Post on 22-Nov-2015
DVOR ASII
DVOR ASII
I. KALIBRASI.
ITEM YANG DICHECK PADA RUTIN KALIBRASI ADALAH:
1. MODULASI 30 HZ AM (REFF). HARUS 30 %
2. MODULASI 9960 HZ (30 HZ VAR). HARUS 30 %
3. MODULASI IDENT. BIASANYA 5 %
4. AZ. INDEX . KALAU MENGGUNAKAN ANTENNA UTARA BERARTI AZ.INDEX HARUS 0 DERAJAT, DAN BILA MENGGUNAKAN ANTENNA FIELD SELATAN HARUS 180 DERAJAT.
TINDAKAN YANG DILAKUKAN.
MASUK PADA MENU G;1 UNTUK TX-1 DAN MENU G;2 UNTUK TX-2
SAAT KALIBRASI YANG PERLU DIPERHATIKAN SBB:
a. TX HARUS POSISI BY PASS. INI UNUTK MENCEGAH TX CHANGE OVER BILA DATA YANG TERBACA DILUAR TOLERANSI YANG TELAH DISETTING.
b. SETELAH SELESAI KALIBRASI SESUAIKAN LAGI NILAI-NILAI TOLERANSI DARI DATA. (PADA MENU G. LOW & HIGH LIMIT)
c. JANGAN LUPA UNTUK DI SAVE G;1,13. BILA TIDAK MAKA DATA YANG TELAH DIRUBAH AKAN HILANG LAGI KETIKA MATI LISTRIK.
CONTOH : UNTUK TX-1
a. 30 HZ REFF. MOD.
SEBELUM KALIBRASI, TERBACA PADA MENU G;1,7 = 28.50 %
PADA PESAWAT KALIBRASI TERBACA= 29 %
BERARTI 30 HZ REFF MOD HARUS DINAIKAN 1 % AGAR TERBACA DI A/C 30 %.
KETIK G;1,7,2950 ENTER. (28.50 % + 1 %. 29.50 % GROUND = 30 % MONITOR A/C)
b. 9960 HZ / 30 HZ VAR
SEBELUM KALIBRASI TERBACA PADA MENU G;1,8 = 23.00
PADA A/C KALIBRASI TERBACA= 29.00 %
BERART 30 HZ VAR MOD HARUS DINAIKAN 1 % AGAR TERBACA DI A/C 30 %
KETIK G;1,8,2400 ENTER. (23.00 + 1 = 24.00 % )
PERUBAHAN MOD BUTUH WAKTU 1-2 MENIT KARENA PROSES MODULASI TERJADI DI UDARA.
APABILA DENGAN MENU G;1,8 TIDAK TERKEJAR, RUBAH POWER (G;1,2) DENGAN KAIDAH YANG BERLAKU PADA TABEL DI ATAS.
c. IDENT
SEBELUM KALIBRASI TERBACA PADA MENU G;1,6 = 5.00 %
PADA A/C KALIBRASI TERBACA = 3 %
KETIK G;1,6,700 ENTER. (5 % + 2 % = 7 % )
d. AZ INDEX
SEBELUM KALIBRASI TERBACA PADA MENU G;1,1 = -0.3 DEG
PADA A/C KALIBRASI TERBACA ERROR= 2 DEG
BERARTI AZ INDEX HARUS DI GESER KE 2 DEG AGAR MENJADI 0 DEG. KALAU KITA MENGGUNAKAN FIELD DETECTOR UTARA.
KETIK G;1,1,-2.30 ENTER. (-0.3 + (-2) = -2.3).
II. SPESIFIKASI DVOR-KUPANG
I/P POWER SUPPLY: 115/230 VAC (SINGLE PHASE) ATAU 48 VDC
POWER CONSUMTION 2 TX: 3000 WATT MAX.
