TANK SYSTEM - eckoeffendi.files.wordpress.com · Tipe Produksi AQUACULTURE ... 50l/min. berapa...
-
Upload
duongkhanh -
Category
Documents
-
view
227 -
download
7
Transcript of TANK SYSTEM - eckoeffendi.files.wordpress.com · Tipe Produksi AQUACULTURE ... 50l/min. berapa...
10/2/2012
1
TANK SYSTEM
Eko Efendi AQUACULTURE ENGINEERING
1
Eko Efendi AQUACULTURE ENGINEERING
2
10/2/2012
2
Tujuan Utama
Menciptakan Volume yang
dibatasi dimana ikan atau
organisme akuatik lainnya
dapat di beri makan pada
lingkungan air yang baik.
Eko Efendi AQUACULTURE ENGINEERING
3
Sistem yang Ekonomis
1. Asupan air, termasuk oksigen terlarut dalam air harus didistribusikan secara merata keseluruh unit produksi
2. Ikan harus tersebar merata pada total volume produksi
3. Ikan harus ditransportasikan secara efektif di dalam atau di luar unit
4. Unit harus memiliki kebutuhan pembersihan manual yang minimum
5. Lapisan permukaan dalam harus halus dan membutuhkan perawatan dan pembersihan yang sedikit
6. Unit harus mudah dioperasikan yang berarti mudah dibersihkan, memudahkan pemindahan ikan mati dan penanganan yang lain
7. Unit harus memiliki biaya investasi yang rendah tiap unit volume
Eko Efendi AQUACULTURE ENGINEERING
4
10/2/2012
3
Eko Efendi AQUACULTURE ENGINEERING
5
Eko Efendi AQUACULTURE ENGINEERING
6
10/2/2012
4
Tipe produksi
Eko Efendi AQUACULTURE ENGINEERING
7
Tipe Produksi
Eko Efendi AQUACULTURE ENGINEERING
8
10/2/2012
5
Tipe Produksi
Eko Efendi AQUACULTURE ENGINEERING
9
Kebutuhan Penggantian Air
• Memberi akses oksigen dan membuang hasil ekresi
• Tergantung:
1) Spesies,
2) Kepadatan,
3) Tingkat pertumbuhan,
4) Laju pertumbuhan,
5) Temperatur,
6) Kebutuhan akan oksigen murni atau tidak
7) Pembersihan otomatis atau manual.
Eko Efendi AQUACULTURE ENGINEERING
10
10/2/2012
6
Laju Penggantian Air
Laju Pertukaran air
mengindikasikan seberapa cepat
air berganti, atau dapat
didefinisikan sebagai periode dari
setiap molekul air tertinggal
didalam unit sebelum
meninggalkan melalui outlet
Air baru akan bercampur dengan
air lama, outlet berisi keduanya,
ARTINYA APA?
Eko Efendi AQUACULTURE ENGINEERING
11
Laju Pergantian Air
• 𝐹 = 1 − 𝑒−𝑡
𝑡ℎ 𝑥 100
• Dimana :
• t adalah waktu setelah mulai pengisian air
• th waktu yang diperlukan untuk mengisi volume 1 tank
pada laju lairan aktual atau juga dikenal sebagi wakyu
tinggal teoritis
• F adalah laju pergantian air (proporsi volume air dalam
unit yang ditukar setelah waktu t)
Eko Efendi AQUACULTURE ENGINEERING
12
10/2/2012
7
Laju Pergantian Air
• 50 liter air baru ditambahkan kedalam tank yang berisi 1001 air
digambarkan sebagi air lama, selama periode 5 menit (yakni 10 l/menit).
Jumlah yang sama air lama mengalir keluar melalui outlet karena volume
dan ketinggian air konstan. Berapa banyak volume yang ditukar setelah 5
dan 10 menit?
Setting t = 5min
th = 100l/(10 l/min) = 10min
F = (1 − e−5/10) × 100
= (1 − 0.605) × 100
= 39.5%
Setting t = 10min
F = 63.2%
Ini berarti bahwa penambahan air yang volumenya sama dengan volume tank
hanya 63,2% yang berganti, tidak semua sama dengan yang diharpakan,
dengan alasan bahwa air baru dan lama bercampur.
