Bahaya Listrik - K3
-
Upload
agusniefendi -
Category
Documents
-
view
194 -
download
26
Transcript of Bahaya Listrik - K3
BAHAYA LISTRIK BAGI MANUSIA BAHAYA LISTRIK BAGI MANUSIA
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-1
SHOCK (TERKEJUT)
SHOCK (TERKEJUT) PINGSAN
TERBAKARTERBAKAR
KEMATIANKEMATIAN
BAHAYA YANG DITIMBULKAN OLEH ARUS / TEGANGAN LISTRIK TERHADAP MANUSIA ADALAH :
BAHAYA YANG DITIMBULKAN OLEH ARUS / TEGANGAN LISTRIK TERHADAP MANUSIA ADALAH :
Doc:Anton/03/04/ags
DENYUT JANTUNG YANG TERSENGAT LISTRIKDENYUT JANTUNG YANG TERSENGAT LISTRIK
BAHAYA LISTRIK-2
KEADAAN NORMAL TERKENA SENGATAN LISTRIK
DENYUT NORMAL :
80 KALI PER MENIT ---> DIPERINTAHKAN 100KALI PER DETIK
PT PLN (Persero)UDIKLAT BOGOR
Doc:Anton/03/04/ags
PENGARUH MEDAN LISTRIK DAN MEDAN MAGNET TERHADAP MANUSIA :
MEDAN LISTRIK [KV / M] MEDAN MAGNET [mT]
MEDAN LISTRIK DAN MEDAN MAGNET DI TEMPAT KERJA :
SUTR, SUTM, SUTT, SUTET MESIN PENDINGIN, MESIN KETIK ELEKTRONIK, MESIN PENDINGI, MESIN PHOTO COPY MESIN LAS ALAT KERJA KOMPUTER DAN PRINTER MESIN KOMPRESOR, DAN LAIN-LAIN
PENGARUH MEDAN LISTRIK DAN MEDAN MAGNET TERHADAP MANUSIA :
MEDAN LISTRIK [KV / M] MEDAN MAGNET [mT]
MEDAN LISTRIK DAN MEDAN MAGNET DI TEMPAT KERJA :
SUTR, SUTM, SUTT, SUTET MESIN PENDINGIN, MESIN KETIK ELEKTRONIK, MESIN PENDINGI, MESIN PHOTO COPY MESIN LAS ALAT KERJA KOMPUTER DAN PRINTER MESIN KOMPRESOR, DAN LAIN-LAIN
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-3
Doc:Anton/03/04/ags
• MEDAN LISTRIK ADALAH SUATU MEDAN ATAU LAPANGAN YANG DAPAT MENIMBULKAN GAYA PADA PERTIKEL BERMUATAN LISTRIK YANG TERLETAK DALAM MEDAN TERSEBUT.
• MEDAN LISTRIK ITU SENDIRI TIMBUL OLEH ADANYA PARTIKEL BERMUATAN LISTRIK ATAU DENGAN KATALAIN OLEH ADANYA TEGANGAN LISTRIK
• MEDAN LISTRIK BERKURANG KEKUATANNYA SELARAS DENGAN BERTAMBAHNYA JARAK DARI SUMBER SATUAN DARI MEDAN LISTRIK ADALAH [Kv/M].
• MEDAN LISTRIK ADALAH SUATU MEDAN ATAU LAPANGAN YANG DAPAT MENIMBULKAN GAYA PADA PERTIKEL BERMUATAN LISTRIK YANG TERLETAK DALAM MEDAN TERSEBUT.
• MEDAN LISTRIK ITU SENDIRI TIMBUL OLEH ADANYA PARTIKEL BERMUATAN LISTRIK ATAU DENGAN KATALAIN OLEH ADANYA TEGANGAN LISTRIK
• MEDAN LISTRIK BERKURANG KEKUATANNYA SELARAS DENGAN BERTAMBAHNYA JARAK DARI SUMBER SATUAN DARI MEDAN LISTRIK ADALAH [Kv/M].
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-4
MEDAN LISTRIKMEDAN LISTRIK
Doc:Anton/03/04/ags
• MEDAN MAGNET ADALAH SUATU MEDAN ATAU LAPANGAN YANG DAPAT MENIMBULKAN GAYA PADA BENDA-BENDA MAGNET ATAU PARTIKEL BERMUATAN LISTRIK.
• MEDAN MAGNET DITIMBULKAN OLEH BENDA-BENDA MAGNET ATAU KONDUKTOR YANG DIALIRI ARUS LISTRIK
• ADA BEBERAPA BESARAN DARI MEDAN MAGNET, SALAH SATUNYA ADALAH INDUKSI MEDAN MAGNET ATAU RAPAT FLUKS MAGNET.
• SATUANNYA T (TESLA) ATAU G (GAUSS) ATAU Wb/m2 (WEBER/METER PERSEGI)
• MEDAN MAGNET ADALAH SUATU MEDAN ATAU LAPANGAN YANG DAPAT MENIMBULKAN GAYA PADA BENDA-BENDA MAGNET ATAU PARTIKEL BERMUATAN LISTRIK.
• MEDAN MAGNET DITIMBULKAN OLEH BENDA-BENDA MAGNET ATAU KONDUKTOR YANG DIALIRI ARUS LISTRIK
• ADA BEBERAPA BESARAN DARI MEDAN MAGNET, SALAH SATUNYA ADALAH INDUKSI MEDAN MAGNET ATAU RAPAT FLUKS MAGNET.