CARRIER FREQ: 112.200.000 HZ +/- 0.002 %
111.975.600 HZ S/D 112.424.400 HZ
CARRIER O/P: 100 WATT
MAXIMUM RANGE: 175 NM (LINE OF SIGHT)
REFF MODULASI: 30 HZ +/- 0.01 % (AM). 29.7 HZ S/D 30.3 HZ
MODULASI DEPTH 28 % - 32 % (DIGITAL
CONTROL)
VAR MODULATION: 30 HZ +/- 0.001 % (FM)
SUB CARRIER SIGNAL: 9960 HZ +/- 1%
DEVIASI 16 +/- 1 PADA 115 MHZ
MOD DEPTH 28% -32% (DIGITAL CONTROL)
IDENT: 1020 HZ +/- 10 HZ
MOD DEPTH 5 20 %
ANTENNA SYSTEM: TYPE ANTENNA: ALFORD LOOP
FREQ.RQNGE: 108 118 MHZ
POLARIZATION: HORISONTAL
JUML ANTENNA: 48 SB, 1 CARR
MOD TYPE: DOUBLE SIDE BAND
FIELD MONITOR: TYPE ANT.: YAGI
FREQ. RANGE: 108 118 MHZ
O/P: COMPOSITE SIGNAL, RF
INSTALATION: 900 FEET DARI CENTRE
COUNTERPOISE SELEVEL DNG COUNTERPOISE.
MONITOR: CONFIGURASI: AND OR
III. FILOSOFI DVOR ASII - KUPANG
1. FREQ. 112.200 000 HZ (CARR FREQ)
2. CARR FREQ. DITUMPANGI SECARA AM DENGAN :
30 HZ REFF ( 30 %)
IDENT (5 %)
3. FREQ CARR TERMODULASI INI DIPANCARKAN SECARA CONTINOUS LEWAT ANTENNA REFF. (ANTENNA TENGAH DVOR).
4. FREQ. LAIN YANG DIPANCARKAN
112,190 000 (LSB)
112 210 000 (USB)
5. FREQ. SB INI DIPANCARKAN SECARA BERGANTIAN MELALUI KE-48 ANTENNA SB DENGAN ARAH PUTARAN PANCARAN CCW.
6. SECARA BERSAMAAN ADA 5 BUAH ANTENNA YANG BEKERJA YANG MEMANCARKAN SIGNAL BERUPA:
FREQ. CARR 112.2 MHZ
FREQ. LSB SIN 112.190 000 HZ
FREQ. LSB COS 112.190 000 HZ
FREQ. USB SIN 112 200 000 HZ
FREQ. USB COS 112 000 000 HZ
7. FREQ SB DIPANCARKAN SECARA BERGANTIAN DENGAN KECEPATAN PUTARAN 1800 RPM (PUTARAN / MNT) = 1800/60 DETIK = 30 PUTARAN/DETIK = 30 HZ. KARENA FREQ YANG DIPANCARKAN BERGERAK/BERPUTAR MAKA TIMBUL EFEK DOPPLER YANG MENYEBABKAN TERMODULASINYA SECARA FM 30 HZ (HASIL KECEPATAN PUTARAN) TERHADAP CARRIER. BESARNYA MODULASI 30 HZ VAR INI DAPAT DIATUR DENGAN MERUBAH POWER SB 1-4 (PADA MENU G;1,8) ATAU DENGAN MERUBAH LEVEL/POWER PANCAR CARR. G;1,2.
8. SB SIN DAN SB COS DIPANCARKAN BERSAMAAN DENGAN TUJUAN AGAN LEVEL SB YANG DITERIMA A/C SETIAP SAAT SELALU CONSTAN.
9. ANT SB:
ANT GANJI KECIL 1-23 MEMANCARKAN LSB SIN
ANT GENAB KECIL 2-24 MEMANCARKAN LSB COS
ANT GANJIL BESAR 25-47 MEMANCARKAN USB SIN
ANT GENAB BESAR MEMANCARKAN USB COS.
DENGAN KATA LAIN
ANTENNA GANJIL MEMANCARKAN SIN DAN ANTENNA GENAB MEMANCARKAN COS.
ANTENNA KECIL 1-25 MEMANCAR LSB DAN ANTENNA BESAR MEMANCARKAN USB.
SWICHING ANTENNA DIATUR DALAM COMUTATOR.
IV. MODUL DAN CARD DVOR ASII
1. STATUS DISPLAY PANEL MODUL
PANEL DISPLAY TERDIRI DARI LAMPU LED YANG MENUNJUKAN KONDISI KERJA DVOR.
LED HIJAU NYALA: DVOR TX NORMAL
LED HIJAU BERKEDIP: DVOR TX POSISI STAND BY
LED KUNING NYALA: DVOR TX POSISI BY PASS
LED MERAH NYALA: ADA MODUL / CARD DVOR YANG ALARM.
2. RF MONITOR MODUL
TERLETAK DISEBELAH DALAM MODUL PANEL DISPLAY.
FUNGSI MEMONITOR RF SIGNAL O/P YANG TELAH DIFILTER BERUPA FREQ CARR DAN SB.
