Bagaimana memulai konversi lampu konvensional ke LED Dialight

Click here to load reader

  • date post

    20-Mar-2017
  • Category

    Environment

  • view

    134
  • download

    5

Embed Size (px)

Transcript of Bagaimana memulai konversi lampu konvensional ke LED Dialight

  • Cara Mudah Konversi Lampu

    Konvensional ke LED Dialight

    Oil and Gas

  • LED for Pertamina Balongan 2

    Executive Summary

    Kasus di halaman berikut merupakan hal yang biasa terjadi di Industri Oiland Gas, berdasarkan data lampu existing yang terdapat di lokasi NPU,POC, dan OSBL pada Pertamina Unit Pengolahan VI Balongan, saat initotal konsumsi listrik berdasarkan system watt: 314. 435 Watt (terdirilampu PJU, Floodlights, High Bay dan T8/TL) .

    Jika konversi ke LED Lighting diterapkan maka akan di perolehpenghematan (energy saving) sebesar 178.546 Watt, sehingga totalkonsumsi hanya 135.889 Watt, artinya ada penurunan sebesar 56,78%dengan lelebihan sebagai berikut, usia lampu up to 100K hours, fullperformance warranty 5 tahun untuk Area Light, 7 Tahun untuk lampuPJU, 10 tahun untuk LED highbay dan Floodlights merk Dialight.

    Selama masa warranty LED Dialight artinya tidak ada belanja lampu (freemaintenances), disamping keunggulan lainnya yang di miliki LED Dialight.

  • 3

    DialightStreetlight: MV-400W = 99 Units

    PN: SL3C5RLGG

    StreetSense Streetlight, Type III, 16,000

    lumens, 190 Watts, 120-277V AC, Cool

    White, Gray, Glass lens, 10kV Surge

    Protection, Shorting Cap

    Mercury Vapor 400 Watt (480

    watt system) 99 units = 47.520

    watt

    Dialight Streetlight 190 Watt 99

    units = 18.810 wattEnergy Saving:

    28.710 WattHazardous Locations:

    PN: SLA3N4SG

    ATEX Zone 2, Type III, Neutral White, 120-

    277VAC, 6kV Surge Protection, 250W,

    Glass lens

  • 4

    DialightFloodlight: MV-400W = 68 Units

    Hazardous Locations:PN: FLD422NC4NG SafeSite

    Flood Light 13500 lumens, 140

    Watts, 100-277V, Cool White,

    Narrow (23),Clear Tempered Glass lens, [CID2]

    Non Hazardous

    Locations:

    PN: FLW467NC4NG

    DuroSite Flood Light

    14750 lumens, 140 Watts,

    100-277V, Cool White,

    Asymmetrical (115 x 140)Clear Tempered Glass lens

    Mercury Vapor 400 Watt

    (480 watt system) 68 units

    = 32.640 wattDialight

    Floodlight 140

    Watt 68 units =

    9.520 watt

    Energy Saving: 23.120 Watt

  • 5

    DialightHigh Bay: MV-400W = 145 Units

    Mercury Vapor 400 Watt

    (480 watt system) 145

    units = 69.600 watt

    Non Hazardous

    Locations:

    PN: HEGMC4KN-SNG

    Vigilant High Bay

    18000 lumens, 144

    Watts, 100-277V AC,

    Cool White, Clear

    Tempered Glass lens

    Hazardous

    Locations:

    SafeSite High Bay,

    Circular, 18000

    lumens, 144 Watts,

    100-277V AC, Cool

    White, Clear

    Tempered Glass

    lens, [CID2, CIID2]

    Dialight High Bay, 144

    Watt, 145 Units= 20.880

    Energy Saving: 48.780

    Watt

  • 6

    DialightHigh Bay: MV-250W = 37 Units

    Mercury Vapor 250 Watt

    (295 watt system) 37 units

    =10.915 watt

    Non Hazardous

    Locations:

    PN: HEGMC4KN-SNG

    Vigilant High Bay

    18000 lumens, 144

    Watts, 100-277V AC,

    Cool White, Clear

    Tempered Glass lens

    Hazardous

    Locations:

    SafeSite High Bay,

    Circular, 18000

    lumens, 144 Watts,

    100-277V AC, Cool

    White, Clear

    Tempered Glass

    lens, [CID2, CIID2]

    Dialight High Bay, 144

    Watt, 37Units= 5.328

    Energy Saving: 5.587 Watt

  • 7

    DialightTL 2X36W = 1357 Fixture, TL 2x18W= 1110 (4934 T8)

    Energy Saving: 72.349 Watt

    PN: LPM3C4D2P

    DuroSite Linear - Gen II, ,

    3500 lumens, 33 Watts, 100-

    277V AC, Cool White, Clear

    Polycarbonate lens, Low

    Profile

    TL 2x36 Watt (80 system

    Watt), 1367 Units= 109.360

    watt

    Dialight Linear, 33 Watt,

    2467 Units= 81.411 Watt

    TL 2x18 Watt (40 system

    Watt), 1110 Units= 44.400

    watt

  • 8

    DialightExisting Lamps

    Crouse-Hinds

    VMVS250

    Wattage: 250

    Change to Area Light, PN: HZD9C2NC

    70 Watt

  • 9

    Dialight

  • 10

    DialightHZD Area Light with Retrofit Adapter Kit

  • 11

    DialightEase Of Retrofitting

    Unscrew to access wiring compartment,

    disconnect the live, neutral & ground wires.

    Step 1

    Ready to change

  • 12

    DialightEase Of Retrofitting

    Lift HID fixture from the hinge

    hinge.

    New LED fixture with integrated

    adaptor and wiring compartment

    hinged to original bracket.

    Step 2

    Step 3

  • 13

    DialightEase Of Retrofitting

    Dialight LED fixture retrofitted to

    original bracket.

