with one communications terminal

Name: Harald HilbelinkLocation in our network:General Manager Panasonic Biomedical Sales Europe B.V.’sDutch office.favourite place: Old-Rijswijk my hometown, becauseof its village-like character,cultural and historical importance

112112

CO2 Incubator MCO-18AC

Field-Reversible DoorThe field reversible door can be set up for right-swing orleft-swing door openings, allowing for multipleconfigurations during laboratory installation. A special doorhandle allows for easier door grab and opening in doublestacked configurations.

Automatic CO2 Cylinder Switchover System (option)This system automatically switches from the primary tosecondary gas cylinder when a CO2 gas level drop in the

chamber is detected. The in-use gas cylinder is confirmedon the control panel.

StackabilityTo help ensure effective use of limited space, theseincubators are designed to be stacked in a way that suitsyour work plans. Simply by using the parts provided, youcan create a twin-chamber setup.

580

115

125

490

620

Front viewSide view

80

20 469 44

4934

523

630

665

880

Power cord outlet

Dimensions

Unit: mm Time (hr.)Time (min.) Time (min.) Time (min.)

MCO-18AC

Time (hr.)

Tem

per

atur

e (˚C

)

Tem

per

atur

e (˚C

)

Tem

per

atur

e (˚C

)

Hum

idity

(%) R

H

CO

2 le

vel (

%)

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

Temperature Pull-up Characteristics

Temperature decrease characteristics when power failure occurs

Temperature Recovery Characteristics

Humidity Recovery Characteristics

CO2 Level Recovery Characteristics

113113

CO2 Incubator MCO-18AC

Performance

Time (hr.)Time (min.) Time (min.) Time (min.)

MCO-18AC

Time (hr.)

Tem

per

atur

e (˚C

)

Tem

per

atur

e (˚C

)

Tem

per

atur

e (˚C

)

Hum

idity

(%) R

H

CO

2 le

vel (

%)

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

Temperature Pull-up Characteristics

Temperature decrease characteristics when power failure occurs

Temperature Recovery Characteristics

Humidity Recovery Characteristics

CO2 Level Recovery Characteristics

Time (hr.)Time (min.) Time (min.) Time (min.)

MCO-18AC

Time (hr.)

Tem

per

atur

e (˚C

)

Tem

per

atur

e (˚C

)

Tem

per

atur

e (˚C

)

Hum

idity

(%) R

H

CO

2 le

vel (

%)

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

Temperature Pull-up Characteristics

Temperature decrease characteristics when power failure occurs

Temperature Recovery Characteristics

Humidity Recovery Characteristics

CO2 Level Recovery Characteristics

Time (hr.)Time (min.) Time (min.) Time (min.)

MCO-18AC

Time (hr.)

Tem

per

atur

e (˚C

)

Tem

per

atur

e (˚C

)

Tem

per

atur

e (˚C

)

Hum

idity

(%) R

H

CO

2 le

vel (

%)

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

Temperature Pull-up Characteristics

Temperature decrease characteristics when power failure occurs

Temperature Recovery Characteristics

Humidity Recovery Characteristics

CO2 Level Recovery Characteristics

Time (hr.)Time (min.) Time (min.) Time (min.)

MCO-18AC

Time (hr.)

Tem

per

atur

e (˚C

)

Tem

per

atur

e (˚C

)

Tem

per

atur

e (˚C

)

Hum

idity

(%) R

H

CO

2 le

vel (

%)

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

Temperature Pull-up Characteristics

Temperature decrease characteristics when power failure occurs

Temperature Recovery Characteristics

Humidity Recovery Characteristics

CO2 Level Recovery Characteristics

114

CO2 Incubator MCO-5AC

Preventive Contamination ControlInCu saFe® copper-enriched stainless steel chamber, shelves, and air plenuminhibit surface contamination growth continuously.Airborne and water pan contaminants can also be prevented and continuouslycontrolled by use of a patented SafeCell UV, ultraviolet decontamination method(optional). The ozone-free UV light is shielded from the cell culture area allowing forUV use while cultures remain in the incubation chamber.

Improved Temperature Stability with DHA SystemThree independently controlled heaters plus Panasonic’s exclusive and patentedair jacket construction provide high-precision temperature control, uniformity, andquick recovery after door openings.

Name: July Magadeev

Location in our network:

President Delrus, Russia.

Ekaterinburg and Moscow.

Favourite place:

Kamchatka because of the

wild nature where you can go

camping and fishing.

Kamchatka, Russia

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

54º36’.55.12”N 158º23’.25.04”E

Personal Series Compact CO2 Incubator

Patient Specific, Space Saving, Triple Stackable, Compact Design

CO2 Incubator MCO-5AC

When placed in triple stackableconfigurations (pictured below), this unitmeets GLP (Good Laboratory Practice)requirements by helping to avoid patient-to-patient cross contamination inindividualized patient-specific clinical incubation applications, such as in vitrofertilization and regenerative medicine techniques.

1704 mm

568 mm

Door-mountedcontrol panel

Copper alloystainless steel

Reversible door

Reversible door

115

Ergonomic DesignEven in a triple-stack configuration, the units are space-saving and low-profile, allowing for the most efficient use oflaboratory space and also user-friendly access to the door-mounted control display panel.

Automatic CO2 Cylinder Switchover System (option)This system automatically switches from the primary tosecondary gas cylinder when a CO2 gas level drop in thechamber is detected. The in-use gas cylinder is confirmedon the control panel.

Field-reversible DoorThe field-reversible door can be set up for right-hand orleft-hand door openings, allowing for multipleconfigurations during laboratory installation. A special door handle allows for easier door grab andopening in triple-stacked configurations.

MCO-5AC49 LITRES

115

116

MCO-5ACPerformance data MCO-5AC

Temperature Pull-up Characteristics

Humidity Recovery Characteristics

CO2 Level Recovery Characterics

CO2 Incubator MCO-5AC

Temperature Recovery Characteristics

117

Dimensions MCO-5AC

21

100

350

480

375

568

491.

6

378

548

310

MCO-5AC Dimensions

CO2 Level Recovery Characterics

Temperature decrease characteristics when power failure occurs

Options

Shelf and brackets (InCu saFe®) MCO-30STRoller base MCO-5RBCO2 gas pressure regulator MCO-100LAutomatic CO2 gas cylinder switchover system MCO-5GCUV system kit MCO-19UVSStacking kit MCO-18PS

Communications Interface1) MTR-480

1)Can only be fitted with one communications terminal

CO2 Incubator MCO-5AC

Unit: mm

CO2 gas supply line

indicators (A/B)*

Heater lamp

Digital temperatureindicator

CO2 inject lamp

Digital CO2 densityindicator

UV indicator

Door lamp

Water levelalarm lamp

Upper limitregulator

Over heatlamp

Set key

Calibration key

Alarm buzzer stop key

Gas supply line switching key*

Digit shift key

Numeric shift key

Enter key

* requires optional MCO-5GC

Control Panel

118

CO2 Incubator MCO-175

PID control plus chamber direct sensing systemmaintains a high-precision temperatureenvironment. Through the combination of a PID (Proportional,Integrated and Differential) control system for ultra-precise temperature control and a cabinet-air sensingsystem which accurately monitors inside temperature,this model exhibits exceptional precision within ±0,1degree of the preset temperature. For the temperaturesensor, a durable, ultra-precise PT sensor (Pt 100) isused.

Automatic stop mechanism for Fan Motor and CO2

valve. With this mechanism, the fan motor and CO2

valve are automatically stopped when the door isopened. This minimises air flow from the chamber andreduces air contamination due to the mixing of air.

Automatic control door heaterThe outer door incorporates a door heater that isautomatically controlled. This prevents temperaturedifferences between the chamber and the inner door,thereby preventing condensation on the inner door.

54º38’.19.90”N 24º56’.05.64”E

Name: Valdas Butvilas

Location in our network:

Started his own company,

UAB Elymus, in 1993 to sell

Panasonic biomedical product

s

favourite place:

The Trakai is the most

recognizable place of

Lithuania, just like a nice

post card, and all ancient

history was related to this

castle.

Trakai, Vilnius

BIOMEDICAL NETWORK - ALB

ANI

A -

BIOMEDICAL NETWOR

K - POLAND -

BIOMEDICAL NETWOR

K -

FRANCE -

BIOMEDICAL NETWOR

K -

FINLAND -

BIOMEDICAL N

ETWORK - CROATIA -

BIOMEDICAL NETWORK - EST

ONIA -

BIOMEDICAL - FYR MACEDON

IA -

BIOMEDICAL NETWORK - ICE

LAN

D - BIOMEDICAL -BOSNIA HERZEG

OVNIA-

BIOMEDICAL NETWOR

K - CYPRUS- BIOMEDICAL NETWORK - B

ULGA

RIA -

BIOMEDICAL SERBIA & MONTE

NEG

RO

BIOMEDICAL NETWORK - LITH

UA

NIA -

BIOMEDICAL NETWORK - BELG

IUM-

BIOMEDICAL NETWOR

K - PORTUGAL-

MCO-175170 LITRES

Water Jacketed CO2 Incubator

CO2 Incubator MCO-175

SUS-304 Stainless steel with rounded corner structure Stainless steel featuring superior chemical resistance and a roundedcorner structure are incorporated within the cabinet interior. Theshelves, shelf supports and shelf support tabs are easily removableto allow thorough cleaning and sterilization.

Specific Tube for CO2 Gas A specific tube is used for supply and sampling of the CO2. Featuringsuperior mold resistance and enabling autoclave sterilization, thetube conforms to the Japanese regulations for Medical and Healthand Food Hygiene, eliminating causes of contamination.

119

Dimensions

620 605

490 505

880

665

15

15115

110

30

35

620

490

15

15

605

505

88066

5

20

80

35

115

110

20

20 40

710

100

480

20

770

130615

490

900

880

620

505

690

40

Power cord outlet

15 15

MCO-17AC

MCO-15AC

MCO-175

620 605

490 505

880

665

15

15115

110

30

35

620

490

15

15

605

505

88066

5

20

80

35

115

110

20

20 40

710

100

480

20

770

130615

490

900

880

620

505

690

40

Power cord outlet

15 15

MCO-17AC

MCO-15AC

MCO-175

5

4

3

2

1

9895

90

80

700 5 10 15 20 25 30

CO2level(V/V%)

CO2 level recovery characteristicswhen dehumidifier is incorporated.

CO2 level recoverycharacteristicswithout dehumidifier

shows CO2 level in chamber

Humidity(RH%)

A compact electronic dehumidifier plus a thermal conductivity CO2 sensor produces a high-precision CO2 environment

Options

Stacking kit MCO-175SBCO2 pressure regulator MCO-100LWater preservative agent MCO-100C (cleaner #1000)Extra shelf MCO-47STHalf tray MCO-25ST

Water Jacketed MCO-175 System The large size MCO-175 model incorporates awater jacketed system which takes advantage ofthe heat retention characteristics of water.Because there is no sudden temperature changeor loss of temperature during power failure, astable temperature environment is ensured.

Unit: mm

120

Multi-gas Incubator MCO-19M

InCu saFe® Construction for GermicidalProtectionPanasonic’s exclusive InCu saFe® copper-enrichedstainless steel alloy interior surfaces, plenum andshelving eliminate contamination sources andmitigate the effect of airborne contaminatesintroduced through normal use.

SafeCell UVAirborne and water contaminants in the waterpan can also be eliminated by patented SafeCellUV, an automatic ozone-free ultraviolet lamp,without affecting cell cultures (option).

Industry-first H2O2 decontamination systemPanasonic unique high-speed decontaminationsystem utilizing vaporized H2O2 offers time-saving and documented chamberdecontamination with complete safety. Wholedecontamination process takes less than threehours, saving valuable time. for more detailed information see page 106

Accurate Temperature and Humidity ControlThe patented Direct Heat and Air Jacketconditioning system precisely regulatestemperature through three independent heating

State-of-the-art Professional Cell Culture Multi-gas incubator

The MCO-19M automatic air jacket multi-gas incubator provides precise CO2 and O2

level controls to realise a stable cell culture environment. It features multiple-patentedtechnologies to safely achieve in-vitro performance.

Name: Igor Kashintsev

Location in our network:

Commercial director of

Lab Biomed, Russia

favourite place:

Sakhalin isle, Russia

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

Intelligent Control Interface with Integrated LCD DisplayThe MCO-19M Incubator is managed by an integrated microprocessor controller withLCD graphical display to simplify all incubator functions. The PID controller supervisesthe incubator’s advanced systems to provide stable CO2, O2, temperature and humidityconditions complete with alarm, programming, calibration and diagnostic protocols.

121

Multi-gas Incubator MCO-19M

zones under microprocessor PID control. Uniformtemperatures are further enhanced by gentle fan circulation.Humidification is achieved by reliable natural evaporation andforced-air circulation and protected by an automatic opticalsensor that advises of low water level.

Immediate RecoveriesPanasonic proprietary singlebeam, dual detector infrared CO2

sensor delivers precise CO2 control quick recovery followingdoor openings, and auto sampling with no moving parts.Along with a zirconia O2 sensor, a PID control is used for fastO2 level control.

Sakhalin, Russia

50º13’.28.84”N 143º00.10.38”E

MCO-19M170 LITRES

122

Multi-gas Incubator MCO-19M

Newly-designed Middle Door with Small Doors(standard equipment)Utilizing “Middle Door” with 4 small doors attached, anda full door opening is not needed for removing cellcultures.l “Middle Door” can open/close by itself.l “Middle Door” is reversible like the outer door.

Graphical Control PanelThe MCO-19M control and information center includes

an intuitive pop-up menu, graphic LCD for inputs,outputs and performance at-a-glance.

Ergonomic Cabinet DesignThe 170 liter-capacity, low profile cabinet is stackablewith the field-reversible doors.Convenient, space efficient inventory management issimplified through a system of adjustable, extendable,perforated shelves. To permit vertical airflow. All shelvesare made from InCu saFe®

CO2 Level Recovery Characteristics

Temperature Pull-up Characteristics

Temperature decrease characteristics when power failure occurs

Temperature Recovery Characteristics

Humidity Recovery Characteristics

Time (min.)

Tem

pera

ture

(˚C

)

Time (hr.)

CO

2 le

vel (

%)

O2

leve

l (%

)

Time (min.)

Hum

idity

(%) R

H

Time (min.)Time (min.)

Tem

pera

ture

(˚C

)

Time (hr.)

Tem

pera

ture

(˚C

)

O2 Level Recovery Characteristics

One small inner door opening 30 sec. (without N2 bubbling)One small inner door opening 60 sec. (without N2 bubbling)One small inner door opening 30 sec. (with N2 bubbling)One small inner door opening 60 sec. (with N2 bubbling)

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

620 630

490 523

880

665

580 469 20

44

80

34 49

115

125

123

Multi-gas Incubator MCO-19M

DimensionsCO2 Level Recovery Characteristics

Temperature Pull-up Characteristics

Temperature decrease characteristics when power failure occurs

Temperature Recovery Characteristics

Humidity Recovery Characteristics

Time (min.)

Tem

pera

ture

(˚C

)

Time (hr.)

CO

2 le

vel (

%)

O2

leve

l (%

)

Time (min.)

Hum

idity

(%) R

H

Time (min.)Time (min.)

Tem

pera

ture

(˚C

)

Time (hr.)

Tem

pera

ture

(˚C

)

O2 Level Recovery Characteristics

One small inner door opening 30 sec. (without N2 bubbling)One small inner door opening 60 sec. (without N2 bubbling)One small inner door opening 30 sec. (with N2 bubbling)One small inner door opening 60 sec. (with N2 bubbling)

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

Door opening 30 sec.Door opening 60 sec.

Options

Shelf and brackets (InCu saFe®) MCO-47STHalf tray MCO-25STRoller base MCO-18RBCO2 gas pressure regulator MCO-100LAutomatic CO2 gas cylinder switchover system MCO-21GCUV system kit MCO-18UVS2

Communications Interface1) MTR-480

1)Can only be fitted with one communications terminal

124

Multi-gas Incubator MCO-5M

The MCO-5M automatic air jacket multi-gas incubator provides precise CO2 and O2

level controls to realise a stable cell culture environment. It features multiple-patentedtechnologies to safely achieve in-vitro performance. Also, the MCO-5M has beencleared by the US FDA for In-Vitro Fertilization (IVF) use.

Name: Petr Ulman

Location in our network:

Selling Panasonic Biomedical

equipment to the „industrial

market like pharmaceutical c

om-

panies. Schoeller Instrument

s

s.r.o., Czech Republic.

Favourite place:

Minibrewery and pub „U Fleku

“,

Famous for it's Pilz, this i

s

an old brewery

established in 1499.

Minibrewery and pub „U Fleku“, Prague, Czech Republic

BIOMEDICAL NETWORK - LISB

ON -

BIOMEDICAL NETWOR

K -

LATVIA - BIOMEDICAL NETW

ORK -

ISRAEL -

BIOMEDICAL N

ETWORK - CROATIA -

BIOMEDICAL NETWORK - EST

ONI

A -

BIOMEDICAL - CZECH REPUB

LIC

-

BIOMEDICAL NETWORK - ICE

LAN

D - BIOMEDICAL -BOSNIA HERZEG

OVNIA-

BIOMEDICAL NETWOR

K -

CYPRUS- BIOMEDICAL NETWORK - BUL

GARIA -

BIOMEDICAL SERBIA & MONTE

NEGRO

BIOMEDICAL NETWORK - GEO

RGI

A -

BIOMEDICAL NETWORK - FINL

AND -

BIOMEDICAL NETWOR

K -

SLOVENIA-

50º04’.42.65”N 14º25’.01.15”E

Professional Cell Culture Compact Multi-gas Incubator

Rapid RecoveryExceptional CO2 recovery is obtained by thecombination of a unique P.I.D. TC sensor with longlifespan. Additionally, along with a zirconia O2 sensor,P.I.D. control is used for fast O2 level control. The N2

gas bubbler in the water pan helps recover humiditylevel quickly after door openings.

Water Level SensorThe humidity pan has an optical water level sensor towarn of low water level.

Automatic Gas Cylinder Switchover SystemThis system automatically switches from the primary tosecondary gas cylinder when the O2 gas level does notchange while an injection valve is open. OptionalSwitchover for CO2 gas is available.