3. CARRIER PLUS SIDE BAND (CSB) POWER AMP MODUL
FUNGSI MEMODULASI FREQ CARR DENGAN FREQ 30 HZ REFF + IDENT DAN MENGAMP.
MODUL INI TERDIRI DARI CARD :
POWER AMPLIFIER MODULATOR.
BIAS REGULATOR / EXCITER MOD.
EXCITER
PA
4. RF GENERATOR MODUL
TERDAPAT 3 BUAH KRISTAL YANG MASING-MASING MENGHASILKAN FREQ CARR, LSB DAN USB. SETIAP DAERAH MEMPUNYAI RF. GEN YANG BERBEDA.
FUNGSINYA SEBAGAI GENERATOR 3 FREQ TINGGI DAN JUGA SEBAGAI PA CARRIER YANG AKAN DIPANCARKAN LEWAT ANTENNA CARR.
MODUL INI TERDIRI DARI :
CARRIER/SB DRIVE
FREQ. GEN CONTROL
MIXER
DUA VOLTAGE CONTROL CRISTAL OSC.
5. SB AMP / SB. GEN MODUL
ADA DUA BUAH MODUL. MASING-MASING MODUL TERDIRI DARI 2 AMP YANG TERPISAH.
MODUL SEBELAH KIRI UNTUK SB 1 DAN 2 . MODUL KANAN UNTUK SB 3 DAN 4. DENGAN RINCIAN SBB:
SB 1 = LSB SIN
SB 2 = LSB COS
SB 3 = USB SIN
SB 4 = USB COS
FUNGSI MODUL INI UNTUK MENGAMPLIFIER FREQ SB YANG AKAN DIPANCARKAN LEWAT COMUTATOR. POWER SB KECIL(KURANG DARI 5 WATT. SEKITAR 1,5 2 WATT)
TIAP MODUL SIDE BAND TERDIRI DARI:
DUA SB AMP CARD.
DUA SB CONTROL CARD
6. AUDIO GENERATOR CARD.
FUNGSI: MENGHASILKAN FREQ RENDAH. DIANTARANYA:
30 HZ AM (30 HZ REFF)
FREQ. IDENT 1020 HZ
360 HZ SIN (KEPERLUAN SWITCHING FREQ SB)
360 HZ SIN (KEPERLUAN SWITCHING FREQ SB)
LEVEL DC (UNTUK PENGATURAN % MOD 30 HZ REFF DAN POWER)
7. MONITOR CARD
FUNGSI : MEMONITOR HASIL PANCARAN DARI DVOR ASII DENGAN CARA MEMBANDINGKAN SIGNAL PANCAR DENGAN SIGNAL SUMBER/GEN.
RF MONITOR TIAP TX DIPAKAI BERSAMA-SAMA. BILA SALAH SATU MONITOR MENYATAKAN HASIL PANCAR JELEK TETAPI MONITOR YANG LAIN MENYATAKAN BAIK, MAKA HASIL PANCARAN DIANGGAP BAIK. BILA KE-2 MONITOR MENYATAKAN HASIL PANCAR JELEK MAKA DVOR AKAN CHANGE OVER KE TX STAND BY.
BILA DATA FIELD INTENSITY DILUAR TOLERANSI MAKA DATA YANG DIBERIKAN DIANGGAP OUT OFF TOLERANSI SEHINGGA TX CHANGE OVER.
BILA DILAKUKAN TINDAKAN BY PASS, BERARTI MONITOR DAN FIELD DETECTOR TIDAK DIGUNAKAN. SEHINGGA APAPUN YANG TERJADI PADA DVOR, TX TIDAK BISA CHANGE OVER. PADA PANEL DVOR AKAN NYALA LAMPU KUNING, SEDANGKAN PADA PANEL REMOT CONTROL LED HIJAU HANYA NYALA 1 BH.
8. MODEM CARD (1A9)
SEBAGAI INTERFACE PENGHUBUNG ANTARA DVOR DENGAN OFFSITE COMPUTER TERMINAL (RMM)
9. SERIAL INTERFACE (1A10)
SEBAGAI INTERFACE COMM ANTARA CPU DENGAN PERALATAN LAIN. MEMPUNYAI EMPAT DUAL CHANNEL COMM YANG MENGHUBUNGKAN CPU DENGAN :
VIDEO TERMINAL
DME TRANSPONDER 1 & 2
AUDIO GENERATOR UNTUK TX 1 & 2
DVOR MONITOR 1 & 2
10. FACILITIES CARD (1A11)
FUNGSI : PENGUMPUL/PENAMPUNG SELURUH STATUS INFORMASI DVOR SISTEM DAN MENGIRIMKANNYA KE CPU UNTUK DI PROSES ATAU DI SIMPAN.
