Solar Gard® Antimicrobial Film with BioCote® TechnologyConstant protection for a changing world.
TECHNOLOGYWITH
StephanieTypewritten textFor more information contact our approved Supplier/Distributor/Installer
,,PENTAGON FILMTEK
+971 50 153 3522 +971 432 50798
-
DID YOU KNOW?Every day we come into contact with millions of invisible microorganisms, including bacteria, mold and fungi. These microbes can have negative effects on products, including odors, staining and material degradation that can lead to early product failure.
A N T I M I C R O B I A L P R O D U C T S
Solar Gard® 4 Mil AMSOLAR GARD ANTIMICROBIAL FILMSDesigned to be easily replaced, Solar Gard Antimicrobial Films provide a virtually invisible barrier that protects flat surfaces from permanent damage. They also feature BioCote® proprietary silver ion technology, which is applied during the manufacturing process of these films. Silver’s scientifically proven antimicrobial properties protect these films from the negative effects of microbes by inhibiting their growth on the protected film’s surface. With a long history of success as an antimicrobial, silver is one of the most widely used technologies in the world.
Saint-Gobain Solar Gard partners with BioCote® Ltd to produce Antimicrobial Films. The BioCote® technology reduces microbial activity the moment microbes come in contact with the surface, protecting the film from odor- and stain-causing microbes to keep it cleaner and fresher for longer. The technology supplied by BioCote® is registered with the EPA and under review with the BPR*.
BioCote® is a registered trademark of BioCote Limited.
Built-in UV inhibitors Prevents expensive surface replacement
Long term antimicrobial protection
EN 45545 tested
Invisible antimicrobial protection
Scratch Resistant Removable adhesive Easily Installed
Invisibly removed
Optically clear
Features and benefits:
The removable adhesive allows for easy film removal and replacement.
*The Biocidal Products Regulation (BPR, Regulation (EU) 528/2012) concerns the placing on the market and use of biocidal products, which are used to protect humans, animals, materials or articles against harmful organisms like pests or bacteria, by the action of the active substances contained in the biocidal product.
Where can Antimicrobial films be installed?• Glass & other smooth surfaces • Entryways
• Monitor & device screens • Countertops
• Retail display cases & surfaces• Walls and partitions
• Elevators & escalators• Mass transit
Every Solar Gard film protected with BioCote® is independently tested to ensure its continued effectiveness in reducing levels of microbes and bacteria such as MRSA, E.coli by up to 99.99%. The technology is not a substitute for good hygiene and/or cleaning practice.
Note: Hexagon overlay is to show positioning of film. The film itself is completely clear.
Antimicrobial coating with silver ions
4 mil single layer of high-tensile strength PET film with high optical clarity and light transmission
Removable pressure-sensitive (PS) adhesive
-
• Water Yes
• Mild acids Yes
• Disinfectants Yes
(e.g. Lysol®, Optisal®, Kohrsolin®, Umonium38®)
• Salts and alkaline Yes
• Oils Yes
• Solvents Yes
• Petroleum-based grease Yes
RESISTANCE OF HARDCOAT TO CLEANING AGENTS:
SPECIFICATIONS Film Visible Light Haze Clarity (%) 1 Hardcoat Scratch Antimicrobial Properties Sample Transmittance (%)1 Factor (%) 1 Hardness 2 Resistance 3 Reduction Compared to Initial (%) 4
SG Antimicrobial Film >90 .80 >99 6H Pass MRSA >99%
E. coli >99%
1 Test method: ASTM D1003 2 Test method: ASTM D3363 3 Resistance to steel wool 4 Test method: ISO 22196
ANTIBACTERIAL ACTIVITY ANALYSIS
Contact time Percent reduction
24 hours 99,4% 2
24 hours
S. aureus
E. coli 99,9% 3
Source: Intertek. Report number: 104448801COL-003. JIS Z 2801/ISO 22196:2011 - Measurement of antibacterial activity on plastics and other non-porous surfaces
Test on SG Antimicrobial Film R
WATCH VIDEO
Solar Gard 4 mil AM has a limited lifetime warranty of 5 years (interior application) and 2 years when vertically applied outside. The anti-microbial function remains active as long as the surface remains undamaged. For details see GST&C and warranty conditions.
Reaction to fire classification according to EN 45545-2:2013+A1:2015/EN 45545-2:2020: R1 – HL1; HL2; HL3.
Learn more about Solar Gard Antimicrobial Films by contacting us today at +971 501 533522 or emailing [email protected]
-
Certificate of Analysis
According to ISO 22196: 2011
Latest version
MICROBIOLOGICAL PERFORMANCE TEST REPORT
Saint-Gobain Solar Gard LLC Intertek Report: No: 104448801COL-003
Version: 6-July-2017 Page 3 of 3 GFT-OP-10h
1. 4mil Antimicrobial Film – TL3-AM PET Lot# 5404071
S. aureus Results E. coli Results Test Parameter Result Test Parameter Result
Initial U0 5.97 Initial U0 5.72 24 Hr Ut 3.19 24 Hr Ut 4.11 24 Hr At 1.00 24 Hr At 1.00
Antibacterial Activity Value 2.19
Antibacterial Activity Value 3.11
Percent Reduction 99.4% Percent Reduction 99.9%
Note: Antibacterial Activity Values are presented in Log form as per standard requirements. A value of 1.00 would equate to a 90% reduction. A 2 would be 99%, a 3 99.9% and so forth.
Test Performed by: Report Approved by:
Allison Coyle Nicholas Unger Chemist Staff Engineer Columbus Office Columbus Office
StephanieTypewritten textApproved Suppliers and Installers ofSolar Gard Antimicrobial Films+971 501 533522 +971 432 [email protected]