• SATUANNYA T (TESLA) ATAU G (GAUSS) ATAU Wb/m2 (WEBER/METER PERSEGI)
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-5
MEDAN MAGNETMEDAN MAGNET
Doc:Anton/03/04/ags
POLA MEDAN LISTRIK DAN MEDAN MAKNITDARI SUATU KONDUKTOR YANG MENGALIRKAN ARUS LISTRIK
POLA MEDAN LISTRIK DAN MEDAN MAKNITDARI SUATU KONDUKTOR YANG MENGALIRKAN ARUS LISTRIK
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-6
+ +
KONDUKTOR BERTEGANGAN
MEDAN LISTRIK
MEDAN MAGNET
TANAH/BUMI TANAH/BUMI
Doc:Anton/03/04/ags
MEDAN LISTRIK MEDAN LISTRIK
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-7
• ANTARA IONOSFIR DAN PERMUKAAN BUMI : UDARA CERAH
100 500 VOLT / METER
• AWAN MENDUNG YANG MENGANDUNG POTENSIAL PETIR MEMBANGKITKAN MEDAN LISTRIK
3000 30.000 VOLT / METER
Doc:Anton/03/04/ags
MEDAN MAKNITMEDAN MAKNIT
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-8
MENYELIMUTI BUMI, KEKUATANNYA
40 70 microtesla
IT = 1000. mT ----> T = TESLA
IG = 1000. mG ----> G = GAUSS
IT = 10.000 . G.
Doc:Anton/03/04/ags
MEDAN LISTRIK PADA PERALATAN LISTRIK
MEDAN LISTRIK PADA PERALATAN LISTRIK
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-7
PERALATAN MEDAN LISTRIK
(VOLT / METER)
SELIMUT LISTRIK 250
STEREO SET 90
LEMARI PENDINGIN 60
SETRIKA LISTRIK 60
PENGERING RAMBUT 40
TV BERWARNA 30
16
LAMPU PIJAR 2
PENYEDOT DEBU
Doc:Anton/03/04/ags
MEDAN MAGNETPADA PERALATAN LISTRIK
MEDAN MAGNETPADA PERALATAN LISTRIK
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-10
MEDAN MAGNET ( T) PERALATAN
3 CMPERALATAN 30 CM 100 CM
6 - 2000PENGERING RAMBUT 0,01 - 7 0,01 - 0,3
15 - 1500ALAT CUKUR 0,08 - 5 0,01 - 0,3
4000 - 800BOR LISTRIK 2 - 3,5 0,08 - 0,2
60 - 700MIXER 0,6 - 10 0,02 - 0,025
2,5 - 50TELEVISI 0,04 - 2 0,01 - 0,15
8 - 30SETRIKA LISTRIK 0,12 - 0,3 0,01 - 0,025
0,5 - 1,7LEMARI PENDINGIN 0,01 - 0,25 < 0,01
Doc:Anton/03/04/ags
HASIL PENGUKURAN KUAT MEDAN MAGNET DI BAWAH SUTET 500 KV KRIAN- PAITON OLEH ITS
HASIL PENGUKURAN KUAT MEDAN MAGNET DI BAWAH SUTET 500 KV KRIAN- PAITON OLEH ITS
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-11
10
9
8
7
6
5
4
3
2
1
0
-25 -15 -12 -9 -7,5 -6 -3 0 3 6 7,5 9 12 15 25
AS TENGAH TOWERAmbang batas WHO = 1000 mG
MEDAN MAGNET Jarak Mendatar (m) Obyek Pengukuran : SUTT 500 kVlokasi Ds. Semambung KrianTgl. 13 Juli 1997waktu : Pkl. 15.30-16.30
Doc:Anton/03/04/ags
HASIL PENGUKURAN KUAT MEDAN LISTRIK DI BAWAH SUTET 500 KV KRIAN- PAITON OLEH
ITS
HASIL PENGUKURAN KUAT MEDAN LISTRIK DI BAWAH SUTET 500 KV KRIAN- PAITON OLEH
ITS
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-12
5
4
3
2
1
0
-25 -15 -12 -9 -7,5 -6 -3 0 3 6 7,5 9 12 15 25
AS TENGAH TOWERAmbang batas WHO = 5 kV/m
MEDAN LISTRIK Jarak Mendatar (m) Obyek Pengukuran : SUTT 500 kVlokasi Ds. Semambung KrianTgl. 13 Juli 1997waktu : Pkl. 15.30-16.30
Doc:Anton/03/04/ags
HASIL PENGUKURAN KUAT MEDAN MAGNET DI BAWAH SUTET 150 KV SAWAHAN BARAT OLEH ITS
HASIL PENGUKURAN KUAT MEDAN MAGNET DI BAWAH SUTET 150 KV SAWAHAN BARAT OLEH ITS
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-13
10
9
8
7
6
5
4
3
2
1
0
-25 -15 -12 -9 -7,5 -6 -3 0 3 6 7,5 9 12 15 25
AS TENGAH TOWERAmbang batas WHO = 1000 mG
MEDAN MAGNET Jarak Mendatar (m) Obyek Pengukuran : SUTT 150 kVlokasi Jl. Raya Darmo II SurabayaTgl. 13 Juli 1997waktu : Pkl. 17.00 - 17.30
Ku
at
Me
da
n
Ma
gn
et
(mG
)
Doc:Anton/03/04/ags
PEDOMAN NILAI AMBANG BATAS KUAT MEDAN LISTRIK DAN KUAT MEDAN MAGNET YANG
DIPAKAI PLN
