PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP ....

17
LOGO PERANCANGAN INSTALASI ESP Pemilihan Pompa ESP Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical Dynamo of Arutunoff). 1. Seri dan Tipe Pompa ESP 2. Jumlah Stage (Number of Stage) Data performance pompa ESP stage head TDH Stage / 3. Pump Mechanical Strength l pump Stage stage BHP BHP 4.Maximum Internal Housing Pressure l grad Stage stage head p max max

Transcript of PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP ....

Page 1: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

PERANCANGAN INSTALASI ESP Pemilihan Pompa ESP

Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical

Dynamo of Arutunoff).

1. Seri dan Tipe Pompa ESP

2. Jumlah Stage (Number of Stage)

Data performance pompa ESP

stagehead

TDHStage

/

3. Pump Mechanical Strength

lpump Stagestage

BHPBHP

4.Maximum Internal Housing Pressure lgradStagestage

headp

max

max

Page 2: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

PERANCANGAN INSTALASI ESP Pemilihan Protector

1. Seri dan Tipe Protector

Pemilihan protector menggunakan protector buatan REDA

2. Gaya Thrust Maximum

2max785.0 dpFTB

Page 3: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

PERANCANGAN INSTALASI ESP Pemilihan Motor ESP

1. Seri dan Tipe Motor ESP

2. Kecepatan Aliran di Sekitar Motor

22

'

0119.0mc

ll

ODID

qv

3. Arus Motor Aktual

np

system

npHP

BHPII

Page 4: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

PERANCANGAN INSTALASI ESP

Pemilihan Kabel

1. Panjang Kabel

2. Jenis & Ukuran Kabel

3. Biaya Instalasi Kabel

PSD + 100 ft

Katalog REDA

Page 5: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

PERANCANGAN INSTALASI ESP Memeriksa Startup Motor

np

Tnp

np

start

U

IRU

U

U 4 Ukuran kabel yang dipilih adalah aman jika

rasio ini lebih besar dari 0,5 (50%)

dan startup tidak akan terjadi masalah

Pemilihan Switchboard dan Transformer

1. Tegangan Permukaan

2. Rating Daya

IRUU Tnpsurf 732.1

IUIU

P surf

surf

surf 001732.01000

3

Page 6: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

METODE PERANCANGAN

Studi Kasus 1

Studi Literatur 2

Menentukan data-data yang diperlukan 3

Penyusunan Tugas Akhir 4

Page 7: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

ANALISIS DAN PERHITUNGAN

Data

Pump Setting

Depth (PSD)

Kondisi Sumur IPR

Laju Produksi

Instalasi Sistem

ESP

Page 8: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

DATA

Well Data

Casing (in) 9,625

ID Tubing (in) 2,992

Flowline pressure (psia) 250

Depth (ft) 4750

Perforasi MD (ft) 4632-4647 4660-4674 4681-4711 4732-4750

Productivity Index (PI) 6 BPD/psi

Fluid Data

Oil API 40

SG Oil 0,825

SG gas 0,967

SG Water 1

Oil viskosity (cp) 1,59

Water viskosity (cp) 0,4

GOR (scf/stb) 70

T (F) 250

Production Data

Pr (psia) 1200

Pb (psia) 400

10 July 2010

Pwf (psia) 800

Q liq (BPD) 2400

WC 60%

Q oil (BPD) 960

Q water (BPD) 1440

Page 9: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

Pr (psia) Pwf (psia) q (bpd) WFL (ft) Water cut (%)

1200 0 6133 0 60

1200 50 6083 124,2 60

1200 100 6000 248,3 60

1200 150 5883 372,5 60

1200 200 5733 496,6 60

1200 250 5550 620,8 60

1200 300 5333 745 60

1200 350 5083 869,1 60

1200 400 4800 993,3 60

1200 450 4500 1117 60

1200 500 4200 1242 60

1200 550 3900 1366 60

1200 600 3600 1490 60

1200 650 3300 1614 60

1200 700 3000 1738 60

1200 750 2700 1862 60

1200 800 2400 1987 60

1200 850 2100 2111 60

1200 900 1800 2235 60

1200 950 1500 2359 60

1200 1000 1200 2483 60

1200 1050 900 2607 60

1200 1100 600 2732 60

1200 1150 300 2856 60

1200 1200 0 2980 60

ANALISIS IPR

Pwf (Psi)

q (BPD)

IPR WELL XX

Bubblepoint Pressure

Page 10: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

ANALISIS KONDISI SUMUR

Bubble-point Pressure Di Sumur 2

Jumlah Kandungan Gas Di Sumur 3

Karakteristik Fluida Di Sumur 1

Page 11: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

KARAKTERISTIK FLUIDA DI SUMUR

Page 12: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

KARAKTERISTIK FLUIDA DI SUMUR

Page 13: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

BUBBLE-POINT PRESSURE DI SUMUR

Bubble-point

Pb = 400 Psi

P < Pb = Saturated

P > Pb = Unsaturated

Page 14: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

BUBBLE-POINT PRESSURE DI SUMUR

Bubble-point/gelembung gas mulai lepas pada ketinggian 970 ft diatas perforasi Bubble-point lepas dari fase minyak SGwater > SGoil > SGgas Jadi diindikasikan bahwa ketinggian diatas 970 ft dari perforasi kandungan minyak lebih banyak

Page 15: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

JUMLAH GAS BEBAS DI SUMUR

Bubble-point/gelembung gas mulai lepas pada ketinggian 970 ft diatas perforasi Semakin keatas jumlah gas bebas semakin banyak Ketinggian lebih dari 970 ft dari perforasi, jumlah kandungan gas bebas (free gas) akan semakin banyak

Page 16: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

PUMP SETTING DEPTH (PSD)

Jumlah Gas Bebas di Sumur

Karakteristik Fluida di Sumur

Bubble-point Pressure di Sumur

Maka Pump Setting Depth (PSD) yaitu

Berdasarkan Analisis Kondisi Sumur

Page 17: PERANCANGAN INSTALASI ESP - digilib.its.ac.id · PERANCANGAN INSTALASI ESP. Pemilihan Pompa ESP . Pemilihan pompa ESP menggunakan pompa buatan REDA (Russian Electrical . Dynamo of

LOGO

PUMP SETTING DEPTH (PSD)

Pump setting depth (PSD) dari ESP yaitu sekitar 950 ft diatas

perforasi atau 3.800 ft dari permukaan tanah