Eko Efendi AQUACULTURE ENGINEERING
13
TANK DESIGN
• What is important when choosing is that the new water is
uniformly distributed throughoutthe entire tank volume.
Eko Efendi AQUACULTURE ENGINEERING
14
10/2/2012
8
TANK DESIGN
When selecting a tank design, it is also important to take into account the utilization
of the area; square tanks with cut corners utilize this well, achieving several m3 of
farming volume per m2 surface area
Eko Efendi AQUACULTURE ENGINEERING
15
TANK DESIGN
The bottom of the tank could be horizontal or have
a small slope towards the outlet which is usually in
the centre of the tank.
The height of the tank compared to the diameter will also
affect the water exchange. For tanks with a circular flow
pattern, a tank diameter: height ratio of between 2 and 5
has been successfully used.
It is important that there is a smooth surface inside the
tank to reduce problems with fouling, and that the material
does not release any toxic substances into the farming
water
Eko Efendi AQUACULTURE ENGINEERING
16
10/2/2012
9
TANK DESIGN
Eko Efendi AQUACULTURE ENGINEERING
17
FLOW PATTERN
Eko Efendi AQUACULTURE ENGINEERING
18
10/2/2012
10
FLOW PATTERN
Eko Efendi AQUACULTURE ENGINEERING
19
WATER INLET DESIGN
The impulse, as the force caused by
the inlet water is called, depends on
the water flow and water velocity; it
can be xpressed as follows for tanks
with a circular flow pattern:
However, the increased velocity will increase the turbulence and hence the head
loss. Recommended values are below 1.5m/s in the inlet pipe, while the velocity in
the hole (or split or nozzle) should be below 1.2m/s
Eko Efendi AQUACULTURE ENGINEERING
20
10/2/2012
11
WATER INLET DESIGN
The velocity of the inlet water out of the holes or nozzles in the inlet
pipe (V2) depends on the design of the nozzle (hole), the area and the
amount of water that has to pass.
The relation between the water velocity in the inlet pipe and the
velocity out of the nozzles will be as follows
Eko Efendi AQUACULTURE ENGINEERING
21
WATER INLET DESIGN
Sebuah pipa pemasukan air pada tank sirkular didesain dengan debit
water flow (Q) 50l/min. berapa diameter pipa ideal dan lubang nozzle.
Hitung luas pipa inlet
Hitung diameter
Menggunakan standar terdekat
1 inchi
Eko Efendi AQUACULTURE ENGINEERING
22
10/2/2012
12
WATER INLET DESIGN
Hitung total luas (luas potongan melintang) menggunakan kecepatan
1.2m/s.
Harus dibagi menjadi jumlah lubang yang digunakan
Eko Efendi AQUACULTURE ENGINEERING
23
WATER OUTLET
1. to remove the Waste from the tank as quickly as possible, before the
leakage of nutrient starts;
2. to maintain the correct water level inside the tank
Correct design of the outlet is also important for the water exchange rate and to
ensure effective self-cleaning. Incorrect specification of the outlet system or the
outlet pipe may result in settling of uneaten feed particles and faeces, and the
outlet system will function as a settling basin.
The outlet pipe should be designed for water velocities above 0.3 m/s to ensure
no settling of solids. Velocities above 1.5 m/s in the outlet will result in rough
treatment of the particles which may break up. This makes later filtration of the
outlet water more difficult.
Eko Efendi AQUACULTURE ENGINEERING
24
10/2/2012
13
WATER OUTLET
Suplai air pada tank dengan volume 6m3 harus antara
60 dan 200 l/min. tentukan diameter pipa outlet yang
sesuai!
Pilih kecepatan 0.5m/s dan
hitung jumlah air terkecil
Hitung kecepatan air dalam
pipa dengan jumlah air terbesar
jika jari-jari pipa adalah 2.5 cm.
Eko Efendi AQUACULTURE ENGINEERING
25
Ketika mendesain sistem pembuangan sangatlah penting untuk
menciptakan geseran air, sehingga partikel yang mengendap didekat
outlet akan dipaksa keluar dengan mengurangi tekanan.
Eko Efendi AQUACULTURE ENGINEERING
27
10/2/2012
14
WATER OUTLET
Eko Efendi AQUACULTURE ENGINEERING
28
NEXT LEVEL…………..
Eko Efendi AQUACULTURE ENGINEERING
29