PEDOMAN NILAI AMBANG BATAS KUAT MEDAN LISTRIK DAN KUAT MEDAN MAGNET YANG
DIPAKAI PLN
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-14
PERATURAN MEDAN LISTRIK MEDAN MAGNET
STANDAR PLN (SPLN NO. 112/1994)
INIRC MENGENAI PETUNJUK BATAS-BATAS PEMAPARAN TERHADAP MEDAN LISTRIK DAN MEDAN MAGNET (EMF) 50/60 HZ/REKOMENDASI WHO IRPS 1990
WORKING HOUR E (MAX) : 10 kV/m
CONTINOUSLY E (MAX) : 5 Kv/m
WORKING HOUR B (MAX) : 0,5 mt
CONTINOUSLY B (MAX)
: 0,1 mt
REFERENSI : KEPUTUSAN DIREKSI PT PLN (Persero) NO. 031.K/008/DIR/1997 TANGGAL 14 APRRIL 1997
Doc:Anton/03/04/ags
TEGANGAN YANG TIMBUL AKIBAT ARUS BOCOR / KESALAHAN KE TANAH TERHADAP ORANG YANG BERADA DI SEKITAR INSTALASI TENAGA LISTRIK :
• TEGANGAN SENTUH
• TEGANGAN LANGKAH
• TEGANGAN PINDAH
TEGANGAN YANG TIMBUL AKIBAT ARUS BOCOR / KESALAHAN KE TANAH TERHADAP ORANG YANG BERADA DI SEKITAR INSTALASI TENAGA LISTRIK :
• TEGANGAN SENTUH
• TEGANGAN LANGKAH
• TEGANGAN PINDAH
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-15
Doc:Anton/03/04/ags
TABEL : BESAR DAN LAMA TEGANGAN SENTUH MAKSIMUM
BESAR TEGANGAN SENTUH (V)
AC (RMS) DC
< 50 < 120
50 120
75 140
90 160
110 175
150 200
220 250
280 310
LAMA SENTUHAN
MAKSIMUM (DETIK)
-
5,0
1,0
0,5
0,2
0,1
0,05
0,03
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-16
Doc:Anton/03/04/ags
SESEORANG TIDAK BOLEH
MENYENTUH WALAU SEKEJAPPUN
PERALATAN DENGAN TEGANGAN DI
ATAS 100 VOLT
SESEORANG TIDAK BOLEH
MENYENTUH WALAU SEKEJAPPUN
PERALATAN DENGAN TEGANGAN DI
ATAS 100 VOLT
ATURAN UMUM : ATURAN UMUM :
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-17
Doc:Anton/03/04/ags
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-18
BATASAN BESARNYA ARUS LISTRIK YANG
MENGALIR MELALUI TUBUH MANUSIA SERTA
PENGARUH LANGSUNG YANG DIRASAKAN :
• ARUS PERSEPSI (PERCEPTION CURRENT)
• ARUS MEMPENGARUHI OTOT (LETGO CURRENT)
• ARUS FIBRILASI (FIBRILLATING CURRENT)
• ARUS REAKSI (REACTION CURRENT)
BATASAN BESARNYA ARUS LISTRIK YANG
MENGALIR MELALUI TUBUH MANUSIA SERTA
PENGARUH LANGSUNG YANG DIRASAKAN :
• ARUS PERSEPSI (PERCEPTION CURRENT)
• ARUS MEMPENGARUHI OTOT (LETGO CURRENT)
• ARUS FIBRILASI (FIBRILLATING CURRENT)
• ARUS REAKSI (REACTION CURRENT)
Doc:Anton/03/04/ags
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-19
PENGARUH ARUS LISTRIK PADA TUBUH MANUSIA
BESARNYA ARUS PENGARUH PADA TUBUH MANUSIA
BELUM DIRASAKAN PENGARUHNYA0 ……… 0,9 mA
BARU TERASA ADANYA ARUS LISTRIK0,9 ……… 1,2 mAMULAI TERASA SEAKAN-AKAN ADA YANG
MERAYAP DIDALAM TANGAN1,2 ……… 1,6 mA
TANGAN SAMPAI KESIKU MERASA KESEMUTAN 1,6 ……… 6,0 mA
TANGAN MULAI KAKU, RASA KESEMUTAN MAKIN BERTAMBAH6,0 ……… 8,0 mA
RASA SAKIT TIDAKTERTAHANKAN PENGHANTAR
MASIH DAPAT DILEPASKAN DENGAN GAYA YANG
BESAR SEKALI13 ……… 15,0 mA
OTOT TIDAK SANGGUP LAGI MELEPASKAN PENGHANTAR15 ……… 20,0 mA
DAPAT MENGAKIBATKAN KERUSAKAN PADA TUBUH MANUSIA20 ……… 50,0 mA
BATAS ARUS YANG DAPAT MENYEBABKAN KEMATIAN50 ……… 100,0 mA
Doc:Anton/03/04/ags
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-20
Doc:Anton/03/04/ags
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-21
JARAK BEBAS MINIMUM ANTARA PENGHANTAR SUTT DAN SUTET DENGAN TANAH DAN BENDA LAINJARAK BEBAS MINIMUM ANTARA PENGHANTAR SUTT DAN SUTET DENGAN TANAH DAN BENDA LAIN
Catatan :
NO LOKASI SUTT 66 KV (M)
SUTT 150 KV (M)
SIRKIT GANDA (M)
SIRKIT TUNGGAL (M)
SUTET 500 KV
LAPANGAN TERBUKA ATAU DAERAH TERBUKA
DAERAH DENGAN KEADAAN TERTENTU :