Preventive Contamination ControlInCu saFe® copper enriched stainless steel chamberwith coved corners inhibits bacteria growth on itssurface continuously. Airborne and water contaminantsin the water pan can also be eliminated by patented

125

Multi-gas Incubator MCO-5M

SafeCell UV, an automatic ozone-free ultraviolet lamp(option), without affecting cell cultures.

Improved Temperature Stability with D.H.A. SystemP.I.D. controlled 3-way heaters plus Panasonic’s proprietaryD.H.A. (Direct Heat and Air jacket) provides a high-precision temperature environment, and minimizes the riskof condensation and subsequent contamination.

Dimensions MCO-5M

480

350

Access port

375

575

21

100

37

548

310

Dimensions 18M

Power cord outlet

Front view Side view

Front view Side view

125

115

580

490

620

3449

4446920

880

665

80

523

630

Dimensions

Unit: mm

MCO-5M49 LITRES

Options

Shelf and brackets (InCu saFe®) MCO-30STRoller base MCO-5RBCO2 gas pressure regulator MCO-100LAutomatic CO2 gas cylinder switchover system MCO-5GCUV system kit MCO-19UVS

Communications Interface1) MTR-480

1)Can only be fitted with one communications terminal

126

Plant Growth Chamber MLR-352 / MLR-352H

l Graphic LCD provides easier operation

l Programmable temperature, lighting and humidity function (MLR-352H)

l Microprocessor PID control and Refrigeration Capacity Control

l Data logging function

The wide variety of temperatures and lighting patterns thatare essential in various research and testing can now beaccurately reproduced and controlled. And humiditycontrol too! Microprocessor PID control of temperatureand humidity (0˚C to +50°C, 0 to 20,000lux and 55 to90%RH resp.) create the optimum environments forvarious applications.

l Microprocessor PID and Refrigeration Capacity controlminimise temperature fluctuations and thereby improvetemperature control. This allows superior precisionexperiments plus energy and electricity savings.

l Programmable temperature function is perfect fortemperature cycle and vernalization treatmentresearch.

– 12-step programmes x 10 patterns can be stored.– Selectable clock mode or timer mode.– Multiple programmes can be

“connected” (Join mode).– Starting day and time of operation can be

programmed.

Versatile Plant Growth Chamber

Name: Hugo Pettai

Location in our network:

Sales representative of

Panasonic biomedical product

s

at G.W. Berg OU, Estonia

Favourite place:

The old city of Tartu,

Center of culture and

history in Estonia.

BIOMEDICAL NETWORK -

ALBANIA -

BIOMEDICAL NE

TW

ORK - POLAND -

BIOMEDICAL NE

TW

ORK - FRANCE -

BIOMEDICAL NE

TW

ORK - FINLAND -

BIOMEDIC

AL N ETWORK - CROATIA -

BIOMEDICAL NETWORK - E

STONIA -

BIOMEDICAL - FYR MAC

EDO

NIA -

BIOMEDICAL NETWORK - I

CELAND -

BIOMEDICAL -BOSNIA HERZ

EGOVNIA-

BIOMEDICAL NE

TW

ORK - CYPRUS-

BIOMEDICAL NETWORK -

BU

LGARIA -

BIOMEDICAL SERBIA & MO

NTENEGRO

BIOMEDICAL NETWORK - L

ITHUANIA - BIOMEDICAL NETWORK

- BEL

GIUM-

BIOMEDICAL NET

WO

RK - PORTUGAL-

127

Plant Growth Chamber MLR-352 / MLR-352H

l Operation data of approximately last 2 weeks (6-minute intervals) is automatically recorded.– The data can be viewed on the control panel.– The data can be transmitted to a PC (CSV data via

RS-232C, interface board MTR-480 required).

l Easy calibration: temperature and humidity can be calibrated easily through the control panel.

l Small and lightweight, high-molecular membrane-typehumidity sensor also boasts a high degree of accuracy

and reproducibility. Of the newest high-molecularmembrane type, the humidity sensor accurately measureschamber humidity (MLR-352H only).

Control PanelGraphic LCD display with pop-up menu function on controlpanel provides more visual display and allows intuitiveoperation.

MLR-352H294 LITRES

Applications: l Plant growth l Culture of plant cells, tissue and organs l Acclimatization and rearing of plants l Incubation and rearing of insects l Electronic testing l Food testing

58º22’.15.18”N 58º22’.15.18”E

Tartu, Estonia

128

Plant Growth Chamber MLR-352 / MLR-352H

Switch box

LCD Control panel

Door switch

Air intake

Side doors fluorescent lamps

Adjustablesshelves

Inner door

Main door

Air outlet

Power switch

Casters and adjustable legs

Evaporation tray

60

50

40

30

20

10

0

-10

All fluorescent lamps off (LS 0) All fluorescent lamps on (LS 5)

0.5 1 1.5 2 2.5 3 3.5 40

20000

15000

10000

5000

0

50

200

150

0

LS0 LS2

LS1 LS3

1 2 3 9 15 (ST)

LS4 LS5

100

90

80

70

60

50

40

30

20

10

010 20 30 40 50

Set temperature (˚C)

Hum

idity

(%R

H) Controllable range

100

90

80

70

60

50

40

30

20

10

010 20 30 40 50

Set temperature (˚C)

Controllable range

Pull down, Pull up performance (The chamber temperature of center)

Performance data MLR-352 / MLR-352H

129

Plant Growth Chamber MLR-352 / MLR-352H

Humidity Control Range (MLR-352H only) Dimensions

60

50

40

30

20

10

0

All fluorescent lamps off (LS 0) All fluorescent lamps on (LS 5)

10 2 3 4

20000

15000

10000

5000

0

50

200

150

0

LS0 LS2

LS1 LS3

1 2 3 9 15 (ST)

LS4 LS5

100

90

80

70

60

50

40

30

20

10

010 20 30 40 50

Set temperature (˚C)

Hum

idity

(%R

H) Controllable range

100

90

80

70

60

50

40

30

20

10

010 20 30 40 50

Set temperature (˚C)

Controllable range

Unit: mm

Options

Communications Interface MTR-480

Graphic LCD Control forLCD contrast

Characterinput keys

Selection &Enter keys

Menubutton

Controls for High &Low temp. alarm

Pop-up menu

130

Cooled and Heated Incubators MIR-154 / MIR-254 / MIR-554 / MIR-162 / MIR-262

Panasonic's MIR series incubators have been recognised as exceptional units suitable fora wide range of applications. The wide variety of temperatures and lighting patterns thatare essential in biological research and environmental studies can now be accuratelyreproduced and controlled.

Programmable Operation Function withMicroprocessor ControlCombining flexible Temperature (H), Light ON/OFF (L)and Time control (T), a maximum 12-step plus constantoperation or max. 12-step repeating operation can beprogrammed according to the experimentationrequirements. A program can be set to repeat for aminimum of one time to a maximum of 98 times orcontinuous repeat.

Program input is simple and the incubatoraccommodates a range of diversified experimentation

requirements, and is ideal for experimentation duringnight time and holidays, experimentation that requiressettings to be changed and microorganism culture andpreservation.

Also new MIRs offer the choice of timer mode, 24-hoursclock mode and Timer mode to suit the user'sexperiment. Up to 10 programs can be stored forconvenient retrieval and set-up of frequently runexperiments. Individual programs can be combined usingthe Join function. Constant operation mode without stepoperation is also available.

53º13’.16.10”N 1º52.07.10”E

Name: Paul Freeland

Location in our network:

Senior Product Manager,

responsible for the introduc

tion

and support of Panasonic

biomedical products in Europ

e.

Favourite place:

Peak District National Park,

outstanding countryside and

just

over 1 hour drive away.

Peak district, United Kingdom

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY- Versatile cooled incubators for a wide range of experimentalneeds

Improved Experimentation of Repetitive Operation and Operability

131

Cooled and Heated Incubators MIR-154 / MIR-254 / MIR-554 / MIR-162 / MIR-262

Wide Temperature Control Rangefrom -10°C to +60°C With a wide temperature range from -10°C to +60°C, Panasonic CooledIncubators allow a full range of preciseexperiments including environmentaltests to microorganism cultures andplant germination tests.

Precise Microprocessor TemperatureControl Panasonic Cooled Incubatorsincorporate a high precisionmicroprocessor temperature controlcombined with a heater PID andcompressor ON-OFF system.

Intuitive Operation with LCD Display l Easy operability by LCD display and

pop up menul 24-hour mode and timer mode areselectable.

l Combination of multiple programs inJoin function

l Booking of operation start date andhour

l Operation data can be auto-recordedand graphical displayed.

l Data can be sent to PC using optionalcommunication interface (MTR-480)

l Chamber Light ON-OFF control

Condensation Prevention (MIR-554 only) A humidity reduction mode helpsreduce inner chamber condensation thatmay occur during high temperatureoperation

Prevents Medium from Drying Out(MIR-154, 254 only) A DC fan isdesigned to be aimed obliquely upwardto prevent direct wind against samples.This reduces medium drying by approx50% in MIR-154, and by approx 15% inMIR-254.

Meticulous Design for ComfortableOperation New MIRs are crafted with acomfortable rounded corner design andoffer a reversible door for a choice ofleft or right-hand door opening. Lowvibration setting is also availabledepending on the sample to becultured. (Reversible door is unavailablefor MIR-554.)

Options

Stacking kit MIR-S154SB (MIR-154 only) Door Padlock Bracket MIR-LP (MIR-154, 254 only) (Padlock not supplied)Additional Illumination kit MIR-L15Inner doors MIR55ID (MIR-554 only) Door Window Blanking Platefor MIR-154 MIR-154BP for MIR-254 MIR-254BPCommunications Interface MTR-480

High-precision Temperature Environment

MIR-154

Chamber pull-down/pull-up characteristics(Ambient temperature 20˚C Power source: AC100V/50Hz)

Temperature pull-down characteristics for thermal load in chamber (Ambient temperature 35˚C Power source: AC100V/50Hz)

Time (Hr)

50

40

30

20

10

0

–10

50

40

30

20

10

0

–10

0 1 2 0 1 2 3

Time (Hr)

*The data shown above are taken with the fluorescent lamp turned off.*Characteristics may vary depending on the product or operating conditions.

*The data shown above are taken with the fluorescent lamp turned off.*Characteristics may vary depending on the product or operating conditions.

*The data shown above are taken with the fluorescent lamp turned off.*Characteristics may vary depending on the product or operating conditions.

Ambienttemperature 20˚C

Ambient temperature 35˚C

Chamber thermal load 300W

Chamber thermal load 200W

Chamber thermal load 100W

Chamber pull-down/pull-up characteristics(Outside air temperature 20˚C Power source: AC 100V/50Hz)

Pull-down characteristics for thermal load in chamber(Outside air temperature 35˚C Power source: AC 100V/50Hz)

Time (Hr)

-40

60504030

70

20100

-10-20-30

631- 21 540

Cha

mb

erte

mp

erat

ure

(˚C)

Cha

mb

erte

mp

erat

ure

(˚C)

Time (Hr)

50

40

30

20

10

0

–10

–20

–301 2 3 4 5 6 7

Chamber pull-down/pull-up characteristics(Outside air temperature 20˚C Power source: AC 100V/50Hz)

Temperature pull-down characteristics for thermal load in chamber (Ambient temperature 35˚C Power source: AC100V/50Hz)

1 2 3 4 5 6 7

1 2 3 4 5 6 7

Ambient temperature 35˚C

Chamber thermal load 120W

Chamber thermal load 75W

Chamber thermal load 0W

Ambienttemperature 20 °C

50

40

30

20

10

0

–10

–20

–30

Ambient temperature 35˚C

Chamber thermal load 225W

Chamber thermal load 75W

Chamber thermal load 0W

Time (Hr) Time (Hr)

-40

60504030

70

20100

-10-20-30

631- 21 540

Ambienttemperature 20˚C

MIR-254

MIR-553

Cha

mb

erte

mp

erat

ure

(˚C)

Cha

mb

erte

mp

erat

ure

(˚C)

Cha

mb

erte

mp

erat

ure

(˚C)

Cha

mb

erte

mp

erat

ure

(˚C)

132

Cooled and Heated Incubators MIR-154 / MIR-254 / MIR-554 / MIR-162 / MIR-262

Performance data

Energy Savings In addition to a microprocessor-controlled high efficientheater output and compressor ON/OFF, a renewal controlprogram and low heat-emission inner chamber fan are newlyadopted that allow high-energy saving operation over awider range of ambient environments.

Automatic Defrosting To combat annoying frost during low temperature operation,new MIRs provide an automatic defrost function thatoperates automatically at a specified time every day. Manualdefrosting is also selectable.

Light Timer Control On-Off programmed timer control for initially equippedfluorescent light (15W x 1pc) is available. Optional lightaddition kit (MIR-L15) can add three more fluorescent lightsinto the chamber ceiling, giving approx. 3000lx in 30 cmbelow from the light sources.

Environmentally Conscious Microprocessor controlled optimum control results in highenergy savings and a HCFC free foamed-in-place rigidpolyurethane insulator also helps save energy.

MIR-154

Chamber pull-down/pull-up characteristics(Ambient temperature 20˚C Power source: AC100V/50Hz)

Temperature pull-down characteristics for thermal load in chamber (Ambient temperature 35˚C Power source: AC100V/50Hz)

Time (Hr)

50

40

30

20

10

0

–10

50

40

30

20

10

0

–10

0 1 2 0 1 2 3

Time (Hr)

*The data shown above are taken with the fluorescent lamp turned off.*Characteristics may vary depending on the product or operating conditions.

*The data shown above are taken with the fluorescent lamp turned off.*Characteristics may vary depending on the product or operating conditions.

*The data shown above are taken with the fluorescent lamp turned off.*Characteristics may vary depending on the product or operating conditions.

Ambienttemperature 20˚C

Ambient temperature 35˚C

Chamber thermal load 300W

Chamber thermal load 200W

Chamber thermal load 100W

Chamber pull-down/pull-up characteristics(Outside air temperature 20˚C Power source: AC 100V/50Hz)

Pull-down characteristics for thermal load in chamber(Outside air temperature 35˚C Power source: AC 100V/50Hz)

Time (Hr)

-40

60504030

70

20100

-10-20-30

631- 21 540

Cha

mb

erte

mp

erat

ure

(˚C)

Cha

mb

erte

mp

erat

ure

(˚C)

Time (Hr)

50

40

30

20

10

0

–10

–20

–301 2 3 4 5 6 7

Chamber pull-down/pull-up characteristics(Outside air temperature 20˚C Power source: AC 100V/50Hz)

Temperature pull-down characteristics for thermal load in chamber (Ambient temperature 35˚C Power source: AC100V/50Hz)

1 2 3 4 5 6 7

1 2 3 4 5 6 7

Ambient temperature 35˚C

Chamber thermal load 120W

Chamber thermal load 75W

Chamber thermal load 0W

Ambienttemperature 20 °C

50

40

30

20

10

0

–10

–20

–30

Ambient temperature 35˚C

Chamber thermal load 225W

Chamber thermal load 75W

Chamber thermal load 0W

Time (Hr) Time (Hr)

-40

60504030

70

20100

-10-20-30

631- 21 540

Ambienttemperature 20˚C

MIR-254

MIR-553

Cha

mb

erte

mp

erat

ure

(˚C)

Cha

mb

erte

mp

erat

ure

(˚C)

Cha

mb

erte

mp

erat

ure

(˚C)

Cha

mb

erte

mp

erat

ure

(˚C)

MIR-154 MIR-254

MIR-154123 LITRES

MIR-254238 LITRES

Cooled and Heated Incubators MIR-154 / MIR-254 / MIR-554 / MIR-162 / MIR-262

MIR-154

Chamber pull-down/pull-up characteristics(Ambient temperature 20˚C Power source: AC100V/50Hz)

Temperature pull-down characteristics for thermal load in chamber (Ambient temperature 35˚C Power source: AC100V/50Hz)

Time (Hr)

50

40

30

20

10

0

–10

50

40

30

20

10

0

–10

0 1 2 0 1 2 3

Time (Hr)

*The data shown above are taken with the fluorescent lamp turned off.*Characteristics may vary depending on the product or operating conditions.

*The data shown above are taken with the fluorescent lamp turned off.*Characteristics may vary depending on the product or operating conditions.

*The data shown above are taken with the fluorescent lamp turned off.*Characteristics may vary depending on the product or operating conditions.

Ambienttemperature 20˚C

Ambient temperature 35˚C

Chamber thermal load 300W

Chamber thermal load 200W

Chamber thermal load 100W

Chamber pull-down/pull-up characteristics(Outside air temperature 20˚C Power source: AC 100V/50Hz)

Pull-down characteristics for thermal load in chamber(Outside air temperature 35˚C Power source: AC 100V/50Hz)

Time (Hr)

-40

60504030

70

20100

-10-20-30

631- 21 540

Cha

mb

erte

mp

erat

ure

(˚C)

Cha

mb

erte

mp

erat

ure

(˚C)

Time (Hr)

50

40

30

20

10

0

–10

–20

–301 2 3 4 5 6 7

Chamber pull-down/pull-up characteristics(Outside air temperature 20˚C Power source: AC 100V/50Hz)

Temperature pull-down characteristics for thermal load in chamber (Ambient temperature 35˚C Power source: AC100V/50Hz)

1 2 3 4 5 6 7

1 2 3 4 5 6 7

Ambient temperature 35˚C

Chamber thermal load 120W

Chamber thermal load 75W

Chamber thermal load 0W

Ambienttemperature 20 °C

50

40

30

20

10

0

–10

–20

–30

Ambient temperature 35˚C

Chamber thermal load 225W

Chamber thermal load 75W

Chamber thermal load 0W

Time (Hr) Time (Hr)

-40

60504030

70

20100

-10-20-30

631- 21 540

Ambienttemperature 20˚C

MIR-254

MIR-553

Cha

mb

erte

mp

erat

ure

(˚C)

Cha

mb

erte

mp

erat

ure

(˚C)

Cha

mb

erte

mp

erat

ure

(˚C)

Cha

mb

erte

mp

erat

ure

(˚C)

Automatic Setting Temperature Alarm When the chamber temperature deviates more than ±1 to ±5°C, alldigits of the digital indicator flash. Fifteen minutes (default) later abuzzer will sound. This system also automatically allowsprogrammed operation or setting value changes.

Independent Over-temperature Protection Device This incubator incorporates an excessive temperature preventioncircuit that protects experimentation materials in the rare event thata temperature abnormality does occur. This system turns off theheater and chamber fan motor when too high a temperature isdetected, and turns off the compressor when too low atemperature is detected.