TERHUBUNG DENGAN: RSCU SEBAGAI CONTROL SIGNAL , CONTROL SIGNALON/OFF BCPS, SEBAGAI LED DRIVER PADA DISPLAY PANEL
11. TEST GENERATOR (1A12)
FUNGSI: 1. MEMBERIKAN STANDAR SIGNAL REFF KEPADA MONITOR DVOR UNTUK AUTOMATIC CALIBRASI KETIKA DVOR DI ON.
2. UNTUK KEPERLUAN MAINTENANCE. MISALNYA TEKNISI MENCOBA MERUBAH PARAMETER PANCAR DARI DVOR. APAKAH AKAN TERJADI ALARM/TIDAK.
12. CPU (1A13)
FUNGSI: UNTUK MENGONTROL DAN MEMONITOR SYSTEM DVOR. BERKOMUNIKASI DENGAN DVOR MONITOR MAUPUN AUDIO GENERATOR. BERKOMUNIKASI DENGAN ALAT DILUAR DVOR SYSTEM (RSCU,RMM).
13. LOW VOLTAGE POWER SUPPLY (LVPS)
ADA 3 BUAH CARD (1A14, 1A15, 1A16) YANG MENGHASILKAN TEGANGAN +/- 12 V DAN +5 VDC UNTUK MENSUPLY TEGANGAN RENDAH : 1A14 = SCIP
1A15 = TX1
1a16 = TX2
14. BATTERY CHARGER POWER SUBSYSTEM (BCPS)
BERFUNGSI SEBAGAI UPS DENGAN O/P +28 VOLT DAN +43/48 VOLT.
15. COMMUTATOR RACK
LOW VOLTAGE POWER SUPPLY (2A1A1)
UNTUK SUPPLY ELEKTRONIK DEVICE PADA COMMUTATOR RACK
COMMUTATOR CARD
TERDIRI DARI DUA BUAH (ATAS DAN BAWAH). ATAS UNTUK ANTENNA GANJIL DAN BAWAH UNTUK ANTENNA GENAB.
PIN DIODE DRIVER
ADA DUA CARD YANG TERHUBUNG KE COMMUTATOR YANG BERFUNGSI SEBAGAI MASTER SLAVE.
16. ANTENNA
ANTENNA SB TERDIRI DARI 48 BUAH TERPASANG MELINGKAR DENGAN DIAMETER 44 FOOT DENGAN SYSTEM ALFERD LOOP.
ANTENNA CARRIER TERLETAK DITENGAH DENGAN SISTEM ALFORD LOOP.
V. TEST POINT.
(HINDARI SEBISA MUNGKIN TINDAKAN MANUAL ADJ. LAKUKAN PERUBAHAN DENGAN MENGGUNAKAN RMM.
A. RF GENERATOR.
TP1 USB VCXO CONTROL VOLTAGE.
BENTUK PULSA:
DC LEVEL : 1,9 S/D 11 VDC (TX1=9VDC, TX2=7,12VDC)
RMM : -
MANUAL ADJ : C11, L5
FUNGSI : CEK KESTABILAN FREQ USB. MONITOR PADA
MENU E APAKAH FREQ USB LOCK ATAU UN
LOCK.. BILA UN LOCK 9960 HZ DEVIASI TIDAK
PADA POSISI 16.
TP2LSB VCXO CONTROL VOLTAGE
SAMA DENGAN USB (TX1=4,8 VDC TX2=6,16 VDC)
TP3CARR TO SB PHASE CONTROL VOLTAGE
DC LEVEL : 9 11 VDC (TX1=6,4VDC TX2=8,5VDC)
RMM: G;1/G;2,11
MANUAL ADJ: -
FUNGSI: MERUBAH PHASE REFF TERHADAP SB. SEBAGAI
PATOKAN UKUR TEGANGAN PADA TP3 ETELAH
KALIBRASI.
TP4MEAN PHASE ERROR VOLTAGE FOR CARRIER
DC LEVEL; 0 VDC 0.5 VDC
RMM: -
MANUAL ADJ: R54
FUNGSI: CONTROL PHASE FREQ CARR. BILA TEGANGAN DILUAR TOLERANSI BERARTI PHASE RF CARR TIDAK DAPAT DICONTROL SECARA AUTOMATIC. LAKUKAN PERUBAHAN PADA R54 UNTUK 0 VDC.