2.1. BANGUNAN TIDAK TAHAN API
2.2. BANGUNAN TAHAN API
2.3. LALU LINTAS JALAN / JALAN RAYA
2.4. POHON - POHON PADA UMUMNYA, HUTAN, PERKEBUNAN
2.5. LAPANGAN OLAH RAGA
2.6. SUTT LAINNYA, PENGHANTAR UDARA TM, JARINGAN TELEKOMUNIKASI, ANTENA RADIO, ANTENA TELEVISI DAN KERETA GANTUNG
2.7. REL KERETA BIASA
2.8. JEMBATAN BESI, RANGKA BESIPENAHAN PENGHANTAR, KERETA LISTRIK TERDEKAT DSB.
2.9. TITIK TERTINGGI TIANG KAPAL PADA KEDUDUKAN AIR PASANG / TERTINGGI PADA LALU LINTAS AIR
1
2
6,5
12,5
3,5
8
3,5
12,5
3
8
3
3
7,5
13,5
4,5
9
4,5
13,5
4
9
4
4
10
14
8,5
15
8,5
14
8,5
15
8,5
8,5
11
15
8,5
15
8,5
15
8,5
15
8,5
8,5
Doc:Anton/03/04/ags
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-22
PENELITIAN Dr. ANIES - UNIVERSITAS DIPENOGORO
(1993)
PENELITIAN Dr. ANIES - UNIVERSITAS DIPENOGORO
(1993)
DARI HASIL PENGUKURAN TERNYATA KUAT MEDAN LISTRIK DAN
KUAT MEDAN MAGNET DARI SUTT/SUTET MASIH JAUH DIBAWAH
AMBANG BATAS YANG DIREKOMENDASIKAN WHO/IRPA SEHINGGA
DALAM BATAS TERTENTU (DIATAS) SUTT/SUTET TIDAK AKAN
MENIMBULKAN MASALAH KESEHATAN, NAMUN KETAKUTAN SERTA
KEKHAHAWATIRAN MASYARAKAT ADALAH WAJAR DAN SEBAGAI
UPAYA UNTUK MEPERKECIL DAMPAK NEGATIF SUTT / SUTET
TERHADAP KESEHATAN MASYARAKAT, PERLU DILAKUKAN
PENYULUHAN YANG EFEKTIF KEPADA MASYARAKAT UMUM.
DARI HASIL PENGUKURAN TERNYATA KUAT MEDAN LISTRIK DAN
KUAT MEDAN MAGNET DARI SUTT/SUTET MASIH JAUH DIBAWAH
AMBANG BATAS YANG DIREKOMENDASIKAN WHO/IRPA SEHINGGA
DALAM BATAS TERTENTU (DIATAS) SUTT/SUTET TIDAK AKAN
MENIMBULKAN MASALAH KESEHATAN, NAMUN KETAKUTAN SERTA
KEKHAHAWATIRAN MASYARAKAT ADALAH WAJAR DAN SEBAGAI
UPAYA UNTUK MEPERKECIL DAMPAK NEGATIF SUTT / SUTET
TERHADAP KESEHATAN MASYARAKAT, PERLU DILAKUKAN
PENYULUHAN YANG EFEKTIF KEPADA MASYARAKAT UMUM.
Doc:Anton/03/04/ags
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-23
PENELITIAN SOSIOLOGI KASNODIHARDJO DAN SOESANTO (1995)PENELITIAN SOSIOLOGI KASNODIHARDJO DAN SOESANTO (1995)
PENELITIAN-PENELITIAN SOSIOLOGI KASNODIHARDJO DAN
SOESANTO (1995) DAN GANIHARTONO (1995), YANG BERUSAHA
MENILIK KEADAAN DAN HUBUNGAN SOSIAL EKONOMI DAN
GANGGUAN SUTET 500 KV YANG DIKELUHKAN PENDUDUK
DIDAERAH CIBINONG DAN BEKASI JAWA BARAT, TELAH
MENUNJUKAN BAHWA TIDAK ADA HUBUNGAN LANGSUNG ANTARA
KETERPAPARAN PENDUDUK YANG BERADA DIBAWAH JARINGAN
SUTET DENGAN PENYAKIT YANG DILAPORKAN ATAUPUN TINGKAT
KESEHATAN MASYARAKAT
PENELITIAN-PENELITIAN SOSIOLOGI KASNODIHARDJO DAN
SOESANTO (1995) DAN GANIHARTONO (1995), YANG BERUSAHA
MENILIK KEADAAN DAN HUBUNGAN SOSIAL EKONOMI DAN
GANGGUAN SUTET 500 KV YANG DIKELUHKAN PENDUDUK
DIDAERAH CIBINONG DAN BEKASI JAWA BARAT, TELAH
MENUNJUKAN BAHWA TIDAK ADA HUBUNGAN LANGSUNG ANTARA
KETERPAPARAN PENDUDUK YANG BERADA DIBAWAH JARINGAN
SUTET DENGAN PENYAKIT YANG DILAPORKAN ATAUPUN TINGKAT
KESEHATAN MASYARAKAT
Doc:Anton/03/04/ags