MIR-554

MIR-554406 LITRES

Sample program 1:24-hour clock mode10 Steps, Cycle: 31 timesThis is one Cycle consisting of 10 Steps,

which is repeated 31 times in this Program.

(Max. is 98 cycles or continuous repeat) At

the starting of the program, select “Clock

mode” on the running mode screen.

Sample program 2:Timer Mode2 Steps, Cycle: Continuous repeatThis is one Cycle consisting of 2 Steps,

which is repeated continuously in this

Program. (Max. is 98 cycles or continuous)

At the starting of the program, select

“Timer mode” on the running mode screen.

Programmable operation with microcomputer control

Programmed Memory Backup MechanismShould the power source be interrupted due to powerfailure or other event, programmed data remainsstored in memory. When the power source isrestored, operation can be continued according to thepredetermined program.

Automatic Return Buzzer Switch After an abnormality occurs, the alarm automaticallyswitches to the ON mode, even if the operator forgetsto return the alarm buzzer to the ON mode, thusensuring safe and secure operation.

Tamper Proof A key lock function is provided so that settings maynot be changed unintentionally.

Self Diagnostic Function Should a malfunction occur, the location of themalfunction can be digitally indicated, allowing quickoperator response.

Panasonic DAQ System Panasonic original DAQ (data acquisition) softwareenables remote monitoring of cooled incubators.

133

Alarm and Security System to Protect Sample Safety

134

Cooled and Heated Incubators MIR-154 / MIR-254 / MIR-554 / MIR-162 / MIR-262

Microcomputer PID Control + Air Jacketed System Microcomputer PID control and air jacketed system givesprecise temperature control within the chamber.Temperature accuracy is within ±0,2°C (at 37°C) andtemperature uniformity is within ±1°C (at 37°C).

Microcomputer Timer Function An accurate microcomputer timer is fitted to allowexperiments up to 99 hours and 59 minutes. Desired start

time is set by an automatic start (delay function). Theprogram activates a buzzer when a set time is over andkeeps a set temperature after an operation finishes. Variousoperation patterns can be set by utilizing these functions.

Temperature Control Range- Ambient Temperature+5°C~80°C (AT 20°C) Panasonic heated incubators allow incubation at normaltemperature to high temperature.

Heated Incubators

Temperature pull-up speed: 20°C to 60°C Approx. 70 minutes.(ambient temperature 20°C, no load)

700

420

80

555

538

918 10

18

620580450

386

200

10 24

28

700

580450

200

260

858

386

1155

107580

0

200

1518

100

150

10620

28

24

43

42

800 832

640550

800

1240 11

60

1110

200

410

1400

1810

10 10

6

24 60

200

405

Unit: mm

480

350

Access port

375

575

21

100

37

548

310

Front view Side view

580595

820

82059

0

450

55

50

95.5

P30

x11=

330

P30x

11=3

30

195

2510

540 475

450

730600475

46012

690

870 64

019

525

1012

870 50

080

95.5 525

64550525

510

MIR-154 MIR-254 MIR-553

Dimensions

368

65

30 580450

200

555

538

13700620

200

1018

91

828

420

80 1

00

200

26

0

42

43

368

65

11

55

858

30 58045013

620700

80

01

50100

15

18

28

200

Unit: mm

135

Cooled and Heated Incubators MIR-154 / MIR-254 / MIR-554 / MIR-162 / MIR-262

Advanced Design Control panel uses a touch keyboard and an easy-to-read green LED display. Temperature and timeare shown respectively by digital displays. Durablestainless steel (SUS-304) for interior cabinet.

700

420

80

555

538

918 10

18

620580450

386

200

10 24

28

700

580450

200

260

858

386

1155

107580

0

200

1518

100

150

10620

28

24

43

42

800 832

640550

800

1240 11

60

1110

200

410

1400

1810

10 10

6

24 60

200

405

Unit: mm

480

350

Access port

375

575

21

100

37

548

310

Front view Side view

580595

820

82059

0

450

55

50

95.5

P30

x11=

330

P30x

11=3

30

195

2510

540 475

450

730600475

46012

690

870 64

019

525

1012

870 50

080

95.5 525

64550525

510

Performance data MIR-162 / MIR-262

MIR-162 MIR-262

Unit: mm

MIR-16293 LITRES

MIR-262153 LITRES

136

The Panasonic MIR-S100 orbital shaker delivers superior performance and

functions in a compact, low-vibration design.

l Low vibration, low noise

l Compact design, intelligent operation

l Easy installation in Panasonic incubator or growth chamber

Compact & High-Speed Orbital Shaker

MIR-S10050 TO 500 RPM

Name: Elena Terzic

Location in our network:

Sales Representative Panas

onic

Biomedical products at Hem

tek,

Serbia Montenegro

Favourite place:

Kalemegdan fortress, Belgr

ade

is built were the Sava and

Danube become one river

Belgrado, Serbia Montenegro

44º49’.26.98”N 20º27.03.78”E

Orbital Shaker MIR-S100 / MIR-S100C

BIOMEDICAL NETWORK - LISB

ON -

BIOMEDICAL NETWOR

K -

LATVIA - BIOMEDICAL NETW

ORK -

ISRAEL -

BIOMEDICAL N

ETWORK - CROATIA -

BIOMEDICAL NETWORK - EST

ONI

A -

BIOMEDICAL - CZECH REPUB

LIC

-

BIOMEDICAL NETWORK - ICE

LAN

D - BIOMEDICAL -BOSNIA HERZEG

OVNIA-

BIOMEDICAL NETWOR

K -

CYPRUS- BIOMEDICAL NETWORK - BUL

GARIA -

BIOMEDICAL SERBIA & MONTE

NEGRO

BIOMEDICAL NETWORK - GEO

RGI

A -

BIOMEDICAL NETWORK - FINL

AND -

BIOMEDICAL NETWOR

K - SLOVENIA-

137

High-speed ShakingThe MIR-S100 offers high-speedshaking from 50 to 500 rpm, whichsignificantly reduces waiting time forcultures.Easy Operation with MIR/MLR models Can be installed in the MIR-154/254/554and MLR-352. Control panel located incenter of unit enables checking ofindicators through the window of theMIR/MLR.Soft StartGradually accelerates until reaching thepreset number of revolutions so thatsamples inside flasks and test tubes are

not spilled or foamed. Three levels ofacceleration speed can be selected.Timer Indicates time of operation from 0 to99.9 hours in increments of 0.1 hour (6minutes).Integrated Operating Time DisplayDisplays the integrated operating time(which can be checked in the functionmode).Key LockLocks the keys on the control panel toavoid accidental function selection.Auto Recovery after PowerInterruptionAutomatically recovers after power

interruption, and indicates that powerinterruption has occurred.Speed Error AlarmIndicates an error when the number ofrevolutions does not reach or exceedsthe preset value.Motor Overload Protection CircuitDetects over-current and automaticallystops operation. Indicates an error whenoverload is applied to the motor.Sturdy Stainless Steel Finish Equipped with a cover made ofstainless steel with hair line finish tofacilitate cleaning.

No. of units that can be installedMIR-154 1 unitMIR-254 2 unitsMIR-554 2 unitsMLR-352 2 units

* The optional Mounting Kit is required forinstallation.

* Please refer to the instruction manual fordetails before use.

Revolution number/timedisplay unit

Numeric valueshift key ENT key

START/STOP key START/STOP key

SET key

RPM indicator lamp

TIME indicator lamp

Digit shift key

Orbital Shaker MIR-S100 / MIR-S100C

138

l Usable in a CO2 incubator.

l Controller and shaker sections are separated to

prevent humidity from affecting electrical components.

l Copper alloy stainless steel is used for the shaker

section.

l Revolution speed is from 40 to 200 rpm.

l Best suited to operation in a Panasonic CO2

incubator.

Compact orbital shaker for culture incubationin high humidity conditions

Orbital Shaker MIR-S100 / MIR-S100C

Shaking platform MIR-38PFNThreaded hole diameter: 10 – 32UNFThreaded hole pitch (longitudinal): 34.85 mmThreaded hole pitch (lateral): 20.65 mm

Test tube rack for various tubes MIR-204SC Mounting kit MIR-15FP for use with MIR-154/254/554 and MLR-352

Clamps for flasksMIR-51FC for 50 ml flaskMIR-101FC for 100 ml flaskMIR-201FC for 200 ml flaskMIR-301FC for 300 ml flaskMIR-501FC for 500 ml flaskMIR-1001FC for 1000 ml flaskMIR-2001FC for 2000 ml flask

Options MIR-S100 / MIR-S100C

Unit : mm

Front view

Side viewSide view

Rear view

Top view

Front view

Rear view

Top view

275

365

106

48

93

373

365

8 85

275

380

250

8 28

6

409

118

983

7

20

Shaker Controller

139

Structural DesignAntibacterial copper alloy stainless steel is used forthe shaker section. Also, the shaker section isequipped with a small window that can be used forspraying disinfectant inside. Soft StartGradually accelerates until reaching the presetnumber of revolutions so that samples inside flasksand test tubes are not spilled or foamed. Threelevels of acceleration speed can be selected. TimerIndicates time of operation from 0 to 99.9 hours inincrements of 0.1 hour (6 minutes). Auto Recovery after Power InterruptionAutomatically recovers after power interruption andindicates that power interruption has occurred. Speed Error AlarmIndicates an error when the number of revolutionsdoes not reach or exceeds the preset value. Motor Overload Protection CircuitDetects over-current and automatically stopsoperation. Indicates an error when overload isapplied to the motor. Maintenance-required Indicator Automatically alerts you when maintenance isrequired or when bearings and belts need replacingafter operational hours exceed 10,000.

MIR-S100C40 TO 200 RPM

Orbital Shaker MIR-S100 / MIR-S100C

Dimensions MIR-S100

Front view Rear viewTop view

Power cordattachment position

80

67

120

85 5

20

10

250

380

30 Power cord

305

410

Dimensions MIR-S100

Dimensions MIR-S100C

Unit: mm

l Autoclavesl Laboratory Autoclavesl Laboratory Ovensl Dry Heat Sterilizers

140140

Vision on Sterilisation

Panasonic recognizes that in order to excel you must be strong, focused and balanced. We focus on that vision by creating equipmentthat strikes a strong balance between cost and materials, design andusability. So that you can focus on accomplishing your goals. You andPanasonic a perfect match.

Portable Laboratory Autoclaves - Accurate,efficient temperature control. Easy-to-usefunctions. Portability so these Autoclaves go withyou, wherever that may be. Above all these Autoclaves feature a wealth of security features toensure the safety of the user and the materialinside. What more could you want from anAutoclave! With generous capacities of up to 12 1000mlflasks (MLS-3781L) and sterilisation temperaturesup to 135°C, we give you two important reasonswhy your next autoclave should be a Panasonicautoclave.For safe use of our new MLS-37 series,precautions and operating instructions are givenby voice guidance. The working conditions, that

are shown on the control panel, can be printed bya optional line thermal dot printer for record-keeping, management and storage. Two ranges ofportable Autoclaves designed for the individuallaboratory or user.

MOV Laboratory Ovens - Panasonic has alwaysaimed to provide research support equipment thatoffers complete satisfaction to suit its users.Inspired by the search for even higher precisionand greater flexibility of control, Panasonicpresents the MOV series of Laboratory Ovens;accurate, high-temperature equipment for scientificresearch.

68º24’.58.02”N 13º56’.31.44”E

Lofoten, Norway

Name: Peter JoyceLocation in our network:Area Manager Norwayfavourite place: The north of NorwayBIOMEDICAL NETWORK - D

ENMA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

142

Researchers waste valuable time and energy when limited to using a centralized buildingautoclave. Installation and maintenance of central autoclaves are not only costly but timeconsuming. Panasonic offers two solutions: The MLS-3781L and MLS-3751L portableautoclaves are designed for individual lab use and can be conveniently wheeled from onelab to another. Model MLS-3751L has a low enough profile to be stored under a lab benchwhen not in use.

Surprisingly Large ChamberDespite the compact outer dimensions of theseautoclaves, they store 8 (MLS-3751L) or 12 (MLS-3781L) 1,000ml flasks. The MLS-3751L has twobaskets, and the larger MLS-3781L has three.

Compact Design, Swing-up Lid for Easy AccessBoth Panasonic models can be easily installed inminimal space. A swing-up lid provides effortlessaccess for loading and unloading test tubes, flasks andlab instruments.

Autoclaves MLS-3751L / MLS-3781L

Compact design In-Lab Autoclaves

MLS-3751L50 LITRES

MLS-3781L75 LITRES

143

Autoclaves MLS-3751L / MLS-3781L

1. SterilizingFor water, culture media, reagents and other fluids. After completion and cooling to a selectedtemp., air is expelled automatically through theexhaust valve.

2. Sterilizing/Keep WarmAfter sterilizing culture media, reagents and otherliquids, and cooling down naturally to a selectedtemp., air is expelled automatically from the exhaust valve. High temp. prevents solidifying.

3. Melting/Keep WarmTo melt or keep culture media at a fixed temp.(This function is not for sterilizing but prevents solidifying).

4. Instrument SterilizingFor flasks, beakers, test tubes, other lab instru-ments. When completed, the exhaust valveopens and the temp. drops to 100°C. Thus, cooldown period can be shortened. Suitable forequipment that can withstand sharp drops inpressure and for sterilizing waste.

Sterilizing temp.: 115°C to 135°CTimer: 1 to 300 min.Exhaust temp.: 0°C to 45°C.

Sterilizing temp.: 115°C to 135°CTimer: 1 to 300 min.Exhaust temp.: 0°C to 45°CIncubation temp.: 45°C to 60°C.

Melting temp.: 60°C to 114°CTimer: 0 to 300 min., 72 hrs.Incubation temp.: 45°C to 60°C

Sterilizing temp.: 115°C to 135°CTimer: 1 to 300 min.

Setting example

Cycle Program Steriliz. Steriliz. Heat-retent.Temp. Time Temp.

1. Sterilizing 121˚C 27 min. –

2. Sterilizing/Keep Warm 121˚C 27 min. 50˚C

3. Melting/Keep Warm 100˚C 30 min. 50˚C

4. Instrument Sterilizing 135˚C 3 min. –Newly designed handle lets users open and close the lideasily with one hand.The conventional slide handle has been completelyredesigned to develop a hand-pull system that enables easyopening/closing by gripping with one hand. In addition, thecover is equipped with a scalding prevention guard toprevent scalding due to steam.

Equipped with 4 selectable courses and 3 customizableprogramsAny of 4 courses can be selected according to the purposeof use, and 3 types of setting values can be stored for eachcourse according to the usage conditions. The setting values(sterilizing temperature, sterilizing time, melting temperature,melting time, keep warm, exhaust temperature, exhaust rate)for each program can be easily changed by the user for easyuse.

Handle

Scaldingprevention guard

45º17’.49.59”N 6º35’.02.04”E

Name: Crijn Sprinkhuizen

Location in our network:

Export Manager of Panasonic

Biomedical Sales Europe B.V.

and therefore the main conta

ct

with Panasonic’s European

distributors.

favourite place:

The location in Europe I lik

e

most is the view from the to

p

of Cime de Caron in Val

Thorens, Les trois vallees,

France.

Val Thorens, France

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K -

AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSI

A -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

144

Autoclaves MLS-3751L / MLS-3781L

MLS-3751/3751L

Unit: mm

MLS-3781/3781L

103

129

65 6671

75

159

632478

420

965

900

335 48

0

673

426

607

1445

689

748

103

129

683

65

478

335

480

673

42666

607

632

159

420

1230

75

71

Process operation

0 10 20 30 40 50 62 70 80 84 90 105 0

75

100

120(˚C)

(min.)

Example: Instrument sterilisation course (Operating conditions: No load; Ambient temperature: 20°C;Sterilizing temperature: 121°C, Sterilizing time: 20 min.)

MLS-3751LMLS-3781LMLS-3750*MLS-3780**Our company’s previous models

• Operating time varies depending on operating conditions.

• For liquid sterilisation course, the operating time will be longer than for instrument sterilisation course.

Process operation

Functions for user safety and cooling fan/exhaust leveladjustment to reduce cooling time.Conforming to the requirements of IEC standards, whenusing sterilizing liquid the temperature when opening thecover is set to 65°C or less. In addition, by adding exhaustholes at several positions on the side of the product andpositioning the standard-equipment cooling fan under thechamber, cooing efficiency and sterilizing efficiency areincreased, so that operating time can be reduced. Furthermore, a constant open/close interval (with 5-step adjustment) for the exhaust process valve enables selectionof the exhaust rate for steam inside the chamber to enablecooling in a shorter time while reducing exhaust time andpreventing boiling over of sterilizing liquid.

Thermal printer (optional)The work conditions shown on the control panel (temperature/pressure inside chamber, sterilizing course,time) can be printed out by a line thermal dot printerfor record-keeping, management, and storage.

Microprocessor temperature controlSterilizing temperature is controlled to within +2°C/-0°C ofthe set temperature in the range of 115°C to 135°C.

Air vent control Can be set to allow automatic release after sterilizing iscompleted.

Options

Object temperature sensor MLS-37SB

Printer (with 1 roll of paper) MLS-37PR

Printer paper MLS-37PR-S (5-roll set)

Stainless Steel Baskets and Buckets inner dims.

Wire Baskets MLS-37BL ø335 x 220

MLS-37BS ø335 x 170

Solid Bucket MLS-37C30 ø330 x 300

Perforated Buckets MLS-37PB30 ø330 x 300

MLS-37PB40 ø330 x 400 (MLS-3781L only)

145

Autoclaves MLS-3751L / MLS-3781L

MLS-3751/3751L

Unit: mm

MLS-3781/3781L

103

129

65 6671

75

159

632478

420

965

900

335 48

0

673

426

607

1445

689

748

103

129

683

65

478

335

480

673

42666

607

632

159

420

1230

75

71

Process operation

0 10 20 30 40 50 62 70 80 84 90 105 0

75

100

120(˚C)

(min.)

Example: Instrument sterilisation course (Operating conditions: No load; Ambient temperature: 20°C;Sterilizing temperature: 121°C, Sterilizing time: 20 min.)

MLS-3751LMLS-3781LMLS-3750*MLS-3780**Our company’s previous models

• Operating time varies depending on operating conditions.