TP5MEAN PHASE ERROR CONTROL VOLTAGE FOR CARRIER.
DC LEVEL: 11 VDC (TX1=2,48VDC TX2=8VDC)
RMM; -
MANUAL ADJ;
FUNGSI; ?
TP6DYNAMIC PHASE CONTROL VOLTAGE FOR CARRIER
BENTUK PULSA:
DC LEVEL: 4 VDC (TX1=3VDC TX2=2,7VDC)
RMM: -
MANUAL ADJ: R 63
FUNGSI: SAMA DENGAN TP 4 (LOCK PHASE CARR)
TP7LSB QUARDATURE SIGNAL
BENTUK PULSA:
DC LEVEL: 0 VDC
RMM: G;1/G;2,9
MANUAL ADJ: R 100 ( ADJ POWER SB)
FUNGSI: MEMONITOR PHASE SB LSB SIN DAN COS SB 1 SB2. BILA PUNCAK BAWAH = 0 VOLT BERARTI PHASE LSB SIN COS SUDAH BENAR, BILA DI LUAR ITU MAKA PHASE TIDAK BENAR.
BILA PUNCAK ATAS TIDAK RATA MAKA POWER SB1 DAN 2 TIDAK SAMA LAKUKAN PERUBAHAN DENGAN MERUBAH POWER TIAP SB 1 DAN 2 PADA R100.
TP8LSB QUARDATURE SIGNAL
BENTUK PULSA:
DC LEVEL: 0 VDC
RMM: G;1/G;2,10
MANUAL ADJ; R 100 (ADJ POWER SB)
FUNGSI: SAMA DENGAN TP 7, TETAPI UNTUK SB 3 DAN SB 4.
TP 9GROUND
KETERANGAN : TP1 DAN TP2 TIAP DAERAH/DVOR BERBEDA. TERGANTUNG PADA FREQ CARRIER. UNTUK KEPASTIAN BUAT DAFTAR/CEK TP1 DAN 2 SETELAH KALIBRASI. DAN BILA DALAM PENGECEKAN RUTIN TERJADI PERUBAHAN BERARTI ADA KELAINAN.
B. SIDE BAND GENERATOR ASSY
TP1 / TP10DINAMIC PHASE CONTROL
BENTUK PULSA:
DC LEVEL: 4 VDC
RMM
: -
MANUAL ADJ: R102, R51, R97
FUNGSI
: R102 = SET DC LEVEL 4 VDC
R51 = SET BENTUK PULSA AGAR TIDAK
CACAD.
R97 = SET PULSA PTP (PEAK TO PEAK) = 3 V
TP2 / TP9MANUAL PHASE CONTROL
DC LEVEL: 10 VDC (TX1/TX2=8-8,6 VDC)
RMM: G;1/G;2, 9 & 10
FUNGSI: MANUAL CONTROL PHASE LEWAT RMM. SAMA FUNGSI DENGAN TP7 DAN TP 8 PADA RF GENERATOR.
TP3 / TP8MEAN PHASE CONTROL
DC LEVEL: 10 VDC (TX1/TX2=7.3 8 VDC)
MANUAL ADJ; R73
FUNGSI;
TP4 / TP7MEAN PHASE ERROR
DC LEVEL; 0 VDC (-2 VDC S/D +2VDC)
RMM
: -
MANUAL ADJ: R 73
FUNGSI
:
TP5 / TP6DETECTED O/P
BENTUK PULSA:
DC LEVEL: 0 VDC
RMM
: G;1/G;2,8
MANUAL ADJ: R100
FUNGSI
: MERUBAH MODULASI DENGAN MERUBAH POWER SB. BILA POWER SBTURUN MAKA MODULASI SB TURUN. INI DILIHAT DARI PTP PULSA AKAN BERUBAH.
J1-J4= O/P SB
C. AUDIO GENERATOR CARD
TP1AUDIO I/P LEVEL (VOICE)
TP2COMPOSITE AUDIO SIGNAL (VOICE)
TP3AMPLIFIED AUDIO LEVEL(VOICE)
TP4VOICE SIGNAL
TP5VOICE
TP6REFRENCE MOD SIGNAL
BENTUK PULSA:
DC LEVEL: 1,6 VDC (TERGANTUNG SETTING POWER)
RMM
: G;1 / G;2,2
FUNGSI
: - LIHAT SIGNAL 30 HZ REFF + IDENT
- BILA POWER PANCAR DIRUBAH MAKA DC LEVEL AKAN BERUBAH.