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-24
PENELITIAN BUDI HARYANTO SKM, MSc BALITBANG DEPKES RI
(1995/ 1996)
PENELITIAN BUDI HARYANTO SKM, MSc BALITBANG DEPKES RI
(1995/ 1996)
TIDAK ADA KORELASI ANTARA GANGGUAN KESEHATAN SEPERTI
SAKIT KEPALA, KELELAHAN SEPERTI SAKIT KEPALA, KELELAHAN
MENTAL, PUSING KEPALA, KEGUGURAN, SUSAH TIDUR,
BRADYCARDIA, TACHYCARDIA, INDIKASI TUMOR DAN LEUKIMIA
TERHADAP PAJANAN MEDAN LISTRIK DAN MEDAN MAGNET
TIDAK ADA KORELASI ANTARA GANGGUAN KESEHATAN SEPERTI
SAKIT KEPALA, KELELAHAN SEPERTI SAKIT KEPALA, KELELAHAN
MENTAL, PUSING KEPALA, KEGUGURAN, SUSAH TIDUR,
BRADYCARDIA, TACHYCARDIA, INDIKASI TUMOR DAN LEUKIMIA
TERHADAP PAJANAN MEDAN LISTRIK DAN MEDAN MAGNET
Doc:Anton/03/04/ags
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-25
PENELITIAN Ir. SYARIFUDIN MAHMUDSYAH M. Eng
FAKULTAS ELEKTRO- ITS
PENELITIAN Ir. SYARIFUDIN MAHMUDSYAH M. Eng
FAKULTAS ELEKTRO- ITS
DARI HASIL PENELITIAN MENGENAI DAMPAK MEDAN
ELEKTROMAGNETIK AKIBAT PEMAKAIAN TENAGA LISTRIK
KHUSUSNYA SUTT 150 KV / SUTET 500 KV PADA DAERAH
SINGOSARI GRESIK SERTA DHARMAHUSADA INDAH SURABAYA,
DARI HASIL PENGUKURAN MEDAN ELEKTROMAGNETIK AKIBAT
SUTT / SUTET DIPEROLEH DATA BAHWA KUAT MEDAN LISTRIK DAN
KUAT MEDAN MAGNET MASIH JAUH DIBAWAH LEVEL TOLERANSI
BERDASARKAN STANDAR IRPA DAN INRC. MASALAH YANG
DIHADAPI PENDUDUK LEBIH CONDONG KEPADA MASALAH
PSIKOLOGIS DAN TUNTUNAN MENDAPATKAN GANTI RUGI.
DARI HASIL PENELITIAN MENGENAI DAMPAK MEDAN
ELEKTROMAGNETIK AKIBAT PEMAKAIAN TENAGA LISTRIK
KHUSUSNYA SUTT 150 KV / SUTET 500 KV PADA DAERAH
SINGOSARI GRESIK SERTA DHARMAHUSADA INDAH SURABAYA,
DARI HASIL PENGUKURAN MEDAN ELEKTROMAGNETIK AKIBAT
SUTT / SUTET DIPEROLEH DATA BAHWA KUAT MEDAN LISTRIK DAN
KUAT MEDAN MAGNET MASIH JAUH DIBAWAH LEVEL TOLERANSI
BERDASARKAN STANDAR IRPA DAN INRC. MASALAH YANG
DIHADAPI PENDUDUK LEBIH CONDONG KEPADA MASALAH
PSIKOLOGIS DAN TUNTUNAN MENDAPATKAN GANTI RUGI.
Doc:Anton/03/04/ags
PT PLN (Persero)UDIKLAT BOGOR
BAHAYA LISTRIK-26
KERJASAMA LEMBAGA PENELITIAN MASYARAKAT ITB - FAKULTAS KEDOKTERAN UNIVERSITAS INDONESIA
(1996/ 1997)
KERJASAMA LEMBAGA PENELITIAN MASYARAKAT ITB - FAKULTAS KEDOKTERAN UNIVERSITAS INDONESIA
(1996/ 1997)
TIDAK ADA KORELASI FREKUENSI GANGGUAN KESEHATAN
MASYARAKAT YANG TERPAJAN MEDAN LISTRIK DAN MEDAN
MAGNET DARI SUTET BERHUBUNGAN DENGAN JARAK TEMPAT
TINGGAL TERHADAP JARINGAN, DAN JUGA TIDAK ADA PENGARUH
DARI BESAR DAN LAMANYA PEMAJANAN MEDAN LISTRIK DAN
MEDAN MAGNET TERHADAP DERAJAT KELAINAN FUNGSI SISTEM
TUBUH.
TIDAK ADA KORELASI FREKUENSI GANGGUAN KESEHATAN
MASYARAKAT YANG TERPAJAN MEDAN LISTRIK DAN MEDAN
MAGNET DARI SUTET BERHUBUNGAN DENGAN JARAK TEMPAT
TINGGAL TERHADAP JARINGAN, DAN JUGA TIDAK ADA PENGARUH
DARI BESAR DAN LAMANYA PEMAJANAN MEDAN LISTRIK DAN
MEDAN MAGNET TERHADAP DERAJAT KELAINAN FUNGSI SISTEM
TUBUH.