• For liquid sterilisation course, the operating time will be longer than for instrument sterilisation course.

MLS-3751L

Dimensions

MLS-3751/3751L

Unit: mm

MLS-3781/3781L

103

129

65 6671

75

159

632478

420

965

900

335 48

0

673

426

607

1445

689

748

103

129

683

65

478

335

480

673

42666

607

632

159

420

1230

75

71

Process operation

0 10 20 30 40 50 62 70 80 84 90 105 0

75

100

120(˚C)

(min.)

Example: Instrument sterilisation course (Operating conditions: No load; Ambient temperature: 20°C;Sterilizing temperature: 121°C, Sterilizing time: 20 min.)

MLS-3751LMLS-3781LMLS-3750*MLS-3780**Our company’s previous models

• Operating time varies depending on operating conditions.

• For liquid sterilisation course, the operating time will be longer than for instrument sterilisation course.

MLS-3781L

Wire Baskets Solid Bucket Perforated Bucket

ø370mm

ø370mm

ø370mm

ø370mm

ø370mm

MLS-3751L Load example

MLS-3781L Load example

Eight 1000ml flasks

Twelve 1000ml flasks

146

Laboratory Autoclaves MLS-2420U / MLS-3020U

Panasonic laboratory autoclaves provide a safe, reliablehigh pressure steam sterilizing environment within a unitthat is particularly easy to use. Microprocessor controlensures that the correct temperature is accurately maintained and easily operated with one-touchoperation. Fail-safe functions ensure user safety and thecompact design maximises use of valuable laboratoryspace. These reliable, energy saving autoclaves areideal for a wide range of applications.

Microprocessor control maintains accurate sterilisation temperature.A microprocessor monitors and controls the steam temperature within the chamber, ensuring that it is maintained within the range 105ºC - 126ºC.

Easy to operate ergonomic designThe interior of the chamber is free of protrusions suchas sensors or piping joints that could interfere with the

Accurate sterilisation temperature control - easy to use

The importance of sterilisation is growing in the field of good laboratory practice in areassuch as biotechnology and medicine. Of all sterilisation methods, the use of high pressure steam (autoclave) is the most widely used because of its efficacy, speed andreliability. This method is suitable for a wide range of applications including culturemedia, glass and metal implements, and waste products.

MLS-3020U48 LITRES

MLS-2420U20 LITRES

55º45.20.83”N 37º37’.03.48”E

Name: Ekaterina E. AbramovaLocation in our network:General director, AWT. Our company distributes Panasonic products in Russiafor many years.

favourite place: Moscow. Scientific,cultural and business capitalof our country. Moscow is avery beautiful city with a rich history.

Moscow, Russia

BIOMEDICAL NETWORK - DEN

MA

RK -

BIOMEDICAL NETWOR

K -

HUNGARY -

BIOMEDICAL NETWOR

K -

GERMANY-

BIOMEDICAL NETWOR

K - AUSTRIA -

BIOMEDICAL

N ETWORK - SWEDEN -

BIOMEDICAL NETWORK NETH

ERLANDS

BIOMEDICAL NETWORK -

UK -

BIOMEDICAL NETWORK - NOR

WA

Y - BIOMEDICAL NETWORK - TUR

KEY

-

BIOMEDICAL NETWOR

K - ESPANA- BIOMEDICAL NETWORK SWITZ

ERL

AND

BIOMEDICAL NETWORK - RU

SSIA -

BIOMEDICAL NETWORK - GREE

CE -

BIOMEDICAL NETWORK - MA

LTA -

BIOMEDICAL NETW

ORK

- ITALY-

Laboratory Autoclaves MLS-2420U / MLS-3020U

insertion or removal of items. The single rectangular handleturns easily and securely seals the chamber. The controlpanel is mounted at the top of the unit, making it easier tosee and operate. A water outlet valve allows easy changeover of thesterilisation water.

Digital controls and display eliminate setting errorsThe digital control panel allows temperature and time settings to be entered accurately in 1ºC and 1-minute intervals. The display panel is easy to read helping to prevent errors when setting parameters. Pressing the(TEMP) and (TIMER) keys simultaneously displays theremaining sterilisation time.

Safety assured with fail-safe functions1. Dry scorch protection function

Should the water level drop too low, an overheating protection circuit is triggered, a buzzer sounds and anerror message appears on the display. Buzzer alert: pairsof short beeps repeated in succession.

2. Door switchA safety mechanism prevents the autoclave fromoperating if the door is not completely closed. A doorclosed lamp lets you check whether the door is closed.

3. Pressure safety valveA reliable pressure safety valve is used to prevent the pressure inside the chamber from rising aboveacceptable levels.

4. Thermistor error detector functionIf the thermistor temperature sensor goes open circuit (connection broken), the heater turns off to preventoverheating. Buzzer alert: pairs of short beeps repeatedin succession.

5. Overheating protection functionThe digital display starts to flash if the temperature in thechamber rises more than 2ºC above the temperaturesetting. If it rises 3ºC or more above the setting, the relayshuts off and cuts off power to the heater.

6. Door protection functionIf the magnet-holder is not connected to the switchbutton, the high pressure lamp will flash when thetemperature inside the chamber is over 99ºC.

147

148

Audible and visual alarms alert the user to end ofcycle and error conditions.The unit sounds a buzzer to alert the user to any errorconditions requiring attention and to the end of the sterilisation cycle so that items can be removed fromthe autoclave.1.Sterilisation finished alert functionA buzzer sounds to tell you when sterilisation isfinished.

2.Safe to open door alert functionThe unit continues to monitor the temperature insidethe chamber after sterilisation is finished. Once theautoclave has cooled to the point where it is safe toopen the door, a buzzer sounds.

3. Safe to remove contents alert function(cycle fully complete)When the items being sterilized have cooled down tothe point where it is safe to remove them, a buzzersounds.

Compact design ideal where space is limited.The body of the unit, with its built in exhaust bottle,measures a mere 380 x 490 mm (MLS-2420U) and

440 x 550 mm (MLS-3020U) so it will fit in the tightestspaces.

Features of MLS-3020U/2420U.l Wide variety of items can be autoclaved using 126ºC

sterilisation.l The pressure vessel is designed to meet the ASME

safety code. In accordance with the code, these unitshave a lid interlock function.

Name: Yury A. Volodin

Location in our network:

commercial director AWT, Rus

sia

favourite place:

Moscow, Our capital combines

the architectural and

historical monuments, theate

rs,

museums, parks and recreatio

nal

areas and modern business

centers. Moscow is a city of

opportunity for

all.

BIOMEDICAL NETWOR

K - DENMARK -

BIOMEDICAL

NETWORK - HUNGARY -

BIOMEDICAL

NETWORK - GERMANY-

BIOMEDICAL

NETWORK - AUSTRIA -

BIOME

DICAL N ETWORK - SWEDEN -

BIOMEDICAL NETWOR

K NETHERLANDS

BIOMEDICAL NET

WORK - UK -

BIOMEDICAL NETWOR

K - NORWAY - BIOMEDICAL NETW

ORK - TURKEY-

BIOMEDICA

L N ETWORK - ESPANA-

BIOMEDICAL NETWOR

K S

WITZERLAND

BIOMEDICAL NET

WORK - RUSSIA - BIOMEDICAL NETW

ORK

- GREECE -

BIOMEDICAL NET

WORK - MALTA -

BIOMEDICA

L N ETWORK - ITALY-

Laboratory Autoclaves MLS-2420U / MLS-3020U

55º45.20.83”N 37º37’.03.48”E

Moscow, Russia

149

MLS-2420U MLS-3020U

Dimensions

380

490

440

550

Unit: mm

1050

840

380

490

440

550

Unit: mm

1050

840

Process operation

Laboratory Autoclaves MLS-2420U / MLS-3020U

Options

Special round basket, A (for MLS-2420U) MLS-RBA

Dimensions: 220(ø) x 215(H)mm

Special round basket, B (for MLS-3020U) MLS-RBB

Dimensions: 290(ø) x 215(H)mm

Special round basket, Half (for MLS-3020U) MLS-RBH

Dimensions: 290(ø) x 320(H)mm

42º38’.30.76”N 18º06’.23.33”E

Name: Robert Luksa

Location in our network:

Validation and calibration

specialist for Panasonic

equipment,also service engi

neer

for all Panasonic equipment

in

Croatia

favourite place:

Most beautiful place in Cro

atia

for me is Dubrovnik,because

it

is a very old town with ve

ry

rich past.Also with very

nice beaches,nature……

Dubrovnik, Croatia

BIOMEDICAL NETWORK - LISB

ON -

BIOMEDICAL NETWOR

K -

LATVIA - BIOMEDICAL NETW

ORK -

ISRAEL -

BIOMEDICAL N

ETWORK - CROATIA -

BIOMEDICAL NETWORK - EST

ONI

A -

BIOMEDICAL - CZECH REPUB

LIC -

BIOMEDICAL NETWORK - ICE

LAN

D - BIOMEDICAL -BOSNIA HERZEG

OVNIA-

BIOMEDICAL NETWOR

K -

CYPRUS- BIOMEDICAL NETWORK - BUL

GARIA -

BIOMEDICAL SERBIA & MONTE

NEGRO

BIOMEDICAL NETWORK - GEO

RGI

A -

BIOMEDICAL NETWORK - FINL

AND -

BIOMEDICAL NETWOR

K -

SLOVENIA-

150

Laboratory Ovens MOV-112 / MOV-212 / MOV-112F / MOV-212F / MOV-112S / MOV-212S

Microprocessor PID temperature control system guarantees an accurate temperatureenvironmentThe microprocessor PID (Proportional, Integrated and Differential) temperature controlsystem ensures accurate inside temperature. With less offset or overshoot, precise controlis possible. This system provides the high-temperature environment that exactly meetsexperimentation requirements.

The MOV Series can be widely used for basic to applied experimentation in the areas ofscientific, industrial and environmental testing.

Sheathed heater ensures durability and safetyA sheathed heater is incorporated in the heater section. The heating element is wrapped ina magnesium oxide insulating material and covered with a metal protection tube. Withconventional wire heating elements, gases or dust can cause corrosion, resulting in loss ofheating capacity and electrical leakage. With its durability and high chemical resistance, thesheathed heater ensures safer, more stable operation without the risk of electrical leakage.

Accurate, High-Temperature Equipment for Scientific Research

Panasonic has always aimed to provide research support equipment that offers com-plete satisfaction to its users. Inspired by the search for even higher precision andgreater flexibility of control, Panasonic presents the MOV Series.

Metal protection tube

Inorganic dust insulator(magnesium oxide)

Heating element (nickel chrome)

151

Laboratory Ovens MOV-112 / MOV-212 / MOV-112F / MOV-212F / MOV-112S / MOV-212S

Microprocessor timer function Panasonic has included a microprocessor timer function, sooperated times can be set up to a maximum of 99 hours and59 minutes. The combination of auto start and auto stopprovides operating patterns suited to a wide variety ofapplications. The auto stop operates the timer when theheater is on, or when the set temperature has been reached. A buzzer indicates the end of timer operation.

Attractive designPanasonic believes that laboratory equipment should beattractive as well as functional. The MOV Series features afuture-oriented design, with rounded corners, door handlesthat blend with the main body, and a flat control panel.

Alarm and safetyfunctions

Automatic settemperature alarm

Independentoverheatingprotection circuit

Overtemp. safetysystem for controlsection

Keylock switch

Memory backupfunction

Trigger

More than 10°C deviationfrom set temperature.

Abnormal temperatureincrease above upper limit.

Ambient temperature ofmain part (base) of control section exceeds65°C.

Keylock switch on.

During power failure,breaker cut or when unitis not connected to powersupply

Alarm notificationmethod and operation

Lamp, LED, buzzer.

While not in operation:buzzer.While in operation: lamp,LED and buzzer.Independent circuitswitches off heater and fanmotor.

Lamp, LED, buzzer.Heater and fan motorswitched off.

Key input not possible(excl. buzzer and call key).

Stores operation patternsfor set temperatures/times.

Alarm and safety functionsA comprehensive range of alarmand safety devices is included asstandard in the MOV Series.

MOV-212157 LITRES40˚C~250˚C

MOV-11297 LITRES40˚C~250˚C

152

Laboratory Ovens MOV-112 / MOV-212 / MOV-112F / MOV-212F / MOV-112S / MOV-212S

Performance data MOV-112F / MOV-212F / MOV-112 / MOV-212 / MOV-112S / MOV-212S

MOV-112F/S MOV-212F/SMOV-212MOV-112

User-oriented design for easy operationThe control panel has soft-touch keys and bright, greendigital LED display that allows easy confirmation oftemperature and remaining operation time. Other advantages of the design include a soft-latcheddoor handle integrated with the door, an observationwindow for checking conditions inside the cabinet, twoexhaust vents (shared with an access vent) on the top ofthe unit, and a stainless-steel (SUS-304) interior toguarantee durability and superior resistance to chemicals.

Malfunction Monitor (Self diagnosis function)Should a malfunction occur, it is diagnosed andindications are given on the digital display.

Built-in microprocessor timer guarantees accuratesterilisation timeThe built-in microprocessor timer (max. setting 99 hoursand 59 minutes) accurately adjusts sterilisation time. Aconsecutive display of the inner cabinet temperature isprovided for quick confirmation of the time when

MOV-112FMOV-112S90 LITRES40˚C~200˚C

153

Laboratory Ovens MOV-112 / MOV-212 / MOV-112F / MOV-212F / MOV-112S / MOV-212S

450

450

Dimensions MOV-112F/S MOV-212F/S

samples should be removed. And a buzzer sounds at theend of timer operation. In combination with auto start andauto stop, operation patterns can be set for a wide range ofapplications.

Natural convection system (MOV-112/MOV-212)Natural convection is best for drying very small samples andfine particles which would be scattered by a fan. This systemcan be used for high-temperature applications up to 250°C.

Forced air circulation system (MOV-112F/MOV-212F/MOV-112S/MOV-212S)Sirocco fan circulation keeps variations in inner cabinettemperature within ±4°C at 200°C. Compared with naturalconvection, quicker drying is possible. And Panasonic’sunique fan motor not only circulates hot air in the cabinet butalso keeps the motor cool, improving the reliability andsafety of the motor.

note: The size of the MOV-112/212 is 25mm deeper, due to the fact that these models use a natural convection system.

Unit: mm

MOV-212FMOV-212S150 LITRES40˚C~200˚C

154

Specifications all Biomedical Products

155

notes:1) Air temperature measured at freezer centre, ambient temperature +30°C, no load2) Requires Recorder MTR-155H3) Requires Sensor Cover MTR-C84) Requires Mounting Plate MDF-UBK5) CVK-A may also be used6) Exterior dimensions of main cabinet only - see dimension drawings showing handles and other external projections 7) Nominal Value

MODELDimensionsExternal dimensions (W x D x H)6)

Internal dimensions (W x D x H)VolumeNet weight (approx)PerformanceCooling performance 1)

Temperature setting rangeTemperature control range 1)

ControlController

DisplayTemperature sensorRefrigerationRefrigeration system

High-stage compressorHigh-stage refrigerantLow-stage compressorLow-stage refrigerantInsulation materialInsulation thicknessAlarmsPower failureHigh temperatureLow temperatureFilterLid / door openConstructionExterior materialInterior materialInner door/lidOuter door/lid lockShelvesMax. load - per shelfMax. load - totalAccess port- position- diameter

CastersElectrical and Noise LevelPower supplyNoise level 7)

OptionsSee page 161 for Inventory RacksDrawersSmall inner door kitTemperature recorders- Circular type- Continuous strip type- Recorder housing (if required)RS485 interface moduleLiquid CO2Back-upLiquid N2 Back-up

Specifications ULT Freezers

mm

mm

litres

kg

°C

°C

°C

W

W

mm

qty

qty

kg

kg

qty

Ø mm

qty

dB

qtySet of 2

-150°C/-152°C Freezers

PUF = Rigid polyurethane foamed insulation

V = Visual alarmB = Buzzer alarmR = Remote alarm

GROUP

Characteristics

MDF-1156-PE

1400 x 800 x 945

500 x 450 x 572

128

265

-152

-125 ~ -155

-130 ~ -152

LED

Pt-100

Cascade

1100

HFC

1100

HFC Mixed

PUF

175

V-B-R

V-B-R

-

V-B

-

Painted steel

Aluminium

1

Y

-

-

300

1

left

40

6 (2 leveling feet)

61

-

-

MTR-155H

-

-

CVK-AT2 2,5)

CVK-ATN2 2)

MDF-1156ATN-PE

1400 x 800 x 945

500 x 450 x 572

128

272

-152

-125 ~ -155

-130 ~ -152

LED

Pt-100

Cascade

1100

HFC

1100

HFC Mixed

PUF

175

V-B-R

V-B-R

-

V-B

-

Painted steel

Aluminium

1

Y

-

-

300

1

left

40

6 (2 leveling feet)

61

-

-

Supplied as standard

-

-

-

Supplied as standard

MDF-C2156VAN-PE

1730 x 765 x 1010

760 x 495 x 615

231

318

-150

-125~-152

-125 ~ -150

LCD

Pt-1000

Cascade with

auto-cascade

low-stage

1100

HFC

1100

HFC Mixed

PUF / VIP Plus

135

V-B-R

V-B-R

V-B-R

V-B

V-B

Painted steel

Aluminium

2

Y

-

-

207

1

right

40

6 (3 leveling feet)

51

-

-

MTR-155H

MDF-S30150

MTR-480

Supplied as standard

l Long-term storage below recrystallisation pointl Safe storage without risk of cross contaminationl Reliable Panasonic Cool Safe compressorsl Low operational costs

230V 50Hz Single

Microprocessor Non-volatile memory

notes:1) Air temperature measured at freezer centre, ambient temperature +30°C, no load2) Requires Recorder MTR-155H3) Requires Sensor Cover MTR-C84) Requires Mounting Plate MDF-UBK5) CVK-A may also be used6) Exterior dimensions of main cabinet only - see dimension drawings showing handles and other external projections 7) Nominal Value

MODELDimensionsExternal dimensions (W x D x H)6)

Internal dimensions (W x D x H)VolumeNet weight (approx)PerformanceCooling performance 1)

Temperature setting rangeTemperature control range 1)