    Captive screw

    Step 4

    Retrofit complete. Turn On

  • 14

    Dialight

    Cross Reference Guide to Convert to Dialight LED

    Hazardous Locations ((Metal Halide or HPS)

  • 15

    Dialight

  • 16

    Dialight

    Cross Reference Guide to to Dialight LED on

    Non Hazardous Locations (Metal Halide or HPS)

  • 17

    Dialight

  • 18

    Dialight

  • 19

    Dialight

  • Dialight has the largest installed

    base of LED fittings in the world.

    500,000 High Bays have been sold globally since 2008

    750,000 total fittings have been sold globally since 2008

    +

    As of March 2016

  • 21

    Dialight

    788,111 tonnesof Carbon Dioxide Equivalent

  • 22

    Dialight

    788,111 tonnesis equivalent to greenhouse gas emissions from:

    165,918 passenger vehicles driven for one year

    3019861304 km driven by an average passenger vehicle

    282,477 tonnes of waste sent to the landfill

  • 23

    Dialight

    335695389 litres of petrol consumed

    10,433 tanker trucks worth of petrol

    1,832,816 barrels of oil consumed

    788,111 tonnesis equivalent to CO2 emissions from:

  • 24

    Dialight

    383975453 kg of coal burned

    4,226 railcars worth of coal burned

    788,111 tonnesis equivalent to CO2 emissions from:

  • 25

    Dialight

    788,111 tonnesis equivalent to CO2 emissions from:

    71,908 homes energy use for one year

    32,837,959 propane cylinders used for home barbeques

    108,406 homes electricity use for one year

  • 26

    Dialight

    217 wind turbines installed

    20,614,989 incandescent lamps switches to CFLs

    788,111 tonnesis equivalent to CO2 emissions from:

  • 27

    Dialight

    20,207,975 tree seedlings grown for 10 years

    261424 hectares of U.S. forests in one year

    2462 hectares of U.S. forests preserved from conversion

    to cropland in one year

    788,111 tonnesis equivalent to carbon sequestered by:

  • www.epa.gov/energy/greenhouse-gas-equivalencies-calculator

    Based on data from 2008 - 2015

  • 29

    DialightSINGAPORE

    Afton Chemical

    Cameron Drilling

    Chevron Philips

    Chevron Oronite

    Croda Singapore Pte Ltd

    DSTA Defense Science & Technology Agency

    ExxonMobil Refinery

    ExxonMobil Chemicals

    Evonik Industries

    Lanxess Butyl Rubber

    Lanxess Nd-PBR

    Petrochemical Corp Singapore

    Shell Eastern MEG

    Singapore Refining Company

    The Polyolefin Company

    Glaxo Smith Kline

    Merck, Sharpe & Dohme

    Roche

    Schering Plough

    Horizon Terminal

    Stepan Asia Pte Ltd

    Stolthaven Terminal

    OFFSHORE

    Bumi Armada Claire FPSO

    Diamond Offshore Ocean Patriot

    Diamond Offshore Ocean America

    ENSCO Rig 67 Drilling Rig

    M3nergy Bukit Tua FPSO

    Northern Offshore Drilling Rig

    Pertamina PHE Boss1 MOPU

    Santos Ltd Inlet CIP Stage 2

    Shelf Drilling Randolph Yost

    Talisman Paragon L785 Rig

    Transocean Deepwater Trident 2

    Transocean Deepwater Millennium

    Transocean GSF Explorer

    Transocean MG Hulme

    Transocean Polar Pioneer

    SINGAPORE (contd)

    Vopak Terminal Penjuru

    Vopak Terminal Chang Chun

    PUB Lorong Halus

    SSMC Silicon Manufacturing

    Yahoo Data Center

    INDONESIA

    Badak LNG Indonesia

    Binakarindo

    Chevron Pacific Indonesia

    Conoco Philips Indonesia

    Freeport Mining Indonesia

    Gajah Tunggal

    Ispat Indo Steel

    Nestle Indonesia

    Mulia Glass

    Pertamina Dumai Refinery

    Pertamina EP Exploration

    Pertamina Hulu Energi (PHE ONWJ)

    Pertamina SPBG CNG Daan Mogot

    Perusahaan Gas Negara ( PGN )

    Petrosea excavators

    PLN Tanjung Jati Power Plant

    Pupuk Kujang

    Star Energy ( KAKAP) LTD

    Trans Pacific Indonesia ( TPPI )

    Customers - Asia Pacific

  • 30

    DialightMALAYSIA

    ABF Fertilizer Bintulu

    BASF Petronas Chemicals

    BP Petronas Acetyls

    Carigali HESS Cakarawala Platform

    Darien Chemical

    Dove Chem Sdn Bhd

    Esso Malaysia Bhd

    Flexsys Chemicals

    Kaneka Gebeng

    Kimberly Clark

    Malay Sino Chemical Industries

    Mitsui Copper Foil

    MTBE-PDH

    MTBE-Polypropylene

    Murphy Oil

    Petrofac Cendor Wellhead Platforms

    Petronas BP Chemicals

    Petronas CUF Gebeng

    Petronas Dagangan (Prai, Melaka, Kertih)

    Petronas Fertilizer Kedah ( PFK )

    Petronas Optimal Chemicals

    Petronas Penapisan Kertih

    MALAYSIA (contd)

    Petronas Carigali BNJT, BJOP Platforms

    Petronas Carigali Terminal (TCOT)

    Polyplastics Asia

    Sapura Kencana

    Saint Gobain

    SCA Hygiene

    Shell Tank Farm Labuan

    Synthese

    Synthomer Sdn Bhd

    Tanjung Bin Power Plant

    Talisman Energy Malaysia

    Tenaga Nasional B