Doc:Anton/03/04/ags
BAHAYA LISTRIK-27
K E S I M P U L A N K E S I M P U L A N
DENGAN DEMIKIAN UNTUK
SEMENTARA DAPAT
DISIMPULKAN BAHWA SAMPAI
SAAT INI BESARNYA MEDAN
LISTRIK DAN MEDAN MAGNET
YANG BERADA DIBAWAH DAN
SEKITAR SUTT / SUTET YANG
ADA DI INDONESIA BELUM
MEMBAHAYAKAN BAGI
KESEHATAN PENDUDUK
DENGAN DEMIKIAN UNTUK
SEMENTARA DAPAT
DISIMPULKAN BAHWA SAMPAI
SAAT INI BESARNYA MEDAN
LISTRIK DAN MEDAN MAGNET
YANG BERADA DIBAWAH DAN
SEKITAR SUTT / SUTET YANG
ADA DI INDONESIA BELUM
MEMBAHAYAKAN BAGI
KESEHATAN PENDUDUK
PT PLN (Persero)UDIKLAT BOGOR
Doc:Anton/03/04/ags
BAHAYA LISTRIK PADA TEGANGAN TINGGI / EKSTRA TINGGIBAHAYA LISTRIK PADA TEGANGAN TINGGI / EKSTRA TINGGI
BAHAYA LISTRIK PADA TEGANGAN TINGGI / EKSTRA TINGGI
BAHAYA LISTRIK PADA INSTALASI TEGANGAN TINGGI / EKSTRA YANG PALING DOMINAN ADALAH GRADIEN TEGANGAN TINGGI ATAU TEGANGAN EKTRA TINGGI ITU SENDIRI TERHADAP MAHLUK HIDUP MAUPUN TERHADAP BENDA-BENDA LAIN YANG BERADA PADA DAERAH SEKITARNYA
SEBAGAI CONTOH SALURAN UDARA TEGANGAN TINGGI (SUTT) DIMANA SALURAN TENAGA LISTRIK YANG MENGGUNAKAN KAWAT TELANJANG (PENGHANTAR) DI UDARA BERTEGANGAN ANTARA 35 KV SAMPAI DENGAN 245 KV SESUAI STANDAR DI BIDANG KETENAGALISTRIKAN
SALURAN UDARA TEGANGAN EKSTRA TINGGI (SUTET) DIMANA SALURAN TENAGA LISTRIK YANG MENGGUNAKAN KAWAT TELANJANG (PENGHANTAR) DI UDARA BERTEGANGAN DI ATAS 245 KV SESUAI STANDAR DI BIDANG KETENAGALISTRIKAN
BAHAYA LISTRIK PADA TEGANGAN TINGGI / EKSTRA TINGGI
BAHAYA LISTRIK PADA INSTALASI TEGANGAN TINGGI / EKSTRA YANG PALING DOMINAN ADALAH GRADIEN TEGANGAN TINGGI ATAU TEGANGAN EKTRA TINGGI ITU SENDIRI TERHADAP MAHLUK HIDUP MAUPUN TERHADAP BENDA-BENDA LAIN YANG BERADA PADA DAERAH SEKITARNYA
SEBAGAI CONTOH SALURAN UDARA TEGANGAN TINGGI (SUTT) DIMANA SALURAN TENAGA LISTRIK YANG MENGGUNAKAN KAWAT TELANJANG (PENGHANTAR) DI UDARA BERTEGANGAN ANTARA 35 KV SAMPAI DENGAN 245 KV SESUAI STANDAR DI BIDANG KETENAGALISTRIKAN
SALURAN UDARA TEGANGAN EKSTRA TINGGI (SUTET) DIMANA SALURAN TENAGA LISTRIK YANG MENGGUNAKAN KAWAT TELANJANG (PENGHANTAR) DI UDARA BERTEGANGAN DI ATAS 245 KV SESUAI STANDAR DI BIDANG KETENAGALISTRIKAN
BAHAYA LISTRIK-28
Doc:Anton/03/04/ags
PADA SAAT INI LAHAN YANG TERSEDIA TERASA SEMAKIN SEMPIT KARENA PESATNYA PERKEMBANGAN DISEGALA BIDANG DEMIKIAN PULA PERTUMBUHAN PENDUDUK YANG CUKUP BESAR, SEHINGGA JALUR YANG DILALUI SUTT ATAU SUTET KEMUNGKINAN TIDAK DAPAT MENGHINDARI DAN TERPAKSA HARUS MELEWATI DAERAH DENGAN KEADAAN TERTENTU, SEPERTI DAERAH PEMUKIMAN YANG PADAT
BAHAYA LANGSUNG TERHADAP TEGANGAN TINGGI / EKSTRA TINGGI TERHADAP MANUSIA / MAHLUK HIDUP LAINNYA ADALAH SENGATAN LANGSUNG JIKA YANG BERSANGKUTAN BERSENTUHAN / MEMEGANG TEGANGAN TINGGI / EKTRA TINGGI, ATAUPUN TERKENA TEGANGAN SISA PADA INSTALASI TENAGA LISTRIK
UNTUK MENGANTISIPASI BAHAYA LISTRIK PADA TEGANGAN TINGGI / EKSTRA TINGGI TELAH DITETAPKAN ADANYA JARAK AMAN TERHADAP INSTALASI TEGANGAN TINGGI / EKSTRA TINGGI DIMAKSUD YANG DISEBUT RUANG BEBAS DAN RUANG AMAN TERUTAMA DISEKITAR SUTT / SUTET
PADA SAAT INI LAHAN YANG TERSEDIA TERASA SEMAKIN SEMPIT KARENA PESATNYA PERKEMBANGAN DISEGALA BIDANG DEMIKIAN PULA PERTUMBUHAN PENDUDUK YANG CUKUP BESAR, SEHINGGA JALUR YANG DILALUI SUTT ATAU SUTET KEMUNGKINAN TIDAK DAPAT MENGHINDARI DAN TERPAKSA HARUS MELEWATI DAERAH DENGAN KEADAAN TERTENTU, SEPERTI DAERAH PEMUKIMAN YANG PADAT
BAHAYA LANGSUNG TERHADAP TEGANGAN TINGGI / EKSTRA TINGGI TERHADAP MANUSIA / MAHLUK HIDUP LAINNYA ADALAH SENGATAN LANGSUNG JIKA YANG BERSANGKUTAN BERSENTUHAN / MEMEGANG TEGANGAN TINGGI / EKTRA TINGGI, ATAUPUN TERKENA TEGANGAN SISA PADA INSTALASI TENAGA LISTRIK