ControlController

DisplayTemperature sensorRefrigerationRefrigeration system

High-stage compressorHigh-stage refrigerantLow-stage compressorLow-stage refrigerantInsulation materialInsulation thicknessAlarmsPower failureHigh temperatureLow temperatureFilterLid / door openConstructionExterior materialInterior materialInner door/lidOuter door/lid lockShelves (adjustable)Max. load - per shelfMax. load - totalAccess port- position- diameter

CastersElectrical and Noise LevelPower supplyNoise level 7)

OptionsSee page 161 for Inventory RacksDrawersSmall inner door kitTemperature recorders- Circular type- Continuous strip type- Recorder housing (if required)RS485 interface moduleLiquid CO2Back-upLiquid N2 Back-up

Specifications ULT Freezers

mm

mm

litres

kg

°C

°C

°C

W

W

mm

qty

qty

kg

kg

qty

Ø mm

qty

dB

qtySet of 2

VIP -86°C Upright & -80°C Chest Freezers

PUF = Rigid polyurethane foamed insulation

V = Visual alarmB = Buzzer alarmR = Remote alarm

GROUP

Characteristics

MDF-U33V-PE

670 x 867 x 1860

490 x 600 x 1140

333

255

-86

-50 ~ -90

-50 ~ -86

LED

Pt-1000

Cascade

450

HFC

750

HFC

PUF / VIP

70

V-B-R

V-B-R

V-B-R

V

V-B

Painted steel

Painted steel

2 (Insulated)

Y

3

50

150

3

Back/Bottom x 2

17

4 (2 leveling feet)

49

MDF-30R (Max 2)

MTR-G85

MTR-85H

MDF-S3085

MTR-480

CVK-UB2

CVK-UBN2

MDF-U55V-PE

770 x 870 x 1990

630 x 600 x 1380

519

290

-86

-50 ~ -90

-50 ~ -86

LED

Pt-1000

Cascade

450

HFC

750

HFC

PUF / VIP

70

V-B-R

V-B-R

V-B-R

V-B

V-B

Painted steel

Painted steel

2 (Insulated)

Y

3

50

150

3

Back/Bottom x 2

17

4 (2 leveling feet)

52

MDF-50R (Max 1)

MDF-5ID (Max 2)

MTR-G85

MTR-85H

MDF-S3085

MTR-480

CVK-UB2

CVK-UBN2

MDF-U74V-PE

1010 x 870 x 2010

870 x 600 x 1400

728

346

-86

-50 ~ -90

-50 ~ -86

LED

Pt-1000

Cascade

1100

HFC

1100

HFC

PUF / VIP

70

V-B-R

V-B-R

V-B-R

V-B

V-B

Painted steel

Painted steel

2 (Insulated)

Y

3

50

150

3

Back/Bottom x 2

17

4 (2 leveling feet)

51

-

MDF-7ID (Max 2)

MTR-G85

MTR-85H

MDF-S3085

MTR-480

CVK-UB2

CVK-UBN2

MDF-U76V-PE

1010 x 870 x 1990

870 x 600 x 1400

728

360

-86

-50 ~ -90

-50 ~ -86

LED

Pt-1000

Cascade

750

HFC

750

HFC

PUF/VIP PLUS

70

V-B-R

V-B-R

V-B-R

V-B

V-B

Painted steel

Painted steel

2 (Insulated)

Y

3

50

150

2

Back/Bottom x 1

17

4 (2 leveling feet)

49

-

MDF-7ID (Max 2)

MTR-G85

MTR-85H

MDF-S3085

MTR-480

CVK-UB2

CVK-UBN2

l Maximum storage capacity with Vacuum Insulation Panel technologyl Reliable Panasonic Cool Safe compressorsl Optimal sample securityl Superior performance and safe storage

230V 50Hz Single

Microprocessor Non-volatile memory

156

MDF-C8V1-PE

550 x 685 x 945

405 x 490 x 425

84

67

-80

-55~-85

-60 ~ -80

LED

Pt-1000

Auto-cascade

-

-

400

HFC Mixed

PUF / VIP Plus

70

V-B-R

V-B-R

V-B-R

Filterless design

-

Painted steel

Painted steel

1

Y

-

100

2

Back/Bottom

17

4 (2 leveling feet)

47

-

MTR-G85 3)

MTR-85H

MDF-S3085

MTR-480

CVK-UB4 4)

*Appearance and specification are subject to change without notice.

Dual-Cooling VIP -86°C Freezers -86°C Chest Freezers -86°C Upright Freezers

MDF-193-PE

750 x 700 x 945

480 x 430 x 420

86

103

-86

-50 ~ -95

-50 ~ -86

LED

Pt-100

Auto-cascade

-

-

450

HFC Mixed

PUF

135

V-B-R

V-B-R

V-B-R

Filterless design

-

Painted steel

Stainless Steel

1

Y

-

-

200

1

left

40

4 (2 leveling feet)

46

-

MTR-85H

-

-

CVK-A

-

MDF-394-PE

1860 x 800 x 945

1120 x 520 x 530

309

219

-86

-50 ~ -90

-50 ~ -86

LED

Pt-1000

Cascade

450

HFC

750

HFC

PUF

140

V-B-R

V-B-R

V-B-R

V-B

-

Painted steel

Stainless steel

3

Y

-

81

1

left

40

4 (3 leveling feet)

49

-

MTR-85H

-

-

CVK-UB2 5)

CVK-UBN2

MDF-594-PE

2010 x 770 x 1070

1280 x 500 x 762

487

291

-86

-20~-95

-20 ~ -86

LED

Pt-100

Cascade

1100

HFC

1100

HFC

PUF

135

V-B-R

V-B-R

-

V-B

-

Painted steel

Stainless steel

3

Y

-

-

234

1

left

40

4 (3 leveling feet)

50

-

-

MTR-85H

-

-

CVK-UB2 5)

CVK-UBN2

MDF-794-PE

2570 x 770 x 1070

1840 x 500 x 762

701

335

-86

-20~-95

-20 ~ -86

LED

Pt-100

Cascade

1100

HFC

1100

HFC

PFU

135

V-B-R

V-B-R

-

V-B

-

Painted steel

Stainless steel

4

Y

-

-

190

1

left

40

4 (3 leveling feet)

50

-

MTR-85H

-

-

CVK-UB2 5)

CVK-UBN2

MDF-U3386S-PE

750 x 875 x 1850

490 x 600 x 1140

333

255

-86

-50 ~ -90

-50 ~ -86

LED

Pt-1000

Cascade

450

HFC

750

HFC

PUF

130

V-B-R

V-B-R

V-B-R

V

-

Painted steel

Painted steel

2 (Insulated)

Y

3

50

150

3

Back/Bottom x 2

17

4 (2 leveling feet)

49

MDF-30R (Max 2)

MTR-G85

MTR-85H

MDF-S3085

MTR-480

CVK-UB2

CVK-UBN2

MDF-U4186S-PE

870 x 780 x 1975

620 x 515 x 1200

382

281

-86

-20 ~ -95

-20 ~ -86

LED

Pt-100

Cascade

1100

HFC

1100

HFC

PUF

125

V-B-R

V-B-R

-

V-B

V-B

Painted steel

Painted steel

2 (Insulated)

Y

3

50

150

1

left

40

4 (2 leveling feet)

49

-

-

MTR-85H

-

-

CVK-UB2

CVK-UBN2

MDF-U5386S-PE

890 x 867 x 1990

630 x 600 x 1280

483

305

-86

-50 ~ -90

-50 ~ -86

LED

Pt-1000

Cascade

1100

HFC

1100

HFC

PUF

130

V-B-R

V-B-R

V-B-R

V-B

-

Painted steel

Painted steel

2 (Insulated)

Y

3

50

150

3

Back/Bottom x 2

17

4 (2 leveling feet)

49

-

MTR-G85

MTR-85H

MDF-S3085

MTR-480

CVK-UB2

CVK-UBN2

MDF-U7386S-PE

1130 x 867 x 1990

870 x 600 x 1280

668

355

-86

-50 ~ -90

-50 ~ -86

LED

Pt-1000

Cascade

1100

HFC

1100

HFC

PUF

130

V-B-R

V-B-R

V-B-R

V

-

Painted steel

Painted steel

2 (Insulated)

Y

3

50

150

3

Back/Bottom x 2

17

4 (2 leveling feet)

49

-

MTR-G85

MTR-85H

MDF-S3085

MTR-480

CVK-UB2

CVK-UBN2

MDF-U700VX-PE

1010 x 870 x 2010

870 x 600 x 1400

728

383

-86

-50 ~ -90

-50 ~ -86

LCD

Pt-1000

"Independent

Dual-Cooling"

-

-

2 x 1100

HFC Mixed

PUF / VIP Plus

70

V-B-R

V-B-R

V-B-R

Filterless design

V-B

Painted steel

Painted steel

2 (Insulated)

Y

3

50

150

3

Back/Bottom x 2

17

4 (2 leveling feet)

53

MDF-7ID (Max 2)

MTR-G85

MTR-85H

MDF-S3085

MTR-480

CVK-UB2

CVK-UBN2

l Extreme secure Dual Cooling Systeml Evolutionary VIP PLUS insulationl Maximum sample securityl Energy saving ECO mode operation

l Ideal -86°C freezing environmentl Specially designed Panasonic Cool Safe compressorsl Microprocessor temperature control with digital designl Built-in temperature and power failure alarms

l Wide range of ULT freezers, to suit individual needsl Reliable Panasonic Cool Safe compressorsl Microprocessor temperature control for accuracy and reliabilityl Superior performance and safe storage

230V 50Hz Single

Microprocessor Non-volatile memory

Microprocessor Non-volatile memory

Microprocessor Non-volatile memory

230V 50Hz Single 230V 50Hz Single

157

MDF-U500VX-PE

770 x 870 x 1990

630 x 600 x 1380

519

320

-86

-50 ~ -90

-50 ~ -86

LCD

Pt-1000

"Independent

Dual-Cooling"

-

-

2 x 1100

HFC Mixed

PUF / VIP Plus

70

V-B-R

V-B-R

V-B-R

Filterless design

V-B

Painted steel

Painted steel

2 (Insulated)

Y

3

50

150

3

Back/Bottom x 2

17

4 (2 leveling feet)

53

MDF-50R (Max 1)

MDF-5ID (Max 2)

MTR-G85

MTR-85H

MDF-S3085

MTR-480

CVK-UB2

CVK-UBN2

notes:1) Air temperature measured at centre of unit, specified ambient temperature, no load2) Exterior dimensions of main cabinet only - see dimension drawings showing handles and other external projections 3) Nominal Value4) Will require recorder housing shown in (brackets).5) MDF-U537D - temperature can be independently set in upper and lower compartments

Specifications Medical Freezers

-30°C/-40°C Biomedical Chest Freezers

PUF = Rigid polyurethane foamed insulation

V = Visual alarmB = Buzzer alarmR = Remote alarm

GROUP

MDF-137-PE

640 x 687 x 881

525 x 440 x 715

138

52

-30

35

-18 ~ -35

-20 ~ -30

Electronic

LED

Thermistor

Direct

150

HFC

PUF

55

V-B-R

V-B-R

V-B-R

-

-

Painted steel

Coloured Aluminium

1

-

Y

-

-

2

10

50

2

right / bottom left

17

-

4 (2 leveling feet)

35

MDF-13B2, sets of two baskets

MDF-13B3, set of three baskets

MTR-G85

(MDF-S740)

MTR-4015LH

(MDF-S3040)

MTR-480

MDF-237-PE

905 x 687 x 881

790 x 440 x 715

221

60

-30

35

-18 ~ -35

-20 ~ -30

Electronic

LED

Thermistor

Direct

200

HFC

PUF

55

V-B-R

V-B-R

V-B-R

-

-

Painted steel

Coloured Aluminium

1

-

Y

-

-

3

10

80

2

right / bottom left

17

-

4 (2 leveling feet)

41

MDF-13B2, sets of two baskets

MDF-13B3, set of three baskets

MTR-G85

(MDF-S740)

MTR-4015LH

(MDF-S3040)

MTR-480

MDF-436-PE

1265 x 807 x 905

1140 x 550 x 735

426

71

-35

35

-18 ~ -40

-20 ~ -35

Electronic

LED

Thermistor

Direct

350

HFC

PUF

60

V-B-R

V-B-R

V-B-R

-

-

Painted steel

Coloured Aluminium

1

-

Y

-

-

4

10

110

2

right / bottom left

17

-

4 (2 leveling feet)

40

MDF-43B2, sets of two baskets

MDF-43B3, set of three baskets

MTR-G85

(MDF-S740)

MTR-4015LH

(MDF-S3040)

MTR-480

l Outstanding performance & reliability levell Power to cope with frequent lid openingsl From small "personal use" size to large 400 litre capacityl Low operational costs

MODELDimensionsExternal dimensions (W x D x H) 2)

Internal dimensions (W x D x H)

VolumeNet weight (approx)PerformanceCooling performance 1)

- at ambient temperatureTemperature setting rangeTemperature control range 1)

ControlControllerDisplayTemperature sensorRefrigerationCooling method

CompressorRefrigerantInsulation materialInsulation thicknessAlarmsPower failureHigh temperatureLow temperatureFilterLid/door openConstructionExterior materialInterior materialOuter door/lidInner door/lidOuter door/lid lockShelvesDrawersContainers / basketsMax. load - per shelf/basket/drawerMax. load - totalAccess port- position- diameterInterior fluorecent lampCastersElectrical and Noise levelPower supplyNoise level 3)

OptionsStorage systems

Temperature recorders 4)

- Circular type (recorder housing)

- Continuous strip type (recorder housing)

RS485 Interface Module

mm

mm

litres

kg

°C

°C

°C

°C

W

mm

qty

qty

qty

qty

qty (L/M/S)

kg

kg

qty

Ø mm

qty

qty

dB

230V 50 Hz Single phase

158

Characteristics

*Appearance and specification are subject to change without notice.** Picture shows optional containers and additional 3 shelves

MDF-U334-PE

614 x 709 x 1620

490 x 486 x 1290

274

81

-30

35

-18 ~ -35

-20~ -30

Micrprocessor

LED

Thermistor

Direct

200

HFC

PUF

60

V-B-R

V-B-R

V-B-R

-

-

Painted steel

Styrol resin

1

-

Y

Fixed

-

4/0/1

30

80

1

left

30

-

4 (2 leveling feet)

37

MTR-G85

(MDF-S740T)

MTR-4015LH

MTR-480

MDF-U5312-PE

804 x 772 x 1802

658 x 607 x 1272

482

134

-30

35

-20~ -30

-20~ -30

Micrprocessor

LED

Thermistor

Direct

400

HFC

PUF

70

V-B-R

V-B-R

V-B-R

-

-

Painted steel

Styrol resin

2

-

Y

Fixed

-

4/6/0

U:30\L:30

100

1

back

30

-

4 (2 leveling feet)

40

MTR-G85

(MPR-S7)

MTR-4015LH

(MPR-S30)

MTR-480

MDF-U537D-PE

804 x 772 x 1802

Upper: 658 x 607 x 589

Lower: 658 x 607 x 603

452

136

-30

35

-18 ~ -40

-20 ~ -30 5)

Electronic

LED

Thermistor

Direct

350

HFC

PUF

70

V-B-R

V-B-R

V-B-R

-

-

Painted steel

Styrol resin

2

-

Y

Fixed

-

0/6/8

U:30/L:20

100

2

back

30

-

4 (2 leveling feet)

42

MTR-G85

(L:MPR-S7,U:MDF-S740T)

MTR-4015LH

(L:MPR-S30)

MTR-480

MDF-U5412-PE

804 x 772 x 1802

658 x 607 x 1272

482

134

-40

30

-18 ~ -45

-20 ~ -40

Micrprocessor

LED

Thermistor

Direct

400

HFC

PUF

70

V-B-R

V-B-R

V-B-R

-

-

Painted steel

Styrol resin

2

-

Y

Fixed

-

4/6/0

U:30\L:30

100

1

back

30

-

4 (2 leveling feet)

42

MTR-G85

(MPR-S7)

MTR-4015LH

(MPR-S30)

MTR-480

MDF-U443-PE

800 x 832 x 1810

640 x 615 x 1090

426

213

-40

35

-15 ~ -44

-15 ~ -40

Micrprocessor

LED

Thermistor

Cascade +

Forced air circulation

H:400/L:750

HFC

PUF

80

V-B-R

V-B-R

V-B-R

V-B

V-B

Painted steel

Stainless steel

1

2

Y

5

-

-

50

200

1

left

40

1

4 (2 leveling feet)

51

-

MTR-85H or

MTR-4015LH

MTR-480

MDF-U731M-PE

770 x 830 x 1955

650 x 700 x 1520

690

152

-30

35

-18 ~ -35

-20 ~ -30

Micrprocessor

LED

Thermistor

Direct

400

HFC

PUF

60

V-B-R

V-B-R

V-B-R

-

V-B

Painted steel

Painted steel

1

-

Y

4

-

Optional

50

200

2

left/top

30

-

4 (2 leveling feet)

42

MDF-T07SC, Set of 2 containers

MTR-G85

(MPR-S7)

MTR-4015LH

(MPR-S30)

-

l Outstanding reliability and performancel Available for a wide variety of storage and research applications

l Excellent safety featuresl Maximum capacity in minimum installation space

230V 50 Hz Single phase

-30°C/-40°C Biomedical Upright Freezers

159

**

MODELDimensionsExterior (W x D x H)Interior (W x D x H)

Effective capacityWeightConstructionExterior finish

Interior finish

Outer doors

Inner doorsShelves

Drawers

- max. load/shelf or drawerCastorsAccess port- position- diameter

Refrigeration & TemperatureInsulation

Cooling method

Defrost method

RefrigerantTemperature control range

Temperature sensorTemperature controlOptions

Alarms

Temperature display

Specifications Refrigerators

mm

mm

litres

kg

qty

qty

qty

kg

qty

qty

Ø mm

°C

Refrigerators

MPR-721-PE

770 x 830 x 1955

650 x 710 x 1500

684

174

Acrylic finish baked on zinc

galvanised steel

Acrylic finish baked on zinc

galvanised steel

1 door, double pane glass,

self closing

-

4 wire shelves,

polyethylene-coated

-

50

4

3

2 in sides, 1 in cabinet top

30

HCFC-free rigid polyurethane

foamed-in-place

Forced air with single fan

Forced type (cycle defrost),

fully automatic

HFC

2 ~ 23

(AT 0°C - 35°C no-load)

Thermistor

Microprocessor

MPR-48B Power failure alarm

(audio-visual)