TP7360 HZ SIN
BENTUK PULSA:
MANUAL ADJ: R71 (FACTORY ADJ. JANGAN DI ADJ)
TP8360 HZ COS
BENTUK PULSA:
MANUAL ADJ: R71 (FAC ADJ. JANGAN DI ADJ)
TP9IDENT
TP10REFF SIGNAL 30 HZ
BENTUK PULSA:
RMM
: G;1 / G;2,7
FUNGSI
; LIHAT PULSA 30 HZ. BILA MOD DI RUBAH,LEVEL PULSA BERUBAH.
TP11NOT USED
J5WATT METER( PWR LEVEL SET PADA O/P CSB AMP)
D. MONITOR CARD
TP1 TP2NOISE O/P
TP3TONE/VOICE
TP4PULSA DETECTED VOICE
TP5COMPOSITE SIGNAL
TP630 HZ 30 REFF MOD (HALF WAVE)
BENTUK PULSA:
FUNGSI
: TP6 DIBANDINGKAN DENGAN TP13 (30 HZ VAR). BILA MENGGUNAKAN FIELD ANT. UTARA, PULSA 30 HZ VAR DAN REFF HARUS SEPHASE (ITU BILA ANT FIELD UTARA BENAR-BENAR TEPAT DI UTARA)
TP730 HZ REFF MOD (SQUARE)
BENTUK PULSA:
FUNGSI
: SAMA DENGAN TP6
TP8TONE MORSE CODE IDENT LEVEL
TP9STATUS IDENT
BENTUK PULSA;
TP10LEVEL MOD IDENT
BENTUK PULSA :
FUNGSI: UKURAN YANG MENYATAKAN FREQ IDENT 1020 HZ.
TP119960 HZ
BENTUK PULSA :
FUNGSI
: UKURAN YANG MENYATAKAN FREQ 9960 HZ ATAU BUKAN.
TP 12 9960 HZ SQUARE
TP13 30 HZ VAR (BENTUK PULSA=TP6)
TP14LEVEL MOD 9960HZ
DC LEVEL: 2.5 VDC
FUNGSI
: DC LEVEL MEWAKILI DARI % MOD DARI 30HZ VAR DVOR.
TP1530 HZ VAR SQUARE (FUNGSI SAMA DENGAN TP 7)
TP 16200 HZ CLOCK
TP 17VOLTAGE REFF 5 VDC.
CATATAN: SEBELUM CEK MONITOR CARD, PASTIKAN BAHWA I/P DB DARI FIELD DETECTOR = 0 DB. YAITU DENGAN MENGUKUR PADA O/P TP1-4 = 2.5 VOLT = 0 DB (POSISI PADA SAMPING COMUTATOR)
E. RF MONITOR PANEL
TP1DETECTED COMPOSITE SIGNAL
TP2SB1 REFLECTED POWER
TP3SB2 REFLECTED POWER
TP4SB3 REFLECTED POWER
TP5SB4 REFLECTED POWER
BENTUK PULSA:
TP6TX1 FWD PWR
TP7TX2 FWD PWR
BENTUK PULSA;
TP8TX1 REFL PWR
TP9TX2 REFL PWR.
BENTUK PULSA;
PAGE 1Panduan DVOR ASII-KUPANG
_1098518401.xlsSheet1
NOCHECK ITEMMENUTINDAKANAKIBATKETERANGAN
130 HZ REFF MODG;1 / G;2,7ANGKA DITAMBAHMODULASI NAIKPERUBAHAN
ANGKA DIKURANGIMODULASI TURUNSEKETIKA
29960 HZ atauG;1 / G;2,8ANGKA DITAMBAHMODULASI NAIKPERUBAHAN
ANGKA DIKURANGIMODULASI TURUNSEKITAR 1 MNT
G;1 / G;2,2ANGKA DITAMBAHMODULASI TURUNKARENA MOD
ANGKA DIKURANGIMODULASI NAIKDI UDARA
3.MOD IDENTG;1 / G;2,6ANGKA DITAMBAHMODULASI NAIK
ANGKA DIKURANGIMODULASI TURUN
4AZ INDEXG;1 / G;2,1ANGKA DITAMBAHAZ MAKIN BERTAMBAH
ANGKA DIKURANGIAZ BERKURANG