UNTUK MENGANTISIPASI BAHAYA LISTRIK PADA TEGANGAN TINGGI / EKSTRA TINGGI TELAH DITETAPKAN ADANYA JARAK AMAN TERHADAP INSTALASI TEGANGAN TINGGI / EKSTRA TINGGI DIMAKSUD YANG DISEBUT RUANG BEBAS DAN RUANG AMAN TERUTAMA DISEKITAR SUTT / SUTET
BAHAYA LISTRIK-29
Doc:Anton/03/04/ags
RUANG BEBAS
RUANG BEBAS ADALAH RUANG SEKELILING PENGHANTAR (KAWAT LISTRIK)
SUTT ATAU SUTET YANG BESARNYA TERGANTUNG TEGANGAN, TEKANAN
ANGIN DAN SUHU KAWAT PENGHANTAR
RUANG TERSEBUT HARUS DIBEBASKAN DARI ORANG MAHLUK HIDUP LAIN
MAUPUN BENDA APAPUN DEMI KESELAMATAN ORANG, MAHLUK DAN BENDA
LAIN TERSEBUT DEMIKIAN PULA KEAMANAN DARI SUTT ATAU SUTET ITU
SENDIRI
RUANG BEBAS
RUANG BEBAS ADALAH RUANG SEKELILING PENGHANTAR (KAWAT LISTRIK)
SUTT ATAU SUTET YANG BESARNYA TERGANTUNG TEGANGAN, TEKANAN
ANGIN DAN SUHU KAWAT PENGHANTAR
RUANG TERSEBUT HARUS DIBEBASKAN DARI ORANG MAHLUK HIDUP LAIN
MAUPUN BENDA APAPUN DEMI KESELAMATAN ORANG, MAHLUK DAN BENDA
LAIN TERSEBUT DEMIKIAN PULA KEAMANAN DARI SUTT ATAU SUTET ITU
SENDIRI
BAHAYA LISTRIK-30
Doc:Anton/03/04/ags
RUANG AMAN
RUANG AMAN ADALAH RUANG YANG BERADA DILUAR RUANG BEBAS YANG
TANAHNYA MASIH DAPAT DIMANFAATKAN
DALAM RUANG AMAN PENGARUH MEDAN LISTRIK DAN KUAT MEDAN MAKNET
SUDAH DIPERTIMBANGKAN DENGAN MENGACU KEPADA PERATURAN YANG
BERLAKU. UNTUK MENDIRIKAN BANGUNAN DI DALAM RUANG AMAN, TETAP
DIPERLUKAN IJIN MENDIRIKAN BANGUNAN (IMB) DARI PEMERINTAH DAERAH
RUANG AMAN
RUANG AMAN ADALAH RUANG YANG BERADA DILUAR RUANG BEBAS YANG
TANAHNYA MASIH DAPAT DIMANFAATKAN
DALAM RUANG AMAN PENGARUH MEDAN LISTRIK DAN KUAT MEDAN MAKNET
SUDAH DIPERTIMBANGKAN DENGAN MENGACU KEPADA PERATURAN YANG
BERLAKU. UNTUK MENDIRIKAN BANGUNAN DI DALAM RUANG AMAN, TETAP
DIPERLUKAN IJIN MENDIRIKAN BANGUNAN (IMB) DARI PEMERINTAH DAERAH
BAHAYA LISTRIK-31
Doc:Anton/03/04/ags
FAKTOR-FAKTOR YANG MEMPENGARUHI RUANG BEBAS DAN RUANG AMAN
• RUANG BEBAS DAN RUANG AMAN DAPAT DIATUR BESARNYA SESUAI
DENGAN KEBUTUHAN PADA SAAT MEMPERSIAPKAN RANCANG BANGUN
PADA SAAT MEMPERSIAPKAN RANCANG BANGUN TERSEBUT, RUANG AMAN
DAPAT DIPERLUAS DENGAN CARA MENINGGIKAAN MENARA DAN ATAU
MEMPERPENDEK JARAK ANTARA MENARA, SEHINGGA BILA ADA
PEMUKIMAN YANG AKAN DILINTASI SUTT ATAU SUTET YANG AKAN
DIBANGUN BERADA DIDALAM RUANG YANG AMAN
FAKTOR-FAKTOR YANG MENENTUKAN RUANG BEBAS DAN RUANG AMAN
ADALAH TEGANGAN KEKUATAN ANGIN DAN SUHU DISEKITAR PENGHANTAR
a. TEGANGAN
MAKIN BESAR TEGANGAN YANG BEKERJA PADA PENGHANTAR MAKIN
BESAR JARAK BEBAS MINIMUM (CLEARANCE) YAITU JARAK YANG
TERPENDEK DIIJINKAN ANTARA KAWAT PENGHANTAR DAN BENDA
ATAU KEGIATAN LAIN SESUAI DENGAN ANGKA-ANGKA YANG TERTERA
PADA TABEL V-I
FAKTOR-FAKTOR YANG MEMPENGARUHI RUANG BEBAS DAN RUANG AMAN
• RUANG BEBAS DAN RUANG AMAN DAPAT DIATUR BESARNYA SESUAI
DENGAN KEBUTUHAN PADA SAAT MEMPERSIAPKAN RANCANG BANGUN
PADA SAAT MEMPERSIAPKAN RANCANG BANGUN TERSEBUT, RUANG AMAN
DAPAT DIPERLUAS DENGAN CARA MENINGGIKAAN MENARA DAN ATAU
MEMPERPENDEK JARAK ANTARA MENARA, SEHINGGA BILA ADA
PEMUKIMAN YANG AKAN DILINTASI SUTT ATAU SUTET YANG AKAN
DIBANGUN BERADA DIDALAM RUANG YANG AMAN
FAKTOR-FAKTOR YANG MENENTUKAN RUANG BEBAS DAN RUANG AMAN
ADALAH TEGANGAN KEKUATAN ANGIN DAN SUHU DISEKITAR PENGHANTAR
a. TEGANGAN
MAKIN BESAR TEGANGAN YANG BEKERJA PADA PENGHANTAR MAKIN
BESAR JARAK BEBAS MINIMUM (CLEARANCE) YAITU JARAK YANG
TERPENDEK DIIJINKAN ANTARA KAWAT PENGHANTAR DAN BENDA
ATAU KEGIATAN LAIN SESUAI DENGAN ANGKA-ANGKA YANG TERTERA
PADA TABEL V-I
BAHAYA LISTRIK-32
Doc:Anton/03/04/ags
TABEL V-I
JARAK BEBAS MINIMUM ANTARA PENGHANTARSUTT DAN SUTET DENGAN TANAH DAN BENDA LAIN
TABEL V-I
JARAK BEBAS MINIMUM ANTARA PENGHANTARSUTT DAN SUTET DENGAN TANAH DAN BENDA LAIN
SUTT SUTET 500 KV
NO. LOKASI 66 KVM
150 KVM
SIRKITGANDA
M
SIRKITTUNGGAL
M
1.2.