MTR-480 RS485 Interface

module (requires MPR-48B)

High/Low temperature,

door open,

power failure (option)

Remote alarm contact

DC 30V, 2A

Digital LED

MPR-721R-PE

770 x 830 x 1955

650 x 710 x 1500

671

193

Acrylic finish baked on zinc

galvanised steel

Acrylic finish baked on zinc

galvanised steel

1 door, double pane glass,

self closing

-

-

5 coated steel drawers

40

4

3

2 in sides, 1 in cabinet top

30

HCFC-free rigid polyurethane

foamed-in-place

Forced air with single fan

Forced type (cycle defrost),

fully automatic

HFC

2 ~ 23

(AT 0°C - 35°C no-load)

Thermistor

Microprocessor

MPR-48B Power failure alarm

(audio-visual)

MTR-480 RS485 Interface

module (requires MPR-48B)

High/Low temperature,

door open,

power failure (option)

Remote alarm contact

DC 30V, 2A

Digital LED

MPR-1411-PE

1440 x 830 x 1950

1320 x 710 x 1500

1364

248

Acrylic finish baked on zinc

galvanised steel

Acrylic finish baked on zinc

galvanised steel

2 doors, double pane glass,

self closing

-

8 wire shelves,

polyethylene-coated

-

40

4

3

2 in sides, 1 in cabinet top

30

HCFC-free rigid polyurethane

foamed-in-place

Forced air with double fan

Forced type (cycle defrost),

fully automatic

HFC

2 ~ 23

(AT 0°C - 35°C no-load)

Thermistor

Microprocessor

MPR-48B Power failure alarm

(audio-visual)

MTR-480 RS485 Interface

module (requires MPR-48B)

High/Low temperature,

door open,

power failure (option)

Remote alarm contact

DC 30V, 2A

Digital LED

MPR-1411R-PE

1440 x 830 x 1950

1320 x 710 x 1500

1359

287

Acrylic finish baked on zinc

galvanised steel

Acrylic finish baked on zinc

galvanised steel

2 doors, double pane glass,

self closing

-

-

10 coated steel drawers

40

4

3

2 in sides, 1 in cabinet top

30

HCFC-free rigid polyurethane

foamed-in-place

Forced air with double fan

Forced type (cycle defrost),

fully automatic

HFC

2 ~ 23

(AT 0°C - 35°C no-load)

Thermistor

Microprocessor

MPR-48B Power failure alarm

(audio-visual)

MTR-480 RS485 Interface

module (requires MPR-48B)

High/Low temperature,

door open,

power failure (option)

Remote alarm contact

DC 30V, 2A

Digital LED

MPR-514-PE

900 x 600 x 1790

800 x 465 x 1300

489

141

Baked-on acrylic finish

galvanised steel

Stainless steel

2 sliding doors, double layer

glass window with

heat reflecting film

-

5 wire shelves,

polyester-coated

-

50

4

1

left hand side

30

HCFC-free rigid polyurethane

foamed-in-place

Forced cool air circulation

Forced type, fully automatic

HFC

2 ~ 14

(AT -5°C - 35°C no-load)

Thermistor

Electronic

MPR-48B Power failure alarm

(audio-visual)

MTR-480 RS485 Interface

module (requires MPR-48B)

High/Low temperature,

door open,

power failure (option)

Remote alarm contact

DC 30V, 2A

Digital LED

160

Characteristics l Extremely stable and reliablel Speedy and powerful refrigeration

l Adjustable shelves or pull out drawersl Easy-to-manage lay out

Refrigerators Refrigerators Refrigerator with Freezer

MPR-514R-PE

900 x 600 x 1790

800 x 465 x 1300

486

147

Baked-on acrylic finish

galvanised steel

Stainless steel

2 sliding doors, double layer

glass window with

heat reflecting film

-

5 wire shelves,

polyester-coated

5 sliding racks,

polyester coated

20

4

1

left hand side

30

HCFC-free rigid polyurethane

foamed-in-place

Forced cool air ciculation

Forced type, fully automatic

HFC

2 ~ 14

(AT -5°C - 35°C no-load)

Thermistor

Electronic

MPR-48B Power failure alarm

(audio-visual)

MTR-480 RS485 Interface

module (requires MPR-48B)

High/Low temperature,

door open,

power failure (option)

Remote alarm contact

DC 30V, 2A

Digital LED

MPR-1014-PE

1800 x 600 x 1790

1700 x 465 x 1300

1033

246

Baked-on acrylic finish

galvanised steel

Stainless steel

2 sliding doors, double layer

glass window with

heat reflecting film

-

10 wire shelves,

polyester-coated

-

50

4

1

left hand side

30

HCFC-free rigid polyurethane

foamed-in-place

Forced cool air ciculation

Forced type, fully automatic

HFC

2 ~ 14

(AT -5°C - 35°C no-load)

Thermistor

Electronic

MPR-48B Power failure alarm

(audio-visual)

MTR-480 RS485 Interface

module (requires MPR-48B)

High/Low temperature,

door open,

power failure (option)

Remote alarm contact

DC 30V, 2A

Digital LED

MPR-1014R-PE

1800 x 600 x 1790

1700 x 465 x 1300

1029

258

Baked-on acrylic finish

galvanised steel

Stainless steel

2 sliding doors, double layer

glass window with

heat reflecting film

-

5 wire shelves,

polyester-coated

10 sliding racks,

polyester coated

50/20 (shelves/racks)

4

1

left hand side

30

HCFC-free rigid polyurethane

foamed-in-place

Forced cool air ciculation

Forced type, fully automatic

HFC

2 ~ 14

(AT -5°C - 35°C no-load)

Thermistor

Electronic

MPR-48B Power failure alarm

(audio-visual)

MTR-480 RS485 Interface

module (requires MPR-48B)

High/Low temperature,

door open,

power failure (option)

Remote alarm contact

DC 30V, 2A

Digital LED

MPR-161DH-PE

800 x 450 x 1090

720 x 300 x 725

158

59

Baked-on acrylic finish

galvanised steel

Stainless steel

2 sliding doors, double layer

glass window with

heat reflecting film

-

2 wire shelves,

polyethylene-coated

-

20

2

1

back side

30

Rigid polyurethane foam

Fan forced air circulation

Forced type (cycle defrost),

fully automatic

HFC

2 ~ 14

(AT: +35°C no-load)

Thermistor

Electronic

High/Low temperature,

door open

Digital LED

MPR-311DH-PE

800 x 450 x 1800

720 x 350 x 1435

340

90

Baked-on acrylic finish

galvanised steel

Stainless steel

4 sliding doors, double layer

glass window with heat

reflecting film

-

5 wire shelves,

polyethylene-coated

-

20

2

1

back side

30

Rigid polyurethane foam

Fan forced air circulation

Forced type (cycle defrost),

fully automatic

HFC

2 ~ 14

(AT: +35°C no-load)

Thermistor

Electronic

High/Low temperature,

door open

Digital LED

MPR-215F-PE

540 x 557 x 1794

455 x 466 x 917 (Ref)

420 x 342 x 267 (Frz)

176/39 (Ref/Frz)

80

Polyester resin finish baked

on zinc galvanized steel

Styrol resin/Painted alumi-

nium plate (Ref/Frz)

2

-

3/1 (Ref/Frz)

20/10 kg (Ref/Frz)

-

-

4

2

1 left/1 left (Ref/Frz)

30

CFC-free rigid polyurethane

foamed-in-placeFan forced air circulation (Ref)

Direct cooling (Frz)

-

HFC

2 ~ 14 (Ref) / -20 ~ -30 (Frz)

(AT: +30°C no-load)

Thermistor

Microprocessor

High/Low temperature,

power failure,

door open

Remote alarm contact

DC 30V, 2A

Digital LED

MPR-414F-PE

800 x 600 x 1805

720 x 495 x 1425 (Ref)

317 x 440 x 576 (Frz)

340/82 (Ref/Frz)

126

Polyester resin finish baked

on zinc galvanized steel

Stainless steel/Painted

aluminium plate (Ref/Frz)

4

-

2 large & 3 small/1 (Ref/Frz)

25 & 15 kg/15 kg (Ref/Frz)

-

4

2

1 rear/1 rear (Ref/Frz)

30

CFC-free rigid polyurethane

foamed-in-placeFan forced air circulation (Ref)

Direct cooling (Frz)

-

HFC

2 ~ 14 (Ref) / -20 ~ -30 (Frz)

(AT: +35°C no-load)

Thermistor

Microprocessor

High/Low temperature,

power failure,

door open

Remote alarm contact

DC 30V, 2A

Digital LED

161

*Appearance and specification are subject to change without notice.

l Stable and reliable environment controll Double sensor temperature managementl Remarkable cooling efficiencyl Automatic cycle defrosting system

l Stable and reliable environment controll Remarkable cooling efficiencyl Electronic temperature control systeml Fan-forced air circulation

l One unit with dual temperature zonel Superior cooling performancel Quiet operationl Various alarm and safety devices

*Appearance and specification are subject to change without notice.

Blood Bank RefrigeratorsGROUP

MBR-107DH-PE

400 x 495 x 1515

320 x 350 x 710

79

32 bags (450ml)

70

Baked-on acrylic finish

galvanised steel

Stainless steel

1, triple layer glass window

2, Acrylic

3, zinc plated steel wire &

1, stainless steel

-

20

-

1

left hand side

30

CFC-free rigid polyurethane

foamed-in-place

4 +/- 1 (AT 35°C)

Fully automatic

Forced air

HFC

Thermistor

Included

Microprocessor

High/Low temperature,

door open, power failure

Remote alarm contact

DC 24V 1A

230V 50Hz Single phase

Digital LED

Baskets;

MBR-15B, max. 8/unit

7 x 220ml bags/basket

MBR-16B, max. 8/unit

4 x 450ml bags/unit

MBR-506DH-PE

800 x 832 x 1810

640 x 550 x 1240

425

120 bags (450ml)

185

Baked-on acrylic finish

galvanised steel

Stainless steel

1, triple layer glass window

5, Acrylic

5, coated hard steel wire

-

50

4

1

left hand side

40

CFC-free rigid polyurethane

foamed-in-place

4 +/- 1 (AT 35°C)

Fully automatic

Forced air

HFC

Thermistor

Included

Microprocessor

High/Low temperature,

door open, power failure

Remote alarm contact

DC 24V 1A

230V 50Hz Single phase

Digital LED

Baskets;

MBR-55B, max. 20/unit

10 x 220ml bags/basket

MBR-56B, max. 20/unit

6 x 450ml bags/unit

MBR-704GR-PE

770 x 830 x 1955

650 x 697 x 1500

617

360 bags (450ml)

210

Baked-on acrylic finish

galvanised steel

Baked-on acrylic finish

galvanised steel

1, double layer glass window

3, Acrylic

-

6, Stainless steel

40

4

2

left & right hand side

30

CFC-free rigid polyurethane

foamed-in-place

4 +/- 1 (AT 35°C)

Fully automatic

Forced air

HFC

2 bottles with thermistor

sensor

MTR-G04 (Included)

Microprocessor

High/Low temperature,

door open, power failure

Remote alarm contact

DC 30V, 2A

230V 50Hz Single phase

Digital LED

MBR-1405GR-PE

1440 x 830 x 1950

1320 x 697 x 1500

1301

720 bags (450ml)

315

Baked-on acrylic finish

galvanised steel

Baked-on acrylic finish

galvanised steel

2, double layer glass windows

6, Acrylic

-

12, Stainless steel

40

4

2

left & right hand side

30

CFC-free rigid polyurethane

foamed-in-place

4 +/- 1,5 (AT 35°C)

Fully automatic

Forced air

HFC

2 bottles with thermistor

sensor

MTR-G04 (Included)

Microprocessor

High/Low temperature,

door open, power failure

Remote alarm contact

DC 30V, 2A

230V 50Hz Single phase

Digital LED

RS485 Interface module

MTR-480

mm

mm

litres

kg

qty

qty

qty

qty

kg

qty

qty

Ø mm

°C

MODELDimensionsExterior (W x D x H)Interior (W x D x H)Effective capacity

WeightConstructionExterior finish

Interior finish

Outer doors

Inner doors

Shelves

Drawers- max. load/shelf or drawer

CastorsAccess port- position- diameter

Refrigeration & TemperatureInsulation

Cooling performanceDefrost methodAir circulationRefrigerantTemperature sensor

Temperature recorderTemperature control Alarms

Power supply

Temperature display

OptionsInterface

Storage systems

MBR-305GR-PE

600 x 680 x 1835

520 x 490 x 1150

302

120 bags (450ml)

147

Baked-on acrylic finish

galvanised steel

Baked-on acrylic finish

galvanised steel

1, double layer glass window

2, Acrylic

-

5, Stainless steel

20

4

1

left hand side

30

CFC-free rigid polyurethane

foamed-in-place

4 +/- 1.5 (AT 35°C)

Fully automatic

Forced air

HFC

2 bottles with thermistor

sensor

MTR-G04 (Included)

Microprocessor

High/Low temperature,

door open, power failure

Remote alarm contact

DC 30V, 2A

230V 50Hz Single phase

Digital LED

RS485 Interface module

MTR-480

Baskets;

MBR-55B, MBR-56B

Specifications Blood Bank Refrigerators

162

Characteristics l Constant temperature control by two thermistor sensorsl Designed to conform AABB criteria

l Temperature chart recorder is standard built inl Excellent temperature uniformity

46º22’.00.07”N 14º06’.30.64”E

Name: Borut Repina

Location in our network:

Panasonic service specialist

at

Kemomed d.o.o., Kranj, Slove

nia

favourite place:

our beautiful place in Slove

nia

called Bled with Medieval ca

stle

on top of a cliff and a chur

ch in

the middle of the Lake benea

th

it.Bled is also known as one

of

the most beautiful places in

Europe and a must visit for

most

of the turists who come to

Slovenia.

Bled, Slovenia

BIOMEDICAL NETWORK - LISB

ON - BIOMEDICAL NETW

ORK -

LATVIA - BIOMEDICAL NETW

ORK -

ISRAEL -

BIOMEDICAL N

ETWORK - CROATIA -

BIOMEDICAL NETWORK - EST

ONI

A -

BIOMEDICAL - CZECH REPUB

LIC

-

BIOMEDICAL NETWORK - ICE

LAN

D - BIOMEDICAL -BOSNIA HERZEG

OVNIA-

BIOMEDICAL NETWOR

K -

CYPRUS- BIOMEDICAL NETWORK - BUL

GARIA -

BIOMEDICAL SERBIA & MONTE

NEGRO

BIOMEDICAL NETWORK - GEO

RGI

A -

BIOMEDICAL NETWORK - FINL

AND -

BIOMEDICAL NETWOR

K -

SLOVENIA-

Specifications Cryopreservation

164

Isothermal CarouselGROUP

MODELLiquid Nitrogen CapacityStatic Evaporation RateStatic Holding TimeDimensionsExternal dimensions (WxDxH)Usable interior height Usable interior diameter Weight emptyWeight fullMaximum CapacityMax. vial capacity (2ml)**Max. blood bag capacity (50ml)**

ltrltr/daysdays

mmmmmmkgkg

V-1500AB3056

660 x 939 x 1143736534148174

9100434

V-3000AB7098

939 x 1219 x 1206736787272327

221001120

V-5000AB93 118

1219 x 1371x 13207361016425500

403001936

V-5000ABEH1401112

1219 x 1371 x 14738641016453566

465002208

V3000-AB/C70

8

940 x 1219 x 1130686737272327

18000852

V3000EH-AB/C89

9

940 x 1219 x 1384889737288361

225001136

Isothermal -190˚C Dry Storage Freezers

** C

apac

ity is

sub

ject

to

rack

typ

e

l Outstanding temperature uniformityl No LN2 in sample storage area

l No cross contaminationl Certified MDD 93/42/EEC:1993 Class IIA

Characteristics

Standard LN2 FreezersGROUP

MODELLiquid Nitrogen CapacityStatic Evaporation RateStatic Holding TimeDimensionsExternal dimensions (WxDxH)Usable interior height Usable interior diameter Weight emptyWeight fullMaximum CapacityMax. vial capacity (2ml)**Max. blood bag capacity (50ml)**

ltrltr/daysdays

mmmmmmkgkg

S90-AB90

2.7533

457x 457x 96571140636109

5832266

S-1500AB145441

558x 787x 104173650870188

9100434

S-3000AB345749

863x 1092x 1066736787159438

221001120

S-5000AB615961

1117x 1320x12197361016227724

403001936

S-5000ABEH720980

1117x 1320x13978631016245827

465002208**

Cap

acity

is s

ubje

ct t

o ra

ck t

ype

l Outstanding temperature uniformityl Liquid level auto-fill

l Alarm system to provide securityl Custom configurations possible

Characteristics

MODELLiquid Nitrogen CapacityStatic Evaporation RateStatic Holding Time Working Volume Weight emptyWeight fullDimensionsNeck opening (mm) Overall height (mm) Outside diameter (mm) Canister DimensionsCanister height (mm) Canister diameter (mm) Maximum CapacityMaximum number of racksMaximum vial capacityMaximum number of canistersMaximum boxes per rackMaximum number of 1/2cc straws (10/cane) Maximum number of 1/2cc straws (1 level bulk)Maximum number of 1.2 & 2.0 mlvials (5/cane)AlarmLow-level alarm

ltrltr/daysdaysltrkgkg

mmmmmm

mmmm

qty

qty

Classic 200261

0.853851

26.382.5

216723559

--

42000

-5-

-

-

standard

Classic 40021210.9970

11136.7136

2161003559

--

44000

-10-

-

-

standard

Classic 60021750.9910416546.7193

2161003665

--

66000

-10-

-

-

standard

Value added200161

0.853861

26.382.5

216723559

--

42000

-5-

-

-

standard

Value added40011210.997011136.7136

2161003559

--

44000

-10-

-

-

standard

Value added60011750.9910416546.7193

2161003665

--

66000

-10-

-

-

standard

20/2020.50.09140

11.828.3

55.4652368

27941.9

--6-

780

1122

210

standard

34/1834.80.18123

15.443.5

89675464

27971

--6-

2100

3000

630

standard

47/1147.40.3976

16.454.6

127673508

279102

67506-

4500

6216

1320

standard

Classic Value added XC seriesGROUP

l Storage solutions foe vials and strawsl Easy access to store and retrieve samples

l Durable lightweight aluminium constructionl Capacities from 210 to 6.000 2ml vials

Characteristics

165

MODELLN2 CapacityStatic Evaporation RateStatic Holding TimeWeight EmptyWeight FullNumber of CanistersMax Vial Capacity (2ml)Unit DimensionsOverall HeightOutside DiameterNeck OpeningUsable interior DimensionsInterior HeightInterior DiameterCanister HeightCanister Diameter

SC 2/1 V1.5

0.198

2.7419

34318435

--

12731

SC 4/2 V3.60.261311171

106

46822270

--

27867

SC 4/3 V4.30.20211320148

49222251

--

27846

DS-3100.7143047-

500

584381216

317.5216

--

CF-951110.53.331332--

431.8254

228.6

228.6228.6

--

ltrltr/daydayskgkg

mmmmmm

mmmmmmmm

GROUP

Characteristics l For shipment of “non-hazardous” samplesl Protecting shipping carton available

l Made of lightweight durable aluminum

Vapor Shippers Shipper

*Appearance and specification are subject to change without notice.

Controlled Rate FreezerGROUP

ModelDimensionsExterior (W x D x H)Interior (W x D x H)Effective capacityWeightPowerVoltageFrequencyCurrentMaximum Capacity2ml vials4ml / 5 ml vialsBag CanistersCanes

mmmmlitreskg

Characteristics

2101

485 x 648 x 743243 x 349 x 356

2834.7

220 - 240V50 Hz10A

65039020

130

MODELLiquid Nitrogen CapacityStatic Evaporation Rate Static Holding Time Weight EmptyWeight FullMax. vial capacity (2ml)Exterior DimensionsNeck Opening Overall HeightOutside Diameter Overall opening Outside openingInterior DimensionsInterior DiameterUsable Height

Lab44

0.2182.76-

35.5426185

139198

Lab55

0.1533.3

48-

56463222

165266

Lab1010

0.1855.6

614-

26546260

210343

Lab2021

0.18116.7

926-

51627368

289348

Lab3032

0.251281238-

64611432

356378

Lab5050

0.451111556-

64779432

356559

ltrltr/daysdayskgkg

mmmmmmmmmm

mmmm

Lab tanksGROUP

Characteristics l For LN2 transportl High efficiency super insulation

l Easy to liftl Withdrawel device available

notes:1) MCO-18, 19 and 5 series can only be fitted with one communications terminal2) Nominal Value3) Includes humidifying pan cover and water level sensor4) ±0.25°C; ambient temp 25°C, settings 37°C, CO2 5%, O2 5% (Multigas), no load5) Not Applicable6) MCO-21SB is required for stacking with the MCO-19 series or MCO-18AC7) Requires SafeCellTM UV option

MODELDimensionsExternal dimensions (W x D x H)Internal dimensions (W x D x H)volumenet weightTechnical DataPower supplyFrequencyNoise Level 2)

Insulation materialPerformanceTemperature sensorCO2 sensorO2 sensorTemp control range and fluctuation

Temperature uniformity

CO2 control range and fluctuationO2 control rangeHumidity control range and fluctuation

Light control rangeAlarmsPower failureOut of temperature settingHigh temperatureOut of CO2 settingOut of humidity settingDoor openWater levelGeneralExterior materialColour (exterior)Cabinet material (interior)Outside lid/doorReversable doorInside lid/doorLid / outside door lockShelvesMax. load per shelfMax. total loadMax. Shelf capacityAccess port- position- diameterCO2 Incubator Contamination Control & Operating SystemsH2O2 decontamination system (option)SafeCell UV system (option)InCu saFe®

Water level sensorDHA heating systemCO2 incubator optionsShelfs and brackets (InCu saFe®)Half trayRoller baseCO2-gas pressure regulatorAutomatic CO2 switchover systemUV-system kitInner door with 4 small doorsStacking kitDigital interface 1)

Analogue interface 1)

H2O2 decontamination kitH2O2 vapour generator (requires MCO-HL)

Specifications Incubators

mm

mm

ltr

kg

V

Hz

dB

°C

°C

%

%

%RH

Lx

qty

qty

qty

kg

kg

qty

qty

Ø mm

CO2 Incubator Multigas Incubator

PUF = Rigid polyurethane foamed insulation

V = Visual alarmB = Buzzer alarmR = Remote alarm

GROUP

MCO-5AC-PE

480 x 548 x 575

350 x 378 x 375

49

49

230

50

24

PUF

Thermistor

TC

-

Ambient temp

+5 ~ +50, ±0.1

±0.25 4)

0 ~ 20, ±0.15

-

95, ±5

-

-

V-B-R

V-B-R

V-B-R

-

V

V

Painted steel

Bio-gray

SS copper alloyed

1

Y

1

N

3

4

12

6

1

rear

30

N

Y

Y

Y

Y

MCO-30ST

-

MCO-5RB

MCO-100L

MCO-5GC

MCO-19UVS

-

Standard

MTR-480

MCO-420MA

-

-

MCO-18AC-PE

620 x 710 x 900

490 x 523 x 665

170

92

230

50

24

PUF

Thermistor

TC

-

Ambient temp

+5 ~ +50, ±0.1

±0.254)

0 ~ 20, ±0.15

-

95, ±5

-

R

V-B-R

V-B-R

V-B-R

-

V

V

Painted steel

Bio-gray

SS copper alloyed

1

Y

1

N

3

7

28

15

1

rear

30

N

Y

Y

Option

Y

MCO-47ST

MCO-25ST

MCO-18RB

MCO-100L

MCO-21GC

MCO-18UVS3 3)

MCO-19ID

Standard

MTR-480

MCO-420MA

-

-

MCO-19AIC-PE

620 x 710 x 900

490 x 523 x 665

170

93

230

50

30

PUF

Thermistor

Dual IR

-

Ambient temp

+5 ~ +50, ±0.1

±0.254)

0 ~ 20, ±0.15

-

95, ±5

-

-

V-B-R

V-B-R

V-B-R

-

V-B

V

Painted steel

Bio-gray

SS copper alloyed

1

Y

1

N

4

7

28

15

1

rear

30

Y

Y

Y

Y

Y

MCO-47ST

MCO-25ST

MCO-18RB

MCO-100L

MCO-21GC

MCO-19UVS

MCO-19ID

Standard

MTR-480

MCO-420MA

MCO-HL7)

MCO-HP7)

MCO-20AIC-PE

770 x 708 x 900

620 x 523 x 665

215

106

230

50

30

PUF

Thermistor

IR

-

Ambient temp

+5 ~ +50, ±0.1

±0.254)

0 ~ 20, ±0.15

-

95, ±5

-

-

V-B-R

V-B-R

V-B-R

V

V

Painted steel

Bio-gray

SS copper alloyed

1

Y

1

N

5

5

35

15

1

rear

30

N

Standard

Y

Y

Y

MCO-58ST

MCO-35ST

MCO-20RB

MCO-100L

MCO-21GC

Standard

-

Standard 6)

MTR-480

MCO-420MA

-

-

MCO-5M-PE

480 x 548 x 575

350 x 378 x 375

49

50

230

50

24

PUF

Thermistor

TC

Zirconia

Ambient temp

+5 ~ +50, ±0.1

±0.254)

0 ~ 20, ±0.15

1 ~ 18, 22 ~ 80 ±0.2

95, ±5

-

-

V-B-R

V-B-R

V-B-R

-

V

V

Painted steel

Bio-gray

SS copper alloyed

1

Y

1

N

3

4

12

6

1

rear

30

N

Y

Y

Y

Y

MCO-30ST

-

MCO-5RB

MCO-100L

MCO-5GC

MCO-19UVS

-

Standard

MTR-480

MCO-420MA

-

-

MCO-19M-PE

620 x 710 x 900

490 x 523 x 665

170

94

230

50

30

PUF

Thermistor

Dual IR

Zirconia

Ambient temp

+5 ~ +50, ±0.1

±0.254)

0 ~ 20, ±0.15

1 ~ 18, 22 ~ 80 ±0.2

95, ±5

-

R

V-B-R

V-B-R

V-B-R

-

V-B

V

Painted steel

Bio-gray

SS copper alloyed

1

Y

1

N

3

7

28

15

1

rear

30

Y

Y

Y

Y

Y

MCO-47ST

MCO-25ST

MCO-18RB

MCO-100L

MCO-21GC

MCO-19UVS

Standard

Standard

MTR-480

MCO-420MA

MCO-HL7)

MCO-HP7)

l DHA Direct Heat & Air Jacket System for optimal temperature stabilityl Preventative contamination control with InCu saFe®

l 3 minutes CO2 recovery timel Field reversible doors

l Exceptional CO2 and O2 recovery timesl Preventative contamination controll Optional SafeCell UV systeml FDA clearance for IFV use

166

Characteristics

*Appearance and specification are subject to change without notice.

Specifications Incubators

CO2 reach-In Incubator

MCO-80IC-PE

986 x 853 x 2040

806 x 693 x 1524

851

275

230

50

33

PUF

Thermistor

IR

-

Ambient temp. +5 to 50

(AT; 20°C to 35°C)

±0.54)

0 ~ 20, ±0.15

-

Normal mode; >80% R.H.

High mode; > 90% R.H.

-

R

V-B-R

V-B-R

V-B-R

-

V

V

Painted steel

Bio-gray

SS copper alloyed

1 double paned glass

Y

Option

N

5

30

150

5

2

One on each side

40

N

Y

Y

Y

N (laminar airflow)

MCO-80ST

-

-

MCO-100L

MCO-80GC

MCO-80UVS

MCO-80ID (5 small doors)

-

MTR-480

MCO-420MA

-

-

l Exceptional CO2 and O2 recovery timesl Preventative contamination controll Optional SafeCell UV systeml FDA clearance for IFV use

l Laminar Airflowl PID temperature controll InCu saFe®

l High volume of samples

Waterjacket CO2 Incubator

MCO-175-PE

770 x 620 x 900

490 x 505 x 690

170

108

230

50

33

PUF

Pt-100

TC

-

Ambient temp.

+5 ~ +50, ±0.1

±0.2 4)

0 ~ 20, ±0.15

-

95, ±5

-

V-B

V-B

V-B

V-B

-

V

V

Painted steel

Bio-gray

SS SUS-304

1

1

N

6

7

42

19

1

Right hand side

30

N

N

N

N

N (Water Jacket)

MCO-47ST

MCO-25ST

-

-

-

-

-

MCO-175SB

-

-

-

-

l Stable temperature env.l PID temperature controll Power failure protectedl Door heater in outer door

Plant Growth Chamber

MLR-352-PE

760 x 700 x 1835

520 x 490 x 1135

294

226

230

50

45

PUF

Thermistor

0 ~ +50 (Lamp off) ±0.3

+10 ~ +50 (lamp on) ±0.3

±1 (lamp off)

±2.5 (lamp on)

-

-

-

Programmable 0 ~ 20000

R

B-R

B-R

-

-

V-B

-

Painted steel

Bio-beige

SS SUS-304

3

N

1

N

5

25

100

1

Ceiling

40

-

-

-

-

-

-

MTR-480

-

-

-

MLR-352H-PE

760 x 700 x 1835

520 x 490 x 1135

294

235

230

50

45

PUF

Thermistor

+5 ~ +50 (Lamp off) ±0.3

+10 ~ +50 (lamp on) ±0.3

±1 (lamp off)

±2.5 (lamp on)

-

-

60~90 / LS:0 (15~45°C)

55~85 / Lamp On (15~45°C)

Programmable 0 ~ 20000

R

B-R

B-R

-

V

V-B

-

Painted steel

Bio-beige

SS SUS-304

3

N

1

N

5

25

100

1

Ceiling

40

-

-

-

-

-

-

MTR-480

-

-

-

MIR-162-PE

580 x 595 x 820

450 x 460 x 450

93

44

230

50

NA5)

Glass fiber

Thermistor

Ambient temp +5 ~ +80

±0.2 (≤60) ~ ± 0.5 (60 ~ 80)

±1

-

-

-

-

V-B

V-B

-

Painted steel

Bio-gray

SS SUS-304

1

N

1

N

2

15

30

0

-

-

MIR-262-PE

730 x 645 x 870

600 x 510 x 500

153

61

230

50

NA5)

Glass fiber

Thermistor

Ambient temp +5 ~ +80

±0.2 (≤60) ~ ± 0.5 (60 ~ 80)

±1

-

-

-

-

V-B

V-B

-

Painted steel

Bio-gray

SS SUS-304

1

N

1

N

3

15

30

0

-

-

l Programmable temperature, lightning functionl Graphic LCD for easy operationl Microprocessor PID & refrigeration capacity controll Data logging Function

Heated Incubators

l Microcomputer PID controll Microcomputer timer functionl Advanced designed control panell Air Jacketed heating system

167

Specifications Inventory Racks

*Appearance and specification are subject to change without notice.

168

Chest freezer model Vertical rack type Box type Rack/quantity Wesbart (aluminium) Total boxes Storage Cases/quantity Rack/quantity Tenak (stainless steel) Total boxes

MDF-C2156VAN-PE side openings (P) A1 15 x NIR-210C 150 9 x MDF-49SC 15 x TE-NIR-211COM 165 side openings (P) A2 15 x NIR-307C 105 15 x TE-NIR-307COM 105MDF-1156-PE side openings (P) A1 9 x NIR-209C 81 6 x MDF-49SC 9 x TE-NIR-210COM 90 side openings (P) A2 9 x NIR-306C 54 9 x TE-NIR-307COM 63MDF-C8V1-PE side openings (P) A1 6 x NIR-207C 42 4 x MDF-19SC 6 x TE-NIR-207COM 42 side openings (P) A2 6 x NIR-305C 30 6 x TE-NIR-305COM 30MDF-794-PE side openings (P) A1 36 x NIR-213C 468 24 x MDF-59SC 39 x TE-NIR-213COM 507 side openings (P) A2 36 x NIR-309C 324 39 x TE-NIR-309COM 351MDF-594-PE side openings (P) A1 24 x NIR-213C 312 18 x MDF-59SC 27 x TE-NIR-213COM 351 side openings (P) A2 24 x NIR-309C 216 27 x TE-NIR-309COM 243MDF-394-PE side openings (P) A1 21 x NIR-209C 189 MDF-39SC 21 x TE-NIR-209COM 189 side openings (P) A2 21 x NIR-306C 126 21 x TE-NIR-306COM 126MDF-193-PE side openings (P) A1 6 x NIR-207C 42 6 x MDF-19SC 9 x TE-NIR-207COM 63 side openings (P) A2 6 x NIR-305C 30 9 x TE-NIR-305COM 45

Upright freezer model Vertical rack type Box type Rack/quantity Wesbart (aluminium) Total boxes Storage Cases/quantity Rack/quantity Tenak (stainless steel) Total boxes

MDF-U4186S-PE with trays (P) A1 8 x HCS-460 + 8 x HCS-558 216 8 x MDF-48SC 8 x TE-HCS-243COM + 8 x TE-HCS-253COM 216 side opening (P) A1 8 x NIR-212U + 8x NIR-215U 216 8 x TE-NIR-243CLA + 8 x TE-NIR-253CLA 216 with trays (P) A2 16 x HCS-380 144 16 x TE-HCS-333COM 144 side opening (P) A2 16 x NIR-309U 144 16 x TE-NIR-333CLA 144MDF-U3386S-PE with trays (P) A1 6 x HCS-32-4584/143 + 6 x HCS-32-5584/143 216 - 6 x TE-HCS-244COM + 6 x TE-HCS-254COM 216 side opening (P) A1 6 x NIR-216U + 6 x NIR-220U 216 6 x TE-NIR-244CLA + 6 x TE-NIR-254CLA 216 with trays (P) A2 12 x HCS-32-3804/143 144 12 x TE-HCS-334COM 144 side opening (P) A2 12 x NIR-312U 144 12 x TE-NIR-334CLA 144MDF-U33V-PE with trays (P) A1 6 x HCS-32-4584/143 + 6 x HCS-32-5584/143 216 - 6 x TE-HCS-244COM + 6 x TE-HCS-254COM 216 side opening (P) A1 6 x NIR-216U + 6 x NIR-220U 216 6 x TE-NIR-244CLA + 6 x TE-NIR-254CLA 216 with trays (P) A2 12 x HCS-32-3804/143 144 12 x TE-HCS-334COM 144 side opening (P) A2 12 x NIR-312U 144 12 x TE-NIR-334CLA 144MDF-U5386S-PE with trays (P) A1 16 x HCS-5584 320 - 16 x TE-HCS-254COM 320 side opening (P) A1 16 x NIR-220U 320 16 x TE-NIR-254CLA 320 with trays (P) A2 16 x HCS-3804 192 16 x TE-HCS-334COM 192 side opening (P) A2 16 x NIR-312U 192 16 x TE-NIR-334CLA 192MDF-U55V-PE/ with trays (P) A1 4 x HCS-519 352MDF-U500VX-PE with trays (P) A1 8 x HCS-5584 + 8 x HCS-6564 352 32 x MDF-70SC 8 x TE-HCS-254COM + 8 x TE-HCS-264COM 352 side opening (P) A1 8 x NIR-220U + 8 x NIR-224U 352 8 x TE-NIR-254CLA + 8 x TE-NIR-264CLA 352 with trays (P) A2 8 x HCS-4804 + 8 x HCS-3804 224 8 x TE-HCS-334COM + 8 x TE-HCS-344COM 224 side opening (P) A2 8 x NIR-316U + 8 x NIR-312U 224 8 x TE-NIR-334CLA + 8 x TE-NIR-344CLA 224MDF-U7386S-PE with trays (P) A1 24 x HCS-5574 480 24 x TE-HCS-254COM 480 side opening (P) A1 24 x NIR-220U 480 - 24 x TE-NIR-254CLA 480 with trays (P) A2 12 x HCS-3804 + 12 x HCS-4804 336 24 x TE-HCS-334COM 288 side opening (P) A2 24 x NIR-312U 336 24 x TE-NIR-334CLA 288MDF-U74V-PE/ with trays (P) A1 6 x HCS-519 528MDF-U700VX-PE with trays (P) A1 12 x HCS-5584 + 12 x HCS-6564 528 48 x MDF-70SC 12 x TE-HCS-254COM + 12 x TE-HCS-264COM 528 side opening (P) A1 12 x NIR-220U + 12 x NIR-224U 528 12 x TE-NIR-254CLA + 12 x TE-NIR-264CLA 528 with trays (P) A2 12 x HCS-4804 + 12 x HCS-3804 336 24 x TE-HCS-344COM 384 side opening (P) A2 12 x NIR-316U + 12 x NIR-312U 336 24 x TE-NIR-344CLA 384

All boxes are available:in Polypropylene (P) or carton (A) as 2 inch (1) or 3 inch (2)

HDR-216HCS-6564HCS-5584HCS-519NIR-312UNIR-224UNIR-213CNIR-210C HDR-222

Notes1) Nominal Value2) MIR-L15 operates between +2°C and +50°C

MODELDimensionsExternal dimensions (W x D x H)Internal dimensions (W x D x H)VolumeNet weightTechnical DataPower supplyFrequencyNoise level 1)

RefrigerationInsulation materialInsulation thicknessCompressorRefrigerantCooling methodPerformanceTemperature sensorTemp control range and fluctuation

Temperature uniformityPerformance ambient temperatureAlarmsPower failureHigh temperatureLow temperatureFilterLid/door openGeneralExterior materialColour (exterior)Cabinet materialOutside lid/doorReversable doorInside lid/door

Lid / outside door lockShelvesMax. load per shelfMax. total loadAccess port- position- diameterInteriour fluorecent lampOptionsComunications interface

Specifications Inventory Racks

mm

mm

ltr

kg

V

Hz

dB

mm

W

°C

°C

°C

qty

kg

kg

qty

Ø mm

qty, W

Programmable Cooled Incubators

PUF = Rigid polyurethane foamed insulation

V = Visual alarmB = Buzzer alarmR = Remote alarm

GROUP

MIR-154-PE

700 x 580 x 1018

620 x 368 x 555

123

78

230

50

41

40

150

R-134a

-

Y

N

MIR-LP option

3

20

61

1

left side

40

MIR-554-PE

800 x 832 x 1810

640 x 550 x 1160

406

195

230

50

45

80

250

R-404A

R

N

2 small inner doors

(MIR-55ID option)

MIR-LP option

Y

5

50

250

2

left and right side

40

l High-precision temperature environmentl Microprocessr controled for optimal sample securityl Refined alarm and security systemsl Programmable operation for long lasting experimentation

PUF

Forced air circulation

Thermistor

-10 ~ +60 (AT; +5 ~ +35, no load), ±0.2 with Heater PID control (SV 50),

±1.5 with Compressor control (SV 5)

±0.5 SV (35)

20, no load

-

V-B-R

V-B-R

-

V-B

Painted steel

Bio-gray

SS SUS-304

1

40

1, 15, with MIR-L152 option

MTR-480, MTR-L03

*Appearance and specification are subject to change without notice.