LAPANGAN TERBUKA ATAU DAERAH TERBUKADAERAH DENGAN KEADAAN TERTENTU :2.1. BANGUNAN TIDAK TAHAN API2.2. BANGUNAN TAHAN API2.3. LALU LINTAS JALAN / JALAN RAYA2.4. POHON-POHON PADA UMUMNYA, HUTAN, PERKEBUNAN2.5. LAPANGAN OLAH RAGA2.6. SUTT LAINNYA, PENGHANTAR UDARA TEGANGAN
RENDAH, JARINGAN TELEKOMUNIKASI, ANTENA RADIO,ANTENA TELEVISI DAN KERETA GANTUNG
2.7. REL KERETA BIASA2.8. JEMBATAN BESI, RANGKA BESI PENAHAN PENGHANTAR,
KARENA LISTRIK TERDEKAT DAN SEBAGAINYA2.9. TITIK TERTEINGGI TIANG KAPAL PADA KEDUDUKAN AIR
PASANG / TERTINGGI PADA LALU LINTAS AIR
6.5
12.53.58
3.512.5
3
83
3
7.5
13.54.59
4.513.5
4
94
4
10
148.5158.5148.5
158.5
8.5
11
158.5158.5158.5
158.5
8.5
BAHAYA LISTRIK-33
Doc:Anton/03/04/ags
b. ANGIN
MAKIN BESAR TEKANAN ANGIN, MAKIN BESAR AYUNAN KAWAT PENGHANTAR KE KIRI ATAU KE KANAN, PADA SUATU GAWANG (JARAK ANTARA DUA MENARA) AYUNAN YANG TERBESAR KARENA PENGARUH ANGIN ADALAH PADA KAWAT PENGHANTAR YANG LENGKUNGANNYA PALING RENDAH SEDANGKAN AYUNAN SEMAKIN KECIL KE ARAH MENARA
c. SUHU KAWAT PENGHANTAR
MAKIN BESAR SUHU YANG MEMPENGARUHI KAWAT PENGHANTAR MAKIN MENGENDOR KAWAT PENGHANTAR TERSEBUT, SEHINGGA ANDONGANNYA MENJADI LEBIH BESAR, HAL INI SUDAH DIPERHITUNGKAN PADA SAAT MENDESAIN SUTT ATAU SUTET TERSEBUT
KENAIKAN SUHU TERSEBUT DISEBABKAN OLEH SUHU DISEKELILING DAN SUHU YANG DIAKIBATKAN OLEH BESARNYA ARUS YANG MENGALIR PADA KAWAT PENGHANTAR
b. ANGIN
MAKIN BESAR TEKANAN ANGIN, MAKIN BESAR AYUNAN KAWAT PENGHANTAR KE KIRI ATAU KE KANAN, PADA SUATU GAWANG (JARAK ANTARA DUA MENARA) AYUNAN YANG TERBESAR KARENA PENGARUH ANGIN ADALAH PADA KAWAT PENGHANTAR YANG LENGKUNGANNYA PALING RENDAH SEDANGKAN AYUNAN SEMAKIN KECIL KE ARAH MENARA
c. SUHU KAWAT PENGHANTAR
MAKIN BESAR SUHU YANG MEMPENGARUHI KAWAT PENGHANTAR MAKIN MENGENDOR KAWAT PENGHANTAR TERSEBUT, SEHINGGA ANDONGANNYA MENJADI LEBIH BESAR, HAL INI SUDAH DIPERHITUNGKAN PADA SAAT MENDESAIN SUTT ATAU SUTET TERSEBUT
KENAIKAN SUHU TERSEBUT DISEBABKAN OLEH SUHU DISEKELILING DAN SUHU YANG DIAKIBATKAN OLEH BESARNYA ARUS YANG MENGALIR PADA KAWAT PENGHANTAR
BAHAYA LISTRIK-34
Doc:Anton/03/04/ags
BAHAYA LISTRIK-35
Doc:Anton/03/04/ags
BAHAYA LISTRIK-36
Doc:Anton/03/04/ags
BAHAYA LISTRIK-37
Doc:Anton/03/04/ags