169

MIR-254-PE

700 x 580 x 1618

620 x 368 x 1088

238

108

230

50

44

40

250

R-404a

Y

N

MIR-LP option

5

20

100

1

left side

Characteristics

Chest freezer model Vertical rack type Box type Rack/quantity Wesbart (aluminium) Total boxes Storage Cases/quantity Rack/quantity Tenak (stainless steel) Total boxes

MDF-C2156VAN-PE side openings (P) A1 15 x NIR-210C 150 9 x MDF-49SC 15 x TE-NIR-211COM 165 side openings (P) A2 15 x NIR-307C 105 15 x TE-NIR-307COM 105MDF-1156-PE side openings (P) A1 9 x NIR-209C 81 6 x MDF-49SC 9 x TE-NIR-210COM 90 side openings (P) A2 9 x NIR-306C 54 9 x TE-NIR-307COM 63MDF-C8V1-PE side openings (P) A1 6 x NIR-207C 42 4 x MDF-19SC 6 x TE-NIR-207COM 42 side openings (P) A2 6 x NIR-305C 30 6 x TE-NIR-305COM 30MDF-794-PE side openings (P) A1 36 x NIR-213C 468 24 x MDF-59SC 39 x TE-NIR-213COM 507 side openings (P) A2 36 x NIR-309C 324 39 x TE-NIR-309COM 351MDF-594-PE side openings (P) A1 24 x NIR-213C 312 18 x MDF-59SC 27 x TE-NIR-213COM 351 side openings (P) A2 24 x NIR-309C 216 27 x TE-NIR-309COM 243MDF-394-PE side openings (P) A1 21 x NIR-209C 189 MDF-39SC 21 x TE-NIR-209COM 189 side openings (P) A2 21 x NIR-306C 126 21 x TE-NIR-306COM 126MDF-193-PE side openings (P) A1 6 x NIR-207C 42 6 x MDF-19SC 9 x TE-NIR-207COM 63 side openings (P) A2 6 x NIR-305C 30 9 x TE-NIR-305COM 45

Upright freezer model Vertical rack type Box type Rack/quantity Wesbart (aluminium) Total boxes Storage Cases/quantity Rack/quantity Tenak (stainless steel) Total boxes

MDF-U4186S-PE with trays (P) A1 8 x HCS-460 + 8 x HCS-558 216 8 x MDF-48SC 8 x TE-HCS-243COM + 8 x TE-HCS-253COM 216 side opening (P) A1 8 x NIR-212U + 8x NIR-215U 216 8 x TE-NIR-243CLA + 8 x TE-NIR-253CLA 216 with trays (P) A2 16 x HCS-380 144 16 x TE-HCS-333COM 144 side opening (P) A2 16 x NIR-309U 144 16 x TE-NIR-333CLA 144MDF-U3386S-PE with trays (P) A1 6 x HCS-32-4584/143 + 6 x HCS-32-5584/143 216 - 6 x TE-HCS-244COM + 6 x TE-HCS-254COM 216 side opening (P) A1 6 x NIR-216U + 6 x NIR-220U 216 6 x TE-NIR-244CLA + 6 x TE-NIR-254CLA 216 with trays (P) A2 12 x HCS-32-3804/143 144 12 x TE-HCS-334COM 144 side opening (P) A2 12 x NIR-312U 144 12 x TE-NIR-334CLA 144MDF-U33V-PE with trays (P) A1 6 x HCS-32-4584/143 + 6 x HCS-32-5584/143 216 - 6 x TE-HCS-244COM + 6 x TE-HCS-254COM 216 side opening (P) A1 6 x NIR-216U + 6 x NIR-220U 216 6 x TE-NIR-244CLA + 6 x TE-NIR-254CLA 216 with trays (P) A2 12 x HCS-32-3804/143 144 12 x TE-HCS-334COM 144 side opening (P) A2 12 x NIR-312U 144 12 x TE-NIR-334CLA 144MDF-U5386S-PE with trays (P) A1 16 x HCS-5584 320 - 16 x TE-HCS-254COM 320 side opening (P) A1 16 x NIR-220U 320 16 x TE-NIR-254CLA 320 with trays (P) A2 16 x HCS-3804 192 16 x TE-HCS-334COM 192 side opening (P) A2 16 x NIR-312U 192 16 x TE-NIR-334CLA 192MDF-U55V-PE/ with trays (P) A1 4 x HCS-519 352MDF-U500VX-PE with trays (P) A1 8 x HCS-5584 + 8 x HCS-6564 352 32 x MDF-70SC 8 x TE-HCS-254COM + 8 x TE-HCS-264COM 352 side opening (P) A1 8 x NIR-220U + 8 x NIR-224U 352 8 x TE-NIR-254CLA + 8 x TE-NIR-264CLA 352 with trays (P) A2 8 x HCS-4804 + 8 x HCS-3804 224 8 x TE-HCS-334COM + 8 x TE-HCS-344COM 224 side opening (P) A2 8 x NIR-316U + 8 x NIR-312U 224 8 x TE-NIR-334CLA + 8 x TE-NIR-344CLA 224MDF-U7386S-PE with trays (P) A1 24 x HCS-5574 480 24 x TE-HCS-254COM 480 side opening (P) A1 24 x NIR-220U 480 - 24 x TE-NIR-254CLA 480 with trays (P) A2 12 x HCS-3804 + 12 x HCS-4804 336 24 x TE-HCS-334COM 288 side opening (P) A2 24 x NIR-312U 336 24 x TE-NIR-334CLA 288MDF-U74V-PE/ with trays (P) A1 6 x HCS-519 528MDF-U700VX-PE with trays (P) A1 12 x HCS-5584 + 12 x HCS-6564 528 48 x MDF-70SC 12 x TE-HCS-254COM + 12 x TE-HCS-264COM 528 side opening (P) A1 12 x NIR-220U + 12 x NIR-224U 528 12 x TE-NIR-254CLA + 12 x TE-NIR-264CLA 528 with trays (P) A2 12 x HCS-4804 + 12 x HCS-3804 336 24 x TE-HCS-344COM 384 side opening (P) A2 12 x NIR-316U + 12 x NIR-312U 336 24 x TE-NIR-344CLA 384

Specifications Incubators

*Appearance and specification are subject to change without notice.

MODELDimensionsExterior (W x D x H)Interior (W x D x H)Effective capacityNet weightConstructionExterior finish

Interior finishInsulationSee through window

ShelvesMax load per shelfTemperature, Light & HumidityAir exhaust ventInterior fanExterior fanHeating systemTemperature setting

Temperature/timer displayTemperature rangeTemperature controlTemperature uniformitySensorAlarms & Safety functions

MODELDimensionsExterior (W x D x H)Chamber dimensions (diameter x depth)Effective chamber height incl. recess in lidEffective capacityNet WeightConstructionChamber materialInterior finishStainless steel basketsSterilizationMax. pressureSterilisation temperatureTemperature gauge rangeCulture media melting temperatureSafety valve release pressurePressure gauge rangeTimer setting rangeKeep warm temperatureSterilisation timerMelting timerKeep warm timerExhaust tankExhaust control

Safety Devices

Pressure vessel

Specifications Autoclaves & Laboratory Ovens

mm

mm

ltr

kg

qty

kg

°C

°C

°C

mm

Ø mm

mm

ltr

kg

Mpa

°C

°C

°C

min.

°C

min

min

hrs

Laboratory Ovens Dry Heat SterilizersGROUP

MOV-112S-PE

580 x 595 x 820

450 x 450 x 450

90

50

Baked acrylic finish on

galavanized steel

Stainless-steel plate (SUS-304)

Glass wool

Reinforced triple glass window

(t=5 mm)

2

15

Two on top plate (32mm inside Ø)

Sirocco fan, Ø 149 mm

Propeller fan, Ø 107 mm

Forced air circulation system

Digital setting

(adjustable range +/- 1°C)

Digital LED display

40 ~ 200

+/- 1 deg

+/- 4 (AT 200°C)

Thermo couple

MLS-3751L-PE

478 x 632 x 748

370 x 415

463

50

61

Stainless steel (SUS 304)

Stainless steel plate

1 large & 1 small

0,240

115 ~ 135

-

60 ~ 114

-

-

-

45 ~ 60

1 to 300

1 to 300

72 hours fixed

2 ltr polyethylene tank

Exhaust valve open temperature

setting

Pressure safety valve

Over-temperature limiter

Over-pressure limiter

Anti-scorch limiter

Door interlock

Current fuse

Small-scale pressure vessel

MLS-3781L-PE

478 x 632 x 965

370 x 630

688

75

71

Stainless steel (SUS 304)

Stainless steel plate

2 large & 1 small

0,240

115 ~ 135

-

60 ~ 114

-

-

-

45 ~ 60

1 to 300

1 to 300

72 hours fixed

2 ltr polyethylene tank

Exhaust valve open temperature

setting

Pressure safety valve

Over-temperature limiter

Over-pressure limiter

Anti-scorch limiter

Door interlock

Current fuse

Small-scale pressure vessel

MLS-2420U-PE

380 x 490 x 840

240 x 450

20

45

Stainless steel (SUS 304)

-

2

-

105 ~ 126

Digital display 80 ~ 141

-

177 kPa (25 psig)

0 - 0.3 Mpa / 0 -45 psi

1 - 180

-

-

-

-

3 ltr polyethylene tank

-

Pressure safety valve

Anti dry scorch thermo limiter

Door switch

Handle switch

Current fuse

-

MLS-3020U-PE

440 x 550 x 1050

300 x 670

48

67

Stainless steel (SUS 304)

-

3

-

105 ~ 126

Digital display 80 ~ 141

-

177 kPa (25 psig)

0 - 0.3 Mpa / 0 -45 psi

1 - 180

-

-

-

-

3 ltr polyethylene tank

-

Pressure safety valve

Anti dry scorch thermo limiter

Door switch

Handle switch

Current fuse

-

MOV-212S-PE

730 x 645 x 870

600 x 500 x 500

150

66

Baked acrylic finish on

galavanized steel

Stainless-steel plate (SUS-304)

Glass wool

Reinforced triple glass window

(t=5 mm)

3

15

Two on top plate (32mm inside Ø)

Sirocco fan, Ø 149 mm

Propeller fan, Ø 107 mm

Forced air circulation system

Digital setting

(adjustable range +/- 1°C)

Digital LED display

40 ~ 200

-

+/- 4 (AT 200°C)

Thermo couple

MOV-112F-PE

580 x 595 x 820

450 x 450 x 450

90

50

Baked acrylic finish on

galavanized steel

Stainless-steel plate (SUS-304)

Glass wool

Reinforced triple glass window

(t=5 mm)

2

15

Two on top plate (32mm inside Ø)

Sirocco fan, Ø 149 mm

Propeller fan, Ø 107 mm

Forced air circulation system

Digital setting

(adjustable range +/- 1°C)

Digital LED display

40 ~ 200

+/- 1 deg

+/- 4 (AT 200°C)

Thermo couple

MOV-212F-PE

730 x 645 x 870

600 x 500 x 500

150

66

Baked acrylic finish on

galavanized steel

Stainless-steel plate (SUS-304)

Glass wool

Reinforced triple glass window

(t=5 mm)

3

15

Two on top plate (32mm inside Ø)

Sirocco fan, Ø 149 mm

Propeller fan, Ø 107 mm

Forced air circulation system

Digital setting

(adjustable range +/- 1°C)

Digital LED display

40 ~ 200

+/- 1 deg

+/- 4 (AT 200°C)

Thermo couple

automatic set temperature (set point 10°C), independent overheating protection circuit,

overtemperature safety system for control section, self diagnosis

Autoclaves Laboratory AutoclavesGROUP

170

l Microprocessor PID temperature control system l Self diagnosis function l Various alarm and safety devicesl Accurate high temperature oven

l Designed for individual lab usel Surprisingly large chamber

l 4 Selectable coursesl 3 Customizable programs

l Accurate sterilisation temperaturel Fail-safe functions

l Audible and visual alarmsl Compact design

Characteristics

Characteristics

*Appearance and specification are subject to change without notice.

Specifications Autoclaves & Laboratory Ovens

Laboratory Ovens

MOV-112-PE

580 x 595 x 820

450 x 450 x 450

97

47

Baked acrylic finish on

galavanized steel

Stainless-steel plate (SUS-304)

Glass wool

Reinforced triple glass window

(t=5 mm)

2

15

Two on top plate (32mm inside Ø)

-

-

Natural convection system

Digital setting

(adjustable range +/- 1°C)

Digital LED display

40 ~ 250

+/- 1 deg

+/- 10 (AT 200°C)

Thermo couple

MOV-212-PE

730 x 645 x 870

600 x 500 x 500

157

63

Baked acrylic finish on

galavanized steel

Stainless-steel plate (SUS-304)

Glass wool

Reinforced triple glass window

(t=5 mm)

3

15

-

Two on top plate (32mm inside Ø)

-

-

Natural convection system

Digital setting

(adjustable range +/- 1°C)

Digital LED display

40 ~ 250

+/- 1 deg

+/- 10 (AT 200°C)

Thermo couple

171

l Microprocessor PID temperature control system l Self diagnosis function l Various alarm and safety devicesl Accurate high temperature oven

l Accurate sterilisation temperaturel Fail-safe functions

l Audible and visual alarmsl Compact design

MODELDimensionsExternal dimensions (WxDxH)

Internal dimensions (WxDxH)net weightTechnical DataPower supplyFrequencyNoise level 1)

Shaking motionAmplitude of orbiting motionRevolutionOperating temperature range

Operating CO2 rangeOperating relative humidity rangeMotorFlask capacitySoft startTimerMaximum loadAlarmsPower failureRevolution abnormalityMotor overloadAbnormal vibrationTemperature abnormalityGeneralExterior material

Colour (exterior)OptionsInCu saFe® PlatformFlask clampsTest tube rackCommunications interface

mm

mm

kg

V

Hz

dB

mm

rpm

°C

%

%

kg

Orbital Shaker

PUF = Rigid polyurethane foamed insulation

V = Visual alarmB = Buzzer alarmR = Remote alarm

GROUP

MIR-S100-PE MIR-S100C-PE

l Compact design & intelligent operationl Low-vibration & low-noisel Preventative contamination control with InCu saFe® platforml Easy installation in Panasonic incubators or growth chambers

410 x 305 x 120 Shaker 409 x 275 x 118

Controller 365 x 275 x 93

Platform 380 x 250

15 Shaker - 12, controller - 4

230

50

38 2) 38.9

Circular orbit

20

50 ~ 500 40 ~ 200

0 ~ 60 Shaker 0 ~ 50 in CO2;

Controller 0 ~ 40

Ambient 0 ~20

≤80 Shaker ≤95, controller ≤80

Brushless DC

e.g. 11 x 100ml, 6 x 500ml

Y

0-99.9 hrs

5

-

V-B-R

V-B-R

V-B-R

V-B-R

Body painted steel, Controller painted steel,

platform SS copper alloyed shaker SS copper alloyed

Bio-gray Bio-gray, SS

MIR-38PFN

Available for 50, 100, 200, 500, 1000, 2000 ml

MIR-204SC

MTR-480, MTR-L03

Orbital Shaker for CO2 Incubators

Characteristics

*Appearance and specification are subject to change without notice.

Notes1) Nominal Value2) Nominal value in a 13dB background, no load

Specifications Orbital Shakers

Panasonic Biomedical Sales Europe B. V.

Nijverheidsweg 120

4879 AZ Etten Leur

The Netherlands

Tel: +31 (0)76 543 38 33

Fax: +31 (0)76 541 37 32

[email protected]

www.panasonic.eu/biomedical

Panasonic Healthcare Co., Ltd., Gunma factory is certified for:

Quality management system: ISO9001 / Medical devices quality management system: ISO13458 / Environmental management system: ISO14001

©2012 Panasonic Biomedical Sales Europe B.V.Publication Number: 22764